Why DEWETRON? - Milano Systems

Transcription

Why DEWETRON? - Milano Systems
SHORT FORM CATALOG
From our founding in 1989,
DEWETRON has become a
market-leading provider of
test and measurement systems. Our 200+ employees
are located at our headquarters in Graz, Austria and also in more than 25
countries around the world.
DEWETRON is a member of
the TKH group.
We provide highest quality Test & Measurement Solutions for
Automotive
Power & Energy
Aerospace
Transportation
General T & M
Reference Customers
NASA, Airbus, OMV, Lockheed Martin, Lufthansa, Honda, Harley Davidson, Johnson & Johnson, Renault, Rolls Royce,
Windtest, Verbund Hydro, Rockwell Collins, Schindler, Trumpf, Technical University Vienna, Pirelli, Kawasaki, Bell
Helicopter, Boeing Commercial Airplanes, Bombardier, New York Subway, Trenitalia, Continental, and many more ...
2
www.de we t ron .com
We have the expertise & we go the extra mile for our customers
About us
Since 25 years data acquisition is all we do. As we are producing
instruments each new development is based on huge experience
in making data acquisition systems.
Customization is one of our biggest strengths - we love the challenge and we like to go the extra step for our customers to enable
highest quality test and measurement data in shortest time.
TRION Systems
There is a whole team of application engineers with 10+ years of
experience to support challenging applications.
Quality
ORION Systems
Our commitment to Total Quality Management is based on the understanding of what is important for the success of our customers. It starts with the
definition of the technical specification, covers the development, production, quality control, shipment, and ends with support and service of our
systems during operation.
DEWETRON is ISO 9001:2008 and ISO 14001:2009 certified. Environmental
and quality management is more than just a compliance issue for us; it is
an integral part of our business operations.
Shaketest procedure
ISO certificate
DEWE-ACADEMY
In the DEWE-ACADEMY single or multi-day events are offered. Professionals teach the
practical application of our measurement systems, based on the relevant theory.
ACADEMY
Calibration
Software
DEWETRON maintains two top-notch
calibration facilities with the same
equipment: one at our worldwide
headquarters in Austria, and another
one at DEWETRON USA in Rhode
Island. Our cal lab is based on the
Fluke 5500 series calibrator, and we
run the METCAL calibration system,
which allows us to automate nearly
every process.
Dedicated Instruments
Extensive temperature tests (-40 to +70 °C)
CVT Logger
Front-ends
We take quality very seriously! That is why we have our own environmental
test facilities in our building in Austria, where all DEWETRON products are
tested..
www.dewetron.com/dewe-2600
3
Content
About us
Why DEWETRON
5
Instrument families
6
System overview
7
Unlimited measurements with more...
8
TRION Systems
TRION series modules
10
All-in-One TRION systems
11
Mainframes TRION 12
Front-ends TRION
14
Distributed systems over large distance
15
ORION Systems
ORION A/D boards
16
High-speed amplifiers
17
Dynamic amplifiers
18
Differential amplifiers
20
MSI Series
21
All-in-One ORION systems
22
Mainframes ORION
24
Front-ends
PCI front-ends ORION
26
USB & Ethernet front-ends ORION
27
EPAD/CPAD signal conditioning
28
CVT Logger
CVT Logger
30
Dedicated Instruments
Power Network Analyzers
31
Power Fault Recorders
32
Power Measurement
33
Software
Marlin 34
LabVIEW™library 36
NItrogen 37
DASYLab Drivers 38
DS-740
DEWETRON OEM 41
Accessories
Accessories42
4
www.de we t ron .com
ADC-clock
Counter/encoder inputs of TRION™ modules are phase synchronized.
Refering to the diagram, you can see that a standard counter is always a
sample behind. With software interpolation you can get closer, but only
DEWETRONs advanced technology is both, fully phase AND amplitude
corrected.
Counter input
Ideal counting
SuperCounter™
Software interpolation
Standard counter
Scalable and Modular
The ability to scale from a few channels to many and to split in several housings
without compromising the simultaneous data sampling of all channels is unique.
User Exchangeable Modules
All TRION™ amplifier modules can be changed within a few seconds. Modules in
different sampling speed and resolution can be used in one chassis. Use isolated
and differential inputs at the same time.
Global Support
Our engineers are in 25 countries around the world to support you with their knowledge and expertise. We offer maintenance, upgrades, ISO certified system calibrations and also customer trainings!
ORION Systems
SuperCounter™
Front-ends
TRION™ series modules easily take it on with all similar products on the market.
CVT Logger
Highest Precision
Dedicated Instruments
The quality of synchronized measurement data has top priority at DEWETRON which
is guaranteed by the SYNC-CLOCK™ technology. Analog, digital, GPS, counter, CANbus, ARINC and video as well as major sensor systems like Kistler RoaDyn ® 2000 wheel
or GeneSys ADMA INS/GPS system etc. are already recorded synchronously during
the measurement.
Software
SYNC-CLOCK™ Technology
TRION Systems
About us
Why DEWETRON?
5
Instrument Families
There are two product families of DEWETRON data acquisition systems, the DEWE2 (TRION™) and the DEWE
(ORION) series. All instruments of both series can record vastly different signal sources in perfect sync. The analog
input modules are leading technology and guarantee precise and robust results while offering the right input for
almost any sensor.
Sensor
Flexible
connector panel
Signal conditioning
Filtering
A/D conversion
High speed
data transfer and
synchronization
DEWE2 Series with TRION™ Modules
DATA ACQUISITION MODULES
HOUSING AND STORAGE
Counter
CAN bus
Analog signal conditioning
& A/D conversion
USER EXCHANGEABLE TRION™ MODULES
WIDE RANGE OF HOUSINGS
Highest precision
Most rugged
Highest channel density
Fully modular: user exchangeable modules
for analog, digital, counter, CAN
DEWE Series with ORION Cards and DAQ Modules
SIGNAL CONDITIONING MODULES HOUSING AND STORAGE AND I/O CARDS
Analog signal conditioning
A/D conversion
DEWE-ORION
A/D CARDS
Counter
CAN bus
ANALOG DAQ MODULES
Isolated or differential analog inputs
A/D resolution 16, 22 or 24 bit
6
WIDE RANGE OF HOUSINGS
Separated A/D card for flexible sampling
rates up to 10 MS/s
www.de we t ron .com
About us
System Overview
IN
ADC
TRION Systems
All-in-one
OUT
Built-in display, keyboard and touchpad
Most compact and flexible configuration
Powerful PC inside for fast online displays
and analsis
ORION Systems
Most convenient for mobile applications
Mainframes
ADC
OUT
Front-ends
IN
Keyboard and pointing device are included loose
Powerful PC inside for fast online displays and analysis
Can be used with external display
CVT Logger
Very popular for applications where the instrument is
installed in a poorly visible place for the user
Front-ends
ADC
OUT
Dedicated Instruments
IN
Robust high-speed PCI Express bus
To be used with an external computer
Expansion for A or M instruments
Multiple units can be daisy-chained
Signal Conditioning
Software
Stand-alone signal conditioning
Front-ends for existing recorders, A/D cards …
Channel expansion for DEWETRON instruments
Signal Conditioning Amplifier
AD Conversion
Computer inside
Display
7
Unlimited Measurements with...
... more CHANNELS
High-speed expansion
Add one or more
Front-end chassis
for high-speed
expansion
DEWE2-F7s
DEWE2-F4s
Network setup on
page 15
TRION-SYNC-bus
PCIe connection up to 7 meters
Low-speed expansion
100 Hz
CPAD3 modules
with CAN interface
Quasi-static expansion
12 Hz
Add one or more
EPAD2 modules at
any time
... more SOFTWARE
8
www.de we t ron .com
About us
... more CONNECTIVITY
Analog inputs
TRION Systems
Digital inputs
Counter
Video
ARINC-429, MIL-STD-1553
GPS, VGPS, absolute timing
ORION Systems
Inertial data
CAN
PCM telemetry
FlexRay
Front-ends
XCP
CVT Logger
-12,5
-100
... more INSIGHT
Infrared cam
Software
High-speed cam
Dedicated Instruments
250
162,5
162,5
Rec
10 MS/s sampling rate
1 MS/s sampling rate
U1_1MS; - [V]
75
U1_10MS; - [V]
75
-12,5
-100
50 MB/s
SYSTEM B
100 MB/s
SYSTEM A
150 MB/s
SYSTEM C
200 MB/s
DEWE-2600-STREAM
305 MB/s
250
... MORE POWER
GigE cam
USB cam
9
Modules
Simultaneous sampling for DEWE2 series
Separate ADC on each channel
User exchangeable modules
ANALOG Modules
Channels
V
TRION-2402-MULTI
TRION-1620-ACC
TRION-1620-LV
TRION-2402-V
TRION-1603-LV
204.8 kS/s
24 bit
yes
DSUB, LEMO 0B
V
6
2 MS/s
1 MS/s
16 bit
24 bit
yes
BNC
V
6
2 MS/s
1 MS/s
16 bit
24 bit
yes
BNC, LEMO 1B
V
4 or 8
204.8 kS/s
24 bit
yes
Safety banana sockets
V
6
250 kS/s
16 bit
yes
BNC, LEMO 1B
6 to 8
204.8 kS/s
24 bit
no
RJ-45, DSUB,
LEMO 1B, LEMO 0B
204.8 kS/s
24 bit
no
SMB, BNC
100
100
1000
100
TRION-2402-dACC
V
V
10
V
6 to 8
100
Voltage (1000 V)
Current (shunt needed)
Bridge
DIGITAL Modules
IEPE
Channels
RTD
Potentiometer
Sample rate
Resolution Isolation
per channel
SuperCounter™ inputs
Connector Type
TRION-CNT
6 to 18
800 kS/s
80 MHz
yes
DI, CNT
TRION-DI-48
48
2 MS/s
80 MHz
yes
DI
TRION-BASE
1 to 8
2 MS/s
80 MHz
-
DI, DIO, CNT, SYNC, AUX
1 to 8
2 MS/s
80 MHz
-
GPS antenna, IRIG In / Out,
DIO, CNT, SYNC, AUX
TRION-TIMING
DEDICATED Modules
GPS
00101001010001
TRION-CAN
Channels
Sample rate
Resolution Isolation
per channel
Connector Type
2 or 4
n/a
n/a
yes
DSUB
1
n/a
n/a
-
DSUB
1 CNT
8 DIO
2 MS/s
0.01 km/h
< 10 cm
-
GPS antenna, IRIG In / Out,
DIO, CNT, SYNC, AUX
TRION-A429
4, 8, 16
or 30
-
n/a
-
SCSI-3
TRION-M1553
1,2 or 4
-
n/a
-
SCSI-3
TRION-MA4
9, 10, 12
or 13
-
n/a
-
SCSI-3
Update rate
max. 2.8
MS/s
2
16 bit
-
BNC
TRION-FLEXRAY
TRION-VGPS
TRION-1628-AO-2
10
Connector Type
4 or 8
100
TRION-2402-dSTG
1000
Sample rate
Resolution Isolation
per channel
GPS
www.de we t ron .com
About us
All-in-One
TRION Systems
Built-in display, keyboard and touchpad
Most compact and flexible configuration
Powerful PC inside for fast online displays and analysis
Slots for TRION™ acquisition modules
DEWE2-A4
DEWE2-A7
DEWE2-A13
4
7
13
High-speed channel expansion
Add Front-end chassis or setup network
Low-speed channel expansion 100 Hz
CPAD3 via TRION-CAN
EPAD2
120 GB removable Solid State Disk
1 TB hard disk
Up to 480 GB SSD
Up to 480 GB SSD
Optional data storage
Display
13“ (1280 x 800)
17“ (1920 x 1080)
FULL HD
Power supply
10 to 36 VDC isolated
incl. external AC power supply
90 to 264 VAC
Option 1
Internal buffer battery
for ~ 5 min. operation
max. 10 to 36 VDC
Internal buffer battery for ~ 2 min. operation
Option 2
DW2-UPS-150-DC (ext. battery pack),
2 battery slots
Battery powered, 4 battery slots for ~2 hours operation
318 x 253 x 128 mm
(12.5 x 10 x 5 in.)
450 x 246 x 303 mm
(17.7 x 9.7 x 11.9 in.)
Typ. 5.9 kg (13 lb.)
Typ. 15 kg (33 lb.)
Input voltage (max.)
Dimensions
Dimensions (W x D x H)
(without handle)
Weight without modules and batteries 1)
Software
Weight of one battery: 660 g (1.45 lb.)
CVT Logger
Data storage
Dedicated Instruments
Quasi-static channel expansion
Front-ends
ORION Systems
Most convenient for mobile applications
DEWE-CAM-01
Add video data to your measurements via
high shock and vibration resistant camera
DW2-UPS-150-DC,
130 W UPS with 2 slots for batteries
DW2-A13-CC
Shipping/carrying case
11
Mainframes
Most compact and flexible configuration
Powerful PC inside for fast online displays and analysis
Most convinient for mobile applications
Slots for TRION™ acquisition modules
High-speed channel expansion
DEWE2-M4
DEWE2-M4s
4
4
7
n/a
Add Front-end chassis or
setup network
Add Front-end chassis or
setup network
Low-speed channel expansion 100 Hz
CPAD3 via TRION-CAN
Quasi-static channel expansion
Data storage
DEWE2-M7s
EPAD2
EPAD2 or CPAD2 via TRION-CAN
120 GB removable Solid State Disk
Optional data storage
120 GB Solid State Disk
up to 480 GB
Power supply
10 to 36 VDC isolated;
incl. external AC power supply
Standard (max.)
Add internal buffer battery
for ~ 5 min. operation
Option 1
DW2-UPS-150-DC (ext. battery pack),
2 battery slots
n/a
DEWE-UPS-300-DC
Dimensions (W x D x H)
(without handle)
318 x 253 x 108 mm
(12.5 x 10 x 4.3 in.)
177 x 230 x 177 mm (4 u)
(7 x .9.1 x 7 in.) without feet
258 x 230 x 177 mm (4 u)
(10.2 x 9.1 x 7 in.) without feet
Weight without modules and batteries1)
Typ. 3.9 kg (8.6 lb.)
Typ. 3.9 kg (8.6 lb.)
Typ. 4.9 kg (10.8 lb.)
Option 2
Dimensions
1)
Weight of one battery: 660 g (1.45 lb.)
CAM-SPLIT-BOX
12
BAT-CHARGER-1
BAT-CHARGER-4
DE-POWERBOX-12
DC Power distribution box
www.de we t ron .com
About us
TRION Systems
ORION Systems
DEWE2-M13
DEWE2-M18
13
13
18
Add Front-end chassis or setup network
Ethernet
CPAD3 via TRION-CAN
1 TB Hard Disk (plus two 3,5“ bays)
120 GB Solid State Disk
up to 480 GB
up to 3 TB
up to 480 GB
10 to 36 VDC isolated;
incl. external AC power supply
90 to 264 VAC
90 to 264 VAC
Add internal buffer battery
for ~ 2 min. operation
Redundant AC power supply
n/a
Battery powered, 4 battery slots
for ~2 hours operation
n/a
n/a
441 x 427 x 177 mm
(4 u plus 1 u for cooling in cabinet required)
(17.4 x 16.8 x 7 in.) without feet
Typ. 7.3 kg (16 lb.)
Typ. 13 kg (28.6 lb.)
Software
441 x 230 x 177 mm
(4 u plus 1 u for cooling in cabinet required)
(17.4 x 9.1 x 7 in.) without feet
CVT Logger
CPAD2 via TRION-CAN
120 GB Solid State Disk
Dedicated Instruments
EPAD2 or CPAD2 via TRION-CAN
Front-ends
DEWE2-M13s
MOB-DISP-12
External display
DEWE2-M13s with 4 battery
slots
DEWE2-M13 with 2x option
DW2-M13-BAY35-SATA
13
Front-ends
Most compact and flexible configuration
High-end A/D conversion
Data transmission via PCIe (up to 7 m) or fibre-optic
Slots for TRION™ acquisition modules
DEWE2-F4s
DEWE2-F7s
DEWE2-F13s
4
7
13
High-speed channel expansion
DEWE2-F13-FIBRE
DEWE2-F18
13
18
Firbre-optic
(needs fibre-optic
card in host)
PCIe
Daisy-chain another Front-end chassis
Low-speed channel expansion 100 Hz
CPAD3 via TRION-CAN
Quasi-static channel expansion
CPAD2 via TRION-CAN (no EPAD)
Interface to host
PCIe
Power Supply
Power supply standard (max.)
90 to 264 VAC
Option 1
max. 10 to 36 VDC
isolated
max. 10 to 36 VDC
isolated
Redundant AC power
supply
Redundant AC power
supply
Redundant AC power
supply
Option 2
Add internal buffer
battery
for ~ 5 min. operation
(requires DC option)
Add internal buffer
battery
for ~ 5 min. operation
(requires DC option)
max. 10 to 36 VDC
isolated;
Additional buffer
battery
for ~ 2 min. operation
n/a
n/a
Option 3
n/a
n/a
Battery powered,
4 battery slots1)
for ~2 hours operation
n/a
n/a
Dimensions (W x D x H)
(without feet)
177 x 230 x 177mm
(4 u)
(7 x 9.1 x 7 in.)
258 x 230 x 177 mm
(4 u)
(10.2 x 9.1 x 7 in.)
441 x 230 x 177 mm
(4 u)
(17.4 x 9.1 x 7 in.)
441 x 427 x 177 mm
(4 u)
(17.4 x 16.8 x 7 in.)
441 x 427 x 177 mm
(4 u)
(17.4 x 16.8 x 7 in.)
Weight without modules and batteries1)
Typ. 3.9 kg (8.6 lb.)
Typ. 4.9 kg (10.8 lb.)
Typ. 8 kg (17.6 lb.)
Typ. 12 kg (26.4 lb.)
Typ. 12 kg (26.4 lb.)
Dimensions
1)
Weight of one battery: 660 g (1.45 lb.)
LINK-HOST-EX34
ExpressCard-34 host card
14
DEWE-DCDC-24-300-ISO
DEWE2-F13s with option
DW2-PS-AC-RED
www.de we t ron .com
Network with multiple systems
WLAN
DEWE2-A4
with TRION-BASE module
DEWE2-M7s
with TRION-BASE module
Sync up to 1000 meters (IRIG DC, cable length delay compensation)
GPS-SYNC
GPS
Two or more instruments
synchronized via GPS
TRION Systems
ORION Systems
DEWE2-F13-FIBRE with
TRION-TIMING module
Front-ends
IRIG-SYNC
CVT Logger
DEWE2-M13
with TRION-TIMING module
Dedicated Instruments
50 m Fibre link for data transfer
Software
Example: DEWE2-M13 expanded with DEWE2-F13-FIBRE via fibre-cable for long distance
About us
Distributed systems over large distance
15
ORION A/D Boards
Simultaneous sampling with separate A/D converter per channel
Clock output for synchronizing external devices, e.g. cameras
Synchronized analog, digital, counter and CAN inputs
Model overview
Analog
input
channels
Input ranges
Resolu
tion
Max. sampling rate /
channel
Type of ADC
Digital
input
channels
Digital I/O
Counter /
Encoder
CAN
DEWE-ORION-0824-20x series
8
Voltage: ±0.1 V, ±0.5 V, ±2 V, ±10 V
IEPE®: 4 mA / 8 mA excitation
24 bit
204.8 kS/s
delta-sigma
with antialising
filter
up to 40
8
up to 10
(advanced)
up to 2
DEWE-ORION-0816-100x series
8
Voltage: ±1.25 V, ±2.5 V, ±5 V, ±10 V
16 bit
1 MS/s
successive
approximation
(SAR)
up to 40
8
up to 10
up to 2
DEWE-ORION-0816-5Mx series
8
Voltage: ±5 V
16 bit
5 MS/s
successive
approximation
(SAR)
up to 8
8
2
(advanced)
up to 2
DEWE-ORION-0816-10Mx series
8
Voltage: ±5 V
16 bit
10 MS/s
successive
approximation
(SAR)
up to 8
8
2
(advanced)
up to 2
DEWE-ORION-1624-20x series
16
Voltage: ±10 V
24 bit
204.8 kS/s
delta-sigma
with antialising
filter
up to 40
8
up to 10
(advanced)
up to 2
DEWE-ORION-1622-10x series
16
Voltage: ±10 V
22 bit
102.4 kS/s
delta-sigma
with antialising
filter
up to 40
8
up to 10
(advanced)
up to 2
DEWE-ORION-1616-10x series
16
Voltage: ±1.25 V, ±2.5 V, ±5 V, ±10 V
16 bit
100 kS/s
successive
approximation
(SAR)
up to 40
8
up to 10
up to 2
DEWE-ORION-1616-100x series
16
Voltage: ±1.25 V, ±2.5 V, ±5 V, ±10 V
16 bit
1 MS/s
successive
approximation
(SAR)
up to 40
8
up to 10
up to 2
DEWE-ORION-3222-10x series
32
Voltage: ±10 V
22 bit
102.4 kS/s
delta-sigma
with antialising
filter
up to 24
8
2
(advanced)
up to 2
DEWE-ORION-3216-10x series
32
Voltage: ±1.25 V, ±2.5 V, ±5 V, ±10 V
16 bit
100 kS/s
successive
approximation
(SAR)
up to 24
8
2
up to 2
Options and Accessories
DEWE-ORION-xxxx
with additional digital
inputs
16
DEWE-CAN-CAB2 option
Connects the built in Lemo
conn. with your D-Subs
ORION-CAN-PANEL
9-pin D-Sub connectors for
CAN channel 0 and 1
ORION-xxxx-SYNC option
Synchronization with PC
based instruments
Built-in digital I/O and
counter/encoder
connectors (option)
www.de we t ron .com
About us
High-speed Amplifiers
Selectable filters and multiple ranges
Analog signal output (±5 V)
Module
Bandwidth (BW),
Isolation (ISO),
TEDS Filters (LP = lowpass, Overvoltage
HP = highpass)
protection (OP)
Input type
Ranges
Strain gauge, bridge sensors
±0.1 to ±1000 mV/V (@ 5 VDCexc)
BW: up to 2 MHz
ISO: 350 VDC
Piezoresistive bridge
±0.5 to 10000 mV/mA (@ 1 mAexc)
LP: 100 Hz to 2 MHz
OP: ±50 VDC
Voltage
±500 µV to ±10 V
HP: 1 Hz
Resistance
25 mΩ to 100 kΩ
Pt100, Pt200, Pt500, Pt1000,
-200° C to 850° C
Universal measurement
HSI-STG
V

MSI
Charge via MSI-BR-CH-50
up to 50000 pC
Voltage via MSI-BR-V-200
up to ±200 V
High voltage
±20 to ±1400 V
High voltage measurement
HSI-HV
-
BW: 2 MHz
ISO: 1.8 kVRMS
LP: 100 Hz to 2 MHz
V
Voltage & current measurement
HSI-LV
V
MSI
MSI
Voltage
±10 mV to ±50 V
Current with external shunt
20 mA / 5 A
IEPE® via MSI-V-ACC
±10 mV to 5 V
Pt100, Pt200, Pt500, Pt1000,
-200° C to 1000° C and
Pt2000 and resistance via
8 to 4 kΩ
MSI-V-RTD

BW: 2 MHz
LP: 100 Hz to 2 MHz
ISO: up to
1 kVRMS
OP: 350 VDC
Dedicated Instruments
MSI
Software
±100 to ±10000 mV
Thermocouple via MSI-BR-TH-x full range of TC type
CVT Logger
Pt2000
IEPE® via MSI-BR-ACC
MSI
ORION Systems
Front-ends
High bandwidth up to 2 MHz
TRION Systems
Isolated single channel module
17
SelectionAmplifiers
Guide
Dynamic
DAQ Series Modules
Isolated dynamic single channel module
Single
High isolation
channelup to 1.8 kV RMS
High bandwidth -up
300 kHzsignals
fortodynamic
(mostvia
models)
Isolation
Configuration
RS-485 interface
Analog signal output (±5 V)
Pure signal conditioning solution in conjunction with DEWE-30 series racks
Module
Input type
Ranges
Bandwidth (BW),
Isolation (ISO),
TEDS Filters (LP = lowpass, Overvoltage
HP = highpass)
protection (OP)
Universal measurement
DAQP-STG
V
Strain gauge, bridge sensors
±0.1 to ±1000 mV/V (@ 5 VDCexc)
Piezoresistive bridge
±0.5 to 10000 mV/mA (@ 1 mAexc)
Voltage
±500 µV to ±10 V
Resistance
25 mΩ to 100 kΩ
Pt100, Pt200, Pt500, Pt1000,
-200° C to 850° C

BW: 300 kHz
ISO: 350 VDC
LP: 10 Hz to 300 kHz
OP: ±50 VDC
Pt2000
IEPE® via MSI-BR-ACC
±100 to ±10000 mV
Thermocouple via MSI-BR-TH-x full range of TC type
MSI
MSI
MSI
DAQP-MULTI
V
Charge via MSI-BR-CH-50
up to 50000 pC
Voltage via MSI-BR-V-200
up to ±200 V
Thermoresistors
Pt100, Pt200, Pt500, Pt1000 and
Pt2000, free programmable range
Thermocouple
Type K, J, T, R, S, N, E, B, L, C, U
free programmable range
Resistance
1 Ohm to 1 MOhm
Piezoresistive bridge
Voltage
Current (with external shunt)
13 ranges (±0.5 to 5000 mV/mA)
10 ranges from ±5 mV to ±5 V
depending on external shunt
High voltage
±20 to ±1400 V

ISO: 1 kVRMS
BW: 3 kHz
LP: 3, 10, 30, 100, 300,
1000 Hz
High voltage measurement
DAQP-HV
-
V
BW: 300 kHz
ISO: 1.8 kVRMS
LP: 10 Hz to 300 kHz
Voltage & current measurement
DAQP-LV
V
MSI
DAQN-AIN
V
18
MSI
MSI
Voltage
±10 mV to ±50 V
Current with external shunt
20 mA / 5 A
IEPE® via MSI-V-ACC
±10 mV to 10 V
Pt100, Pt200, Pt500, Pt1000,
-200° C to 1000° C and
Pt2000 and resistance via
0 to 6.5 kOhm

LP: 10 Hz to 300 kHz
ISO: up to
1 kVRMS
OP: 350 VDC
-
OP: < ±500 V
BW: 300 kHz
MSI-V-RTD
Charge via MSI-V-CH-50
up to 50000 pC
Voltage
±10 V (1:1 input)
-
(jumper
selectable)
www.de we t ron .com
DAQP-LA-B
Current
0.1 A to 30 A peak
Note: 5 ARMS continuous
max. 5 ARMS contin. current
-
Current
2 mA to 600 mA
BW: 300 kHz
ISO: 1.4 kVRMS
LP: 10 Hz to 300 kHz
-
Note: typ. 20 mA application
BW: 300 kHz
ISO: 1.4 kVRMS
LP: 10 Hz to 300 kHz
Carrier frequency amplifier
DAQP-CFB2
AC bridge, strain gauge
Bridge: 0.1 to 1000 mV/V
-
Note: programable sine wave
excitation up to 20 kHz
BW: DC to 9.6 kHz
OP: ±10 VDC
LP: 10 Hz to 1 kHz
Inductive sensors,
LVDTcapacity
Inductive: 5 to 1000 mV/V
Capacity
20 pF to 1 µF
IEPE® sensors
±50 mV to ±5 V
Charge / IEPE® measurement
DAQP-ACC-A
-
BW: 0.5 Hz to 300 kHz LP: 1 to 300 kHz
HP: 0.5 Hz and 5 Hz
DAQP-CHARGE-A
Charge sensors
Charge: 5 to 50000 pC
IEPE® sensors
IEPE®: ±5 mV to 5 V
-
Charge sensors
-
LP: 100 Hz to 50 kHz
HP: 0.1 Hz to 10 Hz
Note: selectable integration and
double integration
DAQP-CHARGE-B
BW: 0.1 Hz to 50 kHz
±100 to ±1 000 000 pC
-
BW: DC to 100 kHz
ISO: 350 VDC
LP: 10 Hz to 100 kHz
HP: DC, 0.001 Hz to
0.5 Hz
Note: selectable time constant
for static sensors
Temperature measurement
DAQP-THERM
Thermocouple
Type K, J, T, R, S, N, E, B, L, C and
U selectable
Note: internal CJC and
linearisation
free programmable range
Frequency
100 Hz to 200 kHz
-
BW: 3 kHz
ISO: 1 kVRMS
LP: 3, 10, 30, 100, 300,
1000 Hz
Frequency measurement
DAQP-FREQ-A
-
About us
DAQP-LA-SC
TRION Systems
Current measurement
ORION Systems
Bandwidth (BW),
Isolation (ISO),
TEDS Filters (LP = lowpass, Overvoltage
HP = highpass)
protection (OP)
Ranges
BW: according to range ISO: 350 VDC
Output response:
1.5 ms
30 ms
500 ms
Front-ends
Input type
CVT Logger
Module
Voltage output
1:1 output module with isolation
-
BW: 400 Hz
ISO: 240 VDC
Input voltage: ±10 V
Output voltage: ±10 V
OUT
ADAP-D9M-BNCF:
DSUB to BNC adapter
for DAQP-V series and
DAQP-FREQ modules
BNC to Microdot adapter
CONN-DSUB-9:
(included as a standard with Screw terminal adapter
DAQP-CHARGE-A modules) for all modules with 9-pin
DSUB connector
BNC to banana and
banana to BNC adaptors
Isolated high-voltage amplifier: DAQP-HV
Software
DAQN-V-OUT
Dedicated Instruments
Voltage output module
19
Differential Amplifiers
Multi-channel differential amplifiers
Small form factor for high channel density
Cost effective
Support of MSI (Modular Smart Interface)
SUB Modules for MDAQ-BASE-x
#
Input type
CH
Module
MDAQ-SUB-STG-D
8
Connector: DB-9
Ranges
Strain-gage (Full-, half and quarterbridge, incl. shunt calibration)
for strain gage application
MSI
V
MSI
MSI
MDAQ-SUB-V-200-D
8
Connector: DB-9
V
MSI
14 ranges from ±0.5 to 1000
mV/V (@ 5 VDC excitation
Voltage up to ±10 V
15 ranges from ±2.5 mV to ±10 V
ICP via MSI-BR-ACC
7 ranges from ±0.25 mV to ±10 V
Voltage up to 200 V via MSI-BR-V-200
6 ranges from ±10 to ±200 V
Thermocouple via MSI-BR-TH-x
full range of TC type
Pt100, Pt200, Pt500, Pt1000, Pt2000
-200 °C to 1000 °C
and resistance via MSI-BR-RTD
and 0 to 6.5 kOhm
Voltage up to ±200 V
13 ranges from ±0.125 to ±200 V
ICP, via MSI-V-ACC
7 ranges from ±0.25 mV to ±10 V
Pt100, Pt200, Pt500, Pt1000, Pt2000
-200 °C to 1000 °C
and resistance via MSI-V-RTD
and 0 to 6.5 kOhm
Bandwidth (BW),
Excitation
Highpass filters (HP)

BW: 30 kHz

BW: 300 kHz
0 to 12 VDC
±15 VDC and
0 to 12 VDC
Note:
for safety reasons, max. 120 VDC or 50 VAC are allowed at this connector
MSI
MDAQ-SUB-V-200-BNC
TEDS
8
Voltage up to ±200 V
13 ranges from ±0.125 to ±200 V
-
BW: 300 kHz
-

BW: 300 kHz
4 / 8 mA
Connector: BNC
V
MDAQ-SUB-ACC-BNC
Note:
for safety reasons, max. 120 VDC or 50 VAC are allowed at this connector
8
ICP® or voltage up to ±10 V
8 ranges from ±125 mV to ±10 V
Connector: BNC
HP: 3.4 Hz
Single-ended or differential input and one highpass filter
3.4 Hz highpass filter for noise and shock response measurement
MDAQ-SUB-ACC-A-BNC
Connector: BNC
8
MDAQ-SUB-ACC-BNC-S1
0,16 Hz for structural and modal analysis, human body vibration
measurement (rest same as MDAQ-SUB-ACC-BNC)

ICP® or voltage up to ±10 V

MDAQ modules - available in most of the
DEWETRON multichannel systems.
20
8 ranges from ±125 mV to ±10 V
Single-ended input and two HP filters
0.16 Hz for structural and modal analysis, human body vibration
measurement
3.4 Hz for noise and shock response measurement
DEWE-51-USB2-32
2x MDAQ-SUB-BRIDGE-D,
2x MDAQ-SUB-ACC-A modules and USB-A/D converter
BW: 300 kHz
4 / 8 mA
HP: 0.16 Hz
BW: 300 kHz
4 / 8 mA
HP: 0.16 Hz, 3.4 Hz
Typical combination with
two SUB modules mounted
on a BASE module, and
FILTER board (optional)
All MDAQ boards are
equipped with highest quality components
www.de we t ron .com
# CH
16
Filter characteristics
Butterworth
Cut-off frequencies
100 Hz, 1, 10, 30, 100 kHz, Bypass
Order
th
4
Note:
not possible in all system configurations.
Please contact factory for details.
16
Butterworth
30, 100, 300 Hz, 1, 10 kHz, Bypass
2
MDAQ-FILT-5-BU-S1
16
Butterworth
100 Hz, 1, 10, 30, 100 kHz, Bypass
2
MDAQ-FILT-5-BE
16
Bessel
30, 100, 300 Hz, 1, 10 kHz, Bypass
2
TRION Systems
nd
MDAQ-FILT-5-BU
nd
MDAQ-SUB-V-200-D
DAQP-STG-D
DAQP-LV-D
HSI-LV

-

-
-
Isotron (constant current powered) adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
Excitation current 4 mA at 21 V, High pass filter 1.5 Hz, BNC connector
Bandwidth and ranges are defined by connected amplifier
Automatic adapter identification
-


-
-
200 V input adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
Differential input configuration, BNC connector
Bandwidth and ranges are defined by connected amplifier
Automatic adapter identification
MSI-BR-RTD
-

not needed
-
-
Pt100, Pt200, Pt500, Pt1000 and Pt2000 adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
2, 3 and 4 wire connection methods, 5-pin Binder 712 series connector
Automatic adapter identification
MSI-BR-CH-x
-


-
-
Charge input interface for DAQP-STG and MDAQ-SUB-BRIDGE / -STG with DB9 connector
Range up to 50000 pC, AC coupled with 0.07 Hz, BNC signal connection
Max. 100 kHz bandwidth (dependent on the max. bandwidth of the amplifier)
Automatic adapter identification
MSI-BR-TH-x
-


isolated TC sensor
-
-
any TC sensor
Thermocouple type K / J / T adapter for DAQP-BRIDGE-x and MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
For use with isolated thermocouple sensors only ! (except in combination with DAQP-BRIDGE-A*)
High accuracy cold junction reference measurement, 1 m thermo cable with Mini TC connector
Automatic adapter identification
MSI-V-ACC
-

-


Isotron (constant current powered) adapter for DAQP-LV and MDAQ-SUB-V-200 modules with DB9 connector
Excitation current 4 mA at 21 V, High pass filter 1.5 Hz, BNC connector
Bandwidth and ranges are defined by connected amplifier
Automatic adapter identification
MSI-V-RTD
-

-


Software
MSI-BR-V-200
CVT Logger
MDAQ-SUB-STG-D
Dedicated Instruments
Modular Smart Interfaces for HSI, DAQP and MDAQ modules
Front-ends
ORION Systems
nd
MSI Series
MSI-BR-ACC
About us
Filter modules for MDAQ
Module
MDAQ-AAF4-5-BU
Pt100, Pt200, Pt500 and Pt1000 adapter for DAQP-LV and MDAQ-SUB-V-200 modules with DB9 connector
2, 3 and 4 wire connection methods, 5-pin Binder 712 series connector
Automatic adapter identification
21
All-in-one ORION
Built-in display
Powerful PC inside for fast online displays and analysis
Most convenient for mobile applications
DEWE-2600
DAQ / PAD amplifier slots
MDAQ amplifier input channels
DEWE-5000
16
16
Up to 80
Up to 32
Combined DAQ / PAD slots
16 DAQ / PAD
and MDAQ input channels
up to 32 MDAQ
Total PCI slots
Available with DAQ / PAD slots
7
5
4
5
High-speed channel expansion
Low-speed channel expansion 100 Hz
DEWE-50-PCI Front-end or DEWE-30
CPAD3, requires CAN interface in base unit
Quasi-static channel expansion
EPAD2
Data storage
1 TB hard disk
Optional data storage
Display
n/a
Up to 480 GB SSD
15“ (1280 x 1024)
17“ (1920 x 1080)
FULL HD
Power supply
Standard rated (max.)
Option
95 to 260 VAC
95 to 260 VAC
Battery powered, 3 battery slots for ~2 hours operation
Dimensions
Dimensions (W x D x H)
417 x 246 x 303 mm
(16.4 x 9.6 x 11.9 in.)
460 x 351 x 192 mm
(18.1 x 13.8 x 7.7 in.)
Weight without batteries1)
Typ. 14 kg (31 lb.)
Typ. 17 kg (37.4 lb.)
1)
Weight of one battery: 660 g (1.45 lb.)
DEWE-2600 shipping and carrying case
22
DEWE-5000 with batteries
DEWE-2600 car seat mounting kit
www.de we t ron .com
DEWE-571
-
Up to 32
Up to 16
Up to 16
n/a
2
1
1
1
n/a
n/a
DEWE-30
n/a
DEWE-50-PCI Front-end or DEWE-30
CPAD3, requires CAN interface in base unit
EPAD2
120 GB Solid State Disk
120 GB Solid State Disk
Up to 1 TB SSD
Up to 480 GB SSD
Up to 480 GB SSD
15“ multitouch-screen (1280 x 800)
13“ (1280 x 800)
12“ touchscreen (1280 x 800)
95 to 260 VAC
8 to 30 VDC,
incl. external AC power supply
Battery powered, 2 battery slots,
2 batteries for ~2 hours operation incl.,
incl. external AC power supply
8 to 30 VDC
incl. external AC power supply
DEWE-UPS-150-DC
(ext. battery pack, 2 battery slots)
n/a
462 x 320 x 135 mm
(18.2 x 12.6 x 5.3 in.)
317 x 252 x 110 mm
(12.5 x 9.9 x 4.3 in.)
360 x 300 x 150 mm
(14.2 x 11.8 x 5.9 in.)
Typ. 8.2 kg (18 lb.)
Typ. 5.5 kg (12.1 lb.)
Typ. 5 kg (11 lb.)
Software
1 TB hard disk
Front-ends
-
CVT Logger
DEWE-1201
16
Dedicated Instruments
DEWE-3300
ORION Systems
TRION Systems
About us
All-In-One
DW2-UPS-150-DC,
130 W UPS with 2 slots for batteries
DEWE-2600 customized version
DEWE-POW-24-350
23
Mainframes ORION
Portable and rack-mount versions
Powerful PC inside for fast online data view & analysis
Many power supply options
DEWE-800 series
DEWE-510 series
DAQ / PAD amplifier slots
16
MDAQ amplifier input channels
Combined DAQ / PAD slots
and MDAQ input channels
Total PCI slots
Available with DAQ / PAD slots
Up to 64
n/a
16 DAQ / PAD,
up to 32 MDAQ (BNC only)
5
3
5
High-speed channel expansion
Low-speed channel expansion 100 Hz
Quasi-static channel expansion
3
DEWE-50-PCI Front-end or DEWE-30
CPAD3, requires CAN interface in base unit
EPAD interface with up to 16 EPAD2 modules = 128 ch
Data storage
1 TB hard disk
Optional data storage
Up to 480 GB SSD
Power supply
Standard (max.)
95 to 260 VAC
9 to 18 VDC
or
18 to 36 VDC
Battery powered, 3 battery slots 3),
2 batteries for ~2 hrs. operation incl.,
incl. external AC power supply
optional external DC power supply
Dimensions (W x D x H)
437 x 443 x 181 mm (17.2 x 17.4 x 7.1 in.)
439 x 308 x 181 mm (17.2 x 12.1 x 7.1 in.)
Weight without batteries1)
Typ. 12 kg (26.4 lb.)
Typ. 8 kg (17.6 lb.)
Optional
Dimensions
1)
Weight of one battery: 660 g (1.45 lb.)
DEWE-800 with 19” mounting kit
24
POWERBOX-12
Power distribution for automotive applications
DEWE-DCDC-24-300-ISO
10 to 36 VDC power supply 24 VDC (300 W)
www.de we t ron .com
Megawattlabor am Fraunhofer ISE, Freiburg ©Fraunhofer ISE
DEWE-501 series
ORION Systems
TRION Systems
About us
Mainframes
DEWE-211 series
n/a
n/a
3
1
n/a
n/a
Setup network
CPAD3, requires CAN interface in base unit
EPAD interface with up to 16 EPAD2 modules = 128 ch
120 GB Solid State Disk
Up to 480 GB SSD
8 to 30 VDC,
incl. external AC power supply
External DC power supply
Stackable battery-pack for ~2 hrs.
operation with wide range DC input
439 x 209 x 181 mm (17.2 x 8.2 x 7.1 in.)
317 x 252 x 92 mm (12.4 x 9.9 x 3.6 in.)
Typ. 6 kg (13.2 lb.)
Typ. 5 kg (11 lb.)
Software
Battery powered, 2 battery slots 3),
2 batteries for ~2 hrs. operation incl.,
incl. external AC power supply
CVT Logger
Front-ends
Up to 16
Dedicated Instruments
Up to 64
Battery charger BAT-CHARGER-1
(range: 90 to 260 VAC)
Battery charger BAT-CHARGER-4
(range: 90 to 260 VAC)
The carrying bag is included
as standard accessory
25
PCI Front-ends ORION
High speed PCIe connection to your computer or laptop
Up to 128 ch per chassis
Cascading option for creating high channel count systems
DEWE-50-PCI-16
DEWE-50-PCI-32
DEWE-51-PCI-64
Slots for DAQ or PAD modules
16
32
n/a
n/a
MDAQ input channels
n/a
n/a
Up to 64
Up to 128
External quasi-static channel expansion
DEWE-51-PCI-128
EPAD interface, up to 16 EPAD2 modules = 128 ch
Digital I/O, counter, CAN bus
Depending on selected ORION board(s)
Main system
Internal PCI slots
1
Host PC interface
3
Supported operating systems
Power supply (max.)
Dimensions (W x D x H)
Weight
7
13
ExpressCard-54, optional PCI, PCI-Express or ExpressCard-34
Microsoft® WINDOWS® 7
95 to 260 VAC
95 to 260 VAC
95 to 260 VAC
95 to 260 VAC
435 x 245 x 133 mm
(17.1 x 9.6 x 5.2 in.)
435 x 300 x 223 mm
(17.1 x 11.8 x 8.8 in.)
435 x 300 x 177 mm
(17.1 x 11.8 x 7.0 in.)
435 x 300 x 267 mm
(17.1 x 11.8 x 10.5 in.)
Typ. 6 kg (13 Ibs)
Typ. 10 kg (22 Ibs)
Typ. 6 kg (13 Ibs)
Typ. 9 kg (20 Ibs)
Environmental specifications
Operating temperature
0 to +50 °C
Storage temperature
-20 to +70 °C
Humidity
10 to 80 % non cond., 5 to 95 % rel. humidity
Vibration
EN 60068-2-6, EN 60721-3-2 Class 2M2
Shock
EN 60068-2-27
The use of multiple DEWE-50-PCI on a single notebook is supported;
ending up in a very flexible multi-channel system
26
Easy PCI connection with laptop computers
www.de we t ron .com
About us
USB & Ethernet Front-ends
Easy USB or Ethernet connection to your computer
DEWE-50-USB2-16
DEWE-50-NET-16
8
16
16
EPAD interface, up to 8 EPAD2
modules = 64 ch
EPAD interface, up to 16 EPAD2 modules = 128 ch
A/D conversion
Sampling method
Resolution
Sampling rate
Simultanous sampling
Multiplexed sampling
24 bit
16 bit
Multiplexed sampling
16 bit
204.8 kS/s
500 kS/s aggregate
31.25 kS/s per channel
500 kS/s aggregate
31.25 kS/s/ch @ 16 AI
29.41 kS/s/ch @ 16AI + DI
26.31 kS/s/ch @ 16AI + DI + 1 counter
18.51 kS/s/ch @ 16 AI + DI + 5 counter
2 counters or 6 digital inputs
Optional
5 isolated counters / 16 TTL level DI
2
-
-
9 to 36 VDC
95 to 260 VAC
85 to 264 VAC
Counter and digital inputs
Counters / digital inputs
CAN bus
High-speed CAN bus interfaces
Power supply
Standard (max.)
Main system
Host PC interface
Supported operating systems
Dimensions (W x D x H)
Weight
USB 2
USB 2
100 Mbit Ethernet
Microsoft® WINDOWS® 7
Microsoft® WINDOWS® 7
Microsoft® WINDOWS® 7 / 8
230 x 181 x 104 mm
9.1 x 7.1 x 4.1 in.
435 x 245x 133 mm
17.1 x 9.6 x 5.2 in.
435 x 245 x 133 mm
(17.1 x 9.6 x 5.2 in.)
Typ. 3 kg (6.6 lbs)
Typ. 5.5 kg (12 Ibs)
Typ. 5.5 kg (12 Ibs)
Environmental specifications
Operating temperature
0 to +50 °C
Storage temperature
-20 to +70 °C
Relative humidity
5 to 95 % rel. humidity (10 to 80 % non cond.)
Vibration
EN 60068-2-6, EN 60721-3-2 class 2M2
EN 60068-2-27
Software
Shock
Front-ends
External quasi-static
channel expansion
DEWE-50-USB2-8
CVT Logger
Slots for DAQ or PAD modules
Dedicated Instruments
Various power supply options
ORION Systems
TRION Systems
Sync option for channel expansion (some models)
Carrying handle
DEWE-50-DC option for DC
power supply
USB interface with hot
plug-and-play capabilities
16 BNCs on the rear for
conditioned signal output
19“ rack mount kit
27
CPAD3
*)
100 Hz sampling rate
High isolation 1500 V
ADC per channel
Module
CPAD3-TH8-x
CPAD3-V8
Input type
Dedicated modules
for type J, K, T
Universal module for types
K, J, T, E, R, S, B, N, C, U
8 isolated voltage input
channels
Input ranges
According
thermocouple type
Isolation
1500 VDC (channel to
channel and channel to
BUS, power and
chassis)
Special
Overvoltage
protection:
15 VDC
Physical input range: ±50 V
Software selectable:
±100 mV, ±500 mV, ±1 V,
±2.5 V, ±5 V, ±10 V
1500 VDC (channel to
channel and channel to
BUS, power and
chassis)
Overvoltage
protection:
350 VDC
CPAD3-TH8-x
Intelligent amplifier with integrated A/D conversion
CAN interface
8 input channels for thermocouples
Available thermocouple types:
CPAD3-TH8-x: K, J, T standard type
CPAD3-TH8-UNIVERSAL: Universal type
CPAD3-V8
Intelligent amplifier with integrated A/D conversion
CAN interface
8 isolated voltage input channels
CPAD3-V8 LEMO version
* CPAD = CAN-Bus interface
28
* EPAD = RS-485 interface
www.de we t ron .com
About us
*)
Extremely rugged and flexible mounting
Input ranges
According
thermocouple type
Isolation
350 VDC (channel to
channel and channel to
BUS, power and
chassis)
Special
Overvoltage
protection:
15 VDC
Overvoltage
protection:
350 VDC
EPAD2/CPAD2-V8
8 isolated voltage input
channels
Physical input range: ±50 V
Software selectable:
±100 mV, ±500 mV, ±1 V,
±2.5 V, ±5 V, ±10 V
350 VDC (channel to
channel and channel to
BUS, power and
chassis)
EPAD2/CPAD2-RTD8
8 isolated Resistance Temperature Detector channels
Resistor: 0 to 999.99 Ω
RTD: PT100(385), PT200
(385), PT500(385), PT1000
(385), PT2000(385), PT100
(3961)
350 VDC (channel to
channel and channel to
BUS, power and
chassis)
EPAD2/CPAD2-LA8
8 isolated current inputs
0 to 20 mA, ±20 mA, ±30 mA
EPAD2-USB
USB-interface module
for EPAD2
n/a
Module
EPAD2-AO4
Output type
4 voltage or current output
channels
Output ranges
±10 V; ±5 V; 0 to 5 V; 0 to
10 V;
0 to 20 mA; 4 to 20 mA
Overvoltage
protection:
15 VDC
350 VDC (channel to
channel and channel to
BUS, power and
chassis)
Overcurrent
protection:
70 mA cont.
-
-
Isolation
Special
350 VDC (channel to BUS,
power and chassis)
-
Front-ends
Input type
Dedicated modules
for type J, K, T
Universal module for types
K, J, T, E, R, S, B, N, C, U
CVT Logger
Module
EPAD2/CPAD2-TH8-x
Dedicated Instruments
Channel to channel/system isolation
ORION Systems
TRION Systems
24 bit A/D converter per channel, 12 Hz sampling rate
Software
EPAD2/CPAD2
29
CVT Logger
USB data logger for current, voltage and temperature inputs
Touch operation and easy to use software
8 to 40 channels, 24 bit, up to 12 Hz
Packages
Each package contains: CVT Logger software, interface module, and power supply (24 V). EPAD modules of your
choice must be selected (bricks of 8 channels). Depending on application, CVT Logger is delivered stacked, or
separated for distributed measurements. For distributed systems cable length between the modules can be selected
(2 m, 5 m, 10 m).
Package
EPAD modules
Input channels
CVT-Logger 8
1
8
CVT-Logger 16
2
16
CVT-Logger 24
3
24
CVT-Logger 32
4
32
CVT-Logger 40
5
40
EPAD modules
Module
Input type
Input ranges
Isolation
Universal module for types K,
J, T, E, R, S, B, N, C, U
According
thermocouple type
350 VDC
(channel to channel and channel to BUS,
power and chassis)
8 isolated Resistance
Temperature Detector channels
Resistor: 0 to 999.99 Ω
RTD: PT100(385),
PT200 (385), PT500(385), PT1000
(385), PT2000(385), PT100 (3961)
350 VDC
(channel to channel and channel to BUS,
power and chassis)
8 isolated current inputs
0 to 20 mA, ±20 mA, ±30 mA
0 to 20 mA, ±20 mA, ±30 mA
8 isolated voltage input
channels
Physical input range: ±50 V
Software selectable:
±100 mV, ±500 mV, ±1 V, ±2.5 V,
±5 V, ±10 V
350 VDC
(channel to channel and channel to BUS,
power and chassis)
EPAD2/CPAD2-TH8-x
EPAD2/CPAD2-RTD8
EPAD2-LA8
EPAD2/CPAD2-V8
30
www.de we t ron .com
About us
Power Network Analyzers
DEWE-638-PNA
DEWE-838-PNA-P
4 voltage
4 current (up to 12)
4 voltage
28 current
4 voltage
4 current
4 voltage
4 current
-
-
-
-
Signal conditioning
Current clamps / coils included
External quasi-static channel expansion
Internal
4x PNA-FLEX-300-45
-
Option PAD-BOX
Input specifications
Voltage range
±1400 V peak
Bandwidth of input amplifiers
DC to 300 kHz
Direct current input
5A
Maximum input current via clamps
Depending on clamps
-
10000 A
-
Maximum input current via flexible coils
A/D conversion
Sampling rate
571/561-PNA: 250 kS/s aggregate
571/561-PNA-1MS: 1 MS/s/ch
1 MS/s aggregate
10 kS/s
10 kS/s
3
opt. 2
-
-
Solid State Disk
SD Card
Solid State Disk
120 GB
2 GB
2 GB
Resolution
16 bit
Digital I/O
Digital I/O, TTL level
2x DIN (24 V max.) and 1x DOUT
(Relais, normal open, 60 V / 1 A AC max.)
Functions
Accuracy classification
Wide band power analysis
IEC 61000-4-30 Class A
DEWE-571-PNA-1MS: 1 MS/s
-
Data storage 1)
Technology
Capacity
Main system 1)
Display
12“ TFT (1280 x 800) touch
Processor
Intel® Core™ i5
Interfaces
2x USB, 1x Ethernet,
1x RS-232
-
-
Low power CPU
1x USB, 1x Ethernet,
1x RS-232
1x USB, 2x Ethernet,
1x RS-232
Power supply
Standard
Version 571-PNA: Battery powered, 2 battery slots 2),
85 to 265 VAC 50 / 60 Hz 95 to 260 VAC 50 / 60 Hz
2 batteries for ~2 hrs. operation incl., incl. external AC power supply
internal 10 - 36 VDC
(internal 10 to 36 VDC)
Version 561-PNA: 95 to 260 VAC 50 / 60 Hz
Dimensions
Dimensions (W x D x H)
360 x 300 x 150 mm
(14.2 x 11.8 x 5.9 in.)
200 x 150 x 75 mm
(7.9 x 5.9 x 3 in.)
160 x 166 x 125 mm
(6.2 x 6.5 x 4.9 in.)
Weight without batteries
Typ. 5 kg (11 lb.)
Typ. 2.5 kg (5.5 lb.)
Typ. 2 kg (4.4 lb.)
1)
Front-ends
DEWE-561-PNA-4U28I
CVT Logger
Dynamic analog input channels
DEWE-571-PNA
Dedicated Instruments
Power rating, harmonics (including 2-9 kHz),
interharmonics, Flicker, symmetrical components,
frequency, DISDIP/Unipede statistics, CBEMA/ITIC curve
Software
IEC61000-4-30 Class A
ORION Systems
TRION Systems
EN50160
Please find current specifications in the latest price list 2) Weight of one battery: 660 g (1.45 lb.)
31
Power Fault Recorders
Monitoring of power supply systems
Power plant testing and monitoring
High, medium and low voltage systems
Fault recording, harmonics, flicker, power flow, DIP measurements, database storing
GPS synchronisation, remote control, EN50160, ITIC (CBEMA), UNIPEDE
Dynamic analog input channels
DEWE-818-PFR
DEWE-821-PFR
DEWE-820-PFR-16
DEWE-838-PNA-V
Up to 48 voltage or current
with DEWE-30-16-PFR
Up to 12 voltage
and 12 current
16 slots for
DAQP modules
3 voltage
Ext. quasi-static channel expansion
EPAD interface, up to 16 EPAD2 modules = 128 ch
-
Input specifications
Voltage range
± 1400 V peak
Bandwidth of input amplifiers
DC to 300 kHz
Direct current input
5A
Max. input current via clamps
Max. input current via flexible coils
Depending on clamps
-
3000 A
-
A/D conversion
Sampling rate
250 kS/s aggregate
Resolution
10 kS/s
16 bit
Digital I/O and counters
Digital I/O, TTL level
Data storage
8 / 16 / 24
8 / 16 / 24
8 / 16 / 24
-
1)
Technology
Hard disk
SSD
Capacity
1000 GB
2 GB
Main system
1)
Intel® Core™ i7
Low power CPU
4x USB, 2x Ethernet, 1x RS-232
1x USB, 2x Ethernet,
1x RS-232
Standard
95 to 260 VAC 50 / 60Hz or 110 / 220 VDC
95 to 260 VAC 50 / 60 Hz
(internal 10 to 36 VDC)
Optional
48 / 110 V
-
Processor
Interfaces
Power supply
Dimensions
Housing
Dimensions (W x D x H)
Weight
1)
32
DEWE-818-PFR:
19” rack-mount, 4U
DEWE-30-16-PFR:
19” rack-mount, 3U
DEWE-818-PFR:
437 x 304 x 181 mm
(17.2 x 12 x 7.1 in.)
DEWE-30-16-PFR:
437 x 133 x 245 mm
(17.2 x 17.4 x 7.1 in.)
DEWE-818-PFR: 12 kg (26.4 lb.)
DEWE-30-16-PFR: 6 kg (13.2 lb.)
19” rack-mount, 4U
19” rack-mount, 4U
Counter panel mount
chassis
wall mount
DIN rail
437 x 443 x 181 mm
(17.2 x 17.4 x 7.1 in.)
437 x 443 x 181 mm
(17.2 x 17.4 x 7.1 in.)
160 x 166 x 125 mm
(6.2 x 6.5 x 4.9 in.)
Typ. 12 kg (26.4 lb.)
Typ. 12 kg (26.4 lb.)
Typ. 2 kg (4.4 lb.)
Please find current specifications in the latest price list
www.de we t ron .com
About us
Power Measurement
RPM and torque measurement, determination of efficiency factor
Harmonics analysis, record of dynamic processes
Examination of rotating field, hybrid cars and alternative drive systems
DEWE-2600-PM-1000
DEWE-5000-PM-1000
DEWE-2600-PM-1000-8: 8
DEWE-2600-PM-1000-16: 16
DEWE-5000-PM-1000-8: 8
DEWE-5000-PM-1000-16: 16
4 x HSI-HV and 4 x HSI-LV-D
Included DAQP modules at 16 channel units
8 x HSI-HV and 8 x HSI-LV-D
Bandwidth of input amplifiers
DC to 2 MHz
External quasi-static channel expansion
EPAD interface, up to 16 EPAD2 modules = 128 ch
A/D conversion
Sampling method
Sampling rate / channel
Simultaneous sampling
0.1 / 1 / 5 MS/s
Resolution
0.1 / 1 / 5 / 10 MS/s
0.1 / 1 / 5 MS/s
16 bit
Digital I/O, TTL level
CVT Logger
Digital I/O and counters
8
Counters or digital inputs, TTL level
(1 counter equals 4 digital inputs)
2/8
CAN bus option
UP-CAN-2
optional 2 high-speed CAN bus interfaces






Video input option
UP-DEWE-CAM-01
adds synchronized video picture acquisition, up to 70 fps at 640 x
480 pixel
Data storage
1)
Technology
Hard disk
Capacity
Max. gap free storing to disk
Typ. duration of recording (16 ch. / 10 kS/s/ch. / 16 bit)
Main system
1000 GB
1000 GB
1000 GB
Typ. 70 MB/s
Typ. 80 MB/s
Typ. 70 MB/s
35 days
20 days
35 days
-
15” TFT (1280 x 800)
1)
Display
Processor
17” TFT (1920 x 1080)
FULL HD
Intel® Core™ i7
Current transducer power supply 9 V
8 x lense for 9 V and ±15 V
Interfaces
4x USB, 2x Ethernet, 1x RS-232
Power supply
Standard
95 to 260 VAC 50 / 60Hz
110 / 220 VDC
Battery powered, 3 battery slots 2),
3 batt. for ~2 hrs. operation incl.,
incl. external AC power supply
95 to 260 VAC 50 / 60Hz
110 / 220 VDC
Optional
-
95 to 260 VAC 50 / 60Hz or 110 /
220 VDC
-
Dimensions
Housing
19” rack-mount, 4U
Portable instrument
Portable instrument
Dimensions (W x D x H)
437 x 443 x 181 mm
(17.2 x 17.4 x 7.1 in.)
417 x 246 x 303 mm
(16.4 x 9.6 x 11.9 in.)
460 x 351 x 192 mm
(18.1 x 13.8 x 7.7 in.)
Weight without batteries
Typ. 12 kg (26.4 lb.)
Typ. 14 kg (31 lb.)
Typ. 17 kg (37.4 lb.)
1)
Dedicated Instruments
Included DAQP modules at 8 channel units
Front-ends
DEWE-820-PM-1000
DEWE-820-PM-1000-8: 8
DEWE-820-PM-1000-16: 16
Software
Dynamic analog input channels
ORION Systems
TRION Systems
Wideband power analysis, engine test benches, transformer tests
Please find current specifications in the latest price list
33
Marlin Software for
Power Monitoring Applications
Fault Analysis, PQ and Energy Monitoring
Marlin is THE solution for electrical power engineering.
The recording of disturbances in power networks, the
calculation of all power quality parameters and the
measurement of performance and energy flows are the
main tasks that MARLIN performs. The software can be
run as a native Windows service in the background, and
unauthorized access to the instruments without user
credentials is not allowed. On small DEWE devices,
such as the DEWE-638 and DEWE-838 series, Marlin
runs as a Linux service.
Measurement and Evaluation at the same time
- Access from multiple workstations
The user interface is a pure web application and therefore allows the control and evaluation of each workstation in the network. Access via a browser independent
operating system is possible from all devices such as
tablet computers, smart phones, and any computer
workstation. Therefore, the data can be viewed by multiple users simultaneously, from any location.
Integration into your control system
If you prefer to have the data in your control system,
direct access of the data can be achieved using IP/ URL
technology. If you prefer to access the standardized IEC
60870-5-104 protocols, please use the “MARLIN APP
Scada 104” application.
Vector diagram at the Start Screen (see above)
Vector scope for 3-phase systems
Every harmonic can be shown
Display of multiple vector scopes on the same
screen via web browser technology
Measurement parameters
In addition to all aspects of 3-phase current and voltage,
parameters that can be measured include harmonics,
flicker, frequency and symmetrical components.
Triangle, star, and combined networks
Disturbance recorders can be used in all network
levels. Besides the classic star circuit with neutral, a
measurement in a triangle or a calculation of the lineto-line parameters is possible. A proper measurement
strictly according to the EN50160 standard in medium
and high voltage networks, in which the transducers are
connected in star, the assessment must be made line to
line. For two-phase systems and frequencies other than
50/60 Hz, there are also available settings.
Several power modules at once
Recording of the above parameters can be performed in
parallel by multiple virtual devices. It can simultaneously
measure current and voltages from summed feeders, as
well as a 3-phase configuration.
34
www.de we t ron .com
Statistics by DISDIP online
Adjustable number of harmonics
THD calculation
Limit manager (.e.g., IEC 61000-2-4, EN 50160…)
Alarm List
Device messages
Error messages
Performance & PQ Analysis
(IEC 61000-4-30 Class A)
Diagram: star, with triangular rating, triangle,
single and 3-phase
Trigger settings
U, I, f, P
Power band: star, delta, earth voltage
Regulation: star, delta, earth voltage
Phase 4 as earth voltage / star power
Frequency hopping
Frequency measurement, fundamental frequency
selectable
Power band: phase center
P, Q, S, PF, P1, Q1, cosine Phi (each 3 ~ and
phase values)
Active and reactive power changes
(single and 3-phase)
Harmonics, THD (IEC 61000-4-7)
Flicker (IEC 61000-4-15)
Power factor changes (single and 3-phase)
50160 on-line analysis
Symmetrical components
Star or delta
Signal voltage level
Change in current: phase center
About us
FFT for P - power direction determination
TRION Systems
List form
ORION Systems
Duration, altitude and time of the fault
FFT for U and I according to IEC 61000-4-7
Front-ends
Online Fault statistics
FFT - harmonic analysis
CVT Logger
Zoom in and zoom back during the
measurement!
Reporting of the nature and time of the fault
Dedicated Instruments
Recording of all parameters in adjustable
intervals
Online fault list
Software
Recorder
35
LabVIEW ™ library
LabVIEW™ is a graphical programming platform that
helps engineers scale from design to test and from
small to large systems. It offers unprecedented integration with existing legacy software, IP, and hardware
while capitalizing on the latest computing technologies.
LabVIEW™ provides tools to solve today’s problems and the capacity for future innovation - faster and more
effectively.
LabVIEW™ software is ideal for any measurement or
control system. Integrating all the tools that engineers
and scientists need to build a wide range of applications
in dramatically less time, LabVIEW™ is a development
environment for problem solving, accelerated productivity, and continual innovation.
We offer a comprehensive driver library for all DEWETRON
systems and components, accessible as palette in the
user library, as it is usual in LabVIEW™.
Instruments
Signal conditioning
Modules
DEWE-ORION multifunction A/D boards
Linux support
The DEWETRON TRION™ modules also can run under
a Linux environment (CentOS, Ubuntu and compatible distributions). Like all LabVIEW™ code, also the
DEWETRON LabVIEW™ libraries are platform independent and can be used on Linux as well.
Trion™ PXI measurement modules
36
Low level virtual instruments
Sample virtual instruments
Using low level vis you can create your own project from
scratch. Use them to access every single feature of the
multifunction ADC board, incl. but not limited to sample
rate, input ranges, AI channels, digital I/O, counter,
onboard RS-485 interface, CAN bus interface etc
For easier understanding or to expedite the development
process you might utilize one of the supplied examples.
www.de we t ron .com
About us
NItrogen
TRION Systems
Proprietary software or own programming?
When proprietary COTS software is not suitable for your
measurement application, there is no way around own
programming. But starting a software development project from zero is timeconsuming, expensive and error
prone.
Do not reinvent the wheel
ORION Systems
The DEWETRON Open Systems Software framework
NItrogen saves you from these problems. Written in
National Instruments LabVIEW™, one of the most popular development languages in the world of test and
measurement, NItrogen is dedicated to all faithful
LabVIEW™ programmers. The source code is included
in the premium package. This makes NItrogen a ready
to use software framework for your own development
project.
Program only what is specific for you
Front-ends
You can instantly use the software framework as it is,
delete whatever is dispensable, add or integrate your
own code and finalize your software project from an
“80% level” onwards. Get started instantly! All you
need to modify or extend the program is a valid license
LabVIEW™ FDS or PDS license.
Software
NItrogen consists of a core program and a range
of client vis. The core serves as setup tool for the
hardware and reads the data from the hardware.
The client vis are individual windows (within the
work space or undocked, even on a different
display) and will receive the scaled data for visualisation, processing, storage, analysis or other
purposes, even if they are not related to the data
flow. They can be started in multiple instances
which allows i.e. saving data to multiple files at
the same time, at different file formats and locations. Extend the collection of clients with your
own client vis for your personal needs.
Dedicated Instruments
CVT Logger
Get the source code
... remain independent!
37
DASYLab Drivers
for Signal Conditioning Modules and ORION-based Instruments
DEWETRON provides the complete measurement
chain in DASYLab. While the DAQP and PAD amplifier series are supported since DASYLab 5, the
AD-gap is now filled with the ORION-DAQ (16-bit
series) driver. The simultaneous sampled analog
inputs, synchronous digital inputs and counters,
sampling rates up to 5 MHz will give the complete
picture of the investigated device.
DEWETRON drivers and DASYLab run on Windows
32 and 64 bit.
AD input
The DASYLab driver supports the whole ORIONDAQ (16-bit) series. Also multiple AD cards can
be combined to extend channels. The smart driver
architecture does automatic hardware synchronisation of multiple cards.
ORION-1616-100
ORION-3216-100
ORION-1616-500
ORION-0816-1000
ORION-1616-1000
ORION-0816-5M
DAQP series modules
PAD modules
Digital and counter inputs
The ORION-DAQ (16-bit series) card also supports
synchronous digital and counter inputs. Digital and
counter inputs are read with the selected sampling
rate. Compared to other AD cards where this is
read asynchronous, this feature enables that fast
digital channels can be measured with the full
sampling rate. The outstanding digital input filter
of the ORION counters will support measurements
at harsh electrical environments.
Basic event counting
Gated event counting
Up down counting
Basic encoder
38
www.de we t ron .com
About us
Operating systems
WIN XP, 32-bit
CVT Logger
DAQP scaling and programming module, and the PAD module are completing the whole input measurement chain.
The DEWETRON scaling module is used
to program the DAQP modules (range,
filters, ...) and rescale to amplifiers
input range. PAD input blocks are used
to read data directly from the PAD
amplifiers.
Dedicated Instruments
DAQP and PAD modules
Front-ends
ORION Systems
The ORION cards also support external
clock and trigger, which is usefully to
synchronize to other clock sources, or
to rotary encoders to change into order
domain world. Two free programmable
clockout channels, can be used to
sync other devices.
TRION Systems
Clock, trigger and clockout
WIN 7, 64-bit
Software
WIN 7, 32-bit
39
DS-7
for turn-key R&D Applications
DEWETRON customers in the R&D world don’t want
to write software, or run on LINUX - they just want a
turn-key software application that can be used within minutes. DEWESoft™ (DS-7 for short) is a great
package that perfectly supports most DEWETRON
hardware.
Runs under Windows
DS-7 was written specifically for Windows, and does
not run on any other operating system. But that’s
perfectly fine for test and measurement specialists
in the research sector. Data acquisition systems
used in this sector are typically used for something
different all the time, and flexibility is more important
than long-term stability.
The feature set provided by DS-7 is truly impressive.
You can acquire high speed (dynamic) data from
DEWETRON ORION and TRION series hardware
(plus all of our signal conditioners), as well as hundreds of channels of asynchronous data from CAN,
ARINC, 1553, SERIAL, and more.
Easy visualization
One of the most popular aspects of DS-7 is how
easy it makes it for you to arrange the screens just
the way that you like them. It provides recorder
graphs, scopes, analog and digital meters, 2D and
3D graphs, tabular displays, text objects, X-Y graphs,
and more. Place them in any arrangement and
assign the channels into them that you want. DS-7
makes that very fast and easy. The entire setup is
saved, so you can create countless configurations
and recall them in a matter of seconds.
MATH functions
DS-7 includes a rich set of pre-made MATH functions that you can apply to your data DURING
recording, or AFTER recording. These include programmable filters, integration, FFT analysis, and
so much more. When the computer is not powerful
enough to handle what you want to do in real-time,
you can set any or all of the MATH functions to be
processed after recording. DS-7 is not as powerful
as a real analysis tool such as Flexpro or Matlab, but
it’s pretty darn good for the money.
40
Exporting and Printing
A wide variety of export filters are included, for all of the
most popular analysis tools - even Excel! And you can print
your data in full color to any attached Windows printer,
or to a PDF document that can be printed from another
computer.
www.de we t ron .com
64-Bit Integers and pointers to 64-bit Integers
Pointers to zero-terminated ASCII-Strings
(no Unicode/Wide string Support)
All public interface functions are accessible by using the
Standard C. Therefore, any programming language that allows
the above mentioned perqui sites can exploit the functionality
of the API.
DEWE2 Explorer included
If you’re using the TRION hardware, the API will install a DEWE2
Explorer application (delivered standard with all DEWE2 systems). Besides providing in-depth system infor- mation, this
tool enables users to run self-tests of TRION modules, enable
logging files in case of errors and to easily upgrade the firmware of TRION modules.
The explorer can also create a virtual system in addition to the
real one, to aid you in programming your own application even
without the real hardware.
About us
TRION Systems
ORION Systems
32-Bit Integers and pointers to 32-bit Integers
Front-ends
The DEWETRON TRION SDK is shipped with the necessary
interface files for C/C++ (.h -Files) and Pascal-dialects like
Delphi (.pas – Files) Using these files, direct integration into
the application can be achieved by including them. But this
is not the limit, because many languages are supported indirectly. All public Interface functions use the “std-call” calling
convention. And all public interface functions accept the following primitive data-types:
CVT Logger
If your prefer to write your own program code in C, C++, C#,
Visual Basic, Python or Java, our SDK for TRION is available
for you.
Dedicated Instruments
Software Development Kit
Software
DEWETRON OEM
41
Accessories
Carrying cases and transportation systems
are available for all systems.
FireWire and Ethernet cameras;
Split-box for supplying and connecting Ethernet cameras
Car seat mounting kits for our mobile systems
GPS based speed and displacement sensor
Power supplies, battery and distribution boxes
Several solutions for current measurement from simple shunts
to current clamps and high-precision zero flux transducers.
Encoders for combustion analysis and
torsional and rotational vibration applications
42
www.de we t ron .com
Combustion Analysis
Road Load Data
Basic Brake Test
Vehicle Dynamics
Adaptive Cruise Control
Torsional & Rotational Vibration
E-Mobility
Race Car
Energy & Power Analysis
Systems & Components
E-Mobility
Power Measurement
Power Network Analysis
Power Fault Recording
Flight Test
Engine Test
Aerospace & Defense
TRION Systems
Automotive
ORION Systems
Functional Safety
About us
Measuring Batteries
Wind Tunnel Test
Maintenance
Safety Equipment
Cabin Comfort
Front-ends
Applications
Hybrid Testing
System Integration Lab
Noise and Vibration
Tactical/Land Vehicle
Transportation
Structural Test
CVT Logger
Component Test
Modal Test
Noise Origin
Current Collector Test on Trains
Power supply of railway systems
Mixed Signal Recorder
Dynamic Signal Analyzer
Balancing
Strobe Cam
Order Tracking
Modal Analysis
Torsional & Rotational Vibration
Software
General Test & Measurement
Dedicated Instruments
PCM Telemetry
Transient Recorder
Distributed Systems
43
MAINTENANCE
CALIBRATION
HELP DESK
TRAINING
UPGRADE
DE-B131101E • All trademarks are acknowledged to be the property of their owners. Specification subject to change without notice. © DEWETRON GmbH 04/2015
CUSTOMER CARE CENTER
DEWETRON GmbH • Parkring 4 • A-8074 Grambach • Tel +43 (0)316 3070 0 • Fax +43 (0)316 3070 90 • info@dewetron.com