M60 LED Direct/Indirect [L6DI] selux.us
Transcription
M60 LED Direct/Indirect [L6DI] selux.us
Customer: Date: Project: Qty: Type: M60 LED Direct/Indirect Order Code: L6DI L6DI - Series - - - - - - - - - - - - L6DI M60 LED Direct/Indirect Direct Light Engine 1A351,2 642lm/8.7W per foot Indirect Light 1A35 632lm/8.7W Engine YEAR ARRA Compliant 1A201,2 565lm/7.5W per foot 475lm/6.2W per foot 556lm/7.5W per foot 1A25 1A20 CCT 27 30 35 40 Direct Shielding LW MI Indirect Shielding LW Mounting C RS W Nominal Fixture Length 02 Finish WH BK SV Voltage 120 277 UNV 2700K 1,2 1,2 467lm/6.2W per foot 3000K 3500K Values calculated from a 4’ fixture @4000K using LW Shielding and DIM driver. For additional information please see page 2. 1 385lm/5W per foot 1A30 Mixed output available 4’ and up, see page 7 for details. 2 1,2 379lm/5W per foot 4000K LED Optimized Clear Lens with white lens Microprism LED Optimized white lens S Cable 2 ft. Swivel Stem 03 3 ft. 04 4 ft. 05 5 ft. Rigid Stem 06 6 ft. 07 7 ft. Wall Mount 08 8 ft. 09 9 ft. 10 10 ft. 11 11 ft. 12 12 ft. Individual fixtures, Runs and Configurations are supplied in nominal lengths to ensure full, even, illumination. See pages 2 thru 5 for additional details. White Black Silver SP Specify Premium Color 120 Volt 277 Volt 120 thru 277 50/60hz capable Driver DIM3 DM3 DML3 DMD3 Fixture Options DL5 FS5 SS 5 C96 Emergency Options EC7 0-10V (Linear) Damp Location Rated eldoLED eldoLED SOLOdrive 0-10V SOLOdrive 0-10V (Linear) (Logarithmic) In-Line Fuse Separate Switching eldoLED DALI (Logarithmic) DC23,4 Lutron 2-Wire XX Runs (over 12’) are available in 1’ nominal increments, round up to the nearest foot and replace the “xx” with the # (i.e. 13=13’ nominal) Custom colors are available, Please consult factory DC33 Lutron 3-Wire DCE3 Lutron Eco-System 90 CRI 3 See page 6 for full details 120V only 4 See page 7 for full details and restrictions For 2700K & 4000K consult factory 5 6 See page 7 for full details and restrictions 7 Emergency Circuit Wiring Configuration IL908 Lit Horizontal Options 90° Corner 5 1A251,2 per foot 1,2 LED WARRANTY 1A301,2 IT909 Lit “T” section IX908 See page 8 for full details and restrictions 8 Lit “X” section ADA Compliant Selux Corporation © 2016, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Page 1 of 9 (Rev. 05/2016) L60_DI_ss_v2.1 M60 LED Direct/Indirect 4 3/4” (120mm) 2 1/4” (56mm) LW lens shown for reference 2 /” 3 8 (60mm) Construction: Electrical/Performance: Luminaire Finish: Housing - Continuous, low copper 6063-T6 extruded aluminum profile with aluminum endcaps, available as Individual fixtures (up to 12’) or Runs. LED Light Engine - Brand-name mid-power LEDs create a high efficiency LED light engine able to provide a lumen maintenance of 96% at 25,000 hours and 93% at 60,000 hours per TM-21 report. Powder Coat - All Selux luminaries are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accordance with test specifications for coatings from ASTM and PCI. LED Life - Calculated L70 greater than 386,000 hours and Reported L70 greater than 60,000 hours @ 25°C per TM-21 All products undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention. Geartray - Low copper 6063-T6 extruded aluminum profile. Shielding - Extruded, impact resistant acrylic lens: - LED optimized white lens (LW) - Clear lens with microprism (MI) Mounting(s)- 1/16” Aircraft Cable, Ø5/8” Swivel or Rigid Steel Stem, Wall Bracket, (see pages 3 thru 5 for details). ** Cable, Stem and Wall mountings may not be symmetrical for Runs and Configurations due to the use of modular housing lengths. If symmetrical suspensions are required please consult the factory. Standard Luminaire lengths - All standard luminaires are supplied in nominal lengths to ensure full, even, illumination. Runs and Configurations are available in approximately 1’ increments starting at the nominal 12’ fixture length. ** Individual luminaires are not joinable in the field. Exact length luminaires - Individual luminaires, runs, and configuration are available in exact lengths to meet your project needs. Please consult factory with you requirements. ** Lens luminance may soften at the very ends of the straight sections for exact length luminaires. Delivered Lumens - Due to LED manufacturer’s tolerances the listed output has a ±5% tolerance. For outputs based on different shielding or CCT please see photometry section at the end. CCT - Available in 2700K, 3000K, 3500K and 4000K, tolerance within a 3-step MacAdam ellipse. CRl - Min. 80. Optional 90CRI - for 2700K and 4000K, consult factory. All Drivers - High efficiency, constant current, soft start, Electronic Class 2 with a PFC>0.90. For more detailed information on the available drivers please see page 6. Thermal Performance: Ambient Operating Temperature - Luminaires suitable for Max. ambient temperature of 35° C (95° F) for all drivers. Min. ambient temperature of: -20°C (-4°F) for DM, DIM, DML and DMD drivers. 0°C (32°F) for the DC2, DC3 and DCE drivers. L60 Joiner(s) - Runs and configurations are supplied in multiple housing that are joined together in the field using the supplied L60 Joining System. This allows ease of installation and ensures a uniform appearance (see page 7 for detail). Standard interior colors are White (WH), Black (BK), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide. Warranty: 5 Year Limited LED Luminaire Warranty Selux offers a 5 Year Limited Warranty to the original purchaser that the M60 series LED luminaire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed according to Selux instructions and operated within the Ambient Temperature. For additional details and exclusions, see “Selux Terms and Condition of Sale.” Certifications and Compliance: NRTL - For Dry and Damp location (I.E. cULus; cCSAus) ADA Compliant ARRA Compliant RoHS Compliant Selux Corporation © 2016, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Page 2 of 9 (Rev. 05/2016) L60_DI_ss_v2.1 M60 LED Direct/Indirect Cable Mounting (C) Cable Mounting (C) 1. Ø 1/16” Aircraft Cable with chrome gripper for easy adjustment (48” max. from ceiling to luminaire). Cable Mounting (C) - Dimensions Nominal Length “A” Housing Length * “B” (Ref.) End Suspensions “C” Mid. Suspension “D” Feed Location “E” Illuminated Length Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch 02 (2 ft.) 2' - 1/4" 616 0' - 7/8" 22 1' - 10 1/2" 572 0' - 3/8" 9 1' - 9" MM 534 03 (3 ft.) 3' - 5/16" 923 0' - 7/8" 22 2' - 10 5/8" 879 0' - 3/8" 9 2' - 7 5/8" 803 04 (4 ft.) 3' - 11 7/16" 1205 0' - 7/8" 22 3' - 9 11/16" 1161 0' - 3/8" 9 3' - 8 3/16" 1123 1428 05 (5 ft.) 4' - 11 7/16" 1510 0' - 7/8" 22 4' - 9 11/16" 1466 0' - 3/8" 9 4' - 8 1/4" 06 (6 ft.) 5' - 11 7/16" 1815 0' - 7/8" 22 5' - 9 11/16" 1770 0' - 3/8" 9 5' - 8 1/4" 1733 07 (7 ft.) 6' - 11 7/16" 2119 0' - 7/8" 22 6' - 9 11/16" 2075 0' - 3/8" 9 6' - 8 3/16" 2037 08 (8 ft.) 7' - 11 7/16" 2424 0' - 7/8" 22 7' - 9 11/16" 2380 0' - 3/8" 9 7' - 8 3/16" 2342 09 (9 ft.) 8' - 11 7/16" 2729 0' - 7/8" 22 8' - 9 11/16" 2685 0' - 3/8" 9 8' - 8 3/16" 2647 10 (10 ft.) 9' - 11 7/16" 3034 0' - 7/8" 22 9' - 9 11/16" 2990 0' - 3/8" 9 9' - 8 1/4" 2952 11 (11 ft.) 10' - 11 7/16" 3339 0' - 7/8" 22 10' - 9 11/16" 3294 0' - 3/8" 9 10' - 8 1/4" 3257 12 (12 ft.) 11' - 11 7/16" 3643 0' - 7/8" 22 11' - 9 11/16" 3599 0' - 3/8" 9 11' - 8 3/16" 3561 *Dimension(s) rounded to the nearest 1/16” with a ± 1/16 (1mm) tolerance. L6DI Cable (C) Suspension Detail L6DI Cable (C) Suspension Detail (Feed location(s) only) (Non-Feed location(s) only) Outlet box for feed only (by others) Cross bar with 1/4-20 rod and ground screw 2x Outlet box screws (by others) 1/4”- 20 Threaded rod (supplied & installed in the field by others) 1/4” x 5” diameter canopy (White) 1/4” x 2” diameter canopy (White) Cord strain relief bushing 1/4-20 Slip ring coupler 1/16” Aircraft cable 1/4-20 Slip ring coupler Chrome gripper Feed cord (White) Luminaire 1/16” Aircraft cable 2x White cable stay Chrome gripper Luminaire Selux Corporation © 2016, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Page 3 of 9 (Rev. 05/2016) L60_DI_ss_v2.1 M60 LED Direct/Indirect Stem Mounting (S & RS) 48” Swivel Stem (S) & Rigid Stem (RS) Mounting 1. Ø 5/8” Swivel Stem provides 30° swivel and can be cut in field (48” max. from ceiling to luminaire). 2. Ø 5/8” Rigid Stem is fixed and is not able to be cut/adjusted in field (48” max. from ceiling to luminaire). Swivel (S) & Rigid Stem (RS) Mountings - Dimensions Nominal Length “A” Housing Length Feet/Inch * “B” (Ref.) End Suspensions MM Feet/Inch MM “C” Mid. Suspension Feet/Inch “D” Feed Location MM Feet/Inch MM “E” Illuminated Length Feet/Inch MM 02 (2 ft.) 2' - 1/4" 616 0' - 7/8" 22 1' - 10 1/2" 572 0' - 3/8" 9 1' - 9" 534 03 (3 ft.) 3' - 5/16" 923 0' - 7/8" 22 2' - 10 5/8" 879 0' - 3/8" 9 2' - 7 5/8" 803 04 (4 ft.) 3' - 11 7/16" 1205 0' - 7/8" 22 3' - 9 11/16" 1161 0' - 3/8" 9 3' - 8 3/16" 1123 05 (5 ft.) 4' - 11 7/16" 1510 0' - 7/8" 22 4' - 9 11/16" 1466 0' - 3/8" 9 4' - 8 1/4" 1428 06 (6 ft.) 5' - 11 7/16" 1815 0' - 7/8" 22 5' - 9 11/16" 1770 0' - 3/8" 9 5' - 8 1/4" 1733 07 (7 ft.) 6' - 11 7/16" 2119 0' - 7/8" 22 6' - 9 11/16" 2075 0' - 3/8" 9 6' - 8 3/16" 2037 08 (8 ft.) 7' - 11 7/16" 2424 0' - 7/8" 22 7' - 9 11/16" 2380 0' - 3/8" 9 7' - 8 3/16" 2342 09 (9 ft.) 8' - 11 7/16" 2729 0' - 7/8" 22 8' - 9 11/16" 2685 0' - 3/8" 9 8' - 8 3/16" 2647 10 (10 ft.) 9' - 11 7/16" 3034 0' - 7/8" 22 9' - 9 11/16" 2990 0' - 3/8" 9 9' - 8 1/4" 2952 11 (11 ft.) 10' - 11 7/16" 3339 0' - 7/8" 22 10' - 9 11/16" 3294 0' - 3/8" 9 10' - 8 1/4" 3257 12 (12 ft.) 11' - 11 7/16" 3643 0' - 7/8" 22 11' - 9 11/16" 3599 0' - 3/8" 9 11' - 8 3/16" 3561 *Dimension(s) rounded to the nearest 1/16” with a ± 1/16 (1mm) tolerance. L6DI Swivel Stem (S) Suspension Detail L6DI Rigid Stem (RS) Suspension Detail (feed wires through stem supplied by others) (feed wires through stem supplied by others) Outlet box (supplied & installed by others) 3/8” IP Crossbar with ground screws 3/8” IP nipple (supplied & installed by others) Outlet box (supplied & installed by others) Cotter pin Square nut Hemispherical assembly Suspension hickey 1 7/16” x 5” diameter canopy (white) 3/8” IP steel swivel stem (white) Dress nut Luminaire Square nut Square nut 1/4” x 5” diameter Canopy (white) Canopy securing screw 3/8” IP steel stem (white) Dress nut Luminaire Square nut Selux Corporation © 2016, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Page 4 of 9 (Rev. 05/2016) L60_DI_ss_v2.1 M60 LED Direct/Indirect Wall Mounting (W) Wall (W) Mount - Dimensions “A” Housing Length Nominal Length * “B” (Ref.) End Suspensions “C” Mid. Suspension “D” Feed Location Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch 02 (2 ft.) 2' - 1/4" 616 0' - 3 1/8" 79 1' - 6 1/16" 458 0' - 3 1/8" MM 79 03 (3 ft.) 3' - 5/16" 923 0' - 6 1/8" 156 2' - 1/8" 612 0' - 6 1/8" 156 04 (4 ft.) 3' - 11 7/16" 1205 0' - 6 1/8" 156 2' - 11 3/16" 894 0' - 6 1/8" 156 05 (5 ft.) 4' - 11 7/16" 1510 0' - 6 1/8" 156 3' - 11 3/16" 1199 0' - 6 1/8" 156 06 (6 ft.) 5' - 11 7/16" 1815 0' - 6 1/8" 156 4' - 11 3/16" 1504 0' - 6 1/8" 156 07 (7 ft.) 6' - 11 7/16" 2119 0' - 6 1/8" 156 5' - 11 3/16" 1808 0' - 6 1/8" 156 156 08 (8 ft.) 7' - 11 7/16" 2424 0' - 6 1/8" 156 6' - 11 3/16" 2113 0' - 6 1/8" 09 (9 ft.) 8' - 11 7/16" 2729 0' - 6 1/8" 156 7' - 11 3/16" 2418 0' - 6 1/8" 156 10 (10 ft.) 9' - 11 7/16" 3034 0' - 6 1/8" 156 8' - 11 3/16" 2723 0' - 6 1/8" 156 11 (11 ft.) 10' - 11 7/16" 3339 0' - 6 1/8" 156 9' - 11 3/16" 3028 0' - 6 1/8" 156 12 (12 ft.) 11' - 11 7/16" 3643 0' - 6 1/8" 156 10' - 11 3/16" 3332 0' - 6 1/8" 156 *Dimension(s) rounded to the nearest 1/16” with a ± 1/16 (1mm) tolerance. Wall Mount (W) (Covers a 4x4 or 2x4 J-Box) 1. Aluminum wall bracket (by Selux) 2. 4”x4” or 2”x4” J-Box at feed location (supplied and installed by others). 3. 1/4-20 Threaded rod, 1/4-20 lock washer and 1/4-20 nut required to anchor the wall bracket. Mounting hardware supplied and installed to code by others. 4” (102mm) 4” (102mm) 1” (25mm) 3 3/8” (85mm) Selux Corporation © 2016, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Page 5 of 9 (Rev. 05/2016) L60_DI_ss_v2.1 M60 LED Direct/Indirect Drivers: eldoLED SOLOdrive 0-10V linear dimming (DM) Luminaires supplied with SOLOdrive 0-10V dimming driver for linear dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory. Maximum inrush current per drive is 30mA2s & 0-10V control current is maximum 2mA per driver. LUTRON 2-wire dimming (DC2) Luminaires supplied with A-series 2-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%. Inrush current per driver <2A. eldoLED SOLOdrive 0-10V logarithmic dimming (DML) Luminaires supplied with SOLOdrive 0-10V dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory. Maximum inrush current per drive is 30mA2s & 0-10V control current is maximum 2mA per driver. LUTRON 3-wire dimming (DC3) Luminaires supplied with A-series 3-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%. Inrush current per driver <2A. eldoLED SOLOdrive DALI dimming (DMD) Luminaires supplied with SOLOdrive DALI dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory. Maximum inrush current per drive is 30mA2s. LUTRON Ecosystem dimming (DCE) Luminaires supplied with A-series EcoSystem (4 wire, digital link) dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%. Inrush current per driver <2A. * For control recommendations for eldoLED drivers, please consult eldoLED. * For control recommendations and system layout for Lutron drivers, please contact Lutron. Driver Quantity DIM, DM, DML & DMD drivers DC2, DC3, & DCE drivers 2 ft. 3 ft. 4 ft. 5 ft. 6 ft. 7 ft. 8 ft. 9 ft. 10 ft. 11 ft. 12 ft. RUN 1 1 2 2 2 3 4 4 4 5 6 Approximately 2 drivers per 4 ft. N/A 2 2 3 4 4 4 5 6 6 6 Consult Factory Wiring Diagrams 0-10V linear (DIM) 0-10V linear eldoLED SOLOdrive (DM) 0-10V logarithmic eldoLED SOLOdrive (DML) DALI eldoLED SOLOdrive (DMD) standard DIM, DM, DML & DMD DALI DALI Selux Corporation © 2016, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Page 6 of 9 (Rev. 05/2016) L60_DI_ss_v2.1 M60 LED Direct/Indirect Fuse (FS) - Fusing, luminaires supplied with a in-line fuse located on the hot wire for each feed (supplied with an 8A slow burn fuse). Mixed Output - Luminaires have ability to offer mixed light engines (i.e. 1A35 direct and 1A25 indirect) starting at 4’ and then in 2’ steps (i.e. 6’, 8’, 10’, 12’ ... ). Damp Location (DL) -Luminaires are suitable for use in damp location(s). Examples of such locations include protected areas under canopies, marquees, roofed porches, and similar locations where the fixture(s) are protected from direct contact with rain, snow, or excessive moisture (such as ocean spray). Interior locations include areas subject to moderate degrees of moisture, such as basements and certain barns and cold storage buildings. All solder points on LED boards are conformal coated. The phosphor layer of the LEDs is free of coating to avoid hazing. Separate Switching (SS) - Luminaire available with the Direct side switched separately from the Indirect side starting at the 4’ nominal length and then in 2’ nominal steps, i.e. 6’, 8’, 10’, 12’, etc... Luminaire is intended to be wired to the same panel/breaker (not intended for Emergency use). * If the project requires different separate switching than outlined above please consult the factory. Emergency Circuit (EC) - Available starting at 4’ nominal length and then in 2’ steps (I.E. 6’, 8’, 10’, 12’…). Luminaires to have the first 4’nominal length operated on separate EM circuit by default to meet the required “Life Safety Code” (NFPA 101). If a different configuration is needed please consult the factory. Luminaires with EC option compliant to UL 924. EC luminaires are intended to be wired to separate panels/breakers for emergency use. Joiner System Standard for Runs & Configurations Selux Corporation © 2016, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Page 7 of 9 (Rev. 05/2016) L60_DI_ss_v2.1 M60 LED Direct/Indirect Standard Direct/Indirect shapes/configurations: Listed below are the minimum lengths and details for standard shapes. These standard shapes can be combined with each other and/or the standard luminaire lengths, ensuring full even illumination. If you have any questions, please consult the factory. The minimum standard lengths for “L” shapes: - IL90 or V90 open shapes is 4’ x 4’ nominal (example: leg, 90, leg) - IL90 or V90 closed shapes is 6’ x 6’ nominal (example: 90, leg, 90) (E xception is that the IL90 & V90’s can be joined directly to provide a 4’ x 4’ nominal shape) The minimum standard lengths for “T” & “X” shapes: - IT90 = 4’ nominal on the short leg and 8’ nominal on the long side - IX90 = 8’ nominal for either direction Project Specific Direct/Indirect shapes/configurations: Selux is capable of supplying a wide range of project solutions including different shapes, angles, and sizes to meet the project requirements. Due to the complex nature of these project specific layout(s) we ask that you please consult the factory with the project requirements for review. Direct/Indirect Lit Corner and Section - Dimensions IL90 IT90 Feet/Inch MM “A” Housing (Outside) 2' - 1 1/4" 642 “A1” Housing (Inside) 1' - 10 15/16" 582 IX90 Feet/Inch MM Feet/Inch MM “B” Housing 2' - 1 1/4" 642 * “B1” Ref. 2' - 1/8" 612 “C” Housing 4' - 3/16" 1224 * “C1” Ref. 2' - 1/8" 612 “D” Housing 4' - 3/16" 1224 * “D1” Ref. 2' - 1/8" 612 *Dimension(s) rounded to the nearest 1/16” with a ± 1/16 (1mm) tolerance. Selux Corporation © 2016, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Page 8 of 9 (Rev. 05/2016) L60_DI_ss_v2.1 M60 LED Direct/Indirect Photometry LW Optics / 69W LED / 4000K CCT (x2) 910 Link to photometry (IES & PDF files) 682 455 227 Catalog #: L6DI-1A35-1A35-40-LW-LW-04-120 Report #: 742732-1 Delievered Lumens: 5097 Input Watts: 69.3W Efficacy: 74 Power Factor: 0.994 Total Harmonic Distortion: 5.14 CCT: 3926K CRI: 84.1 Max Candela: 909.5 @ 2.5° from Vertical Spacing Criterion (0-180): N/A Spacing Criterion (90-270): N/A Spacing Criterion (Diagonal): N/A CCT Multiplier 4000K 1.000 3500K 0.968 3000K 0.987 2700K 0.939 2 1 Maximum Candela = 909.512 Located At Horizontal Angle = 90, Vertical Angle = 2.5 # 1 - Vertical Plane Through Horizontal Angles (90 - 270) # 2 - Vertical Plane Through Horizontal Angles (0 - 180) 90 CRI Multiplier 4000K 0.884 3500K 0.924 3000K 0.880 CCT and CRI multipliers apply to the photometry, IES files, and per foot values listed on page one (light engine). Light Engine Multiplier Engine Lumens Watts 1A35 1.00 1.00 1A30 0.88 0.86 1A25 0.74 0.71 1A20 0.60 0.58 Light engine multiplier supplied for per foot values listed on page one (light engine). Selux Corporation © 2016, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Page 9 of 9 (Rev. 05/2016) L60_DI_ss_v2.1
Similar documents
M100 LED Direct [L10] selux.us
Tiger Drylac certified facility and are tested in
accordance with test specifications for coatings
from ASTM and PCI.