Ramon E. Nugent, P.E. Acentech Inc.
Transcription
Ramon E. Nugent, P.E. Acentech Inc.
Ramon E. Nugent, P.E. Acentech Inc. TRB ADC40 Conference Because of the sensitive nature of the unresolved issues related to the project, the preparers of the EIR/EIS noise and vibration study, the Contractor, the Contractor’s noise and vibration consultant, and the Owner of the LRT line, the name of the LRT line will not be identified. TRB ADC40 Conference Please do not speculate or ask. Background Our Role Measurement Measurement Measurement Measurement Status TRB ADC40 Conference System Procedure Results – Noise Results – Vibration 8.6 miles of double track 10 new stations Existing noise and vibration measurements in 2000 and supplemented in 2004 Final noise and vibration report in 2005 Environmental documents approved in 2006 Construction 2006 to 2012 Powered electrically with overhead catenary wires TRB ADC40 Conference Used measurements of existing Siemens Transportation Systems P2000 Assumed: three-car trains from 06:-09: and 15: to 19: ◦ one-car trains 05: to 06: and 21: to 01: ◦ two-car trains remainder of day Assumed Lmax (1 dBA less than FTA Recommendation): ◦ 77 dBA at 40 mph ◦ 78.4 dBA at 55 mph Headways: ◦ Peak hours = 5 minutes ◦ Off-peak hours = 12 minutes TRB ADC40 Conference Forced density measurements of existing Siemens Transportation Systems P2000 at 40 mph Transfer mobility measurements Calculated Maximum Vibration Levels at 55 mph speed using above plus an Unknown safety factor Possible impacts projected within approximately 140 ft Identified Noise Impacts Moderate Identified Vibration Impacts Severe Severe SF MF SF MF SF MF 60 6 49 0 150 23 Noise Noise Barriers ◦ 2710 feet 8-ft ◦ 5940 feet 6-ft ◦ 760 feet of 4-ft on elevated structure Reduce crossing bells to 60 dBA at 50 ft Sound insulate Homes TRB ADC40 Conference Vibration 7,300 feet of track mitigation Spring-rail or movable point frog at crossovers Relocating crossovers “No residual impacts” “all noise and vibration impacts have been mitigated to levels that meet FTA noise and vibration impact criteria.” TRB ADC40 Conference Provide an Independent noise and vibration evaluation ◦ Measure noise emissions ◦ Calculate full service Ldn at noise sensitive receivers along ROW ◦ Measure maximum vibration levels of LRT ◦ Quantify the potential of residual noise and vibration impacts ◦ Do it quickly TRB ADC40 Conference Real Time Analyzers ◦ 1-second RMS Time History Vibration sensor attached to ground stake ◦ 50 mV/G sensitivity Microphones ◦ ½” microphone ◦ Windscreens Calibrated using NIST traceable standards TRB ADC40 Conference Take advantage of LRT operator training ◦ Actual trains ◦ Actual speeds Selected 19 residential locations along ROW where impacts were identified and mitigation had been installed Measure maximum ground-borne Vibration Measure SEL at two heights ◦ First story elevation ◦ Second story elevation Collect representative sample (5 pass-bys in each direction) TRB ADC40 Conference TRB ADC40 Conference TRB ADC40 Conference TRB ADC40 Conference TRB ADC40 Conference Acentech Report submitted to Contractor Grand opening occurred in late April Ridership has been a success Contractor still finishing punch list Waiting for meeting to discuss noise & vibration issues ◦ Expect discussions to begin in August TRB ADC40 Conference TRB ADC40 Conference