Lossnay Heat Recovery Ventilation
Transcription
Lossnay Heat Recovery Ventilation
Lossnay Heat Recovery Ventilation Clean, fresh air for a healthier, drier and warmer home. Balanced Pressure Home Ventilation. Made in Japan, designed for New Zealand Conditions. Lossnay Fresh Air Heat Recovery Ventilation They say home is where the heart is. Because we spend so much time at home, the heart of the home should therefore be as healthy as possible for your whole family. Clean, fresh air is paramount to good health and overall wellbeing. Ventilation and airtight building design Lossnay is designed for today’s modern homes Creating a healthy living environment is important when The word “Lossnay” originated from the Japanese word renovating or building a new home – you will want the perfect “Loss-Nai”, meaning “No Loss”. Lossnay is a patented indoor climate year round. In addition to efficient heating and Balanced Pressure Heat Recovery Ventilation System cooling, this should include the optimum amount of circulating specifically designed for more airtight homes built to the fresh air. current New Zealand Building Code. It also complies with the Current building regulations now demand homes to be built more airtight as they are subjected to higher insulation standards. But the option of leaving doors or windows open to allow more fresh air to enter is often not the solution from an outdoor noise or security perspective. Ventilation Standard NZS4303:1990 that specifically requires ventilation systems to draw fresh air from the outside and not the roof space to achieve acceptable indoor air quality. Bring fresh air in without draughts The Lossnay VL220 is an advanced Heat Recovery Ventilation Ventilation, condensation and moisture management System that brings in filtered fresh outdoor air to replace stale The lack of natural ventilation due to airtight spaces can lead to fluctuations when additional fresh air is introduced. This is the build-up of moisture laden stale air within the home. This is important as too many air changes will lead to dramatic drops in the perfect breeding ground for mould that can trigger allergy or indoor temperature that require unnecessary additional heating. indoor air. The optimum number of air changes are regulated to ensure there are no draughts, whilst minimising temperature respiratory problems. Furthermore, mould and dampness can also compromise both building materials as well as furnishings inside the home. Common places for mould to grow not only include window sills, curtains and carpets, but also walls and damp areas such as laundries, kitchens and bathrooms. Conventional positive pressure ventilation systems are not designed to deal with the additional moisture load from these damp areas. Maximise heat recovery even from damp areas Because of its unique highly efficient heat recovery ability, the system maximises recovery of the available heat energy from outgoing stale air, as well as heat energy contained in moist air from damp areas such as bathrooms, toilets and kitchens. Pre-warm or cool air to save on your power bill This recovered heat energy is then utilised to pre-warm incoming air in winter or pre-cool this air in summer – ultimately saving you on your heating or cooling bill. The end result is a healthier, drier and warmer home. The Mitsubishi Electric Lossnay Difference What makes the Balanced Pressure Lossnay VL220 Heat Recovery Home Ventilation System from Mitsubishi Electric so different from other systems is our advanced Diamond Lossnay Core at the heart of the heat exchanger. Unlike ordinary positive pressure ventilation systems, the patented Diamond Core and built in drain outlet allows the FEATURES system to also be effectively utilised in damp areas such as Draws in clean fresh air from the outside not the attic areas at the same time. Removes stale air from the inside The available energy is absorbed and re-used to provide Controls moisture by managing humidity levels Heat recovery from stale outgoing air Efficient heat recovery from damp areas Whisper quiet operation from 14dBA Balanced Pressure Ventilation kitchens, bathrooms and toilets to help extract moisture and maximise recovery of additional heat energy from these damp pre-warming in winter or pre-cooling in summer, rather than going to waste by directly transferring this air outside. In doing so, moisture build up in your home is minimised while healthy humidity levels are maintained and managed. The end result: your home is ventilated with fresh, filtered and clean pre-warmed (or cooled) air at the same time whilst maintaining optimum humidity levels for healthy living. The system is super energy efficient and designed specifically to be whisper quiet. Why outside air, not attic air? Not all air is created equal. Lossnay only draws fresh air from the outside specifically – it does not draw air from the attic. The absence of significant air movement common in attics means the air is likely to be stale. In addition, build-up of dust, dirt and other contaminants such as mould, insect and rodent droppings makes this air much harder to filter before it is distributed through your home. This is why the Balanced Pressure Lossnay system specifically utilises direct fresh air instead. Circulates fresh air without draughts Designed for modern homes that are more airtight How It Works The Balanced Pressure Lossnay Heat Recovery Ventilation System removes stale, dirty air and draws in fresh air from outside. Lossnay also recovers heat energy from the air being transferred to pre-warm (or pre-cool) the fresh air being drawn into your home. The VL220 model is ideal for small to medium sized homes between 52m2 and 192m2. 1. The stale air extracted from your home is Return Air (RA). Return Air can contain high levels of CO2, odours and other pollutants. This Return Air stream also contains heat energy that Lossnay can recover, which is not the case with other positive pressure ventilation systems. 2. As the stale Return Air is removed, Lossnay’s core ‘recovers’ the useful heat energy from it. The air is then exhausted (EA) outside along with the unwanted pollutants. 3. Outdoor Air (OA) is introduced to provide fresh clean air. It is first filtered, then passed through the Lossnay core. This allows it be pre-heated in winter (or pre-cooled in summer) using the energy recovered from the Return Air. 4. Supply Air (SA) then enters your house as fresh pre-heated or pre-cooled air. EXTRACTS STALE AIR Extracts stale air removing toxins and reducing humidity. SUPPLIES FRESH AIR Supplies fresh air increasing the oxygen levels in the home and assists with managing the build up of moisture. HEAT ENERGY RECOVERY Recovers up to 86% of the heat energy from the outgoing air to preheat the incoming air, saving you money. THE DIAMOND LOSSNAY CORE How Fresh Air Heat Energy Recovery Works EA Outdoors St al e Stale dirty indoor air (Exhausted Air) Indoors Fr e s SA h Fresh air into home (Supply Air) Partition plate Spacer plate e h al Fresh air introduction (Outdoor Air) Fr e s St OA RA Stale air removed from home (Return Air) Balanced Pressure Heat Recovery Ventilation Benefits Ventilating your home is vital as it maintains air quality and reduces moisture, creating a healthier and more comfortable environment. The Mitsubishi Electric Lossnay System is a patented heat recovery ventilation solution that uses fresh air (not attic air) to ventilate your home. The system works by extracting stale air from inside your house and replacing it with allergen reduced fresh air from outside. Improved Air Quality Creates a Healthier Home By drawing in fresh outdoor air, indoor air Filtered fresh air improves air quality for allergy quality is improved as high levels of CO2, and asthma sufferers. odours and other pollutants are removed from your home. Fresh Air Without Open Windows Energy Efficient Lossnay allows you to have a well-ventilated Incoming fresh air is pre-warmed so your home without the need to open windows. This heating system isn’t required to work as hard to improves the safety of your home and family reach desired temperature. This is highly energy and means outdoor noise is minimised. efficient, and can help reduce heating bills. Retains Heat Lossnay’s unique Heat Recovery Technology Assists Moisture and Condensation Control collects up to 86% of the heat energy in Lossnay effectively reduces moisture in your outgoing air which is then used to pre-warm or home by directly removing stale air that causes cool the fresh air vented in. condensation via the Lossnay core. Balanced Pressure, No Draughts Easy Control At Your Finger Tips Lossnay is specifically designed for more An intuitive wall controller with easy to read airtight homes built to the current New Zealand LCD display comes standard. Fan speed, night building code, bringing in the optimum amount set back and 24-hour and weekly timers can of fresh air without creating draughts and easily be customised and programmed with up minimising indoor temperature fluctuations. to 8 stop and start patterns per day. Quietest in its Class Easy To Clean At an ultra quiet 14dBA in low fan speed, The standard filters can be removed for the Lossnay VL220 is the quietest system in regular cleaning to keep the unit in optimal its class. working condition. Positive Pressure roof cavity ventilation VS Balanced Pressure Fresh Air Heat Recovery Ventilation These systems typically force air into the Balanced ventilation mechanically removes home from the attic space and specifically stale air and replaces it with clean, fresh air require gaps in the building structure at the same rate. It is also fitted with a heat (common in older homes) to facilitate air exchanger that actively recovers heat energy displacement. As these systems are not from the outgoing stale indoor air to pre-warm designed to recover heat energy to help incoming fresh air. As such, the need for pre-warm incoming air, colder incoming air will require more additional heating – adding to your power bill. additional heating of fresh air is reduced. This Air goes in and gets trapped system is specifically designed for modern homes that are of more airtight construction. Fresh air goes in while stale air is pushed out Lossnay VL220 Technical Specifications Dimensions 174 119 33 EA (Exhaust air) Duct connecting flange (EA) 234 31 320 362 98 124 146 Duct connecting flange (OA) 199 775(Ceiling suspension fixture) 815 Exhaust air filter case Auxiliary fixture Lossnay - Residential Model Drain pan VL-220CZGV-E Ventilation modes Lossnay Sizing Guide VL-220CZGV-E Air to Air sensible heat exchanger Heat exchange element material Specially treated non permeable resin core Operating range OA temperature -5°C* to +40°C, 80%RH Weight (kg) 31 Electrical power supply 220-240 V / 50Hz Fan speed 220V / 60 Hz Fan Speed 4 Fan Speed 3 Fan Speed 2 Fan Speed 1 Input power (W) 80 35 18.5 8.5 230 165 120 65 64 46 33 18 164 84 44 13 Temperature exchange efficiency (%) 82 84 85 86 Noise (dB) (Measured at 1.5m under the centre of an anechoic chamber) 31 25 19 14 (m /h) 3 (L/s) External static pressure (Pa) Duct size (Unit mm) Supply air filter case Bypass† Heat recovery mode Heat exchange system Air volume OA (Outdoor air) 20 720 151 Type 8 80 8 RA1 (Return air) Duct connecting flange (RA1) 295 271 885 229 SA (Supply air) 850 Duct connecting flange (SA) 139 86 Drain outlet 116 Ceiling suspension fixture 31 Power supply cable opening 143 848(Ceiling suspension fixture) Sample Installation 150mm House Size m² Ceilingm²Height 25 2.4 50 2.4 75 2.4 100 2.4 125 2.4 150 2.4 175 2.4 190 2.4 House Air Volume m³ 60 120 180 240 300 360 420 456 NZ 4303 m³/hr 21 42 63 84 105 126 147 160 BS Standard m³/hr 30 60 90 120 150 180 210 228 Fan Speed House Size m² Ceiling Height m² 25 2.7 50 2.7 75 2.7 100 2.7 125 2.7 150 2.7 175 2.7 House Air Volume m³ 68 135 203 270 338 405 473 NZ 4303 m³/hr 24 47 71 95 118 142 166 BS Standard m³/hr 34 68 102 135 169 203 237 Fan Speed 1 1 2 2 3 4 4 4 1 2 2 3 4 4 4 House sizing guide is based on British Standard for ventilation requiring 0.5 Air changes per hour. New Zealand standard (NZ4303) is 0.35 air changes per hour *Return Air will continue to operate from -5°C to -15°C. Optional VL220 Extras Filters Exhaust fans The VL220 Ventilation system is supplied with 2 standard (G3) Mitsubishi Electric offer a range of energy efficient exhaust replacement filters that can be washed up to 4 times. fans that feature low vibration and quiet operation – ideal for The 2 exhaust Filters can be upgraded to non-washable medium the extraction of moisture and contaminants in bathrooms and efficiency filters (G4). kitchens. These exhaust fans are designed to specifically work The 2 supply filters can be upgraded to non-washable high in harmony with the Lossnay VL220 system. efficiency filters (M6). † Bypass Damper When the outdoor temperature is cooler than the indoor 5 Year Warranty temperature (and vice versa) the optional damper allows a The Mitsubishi Electric Lossnay product in this brochure comes with bypass of the heat exchanger should temperature conditions a full 5 year parts and labour warranty. Warranty conditions apply. reach set levels. www.mitsubishi-electric.co.nz WELLINGTON AUCKLAND CHRISTCHURCH HEAD OFFICE BRANCH BRANCH 1 Parliament Street Unit 1, 4 Walls Road 44 Halwyn Drive PO Box 30772 PO Box 12726 PO Box 16904 Lower Hutt 5040 Penrose, Auckland 1642 Hornby, Christchurch 8441 Phone (04) 560 9147 Phone (09) 526 9347 Phone (03) 341 2837 Fax (04) 560 9133 Fax (09) 526 9369 Fax (03) 341 2838 All features and specifications are subject to change and amendment at anytime. May 2016. Unit (mm)