MANUFACTURING COMPANY - Berridge Manufacturing Co.

Transcription

MANUFACTURING COMPANY - Berridge Manufacturing Co.
BERRIDGE
MANUFACTURING COMPANY
PRODUCT CATALOG
FREEDOM OF FORM IN ARCHITECTURAL
METAL SYSTEMS
Roofs • Walls • Soffits • Mansards • Ceilings
Fascia • Facades • Equipment Screens • Restoration
Berridge exclusive on-site fabrication
technology provides:
Custom Contoured Panels
Curved Barrel Vault Panels
Tapered Panels
Compound Curved Panels
Long Length Panels
For Technical or Sales Assistance:
(800) 669-0009
www.berridge.com
BERRIDGE ARCHITECTURAL METAL PRODUCTS
General Information ........................................................... 3
Green Sustainable Information........................................... 4
Berridge Standard, Metallic & Premium Colors.................. 5
Berridge Finishes & Material Specifications....................... 6
Berridge Testing Summary Chart ...................................... 7
Standing Seam Roof Systems .....................................8-13
Other Roof Systems ...................................................14-15
8
TEE-PANEL
12
CURVED ZEE-LOCK
BATTEN SEAM
CLASSIC SHINGLE
THIN LINE
19
20
25
Berridge’s unique Total Program is a comprehensive approach
to supplying superior products and services to customers
around the world. The Total Program offers a full range of
precision-tolerance portable roll forming machines, painted
coil and flat sheet, and over 30 panel styles, all backed by
technical and marketing support. The Total Program presents
an unparalleled range of products and depth of service that
has placed Berridge at the forefront of the architectural metal
panel industry.
DEEP DECK
slitting lines, cut-to-length lines, roll formers, mechanical
and hydraulic press-brakes, punch presses, stamping
and bending fixtures, and a variety of special dies. This
complete line of in-house equipment not only produces
top-of-the-line products at the most competitive prices but
assures prompt delivery as well.
PORTABLE ROLL FORMERS
In 1984, Berridge revolutionized the architectural metal panel
industry with the introduction of the Model SS-14 Portable
Roll Former. This unique machine was designed to roll
continuous length, straight, standing seam panels as well
as curved panels. Today, over 10 different panels including
standing seam, soffit and wall panels may be formed using
Berridge portable roll formers. Contact Berridge Sales
Department at 1-800-669-0009 for more information about
the Model SS-14 and other Berridge portable roll formers.
In response to market demand, Berridge developed
reconstructive building products for the restoration of historical
buildings. A complete line of residential roofing and siding
products round out the extensive product line, giving Berridge
the industry’s most comprehensive line of architectural metal
products.
Shop drawings and engineering services for all Berridge
products are available upon request. Contact Berridge’s
Technical Department at 1-800-231-8127 for pricing or
assistance. Architectural details and specifications are
available at www.berridge.com.
Berridge’s modern, high-production equipment provides
customers with low cost, top-quality products. Highly
specialized manufacturing equipment converts large,
bare Galvalume steel coils into pretreated, prefinished,
high quality fabricated architectural sheet metal products.
Berridge equipment includes a continuous coil coating line,
B-6 PANEL
Berridge SS-1421 High Seam Tee-Panel Portable Roll Former can form
straight and curved roof panels in continuous lengths to eliminate panel
end splices. Machine also curves factory formed snap-on seam caps.
Berridge CL-21 Cee-Lock Portable Roll Former forms straight standing
seam roof panels in continuous lengths to eliminate panel end splices.
Machine also inserts patented vinyl weatherseal in female snap-lock leg.
30
29
32
Since 1970, Berridge Manufacturing Company has provided
customers with the industry’s highest quality metal roofing
and siding products. For over 45 years, the company has
specialized in the research and development of architectural
sheet metal products. Many similar products listed in Sweet’s
Catalog were originally designed and developed by Berridge
Manufacturing Company.
EQUIPMENT
HS-8 & HS-12
24
28
31
31
S-TILE
L-PANEL
S-DECK
17
SPANISH TILE
FISH SCALE
FW-12
27
ZEE-LOCK
16
23
22
26
CEE-LOCK
19
RUSTIC SHAKE
12-13
11
15
BERMUDA PANEL
VEE-PANEL
FLUSH SEAM
HIGH SEAM TEE-PANEL
18
21
HR-16
10
14
18
VICTORIAN SHINGLE
Simulated Tile Roof Systems....................................... 16-17
Metal Shingles.............................................................. 18-19
Fascia, Wall & Soffit Panels......................................... 20-27
Exposed Fastener Roof & Wall Panels........................ 28-31
Special Application Products....................................... 32-33
Light-Gauge Framing Components................................... 34
Vantage Point Retrofit Roof System.................................. 35
9
CURVED TEE-PANEL
INTRODUCTION & SERVICE
M-PANEL
32
33
Above: The unique patented Berridge Vinyl WeatherSeal, which is used on
all standing seam and Bermuda Panel systems, provides extra watertight
integrity.
R-PANEL
2
DOUBLE RIB
FLUTED FASCIA
CURVED FLAT SEAM
ARCH. PRIVACY FENCING
Right: Curved Panel Applications are possible with Berridge Portable
Roll-Formers. Curved standing seam roof panels are curved at the job site.
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
3
BERRIDGE IS COMMITTED TO “GREEN”
SUSTAINABLE COOL METAL ROOFING
BERRIDGE MANUFACTURING COMPANY
KYNAR 500® HYLAR 5000™
COLOR FINISHES
(800) 669-0009
www.berridge.com
Energy Star is
only valid in the
United States.
STANDARD COLORS
Due to limitations in the printing process, please request actual color chips for accurate color viewing.
BERRIDGE METAL ROOFING IS COOL & SUSTAINABLE
The high reflectivity, emissivity and solar reflectance
index (SRI) of Berridge metal roofing helps mitigate the
heat island effect. Berridge’s Kynar 500® & Hylar 5000™
cool metal roof colors are optimal for reducing energy
consumption, particularly where cooling loads dominate.
For LEED® compliance, reference SRI values for Berridge
color finishes below.
Berridge Colors
Solar
Reflectivity % Emissivity
PARCHMENT
ALMOND
AGED BRONZE
SHASTA WHITE
FOREST GREEN
PATINA GREEN
SIERRA TAN
MEDIUM BRONZE
CHARCOAL GREY
HEMLOCK GREEN
BRISTOL BLUE
TERRA-COTTA
DARK BRONZE
ZINC GREY
HARTFORD GREEN
ROYAL BLUE
COLONIAL RED
COPPER BROWN
MATTE BLACK
TEAL GREEN
BURGUNDY
DEEP RED
SRI
Almond
67.10
0.90
82
Aged Bronze
29.66
0.86
30
Antique Copper Cote
29.30
0.85
29
Award Blue
17.20
0.83
12
Bristol Blue
30.30
0.86
31
Buckskin
39.71
0.86
43
Burgundy
30.05
0.85
30
Champagne
34.95
0.85
36
Charcoal Grey
29.64
0.87
30
Colonial Red
33.03
0.85
34
Copper Brown
29.57
0.87
30
Copper-Cote
45.24
0.87
51
Dark Bronze
28.20
0.91
30
Deep Red
38.54
0.84
41
Forest Green
29.08
0.85
29
Hartford Green
28.20
0.90
30
Hemlock Green
30.92
0.83
30
Lead-Cote
32.90
0.90
35
Matte Black
28.70
0.91
30
Medium Bronze
31.39
0.85
32
Natural White
75.93
0.84
93
Parchment
51.72
0.83
58
Patina Green
34.42
0.86
36
Preweathered Galvalume
33.61
0.80
32
Royal Blue
29.90
0.90
32
Shasta White
60.00
0.84
70
Sierra Tan
34.81
0.84
36
Teal Green
28.10
0.89
29
Terra-Cotta
31.66
0.83
31
Zinc-Cote
52.45
0.87
61
Zinc Grey
37.88
0.84
40
Satin Finish Galvalume
74.00
0.14
67
Acrylic Coated Galvalume
67.00
0.06
55
RECYCLED CONTENT OF BERRIDGE METAL
Berridge metal products have a high recycled
content and are 100% recyclable at the end of
their lifespan. Using building products that
incorporate recycled materials helps reduce
the impacts resulting from the extraction and
processing of natural resources.
Post-consumer steel recycled content 25.6%
Pre-consumer steel recycled content 6.8%
TOTAL RECYCLED CONTENT 32.9%
LEED® COMPLIANCE
SRI Values are provided by Berridge’s paint supplier and may vary slightly. Reference
www.berridge.com for the most up-to-date information on Berridge SRI Values.
4
BUCKSKIN
In addition to meeting LEED criteria for SS Credit 7.2: Heat Island
Effect and for MR Credit 4: Recycled Content, using Berridge
metal products can contribute to other LEED points. Reference
the Technical Bulletins section at www.berridge.com for more
information on Berridge’s compliance with LEED. While every
effort has been made to provide accurate information, applicants
for LEED Certification should verify compliance with a LEED
expert. For more information on LEED 2009 certification visit
www.usgbc.org.
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
PREMIUM COLORS
METALLIC COLORS
Berridge premium colors require a nominal surcharge.
NATURAL WHITE
Berridge metallic colors are premium finishes which require a nominal surcharge.
Due to limitations in the printing process, please request actual color chips for accurate color viewing.
AWARD BLUE
CHAMPAGNE
COPPER-COTETM
ANTIQUE
COPPER-COTE
LEAD-COTETM
PREWEATHERED
GALVALUME®
NATURAL METAL FINISH
Berridge Acrylic-Coated
Galvalume® is a coated
sheet product that combines
the corrosion resistance of
GALVALUME® steel sheet with
a clear, organic resin applied to
the top side and bottom side of
GALVALUME® substrate.
ACRYLIC-COATED
GALVALUME®
ZINC-COTETM
All colors except Award Blue comply with LEED® v3 & Energy Star requirements for steep slope roofs greater than 2:12. Almond & Natural White comply with
LEED® v3 requirements for low slope roofs, 2:12 or less. Natural White also complies with Energy Star requirements for low slope roofs, 2:12 or less.
5
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
KYNAR 500® OR HYLAR 5000TM COLORS & NATURAL METAL FINISHES
BERRIDGE TESTING SUMMARY CHART (Steel Substrate, consult Berridge for Aluminum Testing)
All Berridge-applied colors are premium fluoropolymer coatings produced with
full strength Kynar 500® or Hylar 5000™ resin. Kynar 500® or Hylar 5000™ affords
maximum exterior durability due to its outstanding resistance to ultraviolet radiation.
Full-strength Kynar 500® or Hylar 5000™ color finishes carry a 20-year warranty
against cracking, peeling and fading (not to exceed 5 N.B.S. units). These are the
highest quality exterior finishes available!
* Metallic Finishes are premium colors which require a nominal surcharge.
UL
790
UL
263
Tee Panel
Zee-Lock Panel (Double Lock)*
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
OTHER ROOF SYSTEMS
UL
90
UL
1897
UL
790
UL
263
Bermuda Roof Panel
• •
•
•
• •
•
•
•
•
•
•
• •
• •
• •
Zee-Lock Panel (Single Lock)*
Spanish Tile Roof System
Berridge owns and operates its own modern continuous coil coating line in San Antonio,
Texas, painting both 48” and 42” wide Galvalume® master coils.
S-Tile Roof Panel
Batten Seam Roof System
Victorian & Classic Shingles
COATING SYSTEM
Protective Strippable Film (painted material only)
ACRYLIC-COATED GALVALUME®
Acrylic-Coated Galvalume® (ACG) is a coated sheet product that combines the
corrosion resistance of GALVALUME® steel sheet with a clear, acrylic coating that is
applied over GALVALUME® substrate. The surface treatment is essentially invisible
but it provides excellent characteristics to enhance the performance and applicability
of GALVALUME® steel sheet. These enhancements include: good roll-formability
without the need for oils, excellent transit and field-storage performance without
staining, dramatic decrease in finger printing or foot printing during installation
and long term surface brightness when exposed to the environment. It is applied
at the mill by roll-coating a uniform, thin film of a water-base acrylic solution onto
both surfaces of the sheet.
UL
1897
Cee-Lock Panel*
Metallic colors are processed and finished on Berridge’s continuous coil-coating line.
These proprietary finishes are available for all factory products, flat sheet, and coil.
Flat sheets and coils in metallic finishes are available to sheet metal companies
for fabrication of special profiles, shapes or flashing. Metallic colors are directional
and paint lot sensitive. Large orders should be placed at the same time to avoid
mixing paint lots. Berridge Metallic Finishes include:
ANTIQUE COPPER-COTE
ZINC-COTE™
LEAD-COTE™
UL
90
High Seam Tee Panel
BERRIDGE METALLIC FINISHES*
COPPER-COTE™
CHAMPAGNE
PREWEATHERED GALVALUME®
STANDING SEAM ROOF PANELS
0.75 ± 0.05 mil Kynar500® Hylar5000™ top coat
0.20 ± 0.05 mil primer coat
24 gauge or 22 gauge Galvalume or 0.032
or 0.040 Aluminum substrate
®
0.35 ± 0.05 mil total dry film thickness for
primer coat (non-metallics only)
Beige urethane backer coat (all colors)
Notes:
1. Special colors and finishes are available. Please consult Berridge for pricing and delivery.
2. Berridge metallic finishes are premium finishes and require a nominal surcharge.
3. Galvalume® is a registered trademark of BIEC International, Inc.
4. Kynar 500® is a registered trademark of Arkema, Inc.
5. Hylar 5000TM is a registered trademark of Solvay Solexis.
Rustic Shake Shingle
SHEET METAL MATERIAL
A. Prefinished metal shall be Aluminum-Zinc Alloy Coated (AZ-50 Galvalume®) Steel
Sheet, 24-Gauge or 22-Gauge*, ASTM 792, Grade 40, yield strength 40 ksi min.
or 3105 Alloy Aluminum Sheet 0.032 or 0.040*, ASTM B209, H14 temper, yield
strength 21 ksi min.
D. Unpainted metal shall be Aluminum-Zinc Alloy Coated (AZ-55 Acrylic Coated
Galvalume®) Steel Sheet, 24-Gauge or 22-Gauge*, ASTM 792, Grade 40, yield
strength 40 ksi min., with clear acrylic coating on both sides of material.
E. Field protection must be provided by the contractor at the job site so stacked or
coiled material is not exposed to weather and moisture.
B. Finish shall be full strength Kynar 500® or Hylar 5000™ fluoropolymer coating
applied by the manufacturer on a continuous coil coating line, with a top side
dry film thickness of 0.75 ± 0.05 mil over 0.20 ± 0.05 mil prime coat, to provide
a total top side dry film thickness of 0.95 ± 0.10 mil. Bottom side shall be coated
with a primer (non-metallics only) and beige urethane coating with a total dry
film thickness of 0.35 ± 0.05 mil. Finish shall conform to all tests for adhesion,
flexibility, and longevity as specified by the Kynar 500® or Hylar 5000™ finish
supplier.
F. Flashing may be factory fabricated or field fabricated. Unless otherwise specified
all exposed adjacent flashing shall be of the same material and finish as panel
system.
C. Strippable film shall be applied to the top side of all prefinished metal to protect
the finish during fabrication, shipping and field handling. This strippable film
MUST be removed immediately before installation.
*Not all products and colors are available in 22-Gauge or Aluminum substrate.
Consult Berridge for product and color availability in 22-Gauge Galvalume
and Aluminum substrate.
Note: The rolling process of sheet metal results in inherent surface unevenness referred
to as “oil-canning”. This condition is also caused by several factors including thermal
expansion and contraction, dark colors, both medium and high-gloss finishes, and
uneven substrate. “Oil-canning” in itself is not sufficient cause for material rejection.
For complete specifications visit www.berridge.com
6
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
UL ASTM ASTM ASTM ASTM ASTM ASTM ASTM FM
2218 E 1592 E 330 E 2140 E 1646 E 1680 E 331 E 283 4471
•
•
•
•
•
FL
PROD
APP
MIAMI
DADE
•
•
•
•
•
•
•
FL
PROD
APP
MIAMI
DADE
•
•
•
•
•
•
•
Curved Flat Seam Panel
Double Rib Panel
• •
•
•
•
•
•
FASCIA, WALL & SOFFIT PANELS
UL
90
UL
790
"R" Panel
"M" Panel
Deep Deck Panel
S-Deck
UL
1897
•
•
•
•
•
UL
263
•
•
•
•
•
•
HR-16 Panel
HS Wall Panels
FW-12 & FW-1025 Panels
Thin Line Panel
•
•
•
•
•
•
•
UL ASTM ASTM ASTM ASTM ASTM ASTM ASTM FM
2218 E 1592 E 330 E 2140 E 1646 E 1680 E 331 E 283 4471
Flush Seam Panel
L-Panel
SPECIFICATIONS FOR ALL 24 & 22-GAUGE GALVALUME* & 0.032 & 0.040 ALUMINUM* BERRIDGE PRODUCTS
•
UL ASTM ASTM ASTM ASTM ASTM ASTM ASTM FM
2218 E 1592 E 330 E 2140 E 1646 E 1680 E 331 E 283 4471
•
FL
PROD
APP
•
•
•
•
•
•
•
•
•
•
•
•
MIAMI
DADE
•
•
•
Vee-Panel
B-6 Panel
•
Fluted Fascia Panel
•
For actual test results, technical questions, fastener types, fastener spacing, or job-specific engineering, please contact Berridge’s Technical Department at (800) 669-0009.
Updates and additional testing are added on a continual basis. Consult Technical Dept. for the latest updates.
*Use continuous ribs for ASTM E 1646, ASTM E 1680, ASTM E 331, and ASTM E283 compliance.
UL 90 - Uplift Tests of Roof System
UL 1897 - Uplift Tests of Roof System
UL 790 - Fire Tests of Roof System
UL 263 - Fire Tests of Construction and Materials
UL 2218 - Impact Resistance of Prepared Roof
Covering Materials
ASTM E-1592 - Structural Performance of Sheet
Metal Roof and Siding Systems by Uniform Static Air
Pressure Difference
ASTM E-330 - Structural Performance of Exterior
Windows, Doors, Skylights and Curtain Walls by
Uniform Static Air Pressure Difference
ASTM E-2140 - Water Penetration of Metal Roof
Panel Systems by Static Water Pressure Head
ASTM E-1646 - Water Penetration of Exterior Metal
Roof Panel Systems by Uniform Static Air Pressure
Difference
ASTM E-1680 - Rate of Air Leakage Through Exterior
Metal Roof Panel Systems
ASTM E-331 - Water Penetration of Exterior
Windows, Skylights, Doors, and Curtain Walls by
Uniform Static Air Pressure Difference
ASTM E-283 - Rate of Air Leakage Through Exterior
Windows, Curtain Walls, and Doors Under Specified
Pressure Differences Across the Specimen
FM 4471 - This standard states Approval requirements
for Class 1 Panel Roofs. A Class 1 Panel Roof meets
the criteria of this standard for fire, wind, foot traffic &
hail damage resistance.
Florida Product Approval - Standard of practice for
product evaluations and consistency of enforcement
for the state of Florida.
Miami-Dade Approval - Established with its
main goal to allow new and innovated ideas to be
developed into useful, practical, lasting and safe
products for use in High Velocity Hurricane Zones.
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
7
STANDING SEAM METAL ROOF SYSTEMS
Berridge Curved, Compound
Curved & Tapered Tee-Panel
Metal Standing Seam with exclusive
patented vinyl weatherseal as an integral
part of Snap-On Seam. For residential
or commercial construction with solid
sheathing.
Metal Standing Seam with exclusive patented vinyl
weatherseal as an integral part of Snap-On Seam.
Concave, convex, or compound curved corners
and domed roof construction with
solid sheathing.
• Available in 24 gauge steel & 0.032 aluminum
• Extruded vinyl weatherseal as integral part
of Snap-on seam cap
• Concealed fasteners
• UL 580 tested
• UL 90 wind uplift*
• UL fire resistance listed
• ASTM air & water resistance tested
• Florida Product Approval
• May be site-formed in continuous lengths
with Berridge SS-14 portable roll former
• Convex (min 4’) & concave (min 6’)
curving with Berridge SS-14 portable
1” (25 mm)
roll former
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
8
STANDING SEAM METAL ROOF SYSTEMS
Berridge Tee-Panel
12 ¾” Coverage (324 mm)
Snap-On Seam
(with Vinyl Weatherseal)
Tee-Panel
• Available in 24 gauge steel
& 0.032 aluminum
• Extruded vinyl weatherseal as integral part
of Snap-on seam cap
• Concealed fasteners
• UL 580 tested
• UL 90 wind uplift*
• UL fire resistance listed
• ASTM air & water resistance tested
• Florida Product Approval
• Site-formed & curved with Berridge
SS-14 portable roll former (Use SL1” (25 mm)
24 for tapered & SL-1 for compound
curved panels)
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
12 ¾” Coverage (324 mm)
Width at eave varies on tapered Tee-Panel
Snap-On Seam
(with Vinyl Weatherseal)
Tee-Panel
See www.berridge.com for Details and Specifications
Vinyl Weatherseal: US Patent No. 4641475
See www.berridge.com for Details and Specifications
Vinyl Weatherseal: US Patent No. 4641475
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
9
STANDING SEAM METAL ROOF SYSTEMS
Berridge Cee-Lock Panel
Metal Standing Seam with exclusive patented vinyl
weatherseal as an integral part of Snap-On Seam. For
residential or commercial construction with solid sheathing.
Metal Standing Seam with exclusive patented
vinyl weatherseal as an integral part of
Snap-Lock Seam. Residential and
commercial construction with
solid sheathing.
• Available in 22 & 24 gauge steel
& 0.032 aluminum
• Extruded vinyl weatherseal as integral part
of Snap-on seam cap
• Concealed fasteners
• UL 90 wind uplift & UL fire resistance listed
• ASTM air & water resistance tested
• Florida Product Approval
• May be site-formed in continuous lengths
with Berridge SS-1421 portable roll former
• Consult Berridge for minimum radius.
(Striated profile is standard)
18 ¼” Coverage (464 mm)
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
1” or 1 ½”
(25 mm or 38 mm)
Snap-On Seam
(with Vinyl Weatherseal)
High Seam Tee-Panel
See www.berridge.com for Details and Specifications
Vinyl Weatherseal: US Patent No. 4641475
10
• Available in 24 & 22 gauge steel & 0.032 aluminum
• Extruded vinyl weatherseal (optional)
• Concealed fasteners
• Integral snap-lock seam
• Striated profile is available
• UL 580 tested*
• UL 90 wind uplift*
• UL fire resistance listed
• UL 1897 tested*
• ASTM air & water resistance tested
1 ½”
• ASTM E-1592 tested
(38 mm)
• Florida Product Approval*
• Miami-Dade approved
• ICC-ES Report ESR-3486
• May be site-formed in continuous lengths with
Berridge CL-21 portable
roll former
Unless otherwise noted, all
testing is for steel only
*Approved for steel and
aluminum
Cee-Lock Panel
STANDING SEAM METAL ROOF SYSTEMS
Berridge High Seam Tee-Panel
16 ½” Coverage (419 mm)
See www.berridge.com for Details and Specifications
Vinyl Weatherseal
(Optional) is required for
Watertight Warranties.
Cee-Lock Clip or
Continuous Cee-Rib
(Required for WTW)
Vinyl Weatherseal: US Patent No. 4641475
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
Optional panel striations
11
STANDING SEAM METAL ROOF SYSTEMS
Berridge Zee-Lock
Double-Lock
Architectural/Structural standing seam roof
system for use over open purlin framing
or solid sheathing. Straight or curved
applications.
• • • • • •  
•
• • •
•
• • • • • Available in 24 & 22 gauge steel & 0.032 aluminum
Extruded vinyl weatherseal on continuous rib (Optional)
Mechanically seamed sidelap
2” high standing seam sidelap
Optional striated profile available
UL 90 wind uplift
UL fire resistance listed
ASTM air & water resistance tested
ASTM E-1592 tested
UL 580 tested*
UL 1897 tested*
ASTM E-2140 tested
Corps of Engineers CEGS 07416 approved
Florida Product Approval
ICC-ES Report ESR-3486
Continuous lengths when site-formed with
SP-21 portable roll-former
• Site-curved with ZC-21 curving machine
Unless otherwise noted, all testing is for steel only
Architectural/Structural standing seam
roof system for use over open purlin
framing or solid sheathing.
Berridge Curved Zee-Lock
Berridge Single Lock Zee-Lock can be curved to a minimum radius of 20’ using
the Berridge ZC-21 Curver machine. Curving of the panel to be done on-site.
2”
51 mm
11/16”
2”
51 mm
¼”
16” Coverage (406 mm)
11/16”
16” Coverage (406 mm)
*Approved for steel and aluminum
¼”
1 3/16”
ZEE-LOCK PANEL CROSS-SECTION
See www.berridge.com for Details and Specifications
1 3/16”
•  Available in 22 & 24 gauge steel & 0.032 aluminum
•  Mechanically double-locked sidelap
•  2” high standing seam sidelap
•  Optional striated profile available
•  UL 90 wind uplift
• UL fire resistance listed
•  ASTM air & water resistance tested
•  ASTM E-1592 tested
• UL 580 tested*
• UL 1897 tested*
•  ASTM E-2140 tested
•  FMRC Approved & 1-150 SH rated
• Corps. of Engineering CEGS approved
• ICC-ES Report ESR-3486
•  Florida Product Approval
•  Miami-Dade Approval
•  Continuous lengths when site-formed
with SP-21 portable roll-former
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
ZEE-LOCK PANEL CROSS-SECTION
See www.berridge.com for Details and Specifications
The 180-degree
mechanically
seamed Zee-Lock
seam is not
available with vinyl
weatherseal.
Optional Extruded Vinyl
Weatherseal (*US Patent
No. 5134825) Note: Vinyl
Weatherseal required for
open framing and curved
applications as well as for
Watertight Warranties.
Continuous Zee-Rib
Continuous Zee-Rib or Zee-Clip
(Required for WTW)
ZEE-LOCK DOUBLE-LOCK PANEL ASSEMBLY
OPTIONAL
SNAP-ON BATTEN CAP
ZEE-LOCK PANEL ASSEMBLY
The Berridge Zee-Lock
Double-Lock Seamer
double locks the sidelap
seam in a single pass.
Not available for use with
vinyl weatherseal.
The Berridge
Zee-Lock
Seamer locks
the sidelap
seam in a single
pass. Use
continuous
Zee-Rib with
vinyl for best
performance.
Optional panel striations
ZEE-LOCK SECTION PROPERTIES BASED ON 24 GA 40 K.S.I.
ZEE-LOCK
IX (in4/ft)
MA (ft.lbs/ft)
VA (lbs/ft)
Positive Bending
0.1525
184.65
Negative Bending
0.1031
161.33
ZEE-LOCK SECTION PROPERTIES BASED ON 24 GA 40 K.S.I.
ZEE-LOCK
IX (in4/ft)
MA (ft.lbs/ft)
VA (lbs/ft)
990
Positive Bending
0.1525
184.65
990
990
Negative Bending
0.1031
161.33
990
NOTES: Zee-Lock Panel with continuous 24 GA Zee-Rib. Values based on 1996 edition
of AISI and good engineering practice.
12
STANDING SEAM METAL ROOF SYSTEMS
Berridge Zee-Lock
NOTES: Zee-Lock Panel with continuous 24 GA Zee-Rib. Values based on 1996 edition
of AISI and good engineering practice.
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
13
OTHER ROOF SYSTEMS
Berridge Bermuda Panel
Two-part system utilizes Deep Vee Panel
and square Snap-On battens for more
visible seams. May be installed over open
framing or solid sheathing.
Traditional Bermuda roof design.
Continuous length panels
for roof, fascia or mansard.
• • • • • •
• • • • • • • • Available in 24 gauge steel
Concealed fasteners
Spans over open purlins
UL 90 wind uplift & UL fire resistance listed
Florida Product Approval
May be site-formed in continuous lengths
with Berridge BP-21 portable roll-former
Available in 24 gauge steel
Concealed fasteners
Optional vinyl weatherseal
Strong horizontal lines & stepped appearance
Optional wood grain embossed texture
UL 90 wind uplift & UL fire resistance listed
Florida Product Approval
May be site-formed in continuous lengths
using Berridge BP-14 portable roll former
16” Coverage (406 mm)
2”
14
11” Coverage (279 mm)
1”
(25 mm)
Snap-On
Batten Cap
1 ¾”
(45 mm)
Deep-Vee Panel
OTHER ROOF SYSTEMS
Berridge Batten Seam Panel
See www.berridge.com for Details and Specifications
See www.berridge.com for Details and Specifications
Vinyl Weatherseal: US Patent No. 5134825
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
15
SIMULATED TILE ROOF SYSTEMS
Berridge S-Tile
Prefinished metal Spanish Tile System used
with Deep-Vee Panel. Eliminates the need for
solid sheathing and furring strips.
Prefinished metal S-Tile panels with a
clean, crisp simulated tile appearance.
• • • • • • •
• Available in 24 gauge steel
Concealed fasteners
Stronger and lighter than clay tiles
Available in all standard Berridge
Kynar 500® or Hylar 5000TM finishes
May be installed over open framework
UL 580/UL 1897 tested
UL fire resistance listed
Florida Product Approval
8” Width (203 mm)
9” Width (227 mm)
Spanish Tile
Deep-Vee Panel
2”
(51 mm)
1 ½”
(38 mm)
•
•
•
•
• •
•
•
•
•
SIMULATED TILE ROOF SYSTEMS
Berridge Spanish Tile
Available in 24 gauge steel
Exposed fasteners
Light weight: only 1.2 lbs/ft2
Available in all standard Berridge
Kynar 500® or Hylar 5000TM finishes
UL 580/UL 1897 tested
Florida Product Approval
Miami-Dade approved
UL fire resistance listed
ASTM E-1592 tested
Continuous length eave-to-ridge
panels up to 40’ long for fast
installation without panel endlaps
32 11/16“ Coverage (830 mm)
1 ½”
(38 mm)
16” Coverage (406 mm)
3’ min - 40’ max
14” (350 mm)
14” (350 mm)
14” (350 mm)
Eave Closure
See www.berridge.com for Details and Specifications
See www.berridge.com for Details and Specifications
Colors can be mixed. Shown with custom color palette above.
16
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
17
METAL SHINGLES
Berridge Rustic Shake Shingles
Prefinished Kynar 500®, Hylar 5000TM, or Acrylic Coated Galvalume®
traditional shingle for restoration, residential, & commercial construction
with solid sheathing for roofs or walls. Concealed Fasteners. Florida
& Miami-Dade approved. 24 gauge steel. UL 580/UL 1897 tested.
Prefinished heavy-gauge shingles with concealed fasteners
for residential or commercial construction with solid
sheathing. 24 gauge steel.
12” Coverage
(305 mm)
12” Coverage
(305 mm)
9” Coverage
(229 mm)
24” Coverage
(610 mm)
Berridge Classic Shingles
Berridge Fish Scale Shingles
Prefinished Kynar 500®, Hylar 5000TM, or Acrylic Coated Galvalume®
traditional shingle for restoration, residential, & commercial construction
with solid sheathing for roofs or walls. Concealed Fasteners. Florida
& Miami-Dade approved. 24 gauge steel. UL 580/UL 1897 tested.
Historical product for gable, sidewall, steep mansard, or
fascia applications (80°+) with solid sheathing. 24 gauge steel.
8 ½”
(216 mm)
12” Coverage
(305 mm)
9” Coverage
(229 mm)
18
11 ½” Coverage
(292 mm)
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
19
METAL SHINGLES
Berridge Victorian Shingles
FASCIA, WALL & SOFFIT PANELS
Berridge HR-16
Prefinished horizontal or vertical wall
panel. Versatile and maintenance-free.
Prefinished horizontal or
vertical metal wall panel.
• Available in 24 & 22 gauge steel or
0.032 & 0.040 aluminum
• Standard with stucco embossing
• Concealed fasteners
• Multi-purpose wall panel
• May be used horizontally or vertically
• May be used for soffit applications
• Wide rib appearance
• Interlocks with HR-16 wall panel
• Factory formed to 40’ max
•  ASTM air & water resistance tested
• ASTM E-1592 tested*
• Florida Product Approval*
• Consult Berridge for smooth finish availability
• May be used over solid sheathing or open framing
• Available in 24 & 22 gauge steel or
0.032 & 0.040 aluminum
• Standard smooth finish
• Concealed fasteners
• Multi-purpose wall panel
• May be used horizontally or vertically
• Interlocks with HS-8 & HS-12
• Narrow-rib appearance
• Florida Product Approval*
• Miami-Dade Approved
•  ASTM air & water resistance tested
• ASTM E-1592 tested*
• May be used over solid sheathing or open framing
• Factory formed to 40’ max
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
8” Coverage (203 mm)
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
5 5/ 8” (143 mm)
7/ 8”
(22 mm)
HS-8 Wall Panel
16” Coverage (406 mm)
4” (102 mm)
12” Coverage (305 mm)
9 5/ 8” (244 mm)
7/ 8”
(22 mm)
HS-12 Wall Panel
7/ 8”
(22 mm)
1 1/ 8”
(29 mm)
1 5/ 8”
(41 mm)
HR-16 Wall Panel
20
See www.berridge.com for Details and Specifications
See www.berridge.com for Details and Specifications
Detail of HS-12 & HS-8
Panel Interlock
Detail of HR-16
Panel Interlock
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
21
FASCIA, WALL & SOFFIT PANELS
Berridge HS-8
& HS-12
FASCIA, WALL & SOFFIT PANELS
Berridge FW-1025 & FW-12 Panel
Wall, soffit and facade system
versatile and maintenance free
prefinished metal wall panels for open spans
Wall, Liner, or Soffit Panels. Versatile, maintenancefree, prefinished metal wall panels for open spans.
•
•
•
•
•
•
•
• Available in 24 & 22 gauge steel or 0.032 & 0.040 aluminum
• Concealed fasteners
• Optional vee-grooves
• Seam lock feature (optional)
• Striated profile (optional)
• Optional stucco embossed texture
• Panel may be vented
• Soffit and vertical wall applications
• Open framing or solid sheathing
• ASTM air & water resistance tested
• ASTM E-1592*
• Florida Product Approval*
• Miami-Dade Approved
Available in 24 & 22 gauge steel
Concealed fasteners
Vee-groove appearance
Optional wood grain embossed texture
Panel may be vented
Soffit and vertical wall applications
Open framing or solid sheathing
FASCIA, WALL & SOFFIT PANELS
Berridge Vee-Panel
Optional seam lock feature.
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
10 1/4” Coverage (260 mm)
1 1/2”
(38 mm)
Berridge Vee-Panel, vertical wall application.
With a 12” coverage, Berridge FW-12 panel is ideal for large soffit and ceiling applications.
3.4” (86 mm)
12” Coverage (305 mm)
1 1/2”
(38 mm)
4” (102 mm)
12 3/4” Coverage (324 mm)
Available without grooves.
4 1/4” (108 mm)
Available with striations.
3/8”
Berridge Vee-Panel is great for walls, fascia, and soffit applications.
(10 mm)
Vented Vee-Panel Notes: Panel provides 6.46 square
inches of Net Free Vent Area (NFVA) per linear foot
of panel. Berridge Manufacturing Company does not
recommend vented products in applications subject to
aggressive atmospheres, marine environments, or high
humidity due to the corrosive nature of these environments
on raw edges of steel.
Berridge Vee-Panel can be vented for soffit applications.
22
See www.berridge.com for Details and Specifications
Berridge FW-1025 & FW-12 are multipurpose wall and soffit panels.
Available with vents.
Vented FW-1025 & FW-12 Notes: Panel provides
7.79 square inches of Net Free Vent Area (NFVA) per
linear foot of panel. Berridge does not recommend
vented products in applications subject to aggressive
atmospheres, marine environments, or high humidity.
See www.berridge.com for Details and Specifications
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
23
FASCIA, WALL & SOFFIT PANELS
FASCIA, WALL & SOFFIT PANELS
Berridge B-6 Panel
Corrugated metal wall, liner, or
soffit panels for open spans or
solid sheathing.
Berridge L-Panel is an economical and versatile panel for fascia, soffit, liner, and ceiling
applications. Available with 2 grooves, 1 groove or no grooves as shown above.
• 24 gauge steel
• Concealed fasteners
• Use vertically for fascia, facade, or siding
• Self-venting
• Open framing or solid sheathing
• Available in 24 & 22 gauge steel
& 0.032 aluminum
(Consult BMC for 22 gauge)
• Concealed fasteners
• Optional vee-grooves
• Optional stucco embossed texture
• Panel may be vented
• Open framing or solid sheathing
• ASTM E-1592
• Miami-Dade Approved
• May be site-formed using Berridge FP-16
portable roll former
Berridge B-6 Panel is a great option for interior ceiling and wall applications.
11 5/8” Coverage (290 mm)
1”
(25 mm)
6” Coverage (152 mm)
5/ 8”
(16 mm)
3 7/8” (98 mm)
Berridge L-Panel is a great soffit panel and can be site-formed with the FP-16 portable roll former.
Available with one groove.
See www.berridge.com for Details and Specifications
Berridge B-6 Panel is a good option for fascia and soffit applications and provides a sleek,
corrugated appearance.
Available smooth without grooves.
Berridge L-Panel can be vented for soffit applications.
Vented L-Panel Notes: Panel provides 5.19 square inches
of Net Free Vent Area (NFVA) per linear foot of panel.
Berridge Manufacturing Company does not recommend
this product in applications subject to aggressive
atmospheres, marine environments, or high humidity
due to the corrosive nature of these environments on raw
edges of steel.
See www.berridge.com for Details and Specifications
24
Berridge B-6 Panel can be used vertically on curved wall applications.
Berridge B-6 Panel can be used vertically on curved wall applications.
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
25
FASCIA, WALL & SOFFIT PANELS
Berridge Thin-Line
With rigid embossed texture for soft,
uniform reflectivity. Prefinished fascia
or soffit panel for open spans to provide
flat appearance.
Versatile, maintenance-free,
prefinished metal fascia, facade, wall
or soffit panels for open spans.
Berridge Flush Seam’s embossed texture make it a good option for large wall expanses.
•
• • •
•
•
•
•
•
24 gauge steel
Concealed fasteners
Stucco embossed texture
Optional wood grain texture
Use vertically for facade or wall
Self-venting
Open framing or solid sheathing
Florida Product Approval
ASTM air resistance tested
½”
(13 mm)
See www.berridge.com for Details and Specifications
26
24 gauge steel
Concealed fasteners
Channel drain interlock
Narrow panel with smooth appearance
Optional wood grain or stucco
embossed texture
• Use vertically for fascia or wall
• Open framing or solid sheathing
• Florida Product Approval
3 7/8” Coverage (98 mm)
Berridge Flush Seam can be used vertically on curved wall applications. Panel does not curve.
Berridge Flush Seam is a multipurpose wall, soffit, and liner panel and can also be used in
interior ceiling applications as shown above.
• • • • • Picture features close up of optional wood grain texture.
3 5/8” Coverage (91 mm)
Berridge Thin Line is a multipurpose wall,soffit, liner, ceiling and fascia panel.
Berridge Thin Line panel provides smooth, narrow lines.
3/8”
(9 mm)
See www.berridge.com for Details and Specifications
Picture features optional wood grain texture. See page 26 for close up view.
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
27
FASCIA, WALL & SOFFIT PANELS
Berridge Flush Seam
EXPOSED FASTENER ROOF & WALL PANELS
Berridge Deep-Deck
Corrugated structural metal sheathing.
S-Deck may be curved for covered
walkways, shelter covers, etc.
Prefinished corrugated 7.2” roof or
wall panel for use on open framing or
solid sheathing.
• Available in 24 & 22 gauge steel
or 0.032 & 0.040 aluminum
• Vertical and horizontal applications
• 32” panels can be factory curved
• Minimum 5’ radius for curved panels
• ASTM E-1592 tested*
• Florida Product Approval*
• UL fire resistance listed
• Multi-use panel: roof, wall, or sheathing
EXPOSED FASTENER ROOF & WALL PANELS
Berridge S-Deck
36” Coverage (914 mm)
1 ½”
(38 mm)
• Available in 24 & 22 gauge steel
or 0.032 & 0.040 aluminum
• Wide, economical 36” coverage
• Vertical & horizontal applications
• Structural properties
• Purlin bearing leg standard
• Multi-use panel: roof, wall, or deck
• ASTM air & water resistance tested
• ASTM E-1592 tested*
• Florida Product Approval*
• UL 90 & UL fire resistance listed
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
2”
(51 mm)
7.2”
(183 mm)
See www.berridge.com for Details and Specifications
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
Nominal 32” Coverage (813 mm)
7/8”
(22 mm)
2.67”
(68 mm)
Nominal 34.67” Coverage (880 mm)
7/8”
2.67”
(68 mm)
(22 mm)
Curved S-Deck Notes: Curved S-Deck is available in
32” exposure panels only. Berridge recommends lapping
two corrugations on panel side laps when using curved
S-Deck. Exposure will be 29.33” with two laps or 32” with
one lap.
See www.berridge.com for Details and Specifications
28
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
29
EXPOSED FASTENER ROOF & WALL PANELS
Berridge R-Panel
Prefinished or Acrylic Coated
Galvalume, wall, soffit, fascia, mansard,
liner, or equipment screen panel
Prefinished or Acrylic Coated Galvalume,
wall, soffit, fascia, mansard, liner, or
equipment screen panel
• Available in 24 & 22 gauge steel &
0.032 aluminum
• Wide, economical 36” coverage
• Vertical & horizontal applications
• Open framing or solid sheathing
• UL 90 & UL fire resistance listed
• Florida Product Approval
• Available in 24 & 22 gauge steel
& 0.032 aluminum
• Wide, economical 36” coverage
• Vertical & horizontal applications
• Open framing or solid sheathing
• UL 90 & UL fire resistance listed
• UL 580/UL 1897 tested
• Florida Product Approval
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
Unless otherwise noted, all testing is for steel only
*Approved for steel and aluminum
36” Coverage (914 mm)
1” (25 mm)
1¼”
(32 mm)
4”
4”
4”
12” (305 mm)
See www.berridge.com for Details and Specifications
38 ¼” Overall Width (972 mm)
Berridge Double-Rib Panel
Prefinished or Acrylic Coated Galvalume
exposed fastener panel for use over solid
sheathing.
36” Coverage (914 mm)
1” (25 mm)
6” (152 mm)
2 ½” (64 mm)
3 ½” (89 mm)
38 ¼” Overall Width (972 mm)
See www.berridge.com for Details and Specifications
• • • • • •
24-gauge steel
Wide, economical 24” coverage
Residential or utility
Traditional appearance
Florida Product Approval
UL 90 & UL fire resistance listed
24” Coverage (610 mm)
½”
(13 mm)
12” (305 mm)
30
See www.berridge.com for Details and Specifications
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
31
EXPOSED FASTENER ROOF & WALL PANELS
Berridge M-Panel
SPECIALTY APPLICATION PRODUCTS
Architectural Privacy Fence
Interlocking panels with fluted texture for large
expansive walls, fascia, or steep mansards. 24 gauge.
• 34 ½” x 10” exposure
• Multi-use panel
Berridge’s Architectural Privacy Fencing utilizes Berridge’s
Spaceframe 24 GA metal studs, track & blocking combined
with a wide selection of factory produced panels, and 16
GA posts.
• Panel interlock for wind resistance*
• Florida Product Approval
* Wind Florida Product Approval is ASTM E330
See www.berridge.com for Details and Specifications
•
•
•
•
•
24-gauge Berridge Spaceframe Components
Sturdy 16-gauge galvanized steel posts
Available in 4’2”, 6’2”, 8’2”, & 10’2” heights
Consult BMC for other fence heights
32 Berridge Kynar 500© Hylar 5000™ Colors
Shown with Berridge Vee-Panel (see page 22).
• 20-Year Paint Finish Limited Warranty
10” Coverage (250 mm)
3/8”
(9 mm)
Berridge Curved Flat Seam
See www.berridge.com for Details and Specifications
Prefinished flat seam metal panel system with concealed
fasteners. Hand curved over solid sheathing. 24 gauge.
Concealed fasteners.
• Permanent: will not rot, fade, crack or split
• Residential or commercial applications
• Level and sloped applications
• 100% recyclable materials
• Fire resistant & termite proof
• Higher wind rating than wood fence
• Interlocking panels with concealed fasteners
• Choose from 5 Berridge 24-gauge panels:
Vee-Panel, Flush Seam, Thin-Line, B-6,
HR-16, or HS-8/HS-12
24 GA Studs
3 1/2” X 1 1/2”
Shown with Berridge Vee-Panel (see page 22).
Berridge Spaceframe
Berridge Spaceframe Building System components are used for
the construction of light-commercial and residential projects.
Double Stud
Assembly
24 GA Track
3 9/16” X 1 9/16”
Berridge Curved Flat Seam is hand-curved over solid sheathing.
PHYSICAL PROPERTIES
16 GA
Cee-Channel
2 1/2” X 8”
8” Coverage (203 mm)
3/16”
32
GROSS PROPERTIES
(in)
(in)
Flange
(in)
Lip
(in)
Weight
(lb/ft)
Ag
(in2)
Ix
(in4)
Sx
(in3)
Iy
(in4)
Sy
(in3)
rx
(in)
ry
(in)
single
stud
0.024
3.5
1.450
---
0.535
0.157
0.252
0.155
0.043
0.039
1.265
0.526
double
stud
0.024
3.5
1.450
---
1.07
0.31491
0.504
0.309
0.149
0.097
1.265
0.689
TORSIONAL PROPERTIES
(5 mm)
See www.berridge.com for Details and Specifications
Thickness Depth
J
(in4)
24 GA Blocking
3 1/2” X 24”
FULL BRACED PROPERTIES & ALLOWABLE STRENGTH
Cw
(in6)
Xo
(in)
Ae
(in2)
Ix
(in4)
Sx
(in3)
Tension
(lbs)
Moment
(lbs•ft)
Shear
(lbs)
single 0.00003023
stud
0.0715
-1.045
0.105
0.252
0.155
3771
309
1171
double 0.00006046
stud
0.14307
0.00
0.21001
0.504
0.309
7542
618
2343
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
33
SPECIALTY APPLICATION PRODUCTS
Berridge Fluted Fascia
FRAMING MEMBERS
A(in2)
(Full)
0.65 lbs
.1900
I (Effective) in
4
Allow. Moment
(in. - kips)
T.I.C.
B.I.C.
T.I.C.
B.I.C.
.0665
.0679
1.61
1.77
VANTAGE POINT: MORE THAN
JUST A NEW ROOF — IT’S A
WHOLE NEW LOOK!
Allow. Shear
(kips)
1 1/4”
Hat Section Purlin
24-Gauge
1 5/8”
3 ¼”
1.01
Thermal & Mechanical Considerations
5 1/16”
2 1/8”
Framing Section
24-Gauge
5/8”
1 ¾”
½”
.065 lbs
.1900
.0759
.0866
1.80
2.26
1.08
0.47 lbs
1 ¾”
.1380
.0530
.0556
1.15
1.21
1.08
¼”
BEFORE
Problem: Flat roofs can sometimes become problematic and unsightly with rooftop
units, mechanical equipment, and pooling water.
1 ¼”
1/2”
7/8”
1 3/8”
0.35 lbs
.1030
.0180
0.180
0.78
0.86
Low Purlin
16-Gauge
5/8”
½”
1.43 lbs
0.422
.151
5.74
2.71
½”
0.82 lbs
0.242
.017
1.51
0.61
2 ½”
1 ½”
2”
0.69 lbs
0.203
.084
.029
1.78
0.56
1.31
2”
Channel & Zee Purlin
4” x 2 1/2”
16-Gauge
4”
1.70 lbs
½”
0.501
1.22
17.7
3.76
2 ½”
2 ½”
3/4”
4”
4”
1.97 lbs
0.557
1.42
18.4
3.84
2”
Channel 6” x 2”
16-Gauge
Channel & Zee Purlin
6” x 2 1/2”
16-Gauge
6”
2.10 lbs
½”
0.621
3.15
30.6
3.45
3/4”
6”
2.41 lbs
0.677
3.61
31.8
3.20
Channel & Zee Purlin
8” x 2 1/2”
16-Gauge
8”
2.50 lbs
½”
0.737
6.43
3/4”
8”
2.82 lbs
0.797
7.09
Notes for 24 GA (0.60 mm) & 16 GA (1.52 mm) Shapes:
1. Values based on 2007 North American Specification for the Design of Cold-Formed Steel Structural members, with
compression flange braced against lateral buckling.
2. Net section properties are used for resisting moment determination and allowable shear loads.
3. Minimum yield strength = 40 ksi for 24 gauge shapes and 50 ksi for 16 gauge shapes (Galvanized steel material).
34
45.0
2.36
2 ½”
2 ½”
8”
The new attic space can be vented with ridge vents or louvers.
Thermal Movement
47.7
2.36
4. E = 29,500 ksi.
5. Values are for upward and downward loads.
6. T.I.C. = Top in Compression
7. B.I.C. = Bottom in Compression
Accommodated at the eaves and with inner-rib expansion joints.
AFTER
Berridge VANTAGE POINT reroofing system combines a new aesthetic
look with simple mechanical attachment over existing flat, built-up roofs
that will last for years to come. VANTAGE POINT is more than just
a patch-up or a re-roof solution; it is a permanent new roof with a new
higher profile which gives your old building a totally new look. The sloped,
light-weight, self-supporting metal panels need no substrate, thus avoiding extra weight and cost. They provide a watertight standing seam that
sheds water in contrast to dated, flat, built-up roofs which are subject to
water pooling and subsequent leakage. Added insulation may be placed
on the existing flat roof.
2
6
5
3/4”
4”
”
2½
2 ½”
2 ½”
3/4”
4”
Cee-Channel
16 Gauge
1
4”
3/4”
4”
Eave Strut
16 Gauge
Zee-Purlin
16 Gauge
Zee-Purlin
16 Gauge
2
3
4
1 1/4”
3 ¼”
1 5/8”
5 1/16”
ZEE-LOCK
The installer orders all necessary coil material & components and all precut retrofit roof system framing members from Berridge.
A Retrofit Design Checklist for Architects
& Designers
1
3
The Berridge Zee-Lock architectural/structural standing seam roof systems
provides superior aesthetic appearance and excellent performance.
7
4
Roof Plane
Economical Installation—
No Tear-Off Required!
Single-Source Convenience
2”
Channel 8” x 2”
16-Gauge
Ventilation
Solution: Berridge Vantage Point Retrofit Roof System provides a totally new design
appearance, hides unsightly mechanical equipment, and offers watertight integrity.
High-Quality Structural/
Architectural Panel
2 ½”
2 ½”
6”
Any existing and new mechanical equipment should be located at ground
level to reduce penetrations.
BASIC VANTAGE POINT
RETROFIT ROOF ASSEMBLY
1 ½”
Channel 4” x 2”
16-Gauge
Mechanical Equipment
3”
Angle 1 1/2” x 2”
16-Gauge
½”
3/4”
A vinyl vapor barrier on the underside of the blanket insulation avoids
condensation from the building penetrating insulation and reaching the
framing system and roof panels.
2”
1 ½”
Vapor Barrier (if required)
0.53
2 3/8”
High Purlin
16-Gauge
The space between the old and new roof allows for low-cost, blanket
insulation to greatly reduce heating and cooling costs.
2”
Furring Channel
24-Gauge
Insulation
3 3/8”
Channel Section
24-Gauge
Roof Design: Low slope to steep mansard profile. Intersecting
planes such as hips, dormers, and valleys should be kept to a
minimum.
Penetrations: Minimize penetrations such as skylights, curbs
for roof-mounted heating or air-conditioning units, etc.
2”
Hat-Channel
24 Gauge
4 1/4”
Open-Track
16 Gauge
5
6
1
16 ga. Cee-Channel. Connect each end w/ (4) #12-14 self-drilling fasteners.
2
16 ga. Eave Strut. Connect to beam w/ (2) #12-14 self-drilling fasteners.
3
16 ga. Continuous 4” x 2-1/2” Zee-Purlin Roof Support.
4
16 ga. Continuous 4” x 2-1/2” Retrofit Sloped Zee-Purlin.
5
24 ga. Hat-Channel. Connect to beam w/ (2) #12-14 self-drilling fasteners
each flange.
6
16 ga. Open-Track x 1’-0” Long. Anchor into wall. Connect to beam w/ (2)
#12-14 self-drilling fasteners each flange.
7
24 ga. 2” Bottom Flange Strapping at Purlin mid-span. Connect to purlin w/
(1) #12-14 self-drilling fastener.
Disclaimer: Project specific engineering required. Consult Engineering Dept.
for pricing. Suggested detail shown above may not be applicable to every project.
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
© Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com
All information subject to change without notice.
All information subject to change without notice.
35
RETROFIT ROOF SYSTEM
24-Gauge & 16-Gauge Components
Weight/LF
For Technical or Sales Assistance:
(800) 669-0009
www.berridge.com
Follow us on:
SPECIFY BERRIDGE
ARCHITECTURAL
METAL PRODUCTS!
www.berridge.com
BMC SAN ANTONIO
Corporate Headquarters
6515 Fratt Road
San Antonio, Texas 78218
(210) 650-3050 local
(210) 650-0379 fax
BMC SEGUIN
Production Facility
2201 Rudeloff Road
Seguin, Texas 78155
(830) 401-5200 local
(830) 303-0530 fax
BMC HOUSTON
Branch Facility
& Technical
1720 Maury Street
Houston, Texas 77026
(713) 223-4971 local
(713) 236-9422 fax
BMC DALLAS
Branch Facility
2015 California Crossing
Dallas, Texas 75220
(972) 506-8496 local
(972) 506-8478 fax
BMC ATLANTA
Branch Facility
319 Lee Industrial Road
Austell, Georgia 30168
(770) 941-5141 local
(770) 941-7344 fax
BMC CHICAGO
Branch Facility
1175 Carolina Road
W. Chicago, Illinois 60185
(630) 231-7495 local
(630) 231-7520 fax
BMC DENVER
Branch Facility
7505 East 41st Avenue
Denver, Colorado 80216
(303) 322-3703 local
(303) 322-3810 fax
BMC PHOENIX
Branch Facility
5717 W. Washington Street
Phoenix, Arizona 85043
(602) 385-1237 local
(210) 650-0379 fax
BMC KANSAS CITY
Branch Facility
1235 Southwest Boulevard
Kansas City, Kansas 66103
(913) 227-0855 local
(210) 650-0379 fax
BMC OKLAHOMA CITY
Branch Facility
1400 Exchange Avenue
Oklahoma City, Oklahoma 73108
(405) 248-7404 local
(210) 650-0379 fax
BERRIDGE CALIFORNIA
SALES CORPORATION*
18732 Corby Avenue
Artesia, California 90701
(562) 402-2081 local
Berridge Manufacturing Company is registered with the AIA Continuing Education System
(AIA/CES) and is committed to developing quality learning activities in accordance with the
CES criteria. Please call Berridge’s Staff Architect at 800-231-8127 to schedule a seminar.
* Berridge California Sales Corporation is a separate entity from Berridge Manufacturing Company.
Berridge Product Catalog - Spring 2016 | 5M | Printed in the USA.
(562) 865-7878 fax