Reznor V3-UDSA Gas Fired Unit Heater
Transcription
Reznor V3-UDSA Gas Fired Unit Heater
UDSA & UDSBD model Gas-fired unit heaters for indoor installation Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new heat exchanger and burner. V3 is compact, lightweight and delivers the highest possible standards of energy efficiency and performance. Within the V3 range there are two distinct types of heaters; UDSA - models fitted with an axial fan. With a choice of 24 different units and a range of heat output ratings from 8 to 100 kW, these models are available with both horizontal and vertical down flow air discharge. UDSBD - models fitted with centrifugal blower in horizontal or vertical orientation. Sixteen sizes of heaters with heat outputs ranging from 15 to 64 kW. Both UDSA and UDSBD heaters are easy to install and they are suitable for a wide range of commercial and industrial applications such as retail premises, sports and leisure halls and warehouses to mention but a few. UDSA TECHNICAL DATA 008 Model 011 015 020 Gas categories 025 030 035 II 2H3+UK B22, C12, C32, C42, C52, C62, C82 Comb. air and venting; Type B & C Installations 1 Heat input (Hs) kW 8,8 13,2 17,6 22,0 30,8 35,2 42,2 Heat input (Hi) kW 7,9 11,9 15,9 19,8 27,8 31,7 38,0 Heat output kW 7,3 11,0 14,6 18,2 25,5 29,2 34,9 Thermal efficiency (Hi) % 92 92 92 92 92 92 92 natural gas G20 natural gas G25 m³/h 0,84 1,26 1,68 2,10 2,94 3,36 4,02 m³/h 0,98 1,46 1,95 2,44 3,42 3,90 4,68 propane G31 kg/h 0,62 0,93 1,24 1,55 2,16 2,47 2,96 Gas consumption rate Rc 1/2 Gas connection size (not Ø supply line size) K 32 32 32 32 32 32 29 Airflow (15°) m³/h 680 1020 1360 1700 2385 2725 3510 Motor speed Vent & combustion air connection collars rpm Ømm 1425 1425 1425 1425 950 950 950 80 80 80 80 100 100 100 Recommended maximum hor. mounting height 2 m m 2,5 2,5 3,0 3,0 3,5 3,5 3,5 8 10 13 16 20 22 25 4 dB(A) 47 46 47 48 50 51 55 Sound pressure level 5 dB(A) 40 39 40 41 43 44 48 Temperature rise T (±1) Horizontal air throw 3 Sound pressure level 230/240V 1N ~ 50Hz Electrical service (protection class IP 20) Maximum total electrical rating W Weight (net) kg 121 30 33 126 38 273 40 56 60 333 88 Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz Energy saving Easy installation and maintenance 4-way heat exchanger achieves over 92% ther- Up to 25% lighter than similar models and mal efficiency. easy to install. Reduced NOx emissions contribute to protect the Balanced flue wall terminal provides both flue environment. outlet and combustion air inlet, thereby reducing An improved airflow and a new louvre design installation time. give longer air throws and significantly All connections (gas and electricity) are reduce stratification within the accessible at one side of the heater. building. Consequently, the units are particularly suitable for well insulated Extended operational life buildings. If necessary, destratification fans can be installed. The titanium stabilised aluminised steel heat The aerodynamic heat exchanger profile enables exchanger is particularly strong and durable the UDSA model to increase the airflow up to providing additional temperature resistance. 40% with a 30% reduction of electrical Its weld free construction ensures long life. consumption. Patented self-aligning burner with single orifice eliminates possible flame impingement and premature heat exchanger failure. Maintenance is very simple thanks to the use of a single gas injector for all models. 043 050 055 064 073 085 100 II 2H3+UK Application versatility Both horizontal and vertical downflow units are B22, C12, C32, C42, C52, C62, C82 50,8 58,6 66,0 77,7 88,0 102,7 117,3 45,8 52,8 59,5 70,0 79,3 92,5 105,7 42,1 48,6 54,7 64,4 73,0 85,1 97,0 92 92 92 92 92 92 92 4,85 5,59 6,30 7,41 8,39 9,79 11,18 5,64 6,50 7,32 8,62 9,76 11,38 13,00 3,57 4,12 4,64 5,46 6,18 7,21 8,24 28 28 28 28 28 28 28 4535 5180 5830 6810 7770 9065 10360 950 950 950 950 950 950 950 available. Fourteen different heat outputs from 8 to 100 kW. The smallest unit is only 310mm high - making it ideal for mounting in confined spaces. Rc 3/4 100 100 130 130 130 130 130 3,5 3,5 3,5 4,0 4,0 4,0 4,0 28 30 30 33 35 36 39 54 55 56 56 58 59 59 47 48 49 49 51 52 52 490 490 490 678 848 848 848 99 99 112 118 143 158 168 Units may be suspended or base mounted on a suitable support (fixed or pivoting). 230/240V 1N ~ 50Hz Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz UDSA HORIZONTAL MODEL MODEL UDSA DIMENSIONS (mm ± 2) Size A B C D E F G H J K L M N P Q R 008, 011 307 700 267 404 696 546 131 191 129 67 85 413 16 98 350 120 015 383 700 343 404 723 546 200 191 139 122 86 413 16 98 350 120 020 383 700 343 404 723 546 200 191 139 122 86 413 16 98 350 120 025 586 700 546 404 771 546 368 191 222 122 121 413 16 98 350 140 030 586 700 546 404 771 546 368 191 222 122 121 413 16 98 350 140 035, 043, 050 510 971 456 601 1129 897 371 195 126 166 121 623 33 149 600 140 055, 064 663 971 609 601 1138 897 354 207 150 166 204 623 33 149 600 225 073, 085, 100 865 1040 812 651 1138 897 562 213 299 186 204 673 33 149 600 225 2. Flue connection 3. Gas connection 4. Electrical connections 5. Service panel Q E B F A C M D P N 1. Combustion air inlet 5 3 SIDE VIEW FRONT VIEW 1 2 TOP VIEW J G L R 4 K H REAR VIEW REAR VIEW (all models except for 035, 043, 050) (models 035, 043, 050) BALANCED FLUE WALL AND ROOF TERMINAL Type C12 Type C12b Type C52 Type C32 Type B22 Type B22b C- type: : the allowed length between the unit heater and the flue terminal amounts to 9m, a 90° bend offering an equivalent resistance of 1.5m and a 45° bend -0.75m Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz UDSA VERTICAL MODEL To ensure that heat losses through the roof are kept to a minimum and to avoid the occurrence of stratification, it is possible to suspend the UDSA unit in a vertical orientation. This way of suspension allows the unit to dually operate as a heater and as destratification unit. The option ‘vertical orientation’ (option number 205.8) can only be applied on the UDSA models 015, 025, 035, 043, 050, 055, 064, 073, 085 & 100. All vertical UDSA models are fitted with a 4way outlet grill (no louvres) and can be functioning as a destratification unit by placing a destratification thermostat (option 904) on the unit. The unit now helps ventilating and recirculating the warm air towards the floor, resulting in energy savings and climate comfort. Diffuser grill louvre setting H Floor pattern Maximum mounting height from floor H (m) (1) Air louvres Air louvres Air louvres Model Neutral 30° 45° 015 5,0 4,5 4,0 025 6,0 5,0 4,5 035 7,0 6,0 5,5 043 9,0 7,5 7,0 050 10,0 8,5 7,5 055 9,0 7,5 7,0 064 10,5 8,5 8,0 073 10,0 8,0 7,5 085 11,0 9,0 8,5 100 12,0 10,0 9,0 (1) max. mounting heights are defined at a uniform room temperature of 15°C and a temperature rise at nominal heat output Q MOUNTING DATA M P N MODEL UDSA DIMENSIONS (mm ± 2) Model E F M N P Q 015 864 686 413 16 67 250 025 918 686 413 16 68 450 035, 043, 050 1270 1037 623 35 55 400 1278 1037 623 35 82 500 073, 085, 100 1317 1057 673 35 183 500 055, 064 for other dimensions: see table indicated as horizontal UDSA model Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz UDSBD CENTRIFUGAL MODEL These indirect gas-fired unit heaters have separated combustion and an atmospheric burner. The units are equipped with a direct drive centrifugal blower and they can operate effectively at a resistance output of up to 150 Pa. Furthermore, there is a choice of three types of air distribution: plenum type, standard outlet grill (fitted with vertical louvres) and downturn nozzles. The unit is also available in vertical downflow orientation in sizes 015, 025, * outlet grill is optional 035, 043, 050, 055 and 064. Designed for recirculation and air distribution through ductwork UDSBD units are ideal for open doorway heating (to prevent heat escaping) or for providing temperature controlled space heating. UDSBD TECHNICAL DATA 015 Model 020 025 Gas categories 030 035 043 050 II 2H3+UK B22, C12, C32, C42, C52, C62, C82 Comb. air and venting; Type B & C Installations 1 Heat input (Hs) kW Heat input (Hi) kW 17,6 15,9 22,0 19,8 30,8 27,8 35,2 31,7 42,2 38 50,8 45,8 58,6 52,8 Heat output kW 14,6 18,2 25,5 29,2 34,9 42,1 48,6 Thermal efficiency (Hi) % 92 92 92 92 92 92 92 natural gas G20 natural gas G25 m³/h 1,68 2,10 2,94 3,36 4,02 4,85 5,59 m³/h 1,95 2,44 3,42 3,90 4,68 5,64 6,50 propane G31 kg/h 1,24 1,55 2,16 2,47 2,96 3,57 4,12 Rc 3/4 31 Gas consumption rate Gas connection size (not Ø supply line size) Temperature rise T (±1) 6 Airflow (15°) K m³/h 2150 Motor speed rpm Standard low, mid or high speed Recommended maximum hor. mounting height 2 20 Rc 1/2 23 27 25 25 2350 2750 3360 4080 3900 29 950 950 1430 1430 950 950 950 mid high low mid low low mid 4900 m m 3,5 4 4,5 4,5 5,5 5,5 6 Horizontal air throw 3 18 23 26 26 32 34 38 Sound pressure level 4 dB(A) 50 52 47 51 46 47 52 Sound pressure level 5 dB(A) 57 58 54 58 53 54 59 230/240V 1N ~ 50Hz 1662 1662 1700 1700 1700 131 131 Electrical service (protection class IP 20) Maximum total electrical rating W 496 496 Weight (net) kg 50 53 71 74 125 Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz MODEL UDSBD DIMENSIONS (mm ± 2) Size A B C D E 015, 020 383 460 A1 700 343 404 935 546 199,5 191 025, 030 586 590 700 546 404 1185 546 367,5 035, 043, 050 510 670 970 456 601 1610 897 371 055 663 685 970 609 601 1610 897 354 064 663 720 970 609 601 1610 897 354 1. Combustion air inlet 2. Flue connection F 3. Gas connection G H J K 139 122 N P Q 86 413 15,5 98 350 120 191 222 194 126 122 121 413 15,5 98 350 140 165 121 623 33 148,5 600 140 206 206 150 165 204 623 33 148,5 600 225 150 165 204 623 33 148,5 600 225 4. Electrical connections L M R 5. Service panel D FRONT VIEW REAR VIEW (models 015, 020, 025, 030, 055, 064) 055 064 66,0 59,5 77,7 70 54,7 64,4 92 92 6,30 7,41 7,32 8,62 4,64 5,46 30 32 5300 5390 950 950 mid high 6 6 38 38 50 53 57 60 1700 1700 148 153 SIDE VIEW TOP VIEW REAR VIEW (models 035, 043,050) 1) Gas appliance classifications for approved venting methods based on CEN report - CR1749:2001. 2) Height from floor to bottom surface of the heater. These are RECOMMENDATIONS ONLY. Positioning of unit heaters for proper performance is application dependent. Operation is affected by other air moving equipment in the space, obstructions to the airflow, draughts and/or close proximity doors or windows, etc. Care should be taken to avoid mounting the heaters above these recommendations, unless downturn nozzle options are used, as significant stratification may occur, resulting in poor floor coverage and higher energy losses trough the roof structure. 3) Isothermal conditions , 20 °C ambient air temperature , discharge louvres , zero deflection , v=0,5m/s. 4) dB(A) values at 5 meters from the unit with reference circumstances A=160m² and Q=2. 5) dB(A) values at 5 meters from the unit in free field. 6) Values mesured with an external static pressure of 150 Pa. Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz OPTIONS Unit heater accessories Flue outlet • Two stage burner control • Balanced flue wall and roof terminal • Modulating burner control - Aluminised steel plate • Propane model - Adjustable chimney for pitched roof. • Destratification thermostat • Heat exchanger SS 409 Mounting • Diffuser grill with horizontal louvres • Both fixed or pivoting wall brackets are available. • 30° and 60° discharge nozzle • Vertical louvres • Duct flange * Wall brackets for UDSA models 008-030 • Constant running fan * 30° or 60° discharge nozzle Control equipment Wall brackets for UDSA models 035-100 • Combined thermostat with burner ‘on’ indicator and reset-function. • One or two stage clock thermostat with burner ‘on’ indicator and reset. • Energymizor thermostat with time and temperature control for one stage, two stage and modulating REZNOR unit heaters. The microprocessor adjusts the heating period and the air temperature. Several thermostats can be Pivoting wall bracket for UDSA models connected together. - Room temperature sensor for space heating. - In-duct temperature sensor for warm air inlet system.* • Two stage duct thermostat. * * UDSBD models only Company Standards and Services: All Reznor products are tested and approved to CE standards. Reznor Europe nv is assessed to GASTEC EN ISO 9001: 2000 Quality Assurance. Reznor offers a service to its customers; including budget schemes, on site technical support and a comprehensive after-sales package. Reznor reserves the right to change specifications without prior notice. J&M Sabbestraat 130 B-8930 Menen Reznor Europe N.V. Belgium • www.ReznorOnline.com E-mail: reznor_europe@tnb.com Tel. +32(0) 56 52 95 11 Fax. +32 (0) 56 52 95 33 Wijzigingen voorbehouden e-mail: reznor_europe@tnb.com Cooke website: Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Web:Group www.cookeindustries.co.nz A T&B Company G A S T E C Email: sales@cookeindustries.co.nz www.reznor.be
Similar documents
Mall Map PDF
F15 A3 D35 K14 F13 F10 C41 K29 D22 A4 C1 D1 K17 K24 D39 F8 A17 D3 C20 K8 A32 A34 D31 D11 K14 F12
More information