Flextray NEW Catalog 02/04 Q
Transcription
Flextray NEW Catalog 02/04 Q
welcome to flextray welcome to flextray This Cable Management System is the time and money saving alternative to traditional cable tray systems. FLEXTRAY’s innovative steel mesh design enables faster installation with less labor and materials. The open mesh design enables cable networks to be expanded quickly and easily – it is ideal for today’s sensitive telecommunications and fiber optic cables. FLEXTRAY is available in a variety of finishes and depths of 11/2”, 2”, 4” and 6”. Widths range from 2” to 34” to meet your cabling needs. Installation of the FLEXTRAY Cable Management System is simple. A CLEANSHEAR® Cutter and installation tool are all that’s needed. And, with FLEXTRAY’s complete line of accessories and mounting options – you can easily navigate any environment. THICKEST GAUGE METAL FLEXTRAY minimum 5mm gauge steel is at least 30% stronger than competitor’s lesser gauge steel. BUILT-IN SAFETY “T” weld safety edge construction eliminates sharp edges -avoiding injury to hands and damage to cable. www.flextray.com 1 table of contents 2 where to use flextray UL Classified 4 flextray straight sections Flextray meets all applicable UL standard requirements regarding tray used as an equipment ground conductor. See page 5 on Flextray sizes that meet these standards. CSA Approved (Canadian Standards Association) FLEXTRAY is an approved cable management system for supporting communications and optical fiber cables. FLEXTRAY complies with T.I.L. No. J-26 prepared by CSA, and was formally approved by the subcommittee on CSA Standard C22.2 No. 126. Sizes, Finishes, Load & Fill Tables, UL classified sizes 6 Bolted, Flexmate, Spring Splice, Coil Splice, UL Splice Information 8 Union Made Flextray is made by United Steel Workers Union – Local 7252 Safe Only FLEXTRAY offers clean, smooth burr-free cuts every time with CLEANSHEAR Cutters. Our “T-weld” design allows easy side loading of cable without damaging cable or hands. Union Made in the USA support methods Ceiling types, Wall types, Underfloor types 13 accessories Drop-outs, Rack Attachments, Hold Down Clips, Dividers, Covers, Solid Bottom Inserts Conduit Fitting Attachments, Grounding Accessories 16 hardware Ceiling Anchors, Threaded Rod, Nuts, Washers, Beam Clamps, Metal Framing, Spring Nuts 18 flextray convenience kits FlexPack, Rack Pack Made in the USA Flextray is the only wire mesh cable tray fully constructed in the U.S.A. splice methods 19 RF raised floor system RF components and accessories 23 cutting tools Cleanshear, Cleanshear with Bending Attachment, AirShear 25 creating fittings Making Horizontal Bends, Making Tees, Making Crosses, Making Vertical fittings 32 design/technical tools 33 CSI specification 33 index Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com table of contents flextray is… 2 where to use flextray where to use flextray Ceiling and Plenum Spaces FLEXTRAY Cable Management System installs in plenum applications faster and with greater flexibility than standard tray. Installers can bend, curve, drop or avoid any obstacle -- adjustments can be made on-site without delays. www.flextray.com 3 where to use flextray Raised Access Floors Today’s computer environment requires a cable management system that supports today’s sophisticated cables and can quickly be expanded for additional runs -FLEXTRAY Cable Management System meets all these requirements. Telecommunication Closets FLEXTRAY‘s open ventilated steel mesh design provides endless locations to secure cable and enables easy identification. FLEXTRAY’s many parts, widths and depths make organizing the closet simple. Union Made in the USA Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com 4 straight sections Flextray straight sections come in 10’ lengths. These are the main components to your pathway installation. straight sections Make straight runs, horizontal and vertical changes from these sizes: FLEXTRAY PART # 2 inch depth 4 inch depth 6 inch depth Depth Width lbs/ea FT2X2X10 2 2 5.9 FT2X4X10 2 4 8.6 FT2X6X10 2 6 10.2 FT2X8X10 2 8 11.8 FT2X12X10 2 12 15 FT2X16X10 2 16 23 FT2X18X10 2 18 25 FT2X20X10 2 20 27 FT2X24X10 2 24 31 FT4x8x10 4 8 16.4 FT4x12x10 4 12 23 FT4x16x10 4 16 27 FT4x18x10 4 18 29.3 FT4x20x10 4 20 31 FT4x24x10 4 24 35 FT4x30x10 4 30 41 FT6x8x10 6 8 23 FT6x12x10 6 12 27 FT6x16x10 6 16 31 FT6x18x10 6 18 33 FT6x20x10 6 20 35 FT6x24x10 6 24 39 Straight sections are stocked in electro-galvanized and BLE (Black Flex-e-coat) finishes. All sizes are nominal. 1.5 inch depth also available. Contact factory for details. www.flextray.com 5 loadchart FLEXTRAY PART# variety of finishes. Stocked in galvanized and Black painted Flex-e-coat, Flextray can also be purchased in any painted color, hot dip galvanized and stainless steel. Electroplated Zinc Galvanizing: Electrodeposited zinc coating applied to an average thickness of 0.7 mils (18 microns) to 0.8 mils (20 microns). This surface treatment is suitable for most indoor applications. 5 FT. 6 FT. 7 FT. *** 8 FT. 9 FT. 10 FT. FILL AREA (sq. in.) Number of Cables 219 FT1.5x12x10 10 8 6 6 5 5 11.8 FT2x2x10 35 30 25 22 18 15 4.2 78 FT2x4x10 17 17 17 16 15 14 8.2 152 FT2x6x10 18 17 16 14 11 9 12.4 230 FT2x8x10 20 19 17 14 12 9 16.6 308 FT2x12x10 31 28 25 20 16 11 24.8 461 FT2x16x10 39 33 27 24 20 16 33.4 620 FT2x18x10 41 36 31 26 20 15 37.6 698 FT2x20x10 45 39 32 26 20 14 41.8 776 FT2x24x10 FT4x4x10 FT4x8x10 FT4x12x10 FT4x16x10 84 23 35 52 68 72 23 35 52 64 60 20 31 52 60 50 18 27 46 50 39 15 22 38 40 29 11 18 29 31 50.2 15.6 31.6 47.2 63.6 932 290 587 877 1181 FT4x18x10 FT4x20x10 68 67 64 58 54 49 44 39 35 30 26 21 71.6 79.6 1330 1478 FT4x24x10 66 52 38 29 20 11 95.6 1775 6” depth loads available - call us for data. **Clear Span of Support (Support Points- lbs/ft) ***Fill Rates – Cables used for fill rate testing is .1852 diameter. FLEXTRAY fill capacity is based on NEC allowable fill of 50%. This rule requires the cable cross-sectional areas added together may not exceed 50% of the tray area (width x depth = fill area). Fill capacities stated are based on typical Cat5 diameters (.1852 dia.) In real world tray installations, cables will near completely fill the cable tray when reaching the 50% cable fill (see illustration below). When the tray is full, the total of the cable area is only 50% of the tray, this is due to empty space between the surface of the cable. Tray Selection is governed by fill rate, not load. Flextray loads, as shown in chart , will not be exceeded before fill capacity - see illustration Special sizes also available. Black FLEX-E-COAT: A 60% gloss with a film thickness of 0.4-1.2 mils capable of withstanding a 90 degree angle bend with a 1/4” radius. This finish is compliant with NFPA 90A, (Plenum Rated), and ASTM B117 for salt spray testing. fill capacity GS Pre-Galvanized Finish: Zinc coated Carbon steel. Pre-galvanized wire before fabrication. This finish is suitable for most indoor controlled environments. ASTM A641. Hot Dip Galvanizing: Provided by immersing the product in a molten zinc bath, this coating is applied to an average thickness of 2.4 mils (60 microns) to 3.2 mils (80 microns). This treatment is most suitable for outdoor applications or situations where increased corrosion resistance is desired. Stainless: Corrosive resistant Stainless Steel with no additional surface treatment. This material option provides the most corrosion resistant option available. Stainless steel is used primarily in marine environments or food processing facilities. Special Colors (E-Coat painted finishes) are available upon request. Union Made in the USA UL classified sizes These sizes of Flextray meet UL requirements regarding use as an equipment ground conductor. FT1.5X12X10 FT2X6X10 FT2X8X10 FT2X10X10 FT2X12X10 FT2X14X10 FT2X16X10 FT2X18X10 FT2X20X10 FT2X22X10 FT2X24X10 FT2X26X10 FT2X28X10 FT2X30X10 FT4X4X10 FT4X6X10 FT4X8X10 FT4X10X10 FT4X12X10 FT4X14X10 FT4X16X10 FT4X18X10 FT4X20X10 FT4X22X10 FT4X24X10 FT4X26X10 FT4X28X10 FT6X8X10 FT6X10X10 FT6X12X10 FT6X14X10 FT6X16X10 FT6X18X10 FT6X20X10 FT6X22X10 FT6X24X10 Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com straight sections Flextray is available in a wide fillchart ** Finishes 6 splice methods Flextray offers Fast and Secure connections to splice straight runs and radius fittings. See note s on pag e 7 for Flexmate UL comp liance. Flexmate is the fastest splice method available. Position connector inside of tool. Squeeze to secure splice. p/n# FLEXMATE TOOL p/n# FLEXMATE (50/bx) HEIGHTS WIDTHS 2 4 6 2 2 - 4 2 5 5 6 3 - 8 3 6 6 Stocked in electro-galv and black finishes. 12 16 18 20 24 4 4 4 5 5 6 7 7 7 8 6 7 7 7 8 Chart illustrates number of splice parts RECOMMENDED for each size of FLEXTRAY. Spring Splice Spring Splice method enable fast connections of continuous runs. for on page 7 See notes L compliance. eU Spring Splic Stocked in electro-galv and black finishes. Splice Washers Washer kits can be used with any application. UL approved method for splicing cable tray. p/n# SPRING SPL (50/BX- includes installation tool) 1/4"-20 X 1" Carriage Bolt (FTHDWE 1/4) WIDTHS HEIGHTS 2 4 6 2 2 - 4 4 5 - 6 4 - 8 4 6 6 1-3/16" Square Splice Washer (BTM WASHER) 12 16 18 20 24 4 4 4 5 6 6 7 7 7 8 6 7 7 7 8 Chart illustrates number of splice parts RECOMMENDED for each size of FLEXTRAY. 1" Square Splice Washer (TOP WASHER) 1/4 " Serrated Nut (FTHDWE 1/4) p/n# WASHER SPL KIT (50/BX) Assemble with wrench WIDTHS HEIGHTS splice methods Flexmate System With two trays end to end, position Spring Splice on the inside of the tray. Pull assembly tool toward you to tighten. Spring Splice will automatically lock into place.Repeat on opposite side. 2 4 6 2 2 - 4 2 5 5 6 3 - 8 3 6 6 Stocked in 12 16 18 20 24 4 4 4 5 5 6 7 7 7 8 6 7 7 7 8 electro-galv and black finishes. Chart illustrates number of splice parts RECOMMENDED for each size of FLEXTRAY. www.flextray.com 7 Splice Bars Splice bars are used on side rails only. They add rigidity to washer splice installations. Use on widths greater than 12 inches. UL approved method for splicing cable tray. WIDTHS Stocked in electro-galv and black finishes. HEIGHTS p/n# Splice Bar (50/bx) 2 4 6 12 16 18 20 24 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 Chart illustrates number of splice parts RECOMMENDED for each size of FLEXTRAY. Splice bars require Top Washer and FTHDWE 1/4 to connect. Order 3x’s number of bars needed. Washer Splice Kit is used for tray bottom splice splice methods Assembled Splice Bar method attaches between two side rails with Top Washers, nuts and bolts. UL Compliance To meet UL compliance, Tray sizes that meet cross-section area requirements by UL must be spliced using “bolted” connectors. Flextray petitioned Underwriters Labs for the inclusion of a single bolted connection, in conjunction with our other splicing options that offer much faster installation options. Flexmate and Spring Splice methods can be used and meet UL requirements by utilizing a bolted splice method on the bottom of the trays or a single GROUND BOLT. Ground Bolt (p. 15) Flexmate with Ground Bolt Spring Splice with Ground Bolt UL grounding requirements are based on cross sectional areas. When removal of wire, such as when horizontal or vertical fittings are created by cutting and removing wires from the tray, this area is effected. Separate grounding methods must therefore be used. Union Made in the USA Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com 8 support methods ceiling types support methods ceiling types Trapeze Support p/n#TRAPEZE SUPT2 (50/BX) After cable is loaded snap in plastic retainer to lock support to tray. Accepts 1/4” & 3/8” threaded rod sizes. Center Hangers NEW! p/n# 4 CTR HGR 6 CTR HGR 8 CTR HGR 12 CTR HGR 16 CTR HGR 18 CTR HGR 20 CTR HGR 24 CTR HGR Position hanger below tray. Lock hanger into place by twisting hanger where tabs are over tray cross wire. Tabs can be bent over wire if needed. Center Hung Clips p/n# CTR HUNG CLP (50/BX) Use Clips for 4” - 8” widths. Accepts 1/4” threaded rod. www.flextray.com 9 support methods 2” Center Supports p/n# 2 IN CTR SUPT (50/BX) C Brackets NEW! improved hold-down tab C Bracket attached to strut or other ceiling type p/n# 4 C BRKT 8 C BRKT 12 C BRKT Combination L and C bracket for layered runs of tray. Profile *All items on these pages are available from stock in electro-galv or BLEBlack finish. Add BLE to suffix of part p/n# 10 LFT PROFILE number for black. Use as a trapeze support for wider runs of tray. Union Made in the USA Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com ceiling types Assemble with ATTACHMENT CLIP (P. 11). Accepts 1/4” threaded rod. 10 wall types support methods wall types Shelf Brackets support methods NEW! p/n# 6 SHELF BRKT 8 SHELF BRKT 12 SHELF BRKT 16 SHELF BRK 18 SHELF BRKT 20 SHELF BRKT 24 SHELF BRKT Shelf Brackets offer heavy duty support. Conduit sizes from 1/4” - 1 1/2” can be supported through shelf brackets. L Brackets NEW! improved hold-down tab p/n# 4 L BRKT 8 L BRKT 12 L BRKT 16 L BRKT 20 L BRKT 24 L BRKT Use L BRKT with PEDESTAL CLAMP Hold down tray with tab or with TOOLLESS CLIP Z Brackets p/n# Z BRKT Use as a vertical support Use Z BRKT to lift tray off floor www.flextray.com 11 support methods Attachment Clip wall types p/n# Attachment Clip (50/bx) Use with 2 IN CTR SUPT (p. 9) Wall support for 2” wide tray Support Washer p/n#SUPT WASHER (50/BX) Use as a hold down Use as center hanger with threaded rod Wall Support p/n# WALL SUPT Use as center hanger with threaded rod Mount to metal framing for vertical support Union Made in the USA Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com support methods underfloor types 12 support methods underfloor types Pedestal Clamps NEW! Use with Shelf BRKT p/n# PEDESTAL CLAMP Use with L BRKT Pedestal Kit Floor Pan p/n# FLOOR PAN 4 FLOOR PAN 6 p/n# PEDESTAL KIT (2 EA PEDESTAL CLAMPS & 1 EA 24” PROFILE, NUTS & BOLTS FOR HOLD DOWN) Available in 18” width. Other heights available. Pedestal Kits provide full 24” support for underfloor applications. Support Flextray independent of other infrastructure. www.flextray.com 13 accessories Straight run drop-out Drop-Outs accessories p/n# 4 IN DROP-OUT 6 IN DROP-OUT Drop Out cable from sides of tray Rack Clamp Toolless Connectors p/n# TOOLLESS CLIP (50/BX) p/n# RACK CLAMP BLE (4/BX) Snap in locking pin secures the tray to support Installs without drilling into rack Union Made in the USA Use TOOLLESS CLIP to hold down tray to supports Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com 14 accessories Dividers accessories Attach Divider with WASHER SPL KIT (p. 6) p/n# 2 IN DIVIDER 4 IN DIVIDER 6 IN DIVIDER Covers p/n# 2 IN COVER 4 IN COVER 6 IN COVER 8 IN COVER 12 IN COVER 16 IN COVER 18 IN COVER 20 IN COVER 24 IN COVER Bend down tabs to secure covers to tray Solid Bottom Inserts p/n# INSERT 2X118 INSERT 4X118 INSERT 6X118 INSERT 8X118 INSERT 12X118 INSERT 16X118 INSERT 18X118 INSERT 20X118 INSERT 24X118 *All items on this page are available from stock in electro-galv or BLEBlack finish. Add BLE to suffix of part Use inserts for solid surface needs. number for black. www.flextray.com 15 Conduit Fittings NEW! Ground Bolts Allows smooth transition from tray to conduit Assembles easily Ground Wire Supports p/n# GROUND SUPT GL (100/BX) p/n# GROUND BOLT Use GROUND BOLT with Spring Splice or Flexmate to meet UL requirements – see page 7 Supports ground wire along side of trays Union Made in the USA Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com accessories p/n# fits conduit size FTEMTDO50 1/2” FTEMTDO75 3/4” FTEMTDO100 1” FTEMTDO125 1 1/4” (comes unassembled) (4/BX) 16 hardware Bottom Mounted Installation hardware Ceiling Anchors Ceiling Rod Anchors allow fast & easy installation of threaded rods to most ceiling types. Anchors for wood, steel or concrete ceilings utilizing 3/8” threaded rods are available. Side or Bottom mounting types makes it convenient for space sensitive installations. 1/4“ and 3/8” rod sizes are available – call factory for price and availability CEILING TYPES WOOD . . . . . . . . WOOD . . . . . . . . WOOD . . . . . . . . WOOD . . . . . . . . STEEL . . . . . . . . STEEL . . . . . . . . STEEL . . . . . . . . STEEL . . . . . . . . STEEL . . . . . . . . CONCRETE . . . . . . (anchors come 50/bx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N# FT3820WDB FT3820WDS FT3830WDB FT38075WDB FT38125STS FT3820STB FT38075STB FT38125STB FT3810STB FT3820CTB Side Mounted Installation SIZE/DESCRIPTION 3/8”X2” BOTTOM MOUNT 3/8”X2” SIDE MOUNT 3/8”X3” BOTTOM MOUNT 3/8 X.75” BOTTOM MOUNT 3/8 X 1.25 SIDE MOUNT 3/8 X 2 BOTTOM MOUNT 3/8 X .75 BOTTOM MOUNT 3/8 X1.25 BOTTOM MOUNT W/NUT 3/8 X 1 BOTTOM MOUNT W/NUT 3/8X2 BOTTOM MOUNT Concrete Installation Extension Pole Tool Eliminate the hassle of building scaffolding or lifts to install your threaded rod TO INSTALL... 1. Cut rod to length, screw ceiling anchor onto rod, and insert rod into pole. 2. In vertical position with drill on working end of pole, center screw on members to be penetrated and begin installation. When drill lags down, check to see if installation is complete. Do not overtorque screw. Pull down on pole and the rod will remain ready to receive your FLEXTRAY Support selection. TOOLS P/N# FTSIDE FTBTM FTPOLE DESCRIPTION NUT DRIVER FOR SIDE MOUNTING ANCHORS NUT DRIVER FOR BOTTOM MOUNTING EXTENSION POLE TOOL www.flextray.com 17 Threaded Rod/Beam Clamps/Hardware Threaded Rod Coupling Nuts Hex Nuts p/n# FT1905 FT1906 FT1907 FT1908 FT1909 FT1910 FT1911 FT1912 FT1913 p/n# FT1859 FT1860 FT1861 (50/BX) p/n# FT1842 FT1843 FT1844 FT1845 (100/BX) size 1/4”-20 3/8”-16 1/2”-13 Lock Washers Finned Nuts p/n# FINNED NUT 1/4 FINNED NUT 3/8 (100/BX) size 1/4”-20 5/16”-18 3/8”-16 1/2”-13 p/n# FT1881 FT1883 FT1884 (200/BX) size 1/4”-20 3/8-16 size 1/4” 3/8” 1/2” Beam Clamp Flat Washers Square Washers p/n# FT6500 FT6502 FT6503 p/n# FT1874 FT1876 FT1877 (200/BX) p/n# FT2003 FT2004 FT2005 (50/BX) size 1/4” 3/8” 1/2” C Clamp p/n# FT6053 FT6054 size 3/8” 1/2” size 1/4” 3/8” 1/2” Swivel Rod Hanger U Bolt Clamp p/n# size FT6061 1/2” p/n# FT6030 Spring Nuts Channel Framing p/n# FT5812SL FT5812SH FT1315SL FT1315SH 1-5/8" p/n# FT1032 SW FT1034 SW FT1035 SW (100/BX) size 1 5/8”X1 5/8” SL – 12 GAUGE – 10’ LENGTHS 1 5/8”x1 5/8”SH – 12 GAUGE – 10’ LENGTHS 13/15”x1 5/8”SL – 15 GAUGE – 10’ LENGTHS 13/15”X1 5/8”SH – 15 GAUGE – 10’ LENGTHS 13/16" 1-5/8" 1-5/8" size 5/16” 3/8” 1/2” size 1/4”-20 3/8”-16 1/2”-13 hole style SL hole style SH Channel framing also available in special pre-cut lengths and colors. Union Made in the USA Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com hardware sizes 1/4”-20 X 6’ 1/4”-20 X 10’ 1/4”-20 X 12’ 3/8”-16 X 6’ 3/8”-16 X 10’ 3/8”-16 X 12’ 1/2”-13 X 6’ 1/2”-13 X 10’ 1/2”-13 x 12’ 18 flextray convenience kits flextray convenience kits Flexpack Convenient pre-packaged Flextray system includes 4 straight sections and hardware for closet or small installations. All sizes contain 7’ lengths that can be shipped FEDX or UPS quickly. p/n# FP2X8X7 FP2X12X7 FP4X12X7 Size 2” H X 8”W 2”H X 12”W 4”H X 12”W *Also available in Black (BLE) finish Rackpack Rackpack offer items you NEW! P/N# RP4X12 BLE RP6x12 BLE SIZE 4”H X 12”W 6”H x 12”W need to organize pathways into racks and closet spaces. Each pack includes one 4’7” (nom.) section of tray, two RACK CLAMPS and one Z BRKT all in the Black (BLE) Finish. Try the convenience of prepackaged, easy to ship Flextray all-inclusive system. www.flextray.com 19 RF raised floor system NEW! Self Supporting – Patented vertical support that does not compromise raised floor support weight limitations or warranties. No Stringer Types to Consider – RF System is not suspended from tile stringers – it is independently supported. Meaning no variables or regulations to consider. UL Classified – All sizes of RF System trays are now UL Listed when connected with ground clip (see page 21). (patent pending) Easy Drop-In Design – RF components are designed to fit 24” Raised Floor designs – just drop through tile space and lock into place – no fastening required. No cutting or splicing needed. Add More RF Easily – Additional runs and layers of RF can be easily added or changed without waste, demolition or lost time. Multiple Tray Sizes – 24, 12 and 6 inch standard sizes. Others available upon request. Computer Centers The RF System’s modular design adapts easily for use with any cabling application. Switch Rooms The New RF System gives you the flexibility you’ve come to expect from Flextray products. This patented design is self-supporting – meaning no floor stringer or stanchion variables to consider. The ease of installation and RF’s design will allow you to re-configure your cable pathways for future expansion. Install vertical supports and lock the horizontal bar into position. You are ready to lay in the tray sections and go. Install Vertical Support Legs Union Made in the USA Lock on the Horizontal Support Bar Drop in Tray Panels Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com RF raised floor system FLEXTRAY’S RF System provides maximum accessibility and flexibility for your raised floor cabling needs: 20 RF raised floor system RF components Flextray’s RF System uses 24’ centered floor support design. This configuration will allow easy retrofit capabilities without compromising the access floor installation. Tray sizes offered will fit into this configuration. Components needed to complete your job are simple… Vertical Supports (patented) RF’s vertical supports independently support cable tray without compromising raised access floor weight limitations or warranties. Vertical supports are offered in a side variety of heights. Part number: FTRF 2” Vertical Support - 2” Vertical Support FTRF 4” Vertical Support - 4” Vertical Support FTRF 6” Vertical Support - 6” Vertical Support FTRF 10” Vertical Support - 10” Vertical Support FTRF 12” Vertical Support - 12” Vertical Support FTRF 18” Vertical Support - 18” Vertical Support FTRF 20” Vertical Support - 20” Vertical Support (special sizes also available) Installs independently of Raised Floor System. Horizontal Support Bars Horizontal Supports have simple lock-in design to fit tray widths. Snap into vertical supports - then install tray - no fastening needed. Part number: FTRF 6” Horizontal Support - 6” Horizontal Support FTRF 12” Horizontal Support - 12” Horizontal Support FTRF 24” Horizontal Support - 24” Horizontal Support www.flextray.com 21 Trays come in 6”, 12” and 24” widths, in depths of 2”, 4” and 6” and lengths of 2’ and 4’ to fit through floor areas easily. Part number: FTRF 2X6X2 Tray Section 2 inch deep, 6 inch wide, 2 feet long FTRF 2X6X4 Tray Section 2 inch deep, 6 inch wide, 4 feet long FTRF 4X6X2 Tray Section 4 inch deep, 6 inch wide, 2 feet long FTRF 4X6X4 Tray Section 4 inch deep, 6 inch wide, 4 feet long FTRF 6X6X2 Tray Section 6 inch deep, 6 inch wide, 2 feet long FTRF 6X6X4 Tray Section 6 inch deep, 6 inch wide, 4 feet long FTRF 2X12X2 Tray Section 2 inch deep, 12 inch wide, 2 feet long FTRF 2X12X4 Tray Section 2 inch deep, 12 inch wide, 4 feet long FTRF 4X12X2 Tray Section 4 inch deep, 12 inch wide, 2 feet long FTRF 4X12X4 Tray Section 4 inch deep, 12 inch wide, 4 feet long FTRF 6X12X2 Tray Section 6 inch deep, 12 inch wide, 2 feet long FTRF 6X12X4 Tray Section 6 inch deep, 12 inch wide, 4 feet long FTRF 2X24X2 Tray Section 2 inch deep, 24 inch wide, 2 feet long FTRF 2X24X4 Tray Section 2 inch deep, 24 inch wide, 4 feet long FTRF 4X24X2 Tray Section 4 inch deep, 24 inch wide, 2 feet long FTRF 4X24X4 Tray Section 4 inch deep, 24 inch wide, 4 feet long FTRF 6X24X2 Tray Section 6 inch deep, 24 inch wide, 2 feet long FTRF 6X24X4 Tray Section 6 inch deep, 24 inch wide, 4 feet long Horizontal Fitting Flat Multi-Level Bracket This tray allows easy transition through T’s, elbows and crosses in your pathway. Use brackets to achieve multi-level pathways. p/n # FTRF 0x24x2 FTRF12CBRKT FTRF6BRKT FTRFLBRKT Ground Clip Vertical Clip UL approved connector. Use for additional hold down to Horizontal Supports and C Brkts for Multi-tier runs. Locks vertical support around stanchion. p/n # FTRF GROUND CLIP Union Made in the USA p/n # VERTICAL CLIP Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com RF raised floor system Trays 22 RF raised floor system RF accessories Cable Roller Flextray’s new Cable Roller maintains recommended cable radius in bends and turns. p/n# CABLE ROLLER label clip Label Clips enable wiring identification. p/n# LABEL CLIP (10/BX) Use as horizontal radius protection. www.flextray.com 23 cutting tools CleanShear ® Cut, Bend, Install…..Flextray can be formed into any pathway configuration by simply cutting and bending straight sections. Cleanshear is the only tool that eliminates sharp edges that could damage you or your cable installation. BAD Correct cut made with a CLEANSHEAR Cutter. patented Incorrect cut made with standard bolt cutter. Offset bolt cutters leave sharp edges. p/n# CLEANSHEAR How To Cut Flextray STEP 1 With tray facing up, position bolt cutter in the middle of a section. STEP 2 Slide bolt cutter to the right flush against the vertical wire at a 45˚ angle. STEP 3 Cut wire. STEP 4 Turn tray up, with open side facing you. Repeat steps 1 and 2. STEP 5 Face tray, open side down, and repeat steps 1 and 2 until all wires are cut on this side. STEP 6 Approach tray from opposite side and repeat steps 1-5 to cut wires on other side. CleanShear ® Bender – With Bending Attachment Cleanshear can be purchased with our exclusive bending attachment. It makes bending larger sized of tray easy. patented p/n# CLEANSHEAR BEND Union Made in the USA How To Bend Flextray STEP 1 Position bending tool between sections on the side wires with handles apart. STEP 2 Push handles together to bring tray together. Secure with hardware. Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com cutting tools GOOD 24 cutting tools AirShear Flextray offers the fastest cutting tool available. The patented Cleanshear cutting heads along cutting tools with effort free cutting make Flextray the fastest- safest pathway option to install. NEW! patented p/n#AIRSHEAR • TIME SAVINGS WITH AIRSHEAR 56.8% Cutting Method Tray Size CLEANSHEAR FT2 X 24 AIRSHEAR FT2 X 24 Configuration Time 1 minute 58 seconds 58 seconds Airshear operatate neumatically. 90 lbs PSI is required. 1/4” fitting. Cutting with Airshear makes installation fast www.flextray.com 25 creating fittings Making Horizontal Bends FLEXTRAY can be cut and formed on-site into nearly any configuration by cutting the bottom and side wires of the straight illustrate just a few suggested methods for creating bends. Please refer to your cable manufacturer’s suggested bend radius when forming FLEXTRAY. STEP 1 Position bending tool between sections on the side wires with handles apart. To create bends, simply remove sections of FLEXTRAY. For long radius bends, remove every other section. For short radius bends, remove one section and both side rails. STEP 2 Push handles together to bring tray together. Secure with hardware. Bends can be connected using FLEXMATE Connectors or Splice Washers, nuts and bolts. Union Made in the USA Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com creating fittings sections. After removing the cut wires, a radius can be bent and fastened with appropriate hardware. The following pages 26 creating fittings creating fittings Creating Horizontal Radius Bends 1 Connector Using the CLEANSHEAR Cutter, cut out sections. Using the CLEANSHEAR Bender pull sections together. FLEXMATE Connectors make it easy. Cut out one center section of 4" tray and one side rail both directions. Simply bend and attach with Top and Bottom Washers, nuts and bolts. Cut out two sections of larger sizes of FLEXTRAY and three side rail sections, both directions. Simply bend and attach with Top and Bottom Washers, nuts and bolts. 1 Bolt BOTTOM WASHER TOP WASHER 1 Nut 1 Bolt 2 SUPPORT WASHERS 1 Nut www.flextray.com 27 Creating Two-Piece Radius Bends This tight radius creating fittings style bend is accomplished by cutting FLEXTRAY and assembling using hardware shown. Union Made in the USA Remove two side rail sections. Overlap pieces and attach with two Washer Splice Kits. Smaller sizes may require only one set. Remove side rail sections. For larger sizes, use two Support Washers. Remove two side rail sections. Overlap pieces and attach with four FLEXMATE Connectors. Smaller sizes may require only two. Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com 28 creating fittings Making Tees creating fittings The flexibility of FLEXTRAY enables tees and intersections to be placed anywhere along the run at any time. Simply cut, bend and connect. Cut out side rail of main run according to width of the intersecting tee. Remove sections on both sides of the intersecting run. Bend the side rails out of both runs and connect to intersecting run with Splice Washers, nuts and bolts. Alternate wide radius 2" to 8". p/n# 90 DEGREE BAR Short radius 4" to 12" tee attached with 90 Degree Splice Bar. Wide radius 12" to 20" tee. www.flextray.com 29 Making Crosses Wide radius 12" to 20" tee. Reducing Sizes of Trays Reducing 12" to 8". Use 3 sets of Top and Bottom Washers, nuts and bolts to splice. Creating “Y” Fittings Attach pieces with Splice Washers, nuts and bolts. Remove side wires from main tray (1). Remove bottom wires at angles on attachment tray (2). Union Made in the USA Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com creating fittings Short radius 4" to 12" cross attached with 90 Degree Splice Bar. 30 creating fittings Making Vertical Fittings creating fittings Avoid any obstacles. It is easy with FLEXTRAY. Simply cut the side wires and bend. Simply cut side wires and bend. Alternate cuts allow a variety of vertical drops and rises. Whatever the obstacle. www.flextray.com 31 design/technical tools design/technical tools Tools Available for Architects, Consultants and Engineers Flextray offers information that will help you plan and design pathway applications. Our easy to use software and Technical Binder contain all the information you’ll need to complete your design. Call us at 1-888-353-9879 or email flextray@gsmetals.com to select your free tools today. Flextray offers answers to pathway questions. Ask for our Technical Updates today. We’ll keep you informed. www.flextray.com NEW! Our Website offers quick reference to all your Flextray questions. Use our product configurator to choose the materials you’ll need. Load/Fill rates and CSI specification are ready when you need them. Union Made in the USA Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com 32 design/technical tools design/technical tools CSI Specification Form Use this form to create the pathway specification you need. You can create your specification from our Selector Software CD or go to our website www.flextray.com. Pick the options you want to use in your specification. MANUFACTURER PRODUCT NAME ❑ FLEXTRAY® Cable Management System ❑ FLEXTRAY Cable Managment System, or approved equal. ❑ Approved Flexible site configurable wire mesh basket tray. Approved manufacturers are: ❑ Approved flexible site configurable wire mesh basket tray, 5mm minimum wire gauge MANUFACTURER ❑ GS Metals Corp. 3764 Longspur Road Pinckneyville, IL 62274, Phone: (888) 353-9879, Fax: (618) 357-8486, Website: www.FLEXTRAY.com, Email: flextray@gsmetals.com ❑ Approved Supplier ❑ Manufacturer must have US production facilities; tray must be produced and finished in United States with full domestic content. ❑ Product must be manufactured in unionized production facility by union workers. ❑ Manufacturer must have a demonstrated history of production and distribution of product offering for a minimum period of 3 years in the US. ❑ Tray specified shall be UL classified and listed. ❑ Tray specified shall have T-weld on top rail (all sizes of tray) in order to avoid sharp surfaces or protrusions on tray surface. ❑ Company shall be ISO 9001 Certified. CABLE MANAGEMENT SYSTEM PRODUCT DESCRIPTION FLEXTRAY is a welded wire mesh cable management system. The open mesh permits easy access to the tray and provides continuous ventilation of cables installed in the tray. A continuous ground conductor fixing system can be accomplished by the use of approved splices and bonding jumpers. GS Metals 'Flextray' continuous rigid welded steel wire mesh cable management system. 1. Continuous safety edge wire welded to top of tray. 2. Wire mesh welded at all intersections. UL CLASSIFICATION Straight sections 1.5x12, 2x6,2x8,2x12,2x16,2x18,2x20,2x24,4x4,4x8,4x12,4x16, 4x18,4x20 and 4x24 UL Classified. COMPOSITION & MATERIALS FLEXTRAY is produced from high mechanical strength steel wire, which is first welded into a net, then formed into channels to carry the cables. Covers and inserts are made from pregalvanized steel are available to protect cables. They are easily installed and can be easily lifted for maintenance activities. Splicing options in five styles made of electro galvanized steel effectively connects trays end to end. Material Carbon steel wire, ASTM A 510, Grade 1008. Wire welded bent and surface treated after manufacturer. Stainless steel wire AISI 316L, 2B, finished cold drawn wire. APPROVED TRAY ❑ FT1.5X4X10 ❑ FT2X2X10 ❑ FT2X12X10 ❑ FT2X24X10 ❑ FT2X34X10 ❑ FT4X16X10 ❑ FT4X26X10 ❑ FT6X16X10 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FT1.5X6X10 FT2X4X10 FT2X16X10 FT2X26X10 FT4X4X10 FT4X18X10 FT4X30X10 FT6X20X10 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FT1.5X8X10 FT2X6X10 FT2X18X10 FT2X30X10 FT4X8X10 FT4X20X10 FT6X8X10 FT6X24X10 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FT1.5X12X10 FT2X8X10 FT2X20X10 FT2X32X10 FT4X12X10 FT4X24X10 FT6X12X10 FT6X26X10 TO DENOTE BLACK FINISH, ADD BLE TO THE PART NUMBER Standard sizes - Mesh size is 2" x 4" (50 x 100 mm). The standard tray length is 118" (3 m) supplied in four channel depths, 1 1/2", 2", 4" and 6" (38, 54, 105 and 159 mm). Thirteen widths offered include 2", 4", 6", 8", 12" 16", 18", 20", 24", 26", 30", 32" and 34". (50,100, 150, 200, 300, 400 450, 500, 600, 650, 759, 800 and 850 mm). Special size - Custom sizes are available on request. Wire Diameter - A minimum of 0.197" on all mesh sections. FINISHES Finish options include: ❑ Electroplated Zinc Galvanizing (Standard Stock Finish) - Electrodeposited zinc coating applied to an average thickness of 0.7 mils (18 microns) to 0.8 mils (20 microns). This surface treatment is suitable for most indoor applications and may be used outdoors in mild environments only. ❑ Hot Dip Galvanizing - Provided by immersing the product in a molten zinc bath, this coating is applied to an average thickness of 2.4 mils (60 microns) to 3.2 mils (80 microns). This treatment is most suitable for outdoor applications or situations where increased corrosion resistance is desired. ❑ Epoxy Powder Coat Paint - Powder painted surface treatment using ASA 61. This finish option provides an aesthetically pleasing durable coating ideal for use in office buildings and various other indoor applications. Powder Coat colors are available on special request. ❑ Stainless Steel - Corrosive resistant AISI 316L Stainless Steel with no additional surface treatment. This material option provides the most corrosion resistant option available. Stainless steel is used primarily in marine environments or food processing facilities. LIMITATIONS See page 13 for capacities of various FLEXTRAY widths at different spans, or consult the software in the FLEXTRAY CD. TECHNICAL DATA APPLICABLE STANDARDS American Iron and Steel Institute (AISI)/American Society for Testing and Materials (ASTM) ASTM A123 - Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products ASTM A510 - General Requirements for Wire Rods and Coarse Round Wire, Carbon Steel ASTM A569 - Steel, Carbon (0.15 Maximum, Percent), Hot-Rolled Sheet and Strip Commercial Quality www.flextray.com 33 ASTM A570 - Standard Specification for Steel, Sheet and Strip, Carbon, Hot- Rolled, Structural Quality ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloyed-Coated (Galvanized) by the Hot-Dip Process ASTM B633 - Electrodeposited Coatings of Zinc on Iron and Steel National Uniform Seismic Installation Guide (NUSIG) AVAILABILITY Available nationwide from manufacturer's authorized representatives. APPROVALS FLEXTRAY meets applicable Underwriters Laboratories standards and requirements. Contact GS Metals for detailed UL classification information. WARRANTY Limited 3 year. Lifetime on materials and workmanship if Installed by a FLEXTRAY Certified Contractor. EXAMINATION MAINTENANCE None required. INSTALLATION METHODS FLEXTRAY can be fashioned on the job site by simply cutting the steel wires. The exclusive use of CleanShear cutters, NOT standard bolt cutters with an offset cutting blade jaw, is recommended to ensure a safe and finished edge entraining of a protective coat over cuts and creation of a galvanic couple to protect them. Install and support cable management system in accordance with span load criteria of L/240. PRECAUTIONS For Carbon Steel FLEXTRAY to be used as an equipment ground conductor, certain splicing methods must be used. Contact GS Metals for more information. Install cable management system using hardware, splice connectors, support components and accessories furnished by manufacturer. TECHNICAL SERVICES A free video/CD is available. Layout drawings and details in AutoCAD are provided upon request. Flextray offers its Configurator and FlexDraw software for determining requirements for Flextray. GS Metals Flextray representatives will assist with technical questions, provide assistance in determining bill of materials, and in installation management and training. SPEC-DATA® and MANU-SPEC® are registered trademarks of The Construction Specifications Institute. The ten-part SPEC-DATA format conforms to the editorial style of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. Filing Systems Architects' First Source for Products MANU-SPEC® Sweet's Catalog Files Additional product information is available from the manufacturer. product index 12 C Brkt . . . . . . . . . . . . . . . . . 9 12 CTR HGR . . . . . . . . . . . . . . . 8 12 L Brkt . . . . . . . . . . . . . . . . 10 12 Shelf Brkt . . . . . . . . . . . . . 10 16 CTR HGR . . . . . . . . . . . . . . . 8 16 L Brkt . . . . . . . . . . . . . . . . 10 16 Shelf Brkt . . . . . . . . . . . . . 10 18 CTR HGR . . . . . . . . . . . . . . . 8 18 Shelf Brkt . . . . . . . . . . . . . 10 20 CTR HGR . . . . . . . . . . . . . . . 8 20 L Brkt . . . . . . . . . . . . . . . . 10 20 Shelf Brkt . . . . . . . . . . . . . 10 24 CTR HGR . . . . . . . . . . . . . . . 8 24 L Brkt . . . . . . . . . . . . . . . . 10 24 Shelf Brkt . . . . . . . . . . . . . 10 4 C Brkt. . . . . . . . . . . . . . . . . . 9 4 CTR HGR . . . . . . . . . . . . . . . . 8 4 L Brkt . . . . . . . . . . . . . . . . . 10 4 Shelf Brkt . . . . . . . . . . . . . . 10 6 CTR HGR . . . . . . . . . . . . . . . . 8 8 C Brkt. . . . . . . . . . . . . . . . . . 9 8 CTR HGR . . . . . . . . . . . . . . . . 8 8 L Brkt . . . . . . . . . . . . . . . . . 10 8 Shelf Brkt . . . . . . . . . . . . . . 10 FT38075STB . . . . . . . . . . . . . . 16 FT38075WDB . . . . . . . . . . . . . 16 FT3810STB. . . . . . . . . . . . . . . 16 FT38125STB . . . . . . . . . . . . . . 16 FT38125STS . . . . . . . . . . . . . . 16 FT3820CTB. . . . . . . . . . . . . . . 16 Union Made in the USA FT3820STC . . . . . . . . . . . . . . . 16 FT3820WDB . . . . . . . . . . . . . . 16 FT3820WDS . . . . . . . . . . . . . . 16 FT3830WDB . . . . . . . . . . . . . . 16 FTBTM -btm mount nut drive . . 16 FTPOLE - extension Pole . . . . . 16 FTSIDE- side mount nut driver . 16 Pedestal Clamp . . . . . . . . . . . . 12 Pedestal Clamp kit . . . . . . . . . 12 12 in Cover . . . . . . . . . . . . . . 14 16 in Cover . . . . . . . . . . . . . . 14 18 in Cover . . . . . . . . . . . . . . 14 2 in Cover . . . . . . . . . . . . . . . 14 2 in Ctr Supt. . . . . . . . . . . . . . . 9 2 in Divider . . . . . . . . . . . . . . 14 20 in Cover . . . . . . . . . . . . . . 14 24 in Cover . . . . . . . . . . . . . . 14 4 in Cover . . . . . . . . . . . . . . . 14 4 in Divider . . . . . . . . . . . . . . 14 4 in Drop-Out . . . . . . . . . . . . . 13 6 in Cover . . . . . . . . . . . . . . . 14 6 in Drop-Out . . . . . . . . . . . . . 13 8 in Cover . . . . . . . . . . . . . . . 14 Airshear. . . . . . . . . . . . . . . . . 24 Attachment Clip . . . . . . . . . . . 11 Beam Clamps . . . . . . . . . . . . . 17 Btm Washer . . . . . . . . . . . . . . . 6 C Brackets . . . . . . . . . . . . . . . . 9 Cable Roller . . . . . . . . . . . . . . 22 Ceiling and Plenum Spaces. . . . . 2 Ceiling Rod Anchors. . . . . . . . . 16 Center Hangers. . . . . . . . . . . . . 8 Cleanshear . . . . . . . . . . . . . . . 23 Cleanshear Bend. . . . . . . . . . . 23 Coil Splice . . . . . . . . . . . . . . . . 7 Coil Spring Splice . . . . . . . . . . . 7 Conduit Clamps. . . . . . . . . . . . 15 Coupling Nuts . . . . . . . . . . . . . 17 Covers . . . . . . . . . . . . . . . . . . 14 Creating Fittings- Vertical . . . . . 30 Creating Fittings-"Y" . . . . . . . . 29 Creating fittings-Crosses. . . . . . 29 Creating Fittings-Horizontal . . . 25 Creating FittingsReducing sizes . . . . . . . . . . . 29 Creating fittings-Tees . . . . . . . . 28 Creating Fittingstwo piece horizontal. . . . . . . 27 Ctr Hung Supt. . . . . . . . . . . . . . 8 Design Tools . . . . . . . . . . . . . . 31 Dividers . . . . . . . . . . . . . . . . . 14 Drop-Outs . . . . . . . . . . . . . . . 13 Fill Rates . . . . . . . . . . . . . . . . . 5 Flat Washers. . . . . . . . . . . . . . 17 Flexmate System . . . . . . . . . . . 6 Flexmate Tool. . . . . . . . . . . . . . 6 Flexmate2 . . . . . . . . . . . . . . . . 6 FlexPack . . . . . . . . . . . . . . . . 18 Flextray Convenience Kits . . . . 18 Floor Pan 4 . . . . . . . . . . . . . . 12 Floor Pan 6 . . . . . . . . . . . . . . 12 FT1032SW . . . . . . . . . . . . . . . 17 FT1034SW . . . . . . . . . . . . . . . 17 FT1035SW . . . . . . . . . . . . . . . 17 FT1315SH . . . . . . . . . . . . . . . 17 FT1315SL. . . . . . . . . . . . . . . . 17 FT1842 . . . . . . . . . . . . . . . . . 17 FT1843 . . . . . . . . . . . . . . . . . 17 FT1844 . . . . . . . . . . . . . . . . . 17 FT1845 . . . . . . . . . . . . . . . . . 17 FT1859 . . . . . . . . . . . . . . . . . 17 FT1860 . . . . . . . . . . . . . . . . . 17 FT1861 . . . . . . . . . . . . . . . . . 17 FT1874 . . . . . . . . . . . . . . . . . 17 FT1876 . . . . . . . . . . . . . . . . . 17 FT1877 . . . . . . . . . . . . . . . . . 17 FT1881 . . . . . . . . . . . . . . . . . 17 FT1883 . . . . . . . . . . . . . . . . . 17 FT1884 . . . . . . . . . . . . . . . . . 17 FT1905 . . . . . . . . . . . . . . . . . 17 FT1906 . . . . . . . . . . . . . . . . . 17 FT1907 . . . . . . . . . . . . . . . . . 17 FT1908 . . . . . . . . . . . . . . . . . 17 FT1909 . . . . . . . . . . . . . . . . . 17 FT1910 . . . . . . . . . . . . . . . . . 17 FT1911 . . . . . . . . . . . . . . . . . 17 FT1912 . . . . . . . . . . . . . . . . . 17 FT1913 . . . . . . . . . . . . . . . . . 17 FT2003 . . . . . . . . . . . . . . . . . 17 FT2004 . . . . . . . . . . . . . . . . . 17 FT2005 . . . . . . . . . . . . . . . . . 17 FT5812SH . . . . . . . . . . . . . . . 17 FT5812SL. . . . . . . . . . . . . . . . 17 FT6030 -UBOLT CLAMP . . . . . . 17 FT6053 . . . . . . . . . . . . . . . . . 17 FT6054 . . . . . . . . . . . . . . . . . 17 FT6500 . . . . . . . . . . . . . . . . . 17 FT6502 . . . . . . . . . . . . . . . . . 17 FT6503 . . . . . . . . . . . . . . . . . 17 FTEMTDO075 . . . . . . . . . . . . . 15 FTEMTDO100 . . . . . . . . . . . . . 15 FTEMTDO125 . . . . . . . . . . . . . 15 FTEMTDO50 . . . . . . . . . . . . . . 15 Fthdwe 1/4 . . . . . . . . . . . . . . . 6 Ground Bolt . . . . . . . . . . . . . . 15 Ground Supt GL . . . . . . . . . . . 15 Hex Nuts:. . . . . . . . . . . . . . . . 17 insert 12x118 . . . . . . . . . . . . 14 insert 16x118 . . . . . . . . . . . . 14 insert 18x118 . . . . . . . . . . . . 14 insert 20x118 . . . . . . . . . . . . 14 insert 24x118 . . . . . . . . . . . . 14 insert 2x118 . . . . . . . . . . . . . 14 insert 4x118 . . . . . . . . . . . . . 14 insert 6x118 . . . . . . . . . . . . . 14 insert 8x118 . . . . . . . . . . . . . 14 L Brackets . . . . . . . . . . . . . . . 10 Label Clip. . . . . . . . . . . . . . . . 22 Load Tables . . . . . . . . . . . . . . . 5 Lock Washers . . . . . . . . . . . . . 17 Metal Framing . . . . . . . . . . . . 17 RF Components. . . . . . . . . . . . 20 RF System . . . . . . . . . . . . . . . 19 Rack Clamp . . . . . . . . . . . . . . 13 RackPack . . . . . . . . . . . . . . . . 18 Raised Access Floors . . . . . . . . . 3 Shelf Brackets. . . . . . . . . . . . . 10 Solid Bottom Inserts . . . . . . . . 14 Specification . . . . . . . . . . . . . . 32 Splice Bar. . . . . . . . . . . . . . . . . 7 Splice Methods . . . . . . . . . . . . . 6 Spring Nuts . . . . . . . . . . . . . . 17 Spring Splice . . . . . . . . . . . . . . 6 Square Washers . . . . . . . . . . . 17 Straight Sections . . . . . . . . . . . . 4 Support Methods. . . . . . . . . . . . 8 Supt Washer . . . . . . . . . . . . . . 11 Telecommunication Closets . . . . . 3 Threaded Rod . . . . . . . . . . . . . 17 Toolless Clip . . . . . . . . . . . . . . 13 Top Washer . . . . . . . . . . . . . . . 6 Trapeze Supt . . . . . . . . . . . . . . 8 UL Classified Sizes. . . . . . . . . . . 5 Wall Support. . . . . . . . . . . . . . 11 Wall Supports . . . . . . . . . . . . . 10 Washer Splice Kit . . . . . . . . . . . 6 Where to Use Flextray. . . . . . . . 2 Z Bracket . . . . . . . . . . . . . . . . 10 Need Help? Call Toll Free 1-888-353-9879 or email flextray@gsmetals.com product index Inspect areas to receive cable management system. Notify the Engineer of conditions that would adversely affect the installation or subsequent utilization of the system. DO not proceed with the installation until the unsatisfactory conditions are corrected. COST Product is priced per unit and may depend on quantities ordered. Many parts come in bags of 50. Installation cost may be affected by substrate fastening requirements. Local distributor will quote actual materials price. Refer to FLEXTRAY pricing guide for budgetary pricing. 3764 Longspur Road • Pinckneyville, IL 62274 618-357-5353 • 888-353-9879 • 618-357-3605 fax www.flextray.com 705-05