thermobond - Eagle County
Transcription
thermobond - Eagle County
BUILDING EXTERIOR BUFF OZARK GREY OTHER PROJECT EAGLE COUNTY JOB NO. 1212-960 SITE NAME COOLEY MESA, CO SIZE 10'W. OD X 16'L. OD X 9'H. ID DRAWING TITLE DRAWING NUMBER DRAWING INDEX_______________________________ AGB9065 PAGE 1 OF 11 NOTES SHEET__________________________________ AGB9065 PAGE 2 OF 11 BILL OF MATERIALS____________________________ AGB9065 PAGE 3 OF 11 INTERIOR LAYOUTS____________________________ AGB9065 PAGE 4 OF 11 ELEVATION VIEWS_____________________________ AGB9065 PAGE 5 OF 11 ELECTRICAL PANEL____________________________ AGB9065 PAGE 6 OF 11 ALARM PANEL_________________________________ AGB9065 PAGE 7 OF 11 BUILDING CONSTRUCTION DETAILS_____________ AGB9065 PAGE 8 OF 11 BUILDING CONSTRUCTION DETAILS_____________ AGB9065 PAGE 9 OF 11 BUILDING CONSTRUCTION DETAILS_____________ AGB9065 PAGE 10 OF 11 BUILDING INTEGRATION DETAILS______________ AGB9065 PAGE 11 OF 11 BUILDING SKID ASSEMBLY_____________________ 15B1016 PAGE 1 OF 2 GROUNDING PLATE DETAIL_____________________ 15B1016 PAGE 2 OF 2 BUILDING FOUNDATION ASSEMBLY_____________ P15B1016 PAGE 1 OF 1 12/31/14 1 THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. THERMOBOND USAGE_________________ ________UNMANNED SHELTER CONSTRUCTION TYPE___ _______________________VB OCCUPANCY GROUP____ ________________________S-2 STORIES________________ ___________________________1 BASIC WIND SPEED_____ _________100 MPH 3 SEC GUST FLOOR LOAD___________ _______________________200 PSF ROOF LOAD____________ __________________________65 PSF FLOOR AREA___________ ___________________160 SQ.FT. BUILDING HEIGHT______ ______________________10'-10" SEISMIC DESIGN________ ______________________CAT D WIND EXPOSURE_______ ________________________CAT C BUILDINGS CODES: 2012 INTERNATIONAL BUILDING CODE (IBC) 2012 INTERNATIONAL MECHANICAL CODE (IMC) 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2011 NATIONAL ELECTRICAL CODE (NEC) NOTES: PFS LABEL TO BE LOCATED ON INSIDE COVER OF MAIN BREAKER PANEL. DATA PLATE TO BE LOCATED ON OUTSIDE COVER OF MAIN BREAKER PANEL. STATE OF CO INSIGNIA TO BE LOCATED ON OUTSIDE OF DOOR ABOVE PASSAGE. NONE 8/7/13 DJO 1212-960 DRAWING INDEX EAGLE COUNTY AGB9065 PAGE 1 OF 11 ITEMS SHIPPED LOOSE 1. HOLD DOWN PLATES, WASHERS, AND NUTS CONSTRUCTION NOTES 1. FLOOR TO HAVE 2X4 JOISTS ON 16" CENTERS 2. FLOOR TO HAVE R-11 FIBERGLASS INSULATION 3. WALLS TO HAVE 2X4 STUDS ON 16" CENTERS 4. WALLS TO HAVE R-11 FIBERGLASS INSULATION 5. ROOF TO HAVE 2X6 JOISTS ON 16" CENTERS 6. ROOF TO HAVE R-19 FIBERGLASS INSULATION 7. ROOF TO BE CDX PLYWOOD 8. PERIMETER SKID TO BE PAINTED WITH BROWN RUST PREVENTATIVE PAINT ELECTRICAL NOTES 1. ALL WIRING SHALL BE IN ACCORDANCE WITH THE 2011 NATIONAL ELECTRIC CODE. 2. ALL ELECTRICAL MATERIALS SHALL BE U.L. LISTED AND CLASSIFIED AS SUITABLE FOR THE PURPOSE SPECIFIED. 3. ALL WIRING SHALL BE SURFACE MOUNTED IN A RACEWAY OR EMT CONDUIT USING APPROVED CONNECTORS, COUPLINGS, AND CLAMPS, ALL CONDUIT SHALL BE ANCHORED IN PLACE AT APPROXIMATELY EVERY 4 FT. 4. ALL WIRING SHALL BE A SOLID CONDUCTOR, THHN OR THWN COPPER, NO SMALLER THAN A #12. 5. ALL WIRE RUNS SHALL BE CONTINUOUS. 6. LOW VOLTAGE WIRE MAY BE STRANDED. 7. ALL WIRING SHALL BE TESTED AND INSPECTED PRIOR TO SHIPMENT. 8. GREEN GROUND CONDUCTORS SHALL BE RUN TO ALL OF THE BUILDINGS A/C POWERED DEVICES. CONDUIT SHALL NOT BE USED AS THE SOLE SOURCE OF GROUND. 9. ALL ALARM DEVICES WIRING SHALL BE RUN IN ITS OWN CONDUIT TO THE ALARM CABINET. 10. ELECTRICAL CONDUIT COUPLERS WILL BE COMPRESSION TYPE FITTINGS. INTEGRATION NOTES 1. R-56 GROUNDING: HALO GROUND TO BE BARE #2 AWG. HALO WILL HAVE A 4" SPARK GAP INSTALLED UNLESS OTHERWISE SPECIFIED OPPOSITE THE ENTRANCE PORT. METALLIC PANELS LARGER IN SIZE THAN A 4"X4" OUTLET BOX, DOOR FRAMES & HVAC GRILLES WILL BE BONDED TO THE PERIMETER HALO GROUND WITH A GREEN #6 WIRE, C-TAP AND WITH A TWO HOLE LUG. LADDER RACK SECTIONS TO BE BONDED WITH #6 JUMPERS & BONDED TO MGB. LIGHTS WILL BE BONDED METALLIC CONDUIT THAT RUNS PARALLEL TO THE HALO CONDUCTOR SHALL BE BONDED AT THE POINTS WHERE IT ENTERS TO WITHIN (6") OF THE HALO CONDUCTOR & AT THE POINT WHERE IT TRANSITIONS AWAY FROM THE HALO CONDUCTOR. BONDING LUG POSITIONS WILL BE ON THE SKID FOR BONDING OF HVAC, HOODS AND ANYTHING FOR THE OUTSIDE. DOOR & ENTRANCE PORT WILL BE BONDED ON THE INSIDE OF THE SHELTER. LINEUP FEEDER OF #2 GREEN WILL BE RUN ALONG EACH CABLE LADDER LINEUP & BONDED TO THE MGB. LOCATIONS OF BONDED ITEMS ARE TO BE COMPRESSED TO ONE END OF THE SHELTER AS MUCH AS POSSIBLE TO KEEP IMPEDANCE BETWEEN OBJECTS AS LOW AS POSSIBLE. 2. CABLE LADDER TO BE MOUNTED AT 7'-2" A.F.F. REVISION LOG DATE 12/27/14 DRAFTER DJO REVISION MOVED WAVEGUIDE, DOOR, LIGHTS, SWITCHED TO B1447 AND PIERS THERMOBOND BUILDINGS THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. NONE 8/7/13 DJO 1212-960 NOTES SHEET EAGLE COUNTY AGB9065 PAGE 2 OF 11 THERMOBOND BUILDINGS THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. NONE 8/7/13 DJO 1212-960 BILL OF MATERIALS FOR 10'W. OD X 16'L. OD X 9'H. ID BLDG. EAGLE COUNTY AGB9065 PAGE 3 OF 11 15'-143" NOTES: 1. ALL CONDUIT SHOWN IS APPROXIMATE AND MAY NOT REFLECT ACTUAL RUNS IN BUILDING 7' 6" 4' 2' 2' 3 18 16 2 1 6 14 19 20 5 10 6' 21 9' POTENTIAL CUSTOMER RACK LAYOUT 4' 2'-6" 22 10 1'-6" 8 9'-134" 17 7 9 9 9 12 8 2'-6" 1'-6" 11 23 24 LIGHTS TO BE MOUNTED ON UNISTRUT TO ALLOW CONDUIT TO RUN UNDERNEATH 23 10 THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. 24 THERMOBOND BUILDINGS 1/4" = 1' 8/7/13 DJO 2' 1212-960 INTERIOR LAYOUT FOR 10'W. OD X 16'L. OD X 9'H. ID BLDG. EAGLE COUNTY AGB9065 PAGE 4 OF 11 METAL ROOF EDGE METAL ROOF EDGE AGGREGATE EXTERIOR PANEL AGGREGATE EXTERIOR PANEL 1" GROUNDING PENETRATION 3 1 13 8 15 METAL ROOF EDGE AGGREGATE EXTERIOR PANEL METAL ROOF EDGE AGGREGATE EXTERIOR PANEL 8 8 BARD BARD 8 4 THERMOBOND BUILDINGS THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. 1/4" = 1' 8/7/13 DJO 1212-960 EXTERIOR LAYOUT FOR 10'W. OD X 16'L. OD X 9'H. ID BLDG. EAGLE COUNTY AGB9065 PAGE 5 OF 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 39 38 41 42 UTILITY MAIN BREAKER W/ BONDING BUSHING MANUAL TRANSFER SWITCH MAIN PANEL 20 GENERATOR RECEPTACLE WIRING SCHEMATIC 40 THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. THERMOBOND BUILDINGS NONE 8/7/13 DJO 1212-960 LOAD CENTER EAGLE COUNTY AGB9065 PAGE 6 OF 11 ALARM BLOCK 1 2 DOOR #22 SOLID 3 4 SMOKE #22 SOLID 5 6 HIGH TEMP #22 SOLID 7 8 LOW TEMP #22 SOLID 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 NOTES: 1. PROVIDE A LABLE ON THE BLOCK COVER LISTING ALL ALARMS AND TERMINAL LOCATIONS. 2. ALL ALARMS WIRED IN NORMALLY OPEN POSITION UNLESS NOTED. 3. BRIDGE CLIPS TO BE INSTALLED ON ALL TERMINATED ALARMS. 38 39 40 41 42 43 THERMOBOND BUILDINGS 44 45 46 47 48 49 NONE 8/7/13 DJO ALARM PANEL 50 1212-960 EAGLE COUNTY AGB9065 PAGE 7 OF 11 3/4" CDX PLYWOOD NAILED TO 2 X 4 W/.131" X 3" NAIL 45 MIL REINFORCED TPO ROOFING MEMBRANE FULLY ADHERED WITH TPO BONDING ADHESIVE TO PLYWOOD WALLS ARE FASTENED IN CORNERS WITH 3/8" X 6" LAG BOLTS EVERY 24" O.C. AGGREGATE CORNER PIECE FASTENED W/#10 X 2 1/2" S.S. SCREWS 12" O.C. PAINTED ROOF EDGE NAILED TO PLYWOOD 2 X 4 TAPERED TO FORM ROOF PITCH, NAILED W/#12D & 60D NAILS 12" O.C. DOW STYROFOAM WETHERMATE PLUS HOUSE WRAP 2 X 6'S @ 16" O.C. R-19 FIBERGLASS INSULATION 2 X 4 TOP PLATE FASTENED TO TOP OF WALL WITH #12D COMMON NAIL EVERY 12" R-11 FIBERGLASS DOW STYROFOAM WETHERMATE PLUS HOUSE WRAP ROOF FASTENED TO WALL EVERY 24" WITH 3/8" X 6" LAG BOLTS COUNTERSUNK 1 1/2" 1/2" EXTERIOR RATED WALL SHEATHING PANEL W/.131" X 3" NAIL COVE MOLDING COVE MOLDING R-11 FIBERGLASS 1/2" EXTERIOR RATED WALL SHEATHING PANEL W/.131" X 3" NAIL INTERIOR WALL AND CEILING TO TO BE FINISHED WITH 3/4" PREFINISHED FRP/OSB BOARD #5 AGGREGATE PANEL SCREWED VERTICALLY 12" O.C. PERIMETER OVER STUDS AND 24" IN FIELD W/2" S.S. SCREWS AGGREGATE PANEL SCREWED VERTICALLY 12" O.C. PERIMETER OVER STUDS AND 24" IN FIELD W/2" S.S. SCREWS INTERIOR OF WALL TO BE FINISHED WITH 3/4" FRP/OSB BOARD 3 1/2" FIBERGLASS INSULATION INTERIOR OF WALL TO BE FINISHED WITH PREFINISHED FRP/OSB BOARD AGGREGATE PANEL SCREWED VERTICALLY 12" O.C. PERIMETER OVER STUDS AND 24" IN FIELD W/2" S.S. SCREWS DOW STYROFOAM WETHERMATE PLUS HOUSE WRAP 2" BASEBOARD NOTES: 1. ALL PLYWOOD SHALL BE NAILED EVERY 6" AROUND PERIMETER AND EVERY 12" IN FIELD. 2. HOUSE WRAP TO BE INSTALLED 1/8" BELOW SHEETING AND EXTEND TO TOP OF TOP PLATE. ALL SEAMS TO BE LAPPED 6" AND TAPED W/SEAM TAPE. 3. ALL SCREW HOLES THROUGH PANELS FILLED WITH POLYURETHANE CAULK PRIOR TO SCREW BEING INSTALLED. 4. ALL STRUCTURAL LUMBER SHALL BE SPF #1 OR #2. 5. ALL CDX, EXTERIOR SHEATHING & T&G GLUED TO STUDS WITH ENERBOND SF GLUE TO ALL STUDS BEFORE NAILING. 1/8" COMMERCIAL GRADE TILE 1/2" EXTERIOR RATED WALL SHEATHING PANEL W/.131" X 3" NAIL WALL FASTENED TO FLOOR EVERY 24" WITH 3/8" X 3" LAG BOLT 2 X 4'S @ 16" O.C. R-11 FIBERGLASS BOTTOM OF WALL SEALED WITH CONSTRUCTION ADHESIVE SEALANT 3/4" T & G STURD-I-FLOOR NAILED TO FLOOR FRAMING W/.131" X 3" NAIL THERMOBOND BOTTOM OF FLOOR IS 3/4" CDX PLYWOOD SEALING WITH AN ASPHALT UNDERCOATING AND A 18 X 16 X .011 WIRE MESH FOR RODENT PROTECTION BUILDINGS 3/8" X 3" LAG BOLT @ 12" O.C. 6" X #9 BEAM THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. NONE 8/7/13 DJO 1212-960 BUILDING CONSTRUCTION DETAILS EAGLE COUNTY AGB9065 PAGE 8 OF 11 3/4" T & G STURD-I-FLOOR NAILED TO FLOOR FRAMING WITH .131" X 3" NAILS 1/8" COMMERCIAL GRADE TILE 2 X 4'S @ 16" O.C. R-11 FIBERGLASS INSULATION BOTTOM OF FLOOR IS 3/4" CDX PLYWOOD SEALED WITH ASPHALT UNDERCOATING AND A 18 X 16 X .011 WIRE MESH FOR RODENT PROTECTION INTERIOR FRP/OSB BOARD FASTENED TO 2 X 4 W/#8D FINISH NAIL. 2 X 4'S @ 16" O.C. FLOOR PANEL INTERIOR TRIM STRIP FASTENED TO SEAM AGGREGATE PANEL SCREWED VERTICALLY 12" O.C. PERIMETER OVER STUDS AND 24" IN FIELD W/2" S.S. SCREWS R-11 FIBERGLASS INSULATION DOW STYROFOAM WETHERMATE 2" AGGREGATE TRIM STRIP 1/2" EXTERIOR RATED WALL PLUS HOUSE WRAP SHEATHING PANEL W/.131" X 3" NAIL 1/4" GAP BETWEEN AGGREGATE PANELS FILLED W/1/4" X 1/4" POLYURETHANE CAULK. THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. NOTES: 1. ALL PLYWOOD SHALL BE NAILED EVERY 6" AROUND PERIMETER AND EVERY 12" IN FIELD. 2. HOUSE WRAP TO BE INSTALLED 1/8" BELOW SHEETING AND EXTEND TO TOP OF TOP PLATE. ALL SEAMS TO BE LAPPED 6" AND TAPED W/SEAM TAPE. 3. ALL SCREW HOLES THROUGH PANELS FILLED WITH POLYURETHANE CAULK PRIOR TO SCREW BEING INSTALLED. 4. ALL STRUCTURAL LUMBER SHALL BE SPF #1 OR #2. 5. ALL CDX, EXTERIOR SHEATHING & T&G GLUED TO STUDS WITH ENERBOND SF GLUE TO ALL STUDS BEFORE NAILING. THERMOBOND BUILDINGS NONE 8/7/13 DJO 1212-960 BUILDING CONSTRUCTION DETAILS EAGLE COUNTY AGB9065 PAGE 9 OF 11 2 X 4 ON CENTER LINE OF ROOF AND FASTENED TO ROOF WITH #60D NAILS EVERY 12" O.C. 3/4" CDX PLYWOOD NAILED TO 2 X 4 W/.131" X 3" NAILS. 2 X 4 TAPERED TO FORM ROOF PITCH 2 X 6 ROOF JOIST SPACED 16" O.C. INTERIOR PREFINISH FRP/OSB TO BE FASTENED TO 2 X 4 W/#8D FINISH NAIL. 3/4" CDX PLYWOOD NAILED TO 2 X 4 W/.131" X 3" NAILS. 2 X 6 ROOF JOIST SPACED 16" O.C. NOTES: 1. ALL PLYWOOD SHALL BE NAILED EVERY 6" AROUND PERIMETER AND EVERY 12" IN FIELD. 2. HOUSE WRAP TO BE INSTALLED 1/8" BELOW SHEETING AND EXTEND TO TOP OF TOP PLATE. ALL SEAMS TO BE LAPPED 6" AND TAPED W/SEAM TAPE. 3. ALL SCREW HOLES THROUGH PANELS FILLED WITH POLYURETHANE CAULK PRIOR TO SCREW BEING INSTALLED. 4. ALL STRUCTURAL LUMBER SHALL BE SPF #1 OR #2. 5. ALL CDX, EXTERIOR SHEATHING & T&G GLUED TO STUDS WITH ENERBOND SF GLUE TO ALL STUDS BEFORE NAILING. DOUBLE 2 X 4 TOP PLATE. THERMOBOND BUILDINGS THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. NONE 8/7/13 DJO 1212-960 BUILDING CONSTRUCTION DETAILS EAGLE COUNTY AGB9065 PAGE 10 OF 11 #2 AWG BARE STRANDED COPPER WIRE CABLE LADDER SECTION BURNDY COMPRESSION CLAMP 2 HOLE LUG #6 STRANDED COPPER WIRE 8" RADIUS MIN. POINT BLUNT END TOWARDS GROUND BAR #6 AWG GREEN JACKETED STRANDED WIRE GROUND CLAMP CORNER CLAMP CONDUIT TYPICAL CONDUIT GROUNDING LADDER BONDING #2 AWG BARE STRANDED COPPER WIRE BURNDY COMPRESSION CLAMP CABLE LADDER SECTION #6 STRANDED COPPER WIRE SPLICE CLAMP POINT BLUNT END TOWARDS GROUND BAR #6 AWG GREEN JACKETED STRANDED WIRE PANDUIT STANDOFF 2 HOLE LUG SPLICE CLAMP METALLIC EQUIPMENT 2 HOLE LUG 2 HOLE LUG LADDER SPLICE WITH BONDING JUMPER EQUIPMENT & FRAME BONDING TO HALO GROUND GROUNDING: 1. USE NO-OX AT ALL GROUND TERMINATIONS. 2. PLACE HEAT SHRINK TUBING ON GROUND BAR PIGTAILS THAT CROSS WALL MOUNTED CONDUIT. 3. All STANDOFFS ARE SPACED 24" O.C. 4. ALL DOORS ARE TO BE GROUNDED TO THEIR FRAMES WITH WELDING WIRE. USE #2 GAUGE WELDING WIRE AND BURNDY TWO-HOLE LUGS. PLACE A 2" BAND OF GREENTAPE AT EACH END OF THE JUMPER. THERMOBOND BUILDINGS NONE 8/7/13 DJO 1212-960 BUILDING INTEGRATION DETAILS EAGLE COUNTY AGB9065 PAGE 11 OF 11 15'-10 1/4" 6" 2'-6" 2' 1 6" 4 4 DOOR 4 4 6" 4 4'-11 1/8" 6" 4 4' 4' 4' 3'-1014" 2 3 9'-10 1/4" 3 4'-11 1/8" 1 3 6" 2 1 4 1 4 6" 1 4 6" 1'-6" 12'-10 1/4" 1'-6" 3/8" = 1' SCALE TOP VIEW BUILDING ANCHOR BOLT 3 SKID BEAM 3/16" 3/16" TYP. 1 3/16" 3/16" HOLD DOWN PLATE THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. 4. 3. 2. 1. 9 6 2 5 A36 A500B A992 TOTAL BLACK STEEL WEIGHT 6" GROUND PLATE ANGLE, SUPPORT (2 X 2 X 1/4) PIPE SUPPORT (3" NOM. SCH 40) BEAM SUPPORT (W6 X 9#) GRADE 50 864.6# 95.7# 156.9# 612.0# TYP. 1 FOUNDATION NOTES: 1. FINISH: PAINTED W/ BROWN RUST PREVENTATIVE PAINT. 2" THERMOBOND BUILDINGS 2" 4" 2 4" 1 1/2" = 1' SCALE PLATE TO BE 1/4" THICK GRADE A36 WITH 3/4" DIA CUTOUT 1 1/2" = 1' SCALE 1 1/2" = 1' SCALE UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS SHOWN ON THIS DRAWING SHALL HAVE THE FOLLOWING TOLERANCE: FRACTION ANGLE NONE 8/7/13 DJO 1212-960 BOX SKID ASSEMBLY FOR 10'W. OD X 16'L. OD X 9'H. ID BUILDING EAGLE COUNTY 15B1016 PAGE 1 OF 2 6" 3/16" 283" TYP. 1" 543" 2 HOLE LUG TYP. 283" SKID BEAM 3/16" 6" = 1' SCALE PLATE TAPPED FOR 3/8" BOLT 112" 1" 1" 1" 112" 6" = 1' SCALE THERMOBOND BUILDINGS NONE 8/7/13 DJO 1212-960 SKID GROUNDING PLATE DETAIL EAGLE COUNTY 15B1016 PAGE 2 OF 2 ANCHOR BOLTS 3/4" X 6" (GR. 5) ANCHOR BOLTS 3/4" X 6" (GR. 5) 2" 2" OUTLINE OF OUTSIDE OF BUILDING 2 3/4" GRADE OF CONCRETE PIERS 6'-0" MIN. OR 6" BELOW 6 X 6 - 10 X 10 WIRE MESH 1'-0" RD. OR SQ. CL OF CONCRETE PIERS CL OF CONCRETE PIERS CL CL OF CONCRETE PIERS CL OF CONCRETE PIERS PIERS MAY BE 1'-0" ROUND OR SQUARE CL OF CONCRETE PIERS CL OF CONCRETE PIERS NOTES: 1. CONCRETE SHALL ATTAIN A MINIMUM ULTIMATE COMPRESSION STRENGTH OF 4000 PSI WITHIN 28 DAYS. 2. ALL REBAR TO HAVE A MINIMUM OF 2" CONCRETE COVER. 3. TOP OF EACH PIER SHALL BE LEVEL TO WITHIN 1/8" THERMOBOND BUILDINGS THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF THERMOBOND BUILDINGS, LLC. IT IS INTENDED SOLELY FOR THE INFORMATION AND USE OF PARTIES OPERATING AND MAINTAINING THE EQUIPMENT DESCRIBED HEREIN AND MAY NOT BE USED, REPRODUCED OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THERMOBOND BUILDINGS, LLC. 3/8"=1' 8/7/13 DJO 1212-960 PIER FOUNDATION FOR 10'W. OD X 16'L. OD X 9'H. ID BUILDING EAGLE COUNTY P15B1016 PAGE 1 OF 1