Submittal Package for DuPont™ Tyvek® CommercialWrap® and
Transcription
Submittal Package for DuPont™ Tyvek® CommercialWrap® and
Submittal Package for DuPont ™ Tyvek ® CommercialWrap® and CommercialWrap® D Related Links: DuPont™ Tyvek® CommercialWrap® Substitution Request Form DuPont™ Tyvek® CommercialWrap® D Substitution Request Form Commercial Weather Barrier Installation Guidelines Distributed by Commercial Flashing Installation Guidelines DuPont™ Tyvek® ESR Code Report For support: weatherizationpartners.com TECHNICAL DATA SHEET DUPONT™ TYVEK® COMMERCIALWRAP® A DURABLE, HIGH PERFORMANCE WEATHER BARRIER ENGINEERED SPECIFICALLY FOR COMMERCIAL CONSTRUCTION DESCRIPTION Engineered to provide excellent performance as an air and water barrier, Tyvek® CommercialWrap® delivers the added strength and durability needed in commercial construction. As a part of DuPont™ Tyvek® Commercial Air and Water Barrier Systems, Tyvek® CommercialWrap® can easily be integrated with other system components to provide superior air and water hold-out with high tear-resistance, high wind-load resistance and 9-month UV resistance. It provides the best balance of air and moisture management resulting in more durable and energy efficient structures. Tyvek® CommercialWrap® is backed by a 10-year limited warranty and industryleading technical support. TYPICAL PROPERTIES (JULY, 2014) Please contact your local DuPont™ Tyvek® Specialist before writing specifications around this product. Product properties are as follows. Test Method PRODUCT INFORMATION–FEATURES/BENEFITS Air and Water Barrier Performance • Offers the ideal combination of air and water holdout plus vapor permeability. • Air Barrier Association of America evaluated to exceed ABAA, ASHRAE 90.1 and IECC air leakage requirements when tested in accordance with ASTM E2357. Ease of Installation • Easily installed, prior to the building’s exterior facade, to help protect against air and water infiltration. High Performance Durability • Offers high tear-resistance and high wind-load-resistance to help stand up to commercial construction site conditions. • Withstands up to nine months of UV exposure. Sustainable Solutions •DuPont Tyvek CommercialWrap may contribute toward LEED points in the areas of Energy and Atmosphere (EA): Optimizing the Building Envelope and Indoor Environmental Air Quality (EQ): Construction IAQ Management Plan and Low Emitting Materials. In addition, the use of a continuous air barrier is a prerequisite for LEED® applications requiring compliance with ASHRAE 90.1-2010. ™ ® ® ® Property Unit Value ASTM E2357 Air Penetration Resistance cfm/ft @ 1.57 psf <0.01 Gurley Hill (TAPPI T-460) Air Penetration Resistance sec/100cc >1500 ASTM E1677 Air Penetration Resistance cfm/ft2 @ 1.57 psf Type 1 ASTM E2178 Air Penetration Resistance cfm/ft2 @ 1.57 psf .001 ASTM E283 Wall Assembly Air Penetration Resistance ASTM E96-00 Water Vapor Transmission Method A g/m2-24 hrs 163 ASTM E96-00 Water Vapor Transmission Method A (perms) 23 ASTM E96-00 Water Vapor Transmission Method B g/m2-24 hrs 200 ASTM E96-00 Water Vapor Transmission Method B (perms) 28 cm 280 2.7 2 AATCC 127 Water Penetration Resistance ASTM E331 Wall Assembly Water Penetration Resistance TAPPI T-410 Basis Weight oz/yd2 lbs/in 38/35 lbs 12/10 ASTM D882 Breaking Strength ASTM D1117 Tear Resistance • By helping to effectively seal the building envelope, Tyvek® CommercialWrap® helps to reduce the amount of energy required for heating and cooling ASTM E84 Surface Burning Characteristics Flame Spread Index Class 10 Class A Complete System ASTM E84 Surface Burning Characteristics Smoke Developed Index Class 10 Class A NFPA 285 Flame Propagation/Multiple Assemblies – Pass Days Months 270 9 Tyvek® CommercialWrap® can be integrated with DuPont self-adhered flashing products and Tyvek® Fluid Applied products to offer seamless protection for wall systems that require mechanically fastened and fluid applied air and water barriers. Ultra Violet Light Exposure (UV) Test results shown represent roll averages. Individual results may vary either above or below averages due to normal manufacturing variations, while continuing to meet product specifications TECHNICAL DATA SHEET DUPONT™ TYVEK® COMMERCIALWRAP® A DURABLE, HIGH PERFORMANCE WEATHER BARRIER ENGINEERED SPECIFICALLY FOR COMMERCIAL CONSTRUCTION PRODUCT DESCRIPTION Tyvek® CommercialWrap® is made from 100% flash spunbonded high density polyethylene fibers which have been bonded together by heat and pressure, without binders or fillers, into a tough durable sheet structure. Additives have been incorporated into the polyethylene to provide ultraviolet light resistance. INSTALLATION/USE INSTRUCTIONS Please refer to DuPont Installation Guidelines for complete instructions. Safety Precautions for Use Tyvek® CommercialWrap® is slippery and should not be used in any application where it will be walked on. In addition, DuPont recommends using kick jacks, scaffolding, or lifts for exterior work above the first floor. If ladders must be used, extra caution must be taken to use them safely by following the requirements set forth in ANSI Standards 14.1, 14.2, and 14.5 for ladders made of wood, aluminum, and fiberglass, respectively. Tyvek® CommercialWrap® is combustible and should be protected from flames and other high heat sources. Tyvek® CommercialWrap® will melt at 275°F (135°C) and if the temperature of the product reaches 750°F (400°C), it will burn and the fire may spread and fall away from the point of ignition. For more information, call 1-800-44-Tyvek. Preparation No surface preparation is needed for the installation of Tyvek® CommercialWrap®. TESTING/CODE COMPLIANCE Moisture Protection – Weather-Resistant Barriers Other The 2012 International Building Code (IBC, Section 1403.2 Weather Protection) requires that exterior walls shall provide the building with a weather-resistant exterior wall envelope. This shall include flashing, as described in Section 1405.4. Tyvek® CommercialWrap® and where applicable, DuPont self-adhered flashing and accessory products, have been tested and meet weather-resistant barrier codes and standards requirements. The following test methodologies were used: • NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components • ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform StaticPressure • ASTM E2556 Standard Specification for Vapor Permeable Flexible Sheet Water-resistive Barriers intended for mechanical attachment • ASTM E96-00 Standard Test Methods for Water Vapor Transmission of Materials; Water resistive barriers are typically vapor permeable, which is generally desirable because it allows for drying of incidental moisture intrusion into the wall assembly • ASTM E 84 Standard Test Method for Surface Burning Characteristics of Building Materials Tyvek® CommercialWrap®, in conjunction with DuPont self-adhered flashing and accessory products, have been evaluated according to Air Barrier Association of America (ABAA) protocol and are listed at the ABAA website under “ABAA evaluated Air Barrier Assemblies”, www.airbarrier.org NOTICE Tyvek® CommercialWrap® should be covered with the facade within nine months to limit UV exposure. Follow facade manufacturer’s installation and maintenance requirements in order to maintain water holdout. MATERIAL STORAGE/DISPOSAL Tyvek® CommercialWrap® should be stored in a clean, dry environment. • AATCC 127 Hydrostatic Head Test for water-resistant barrier materials, measuring pressure to failure or time of failure at a given pressure Tyvek® CommercialWrap® is available the following roll sizes: Air Leakage Control — Air Barriers • 5’ x 200’ (1.5 x 61m) ASHRAE 90.1 2010 (American Society of Heating, Refrigerating and Air-Conditioning Engineers) requires that the entire building envelope shall be designed and constructed with a continuous air barrier. This is a mandatory provision for the building envelope. IECC 2012 (International Energy Conservation Code) for commercial buildings also requires a continuous air barrier. These codes are being adopted in many states across the United States. Tyvek® CommercialWrap and where applicable, DuPont self-adhered flashing and accessory products have been tested and meet air barrier codes and standards requirements. The following test methodologies were used: • 10’ x 125’ (3.1 x 38.1 m) PACKAGING WARRANTY Backed by a limited product warranty, see www.weatherization.tyvek.com. • ASTM E2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies • ASTM E1677 Standard Specification for an Air Retarder (AR) Material or System for Low-Rise Framed Building Walls • ASTM E2178 Standard Test Method for Air Permeance of Building Materials • ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen Copyright © 2014 E. I. du Pont de Nemours and Company. All Rights Reserved. The DuPont Oval Logo, DuPont™, The miracles of science™, CommercialWrap® and Tyvek®, are registered trademarks or trademarks of E.I. du Pont de Nemours and Company or its affiliates. K-27289 (7/14) TECHNICAL DATA SHEET DUPONT™ TYVEK® COMMERCIALWRAP® D A DURABLE, HIGH PERFORMANCE, MECHANICALLY FASTENED AIR AND WATER BARRIER ENGINEERED TO IMPROVE DRAINAGE AND TO STAND UP TO THE COMMERCIAL JOB SITE DESCRIPTION Tyvek® CommercialWrap® D offers superior drainage and durability for commercial buildings. It features a specially engineered surface texture that provides enhanced water drainage under a wide variety of facades in climates that may require additional drainage. As a part of DuPont™ Tyvek® Commercial Air and Water Barrier Systems, Tyvek® CommercialWrap® D can easily be integrated with other system components to provide superior air and water hold-out with high tear-resistance, high wind-loadresistance and 9-month UV resistance. Tyvek® CommercialWrap® D is backed by a 10-year limited warranty and industry-leading technical support. TYPICAL PROPERTIES (JULY, 2014) Please contact your local DuPont™ Tyvek® Specialist before writing specifications around this product. Product properties are as follows: Test Method Property Unit Value ASTM E2357 Air Penetration Resistance cfm/ft @ 1.57 psf <0.04 Gurley Hill (TAPPI T-460) Air Penetration Resistance sec/100cc >750 ASTM E1677 Air Penetration Resistance cfm/ft2 @ 1.57 psf Type 1 ASTM E2178 Air Penetration Resistance cfm/ft2 @ 1.57 psf .001 • Easily installed, prior to the building’s exterior facade, to help protect against air and water infiltration. ASTM E283 Wall Assembly Air Penetration Resistance High Performance Durability ASTM E96-05 Water Vapor Transmission 212 • Offers high tear-resistance and high wind-load-resistance to help stand up to commercial construction site conditions. Method B g/m2-24 hrs ASTM E96-05 Water Vapor Transmission Method B (perms) 30 cm 235 PRODUCT INFORMATION–FEATURES/BENEFITS Air and Water Barrier Performance • Offers the ideal combination of enhanced drainage, air and water holdout plus vapor permeability. • Air Barrier Association of America evaluated to exceed ABAA, ASHRAE 90.1 and IECC air leakage requirements when tested in accordance with ASTM E2357 Ease of Installation • Withstands up to nine months of UV exposure. 2 AATCC 127 Water Penetration Resistance •DuPont™ Tyvek® CommercialWrap® D may contribute toward LEED® points in the areas of Energy and Atmosphere (EA): Optimizing the Building Envelope and Indoor Environmental Air Quality (EQ): Construction IAQ Management Plan and Low Emitting Materials. In addition, the use of a continuous air barrier is a prerequisite for LEED® applications requiring compliance with ASHRAE 90.1-2010. ASTM E331 Wall Assembly Water Penetration Resistance TAPPI T-410 Basis Weight oz/yd2 2.4 ASTM D882 Breaking Strength lbs/in 33/41 • By helping to effectively seal the building envelope, Tyvek® CommercialWrap® D helps to reduce the amount of energy required for heating and cooling ASTM D1117 Tear Resistance lbs 6/9 ASTM E84 Surface Burning Characteristics Flame Spread Index Class 15 Class A ASTM E84 Surface Burning Characteristics Smoke Developed Index Class 25 Class A NFPA 285 Flame Propagation/Multiple Assemblies – Pass Days Months 270 9 Sustainable Solutions Complete System Tyvek® CommercialWrap® D can be integrated with DuPont self-adhered flashing products and Tyvek® Fluid Applied products to offer seamless protection for wall systems that require mechanically fastened and fluid applied air and water barriers. Ultra Violet Light Exposure (UV) Test results shown represent roll averages. Individual results may vary either above or below averages due to normal manufacturing variations, while continuing to meet product specifications. TECHNICAL DATA SHEET DUPONT™ TYVEK® COMMERCIALWRAP® D A DURABLE WEATHER BARRIER ENGINEERED FOR ENHANCED DRAINAGE PRODUCT DESCRIPTION Tyvek® CommercialWrap® D is made from 100% flash spunbonded high density polyethylene fibers which have been bonded together by heat and pressure, without binders or fillers, into a tough durable sheet structure. Additives have been incorporated into the polyethylene to provide ultraviolet light resistance. INSTALLATION/USE INSTRUCTIONS Please refer to DuPont Installation Guidelines for complete instructions. Safety Precautions for Use Tyvek® CommercialWrap® D is slippery and should not be used in any application where it will be walked on. In addition, DuPont recommends using kick jacks, scaffolding, or lifts for exterior work above the first floor. If ladders must be used, extra caution must be taken to use them safely by following the requirements set forth in ANSI Standards 14.1, 14.2, and 14.5 for ladders made of wood, aluminum, and fiberglass, respectively. Tyvek® CommercialWrap® D is combustible and should be protected from flames and other high heat sources. Tyvek® CommercialWrap® D will melt at 275°F (135°C) and if the temperature of the product reaches 750°F (400°C), it will burn and the fire may spread and fall away from the point of ignition. For more information, call 1-800-44-Tyvek. Preparation No surface preparation is needed for the installation of Tyvek® CommercialWrap® D. TESTING/CODE COMPLIANCE Moisture Protection – Weather-Resistant Barriers Other The 2012 International Building Code (IBC, Section 1403.2 Weather Protection) requires that exterior walls shall provide the building with a weather-resistant exterior wall envelope. This shall include flashing, as described in Section 1405.4. Tyvek® CommercialWrap® D and where applicable, DuPont self-adhered flashing and accessory products, have been tested and meet weather-resistant barrier codes and standards requirements. The following test methodologies were used: • NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components • ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform StaticPressure • ASTM E2556 Standard Specification for Vapor Permeable Flexible Sheet Water-resistive Barriers intended for mechanical attachment • ASTM E96-00 Standard Test Methods for Water Vapor Transmission of Materials; Water resistive barriers are typically vapor permeable, which is generally desirable because it allows for drying of incidental moisture intrusion into the wall assembly • ASTM E 84 Standard Test Method for Surface Burning Characteristics of Building Materials Tyvek® CommercialWrap® D, in conjunction with DuPont self-adhered flashing and accessory products, have been evaluated according to Air Barrier Association of America (ABAA) protocol and are listed at the ABAA website under “ABAA evaluated Air Barrier Assemblies”, www.airbarrier.org NOTICE Tyvek® CommercialWrap® D should be covered with the facade within nine months to limit UV exposure. Follow facade manufacturer’s installation and maintenance requirements in order to maintain water holdout. MATERIAL STORAGE/DISPOSAL Tyvek® CommercialWrap® D should be stored in a clean, dry environment. • AATCC 127 Hydrostatic Head Test for water-resistant barrier materials, measuring pressure to failure or time of failure at a given pressure Tyvek® CommercialWrap® D is available the following roll sizes: Air Leakage Control — Air Barriers • 5’ x 200’ (1.5 x 61m) ASHRAE 90.1 2010 (American Society of Heating, Refrigerating and Air-Conditioning Engineers) requires that the entire building envelope shall be designed and constructed with a continuous air barrier. This is a mandatory provision for the building envelope. IECC 2012 (International Energy Conservation Code) for commercial buildings also requires a continuous air barrier. These codes are being adopted in many states across the United States. Tyvek® CommercialWrap D and where applicable, DuPont self-adhered flashing and accessory products have been tested and meet air barrier codes and standards requirements. The following test methodologies were used: • 10’ x 125’ (3.1 x 38.1 m) PACKAGING WARRANTY Backed by a limited product warranty, see www.weatherization.tyvek.com. • ASTM E2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies • ASTM E1677 Standard Specification for an Air Retarder (AR) Material or System for Low-Rise Framed Building Walls • ASTM E2178 Standard Test Method for Air Permeance of Building Materials • ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen Copyright © 2014 E. I. du Pont de Nemours and Company. All Rights Reserved. The DuPont Oval Logo, DuPont™, The miracles of science™, CommercialWrap® and Tyvek®, are registered trademarks or trademarks of E.I. du Pont de Nemours and Company or its affiliates. K-27288 (7/14) DuPont Flashing Systems physical properties data sheet Product Data Properties DuPont™ FlexWrap™ NF DuPont™ FlexWrap™ RW DuPont™ FlASHING TAPE Face Sheet Micro-creped, polyethylene laminate (white) Elasticized polyethylene laminate (white) Polypropylene film Adhesive* Butyl Rubber (black) Butyl Rubber (black) Butyl Rubber (black) Thickness 64 mil (1,620 microns) 70 mil (1,775 microns) 20 mil (507 microns) Release Liner 1-piece, heavy-duty siliconized paper for 6-inch width product; 2-piece, heavy-duty siliconized paper for 9-inch width product Custom-designed, multi-piece, heavy-duty siliconized paper 1-piece heavy-duty siliconized paper Dimensions 6- or 9-inch width x 75 feet length 9-inch width x 6-inch length custom folded pieces 4, 6, or 9-inch width x 100 feet Applications Round top or custom shaped windows, 3-D sill protection, wall interruptions: i.e. dryer vents, hose bibs. Suitable for use on substrates where fasteners cannot be applied. Corner pieces for sill and head of recessed windows. Available in single-stud or double-stud versions. Jambs and heads of rectangular windows and doors. Properties DuPont™ StraightFlash™ DuPont™ StraightFlash™ VF Face Sheet Spunbonded polyethylene laminate (white) Spunbonded polyethylene laminate (white) Adhesive* Butyl rubber (black) Transposed dual sided adhesive for continuous integration; Butyl rubber (black) Thickness 30 mil (760 microns) 30 mil (760 microns) Release Liner 2-piece, heavy-duty siliconized, scored release paper 2-piece, heavy-duty siliconized, scored release paper Dimensions 4-inch width x 150 feet length 9-inch width x 125 feet length 6-inch width x 125 feet length Applications Jambs and heads of rectangular windows. Brick mold, non-integral flanged and non-flanged rectangular windows and doors. * Adhesive system is based on 100% butyl elastomer with no asphalt/modified bitumen components. Performance Testing Installed System Water Intrusion Testing (Tested with no exterior cladding) ASTM E-331NO leakage at 300 Pa ASTM E-331 after thermal aging (0-160°F)NO leakage at 300 Pa WATER VAPOR PERMEABILITY (ASTM E-96) < 1 perm (< 60 ng/Pa.sec.m2) APPLICATION TEMPERATURE Best when installed above 25°F (consult DuPont for primer recommendations) UV RESISTANCE Cover within 120 days DuPont Flashing Systems products meet the AAMA 711-07 material standard at the highest classification levels: For more information about DuPont Flashing Systems, please visit us at www.Construction.Tyvek.com or call 1-800-44-Tyvek Class A (no primer) Level 3 Thermal Exposure (80°C/176°F for 7 days) WARNING: DuPont Flashing Systems products and their release paper are slippery and should not be walked on. Remove release paper from work area immediately. DuPont Flashing Systems products are combustible and should be protected from flame and other high heat sources. If the temperature of DuPont Flashing Systems products reach 700°F (307°C) they will burn and the fire may spread and fall away from the point of ignition. Copyright © 2011 E.I. du Pont de Nemours and Company. All rights reserved. The DuPont Oval Logo, DuPont™, The miracles of science™, FlexWrap™, and StraightFlash™ are registered trademarks or trademarks of E.I. du Pont de Nemours and Company or its affiliates. K-25126 07/11 DuPont Tyvek Tape ™ ® Building science bulletin Specify DuPont Tyvek Tape in commercial building applications to finish the job right. ™ ® In commercial construction, DuPont Tyvek Tape is the crucial final step for maximum reduction of air and water infiltration through the building envelope. ™ ® Using a quality weather barrier on a commercial building is as important as installing it properly. Taping the seams after wrapping, in addition to taping any tears or holes, is the best practice for maximum reduction of air and water intrusion into the building envelope. DuPont Tyvek Tape features a specially engineered adhesive to create the best adhesion to DuPont Tyvek Weather Barrier Systems in any climate. DuPont Tyvek Tape works when other tapes won’t, sealing seams for a continuous protective barrier against air and water infiltration. ™ ® ™ DuPont Tyvek Tape is specially engineered to provide the best adhesion to DuPont Tyvek . ™ ® ™ ® ® ™ Not all tapes are created equal. Desired qualities of a sheathing tape Strength High tack Temperature resistant UV resistant Pliability Ease of use Taping the seams after wrapping is the best practice for completely sealing the building envelope. Permanent acrylic adhesive Meets Canadian Construction Material Center's Standard 7281 for sheathing DuPont Tyvek Tape Duct tape • • • • • • • • • ™ ® • • • Blue outdoor masking tape Carton sealing tape • • • • • • • ® Technical data Complete system of products • Tape materials – UV resistant, biaxially-oriented polypropylene film coated with a specially formulated permanent acrylic adhesive. • Roll Length – 50 m (54.68 yds) • Tensile strength – 27 lbs/in. • Elongation – 125% • Meets Canadian Construction Material Center’s Standard 7281 for sheathing tape. For optimal protection on all your building projects, use DuPont Tyvek Tape with DuPont Tyvek Weather Barrier Systems including DuPont Tyvek CommercialWrap , DuPont Tyvek StuccoWrap , DuPont Flashing Systems and DuPont Tyvek Wrap Caps. Caliper • Total – 3.0 mil • Adhesive – 1.6 mil • Backing – 1.4 mil ™ ® ™ ™ ™ ® ™ ® ® ® ™ Our Specialist Network The DuPont Tyvek Specialist Network is an elite team of more than 180 highly-trained field representatives, including 30 who are focused specifically on commercial building applications. From the latest updates on building codes, to keeping up with current trends and challenges, your local DuPont Tyvek Specialist can provide on-site consulting and training to help make sure the job gets done right. ™ ® ™ Adhesion ™ ® ® • Wet grab – 50 oz/in. • Peel adhesion – 40 oz/in. (ASTM D3330) 180 degree peel adhesion (oz/in.) Immediately DuPont Tyvek ™ After 72 hr dwell 24.0 ® 35.0 (Fiber pull off from DuPont Tyvek ) ™ Polyethylene 16.0 Stainless steel 40.0 ® 20.0 Temperature resistance Will withstand temperature extremes from -40°F to 220°F Pliability No cracking when bent around 5 mm mandrel @ -4°F. Moisture Vapor Transmission Rate (MVTR @ 100°F and 90% Relative Humidity) 0.3 g/100 in /24 hr. 2 Stock sizes and packaging Product Case pack Unit weight Outside case dimensions 2.82" x 54.6 yds bulk pack 24 rolls 12.3 oz 13" x 9" x 12" 3" tape dispenser 20 dispensers 16.6 oz 22" x 14" x 19" For more information, please call 1-800-44-Tyvek or visit www.Construction.Tyvek.com Copyright © 2007 DuPont. The DuPont Oval Logo, DuPont , The miracles of science , CommercialWrap , StuccoWrap , and Tyvek are trademarks or registered trademarks of E.I. du Pont de Nemours and Company or its affiliates. All rights reserved. K-16156 2/07 ™ ™ ® ® ® DuPont Commercial Fasteners Building Science Bulletin DuPont Tvyek Wrap Cap screws for commercial steel stud applications ™ ® DuPont Tyvek Wrap Caps with full drill point steel stud screws are designed to provide optimal holding power when securing DuPont Tyvek weather barriers to steel studs in commercial buildings. ™ ® ™ ® Features and benefits 2" DuPont Tvyek Wrap Caps • Constructed of high-density polyethylene with UV inhibitors • Increases fastener holding power, reducing the potential for job-site blow-off of weather barrier • Provides additional protection around fastener penetrations • Offers easy handling and installation ™ DuPont Tyvek Wrap Cap screws provide optimal holding power when securing weather barriers to steel studs. ™ ® DuPont Tyvek Wrap Caps increase holding power and provide additional protection around fastener penetrations. ™ ® ® 1¾" steel stud screw • Self-tapping drill point screw • Coated with an organic fluoropolymer for improved rust protection • Can be applied by hand or drill • Core-attached to DuPont Tyvek Wrap Caps for quick installation • Drill bit included in each box for ease of installation ™ ® Product specifications DuPont Tyvek Wrap Cap screws ™ ® Cap diameter Cap material Cap color Application Screw Box count Box weight Box dimensions 2" high-density polyethelene w/UV inhibitors white hand or drill #8 shank; 1¾" length; coated galvanized steel; modified truss head; Phillips draw 2000 14.5 lbs 12" x 12" x 14" Recommended fastener spacing and negative wind load resistance according to ASTM E330* 2" diameter DuPont Tyvek Wrap Cap screws ™ ® fastener spacing allowable pressure 12" 70 psf 18" 45 psf *Values presented are maximum allowable pressures. A factor of safety may need to be applied for certain claddings. Complete system of products For optimal protection on all your building projects, use DuPont Tyvek Wrap Caps with DuPont Tyvek Weather Barrier Systems including DuPont Tyvek CommercialWrap , DuPont Tyvek StuccoWrap , DuPont Flashing Systems and DuPont Tyvek Tape. ™ ® ™ ™ ™ ® ™ ® ® ® ® ® ™ Our Specialist Network The DuPont Tyvek Specialist Network is an elite team of more than 180 highly-trained field representatives, including 30 who are focused specifically on commercial building applications. From the latest updates on building codes, to keeping up with current trends and challenges, your local DuPont Tyvek Specialist can provide on-site consulting and training to help make sure the job gets done right. ™ ® ™ ® For more information, please call 1-800-44-Tyvek or visit www.Construction.Tyvek.com Copyright © 2007 DuPont. The DuPont Oval Logo, DuPont , The miracles of science , CommercialWrap , StuccoWrap , and Tyvek are trademarks or registered trademarks of E.I. du Pont de Nemours and Company or its affiliates. All rights reserved. K-16154 2/07 ™ ™ ® ® ® DuPont Weatherization Products 10-Year Limited Warranty DuPont Weatherization Products 10-Year Limited Warranty for Multi-Family, Mixed Use and Light Commercial Buildings Over Four Stories: When you specify DuPont Weatherization Systems products, you know that they’re backed by a company that for over 200 years has been dedicated to providing sustainable solutions for a better, safer and healthier life for people everywhere. Peace of Mind: Backed by a 10-Year Limited Warranty from DuPont With 9 months of UV resistance, the ability to withstand wind gusts up to 190 mph, and excellent air and water hold-out, DuPont Tyvek CommercialWrap and DuPont Tyvek CommercialWrap D are designed to meet the unique needs of your commercial project. The use of DuPont Weatherization Products combined with the DuPont Weatherization Products 10-Year Limited Warranty for buildings over four stories helps provide you added assurance that your commercial buildings will protect the owner’s valuable investment for years to come. ™ ™ ® ® ® ® We stand behind you Product and Labor Warranty: When you install all required products according to the applicable DuPont Installation Guidelines and follow the Project Registration and Observation Process outlined on this page, DuPont will provide you with replacement product and reasonable labor costs in the event that the materials do not meet specified air and water hold-out criteria. A DuPont Tyvek Specialist is available throughout the installation process to provide assistance and training. ™ ® Product Warranty: Install our products on buildings over four stories in height and DuPont will provide you with replacement product in the event that the materials do not meet specified water hold-out criteria. If you would like assistance or training, a DuPont Tyvek Specialist is available throughout the installation process. ™ ® For complete warranty details, terms and conditions, visit www.construction.tyvek.com or talk to your local DuPont Tyvek Specialist to ensure you meet the requirements of the warranty coverage you want. Only DuPont may vary the terms and conditions of this warranty. ™ Project Registration and Observation Process for the 10-Year Product and Labor Limited Warranty for DuPont Weatherization Products 1. Specify all DuPont Weatherization Products covered by the DuPont Weatherization Product 10-Year Product and Labor Limited Warranty. 2. Complete the first page of the Project Registration and Observation Form and submit to your DuPont Tyvek Specialist to obtain a Project Tracking Number. ™ ® 3. Arrange a pre-job meeting to include: Architect/architect’s representative, Owner/owner’s representative, General Contractor/ Builder, Professional Installer and DuPont Tyvek Specialist. Review and follow applicable installation guidelines, warranty terms and conditions, and Project Registration and Observation Form. ™ ® 4. DuPont Tyvek Specialist arranges site visit, views installation of DuPont Weatherization Products, completes Project Registration and Observation Form. Professional installer signs Project Registration and Observation Form acknowledging the requirements of the warranty process and terms and conditions. ™ ® 5. At project completion, DuPont Tyvek Specialist provides copy of completed Project Registration and Observation Form and DuPont Weatherization Products 10-Year Limited Warranty document to all relevant parties. ™ ® ® Products Covered Weather Resistive Barriers Flashing* DuPont Tvyek CommercialWrap DuPont Tvyek CommercialWrap D ™ ® ™ ® ® ® DuPont DuPont DuPont DuPont DuPont ™ ™ ™ ™ ™ For more information visit www.Construction.Tyvek.com or call 1-800-44-Tyvek StraightFlash StraightFlash VF FlexWrap FlexWrap NF Thru-Wall Flashing ™ ™ ™ ™ *Note: In order to receive a Product & Labor Warranty on DuPont Flashing Systems products, a DuPont Tyvek Weather-Resistive Barrier must also be installed on the building. ™ ® While our commercial products are designed to meet the needs of the commercial market, DuPont does offer warranty options for our residential products when used on commercial buildings over four stories in height. Talk to your DuPont Tyvek Specialist for details. ™ ® Copyright © 2009 DuPont. The DuPont Oval Logo, DuPont™, CommercialWrap , FlexWrap™, StraightFlash™ and Tyvek are trademarks or registered trademarks of E.I. du Pont de Nemours and Company or its affiliates. All rights reserved. K-17993 04/09 ® ® DuPont Weatherization Products 10-Year Limited Warranty DuPont Weatherization Products 10-Year Limited Warranty for Multi-Family, Mixed Use and Light Commercial Buildings UNDER FIVE STORIES: When you specify DuPont Weatherization Systems products, you know that they’re backed by a company that for over 200 years has been dedicated to providing sustainable solutions for a better, safer and healthier life for people everywhere. Peace of Mind: Backed by a 10-Year Limited Warranty from DuPont With 9 months of UV resistance, the ability to withstand wind gusts up to 190 mph, and excellent air and water hold-out, DuPont Tyvek CommercialWrap and DuPont Tyvek CommercialWrap D are designed to meet the unique needs of your commercial project. The use of DuPont Weatherization Products combined with the DuPont Weatherization Products 10-Year Limited Warranty for buildings under five stories helps provide you added assurance that your commercial buildings will protect the owner’s valuable investment for years to come. ™ ™ ® ® ® ® We stand behind you Product and Labor Warranty: When you install all required products according to the applicable DuPont Installation Guidelines and follow the Project Registration and Observation Process outlined on this page, DuPont will provide you with replacement product and reasonable labor costs in the event that the materials do not meet specified air and water hold-out criteria. A DuPont Tyvek Specialist is available throughout the installation process to provide assistance and training. ™ ® Product Warranty: Install our products on buildings less than five stories in height and DuPont will provide you with replacement product in the event that the materials do not meet specified water hold-out criteria. If you would like assistance or training, a DuPont Tyvek Specialist is available throughout the installation process. ™ ® For complete warranty details, terms and conditions, visit www.construction.tyvek.com or talk to your local DuPont Tyvek Specialist to ensure you meet the requirements of the warranty coverage you want. Only DuPont may vary the terms and conditions of this warranty. ™ Project Registration and Observation Process for the 10-Year Product and Labor Limited Warranty for DuPont Weatherization Products 1. Specify all DuPont Weatherization Products covered by the DuPont Weatherization Product 10-Year Product and Labor Limited Warranty. 2. Complete the first page of the Project Registration and Observation Form and submit to your DuPont Tyvek Specialist to obtain a Project Tracking Number. ™ ® 3. Arrange a pre-job meeting to include: Architect/architect’s representative, Owner/owner’s representative, General Contractor/ Builder, Professional Installer and DuPont Tyvek Specialist. Review and follow applicable installation guidelines, warranty terms and conditions, and Project Registration and Observation Form. ™ ® 4. DuPont Tyvek Specialist arranges site visit, views installation of DuPont Weatherization Products, completes Project Registration and Observation Form. Professional installer signs Project Registration and Observation Form acknowledging the requirements of the warranty process and terms and conditions. ™ ® 5. At project completion, DuPont Tyvek Specialist provides copy of completed Project Registration and Observation Form and DuPont Weatherization Products 10-Year Limited Warranty document to all relevant parties. ™ ® ® Products Covered Weather Resistive Barriers DuPont DuPont DuPont DuPont DuPont DuPont ™ ™ ™ ™ ™ ™ Tvyek Tvyek Tvyek Tvyek Tvyek Tvyek ® ® ® ® ® ® Flashing* CommercialWrap CommercialWrap D HomeWrap StuccoWrap DrainWrap ThermaWrap ® ® ® ® ™ ™ DuPont DuPont DuPont DuPont DuPont DuPont DuPont DuPont ™ ™ ™ ™ ™ ™ ™ ™ For more information visit www.weatherization.tyvek.com or call 1-800-44-Tyvek StraightFlash StraightFlash VF StraightFlash OS FlexWrap FlexWrap NF FlexWrap RW Flashing Tape Thru-Wall Flashing ™ ™ ™ ™ ™ ™ *Note: In order to receive a Product & Labor Warranty on DuPont Flashing Systems products, a DuPont Tyvek Weather-Resistive Barrier must also be installed on the building. ™ ® Copyright © 2009 DuPont. The DuPont Oval Logo, DuPont™, CommercialWrap , DrainWrap™, FlexWrap™, HomeWrap , StraightFlash™, StuccoWrap , ThermaWrap™ and Tyvek are trademarks or registered trademarks of E.I. du Pont de Nemours and Company or its affiliates. All rights reserved. K-17993 10/10 ® ® ® ®