COVER + INDEX _ Layout
Transcription
COVER + INDEX _ Layout
B U IL D ING C O N S E N T IS S UE da t e : 14 Nov 20 13 architectural drawing index cover set COVER + INDEX plans set A1.0 SITE & SLAB PLAN A1.1 GROUND & FIRST FLOOR PLAN A1.2 SECOND FLOOR & ROOF PLAN A1.3 REFLECTED CEILING PLANS A2.1 ELEVATIONS A3.1 SECTIONS A & B A3.2 SECTION C A3.3 SECTIONS D & E A4.1 DETAILS A4.2 DETAILS A4.3 DETAILS elevations set sections set details set interior elevation set A5.1 INTERIORS - BATHROOM A7.1 DOOR & WINDOW SCHEDULE A7.2 DOOR & WINDOW SCHEDULE schedules N E W O F F IC E B U IL D IN G 307 D UR HA M ST R EET f ile: 4643 sit e inf or mat ion property address: 307 DURHAM STREET, CHRISTCHURCH legal description: LOT 1, DP 9537 property area: sit e/ loc at ion k ey EXPOSED AGGREGATE 50mm MESH REINFORCED PAVING 491m² ASPHALTIC CONCRETE (HOTMIX) DRIVE AS SPECIFIED WITH 100x35 H5 TREATED TIMBER EDGE OR CONCRETE KERB NEW BUILDING FOOTPRINT 0. 00 EXISTING SITE LEVELS, AS PER SURVEYORS DOCUMENTATION 0.00 PROPOSED SITE LEVEL, FINISHED HEIGHT 0.00 FFL PROPOSED SLAB LEVEL, FINISHED HEIGHT SITE FENCE 1 2 21,400 N 2,160 BUILDING SET OFF 75mm AT CLOSEST POINT 2,500 EXISTING MAGNOLIA TREE TO REMAIN, LOCATION TO BE CONFIRMED ONSITE 3,990 rail 1 rail 2 1.58 m2 DP1 1. REFER STRUCTURAL ENGINEER FOR GEOTECH REPORT 2. REFER ENGINEERS DOCUMENTATION FOR SITE SURVEY 3. TREES SHOWN SHALL REMAIN AND BE PROTECTED AS NECESSARY visitor cycle stand (2no. min) 4. STOCKPILE TOPSOIL AS DIRECTED ON SITE 5. REFER LANDSCAPE ARCHITECT FOR PLANTING, SOFT LANDSCAPING AND ANCILLARY PAVING 6. REFER DRAINAGE/HYRAULIC ENGINEERS DOCUMENTS FOR ALL STORMWATER AND SEWER DRAINAGE 7. REFER SITEWORK SPECIFICATION rail 3 H5 TREATED 200x200 TIMBER KERB AS TREE SURROUND FALL FALL 1 BUC ASPHALT TO CARPARK FALLS TO SUMP EXPOSED AGGREGATE TO FALLS UP TO ENTRANCE DOOR THRESHOLD DC rail 5 FALL 2 SUMP FINAL LOCATION DETERMINED BY DRAINAGE ENGINEER existing vehicle crossing g a r d e n b e d 3 12,370 BOUNDARY L FAL s t r e e t 5,000 FAL L 12,080 BOUNDARY sit e/ loc at ion plan not es GALVANISED 3.5m LONG x 400mm HIGH BOUNDARY RAIL FROM 100mm PFC FOR PAINT FINISH staff covered cycle stand (5no. min) 8,790 2,850 22,695 BOUNDARY n e w b uilding 14.04 m2 PRECAST CONCRETE COLUMN 1,800 3,050 FALL DC 150 A FALL EXPOSED AGGREGATE PATH EX. SEWER DRAIN 252.64 m2 LIFT SUMP HT FALL B EDGE OF EXPOSED AGGREGATE PAVING 150mm OFF BOUNDARY HOSE TAP, REFER HYDRAULIC/DRAINAGE ENGINEER DOCUMENTATION HT 2,500 CL DP4 EXPOSED AGGREGATE PATH BUBBLE-UP CHAMBER, REFER HYDRAULIC/DRAINAGE ENGINEER DOCUMENTATION d u r h a m 75 C BUC 13,850 3,600 120/120/120 FFR WALLS TO BOTH NORTH & SOUTH BOUNDARIES BACK FLOW PREVENTER, REFER HYDRAULIC/DRAINAGE ENGINEER DOCUMENTATION rail 4 3,100 3 BFP DP2 DP3 g a r d e n b e d 6.73 m2 40,510 BOUNDARY BFP SITE AREA: 490.28 m2 CRITICAL SET-OUT NOTE BUILDING TO BE PARALLEL AND OFF-SET 75mm FROM THE SOUTH BOUNDARY pr opos e d site pla n SCALE: 1:100 3,500 APPROX. (C.O.S.) b o u n d a r y r ail s c h e d u l e 200 PRELIMINARY PRINT | 14/11/13 | 3:45 PM 400 400 CHECK LEVELS ON SITE PRIOR TO FABRICATION 600 MITRE AND WELD RAIL AND LEGS 150 100mm ZINC SPRAYED PFC RAIL AND LEGS 400x400x600 CONCRETE FOOTING 400 - b o u n d a r y r ail d e t a i l - SCALE 1:50 400x700x600 CONCRETE FOOTING 700 NO. RAIL 1, RAIL 2, RAIL 3, RAIL 4, RAIL 5 LOCATION SITE CARPARK CONSTRUCTION 100mm PFC RAIL AND LEGS SET IN CONCRETE FOOTING FINISH ZINC SPRAYED HARDWARE LATCH & LOCKSET, LEVER HANDLE, DOOR CLOSER, RAVEN THRESHOLD BAR FOR LEVEL THRESHOLD NOTES RAILS 1-3 INSTALLED WITH TOES FACING CARPARK, RAILS 4-5 INSTALLED WITH TOES FACING STREET (5 OFF) A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T SITE & SLAB PLAN 13/11/13 TH 15/03/2013 SL 1:100, 1:50@A2 1:200@A4 4643 BUILDING CONSENT ISSUE A1.0 A 1 21,400 8,960 75 1,950 90 1,550 1,850 90 3,500 90 90 4,880 95 70 20 9,005 900 580 20 3,400 4,880 20 4,385 400 CL 200 s t r e e t existing vehicle crossing 3,500 90x45 H3.2 TREATED MSG8 TIMBER FRAMED WALL 1,960 140x45 H3.2 TREATED MSG8 TIMBER FRAMED WALL FIRE RATED WALL, REFER FIRE ENGINEERS REPORT. FIRE RATED CONSTRUCTION TO EXTEND TO SOFFIT OR UNDERSIDE OF ROOF CLADDING, NOTCH AROUND ROOF FRAMING AND SEAL ALL AROUND WITH INTUMESCENT SEALANT W1.3 45 OVERHEAD EAVE LINE SHS POST EXTERNAL METAL CLAD SILL DOOR REFERENCE BY NUMBER, REFER DRAWING SERIES A7, WHERE; DG. - GROUND FLOOR DOOR D1. - FIRST FLOOR DOOR D2. - SECOND FLOOR DOOR D2.# FFL 18,860 1,950 90 1,550 45 200 1,775 200 25 4,900 O F F I C E D U R H A M 4,900 B A3.1 B U I L D I N G S T R E E T 11,840 9,840 W1.1 5,735 90 4,900 SELECTED VINYL FLOOR FINISH EM SELECTED ENTRANCE MAT FLOOR FINISH CT SELECTED CARPET TILE FLOOR FINISH 200 DP2 FLOOR FINISHES ONLY WHERE INDICATED V C A3.2 45 2,590 800 x 400 PRECAST BUTTRESS 200 30 31 32 33 16 34 17 17 18 D1.4 200 19 CT 1. 800 810 810 wc lo b b y D1.5 200 TEA SINK 2,075 950 200 lo b b y lif t OVERFLOW SCUPPER OUTLETS f loor f inishes k ey 9 A4.2 90 90 90 1,650 90 2,690 45 45 200 200 29 28 27 90 SCALE: 1:100 3 0 7 26 V pr opos e d first f loor pla n N E W 25 4,475 24 5,305 23 140 wc DP3 710 r aised plat f or m CT 810 JOINERY UNIT REFERENCE BY NUMBER, REFER DRAWING SERIES A6 J# OFS CT acc wc W2.# SMOKE DOOR FRR DOOR D1.1 22 C A3.2 V E A3.3 W1.# DOUBLE INSOL SOLARIS FINS 21 1 A4.3 D1.3 E A3.3 810 W1.8 W1.7 REFER INTERIOR ELEVATIONS SHEET A5.1 FOR WC AND KITCHENETTE DETAILS CONCRETE FILLED STRUCTURAL 200 SHS POST WITH 2x19mm FYRELINE WALL LININGS AS FIRE PROTECTION TO ACHIEVE 120min FIRE RATING W1.2 B A3.1 WINDOW REFERENCE BY NUMBER, REFER DRAWING SERIES A7, WHERE; DG. - GROUND FLOOR WINDOW D1. - FIRST FLOOR WINDOW D2. - SECOND FLOOR WINDOW WG.# BEAM OVER CONCRETE FILLED STRUCTURAL 200 SHS POST WITH INTUMESCENT PAINT FIRE PROTECTION TO ACHIEVE 120min FIRE RATING t e na nc y 2 LINE OF STRUCTURE OVER d u r h a m rail 5 12,370 BOUNDARY 1,500 2,000 1,600 2,590 45x70 H3.2 TIMBER STRAPPING D1.# D A3.3 505 90 800 x 400 PRECAST BUTTRESS 10 A4.3 20 4,260 STRUCTURAL PRECAST CONCRETE PANEL, REFER STRUCTURAL ENGINEERS DOCUMENTATION DP1 GFA: 279 m2 SHS POST 200 90 DG.# CONCRETE FILLED STRUCTURAL 100 SHS POST WITH INTUMESCENT PAINT FIRE PROTECTION TO ACHIEVE 120min FIRE RATING D A3.3 2,075 8 A4.3 f loor plan k ey 2,160 FRR WINDOW 2,400 W1.5 SHS POST W1.6 2,400 SUNSHADE LOUVRES OVER 4,950 11,840 6,260 2,630 200 175 8,790 2 A4.3 SITE AREA: 490 m2 3 13,885 2400 x 400 SHEARWALL similar 400 2 A A3.1 300 DP4 355 1,960 45 BFP A A3.1 W1.4 1 A4.3 90 b e d 3,500 90 STORE (UNDER STAIR) 21,400 4,475 4,050 9,580 B A3.1 3,100 6 A4.1 90 90 200 200 1,775 25 g a r d e n 200 90 45 C A3.2 800 5,280 350 Ø PRECAST CONC COLUMN 200 40,510 BOUNDARY CRITICAL SET-OUT NOTE DP2 910 1 2 LIFT SUMP up p e r f loor s t e na nc y ent r anc e SUMP 2000 x 400 PRECAST PANEL 45 90 1,110 1,390 ent r y st or e ( unde r ) 3 wc lo b b y DC SHS POST 4 lif t 650 FRR DOOR D0.1 650 lo b b y 5 V 810 7 D0.6 wc DP3 710 EM D0.4 CT 1 3,050 910 810 CT acc wc D0.7 TEA SINK V BUC 200 4 A4.1 gr o und f loor t e na nc y ent r anc e D0.5 SCALE: 1:100 75 rail 3 E A3.3 DC SMOKE CURTAIN TO LIFT DOORS (TYPICAL) pr opos e d gr o und f loor pla n PRELIMINARY PRINT | 14/11/13 | 3:45 PM E A3.3 45 D0.3 REFER INTERIOR ELEVATIONS SHEET A5.1 FOR WC AND KITCHENETTE DETAILS LINE OF STRUCTURE OVER C A3.2 200 CONCRETE FILLED STRUCTURAL 200 SHS POST WITH INTUMESCENT PAINT FIRE PROTECTION TO ACHIEVE 120min FIRE RATING 90 A rail 2 5 A4.1 B A3.1 D A3.3 140 25 BUILDING TO BE PARALLEL AND OFF-SET 75mm FROM THE SOUTH BOUNDARY B rail 1 rail 4 GFA: 252 m2 D0.2 W0.3 t e na nc y 1 HT C 22,695 BOUNDARY 7,040 FFL 15,560 8,670 2 A4.1 CONCRETE FILLED STRUCTURAL 100 SHS POST WITH INTUMESCENT PAINT FIRE PROTECTION TO ACHIEVE 120min FIRE RATING 810 2,850 1 A4.1 SHS POST SHS POST 2,500 800 x 400 PRECAST BUTTRESS 10 A4.3 200 W0.2 SUNSHADE LOUVRES OVER 1.8m HIGH TIMBER FENCE b e d g a r d e n 12,080 BOUNDARY 505 200 3,250 2,075 3,050 DP1 2 A4.3 6 A4.3 7 A4.3 2,500 400 1,960 FRR WINDOW 8 A4.3 3,600 CL 6 200 2,630 2,410 6,250 5,960 8,790 11,840 DP4 1,800 A 45 2,400 W0.1 3,990 2400 x 400 SHEARWALL 13,850 4,385 11,435 similar D A3.3 2,160 4,900 BUILDING SET OFF 75mm AT CLOSEST POINT C 1 A4.3 600 300 45 45 120/120/120 FFR WALLS TO BOTH NORTH & SOUTH BOUNDARIES B 900 200 45 300 25 3,400 200 4,900 800 4,475 N CONC BEAM OVER 3,100 3 45 3,100 2 A A3.1 6,160 90 4,385 0 1 2 3 4 5 90 A A3.1 A GROUND & FIRST FLOOR PLAN 13/11/13 TH 15/03/2013 SL 1:100@A2 1:200@A4 4643 BUILDING CONSENT ISSUE A1.1 A 4,475 1,670 1 A4.2 4,880 20 3,980 4,880 20 5,800 f loor plan k ey 2,160 4,880 900 580 20 3,400 4,880 20 4,385 20 4,385 5,950 STRUCTURAL PRECAST CONCRETE PANEL, REFER STRUCTURAL ENGINEERS DOCUMENTATION 5,800 45x70 H3.2 TIMBER STRAPPING 360 SKYLIGHT OVER REFER INTERIOR ELEVATIONS SHEET A5.1 FOR WC AND KITCHENETTE DETAILS 1,950 20 90 20 4,880 20 3,100 W2.3 20 4,385 9,840 800 320 2 A A3.1 BUTYL ON TREATED PLY ON FRAMING AT 400mm CRS 3 2,160 SKY3 SKY5 COLORSTEEL CAPPING TO TIMBER FRAMED PARAPET WALL RIDGE E A3.3 size (mm) material DP 1 80 DP 2 80 80 DP 3 DP 4 DP 5 80 80 80 65 POWDER COATED GALVANISED STEEL CHS WHERE EXPOSED AT GROUND FLOOR uPVC WHERE CONCEALED POWDER COATED GALVANISED STEEL CHS WHERE EXPOSED AT GROUND FLOOR uPVC WHERE CONCEALED uPVC uPVC COLORSTEEL E A3.3 15 DEG SKY4 ref no. 4 A4.2 SKY2 B A3.1 do w np ip e s c hedule 0.55 COLORSTEEL PROFILED METAL ROOF BARGE 1200 x 600 DOUBLE GLAZED LOW PITCHED FIXED SKYLIGHTS (x8) ON TIMBER KERBS WITH FOLDED COLORSTEEL APRON FLASHINGS AND CRICKET DIVERTERS TO TOP EDGE. OVERFLOW SCUPPER, TYPICAL AS SPECIFIED PARAPET OFS SUPPLY FAN 7 A4.2 1:60 FALL 200 75 600 DP3 1:60 FALL 1:30 FALL 1:60 FALL DP5 PARAPET RAKING END TO SIDE PRECAST WALL pr opos e d r oof pla n SCALE: 1:100 O F F I C E 3 0 7 DP2 C A3.2 OFS 0 PARAPET BUTYL ROOF ON TREATED PLY ON FRAMING @ 400 CRS N E W PARAPET r oof 2 SKY1 C A3.2 PASSIVE VENTILATOR SPOUTING PARAPET 3,050 15 DEG EXTRACT FAN OFS PRELIMINARY PRINT | 14/11/13 | 3:45 PM 15 DEG BARGE B DP1 1:60 FALL 15 DEG SUNSHADE LOUVRES BELOW A 1:30 FALL D A3.3 BARGE D A3.3 2 DEG 11,440 BALCONY BELOW DOMED RAINWATER OUTLET, TYPICAL AS SPECIFIED BARGE 2 DEG r oof 3 8,790 BUTYL ROOF ON TREATED PLY ON FRAMING @ 400 CRS SKYLIGHT REFERENCE BY NUMBER, REFER SPECIFICATION SKY# PARAPET r oof 1 4/5 A4.2 SELECTED CARPET TILE FLOOR FINISH r oof plan k ey 2,160 7 A4.1 2 A4.2 CT 90 GUTTER HIGH POINT PARAPET COLORSTEEL PARAPET CAPPING SELECTED ENTRANCE MAT FLOOR FINISH 90 15 DEG 200 175 RAKING END TO SIDE PRECAST WALL EM FORM SUMP SET DOWN AS E2 AS1 BUTYL ON TREATED PLY ON FRAMING AT 400 CRS DP4 SELECTED VINYL FLOOR FINISH V 200 DP2 FLOOR FINISHES ONLY WHERE INDICATED 0.55 COLORSTEEL ENDURA V-RIB ROOFING WITH MATCHING FLASHINGS AS SPECIFIED 18,500 1:60 FALL OFS f loor f inishes k ey A A3.1 21,400 1,070 90 OVERFLOW SCUPPER OUTLETS 1. FORM SUMP SET DOWN AS E2 AS1 C JOINERY UNIT REFERENCE BY NUMBER, REFER DRAWING SERIES A6 OFS W2.1 140 2,590 380 PFC BEAM 140 4,880 1 PARAPET W2.# C A3.2 11,525 B A3.1 SCALE: 1:100 140 45 30 31 32 33 34 35 36 37 38 CT 90 200 200 1,305 200 1,775 25 4,880 W1.# 9 A4.2 200 90 pr opos e d s e c o nd f loor pla n 1,600 140 2,635 SKYLIGHT OVER 810 D2.4 D2.5 200 2,075 lo b b y 200 200 200 3,050 2,075 200 200 3,050 75 wc lo b b y V 29 3,910 4,455 lif t 28 140 1,600 wc DP3 710 27 8 A4.1 CT CT 810 DOUBLE INSOL SOLARIS FINS FRR DOOR D2.2 26 C A3.2 V acc wc E A3.3 WINDOW REFERENCE BY NUMBER, REFER DRAWING SERIES A7, WHERE; DG. - GROUND FLOOR WINDOW D1. - FIRST FLOOR WINDOW D2. - SECOND FLOOR WINDOW WG.# SHS POST 25 2 A4.3 D2.# 140 FRAMING 24 similar DOOR REFERENCE BY NUMBER, REFER DRAWING SERIES A7, WHERE; DG. - GROUND FLOOR DOOR D1. - FIRST FLOOR DOOR D2. - SECOND FLOOR DOOR J# D2.3 SHS POST B OVERHEAD EAVE LINE D1.# E A3.3 810 810 B A3.1 D A3.3 FIRE RATED WALL, REFER FIRE ENGINEERS REPORT. FIRE RATED CONSTRUCTION TO EXTEND TO SOFFIT OR UNDERSIDE OF ROOF CLADDING, NOTCH AROUND ROOF FRAMING AND SEAL ALL AROUND WITH INTUMESCENT SEALANT EXTERNAL COLORSTEEL ON PLY SILL W2.2 GFA: 280 m2 3 A4.2 140x45 H3.2 TREATED MSG8 TIMBER FRAMED WALL DG.# 360 UB PORTAL t e na nc y 3 SHS POST CONC NIB UPSTAND AT DOOR THRESHOLD 360 UB PORTAL FFL 22,160 2 A4.3 9 A4.1 SHS POST SKYLIGHT OVER 360 UB PORTAL 200 UB + 250 PFC BEAM SHS POST 90x45 H3.2 TREATED MSG8 TIMBER FRAMED WALL 10 A4.3 360 UB PORTAL W2.5 5 A4.3 D2.1 9,165 5,960 11,840 8,790 CONCRETE FILLED STRUCTURAL 100 SHS POST WITH INTUMESCENT PAINT FIRE PROTECTION TO ACHIEVE 120min FIRE RATING LIQUID APPLIED MEMBRANE TO BALCONY AT 2º PITCH. 8 A4.3 similar W2.6 b a lc o ny SUNSHADE LOUVRES OVER CONTINUOUS VERTICAL SAWCUT AT FLASHING JUNCTION WITH PRECAST CONCRETE PANEL D A3.3 DP1 380 PFC BEAM FRR WINDOW NOTE - EXTENT OF PANEL REDUCED BY 90mm TO ALLOW FRAMING TO EXTEND 140 FRAMING 45 2,690 90 45 200 950 90 1,650 90 200 200 2,430 DP4 8 A4.1 CANTILEVER POST AND GLASS BALUSTRADE WITH SQUARE TOP HANDRAIL AS SPECIFIED. A 20 W2.4 175 C 4,880 11,840 20 3 200 21,400 4,455 2 A A3.1 800 1 D U R H A M similar 7 A4.1 800 x 600 DOUBLE GLAZED LOW PITCHED FIXED SKYLIGHTS (x2) ON TIMBER KERBS WITH FOLDED COLORSTEEL APRON FLASHINGS AND CRICKET DIVERTERS TO TOP. B A3.1 B U I L D I N G S T R E E T 1 2 3 4 5 BUTYL ON TREATED PLY ON FRAMING AT 400 CRS A A3.1 A SECOND FLOOR & ROOF PLAN 13/11/13 TH 15/03/2013 SL 1:100@A2 1:200@A4 4643 BUILDING CONSENT ISSUE A1.2 A 1 2 3,100 21,400 3 1 2 2,160 21,400 3 2,160 CL DP1 DP4 RJW 1no. LAYER 19mm GIB FYRELINE OVER 45x70 TREATED TIMBER STRAPING ON PRECAST CONCRETE PANEL 1no. LAYER 19mm GIB FYRELINE OVER 45x70 TREATED TIMBER STRAPING ON PRECAST CONCRETE PANEL RJC RJC DP4 RJC RJC DP1 RJW 2420 RJC CONTINUES AROUND COLUMNS, TYPICAL 6mm HARDIFLEX SOFFIT LINING 6mm HARDIFLEX SOFFIT LINING HF SUN SHADING LOUVRES OVER acc wc GIB1 DP3 1no. LAYER 13mm GIB AQUALINE TO KITCHEN SINK WALL ONLY 2420 2420 wc 1.82 m2 RJC RJW 4.64 m2 VOID OVER 2420 lif t wc lo b b y lo b b y GIB1 2420 RJC EQ HF RJC SKY LIGHT EQ RJC RJC RJW 1no. LAYER 13mm STANDARD GIB OVER 70x70 TREATED TIMBER STRAPING ON PRECAST CONCRETE PANEL RAKING GIB1 RJC GIB1 3.94 m2 3.22 m2 RJW DP2 RJC acc wc GIB1 DP3 3.94 m2 3.22 m2 GIB1 2420 2420 wc 1.82 m2 2420 wc lo b b y RJC RJW 3900 lif t lo b b y 2420 RJC 1no. LAYER 13mm GIB AQUALINE TO WASH HAND BASIN WALL ONLY 478 2,400 EQ 14.35 m2 PLY1 PLYWOOD RAKING 1no. LAYER 13mm GIB FYRELINE TO EACH SIDE OF 60/60/60 FRR TIMBER FRAMED FIRE WALL, AS PER GBTL 60 GIB SYSTEM RJC RJW NOTE 8 RAKING APPROX 140mm WIDE GIB LINED BULKHEAD AT CHANGE IN CEILINGS 2320 SKY LIGHT NOTE 8 GIB1 2420 1no. LAYER 13mm GIB FYRELINE TO EACH SIDE OF 60/60/60 FRR TIMBER FRAMED FIRE WALL, AS PER GBTL 60 GIB SYSTEM 2.69 m2 14.70 m2 RAKING 2700 GIB2 193.23 m2 RJC TILE GRID t e na nc y 3 SKY LIGHT FIRE RATED STRUCTURAL STEEL POSTS LINED IN 2no. LAYERS 19mm GIB FYRELINE WALL LINING INSTALLED TO COMPLY WITH GIB FIRE RATED PROTECTION OF STEEL COLUMN WITH STEEL CLIP AND CHANNEL SYSTEM TYPICAL 222.54 m2 1no. LAYER 13mm STANDARD GIB OVER 70x70 TREATED TIMBER STRAPING ON PRECAST CONCRETE PANEL b a lc o ny t e na nc y 2 2no. LAYERS 19mm GIB FYRELINE ONE SIDE OF 120/120/120 FRR TIMBER FRAMED FIRE WALL, AS PER GBTL 120 GIB SYSTEM 2no. LAYERS 19mm GIB FYRELINE ONE SIDE OF 120/120/120 FRR TIMBER FRAMED FIRE WALL, AS PER GBTL 120 GIB SYSTEM RJC HF RAKING SUN LOUVRE OVER RAKING GIB MOVEMENT JOINTS TYPICALLY ALIGN WITH PORTAL FRAMES OVER. 1,200 RJW DP2 1,200 PERFORATED VENEERED BLONDED DECORTECH FIRE SAFE PLY pr opos e d first f loor rpla cpn pr opos e d s e c o nd f loor pla r c pn SCALE: 1:100 SCALE: 1:100 1 2 3,100 21,400 3 int er nal linings 2,160 BUILDING SET OFF 75mm AT CLOSEST POINT CL 75 120/120/120 FFR WALLS TO BOTH NORTH & SOUTH BOUNDARIES RESILIENT VERTICAL CONTROL JOINT WHERE GIB SUBSTRATE CHANGES FROM TIMBER FRAMING TO CONCRETE INTERNAL LININGS INTERNAL WALL LININGS SHALL BE AS FOLLOWS: CEILINGS INTERNAL CEILING LININGS SHALL BE AS FOLLOWS: 1. GENERALLY EXCEPT WHERE INDICATED OTHERWISE – 13mm STANDARD GIB. 1. 2. FIRE RATED INTERNAL PARTITIONS BETWEEN STAIR LOBBY AREAS AND TENANCIES – 13mm GIB FYRELINE EACH SIDE. DP1 DP4 2no. LAYERS 19mm GIB FYRELINE OVER 45x70 TREATED TIMBER STRAPING ON PRECAST CONCRETE PANEL CUT OUT FOR RECESSED LIGHT FITTING - REFER TO ELECTRICAL ENGINEERS DOCUMENTATION. 3. INTERNAL LININGS OF FIRE RATED EXTERNAL TIMBER FRAMED WALL – 2no. LAYERS 19mm GIB FYRELINE. 4. TOILETS/ACCESSIBLE TOILETS THROUGHOUT – 13mm GIB AQUALINE TO WHB WALL, 13mm STANDARD GIB ELSEWHERE ALL FOR SEMI GLOSS ENAMEL PAINT FINISH. SUN SHADING LOUVRES OVER 5. t e na nc y 1 2no. LAYERS 19mm GIB FYRELINE ONE SIDE OF 120/120/120 FRR TIMBER FRAMED FIRE WALL, AS PER GBTL 120 GIB SYSTEM FIRE RATED STRUCTURAL STEEL POSTS LINED IN 2no. LAYERS 19mm GIB FYRELINE WALL LINING INSTALLED TO COMPLY WITH GIB FIRE RATED PROTECTION OF STEEL COLUMN WITH STEEL CLIP AND CHANNEL SYSTEM TYPICAL 1no. LAYER 13mm GIB FYRELINE TO EACH SIDE OF 60/60/60 FRR TIMBER FRAMED FIRE WALL, AS PER GBTL 60 GIB SYSTEM 194.17 m2 TILE GRID 2700 1no. LAYER 13mm STANDARD GIB OVER 70x70 TREATED TIMBER STRAPING ON PRECAST CONCRETE PANEL HF 6mm HARDIFLEX ON TIMBER SOFFIT FRAMING NOTE 8 GIB EXPOSED TO VIEW SHALL BE LEVEL 4 FOR SATIN PAINT FINISH. GIB EXTENDING ABOVE CEILING LEVEL AS PART OF FIRE RATED PARTITION TO SECOND FLOOR STAIR LOBBY SHALL BE LEVEL 3 FINISH. 6. ALLOW FOR RAKING PLANTED STAIR STRINGER CUT TO STAIR PROFILE TO OUTSIDE OF ALL STAIR FLIGHTS. 7. ALLOW FOR 60 x 12mm PAINTED TIMBER SKIRTING THROUGHOUT. 8. ALLOW FOR 3 no. RONDO PANTHER WALL ACCESS HATCHES IN LOCATIONS TO SUIT HYDRAULIC ENGINEER. RJW GIB1 DP3 CRITICAL SET-OUT NOTE PRELIMINARY PRINT | 14/11/13 | 3:45 PM BUILDING TO BE PARALLEL AND OFF-SET 75mm FROM THE SOUTH BOUNDARY 1no. LAYER 13mm GIB AQUALINE TO KITCHEN SINK WALL ONLY 2420 2420 wc 1.82 m2 GIB1 2420 wc lo b b y RJC RJW GIB1 VOID OVER lif t 3.75 m2 RJC VOID OVER GIB1 2700 lo b b y RJC 4.65 m2 6.22 m2 2700 RAKING st or e RAW CONC ( unde r ) TO UNDERSIDE OF STAIR 4.29 m2 SLOPING WITH STAIR ABOVE RJC acc wc 3.22 m2 RJC GIB1 3.94 m2 c eiling plan not es 2. 3. 4. c eiling plan k ey 1200x600 SELECTED CEILING TILE & GRID SYSTEM STAIR ENCLOSURE AND LOBBIES GENERALLY – 13mm STANDARD GIB FOR PAINT FINISH ON RONDO SUSPENSION SYSTEM EXCEPT TO SECOND FLOOR – REFER BELOW. SECOND FLOOR ENCLOSURE AND LOBBY – SELECTED VENEERED 12mm DECORTECH FIRESAFE PLY ON RONDO SUSPENSION SYSTEM. FAIRFACED CONCRETE - PAINT FINISH 13mm STANDARD GIB PLASTERBOARD CEILING ON RONDO SUSPENSION SYSTEM. WHERE; GIB1 - INDICATES LEVEL CEILING GIB2 - INDICATES RAKING CEILING GIB 1 GIB 2 TOILETS/ACCESSIBLE TOILETS THROUGHOUT –13mm STANDARD GIB SEMI-GLOSS ENAMEL PAINT FINISH. SECOND FLOOR RAKING AND FLAT CEILING – 13mm GIB ON RONDO SUSPENSION SYSTEM. ALLOW FOR GIB MOVEMENT JOINTS AS SHOWN. ALLOW FOR SHADOW LINE BEAD AT JUNCTION OF WALLS AND CEILING THROUGHOUT SECOND FLOOR. 5. UNDER STAIR CUPBOARD – 13mm STANDARD GIB ON STEEL BATTENS. 6. TENANCY AREAS – 600 x 1200 MID RANGE MINERAL FIBRE CEILING TILE IN DONN TWO WAY EXPOSED SUSPENDED GRID. ALLOW FOR SEISMIC BRACING TO STRUCTURAL ENGINEERS REQUIREMENTS. 7. ALLOW FOR 6 no. RONDO PANTHER CEILING HATCHES IN LOCATIONS TO SUIT HYDRAULIC/MECHANICAL ENGINEERS REQUIREMENT. 8. 19x19mm PAINTED TIMBER BEAD AT WALL/CEILING JUNCTION THROUGHOUT WC AND WC LOBBY AREAS TYPICAL 12mm DECORTECH FIRESAFE PLYWOOD CEILING - BLONDED FINISH 6mm HARDIFLEX SOFFIT LINING WITH NEGATIVE JOINTS HF FIRE RATED WALL, REFER FIRE ENGINEERS REPORT. FIRE RATED CONSTRUCTION TO EXTEND TO SOFFIT OR UNDERSIDE OF ROOF CLADDING, NOTCH AROUND ROOF FRAMING AND SEAL ALL AROUND WITH INTUMESCENT SEALANT CEILING HEIGHT TO UNDERSIDE OF FRAMING 2720 ACCESS PANEL AP EXTRACT GRILLE, REFER MECHANICAL ENGINEERS DOCUMENTATION SUPPLY GRILLE, REFER MECHANICAL ENGINEERS DOCUMENTATION RJC RESILIENT SHADOWLINE JOINT IN CEILING AT JUNCTION WITH WALLS RJW RESILIENT VERTICAL CONTROL JOINT WHERE GIB SUBSTRATE CHANGES FROM TIMBER FRAMING TO CONCRETE ent r y RJC DP2 1no. LAYER 13mm GIB AQUALINE TO WASH HAND BASIN WALL ONLY pr opos e d gr o und f loor pla r cpn A SCALE: 1:100 N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T REFLECTED CEILING PLANS 13/11/13 TH 15/03/2013 SL 1:100@A2 1:200@A4 4643 BUILDING CONSENT ISSUE A1.3 A BUILDING ENVELOPE RISK MATRIX West Elevation BUILDING ENVELOPE RISK MATRIX North Elevation FIXED AND OPENING ROOF LIGHTS, AS SPECIFIED Total Risk Score: A 1 Total Risk Score: COLORSTEEL CAPPING CONTINUES IN FRONT OF GABLE 1,560 C 14 1,125 3,650 W2.2 second floor ION PL E AN 11,375 WEST BOUNDARY 1,600 SS CE RE 800 W2.3 DOUBLE INSOL SOLARIS FINS ON PROPRIETARY ALUMINIUM BRACKETS 6600 120min FIRE RATED WINDOWS, AS SPECIFIED W1.4 PLASTER SYSTEM MOVEMENT JOINTS TO BE CONFIRMED ON SITE WITH ARCHITECT O/F W2.1 1,250 W2.4 VERTICAL COLORSTEEL STANDING SEAM CLADDING O/F 3,650 LINE OF EXISTING BUILDING OUTLINE SHOWN DASHED 2,400 COLORSTEEL ENDURA V-RIB ROOFING WITH MATCHING FLASHINGS AS SPECIFIED FAIRFACED PRECAST CONCRETE WALL WITH CLEAR IMPREGNATING SEALER SYSTEM AS SPECIFIED B Risk Severity Risk Score Medium risk 0 Very high risk 4 Very high risk 5 Very high risk 5 Low risk 0 Low risk 0 14 2,895 20 580 900 Risk Factor Wind zone (per NZS 3604) Number of storeys Roof/wall intersection design Eaves width Envelope complexity Deck design 50 1,075 2 Risk Severity Risk Score Medium risk 0 Very high risk 4 Very high risk 5 Very high risk 5 Low risk 0 Low risk 0 PROPRIETARY OVERFLOW SCUPPER, AS SPECIFIED TYPICAL COLORSTEEL CLAD WINDOW SILLS POWDERCOATED FACING AT STRUCTURAL POST LOCATIONS TYPICALLY SELECTED PLASTER FINISH 3,300 3 Risk Factor Wind zone (per NZS 3604) Number of storeys Roof/wall intersection design Eaves width Envelope complexity Deck design W1.1 W1.2 W1.3 first floor to d u r h a m st 3,300 CLEAR ANTI-GRAFFITI SYSTEM UP TO 2.4m, AS SPECIFIED W0.1 D0.1 NORTH BOUNDARY SOUTH BOUNDARY 3300 57° D0.2 ground floor 0 ea st e le v a tion SCALE: 1:100 SCALE: 1:100 300 1,100 BUILDING ENVELOPE RISK MATRIX West Elevation B SCALE: 1:100 Risk Factor Wind zone (per NZS 3604) Number of storeys Roof/wall intersection design Eaves width Envelope complexity Deck design A VERTICAL COLORSTEEL STANDING SEAM CLADDING ACID WASHED PRECAST WALLS AND COLUMN elev at ions k ey 0.55 COLORSTEEL ENDURA V-RIB ROOFING WITH MATCHING FLASHINGS AS SPECIFIED BUILDING ENVELOPE RISK MATRIX South Elevation Risk Severity Risk Score Medium risk 0 Very high risk 4 Very high risk 5 Very high risk 5 Low risk 0 Very high risk 6 Total Risk Score: COLORSTEEL PARAPET CAPPING DP1 nor th e le v a tion ba lus t r a de e le v a tion C DP2 SPANDREL PANELS TO BE SELECTED COLOUR TEMPACLAD TO OUTER PANE ZINC SPRAYED 100 PFC BOUNDARY RAILS, AS DETAILS AND SPECIFIED Risk Factor Wind zone (per NZS 3604) Number of storeys Roof/wall intersection design Eaves width Envelope complexity Deck design 1 20 Risk Severity Risk Score Medium risk 0 Very high risk 4 Very high risk 5 Very high risk 5 Low risk 0 Low risk 0 Total Risk Score: 14 FAIRFACED PRECAST CONCRETE WALL WITH CLEAR IMPREGNATING SEALER SYSTEM AS SPECIFIED FIXED AND OPENING ROOF LIGHTS, AS SPECIFIED 2 SELECTED PLASTER FINISH OVER FIBRE CEMENT BACKING SHEETS ON 20mm CAVITY OVER 90x45 TIMBER FRAMING. 3 ETERPAN TWO WAY FIRE WALL SYSTEM WITH 120/120/120 FIRE RATING, BUILT UP WITH 9mm ETERPAN , 20mm CAVITY, OVER 9mm ETERPAN RAB, 2no. LAYERS 60mm ETERCORE INSULATION AND 2no. 19mm GIB FYRELINE PLASTERBOARD LIFT OVER-RUN COLORSTEEL ENDURA V-RIB ROOFING WITH MATCHING FLASHINGS AS SPECIFIED O/F W2.5 PROPRIETARY OVERFLOW SCUPPER, AS SPECIFIED TYPICAL O/F SUNSHADE LOUVRES HOSE TAP, REFER HYDRAULIC ENGINEER DOCUMENTATION HT LINE OF EXISTING BUILDING OUTLINE SHOWN DASHED EWL EXTERNAL WEATHER LOUVRE, REFER MECHANICAL ENGINEER DOCUMENTATION LOCATION TO BE CONFIRMED ON SITE WITH ARCHITECT D#.# W#.# DOOR/WINDOW REFERENCE BY FLOOR LEVEL AND NUMBER, REFER DOOR AND WINDOW SCHEDULE W2.6 D2.1 METAL & GLASS BALUSTRADE second floor second floor 6,600 EWL SUNSHADE LOUVRES W1.5 W1.6 POWDERCOATED FACING AT STRUCTURAL POST LOCATIONS TYPICALLY W1.7 first floor 3300 NORTH BOUNDARY EWL SUNSHADE LOUVRES W0.2 W0.3 SOUTH BOUNDARY PRECAST CONCRETE WALLS D0.3 CLEAR ANTI-GRAFFITI SYSTEM UP TO 2.4m, AS SPECIFIED HT ground floor 0 FIXED SASH WINDOW WITH HEAD FLASHING & SILL FAIRFACED PRECAST CONCRETE WALL WITH CLEAR IMPREGNATING SEALER SYSTEM AS SPECIFIED WEST BOUNDARY RE CE SS ION PL AN E 6600 PRELIMINARY PRINT | 14/11/13 | 3:45 PM CLEAR ANTI-GRAFFITI SYSTEM UP TO 2.4m, AS SPECIFIED OPENING SASH WINDOW WITH HEAD FLASHING & SILL AREA OF '3M DUSTED CRYSTAL' OR APPROVED COLOURED FILM first floor 3,300 SELECTED 'TEMPACLAD' COLOURED GLASS TO OUTER PANE 57° to d u r h a m st CLEAR ANTI-GRAFFITI SYSTEM UP TO 2.4m, AS SPECIFIED ground floor 0 w e s t e le v a tion s o ut h e le v a tion SCALE: 1:100 SCALE: 1:100 A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T ELEVATIONS 13/11/13 TH 15/03/2013 SL 1:100@A2 1:200@A4 4643 BUILDING CONSENT ISSUE A2.1 A B 3,050 A STANDARD VALLEY GUTTER TO SMALL PITCHED ROOFING BEHIND LIFT SHAFT BUTYNOL ROOFING @ 2º MIN PITCH ON 17mm STRUCTURAL GRADE PLYWOOD ON 140x45mm MSG8 ROOF FRAMING @ 400mm CRS MAX BOTH WAYS. DRESS UP SIDES MIN 150mm TO FLASHING INTO SEALANT FILLED CONCRETE CHASE. B 3,050 DOUBLE GLAZED LOW PITCHED SKYLIGHTS ON TIMBER KERBS WITH FOLDED COLORSTEEL APRON FLASHINGS similar C 8,790 METAL ROOFING ON 90x45 TIMBER STRAPPING ON 300/15 DHS PURLINS ON CLEATS TO 360 UB PORTAL FRAMES 7 A4.1 850 MIN 150 ROOF PITCH 15º 7 A4.1 1,125 APEX A lif t ov er -r un BUYTL LINED INTERNAL GUTTER SET TO FALLS, REFER TO ROOF PLAN AND DETAILS. t e na nc y 3 t e na nc y 3 lo b b y CANTILEVERED GLASS BALUSTRADE TO STAIRS WITH SS DISC FIXINGS AND HANDRAILS ON STAND OFF BRACKETS 100mm THICK CONCRETE TOPPING SLAB ON 200mm THICK HOLLOWCORE 22,160 FFL 38 second floor 6,600 second floor 6,600 37 600 100mm THICK CONCRETE TOPPING SLAB ON 200mm THICK HOLLOWCORE. REFER TO STRUCTURAL ENG. DOCS. GIB SHEET CEILING ON SUSPENDED RAILS, RAKING WITH ROOF PITCH. 2,800 - PORTAL SPRING POINT FIRE RATED PLYWOOD CEILING LINING TO TOP OF STAIR WELL, REFER TO REFLECTED CEILING PLAN. 2,400 - CEILING SPRING POINT 3,650 3,650 GIB SHEET CEILING ON SUSP. RAIL SYSTEM, RAKING WITH ROOF PITCH. 3,650 4,500 FIRE RATED WALL CONTINUES UP TO UNDERSIDE OF ROOFING. REFER TO FIRE REPORT. 3,650 - TOP OF PARAPET 850 LIFTING BEAM ZONE 36 35 1,563 34 33 32 31 t e na nc y 2 lo b b y 100mm THICK CONCRETE TOPPING SLAB ON 200mm THICK HOLLOWCORE 19 first floor 3,300 GIB WALL LININGS OVER 45mm THICK STRAPPING WITH 40mm EPS INSULATION TO 200mm THICK PRECAST CONCRETE WALL PANELS. NORTH BOUNDARY t e na nc y 2 18,860 FFL first floor 3,300 15,560 FFL ground floor 0 18 600 lif t shaf t 2,700 CEILING SOUTH BOUNDARY 29 SOUTH BOUNDARY 3,300 30 17 16 15 14 200 13 2,650 400 12 11 t e na nc y 1 st or e ( unde r st air s) lo b b y FR SEALANT TO UNDERSIDE STAIR / GIB JUNCTION, REFER TO FIRE REPORT ground floor 0 2,700 CEILING 3,300 9 600mm THICK CONCRETE FLOOR SLAB. REFER TO STRUCTURAL ENGINEERS DOCUMENTATION. t e na nc y 1 600mm THICK CONCRETE FLOOR SLAB. REFER TO STRUCTURAL ENGINEERS DOCUMENTATION. lif t pit 25 1,100 60 Min FRR WALL TO STAIRS. LINE WITH 13mm GIB FYRELINE TO BOTH SIDES. REFER TO FIRE REPORT. 10 S e c t io n B S e c t io n A PRELIMINARY PRINT | 14/11/13 | 3:45 PM SCALE: 1:50 SCALE: 1:50 A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T SECTIONS A & B 13/11/13 TH 15/03/2013 SF 1:50 @A2 1:100@A4 4643 BUILDING CONSENT ISSUE A3.1 A 2 1 3 21,400 BUTYNOL ROOFING @ 2º MIN PITCH ON 17mm STRUCTURAL GRADE PLYWOOD ON 140x45mm MSG8 ROOF FRAMING @ 400mm CRS MAX BOTH WAYS. DRESSED DOWN OVER 50x50 ALUM. ANGLE TO FORM DRIP EDGE TO GUTTER. COLORSTEEL BARGE / RIDGE FLASHINGS COLOURED TO MATCH ROOFING BUTYL ROOFING @ 2º MIN PITCH ON 17mm STRUCTURAL GRADE PLYWOOD ON 100x45 MSG8 ROOF FRAMING @ 400mm CRS MAX BOTH WAYS. 4 A4.2 7 A4.1 0.55 COLORSTEEL APRON FLASHING UP MIN 110mm INTO SEALANT FILLED CHASE IN CONC, 2 CRESTS MIN COVER OVER PROFILED ROOFING. DOUBLE GLAZED LOW PITCHED SKYLIGHTS ON TIMBER KERBS WITH FOLDED COLORSTEEL APRON FLASHINGS 0.55 COLORSTEEL APRON FLASHING LAPS UP UNDER 0.55 COLORSTEEL FOLDED PARAPET CAPPING. ROOF PITCH 15º LIFTING BEAM ZONE 5 A4.2 1,220 2 A4.2 199 SUNSHADE LOUVRES OVER REAR WINDOWS. INSOL ZENITH MODULAR similar 850 COLORSTEEL PARAPET CAP FLASHING COLOURED TO MATCH WALL CLADDING METAL ROOFING ON 70x45 TIMBER PACKING ON 300/15 DHS PURLINS ON CLEATS TO 360 UB PORTAL FRAMES 2,160 9mm FIBRE CEMENT WALL CLADDING OVER 20mm MIN CAVITY OVER 120min FRR WALL STRUCTURE. REFER TO ELEVATION SHEET A2.1 FOR SETOUT OF EXPRESSED JOINTS. STAIR 1:- Accessible stair 3/6 A4.2 Construction: Precast Concrete stair 22,160 FFL 1,855 FIREPRO BJ201 (OSA) FLEXIBLE FIRE RESISTANT BARRIER TO WALL FRAMING BETWEEN FLOORS TO MAINTAIN 120min FRR. 100mm THICK CONCRETE TOPPING SLAB ON 200mm THICK HOLLOWCORE 50 lo b b y COLORSTEEL CLAD WINDOW SILLS OVER PLYWOOD SUBSTRATE. 9 A4.2 575 3,650 VARIES - RAKING 2,320 TEA SINK wc lo b b y 2x19mm GIB FYRELINE WALL LININGS OVER 140mm TIMBER FRAMING TO ACHIEVE 120 Min FRR. b a lc o ny FALL wc 8 A4.2 GIB SHEET CEILING ON SUSPENDED RAILS, RAKING WITH ROOF PITCH. Max 180 Min 310 Min 285 Max 25 Max rise 2500 900 PROPRIETARY ALUMINIUM POST & HANDRAIL BALUSTRADE WITH GLAZING BETWEEN. t e na nc y 3 Risers: 173.68 Treads: 310 Going: 285 Nosing: 25 Total Rise: 3300 1,100 1,100 2,420 3,451 LIQUID APPLIED MEMBRANE OVER CONC TO FALLS ON BALCONY. MINIMUM 150mm UPSTAND TO WALLS. 2,420 100 2x19mm GIB FYRELINE LININGS AROUND TOP STEEL MEMBERS CONT. UP TO UNDERSIDE OF BUYTL ROOF FRAMING 38 second floor 6,600 36 35 34 30 26 25 24 900 22 100mm THICK CONCRETE TOPPING SLAB ON 200mm THICK HOLLOWCORE 21 20 16 15 14 13 16mm GIB FYRELINE TO RAKING CEILING 3,300 9 wc lo b b y EXPOSED AGGREGATE PAVING REFER TO SITEWORKS PLAN 7 INTUMESCENT PAINT FOR 60Min FRR TO STEEL POST AND BEAM BELOW STAIR LANDING. 15 65 6 5 4 3 600mm THICK CONCRETE FLOOR SLAB. REFER TO STRUCTURAL ENGINEERS DOCUMENTATION. MIN 150 ent r y 8 lo b b y 13mm GIB FYRELINE TO INSIDE FACE OF STORE 150 400 900 TEA SINK 10 2,700 wc 8 A4.2 50mm SOFFIT BOARD XPS INSULATION TO UNDERSIDE OF FLOOR SLAB AS SPECIFIED. 3 A4.1 11 2,700 2,300 SITE BOUNDARY - WEST 12 t e na nc y 1 410 similar 900 600 17 140 first floor 3,300 2,100 HEADROOM 19 18 13mm GIB WALL LININGS OVER 70mm THICK STRAPPING TO 300mm THICK PRECAST CONCRETE SHEARWALL, TO ALIGN WITH FIRE RATED WALL. 9 A4.2 50 23 SUNSHADE LOUVRES OVER REAR WINDOWS. INSOL ZENITH MODULAR 13mm GIB FYRELINE WALL LININGS EACH SIDE TO MAINTAIN 60min FRR. 700 Max 575 lo b b y 600 3,300 lif t shaf t STEEL STRUCTURE WITHIN WALL FRAMING TO SUPPORT STAIRS. REFER TO STRUCTURAL DRAWINGS. 27 600 RE CE SS IO wc lo b b y 8 A4.2 2,700 wc TEA SINK 2,700 NP LA NE t e na nc y 2 29 28 18,860 FFL 2 1 4 A4.1 15,560 FFL ground floor 0 1,100 15,610 DOUBLE INSOL SOLARIS 300 VERTICAL LOUVRE BLADES ON PROPRIETARY ALUMINIUM CLASP BRACKETS. POWDER COATED FINISH. 900 31 2,700 300mm THICK INSITU CONCRETE SHEARWALL. REFER TO STRUCTURAL ENGINEERS DOCUMENTATION. 32 50mm SOFFIT BOARD XPS INSULATION TO UNDERSIDE OF FLOOR SYSTEM BELOW EXTERIOR BALCONY AS SPECIFIED. 1,855 33 2,700 8 A4.1 57° 820 600 600 600 250 37 lif t pit S e c t io n C PRELIMINARY PRINT | 14/11/13 | 3:45 PM SCALE: 1:50 A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T SECTION C 13/11/13 TH 15/03/2013 SL 1:50@A2 1:200@A4 4643 BUILDING CONSENT ISSUE A3.2 A 2 1 METAL ROOFING ON 90x45 TIMBER STRAPPING ON 300/15 DHS PURLINS ON CLEATS TO 360 UB PORTAL FRAMES COLORSTEEL BARGE / RIDGE FLASHINGS COLOURED TO MATCH ROOFING 4 A4.2 BUTYNOL ROOFING @ 2º MIN PITCH ON 17mm STRUCTURAL GRADE PLYWOOD ON 100x45 MSG8 ROOF FRAMING @ 400mm CRS MAX BOTH WAYS. ROOF PITCH 15º 2 A4.2 170 900 1,855 50 575 820 1,855 50 18,860 FFL first floor 3,300 1,200 750 first floor 3,300 SELECTED PLASTER FINISH OVER FIBRE CEMENT BACKING SHEETS ON 20mm CAVITY OVER 90x45 TIMBER FRAMING. FIREPRO BJ201 (OSA) FLEXIBLE FIRE RESISTANT BARRIER TO WALL FRAMING BETWEEN FLOORS TO MAINTAIN 120min FRR. 575 800 800 2,480 1,600 8 A4.2 100mm THICK CONCRETE TOPPING SLAB ON 200mm THICK HOLLOWCORE similar 600mm THICK CONCRETE FLOOR SLAB. REFER TO STRUCTURAL ENGINEERS DOCUMENTATION. 15,560 FFL SCALE: 1:50 1,650 t e na nc y 1 2 A4.1 ground floor 0 6mm HARDIFLEX ON TIMBER SOFFIT FRAMING 900 1,300 DOUBLE GLAZED ALUMINIUM WINDOW JOINERY, REFER TO DETAILS. OPAQUE GLAZING TO LOWER PANES. t e na nc y 1 8 A4.2 1 A4.1 2,700 125 PFC OR 100x50 RHS SUPPORT STEELWORK ABOVE AND BELOW WINDOWS, REFER TO STRUCTURAL ENG. DOCS. S e c t io n D PRELIMINARY PRINT | 14/11/13 | 3:45 PM 9 A4.2 second floor 6,600 t e na nc y 2 800 MIN 152 15,610 22,160 FFL 1,600 1,300 NE t e na nc y 2 EXPOSED AGGREGATE PAVING REFER TO SITEWORKS PLAN 6 A4.3 COLORSTEEL CLAD WINDOW SILLS OVER 20mm PLYWOOD SUBSTRATE ON 90x45 TIMBER FRAMING. 750mm DEEP x 400 WIDE INSITU CONCRETE BEAM. REFER STRUCT. ENGINEERS DOCUMENTATION. 2x19mm GIB FYRELINE WALL LININGS OVER 140mm TIMBER FRAMING TO ACHIEVE 120 Min FRR. NP LA WEST BOUNDARY 2,300 5 A4.3 second floor 6,600 900 50 250 22,160 FFL 4 A4.3 1/2 A4.3 100mm THICK CONCRETE TOPPING SLAB ON 200mm THICK HOLLOWCORE 3/6 A4.2 18,860 FFL 57° t e na nc y 3 2,480 FALL t e na nc y 3 600 b a lc o ny 175 800 1,100 5 A4.3 RE CE SS IO 8 A4.2 800 1,450 METAL FLASHING INTO CHASE IN PRECAST WALL TO TERMINATE WATERPROOFING MEMBRANE MIN 150mm ABOVE BALCONY. SUNSHADE LOUVRES OVER REAR WINDOWS. INSOL ZENITH MODULAR GIB SHEET CEILING ON SUSPENDED RAILS, RAKING WITH ROOF PITCH. 4 A4.3 LIQUID APPLIED MEMBRANE OVER CONC TO FALLS ON BALCONY. MINIMUM 150mm UPSTAND TO WALLS. DOUBLE GLAZED ALUMINIUM WINDOW JOINERY, REFER TO DETAILS. 7 A4.2 1,220 CUSTOM DESIGNED TIMBER ROOF TRUSS TO GABLE END. 45mm STRAPPING TO INSIDE FACE AS SHOWN. similar 9mm FIBRE CEMENT WALL CLADDING OVER 20mm MIN CAVITY OVER 9mm FIBRE CEMENT RAB BOARD ON 140mm WALL STRUCTURE. REFER TO ELEVATION SHEET A2.1 FOR SETOUT OF EXPRESSED JOINTS. 4 A4.2 COLORSTEEL PARAPET CAP FLASHING COLOURED TO MATCH WALL CLADDING 9mm FIBRE CEMENT WALL CLADDING OVER 20mm MIN CAVITY OVER 9mm FIBRE CEMENT RAB BOARD ON 140mm WALL STRUCTURE. REFER TO ELEVATION SHEET A2.1 FOR SETOUT OF EXPRESSED JOINTS. 9 A4.1 COLORSTEEL BARGE / RIDGE FLASHINGS COLOURED TO MATCH ROOFING 5 A4.2 COLORSTEEL PARAPET CAP FLASHING TO SELECTED COLOUR REFER SCHEDULE. PROPRIETARY ALUMINIUM POST & HANDRAIL BALUSTRADE WITH GLAZING BETWEEN. 3 15,560 FFL ground floor 0 S e c t io n E SCALE: 1:50 A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T SECTIONS D & E 13/11/13 TH 15/03/2013 SF 1:50@A2 1:200@A4 4643 BUILDING CONSENT ISSUE A3.3 A 200 15 25mm THICK TIMBER REVEALS GROOVED FOR LININGS VANTAGE ALUM. REVEAL ADAPTER TO WINDOW SUITE. PC TO MATCH FRAMES. 25 1 75 100 100mm APL VANTAGE FLUSH GLAZED ALUMINIUM WINDOW MULLION TO MAGNUM 50 HINGED DOOR FRAME. ALL WITH DOUBLE GLAZING. DRIP EDGE CAST 15mm WIDE 10mm DEEP REBATE INTO HEAD ONLY (NOT REQUIRED FOR JAMBS) 10 13mm STD GIB BOARD WALL LININGS OVER STRAPPING OVER DPC TO CONC WALLS ROOF PITCH 15° 40 w indow detail: head / jamb to insitu c onc 5 A3.3 Sc a le : 1: 5 PARAPET SLOPE 10° Min 50 R5.0 FIBREGLASS BATTS INSULATION FITTED NEATLY BETWEEN DHS PURLINS ON FOIL ON 50mm GALV WIRE MESH SCREW FIXED TO UNDERSIDE OF DHS PURLINS. ALLOW EXTRA FOR DAN BAND STRAPPING AT MID SPAN OF EACH WIRE MESH SHEET. 100mm APL VANTAGE FLUSH GLAZED ALUMINIUM WINDOW MULLION TO MAGNUM 50 HINGED DOOR FRAME. ALL WITH DOUBLE GLAZING. 100mm APL VANTAGE FLUSH GLAZED ALUMINIUM WINDOW SUITE WITH DOUBLE GLAZING. POWDER COATED FINISH. 70 1.5mm BUTYL ROOFING OVER MIN 17mm CD STRUCTURAL GRADE PLYWOOD SUBSTRATE TO MIN 1:100 GUTTER FALLS WITH 20mm TREATED TRIANGULAR TIMBER FILLETS TO ALL 90º UPSTANDS AS REQUIRED. SUPPORT FRAMING TO BE @400mm CRS MAX IN BOTH DIRECTIONS. DRESS UP 150mm MIN UNDER METAL FLASHING INTO SEALANT FILLED CONCRETE CHASE. HIGH POINT ~240 200 C 0.55 BMT COLOURSTEEL V-RIB PROFILE ROOFING OVER ROOFING UNDERLAY. FIX THRU RIB CREST ONLY WITH 14G x 55mm SCREWS INTO MIN 70x45mm TIMBER BATTENS OVER 300 DHS STEEL PURLINS Min 150 40mm FOAMULAR EPS WALL INSULATION NEATLY FITTED BETWEEN 70x45mm MSG8 THICK TIMBER STRAPPING. 2 400mm THICK INSITU CONC BEAM OR WALL. REFER TO STRUCT ENG. DRAWINGS. 50 Min 2 w indow detail: mullion to door jamb A1.1 Sc a le : 1: 5 LOW POINT SUMP 360 UB PORTAL FRAME. REFER TO STRUCTURAL ENG. DOCUMENTATION. UB P ORTA L 100mm APL VANTAGE FLUSH GLAZED ALUMINIUM WINDOW SILL OVER SILL TRAY WITH DOUBLE GLAZING. POWDER COATED FINISH. 100 150 REFER TO STRUCTUAL ENG. DRAWINGS FOR SLAB AND FOUNDATION DETAILS 360 VEHICLE GRADE ASPHALT TO FORECOURT AREA TO EDGES AS SHOWN ON CIVIL ENG. DRAWINGS. 75 13mm STANDARD GIB BOARD CEILINGS ON RONDO STEEL SUSPENSION SYSTEM FIXED TO DHS PURLINS ABOVE, RAKING WITH THE SLOPE OF THE PORTAL FRAMES. AP40 200 2800 AFL 380 PFC 2400 AFL GIB GOLDLINE PLATINUM TRIM TO CREATE NEGATIVE DETAIL AT WALL JUNCTIONS. w indo w detail: sill at slab edge 200 200 DRIP EDGE CAST 15mm WIDE 10mm DEEP REBATE INTO HEAD ONLY (NOT REQUIRED FOR JAMBS) 10 13mm STD GIB BOARD WALL LININGS OVER STRAPPING OVER DPC TO CONC WALLS 15 25mm THICK TIMBER REVEALS GROOVED FOR LININGS 75 100 70 1 LIQUID APPLIED BALCONY MEMBRANE OVER CONCRETE SET TO 2º FALL TO EXTERIOR. 125 100 200mm THICK HOLLOWCORE STRUCTURAL FLOOR SYSTEM 40 DRIP EDGE TO UNDERSIDE OF CONC BEAM 150 PRELIMINARY PRINT | 14/11/13 | 3:45 PM 15 50 20 SITE CONCRETE OVER FOUNDATIONS TO REQUIRED LEVELS. 50 200mm THICK HOLLOWCORE STRUCTURAL FLOOR SYSTEM 50 MIN GAP 12mm 20mm MAX HEAVY DUTY ANODISED ALUM RIBBED DOOR THRESHOLD, RAVEN RP19 OSA. 50 25 100mm THICK EXPOSED AGGREGATE CONCRETE PAVING STRIP TO FRONT OF GROUND FLOOR WINDOWS 300 SELECTED DRAINAGE CHANNEL AT DOOR THRESHOLD MIN 150mm DEEP. APL VANTAGE MAGNUM 50 HINGED DOOR WITH DOUBLE GLAZING. POWDER COAT FINISH 300mm THICK PRECAST CONCRETE SHEAR WALL. REFER TO STRUCTURAL ENG. DOCUMENTATION. AP65 15 CLADDING ADHESIVE FIXED OVER FOLDED GALV BACK FLASHING INTO SEALANT FILLED CHASE ON XPRESSCLAD ZED RAIL (XZR) 2x19mm GIB FYRELINE WALL LINING OVER TIMBER FRAMING AS PART OF FIRE RATED WALL 9.0mm FIBRE CEMENT WALL CLADDING WITH EXPRESSED JOINTS ON XPRESSCLAD CAVITY BATTEN SYSTEM OVER 9.0mm ETERPAN FIBRE CEMENT SHEETS AS RAB ON 140x45 MSG8 TIMBER FRAMING. 275 4 LIQUID APPLIED BALCONY MEMBRANE OVER CONCRETE SET TO 2º FALL TO EXTERIOR. SELECTED ALUMINIUM POST & RAIL BALUSTRADE WITH GLASS PANELS. 200 100 SELECTED ALUMINIUM POST & RAIL BALUSTRADE WITH GLASS PANELS. door detail: door head REFER TO STRUCTUAL ENG. DRAWINGS FOR SLAB AND FOUNDATION DETAILS detail: inter nal gutter - typical 1 A3.2 Sc a le : 1: 5 SELECTED ENTRANCE MAT ON FLC AS REQUIRED WITH SCREW FIXED 12x3mm ALUMINIUM ANGLE TRIM; ANODISED FINISH 7 A3.1 Sc a le : 1: 10 40 APL VANTAGE MAGNUM 50 HINGED DOOR WITH DOUBLE GLAZING. POWDER COAT FINISH 3 w indow detail: sout h entr y door jamb to pr ecast A1.1 Sc a le : 1: 5 100mm APL VANTAGE FLUSH GLAZED ALUMINIUM WINDOW SUITE WITH DOOR ADAPTER FRAME TO MAGNUM 50. POWDER COATED FINISH. VANTAGE ALUM. REVEAL ADAPTER TO WINDOW SUITE. PC TO MATCH FRAMES. 25 6 SHEET INSULATION GAP 5 40mm FOAMULAR EPS WALL INSULATION NEATLY FITTED BETWEEN 70x45mm MSG8 THICK TIMBER STRAPPING. 100mm Ø PVC DOWNPIPE OFFSET TO PASS THROUGH CENTRE OF 380 PFC BEAMS BELOW. CLAMP RING ROOF DRAIN WITH FLAT GRATE FITTED TO ROOF SUMP ABOVE. 400mm THICK INSITU CONC BEAM OR WALL. REFER TO STRUCT ENG. DRAWINGS. 125 2 A3.3 Sc a le : 1: 5 door detail: entr y t hr eshold / door sill 8 A3.2 Sc a le : 1: 5 w indow detail: head / jamb to insitu c onc 9 A3.2 sc ale: 1: 5 w indow detail: head / jamb to insitu c onc A3.3 sc ale: 1: 5 A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T DETAILS 13/11/13 TH 15/03/2013 SF 1:5 @A2 1:10@A4 4643 BUILDING CONSENT ISSUE A4.1 A 200mm THICK PRECAST CONC WALL PANELS 3 140 35 90 195 BUTYL ROOFING MEMBRANE VERTICALLY UP SIDES ON 9mm TREATED PLYWOOD SUBSTRATE OR PRECAST CONCRETE PANELS WITH 20mm TREATED TRIANGULAR TIMBER FILLETS TO ALL 90º UPSTANDS AS REQUIRED. OUTLINE OF SADDLE FLASHING OVER SHOWN DASHED BELOW PARAPET CAP FLASHING. VENTED VERMIN TRAY MIN 20mm FROM BOT. EDGE OF F.C. SHEET. 0.55 BMT FOLDED COLORSTEEL FLASHING OVER 9mm PLYWOOD SUBSTRATE TO MIN 5º SLOPE. UNDERLAY TO PROVIDE SEPARATION OF FLASHING & TIMBER. MIN SLOPE 5° VERTICAL COLORSTEEL 'EUROLINE' STANDING SEAM ON SELECTED BUILDING WRAP ON MIN 15mm PLYWOOD SUBSTRATE OVER 20mm CAVITY BATTENS ON BUILDING WRAP. REFER TO MANUFACTURERS DOCUMENTATION. detail: par apet wall / pr ecast junct ion A1.2 sc ale: 1: 5 50 RESILIENT SHADOWLINE NEGATIVE AT CEILING TO WALL JUNCTIONS. 9.0mm FIBRE CEMENT WALL CLADDING WITH EXPRESSED JOINTS ON XPRESSCLAD CAVITY BATTEN SYSTEM OVER 9.0mm ETERPAN FIBRE CEMENT SHEETS AS RAB ON 140x45 MSG8 TIMBER FRAMING. 1 VERTICAL COLORSTEEL 'EUROLINE' STANDING SEAM ON SELECTED BUILDING WRAP ON MIN 15mm PLYWOOD SUBSTRATE OVER 20mm CAVITY BATTENS ON BUILDING WRAP. REFER TO MANUFACTURERS DOCUMENTATION. 90 35 75 MIN MIN COVER GAP 110 MIN TOTAL 40 120 CLADDING ADHESIVE FIXED OVER FOLDED GALV BACK FLASHING INTO SEALANT FILLED CHASE ON XPRESSCLAD ZED RAIL (XZR) 0.55 BMT V-RIB PROFILE COLORSTEEL METAL ROOFING OVER SELF-SUPPORTING ROOFING UNDERLAY. SCREW FIXED THRU RIB CRESTS ONLY; ALLOW FOR THERMAL MOVEMENT FIXING AS REQUIRED. 80 2 CRESTS MIN LAP 100 MIN GAP 5 70 MIN 0.55 BMT FOLDED COLORSTEEL FLASHING OVER ROOFING WITH MIN 2 CRESTS COVER, TURNED DOWN OVER STAND SEAM CLADDING AS SHOWN detail: bar ge / st anding seam 4 25 DASHED LINES INDICATE LINE OF 360UB PORTAL FRAME SELECTED PLASTER FINISH OVER 9mm JH MONOTEK FIBRE CEMENT SHEET WALL CLADDING SYSTEM ON 20mm NOM WALL CAVITY BATTENS OVER WALL UNDERLAY. ALL AS OUTLINED WITHIN SPECIFICATION. A3.3 sc ale: 1: 5 13mm STD GIB WALL LINING OVER 140x45mm MSG8 TIMBER FRAMING 0.55 BMT FOLDED COLORSTEEL CAPPING TO MIN 5º SLOPE. FIXING THRU SIDES ONLY. UNDERLAY TO PROVIDE SEPARATION OF CAPPING AND TIMBER. MIN SLOPE 5° 70 MIN 70 MIN 7 VENTED VERMIN TRAY MIN 20mm FROM BOTTOM OF CLADDING, FLASHING TAPE OVER TOP TO BUILDING WRAP. 140 13mm STD GIB WALL LINING OVER 140mm TIMBER FRAMING HIGH POINT COLORSTEEL FOLDED OVER FLASHING LAPS DOWN OVER BUTYL ROOFING MEMBRANE BELOW. 9.0mm FIBRE CEMENT WALL CLADDING WITH EXPRESSED JOINTS ON XPRESSCLAD CAVITY BATTEN SYSTEM OVER 9.0mm ETERPAN FIBRE CEMENT SHEETS AS RAB ON 140x45 MSG8 TIMBER FRAMING. CLIP-ONFOOT TRAY TO BOTTOM EDGE OF FIBRE CEMENT SHEET. detail: st anding seam / butyl r oof ing 5 COLORSTEEL BACK FLASHING DOWN OVER HEAD FLASHING 8 DOUBLE INSOL SOLARIS 300 VERTICAL LOUVRE BLADES. SELECTED POWDER COAT FINISH. SUPPLIED AND INSTALLED BY INSOL NZ (0800 34 6000). 7.5 WANZ SUPPORT BAR TO DOOR FRAME, OSA. LIQUID APPLIED BALCONY MEMBRANE OVER CONCRETE SET TO 2º FALL TO EXTERIOR. SELECTED ADHESIVE FIXED TIMBER SKIRTING TRIM WALL WRAP DRESSED INTO AND AROUND OPENING, APPLY FLEXIBLE FLASHING TAPE 100mm AT CORNERS AND TURN OUT 50mm MIN. INSOL PROPRIETARY CLASP BRACKET LOUVRE FIXING SYSTEM TO UNDERSIDE OF 75 x 50 UA. 25mm THICK TIMBER REVEALS GROOVED FOR LININGS SILL FLASHING STOPENDED AT SIDES AND RETURNS AROUND CORNER AT FRONT EDGE INTO CAVITY. 19mm GIB FYRELINE WALL LINING ON 19mm TIMBER PACKER ON DPC OVER CONC NIB UPSTAND TO LINE WITH 2x19mm FIRE RATED WALL. SLOPE 0.55 BMT FOLDED COLORSTEEL FLASHING OVER 9mm PLYWOOD SUBSTRATE TO 10º SLOPE. UNDERLAY TO PROVIDE SEPARATION OF FLASHING & TIMBER. FRONT EDGE CONTINUES PAST 50mm AT SIDES. 10° 100x50 RHS LINTEL VARIATION DETAIL. REFER TO STRUCT. 50 Min 35 GAP COVED CORNER OVER BOND BREAKER APL VANTAGE MAGNUM 50 HINGED DOOR WITH DOUBLE GLAZING. POWDER COAT FINISH 100 MIN UPSTAND 50 2 LAYERS OF 60mm ETERCORE INSULATION WITHIN WALL FRAMING w indow detail: head / jamb to insitu c onc A3.3 sc ale: 1: 5 WATER VAPOUR AIR SEAL ON PEF RODS TO PERIMETER Min 150mm UPSTAND 2x19mm GIB FYRELINE WALL LINING OVER 140x45 TIMBER FRAMING TO ACHIEVE 120Min FRR WALL RATING, REFER TO SPECIFICATION. POWDERCOATED CHANNEL TO FIX TOP OF LOUVRES INTO, FIXED THRU SOFFIT INTO SOLID BLOCKING ABOVE. COLORSTEEL WINDOW HEAD FLASHING 40mm COMMERCIAL VANTAGE ALUMINIUM WINDOW SUITE WITH DOUBLE GLAZING. POWDER COATED FINISH. A3.3 sc ale: 1: 5 9.0mm FIBRE CEMENT WALL CLADDING WITH EXPRESSED JOINTS ON XPRESSCLAD CAVITY BATTEN SYSTEM OVER 9mm ETERPAN FIBRE CEMENT SHEETS ON BUILDING WRAP ON 140x45 MSG8 TIMBER FRAMING WITH 2 x 60mm ETERCORE INSULATION WITH 16mm FYRELINE LININGS TO INSIDE FACE. VENTED VERMIN TRAY MIN 20mm FROM BOT. EDGE OF F.C. SHEET. 20 MIN 100 6.0mm FIBRE CEMENT SOFFIT FOR PAINT FINISH WATER VAPOUR AIR SEAL ON PEF RODS TO PERIMETER 9.0mm FIBRE CEMENT CLADDING DOWN BACK FACE OF PARAPET, JUNCTION WITH 16mm GIB FYRELINE WITH FIRE RATED SEALANT. detail: west par apet / butyl r oof ing LAP FLASHING TAPE DOWN OVER CAVITY CLOSER WALL WRAP DRESSED INTO AND AROUND OPENING, APPLY FLEXIBLE FLASHING TAPE 100mm AT CORNERS AND TURN OUT 50mm MIN. 25mm THICK TIMBER REVEALS GROOVED FOR LININGS A3.2 sc ale: 1: 5 Min 150mm UPSTAND MIN 150 1.5mm BUTYL ROOFING OVER MIN 17mm CD STRUCTURAL GRADE PLYWOOD SUBSTRATE TO MIN 2º FALL WITH 20mm TREATED TRIANGULAR TIMBER FILLETS TO ALL 90º UPSTANDS AS REQUIRED. SUPPORT FRAMING TO BE @400mm CRS MAX IN BOTH DIRECTIONS. 100x50 RHS LINTEL VARIATION DETAIL. REFER TO STRUCT. 7.5 LOW POINT LIQUID APPLIED TRAFFICABLE WATERPROOFING MEMBRANE OVER CONCRETE SET TO 2º FALL TO EXTERIOR BALCONY. 90 150 PFC STEEL LOCATION WITH TIMBER PACKING TO SUIT. REFER TO STRUCT DOCUMENTATION. 50 MIN XPRESSCLAD VENTED ZED RAIL FOR FIXING BOTTOM OF F.C. CLADDING 320 50 ALLPROOF 200x75 ROOF SCUPPER AS OVERFLOW THRU WALL CLADDING. 2 w indow detail: head / jamb to insitu c onc A3.3 sc ale: 1: 5 SELECTED ADHESIVE FIXED TIMBER SKIRTING TRIM 150 PFC STEEL LOCATION WITH TIMBER PACKING TO SUIT. REFER TO STRUCT DOCUMENTATION. 25 13mm STD GIB WALL LINING OVER 140x45mm MSG8 TIMBER FRAMING PRELIMINARY PRINT | 14/11/13 | 3:45 PM 200mm THICK HOLLOWCORE STRUCTURAL FLOOR SYSTEM 3 200mm THICK HOLLOWCORE STRUCTURAL FLOOR SYSTEM detail: c onc nib up st and / wall 6 A3.2 sc ale: 1: 5 detail: c onc nib upst and / door sill A3.3 sc ale: 1: 5 140mm THICK WALL BATTS INSULATION. 20 20 100 320 DASHED LINES INDICATE 100 SHS POSTS WITHIN WALL FRAMING BEYOND. 9 90 20 SELECTED PLASTER FINISH OVER 9mm JH MONOTEK FIBRE CEMENT SHEET WALL CLADDING SYSTEM ON 20mm NOM WALL CAVITY BATTENS OVER WALL UNDERLAY. ALL AS OUTLINED WITHIN SPECIFICATION. w indow detail: head / jamb to insitu c onc A3.3 sc ale: 1: 5 A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T DETAILS 13/11/13 TH 15/03/2013 SF 1:5 @A2 1:10@A4 4643 BUILDING CONSENT ISSUE A4.2 A 1 CONTINUOUS BEAD OF FIRE RATED ADHESIVE SEALANT APPROVED AIRSEAL OVER PEF BACKING ROD 7.5 9mm ETERPAN PANEL. EDGE TO BE SEALED BEFORE WINDOW INSTALLED XPRESSCLAD ZED RAIL A1.1 50 15 SCALE: 1:5 4 A1.1 1 SELECTED 120 FIRE RATED STEEL GLAZING SYSTEM 25mm GROOVED FOR LININGS REVEALS FIRE RATED MASIC FLEXIBLE FLASHING TAPE VANTAGE 40mm SERIES ALUMINIUM FRAME WITH OPENING SASHES w indow detail: jamb to insitu c onc FIRE RATED MINERAL WOOL APPROVED AIRSEAL OVER PEF BACKING ROD 15x15 FOAM TAPE BY WINDOW INSTALLER FLASHING TAPE 100mm UPSTAND ON JAMB 1 0.7mm POWDER COATED ALUMINIUM HEAD FLASHING WITH 15deg FALL AND 10mm MIN. COVER TO WINDOW JOINERY 25mm GROOVED FOR LININGS REVEALS VANTAGE 40mm SERIES ALUMINIUM FRAME WITH OPENING SASHES 125 PFC BEAM WITH INTUMESCENT PAINT REFER STRUCTURAL & FIRE ENGINEER DOCUMENTATION CONTINUOUS UNBROKEN LINE OF SEALANT BEHIND FLASHING & 20mm STOP END 25mm GROOVED FOR LININGS REVEALS w indow detail: head to eter pan c ladding 25 SCALE: 1:5 300 25mm GROOVED FOR LININGS REVEALS VANTAGE 40mm SERIES ALUMINIUM FRAME VANTAGE 40mm SERIES ALUMINIUM FRAME WITH OPENING SASHES SUPPORT BLOCK BY WINDOW SUPPLIER CONTINUOUS BEAD OF FIRE RATED ADHESIVE SEALANT 2no. LAYERS 19mm GIB FYRELINE. INSTALLED TO MEET GIB FIRE RATED WALL SYSTEM GBUW120 9mm ETERPAN BASE PANEL ON FLAMESTOP 650 BUILDING WRAP PANEL TAK ADHESIVE SYSTEM WITH FOAM TAPE 100 SHS CONCRETE FILLED POST WITH INTUMESCENT PAINT TO EXTEND 100mm ABOVE AND BELOW WINDOW SUPPORT STEEL, REFER STRUCTURAL & FIRE ENGINEER DOCUMENTATION VENTILATED & DRAINED CAVITY (20mm) 5 LINE OF PRECAST CONCRETE OVER A1.1 A1.1 DRIP EDGE METAL ANGLE CONTINUOUS FIRE RATED MASTIC w indow detail: sill/ jamb to eter pan c ladding 25mm GROOVED FOR LININGS REVEALS CONTINUOUS FIRE RATED MASTIC FIRE RATED MINERAL WOOL SELECTED 120 FIRE RATED STEEL GLAZING SYSTEM SCALE: 1:5 50 A1.1 door detail: jamb to shs post SCALE: 1:5 40mm FOAMULAR EPS WALL INSULATION NEATLY FITTED BETWEEN 70x45mm MSG8 THICK TIMBER STRAPPING. 120/120/120 FIRE RATED PRECAST WALL (NO UNPROTECTED OPENINGS), REFER FIRE ENGINEER 9 2 SCALE: 1:5 WATERPROOF LIQUID MEMBRANE TO COMPLY WITH AS/NZS 4858 2no. LAYERS 19mm GIB FYRELINE. INSTALLED TO MEET GIB FIRE RATED WALL SYSTEM GBUW120 NOTE: SILL SUPPORT BAR TO SILL DETAIL UNDER WINDOW JOINERY WITH 5mm GAP TO WINDOW FLANGE AND PANEL VANTAGE MAGNUM 50 ALUMINIUM FRAME DOOR FR R w indow detail: jamb to pr ecast c onc C 125 PFC BEAM WITH INTUMESCENT PAINT REFER STRUCTURAL & FIRE ENGINEER DOCUMENTATION XPRESSCLAD ZED RAIL SOLID BLOCKING TO SUIT FACADE PANEL AND BATTEN THICKNESS OVER A1.1 APPROVED AIRSEAL OVER PEF BACKING ROD MIN. SOLID BLOCKING TO SUIT 10 9mm ETERPAN BASE PANEL ON FLAMESTOP 650 BUILDING WRAP POWDER COATED ALUMINIUM FLASHING 8 100 SHS POST BEYOND INDICATED WITH DASHED LINE FR R w indow detail: head to pr ecast c onc SCALE: 1:5 1 1 APL VANTAGE MAGNUM 50 HINGED DOOR WITH DOUBLE GLAZING. POWDER COAT FINISH 1 C 9mm ETERPAN BASE PANEL ON FLAMESTOP 650 BUILDING WRAP 50 9mm ETERPAN PANEL 1no. LAYER13mm STANDARD GIB WALL LINING ON TIMBER STRAPPING ON PRECAST CONCRETE WALL (LIMITED UNPROTECTED OPENINGS), REFER FIRE ENGINEER 3 A1.1 SCALE: 1:5 20 150 145 7 A1.1 DPC TO TIMBER STRAPPING SILL MEMBRANE TO EXTEND UP JAMBS 40mm MIN. AND APPLIED CONTINUOUSLY ACROSS FULL WIDTH OF OPENING 20 10 f oundat ion detail: eter pan c ladding 25mm GROOVED FOR LININGS REVEALS SLOPED PRECAST CONCRETE SILL 70 A1.1 A1.1 CONTINUOUS FIRE RATED MASTIC 40mm FOAMULAR EPS WALL INSULATION NEATLY FITTED BETWEEN 70x45mm MSG8 THICK TIMBER STRAPPING. 130 10 FR R w indow detail: sill to pr ecast c onc 210 210 6 door detail: jamb to insitu c onc 150 5 FIRE RATED CONTROL JOINT EXPOSED AGGREGATE FIN. TO EXTERIOR PAVING CONTINUOUS FIRE RATED MASTIC 5 SAW CUT 15mm DEEP x 6mm WIDE CHASE IN CONCRETE PANEL EXPOSED AGGREGATE FIN. TO EXTERIOR PAVING 145 FLASHING 70mm WIDE PANEL TAK ADHESIVE SYSTEM WITH FOAM TAPE 100 2no. LAYERS 19mm GIB FYRELINE. INSTALLED TO MEET GIB FIRE RATED WALL SYSTEM GBUW120 MIN. TO PAVED GROUND CONTINUOUS BEAD OF FIRE RATED ADHESIVE SEALANT 15 50 25mm GROOVED FOR LININGS REVEALS ETERPAN 9mm PRELIMINARY PRINT | 14/11/13 | 3:45 PM WANZ SUPPORT BAR TO DOOR FRAME, OSA. XPRESSCLAD ZED RAIL FIRE RATED MINERAL WOOL SELECTED 120 FIRE RATED STEEL GLAZING SYSTEM 15 INTERMEDIATE VERTICAL RUNNERS @ 600 CRS MAX VANTAGE MAGNUM 50 ALUMINIUM FRAME DOOR 1no. LAYER13mm STANDARD GIB WALL LINING ON TIMBER STRAPPING ON PRECAST CONCRETE WALL 25 5 DPC XPRESSCLAD HORIZONTAL RUNNER 25 BACK FLASHING 70mm WIDE 15 C 15 SAW CUT 15mm DEEP x 6mm WIDE CHASE IN CONCRETE PANEL CONTINUOUS FIRE RATED MASTIC 100 SHS POST BEYOND INDICATED WITH DASHED LINE 10 2no. LAYERS 19mm GIB FYRELINE. INSTALLED TO MEET GIB FIRE RATED WALL SYSTEM GBUW120 120/120/120 FIRE RATED WALL (NO UNPROTECTED OPENINGS), REFER FIRE ENGINEER MIN. 45 10 300 9mm ETERPAN BASE PANEL ON FLAMESTOP 650 BUILDING WRAP. WRAP DRESSED INTO OPENING WITH FLEXIBLE FLASHING TAPE INSTALLED OVER MIN. 1 SCALE: 1:5 door detail: f oundat ion SCALE: 1:5 SCALE: 1:5 A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T SLOPE PAVED AREA LEADING UP TO DOOR ENTRY DETAILS 13/11/13 TH 15/03/2013 SF 1:5 @A2 1:10@A4 4643 BUILDING CONSENT ISSUE A4.3 A 13mm STANDARD GIB PLASTERBOARD CEILING LINING WITH SELECTED SEMIGLOSS ENAMEL PAINT FINISH 90 WHB-1 750 GR-1 700 1 int er nal elev at ion SCALE 1:25 • SCALE 1:25 1,950 90 90 1,950 90 660 door leaf 2 int er nal elev at ion • SCALE 1:25 90 10 10 EQ SNK TAP 900 450 2,835 DW SELECTED 90 DEGREE GRAB RAIL INSTALLED TO COMPLY WITH NZS 4121 GR-2 SELECTED GRAB RAIL -INSTALLED TO COMPLY WITH NZS 4121 TRH-1 SELECTED TOILET TISSUE DISPENSER INSTALLED TO COMPLY WITH NZS 4121 SD-1 BOBRICK B-2111 SOAP DISPENSER or SIMILAR APPROVED PRINCIPAL SUPPLIED, FISHER & PAYKEL COMPACT STAINLESS STEEL FRIDGE/ FREEZER 248L, E249TRX HWC UNDERBENCH HOT WATER CYLINDER 45L, REFER MECHANICAL ENGINEER SNK 'MERCER' AMPIO STAINLESS STEEL RECTANGULAR BOWL SINK, 455x305x170(D)mm DW PRINCIPAL SUPPLIED, COMPACT 450mm WIDE DISHWASHER MW PRINCIPAL SUPPLIED, MICROWAVE 'JAECO' 305mm CHROME TEA TOWEL RAIL MOUNTED TO INSIDE OF DOOR PANEL, BASKET 'HAFELE' CHROME SOAP/CLEANERS BASKET MOUNTED TO INSIDE OF DOOR PANEL BIN 'HIDEAWAY' WASTE BIN PULL SYSTEM 1,790 1,170 620 adj adj adj adj adj MW TAP 10 30 FF SNK 900 T-RAIL HWC BASKET broom cupboard 100 10 350 1,010 400 - 2,400 20 370 50x10mm PAINTED TIMBER SKIRTING 650 SCALE 1:25 10 4 670 int er nal elev at ion • GR-1 650 360 650 360 FF broom cupboard 775 EQ SEAL PERIMETER OF WHB TO SURROUNDING WALL SURFACE, USING A COMPATIBLE SILICONE SEALANT WHB-2 3 METHVEN 'ECHO CIRCA' WASH HAND BASIN MIXER 1,800 1,805 (MAX) 1,000 SCALE 1:25 TAP-1 100 45 WC-2 CAROMA 'FAUN 450' WALL BASIN WITH SHROUD HWC 975 SELECTED SPLASHBACK SELECTED VINYL FLOORING 2no. LAYERS 19mm GIB FYRELINE PLASTERBOARD WALL LINING INSTALLED TO COMPLY WITH GIB FIRE RATED PROTECTION OF STEEL COLUMN WITH STEEL CLIP AND CHANNEL SYSTEM 10 TRH-1 unis e x w c plan - t ypical WHB-2 k it c he ne t t e f it t ings k e y 350 TAP-1 TAP-1 CAROMA 'FLORA 500' WALL BASIN WITH SHROUD 600 13mm GIB AQUALINE PLASTERBOARD CEILING LINING (TO WHB WALL ONLY) WITH SELECTED SEMI-GLOSS ENAMEL PAINT FINISH 13mm STANDARD GIB PLASTERBOARD WALL LINING (GENERALLY) WITH SELECTED SEMI-GLOSS ENAMEL PAINT FINISH TRH-1 WHB-1 T-RAIL 1,000 950 475 WHB-2 CAROMA 'OPAL' # 987073 WALL FACED CLOSE-COUPLED TOILET SUITE FF SEAL PERIMETER OF WC TO SURROUNDING WALL AND FLOOR SURFACE, USING A COMPATIBLE SILICONE SEALANT - 1.77 m2 300mm HIGH STAINLESS STEEL KICKPLATE TO CUBICLE SIDE OF DOOR ONLY 19x19mm PAINTED TIMBER BEAD AT WALL AND CEILING JUNCTION JUNCTION 90 3 WC-2 475 90 WHB-1 13mm STANDARD GIB PLASTERBOARD CEILING LINING WITH SELECTED SEMIGLOSS ENAMEL PAINT FINISH SAFETY MIRROR WITH POLISHED EDGES WC-2 100 90 450 45 WHB-1 50x10mm PAINTED TIMBER SKIRTING ac c essible w c plan - t ypical SELECTED GRAB RAIL ON CUBICLE SIDE OF DOOR GR-2 90 90 3.14 m2 TAP-1 SEAL PERIMETER OF WHB TO SURROUNDING WALL SURFACE, USING A COMPATIBLE SILICONE SEALANT (MAX) WC-1 810 door leaf TRH-1 PRIVACY LATCH AND LOCKSET, REFER HARDWARE SCHEDULE SELECTED SPLASHBACK 1,000 - 13mm GIB AQUALINE PLASTERBOARD CEILING LINING (TO WHB WALL ONLY) WITH SELECTED SEMI-GLOSS ENAMEL PAINT FINISH TAP-1 160 460 760 2 (MIN. CLEAR OPENING) 1,650 1,175 - CAROMA 'CARE 800' ACCESSIBLE WALL FACED CLOSE-COUPLED TOILET SUITE, INSTALLED TO COMPLY WITH NZS 4121 SIGNAGE TO EXTERNAL SIDE OF DOOR signage SD-1 1 WC-1 t ea s ink - t y pic al adj 650 WC-1 SAFETY MIRROR WITH POLISHED EDGES LINE OF WALL LINING SURROUND TO STEEL PORTAL ON SECOND FLOOR ONLY MW 140 10 30 350 TRH-1 SD-1 13mm STANDARD GIB PLASTERBOARD WALL LINING (GENERALLY) WITH SELECTED SEMI-GLOSS ENAMEL PAINT FINISH 19x19mm PAINTED TIMBER BEAD AT WALL AND CEILING JUNCTION JUNCTION 1,000 TAP-1 400 475 GR-1 (400mm MAX) 90 90 500 CUT UTL 150 975 DW BIN 470 750 1,650 90 100 225 500 (400mm MIN) 500 90 1,450 b a t hr o o m f it t ings k e y 13mm STANDARD GIB PLASTERBOARD CEILING LINING WITH SELECTED SEMIGLOSS ENAMEL PAINT FINISH 760 90 90 300 1,950 1,000 90 4 int er nal elev at ion • SCALE 1:25 PRELIMINARY PRINT | 14/11/13 | 3:45 PM SCALE 1:25 A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T INTERIORS - BATHROOM 13/11/13 TH 15/03/2013 SL 1:25@A2 1:50@A4 4643 BUILDING CONSENT ISSUE A5.1 A 910 DOOR NO. 1 A4.1 DOOR CLOSER 450 EQ 450 450 50 (1 OFF) D0.1 1,300 2,100 TC TC 450 EQ 450 EQ 450 EQ 450 810 1 A4.3 W0.2 2 A4.3 W0.3 2. REFER TO FLOOR PLANS FOR WALL TYPES AND THICKNESS 3. CHECK ALL OPENINGS ON SITE FOR SIZE AND STANDARD OF EXECUTION PRIOR TO MANUFACTURE. INSTALLATION TOLERANCES SUBJECT TO EARTHQUAKE DESIGN. 0.54 m2 800 0.54 m2 0.54 m2 POWDER COATED ALUMINIUM FLASHING COVER TO STEEL POST, TO MATCH WINDOW JOINERY COLOUR 5 A4.3 0.54 m2 TOTAL OPENING AREA: 10.34 m2 2 A4.1 (1 OFF) D0.2 3 A4.3 4. REFER TO SOPERS FOR DOOR HARDWARE TYPE AND FINISH. 5. FIX ALL PROPRIETARY ELEMENTS IN ACCORDANCE WITH THE DOOR MANUFACTURERS REQUIREMENTS. 6. SHOP DRAWINGS AND INSTALLATION DETAILS ARE TO BE PROVIDED AND APPROVED BY ARCHITECT PRIOR TO MANUFACTURE. 7. FLASHING, GENERALLY, TO MATCH WINDOW FRAMES. ENSURE MATERIALS USED FOR HEAD, JAMB & SILL FLASHINGS ARE COMPATIBLE WITH THE WINDOW FRAME MATERIALS, FIXINGS AND CLADDING MATERIALS. 8. GLAZING TO MEET 'HUMAN IMPACT SAFETY REQUIREMENTS - NZS 4223.3 9. GLAZING MANIFESTATIONS TO COMPLY WITH NZS 4223.3 120 0.54 m2 1.66 m2 D0.3 220 3M FILM MANIFESTATION (INDICATIVE ONLY) REFER TO FLOOR PLANS FOR DIRECTION OF DOOR SWING. DOOR CLOSER TC 900 1,000 220 1,000 220 1,650 120 3M FILM MANIFESTATION (INDICATIVE ONLY) 450 4 A4.3 TC 1. 7,390 120 5 A4.1 120 4 A4.1 EQ 2,550 6 A4.1 EQ 450 DOOR CLOSER 120 2,550 EXTERIOR DOOR S A LUMINIUM N E W DOOR S 3 A4.1 EQ 120 910 door notes -/120/120 FRR WALL - LIMITED UNPROTECTED OPENINGS 7,040 7 A4.3 1,000 1,555 3M FILM MANIFESTATION (INDICATIVE ONLY) (1 OFF) D0.3 (including W0.2, W0.3) LOCATION ENTRY (EAST) TENANCY 1 ENTRY (EAST) TENANCY 1 / COURTYARD (WEST) 10. ALL REQUIRED STIFFENERS SHALL BE INTERNAL AND TO BE APPROVED BY ARCHITECT FRAME VANTAGE 100mm FLUSHGLAZE SUITE ALUMINIUM FRAME WITH MAGNUM 50 HINGED DOOR VANTAGE 100mm FLUSHGLAZE SUITE ALUMINIUM FRAME WITH SIDE HING OPENING WINDOWS AND MAGNUM 50 HINGED DOOR VANTAGE 40mm SERIES ALUMINIUM FRAME WITH SIDE HUNG OPENING WINDOWS AND MAGMUM 50 HINGED DOOR 11. ALL HANDLES, LEVERS AND RECESSED PULLS SHALL BE CENTERED @ 1.0m AFL REVEALS 25mm GROOVED FOR LININGS REVEALS 25mm GROOVED FOR LININGS REVEALS 25mm GROOVED FOR LININGS REVEALS 12. ALLOW FOR WALL/FLOOR MOUNTED DOOR STOPS TO ALL DOORS. DOOR VANTAGE MAGNUM 50 HINGED DOOR WITH SQUARE BEAD GLAZED STILES. DOOR BOTTOM RAIL EXTENDER. VANTAGE MAGNUM 50 HINGED DOOR WITH SQUARE BEAD GLAZED STILES. DOOR BOTTOM RAIL EXTENDER. VANTAGE MAGNUM 50 HINGED DOOR WITH SQUARE BEAD GLAZED STILES. DOOR BOTTOM RAIL EXTENDER. GLAZING CLEAR LAMINATED DOUBLE GLAZED SAFETY GLASS TO COMPLY WITH NZS:4223 CLEAR LAMINATED DOUBLE GLAZED SAFETY GLASS TO COMPLY WITH NZS:4223 CLEAR LAMINATED DOUBLE GLAZED SAFETY GLASS TO COMPLY WITH NZS:4223 FINISH POWDER COATED ALUMINIUM FRAMES WITH PAINT FINISH REVEALS POWDER COATED ALUMINIUM FRAMES WITH PAINT FINISH REVEALS POWDER COATED ALUMINIUM FRAMES WITH PAINT FINISH REVEALS HARDWARE LATCH & LOCKSET, LEVER HANDLE, DOOR CLOSER, RAVEN THRESHOLD BAR FOR LEVEL THRESHOLD LATCH & LOCKSET, LEVER HANDLE, DOOR CLOSER, RESTRICTOR STAYS TO OPENING SASHES, RAVEN THRESHOLD BAR FOR LEVEL THRESHOLD LATCH & LOCKSET, LEVER HANDLE, DOOR CLOSER, RAVEN THRESHOLD BAR FOR LEVEL THRESHOLD NOTES ILLUMINATED EXIT SIGN OVER 3M FILM MANIFESTATION TO DOOR PANEL SPANDREL PANELS TO BE SELECTED COLOUR TEMPACLAD (TC) TO OUTER PANE. ILLUMINATED EXIT SIGN OVER. 3M FILM MANIFESTATION TO DOOR PANEL FIRE REPORT: THE MAXIMUM PERCENTAGE OF UNPROTECTED AREA FOR THE EXTERNAL WALL IS 30% OR 10m², WHICHEVER IS THE SMALLER. THE EXTERNAL WALLS INDICATED ON THE FIRE DRAWINGS SHALL BE FIRE RATED TO MEET THE ABOVE REQUIREMENTS. 3M FILM MANIFESTATION TO DOOR PANEL -/120/120 FRR WALL - LIMITED UNPROTECTED OPENINGS 9,750 7,390 450 450 EQ 450 1,450 120 DOOR CLOSER W2.6 POWDER COATED ALUMINIUM FLASHING COVER TO STEEL POST, TO MATCH WINDOW JOINERY COLOUR CONCRETE NIB UPSTAND DOOR NO. 120 D2.1 175 800 5 A4.3 6 A4.2 D2.1 (including W2.5, W2.6) 1,000 120 2,250 EXTERIOR DOOR S A LUMINIUM N E W DOOR S 4 A4.3 W2.5 450 810 EQ 450 EQ 450 EQ 450 8 A4.2 1,600 EQ W1.1 (W2.1) 800 450 W1.2 (W2.2) W1.3 (W2.3) 2,400 EQ EXTERIOR W INDOW S A LUMINIUM 450 NE W W INDOW S 450 POWDER COATED ALUMINIUM FLASHING COVER TO STEEL POST, TO MATCH WINDOW JOINERY COLOUR 9 A4.2 POWDER COATED ALUMINIUM FLASHING COVER TO STEEL POST, TO MATCH WINDOW JOINERY COLOUR 3M FILM MANIFESTATION (INDICATIVE ONLY) (1 OFF) WINDOW NO. W1.1 (including W1.2, W1.3) (2 OFF) W2.1 (including W2.2, W2.3) TENANCY 3 / BALCONY (WEST) LOCATION TENANCY 2, TENANCY 3 (EAST) FRAME VANTAGE 40mm SERIES ALUMINIUM FRAME WITH SIDE HUNG OPENING WINDOWS AND MAGMUM 50 HINGED DOOR FRAME VANTAGE 40mm SERIES ALUMINIUM FRAME WITH SIDE HUNG OPENING SASHES REVEALS 25mm GROOVED FOR LININGS REVEALS REVEALS 25mm GROOVED FOR LININGS REVEALS DOOR VANTAGE MAGNUM 50 HINGED DOOR WITH SQUARE BEAD GLAZED STILES DOOR - GLAZING CLEAR LAMINATED DOUBLE GLAZED SAFETY GLASS TO COMPLY WITH NZS:4223 GLAZING CLEAR LAMINATED DOUBLE GLAZED SAFETY GLASS TO COMPLY WITH NZS:4223 FINISH POWDER COATED ALUMINIUM FRAMES WITH PAINT FINISH REVEALS FINISH POWDER COATED ALUMINIUM FRAMES WITH PAINT FINISH REVEALS HARDWARE LATCH & LOCKSET, LEVER HANDLE, DOOR CLOSER HARDWARE NOTES FIRE REPORT: THE MAXIMUM PERCENTAGE OF UNPROTECTED AREA FOR THE EXTERNAL WALL IS 30% OR 10m², WHICHEVER IS THE SMALLER. THE EXTERNAL WALLS INDICATED ON THE FIRE DRAWINGS SHALL BE FIRE RATED TO MEET THE ABOVE REQUIREMENTS. 3M FILM MANIFESTATION TO DOOR PANEL NOTES PRELIMINARY PRINT | 14/11/13 | 3:45 PM LOCATION A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T DOOR & WINDOW SCHEDULE 13/11/13 TH 15/03/2013 SL 1:50@A2 1:100@A4 4643 BUILDING CONSENT ISSUE A7.1 A door notes -/120/120 FRR WALL - LIMITED UNPROTECTED OPENINGS EQ 400 EQ POWDER COATED ALUMINIUM FLASHING COVER TO STEEL POST 200 800 TOTAL OPENING AREA:9.61 m2 CIRCULAR VISION PANEL WITH ALUMINIUM GLAZING BEAD WINDOW NO. (1 OFF) W1.5 (including W1.6, W1.7) DOOR UNDERCUT, REFER MECHANICAL D0.5, D1.3, D2.3 DOOR NO. GRABRAIL TO CUBICLE SIDE OF DOOR ONLY (3 OFF) 300mm HIGH STAINLESS STEEL KICKPLATE TO CUBICLE SIDE OF DOOR ONLY 1,000 W1.7 710 1. REFER TO FLOOR PLANS FOR DIRECTION OF DOOR SWING. 2. REFER TO FLOOR PLANS FOR WALL TYPES AND THICKNESS 3. CHECK ALL OPENINGS ON SITE FOR SIZE AND STANDARD OF EXECUTION PRIOR TO MANUFACTURE. INSTALLATION TOLERANCES SUBJECT TO EARTHQUAKE DESIGN. 4. REFER TO SOPERS FOR DOOR HARDWARE TYPE AND FINISH. 5. FIX ALL PROPRIETARY ELEMENTS IN ACCORDANCE WITH THE DOOR MANUFACTURERS REQUIREMENTS. 6. SHOP DRAWINGS AND INSTALLATION DETAILS ARE TO BE PROVIDED AND APPROVED BY ARCHITECT PRIOR TO MANUFACTURE. 7. FLASHING, GENERALLY, TO MATCH WINDOW FRAMES. ENSURE MATERIALS USED FOR HEAD, JAMB & SILL FLASHINGS ARE COMPATIBLE WITH THE WINDOW FRAME MATERIALS, FIXINGS AND CLADDING MATERIALS. 8. GLAZING TO MEET 'HUMAN IMPACT SAFETY REQUIREMENTS - NZS 4223.3 9. GLAZING MANIFESTATIONS TO COMPLY WITH NZS 4223.3 200 W1.6 810 2,050 50 1,000 450 300 EQ 2,100 W1.5 450 2,050 EQ 1,000 450 400 EQ 810 910 2,050 450 100 1,400 50 4,950 INTERIOR D O O R S 450 1,300 50 100 N E W DOOR S 1,330 EXTERIOR W INDOW S A LUMINIUM NE W W INDOW S 7,390 D0.6, D1.4, D2.4 (3 OFF) D0.7, D1.5, D2.5 (3 OFF) LOCATION TENANCY 2 LOCATION WC LOBBY ACCESSIBLE WC WC 10. ALL REQUIRED STIFFENERS SHALL BE INTERNAL AND TO BE APPROVED BY ARCHITECT FRAME VANTAGE 40mm SERIES ALUMINIUM FRAME WITH SIDE HUNG OPENING SASHES FRAME 40x150mm PINUS CLEARS TO SUIT LININGS OVER 90 FRAMED WALL 40x150mm PINUS CLEARS TO SUIT LININGS OVER 90 FRAMED WALL 40x150mm PINUS CLEARS TO SUIT LININGS OVER 90 FRAMED WALL 11. ALL HANDLES, LEVERS AND RECESSED PULLS SHALL BE CENTERED @ 1.0m AFL REVEALS 25mm GROOVED FOR LININGS REVEALS REVEALS 40mm GROOVED FOR LININGS REVEALS 40mm GROOVED FOR LININGS REVEALS 40mm GROOVED FOR LININGS REVEALS 12. ALLOW FOR WALL/FLOOR MOUNTED DOOR STOPS TO ALL DOORS. DOOR - DOOR 38mm THICK SOLID CORE DOOR FOR PAINT FINISH 38mm THICK SOLID CORE DOOR FOR PAINT FINISH 38mm THICK SOLID CORE DOOR FOR PAINT FINISH GLAZING CLEAR LAMINATED DOUBLE GLAZED SAFETY GLASS TO COMPLY WITH NZS:4223 GLAZING MILK WHITE LAMINATED OBSURE VISION PANEL WITH SATIN SILVER ANODISED BEAD - - FINISH POWDER COATED ALUMINIUM FRAMES WITH PAINT FINISH REVEALS FINISH PAINT FINISH DOOR AND FRAME PAINT FINISH DOOR AND FRAME PAINT FINISH DOOR AND FRAME HARDWARE HARDWARE LATCH, LEVER HANDLE PRIVACY LATCH, LEVER HANDLE PRIVACY LATCH, LEVER HANDLE NOTES NOTES DOOR UNDERCUT, REFER MECHANICAL ENGINEERS DOCUMENTATION FOR VENTILATION REQUIREMENTS -/60/30sm FRR -/120/120 FRR smoke control only f ir e d o o r n o t e s SINGLE FIRE DOORS SHALL BE -/60/30sm CERTIFIED FIRE DOORS COMPLETE WITH; -/60/30sm FRR 1,200 810 810 1,405 650 DOOR CLOSER 650 DOOR NO. D1.1, D2.2 TENANCY 1, TENANCY 2, TENANCY 3 LOCATION TENANCY 2 LOBBY, TENANCY 3 LOBBY TENANCY 2 LOBBY MORTICE LATCH. ANY LOCKING SYSTEM SHALL NOT STOP THE DOOR FROM CLOSING WHEN IN THE ACTIVE POSITION 5. CERTIFICATION LABELS 6. FIRE DOOR SIGNAGE ON BOTH SIDES OF THE DOOR STATING ‘FIRE DOOR. PLEASE KEEP CLOSED.’ THESE SHALL BE SMALL GREEN STICKERS WITH WHITE LETTERING. 7. EGRESS DOORS ARE SHALL HAVE 760mm MINIMUM CLEAR OPENING (2 OFF) D1.2 FRAME 50mm GALVANISED STEEL SECTION WINDOW FRAME FRAME PACIFIC VP60-P HINGED DOORSET WITH SIDELIGHT REVEALS 25mm GROOVED FOR LININGS REVEALS REVEALS DOOR - GLAZING (1 OFF) TENANCY 2 LOBBY TIMBER FRAME HINGED DOORSET WITH SIDELIGHT PACIFIC VP60-P HINGED DOORSET FRAME VANTAGE 40mm SERIES ALUMINIUM FRAME 42mm SELECTED TIMBER FRAME WITH PROFILE 'B' GROOVED FOR LININGS REVEAL AND 30x20mm PLANTED STOP 42mm TIMBER FRAME WITH PROFILE 'B' GROOVED FOR LININGS REVEAL AND 30x20mm PLANTED STOP 42mm TIMBER FRAME WITH PROFILE 'B' GROOVED FOR LININGS REVEAL AND 30x20mm PLANTED STOP REVEALS 25mm GROOVED FOR LININGS REVEALS DOOR 48mm THICK SOLID CORE TIMBER DOOR STILES WITH SELECTED TIMBER VENEER 48mm THICK SOLID CORE TIMBER DOOR STILES WITH SELECTED TIMBER VENEER 50mm THICK SOLID CORE TIMBER DOOR LEAF FOR PAINT FINISH DOOR - 40mm THICK SGG CONTRAFLAM GLASS WITH GALVANISED STEEL GLAZING BEADS GLAZING PYROBEL 16 GLAZING WITH ALUMINIUM ANGLE GLAZING BEAD TOUGHENED SAFETY GLASS WITH ALUMINIUM ANGLE GLAZING BEAD - GLAZING CLEAR LAMINATED SINGLE GLAZED SAFETY GLASS TO COMPLY WITH NZS:4223 FINISH POWDER COATED STEEL FRAMES WITH PAINT FINISH REVEALS FINISH SELECTED TIMBER VENEER DOOR FOR CLEAR FINISH, SELECTED TIMBER REVEAL FOR CLEAR FINISH SELECTED TIMBER VENEER DOOR FOR CLEAR FINISH, SELECTED TIMBER REVEAL FOR CLEAR FINISH PAINT FINISH FINISH POWDER COATED ALUMINIUM FRAMES WITH PAINT FINISH REVEALS HARDWARE INTUMESCENT SMOKE SEALS TO FRAME HARDWARE DOOR CLOSER, CERTIFICATION LABELS, FIRE DOOR SIGNAGE SMOKE SEALS, DOOR CLOSER, SMOKE CONTROL SIGNAGE LATCH & LOCKSET, REBATE KITSET, LEVER HANDLE, FLUSH BOLT, DUST SOCKET, DOOR CLOSERS HARDWARE INTUMESCENT SMOKE SEALS TO FRAME NOTES REFER FIRE REPORT NOTES REFER FIRE REPORT REFER FIRE REPORT REFER FIRE REPORT NOTES D0.4 (1 OFF) NORTH WALL FIRE WINDOWS SHALL BE -/120/120 CERTIFIED FIRE WINDOW SYSTEMS REFER 'TM CONSULTANTS' FIRE ENGINEER FOR FIRE RATED DOOR AND WINDOW SYSTEMS LOCATION PRELIMINARY PRINT | 14/11/13 | 3:45 PM 4. THE PANEL JOIN SEALANT USED IN THESE WALLS SHALL BE CERTIFIED TO PROVIDE NO LESS THAN A TWO WAY 120 MINUTE FIRE RESISTANCE RATING. fixed STORE LOCATION DOOR CLOSER 1. W1.8 (3 OFF) 3. f ir e w i n d o w n o t e s WINDOW NO. W0.1, W1.4, W2.5 REBATED INTUMESCENT SMOKE SEALS TO THE TWO VERTICAL EDGES AND TOP EDGE OF THE DOOR FRAME THESE WINDOWS SHALL NOT BE OPENABLE HARDWOOD TIMBER ARCHTRAVE OVER 13mm PLASTERBOARD BETWEEN FRAMES WINDOW NO. 2. REFER 'TM CONSULTANTS' FIRE ENGINEER FOR FIRE RATED DOOR AND WINDOW SYSTEMS 150 1,000 45 1,900 1,945 170 1,630 HEIGHT TO MATCH FIRE DOOR ADJACENT 0.52 m2 1,000 1,960 HEIGHT TO MATCH FIRE DOOR ADJACENT 2,200 1,630 1,960 MAX HEIGHT SIDELIGHT 170 DOOR CLOSERS 970 2,050 320 320 INTERIOR W IND O W S 170 DOOR CLOSER 0.52 m2 CLEAR FIRE RATED GLAZING, WHERE VISION PANEL SPECIFED, (NOT GEORGIAN WIRED) TO HAVE A -/60/- FRR AND HAVE A SIZE NO GREATER THAN 0.065m2 DOOR LEAF 320 320 MAX HEIGHT VISION PANEL 10 A4.3 170 1,000 800 fixed INTERIOR D O O R S FIRE R A TED - T IMBER N E W DOOR S 8 A4.3 2,400 1,600 EXTERIOR W INDOW S FIRE R A TED - ST EEL NE W W INDOW S DOOR LEAF 9 A4.3 NE W W INDOW S 900 1. (1 OFF) A N E W O F F I C E 3 0 7 D U R H A M B U I L D I N G S T R E E T DOOR & WINDOW SCHEDULE 13/11/13 TH 15/03/2013 SL 1:50@A2 1:100@A4 4643 BUILDING CONSENT ISSUE A7.2 A