Why DEWETRON? - Milano Systems
Transcription
Why DEWETRON? - Milano Systems
SHORT FORM CATALOG From our founding in 1989, DEWETRON has become a market-leading provider of test and measurement systems. Our 200+ employees are located at our headquarters in Graz, Austria and also in more than 25 countries around the world. DEWETRON is a member of the TKH group. We provide highest quality Test & Measurement Solutions for Automotive Power & Energy Aerospace Transportation General T & M Reference Customers NASA, Airbus, OMV, Lockheed Martin, Lufthansa, Honda, Harley Davidson, Johnson & Johnson, Renault, Rolls Royce, Windtest, Verbund Hydro, Rockwell Collins, Schindler, Trumpf, Technical University Vienna, Pirelli, Kawasaki, Bell Helicopter, Boeing Commercial Airplanes, Bombardier, New York Subway, Trenitalia, Continental, and many more ... 2 www.de we t ron .com We have the expertise & we go the extra mile for our customers About us Since 25 years data acquisition is all we do. As we are producing instruments each new development is based on huge experience in making data acquisition systems. Customization is one of our biggest strengths - we love the challenge and we like to go the extra step for our customers to enable highest quality test and measurement data in shortest time. TRION Systems There is a whole team of application engineers with 10+ years of experience to support challenging applications. Quality ORION Systems Our commitment to Total Quality Management is based on the understanding of what is important for the success of our customers. It starts with the definition of the technical specification, covers the development, production, quality control, shipment, and ends with support and service of our systems during operation. DEWETRON is ISO 9001:2008 and ISO 14001:2009 certified. Environmental and quality management is more than just a compliance issue for us; it is an integral part of our business operations. Shaketest procedure ISO certificate DEWE-ACADEMY In the DEWE-ACADEMY single or multi-day events are offered. Professionals teach the practical application of our measurement systems, based on the relevant theory. ACADEMY Calibration Software DEWETRON maintains two top-notch calibration facilities with the same equipment: one at our worldwide headquarters in Austria, and another one at DEWETRON USA in Rhode Island. Our cal lab is based on the Fluke 5500 series calibrator, and we run the METCAL calibration system, which allows us to automate nearly every process. Dedicated Instruments Extensive temperature tests (-40 to +70 °C) CVT Logger Front-ends We take quality very seriously! That is why we have our own environmental test facilities in our building in Austria, where all DEWETRON products are tested.. www.dewetron.com/dewe-2600 3 Content About us Why DEWETRON 5 Instrument families 6 System overview 7 Unlimited measurements with more... 8 TRION Systems TRION series modules 10 All-in-One TRION systems 11 Mainframes TRION 12 Front-ends TRION 14 Distributed systems over large distance 15 ORION Systems ORION A/D boards 16 High-speed amplifiers 17 Dynamic amplifiers 18 Differential amplifiers 20 MSI Series 21 All-in-One ORION systems 22 Mainframes ORION 24 Front-ends PCI front-ends ORION 26 USB & Ethernet front-ends ORION 27 EPAD/CPAD signal conditioning 28 CVT Logger CVT Logger 30 Dedicated Instruments Power Network Analyzers 31 Power Fault Recorders 32 Power Measurement 33 Software Marlin 34 LabVIEW™library 36 NItrogen 37 DASYLab Drivers 38 DS-740 DEWETRON OEM 41 Accessories Accessories42 4 www.de we t ron .com ADC-clock Counter/encoder inputs of TRION™ modules are phase synchronized. Refering to the diagram, you can see that a standard counter is always a sample behind. With software interpolation you can get closer, but only DEWETRONs advanced technology is both, fully phase AND amplitude corrected. Counter input Ideal counting SuperCounter™ Software interpolation Standard counter Scalable and Modular The ability to scale from a few channels to many and to split in several housings without compromising the simultaneous data sampling of all channels is unique. User Exchangeable Modules All TRION™ amplifier modules can be changed within a few seconds. Modules in different sampling speed and resolution can be used in one chassis. Use isolated and differential inputs at the same time. Global Support Our engineers are in 25 countries around the world to support you with their knowledge and expertise. We offer maintenance, upgrades, ISO certified system calibrations and also customer trainings! ORION Systems SuperCounter™ Front-ends TRION™ series modules easily take it on with all similar products on the market. CVT Logger Highest Precision Dedicated Instruments The quality of synchronized measurement data has top priority at DEWETRON which is guaranteed by the SYNC-CLOCK™ technology. Analog, digital, GPS, counter, CANbus, ARINC and video as well as major sensor systems like Kistler RoaDyn ® 2000 wheel or GeneSys ADMA INS/GPS system etc. are already recorded synchronously during the measurement. Software SYNC-CLOCK™ Technology TRION Systems About us Why DEWETRON? 5 Instrument Families There are two product families of DEWETRON data acquisition systems, the DEWE2 (TRION™) and the DEWE (ORION) series. All instruments of both series can record vastly different signal sources in perfect sync. The analog input modules are leading technology and guarantee precise and robust results while offering the right input for almost any sensor. Sensor Flexible connector panel Signal conditioning Filtering A/D conversion High speed data transfer and synchronization DEWE2 Series with TRION™ Modules DATA ACQUISITION MODULES HOUSING AND STORAGE Counter CAN bus Analog signal conditioning & A/D conversion USER EXCHANGEABLE TRION™ MODULES WIDE RANGE OF HOUSINGS Highest precision Most rugged Highest channel density Fully modular: user exchangeable modules for analog, digital, counter, CAN DEWE Series with ORION Cards and DAQ Modules SIGNAL CONDITIONING MODULES HOUSING AND STORAGE AND I/O CARDS Analog signal conditioning A/D conversion DEWE-ORION A/D CARDS Counter CAN bus ANALOG DAQ MODULES Isolated or differential analog inputs A/D resolution 16, 22 or 24 bit 6 WIDE RANGE OF HOUSINGS Separated A/D card for flexible sampling rates up to 10 MS/s www.de we t ron .com About us System Overview IN ADC TRION Systems All-in-one OUT Built-in display, keyboard and touchpad Most compact and flexible configuration Powerful PC inside for fast online displays and analsis ORION Systems Most convenient for mobile applications Mainframes ADC OUT Front-ends IN Keyboard and pointing device are included loose Powerful PC inside for fast online displays and analysis Can be used with external display CVT Logger Very popular for applications where the instrument is installed in a poorly visible place for the user Front-ends ADC OUT Dedicated Instruments IN Robust high-speed PCI Express bus To be used with an external computer Expansion for A or M instruments Multiple units can be daisy-chained Signal Conditioning Software Stand-alone signal conditioning Front-ends for existing recorders, A/D cards … Channel expansion for DEWETRON instruments Signal Conditioning Amplifier AD Conversion Computer inside Display 7 Unlimited Measurements with... ... more CHANNELS High-speed expansion Add one or more Front-end chassis for high-speed expansion DEWE2-F7s DEWE2-F4s Network setup on page 15 TRION-SYNC-bus PCIe connection up to 7 meters Low-speed expansion 100 Hz CPAD3 modules with CAN interface Quasi-static expansion 12 Hz Add one or more EPAD2 modules at any time ... more SOFTWARE 8 www.de we t ron .com About us ... more CONNECTIVITY Analog inputs TRION Systems Digital inputs Counter Video ARINC-429, MIL-STD-1553 GPS, VGPS, absolute timing ORION Systems Inertial data CAN PCM telemetry FlexRay Front-ends XCP CVT Logger -12,5 -100 ... more INSIGHT Infrared cam Software High-speed cam Dedicated Instruments 250 162,5 162,5 Rec 10 MS/s sampling rate 1 MS/s sampling rate U1_1MS; - [V] 75 U1_10MS; - [V] 75 -12,5 -100 50 MB/s SYSTEM B 100 MB/s SYSTEM A 150 MB/s SYSTEM C 200 MB/s DEWE-2600-STREAM 305 MB/s 250 ... MORE POWER GigE cam USB cam 9 Modules Simultaneous sampling for DEWE2 series Separate ADC on each channel User exchangeable modules ANALOG Modules Channels V TRION-2402-MULTI TRION-1620-ACC TRION-1620-LV TRION-2402-V TRION-1603-LV 204.8 kS/s 24 bit yes DSUB, LEMO 0B V 6 2 MS/s 1 MS/s 16 bit 24 bit yes BNC V 6 2 MS/s 1 MS/s 16 bit 24 bit yes BNC, LEMO 1B V 4 or 8 204.8 kS/s 24 bit yes Safety banana sockets V 6 250 kS/s 16 bit yes BNC, LEMO 1B 6 to 8 204.8 kS/s 24 bit no RJ-45, DSUB, LEMO 1B, LEMO 0B 204.8 kS/s 24 bit no SMB, BNC 100 100 1000 100 TRION-2402-dACC V V 10 V 6 to 8 100 Voltage (1000 V) Current (shunt needed) Bridge DIGITAL Modules IEPE Channels RTD Potentiometer Sample rate Resolution Isolation per channel SuperCounter™ inputs Connector Type TRION-CNT 6 to 18 800 kS/s 80 MHz yes DI, CNT TRION-DI-48 48 2 MS/s 80 MHz yes DI TRION-BASE 1 to 8 2 MS/s 80 MHz - DI, DIO, CNT, SYNC, AUX 1 to 8 2 MS/s 80 MHz - GPS antenna, IRIG In / Out, DIO, CNT, SYNC, AUX TRION-TIMING DEDICATED Modules GPS 00101001010001 TRION-CAN Channels Sample rate Resolution Isolation per channel Connector Type 2 or 4 n/a n/a yes DSUB 1 n/a n/a - DSUB 1 CNT 8 DIO 2 MS/s 0.01 km/h < 10 cm - GPS antenna, IRIG In / Out, DIO, CNT, SYNC, AUX TRION-A429 4, 8, 16 or 30 - n/a - SCSI-3 TRION-M1553 1,2 or 4 - n/a - SCSI-3 TRION-MA4 9, 10, 12 or 13 - n/a - SCSI-3 Update rate max. 2.8 MS/s 2 16 bit - BNC TRION-FLEXRAY TRION-VGPS TRION-1628-AO-2 10 Connector Type 4 or 8 100 TRION-2402-dSTG 1000 Sample rate Resolution Isolation per channel GPS www.de we t ron .com About us All-in-One TRION Systems Built-in display, keyboard and touchpad Most compact and flexible configuration Powerful PC inside for fast online displays and analysis Slots for TRION™ acquisition modules DEWE2-A4 DEWE2-A7 DEWE2-A13 4 7 13 High-speed channel expansion Add Front-end chassis or setup network Low-speed channel expansion 100 Hz CPAD3 via TRION-CAN EPAD2 120 GB removable Solid State Disk 1 TB hard disk Up to 480 GB SSD Up to 480 GB SSD Optional data storage Display 13“ (1280 x 800) 17“ (1920 x 1080) FULL HD Power supply 10 to 36 VDC isolated incl. external AC power supply 90 to 264 VAC Option 1 Internal buffer battery for ~ 5 min. operation max. 10 to 36 VDC Internal buffer battery for ~ 2 min. operation Option 2 DW2-UPS-150-DC (ext. battery pack), 2 battery slots Battery powered, 4 battery slots for ~2 hours operation 318 x 253 x 128 mm (12.5 x 10 x 5 in.) 450 x 246 x 303 mm (17.7 x 9.7 x 11.9 in.) Typ. 5.9 kg (13 lb.) Typ. 15 kg (33 lb.) Input voltage (max.) Dimensions Dimensions (W x D x H) (without handle) Weight without modules and batteries 1) Software Weight of one battery: 660 g (1.45 lb.) CVT Logger Data storage Dedicated Instruments Quasi-static channel expansion Front-ends ORION Systems Most convenient for mobile applications DEWE-CAM-01 Add video data to your measurements via high shock and vibration resistant camera DW2-UPS-150-DC, 130 W UPS with 2 slots for batteries DW2-A13-CC Shipping/carrying case 11 Mainframes Most compact and flexible configuration Powerful PC inside for fast online displays and analysis Most convinient for mobile applications Slots for TRION™ acquisition modules High-speed channel expansion DEWE2-M4 DEWE2-M4s 4 4 7 n/a Add Front-end chassis or setup network Add Front-end chassis or setup network Low-speed channel expansion 100 Hz CPAD3 via TRION-CAN Quasi-static channel expansion Data storage DEWE2-M7s EPAD2 EPAD2 or CPAD2 via TRION-CAN 120 GB removable Solid State Disk Optional data storage 120 GB Solid State Disk up to 480 GB Power supply 10 to 36 VDC isolated; incl. external AC power supply Standard (max.) Add internal buffer battery for ~ 5 min. operation Option 1 DW2-UPS-150-DC (ext. battery pack), 2 battery slots n/a DEWE-UPS-300-DC Dimensions (W x D x H) (without handle) 318 x 253 x 108 mm (12.5 x 10 x 4.3 in.) 177 x 230 x 177 mm (4 u) (7 x .9.1 x 7 in.) without feet 258 x 230 x 177 mm (4 u) (10.2 x 9.1 x 7 in.) without feet Weight without modules and batteries1) Typ. 3.9 kg (8.6 lb.) Typ. 3.9 kg (8.6 lb.) Typ. 4.9 kg (10.8 lb.) Option 2 Dimensions 1) Weight of one battery: 660 g (1.45 lb.) CAM-SPLIT-BOX 12 BAT-CHARGER-1 BAT-CHARGER-4 DE-POWERBOX-12 DC Power distribution box www.de we t ron .com About us TRION Systems ORION Systems DEWE2-M13 DEWE2-M18 13 13 18 Add Front-end chassis or setup network Ethernet CPAD3 via TRION-CAN 1 TB Hard Disk (plus two 3,5“ bays) 120 GB Solid State Disk up to 480 GB up to 3 TB up to 480 GB 10 to 36 VDC isolated; incl. external AC power supply 90 to 264 VAC 90 to 264 VAC Add internal buffer battery for ~ 2 min. operation Redundant AC power supply n/a Battery powered, 4 battery slots for ~2 hours operation n/a n/a 441 x 427 x 177 mm (4 u plus 1 u for cooling in cabinet required) (17.4 x 16.8 x 7 in.) without feet Typ. 7.3 kg (16 lb.) Typ. 13 kg (28.6 lb.) Software 441 x 230 x 177 mm (4 u plus 1 u for cooling in cabinet required) (17.4 x 9.1 x 7 in.) without feet CVT Logger CPAD2 via TRION-CAN 120 GB Solid State Disk Dedicated Instruments EPAD2 or CPAD2 via TRION-CAN Front-ends DEWE2-M13s MOB-DISP-12 External display DEWE2-M13s with 4 battery slots DEWE2-M13 with 2x option DW2-M13-BAY35-SATA 13 Front-ends Most compact and flexible configuration High-end A/D conversion Data transmission via PCIe (up to 7 m) or fibre-optic Slots for TRION™ acquisition modules DEWE2-F4s DEWE2-F7s DEWE2-F13s 4 7 13 High-speed channel expansion DEWE2-F13-FIBRE DEWE2-F18 13 18 Firbre-optic (needs fibre-optic card in host) PCIe Daisy-chain another Front-end chassis Low-speed channel expansion 100 Hz CPAD3 via TRION-CAN Quasi-static channel expansion CPAD2 via TRION-CAN (no EPAD) Interface to host PCIe Power Supply Power supply standard (max.) 90 to 264 VAC Option 1 max. 10 to 36 VDC isolated max. 10 to 36 VDC isolated Redundant AC power supply Redundant AC power supply Redundant AC power supply Option 2 Add internal buffer battery for ~ 5 min. operation (requires DC option) Add internal buffer battery for ~ 5 min. operation (requires DC option) max. 10 to 36 VDC isolated; Additional buffer battery for ~ 2 min. operation n/a n/a Option 3 n/a n/a Battery powered, 4 battery slots1) for ~2 hours operation n/a n/a Dimensions (W x D x H) (without feet) 177 x 230 x 177mm (4 u) (7 x 9.1 x 7 in.) 258 x 230 x 177 mm (4 u) (10.2 x 9.1 x 7 in.) 441 x 230 x 177 mm (4 u) (17.4 x 9.1 x 7 in.) 441 x 427 x 177 mm (4 u) (17.4 x 16.8 x 7 in.) 441 x 427 x 177 mm (4 u) (17.4 x 16.8 x 7 in.) Weight without modules and batteries1) Typ. 3.9 kg (8.6 lb.) Typ. 4.9 kg (10.8 lb.) Typ. 8 kg (17.6 lb.) Typ. 12 kg (26.4 lb.) Typ. 12 kg (26.4 lb.) Dimensions 1) Weight of one battery: 660 g (1.45 lb.) LINK-HOST-EX34 ExpressCard-34 host card 14 DEWE-DCDC-24-300-ISO DEWE2-F13s with option DW2-PS-AC-RED www.de we t ron .com Network with multiple systems WLAN DEWE2-A4 with TRION-BASE module DEWE2-M7s with TRION-BASE module Sync up to 1000 meters (IRIG DC, cable length delay compensation) GPS-SYNC GPS Two or more instruments synchronized via GPS TRION Systems ORION Systems DEWE2-F13-FIBRE with TRION-TIMING module Front-ends IRIG-SYNC CVT Logger DEWE2-M13 with TRION-TIMING module Dedicated Instruments 50 m Fibre link for data transfer Software Example: DEWE2-M13 expanded with DEWE2-F13-FIBRE via fibre-cable for long distance About us Distributed systems over large distance 15 ORION A/D Boards Simultaneous sampling with separate A/D converter per channel Clock output for synchronizing external devices, e.g. cameras Synchronized analog, digital, counter and CAN inputs Model overview Analog input channels Input ranges Resolu tion Max. sampling rate / channel Type of ADC Digital input channels Digital I/O Counter / Encoder CAN DEWE-ORION-0824-20x series 8 Voltage: ±0.1 V, ±0.5 V, ±2 V, ±10 V IEPE®: 4 mA / 8 mA excitation 24 bit 204.8 kS/s delta-sigma with antialising filter up to 40 8 up to 10 (advanced) up to 2 DEWE-ORION-0816-100x series 8 Voltage: ±1.25 V, ±2.5 V, ±5 V, ±10 V 16 bit 1 MS/s successive approximation (SAR) up to 40 8 up to 10 up to 2 DEWE-ORION-0816-5Mx series 8 Voltage: ±5 V 16 bit 5 MS/s successive approximation (SAR) up to 8 8 2 (advanced) up to 2 DEWE-ORION-0816-10Mx series 8 Voltage: ±5 V 16 bit 10 MS/s successive approximation (SAR) up to 8 8 2 (advanced) up to 2 DEWE-ORION-1624-20x series 16 Voltage: ±10 V 24 bit 204.8 kS/s delta-sigma with antialising filter up to 40 8 up to 10 (advanced) up to 2 DEWE-ORION-1622-10x series 16 Voltage: ±10 V 22 bit 102.4 kS/s delta-sigma with antialising filter up to 40 8 up to 10 (advanced) up to 2 DEWE-ORION-1616-10x series 16 Voltage: ±1.25 V, ±2.5 V, ±5 V, ±10 V 16 bit 100 kS/s successive approximation (SAR) up to 40 8 up to 10 up to 2 DEWE-ORION-1616-100x series 16 Voltage: ±1.25 V, ±2.5 V, ±5 V, ±10 V 16 bit 1 MS/s successive approximation (SAR) up to 40 8 up to 10 up to 2 DEWE-ORION-3222-10x series 32 Voltage: ±10 V 22 bit 102.4 kS/s delta-sigma with antialising filter up to 24 8 2 (advanced) up to 2 DEWE-ORION-3216-10x series 32 Voltage: ±1.25 V, ±2.5 V, ±5 V, ±10 V 16 bit 100 kS/s successive approximation (SAR) up to 24 8 2 up to 2 Options and Accessories DEWE-ORION-xxxx with additional digital inputs 16 DEWE-CAN-CAB2 option Connects the built in Lemo conn. with your D-Subs ORION-CAN-PANEL 9-pin D-Sub connectors for CAN channel 0 and 1 ORION-xxxx-SYNC option Synchronization with PC based instruments Built-in digital I/O and counter/encoder connectors (option) www.de we t ron .com About us High-speed Amplifiers Selectable filters and multiple ranges Analog signal output (±5 V) Module Bandwidth (BW), Isolation (ISO), TEDS Filters (LP = lowpass, Overvoltage HP = highpass) protection (OP) Input type Ranges Strain gauge, bridge sensors ±0.1 to ±1000 mV/V (@ 5 VDCexc) BW: up to 2 MHz ISO: 350 VDC Piezoresistive bridge ±0.5 to 10000 mV/mA (@ 1 mAexc) LP: 100 Hz to 2 MHz OP: ±50 VDC Voltage ±500 µV to ±10 V HP: 1 Hz Resistance 25 mΩ to 100 kΩ Pt100, Pt200, Pt500, Pt1000, -200° C to 850° C Universal measurement HSI-STG V MSI Charge via MSI-BR-CH-50 up to 50000 pC Voltage via MSI-BR-V-200 up to ±200 V High voltage ±20 to ±1400 V High voltage measurement HSI-HV - BW: 2 MHz ISO: 1.8 kVRMS LP: 100 Hz to 2 MHz V Voltage & current measurement HSI-LV V MSI MSI Voltage ±10 mV to ±50 V Current with external shunt 20 mA / 5 A IEPE® via MSI-V-ACC ±10 mV to 5 V Pt100, Pt200, Pt500, Pt1000, -200° C to 1000° C and Pt2000 and resistance via 8 to 4 kΩ MSI-V-RTD BW: 2 MHz LP: 100 Hz to 2 MHz ISO: up to 1 kVRMS OP: 350 VDC Dedicated Instruments MSI Software ±100 to ±10000 mV Thermocouple via MSI-BR-TH-x full range of TC type CVT Logger Pt2000 IEPE® via MSI-BR-ACC MSI ORION Systems Front-ends High bandwidth up to 2 MHz TRION Systems Isolated single channel module 17 SelectionAmplifiers Guide Dynamic DAQ Series Modules Isolated dynamic single channel module Single High isolation channelup to 1.8 kV RMS High bandwidth -up 300 kHzsignals fortodynamic (mostvia models) Isolation Configuration RS-485 interface Analog signal output (±5 V) Pure signal conditioning solution in conjunction with DEWE-30 series racks Module Input type Ranges Bandwidth (BW), Isolation (ISO), TEDS Filters (LP = lowpass, Overvoltage HP = highpass) protection (OP) Universal measurement DAQP-STG V Strain gauge, bridge sensors ±0.1 to ±1000 mV/V (@ 5 VDCexc) Piezoresistive bridge ±0.5 to 10000 mV/mA (@ 1 mAexc) Voltage ±500 µV to ±10 V Resistance 25 mΩ to 100 kΩ Pt100, Pt200, Pt500, Pt1000, -200° C to 850° C BW: 300 kHz ISO: 350 VDC LP: 10 Hz to 300 kHz OP: ±50 VDC Pt2000 IEPE® via MSI-BR-ACC ±100 to ±10000 mV Thermocouple via MSI-BR-TH-x full range of TC type MSI MSI MSI DAQP-MULTI V Charge via MSI-BR-CH-50 up to 50000 pC Voltage via MSI-BR-V-200 up to ±200 V Thermoresistors Pt100, Pt200, Pt500, Pt1000 and Pt2000, free programmable range Thermocouple Type K, J, T, R, S, N, E, B, L, C, U free programmable range Resistance 1 Ohm to 1 MOhm Piezoresistive bridge Voltage Current (with external shunt) 13 ranges (±0.5 to 5000 mV/mA) 10 ranges from ±5 mV to ±5 V depending on external shunt High voltage ±20 to ±1400 V ISO: 1 kVRMS BW: 3 kHz LP: 3, 10, 30, 100, 300, 1000 Hz High voltage measurement DAQP-HV - V BW: 300 kHz ISO: 1.8 kVRMS LP: 10 Hz to 300 kHz Voltage & current measurement DAQP-LV V MSI DAQN-AIN V 18 MSI MSI Voltage ±10 mV to ±50 V Current with external shunt 20 mA / 5 A IEPE® via MSI-V-ACC ±10 mV to 10 V Pt100, Pt200, Pt500, Pt1000, -200° C to 1000° C and Pt2000 and resistance via 0 to 6.5 kOhm LP: 10 Hz to 300 kHz ISO: up to 1 kVRMS OP: 350 VDC - OP: < ±500 V BW: 300 kHz MSI-V-RTD Charge via MSI-V-CH-50 up to 50000 pC Voltage ±10 V (1:1 input) - (jumper selectable) www.de we t ron .com DAQP-LA-B Current 0.1 A to 30 A peak Note: 5 ARMS continuous max. 5 ARMS contin. current - Current 2 mA to 600 mA BW: 300 kHz ISO: 1.4 kVRMS LP: 10 Hz to 300 kHz - Note: typ. 20 mA application BW: 300 kHz ISO: 1.4 kVRMS LP: 10 Hz to 300 kHz Carrier frequency amplifier DAQP-CFB2 AC bridge, strain gauge Bridge: 0.1 to 1000 mV/V - Note: programable sine wave excitation up to 20 kHz BW: DC to 9.6 kHz OP: ±10 VDC LP: 10 Hz to 1 kHz Inductive sensors, LVDTcapacity Inductive: 5 to 1000 mV/V Capacity 20 pF to 1 µF IEPE® sensors ±50 mV to ±5 V Charge / IEPE® measurement DAQP-ACC-A - BW: 0.5 Hz to 300 kHz LP: 1 to 300 kHz HP: 0.5 Hz and 5 Hz DAQP-CHARGE-A Charge sensors Charge: 5 to 50000 pC IEPE® sensors IEPE®: ±5 mV to 5 V - Charge sensors - LP: 100 Hz to 50 kHz HP: 0.1 Hz to 10 Hz Note: selectable integration and double integration DAQP-CHARGE-B BW: 0.1 Hz to 50 kHz ±100 to ±1 000 000 pC - BW: DC to 100 kHz ISO: 350 VDC LP: 10 Hz to 100 kHz HP: DC, 0.001 Hz to 0.5 Hz Note: selectable time constant for static sensors Temperature measurement DAQP-THERM Thermocouple Type K, J, T, R, S, N, E, B, L, C and U selectable Note: internal CJC and linearisation free programmable range Frequency 100 Hz to 200 kHz - BW: 3 kHz ISO: 1 kVRMS LP: 3, 10, 30, 100, 300, 1000 Hz Frequency measurement DAQP-FREQ-A - About us DAQP-LA-SC TRION Systems Current measurement ORION Systems Bandwidth (BW), Isolation (ISO), TEDS Filters (LP = lowpass, Overvoltage HP = highpass) protection (OP) Ranges BW: according to range ISO: 350 VDC Output response: 1.5 ms 30 ms 500 ms Front-ends Input type CVT Logger Module Voltage output 1:1 output module with isolation - BW: 400 Hz ISO: 240 VDC Input voltage: ±10 V Output voltage: ±10 V OUT ADAP-D9M-BNCF: DSUB to BNC adapter for DAQP-V series and DAQP-FREQ modules BNC to Microdot adapter CONN-DSUB-9: (included as a standard with Screw terminal adapter DAQP-CHARGE-A modules) for all modules with 9-pin DSUB connector BNC to banana and banana to BNC adaptors Isolated high-voltage amplifier: DAQP-HV Software DAQN-V-OUT Dedicated Instruments Voltage output module 19 Differential Amplifiers Multi-channel differential amplifiers Small form factor for high channel density Cost effective Support of MSI (Modular Smart Interface) SUB Modules for MDAQ-BASE-x # Input type CH Module MDAQ-SUB-STG-D 8 Connector: DB-9 Ranges Strain-gage (Full-, half and quarterbridge, incl. shunt calibration) for strain gage application MSI V MSI MSI MDAQ-SUB-V-200-D 8 Connector: DB-9 V MSI 14 ranges from ±0.5 to 1000 mV/V (@ 5 VDC excitation Voltage up to ±10 V 15 ranges from ±2.5 mV to ±10 V ICP via MSI-BR-ACC 7 ranges from ±0.25 mV to ±10 V Voltage up to 200 V via MSI-BR-V-200 6 ranges from ±10 to ±200 V Thermocouple via MSI-BR-TH-x full range of TC type Pt100, Pt200, Pt500, Pt1000, Pt2000 -200 °C to 1000 °C and resistance via MSI-BR-RTD and 0 to 6.5 kOhm Voltage up to ±200 V 13 ranges from ±0.125 to ±200 V ICP, via MSI-V-ACC 7 ranges from ±0.25 mV to ±10 V Pt100, Pt200, Pt500, Pt1000, Pt2000 -200 °C to 1000 °C and resistance via MSI-V-RTD and 0 to 6.5 kOhm Bandwidth (BW), Excitation Highpass filters (HP) BW: 30 kHz BW: 300 kHz 0 to 12 VDC ±15 VDC and 0 to 12 VDC Note: for safety reasons, max. 120 VDC or 50 VAC are allowed at this connector MSI MDAQ-SUB-V-200-BNC TEDS 8 Voltage up to ±200 V 13 ranges from ±0.125 to ±200 V - BW: 300 kHz - BW: 300 kHz 4 / 8 mA Connector: BNC V MDAQ-SUB-ACC-BNC Note: for safety reasons, max. 120 VDC or 50 VAC are allowed at this connector 8 ICP® or voltage up to ±10 V 8 ranges from ±125 mV to ±10 V Connector: BNC HP: 3.4 Hz Single-ended or differential input and one highpass filter 3.4 Hz highpass filter for noise and shock response measurement MDAQ-SUB-ACC-A-BNC Connector: BNC 8 MDAQ-SUB-ACC-BNC-S1 0,16 Hz for structural and modal analysis, human body vibration measurement (rest same as MDAQ-SUB-ACC-BNC) ICP® or voltage up to ±10 V MDAQ modules - available in most of the DEWETRON multichannel systems. 20 8 ranges from ±125 mV to ±10 V Single-ended input and two HP filters 0.16 Hz for structural and modal analysis, human body vibration measurement 3.4 Hz for noise and shock response measurement DEWE-51-USB2-32 2x MDAQ-SUB-BRIDGE-D, 2x MDAQ-SUB-ACC-A modules and USB-A/D converter BW: 300 kHz 4 / 8 mA HP: 0.16 Hz BW: 300 kHz 4 / 8 mA HP: 0.16 Hz, 3.4 Hz Typical combination with two SUB modules mounted on a BASE module, and FILTER board (optional) All MDAQ boards are equipped with highest quality components www.de we t ron .com # CH 16 Filter characteristics Butterworth Cut-off frequencies 100 Hz, 1, 10, 30, 100 kHz, Bypass Order th 4 Note: not possible in all system configurations. Please contact factory for details. 16 Butterworth 30, 100, 300 Hz, 1, 10 kHz, Bypass 2 MDAQ-FILT-5-BU-S1 16 Butterworth 100 Hz, 1, 10, 30, 100 kHz, Bypass 2 MDAQ-FILT-5-BE 16 Bessel 30, 100, 300 Hz, 1, 10 kHz, Bypass 2 TRION Systems nd MDAQ-FILT-5-BU nd MDAQ-SUB-V-200-D DAQP-STG-D DAQP-LV-D HSI-LV - - - Isotron (constant current powered) adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector Excitation current 4 mA at 21 V, High pass filter 1.5 Hz, BNC connector Bandwidth and ranges are defined by connected amplifier Automatic adapter identification - - - 200 V input adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector Differential input configuration, BNC connector Bandwidth and ranges are defined by connected amplifier Automatic adapter identification MSI-BR-RTD - not needed - - Pt100, Pt200, Pt500, Pt1000 and Pt2000 adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector 2, 3 and 4 wire connection methods, 5-pin Binder 712 series connector Automatic adapter identification MSI-BR-CH-x - - - Charge input interface for DAQP-STG and MDAQ-SUB-BRIDGE / -STG with DB9 connector Range up to 50000 pC, AC coupled with 0.07 Hz, BNC signal connection Max. 100 kHz bandwidth (dependent on the max. bandwidth of the amplifier) Automatic adapter identification MSI-BR-TH-x - isolated TC sensor - - any TC sensor Thermocouple type K / J / T adapter for DAQP-BRIDGE-x and MDAQ-SUB-BRIDGE / -STG modules with DB9 connector For use with isolated thermocouple sensors only ! (except in combination with DAQP-BRIDGE-A*) High accuracy cold junction reference measurement, 1 m thermo cable with Mini TC connector Automatic adapter identification MSI-V-ACC - - Isotron (constant current powered) adapter for DAQP-LV and MDAQ-SUB-V-200 modules with DB9 connector Excitation current 4 mA at 21 V, High pass filter 1.5 Hz, BNC connector Bandwidth and ranges are defined by connected amplifier Automatic adapter identification MSI-V-RTD - - Software MSI-BR-V-200 CVT Logger MDAQ-SUB-STG-D Dedicated Instruments Modular Smart Interfaces for HSI, DAQP and MDAQ modules Front-ends ORION Systems nd MSI Series MSI-BR-ACC About us Filter modules for MDAQ Module MDAQ-AAF4-5-BU Pt100, Pt200, Pt500 and Pt1000 adapter for DAQP-LV and MDAQ-SUB-V-200 modules with DB9 connector 2, 3 and 4 wire connection methods, 5-pin Binder 712 series connector Automatic adapter identification 21 All-in-one ORION Built-in display Powerful PC inside for fast online displays and analysis Most convenient for mobile applications DEWE-2600 DAQ / PAD amplifier slots MDAQ amplifier input channels DEWE-5000 16 16 Up to 80 Up to 32 Combined DAQ / PAD slots 16 DAQ / PAD and MDAQ input channels up to 32 MDAQ Total PCI slots Available with DAQ / PAD slots 7 5 4 5 High-speed channel expansion Low-speed channel expansion 100 Hz DEWE-50-PCI Front-end or DEWE-30 CPAD3, requires CAN interface in base unit Quasi-static channel expansion EPAD2 Data storage 1 TB hard disk Optional data storage Display n/a Up to 480 GB SSD 15“ (1280 x 1024) 17“ (1920 x 1080) FULL HD Power supply Standard rated (max.) Option 95 to 260 VAC 95 to 260 VAC Battery powered, 3 battery slots for ~2 hours operation Dimensions Dimensions (W x D x H) 417 x 246 x 303 mm (16.4 x 9.6 x 11.9 in.) 460 x 351 x 192 mm (18.1 x 13.8 x 7.7 in.) Weight without batteries1) Typ. 14 kg (31 lb.) Typ. 17 kg (37.4 lb.) 1) Weight of one battery: 660 g (1.45 lb.) DEWE-2600 shipping and carrying case 22 DEWE-5000 with batteries DEWE-2600 car seat mounting kit www.de we t ron .com DEWE-571 - Up to 32 Up to 16 Up to 16 n/a 2 1 1 1 n/a n/a DEWE-30 n/a DEWE-50-PCI Front-end or DEWE-30 CPAD3, requires CAN interface in base unit EPAD2 120 GB Solid State Disk 120 GB Solid State Disk Up to 1 TB SSD Up to 480 GB SSD Up to 480 GB SSD 15“ multitouch-screen (1280 x 800) 13“ (1280 x 800) 12“ touchscreen (1280 x 800) 95 to 260 VAC 8 to 30 VDC, incl. external AC power supply Battery powered, 2 battery slots, 2 batteries for ~2 hours operation incl., incl. external AC power supply 8 to 30 VDC incl. external AC power supply DEWE-UPS-150-DC (ext. battery pack, 2 battery slots) n/a 462 x 320 x 135 mm (18.2 x 12.6 x 5.3 in.) 317 x 252 x 110 mm (12.5 x 9.9 x 4.3 in.) 360 x 300 x 150 mm (14.2 x 11.8 x 5.9 in.) Typ. 8.2 kg (18 lb.) Typ. 5.5 kg (12.1 lb.) Typ. 5 kg (11 lb.) Software 1 TB hard disk Front-ends - CVT Logger DEWE-1201 16 Dedicated Instruments DEWE-3300 ORION Systems TRION Systems About us All-In-One DW2-UPS-150-DC, 130 W UPS with 2 slots for batteries DEWE-2600 customized version DEWE-POW-24-350 23 Mainframes ORION Portable and rack-mount versions Powerful PC inside for fast online data view & analysis Many power supply options DEWE-800 series DEWE-510 series DAQ / PAD amplifier slots 16 MDAQ amplifier input channels Combined DAQ / PAD slots and MDAQ input channels Total PCI slots Available with DAQ / PAD slots Up to 64 n/a 16 DAQ / PAD, up to 32 MDAQ (BNC only) 5 3 5 High-speed channel expansion Low-speed channel expansion 100 Hz Quasi-static channel expansion 3 DEWE-50-PCI Front-end or DEWE-30 CPAD3, requires CAN interface in base unit EPAD interface with up to 16 EPAD2 modules = 128 ch Data storage 1 TB hard disk Optional data storage Up to 480 GB SSD Power supply Standard (max.) 95 to 260 VAC 9 to 18 VDC or 18 to 36 VDC Battery powered, 3 battery slots 3), 2 batteries for ~2 hrs. operation incl., incl. external AC power supply optional external DC power supply Dimensions (W x D x H) 437 x 443 x 181 mm (17.2 x 17.4 x 7.1 in.) 439 x 308 x 181 mm (17.2 x 12.1 x 7.1 in.) Weight without batteries1) Typ. 12 kg (26.4 lb.) Typ. 8 kg (17.6 lb.) Optional Dimensions 1) Weight of one battery: 660 g (1.45 lb.) DEWE-800 with 19” mounting kit 24 POWERBOX-12 Power distribution for automotive applications DEWE-DCDC-24-300-ISO 10 to 36 VDC power supply 24 VDC (300 W) www.de we t ron .com Megawattlabor am Fraunhofer ISE, Freiburg ©Fraunhofer ISE DEWE-501 series ORION Systems TRION Systems About us Mainframes DEWE-211 series n/a n/a 3 1 n/a n/a Setup network CPAD3, requires CAN interface in base unit EPAD interface with up to 16 EPAD2 modules = 128 ch 120 GB Solid State Disk Up to 480 GB SSD 8 to 30 VDC, incl. external AC power supply External DC power supply Stackable battery-pack for ~2 hrs. operation with wide range DC input 439 x 209 x 181 mm (17.2 x 8.2 x 7.1 in.) 317 x 252 x 92 mm (12.4 x 9.9 x 3.6 in.) Typ. 6 kg (13.2 lb.) Typ. 5 kg (11 lb.) Software Battery powered, 2 battery slots 3), 2 batteries for ~2 hrs. operation incl., incl. external AC power supply CVT Logger Front-ends Up to 16 Dedicated Instruments Up to 64 Battery charger BAT-CHARGER-1 (range: 90 to 260 VAC) Battery charger BAT-CHARGER-4 (range: 90 to 260 VAC) The carrying bag is included as standard accessory 25 PCI Front-ends ORION High speed PCIe connection to your computer or laptop Up to 128 ch per chassis Cascading option for creating high channel count systems DEWE-50-PCI-16 DEWE-50-PCI-32 DEWE-51-PCI-64 Slots for DAQ or PAD modules 16 32 n/a n/a MDAQ input channels n/a n/a Up to 64 Up to 128 External quasi-static channel expansion DEWE-51-PCI-128 EPAD interface, up to 16 EPAD2 modules = 128 ch Digital I/O, counter, CAN bus Depending on selected ORION board(s) Main system Internal PCI slots 1 Host PC interface 3 Supported operating systems Power supply (max.) Dimensions (W x D x H) Weight 7 13 ExpressCard-54, optional PCI, PCI-Express or ExpressCard-34 Microsoft® WINDOWS® 7 95 to 260 VAC 95 to 260 VAC 95 to 260 VAC 95 to 260 VAC 435 x 245 x 133 mm (17.1 x 9.6 x 5.2 in.) 435 x 300 x 223 mm (17.1 x 11.8 x 8.8 in.) 435 x 300 x 177 mm (17.1 x 11.8 x 7.0 in.) 435 x 300 x 267 mm (17.1 x 11.8 x 10.5 in.) Typ. 6 kg (13 Ibs) Typ. 10 kg (22 Ibs) Typ. 6 kg (13 Ibs) Typ. 9 kg (20 Ibs) Environmental specifications Operating temperature 0 to +50 °C Storage temperature -20 to +70 °C Humidity 10 to 80 % non cond., 5 to 95 % rel. humidity Vibration EN 60068-2-6, EN 60721-3-2 Class 2M2 Shock EN 60068-2-27 The use of multiple DEWE-50-PCI on a single notebook is supported; ending up in a very flexible multi-channel system 26 Easy PCI connection with laptop computers www.de we t ron .com About us USB & Ethernet Front-ends Easy USB or Ethernet connection to your computer DEWE-50-USB2-16 DEWE-50-NET-16 8 16 16 EPAD interface, up to 8 EPAD2 modules = 64 ch EPAD interface, up to 16 EPAD2 modules = 128 ch A/D conversion Sampling method Resolution Sampling rate Simultanous sampling Multiplexed sampling 24 bit 16 bit Multiplexed sampling 16 bit 204.8 kS/s 500 kS/s aggregate 31.25 kS/s per channel 500 kS/s aggregate 31.25 kS/s/ch @ 16 AI 29.41 kS/s/ch @ 16AI + DI 26.31 kS/s/ch @ 16AI + DI + 1 counter 18.51 kS/s/ch @ 16 AI + DI + 5 counter 2 counters or 6 digital inputs Optional 5 isolated counters / 16 TTL level DI 2 - - 9 to 36 VDC 95 to 260 VAC 85 to 264 VAC Counter and digital inputs Counters / digital inputs CAN bus High-speed CAN bus interfaces Power supply Standard (max.) Main system Host PC interface Supported operating systems Dimensions (W x D x H) Weight USB 2 USB 2 100 Mbit Ethernet Microsoft® WINDOWS® 7 Microsoft® WINDOWS® 7 Microsoft® WINDOWS® 7 / 8 230 x 181 x 104 mm 9.1 x 7.1 x 4.1 in. 435 x 245x 133 mm 17.1 x 9.6 x 5.2 in. 435 x 245 x 133 mm (17.1 x 9.6 x 5.2 in.) Typ. 3 kg (6.6 lbs) Typ. 5.5 kg (12 Ibs) Typ. 5.5 kg (12 Ibs) Environmental specifications Operating temperature 0 to +50 °C Storage temperature -20 to +70 °C Relative humidity 5 to 95 % rel. humidity (10 to 80 % non cond.) Vibration EN 60068-2-6, EN 60721-3-2 class 2M2 EN 60068-2-27 Software Shock Front-ends External quasi-static channel expansion DEWE-50-USB2-8 CVT Logger Slots for DAQ or PAD modules Dedicated Instruments Various power supply options ORION Systems TRION Systems Sync option for channel expansion (some models) Carrying handle DEWE-50-DC option for DC power supply USB interface with hot plug-and-play capabilities 16 BNCs on the rear for conditioned signal output 19“ rack mount kit 27 CPAD3 *) 100 Hz sampling rate High isolation 1500 V ADC per channel Module CPAD3-TH8-x CPAD3-V8 Input type Dedicated modules for type J, K, T Universal module for types K, J, T, E, R, S, B, N, C, U 8 isolated voltage input channels Input ranges According thermocouple type Isolation 1500 VDC (channel to channel and channel to BUS, power and chassis) Special Overvoltage protection: 15 VDC Physical input range: ±50 V Software selectable: ±100 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V 1500 VDC (channel to channel and channel to BUS, power and chassis) Overvoltage protection: 350 VDC CPAD3-TH8-x Intelligent amplifier with integrated A/D conversion CAN interface 8 input channels for thermocouples Available thermocouple types: CPAD3-TH8-x: K, J, T standard type CPAD3-TH8-UNIVERSAL: Universal type CPAD3-V8 Intelligent amplifier with integrated A/D conversion CAN interface 8 isolated voltage input channels CPAD3-V8 LEMO version * CPAD = CAN-Bus interface 28 * EPAD = RS-485 interface www.de we t ron .com About us *) Extremely rugged and flexible mounting Input ranges According thermocouple type Isolation 350 VDC (channel to channel and channel to BUS, power and chassis) Special Overvoltage protection: 15 VDC Overvoltage protection: 350 VDC EPAD2/CPAD2-V8 8 isolated voltage input channels Physical input range: ±50 V Software selectable: ±100 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V 350 VDC (channel to channel and channel to BUS, power and chassis) EPAD2/CPAD2-RTD8 8 isolated Resistance Temperature Detector channels Resistor: 0 to 999.99 Ω RTD: PT100(385), PT200 (385), PT500(385), PT1000 (385), PT2000(385), PT100 (3961) 350 VDC (channel to channel and channel to BUS, power and chassis) EPAD2/CPAD2-LA8 8 isolated current inputs 0 to 20 mA, ±20 mA, ±30 mA EPAD2-USB USB-interface module for EPAD2 n/a Module EPAD2-AO4 Output type 4 voltage or current output channels Output ranges ±10 V; ±5 V; 0 to 5 V; 0 to 10 V; 0 to 20 mA; 4 to 20 mA Overvoltage protection: 15 VDC 350 VDC (channel to channel and channel to BUS, power and chassis) Overcurrent protection: 70 mA cont. - - Isolation Special 350 VDC (channel to BUS, power and chassis) - Front-ends Input type Dedicated modules for type J, K, T Universal module for types K, J, T, E, R, S, B, N, C, U CVT Logger Module EPAD2/CPAD2-TH8-x Dedicated Instruments Channel to channel/system isolation ORION Systems TRION Systems 24 bit A/D converter per channel, 12 Hz sampling rate Software EPAD2/CPAD2 29 CVT Logger USB data logger for current, voltage and temperature inputs Touch operation and easy to use software 8 to 40 channels, 24 bit, up to 12 Hz Packages Each package contains: CVT Logger software, interface module, and power supply (24 V). EPAD modules of your choice must be selected (bricks of 8 channels). Depending on application, CVT Logger is delivered stacked, or separated for distributed measurements. For distributed systems cable length between the modules can be selected (2 m, 5 m, 10 m). Package EPAD modules Input channels CVT-Logger 8 1 8 CVT-Logger 16 2 16 CVT-Logger 24 3 24 CVT-Logger 32 4 32 CVT-Logger 40 5 40 EPAD modules Module Input type Input ranges Isolation Universal module for types K, J, T, E, R, S, B, N, C, U According thermocouple type 350 VDC (channel to channel and channel to BUS, power and chassis) 8 isolated Resistance Temperature Detector channels Resistor: 0 to 999.99 Ω RTD: PT100(385), PT200 (385), PT500(385), PT1000 (385), PT2000(385), PT100 (3961) 350 VDC (channel to channel and channel to BUS, power and chassis) 8 isolated current inputs 0 to 20 mA, ±20 mA, ±30 mA 0 to 20 mA, ±20 mA, ±30 mA 8 isolated voltage input channels Physical input range: ±50 V Software selectable: ±100 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V 350 VDC (channel to channel and channel to BUS, power and chassis) EPAD2/CPAD2-TH8-x EPAD2/CPAD2-RTD8 EPAD2-LA8 EPAD2/CPAD2-V8 30 www.de we t ron .com About us Power Network Analyzers DEWE-638-PNA DEWE-838-PNA-P 4 voltage 4 current (up to 12) 4 voltage 28 current 4 voltage 4 current 4 voltage 4 current - - - - Signal conditioning Current clamps / coils included External quasi-static channel expansion Internal 4x PNA-FLEX-300-45 - Option PAD-BOX Input specifications Voltage range ±1400 V peak Bandwidth of input amplifiers DC to 300 kHz Direct current input 5A Maximum input current via clamps Depending on clamps - 10000 A - Maximum input current via flexible coils A/D conversion Sampling rate 571/561-PNA: 250 kS/s aggregate 571/561-PNA-1MS: 1 MS/s/ch 1 MS/s aggregate 10 kS/s 10 kS/s 3 opt. 2 - - Solid State Disk SD Card Solid State Disk 120 GB 2 GB 2 GB Resolution 16 bit Digital I/O Digital I/O, TTL level 2x DIN (24 V max.) and 1x DOUT (Relais, normal open, 60 V / 1 A AC max.) Functions Accuracy classification Wide band power analysis IEC 61000-4-30 Class A DEWE-571-PNA-1MS: 1 MS/s - Data storage 1) Technology Capacity Main system 1) Display 12“ TFT (1280 x 800) touch Processor Intel® Core™ i5 Interfaces 2x USB, 1x Ethernet, 1x RS-232 - - Low power CPU 1x USB, 1x Ethernet, 1x RS-232 1x USB, 2x Ethernet, 1x RS-232 Power supply Standard Version 571-PNA: Battery powered, 2 battery slots 2), 85 to 265 VAC 50 / 60 Hz 95 to 260 VAC 50 / 60 Hz 2 batteries for ~2 hrs. operation incl., incl. external AC power supply internal 10 - 36 VDC (internal 10 to 36 VDC) Version 561-PNA: 95 to 260 VAC 50 / 60 Hz Dimensions Dimensions (W x D x H) 360 x 300 x 150 mm (14.2 x 11.8 x 5.9 in.) 200 x 150 x 75 mm (7.9 x 5.9 x 3 in.) 160 x 166 x 125 mm (6.2 x 6.5 x 4.9 in.) Weight without batteries Typ. 5 kg (11 lb.) Typ. 2.5 kg (5.5 lb.) Typ. 2 kg (4.4 lb.) 1) Front-ends DEWE-561-PNA-4U28I CVT Logger Dynamic analog input channels DEWE-571-PNA Dedicated Instruments Power rating, harmonics (including 2-9 kHz), interharmonics, Flicker, symmetrical components, frequency, DISDIP/Unipede statistics, CBEMA/ITIC curve Software IEC61000-4-30 Class A ORION Systems TRION Systems EN50160 Please find current specifications in the latest price list 2) Weight of one battery: 660 g (1.45 lb.) 31 Power Fault Recorders Monitoring of power supply systems Power plant testing and monitoring High, medium and low voltage systems Fault recording, harmonics, flicker, power flow, DIP measurements, database storing GPS synchronisation, remote control, EN50160, ITIC (CBEMA), UNIPEDE Dynamic analog input channels DEWE-818-PFR DEWE-821-PFR DEWE-820-PFR-16 DEWE-838-PNA-V Up to 48 voltage or current with DEWE-30-16-PFR Up to 12 voltage and 12 current 16 slots for DAQP modules 3 voltage Ext. quasi-static channel expansion EPAD interface, up to 16 EPAD2 modules = 128 ch - Input specifications Voltage range ± 1400 V peak Bandwidth of input amplifiers DC to 300 kHz Direct current input 5A Max. input current via clamps Max. input current via flexible coils Depending on clamps - 3000 A - A/D conversion Sampling rate 250 kS/s aggregate Resolution 10 kS/s 16 bit Digital I/O and counters Digital I/O, TTL level Data storage 8 / 16 / 24 8 / 16 / 24 8 / 16 / 24 - 1) Technology Hard disk SSD Capacity 1000 GB 2 GB Main system 1) Intel® Core™ i7 Low power CPU 4x USB, 2x Ethernet, 1x RS-232 1x USB, 2x Ethernet, 1x RS-232 Standard 95 to 260 VAC 50 / 60Hz or 110 / 220 VDC 95 to 260 VAC 50 / 60 Hz (internal 10 to 36 VDC) Optional 48 / 110 V - Processor Interfaces Power supply Dimensions Housing Dimensions (W x D x H) Weight 1) 32 DEWE-818-PFR: 19” rack-mount, 4U DEWE-30-16-PFR: 19” rack-mount, 3U DEWE-818-PFR: 437 x 304 x 181 mm (17.2 x 12 x 7.1 in.) DEWE-30-16-PFR: 437 x 133 x 245 mm (17.2 x 17.4 x 7.1 in.) DEWE-818-PFR: 12 kg (26.4 lb.) DEWE-30-16-PFR: 6 kg (13.2 lb.) 19” rack-mount, 4U 19” rack-mount, 4U Counter panel mount chassis wall mount DIN rail 437 x 443 x 181 mm (17.2 x 17.4 x 7.1 in.) 437 x 443 x 181 mm (17.2 x 17.4 x 7.1 in.) 160 x 166 x 125 mm (6.2 x 6.5 x 4.9 in.) Typ. 12 kg (26.4 lb.) Typ. 12 kg (26.4 lb.) Typ. 2 kg (4.4 lb.) Please find current specifications in the latest price list www.de we t ron .com About us Power Measurement RPM and torque measurement, determination of efficiency factor Harmonics analysis, record of dynamic processes Examination of rotating field, hybrid cars and alternative drive systems DEWE-2600-PM-1000 DEWE-5000-PM-1000 DEWE-2600-PM-1000-8: 8 DEWE-2600-PM-1000-16: 16 DEWE-5000-PM-1000-8: 8 DEWE-5000-PM-1000-16: 16 4 x HSI-HV and 4 x HSI-LV-D Included DAQP modules at 16 channel units 8 x HSI-HV and 8 x HSI-LV-D Bandwidth of input amplifiers DC to 2 MHz External quasi-static channel expansion EPAD interface, up to 16 EPAD2 modules = 128 ch A/D conversion Sampling method Sampling rate / channel Simultaneous sampling 0.1 / 1 / 5 MS/s Resolution 0.1 / 1 / 5 / 10 MS/s 0.1 / 1 / 5 MS/s 16 bit Digital I/O, TTL level CVT Logger Digital I/O and counters 8 Counters or digital inputs, TTL level (1 counter equals 4 digital inputs) 2/8 CAN bus option UP-CAN-2 optional 2 high-speed CAN bus interfaces Video input option UP-DEWE-CAM-01 adds synchronized video picture acquisition, up to 70 fps at 640 x 480 pixel Data storage 1) Technology Hard disk Capacity Max. gap free storing to disk Typ. duration of recording (16 ch. / 10 kS/s/ch. / 16 bit) Main system 1000 GB 1000 GB 1000 GB Typ. 70 MB/s Typ. 80 MB/s Typ. 70 MB/s 35 days 20 days 35 days - 15” TFT (1280 x 800) 1) Display Processor 17” TFT (1920 x 1080) FULL HD Intel® Core™ i7 Current transducer power supply 9 V 8 x lense for 9 V and ±15 V Interfaces 4x USB, 2x Ethernet, 1x RS-232 Power supply Standard 95 to 260 VAC 50 / 60Hz 110 / 220 VDC Battery powered, 3 battery slots 2), 3 batt. for ~2 hrs. operation incl., incl. external AC power supply 95 to 260 VAC 50 / 60Hz 110 / 220 VDC Optional - 95 to 260 VAC 50 / 60Hz or 110 / 220 VDC - Dimensions Housing 19” rack-mount, 4U Portable instrument Portable instrument Dimensions (W x D x H) 437 x 443 x 181 mm (17.2 x 17.4 x 7.1 in.) 417 x 246 x 303 mm (16.4 x 9.6 x 11.9 in.) 460 x 351 x 192 mm (18.1 x 13.8 x 7.7 in.) Weight without batteries Typ. 12 kg (26.4 lb.) Typ. 14 kg (31 lb.) Typ. 17 kg (37.4 lb.) 1) Dedicated Instruments Included DAQP modules at 8 channel units Front-ends DEWE-820-PM-1000 DEWE-820-PM-1000-8: 8 DEWE-820-PM-1000-16: 16 Software Dynamic analog input channels ORION Systems TRION Systems Wideband power analysis, engine test benches, transformer tests Please find current specifications in the latest price list 33 Marlin Software for Power Monitoring Applications Fault Analysis, PQ and Energy Monitoring Marlin is THE solution for electrical power engineering. The recording of disturbances in power networks, the calculation of all power quality parameters and the measurement of performance and energy flows are the main tasks that MARLIN performs. The software can be run as a native Windows service in the background, and unauthorized access to the instruments without user credentials is not allowed. On small DEWE devices, such as the DEWE-638 and DEWE-838 series, Marlin runs as a Linux service. Measurement and Evaluation at the same time - Access from multiple workstations The user interface is a pure web application and therefore allows the control and evaluation of each workstation in the network. Access via a browser independent operating system is possible from all devices such as tablet computers, smart phones, and any computer workstation. Therefore, the data can be viewed by multiple users simultaneously, from any location. Integration into your control system If you prefer to have the data in your control system, direct access of the data can be achieved using IP/ URL technology. If you prefer to access the standardized IEC 60870-5-104 protocols, please use the “MARLIN APP Scada 104” application. Vector diagram at the Start Screen (see above) Vector scope for 3-phase systems Every harmonic can be shown Display of multiple vector scopes on the same screen via web browser technology Measurement parameters In addition to all aspects of 3-phase current and voltage, parameters that can be measured include harmonics, flicker, frequency and symmetrical components. Triangle, star, and combined networks Disturbance recorders can be used in all network levels. Besides the classic star circuit with neutral, a measurement in a triangle or a calculation of the lineto-line parameters is possible. A proper measurement strictly according to the EN50160 standard in medium and high voltage networks, in which the transducers are connected in star, the assessment must be made line to line. For two-phase systems and frequencies other than 50/60 Hz, there are also available settings. Several power modules at once Recording of the above parameters can be performed in parallel by multiple virtual devices. It can simultaneously measure current and voltages from summed feeders, as well as a 3-phase configuration. 34 www.de we t ron .com Statistics by DISDIP online Adjustable number of harmonics THD calculation Limit manager (.e.g., IEC 61000-2-4, EN 50160…) Alarm List Device messages Error messages Performance & PQ Analysis (IEC 61000-4-30 Class A) Diagram: star, with triangular rating, triangle, single and 3-phase Trigger settings U, I, f, P Power band: star, delta, earth voltage Regulation: star, delta, earth voltage Phase 4 as earth voltage / star power Frequency hopping Frequency measurement, fundamental frequency selectable Power band: phase center P, Q, S, PF, P1, Q1, cosine Phi (each 3 ~ and phase values) Active and reactive power changes (single and 3-phase) Harmonics, THD (IEC 61000-4-7) Flicker (IEC 61000-4-15) Power factor changes (single and 3-phase) 50160 on-line analysis Symmetrical components Star or delta Signal voltage level Change in current: phase center About us FFT for P - power direction determination TRION Systems List form ORION Systems Duration, altitude and time of the fault FFT for U and I according to IEC 61000-4-7 Front-ends Online Fault statistics FFT - harmonic analysis CVT Logger Zoom in and zoom back during the measurement! Reporting of the nature and time of the fault Dedicated Instruments Recording of all parameters in adjustable intervals Online fault list Software Recorder 35 LabVIEW ™ library LabVIEW™ is a graphical programming platform that helps engineers scale from design to test and from small to large systems. It offers unprecedented integration with existing legacy software, IP, and hardware while capitalizing on the latest computing technologies. LabVIEW™ provides tools to solve today’s problems and the capacity for future innovation - faster and more effectively. LabVIEW™ software is ideal for any measurement or control system. Integrating all the tools that engineers and scientists need to build a wide range of applications in dramatically less time, LabVIEW™ is a development environment for problem solving, accelerated productivity, and continual innovation. We offer a comprehensive driver library for all DEWETRON systems and components, accessible as palette in the user library, as it is usual in LabVIEW™. Instruments Signal conditioning Modules DEWE-ORION multifunction A/D boards Linux support The DEWETRON TRION™ modules also can run under a Linux environment (CentOS, Ubuntu and compatible distributions). Like all LabVIEW™ code, also the DEWETRON LabVIEW™ libraries are platform independent and can be used on Linux as well. Trion™ PXI measurement modules 36 Low level virtual instruments Sample virtual instruments Using low level vis you can create your own project from scratch. Use them to access every single feature of the multifunction ADC board, incl. but not limited to sample rate, input ranges, AI channels, digital I/O, counter, onboard RS-485 interface, CAN bus interface etc For easier understanding or to expedite the development process you might utilize one of the supplied examples. www.de we t ron .com About us NItrogen TRION Systems Proprietary software or own programming? When proprietary COTS software is not suitable for your measurement application, there is no way around own programming. But starting a software development project from zero is timeconsuming, expensive and error prone. Do not reinvent the wheel ORION Systems The DEWETRON Open Systems Software framework NItrogen saves you from these problems. Written in National Instruments LabVIEW™, one of the most popular development languages in the world of test and measurement, NItrogen is dedicated to all faithful LabVIEW™ programmers. The source code is included in the premium package. This makes NItrogen a ready to use software framework for your own development project. Program only what is specific for you Front-ends You can instantly use the software framework as it is, delete whatever is dispensable, add or integrate your own code and finalize your software project from an “80% level” onwards. Get started instantly! All you need to modify or extend the program is a valid license LabVIEW™ FDS or PDS license. Software NItrogen consists of a core program and a range of client vis. The core serves as setup tool for the hardware and reads the data from the hardware. The client vis are individual windows (within the work space or undocked, even on a different display) and will receive the scaled data for visualisation, processing, storage, analysis or other purposes, even if they are not related to the data flow. They can be started in multiple instances which allows i.e. saving data to multiple files at the same time, at different file formats and locations. Extend the collection of clients with your own client vis for your personal needs. Dedicated Instruments CVT Logger Get the source code ... remain independent! 37 DASYLab Drivers for Signal Conditioning Modules and ORION-based Instruments DEWETRON provides the complete measurement chain in DASYLab. While the DAQP and PAD amplifier series are supported since DASYLab 5, the AD-gap is now filled with the ORION-DAQ (16-bit series) driver. The simultaneous sampled analog inputs, synchronous digital inputs and counters, sampling rates up to 5 MHz will give the complete picture of the investigated device. DEWETRON drivers and DASYLab run on Windows 32 and 64 bit. AD input The DASYLab driver supports the whole ORIONDAQ (16-bit) series. Also multiple AD cards can be combined to extend channels. The smart driver architecture does automatic hardware synchronisation of multiple cards. ORION-1616-100 ORION-3216-100 ORION-1616-500 ORION-0816-1000 ORION-1616-1000 ORION-0816-5M DAQP series modules PAD modules Digital and counter inputs The ORION-DAQ (16-bit series) card also supports synchronous digital and counter inputs. Digital and counter inputs are read with the selected sampling rate. Compared to other AD cards where this is read asynchronous, this feature enables that fast digital channels can be measured with the full sampling rate. The outstanding digital input filter of the ORION counters will support measurements at harsh electrical environments. Basic event counting Gated event counting Up down counting Basic encoder 38 www.de we t ron .com About us Operating systems WIN XP, 32-bit CVT Logger DAQP scaling and programming module, and the PAD module are completing the whole input measurement chain. The DEWETRON scaling module is used to program the DAQP modules (range, filters, ...) and rescale to amplifiers input range. PAD input blocks are used to read data directly from the PAD amplifiers. Dedicated Instruments DAQP and PAD modules Front-ends ORION Systems The ORION cards also support external clock and trigger, which is usefully to synchronize to other clock sources, or to rotary encoders to change into order domain world. Two free programmable clockout channels, can be used to sync other devices. TRION Systems Clock, trigger and clockout WIN 7, 64-bit Software WIN 7, 32-bit 39 DS-7 for turn-key R&D Applications DEWETRON customers in the R&D world don’t want to write software, or run on LINUX - they just want a turn-key software application that can be used within minutes. DEWESoft™ (DS-7 for short) is a great package that perfectly supports most DEWETRON hardware. Runs under Windows DS-7 was written specifically for Windows, and does not run on any other operating system. But that’s perfectly fine for test and measurement specialists in the research sector. Data acquisition systems used in this sector are typically used for something different all the time, and flexibility is more important than long-term stability. The feature set provided by DS-7 is truly impressive. You can acquire high speed (dynamic) data from DEWETRON ORION and TRION series hardware (plus all of our signal conditioners), as well as hundreds of channels of asynchronous data from CAN, ARINC, 1553, SERIAL, and more. Easy visualization One of the most popular aspects of DS-7 is how easy it makes it for you to arrange the screens just the way that you like them. It provides recorder graphs, scopes, analog and digital meters, 2D and 3D graphs, tabular displays, text objects, X-Y graphs, and more. Place them in any arrangement and assign the channels into them that you want. DS-7 makes that very fast and easy. The entire setup is saved, so you can create countless configurations and recall them in a matter of seconds. MATH functions DS-7 includes a rich set of pre-made MATH functions that you can apply to your data DURING recording, or AFTER recording. These include programmable filters, integration, FFT analysis, and so much more. When the computer is not powerful enough to handle what you want to do in real-time, you can set any or all of the MATH functions to be processed after recording. DS-7 is not as powerful as a real analysis tool such as Flexpro or Matlab, but it’s pretty darn good for the money. 40 Exporting and Printing A wide variety of export filters are included, for all of the most popular analysis tools - even Excel! And you can print your data in full color to any attached Windows printer, or to a PDF document that can be printed from another computer. www.de we t ron .com 64-Bit Integers and pointers to 64-bit Integers Pointers to zero-terminated ASCII-Strings (no Unicode/Wide string Support) All public interface functions are accessible by using the Standard C. Therefore, any programming language that allows the above mentioned perqui sites can exploit the functionality of the API. DEWE2 Explorer included If you’re using the TRION hardware, the API will install a DEWE2 Explorer application (delivered standard with all DEWE2 systems). Besides providing in-depth system infor- mation, this tool enables users to run self-tests of TRION modules, enable logging files in case of errors and to easily upgrade the firmware of TRION modules. The explorer can also create a virtual system in addition to the real one, to aid you in programming your own application even without the real hardware. About us TRION Systems ORION Systems 32-Bit Integers and pointers to 32-bit Integers Front-ends The DEWETRON TRION SDK is shipped with the necessary interface files for C/C++ (.h -Files) and Pascal-dialects like Delphi (.pas – Files) Using these files, direct integration into the application can be achieved by including them. But this is not the limit, because many languages are supported indirectly. All public Interface functions use the “std-call” calling convention. And all public interface functions accept the following primitive data-types: CVT Logger If your prefer to write your own program code in C, C++, C#, Visual Basic, Python or Java, our SDK for TRION is available for you. Dedicated Instruments Software Development Kit Software DEWETRON OEM 41 Accessories Carrying cases and transportation systems are available for all systems. FireWire and Ethernet cameras; Split-box for supplying and connecting Ethernet cameras Car seat mounting kits for our mobile systems GPS based speed and displacement sensor Power supplies, battery and distribution boxes Several solutions for current measurement from simple shunts to current clamps and high-precision zero flux transducers. Encoders for combustion analysis and torsional and rotational vibration applications 42 www.de we t ron .com Combustion Analysis Road Load Data Basic Brake Test Vehicle Dynamics Adaptive Cruise Control Torsional & Rotational Vibration E-Mobility Race Car Energy & Power Analysis Systems & Components E-Mobility Power Measurement Power Network Analysis Power Fault Recording Flight Test Engine Test Aerospace & Defense TRION Systems Automotive ORION Systems Functional Safety About us Measuring Batteries Wind Tunnel Test Maintenance Safety Equipment Cabin Comfort Front-ends Applications Hybrid Testing System Integration Lab Noise and Vibration Tactical/Land Vehicle Transportation Structural Test CVT Logger Component Test Modal Test Noise Origin Current Collector Test on Trains Power supply of railway systems Mixed Signal Recorder Dynamic Signal Analyzer Balancing Strobe Cam Order Tracking Modal Analysis Torsional & Rotational Vibration Software General Test & Measurement Dedicated Instruments PCM Telemetry Transient Recorder Distributed Systems 43 MAINTENANCE CALIBRATION HELP DESK TRAINING UPGRADE DE-B131101E • All trademarks are acknowledged to be the property of their owners. Specification subject to change without notice. © DEWETRON GmbH 04/2015 CUSTOMER CARE CENTER DEWETRON GmbH • Parkring 4 • A-8074 Grambach • Tel +43 (0)316 3070 0 • Fax +43 (0)316 3070 90 • info@dewetron.com