"THE RUGGED ONE" SURFACE OR FLUSH MOUNT
Transcription
"THE RUGGED ONE" SURFACE OR FLUSH MOUNT
"THE RUGGED ONE" SURFACE OR FLUSH MOUNT MOTION DETECTOR WI STEEL FACEPLATE & SU'RFACEMOUNTING BOX - Model ERGD..1 n ~ ;.~ 6~!'tiHi;~ n1i.l'-. r Dual element PIR Rugged steel housing Selectable LEDindicator light 12 volt or 24 volt DC power input 5 Amp form "C" (N.O./N.C.)contacts Built-in adjustable relay timer (Approx. 3-30 sec.) Can flush mount to 1900 electrical box or surface mount with angle box included THANK YOU FOR PURCHASING THIS UNIT. FOR OPTIMUM PERFORMANCE, PLEASE READ AND FOLLOW THESE INSTRUCTIONSCAREFULLY Mounting: A specially designed steel surface mounting box is supplied with the unit and is angled for high/low and left/right mounting angles. It may also be either surface or flush mounted on a wall using #1900 electrical box with dual gang adaptor cover. When choosing a mounting position for this unit, please take the following into account: Be sure unit has clear line of sight to area to be protected Avoid aiming unit at areas wI heating/cooling vents or ducts Avoid aiming unit at areas of direct sunlight Avoid aiming unit at devices with active heating elements (For detection pattern see figure D.) Power options: - This unit compatible is with a wide range of equipment alarm systems, access controls, electric locks, video event recording systems, etc.. Jumper J2 (#2 on figure A) controls input voltage of either 12 or 24 vdc. If the jumper is left in place (Factory setting), the unit is set for 12 volt power; if removed it is set for 24 volt power. Polarity MUST be observed see #5[-] & #6[+] on figure A). For your con- - - venience jumper function is noted on the circuit board #1 on figure A. Please Note: When the unit is initially connected to the power source, you must wait for a period of approxamately 2 minutes for the sensor to stabilize. Selecting LED Indicator Operation: Jumper J1 (#3 on figure A) controls the operation of the indicator LED. If the jumper is left in place (Factory setting), the LED is active; if the jumper is removed the LED will be deactivated. For your convenience jumper function is noted on the circuit board (#1 on figure A). Setting Relay Operating Time A variable timer control (#4 on figure A) is provided so the relay points remain operative for a period adeq4ate for desired function to be completed. Turning the potentiometer clockwise will increase the duration, turning counterclockwise will reduce it. . Choosing Relay Operating Mode: The relay contact terminal strip (#7, #8, & #9 on figure A) provides easy wiring of the output contacts. Determine whether YOiJrdevice needs to . have contact made or broken to activate it. Ifyou need to break contact on a closed circuit (Such as for burglar alarm triggering etc.) connect one wire to the common contact (#8 on figure A) and the other wire to the normally closed contact (#9 on the figure A). Ifyou need to make contact on an open circuit (Such as for operating a security video event recorder etc.) then connect one wire to the common contact (#8 on figure A) and the other wire to the normally open contact (#7 on figure A). A For typical examples of relay wiring see figures B & C at right. Top View "/'''" Detection Pattern "" \ I \ I \ I \ I \ I \ I \ \ \ \ \ \ I I J I I I I I I I I I Side View D . a ITOp I .. I Backbox may ElYSSA CORP, " USA 1 IdOOEL RUGGEDONE ",ooE:1 NO: EAGO-1 POWER INPur - + RELAY OUl'1'UT 'j P~TEIITS PE.,p,'G ASSEMBlED iii CllNA NOCOMNC 1 : be rotatedto angle PIR right, left, up, or down J ~Bottoml ,Angled steel back box makes surface mounting easy and permits the installer to aim the unit more precisely Elyssa Corporation Manufacturers and Importers P.O. Box 138 Phone/Fax: (800)441 - 9122 Briarcliff Manor, NY 10510 email: elyssacorp@aol.com