Lossnay Heat Recovery Ventilation

Transcription

Lossnay Heat Recovery Ventilation
Lossnay Heat Recovery Ventilation
Clean, fresh air for a healthier, drier and warmer home.
Balanced Pressure Home Ventilation. Made in Japan, designed for New Zealand Conditions.
Lossnay Fresh Air Heat Recovery Ventilation
They say home is where the heart is. Because we spend so much time at home, the heart of the home
should therefore be as healthy as possible for your whole family. Clean, fresh air is paramount to good
health and overall wellbeing.
Ventilation and airtight building design
Lossnay is designed for today’s modern homes
Creating a healthy living environment is important when
The word “Lossnay” originated from the Japanese word
renovating or building a new home – you will want the perfect
“Loss-Nai”, meaning “No Loss”. Lossnay is a patented
indoor climate year round. In addition to efficient heating and
Balanced Pressure Heat Recovery Ventilation System
cooling, this should include the optimum amount of circulating
specifically designed for more airtight homes built to the
fresh air.
current New Zealand Building Code. It also complies with the
Current building regulations now demand homes to be built
more airtight as they are subjected to higher insulation
standards. But the option of leaving doors or windows open to
allow more fresh air to enter is often not the solution from an
outdoor noise or security perspective.
Ventilation Standard NZS4303:1990 that specifically requires
ventilation systems to draw fresh air from the outside and not
the roof space to achieve acceptable indoor air quality.
Bring fresh air in without draughts
The Lossnay VL220 is an advanced Heat Recovery Ventilation
Ventilation, condensation and moisture
management
System that brings in filtered fresh outdoor air to replace stale
The lack of natural ventilation due to airtight spaces can lead to
fluctuations when additional fresh air is introduced. This is
the build-up of moisture laden stale air within the home. This is
important as too many air changes will lead to dramatic drops in
the perfect breeding ground for mould that can trigger allergy or
indoor temperature that require unnecessary additional heating.
indoor air. The optimum number of air changes are regulated
to ensure there are no draughts, whilst minimising temperature
respiratory problems. Furthermore, mould and dampness can
also compromise both building materials as well as furnishings
inside the home.
Common places for mould to grow
not only include window sills,
curtains and carpets, but also
walls and damp areas such as
laundries, kitchens and bathrooms.
Conventional positive pressure
ventilation systems are not designed
to deal with the additional moisture
load from these damp areas.
Maximise heat recovery even from damp areas
Because of its unique highly efficient heat recovery ability, the
system maximises recovery of the available heat energy from
outgoing stale air, as well as heat energy contained in moist air
from damp areas such as bathrooms, toilets and kitchens.
Pre-warm or cool air to save on your power bill
This recovered heat energy is then utilised to pre-warm
incoming air in winter or pre-cool this air in summer –
ultimately saving you on your heating or cooling bill. The end
result is a healthier, drier and warmer home.
The Mitsubishi Electric Lossnay Difference
What makes the Balanced Pressure Lossnay VL220 Heat Recovery Home Ventilation System from
Mitsubishi Electric so different from other systems is our advanced Diamond Lossnay Core at the heart
of the heat exchanger.
Unlike ordinary positive pressure ventilation systems, the
patented Diamond Core and built in drain outlet allows the
FEATURES
system to also be effectively utilised in damp areas such as

Draws in clean fresh air from the
outside not the attic
areas at the same time.


Removes stale air from the inside
The available energy is absorbed and re-used to provide

Controls moisture by managing
humidity levels

Heat recovery from stale
outgoing air

Efficient heat recovery from
damp areas

Whisper quiet operation from
14dBA


Balanced Pressure Ventilation
kitchens, bathrooms and toilets to help extract moisture and
maximise recovery of additional heat energy from these damp
pre-warming in winter or pre-cooling in summer, rather than
going to waste by directly transferring this air outside. In doing
so, moisture build up in your home is minimised while healthy
humidity levels are maintained and managed.
The end result: your home is ventilated with fresh, filtered
and clean pre-warmed (or cooled) air at the same time whilst
maintaining optimum humidity levels for healthy living. The
system is super energy efficient and designed specifically to be
whisper quiet.
Why outside air, not attic air?
Not all air is created equal. Lossnay only draws fresh air from
the outside specifically – it does not draw air from the attic. The
absence of significant air movement common in attics means
the air is likely to be stale. In addition, build-up of dust, dirt and
other contaminants such as mould, insect and rodent droppings
makes this air much harder to filter before it is distributed
through your home. This is why the Balanced Pressure Lossnay
system specifically utilises direct fresh air instead.
Circulates fresh air without
draughts
Designed for modern homes that
are more airtight
How It Works
The Balanced Pressure Lossnay Heat Recovery Ventilation System removes stale, dirty air and draws
in fresh air from outside. Lossnay also recovers heat energy from the air being transferred to pre-warm
(or pre-cool) the fresh air being drawn into your home. The VL220 model is ideal for small to medium
sized homes between 52m2 and 192m2.
1. The stale air extracted from your home is Return Air (RA). Return
Air can contain high levels of CO2, odours and other pollutants.
This Return Air stream also contains heat energy that Lossnay
can recover, which is not the case with other positive pressure
ventilation systems.
2. As the stale Return Air is removed, Lossnay’s core ‘recovers’ the
useful heat energy from it. The air is then exhausted (EA) outside
along with the unwanted pollutants.
3. Outdoor Air (OA) is introduced to provide fresh clean air. It is first
filtered, then passed through the Lossnay core. This allows it be
pre-heated in winter (or pre-cooled in summer) using the energy
recovered from the Return Air.
4. Supply Air (SA) then enters your house as fresh pre-heated or
pre-cooled air.
EXTRACTS STALE AIR
Extracts stale air removing toxins and reducing
humidity.
SUPPLIES FRESH AIR
Supplies fresh air increasing the oxygen levels in
the home and assists with managing the build
up of moisture.
HEAT ENERGY RECOVERY
Recovers up to 86% of the heat energy from the
outgoing air to preheat the incoming air, saving
you money.
THE DIAMOND LOSSNAY CORE
How Fresh Air Heat Energy Recovery Works
EA
Outdoors
St
al
e
Stale dirty indoor air
(Exhausted Air)
Indoors
Fr e s
SA
h
Fresh air into home
(Supply Air)
Partition plate
Spacer plate
e
h
al
Fresh air introduction
(Outdoor Air)
Fr e s
St
OA
RA
Stale air removed from home
(Return Air)
Balanced Pressure Heat Recovery Ventilation Benefits
Ventilating your home is vital as it maintains air quality and reduces moisture, creating a healthier and
more comfortable environment. The Mitsubishi Electric Lossnay System is a patented heat recovery
ventilation solution that uses fresh air (not attic air) to ventilate your home. The system works by
extracting stale air from inside your house and replacing it with allergen reduced fresh air from outside.
Improved Air Quality
Creates a Healthier Home
By drawing in fresh outdoor air, indoor air
Filtered fresh air improves air quality for allergy
quality is improved as high levels of CO2,
and asthma sufferers.
odours and other pollutants are removed from
your home.
Fresh Air Without Open Windows
Energy Efficient
Lossnay allows you to have a well-ventilated
Incoming fresh air is pre-warmed so your
home without the need to open windows. This
heating system isn’t required to work as hard to
improves the safety of your home and family
reach desired temperature. This is highly energy
and means outdoor noise is minimised.
efficient, and can help reduce heating bills.
Retains Heat
Lossnay’s unique Heat Recovery Technology
Assists Moisture and
Condensation Control
collects up to 86% of the heat energy in
Lossnay effectively reduces moisture in your
outgoing air which is then used to pre-warm or
home by directly removing stale air that causes
cool the fresh air vented in.
condensation via the Lossnay core.
Balanced Pressure, No Draughts
Easy Control At Your Finger Tips
Lossnay is specifically designed for more
An intuitive wall controller with easy to read
airtight homes built to the current New Zealand
LCD display comes standard. Fan speed, night
building code, bringing in the optimum amount
set back and 24-hour and weekly timers can
of fresh air without creating draughts and
easily be customised and programmed with up
minimising indoor temperature fluctuations.
to 8 stop and start patterns per day.
Quietest in its Class
Easy To Clean
At an ultra quiet 14dBA in low fan speed,
The standard filters can be removed for
the Lossnay VL220 is the quietest system in
regular cleaning to keep the unit in optimal
its class.
working condition.
Positive Pressure roof cavity ventilation
VS
Balanced Pressure Fresh Air Heat Recovery Ventilation
These systems typically force air into the
Balanced ventilation mechanically removes
home from the attic space and specifically
stale air and replaces it with clean, fresh air
require gaps in the building structure
at the same rate. It is also fitted with a heat
(common in older homes) to facilitate air
exchanger that actively recovers heat energy
displacement. As these systems are not
from the outgoing stale indoor air to pre-warm
designed to recover heat energy to help
incoming fresh air. As such, the need for
pre-warm incoming air, colder incoming air
will require more additional heating – adding
to your power bill.
additional heating of fresh air is reduced. This
Air goes in and gets trapped
system is specifically designed for modern
homes that are of more airtight construction.
Fresh air goes in while
stale air is pushed out
Lossnay VL220 Technical Specifications
Dimensions
174 119
33
EA
(Exhaust air)
Duct connecting
flange (EA)
234
31
320
362
98
124
146
Duct connecting
flange (OA)
199
775(Ceiling suspension fixture)
815
Exhaust air filter case
Auxiliary fixture
Lossnay - Residential
Model
Drain pan
VL-220CZGV-E
Ventilation modes
Lossnay Sizing Guide VL-220CZGV-E
Air to Air sensible heat exchanger
Heat exchange element material
Specially treated non permeable resin core
Operating range
OA temperature -5°C* to +40°C, 80%RH
Weight (kg)
31
Electrical power supply
220-240 V / 50Hz
Fan speed
220V / 60 Hz
Fan Speed 4 Fan Speed 3 Fan Speed 2 Fan Speed 1
Input power (W)
80
35
18.5
8.5
230
165
120
65
64
46
33
18
164
84
44
13
Temperature exchange efficiency (%)
82
84
85
86
Noise (dB) (Measured at 1.5m under the
centre of an anechoic chamber)
31
25
19
14
(m /h)
3
(L/s)
External static pressure (Pa)
Duct size
(Unit mm)
Supply air filter case
Bypass†
Heat recovery mode
Heat exchange system
Air volume
OA
(Outdoor air)
20
720
151
Type
8
80
8
RA1
(Return air)
Duct connecting
flange (RA1)
295
271
885
229
SA
(Supply air)
850
Duct connecting
flange (SA)
139
86
Drain outlet
116
Ceiling suspension fixture
31
Power supply cable opening
143
848(Ceiling suspension fixture)
Sample Installation
150mm
House Size m² Ceilingm²Height
25
2.4
50
2.4
75
2.4
100
2.4
125
2.4
150
2.4
175
2.4
190
2.4
House Air
Volume m³
60
120
180
240
300
360
420
456
NZ 4303
m³/hr
21
42
63
84
105
126
147
160
BS Standard
m³/hr
30
60
90
120
150
180
210
228
Fan Speed
House Size m² Ceiling Height
m²
25
2.7
50
2.7
75
2.7
100
2.7
125
2.7
150
2.7
175
2.7
House Air
Volume m³
68
135
203
270
338
405
473
NZ 4303
m³/hr
24
47
71
95
118
142
166
BS Standard
m³/hr
34
68
102
135
169
203
237
Fan Speed
1
1
2
2
3
4
4
4
1
2
2
3
4
4
4
House sizing guide is based on British Standard for ventilation requiring 0.5 Air changes per
hour. New Zealand standard (NZ4303) is 0.35 air changes per hour
*Return Air will continue to operate from -5°C to -15°C.
Optional VL220 Extras
Filters
Exhaust fans
The VL220 Ventilation system is supplied with 2 standard (G3)
Mitsubishi Electric offer a range of energy efficient exhaust
replacement filters that can be washed up to 4 times.
fans that feature low vibration and quiet operation – ideal for
The 2 exhaust Filters can be upgraded to non-washable medium
the extraction of moisture and contaminants in bathrooms and
efficiency filters (G4).
kitchens. These exhaust fans are designed to specifically work
The 2 supply filters can be upgraded to non-washable high
in harmony with the Lossnay VL220 system.
efficiency filters (M6).
†
Bypass Damper
When the outdoor temperature is cooler than the indoor
5 Year Warranty
temperature (and vice versa) the optional damper allows a
The Mitsubishi Electric Lossnay product in this brochure comes with
bypass of the heat exchanger should temperature conditions
a full 5 year parts and labour warranty. Warranty conditions apply.
reach set levels.
www.mitsubishi-electric.co.nz
WELLINGTON
AUCKLAND
CHRISTCHURCH
HEAD OFFICE
BRANCH
BRANCH
1 Parliament Street
Unit 1, 4 Walls Road
44 Halwyn Drive
PO Box 30772
PO Box 12726
PO Box 16904
Lower Hutt 5040
Penrose, Auckland 1642
Hornby, Christchurch 8441
Phone (04) 560 9147
Phone (09) 526 9347
Phone (03) 341 2837
Fax (04) 560 9133
Fax (09) 526 9369
Fax (03) 341 2838
All features and specifications are subject to change and amendment at anytime. May 2016.