HPV-02. Variable pumps for closed loop operation.
Transcription
HPV-02. Variable pumps for closed loop operation.
HPV-02. Variable pumps for closed loop operation. y y y y y y y y y 1 control device modular design, precise and loadindependent 2 swash-plate hydrostatic bearing 3 piston-slipper assembly 21° swash angle 4 housing monoshell for high rigidity 5 valve plate housing highly integrated 6 control piston integrated, hydraulically captured 7 through shaft for additional pumps 8 cylinder barrel compact due to 21° technology 9 integrated pressure relief valves for system and charge pressure Design characteristics >>axial piston pump in swashplate design for high pressure closed loop systems >>clockwise or counter clockwise rotation >>exact and rugged servo control devices (mechanical, hydraulic, electro-hydraulic) >>integrated high pressure relief valves with make-up function >>integrated low pressure relief valves for charge, control and cooler circuits >>replaceable cartridge filter >>SAE high pressure ports >>SAE mounting flange with ANSI or SAE spine shaft >>through shaft SAE A, B, B-B, C, D and E >>charge pressure pumps for internal and external suction, integrated cold start relief valve optional >>hydrostatic bearings of the rotating group compensate for axial forces >>optional tandem and multiple pumps Product advantages >>compact design >>high power density >>dynamic response >>high reliability >>long service life >>noise-optimized >>precise and load-independent servo control 2 LinDrive = Precision x Dynamics x Reliability = Benefitn Linde Hydraulics product range Find the right products for your application. Product range Product Pump Motor Valve Technology Electronics Application Linde product name Self-regulating pump open loop operation HPR-02 Variable pump closed loop operation HPV-02 Variable motor closed and open loop operation HMV-02 Regulating motor closed and open loop operation HMR-02 Fixed motor closed and open loop operation HMF-02 open loop operation HMF-02 P closed and open loop operation HMA-02 LSC manifold plate open loop operation VT modular Monoblock open loop operation Monoblock Electronic control unit closed and open loop operation LINC Peripheral equipment closed and open loop operation Software diagnosis and configuration LinDiag® Content HPV-02. The closed loop 4 Dimensions General technical data 5 >> M-controls 26 >> H-controls 27 Operational parameters >> Life time recommendations 6 >> CA-controls 28 >> Filtration 6 >> E-controls 29 >> Pressure fluids and mounting orientation 7 >> Modular system 30 Torque transmission 8 >> HPV-02 tandem pumps 33 >> Mounting flange 9 >> HPV-HPR-02 multiple pumps 34 >> Drive shaft 10 Modular system features 35 >> PTO flange 11 Your notes 35 >> Output shaft 11 Contact 36 Gear pumps 12 Controls 15 >> Control accuracy 16 >> M. Mechanical-hydraulic 17 >> H. Hydraulic 19 >> CA. Hydraulic-mechanical 21 >> E. Electro-hydraulic 22 The data on which this brochure is based correspond to the current state of development. We reserve the right to make changes in case of technical progress. The dimensions and technical data of the individual installation drawings are prevailing. The features listed in this data sheet are not available in all combinations and nominal sizes. Our sales engineers will be happy to provide advice regarding the configuration of your hydraulic system and on product selection. 3 The closed loop. Representation of the hydraulic components of a closed loop hydrostatic drive: Variable electro-hydraulic controlled pump HPV-02 E1 (top view) and fixed displacement motor HMF-02 plus filter, cooler and oil tank. The function diagram and the circuit diagram show two types of cooling. Function diagram Option 2: Cooler in return line Tank Option 1: Cooler in charge circuit External suction HPV-02 R E1 HMF-02 Circuit diagram The boost pump is shown with internal and external suction. Tank Option 2: Cooler in return line Option 1: Cooler in charge circuit External section HMF-02 HPV-02 R E1 Standard Linde name plate Each Linde Hydraulics unit features a name plate showing the type and the serial number. For a single order via 'open variant' a customer-specific number or free text with up to 15 characters can be stamped on the name plate. Type Serial-No. Part No. 4 HPV105-02 Series 02 variable pump, rated size 105 R Right hand rotation 2553 the last 4 figures of the Bill of Material H2X 264 Type number of HPV 105-02 T Letter indicating year of production 12345 Serial number 12345678 Free text field for up to 15 characters General technical data. The table shows the complete capacity range of the pumps, while the diagram below shows the recommended practical range for the different nominal sizes of the HPV-02 pump with control limit between 200 bar ∆pmin and 280 bar ∆pmax . It enables initial selection of the required nominal pump size. Overview of technical data Rated size 55 75 105 135 165 210 280 cc/rev 54.7 75.9 105 135.7 165.6 210.1 281.9 Maximum continuous speed rpm 3300 3100 2900 2700 2500 2300 2000 Maximum speed (intermittent) rpm 3700 3500 3200 2900 2700 2500 2200 Minimum continuous speed rpm 500 Maximum operating pressure bar 420 Max. pressure (intermittent) bar 500 Continuous pressure (∆p) bar 250 Permissible housing pressure bar 2.5 Continuous input torque Nm 218 302 418 540 659 836 1122 Maximum input torque Nm 353 489 677 875 1067 1354 1817 Continuous power kW 75 98 127 153 173 201 235 kW 122 159 206 247 279 326 381 Maximum displacement Speed Pressure absolute at continuous pressure Torque HPV without charge pump at max. op. pressure, 19 bar charge pressure at max. cont. speed, cont. pressure Power Maximum power at max. cont. speed, max. op. pressure, 19 bar charge pressure Permissible shaft loads Permissible housing temperature Axial N 2000 Radial N on request Perm. housing temperature °C 90 HPV-02 kg 46 49 66 72 113 132 164 dm³ 2.1 2.8 3.4 3.8 4.2 4.8 5.5 kgm²x 10-² 0.54 0.84 1.49 2.2 3.11 4.77 9.38 with minimum perm. viscosity > 10 cSt with H1-control without oil (approx.) Weights Filling volume HPV-02 inclusive IGP (size 55-135) or EGP (size 165-280) housing with filter Maximum moment of inertia Recommended operating range of HPV-02 300 250 Antriebsleistung Input[KW] power [kW] HPV 280 200 HPV 210 HPV 165 150 HPV 135 HPV 105 100 HPV 75 HPV 55 50 0 1400 1600 1800 2000 AntriebsdrehzahlInput [U/min] speed 2200 2400 2600 2800 [rpm] 5 Operational parameters. Life time recommendations Linde high pressure units are designed for excellent reliability and long service life. The actual service life of a hydraulic unit is determined by numerous factors. It can be extended significantly through proper maintenance of the hydraulic system and by using high-quality hydraulic fluid. Beneficial conditions for long service life >>Speed lower continuous maximum speed >>Operating pressure less than 300 bar ∆p on average >>Max. pressure only at reduced displacement >>Viscosity 15 ... 30 cSt >>Power continuous power or lower >>Purity of fluid 18/16/13 in ac. with ISO 4406 or better Adverse factors affecting service life >>Speed between continuous maximum speed and intermittent maximum speed >>Operating pressure more than 300 bar ∆p on average >>Viscosity less than 10 cSt >>Power continuous operation close to max. power >>Purity of fluid lower than 18/16/13 in acc. with ISO 4406 Operational parameters. Filtration In order to guarantee long-term proper function and high efficiency of the hydraulic pumps the purity of the pressure fluid must comply with the following criteria according to Linde Works Standard WN 51 210. High purity oil can extend the service time of the hydraulic system significantly. >>For reliable proper function and long service life 18/16/13 in accordance with ISO 4406 or better >>Minimum requirements 20/18/15 in accordance with ISO 4406 >>Commissioning The minimum purity requirement for the hydraulic oil is based on the most sensitive system component. For commissioning we recommend a filtration in order to achieve the required purity. >>Filling and operation of hydraulic systems The required purity of the hydraulic oil must be ensured during filling or topping up. When drums, canisters or large-capacity tanks are used the oil generally has to be filtered. We recommend the implementation of suitable measures (e.g. filters) to ensure that the required minimum purity of the oil is also achieved during operation. >>International standard code number according to ISO 4406 purity class according to SAE AS 4059 18/16/13 corresponds to 8A/7B/7C 20/18/15 9A/8B/8C Filters Units of the HPV-02 series can be equipped with a pure charge pressure manifold or with a combined charge pressure and filter flange manifold. The following filter sizes are available, depending on the rated size of the unit. Further details about the mounting of the charge pressure manifold see section "Dimensions. Modular System". Filter 6 55 Nr. 2 x Nr. 3 x 75 105 135 165 210 280 x x x x x x Operational parameters. Pressure Fluids and mounting orientation In order to ensure the functional performance and high efficiency of the hydraulic pumps the viscosity and purity of the operating fluid should meet the different operational requirements. Linde recommends using only hydraulic fluids which are confirmed by the manufacturer as suitable for use in high pressure hydraulic installations or approved by the original equipment manufacturer. Permitted pressure fluids >>mineral oil HLP to DIN 51 524-2 >>biodegradable fluids in accordance with ISO 15 380 on request >>other pressure fluids on request Linde offers an oil testing service in accordance with VDMA 24 570 and the test apparatus required for in-house testing. Prices available on request. Recommend viscosity ranges Pressure fluid temperature range [°C] -20 to +90 Working viscosity range [mm²/s] = [cSt] 10 to 80 Optimum working viscosity [mm²/s] = [cSt] 15 to 30 Max. viscosity (short time start up) [mm²/s] = [cSt] 1000 In order to be able to select the right hydraulic fluid it is necessary to know the working temperature in the hydraulic circuit. The hydraulic fluid should be selected such that is optimum viscosity is within the working temperature range (see tables). The temperature should not exceed 90 °C in any part of the system. Due to pressure and speed influences the leakage fluid temperature is always higher than the circuit temperature. Please contact Linde if the stated conditions cannot be met in special circumstances. Viscosity recommendations Working temperature [°C] Viscosity class [mm²/s] = [cSt] at 40 °C approx. 30 to 40 22 approx. 40 to 60 32 approx. 60 to 80 46 or 68 Mounting orientation The preferred mounting orientation is generally horizontal. Special pump configurations for vertical mounting with the drive shaft pointing either upward or downward are available for selected rated sizes and have to be requested separately. For further information concerning the installation of the unit please refer to the operating instructions manual. 7 Torque transmission. Depending on the selected components, different torques may be transferred. Please ensure that the load transfer components such as mounting flange, PTO-through shaft and additional pumps are designed adequately. Our sales engineers will be pleased to provide design advice. Torque transmission of HPV-02 This shows the input side (A) und PTO-/output side (B) of a HPV-02 pump. The information on the following pages refers to >> mounting flange and drive shaft (A) >> PTO flange and through shaft (B). A) Flange profile Bolt hole dimensions 55 75 105 135 165 210 280 M1 inside diameter mm 17.5 17.5 17.5 21.5 21.5 22 22 M2 outside diameter mm 34 40 34 40 40 38 39 M3 length mm 20 20 25 20 25 30 30 Bolt hole diameter 8 M2 M1 Bolt hole length Torque transmission. Mounting flange Mounting Mounting flange in accordance with SAE J744 For rated size Washer Screw Dimensions Torque (8.8) Torque K H V G [Nm] (10.9)* [Nm] [mm] [mm] [mm] [mm] SAE C, 2 hole 55, 75, 105 17x33x10 M16 195 275 181.0 - - - SAE C, 2 hole 75 & 105 17x33x10 M16 195 275 181.0 - - 114 SAE D, 2 hole 135 21x37x8 M20 385 540 228.6 - - - SAE D, 2 hole 135 21x37x8 M20 385 540 228.6 - - 138 SAE D 2 hole with additional bolt holes (d=17.5mm) 135 & 165 21x37x8 M20 385 540 228.6 230 190 - SAE E, 4 hole 210 & 280 - M20 385 540 224.5 - - - with 4 additional threads M12 with 4 additional threads M16 *) Option for standard design, necessary for tandem units 2-hole flange 4-hole flange 2-hole flange with 4 additional threaded holes 2-hole flange with 4 additional bolt holes 9 Torque transmission. Drive shaft A) Dimensions ANSI and SAE drive shafts Shaft spline (in accordance with ANSI B92.1) 12/24, 14 t SAE-J744 code (for centring and shaft) Outside diameter [mm] Useable spline length [mm] Shaft type C 31.22 30 34.51 16/32, 21 t 12/24, 17 t C-C 16/32, 23 t 8/16, 13 t D, E 16/32, 27 t 8/16, 15 t F 16/32, 33 t Available for rated size 55 75 105 135 165 2 x x x 39.5 1 x* x* 37.68 30 2 x 37.68 38.5 1 x* 43.71 50 2 x x 44.05 62 1 x x* 50.06 58 1 53.57 58 1 210 280 x x x* x x* *) Recommended for tandem configurations A) Maximum input torque Rated size Shaft 55 75 105 135 165 210 280 16/32 21 t 16/32 21 t 16/32 23 t 16/32 27 t 16/32 27 t 8/16 15 t 16/32 33 t Continuous torque Nm 435 604 836 1080 1318 1672 2243 Maximum torque Nm 649 900 1245 1609 1964 2491 3343 Excess length mm 54 55 55 75 75 75 75 A) Linde Hydraulics shaft types Type 1. Without undercut Outside diamter Outside diameter Type 2. With undercut Usable spline length Excess length 10 Usable spline length Excess length Torque transmission. PTO flange Linde pumps can be combined into tandem and multiple pumps. The combination options are determined by the permitted transfer torque. The following data refers to the PTO (pump output side, without further attachments). B) PTO dimensions Rated size Z Drive hub profile in accordance with ANSI B92.1 55 75 105 135 165 210 280 16/32, 15 t 16/32, 18 t 16/32, 19 t 16/32, 21 t 16/32, 22 t 16/32, 24 t 16/32, 27 t 40 42 48 52 63 63 72 D1 mm D2 spigot pilot diameter mm D3 mm D4 mm D5 max. bearing clearance mm L1 mm 1.5 L2 adapter length mm 7 L3 mm L4 minimum distance mm 35 39 33 35 37 38.5 50.5 L5 usable spline length mm 14 18 19 20 25 29 30.6 L6 distance to bearing mm 51 57.5 53 55.9 63.1 68.3 83 L7 min. bearing clearance mm 3 3 3 4 3 3 - L8 hole distance 2-hole mm 82.55 88 89.5 89.5 M 10 30 35 38 M12 43 44.5 47 49 1.9 8 9 106.4 146 B) Output shaft transfer torque Rated size 55 75 105 135 165 210 280 Continuous transfer torque Nm 218 302 418 540 659 836 1122 Max. transfer torque Nm 431 598 763 1069 1305 1655 2221 Torque transmission. Output shaft B) PTO dimensions Drive hub profile Z 11 Gear pumps. Two types of gear pumps are available: internal gear pump IGP and external gear pump EGP. The possible combinations of and with IGP and EGP are determined by the PTO option and the permitted shaft torque. Both types can be used as charge pump for the main circuit or the control and cooling circuit. The allowable pressure at the suction port is between 0.8 bar (abs.) and 3.0 bar (abs.). The charge pressure relief valves for the rated sizes 55-135 are integrated in the port plate housing, and for the rated sizes 165-280 in the charge pressure manifold of the HPV-02. Technical data Displacement volume cc/rev 16 Standard charge pump for HPV-02 Rated size 55-105 Type of gear pump 22.5 31 38 44 75-135 165 210 280 IGP EGP IGP EGP EGP EGP Mounting flange and drive shaft profile SAE A 16/32, 18 t SAE A 16/32, 9t SAE A 16/32, 18 t SAE A 16/32, 9t SAE A 16/32, 13 t SAE A 16/32, 13 t Type of suction internal, external external internal, external external external external 40 210 40 165 275 220 SAE A 16/32, 9t - SAE A 16/32, 9t - - - 175 - 75 Nm with SAE A 175 - - - Max. perm. operating pressure observe max. permissible rated pressures for filter and cooler bar Standard PTO flange and shaft spline Continuous output torque Nm 75 Nm with SAE A Max. output torque Nm 107 Nm with SAE A 250 - 107 Nm with SAE A 250 - - - integrated - integrated - - - Cold start relief valve External gear pump EGP 12 19 Gear pumps. The IGP charge pumps include a cold start relief valve and a through drive for attaching additional pumps. The suction can be internal, external or combined. IGP types are available in rated sizes of 16 cc/rev and 22.5 cc/rev. Internal gear pump IGP with internal suction Internal suction A HPV-02 Combined suction External suction A HPV-02 A HPV-02 B B >>Internal suction The charge pump supplies the main circuit with oil from the pump housing. External connection B is closed. >>External suction The charge pump supplies the main circuit with oil from the oil tank. Ther internal connection is closed. >>Combined suction The charge pump supplies the main circuit with oil from the pump housing and oil tank. This type of suction is a combination of internal and external suction. 13 Gear pumps. PTO flange with IGP Flange profile 2-hole Z Internal drive hub profile in accordance with ANSI B92.1 SAE A SAE B SAE B-B SAE C 16/32, 9 t 16/32, 13 t 16/32, 15 t 12/24, 14 t D1 Spigot pilot diameter mm 82.55 101.6 127 D2 Thread size mm M 10 M 12 M 16 L1 Hole distance mm 106.4 146 181 L2 Adapter length mm 7 11 13 L3 Flange length mm - 55 72 Continuous transfer torque Nm 75 175 Maximum transfer torque Nm 107 250 PTO SAE A with IGP PTO SAE B, B-B and C with IGP Drive hub profile Z Drive hub profile Z 14 Controls. The modular control concept with standardised interface enables quick selection and adaptation for different customer and system requirements with mechanical, hydraulic or electronic control. All Series 02-controls feature an upstream signal circuit that is adapted to the respective control, and a standardised and load-independent servo control for simple and constantly available machine or vehicle control. Technical data Type of control Additional option Mechanical proportional M1R Hydraulic proportional H1 with pressure cut-off regulation H1P speed dependent CA torque-/power controlled CA with additional safety function CA proportional E1 with pressure cut-off regulation E1P with additional safety function E2 3 position E5 Electrical Name of control E1/E5-control E1P-control E2-control H1-control H1P-control CA-control M1R-control HPV-02 E2 15 Controls. Control accuracy All Series 02-pump controls result in the same machine response for identical motion commands, irrespective of the control type. Corrective action by the operator is no longer required. The reliable control of the pump can easily be integrated into any kind of vehicle management control system. Control accuracy of a HPV-02 pump E2-control Swash angle pump 100 % - 100 % - min min - 100 % Pressure cut-off regulation PCO 100 % Input signal y 1 Setting the maximum displacement Special control elements deal with functions such as torque control or pressure cut-off regulation. Controls with pressure cut-off regulation (PCO) reduce pump flow when the cut-off pressure is reached. Because system pressure is maintained at low flow, the power consumption and thermal balance of the system are optimised. Displacement relative to pilot pressure and pressure cut-off regulation for H- and E-controls PCO HP valve Pre-loading valve Min 16 100 Displacement [%] Pilot pressure ∆p Y/Z [bar] Max Regulation begin 0 PCO Regulation end 0 High pressure [bar] Max Controls. Mechanical-hydraulic M The M1R-pump control combines robustness with high precision for direct and reliable machine control. It is mechanically controlled and can be combined with a fixed, variable or regulating hydraulic motor. The control-specific data is independent of the nominal pump size. M1R Mechanical control Flow direction By turning the control lever the pump flow rate and direction of flow are controlled via a cam plate. The flow direction of the fluid depends on >>the pump direction of rotation >>the over centre direction of the swash plate. High pressure outlet port Shaft rotation (view on Z) Cam lever direction P, S A B F X Ms, Mp L, U L1, L2 High pressure ports Pressure port, charge pump Suction port, charge pump Feed port, charge and control Test port, control pressure Test ports, high pressure Drain ports Vent ports Right hand Left hand Note for left hand rotation A Suction port, charge pump B Pressure port, charge pump 17 Controls. Mechanical-hydraulic M The cam plate offers a large control angle with progressive control characteristic and a wide neutral range. The resulting high resolution for movements from the neutral range (and vice versa) enables precise manoeuvring. Reliable and robust control of the displacement volume is achieved through position feedback. Displacement [%] Displacement relative to control angle Control angle [%] Control force with max. long lever radius r= 70 mm 17 N Max. permissible control force (intermittent) 500 N Control torque < 1.0 Nm Control torque out of notch < 1.5 Nm Neutral position 24°, 90° (standard), 133°, 144°, 188°, 210°, 232° Control angle neutral range ... to end position ±3° ... ±48° Minimum response time with standard restrictors 0.5 s M1R-cam plate Control range neutral dwell angle + / - 3° neutral = 90° reference axis for neutral position 18 Controls. Hydraulic H The HPV-02 H1 features hydraulic control with a wide pilot pressure range for improved machine control. It can be combined with a fixed, variable or regulating hydraulic motor. The data is specific for hydraulic controls, and independent of the nominal pump size and pressure cut-off regulation PCO, unless specified otherwise otherwise (see section Controls. Control accuracy). H1. Hydraulic control Flow direction By an external hydraulic signal input at the pilot pressure ports (Y, Z) the pump flow rate and direction of flow are controlled. The flow direction of the fluid depends on the pump direction of rotation and the over centre direction of the swash plate. High pressure outlet port Shaft rotation (view on Z) Pilot pressure port H1P. Hydraulic control with PCO Right hand Left hand Y P S Z S P P, S High pressure ports A Pressure port, charge pump B Suction port, charge pump F Feed port, charge and control X Test port, pilot pressure Ms, Mp Test ports, high pressure L, U Drain ports T Vent port Y, Z Pilot pressure ports Note for left hand rotation A Suction port, charge pump B Pressure port, charge pump 19 Controls. Hydraulic H Pilot pressure range standard: 4-16 bar, option: 4-10 bar differential pressure |Y-Z| Maximum permissible pressure at Y or Z 30 bar Minimum response time with standard orifices for one-way swashing between 0 and max 0.5 s Displacement relative to pilot pressure 100 Displacement [%] 80 60 Standard: 4 - 16 bar Option: 4 - 10 bar 40 20 0 2 H1P-control with PCO 20 4 6 8 10 Pilot pressure ∆p = IY-ZI [bar] 12 14 16 18 Controls. Hydraulic-mechanical CA The HPV-02 CA is a speed-dependent pump control with torque/power regulation. It can be combined with a hydraulic motor as fixed, variable or regulating motor or a variable motor with pressure regulator. The modular design offers a high degree of versatility in terms of function and control. CA. Hydraulic-mechanical control CA-control. Advantages P, S High pressure ports A Suction port, charge pump F Feed port, charge and control Test ports >>pilot operated system >> controlled load response >> temperature independent >> dynamics >> precision >> low hysteresis >> high versatility (modular design) >> various motor control possible Mt Temperature Ms, Mp High pressure Y, Z Pilot pressure Ml For power settings and inch pressure port Msp Charge pressure X Pilot pressure port HMV L, U Drain ports L1, L2 Vent ports T Drain and vent port Note for left hand rotation A Suction port, charge pump >>simple adjusting >>direct control of torque and tractive force >>speed optimized inching function >>high safety standard >> hydrostatic deceleration Drive with speed-dependent variable pump and variable motor with pressure override HPV-02 CA HMV-02 EH1P Inching pedal Brake Not every component shown is part of the Linde product portfolio. 21 Controls. Electro-hydraulic E1 and E5 The HPV-02 E1 has two proportional solenoids and through the upstream signal circuit it combines the flexibility of electronic vehicle management with the reliability of a pump control marked by its high operational availability. Precise and simple. Identical commands always call for the same response in the machine, so no corrective action is required by the operator or the electronic system. The HPV-02 E5 has two switching solenoids and thus sets the pump to either neutral or maximum swash angle of any direction. E1. Electro-hydraulic control E1P. Electro-hydraulic control with PCO E5. Electro-hydraulic 3 position control P, S High pressure ports A Pressure port, charge pump B Suction port, charge pump F Feed port, charge and control X Test port, pilot pressure Ms, Mp Test ports, high pressure L, U Drain ports T Vent ports Note for left hand rotation A Suction port, charge pump B Pressure port, charge pump 22 Controls. Electro-hydraulic E2 Verstellungen. Elektro-hydraulisch E2 The HPV-02 E2, with its additional release function, can easily be integrated in an electronic vehicle management control system like an E1-control. In addition it offers a safety standard that meets the stringent requirements for road traffic use. The E2-control features two proportional solenoids and a switching solenoid. Die HPV-02 E2 ist mit ihrer zusätzlichen Freigabefunktion ebenso einfach in ein elektronisches Fahrzeugmanagement integrierbar wie mit einer E1-Verstellung. Darüber hinaus bietet sie den für eine Straßenzulassung erforderlichen hohen Sicherheitsstandard. Die E2-Verstellung hat zur Ansteuerung zwei Regelmagnete und einen Schaltmagneten. E2. Verstellung E2. Elektro-hydraulische Electro-hydraulic control Durchflussrichtung E2 with switch-off function Product advantages of E2 Über ein externes elektrisches Eingangssignal an den Magneten (MY und MZ) werden Volumenstrom und Richtung des The E2 control offers gesteuert. an interface switching off thedes whole Pumpenförderstroms Diefor Durchflussrichtung Öls ist abhängig >>fulfilsvon the rigorous demands for road traffic use system. In case of signal irregularity or perturbation like cable >> der Antriebsdrehrichtung der Pumpe und >>active drive enable break or short-circuit in the switching solenoid circuit (co called >> der Schwenkrichtung der Wiege. >>minimized susceptibility to interference 'watchdog'), the pump swashes back to neutral position in a >>with HMF-02: defined swashing back of pump for controldefined manner. Anschluss des Ölaustritts (siehe Kapitel Verstellungen. Elektro-hydraulisch E1) led deceleration and stop in case of system fault The vehicle is decelerated until standstill and thus provides a safe condition of the machine as per EN ISO 13849. In case of disfunction in the proportional magnets' circuits, a E2 mit Sicherheitsfunktion similar reaction can be induced by the intervention of the elecDie elektronische Steuereinheit vergleicht den Fahrbefehl mit tronic control units. anderen Maschinensignalen. Bei Abweichung (z.B. bei Its use is recommended for mobile applications where specific Stromausfall durch Kabelbruch oder Kurzschluss) deaktiviert die safety criteria have to be met in terms of travel and coasting elektronische Steuereinheit den Freigabemagneten an der behaviour, e.g. road traffic use. E2-Verstellung und die Pumpe wird aktiv und kontrolliert zurückgeschwenkt. Dadurch wird das Fahrzeug gezielt bis zum Maschinenstillstand gebremst – ohne den Fahrer zu gefährden. Der Einsatz empfiehlt sich bei Fahrantrieben mit besonderen Sicherheitsanforderungen hinsichtlich des Fahr- und Ausrollverhaltens, z.B. bei Straßenfahrt. >>with HMV-02: diesel overspeed protection by fast swashing back of pumpE2 Produktvorteile entspricht den hohen Anforderungen der Strassenzulassung >> >> aktive Fahrtfreigabe >> P, S minimierte High Störanfälligkeit pressure ports A kontrollierte Pressure port, chargeund pump >> Verzögerung Stillstand bei evtl. B Systemstörung Suction port, charge pump F Feed port, charge and control X Test port, control pressure P, S Hochdruckanschlüsse Ms, Mp Test ports, high pressure A Druckanschluss Speisepumpe Y, Z Test ports, control pressure B Sauganschluss Speisepumpe L, U Drain ports F Steuerdruckversorgung T Vent port X Messanschluss Steuerdruck Ms, NoteMp for leftMessanschlüsse hand rotation Hochdruck Y, A Z L, B U T Messanschlüsse Suction port, chargeSteuerdruckanschluss pump Leckölanschlüsse Pressure port, charge pump Entlüftungsanschluss Anmerkung für Linkslauf A Sauganschluss Speisepumpe B Druckanschluss Speisepumpe 23 Controls. Electro-hydraulic E E1 control E1P control E5 control E2 control Flow direction By an external electrical signal input at the solenoids (MY and MZ) the pump flow rate and direction of flow are controlled. The flow direction of the fluid depends on >>the pump direction of rotation >>the over centre direction of the swash plate. High pressure outlet port Shaft rotation (view on Z) Active solenoid 24 Right hand Left hand MY P S MZ S P Controls. Electro-hydraulic E The data is specific for electrical controls, and independent of the nominal pump size and PCO pressure cut-off regulation, unless specified otherwise (see section Controls. Control accuracy). Figures HPV-02 E1 and HPV-02 E2 (page 22, 23) show the standard mounting position for the respective E-control. Control signal characteristics Supply voltage = limiting voltage V 12 24 DIN EN 175301-803, Deutsch, AMP Junior Timer (2-pin*) Connector type Voltage type Direct Current (D.C.) Power consumption W Rated current = limiting current mA 1300 650 mA 450 ± 10 225 ± 5 pilot pressure range 4-10 bar (option) mA 810 410 pilot pressure range 4-16 bar (standard) mA 1200 600 swash begin Control current swash end on request Relative duty cycle 15.6 % Protection class 100 IP54 (DIN), IP67 (Deutsch), IP6K6K (AMP) digital control via Pulse Width Modulation PWM 100 Hz rectangle, pulse duty ratio variable over control range analogue control Direct current with dither overlay (dither frequency nom. 35 Hz, duty cycle 1:1). Further details on request Control types Minimum response time with standard orifices s 0.5 *) Coding 1 with proportional solenoids (E1, E1P), coding 2 with switching solenoids (E2, E5) Displacement relative to control current 24 Volt (4-16 bar) Displacement [%] 24 Volt (4-10 bar) 12 Volt (4-10 bar) 12 Volt (4-16 bar) Control current [mA] 25 Dimensions. M-controls Control-specific dimensions for HPV-02 with mechanical-hydraulic controls. Port sizes and dimensions for M-controls Rated size D1 [mm] B1 [mm] B2 [mm] B3 [mm] B4 [mm] B5 [mm] L1 [mm] L2 [mm] L3 [mm] L4 [mm] L5 [mm] L6 [mm] H1 [mm] H2 [mm] H3 [mm] P S A gear pump B gear pump L U F X Mp Ms L1 L2 55 75 127 181 101 101 192 105 116 116 216 242 304 359 267 329 385 88 95 184 SAE ¾“ SAE ¾“ 93 103 188 99 105 193 SAE 1“ SAE 1“ M27x2 M36x2 M22x1.5 M22x1.5 M22x1.5 Threads metric in accordance with ISO 6149-1 Suction port at IGP in accordance with ISO 8434-1 L28 High pressure ports similar to ISO 6162-2 Socket cap screw in accordance with ISO 4762 26 165 152.4 228.6 225 282 335 Further threads on request 135 141 141 141 138.5 219 233 194 288 319.5 350 485.5 425 560.4 151 70 48 106 119.5 112 122.5 198 214.5 SAE 1 ¼“ SAE 1 ¼“ SAE 1“ SAE 1 ¼“ M27x2 M27x2 M14x1.5 M14x1.5 M14x1.5 M22x1.5 M22x1.5 210 280 165.1 224 142 135 240 225 155 246 346 516 591 392 571 646 134 152 133 150 226 238 SAE 1 ½“ SAE 1 ½“ SAE ¾“ SAE 1 ¼“ M27x2 M33x2 M27x2 M33x2 M27x2 Dimensions. H-controls Maße. H-Verstellungen Control-specific dimensions controls. Verstellungsspezifische MaßeforfürHPV-02 HPV-02with mit hydraulic hydraulischen Verstellungen. Anschlüsse unddimensions Maße für H-Verstellungen Port sizes and for H-controls mit MDR PF ST AX Zahnradpumpe BMp Zahnradpumpe LMs UY FZ 5555 165 280 165 210 152.4 165.1 38 44 22,5 16 228.6 224 225 101 2-Loch Anschlussbild 116 141 134.5 4-Loch 143 Anschlussbild 155 101 141D 134.5 135 139 SAE C 116 SAE SAE E 192 216 219 233 240 246 16 / 32 Teilung Verzahnung 16 / 32 231 21 Zähne 23 Zähne 27 Zähne Zähne Zähne 33392 225 242 267 288 319.5 27346 152,4 127 282 304 329 350 485.5 516 165,1 571 228,6 181 225 224 335 359 385 425 560.4 591 646 101 116 141 155 143 133 101 116 141 139 135 88 93 99 106 119.5 134 152 192 216 219 246 240 95 103 105 112 122.5 133 150 231 194 154 158 163 187 191 231 204 267 242 225 288 392 346 185 190 194 199 223 201 214 329 304 282 350 571 516 SAE ¾“ SAE 1“ SAE 1 ¼“ SAE 1 ½“ 385 359 335 425 646 591 SAE ¾“ SAE 1“ SAE 1 ¼“ SAE 1 ½“ 133 133 M27x2 SAE 1“ SAE ¾“ 152 134 106 99 88 93 M36x2 SAE 1 ¼“ SAE 1 ¼“ 150 112 105 95 103 133 M22x1.5 M27x2 M33x2 163 158 194 154 204 191 M22x1.5 M27x2 M33x2 199 194 185 190 201 214 M22x1.5 M27x2 SAE 1 1M27x2 1/4“ / SAE 1 SAE 3/4“ SAE 1“ 2“ M22x1.5 1/4“ 1 SAE 3/4“ SAE 1 / SAE 1 SAE 1“ 2“ M14x1.5 3 SAE /4“ M27x2 M14x1.5 SAE 1 1/4“ M27x2 M14x1.5 M27x2 M22x1,5 M33x2 M14x1.5 M27x2 M33x2 M22x1,5 M14x1.5 M27x2 M27x2 M22x1,5 T X Mp Ms Y Z 7575 127 181 105 105 135 135 in Entwicklung Rated size Nenngröße D1 [mm] Zahnradpumpen B1 [mm] [cm³] Nenngröße B2 [mm] FB3 Flanschprofil [mm] B4 [mm] W Wellenprofil B5 [mm] nach ANSI B92.1 L1 [mm] D1 [mm] L2 [mm] B1 [mm] L3 [mm] B2 [mm] L4 [mm] B3 [mm] H1 [mm] B4 [mm] H2 [mm] B5 [mm] w/o PCO L1 H3 [mm] with PCO L2 [mm] P L3 [mm] S L4 [mm] A gear pump H1 [mm] B gear pump H2 [mm] L ohne MDR H3 U [mm] M22x1,5 M14x1,5 M14x1,5 M14x1,5 M14x1,5 M14x1,5 M22x1,5 M14x1,5 M14x1,5 M14x1,5 M14x1,5 M14x1,5 Anschlussgewinde metrisch nach ISO 6149 Befestigungsgewinde an den SAE Hochdruckanschlüssen metrisch nach ISO 261 Zylinderschrauben nach ISO 4762 Wellenprofil W Flanschprofil F Weitere Gewinde auf Anfrage Threads metric in accordance with ISO 6149-1 Suction port at IGP in accordance with ISO 8434-1 L28 High pressure ports similar to ISO 6162-2 Socket cap screw in accordance with ISO 4762 Further threads on request 26 27 Dimensions. CA-controls Control-specific dimensions for HPV-02 with hydraulic-mechanical controls. Port sizes and dimensions for CA-controls Rated size 55 D1 [mm] 75 105 127 B1 [mm] 152.4 181 B2 [mm] 101 B3 [mm] 101 B4 [mm] 193 228.6 116 141 116 141 212 B5 [mm] 214 217 336 L1 [mm] 225 242 267 288 L2 [mm] 282 306 331 351.5 L3 [mm] 343 361 386.3 426.1 99 105.5 L4 [mm] 207 H1 [mm] 88 93 H2 [mm] 95 103 99 104 H3 [mm] 178 184 187.8 191.1 A gear pump M36x2 P SAE 1“ S SAE 1“ L M22x1.5 U M22x1.5 F M22x1.5 T M22x1.5 X1 M14x1.5 Mp M14x1.5 Ml M14x1.5 Ms M14x1.5 Msp M14x1.5 Mt M14x1.5 Y M14x1.5 Z M14x1.5 Threads metric in accordance with DIN 3852-1 Suction port at IGP in accordance with ISO 8434-1 L28 High pressure ports similar to ISO 6162-2 Socket cap screw in accordance with ISO 4762 Further threads on request 28 135 Dimensions. E-controls Control-specific dimensions for HPV-02 with electro-hydraulic controls. Port sizes and dimensions for E-controls Rated size D1 [mm] B1 [mm] B2 [mm] B3 [mm] B4 [mm] B5 [mm] E1 B5 [mm] E2 L1 [mm] L2 [mm] L3 [mm] L4 [mm] H1 [mm] H2 [mm] 55 75 127 181 105 135 165 210 280 225 282 335 242 304 359 267 329 385 88 95 93 103 99 105 152.4 228.6 141 134.5 141 134.5 219 233 226 230 288 319.5 350 485.5 425 560.4 183 106 119.5 112 122.5 H4 [mm] E1 / E2 159 164 168 173 189.5 218 231 H4 [mm] E1 195 200 204 209 225.5 254 (267) P S Mp Ms A gear pump B gear pump L U F T X Y Z F2 SAE ¾“ SAE ¾“ AMP-JT connectors DIN connectors 101 101 192 116 116 216 SAE 1“ SAE 1“ M27x2 M36x2 M22x1.5 M22x1.5 M22x1.5 SAE 1 ¼“ SAE 1 ¼“ M14x1.5 M14x1.5 SAE 1“ SAE 1 ¼“ M27x2 M27x2 165.1 224 143 135 240 225 155 139 246 346 516 591 392 571 646 134 133 152 150 SAE 1 ½“ SAE 1 ½“ SAE ¾“ SAE 1 ¼“ M33x2 M33x2 M27x2 M22x1.5 M14x1.5 M14x1.5 M14x1.5 M14x1.5 Threads metric in accordance with ISO 6149-1 Suction port at IGP in accordance with ISO 8434-1 L28 High pressure ports similar to ISO 6162-2 Socket cap screw in accordance with ISO 4762 Further threads on request 29 Dimensions. Modular system The following diagrams show the proportions of similar components. Gear pump IGP 16 cc/rev without cover Gear pump IGP 22.5 cc/rev with cover Filter arrangement right (PTO view) for size 55 - 105 (filter no.3) (filter no.2) PTO view >>M1R-control >>IGP 16 cc/rev without cover >>IGP 22.5 cc/rev with cover >>filter mounting side for rated sizes 55 - 105 AMP-JT-connector standard mounting position for E2-control Release solenoid for E2-control AMP-JT-connector mounting position turned by 90° for E2-control DIN-connector mounting position turned by 90° for E1-control E-control DIN-connector standard mounting position for E1-control Charge pressure manifold for HPV 165-02 - 280-02 PTO-through drive SAE A Manual override for DIN-connector Filter flange for HPV 165-02 - 280-02 Gear pump EGP Filter arr. left (PTO view) for size 135 - 280 PTO view 30 >>E1-control with mounting postition of solenoid connectors >>filter mounting side for rated size 135 - 280 >>E2-control with mounting postition of solenoid connectors >>charge pressure manifold for rated size 210 and 280 >>manual override >>DIN-connector >>SAE A PTO-mounting flange >>AMP-JT-connector >>EGP without filter Dimensions. Modular system The following diagrams show the proportions of similar components. H1-control charge flow inlet flange 90° 4-hole mounting flange 2-hole mounting flange mounting flange view >>4-hole mounting flange >>H1-control >>2-hole mounting flange >>filter flange 90° without filter Lever offset version Lever straight version (IZP 22,5 cc/rev) (IZP 16 cc/rev) Companion flange (filt er n o.2 (filt ) er n o.3 ) (filt er n o.2 ) (filt er n o.3 ) (EGP 31 cc/rev) (EGP 38 cc/rev) (EGP 44 cc/rev) side view (size 55 -105) >>M1R-control lever geometry >>IGP >>EGP >>filter >>companion flange 31 Dimensions. Modular system The following data enable quick calculation of the overall maximum external dimensions. In each case only the relevant dimensions are shown so that length, width and height can simply be determined through addition. The actual fitting dimensions of the respective units are shown on the installation drawing. External dimensions for addition y 1 y 2 y 3 y y y 4 5 6 55 Type Length 230 Width 210 Height 185 75 245 235 190 105 270 235 210 135 290 280 220 165 320 270 245 210 350 290 275 280 395 315 305 M1R - 10 95 H1 - 5 55 H1P - 10 75 CA - 135 95 E1/E5 - 5 110 E1P - 10 110 Component Basic unit Control E2 Gear pump Filter - 15 110 16 cc 60 - - 22,5 cc 65 - - 31 cc 135 - - 38 cc 175 - - 44 cc 180 - - 10 without gear pump 95 - 105 - 15 50 - 75 - - Nr.2 Nr.3 F-port 90° Companion flange not shown Intermediate flange Shown in section <<Dimensions. Tandem pumps>> 55 -> SAE C 47.5 75 -> SAE C 47.5 105 -> SAE C 135 -> SAE D / C 165 -> SAE D / C 61.5 / 26 210 -> SAE E / D / C 55 / 68 / 32 280 -> SAE E / D / C 39 / 39 / 45.5 Example: HPV 135-02 H1 with IGP 22.5, filter no. 3 and companion flange 32 37.5 50 / 31 L. 440 mm B. 390 mm H. 275 mm Dimensions. HPV-02 tandem pumps Tandem pumps are created by connecting individual HPV units in series, with the pumps arranged by capacity. Positioning the charge pump(s) at the end of the tandem ensures optimum space utilisation, output allocation and load distribution. 6 p front pum L1 rear pump L2 L3 Overall length of tandem pump Rated size Rear pump HPV 55 HPV 75 HPV 105 HPV 135 HPV 165 HPV 210 HPV 280 Front pump Lengths [mm] L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 496 553 607 513 575 631 529 591 647 543 605 680 571 746 820 610 782 857 655 834 909 530 592 648 546 608 663 560 622 696 588 763 837 627 799 874 672 851 925 572 634 586 586 648 722 613 788 865 653 825 900 698 877 951 640 702 777 670 844 919 702 874 947 723 903 978 684 859 934 722 897 971 755 935 1009 731 903 978 777 956 1030 823 1002 1076 HPV 55 with IGP 16 cc at rear pump HPV 75 with IGP 22,5 cc at rear pump HPV 105 with IGP 22.5 cc at rear pump HPV 135 with IGP 22.5 cc at rear pump HPV 165 with EGP 38 cc at rear pump HPV 210 with EGP 38 cc at rear pump HPV 280 with EGP 44 cc at rear pump 33 Dimensions. HPV-HPR-02 multiple pumps Multiple pumps are created by combining individual pump units in series, with the pumps arranged by capacity. Positioning the gear pump(s) at the end of the unit ensures optimum space utilization, output allocation and load distribution. The following table is based on the gear pump acting as charge pump for the HPV-02 variable pump. p front pum L1 rear pump L2 L3 Overall length of multiple pump Rated size Rear pump Front pump Lengths [mm] HPV 55 with IGP 16 cc at HPR HPV 75 with IGP 22.5 cc at HPR HPV 105 with IGP 22.5 cc at HPR HPV 135 with IGP 22.5 cc at HPR HPV 165 with EGP 38.5 cc at HPR HPV 210 with EGP 38.5 cc at HPR HPV 280 with EGP 44 cc at HPR 34 HPR 55 HPR 75 HPR 105 HPR 135 HPR 165 HPR 210 HPR 280 L1 492 - - - - - - L2 549 - - - - - - L3 603 - - - - - - L1 509 521 - - - - - L2 586 598 - - - - - L3 642 653 - - - - - L1 525 536 567 - - - - L2 602 613 629 - - - - L3 657 669 684 - - - - L1 539 550 581 637 - - - L2 616 627 643 699 - - - L3 690 702 717 774 - - - L1 565 578 608 667 715 - - L2 741 753 783 842 882 - - L3 815 827 857 916 956 - - L1 606 618 648 699 722 733 - L2 793 805 820 871 897 905 - L3 868 879 895 945 972 980 - L1 651 663 693 720 768 779 834 L2 845 856 872 900 948 958 1014 L3 919 931 946 975 1023 1033 1089 Modular system features. The HPV-02 is based on a modular system with the following characteristics. This enables our distribution partners to configure the product according to your requirements. The latest characteristics and available options can be taken form the model code, which is available on our homepage. >>Size >>Pilot pressure range for H-/E-control >>Vmax >>Control lever geometry >>Mounting flange >>Position of control lever >>Companion flange >>Voltage for E-controls >>Drive shaft >>Cut-off for E-controls >>Direction of rotation >>Connectors for E-controls >>PTO direct mounting >>Arrangement of solenoids >>Tandem pump >>High pressure and charge pressure relief valve >>Internal gear pump >>Cold start relief valve >>External gear pump >>Drain port U + L >>Suction internal gear pump >>Filter/charge pressure manifold >>Direction of GP suction >>Filter flange mounting >>PTO mounting on IGP >>Surface treatment >>Port threads >>Name plate >>Control >>Swash angle sensor Your notes. 35 Post LHY.HPV.01/13.e How to reach us. Linde Hydraulics GmbH & Co. KG Grossostheimer Str. 198 63741 Aschaffenburg Phone +49 6021 150 00 switchboard Fax +49 6021 150 14202 Email info@linde-hydraulics.com Internet www.linde-hydraulics.com Sales companies. (E) (F) (GB) (I) (USA) (BR) (VRC) Linde Hydraulics Iberica S.L. Avda. Prat de la Riba, 181, 08780 Palleja (Barcelona), Phone +34 93 663 32 58, info@linde-hydraulics.com.es Linde Hydraulics France SARL 1, rue du Maréchal de Lattre de Tassigny, 78990 Elancourt, Phone +33 1 30 68 45 40, info.fr@linde-hydraulics.com Linde Hydraulics Ltd. 12-13 Eyston Way, Abingdon Oxfordshire OX14 1TR, Phone +44 1235 522 828, enquiries@lindehydraulics.co.uk Linde Hydraulics Italia SpA Via Del Luguzzone 3, 21020 Buguggiate (VA), Phone +39 0332 877 111, info.it@linde-hydraulics.com Linde Hydraulics Corporation 5089 Western Reserve Road, Canfield Ohio 44 406, Phone +1 330 533 6801, info.us@linde-hydraulics.com Kion South America, Linde Hydraulics do Brasil Rua Victorino, 134 Jardim Mutinga 06463-290 - SP, Brazil, Phone +55 11 99 18 20 438, info.br@linde-hydraulics.com Linde Hydraulics (Xiamen) Co. Ltd. No. 89 Jinshang Road, 361009 Xiamen, Phone +86 592 53 87 701, info@linde-hydraulics.com.cn Turning Power into Motion. Linde Hydraulics GmbH & Co. KG, Grossostheimer Str. 198, 63741 Aschaffenburg Phone +49 6021 150 00, Fax +49 6021 150 14202, www.linde-hydraulics.com
Similar documents
HPR-02. Self-regulating pump for open loop operation.
Linde high pressure units are designed for excellent reliability and long service life. The actual service life of a hydraulic unit is determined by numerous factors. It can be extended significant...
More informationHPR-02. Self-regulating pump for open loop
Linde high pressure units are designed for excellent reliability and long service life. The actual service life of a hydraulic unit is determined by numerous factors. It can be extended significant...
More informationAlbabici TRIATHLON
• RIM: 28” - Ø 700 tubular. Monocoque 100% carbon fiber 3K. Height profile H 90 mm. Brake pads - blu URSUS. • SPOKES: Front: 20 flat head bended black spokes. Rear: 24 flat
More information