HPV-02. Variable pumps for closed loop operation.

Transcription

HPV-02. Variable pumps for closed loop operation.
HPV-02.
Variable pumps for
closed loop operation.
y
y
y
y
y
y
y
y
y
1
control device
modular design, precise and loadindependent
2
swash-plate
hydrostatic bearing
3
piston-slipper assembly
21° swash angle
4
housing
monoshell for high rigidity
5
valve plate housing
highly integrated
6
control piston
integrated, hydraulically captured
7
through shaft
for additional pumps
8
cylinder barrel
compact due to 21° technology
9
integrated pressure relief valves
for system and charge pressure
Design characteristics
>>axial piston pump in swashplate design for high pressure closed loop systems
>>clockwise or counter clockwise rotation
>>exact and rugged servo control devices (mechanical, hydraulic, electro-hydraulic)
>>integrated high pressure relief valves with make-up function
>>integrated low pressure relief valves for charge, control and cooler circuits
>>replaceable cartridge filter
>>SAE high pressure ports
>>SAE mounting flange with ANSI or SAE spine shaft
>>through shaft SAE A, B, B-B, C, D and E
>>charge pressure pumps for internal and external suction, integrated cold start relief valve optional
>>hydrostatic bearings of the rotating group compensate for axial forces
>>optional tandem and multiple pumps
Product advantages
>>compact design
>>high power density
>>dynamic response
>>high reliability
>>long service life
>>noise-optimized
>>precise and load-independent servo control
2
LinDrive = Precision x Dynamics x Reliability = Benefitn
Linde Hydraulics product range
Find the right products for your application.
Product range
Product
Pump
Motor
Valve Technology
Electronics
Application
Linde product name
Self-regulating pump
open loop operation
HPR-02
Variable pump
closed loop operation
HPV-02
Variable motor
closed and open loop operation
HMV-02
Regulating motor
closed and open loop operation
HMR-02
Fixed motor
closed and open loop operation
HMF-02
open loop operation
HMF-02 P
closed and open loop operation
HMA-02
LSC manifold plate
open loop operation
VT modular
Monoblock
open loop operation
Monoblock
Electronic control unit
closed and open loop operation
LINC
Peripheral equipment
closed and open loop operation
Software
diagnosis and configuration
LinDiag®
Content HPV-02.
The closed loop
4
Dimensions
General technical data
5
>> M-controls
26
>> H-controls
27
Operational parameters
>> Life time recommendations
6
>> CA-controls
28
>> Filtration
6
>> E-controls
29
>> Pressure fluids and mounting orientation
7
>> Modular system
30
Torque transmission
8
>> HPV-02 tandem pumps
33
>> Mounting flange
9
>> HPV-HPR-02 multiple pumps
34
>> Drive shaft
10
Modular system features
35
>> PTO flange
11
Your notes
35
>> Output shaft
11
Contact
36
Gear pumps
12
Controls
15
>> Control accuracy
16
>> M. Mechanical-hydraulic
17
>> H. Hydraulic
19
>> CA. Hydraulic-mechanical
21
>> E. Electro-hydraulic
22
The data on which this brochure is based correspond to the current state of development. We reserve the right to make
changes in case of technical progress. The dimensions and technical data of the individual installation drawings are prevailing.
The features listed in this data sheet are not available in all combinations and nominal sizes. Our sales engineers will be happy
to provide advice regarding the configuration of your hydraulic system and on product selection.
3
The closed loop.
Representation of the hydraulic components of a closed loop hydrostatic drive: Variable electro-hydraulic controlled pump HPV-02
E1 (top view) and fixed displacement motor HMF-02 plus filter, cooler and oil tank. The function diagram and the circuit diagram
show two types of cooling.
Function diagram
Option 2: Cooler in return line
Tank
Option 1: Cooler in charge
circuit
External suction
HPV-02 R E1
HMF-02
Circuit diagram
The boost pump is shown with internal and external suction.
Tank
Option 2: Cooler in return line
Option 1: Cooler in charge circuit
External section
HMF-02
HPV-02 R E1
Standard Linde name plate
Each Linde Hydraulics unit features a name plate showing the type and the serial number. For a single order via 'open variant' a
customer-specific number or free text with up to 15 characters can be stamped on the name plate.
Type
Serial-No.
Part No.
4
HPV105-02
Series 02 variable pump, rated size 105
R
Right hand rotation
2553
the last 4 figures of the Bill of Material
H2X
264
Type number of HPV 105-02
T
Letter indicating year of production
12345
Serial number
12345678
Free text field for up to 15 characters
General technical data.
The table shows the complete capacity range of the pumps, while the diagram below shows the recommended practical range for
the different nominal sizes of the HPV-02 pump with control limit between 200 bar ∆pmin and 280 bar ∆pmax . It enables initial
selection of the required nominal pump size.
Overview of technical data
Rated size
55
75
105
135
165
210
280
cc/rev
54.7
75.9
105
135.7
165.6
210.1
281.9
Maximum continuous speed
rpm
3300
3100
2900
2700
2500
2300
2000
Maximum speed (intermittent)
rpm
3700
3500
3200
2900
2700
2500
2200
Minimum continuous speed
rpm
500
Maximum operating pressure
bar
420
Max. pressure (intermittent)
bar
500
Continuous pressure (∆p)
bar
250
Permissible housing pressure
bar
2.5
Continuous input torque
Nm
218
302
418
540
659
836
1122
Maximum input torque
Nm
353
489
677
875
1067
1354
1817
Continuous power
kW
75
98
127
153
173
201
235
kW
122
159
206
247
279
326
381
Maximum displacement
Speed
Pressure
absolute
at continuous pressure
Torque
HPV without charge pump
at max. op. pressure, 19 bar charge pressure
at max. cont. speed, cont. pressure
Power
Maximum power
at max. cont. speed, max. op. pressure, 19 bar
charge pressure
Permissible shaft loads
Permissible housing
temperature
Axial
N
2000
Radial
N
on request
Perm. housing temperature
°C
90
HPV-02
kg
46
49
66
72
113
132
164
dm³
2.1
2.8
3.4
3.8
4.2
4.8
5.5
kgm²x
10-²
0.54
0.84
1.49
2.2
3.11
4.77
9.38
with minimum perm. viscosity > 10 cSt
with H1-control without oil (approx.)
Weights
Filling volume HPV-02
inclusive IGP (size 55-135)
or EGP (size 165-280)
housing with filter
Maximum moment of inertia
Recommended operating range of HPV-02
300
250
Antriebsleistung
Input[KW]
power
[kW]
HPV 280
200
HPV 210
HPV 165
150
HPV 135
HPV 105
100
HPV 75
HPV 55
50
0
1400
1600
1800
2000
AntriebsdrehzahlInput
[U/min]
speed
2200
2400
2600
2800
[rpm]
5
Operational parameters. Life time recommendations
Linde high pressure units are designed for excellent reliability and long service life. The actual service life of a hydraulic unit is
determined by numerous factors. It can be extended significantly through proper maintenance of the hydraulic system and by using
high-quality hydraulic fluid.
Beneficial conditions for long service life
>>Speed
lower continuous maximum speed
>>Operating pressure less than 300 bar ∆p on average
>>Max. pressure
only at reduced displacement
>>Viscosity
15 ... 30 cSt
>>Power
continuous power or lower
>>Purity of fluid
18/16/13 in ac. with ISO 4406 or better
Adverse factors affecting service life
>>Speed
between continuous maximum speed
and intermittent maximum speed
>>Operating pressure more than 300 bar ∆p on average
>>Viscosity
less than 10 cSt
>>Power
continuous operation close to max. power
>>Purity of fluid
lower than 18/16/13 in acc. with ISO 4406
Operational parameters. Filtration
In order to guarantee long-term proper function and high efficiency of the hydraulic pumps the purity of the pressure fluid must
comply with the following criteria according to Linde Works Standard WN 51 210. High purity oil can extend the service time of
the hydraulic system significantly.
>>For reliable proper function
and long service life
18/16/13 in accordance with ISO 4406 or better
>>Minimum requirements
20/18/15 in accordance with ISO 4406
>>Commissioning
The minimum purity requirement for the hydraulic oil is based on the most sensitive system
component. For commissioning we recommend a filtration in order to achieve the required
purity.
>>Filling and operation of hydraulic systems
The required purity of the hydraulic oil must be ensured during filling or topping up. When
drums, canisters or large-capacity tanks are used the oil generally has to be filtered. We
recommend the implementation of suitable measures (e.g. filters) to ensure that the
required minimum purity of the oil is also achieved during operation.
>>International standard
code number according to ISO 4406 purity class according to SAE AS 4059
18/16/13
corresponds to 8A/7B/7C
20/18/15 9A/8B/8C
Filters
Units of the HPV-02 series can be equipped with a pure charge pressure manifold or with a combined charge pressure and filter
flange manifold. The following filter sizes are available, depending on the rated size of the unit. Further details about the mounting
of the charge pressure manifold see section "Dimensions. Modular System".
Filter
6
55
Nr. 2
x
Nr. 3
x
75
105
135
165
210
280
x
x
x
x
x
x
Operational parameters. Pressure Fluids and mounting orientation
In order to ensure the functional performance and high efficiency of the hydraulic pumps the viscosity and purity of the operating
fluid should meet the different operational requirements. Linde recommends using only hydraulic fluids which are confirmed by
the manufacturer as suitable for use in high pressure hydraulic installations or approved by the original equipment manufacturer.
Permitted pressure fluids
>>mineral oil HLP to DIN 51 524-2
>>biodegradable fluids in accordance with ISO 15 380 on request
>>other pressure fluids on request
Linde offers an oil testing service in accordance with VDMA 24 570 and the test apparatus required for in-house testing. Prices
available on request.
Recommend viscosity ranges
Pressure fluid temperature range
[°C]
-20 to +90
Working viscosity range
[mm²/s] = [cSt]
10 to 80
Optimum working viscosity
[mm²/s] = [cSt]
15 to 30
Max. viscosity (short time start up)
[mm²/s] = [cSt]
1000
In order to be able to select the right hydraulic fluid it is necessary to know the working temperature in the hydraulic circuit. The
hydraulic fluid should be selected such that is optimum viscosity is within the working temperature range (see tables).
The temperature should not exceed 90 °C in any part of the system. Due to pressure and speed influences the leakage fluid
temperature is always higher than the circuit temperature. Please contact Linde if the stated conditions cannot be met in special
circumstances.
Viscosity recommendations
Working temperature [°C]
Viscosity class [mm²/s] = [cSt] at 40 °C
approx. 30 to 40
22
approx. 40 to 60
32
approx. 60 to 80
46 or 68
Mounting orientation
The preferred mounting orientation is generally horizontal. Special pump configurations for vertical mounting with the drive shaft
pointing either upward or downward are available for selected rated sizes and have to be requested separately.
For further information concerning the installation of the unit please refer to the operating instructions manual.
7
Torque transmission.
Depending on the selected components, different torques may be transferred. Please ensure that the load transfer components
such as mounting flange, PTO-through shaft and additional pumps are designed adequately. Our sales engineers will be pleased
to provide design advice.
Torque transmission of HPV-02
This shows the input side (A) und PTO-/output side (B) of a HPV-02 pump. The information on the following pages refers to
>> mounting flange and drive shaft (A)
>> PTO flange and through shaft (B).
A) Flange profile
Bolt hole dimensions
55
75
105
135
165
210
280
M1 inside diameter
mm
17.5
17.5
17.5
21.5
21.5
22
22
M2 outside diameter
mm
34
40
34
40
40
38
39
M3 length
mm
20
20
25
20
25
30
30
Bolt hole diameter
8
M2
M1
Bolt hole length
Torque transmission. Mounting flange
Mounting
Mounting flange
in accordance with SAE J744
For rated
size
Washer
Screw
Dimensions
Torque (8.8)
Torque
K
H
V
G
[Nm]
(10.9)* [Nm] [mm] [mm] [mm] [mm]
SAE C, 2 hole
55, 75, 105
17x33x10
M16
195
275
181.0
-
-
-
SAE C, 2 hole
75 & 105
17x33x10
M16
195
275
181.0
-
-
114
SAE D, 2 hole
135
21x37x8
M20
385
540
228.6
-
-
-
SAE D, 2 hole
135
21x37x8
M20
385
540
228.6
-
-
138
SAE D 2 hole
with additional bolt holes (d=17.5mm)
135 & 165
21x37x8
M20
385
540
228.6
230
190
-
SAE E, 4 hole
210 & 280
-
M20
385
540
224.5
-
-
-
with 4 additional threads M12
with 4 additional threads M16
*) Option for standard design, necessary for tandem units
2-hole flange
4-hole flange
2-hole flange
with 4 additional threaded holes
2-hole flange
with 4 additional bolt holes
9
Torque transmission. Drive shaft
A) Dimensions ANSI and SAE drive shafts
Shaft spline
(in accordance with
ANSI B92.1)
12/24, 14 t
SAE-J744
code
(for centring and
shaft)
Outside
diameter
[mm]
Useable spline
length
[mm]
Shaft type
C
31.22
30
34.51
16/32, 21 t
12/24, 17 t
C-C
16/32, 23 t
8/16, 13 t
D, E
16/32, 27 t
8/16, 15 t
F
16/32, 33 t
Available for rated size
55
75
105
135
165
2
x
x
x
39.5
1
x*
x*
37.68
30
2
x
37.68
38.5
1
x*
43.71
50
2
x
x
44.05
62
1
x
x*
50.06
58
1
53.57
58
1
210
280
x
x
x*
x
x*
*) Recommended for tandem configurations
A) Maximum input torque
Rated size
Shaft
55
75
105
135
165
210
280
16/32
21 t
16/32
21 t
16/32
23 t
16/32
27 t
16/32
27 t
8/16
15 t
16/32
33 t
Continuous torque
Nm
435
604
836
1080
1318
1672
2243
Maximum torque
Nm
649
900
1245
1609
1964
2491
3343
Excess length
mm
54
55
55
75
75
75
75
A) Linde Hydraulics shaft types
Type 1. Without undercut
Outside
diamter
Outside
diameter
Type 2. With undercut
Usable spline length
Excess length
10
Usable spline
length
Excess length
Torque transmission. PTO flange
Linde pumps can be combined into tandem and multiple pumps. The combination options are determined by the permitted transfer
torque. The following data refers to the PTO (pump output side, without further attachments).
B) PTO dimensions
Rated size
Z Drive hub profile
in accordance with ANSI B92.1
55
75
105
135
165
210
280
16/32,
15 t
16/32,
18 t
16/32,
19 t
16/32,
21 t
16/32,
22 t
16/32,
24 t
16/32,
27 t
40
42
48
52
63
63
72
D1
mm
D2 spigot pilot diameter
mm
D3
mm
D4
mm
D5 max. bearing clearance
mm
L1
mm
1.5
L2 adapter length
mm
7
L3
mm
L4 minimum distance
mm
35
39
33
35
37
38.5
50.5
L5 usable spline length
mm
14
18
19
20
25
29
30.6
L6 distance to bearing
mm
51
57.5
53
55.9
63.1
68.3
83
L7 min. bearing clearance
mm
3
3
3
4
3
3
-
L8 hole distance 2-hole
mm
82.55
88
89.5
89.5
M 10
30
35
38
M12
43
44.5
47
49
1.9
8
9
106.4
146
B) Output shaft transfer torque
Rated size
55
75
105
135
165
210
280
Continuous transfer torque
Nm
218
302
418
540
659
836
1122
Max. transfer torque
Nm
431
598
763
1069
1305
1655
2221
Torque transmission. Output shaft
B) PTO dimensions
Drive hub profile Z
11
Gear pumps.
Two types of gear pumps are available: internal gear pump IGP and external gear pump EGP. The possible combinations of and
with IGP and EGP are determined by the PTO option and the permitted shaft torque. Both types can be used as charge pump for
the main circuit or the control and cooling circuit. The allowable pressure at the suction port is between 0.8 bar (abs.) and 3.0 bar
(abs.). The charge pressure relief valves for the rated sizes 55-135 are integrated in the port plate housing, and for the rated sizes
165-280 in the charge pressure manifold of the HPV-02.
Technical data
Displacement volume
cc/rev
16
Standard charge pump
for HPV-02
Rated
size
55-105
Type of gear pump
22.5
31
38
44
75-135
165
210
280
IGP
EGP
IGP
EGP
EGP
EGP
Mounting flange and
drive shaft profile
SAE A
16/32,
18 t
SAE A
16/32,
9t
SAE A
16/32,
18 t
SAE A
16/32,
9t
SAE A
16/32,
13 t
SAE A
16/32,
13 t
Type of suction
internal,
external
external
internal,
external
external
external
external
40
210
40
165
275
220
SAE A
16/32,
9t
-
SAE A
16/32,
9t
-
-
-
175
-
75 Nm with SAE A
175
-
-
-
Max. perm. operating pressure
observe max. permissible rated
pressures for filter and cooler
bar
Standard PTO flange and
shaft spline
Continuous output torque
Nm
75 Nm with SAE A
Max. output torque
Nm
107 Nm with SAE A
250
-
107 Nm with SAE A
250
-
-
-
integrated
-
integrated
-
-
-
Cold start relief valve
External gear pump EGP
12
19
Gear pumps.
The IGP charge pumps include a cold start relief valve and a through drive for attaching additional pumps. The suction can be
internal, external or combined. IGP types are available in rated sizes of 16 cc/rev and 22.5 cc/rev.
Internal gear pump IGP with internal suction
Internal suction
A
HPV-02
Combined suction
External suction
A
HPV-02
A
HPV-02
B
B
>>Internal suction
The charge pump supplies the main circuit with oil from the pump housing.
External connection B is closed.
>>External suction
The charge pump supplies the main circuit with oil from the oil tank.
Ther internal connection is closed.
>>Combined suction
The charge pump supplies the main circuit with oil from the pump housing and oil tank.
This type of suction is a combination of internal and external suction.
13
Gear pumps.
PTO flange with IGP
Flange profile 2-hole
Z Internal drive hub profile
in accordance with ANSI B92.1
SAE A
SAE B
SAE B-B
SAE C
16/32, 9 t
16/32, 13 t
16/32, 15 t
12/24, 14 t
D1 Spigot pilot diameter
mm
82.55
101.6
127
D2 Thread size
mm
M 10
M 12
M 16
L1 Hole distance
mm
106.4
146
181
L2 Adapter length
mm
7
11
13
L3 Flange length
mm
-
55
72
Continuous transfer torque
Nm
75
175
Maximum transfer torque
Nm
107
250
PTO SAE A with IGP
PTO SAE B, B-B and C with IGP
Drive hub profile Z
Drive hub profile Z
14
Controls.
The modular control concept with standardised interface enables quick selection and adaptation for different customer and system requirements with mechanical, hydraulic or electronic control. All Series 02-controls feature an upstream signal circuit that
is adapted to the respective control, and a standardised and load-independent servo control for simple and constantly available
machine or vehicle control.
Technical data
Type of control
Additional option
Mechanical
proportional
M1R
Hydraulic
proportional
H1
with pressure cut-off regulation
H1P
speed dependent
CA
torque-/power controlled
CA
with additional safety function
CA
proportional
E1
with pressure cut-off regulation
E1P
with additional safety function
E2
3 position
E5
Electrical
Name of control
E1/E5-control
E1P-control
E2-control
H1-control
H1P-control
CA-control
M1R-control
HPV-02 E2
15
Controls. Control accuracy
All Series 02-pump controls result in the same machine response for identical motion commands, irrespective of the control type.
Corrective action by the operator is no longer required. The reliable control of the pump can easily be integrated into any kind of
vehicle management control system.
Control accuracy of a HPV-02 pump
E2-control
Swash angle pump
100 %
- 100 %
- min
min
- 100 %
Pressure cut-off regulation PCO
100 %
Input signal
y
1
Setting the maximum displacement
Special control elements deal with functions such as torque control or pressure cut-off regulation. Controls with pressure cut-off
regulation (PCO) reduce pump flow when the cut-off pressure is reached. Because system pressure is maintained at low flow, the
power consumption and thermal balance of the system are optimised.
Displacement relative to pilot pressure and pressure cut-off regulation for H- and E-controls
PCO
HP
valve
Pre-loading valve
Min
16
100
Displacement [%]
Pilot pressure ∆p Y/Z [bar]
Max
Regulation begin
0
PCO
Regulation
end
0
High pressure [bar]
Max
Controls. Mechanical-hydraulic M
The M1R-pump control combines robustness with high precision for direct and reliable machine control. It is mechanically controlled
and can be combined with a fixed, variable or regulating hydraulic motor. The control-specific data is independent of the nominal
pump size.
M1R Mechanical control
Flow direction
By turning the control lever the pump flow rate and direction of flow are controlled via a cam plate. The flow direction of the fluid
depends on
>>the pump direction of rotation
>>the over centre direction of the swash plate.
High pressure outlet port
Shaft rotation
(view on Z)
Cam lever direction
P, S A
B
F
X
Ms, Mp L, U
L1, L2
High pressure ports
Pressure port, charge pump
Suction port, charge pump
Feed port, charge and control
Test port, control pressure
Test ports, high pressure
Drain ports
Vent ports
Right hand
Left hand
Note for left hand rotation
A
Suction port, charge pump
B
Pressure port, charge pump
17
Controls. Mechanical-hydraulic M
The cam plate offers a large control angle with progressive control characteristic and a wide neutral range. The resulting high
resolution for movements from the neutral range (and vice versa) enables precise manoeuvring. Reliable and robust control of the
displacement volume is achieved through position feedback.
Displacement [%]
Displacement relative to control angle
Control angle [%]
Control force with max. long lever radius r= 70 mm 17 N
Max. permissible control force (intermittent)
500 N
Control torque
< 1.0 Nm
Control torque out of notch
< 1.5 Nm
Neutral position
24°, 90° (standard), 133°, 144°, 188°, 210°, 232°
Control angle neutral range ... to end position
±3° ... ±48°
Minimum response time with standard restrictors 0.5 s
M1R-cam plate
Control range
neutral dwell
angle + / - 3°
neutral = 90°
reference axis for
neutral position
18
Controls. Hydraulic H
The HPV-02 H1 features hydraulic control with a wide pilot pressure range for improved machine control. It can be combined with a
fixed, variable or regulating hydraulic motor. The data is specific for hydraulic controls, and independent of the nominal pump size
and pressure cut-off regulation PCO, unless specified otherwise otherwise (see section Controls. Control accuracy).
H1. Hydraulic control
Flow direction
By an external hydraulic signal input at the pilot pressure ports (Y, Z) the pump flow rate and direction of flow are controlled. The
flow direction of the fluid depends on the pump direction of rotation and the over centre direction of the swash plate.
High pressure outlet port
Shaft rotation
(view on Z)
Pilot pressure port
H1P. Hydraulic control with PCO
Right hand
Left hand
Y
P
S
Z
S
P
P, S High pressure ports
A
Pressure port, charge pump
B
Suction port, charge pump
F
Feed port, charge and control
X
Test port, pilot pressure
Ms, Mp Test ports, high pressure
L, U
Drain ports
T
Vent port
Y, Z
Pilot pressure ports
Note for left hand rotation
A
Suction port, charge pump
B
Pressure port, charge pump
19
Controls. Hydraulic H
Pilot pressure range
standard: 4-16 bar, option: 4-10 bar differential pressure |Y-Z|
Maximum permissible pressure at Y or Z
30 bar
Minimum response time with standard orifices
for one-way swashing between 0 and max
0.5 s
Displacement relative to pilot pressure
100
Displacement [%]
80
60
Standard: 4 - 16 bar
Option: 4 - 10 bar
40
20
0
2
H1P-control with PCO
20
4
6
8
10
Pilot pressure ∆p = IY-ZI [bar]
12
14
16
18
Controls. Hydraulic-mechanical CA
The HPV-02 CA is a speed-dependent pump control with torque/power regulation. It can be combined with a hydraulic motor as
fixed, variable or regulating motor or a variable motor with pressure regulator. The modular design offers a high degree of versatility in terms of function and control.
CA. Hydraulic-mechanical control
CA-control. Advantages
P, S High pressure ports
A
Suction port, charge pump
F
Feed port, charge and control
Test ports
>>pilot operated system
>> controlled load response
>> temperature independent
>> dynamics
>> precision
>> low hysteresis
>> high versatility (modular design)
>> various motor control possible
Mt Temperature
Ms, Mp High pressure
Y, Z Pilot pressure
Ml For power settings and inch pressure port
Msp Charge pressure
X
Pilot pressure port HMV
L, U Drain ports
L1, L2 Vent ports
T
Drain and vent port
Note for left hand rotation
A
Suction port, charge pump
>>simple adjusting
>>direct control of torque and tractive force
>>speed optimized inching function
>>high safety standard
>> hydrostatic deceleration
Drive with speed-dependent variable pump and variable motor with pressure override
HPV-02 CA
HMV-02 EH1P
Inching pedal
Brake
Not every component shown is part of the Linde product portfolio.
21
Controls. Electro-hydraulic E1 and E5
The HPV-02 E1 has two proportional solenoids and through the upstream signal circuit it combines the flexibility of electronic vehicle management with the reliability of a pump control marked by its high operational availability. Precise and simple. Identical commands always call for the same response in the machine, so no corrective action is required by the operator or the electronic system.
The HPV-02 E5 has two switching solenoids and thus sets the pump to either neutral or maximum swash angle of any direction.
E1. Electro-hydraulic control
E1P. Electro-hydraulic control with PCO
E5. Electro-hydraulic 3 position control
P, S High pressure ports
A
Pressure port, charge pump
B
Suction port, charge pump
F
Feed port, charge and control
X
Test port, pilot pressure
Ms, Mp Test ports, high pressure
L, U Drain ports
T
Vent ports
Note for left hand rotation
A
Suction port, charge pump
B
Pressure port, charge pump
22
Controls. Electro-hydraulic E2
Verstellungen. Elektro-hydraulisch E2
The HPV-02 E2, with its additional release function, can easily be integrated in an electronic vehicle management control system
like an E1-control. In addition it offers a safety standard that meets the stringent requirements for road traffic use. The E2-control
features two proportional solenoids and a switching solenoid.
Die HPV-02 E2 ist mit ihrer zusätzlichen Freigabefunktion ebenso einfach in ein elektronisches Fahrzeugmanagement integrierbar
wie mit einer E1-Verstellung. Darüber hinaus bietet sie den für eine Straßenzulassung erforderlichen hohen Sicherheitsstandard. Die
E2-Verstellung hat zur Ansteuerung zwei Regelmagnete und einen Schaltmagneten.
E2.
Verstellung
E2. Elektro-hydraulische
Electro-hydraulic control
Durchflussrichtung
E2 with switch-off function
Product advantages of E2
Über
ein externes elektrisches Eingangssignal an den Magneten (MY und MZ) werden Volumenstrom und Richtung des
The E2 control offers gesteuert.
an interface
switching off thedes
whole
Pumpenförderstroms
Diefor
Durchflussrichtung
Öls ist abhängig
>>fulfilsvon
the rigorous demands for road traffic use
system.
In
case
of
signal
irregularity
or
perturbation
like
cable
>> der Antriebsdrehrichtung der Pumpe und
>>active drive enable
break or short-circuit in the switching solenoid circuit (co called
>> der Schwenkrichtung der Wiege.
>>minimized susceptibility to interference
'watchdog'), the pump swashes back to neutral position in a
>>with HMF-02: defined swashing back of pump for controldefined manner.
Anschluss
des
Ölaustritts
(siehe
Kapitel
Verstellungen.
Elektro-hydraulisch
E1)
led deceleration
and stop in case of system fault
The vehicle is decelerated until standstill and thus provides a
safe condition of the machine as per EN ISO 13849.
In case of disfunction in the proportional magnets' circuits, a
E2 mit Sicherheitsfunktion
similar reaction can be induced by the intervention of the elecDie elektronische Steuereinheit vergleicht den Fahrbefehl mit
tronic control units.
anderen Maschinensignalen. Bei Abweichung (z.B. bei
Its use is recommended for mobile applications where specific
Stromausfall durch Kabelbruch oder Kurzschluss) deaktiviert die
safety criteria have to be met in terms of travel and coasting
elektronische Steuereinheit den Freigabemagneten an der
behaviour, e.g. road traffic use.
E2-Verstellung und die Pumpe wird aktiv und kontrolliert zurückgeschwenkt. Dadurch wird das Fahrzeug gezielt bis zum
Maschinenstillstand gebremst – ohne den Fahrer zu gefährden.
Der Einsatz empfiehlt sich bei Fahrantrieben mit besonderen
Sicherheitsanforderungen hinsichtlich des Fahr- und Ausrollverhaltens, z.B. bei Straßenfahrt.
>>with HMV-02: diesel overspeed protection by fast swashing
back of pumpE2
Produktvorteile
entspricht den hohen Anforderungen der Strassenzulassung
>>
>>
aktive Fahrtfreigabe
>>
P, S minimierte
High Störanfälligkeit
pressure ports
A kontrollierte
Pressure
port, chargeund
pump
>>
Verzögerung
Stillstand bei evtl.
B Systemstörung
Suction port, charge pump
F
Feed port, charge and control
X
Test
port, control pressure
P, S
Hochdruckanschlüsse
Ms,
Mp
Test
ports, high pressure
A
Druckanschluss
Speisepumpe
Y, Z Test ports, control pressure
B
Sauganschluss Speisepumpe
L, U Drain ports
F
Steuerdruckversorgung
T
Vent port
X Messanschluss Steuerdruck
Ms,
NoteMp
for leftMessanschlüsse
hand rotation Hochdruck
Y,
A Z
L,
B U
T
Messanschlüsse
Suction
port, chargeSteuerdruckanschluss
pump
Leckölanschlüsse
Pressure
port, charge pump
Entlüftungsanschluss
Anmerkung für Linkslauf
A
Sauganschluss Speisepumpe
B
Druckanschluss Speisepumpe
23
Controls. Electro-hydraulic E
E1 control
E1P control
E5 control
E2 control
Flow direction
By an external electrical signal input at the solenoids (MY and MZ) the pump flow rate and direction of flow are controlled. The
flow direction of the fluid depends on
>>the pump direction of rotation
>>the over centre direction of the swash plate.
High pressure outlet port
Shaft rotation
(view on Z)
Active solenoid
24
Right hand
Left hand
MY
P
S
MZ
S
P
Controls. Electro-hydraulic E
The data is specific for electrical controls, and independent of the nominal pump size and PCO pressure cut-off regulation, unless
specified otherwise (see section Controls. Control accuracy). Figures HPV-02 E1 and HPV-02 E2 (page 22, 23) show the standard
mounting position for the respective E-control.
Control signal characteristics
Supply voltage = limiting voltage
V
12
24
DIN EN 175301-803, Deutsch,
AMP Junior Timer (2-pin*)
Connector type
Voltage type
Direct Current (D.C.)
Power consumption
W
Rated current = limiting current
mA
1300
650
mA
450 ± 10
225 ± 5
pilot pressure range
4-10 bar (option)
mA
810
410
pilot pressure range
4-16 bar (standard)
mA
1200
600
swash begin
Control current
swash end
on request
Relative duty cycle
15.6
%
Protection class
100
IP54 (DIN), IP67 (Deutsch), IP6K6K (AMP)
digital control via Pulse Width Modulation
PWM
100 Hz rectangle, pulse duty ratio variable over
control range
analogue control
Direct current with dither overlay
(dither frequency nom. 35 Hz, duty cycle 1:1).
Further details on request
Control types
Minimum response time with standard orifices
s
0.5
*) Coding 1 with proportional solenoids (E1, E1P), coding 2 with switching solenoids (E2, E5)
Displacement relative to control current
24 Volt
(4-16 bar)
Displacement [%]
24 Volt
(4-10 bar)
12 Volt
(4-10 bar)
12 Volt
(4-16 bar)
Control current [mA]
25
Dimensions. M-controls
Control-specific dimensions for HPV-02 with mechanical-hydraulic controls.
Port sizes and dimensions for M-controls
Rated size
D1 [mm]
B1 [mm]
B2 [mm]
B3 [mm]
B4 [mm]
B5 [mm]
L1 [mm]
L2 [mm]
L3 [mm]
L4 [mm]
L5 [mm]
L6 [mm]
H1 [mm]
H2 [mm]
H3 [mm]
P
S
A gear pump
B gear pump
L
U
F
X
Mp
Ms
L1
L2
55
75
127
181
101
101
192
105
116
116
216
242
304
359
267
329
385
88
95
184
SAE ¾“
SAE ¾“
93
103
188
99
105
193
SAE 1“
SAE 1“
M27x2
M36x2
M22x1.5
M22x1.5
M22x1.5
Threads metric in accordance with ISO 6149-1
Suction port at IGP in accordance with ISO 8434-1 L28
High pressure ports similar to ISO 6162-2
Socket cap screw in accordance with ISO 4762
26
165
152.4
228.6
225
282
335
Further threads on request
135
141
141
141
138.5
219
233
194
288
319.5
350
485.5
425
560.4
151
70
48
106
119.5
112
122.5
198
214.5
SAE 1 ¼“
SAE 1 ¼“
SAE 1“
SAE 1 ¼“
M27x2
M27x2
M14x1.5
M14x1.5
M14x1.5
M22x1.5
M22x1.5
210
280
165.1
224
142
135
240
225
155
246
346
516
591
392
571
646
134
152
133
150
226
238
SAE 1 ½“
SAE 1 ½“
SAE ¾“
SAE 1 ¼“
M27x2
M33x2
M27x2
M33x2
M27x2
Dimensions.
H-controls
Maße. H-Verstellungen
Control-specific dimensions
controls.
Verstellungsspezifische
MaßeforfürHPV-02
HPV-02with
mit hydraulic
hydraulischen
Verstellungen.
Anschlüsse
unddimensions
Maße für H-Verstellungen
Port sizes and
for H-controls
mit MDR
PF
ST
AX Zahnradpumpe
BMp
Zahnradpumpe
LMs
UY
FZ
5555
165
280
165
210
152.4
165.1
38
44
22,5
16
228.6
224
225
101 2-Loch Anschlussbild
116
141
134.5 4-Loch
143 Anschlussbild
155
101
141D
134.5
135
139
SAE C 116
SAE
SAE E
192
216
219
233
240
246
16 / 32 Teilung Verzahnung
16 / 32
231
21 Zähne
23 Zähne 27 Zähne
Zähne
Zähne 33392
225
242
267
288
319.5 27346
152,4
127
282
304
329
350
485.5
516 165,1 571
228,6
181
225
224
335
359
385
425
560.4
591
646
101
116
141
155
143
133
101
116
141
139
135
88
93
99
106
119.5
134
152
192
216
219
246
240
95
103
105
112
122.5
133
150
231
194
154
158
163
187
191 231 204
267
242
225
288
392
346
185
190
194
199
223
201
214
329
304
282
350
571
516
SAE ¾“
SAE 1“
SAE 1 ¼“
SAE 1 ½“
385
359
335
425
646
591
SAE ¾“
SAE 1“
SAE 1 ¼“
SAE 1 ½“
133
133
M27x2
SAE 1“
SAE ¾“
152
134
106
99
88
93
M36x2
SAE 1 ¼“
SAE 1 ¼“
150
112
105
95
103
133
M22x1.5
M27x2
M33x2
163
158
194
154
204
191
M22x1.5
M27x2
M33x2
199
194
185
190
201
214
M22x1.5
M27x2 SAE 1 1M27x2
1/4“
/
SAE
1
SAE 3/4“
SAE 1“
2“
M22x1.5
1/4“
1
SAE 3/4“
SAE
1
/
SAE
1
SAE 1“
2“
M14x1.5
3
SAE /4“
M27x2
M14x1.5
SAE 1 1/4“
M27x2
M14x1.5
M27x2
M22x1,5
M33x2
M14x1.5
M27x2
M33x2
M22x1,5
M14x1.5
M27x2
M27x2
M22x1,5
T
X
Mp
Ms
Y
Z
7575
127
181
105
105
135
135
in Entwicklung
Rated size
Nenngröße
D1
[mm]
Zahnradpumpen
B1 [mm] [cm³]
Nenngröße
B2 [mm]
FB3
Flanschprofil
[mm]
B4 [mm]
W Wellenprofil
B5 [mm]
nach
ANSI B92.1
L1 [mm]
D1 [mm]
L2 [mm]
B1 [mm]
L3 [mm]
B2 [mm]
L4 [mm]
B3 [mm]
H1 [mm]
B4 [mm]
H2 [mm]
B5 [mm]
w/o PCO
L1
H3 [mm]
with PCO
L2 [mm]
P
L3 [mm]
S
L4 [mm]
A gear pump
H1 [mm]
B gear pump
H2 [mm]
L
ohne MDR
H3
U [mm]
M22x1,5
M14x1,5
M14x1,5
M14x1,5
M14x1,5
M14x1,5
M22x1,5
M14x1,5
M14x1,5
M14x1,5
M14x1,5
M14x1,5
Anschlussgewinde metrisch nach ISO 6149
Befestigungsgewinde an den SAE Hochdruckanschlüssen
metrisch nach ISO 261
Zylinderschrauben nach ISO 4762
Wellenprofil W
Flanschprofil F
Weitere Gewinde auf Anfrage
Threads metric in accordance with ISO 6149-1
Suction port at IGP in accordance with ISO 8434-1 L28
High pressure ports similar to ISO 6162-2
Socket cap screw in accordance with ISO 4762
Further threads on request
26
27
Dimensions. CA-controls
Control-specific dimensions for HPV-02 with hydraulic-mechanical controls.
Port sizes and dimensions for CA-controls
Rated size
55
D1 [mm]
75
105
127
B1 [mm]
152.4
181
B2 [mm]
101
B3 [mm]
101
B4 [mm]
193
228.6
116
141
116
141
212
B5 [mm]
214
217
336
L1 [mm]
225
242
267
288
L2 [mm]
282
306
331
351.5
L3 [mm]
343
361
386.3
426.1
99
105.5
L4 [mm]
207
H1 [mm]
88
93
H2 [mm]
95
103
99
104
H3 [mm]
178
184
187.8
191.1
A gear pump
M36x2
P
SAE 1“
S
SAE 1“
L
M22x1.5
U
M22x1.5
F
M22x1.5
T
M22x1.5
X1
M14x1.5
Mp
M14x1.5
Ml
M14x1.5
Ms
M14x1.5
Msp
M14x1.5
Mt
M14x1.5
Y
M14x1.5
Z
M14x1.5
Threads metric in accordance with DIN 3852-1
Suction port at IGP in accordance with ISO 8434-1 L28
High pressure ports similar to ISO 6162-2
Socket cap screw in accordance with ISO 4762
Further threads on request
28
135
Dimensions. E-controls
Control-specific dimensions for HPV-02 with electro-hydraulic controls.
Port sizes and dimensions for E-controls
Rated size
D1 [mm]
B1 [mm]
B2 [mm]
B3 [mm]
B4 [mm]
B5 [mm] E1
B5 [mm] E2
L1 [mm]
L2 [mm]
L3 [mm]
L4 [mm]
H1 [mm]
H2 [mm]
55
75
127
181
105
135
165
210
280
225
282
335
242
304
359
267
329
385
88
95
93
103
99
105
152.4
228.6
141
134.5
141
134.5
219
233
226
230
288
319.5
350
485.5
425
560.4
183
106
119.5
112
122.5
H4 [mm] E1 / E2
159
164
168
173
189.5
218
231
H4 [mm] E1
195
200
204
209
225.5
254
(267)
P
S
Mp
Ms
A gear pump
B gear pump
L
U
F
T
X
Y
Z
F2
SAE ¾“
SAE ¾“
AMP-JT connectors
DIN connectors
101
101
192
116
116
216
SAE 1“
SAE 1“
M27x2
M36x2
M22x1.5
M22x1.5
M22x1.5
SAE 1 ¼“
SAE 1 ¼“
M14x1.5
M14x1.5
SAE 1“
SAE 1 ¼“
M27x2
M27x2
165.1
224
143
135
240
225
155
139
246
346
516
591
392
571
646
134
133
152
150
SAE 1 ½“
SAE 1 ½“
SAE ¾“
SAE 1 ¼“
M33x2
M33x2
M27x2
M22x1.5
M14x1.5
M14x1.5
M14x1.5
M14x1.5
Threads metric in accordance with ISO 6149-1
Suction port at IGP in accordance with ISO 8434-1 L28
High pressure ports similar to ISO 6162-2
Socket cap screw in accordance with ISO 4762
Further threads on request
29
Dimensions. Modular system
The following diagrams show the proportions of similar components.
Gear pump IGP 16 cc/rev
without cover
Gear pump IGP 22.5 cc/rev with
cover
Filter arrangement right
(PTO view) for size 55 - 105
(filter no.3)
(filter no.2)
PTO view
>>M1R-control
>>IGP 16 cc/rev without cover
>>IGP 22.5 cc/rev with cover
>>filter mounting side for rated sizes 55 - 105
AMP-JT-connector standard mounting position
for E2-control
Release solenoid
for E2-control
AMP-JT-connector mounting position
turned by 90° for E2-control
DIN-connector mounting position
turned by 90° for E1-control
E-control
DIN-connector standard mounting
position for E1-control
Charge pressure manifold
for HPV 165-02 - 280-02
PTO-through drive SAE A
Manual override for
DIN-connector
Filter flange
for HPV 165-02 - 280-02
Gear pump EGP
Filter arr. left (PTO view)
for size 135 - 280
PTO view
30
>>E1-control with mounting postition of solenoid connectors
>>filter mounting side for rated size 135 - 280
>>E2-control with mounting postition of solenoid connectors
>>charge pressure manifold for rated size 210 and 280
>>manual override
>>DIN-connector
>>SAE A PTO-mounting flange
>>AMP-JT-connector
>>EGP
without filter
Dimensions. Modular system
The following diagrams show the proportions of similar components.
H1-control
charge flow inlet flange 90°
4-hole mounting
flange
2-hole mounting flange
mounting flange view
>>4-hole mounting flange
>>H1-control
>>2-hole mounting flange
>>filter flange 90° without filter
Lever offset version
Lever straight version
(IZP 22,5 cc/rev)
(IZP 16 cc/rev)
Companion flange
(filt
er n
o.2
(filt
)
er n
o.3
)
(filt
er n
o.2
)
(filt
er n
o.3
)
(EGP 31 cc/rev)
(EGP 38 cc/rev)
(EGP 44 cc/rev)
side view (size 55 -105)
>>M1R-control lever geometry
>>IGP
>>EGP
>>filter
>>companion flange
31
Dimensions. Modular system
The following data enable quick calculation of the overall maximum external dimensions. In each case only the relevant dimensions are shown so that length, width and height can simply be determined through addition. The actual fitting dimensions of the
respective units are shown on the installation drawing.
External dimensions for addition
y
1
y
2
y
3
y
y
y
4
5
6
55
Type
Length
230
Width
210
Height
185
75
245
235
190
105
270
235
210
135
290
280
220
165
320
270
245
210
350
290
275
280
395
315
305
M1R
-
10
95
H1
-
5
55
H1P
-
10
75
CA
-
135
95
E1/E5
-
5
110
E1P
-
10
110
Component
Basic unit
Control
E2
Gear pump
Filter
-
15
110
16 cc
60
-
-
22,5 cc
65
-
-
31 cc
135
-
-
38 cc
175
-
-
44 cc
180
-
-
10
without gear pump
95
-
105
-
15
50
-
75
-
-
Nr.2
Nr.3
F-port 90°
Companion flange
not shown
Intermediate flange
Shown in section
<<Dimensions. Tandem pumps>>
55 -> SAE C
47.5
75 -> SAE C
47.5
105 -> SAE C
135 -> SAE D / C
165 -> SAE D / C
61.5 / 26
210 -> SAE E / D / C
55 / 68 / 32
280 -> SAE E / D / C
39 / 39 / 45.5
Example:
HPV 135-02 H1 with IGP 22.5, filter no. 3 and companion flange
32
37.5
50 / 31
L. 440 mm B. 390 mm
H. 275 mm
Dimensions. HPV-02 tandem pumps
Tandem pumps are created by connecting individual HPV units in series, with the pumps arranged by capacity. Positioning the
charge pump(s) at the end of the tandem ensures optimum space utilisation, output allocation and load distribution.
6
p
front pum
L1
rear pump
L2
L3
Overall length of tandem pump
Rated size
Rear pump
HPV 55
HPV 75
HPV 105
HPV 135
HPV 165
HPV 210
HPV 280
Front pump
Lengths [mm]
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
496
553
607
513
575
631
529
591
647
543
605
680
571
746
820
610
782
857
655
834
909
530
592
648
546
608
663
560
622
696
588
763
837
627
799
874
672
851
925
572
634
586
586
648
722
613
788
865
653
825
900
698
877
951
640
702
777
670
844
919
702
874
947
723
903
978
684
859
934
722
897
971
755
935
1009
731
903
978
777
956
1030
823
1002
1076
HPV 55
with IGP 16 cc
at rear pump
HPV 75
with IGP 22,5 cc
at rear pump
HPV 105
with IGP 22.5 cc
at rear pump
HPV 135
with IGP 22.5 cc
at rear pump
HPV 165
with EGP 38 cc
at rear pump
HPV 210
with EGP 38 cc
at rear pump
HPV 280
with EGP 44 cc
at rear pump
33
Dimensions. HPV-HPR-02 multiple pumps
Multiple pumps are created by combining individual pump units in series, with the pumps arranged by capacity. Positioning the
gear pump(s) at the end of the unit ensures optimum space utilization, output allocation and load distribution. The following table
is based on the gear pump acting as charge pump for the HPV-02 variable pump.
p
front pum
L1
rear pump
L2
L3
Overall length of multiple pump
Rated size
Rear pump
Front pump
Lengths [mm]
HPV 55
with IGP 16 cc at HPR
HPV 75
with IGP 22.5 cc at HPR
HPV 105
with IGP 22.5 cc at HPR
HPV 135
with IGP 22.5 cc at HPR
HPV 165
with EGP 38.5 cc at HPR
HPV 210
with EGP 38.5 cc at HPR
HPV 280
with EGP 44 cc at HPR
34
HPR 55
HPR 75
HPR 105
HPR 135
HPR 165
HPR 210
HPR 280
L1
492
-
-
-
-
-
-
L2
549
-
-
-
-
-
-
L3
603
-
-
-
-
-
-
L1
509
521
-
-
-
-
-
L2
586
598
-
-
-
-
-
L3
642
653
-
-
-
-
-
L1
525
536
567
-
-
-
-
L2
602
613
629
-
-
-
-
L3
657
669
684
-
-
-
-
L1
539
550
581
637
-
-
-
L2
616
627
643
699
-
-
-
L3
690
702
717
774
-
-
-
L1
565
578
608
667
715
-
-
L2
741
753
783
842
882
-
-
L3
815
827
857
916
956
-
-
L1
606
618
648
699
722
733
-
L2
793
805
820
871
897
905
-
L3
868
879
895
945
972
980
-
L1
651
663
693
720
768
779
834
L2
845
856
872
900
948
958
1014
L3
919
931
946
975
1023
1033
1089
Modular system features.
The HPV-02 is based on a modular system with the following characteristics. This enables our distribution partners to
configure the product according to your requirements. The latest characteristics and available options can be taken form the model
code, which is available on our homepage.
>>Size
>>Pilot pressure range for H-/E-control
>>Vmax
>>Control lever geometry
>>Mounting flange
>>Position of control lever
>>Companion flange
>>Voltage for E-controls
>>Drive shaft
>>Cut-off for E-controls
>>Direction of rotation
>>Connectors for E-controls
>>PTO direct mounting
>>Arrangement of solenoids
>>Tandem pump
>>High pressure and charge pressure relief valve
>>Internal gear pump
>>Cold start relief valve
>>External gear pump
>>Drain port U + L
>>Suction internal gear pump
>>Filter/charge pressure manifold
>>Direction of GP suction
>>Filter flange mounting
>>PTO mounting on IGP
>>Surface treatment
>>Port threads
>>Name plate
>>Control
>>Swash angle sensor
Your notes.
35
Post
LHY.HPV.01/13.e
How to reach us.
Linde Hydraulics GmbH & Co. KG
Grossostheimer Str. 198
63741 Aschaffenburg
Phone
+49 6021 150 00 switchboard
Fax
+49 6021 150 14202
Email
info@linde-hydraulics.com
Internet
www.linde-hydraulics.com
Sales companies.
(E)
(F)
(GB)
(I)
(USA)
(BR)
(VRC)
Linde Hydraulics Iberica S.L.
Avda. Prat de la Riba, 181, 08780 Palleja (Barcelona), Phone +34 93 663 32 58, info@linde-hydraulics.com.es
Linde Hydraulics France SARL
1, rue du Maréchal de Lattre de Tassigny, 78990 Elancourt, Phone +33 1 30 68 45 40, info.fr@linde-hydraulics.com
Linde Hydraulics Ltd.
12-13 Eyston Way, Abingdon Oxfordshire OX14 1TR, Phone +44 1235 522 828, enquiries@lindehydraulics.co.uk
Linde Hydraulics Italia SpA
Via Del Luguzzone 3, 21020 Buguggiate (VA), Phone +39 0332 877 111, info.it@linde-hydraulics.com
Linde Hydraulics Corporation
5089 Western Reserve Road, Canfield Ohio 44 406, Phone +1 330 533 6801, info.us@linde-hydraulics.com
Kion South America, Linde Hydraulics do Brasil
Rua Victorino, 134 Jardim Mutinga 06463-290 - SP, Brazil, Phone +55 11 99 18 20 438, info.br@linde-hydraulics.com
Linde Hydraulics (Xiamen) Co. Ltd.
No. 89 Jinshang Road, 361009 Xiamen, Phone +86 592 53 87 701, info@linde-hydraulics.com.cn
Turning Power into Motion.
Linde Hydraulics GmbH & Co. KG, Grossostheimer Str. 198, 63741 Aschaffenburg
Phone +49 6021 150 00, Fax +49 6021 150 14202, www.linde-hydraulics.com

Similar documents

HPR-02. Self-regulating pump for open loop operation.

HPR-02. Self-regulating pump for open loop operation. Linde high pressure units are designed for excellent reliability and long service life. The actual service life of a hydraulic unit is determined by numerous factors. It can be extended significant...

More information

HPR-02. Self-regulating pump for open loop

HPR-02. Self-regulating pump for open loop Linde high pressure units are designed for excellent reliability and long service life. The actual service life of a hydraulic unit is determined by numerous factors. It can be extended significant...

More information

Albabici TRIATHLON

Albabici TRIATHLON • RIM: 28” - Ø 700 tubular. Monocoque 100% carbon fiber 3K. Height profile H 90 mm. Brake pads - blu URSUS. • SPOKES: Front: 20 flat head bended black spokes. Rear: 24 flat

More information