lintel guide 2011 - John Nicholls Building and Plumbing Merchants
Transcription
lintel guide 2011 - John Nicholls Building and Plumbing Merchants
LINTEL GUIDE 2011 Click here to go straight to the contents page… www.stressline.ltd.uk bUiLD On OUr sTrenGTH cOmPAnY HisTOrY Stressline Limited manufactures a wide range of structural building products for domestic and commercial sectors. Stressline is the first choice for builders, contractors & specifiers across the UK because of its ability to deliver high quality products on time and at the right price, ensuring projects are not disrupted and work is completed on time. Stressline also supply direct to site or through a supply chain of merchants across the country, making sure their products are always highly accessible. Stressline’s customers choose them over other structural product manufacturers because of the promise to always be competitive on price, the mixed order delivery capabilities and the high quality service. inTrODUcinG OUr eXTenDeD LinTeL rAnGe bUiLD On OUr sTrenGTH Stressline’s in-house technical and manufacturing departments have worked hard over the last 12 months to deliver an extended range of steel lintels. The new lintel guide clearly lays out the extended standard range of steel lintels, and for the first time the prestressed concrete lintel range, allowing the customer the utmost flexibility and choice to satisfy their lintel requirements. sTrUcTUrAL bUiLDinG PrODUcTs This extended steel lintel range perfectly compliments our other structural building products. We manufacture a complete range of prestressed concrete products in addition to the prestressed concrete lintels; including flooring beams (suitable for concrete or insulation infill), hollowcore flooring, and walling panels. Precast items available include padstones, stairflights and landing slabs, although our extensive design and manufacturing resource enables special projects to be produced cost effectively. Our non structural range of products includes fencing and landscape walling products. 2 ‘h’ nominal cOnTenTs 94 94 5 - 10 cAviTY WALL: WiDe inner LeAF LinTeLs 11 - 16 cAviTY WALL: WiDe OUTer LeAF LinTeLs 17 - 22 rOLLeD sTeeL secTiOns LinTeLs 23 - 25 cLOseD eAves LinTeLs 26 - 28 Timber FrAme LinTeLs 29 - 30 sinGLe LeAF eXTernAL sOLiD WALL LinTeLs 31 - 32 inTernAL sOLiD WALL LinTeLs 33 - 34 eXTernAL sOLiD WALL LinTeLs 35 - 36 PresTresseD cOncreTe LinTeLs 37 - 39 ArcH FOrmers 40 sPeciALs 41 - 43 PADsTOnes 44 OTHer sTressLine PrODUcTs 45 TecHnicAL 46 - 47 98 213 135 cAviTY WALL: sTAnDArD LeAF LinTeLs 135 94 ‘h’ nominal 98 4 98 ‘h’ nominal 98 service DeLiverY Click on the tabs on this page to be taken through to the relevant sections 150 240 ‘h’ nominal 50 44 98 ‘h’ nominal 98 47 ‘h’ nominal 95 ‘h’ nominal 200 200 100 220 3 cOnTenTs % Service Delivery OUR COMMITMENT TO YOU SALES & SUPPORT Our Promise Our area sales managers and sales technicians are able to assist you with your specification needs. Whether advice is needed for a single lintel, or a comprehensive take off and pricing schedule for a multi dwelling development, our team is here to help. Stressline understand the day-to-day challenges you face on a building site and the importance of working with a supplier you can trust. Our promise is simple – to deliver competitively priced products, on time, to the required specification. The brochure and website outline our ranges and offer tools to assist your selection. Accreditations In addition, our unique ability to manufacture a range of structural building components offers the specifier and the buyer a complete solution for structural flooring (both beam and hollowcore), steel and concrete lintels and structural precast products, including padstones, staircases and landings. Our flexible design and manufacturing facilities enable your “special” lintel requirements to be produced quickly and efficiently. OUR PRODUCTS Our comprehensive range of standard steel and concrete lintels offers design capability for all circumstances, designed to the relevant BS EN standards and with the reassurance of BS EN ISO: 9001 (2008) management standard. The cavity lintel range is supplied with captive insulation to ensure that it is not displaced. The fabricated range is manufactured with a proven non-welded method creating a secure connection that has not compromised the galvanised protection. Our range of prestressed concrete lintels is manufactured using machinery and processes designed by our own engineers. This has enabled the maximum strength to section available, whilst producing high volumes of consistent quality products. service DELIVERY DELIVERY All our products are delivered on flat bed articulated or rigid lorries, with the option of either self offload or crane offload. Depending on the customer’s requirements both steel and concrete lintels are packaged in stock packs or in consignment loads (with the option of house plots and locations marked on the product). As we are located centrally we are able to supply all our standard products nationally, with delivery typically three to eight working days. BACK… to ‘Contents’ page 4 Stressline has an on-going commitment to improving both product and management systems; •1989: BSI Quality Assurance Accreditation to ISO 9001 • 2003: BS EN ISO 9001:2000 • 2009: ISO 9001:2008 Environmental and Sustainability We recognise our responsibilities to the environment. We are committed to developing, implementing and reviewing our management and operational policies and procedures to minimise our environmental impact. Our IMS includes all our compliance policies and achievement targets. From our ongoing environmental and sustainability commitments we have continued to achieve significant reductions in our impact as manufacturers and distributors. One major environmental benefit shared with our existing customers is the ability to source our complete range of products and for them to be delivered as a mixed load on one vehicle, instead of separate deliveries which creates wasteful and unnecessary movements. cAviTY WALL STANDARD LEAF APPLicATiOn ADvAnTAGes standard and Heavy Duty (HD) Designed to support: • Masonry loads • Masonry loads and uniformly distributed timber floor loads • Uniformly distributed roof loads (in most cases HD lintel type is required) • Easy to install and suitable for a variety of applications • Galvanised coating ensures durability/longevity • Built-in plaster key: perforated base plate to inner flange • Excellent thermal efficiency of up to 0.32 W/mK • Built-in continuous insulation extra Heavy Duty (XHD) and composite extra Heavy Duty (cXHD) Designed to support: • Concrete floor loads • Attic truss loads • Point loads for example compound trusses, steel beams etc % 0870 7503167 if in doubt please contact our technical department on ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE insTALLATiOn nOTes See page 46 for general installation notes. bAcK… to ‘Contents’ page sTAnDArD LeAF Additional requirements for composite extra Heavy Duty (cXHD) lintels • Ensure that the inner leaf channel is filled with well cured masonry before work proceeds over. Masonry needs to be built tightly against the vertical section of the channel and a mortar joint added to the top of masonry, so that the loads from units above are spread evenly over the inner flange of the lintel. • Composite lintels should be adequately propped during construction, at maximum 1.2 metre centres. Props should not be removed until the mortar has cured. 5 sTAnDArD LenGTHs (mm) sL50 100mm outer leaf 50 - 65mm cavity 100 -115mm inner leaf 98 44 98 ‘h’ nominal Lintels are available in increments of 150mm Not suitable to support precast concrete floors, attic trusses, heavy point loads. Nominal Height “h” (mm) 95 113 134 140 153 185 190 190 Weights (kg/m) 5.0 5.4 7.4 7.6 8.0 9.0 9.2 13.6 17.8 SWL 1:1/3:1 (kN) 16 17 22 23 24 28 28 28 28 SWL 19:1 (kN) 12 13 17 18 19 22 22 22 22 RM (kNm) 2.2 2.9 4.5 5.6 6.8 9.0 sTAnDArD LenGTHs (mm) sL50 HD ‘h’ nominal Lintels are available in increments of 150mm 100mm outer leaf 50 - 65mm cavity 100 -115mm inner leaf 98 44 98 Not suitable to support precast concrete floors, attic trusses, heavy point loads. 140 153 190 190 Weights (kg/m) 7.6 8.0 9.2 13.6 14.9 17.8 SWL 1:1/3:1 (kN) 42 40 41 41 33 33 SWL 19:1 (kN) 33 31 32 32 26 26 RM (kNm) 5.6 6.8 Lintels are available in increments of 150mm 150 100mm outer leaf 50 - 65mm cavity 100 -115mm inner leaf 98 44 98 Suitable to support precast concrete floors, attic trusses, and point loads. sL50 XHD 225 225 98 44 98 Suitable to support precast concrete floors, attic trusses, and point loads. sL50 cXHD 150 150 Weights (kg/m) 21.5 21.5 21.5 98 44 98 Suitable to support precast concrete floors, attic trusses, and point loads. 150 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 RM (kNm) 11.1 11.1 11.1 sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 Nominal Height “h” (mm) 225 Weights (kg/m) 26.7 26.7 26.7 26.7 225 225 225 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 RM (kNm) 20.6 20.6 20.6 20.6 sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 Lintels are available in increments of 150mm 150 100mm outer leaf 50 - 65mm cavity 100 -115mm inner leaf 600 1800 2250 1650 2100 2700 150 156 Nominal Height “h” (mm) 156 Weights (kg/m) 16.3 16.3 16.3 156 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 12.6 12.6 12.6 RM (kNm) See installation notes page 5 sTAnDArD LenGTHs (mm) sL50 cXHD 225 230 cAviTY 50 100mm outer leaf 50 - 65mm cavity 100 -115mm inner leaf Lintels are available in increments of 150mm 98 44 98 Suitable to support precast concrete floors, attic trusses, and point loads. 236 236 Nominal Height “h” (mm) 236 Weights (kg/m) 19.6 19.6 19.6 19.6 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 21.5 21.5 21.5 20.5 RM (kNm) See installation notes page 5 bAcK… to ‘Contents’ page 600 1950 3150 4050 1800 3000 3900 4800 236 6 215 215 10.0 13.3 15.5 16.2 Nominal Height “h” (mm) Lintels are available in increments of 150mm 100mm outer leaf 50 - 65mm cavity 100 -115mm inner leaf 600 1350 1650 2250 2850 4050 1200 1500 2100 2700 3900 4200 Nominal Height “h” (mm) sTAnDArD LenGTHs (mm) sL50 XHD 150 600 1350 1650 1950 2250 2550 2850 3150 4050 1200 1500 1800 2100 2400 2700 3000 3900 4800 215 10.0 13.3 16.2 600 1350 1650 1950 2250 2550 2850 3150 4050 1200 1500 1800 2100 2400 2700 3000 3900 4800 95 113 134 140 153 185 190 190 Weights (kg/m) 5.2 5.6 7.7 7.9 8.3 9.3 9.5 14.1 17.9 SWL 1:1/3:1 (kN) 16 17 22 23 24 28 28 28 28 SWL 19:1 (kN) 12 13 17 18 19 22 22 22 22 RM (kNm) 2.2 2.9 4.5 5.6 6.8 9.0 600 1350 1650 2250 2850 4050 1200 1500 2100 2700 3900 4200 Nominal Height “h” (mm) 140 153 190 190 Weights (kg/m) 7.9 8.3 9.5 14.1 14.9 17.9 SWL 1:1/3:1 (kN) 42 40 41 41 33 33 SWL 19:1 (kN) 33 31 32 32 26 26 RM (kNm) 5.6 6.8 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 207 600 1800 2250 1650 2100 2700 150 150 Weights (kg/m) 21.5 21.5 21.5 98 64 98 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL70 HD 207 10.0 13.3 15.5 16.2 Nominal Height “h” (mm) 10.0 13.3 16.2 100mm outer leaf 70 - 85mm cavity 100 -115mm inner leaf ‘h’ nominal sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 207 ‘h’ nominal Nominal Height “h” (mm) sL70 100mm outer leaf 70 - 85mm cavity 100 -115mm inner leaf 98 64 98 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL70 XHD 150 150 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 100mm outer leaf 70 - 85mm cavity 100 -115mm inner leaf 150 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 98 64 98 RM (kNm) 11.1 11.1 11.1 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 sL70 XHD 225 Nominal Height “h” (mm) 225 225 225 225 Weights (kg/m) 26.7 26.7 26.7 26.7 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 100mm outer leaf 70 - 85mm cavity 100 -115mm inner leaf 225 Lintels are available in increments of 150mm 98 64 98 RM (kNm) 20.6 20.6 20.6 20.6 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 sL70 cXHD 150 Nominal Height “h” (mm) 156 156 156 Weights (kg/m) 16.3 16.3 16.3 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 100mm outer leaf 70 - 85mm cavity 100 -115mm inner leaf 150 Lintels are available in increments of 150mm 98 64 98 12.6 12.6 12.6 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 sL70 cXHD 225 See installation notes page 5 236 236 236 236 Weights (kg/m) 19.6 19.6 19.6 19.6 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 100mm outer leaf 70 - 85mm cavity 100 -115mm inner leaf 98 64 98 Suitable to support precast concrete floors, attic trusses, and point loads. 21.5 21.5 21.5 20.5 See installation notes page 5 7 bAcK… to ‘Contents’ page cAviTY 70 Nominal Height “h” (mm) 230 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm sTAnDArD LenGTHs (mm) sL100 Lintels are available in increments of 150mm ‘h’ nominal 100mm outer leaf 100 - 110mm cavity 100 -115mm inner leaf 98 94 98 600 1350 1650 1950 2250 2550 2850 3150 4050 1200 1500 1800 2100 2400 2700 3000 3900 4800 Nominal Height “h” (mm) 95 113 134 140 153 185 190 190 225 Weights (kg/m) 5.3 5.7 7.9 8.10 8.5 9.5 9.6 14.3 19.6 SWL 1:1/3:1 (kN) 16 17 22 23 24 28 28 28 28 22 22 22 SWL 19:1 (kN) 12 13 17 18 19 22 Not suitable to support precast concrete floors, attic trusses, heavy point loads. RM (kNm) 2.2 2.9 4.5 5.6 6.8 9.0 sL100 HD sTAnDArD LenGTHs (mm) ‘h’ nominal Lintels are available in increments of 150mm 100mm outer leaf 100 - 110mm cavity 100 -115mm inner leaf 94 98 98 600 1350 1650 2250 2850 4050 1200 1500 2100 2700 3900 4200 Nominal Height “h” (mm) 140 153 190 190 225 225 Weights (kg/m) 8.1 8.5 9.6 14.3 16.1 19.6 SWL 1:1/3:1 (kN) 42 40 41 41 33 33 32 32 26 26 SWL 19:1 (kN) 33 31 Not suitable to support precast concrete floors, attic trusses, heavy point loads. RM (kNm) 5.6 6.8 sL100 XHD 150 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 150 100mm outer leaf 100 - 110mm cavity 100 -115mm inner leaf 98 94 98 10.0 13.3 15.5 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 150 150 Weights (kg/m) 22.3 22.3 22.3 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 11.1 11.1 11.1 sL100 XHD 225 sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 Lintels are available in increments of 150mm 225 100mm outer leaf 100 - 110mm cavity 100 -115mm inner leaf 98 94 98 Nominal Height “h” (mm) 225 225 225 225 Weights (kg/m) 27.6 27.6 27.6 27.6 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 20.6 20.6 20.6 20.6 sL100 cXHD 150 sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 Lintels are available in increments of 150mm 150 100mm outer leaf 100 - 110mm cavity 100 -115mm inner leaf 98 94 98 Suitable to support precast concrete floors, attic trusses, and point loads. Nominal Height “h” (mm) 156 Weights (kg/m) 17.0 17.0 17.0 156 156 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 12.6 12.6 12.6 See installation notes page 5 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 100mm outer leaf 100 - 110mm cavity 100 -115mm inner leaf 230 cAviTY 100 sL100 cXHD 225 98 94 98 Suitable to support precast concrete floors, attic trusses, and point loads. Nominal Height “h” (mm) 236 Weights (kg/m) 20.5 20.5 20.5 20.5 236 236 236 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 21.5 21.5 21.5 20.5 See installation notes page 5 bAcK… to ‘Contents’ page 600 1950 3150 4050 1800 3000 3900 4800 8 16.2 10.0 13.3 16.2 600 1350 1650 1950 2250 2550 2850 3150 4050 1200 1500 1800 2100 2400 2700 3000 3900 4800 95 113 134 153 185 185 190 Weights (kg/m) 5.6 6.0 8.2 8.8 9.8 9.8 10.0 14.8 19.7 SWL 1:1/3:1 (kN) 16 17 22 27 31 28 28 28 28 SWL 19:1 (kN) 12 13 17 21 25 22 22 22 22 RM (kNm) 2.2 2.9 4.5 6.8 9.0 9.0 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 600 1350 1650 2250 2850 4050 1200 1500 2100 2700 3900 4200 Nominal Height “h” (mm) 140 153 190 Weights (kg/m) 8.4 8.8 10.0 14.8 15.5 19.7 SWL 1:1/3:1 (kN) 42 40 41 41 33 33 SWL 19:1 (kN) 33 31 32 32 26 26 RM (kNm) 5.6 6.8 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 190 205 600 1800 2250 1650 2100 2700 150 150 Weights (kg/m) 23.3 23.3 23.3 205 10.0 13.3 16.2 100mm outer leaf 120 - 135mm cavity 100 -115mm inner leaf 98 114 98 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL120 HD 205 10.0 13.3 15.5 16.2 Nominal Height “h” (mm) 190 ‘h’ nominal Nominal Height “h” (mm) sL120 ‘h’ nominal Lintels are available in increments of 150mm 100mm outer leaf 120 - 135mm cavity 100 -115mm inner leaf 98 114 98 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL120 XHD 150 150 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 100mm outer leaf 120 - 135mm cavity 100 -115mm inner leaf 150 sTAnDArD LenGTHs (mm) 98 114 98 RM (kNm) 11.1 11.1 11.1 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 sL120 XHD 225 Nominal Height “h” (mm) 225 225 225 225 Weights (kg/m) 28.6 28.6 28.6 28.6 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 100mm outer leaf 120 - 135mm cavity 100 -115mm inner leaf 225 Lintels are available in increments of 150mm 98 114 98 RM (kNm) 20.6 20.6 20.6 20.6 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 sL120 cXHD 150 Nominal Height “h” (mm) 156 156 156 Weights (kg/m) 18.1 18.1 18.1 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 100mm outer leaf 120 - 135mm cavity 100 -115mm inner leaf 150 Lintels are available in increments of 150mm 98 114 98 12.6 12.6 12.6 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 sL120 cXHD 225 See installation notes page 5 Nominal Height “h” (mm) 236 Weights (kg/m) 21.5 21.5 21.5 21.5 236 236 236 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 100mm outer leaf 120 - 135mm cavity 100 -115mm inner leaf 98 114 98 Suitable to support precast concrete floors, attic trusses, and point loads. 21.5 21.5 21.5 20.5 See installation notes page 5 9 bAcK… to ‘Contents’ page cAviTY 120 Lintels are available in increments of 150mm 230 sTAnDArD LenGTHs (mm) sTAnDArD LenGTHs (mm) sL150 ‘h’ nominal Lintels are available in increments of 150mm 100mm outer leaf 150 - 165mm cavity 100 -115mm inner leaf 98 144 98 600 1350 1650 1950 2250 2550 2850 3150 4050 1200 1500 1800 2100 2400 2700 3000 3900 4800 Nominal Height “h” (mm) 95 113 134 153 185 Weights (kg/m) 5.8 6.3 8.5 9.0 10.0 10.0 10.2 15.2 21.2 SWL 1:1/3:1 (kN) 16 17 22 27 31 28 28 28 28 22 22 22 185 SWL 19:1 (kN) 12 13 17 21 25 22 Not suitable to support precast concrete floors, attic trusses, heavy point loads. RM (kNm) 2.2 2.9 4.5 6.8 9.0 9.0 sL150 HD sTAnDArD LenGTHs (mm) ‘h’ nominal Lintels are available in increments of 150mm 100mm outer leaf 150 - 165mm cavity 100 -115mm inner leaf 98 144 98 600 1350 1650 2250 2850 4050 1200 1500 2100 2700 3900 4200 Nominal Height “h” (mm) 140 153 190 Weights (kg/m) 8.6 9.0 10.2 15.2 16.4 21.2 SWL 1:1/3:1 (kN) 42 40 41 41 33 33 32 32 26 26 SWL 19:1 (kN) 33 31 Not suitable to support precast concrete floors, attic trusses, heavy point loads. RM (kNm) 5.6 6.8 sL150 XHD 150 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 150 100mm outer leaf 150 - 165mm cavity 100 -115mm inner leaf 98 144 98 150 Weights (kg/m) 24.9 24.9 24.9 55 43 32 SWL 19:1 (kN) 46 36 27 sL150 XHD 225 sTAnDArD LenGTHs (mm) 11.1 11.1 11.1 Lintels are available in increments of 150mm 225 98 144 98 150 SWL 5:1 (kN) RM (kNm) 100mm outer leaf 150 - 165mm cavity 100 -115mm inner leaf 600 1800 2250 1650 2100 2700 150 600 2250 2850 3450 2100 2700 3300 3900 Nominal Height “h” (mm) 225 Weights (kg/m) 30.5 30.5 30.5 30.5 225 225 225 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 20.6 20.6 20.6 20.6 sL150 cXHD 150 sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 Lintels are available in increments of 150mm 150 100mm outer leaf 150 - 165mm cavity 100 -115mm inner leaf 98 144 98 Suitable to support precast concrete floors, attic trusses, and point loads. Nominal Height “h” (mm) 156 Weights (kg/m) 19.6 19.6 19.6 156 156 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 12.6 12.6 12.6 See installation notes page 5 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 100mm outer leaf 150 - 165mm cavity 100 -115mm inner leaf 230 cAviTY 150 sL150 cXHD 225 98 144 98 Suitable to support precast concrete floors, attic trusses, and point loads. Nominal Height “h” (mm) 236 Weights (kg/m) 23.3 23.3 23.3 23.3 236 236 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 21.5 21.5 21.5 20.5 See installation notes page 5 bAcK… to ‘Contents’ page 600 1950 3150 4050 1800 3000 3900 4800 236 10 215 215 10.0 13.3 15.5 16.2 Nominal Height “h” (mm) Suitable to support precast concrete floors, attic trusses, and point loads. 190 190 190 215 10.0 13.3 16.2 cAviTY WALL WIDE INNER LEAF (WIL) APPLicATiOn ADvAnTAGes: These lintels are suitable to support a 125-150mm inner leaf of blockwork. • Easy to install and suitable for a variety of applications • Galvanised coating ensures durability/longevity • Built-in plaster key – perforated base plate to inner flange • Excellent thermal efficiency of up to 0.32 W/mK • Built-in continuous insulation standard (WiL) and Heavy Duty (HD WiL) Designed to support: • Masonry loads • Masonry loads and uniformly distributed timber floor loads • Uniformly distributed roof loads (in most cases HD lintel type is required) extra Heavy Duty (XHD WiL) and composite extra Heavy Duty (cXHD WiL) Designed to support: • Concrete floor loads • Attic truss loads • Point loads for example compound trusses, steel beams etc % 0870 7503167 if in doubt please contact our technical department on ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE insTALLATiOn nOTes See page 46 for general installation notes. bAcK… to ‘Contents’ page 11 WiDe inner LeAF (WiL) Additional requirements for composite extra Heavy Duty (cXHD WiL) • Ensure that the inner leaf channel is filled with well cured masonry before work proceeds over. Masonry needs to be built tightly against the vertical section of the channel and a mortar joint added to the top of masonry, so that the loads from units above are spread evenly over the inner flange of the lintel. • Composite lintels should be adequately propped during construction, at maximum 1.2 metre centres. Props should not be removed until the mortar has cured. sTAnDArD LenGTHs (mm) sL50 WiL sL150 Lintels are available in increments of 150mm ‘h’ nominal Nominal Height “h” (mm) 100mm outer leaf 50 - 65mm cavity 125 -150mm inner leaf 98 44 135 Not suitable to support precast concrete floors, attic trusses, heavy point loads. Weights (kg/m) ‘h’ nominal 98 44 135 113 134 31 37 28 28 SWL 19:1 (kN) 20 20 24 24 24 24 29 22 22 RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 600 1350 1650 2250 2850 4050 1200 1500 2100 2700 3900 4200 Nominal Height “h” (mm) 134 140 153 Weights (kg/m) 12.0 12.3 12.9 14.5 15.8 18.7 36 41 33 33 32 26 26 8.8 sL50 XHD 150 WiL sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 150 225 13.3 15.5 16.2 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 Weights (kg/m) 23.7 23.7 23.7 150 150 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 RM (kNm) 11.1 11.1 11.1 sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 Lintels are available in increments of 150mm Nominal Height “h” (mm) 225 225 225 225 Weights (kg/m) 28.7 28.7 28.7 28.7 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 20.6 20.6 20.6 20.6 sL50 cXHD 150 WiL sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 Lintels are available in increments of 150mm 150 100mm outer leaf 50 - 65mm cavity 125 -150mm inner leaf 98 44 135 Suitable to support precast concrete floors, attic trusses, and point loads. Nominal Height “h” (mm) 156 Weights (kg/m) 17.1 17.1 17.1 156 156 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 12.6 12.6 12.6 sTAnDArD LenGTHs (mm) 100mm outer leaf 50 - 65mm cavity 125 -150mm inner leaf Lintels are available in increments of 150mm 230 cAviTY 50 WiL See installation notes page 11 sL50 cXHD 225 WiL 98 64 135 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 Nominal Height “h” (mm) 236 Weights (kg/m) 20.5 20.5 20.5 20.5 236 236 236 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 21.5 21.5 21.5 20.5 See installation notes page 11 bAcK… to ‘Contents’ page 215 45 7.7 140 215 48 6.4 98 44 190 SWL 1:1/3:1 (kN) RM (kNm) 100mm outer leaf 50 - 65mm cavity 125 -150mm inner leaf 215 31 28 sL50 XHD 225 WiL 190 31 35 Suitable to support precast concrete floors, attic trusses, and point loads. 190 31 38 140 185 26 SWL 19:1 (kN) 98 44 153 26 Not suitable to support precast concrete floors, attic trusses, heavy point loads. 100mm outer leaf 50 - 65mm cavity 125 -150mm inner leaf 140 SWL 1:1/3:1 (kN) Lintels are available in increments of 150mm 100mm outer leaf 50 - 65mm cavity 125 -150mm inner leaf 95 10.2 11.0 12.0 12.3 12.9 14.4 14.5 14.5 18.7 sTAnDArD LenGTHs (mm) sL50 HD WiL 600 1350 1650 1950 2250 2550 2850 3150 4050 1200 1500 1800 2100 2400 2700 3000 3900 4200 12 13.3 13.3 16.2 Weights (kg/m) 95 113 134 140 153 185 190 190 207 10.6 11.5 12.4 12.7 13.3 14.8 14.9 14.9 18.7 SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28 28 SWL 19:1 (kN) 20 20 24 24 24 24 29 22 22 RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 600 1350 1650 2250 2850 4050 1200 1500 2100 2700 3900 4200 Nominal Height “h” (mm) 134 140 153 190 207 Weights (kg/m) 12.4 12.7 13.3 14.9 15.8 18.7 48 45 36 41 33 33 SWL 19:1 (kN) 38 35 28 32 26 26 RM (kNm) 6.4 7.7 8.8 Lintels are available in increments of 150mm 13.3 15.5 16.2 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 150 Weights (kg/m) 23.7 23.7 23.7 13.3 13.3 16.2 100mm outer leaf 70 - 85mm cavity 100 -150mm inner leaf 98 64 135 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL70 HD WiL 207 SWL 1:1/3:1 (kN) sTAnDArD LenGTHs (mm) sL70 WiL ‘h’ nominal Nominal Height “h” (mm) 600 1350 1650 1950 2250 2550 2850 3150 4050 1200 1500 1800 2100 2400 2700 3000 3900 4200 ‘h’ nominal Lintels are available in increments of 150mm 100mm outer leaf 70 - 85mm cavity 100 -150mm inner leaf 98 64 135 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL70 XHD 150 WiL 150 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 100mm outer leaf 70 - 85mm cavity 100 -150mm inner leaf 150 sTAnDArD LenGTHs (mm) 98 64 140 RM (kNm) 11.1 11.1 11.1 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 sL70 XHD 225 WiL Nominal Height “h” (mm) 225 225 225 225 Weights (kg/m) 28.7 28.7 28.7 28.7 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 100mm outer leaf 70 - 85mm cavity 100 -150mm inner leaf 225 Lintels are available in increments of 150mm 98 64 140 RM (kNm) 20.6 20.6 20.6 20.6 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 sL70 cXHD 150 WiL Nominal Height “h” (mm) 156 156 156 Weights (kg/m) 17.1 17.1 17.1 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 100mm outer leaf 70 - 85mm cavity 100 -150mm inner leaf 150 Lintels are available in increments of 150mm 98 64 135 600 1950 3150 4050 1800 3000 3900 4800 sL70 cXHD 225 WiL See installation notes page 11 Lintels are available in increments of 150mm Nominal Height “h” (mm) 236 Weights (kg/m) 20.5 20.5 20.5 20.5 236 236 236 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 100mm outer leaf 70 - 85mm cavity 100 - 150mm inner leaf 230 sTAnDArD LenGTHs (mm) 98 64 135 Suitable to support precast concrete floors, attic trusses, and point loads. 21.5 21.5 21.5 20.5 See installation notes page 11 13 bAcK… to ‘Contents’ page cAviTY 70 WiL 12.6 12.6 12.6 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) sL100 WiL Lintels are available in increments of 150mm ‘h’ nominal Nominal Height “h” (mm) 100mm outer leaf 100 - 110mm cavity 125 -150mm inner leaf 98 94 135 Weights (kg/m) 600 1350 1650 1950 2250 2550 2850 3150 4050 1200 1500 1800 2100 2400 2700 3000 3900 4200 95 113 134 140 153 185 26 26 31 31 31 31 37 28 28 29 22 22 20 20 24 24 24 24 RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 sL100 HD WiL sTAnDArD LenGTHs (mm) ‘h’ nominal Lintels are available in increments of 150mm 94 135 600 1350 1650 2250 2850 4050 1200 1500 2100 2700 3900 4200 Nominal Height “h” (mm) 134 140 153 Weights (kg/m) 12.7 13.0 13.6 15.2 17.0 20.5 36 41 33 33 32 26 26 35 28 RM (kNm) 6.4 7.7 8.8 sL100 XHD 150 WiL sTAnDArD LenGTHs (mm) 150 Lintels are available in increments of 150mm 140 13.3 15.5 16.2 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 150 150 Weights (kg/m) 24.4 24.4 24.4 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 11.1 11.1 11.1 sL100 XHD 225 WiL sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 Lintels are available in increments of 150mm 225 100mm outer leaf 100 - 110mm cavity 125 -150mm inner leaf 98 94 140 Nominal Height “h” (mm) 225 225 225 225 Weights (kg/m) 29.6 29.6 29.6 29.6 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 20.6 20.6 20.6 20.6 sL100 cXHD 150 WiL sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 Lintels are available in increments of 150mm 150 100mm outer leaf 100 - 110mm cavity 125 -150mm inner leaf 98 94 135 Nominal Height “h” (mm) 156 Weights (kg/m) 17.9 17.9 17.9 156 156 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 12.6 12.6 12.6 See installation notes page 11 sTAnDArD LenGTHs (mm) sL100 cXHD 225 WiL 100mm outer leaf 100 - 110mm cavity 125 -150mm inner leaf Lintels are available in increments of 150mm 230 cAviTY 100 WiL Suitable to support precast concrete floors, attic trusses, and point loads. 98 94 135 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 236 236 Nominal Height “h” (mm) 236 Weights (kg/m) 21.4 21.4 21.4 21.4 236 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 21.5 21.5 21.5 20.5 See installation notes page 11 bAcK… to ‘Contents’ page 225 45 38 94 225 48 SWL 19:1 (kN) 98 190 SWL 1:1/3:1 (kN) Not suitable to support precast concrete floors, attic trusses, heavy point loads. 100mm outer leaf 100 - 110mm cavity 125 -150mm inner leaf 225 SWL 1:1/3:1 (kN) SWL 19:1 (kN) 98 190 10.8 11.6 12.7 13.0 13.6 15.1 15.2 15.2 20.5 Not suitable to support precast concrete floors, attic trusses, heavy point loads. 100mm outer leaf 100 - 110mm cavity 125 -150mm inner leaf 190 14 13.3 13.3 16.2 113 134 140 153 185 190 190 205 11.4 12.2 13.2 13.4 14.0 15.6 15.7 15.7 20.5 SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28 28 SWL 19:1 (kN) 20 20 24 24 24 24 29 22 22 RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 600 1350 1650 2250 2850 4050 1200 1500 2100 2700 3900 4200 Nominal Height “h” (mm) 134 140 153 190 205 Weights (kg/m) 13.2 13.4 14.0 15.7 16.4 20.5 48 45 36 41 33 33 SWL 19:1 (kN) 38 35 28 32 26 26 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 6.4 7.7 8.8 13.3 15.5 16.2 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 150 Weights (kg/m) 25.5 25.5 25.5 98 114 135 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL120 HD WiL 205 SWL 1:1/3:1 (kN) RM (kNm) 13.3 13.3 16.2 100mm outer leaf 120 - 135mm cavity 125 -150mm inner leaf ‘h’ nominal Weights (kg/m) 95 sL120 WiL 100mm outer leaf 120 - 135mm cavity 125 -150mm inner leaf ‘h’ nominal Nominal Height “h” (mm) 600 1350 1650 1950 2250 2550 2850 3150 4050 1200 1500 1800 2100 2400 2700 3000 3900 4200 98 114 135 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL120 XHD 150 WiL 150 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 100mm outer leaf 120 - 135mm cavity 125 -150mm inner leaf 150 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 98 114 140 RM (kNm) 11.1 11.1 11.1 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 sL120 XHD 225 WiL Nominal Height “h” (mm) 225 225 225 225 Weights (kg/m) 30.6 30.6 30.6 30.6 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 100mm outer leaf 120 - 135mm cavity 125 -150mm inner leaf 225 Lintels are available in increments of 150mm 98 114 140 RM (kNm) 20.6 20.6 20.6 20.6 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 sL120 cXHD 150 WiL Nominal Height “h” (mm) 156 156 156 Weights (kg/m) 18.9 18.9 18.9 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 98 114 135 12.6 12.6 12.6 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 sL120 cXHD 225 WiL See installation notes page 11 Nominal Height “h” (mm) 236 236 236 236 Weights (kg/m) 22.5 22.5 22.5 22.5 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 100mm outer leaf 120 - 135mm cavity 125 -150mm inner leaf 230 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 98 114 135 Suitable to support precast concrete floors, attic trusses, and point loads. 21.5 21.5 21.5 20.5 See installation notes page 11 15 bAcK… to ‘Contents’ page cAviTY 120 WiL RM (kNm) 100mm outer leaf 120 - 135mm cavity 125 -150mm inner leaf 150 Lintels are available in increments of 150mm sTAnDArD LenGTHs (mm) sL150 WiL Lintels are available in increments of 150mm Nominal Height “h” (mm) ‘h’ nominal 100mm outer leaf 150 - 165mm cavity 125 -150mm inner leaf Weights (kg/m) 600 1350 1650 1950 2250 2550 2850 3150 4050 1200 1500 1800 2100 2400 2700 3000 3900 4200 95 113 134 140 153 185 26 26 31 31 31 31 37 28 28 29 22 22 20 20 24 24 24 24 RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 sL150 HD WiL sTAnDArD LenGTHs (mm) 135 Lintels are available in increments of 150mm ‘h’ nominal 100mm outer leaf 150 - 165mm cavity 125 -150mm inner leaf 600 1350 1650 2250 2850 4050 1200 1500 2100 2700 3900 4200 Nominal Height “h” (mm) 134 140 153 Weights (kg/m) 13.6 13.8 14.4 16.0 17.3 22.0 36 41 33 33 32 26 26 35 28 RM (kNm) 6.4 7.7 8.8 sL150 XHD 150 WiL sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 150 100mm outer leaf 150 - 165mm cavity 125 -150mm inner leaf 98 140 144 13.3 15.5 16.2 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 150 150 Weights (kg/m) 27.0 27.0 27.0 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 11.1 11.1 11.1 sL150 XHD 225 WiL sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 Lintels are available in increments of 150mm 225 100mm outer leaf 150 - 165mm cavity 125 -150mm inner leaf 98 144 Nominal Height “h” (mm) 225 Weights (kg/m) 32.5 32.5 32.5 32.5 SWL 5:1 (kN) SWL 19:1 (kN) 140 225 225 225 79 60 49 41 66 51 41 34 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 20.6 20.6 20.6 20.6 sL150 cXHD 150 WiL sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 Lintels are available in increments of 150mm 150 100mm outer leaf 150 - 165mm cavity 125 -150mm inner leaf 98 144 135 Nominal Height “h” (mm) 156 156 156 Weights (kg/m) 20.4 20.4 20.4 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 12.6 12.6 12.6 See installation notes page 11 sTAnDArD LenGTHs (mm) sL150 cXHD 225 WiL 100mm outer leaf 150 - 165mm cavity 125 -150mm inner leaf Lintels are available in increments of 150mm 230 cAviTY 150 WiL Suitable to support precast concrete floors, attic trusses, and point loads. 98 144 135 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 Nominal Height “h” (mm) 236 Weights (kg/m) 24.3 24.3 24.3 24.3 236 236 236 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 21.5 21.5 21.5 20.5 See installation notes page 11 bAcK… to ‘Contents’ page 215 45 38 135 215 48 SWL 19:1 (kN) 144 190 SWL 1:1/3:1 (kN) Not suitable to support precast concrete floors, attic trusses, heavy point loads. 98 215 SWL 1:1/3:1 (kN) SWL 19:1 (kN) 144 190 11.7 12.6 13.6 13.8 14.4 15.9 16.0 16.0 22.0 Not suitable to support precast concrete floors, attic trusses, heavy point loads. 98 190 16 13.3 13.3 16.2 cAviTY WALL WIDE OUTER LEAF (WOL) APPLicATiOn ADvAnTAGes These lintels are suitable to support a 125-150mm outer leaf of blockwork or stonework. • Easy to install and suitable for a variety of applications • Galvanised coating ensures durability/longevity • Built-in plaster key – perforated base plate to inner flange • Excellent thermal efficiency of up to 0.32 W/mK • Built-in continuous insulation standard and Heavy Duty (HD WOL) Designed to support: • Masonry loads • Masonry loads and uniformly distributed timber floor loads • Uniformly distributed roof loads (in most cases HD lintel type is required) extra Heavy Duty (XHD WOL) and composite extra Heavy Duty (cXHD WOL) Designed to support: • Concrete floor loads • Attic truss loads • Point loads for example compound trusses, steel beams etc % 0870 7503167 if in doubt please contact our technical department on ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE insTALLATiOn nOTes See page 46 for general installation notes. bAcK… to ‘Contents’ page 17 WiDe OUTer LeAF (WOL) Additional requirements for composite extra Heavy Duty (cXHD WOL) • Ensure that the inner leaf channel is filled with well cured masonry before work proceeds over. Masonry needs to be built tightly against the vertical section of the channel and a mortar joint added to the top of masonry, so that the loads from units above are spread evenly over the inner flange of the lintel. • Composite lintels should be adequately propped during construction, at maximum 1.2 metre centres. Props should not be removed until the mortar has cured. sTAnDArD LenGTHs (mm) sL50 WOL Lintels are available in increments of 150mm Nominal Height “h” (mm) ‘h’ nominal 125 -150mm outer leaf 50 - 65mm cavity 100mm inner leaf 135 44 98 Weights (kg/m) 600 1350 1650 1950 2250 2550 2850 3150 1200 1500 1800 2100 2400 2700 3000 3900 95 113 134 140 153 185 SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28 29 22 SWL 19:1 (kN) 20 20 24 24 24 24 RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 sL50 HD WOL sTAnDArD LenGTHs (mm) ‘h’ nominal Lintels are available in increments of 150mm 600 1350 1650 2250 2850 1200 1500 2100 2700 3900 Nominal Height “h” (mm) 134 140 153 Weights (kg/m) 12.0 12.3 12.9 14.5 15.8 45 36 41 33 32 26 38 35 28 RM (kNm) 6.4 7.7 8.8 sL50 XHD 150 WOL sTAnDArD LenGTHs (mm) 150 Lintels are available in increments of 150mm 135 44 98 13.3 15.5 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 Weights (kg/m) 22.4 22.4 22.4 150 150 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 11.1 11.1 11.1 sL50 XHD 225 WOL sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 Lintels are available in increments of 150mm 225 125 -150mm outer leaf 50 - 65mm cavity 100mm inner leaf 135 44 98 Nominal Height “h” (mm) 225 225 225 Weights (kg/m) 27.6 27.6 27.6 27.6 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 RM (kNm) 20.6 20.6 20.6 sL50 cXHD 150 WOL sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 150 Lintels are available in increments of 150mm 135 44 98 Nominal Height “h” (mm) 156 156 Weights (kg/m) 17.1 17.1 17.1 156 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 20.6 12.6 12.6 12.6 See installation notes page 17 sTAnDArD LenGTHs (mm) sL50 cXHD 225 WOL 125 -150mm outer leaf 50 - 65mm cavity 100mm inner leaf Lintels are available in increments of 150mm 230 cAviTY 50 WOL Suitable to support precast concrete floors, attic trusses, and point loads. 225 SWL 5:1 (kN) Suitable to support precast concrete floors, attic trusses, and point loads. 125 -150mm outer leaf 50 - 65mm cavity 100mm inner leaf 135 44 98 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 Nominal Height “h” (mm) 236 Weights (kg/m) 20.5 20.5 20.5 20.5 236 236 236 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 21.5 21.5 21.5 20.5 See installation notes page 17 bAcK… to ‘Contents’ page 215 48 SWL 19:1 (kN) 125 -150mm outer leaf 50 - 65mm cavity 100mm inner leaf 190 SWL 1:1/3:1 (kN) Not suitable to support precast concrete floors, attic trusses, heavy point loads. 135 44 98 190 10.2 11.0 12.0 12.3 12.9 14.4 14.5 14.5 Not suitable to support precast concrete floors, attic trusses, heavy point loads. 125 -150mm outer leaf 50 - 65mm cavity 100mm inner leaf 190 18 13.3 13.3 Weights (kg/m) 95 113 134 140 153 185 190 190 10.6 11.5 12.4 12.7 13.3 14.8 14.9 14.9 SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28 SWL 19:1 (kN) 20 20 24 24 24 24 29 22 RM (kNm) sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 3.5 4.5 6.4 7.7 8.8 600 1350 1650 2250 2850 1200 1500 2100 2700 3900 Nominal Height “h” (mm) 134 140 153 190 Weights (kg/m) 12.4 12.7 13.3 14.9 15.8 48 45 36 41 33 SWL 19:1 (kN) 38 35 28 32 26 RM (kNm) 6.4 7.7 8.8 Lintels are available in increments of 150mm 13.3 15.5 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 150 Weights (kg/m) 22.4 22.4 22.4 13.3 13.3 125 - 150mm outer leaf 70 - 85mm cavity 100mm inner leaf 135 64 98 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL70 HD WOL 207 SWL 1:1/3:1 (kN) sTAnDArD LenGTHs (mm) 9.9 sL70 WOL ‘h’ nominal Nominal Height “h” (mm) 600 1350 1650 1950 2250 2550 2850 3150 1200 1500 1800 2100 2400 2700 3000 3900 ‘h’ nominal Lintels are available in increments of 150mm 125 - 150mm outer leaf 70 - 85mm cavity 100mm inner leaf 135 64 98 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL70 XHD 150 WOL 150 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 125 - 150mm outer leaf 70 - 85mm cavity 100mm inner leaf 150 sTAnDArD LenGTHs (mm) 135 64 98 RM (kNm) 11.1 11.1 11.1 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 sL70 XHD 225 WOL Nominal Height “h” (mm) 225 225 225 225 Weights (kg/m) 27.6 27.6 27.6 27.6 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 125 - 150mm outer leaf 70 - 85mm cavity 100mm inner leaf 225 Lintels are available in increments of 150mm 135 64 98 RM (kNm) 20.6 20.6 20.6 20.6 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 sL70 cXHD 150 WOL Nominal Height “h” (mm) 156 156 156 Weights (kg/m) 17.1 17.1 17.1 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 135 64 98 12.6 12.6 12.6 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 sL70 cXHD 225 WOL See installation notes page 17 Lintels are available in increments of 150mm Nominal Height “h” (mm) 236 236 236 236 Weights (kg/m) 20.5 20.5 20.5 20.5 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 125 - 150mm outer leaf 70 - 85mm cavity 100mm inner leaf 230 sTAnDArD LenGTHs (mm) 135 64 98 Suitable to support precast concrete floors, attic trusses, and point loads. 21.5 21.5 21.5 20.5 See installation notes page 17 19 bAcK… to ‘Contents’ page cAviTY 70 WOL RM (kNm) 125 - 150mm outer leaf 70 - 85mm cavity 100mm inner leaf 150 Lintels are available in increments of 150mm sTAnDArD LenGTHs (mm) sL100 WOL Lintels are available in increments of 150mm Nominal Height “h” (mm) ‘h’ nominal 125 - 150mm outer leaf 100 - 110mm cavity 100mm inner leaf 135 94 98 600 1350 1650 1950 2250 2550 2850 3150 1200 1500 1800 2100 2400 2700 3000 3900 95 113 134 140 153 185 SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28 29 22 SWL 19:1 (kN) 20 20 24 24 24 24 RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 sL100 HD WOL sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm ‘h’ nominal 135 94 98 600 1350 1650 2250 2850 1200 1500 2100 2700 3900 140 153 Weights (kg/m) 12.7 13.0 13.6 15.2 17.0 SWL 1:1/3:1 (kN) 48 45 36 41 33 32 26 38 35 28 RM (kNm) 6.4 7.7 8.8 sL100 XHD 150 WOL sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 150 94 98 13.3 15.5 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 150 150 Weights (kg/m) 23.2 23.2 23.2 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 11.1 11.1 11.1 sL100 XHD 225 WOL sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 Lintels are available in increments of 150mm 225 125 - 150mm outer leaf 100 - 110mm cavity 100mm inner leaf 135 94 98 Nominal Height “h” (mm) 225 225 225 225 Weights (kg/m) 28.4 28.4 28.4 28.4 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 20.6 20.6 20.6 20.6 sL100 cXHD 150 WOL sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 Lintels are available in increments of 150mm 150 125 - 150mm outer leaf 100 - 110mm cavity 100mm inner leaf 135 94 98 156 156 Nominal Height “h” (mm) 156 Weights (kg/m) 17.9 17.9 17.9 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 12.6 12.6 12.6 See installation notes page 17 sTAnDArD LenGTHs (mm) sL100 cXHD 225 WOL 125 - 150mm outer leaf 100 - 110mm cavity 100mm inner leaf Lintels are available in increments of 150mm 230 cAviTY 100 WOL Suitable to support precast concrete floors, attic trusses, and point loads. 135 94 98 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 236 236 236 Nominal Height “h” (mm) 236 Weights (kg/m) 21.2 21.2 21.2 21.2 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 21.5 21.5 21.5 20.5 See installation notes page 17 bAcK… to ‘Contents’ page 225 134 SWL 19:1 (kN) 135 190 Nominal Height “h” (mm) Not suitable to support precast concrete floors, attic trusses, heavy point loads. 125 - 150mm outer leaf 100 - 110mm cavity 100mm inner leaf 190 10.8 11.6 12.7 13.0 13.6 15.1 15.2 15.2 Weights (kg/m) Not suitable to support precast concrete floors, attic trusses, heavy point loads. 125 - 150mm outer leaf 100 - 110mm cavity 100mm inner leaf 190 20 13.3 13.3 Weights (kg/m) 95 113 134 140 153 185 190 190 11.4 12.2 13.2 13.4 14.0 15.6 15.7 15.7 SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28 SWL 19:1 (kN) 20 20 24 24 24 24 29 22 RM (kNm) sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 3.5 4.5 6.4 7.7 8.8 600 1350 1650 2250 2850 1200 1500 2100 2700 3900 Nominal Height “h” (mm) 134 Weights (kg/m) 13.2 13.4 14.0 15.7 16.4 140 153 190 48 45 36 41 33 SWL 19:1 (kN) 38 35 28 32 26 sTAnDArD LenGTHs (mm) Lintels are available in increments of 150mm 6.4 7.7 8.8 13.3 15.5 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 150 Weights (kg/m) 24.6 24.6 24.6 13.3 13.3 125 - 150mm outer leaf 120 - 135mm cavity 100mm inner leaf 135 114 98 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL120 HD WOL 205 SWL 1:1/3:1 (kN) RM (kNm) 9.9 sL120 WOL ‘h’ nominal Nominal Height “h” (mm) 600 1350 1650 1950 2250 2550 2850 3150 1200 1500 1800 2100 2400 2700 3000 3900 125 - 150mm outer leaf 120 - 135mm cavity 100mm inner leaf ‘h’ nominal Lintels are available in increments of 150mm 135 114 98 Not suitable to support precast concrete floors, attic trusses, heavy point loads. sL120 XHD 150 WOL 150 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 125 - 150mm outer leaf 120 - 135mm cavity 100mm inner leaf 150 sTAnDArD LenGTHs (mm) 135 114 98 RM (kNm) 11.1 11.1 11.1 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 sL120 XHD 225 WOL Nominal Height “h” (mm) 225 Weights (kg/m) 29.6 29.6 29.6 29.6 225 225 225 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 125 - 150mm outer leaf 120 - 135mm cavity 100mm inner leaf 225 Lintels are available in increments of 150mm 135 114 98 RM (kNm) 20.6 20.6 20.6 20.6 Suitable to support precast concrete floors, attic trusses, and point loads. sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 sL120 cXHD 150 WOL Nominal Height “h” (mm) 156 156 156 Weights (kg/m) 19.3 19.3 19.3 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 135 114 98 12.6 12.6 12.6 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 sL120 cXHD 225 WOL See installation notes page 17 Lintels are available in increments of 150mm Nominal Height “h” (mm) 236 Weights (kg/m) 22.4 22.4 22.4 22.4 236 236 236 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 125 - 150mm outer leaf 120 - 135mm cavity 100mm inner leaf 230 sTAnDArD LenGTHs (mm) 135 114 98 Suitable to support precast concrete floors, attic trusses, and point loads. 21.5 21.5 21.5 20.5 See installation notes page 17 21 bAcK… to ‘Contents’ page cAviTY 120 WOL SWL 5:1 (kN) 125 - 150mm outer leaf 120 - 135mm cavity 100mm inner leaf 150 Lintels are available in increments of 150mm sTAnDArD LenGTHs (mm) sL150 WOL Lintels are available in increments of 150mm Nominal Height “h” (mm) ‘h’ nominal 125 - 150mm outer leaf 150 - 165mm cavity 100mm inner leaf Weights (kg/m) 600 1350 1650 1950 2250 2550 2850 3150 1200 1500 1800 2100 2400 2700 3000 3900 95 113 134 140 153 185 SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28 29 22 SWL 19:1 (kN) 20 20 24 24 24 24 RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 sL150 HD WOL sTAnDArD LenGTHs (mm) 144 98 Lintels are available in increments of 150mm ‘h’ nominal 125 - 150mm outer leaf 150 - 165mm cavity 100mm inner leaf 600 1350 1650 2250 2850 1200 1500 2100 2700 3900 Nominal Height “h” (mm) 134 140 153 Weights (kg/m) 13.6 13.8 14.4 16.0 17.3 45 36 41 33 32 26 38 35 28 RM (kNm) 6.4 7.7 8.8 sL150 XHD 150 WOL sTAnDArD LenGTHs (mm) 98 Lintels are available in increments of 150mm 150 125 - 150mm outer leaf 150 - 165mm cavity 100mm inner leaf 135 144 98 13.3 15.5 600 1800 2250 1650 2100 2700 Nominal Height “h” (mm) 150 150 150 Weights (kg/m) 25.7 25.7 25.7 SWL 5:1 (kN) 55 43 32 SWL 19:1 (kN) 46 36 27 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 11.1 11.1 11.1 sL150 XHD 225 WOL sTAnDArD LenGTHs (mm) 600 2250 2850 3450 2100 2700 3300 3900 Lintels are available in increments of 150mm 225 125 - 150mm outer leaf 150 - 165mm cavity 100mm inner leaf 135 144 98 Nominal Height “h” (mm) 225 225 225 225 Weights (kg/m) 31.3 31.3 31.3 31.3 SWL 5:1 (kN) 79 60 49 41 SWL 19:1 (kN) 66 51 41 34 Suitable to support precast concrete floors, attic trusses, and point loads. RM (kNm) 20.6 20.6 20.6 20.6 sL150 cXHD 150 WOL sTAnDArD LenGTHs (mm) 600 1950 2250 1800 2100 2400 Lintels are available in increments of 150mm 150 125 - 150mm outer leaf 150 - 165mm cavity 100mm inner leaf 144 98 Suitable to support precast concrete floors, attic trusses, and point loads. Nominal Height “h” (mm) 156 156 156 Weights (kg/m) 20.5 20.5 20.5 SWL 5:1 (kN) 72 62 53 SWL 19:1 (kN) 61 52 45 RM (kNm) 12.6 12.6 12.6 See installation notes page 17 sTAnDArD LenGTHs (mm) sL150 cXHD 225 WOL 125 - 150mm outer leaf 150 - 165mm cavity 100mm inner leaf Lintels are available in increments of 150mm 230 cAviTY 150 WOL 135 135 144 98 Suitable to support precast concrete floors, attic trusses, and point loads. 600 1950 3150 4050 1800 3000 3900 4800 Nominal Height “h” (mm) 236 Weights (kg/m) 24.1 24.1 24.1 24.1 236 236 236 SWL 5:1 (kN) 89 71 55 37 SWL 19:1 (kN) 75 60 46 35 RM (kNm) 21.5 21.5 21.5 20.5 See installation notes page 17 bAcK… to ‘Contents’ page 215 48 SWL 19:1 (kN) 144 190 SWL 1:1/3:1 (kN) Not suitable to support precast concrete floors, attic trusses, heavy point loads. 135 190 11.7 12.6 13.6 13.8 14.4 15.9 16.0 16.0 Not suitable to support precast concrete floors, attic trusses, heavy point loads. 135 190 22 13.3 13.3 rOLLeD sTeeL secTiOns APPLicATiOn mATeriAL Rolled Steel (RS) and Rolled Steel Channel (RSC) fabricated lintels are designed for extreme loading conditions: • Masonry loads • Concrete floor loads • Attic truss loads • Point loads for example compound trusses, steel beams etc Lintels are manufactured using 203x133x30kg/m UB or 230x90x32.2kg/m RSC with a 6mm welded bottom plate to BS EN 10025 – 2: 2004 of steel grade S275. ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE insTALLATiOn nOTes See page 46 for general installation notes. FinisHinG Lintels are coated as standard in a red-oxide paint. However, they can be supplied, at extra cost, with a galvanised finish. ADvAnTAGes • Available in 50mm increments with a maximum length of 6600mm • Can suit a variety of cavity wall constructions • Availability 7-8 working days (red oxide finish) Additional requirements for rs and rsc type lintels • Lintels must be laterally restrained and adequately propped during construction at maximum 1.2 metre centres. Props should not be removed until the mortar has cured. • Minimum of 200mm bearing is required • RSC type lintels - channel MUST be filled with masonry before the work proceeds over and needs to be built tightly against the vertical section of the channel using good quality, well bonded mortar joints. rOLLeD sTeeL secTiOns % 0870 7503167 if in doubt please contact our technical department on bAcK… to ‘Contents’ page 23 sTAnDArD LenGTHs (mm) sL50/rs 213 Lintels are available in increments of 50mm Nominal Height “h” (mm) 213 Weights (kg/m) 41.6 41.6 41.6 41.6 41.6 41.6 41.6 SWL 5:1/19:1 (kN) RM (kNm) 240 900 5100 5400 5700 6000 6300 6600 4800 82 213 77 213 72 213 67 213 64 213 60 213 58 50.0 50.0 50.0 50.0 50.0 50.0 50.0 See installation notes page 23 100mm outer leaf 50 - 65mm cavity 100 -115mm inner leaf sTAnDArD LenGTHs (mm) sL70/rs 213 Lintels are available in increments of 50mm Nominal Height “h” (mm) 213 Weights (kg/m) 42.9 42.9 42.9 42.9 42.9 42.9 42.9 SWL 5:1/19:1 (kN) RM (kNm) 265 900 5100 5400 5700 6000 6300 6600 4800 82 213 77 213 72 213 67 213 64 213 60 213 58 50.0 50.0 50.0 50.0 50.0 50.0 50.0 See installation notes page 23 100mm outer leaf 70 - 85mm cavity 100 -115mm inner leaf sTAnDArD LenGTHs (mm) sL100/rs 213 Lintels are available in increments of 50mm Nominal Height “h” (mm) 213 Weights (kg/m) 44.6 44.6 44.6 44.6 44.6 44.6 44.6 SWL 5:1/19:1 (kN) RM (kNm) 300 900 5100 5400 5700 6000 6300 6600 4800 82 213 77 213 72 213 67 213 64 213 60 213 58 50.0 50.0 50.0 50.0 50.0 50.0 50.0 See installation notes page 23 100mm outer leaf 100 - 110mm cavity 100 -115mm inner leaf sTAnDArD LenGTHs (mm) sL120/rs 213 Lintels are available in increments of 50mm Nominal Height “h” (mm) 213 Weights (kg/m) 45.6 45.6 45.6 45.6 45.6 45.6 45.6 SWL 5:1/19:1 (kN) RM (kNm) 320 900 5100 5400 5700 6000 6300 6600 4800 82 213 77 213 72 213 67 213 64 213 60 213 58 50.0 50.0 50.0 50.0 50.0 50.0 50.0 See installation notes page 23 100mm outer leaf 120 - 135mm cavity 100 -115mm inner leaf Lintels are available in increments of 50mm 213 rOLLeD sTeeL secTiOns . sTAnDArD LenGTHs (mm) sL150/rs 350 100mm outer leaf 150 - 165mm cavity 100 -115mm inner leaf bAcK… to ‘Contents’ page 900 5100 5400 5700 6000 6300 6600 4800 Nominal Height “h” (mm) 213 Weights (kg/m) 47.1 47.1 47.1 47.1 47.1 47.1 47.1 SWL 5:1/19:1 (kN) RM (kNm) 82 213 77 213 72 213 67 213 64 213 60 213 58 50.0 50.0 50.0 50.0 50.0 50.0 50.0 See installation notes page 23 24 900 5100 5400 5700 6000 6300 6600 4800 236 Weights (kg/m) 44.1 44.1 44.1 44.1 44.1 44.1 44.1 90 85 236 80 236 76 236 72 236 69 55.7 55.7 55.7 55.7 55.7 55.7 55.7 See installation notes page 23 sTAnDArD LenGTHs (mm) Lintels are available in increments of 50mm 900 5100 5400 5700 6000 6300 6600 4800 Nominal Height “h” (mm) 236 Weights (kg/m) 45.4 45.4 45.4 45.4 45.4 45.4 45.4 SWL 5:1/19:1 (kN) RM (kNm) 95 236 90 236 85 236 80 236 76 236 72 Lintels are available in increments of 50mm 69 55.7 55.7 55.7 55.7 55.7 55.7 55.7 900 5100 5400 5700 6000 6300 6600 4800 236 Weights (kg/m) 46.6 44.6 44.6 44.6 44.6 44.6 44.6 RM (kNm) 95 236 90 236 85 236 80 236 76 236 72 Lintels are available in increments of 50mm 69 55.7 55.7 55.7 55.7 55.7 55.7 55.7 900 5100 5400 5700 6000 6300 6600 4800 236 Weights (kg/m) 47.6 47.6 47.6 47.6 47.6 47.6 47.6 RM (kNm) 95 236 90 236 85 236 80 236 76 236 72 69 55.7 55.7 55.7 55.7 55.7 55.7 55.7 900 5100 5400 5700 6000 6300 6600 4800 Nominal Height “h” (mm) 236 Weights (kg/m) 49.1 49.1 49.1 49.1 49.1 49.1 49.1 SWL 5:1/19:1 (kN) RM (kNm) 315 100mm outer leaf 120 - 135mm cavity 100 -115mm inner leaf 95 236 90 236 85 236 80 236 76 236 72 236 69 55.7 55.7 55.7 55.7 55.7 55.7 55.7 See installation notes page 23 sL150/rsc 345 100mm outer leaf 150 - 165mm cavity 100 -115mm inner leaf 25 bAcK… to ‘Contents’ page rOLLeD sTeeL secTiOns Lintels are available in increments of 50mm sL120/rsc 236 See installation notes page 23 sTAnDArD LenGTHs (mm) 295 100mm outer leaf 100 - 110mm cavity 100 -115mm inner leaf Nominal Height “h” (mm) SWL 5:1/19:1 (kN) sL100/rsc 236 See installation notes page 23 sTAnDArD LenGTHs (mm) 265 100mm outer leaf 70 - 85mm cavity 100 -115mm inner leaf Nominal Height “h” (mm) SWL 5:1/19:1 (kN) sL70/rsc 236 See installation notes page 23 sTAnDArD LenGTHs (mm) 240 100mm outer leaf 50 - 65mm cavity 100 -115mm inner leaf 230 RM (kNm) 95 236 230 SWL 5:1/19:1 (kN) 236 230 Nominal Height “h” (mm) sL50/rsc 230 Lintels are available in increments of 50mm 230 sTAnDArD LenGTHs (mm) cLOseD eAves APPLicATiOn ADvAnTAGes Open back Lintel (e) Designed to support: • Standard truss roof loads • Available in 150mm increments • The curtain brackets on Open Back Eaves Lintels can be easily fixed without the need of timber battens • Loads on Eaves HD type lintels can be applied directly to the box section, without the aid of another course of blockwork • Can suit a variety of cavity wall constructions • Built-in plaster key – perforated base plate to inner flange • Excellent thermal efficiency provided by the continuous insulation • Lintels suitable for wider cavities are available on request Heavy Duty box section Lintel (e HD and e XHD) Designed to support: • Attic trusses • Compound trusses ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE insTALLATiOn nOTes See page 46 for general installation notes. Open Back Eaves Lintels must be built in with a course of blockwork positioned tightly against the up-stand of the lintel and a continuous timber wall plate as shown in the illustration. % 0870 7503167 if in doubt please contact our technical department on cLOseD eAves bAcK… to ‘Contents’ page 26 Lintels are available in increments of 150mm 600 1650 1950 2250 2550 1500 1800 2100 2400 2700 Nominal Height “h” (mm) 150 150 150 150 Weights (kg/m) 7.2 7.2 10.7 10.7 10.7 SWL (kN) 21 18 20 17 15 RM (kNm) 3.6 3.6 4.8 4.8 4.8 sL50/e 150 150 sTAnDArD LenGTHs (mm) 50 44 98 50 - 80mm cavity 100 -115mm inner leaf Lintels are available in increments of 150mm 600 1650 1950 2250 2550 1500 1800 2100 2400 2700 Nominal Height “h” (mm) 150 150 150 150 150 Weights (kg/m) 9.9 9.9 9.9 9.9 9.9 SWL (kN) 46 38 32 28 24 RM (kNm) 7.8 7.8 7.8 7.8 7.8 sL50/e HD 150 sTAnDArD LenGTHs (mm) 104 96 50 - 80mm cavity 100 -115mm inner leaf Lintels are available in increments of 150mm 600 1650 1950 2250 2550 2850 1500 1800 2100 2400 2700 3000 Nominal Height “h” (mm) 150 150 150 150 150 Weights (kg/m) 14.8 14.8 14.8 14.8 14.8 14.8 sL50/e XHD 150 SWL (kN) 54 45 38 33 29 26 RM (kNm) 9.2 9.2 9.2 9.2 9.2 9.2 150 sTAnDArD LenGTHs (mm) 104 96 50 - 80mm cavity 100 -115mm inner leaf Lintels are available in increments of 150mm 600 1650 1950 2250 2550 1500 1800 2100 2400 2700 Nominal Height “h” (mm) 150 150 150 150 Weights (kg/m) 7.8 7.8 11.6 11.6 11.6 SWL (kN) 21 18 20 17 15 RM (kNm) 3.6 3.6 4.8 4.8 4.8 sL50/e WiL 150 150 sTAnDArD LenGTHs (mm) 50 44 135 50 - 80mm cavity 125 -150 inner leaf Lintels are available in increments of 150mm 600 1650 1950 2250 2550 1500 1800 2100 2400 2700 Nominal Height “h” (mm) 150 150 150 150 Weights (kg/m) 10.7 10.7 10.7 10.7 10.7 sL50/e HD WiL 150 46 38 32 28 24 RM (kNm) 7.8 7.8 7.8 7.8 7.8 104 125 50 - 80mm cavity 125 -150 inner leaf Lintels are available in increments of 150mm 600 1650 1950 2250 2550 2850 1500 1800 2100 2400 2700 3000 Nominal Height “h” (mm) 150 150 150 150 150 Weights (kg/m) 16.2 16.2 16.2 16.2 16.2 16.2 sL50/e XHD WiL 150 SWL (kN) 54 45 38 33 29 26 RM (kNm) 9.2 9.2 9.2 9.2 9.2 9.2 150 sTAnDArD LenGTHs (mm) 104 125 50 - 80mm cavity 125 -150 inner leaf 27 bAcK… to ‘Contents’ page cLOseD eAves 50 SWL (kN) 150 sTAnDArD LenGTHs (mm) sTAnDArD LenGTHs (mm) sL100/e 150 Lintels are available in increments of 150mm 50 84 98 600 1650 1950 2250 2550 1500 1800 2100 2400 2700 Nominal Height “h” (mm) 150 150 150 150 150 Weights (kg/m) 7.5 7.5 11.1 11.1 11.1 SWL (kN) 21 18 20 17 15 RM (kNm) 3.6 3.6 4.8 4.8 4.8 90 - 120mm cavity 100 -115mm inner leaf sTAnDArD LenGTHs (mm) sL100/e HD 150 Lintels are available in increments of 150mm 138 96 600 1650 1950 2250 2550 1500 1800 2100 2400 2700 Nominal Height “h” (mm) 150 150 150 150 150 Weights (kg/m) 10.5 10.5 10.5 10.5 10.5 SWL (kN) 46 38 32 28 24 RM (kNm) 7.8 7.8 7.8 7.8 7.8 90 - 120mm cavity 100 -115mm inner leaf sTAnDArD LenGTHs (mm) sL100/e XHD 150 Lintels are available in increments of 150mm 138 96 600 1650 1950 2250 2550 2850 1500 1800 2100 2400 2700 3000 Nominal Height “h” (mm) 150 150 150 150 150 150 Weights (kg/m) 15.6 15.6 15.6 15.6 15.6 15.6 SWL (kN) 54 45 38 33 29 26 RM (kNm) 9.2 9.2 9.2 9.2 9.2 9.2 sTAnDArD LenGTHs (mm) 600 1650 1950 2250 2550 1500 1800 2100 2400 2700 90 - 120mm cavity 100 -115mm inner leaf sL100/e WiL 150 Lintels are available in increments of 150mm 50 84 135 Nominal Height “h” (mm) 150 150 150 150 150 Weights (kg/m) 8.1 8.1 12.0 12.0 12.0 SWL (kN) 21 18 20 17 15 RM (kNm) 3.6 3.6 4.8 4.8 4.8 90 - 120mm cavity 125 -150 inner leaf sTAnDArD LenGTHs (mm) sL100/e HD WiL 138 125 600 1650 1950 2250 2550 1500 1800 2100 2400 2700 Nominal Height “h” (mm) 150 150 150 150 150 Weights (kg/m) 11.3 11.3 11.3 11.3 11.3 SWL (kN) 46 38 32 28 24 RM (kNm) 7.8 7.8 7.8 7.8 7.8 90 - 120mm cavity 125 -150 inner leaf sTAnDArD LenGTHs (mm) sL100/e XHD WiL Lintels are available in increments of 150mm 150 cLOseD eAves 100 150 Lintels are available in increments of 150mm 138 125 Nominal Height “h” (mm) 150 Weights (kg/m) 17.0 17.0 17.0 17.0 17.0 17.0 150 150 150 150 150 SWL (kN) 54 45 38 33 29 26 RM (kNm) 9.2 9.2 9.2 9.2 9.2 9.2 90 - 120mm cavity 125 -150 inner leaf bAcK… to ‘Contents’ page 600 1650 1950 2250 2550 2850 1500 1800 2100 2400 2700 3000 28 Timber FrAme APPLicATiOn ADvAnTAGes Timber Frame Lintels (TF) are designed for use in timber frame construction and are intended to support the outer leaf of masonry only, generally brickwork. • Easy to install and suitable for a variety of cavity walls • Galvanised coating ensures durability/longevity • Supplied with appropriate number of restraining clips ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE insTALLATiOn nOTes See page 46 for general installation notes. % 0870 7503167 if in doubt please contact our technical department on Additional requirements for (TF) type lintels • To avoid excessive deflection and possible twisting, lintels should be secured laterally with restraining clips and should be adequately propped during construction at maximum 1.2 meter centres. Props can be removed after the mortar has cured. • A tight fitting timber batten (supplied by others) should be placed at mid span to help prevent any lateral deflection. • Restraining clips to be spaced at maximum 500mm centres, starting from mid span. Clips must be nailed to the timber frame. Timber FrAme bAcK… to ‘Contents’ page 29 sTAnDArD LenGTHs (mm) sL50 TF ‘h’ nominal Lintels are available in increments of 150mm 98 47 Nominal Height “h” (mm) 125 122 135 185 190 215 Weights (kg/m) 3.8 5.6 6.0 7.2 7.3 7.9 SWL (kN) 9 9 9 11 11 13 RM (kNm) 1.2 1.9 2.6 4.0 4.8 6.2 See installation notes page 29 50 - 65mm cavity 102mm outer leaf sTAnDArD LenGTHs (mm) sL70 TF ‘h’ nominal Lintels are available in increments of 150mm 98 67 Nominal Height “h” (mm) 130 141 161 185 200 215 Weights (kg/m) 4.1 4.3 7.1 7.6 7.8 8.1 SWL (kN) 9 9 9 11 11 13 RM (kNm) 1.2 1.6 2.6 4.0 4.8 6.2 sTAnDArD LenGTHs (mm) sL100 TF Lintels are available in increments of 150mm ‘h’ nominal 90 - 100mm cavity 102mm outer leaf 600 1350 1650 2550 3150 3750 1200 1500 2400 3000 3600 3900 See installation notes page 29 70 - 80mm cavity 102mm outer leaf 98 600 1350 1950 2550 3150 3750 1200 1800 2400 3000 3600 3900 97 Nominal Height “h” (mm) 146 157 174 220 245 280 Weights (kg/m) 4.8 7.5 7.9 9.0 9.7 10.5 SWL (kN) 9 9 9 11 11 13 RM (kNm) 1.2 1.9 2.6 4.0 4.8 6.2 See installation notes page 29 Timber FrAme bAcK… to ‘Contents’ page 600 1350 1950 2550 3150 3750 1200 1800 2400 3000 3600 3900 30 sinGLe LeAF eXTernAL sOLiD WALL APPLicATiOn ADvAnTAGes Tray (Tr) and channel (cH) Designed to support: • 100mm external leaf solid blockwork • 102mm external leaf brickwork • 140mm external leaf solid blockwork (TR WL and/or CH WL) • Easy to install • Suitable for faced brick/block walls • Suitable for use over meter boxes and garage personnel doors • Galvanised coating ensures durability/longevity ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE insTALLATiOn nOTes % 0870 7503167 if in doubt please contact our technical department on See page 46 for general installation notes. bAcK… to ‘Contents’ page 31 sinGLe LeAF eXTernAL sOLiD WALL Additional requirements for (Tr) and (cH) type lintels • To avoid excessive deflection and possible twisting, lintels should be adequately propped during construction at maximum 1.2 metre centres. Props can be removed after the mortar has cured. • To achieve stated loading figures, Channel Lintels (CH) MUST be filled with well cured masonry before work proceeds over. STANDARD LENGTHS (mm) SL100 TR ‘h’ nominal Lintels are available in increments of 150mm 95 600 1650 1950 2550 3150 1500 1800 2400 3000 3900 Nominal Height “h” (mm) 115 115 165 225 225 Weights (kg/m) 5.0 5.0 6.8 8.9 8.9 SWL (kN) 5 6 10 17 13 RM (kNm) 1.4 1.4 3.6 5.8 5.8 See installation notes page 31 STANDARD LENGTHS (mm) SL100 CH 150 156 Lintels are available in increments of 150mm 100 600 1650 1950 1500 1800 2100 Nominal Height “h” (mm) 156 156 156 Weights (kg/m) 7.0 7.0 7.0 SWL (kN) 29 23 20 RM (kNm) 4.9 4.9 4.9 See installation notes page 31 STANDARD LENGTHS (mm) SL100 CH 225 231 Lintels are available in increments of 150mm 100 Nominal Height “h” (mm) 231 231 231 231 231 Weights (kg/m) 8.8 8.8 8.8 8.8 8.8 SWL (kN) 57 47 34 30 20 RM (kNm) 9.8 9.8 9.8 9.8 9.8 See installation notes page 31 SINGLE LEAF EXTERNAL SOLID WALL BACK… to ‘Contents’ page 600 1650 1950 2550 3150 1500 1800 2400 3000 3900 32 inTernAL sOLiD WALL APPLicATiOn ADvAnTAGes Galvanised steel box lintels are designed for use in internal 100mm wide or 140-150mm wide, nonload bearing and load bearing walls. Designed to support: • Concrete floor loads • Masonry loads, timber floor joists and/or roof trusses • Attic truss loads • Point loads for example compound trusses, steel beams etc • Easy to install • Suitable for 100mm wide or 140-150mm wide walls • Can be supplied insulated for use at eaves level • Galvanised coating ensures durability/longevity • Built-in plaster key – perforated plate to base and two sides • Suitable for use under various loading conditions ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE insTALLATiOn nOTes % 0870 7503167 if in doubt please contact our technical department on See page 46 for general installation notes. inTernAL sOLiD WALL bAcK… to ‘Contents’ page 33 sTAnDArD LenGTHs (mm) sL100 bOX 100 ‘h’ nominal Lintels are available in increments of 150mm 600 1650 1950 2550 2850 3750 4350 1500 1800 2400 2700 3600 4200 4800 Nominal Height “h” (mm) 108 108 150 150 225 Weights (kg/m) 6.9 6.9 8.3 8.3 15.9 15.9 15.9 SWL (kN) 24 20 28 24 RM (kNm) 4.1 4.1 7.8 7.8 35 225 225 30 27 15.5 15.5 15.5 Standard Duty sTAnDArD LenGTHs (mm) sL100 bOX HD ‘h’ nominal Lintels are available in increments of 150mm 100 600 1350 1950 1200 1800 2700 Nominal Height “h” (mm) 150 225 Weights (kg/m) 8.3 15.9 15.9 SWL (kN) 51 RM (kNm) 7.8 75 225 49 15.5 15.5 Heavy Duty sTAnDArD LenGTHs (mm) sL140 bOX ‘h’ nominal Lintels are available in increments of 150mm 140 600 1650 2250 2550 2850 3750 4350 1500 2100 2400 2700 3600 4200 4800 Nominal Height “h” (mm) 150 150 150 150 225 Weights (kg/m) 9.7 9.7 9.7 9.7 18.0 18.0 18.0 SWL (kN) 50 35 30 26 RM (kNm) 8.6 8.6 8.6 8.6 40 sTAnDArD LenGTHs (mm) ‘h’ nominal Lintels are available in increments of 150mm 140 600 1350 1950 1200 1800 2700 Nominal Height “h” (mm) 150 225 Weights (kg/m) 9.7 18.0 18.0 SWL (kN) 60 RM (kNm) 8.6 sTAnDArD LenGTHs (mm) 900 1050 1200 80 225 54 17.2 17.2 Heavy Duty sL100 inT inTernAL sOLiD WALL ‘h’ nominal Lintels are available in increments of 150mm 28 100 140 Light Duty Nominal Height “h” (mm) 28 28 28 Weights (kg/m) 1.2 1.2 1.2 SWL (kN) with 150mm coursing 5 5 5 SWL (kN) with 225mm coursing 7 7 7 NOTE: these loadings are achieved with the composite action of one course of blockwork built on top. The mortar MUST be allowed to harden for at least 24 hours before applying any additional loads. sTAnDArD LenGTHs (mm) sL75 inT 900 1050 1200 Lintels are available in increments of 150mm 28 75 Nominal Height “h” (mm) 28 28 28 Weights (kg/m) 1.1 1.1 1.1 5 7 7 SWL (kN) NOTE: these loadings are achieved with the composite action of one course of blockwork built on top. The mortar MUST be allowed to harden for at least 24 hours before applying any additional loads. Light Duty bAcK… to ‘Contents’ page 34 34 29 17.2 17.2 17.2 Standard Duty sL140 bOX HD 225 225 eXTernAL sOLiD WALL APPLicATiOn ADvAnTAGes Galvanised steel box lintels are designed for use in 200-215mm solid walls and are available in three different designs: box with a lip/toe (SL200 BOX), inverted ‘T’ section (SL200 T) or back to back channel (SL200 CH). Designed to support: • Concrete floor loads • Tile hanging • Masonry loads • Timber floor joists • Attic truss loads and/or roof trusses • Point loads for example compound trusses, steel beams etc • SL200 BOX is designed to support 19:1 load ratio • SL200 CH and SL200 ‘T’ are designed to support 1:1 load ratio • Easy to install • Inverted ‘T’ and back to back channel sections can be used to carry fair facing brick walls on both sides • Can be used in tile-hanging external walls • Galvanised coating ensures durability/longevity • Suitable for use under various loading conditions % 0870 7503167 if in doubt please contact our technical department on ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE insTALLATiOn nOTes See page 46 for general installation notes. bAcK… to ‘Contents’ page eXTernAL sOLiD WALL Additional requirements for sL200 cH and sL200 ‘T’ type lintels: • To avoid excessive deflection and possible twisting, lintels should be adequately propped during construction at maximum 1.2 metre centres. Props should only be removed after the mortar has cured. • To achieve stated loading figures, SL200 CH lintels MUST be filled with well cured masonry before work proceeds over. 35 sTAnDArD LenGTHs (mm) sL200 bOX ‘h’ nominal Lintels are available in increments of 150mm 200 600 1650 2250 2850 3150 3750 4650 1500 2100 2700 3000 3600 4500 4800 Nominal Height “h” (mm) 150 150 150 Weights (kg/m) 9.9 9.9 14.8 18.4 18.4 18.4 18.4 SWL 19:1 (kN) 37 26 27 RM (kNm) 6.4 6.4 8.6 225 52 225 43 sTAnDArD LenGTHs (mm) ‘h’ nominal Lintels are available in increments of 150mm 200 600 1650 1950 1500 1800 2700 Nominal Height “h” (mm) 150 Weights (kg/m) 14.8 18.4 18.4 SWL 19:1(kN) 50 RM (kNm) 8.6 225 65 225 58 18.5 18.5 Heavy Duty sTAnDArD LenGTHs (mm) sL200 ‘T’ ‘h’ nominal Lintels are available in increments of 150mm 200 600 1500 2250 1350 2100 2700 Nominal Height “h” (mm) 75 95 Weights (kg/m) 7.7 8.7 12.5 SWL 1:1(kN) 12 10 24 175 RM (kNm) 1.9 2.5 4.2 See installation notes page 35 Standard Duty sTAnDArD LenGTHs (mm) sL200 cH 225 Lintels are available in increments of 150mm 200 Heavy Duty eXTernAL sOLiD WALL bAcK… to ‘Contents’ page 600 1650 1950 2550 3150 1500 1800 2400 3000 3900 231 231 Nominal Height “h” (mm) 231 Weights (kg/m) 17.6 17.6 17.6 17.6 17.6 231 231 SWL 1:1(kN) 90 80 67 53 40 RM (kNm) 19 19 19 19 19 See installation notes page 35 36 34 32 18.5 18.5 18.5 18.5 Standard Duty sL200 bOX HD 225 255 PresTresseD cOncreTe APPLicATiOn imPOrTAnT nOTes Designed to support: • Masonry loads • Uniformly distributed timber floor loads • Uniformly distributed roof loads • Concrete floor loads • Attic truss loads • Point loads for example compound trusses, steel beams etc • The loading figures published in the loadspan tables represent the Uniform Distributed Serviceable Load (UDL) in kN/m which can be supported by the lintel without the provision of structural brickwork/blockwork over. This is known as Independent Design. • Lintel lengths shown greyed out within the loadspan table are available in longer lengths than the maximum clear span would normally allow. These longer lengths lintels should be used over a series of openings (with intermediate supports) NOT exceeding the maximum clear span and NOT simply supported at each end (i.e. all 65mm/70mm deep lintels must not clear span more than 1800mm). ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE insTALLATiOn nOTes See page 47 for general installation notes. Additional requirements for lintels supporting concrete floor units • Check that the correct lintel has been installed. • Minimum recommended lintel depth is 140mm in order to absorb the shock loading of concrete floor. Precast flooring units should be laid on a mortar bed across the whole wall width and should not be dragged over supports. % 0870 7503167 if in doubt please contact our technical department on ADvAnTAGes bAcK… to ‘Contents’ page PresTresseD cOncreTe • Easy to install and suitable for a variety of applications: internal partitions, external cavity walls, garages, over services. • We offer a wide range of lintels from 100 x 65 through to 220 x 140 catering for every circumstance, with both ‘Universal’ and ‘Hi-Strength’ derivatives where required. • If required, Stressline can schedule and deliver in house plots. 37 STANDARD LENGTHS (mm) 100 x 65 65 100 600 750 900 1050 1200 1350 1500 1650 1800 2100 2400 2700 3000 Clear Span (mm) 300 450 600 750 900 1050 1200 1350 1500 1800 2100 2400 2700 Weight (kg/m) 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 UDL (kN/m) 23.9* 23.9* 13.8* 8.9 RM (kNm) 0.8 0.8 0.8 *UDL is restricted by shear Minimum manufactured length is 450mm 100 x 70 Hi-Strength 70 100 STANDARD LENGTHS (mm) 140 STANDARD LENGTHS (mm) 1.2 1.2 140 220 prestressed CONCRETE 65 0.8 0.8 0.8 0.8 Maximum manufactured length is 3000mm 1.2 300 750 600 4.0 2.8 1.2 1.2 Maximum manufactured length is 2400mm 900 1050 1200 1350 1500 1800 2100 2400 2700 3000 3300 3900 Weight (kg/m) 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 UDL (kN/m) 56.0* 40.2* 28.2 21.8 17.3 13.6 11.4 8.1 3.7 3.7 3.7 STANDARD LENGTHS (mm) 3.7 3.7 3.7 3.7 3.7 6.1 4.6 3.6 2.9 2.4 1.5 3.7 3.7 3.7 3.7 3.7 3.7 Maximum manufactured length is 4200mm 600 1050 1200 1350 1500 1650 1800 2100 2400 2700 3000 3300 3600 4200 900 300 750 600 Clear Span (mm) 900 1050 1200 1350 1500 1800 2100 2400 2700 3000 3300 3900 Weight (kg/m) 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 UDL (kN/m) 68.7* 49.9* 40.2 35.0 27.0 21.9 17.7 12.5 9.2 5.8 5.8 5.8 STANDARD LENGTHS (mm) 5.8 5.8 5.8 5.8 5.8 5.8 7.1 5.6 4.5 3.7 2.6 5.8 5.8 5.8 5.8 5.8 Maximum manufactured length is 4200mm 600 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200 Clear Span (mm) 300 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 Weight (kg/m) 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 UDL (kN/m) 67.6* 67.6* 51.4 44.5 35.3 23.7 17.5 13.2 10.3 8.3 8.7 8.7 8.7 *UDL is restricted by shear Minimum manufactured length is 600mm STANDARD LENGTHS (mm) 140 0.8 600 1050 1200 1350 1500 1650 1800 2100 2400 2700 3000 3300 3600 4200 900 Clear Span (mm) RM (kNm) 140 x 65 0.8 23.9* 11.0 6.3 *UDL is restricted by shear Minimum manufactured length is 600mm 100 1.8 UDL (kN/m) RM (kNm) R22A 100 x 220 2.6 16.5 16.5 16.5 16.5 16.5 16.5 *UDL is restricted by shear Minimum manufactured length is 600mm 100 3.2 Weight (kg/m) RM (kNm) 100 x 140 Hi-Strength 4.1 900 1200 1500 1800 2100 2400 *UDL is restricted by shear Minimum manufactured length is 600mm 100 5.3 Clear Span (mm) 600 900 1200 1500 1800 2100 RM (kNm) R15A 100 x 140 0.8 6.5 8.7 8.7 8.7 8.7 8.7 8.7 8.7 6.8 5.7 4.8 3.6 8.7 8.7 8.7 8.7 Maximum manufactured length is 4200mm 600 900 1050 1200 1350 1500 1800 2100 2400 2700 3000 Clear Span (mm) 300 600 750 900 1050 1200 1500 1800 2100 2400 2700 Weight (kg/m) 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 UDL (kN/m) 33.0* 18.8* 12.3 8.6 RM (kNm) 1.0 1.0 1.0 *UDL is restricted by shear Minimum manufactured length is 600mm BACK… to ‘Contents’ page 38 1.0 6.3 4.8 3.1 2.1 1.0 1.0 1.0 1.0 Maximum manufactured length is 3000mm 600 1050 1200 1350 1500 1650 1800 2100 2400 2700 3000 3300 3600 4200 900 300 750 600 Clear Span (mm) 900 1050 1200 1350 1500 1800 2100 2400 2700 3000 3300 3900 Weight (kg/m) 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 UDL (kN/m) 48.8* 35.9* 26.3 19.3 15.2 11.8 9.9 RM (kNm) 2.9 2.9 2.9 *UDL is restricted by shear Minimum manufactured length is 600mm STANDARD LENGTHS (mm) R15 140 x 100 2.9 2.9 2.9 2.9 6.9 5.1 3.9 3.1 2.5 2.1 1.2 2.9 2.9 2.9 2.9 2.9 2.9 2.9 140 100 STANDARD LENGTHS (mm) Maximum manufactured length is 4200mm 600 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 140 x 140 Hi-Strength 140 Clear Span (mm) 300 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 47.9 47.9 47.9 47.9 47.9 47.9 47.9 47.9 47.9 47.9 47.9 47.9 UDL (kN/m) 67.5* 67.5* 57.9 52.1 39.2 26.5 18.6 13.8 10.6 8.4 RM (kNm) 8.8 8.8 8.8 *UDL is restricted by shear Minimum manufactured length is 600mm STANDARD LENGTHS (mm) 8.8 8.8 8.8 8.8 8.8 8.8 8.8 6.7 5.5 8.8 8.8 14 0 Weight (kg/m) Maximum manufactured length is 3600mm 600 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200 RW22A 140 x 220 140 Clear Span (mm) 300 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 Weight (kg/m) 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 UDL (kN/m) 83.1* 83.1* 68.2 63.3 58.4 47.0 33.9 25.6 20.0 16.1 13.2 11.0 9.3 RM (kNm) 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 *UDL is restricted by shear Minimum manufactured length is 600mm STANDARD LENGTHS (mm) 220 7.3 Maximum manufactured length is 4200mm 600 900 1050 1200 1500 1800 2100 2400 2700 3000 220 x 65 Clear Span (mm) 300 600 750 900 1200 1500 1800 2100 2400 2700 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 UDL (kN/m) 36.4* 36.4* 23.7 17.0 9.8 220 65 Weight (kg/m) RM (kNm) 1.9 1.9 1.9 *UDL is restricted by shear Minimum manufactured length is 600mm 1.9 4.4 1.9 1.9 Maximum manufactured length is 3000mm 600 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200 R22 220 x 100 Clear Span (mm) 300 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 UDL (kN/m) 49.0* 49.0* 26.0 19.3 14.8 RM (kNm) 3.0 3.0 3.0 *UDL is restricted by shear Minimum manufactured length is 600mm STANDARD LENGTHS (mm) 3.0 3.0 9.4 6.5 4.7 3.5 2.7 2.1 1.6 1.3 1.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 220 100 Weight (kg/m) Maximum manufactured length is 4200mm 600 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200 RW22 220 x 140 220 Weight (kg/m) 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 UDL (kN/m) 76.0* 76.0* 54.9 50.8 46.7 30.9 22.0 16.4 12.7 10.2 8.3 RM (kNm) 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 *UDL is restricted by shear Minimum manufactured length is 600mm 6.9 5.8 4.2 14 0 Clear Span (mm) 300 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 Maximum manufactured length is 4200mm 39 BACK… to ‘Contents’ page prestressed CONCRETE STANDARD LENGTHS (mm) 1.9 6.3 ArcH FOrmers APPLicATiOn White uPVC Arch Formers are used over openings in external walls and provide a low cost solution to help form low rise (75mm and 150mm) brick arches. The facia is formed from uPVC which is bonded to high density EPS. Arch Length (mm) rise (mm) Arch reference Arch Length (mm) rise (mm) Arch reference 475 75 475 x SL75 Arch Former 1585 150 1585 x SL150 Arch Former 625 75 625 x SL75 Arch Former 1916 150 1916 x SL150 Arch Former 685 75 685 x SL75 Arch Former 1950 150 1950 x SL150 Arch Former 750 75 750 x SL75 Arch Former 1975 150 1975 x SL150 Arch Former 825 75 825 x SL75 Arch Former 2035 150 2035 x SL150 Arch Former 860 75 860 x SL75 Arch Former 2125 150 2125 x SL150 Arch Former 925 75 925 x SL75 Arch Former 2250 150 2250 x SL150 Arch Former 1025 75 1025 x SL75 Arch Former 2325 150 2325 x SL150 Arch Former 1050 75 1050 x SL75 Arch Former 2425 150 2425 x SL150 Arch Former 1085 75 1085 x SL75 Arch Former 2530 150 2530 x SL150 Arch Former 1135 75 1135 x SL75 Arch Former 2575 150 2575 x SL150 Arch Former 1225 75 1225 x SL75 Arch Former 2596 150 2596 x SL150 Arch Former 1325 75 1325 x SL75 Arch Former 2725 150 2725 x SL150 Arch Former 1350 75 1350 x SL75 Arch Former 1375 75 1375 x SL75 Arch Former 1485 75 1485 x SL75 Arch Former 1525 75 1525 x SL75 Arch Former 1585 75 1585 x SL75 Arch Former 1625 75 1625 x SL75 Arch Former 1675 75 1675 x SL75 Arch Former 1700 75 1700 x SL75 Arch Former 1785 75 1785 x SL75 Arch Former 2035 75 2035 x SL75 Arch Former 2125 75 2125 x SL75 Arch Former 2250 75 2250 x SL75 Arch Former ArcH FOrmers bAcK… to ‘Contents’ page 40 sPeciALs APPLicATiOn inFOrmATiOn reQUiremenTs Stressline Special Lintels are designed and manufactured to suit the most innovative of window designs and styles including: • Semi-circular arch • Segmental arch • Parabolic arch • Gothic arch • Venetian arch • Apex lintel • Corner lintel • Splayed bay lintel • Square bay lintels To enable us to provide a quick and cost effective service, please provide our Technical Office with all the relevant information regarding: wall construction (inner leaf, cavity width, outer leaf), structural opening (clear span), arch rise or radius, loadings supported by the lintel (i.e. masonry loads, floor/roof loads). insTALLATiOn nOTes See page 46 for general installation notes. Please refer to forms overleaf. % 0870 7503167 if in doubt please contact our technical department on ADvAnTAGes • Easy to install and suitable for a variety of applications • Galvanised coating ensures durability/longevity • Built-in plaster key – perforated base plate to inner flange • Excellent thermal efficiency of no more than 0.32 W/mK for cavity wall construction • Available for solid wall construction • Corner lintels and bay lintels can be supplied with corner posts 41 sPeciALs bAcK… to ‘Contents’ page LINTEL DIMENSIONS SEMI-CIRCULAR ARCH LINTEL R A B A mm Outer leaf mm Inside only Rise R mm Cavity width mm Both sides End bearing B mm Inner leaf mm None WALL CONSTRUCTION PLASTER KEY REQUIREMENTS (please tick) Clear span A mm Outer leaf mm Inside only Rise R mm Cavity width mm Both sides End bearing B mm Inner leaf mm None LINTEL DIMENSIONS R A WALL CONSTRUCTION PLASTER KEY REQUIREMENTS (please tick) Clear span A mm Outer leaf mm Inside only Rise R mm Cavity width mm Both sides End bearing B mm Inner leaf mm None B LINTEL DIMENSIONS GOTHIC ARCH LINTEL R A A B PARABOLIC ARCH LINTEL B Clear span LINTEL DIMENSIONS R B PLASTER KEY REQUIREMENTS (please tick) B SEGMENTAL ARCH LINTEL B WALL CONSTRUCTION PLASTER KEY REQUIREMENTS (please tick) Clear span A mm Outer leaf mm Inside only Rise R mm Cavity width mm Both sides End bearing B mm Inner leaf mm None B SPECIALS BACK… to ‘Contents’ page WALL CONSTRUCTION 42 LINTEL DIMENSIONS WALL CONSTRUCTION PLASTER KEY REQUIREMENTS (please tick) Overall Clear Span A1 mm Outer leaf mm Inside only Arch Span A2 mm Cavity width mm Both sides R mm Inner leaf mm None End bearing B mm Rise Arch Span A2 WALL CONSTRUCTION PLASTER KEY REQUIREMENTS (please tick) Clear Span A mm Outer leaf mm Inside only Rise R mm Cavity width mm Both sides End bearing B mm Inner leaf mm None X R B LINTEL DIMENSIONS Angle VENETIAN ARCH LINTEL Overall Clear Span A1 APEX LINTEL R º x° B LINTEL DIMENSIONS B WALL CONSTRUCTION PLASTER KEY REQUIREMENTS (please tick) Span A mm Outer leaf mm Inside only Span B mm Cavity width mm Both sides Inner leaf mm None B A CORNER LINTEL B A Do not allow for bearing. This will be added at design stage LINTEL DIMENSIONS 90° WALL CONSTRUCTION PLASTER KEY REQUIREMENTS (please tick) Span A mm Outer leaf mm Inside only Span B mm Cavity width mm Both sides Span C mm Inner leaf mm None Angle X º SPLAYED BAY LINTEL B C A X° LINTEL DIMENSIONS WALL CONSTRUCTION PLASTER KEY REQUIREMENTS (please tick) Span A mm Outer leaf mm Inside only Span B mm Cavity width mm Both sides Span C mm Inner leaf mm None SQUARE BAY LINTEL B A 90 ° 43 BACK… to ‘Contents’ page SPECIALS Do not allow for bearing. This will be added at design stage C PADSTONES APPLICATION Padstones are generally specified by engineers and architects to help spread heavy point loads across the block or brick walls. % 0870 7503167 If in doubt please contact our technical department on COMPRESSIVE STRENGTH Stressline padstones are manufactured in a variety of sections and lengths with a standard concrete strength of 40 N/mm². Other concrete strengths can be achieved on application. All padstones may be used in any orientation. FINISHES Stressline padstones are made from wet cast concrete in steel pan moulds providing a smooth finish. For longer lengths we can provide a reinforced concrete unit with a concrete strength of 50N/mm². Length (mm) Height (mm) Width (mm) Weight (kg) Part Number 300 140 102 10 CPAD141030 215 140 215 16 CPAD142121 215 215 102 11 CPAD211021 440 140 102 14 CPAD141044 440 140 215 32 CPAD142144 440 215 102 23 CPAD211044 215 140 102 7 CPAD141021 300 215 102 16 CPAD211030 440 215 190 42 CPAD211944 PADSTONES BACK… to ‘Contents’ page 44 Other Stressline Products Beam & Block Flooring •Prestressed Flooring •‘I’ Beam Design •Various Sections •End Slips 225 deep beam and thermal flooring options available. Precast Sections •Stair Flights •Landings •Balconies •Wall Panels •Free Standing Retaining Walls Design and installation service option available Hollowcore Flooring •Prestressed Concrete •Spans in excess of 9m •150mm & 200mm Concrete Fencing and Walling Products •Slotted Posts •Gravel Boards •Support Posts •Morticed and Recessed Posts •Chain Link & Cranked Top Posts •Screed Rails and Bollards •Pier Caps •Copings Wet Cast and Light Weight Variants Available 45 BACK… to ‘Contents’ page Other Stressline Products Design and installation service option available TECHNICAL – STEEL LINTELS MATERIAL SPECIFICATION Stressline standard galvanised steel lintels are manufactured from DX51D grade steel to BS EN 10327: 2004, with a zinc coating type Z600, giving a minimum zinc coating of 600g/m² including both sides. All cut edges are treated with corrosion resistant paint. RS and RSC lintels are manufactured from structural steel plate of grade S275 to BS EN 10025-2: 2004. • • • INSULATION Lintels used in external walls are fully insulated with expanded polystyrene. QUALITY Stressline products are manufactured to the highest quality, under strict control, and comply with all relevant British Standards. We are continually assessed by the BSI to ensure our quality assurance systems comply with BS EN ISO 9001: 2008. COSHH Products are considered non-hazardous to health under normal use. Material data sheets are available from our technical department upon request. STRUCTURAL PERFORMANCE The loadings published in the load-span tables were achieved in accordance with BS EN 845-2: 2003 and tested in accordance with BS EN 846-9: 2000. Stated figures represent the Total Serviceable Uniform Distributed Load (UDL) in kN. ‘CXHD’ and ‘CH’ type lintels have been tested compositely in accordance with BS EN 846-9: 2000 with the surrounding masonry built in accordance with BS 5628. The structural performance of our lintels is supported by continuous in-house testing. TECHNICAL – STEEL Load Ratios are always expressed as inner leaf to outer leaf: 1:1 – lintels supporting masonry only 3:1 – lintels supporting masonry and timber floors 5:1 – lintels supporting concrete floors 19:1 – lintels for eaves applications RECOMMENDATIONS FOR INSTALLATION • Minimum recommended bearing length is 150mm. The lintel should be bedded on mortar and levelled both along the lintel and across its width. Full bricks, blocks or padstones should be used as bearing areas. Do not bear lintels onto cut blocks! • Prior to installation, the lintel should be examined carefully for any defects or signs of damage. • All external wall lintels MUST be installed with a flexible damp proof course (DPC) or cavity tray. BACK… to ‘Contents’ page • 46 In the case of cavity walls the cavity tray should extend not less than 50mm beyond the cavity return. Inner and outer leaves supported by the lintels should be raised together to avoid excessive eccentricity of loading. Masonry must not overhang any flange by more than 25mm. Masonry above the lintel should be allowed to cure before applying floor or roof loads. Composite lintels (i.e. ‘CXHD’, ‘CH’ and ‘RSC’) should be adequately propped during construction, at maximum centres of 1.2 metres. The props should not be removed until the mortar has cured. Ensure that the composite part of the lintel (channel) is fully filled with well-jointed masonry and allowed to cure. Additional recommendations for lintels supporting concrete floor units • Check that the correct lintel has been installed. • Avoid shock loading of lintels during the installation of concrete floor units and any sideways loading while being fitted into position. Precast flooring units should be laid on a mortar bed across the whole wall width and should not be dragged over supports. If you are in doubt as to the structural performance or suitability of a lintel then please contact our Technical department before ordering/installation. ☎ 0870 7503167 If in doubt please contact our technical department on or email technical@stressline.ltd.uk The Stressline technical support desk offers free technical advice to stockists, engineers, architects, builders and private individuals from 8.00 a.m. to 5.00 p.m. Monday to Friday. We offer a free scheduling service providing clear and concise schedules based on your working drawings (plans, elevations, sections, floor/roof layout, etc.). Structural calculations for local authority can be provided upon request to support our specification. We can design and manufacture ‘special’ lintels to suit a variety of innovative opening shapes and cavity wall constructions. State of the art production facilities and design expertise enable us to take an architectural idea and turn it into a functioning product. TecHnicAL – CONCRETE LINTELS sTrUcTUrAL PerFOrmAnce Stressline prestressed concrete lintels are designed in accordance with BS 8110-1: 1997 with a concrete strength of 50 N/mm² or 60 N/mm² and utilizing strands to BS 5896. Lintels are manufactured to BS EN 845-2: 2003. Materials used in the manufacture of Stressline prestressed concrete lintels comply with BS EN 206-1: 2000 and BS 8500. Lintels offer a minimum of ½ hour fire resistance in accordance with Table 4.3 from BS 8110-2: 1985. This can be increased by additional protection as specified in clause 4.2.4 from BS 8110-2: 1985. The structural performance of our lintels is supported by continuous in-house testing. imPOrTAnT nOTes The 100 x 65, R15, R22 and RW22 lintels are ‘Universal’, which means that they can be turned either way round to suit the wall construction. In accordance with good practice, 100 x 70 HiStrength, 140 x 65, 220 x 65 and 140 x 140 Hi-Strength lintels are stamped ‘TOP’ and this surface must be kept at uppermost at all times. Our 100 x 140 Hi-Strength lintels have a groove along the top to enable them to be differentiated from R15 ‘Universal’ lintels. In addition to this, the 100 x 70 Hi-Strength and 100 x 140 Hi-Strength lintels are sprayed with blue paint across the section at one end to avoid confusion with similar sections: 100 x 65 and R15 respectively. QUALiTY cOsHH Products are considered non-hazardous to health under normal use. Material data sheets are available from our technical department upon request. recOmmenDATiOns FOr insTALLATiOn • The lintel should be bedded on mortar and levelled both along the lintel and across its width. Full bricks, blocks or padstones should be used as bearing areas. Do NOT bear lintels onto cut blocks! • recommended minimum bearings are: – 100mm both ends in structural openings up to 1000mm – 150mm both ends in structural openings up to 3000mm – 200mm both ends in structural openings greater than 3000mm LiFTinG AnD sTAcKinG • When using mechanical plant, only 1 layer of units should be lifted at a time and supported at or near ends. • Units should be handled carefully as they will not withstand heavy blows, dropping or reverse bending. • Lifting should be carried out with regard to weather conditions, particularly wind, adequate lifting capacity and lengths of chains. • No lifting should be carried out over work areas. • Load weight should be checked prior to lifting. • Stacking should be the right way up on suitable firm, level ground. • The bearers should be near to the ends and vertically over each other. • Examine units (and infill blocks) for cracks and damage and if present do not use. Additional recommendations for lintels supporting concrete floor units • Check that the correct lintel has been installed. • Avoid shock loading of lintels during the installation of concrete floor units and any sideways loading while being fitted into position. Precast flooring units should be laid on a mortar bed across the whole wall width and should not be dragged over supports. If you are in doubt as to the structural performance or suitability of a lintel then please contact our Technical department before ordering/installation. % 0870 7503167 if in doubt please contact our technical department on or email technical@stressline.ltd.uk Stressline Technical support desk offers free technical advice to stockist, engineers, architect, builders and private individuals from 8.00 a.m. to 5.00 p.m Monday to Friday. We offer free, clear and concise scheduling service based on your working drawings (plans, elevations, sections, floor/roof layout, etc.). If required, we can schedule and deliver lintels in house plots with an easy referencing system to ensure that the correct lintel is used in the chosen location. Structural calculations for local authority can be provided upon request to support our specification. 47 bAcK… to ‘Contents’ page TecHnicAL – cOncreTe Stressline products are manufactured under strict quality control and comply with all relevant British Standards. We are continually assessed by the BSI to ensure our quality assurance systems comply with BS EN ISO 9001: 2008. This does not discharge the installer’s responsibility to ensure that the bearing pressures of the masonry are not exceeded. • Prior to installation, the lintel should be examined carefully for any defects or signs of damage. • All external wall lintels MUST be installed with a flexible damp proof course (DPC). • Masonry must not overhang the lintel by more than 25mm. Stressline Limited Foxbank Industrial Estate Stoney Stanton Leicester LE9 4LX T: 0870 750 3167 F: 0870 750 6379 E: sales@stressline.ltd.uk The information contained in this brochure was accurate at the date of publication. We reserve the right to introduce, at any time, modifications and changes of details that may be deemed necessary. December 2010