COSY WALL HEATER - Coonara
Transcription
COSY WALL HEATER - Coonara
A Great Way To Keep Warm COSY WALL HEATER The most powerful High Efficiency Wall space heater Customer Operating Information & Installation Instruction Serial Number of Heater: ____________ Model: ___________________ Cosy Gas Wall Heaters ARE AUSTRALIAN OWNED & MANUFACTURED BY SHAMIC SHEETMETAL (AUST.) PTY. LTD. PO BOX 8, KILSYTH, VIC. 3136 PH: 03 9737 5300 FAX: 03 9761 6455 https://shamic.com Revised: 08/08/16 1 8/08/2016 CONTENTS PRODUCT FEATURES…………………………………………………3 SAFETY PRECAUTIONS………………………………………………4 CUSTOMER OPERATING INSTRUCTIONS………..………………5-7 INSTALLATION INSTRUCTIONS……………………………………8-11 INSTALLATION OPTIONS…………………..………………………..12-15 GAS VALVE ADJUSTMENT…………………………………………..16 TROUBLE SHOOTING GUIDE………………………………………..17 DIMENSIONS FOR THE INSTALLER……………………..………....18 WIRING DIAGRAM……………………………….…………………….19 CARE OF APPLIANCE & WARRANTY……………………..………..20 WARRANTY INFORMATION……………………………………..…...21-23 PLEASE STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE Revised: 08/08/16 2 8/08/2016 Product Features COONARA COSY WALL GAS HEATER NAME PLATE MODEL WALLHEATER Manufacturer NATURAL GAS LP / ULP GAS MODEL TYPE Wall Heater Wall Heater Shamic Sheetmetal (Aust.) Pty.Ltd. GAS INPUT HIGH LOW 32 MJ/h 20.5 MJ/h 31 MJ/h 17.1 MJ/h PO BOX 8, KILSYTH, VIC. 3136 GAS TYPE HEAT OUTPUT HIGH 7.7 kW LOW 4.4 kW Efficiency 85.4 % Injector Size 2.8 mm Manifold Pressure High 0.80 kPa Low 0.40 KPa A.G.A Approval No. to Code AS AGA 7759 G AS4553-2008 Electrical Conform to AS3100 Air Pressure Switch Cut in Pressure 7.6 kW 4.4 kW 85.0 % 1.6 mm 2.60 kPa 0.75 KPa To be installed by an authorised person in accordance with installation instructions provided with the appliance. AGA 7759 G 240V 50 Hz 120 Watts Max Cleveland NS2-1184-00 130 Pa Cut out Pressure 120 Pa Electrical Connection Standard Flex. 2 Mt. 3 Pin Plug ENERGY RATING 5.02 STARS POWER FLUED ZERO CLEARANCES TO COMBUSTIBLE WALLS AUTOMATIC ELECTRONIC IGNITION MANUAL TOUCH CONTROLS MODULATED HEAT SETTINGS 3 FAN SPEEDS EXTERNAL COMBUSTION AIR PREVENTS DE-OXYGENATION OF ROOM AIR DELAYED START FAN PREVENTS COLD AIR BEING CIRCULATED AT START UP Revised: 08/08/16 3 8/08/2016 SAFETY PRECAUTIONS ! DO NOT – OPERATE THIS APPLIANCE BEFORE READING THIS INSTRUCTION MANUAL. DO NOT – PLACE ARTICLES ON OR AGAINST THIS APPLIANCE. DO NOT – STORE CHEMICALS, FLAMMABLE MATERIALS OR SPRAY AEROSOLS NEAR THIS APPLIANCE DO NOT – OPERATE WITH PANELS, COVERS OR GUARDS REMOVED FROM THIS APPLIANCE. DO NOT – ENCLOSE THIS APPLIANCE. DO NOT – MODIFY THIS APPLIANCE. DO NOT – PLACE ANY ITEM CONTAINING LIQUID ON THE APPLIANCE THIS APPLIANCE SHALL ONLY BE INSTALLED BY AN AUTHORISED PERSON IN ACCORDANCE TO AS 5601 (GAS INSTALLATION STANDARD) MANUFACTURER’S INSTALLATION INSTRUCTIONS LOCAL GAS FITTING REGULATIONS AND MUNICIPAL BUILDING CODES WARNING: This appliance must be installed to comply to AS/NZS 5601/1.1 2010 codes and regulations and only by an authorised person who is responsible for its correct operation at the time of installation and final commissioning. After completion of installation, it is the installer’s responsibility to ensure that the heater is operating in accordance with the manufacturer’s specifications. Before leaving, the installer must inform and demonstrate to the user the basic instructions for normal operation of this appliance. DO NOT MODIFY THIS APPLIANCE Revised: 08/08/16 4 8/08/2016 Customer Operating Instructions The Coonara Cosy Wall Gas Space Heater has been designed for a simple and efficient operation to provide you with a higher heat output than any other wall heater on the market. With the single touch of a button your heater will provide you with a fully controlled modulated supply of heat, from pleasant and steady warmth to the strongest heat output, to reach almost any corner of your home. PRE OPERATION CHECKS Prior to operating the heater ensure that the flue terminal is not obstructed. Furthermore, make sure there are no combustible objects leaning against, resting on or within the immediate vicinity of the unit. Check that the heater main power and gas supply are connected and switched on. OPERATING THE HEATER The heater is operated by a manual touch pad located at the top left hand corner of the front panel. The operation of the buttons is described in the picture below: 1. To ignite your heater press the ON/OFF Button and the heater will automatically start the ignition sequence. After approximately 30 seconds of self checking, the heater will ignite. 2. The heater always starts in the low heat setting. The heater will warm-up for at least 2 minutes before automatically going to the required heat setting. 3. The fan will not start until the heater has reached the minimum operating temperature of approximately 40C is reached. Note: For maximum performance and by factory default, in any heat setting, the fan speed will always automatically match the selected heat output. Revised: 08/08/16 5 8/08/2016 TURNING THE APPLIANCE OFF Press the ON/OFF Button once. The room fan will continue to operate for a short period while the heater cools down. PLEASE NOTE: 1. This appliance can not be operated without the fan running 2. Due to the performance and efficiency of the heater, steam may be noticed coming from the flue terminal on cool days 3. When starting the heater for the first time an odour may be noticed for a short period as the paint cures. It is advisable to leave the windows open during the first few hours of the very first operation only. SAFETY PRECAUTIONS IMPORTANT POINTS ! DO NOT ! DO NOT ! DO NOT ! DO NOT ! ALWAYS place articles or clothing on or against this appliance use or store flammable materials near this heater place any item containing liquid on the heater spray aerosol in the vicinity of this appliance when it is in operation supervise young children near the appliance NOTE: In the event the electricity supply cord is damaged it must be replaced with the original Coonara part obtainable from your authorised dealer. SAFETY FEATURES: Automatic Pre-purge: This operation is done before heater ignition to remove any remains of gas or flue products that could cause a mishap from inside the heat exchanger. Automatic Shut-off: Should the flame extinguish for any reason there is an automatic shut off of the gas supply. Over temperature protection: In the event of the room fan failing, blockage of airways, or incorrect gas installation, the gas supply will automatically shut off to prevent the appliance from over-heating. WARNING: This appliance must be installed to comply to AS/NZS 5601/1.1 2010 codes and regulations and only by an authorized person who is responsible for its correct operation at the time of installation and final commissioning. Revised: 08/08/16 6 8/08/2016 For your own convenience record the following information in the space provided: Purchased from: Name…………………………………………………………………………………… Address………………………………………………………………………………… Phone No…………………………………..Date of purchase …………..…………. Serial No of appliance………………………………………………………………… To be completed by the installer: Name……………………………………………..License No………………………... Address………………………………………………………………………………… Phone No……………………………………. Installation Date…………………….. Revised: 08/08/16 7 8/08/2016 INSTALLATION: ONLY TO BE CARRIED OUT BY AN AUTHORISED PERSON! The Coonara Cosy Wall Heater, being a zero clearance appliance, can be installed in a wall cavity made of combustible materials such as wood or chipboard. Coonara provide the heater with their own flue kit of flexible pipes of 50mm diameter for the inlet and exhaust. For the gas supply a flexible stainless steel hose is provided and must be used. BOTH ENDS OF FLEXIBLE FLUE PIPE MUST BE SEALED AND CLAMPED. This easy access connection system allows the heater to be quickly serviced by one person. This heater does not need to be removed to service and maintain items such as the room fan, electronic components, etc. To service these items follow the steps below: 1. Remove the front bottom panel by undoing one screw and pulling the panel outwards, towards you from top edge. This will release the Pull Push spring studs. 2. Remove the centre panel by undoing the 3 screws and pulling the panel outwards, towards you from top edge. This will release the Pull Push spring studs. WARNING: ON REASSEMBLY, TO STOP OVER HEATING OF UNIT, THESE 3 SCREWS MUST BE REPLACED. 3. Remove large front panel by undoing 2 screws under bottom edge and pulling the panel outwards, towards you from top edge. WARNING: THE TOUCH PAD ON THIS FRONT PANEL IS STILL CONNECTED TO THE LOOM. TOUCH PAD NEEDS TO BE DISCONNECTED BEFORE COMPLETELY REMOVING THE PANEL. 4. To take off left hand side panel for service, remove 3 buttons from top left hand side and 3 from bottom left hand side. This allows removal of screws. Slide the bottom of left hand side panel to the left. TO REASSEMBLE: 1. Once side panels are in position and screwed to top and bottom panel, the large front panel is then put into place and screwed into position with 2 screws. 2. Clip bottom front panel and screw into position with 1 screw. 3. Clip middle front panel into position screw into position with 3 screws. Revised: 08/08/16 8 8/08/2016 Revised: 08/08/16 9 8/08/2016 Revised: 08/08/16 10 8/08/2016 INSTALLATION OPTION 1: ROOF PENETRATION CONCEAL FLUE PIPES IN WALL CAVITY USING SHAMIC VERTICAL FLUE KIT Revised: 08/08/16 11 8/08/2016 INSTALLATION OPTION 2: ROOF PENETRATION CONCEAL WITH WALL COVER BOX AND SHAMIC VERTICAL FLUE KIT Revised: 08/08/16 12 8/08/2016 INSTALLATION OPTION 3: EXTERNAL WALL PENETRATION WITH SHAMIC HORIZONTAL FLUE KIT. Revised: 08/08/16 13 8/08/2016 INSTALLATION OPTION 4: INTERNAL WALL ON STUMP FLOOR AND WALL PENETRATION UNDER THE FLOOR WITH SHAMIC HORIZONTAL FLUE KIT. Revised: 08/08/16 14 8/08/2016 Gas Valve Pressure adjustment. Your Coonara Wall Heater has been factory preset and does not need to be readjusted during installation. But there will be some situations where some service has to be carried out and gas pressure may need to be readjusted as per following Instructions: Revised: 08/08/16 15 8/08/2016 TROUBLESHOOTING GUIDE PROBLEM Appliance fails to ignite. POSSIBLE CAUSE REMEDY No gas or supply pressure insufficient. Ensure gas supply connected, purged, and pressure appropriate. No electrical supply. Ensure unit plugged in and switch is on, check supply fuse. Check supply. Active, neutral, & earth must be correctly orientated and connected. Incorrectly wired power point. Incorrect gas valve adjustment. Adjust valve pressures. Insufficient time allowed between attempts. Wait at least 30 seconds for unit to purge combustion chamber after switching on. Internal wiring disconnected. Check all plugs inside appliance are connected properly and correctly located, Ensure operation of combustion fan & air pressure switch. Unit will not operate on Low. Incorrect gas valve adjustment. Adjust valve. Incorrect or loose wiring. Check wiring. Room fan not operating. Insufficient time allowed. Loose wiring. Fan has a delayed start and will not start until unit warms-up. Check wiring. Fan not located correctly. Install fan in correct location. Fan blocked. See “Room fan not operating” Remove and clean fan. See “Room fan not operating” Heat exchanger blockage. Clean heat exchanger. Excessive pressure or incorrect gas type. Incorrect gas type or pressure setting. Ensure correct gas type, injector size, and pressure setting. Ensure correct gas type, injector size, and pressure setting. Excessive flame height. Incorrect gas type or pressure setting. Ensure correct gas type, injector size, and pressure setting. Excessive flame “lift off” Flue or inlet blockage. Clear blockage. Recirculation of flue gases. See “Room fan not operating” Flue incorrectly installed. See “Room fan not operating” Incorrect gas type or pressure setting. Ensure correct gas type, injector size, and pressure setting. Unit cuts out after a period of time then cycles on and off. Excessive carbon (soot) deposits inside of Flue and firebox. Unit fails to heat. Gas supply blockage. Check injector, burner supply pipe, & valve for foreign matter. All service work to be carried out by a qualified & authorised person. Revised: 08/08/16 16 8/08/2016 DIMENSIONS OF APPLIANCE FOR THE INSTALLER For ease of installation a fixing template can be found marked on the inside bottom of the carton. Revised: 08/08/16 17 8/08/2016 Wiring diagram: Revised: 08/08/16 18 8/08/2016 CARE OF YOUR COONARA COSY WALL HEATER This appliance requires minimal maintenance however, it is recommended that a full service and check be made by a qualified person annually. The fan is to be vacuumed at this time. To carry out this service the Bottom panel air grill should be removed as follows: 1. Remove the front bottom panel by undoing one screw and pulling the panel outwards, towards you from top edge. This will release the Pull Push spring studs. 2. Remove the centre panel by undoing the 3 screws screw and pulling the panel outwards, towards you from top edge. This will release the Pull Push spring studs. WARNING: ON REASSEMBLY, TO STOP OVER HEATING OF UNIT, THESE 3 SCREWS MUST BE REPLACED. To clean the appliance, simply wipe over with a damp cloth. Do not use solvents or abrasive cleaning agents. WARNING: DO NOT use the heater without the middle panel being properly fitted and screwed in place with 3 screws. If the middle panel is not fitted correctly the appliance will overheat and this will void the warranty. WARRANTY As a purchaser of this Coonara product, Shamic Sheetmetal (Aust.) Pty.Ltd. provides you with the following warranty: Heat Exchanger ___________10 Year _____________2 Year free labour All other Parts____________ 2 Year _____________2Year free labour This Warranty is in addition to all other rights and remedies, which the purchaser may have under statute. Revised: 08/08/16 19 8/08/2016 How to Make a Warranty Claim Coonara, Heatcharm, Arrow and Settler Heaters. The full Warranty Statement for your heater is contained in the Installation and Operating Instructions booklet that was provided with the product. 1. Check the details of the warranty statement 2. Determine if you think the problem is covered by warranty 3. Ensure that you have proof of purchase 4. Contact the retailer that sold you the heater 5. Advise them of the specific problem 6. Provide the details that your retailer requests to complete a Warranty Claim Form. This must include the heater model, serial number and installation compliance certificate, if applicable in your State. 7. Your retailer will forward your claim to Shamic Sheetmetal (Aust) Pty Ltd, the manufacturer of the above heater brands 8. Shamic will contact you to acknowledge that they have received the claim, if the claim has been accepted and the next steps involved in fixing the problem 9. Parts and/or service is provided 10. Contact your retailer if the problem has not been fixed. Revised: 08/08/16 20 8/08/2016 WARRANTY DESIGNATION OF WARRANTOR. This warranty is extended by Shamic Sheetmetal (Aust) Pty. Ltd with respect to Coonara gas heaters PRODUCT. Except where specifically excluded from coverage hereunder, this warranty covers all components designed. See exclusions and qualifications below for further information on product coverage. WARRANTY: 1) Shamic Sheetmetal (Aust) Pty. Ltd warrants the heat exchanger to be free of defects in materials and workmanship of a period of five (5) years from the date of purchase. 2) Shamic Sheetmetal (Aust.) Pty.Ltd. warrants that all other components of the unit to be free of defects in material and workmanship for a period of two (2) years from date of purchase, excluding door glass and decorative logs. 3) If this Coonara heater is found to be defective in material or workmanship Shamic will repair or replace such defects in the Coonara heater at Shamic’s option in accordance with Coonara’s warranty policy during the period on this warranty. If the defect is found not to meet the Consumer Guarantee requirements and constitutes a major failure, the purchaser may be able to choose to repair or replace the defective heater or part or obtain a refund. 4) Exclusions and qualifications. This warranty is subject to the following exclusions and qualifications. a) This warranty extends only to the original consumer purchaser, who has purchased the heater from an authorised Coonara dealer. b) This warranty does not apply to, and Coonara assumes no responsibility for any damages that result due to, installation or operation of the heater not in accordance with both the installation and operation instructions furnished with the unit. c) This warranty does not apply to any heater which has been modified or damaged in shipping or by improper handling, improper operation, abuse, misuse, accident or unworkmanlike repairs. d) Shamic Sheetmetal (Aust.) Pty.Ltd. does not warrant the structural performance of the heater when fuel products other than the specified gas fuels are used. Flammable liquid fuels are explosive and should never be used in this product. e) Shamic Sheetmetal (Aust.) Pty.Ltd. expressly excludes any liability hereunder for defects or damage caused by the installation or of any components not expressly authorised and approved by Shamic. Shamic further assumes no liability for defects or damage caused by any modification not expressly authorised and approved by Shamic. Unauthorised components or modifications could create a fire hazard by altering the safety design of the heater. f) Building Codes. Since building code requirements vary, users should determine in advance whether there are any building code restrictions on the installation or use of the heater. Shamic makes no representation of warranty regarding building code compliance and shall not be responsible for compliance therewith. g) Shamic will only accept claims under this warranty in strict accordance with the conditions set out below. 5) Shamic Sheetmetal (Aust.) Pty.Ltd. shall not be liable for any breakages of glass and log components, transit damage or, where it can be shown that the consumer guarantee obligations as the manufacturer have been met, for any claim by any person for incidental or consequential damages caused by defects in the Coonara heater. Whether such damage occurs or is discovered before or after replacement or repair, and whether or not such damage is caused by Coonara negligence. Normal wear and tear items such as routine surface maintenance, seals and door glass are also excluded from this warranty. 6) Shamic goods come with guarantees that cannot be excluded under Australian Consumer Law. The purchaser is entitled to a replacement or a refund for a major failure and compensation for any reasonably foreseeable loss or damage. The purchaser is also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. 7) This warranty applies only to units purchased from an authorised dealer and the duration of this implied warranty, including merchantability, applicable to this Coonara heater is limited to the duration of the foregoing warranty. 8) Before Shamic Sheetmetal (Aust.) Pty.Ltd. will recognise or accept a claim under this warranty, you must provide proof of purchase. On purchase of the heater, despatch your warranty card to Shamic Sheetmetal (Aust.) Pty.Ltd. 9) Your authorised dealer must be notified of any defect in the heater, for investigation of the claim. Your authorised dealer will be able to explain the process of making a warranty claim and any costs associated with returning goods. In the event where a remedy is necessary and the claims under warranty are accepted, the purchaser may be required to return the goods to the authorised dealer for repair, replacement or refund. Revised: 08/08/16 21 8/08/2016 Revised: 08/08/16 22 8/08/2016 For your nearest authorised service company, please contact: SHAMIC SHEETMETAL (AUST.) PTY. LTD. HEAD OFFICE: 14 – 18 Research Drive, CROYDON SOUTH, VIC. 3136 POSTAL ADDRESS: P.O. Box 8, KILSYTH, VIC. 3137 Phone: (03) 9737 5300 Fax: (03) 9761 6455 Email: info@shamic.com.au COONARA COSY WALL HEATER WARRANTY DETACH AND RETURN BY MAIL NAME ________________________________________________________________ ADDRESS _____________________________________________________________ CITY / STATE / POSTCODE ______________________________________________ PURCHASED AT (Dealer name & address) __________________________________ DATE PURCHASED __________ MODEL __________________ SERIAL NO _____ WHERE DID YOU HEAR ABOUT COONARA COSY WALL HEATERS? RADIO, TELEVISION, NEWSPAPER, – please provide details below. DEALER, WEBSITE, OTHER ________________________________________________________________________ Revised: 08/08/16 23 8/08/2016