ZEXIA1503-05 - FUJITEC Global Website
Transcription
ZEXIA1503-05 - FUJITEC Global Website
ISO9001 ISO14001 OHSAS18001 CAUTION: The product images/pictures in this product catalog are conceptual renderings that do not fully reflect actual colors and detailed parts. Therefore, this catalog cannot be used as a basis for a contract or negotiations. ZEXIA1503-05 PRODUCT CONCEPT Global Fujitec, Creating and Leading the New Standard for Elevators. Delivering safe and reliable elevators to the world. Trusted by people all over the world. 1 For our new global standard elevator, Fujitec has standardized elevator main components, such as traction machine, control system and aesthetic fixtures, as Global Common Components. Thus establishing the Fujitec brand identity and creating an integrated global quality management system and product reliability for our global supply chain. 2 DYNAMICS INTELLIGENCE HUMANITY The permanent magnet synchronous gearless traction machine designed by Fujitec realizes the best balance between dynamic performance and reliability. Fujitec accumulated its know-how expertise throughout the design to production process. Our products meet various space-saving layout requirements. Fujitec’s fully self-manufactured control system, ranging from control-circuit to inverter, establishes a highly reliable elevator performance. At anytime, we can provide prompt support that will improve operating efficiency. A new universal design provides higher visibility, usability and passenger comfort. Simple but elegant, our new design offers congenial space for all passengers. 3 4 DYNAMICS INTELLIGENCE Green Enhanced Safety Permanent Magnet Gearless Traction Machine The new Permanent Magnet (PM) synchronous gearless drive system does not require a speed-reducing mechanism which eliminates the use of polluting lubricating oil in a conventional gear box. Thereby establishing a new age of elevators for green functionality and eco-friendliness. By upgrading various elevator safety mechanisms, safety is further enhanced. The design philosophy of the Fujitec Group is fully applied in order to ensure passenger safety to the highest extent. Noise in the machine room is substantially reduced because no noise is generated by the gear when the motor is running at high speeds. Car Door Opening Protection Device Small Machine Room = Space Saving This safety device prevents the car door from opening in a non-locking area, which protects passengers from falling into the hoistway. Compared with conventional machine room elevators, our small machine room requires 60% less area. A substantial area reduction of 60% Reliable Driving System Design Impact Resistant Landing Door System Power Conventional Machine 827kWh/month PM Gearless Machine 646kWh/month Motor Capacity Conventional Machine 9.0kW PM Gearless Machine 8.5kW 22% Data for Monthly※ Electrical Usage 600 Operations Per Day ※One month shall be 30 days. Travel Distance: 30meters Rated Speed: 1.0mps Rated Load: 1200kg Ultra-Slim The landing doors are further strengthened to be more impact resistant, which effectively protects passengers from falling into the hoistway in the event of an accidental impact with the landing doors. Depending on actual conditions, application and calculation results will vary. Permanent Magnet Gearless Door Operator Distributed Control System Fujitec's new ultra-slim PM door operator employs Fujitec's highly-developed transmission mechanism which uses a PM motor as the driving device. Compared with conventional motor driving door operators, around 35% reduction in energy usage is achieved. With multiple security settings, the adoption of a terminal holding device provides more stable, smooth opening and closing actions, ensuring safe elevator operation. In addition, the ultra-slim design saves hoistway space. Energy usage reduced by around 5 35% Serial communication is adopted between the control panel (32-bit), hall-call buttons, floor indicators and hall lanterns. UCMP (Unintended Car Movement Protection System) The Unintended Car Movement Protection System (UCMP) can immobilize the car when the elevator landing and car doors are opened but the car is not aligned correctly with the landing floor. This protects against personal injury and equipment damage. COP: Control Panel COB: Car Operating Board IN: Hall Indicator MIC: Microcomputer Depending on content and quantity of data, multiple protocol is respectively used, which achieves high-speed and large-scale data communications at 10 times the rate when compared to conventional systems. As a result, the capability of monitoring elevator running status and instructions, with respect to communication speed, precision, reliability, has been greatly enhanced. The “BUS LINE mode”, advanced in the industry, is employed for communication, with strong anti-interference capabilities and multiple system expansion options. than the conventional. Instructions for conventional elevators are transmitted from the control panel in the machine room to respective devices through the traveling cable. Fujitec's "distributed control system" will exert the advantage of its security much better, the respective functions will be implemented strictly through the correct command received, so the elevator will obtain the absolute security. 6 HUMANITY Intelligent·Clean Human Engineering The new Fujitec's global standard design is applied for button and font. This is human engineering, a combination of better visibility and improved human-machine interface. VONIC Automatic Voice Announcement System (Optional) The automatic voice announcement system is used for broadcasting elevator direction, arrival floor, door actions, emergency instructions and other information. IONFUL PlasmaclusterTM Ion Generating System New Standard Font 23569 Former Standard Font 23569 Fujitec embraces the PlasmaclusterTM technology of Sharp Corporation, and takes the lead in utilizing the PlasmaclusterTM Ion Generating System (IONFUL) in the elevator industry. It is highly effective in eliminating airborne mold, germs, bacteria, allergens, and bad odors. Ventilation Unit Plasmacluster Ion Generating Device Ventilation Opening Ventilation System Fan Plasmacluster The new button design has a more distinct font than in previous generations, which is more recognizable in various lighting conditions and viewing positions. This unique design further improves the human-machine interface. A high contrast green color is applied to the door open button, so as to greatly reduce humanerror in pressing the incorrect button. Plasmacluster Ion Generating Device PlasmaclusterTM is a trademark of Sharp Corporation Plasmacluster Ion Safety·Green Intelligent Multi-Beam Self-Diagnostic Night Operation LED Ceiling Lights (Optional) The intelligent multi-beam system The self-diagnostic operation is LED energy-saving ceiling lights is able to effectively detect humans, the most characteristic feature of were adopted early in the industry, so pets, and objects to ensure passenger Fujitec products. Every night, the as to realize green functionality and safety when entering or leaving the elevator self-diagnostic operation environmental protection. elevator. The protection system automatically starts to inspect is designed to project an infrared elevator operation and braking ray-light curtain covering the whole system at each floor to ensure door opening height at the elevator passenger safety. entrance, and if any light beam is interrupted, the closing door will stop closing and re-open automatically. Life Filament Lamp Approx. 1,500h Wattage 90W Equal Conditions Approx. 13 times LED Approx. 1/10 9W Approx. 20,000h The emergency call button is located about 900mm from floor level allowing children and disabled persons to use in case of emergency. 7 8 Standard Car Design Standard Car Design Stylish Design, Stylish Life Our elevator cabin is reborn with a new design concept, the "Accent Stripe." This vertical running stripe divides the interior car panels to create a sharp contrast and stylish atmosphere in the cabin. ZE-S1 Wall & Transom CR-b3 Painted Steel Sheet (TE-b2) Accent Stripe in left, right and rear car panels Metallic Paint Finish(TE-f2) Door Painted Steel Sheet (TE-b2) Floor BD-b2 ZE-S2 Ceiling CE-g2 Painted Steel Sheet (TE-a7) Wall & Transom CR-b1 Painted Steel Sheet (TE-a7) Accent Stripe in left, right and rear car panels Painted Steel Sheet(TE-a9) Door Painted Steel Sheet (TE-a7) Ceiling CE-g2 Painted Steel Sheet (TE-b2) Floor(Selection) (Vinyl Tile) Standard Car Design ZE-S4 Ceiling CE-g2 Painted Steel Sheet (TE-a7) Floor BD-b1 Sill Stainless Steel Wall & Transom CR-c1 Painted Steel Sheet (TE-a7) Accent Stripe in Left, Right and Rear Car Panel Stainless Steel with Mirror Finish Fan Cross-flow Fan & IONFUL Car Internal Height 2350mm Car Panel Height 2350mm ZE-S3 Ceiling CE-g2 Painted Steel Sheet (TE-b1) Wall & Transom CR-b2 Painted Steel Sheet (TE-b1) Accent Stripe in Left, Right and Rear Car Panel Metallic Paint Finish(TE-f1) Door Painted Steel Sheet (TE-b1) Door Painted Steel Sheet (TE-a7) Floor BD-b3 Sill Stainless Steel Floor BD-b1 Sill Stainless Steel Fan Cross-flow Fan & IONFUL Car Internal Height 2350mm Car Panel Height 2350mm ZE-S5\S6\S7 Ceiling CE-g2 Painted Steel Sheet (TE-a7\ TE-b1\ TE-b2) Fan Cross-flow Fan & IONFUL Car Internal Height 2350mm Wall & Transom CR-b6\b7\b8 Painted Steel Sheet (TE-a7\ TE-b1\ TE-b2) Accent Stripe in Left, Right and Rear Car Panel Painted Steel Sheet Car Panel Height 2350mm (TE-a7\ TE-b1\ TE-b2) Door Painted Steel Sheet (TE-a7\ TE-b1\ TE-b2) Floor BD-b6\ BD-b4\ BD-b5 Sill Stainless Steel Fan Cross-flow Fan & IONFUL Car Internal Height 2350mm Car Panel Height 2350mm BD-b1 BD-b2 BD-b3 Sill Stainless Steel Fan Cross-flow Fan & IONFUL Car Operating Board FX-g1 BD-b4 Car Internal Height 2350mm Car Panel Height 2350mm BD-b5 Note 1: ZE-S5\ S6\ S7 respectively correspond to TE-a7、TE-b1、TE-b2 and BD-b6、BD-b4、 BD-b5. Note 2: The above is the image of ZE-S7. Note 3: For a wide car and 1200kg & 1350kg capacity cars, the rear panel will be divided into five blocks. BD-b6 9 10 11 Optional Car Design Optional Car Design ZE-X2 ZE-X3 ZE-X4 ZE-X5 ZE-X1 Ceiling CE-g2 Metallic Paint Finish (TE-f1) Wall & Transom Stainless Steel with Hairline Finish Accent Stripe in Left, Right and Rear Car Panel Stainless Steel with Hairline Finish Door Stainless Steel with Hairline Finish Floor BD-b6 Sill Stainless Steel Ceiling CE-g2 Titanium-Black Coated Stainless Steel with Mirror Finish Wall & Door & Transom Laminated Steel Sheet(W-205) Accent Stripe in Left, Right and Rear Car Panell Stainless Steel with Mirror Finish Ceiling Standard Design Floor Medallion & Plastic Flooring Sill Stainless Steel Fan Cross-flow Fan & IONFUL Car Internal Height 2350mm Car Panel Height 2350mm CE-g2 Ceiling CE-c1 Painted Steel Sheet(TE-a7) Wall & Door & Transom Painted Steel Sheet (TE-a7) Accent Stripe in Left, Right and Rear Car Panel Titanium-Gold Coated & Etched Stainless Steel with Mirror Finish(YS-059) Ceiling Optional Design Floor Medallion & Plastic Flooring Sill Stainless Steel Fan Cross-flow Fan & IONFUL Car Internal Height 2425mm Car Panel Height 2600mm CE-c1 Ceiling CE-c2 Metallic Paint Finish(TE-f1) Wall & Door & Transom Metallic Paint Finish(TE-f2) Accent Stripe in Left and Right Car Panel Stainless Steel with Sandblast Finish Accent Stripe in Rear Car Panel Metallic Paint Finish(TE-f2) Half Mirror with SUS-HL Frame (Mirror by Others) Floor Medallion & Plastic Flooring Sill Stainless Steel Fan Cross-flow Fan & IONFUL Car Internal Height 2445mm Car Panel Height 2600mm CE-c2 Ceiling CE-c3 Painted Steel Sheet(TE-b1) Floor Medallion & Plastic Flooring Wall & Door & Transom Etched Stainless Steel with Mirror Finish(YS-015) Accent Stripe in Left, Right and Rear Car Panel Stainless Steel with Mirror Finish Fan Cross-flow Fan & IONFUL Sill Stainless Steel Car Internal Height 2480mm Car Panel Height 2600mm CE-c3 Fan Cross-flow Fan & IONFUL Car Operating Board FX-g1 Car Internal Height 2350mm Car Panel Height 2350mm Painted Steel Sheet (Standard), Light Bulb Painted Steel Sheet (Standard), Milky White Resin Shade, Fluorescent Lamp, Light Bulb Painted Steel Sheet (Standard), Milky White Resin Shade, Fluorescent Lamp Painted Steel Sheet (Standard), Milky White Resin Shade, Fluorescent Lamp Note 1: When Design Style 02, 03 and 04 are selected, the overhead height (OH) is increased by 250mm. Note 2: Car internal heights will vary according to ceiling types. For details, please contact our sales team. 12 13 14 Standard Fixtures Optional Fixtures Floor Indicator : Large and bright orange LED dot-matrix clearly indicates the car location even at a glance. Moving arrow indicator is synchronized with car acceleration, deceleration and traveling speeds and it relays real-time operation status to passengers. Capacity Plate: Indicates Maximum Capacity Interphone: Passengers can communicate with the machine room and the security room in case of emergency. FX-c1 FX-g4 FX-g1 FX-c41 FX-c51 FX-c4 FX-c5 Hall Indicator: Bright orange LED clearly indicates car operation status. Moving arrow indicator shows real-time operation status. Polycarbonate Face Plate: The face plate is tough (3H Surface Hardness), flame retardant, and impact resistant. The surface has an antiaging and a lustrous silver metallic finish. FX-g11 Landing Call Button (Optional) Floor Indicator: Color LCD Screen FX-g5 Floor Selection Button: The button rim of the selected floor lights up in orange for easy recognition and confirmation. FX-g6 Large Door Open Button: The enlarged and high contrasted green button is more noticeable and avoids human error providing better human-machine interface. Emergency Call Button: In case of emergency, pressing the yellow button will immediately alert the security room and machine room of an emergency situation. The interphone is also activated by this button. FX-c7 FX-c72 FX-c6 FX-g7 FX-g8 Service Console: Operation control and other switches are located in the console box. The console can be opened by authorized personnel with a special key. FX-c71 Spec Face Plate Indicator Button Standard Spec Resin & Polycarbonate (Wall Mounted Type) Orange Dot-Matrix LED Micro Touch Button CP-C1(Resin) Spec Face Plate Indicator Button 15 Optional Spec Stainless Steel with Hairline Finish (Box Type) Orange Dot-Matrix LED:FX-c1,FX-c4,FX-c5,FX-c7,FX-c71 Monochrome LCD Screen:FX-c41,FX-c51,FX-c72 Micro Touch Button CP-D1(Stainless Steel) 16 Optional Fixtures Optional Fixtures FX-b11 FX-b5 FX-b4 FX-f1 FX-f4 FX-f5 FX-f41 FX-f51 Floor Indicator: Color LCD Screen FX-b1 FX-b71 FX-b7 FX-b8 FX-b6 FX-f71 FX-f61 FX-f41,FX-f51、FX-f61、FX-f71:Wall Mounted Type; FX-f4、FX-f5 :Box Type Spec Face Plate Indicator Button 17 Optional Spec Stainless Steel with Mirror and Sandblast Finish (Box Type) Orange Dot-Matrix LED Micro Touch Button CP-C2(Stainless Steel) Spec Face Plate Indicator Button Optional Spec Resin & Metal Surface(Wall Mounted Type/Box Type) Orange Dot-Matrix LED Micro Touch Button CP-D1(Stainless Steel) 18 Landing Design Color Chart The Expert in Control Systems, Providing Solutions Superb Craftsmanship & Smooth Texture Our advanced control system will meet the various demands from customers for group control system under various building requirements. Robustness, using high-corrosion resistant electro-galvanized steel sheet used as a base material, and comfort, using powder coating finish to provide vibrant and sharp visual effects, are balanced. TE-a9 Ceiling, Car Panel, Car Door, Landing Door, Jamb TE-a7 Note:TE-f1 and TE-f2 uses sprayed metallic paint which are not applicable to the landing door and jamb. TE-f1 TE-b1 TE-f2 TE-b2 1 Car 2 Car YS-001 YS-004 YS-007 YS-008 YS-015 YS-025 YS-026 YS-059 BD-b1 BD-b2 BD-b3 BD-b4 BD-b5 BD-b6 Car Panel, Car Door and Landing Door (Stainless Steel with Etching) Car Floor(Vinyl Tile) The above computer generated colors may differ from actual colors. Group Supervisory Control 19 Please confirm the color with an actual color sample. 20 Functions OPERATION SYSTEM Driving System PM Synchronous Gearless Traction Machine. Floor Height SelfLearning The elevator has a self-learning mechanism that detects each floor height precisely in order to realize the accurate leveling. Starting Torque Compensation Compensation torque is applied before elevator operation to ensure passenger comfort while the elevator is starting to move. SERVICE FUNCTIONS Automatic Return to Main Floor (1 Car, 2 Cars and Group Operation) When a car does not receive any registered calls within a preset time, this service function moves the car to a predetermined floor and waits in standby mode for a call registration. TM SAFETY FUNCTIONS TM IONFUL: Plasmacluster Ion Generating System Plasmacluster Ion Generating System, which is built-in to a car's ventilation unit, creates clean air for passenger comfort by eliminating germs, odors, bacteria, and allergens inside the car. Anti-Nuisance Function All car calls will be automatically canceled when an extraordinary number of car calls are registered within a very short time and/or when more than 4 calls are registered but the in-car load is below 100kg. Independent Operation A car designated for exclusive-use will operate independently. When turned on, the designated car shall respond to car calls only. Reverse-Direction Car-Call Cancellation When a passenger tries to register a car call that is behind the current traveling direction, the system will regard it as a nuisance call and ignore it in order to maintain elevator service efficiently. Attendant Operation Mistaken Car-Call Cancellation In the case of a mistaken car call registration, 2 consecutive pushes on the registered button within 0.3 to 1.0 second will cancel the call registration. Rescue Operation to the Nearest Floor a) The car responds to both car and landing calls. b) When the car is stopped,pressing the "up or down" button on the car console will select the travel direction and continuously pressing the same button will close the car door. In case a car prematurely stops between floors, a safety circuit will check and determine the situation, then automatically and slowly move the car to the nearest available floor. Auto Adjustment of Open-Door Duration Door Opening Failure Rescue Operation In case of a door opening failure after arriving at the destination floor, the car will move to the next available floor and automatically open the door. a) Based on registered car and landing calls, the system automatically adjusts the duration (dwell time) for which a car stays and keeps its doors open at every floor. b) In accordance with other factors after the doors open (multi-beam sensor, door open button usage), the system automatically adjusts the duration for which a car stays and keeps its doors open at every floor . Auto-Separation after Elevator Failure (2 Cars) In case a car is operating abnormally, the elevator group control system will separate the affected car from group control and operate the remaining car normally. Automatic Fan and Light Control In case a car doesn' t receive any registered calls for a preset time, its ventilation fan and lights will automatically turn off, so as to reduce energy usage. Open Door Warning In case the passenger(s) try to forcibly open the car doors during operation or when stopped in an un-leveling zone, a warning device will sound an alarm. If the passenger(s) still continue to force the doors open, the car will protectively stop or remain stopped and only restart after confirming the doors are closed. In the event a car is overloaded, the car doors will not close and an audible alarm will sound and the car console will display "OVERLOAD". Visual Display on COB (Car Operating Board) A visual display on the COB will provide passengers with timely text messages reflecting current conditions such as "OVERLOAD", "EMER. OPERATION" (Optional Function). The message can be synchronized with VONIC to provide visual and audio information. Return Signal Output from Evacuation Floor In the event of a fire, the elevator will send a feedback signal to the building system after returning to the designated evacuation floor. Overload Warning Auto Re-Leveling In case a car does not stop flush with a landing, the device will re-level the car by creeping it up or down. Door Nudging Multi-Beam Door Sensor In the event that car doors remain open past a preset time, the device will initiate a slow-door-closing operation while sounding an audible alarm (The multi-beam door sensor is ignored but the mechanical safety edge system is still active when the door is forcibly closed.). In case a car is unable to complete door-opening operation at a destination floor within a preset time, the device will move the car to another destination floor registered by the car or a landing call. In the case of something obstructing door-closing operation past a preset time, a respective door-closing operation will start to clear the doorway obstruction. The sensor emits multiple infrared beams, creating an invisible curtain covering the entire doorway, even if only a single beam is interrupted, the sensor will stop the closing doors and reopen them. Five-Way Interphone System An interphone system for 5-way communication is installed in the car console. It allows 4 remote interphones to communicate with the car top, pit, machine room and building security room. Alarm Buzzer (On Car Top) When the emergency button on the car console is pressed, the interphones in the elevator machine room and the building security room will sound a warning alarm, and in addition a buzzer mounted on the car top will sound an alarm. Emergency Car Lighting SAFETY FUNCTIONS Firefighter's Operation This operation will allow firefighters use of a car for rapid building access. For emergencies, the car will only respond to car calls registered by firefighters. LANDIC: Battery Powered Automatic Landing Operation In case a power failure causes passengers to become trapped in a car, a compact battery power source will move the car to the nearest available floor, and open the doors to enable passengers to exit safely. Multi-Beam Door Sensor with Mechanical Safety Edge A mechanical safety edge device can be incorporated with the multi-beam system for car doors. Standby Power Operation If a power failure occurs, the car will return to a predetermined evacuation floor or the nearest floor using standby power and will be stopped there on standby. Provisions for standby power supply shall be supplied by others. In case there is no interior car lighting, a self-charging battery power source will immediately light up the emergency car lights for passenger safety and relief. Auto-Separation after Elevator Failure (Group Control) In the event that a car is operating abnormally under group control, the car will automatically be separated from the group so as to ensure efficient group control operation of the remaining elevators. Night-Time SelfDiagnostic Operation The elevator automatically checks operation conditions and brake system during the night-time and when not receiving any registered calls. This operation increases passenger safety and maintains high after-sales product quality. SERVICE FUNCTIONS Power Phase Error Monitoring Start/ run prevention during phase loss or power supply disruption. Load By-Pass If a traveling car is loaded up to its rated load capacity, it will bypass floors where landing calls have been registered. Those registered landing calls will be assigned to the next available car. Operation Time Monitoring The total operation time of the elevator is recorded in the controller. Visual Display at the Landing The landing indicator will display messages corresponding to special conditions; for example, in the "Load By-Pass" condition, the displays at all floors, with the exception of the terminal floors, will display "FULL". Emergency-Stop Switches Emergency stop switches are installed on the car top and in the pit. Parking Operation When elevator operation is shifted to Parking Operation, the designated car(s) will move to and stop at a pre-assigned floor with doors closed and car lights and fan turned off. Starting Time Counter The starting times of the elevator is recorded in the controller. Overspeed Protection (Electrical) When the car overspeeds, the electrical protection device detects and stops the car in time. Arrival Chime (Inside the Car) An arrival chime inside the car will sound softly when a car has arrived at a destination floor. Overspeed Protection (Mechanical) When the car overspeeds, the mechanical protection device detects and stops the car in time. VONIC: Automatic Voice Announcement System (English) A computerized voice provides passengers with timely information about car directions, car arrivals, door opening and closing, emergencies, etc. Standard language is English. For other languages, please consult Fujitec representative. Motor Idle Protection When the steel wire rope slides, the elevator is capable of inspecting and stopping the operation. When the position of the stopped car and the displayed floor do not match, the elevator will automatically correct the deviation by reaching the terminal floor at once. Automatic Run / Stop Operation (By Timer) Elevators can automatically be put temporarily out of service via a preset time schedule. Auto Adjustment of Car Position Error Auto Detection and Error Recording The elevator will automatically detect and record the errors and irregularities through the control system to prevent the expected trouble and swift trouble shooting. Power Receptacle in a Car A power receptacle can be installed in the car. (Maximum Wattage : 1KW). Electromagnetic Interference Filter This device will reduce interference with peripheral equipment by the elevator and improve the elevator's antiinterference stability. BMS(Building Management System) Interface Through a purpose-built interface, a building management system can receive up-to-date elevator operation data. Fire Operation In the event of a fire, the device will automatically clear all registered calls and move the car directly to a predetermined evacuation floor and immobilize it there (please consult with Fujitec representative in case there are more than two evacuation floors to be assigned.). CCTV Cable For a CCTV camera, video-signal cables suitable for the hoistway traveling cable and machine room are provided. Group Supervisory Control (GSO) The new FLEX-NX system utilizes optimal group supervisory control functions which enhances transport efficiency. Door Operation Inspection Device Car Door Opening Protection Device This device prevents the car door from opening in a non-locking area and protects passengers from falling into the hoistway. Impact Resistant Landing Door System This system further strengthens the impact resistance of the landing door, effectively protecting passengers from falling into the hoistway. Unintended Car Movement Protection (UCMP) The UCMP system will immobilize the car if the car and landing doors are opened but are not aligned correctly, so as to protect against personal injury and equipment damage. 21 Standard Functions Optional Functions Human Friendly Functions No further notice is provided if there is any change for specification, please understand. 22 Planning Specification 450Kg / 2 Panels - Right Side Opening (2SR) (opposite application for 2SL) Main Specifications Capacity Speed Number of Stops 450kg、630kg、800kg、1050kg、 1200kg、1350kg 1.0mps、1.5mps、1.75mps、 2.0mps、2.5mps Up to 40 Stops/ Floors 630Kg~1350Kg (2 Panels - Center Opening) Remarks: 2.5mps speed is not be applicable for 450kg and 630kg capacity cars. Control System Driving System Up to 110m (up to 1.75mps), 130m (2.0mps and 2.5mps) VVVF and 32-bit Computer Distributed Control System Permanent Magnet Synchronous Gearless System Operation Mode Door Operation System Door Opening Single Car, 2 Cars, Group Control System (3 - 8 Cars) VVVF Control and Permanent Magnet Gearless Door Operator 2 Panels - Center Opening Travel Height Remark:2 Panels - Side Opening for 450kg Capacity No further notice will be provided if there are specification changes. 23 The above dimensions are for reference only, the actual engineering design data will be used. 24 Planning Standard Specification (Wall Mounted Type) Planning Machine Room and Hoistway Plan (Wide Car) Optional Specification (Box Type) Optional Specification (Box Type) *1. For 450kg, 630kg, 800kg and 1,350kg capacity cars, the single wrap machine is applied. For 1050kg and 1200kg capacity cars, the full wrap machine is applied. *2.The shown arrangement of the machine room door is only an example. Please consult us for actual arrangement. *3.The shown arrangement of the control panel is only an example. Please consult us for actual arrangement. *4. Dimension tolerance of hoistway shall be +25mm/-0mm. *5. The didmension shall be based on the hoistway with RC-structure. *6. The hoistway's internal dimension shall be calculated after the pit waterproof finish. *7. If the hoistway's internal dimension is too large, it will be necessary to provide intermediate beams. *8. The hoistway's structural wall thickness shall be 150mm or more (not including the finish). *9. The above dimensions are for reference only, the actual engineering design data will be used. The above dimensions are for reference only, the actual engineering design data will supersede. 25 26 Planning Relevant Dimensions Machine Room and Hoistway Plan (Deep Car) Rear Counter-Weight Load- Bearing of Hanging Hook - 3,000kg COB Over Head Height (OH) 2100 (H) Max.7000mm - Separation Distance 1 Depth (Y) Depth (B) 500 Effective Height of the Machine Room (MH) (Work by Others) Width (W) Width (A) Width (X) Hoistway Plan Total Height Traveling Height Top Floor Side Counter-Weight Width (MX) Hoistway Lighting Ventilation Window (Work by Others) (Work by Others) Temperature Sensor (Work by Others) Ventilation Window (Work by Others) R2 Bottom Floor Hoistway Lighting Switch Installation (Work by Others) Pit Depth (P) Receptacle (Work by Others) 500 Pit Inspection Receptacle Depth (MY) R1 2100 (H) Max.7000mm - Separation Distance Governor Receiving Box (Work by Others) COP Machine Room Door W950xH1900 Hatch Side In case the capacity is 450kg, the size of the standard machine room is increased by 100mm in the left and right width than the size of the hoistway. R3 R4 Hoistway Section (Work by Others) *1. In case the capacity is 800kg, the single wrap machine is applied. In case the capacity is 1050kg, 1200kg and 1350kg, the full wrap machine is applied. *2.The arrangement of the machine room door is only an example. Please inquire us for the actual arrangement. *3.The arrangement of the control panel is only an example. Please inquire us for the actual arrangement. *4. Dimension tolerance of hoistway shall be +25mm/-0mm. *5. The didmension shall be based on the hoistway with RC-structure. *6. The hoistway's internal dimension shall be calculated after the pit waterproof finish. *7. If the hoistway's internal dimension is too large, it will be necessary to provide intermediate beams. *8. The hoistway's structural wall thickness shall be 150mm or more (not including the finish). *9. The above dimensions are for reference only, the actual engineering design data will be used. 27 The car internal heights and top heights vary by the ceiling type. For details, please contact our sales persons. Water Proofing Machine Room Plan The above dimensions are for reference only, the actual engineering design data will supersede. 28 Other Works Power Supply Data Ambient Requirements Hoistway Internal Temperature Within 5℃~ 40℃ Relative Humidity The relative humidity of the air shall not exceed 50% if the highest temperature of 40℃ is reached. Comparatively, if the temperature is lower, the relative humidity can be higher. If the monthly average low temperature during the most humid month is no more than 25℃, then the highest relative humidity of that month shall not exceed 90%. If condensation occurs on electrical equipment, relevant counter-measures must be taken. Power Supply Three-Phase Voltage Fluctuation Range ± 7% Work by Others Hoistway The structure of the elevator hoistway shall be solid, subjected to fire-proofing treatment and provided with required holes for relevant equipment. The plane dimension of the hoistway is the minimum size determined with plumbing. The vertical allowable deviation of the hoistway is as follows: Hoistway height is less than 30m: 0~+25mm Hoistway height is more than 30m and less than 60m: 0~+35mm Hoistway height is more than 60m: 0~+50mm Cement filling around the entrance jambs. Cement filling surrounding the wall after relevant elevator fixtures are installed. Waterproofing work (including pumping equipment and waterproof treatment after the elevator equipment is installed as required) in the pit. Divider screens and intermediate support beams when the hoistway is shared (the height of the divider screen will extend to 2.5m above the pit level from the lowest point of the car or counter-weight stroke. The intermediate support beams can be I-beams, and the position of the beams shall be shown in the position of the rail bracket in the hoistway drawings, but shall not interfere with the reserved hole of the landing buttons.) In case the hoistway is in a brick structure, a ring beam is required, of which the height is not less than 300mm, to be placed, so as to install the rail bracket. (The position of the ring beam shall be shown in the position of the rail bracket in the hoistway drawing.) Installation of emergency exit doors when the distance between the sills of two adjacent landing doors is more than 11m. (1) Actual values may differ from the above according to the specifications. (2) The rated short circuit breaking capacity is 7.5KA. (3) When power capacity is selected, the voltage drop at full load and acceleration current should be fluctuated. (4) Please prepare grounding wire specifications according to relevant local codes. It would be better not to arrange the space that the people can enter below the pit. Machine Room The structure of the machine room and fire-proofing work, and the installation of the entrance (Includes noise reduction work and provisions for smoke detector(s) as required). In the machine room, each elevator shall be separately equipped with a master switch capable of cutting off all power supply circuits; and this switch shall be capable of cutting off the maximum current when the elevator is in normal use, and have the stable off position and on position, so as to be locked with a padlock or other equivalent locking device in the off position. Providing holes in the machine room (the floor must be able to bear 700kg/ m2) Providing holes for machine support beams in the machine room and filling work after installation. Lightweight concrete and dustproof finish after the piping work on the machine room floor. Provisions for the entrance of the traction machine and other machineries and its restoration. Provisions for a lifting beam or hook for the machine in the machine room (Note the capacity of the beam/ hook.). Installation of a window and louver for sun light. Installation of stairs to access the machine room. Installation of a ladder and guardrail is required if the floor difference in the machine room is more than 500mm. Relevant Elevator Equipment Installation of the switchboard for power in the machine room and the lead and wiring of power supply and lighting to the control panel of the elevator. (The supply voltage fluctuation shall be within ±7%) Piping and wiring for interphones and emergency alarm outside the hoistway and machine room. Provisions for lighting equipment in the machine room. (The brightness of the floor in the machine room shall not be less than 200lx) Provisions for exhaust fan(s) or air conditioning equipment in the machine room. (The air temperature in the machine room shall be kept within 5℃~ 40℃.) Provisions for a power socket for machine room and pit inspections. Hoistway Lighting. Install low-voltage (30W) lamps 0.5 meters from the highest and lowest points in the hoistway respectively and at every 7m (maximum) in the middle of the hoistway. The illuminance above the car roof and at 1m above the ground of the pit shall be 50lx at least. A switch for the hoistway lighting will be installed in the machine room and pit respectively. Other Notes Please use a high-order harmonic prevention product if the electric leakage breaker or electric leakage alarm is installed. arranged. In the building, a 500mm clearance distance must be maintained when installing the telecommunication cable and power line of the elevator. The corroding metal, damaged and insulated gas and conductive dust shall not be provided in the machine room and the hoistway. Storage for elevator parts and installation materials shall be provided. The above dimensions are for reference only, the actual engineering design data will supersede. 29 No further notice will be provided if there is any future specification changes. 30 Fujitec Global Operations Langfang Plant (China) Shanghai Fujitec City (China) Ohio Plant (United States) Korea Plant India Plant Singapore Plant North & South America Japan East Asia FUJITEC AMERICA, INC. FUJITEC CANADA, INC. FUJITEC VENEZUELA C.A. FUJITEC ARGENTINA S.A. FUJITEC URUGUAY S.A. FUJITEC CO., LTD. FUJITEC (HK) CO., LTD. Europe & Middle East Big Wing (Group Headquarters in Japan, Elevator Plant) FUJITEC UK LTD. FUJITEC DEUTSCHLAND GmbH FUJITEC SAUDI ARABIA CO., LTD. FUJITEC EGYPT CO., LTD. FUJITEC UAE (DUBAI) OFFICE FUJITEC TAIWAN CO., LTD. South Asia FUJITEC SINGAPORE CORPN. LTD. FUJITEC INC. (PHILIPPINES) FUJITEC (MALAYSIA) SDN. BHD. P.T. FUJITEC INDONESIA FUJITEC KOREA CO., LTD. HUASHENG FUJITEC ELEVATOR CO., LTD. SHANGHAI HUASHENG FUJITEC ESCALATOR CO., LTD. FUJITEC SHANGHAI TECHNOLOGIES CO., LTD. FUJITEC SHANGHAI SOURCING CENTER CO., LTD. FUJITEC VIETNAM CO., LTD. FUJITEC INDIA PRIVATE LTD. FUJITEC (THAILAND) CO., LTD. FUJITEC LANKA(PRIVATE) LTD. FUJITEC PACIFIC, INC. (GUAM) 31 32