MANUFACTURING COMPANY - Berridge Manufacturing Co.
Transcription
MANUFACTURING COMPANY - Berridge Manufacturing Co.
BERRIDGE MANUFACTURING COMPANY PRODUCT CATALOG FREEDOM OF FORM IN ARCHITECTURAL METAL SYSTEMS Roofs • Walls • Soffits • Mansards • Ceilings Fascia • Facades • Equipment Screens • Restoration Berridge exclusive on-site fabrication technology provides: Custom Contoured Panels Curved Barrel Vault Panels Tapered Panels Compound Curved Panels Long Length Panels For Technical or Sales Assistance: (800) 669-0009 www.berridge.com BERRIDGE ARCHITECTURAL METAL PRODUCTS General Information ........................................................... 3 Green Sustainable Information........................................... 4 Berridge Standard, Metallic & Premium Colors.................. 5 Berridge Finishes & Material Specifications....................... 6 Berridge Testing Summary Chart ...................................... 7 Standing Seam Roof Systems .....................................8-13 Other Roof Systems ...................................................14-15 8 TEE-PANEL 12 CURVED ZEE-LOCK BATTEN SEAM CLASSIC SHINGLE THIN LINE 19 20 25 Berridge’s unique Total Program is a comprehensive approach to supplying superior products and services to customers around the world. The Total Program offers a full range of precision-tolerance portable roll forming machines, painted coil and flat sheet, and over 30 panel styles, all backed by technical and marketing support. The Total Program presents an unparalleled range of products and depth of service that has placed Berridge at the forefront of the architectural metal panel industry. DEEP DECK slitting lines, cut-to-length lines, roll formers, mechanical and hydraulic press-brakes, punch presses, stamping and bending fixtures, and a variety of special dies. This complete line of in-house equipment not only produces top-of-the-line products at the most competitive prices but assures prompt delivery as well. PORTABLE ROLL FORMERS In 1984, Berridge revolutionized the architectural metal panel industry with the introduction of the Model SS-14 Portable Roll Former. This unique machine was designed to roll continuous length, straight, standing seam panels as well as curved panels. Today, over 10 different panels including standing seam, soffit and wall panels may be formed using Berridge portable roll formers. Contact Berridge Sales Department at 1-800-669-0009 for more information about the Model SS-14 and other Berridge portable roll formers. In response to market demand, Berridge developed reconstructive building products for the restoration of historical buildings. A complete line of residential roofing and siding products round out the extensive product line, giving Berridge the industry’s most comprehensive line of architectural metal products. Shop drawings and engineering services for all Berridge products are available upon request. Contact Berridge’s Technical Department at 1-800-231-8127 for pricing or assistance. Architectural details and specifications are available at www.berridge.com. Berridge’s modern, high-production equipment provides customers with low cost, top-quality products. Highly specialized manufacturing equipment converts large, bare Galvalume steel coils into pretreated, prefinished, high quality fabricated architectural sheet metal products. Berridge equipment includes a continuous coil coating line, B-6 PANEL Berridge SS-1421 High Seam Tee-Panel Portable Roll Former can form straight and curved roof panels in continuous lengths to eliminate panel end splices. Machine also curves factory formed snap-on seam caps. Berridge CL-21 Cee-Lock Portable Roll Former forms straight standing seam roof panels in continuous lengths to eliminate panel end splices. Machine also inserts patented vinyl weatherseal in female snap-lock leg. 30 29 32 Since 1970, Berridge Manufacturing Company has provided customers with the industry’s highest quality metal roofing and siding products. For over 45 years, the company has specialized in the research and development of architectural sheet metal products. Many similar products listed in Sweet’s Catalog were originally designed and developed by Berridge Manufacturing Company. EQUIPMENT HS-8 & HS-12 24 28 31 31 S-TILE L-PANEL S-DECK 17 SPANISH TILE FISH SCALE FW-12 27 ZEE-LOCK 16 23 22 26 CEE-LOCK 19 RUSTIC SHAKE 12-13 11 15 BERMUDA PANEL VEE-PANEL FLUSH SEAM HIGH SEAM TEE-PANEL 18 21 HR-16 10 14 18 VICTORIAN SHINGLE Simulated Tile Roof Systems....................................... 16-17 Metal Shingles.............................................................. 18-19 Fascia, Wall & Soffit Panels......................................... 20-27 Exposed Fastener Roof & Wall Panels........................ 28-31 Special Application Products....................................... 32-33 Light-Gauge Framing Components................................... 34 Vantage Point Retrofit Roof System.................................. 35 9 CURVED TEE-PANEL INTRODUCTION & SERVICE M-PANEL 32 33 Above: The unique patented Berridge Vinyl WeatherSeal, which is used on all standing seam and Bermuda Panel systems, provides extra watertight integrity. R-PANEL 2 DOUBLE RIB FLUTED FASCIA CURVED FLAT SEAM ARCH. PRIVACY FENCING Right: Curved Panel Applications are possible with Berridge Portable Roll-Formers. Curved standing seam roof panels are curved at the job site. © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 3 BERRIDGE IS COMMITTED TO “GREEN” SUSTAINABLE COOL METAL ROOFING BERRIDGE MANUFACTURING COMPANY KYNAR 500® HYLAR 5000™ COLOR FINISHES (800) 669-0009 www.berridge.com Energy Star is only valid in the United States. STANDARD COLORS Due to limitations in the printing process, please request actual color chips for accurate color viewing. BERRIDGE METAL ROOFING IS COOL & SUSTAINABLE The high reflectivity, emissivity and solar reflectance index (SRI) of Berridge metal roofing helps mitigate the heat island effect. Berridge’s Kynar 500® & Hylar 5000™ cool metal roof colors are optimal for reducing energy consumption, particularly where cooling loads dominate. For LEED® compliance, reference SRI values for Berridge color finishes below. Berridge Colors Solar Reflectivity % Emissivity PARCHMENT ALMOND AGED BRONZE SHASTA WHITE FOREST GREEN PATINA GREEN SIERRA TAN MEDIUM BRONZE CHARCOAL GREY HEMLOCK GREEN BRISTOL BLUE TERRA-COTTA DARK BRONZE ZINC GREY HARTFORD GREEN ROYAL BLUE COLONIAL RED COPPER BROWN MATTE BLACK TEAL GREEN BURGUNDY DEEP RED SRI Almond 67.10 0.90 82 Aged Bronze 29.66 0.86 30 Antique Copper Cote 29.30 0.85 29 Award Blue 17.20 0.83 12 Bristol Blue 30.30 0.86 31 Buckskin 39.71 0.86 43 Burgundy 30.05 0.85 30 Champagne 34.95 0.85 36 Charcoal Grey 29.64 0.87 30 Colonial Red 33.03 0.85 34 Copper Brown 29.57 0.87 30 Copper-Cote 45.24 0.87 51 Dark Bronze 28.20 0.91 30 Deep Red 38.54 0.84 41 Forest Green 29.08 0.85 29 Hartford Green 28.20 0.90 30 Hemlock Green 30.92 0.83 30 Lead-Cote 32.90 0.90 35 Matte Black 28.70 0.91 30 Medium Bronze 31.39 0.85 32 Natural White 75.93 0.84 93 Parchment 51.72 0.83 58 Patina Green 34.42 0.86 36 Preweathered Galvalume 33.61 0.80 32 Royal Blue 29.90 0.90 32 Shasta White 60.00 0.84 70 Sierra Tan 34.81 0.84 36 Teal Green 28.10 0.89 29 Terra-Cotta 31.66 0.83 31 Zinc-Cote 52.45 0.87 61 Zinc Grey 37.88 0.84 40 Satin Finish Galvalume 74.00 0.14 67 Acrylic Coated Galvalume 67.00 0.06 55 RECYCLED CONTENT OF BERRIDGE METAL Berridge metal products have a high recycled content and are 100% recyclable at the end of their lifespan. Using building products that incorporate recycled materials helps reduce the impacts resulting from the extraction and processing of natural resources. Post-consumer steel recycled content 25.6% Pre-consumer steel recycled content 6.8% TOTAL RECYCLED CONTENT 32.9% LEED® COMPLIANCE SRI Values are provided by Berridge’s paint supplier and may vary slightly. Reference www.berridge.com for the most up-to-date information on Berridge SRI Values. 4 BUCKSKIN In addition to meeting LEED criteria for SS Credit 7.2: Heat Island Effect and for MR Credit 4: Recycled Content, using Berridge metal products can contribute to other LEED points. Reference the Technical Bulletins section at www.berridge.com for more information on Berridge’s compliance with LEED. While every effort has been made to provide accurate information, applicants for LEED Certification should verify compliance with a LEED expert. For more information on LEED 2009 certification visit www.usgbc.org. © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. PREMIUM COLORS METALLIC COLORS Berridge premium colors require a nominal surcharge. NATURAL WHITE Berridge metallic colors are premium finishes which require a nominal surcharge. Due to limitations in the printing process, please request actual color chips for accurate color viewing. AWARD BLUE CHAMPAGNE COPPER-COTETM ANTIQUE COPPER-COTE LEAD-COTETM PREWEATHERED GALVALUME® NATURAL METAL FINISH Berridge Acrylic-Coated Galvalume® is a coated sheet product that combines the corrosion resistance of GALVALUME® steel sheet with a clear, organic resin applied to the top side and bottom side of GALVALUME® substrate. ACRYLIC-COATED GALVALUME® ZINC-COTETM All colors except Award Blue comply with LEED® v3 & Energy Star requirements for steep slope roofs greater than 2:12. Almond & Natural White comply with LEED® v3 requirements for low slope roofs, 2:12 or less. Natural White also complies with Energy Star requirements for low slope roofs, 2:12 or less. 5 © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. KYNAR 500® OR HYLAR 5000TM COLORS & NATURAL METAL FINISHES BERRIDGE TESTING SUMMARY CHART (Steel Substrate, consult Berridge for Aluminum Testing) All Berridge-applied colors are premium fluoropolymer coatings produced with full strength Kynar 500® or Hylar 5000™ resin. Kynar 500® or Hylar 5000™ affords maximum exterior durability due to its outstanding resistance to ultraviolet radiation. Full-strength Kynar 500® or Hylar 5000™ color finishes carry a 20-year warranty against cracking, peeling and fading (not to exceed 5 N.B.S. units). These are the highest quality exterior finishes available! * Metallic Finishes are premium colors which require a nominal surcharge. UL 790 UL 263 Tee Panel Zee-Lock Panel (Double Lock)* • • • • • • • • • • • • • • • • • • • • OTHER ROOF SYSTEMS UL 90 UL 1897 UL 790 UL 263 Bermuda Roof Panel • • • • • • • • • • • • • • • • • • Zee-Lock Panel (Single Lock)* Spanish Tile Roof System Berridge owns and operates its own modern continuous coil coating line in San Antonio, Texas, painting both 48” and 42” wide Galvalume® master coils. S-Tile Roof Panel Batten Seam Roof System Victorian & Classic Shingles COATING SYSTEM Protective Strippable Film (painted material only) ACRYLIC-COATED GALVALUME® Acrylic-Coated Galvalume® (ACG) is a coated sheet product that combines the corrosion resistance of GALVALUME® steel sheet with a clear, acrylic coating that is applied over GALVALUME® substrate. The surface treatment is essentially invisible but it provides excellent characteristics to enhance the performance and applicability of GALVALUME® steel sheet. These enhancements include: good roll-formability without the need for oils, excellent transit and field-storage performance without staining, dramatic decrease in finger printing or foot printing during installation and long term surface brightness when exposed to the environment. It is applied at the mill by roll-coating a uniform, thin film of a water-base acrylic solution onto both surfaces of the sheet. UL 1897 Cee-Lock Panel* Metallic colors are processed and finished on Berridge’s continuous coil-coating line. These proprietary finishes are available for all factory products, flat sheet, and coil. Flat sheets and coils in metallic finishes are available to sheet metal companies for fabrication of special profiles, shapes or flashing. Metallic colors are directional and paint lot sensitive. Large orders should be placed at the same time to avoid mixing paint lots. Berridge Metallic Finishes include: ANTIQUE COPPER-COTE ZINC-COTE™ LEAD-COTE™ UL 90 High Seam Tee Panel BERRIDGE METALLIC FINISHES* COPPER-COTE™ CHAMPAGNE PREWEATHERED GALVALUME® STANDING SEAM ROOF PANELS 0.75 ± 0.05 mil Kynar500® Hylar5000™ top coat 0.20 ± 0.05 mil primer coat 24 gauge or 22 gauge Galvalume or 0.032 or 0.040 Aluminum substrate ® 0.35 ± 0.05 mil total dry film thickness for primer coat (non-metallics only) Beige urethane backer coat (all colors) Notes: 1. Special colors and finishes are available. Please consult Berridge for pricing and delivery. 2. Berridge metallic finishes are premium finishes and require a nominal surcharge. 3. Galvalume® is a registered trademark of BIEC International, Inc. 4. Kynar 500® is a registered trademark of Arkema, Inc. 5. Hylar 5000TM is a registered trademark of Solvay Solexis. Rustic Shake Shingle SHEET METAL MATERIAL A. Prefinished metal shall be Aluminum-Zinc Alloy Coated (AZ-50 Galvalume®) Steel Sheet, 24-Gauge or 22-Gauge*, ASTM 792, Grade 40, yield strength 40 ksi min. or 3105 Alloy Aluminum Sheet 0.032 or 0.040*, ASTM B209, H14 temper, yield strength 21 ksi min. D. Unpainted metal shall be Aluminum-Zinc Alloy Coated (AZ-55 Acrylic Coated Galvalume®) Steel Sheet, 24-Gauge or 22-Gauge*, ASTM 792, Grade 40, yield strength 40 ksi min., with clear acrylic coating on both sides of material. E. Field protection must be provided by the contractor at the job site so stacked or coiled material is not exposed to weather and moisture. B. Finish shall be full strength Kynar 500® or Hylar 5000™ fluoropolymer coating applied by the manufacturer on a continuous coil coating line, with a top side dry film thickness of 0.75 ± 0.05 mil over 0.20 ± 0.05 mil prime coat, to provide a total top side dry film thickness of 0.95 ± 0.10 mil. Bottom side shall be coated with a primer (non-metallics only) and beige urethane coating with a total dry film thickness of 0.35 ± 0.05 mil. Finish shall conform to all tests for adhesion, flexibility, and longevity as specified by the Kynar 500® or Hylar 5000™ finish supplier. F. Flashing may be factory fabricated or field fabricated. Unless otherwise specified all exposed adjacent flashing shall be of the same material and finish as panel system. C. Strippable film shall be applied to the top side of all prefinished metal to protect the finish during fabrication, shipping and field handling. This strippable film MUST be removed immediately before installation. *Not all products and colors are available in 22-Gauge or Aluminum substrate. Consult Berridge for product and color availability in 22-Gauge Galvalume and Aluminum substrate. Note: The rolling process of sheet metal results in inherent surface unevenness referred to as “oil-canning”. This condition is also caused by several factors including thermal expansion and contraction, dark colors, both medium and high-gloss finishes, and uneven substrate. “Oil-canning” in itself is not sufficient cause for material rejection. For complete specifications visit www.berridge.com 6 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • UL ASTM ASTM ASTM ASTM ASTM ASTM ASTM FM 2218 E 1592 E 330 E 2140 E 1646 E 1680 E 331 E 283 4471 • • • • • FL PROD APP MIAMI DADE • • • • • • • FL PROD APP MIAMI DADE • • • • • • • Curved Flat Seam Panel Double Rib Panel • • • • • • • FASCIA, WALL & SOFFIT PANELS UL 90 UL 790 "R" Panel "M" Panel Deep Deck Panel S-Deck UL 1897 • • • • • UL 263 • • • • • • HR-16 Panel HS Wall Panels FW-12 & FW-1025 Panels Thin Line Panel • • • • • • • UL ASTM ASTM ASTM ASTM ASTM ASTM ASTM FM 2218 E 1592 E 330 E 2140 E 1646 E 1680 E 331 E 283 4471 Flush Seam Panel L-Panel SPECIFICATIONS FOR ALL 24 & 22-GAUGE GALVALUME* & 0.032 & 0.040 ALUMINUM* BERRIDGE PRODUCTS • UL ASTM ASTM ASTM ASTM ASTM ASTM ASTM FM 2218 E 1592 E 330 E 2140 E 1646 E 1680 E 331 E 283 4471 • FL PROD APP • • • • • • • • • • • • MIAMI DADE • • • Vee-Panel B-6 Panel • Fluted Fascia Panel • For actual test results, technical questions, fastener types, fastener spacing, or job-specific engineering, please contact Berridge’s Technical Department at (800) 669-0009. Updates and additional testing are added on a continual basis. Consult Technical Dept. for the latest updates. *Use continuous ribs for ASTM E 1646, ASTM E 1680, ASTM E 331, and ASTM E283 compliance. UL 90 - Uplift Tests of Roof System UL 1897 - Uplift Tests of Roof System UL 790 - Fire Tests of Roof System UL 263 - Fire Tests of Construction and Materials UL 2218 - Impact Resistance of Prepared Roof Covering Materials ASTM E-1592 - Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference ASTM E-330 - Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference ASTM E-2140 - Water Penetration of Metal Roof Panel Systems by Static Water Pressure Head ASTM E-1646 - Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference ASTM E-1680 - Rate of Air Leakage Through Exterior Metal Roof Panel Systems ASTM E-331 - Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference ASTM E-283 - Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen FM 4471 - This standard states Approval requirements for Class 1 Panel Roofs. A Class 1 Panel Roof meets the criteria of this standard for fire, wind, foot traffic & hail damage resistance. Florida Product Approval - Standard of practice for product evaluations and consistency of enforcement for the state of Florida. Miami-Dade Approval - Established with its main goal to allow new and innovated ideas to be developed into useful, practical, lasting and safe products for use in High Velocity Hurricane Zones. © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 7 STANDING SEAM METAL ROOF SYSTEMS Berridge Curved, Compound Curved & Tapered Tee-Panel Metal Standing Seam with exclusive patented vinyl weatherseal as an integral part of Snap-On Seam. For residential or commercial construction with solid sheathing. Metal Standing Seam with exclusive patented vinyl weatherseal as an integral part of Snap-On Seam. Concave, convex, or compound curved corners and domed roof construction with solid sheathing. • Available in 24 gauge steel & 0.032 aluminum • Extruded vinyl weatherseal as integral part of Snap-on seam cap • Concealed fasteners • UL 580 tested • UL 90 wind uplift* • UL fire resistance listed • ASTM air & water resistance tested • Florida Product Approval • May be site-formed in continuous lengths with Berridge SS-14 portable roll former • Convex (min 4’) & concave (min 6’) curving with Berridge SS-14 portable 1” (25 mm) roll former Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum 8 STANDING SEAM METAL ROOF SYSTEMS Berridge Tee-Panel 12 ¾” Coverage (324 mm) Snap-On Seam (with Vinyl Weatherseal) Tee-Panel • Available in 24 gauge steel & 0.032 aluminum • Extruded vinyl weatherseal as integral part of Snap-on seam cap • Concealed fasteners • UL 580 tested • UL 90 wind uplift* • UL fire resistance listed • ASTM air & water resistance tested • Florida Product Approval • Site-formed & curved with Berridge SS-14 portable roll former (Use SL1” (25 mm) 24 for tapered & SL-1 for compound curved panels) Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum 12 ¾” Coverage (324 mm) Width at eave varies on tapered Tee-Panel Snap-On Seam (with Vinyl Weatherseal) Tee-Panel See www.berridge.com for Details and Specifications Vinyl Weatherseal: US Patent No. 4641475 See www.berridge.com for Details and Specifications Vinyl Weatherseal: US Patent No. 4641475 © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 9 STANDING SEAM METAL ROOF SYSTEMS Berridge Cee-Lock Panel Metal Standing Seam with exclusive patented vinyl weatherseal as an integral part of Snap-On Seam. For residential or commercial construction with solid sheathing. Metal Standing Seam with exclusive patented vinyl weatherseal as an integral part of Snap-Lock Seam. Residential and commercial construction with solid sheathing. • Available in 22 & 24 gauge steel & 0.032 aluminum • Extruded vinyl weatherseal as integral part of Snap-on seam cap • Concealed fasteners • UL 90 wind uplift & UL fire resistance listed • ASTM air & water resistance tested • Florida Product Approval • May be site-formed in continuous lengths with Berridge SS-1421 portable roll former • Consult Berridge for minimum radius. (Striated profile is standard) 18 ¼” Coverage (464 mm) Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum 1” or 1 ½” (25 mm or 38 mm) Snap-On Seam (with Vinyl Weatherseal) High Seam Tee-Panel See www.berridge.com for Details and Specifications Vinyl Weatherseal: US Patent No. 4641475 10 • Available in 24 & 22 gauge steel & 0.032 aluminum • Extruded vinyl weatherseal (optional) • Concealed fasteners • Integral snap-lock seam • Striated profile is available • UL 580 tested* • UL 90 wind uplift* • UL fire resistance listed • UL 1897 tested* • ASTM air & water resistance tested 1 ½” • ASTM E-1592 tested (38 mm) • Florida Product Approval* • Miami-Dade approved • ICC-ES Report ESR-3486 • May be site-formed in continuous lengths with Berridge CL-21 portable roll former Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum Cee-Lock Panel STANDING SEAM METAL ROOF SYSTEMS Berridge High Seam Tee-Panel 16 ½” Coverage (419 mm) See www.berridge.com for Details and Specifications Vinyl Weatherseal (Optional) is required for Watertight Warranties. Cee-Lock Clip or Continuous Cee-Rib (Required for WTW) Vinyl Weatherseal: US Patent No. 4641475 © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. Optional panel striations 11 STANDING SEAM METAL ROOF SYSTEMS Berridge Zee-Lock Double-Lock Architectural/Structural standing seam roof system for use over open purlin framing or solid sheathing. Straight or curved applications. • • • • • • • • • • • • • • • • Available in 24 & 22 gauge steel & 0.032 aluminum Extruded vinyl weatherseal on continuous rib (Optional) Mechanically seamed sidelap 2” high standing seam sidelap Optional striated profile available UL 90 wind uplift UL fire resistance listed ASTM air & water resistance tested ASTM E-1592 tested UL 580 tested* UL 1897 tested* ASTM E-2140 tested Corps of Engineers CEGS 07416 approved Florida Product Approval ICC-ES Report ESR-3486 Continuous lengths when site-formed with SP-21 portable roll-former • Site-curved with ZC-21 curving machine Unless otherwise noted, all testing is for steel only Architectural/Structural standing seam roof system for use over open purlin framing or solid sheathing. Berridge Curved Zee-Lock Berridge Single Lock Zee-Lock can be curved to a minimum radius of 20’ using the Berridge ZC-21 Curver machine. Curving of the panel to be done on-site. 2” 51 mm 11/16” 2” 51 mm ¼” 16” Coverage (406 mm) 11/16” 16” Coverage (406 mm) *Approved for steel and aluminum ¼” 1 3/16” ZEE-LOCK PANEL CROSS-SECTION See www.berridge.com for Details and Specifications 1 3/16” • Available in 22 & 24 gauge steel & 0.032 aluminum • Mechanically double-locked sidelap • 2” high standing seam sidelap • Optional striated profile available • UL 90 wind uplift • UL fire resistance listed • ASTM air & water resistance tested • ASTM E-1592 tested • UL 580 tested* • UL 1897 tested* • ASTM E-2140 tested • FMRC Approved & 1-150 SH rated • Corps. of Engineering CEGS approved • ICC-ES Report ESR-3486 • Florida Product Approval • Miami-Dade Approval • Continuous lengths when site-formed with SP-21 portable roll-former Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum ZEE-LOCK PANEL CROSS-SECTION See www.berridge.com for Details and Specifications The 180-degree mechanically seamed Zee-Lock seam is not available with vinyl weatherseal. Optional Extruded Vinyl Weatherseal (*US Patent No. 5134825) Note: Vinyl Weatherseal required for open framing and curved applications as well as for Watertight Warranties. Continuous Zee-Rib Continuous Zee-Rib or Zee-Clip (Required for WTW) ZEE-LOCK DOUBLE-LOCK PANEL ASSEMBLY OPTIONAL SNAP-ON BATTEN CAP ZEE-LOCK PANEL ASSEMBLY The Berridge Zee-Lock Double-Lock Seamer double locks the sidelap seam in a single pass. Not available for use with vinyl weatherseal. The Berridge Zee-Lock Seamer locks the sidelap seam in a single pass. Use continuous Zee-Rib with vinyl for best performance. Optional panel striations ZEE-LOCK SECTION PROPERTIES BASED ON 24 GA 40 K.S.I. ZEE-LOCK IX (in4/ft) MA (ft.lbs/ft) VA (lbs/ft) Positive Bending 0.1525 184.65 Negative Bending 0.1031 161.33 ZEE-LOCK SECTION PROPERTIES BASED ON 24 GA 40 K.S.I. ZEE-LOCK IX (in4/ft) MA (ft.lbs/ft) VA (lbs/ft) 990 Positive Bending 0.1525 184.65 990 990 Negative Bending 0.1031 161.33 990 NOTES: Zee-Lock Panel with continuous 24 GA Zee-Rib. Values based on 1996 edition of AISI and good engineering practice. 12 STANDING SEAM METAL ROOF SYSTEMS Berridge Zee-Lock NOTES: Zee-Lock Panel with continuous 24 GA Zee-Rib. Values based on 1996 edition of AISI and good engineering practice. © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 13 OTHER ROOF SYSTEMS Berridge Bermuda Panel Two-part system utilizes Deep Vee Panel and square Snap-On battens for more visible seams. May be installed over open framing or solid sheathing. Traditional Bermuda roof design. Continuous length panels for roof, fascia or mansard. • • • • • • • • • • • • • • Available in 24 gauge steel Concealed fasteners Spans over open purlins UL 90 wind uplift & UL fire resistance listed Florida Product Approval May be site-formed in continuous lengths with Berridge BP-21 portable roll-former Available in 24 gauge steel Concealed fasteners Optional vinyl weatherseal Strong horizontal lines & stepped appearance Optional wood grain embossed texture UL 90 wind uplift & UL fire resistance listed Florida Product Approval May be site-formed in continuous lengths using Berridge BP-14 portable roll former 16” Coverage (406 mm) 2” 14 11” Coverage (279 mm) 1” (25 mm) Snap-On Batten Cap 1 ¾” (45 mm) Deep-Vee Panel OTHER ROOF SYSTEMS Berridge Batten Seam Panel See www.berridge.com for Details and Specifications See www.berridge.com for Details and Specifications Vinyl Weatherseal: US Patent No. 5134825 © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 15 SIMULATED TILE ROOF SYSTEMS Berridge S-Tile Prefinished metal Spanish Tile System used with Deep-Vee Panel. Eliminates the need for solid sheathing and furring strips. Prefinished metal S-Tile panels with a clean, crisp simulated tile appearance. • • • • • • • • Available in 24 gauge steel Concealed fasteners Stronger and lighter than clay tiles Available in all standard Berridge Kynar 500® or Hylar 5000TM finishes May be installed over open framework UL 580/UL 1897 tested UL fire resistance listed Florida Product Approval 8” Width (203 mm) 9” Width (227 mm) Spanish Tile Deep-Vee Panel 2” (51 mm) 1 ½” (38 mm) • • • • • • • • • • SIMULATED TILE ROOF SYSTEMS Berridge Spanish Tile Available in 24 gauge steel Exposed fasteners Light weight: only 1.2 lbs/ft2 Available in all standard Berridge Kynar 500® or Hylar 5000TM finishes UL 580/UL 1897 tested Florida Product Approval Miami-Dade approved UL fire resistance listed ASTM E-1592 tested Continuous length eave-to-ridge panels up to 40’ long for fast installation without panel endlaps 32 11/16“ Coverage (830 mm) 1 ½” (38 mm) 16” Coverage (406 mm) 3’ min - 40’ max 14” (350 mm) 14” (350 mm) 14” (350 mm) Eave Closure See www.berridge.com for Details and Specifications See www.berridge.com for Details and Specifications Colors can be mixed. Shown with custom color palette above. 16 © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 17 METAL SHINGLES Berridge Rustic Shake Shingles Prefinished Kynar 500®, Hylar 5000TM, or Acrylic Coated Galvalume® traditional shingle for restoration, residential, & commercial construction with solid sheathing for roofs or walls. Concealed Fasteners. Florida & Miami-Dade approved. 24 gauge steel. UL 580/UL 1897 tested. Prefinished heavy-gauge shingles with concealed fasteners for residential or commercial construction with solid sheathing. 24 gauge steel. 12” Coverage (305 mm) 12” Coverage (305 mm) 9” Coverage (229 mm) 24” Coverage (610 mm) Berridge Classic Shingles Berridge Fish Scale Shingles Prefinished Kynar 500®, Hylar 5000TM, or Acrylic Coated Galvalume® traditional shingle for restoration, residential, & commercial construction with solid sheathing for roofs or walls. Concealed Fasteners. Florida & Miami-Dade approved. 24 gauge steel. UL 580/UL 1897 tested. Historical product for gable, sidewall, steep mansard, or fascia applications (80°+) with solid sheathing. 24 gauge steel. 8 ½” (216 mm) 12” Coverage (305 mm) 9” Coverage (229 mm) 18 11 ½” Coverage (292 mm) © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 19 METAL SHINGLES Berridge Victorian Shingles FASCIA, WALL & SOFFIT PANELS Berridge HR-16 Prefinished horizontal or vertical wall panel. Versatile and maintenance-free. Prefinished horizontal or vertical metal wall panel. • Available in 24 & 22 gauge steel or 0.032 & 0.040 aluminum • Standard with stucco embossing • Concealed fasteners • Multi-purpose wall panel • May be used horizontally or vertically • May be used for soffit applications • Wide rib appearance • Interlocks with HR-16 wall panel • Factory formed to 40’ max • ASTM air & water resistance tested • ASTM E-1592 tested* • Florida Product Approval* • Consult Berridge for smooth finish availability • May be used over solid sheathing or open framing • Available in 24 & 22 gauge steel or 0.032 & 0.040 aluminum • Standard smooth finish • Concealed fasteners • Multi-purpose wall panel • May be used horizontally or vertically • Interlocks with HS-8 & HS-12 • Narrow-rib appearance • Florida Product Approval* • Miami-Dade Approved • ASTM air & water resistance tested • ASTM E-1592 tested* • May be used over solid sheathing or open framing • Factory formed to 40’ max Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum 8” Coverage (203 mm) Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum 5 5/ 8” (143 mm) 7/ 8” (22 mm) HS-8 Wall Panel 16” Coverage (406 mm) 4” (102 mm) 12” Coverage (305 mm) 9 5/ 8” (244 mm) 7/ 8” (22 mm) HS-12 Wall Panel 7/ 8” (22 mm) 1 1/ 8” (29 mm) 1 5/ 8” (41 mm) HR-16 Wall Panel 20 See www.berridge.com for Details and Specifications See www.berridge.com for Details and Specifications Detail of HS-12 & HS-8 Panel Interlock Detail of HR-16 Panel Interlock © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 21 FASCIA, WALL & SOFFIT PANELS Berridge HS-8 & HS-12 FASCIA, WALL & SOFFIT PANELS Berridge FW-1025 & FW-12 Panel Wall, soffit and facade system versatile and maintenance free prefinished metal wall panels for open spans Wall, Liner, or Soffit Panels. Versatile, maintenancefree, prefinished metal wall panels for open spans. • • • • • • • • Available in 24 & 22 gauge steel or 0.032 & 0.040 aluminum • Concealed fasteners • Optional vee-grooves • Seam lock feature (optional) • Striated profile (optional) • Optional stucco embossed texture • Panel may be vented • Soffit and vertical wall applications • Open framing or solid sheathing • ASTM air & water resistance tested • ASTM E-1592* • Florida Product Approval* • Miami-Dade Approved Available in 24 & 22 gauge steel Concealed fasteners Vee-groove appearance Optional wood grain embossed texture Panel may be vented Soffit and vertical wall applications Open framing or solid sheathing FASCIA, WALL & SOFFIT PANELS Berridge Vee-Panel Optional seam lock feature. Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum 10 1/4” Coverage (260 mm) 1 1/2” (38 mm) Berridge Vee-Panel, vertical wall application. With a 12” coverage, Berridge FW-12 panel is ideal for large soffit and ceiling applications. 3.4” (86 mm) 12” Coverage (305 mm) 1 1/2” (38 mm) 4” (102 mm) 12 3/4” Coverage (324 mm) Available without grooves. 4 1/4” (108 mm) Available with striations. 3/8” Berridge Vee-Panel is great for walls, fascia, and soffit applications. (10 mm) Vented Vee-Panel Notes: Panel provides 6.46 square inches of Net Free Vent Area (NFVA) per linear foot of panel. Berridge Manufacturing Company does not recommend vented products in applications subject to aggressive atmospheres, marine environments, or high humidity due to the corrosive nature of these environments on raw edges of steel. Berridge Vee-Panel can be vented for soffit applications. 22 See www.berridge.com for Details and Specifications Berridge FW-1025 & FW-12 are multipurpose wall and soffit panels. Available with vents. Vented FW-1025 & FW-12 Notes: Panel provides 7.79 square inches of Net Free Vent Area (NFVA) per linear foot of panel. Berridge does not recommend vented products in applications subject to aggressive atmospheres, marine environments, or high humidity. See www.berridge.com for Details and Specifications © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 23 FASCIA, WALL & SOFFIT PANELS FASCIA, WALL & SOFFIT PANELS Berridge B-6 Panel Corrugated metal wall, liner, or soffit panels for open spans or solid sheathing. Berridge L-Panel is an economical and versatile panel for fascia, soffit, liner, and ceiling applications. Available with 2 grooves, 1 groove or no grooves as shown above. • 24 gauge steel • Concealed fasteners • Use vertically for fascia, facade, or siding • Self-venting • Open framing or solid sheathing • Available in 24 & 22 gauge steel & 0.032 aluminum (Consult BMC for 22 gauge) • Concealed fasteners • Optional vee-grooves • Optional stucco embossed texture • Panel may be vented • Open framing or solid sheathing • ASTM E-1592 • Miami-Dade Approved • May be site-formed using Berridge FP-16 portable roll former Berridge B-6 Panel is a great option for interior ceiling and wall applications. 11 5/8” Coverage (290 mm) 1” (25 mm) 6” Coverage (152 mm) 5/ 8” (16 mm) 3 7/8” (98 mm) Berridge L-Panel is a great soffit panel and can be site-formed with the FP-16 portable roll former. Available with one groove. See www.berridge.com for Details and Specifications Berridge B-6 Panel is a good option for fascia and soffit applications and provides a sleek, corrugated appearance. Available smooth without grooves. Berridge L-Panel can be vented for soffit applications. Vented L-Panel Notes: Panel provides 5.19 square inches of Net Free Vent Area (NFVA) per linear foot of panel. Berridge Manufacturing Company does not recommend this product in applications subject to aggressive atmospheres, marine environments, or high humidity due to the corrosive nature of these environments on raw edges of steel. See www.berridge.com for Details and Specifications 24 Berridge B-6 Panel can be used vertically on curved wall applications. Berridge B-6 Panel can be used vertically on curved wall applications. © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 25 FASCIA, WALL & SOFFIT PANELS Berridge Thin-Line With rigid embossed texture for soft, uniform reflectivity. Prefinished fascia or soffit panel for open spans to provide flat appearance. Versatile, maintenance-free, prefinished metal fascia, facade, wall or soffit panels for open spans. Berridge Flush Seam’s embossed texture make it a good option for large wall expanses. • • • • • • • • • 24 gauge steel Concealed fasteners Stucco embossed texture Optional wood grain texture Use vertically for facade or wall Self-venting Open framing or solid sheathing Florida Product Approval ASTM air resistance tested ½” (13 mm) See www.berridge.com for Details and Specifications 26 24 gauge steel Concealed fasteners Channel drain interlock Narrow panel with smooth appearance Optional wood grain or stucco embossed texture • Use vertically for fascia or wall • Open framing or solid sheathing • Florida Product Approval 3 7/8” Coverage (98 mm) Berridge Flush Seam can be used vertically on curved wall applications. Panel does not curve. Berridge Flush Seam is a multipurpose wall, soffit, and liner panel and can also be used in interior ceiling applications as shown above. • • • • • Picture features close up of optional wood grain texture. 3 5/8” Coverage (91 mm) Berridge Thin Line is a multipurpose wall,soffit, liner, ceiling and fascia panel. Berridge Thin Line panel provides smooth, narrow lines. 3/8” (9 mm) See www.berridge.com for Details and Specifications Picture features optional wood grain texture. See page 26 for close up view. © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 27 FASCIA, WALL & SOFFIT PANELS Berridge Flush Seam EXPOSED FASTENER ROOF & WALL PANELS Berridge Deep-Deck Corrugated structural metal sheathing. S-Deck may be curved for covered walkways, shelter covers, etc. Prefinished corrugated 7.2” roof or wall panel for use on open framing or solid sheathing. • Available in 24 & 22 gauge steel or 0.032 & 0.040 aluminum • Vertical and horizontal applications • 32” panels can be factory curved • Minimum 5’ radius for curved panels • ASTM E-1592 tested* • Florida Product Approval* • UL fire resistance listed • Multi-use panel: roof, wall, or sheathing EXPOSED FASTENER ROOF & WALL PANELS Berridge S-Deck 36” Coverage (914 mm) 1 ½” (38 mm) • Available in 24 & 22 gauge steel or 0.032 & 0.040 aluminum • Wide, economical 36” coverage • Vertical & horizontal applications • Structural properties • Purlin bearing leg standard • Multi-use panel: roof, wall, or deck • ASTM air & water resistance tested • ASTM E-1592 tested* • Florida Product Approval* • UL 90 & UL fire resistance listed Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum 2” (51 mm) 7.2” (183 mm) See www.berridge.com for Details and Specifications Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum Nominal 32” Coverage (813 mm) 7/8” (22 mm) 2.67” (68 mm) Nominal 34.67” Coverage (880 mm) 7/8” 2.67” (68 mm) (22 mm) Curved S-Deck Notes: Curved S-Deck is available in 32” exposure panels only. Berridge recommends lapping two corrugations on panel side laps when using curved S-Deck. Exposure will be 29.33” with two laps or 32” with one lap. See www.berridge.com for Details and Specifications 28 © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 29 EXPOSED FASTENER ROOF & WALL PANELS Berridge R-Panel Prefinished or Acrylic Coated Galvalume, wall, soffit, fascia, mansard, liner, or equipment screen panel Prefinished or Acrylic Coated Galvalume, wall, soffit, fascia, mansard, liner, or equipment screen panel • Available in 24 & 22 gauge steel & 0.032 aluminum • Wide, economical 36” coverage • Vertical & horizontal applications • Open framing or solid sheathing • UL 90 & UL fire resistance listed • Florida Product Approval • Available in 24 & 22 gauge steel & 0.032 aluminum • Wide, economical 36” coverage • Vertical & horizontal applications • Open framing or solid sheathing • UL 90 & UL fire resistance listed • UL 580/UL 1897 tested • Florida Product Approval Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum Unless otherwise noted, all testing is for steel only *Approved for steel and aluminum 36” Coverage (914 mm) 1” (25 mm) 1¼” (32 mm) 4” 4” 4” 12” (305 mm) See www.berridge.com for Details and Specifications 38 ¼” Overall Width (972 mm) Berridge Double-Rib Panel Prefinished or Acrylic Coated Galvalume exposed fastener panel for use over solid sheathing. 36” Coverage (914 mm) 1” (25 mm) 6” (152 mm) 2 ½” (64 mm) 3 ½” (89 mm) 38 ¼” Overall Width (972 mm) See www.berridge.com for Details and Specifications • • • • • • 24-gauge steel Wide, economical 24” coverage Residential or utility Traditional appearance Florida Product Approval UL 90 & UL fire resistance listed 24” Coverage (610 mm) ½” (13 mm) 12” (305 mm) 30 See www.berridge.com for Details and Specifications © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 31 EXPOSED FASTENER ROOF & WALL PANELS Berridge M-Panel SPECIALTY APPLICATION PRODUCTS Architectural Privacy Fence Interlocking panels with fluted texture for large expansive walls, fascia, or steep mansards. 24 gauge. • 34 ½” x 10” exposure • Multi-use panel Berridge’s Architectural Privacy Fencing utilizes Berridge’s Spaceframe 24 GA metal studs, track & blocking combined with a wide selection of factory produced panels, and 16 GA posts. • Panel interlock for wind resistance* • Florida Product Approval * Wind Florida Product Approval is ASTM E330 See www.berridge.com for Details and Specifications • • • • • 24-gauge Berridge Spaceframe Components Sturdy 16-gauge galvanized steel posts Available in 4’2”, 6’2”, 8’2”, & 10’2” heights Consult BMC for other fence heights 32 Berridge Kynar 500© Hylar 5000™ Colors Shown with Berridge Vee-Panel (see page 22). • 20-Year Paint Finish Limited Warranty 10” Coverage (250 mm) 3/8” (9 mm) Berridge Curved Flat Seam See www.berridge.com for Details and Specifications Prefinished flat seam metal panel system with concealed fasteners. Hand curved over solid sheathing. 24 gauge. Concealed fasteners. • Permanent: will not rot, fade, crack or split • Residential or commercial applications • Level and sloped applications • 100% recyclable materials • Fire resistant & termite proof • Higher wind rating than wood fence • Interlocking panels with concealed fasteners • Choose from 5 Berridge 24-gauge panels: Vee-Panel, Flush Seam, Thin-Line, B-6, HR-16, or HS-8/HS-12 24 GA Studs 3 1/2” X 1 1/2” Shown with Berridge Vee-Panel (see page 22). Berridge Spaceframe Berridge Spaceframe Building System components are used for the construction of light-commercial and residential projects. Double Stud Assembly 24 GA Track 3 9/16” X 1 9/16” Berridge Curved Flat Seam is hand-curved over solid sheathing. PHYSICAL PROPERTIES 16 GA Cee-Channel 2 1/2” X 8” 8” Coverage (203 mm) 3/16” 32 GROSS PROPERTIES (in) (in) Flange (in) Lip (in) Weight (lb/ft) Ag (in2) Ix (in4) Sx (in3) Iy (in4) Sy (in3) rx (in) ry (in) single stud 0.024 3.5 1.450 --- 0.535 0.157 0.252 0.155 0.043 0.039 1.265 0.526 double stud 0.024 3.5 1.450 --- 1.07 0.31491 0.504 0.309 0.149 0.097 1.265 0.689 TORSIONAL PROPERTIES (5 mm) See www.berridge.com for Details and Specifications Thickness Depth J (in4) 24 GA Blocking 3 1/2” X 24” FULL BRACED PROPERTIES & ALLOWABLE STRENGTH Cw (in6) Xo (in) Ae (in2) Ix (in4) Sx (in3) Tension (lbs) Moment (lbs•ft) Shear (lbs) single 0.00003023 stud 0.0715 -1.045 0.105 0.252 0.155 3771 309 1171 double 0.00006046 stud 0.14307 0.00 0.21001 0.504 0.309 7542 618 2343 © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 33 SPECIALTY APPLICATION PRODUCTS Berridge Fluted Fascia FRAMING MEMBERS A(in2) (Full) 0.65 lbs .1900 I (Effective) in 4 Allow. Moment (in. - kips) T.I.C. B.I.C. T.I.C. B.I.C. .0665 .0679 1.61 1.77 VANTAGE POINT: MORE THAN JUST A NEW ROOF — IT’S A WHOLE NEW LOOK! Allow. Shear (kips) 1 1/4” Hat Section Purlin 24-Gauge 1 5/8” 3 ¼” 1.01 Thermal & Mechanical Considerations 5 1/16” 2 1/8” Framing Section 24-Gauge 5/8” 1 ¾” ½” .065 lbs .1900 .0759 .0866 1.80 2.26 1.08 0.47 lbs 1 ¾” .1380 .0530 .0556 1.15 1.21 1.08 ¼” BEFORE Problem: Flat roofs can sometimes become problematic and unsightly with rooftop units, mechanical equipment, and pooling water. 1 ¼” 1/2” 7/8” 1 3/8” 0.35 lbs .1030 .0180 0.180 0.78 0.86 Low Purlin 16-Gauge 5/8” ½” 1.43 lbs 0.422 .151 5.74 2.71 ½” 0.82 lbs 0.242 .017 1.51 0.61 2 ½” 1 ½” 2” 0.69 lbs 0.203 .084 .029 1.78 0.56 1.31 2” Channel & Zee Purlin 4” x 2 1/2” 16-Gauge 4” 1.70 lbs ½” 0.501 1.22 17.7 3.76 2 ½” 2 ½” 3/4” 4” 4” 1.97 lbs 0.557 1.42 18.4 3.84 2” Channel 6” x 2” 16-Gauge Channel & Zee Purlin 6” x 2 1/2” 16-Gauge 6” 2.10 lbs ½” 0.621 3.15 30.6 3.45 3/4” 6” 2.41 lbs 0.677 3.61 31.8 3.20 Channel & Zee Purlin 8” x 2 1/2” 16-Gauge 8” 2.50 lbs ½” 0.737 6.43 3/4” 8” 2.82 lbs 0.797 7.09 Notes for 24 GA (0.60 mm) & 16 GA (1.52 mm) Shapes: 1. Values based on 2007 North American Specification for the Design of Cold-Formed Steel Structural members, with compression flange braced against lateral buckling. 2. Net section properties are used for resisting moment determination and allowable shear loads. 3. Minimum yield strength = 40 ksi for 24 gauge shapes and 50 ksi for 16 gauge shapes (Galvanized steel material). 34 45.0 2.36 2 ½” 2 ½” 8” The new attic space can be vented with ridge vents or louvers. Thermal Movement 47.7 2.36 4. E = 29,500 ksi. 5. Values are for upward and downward loads. 6. T.I.C. = Top in Compression 7. B.I.C. = Bottom in Compression Accommodated at the eaves and with inner-rib expansion joints. AFTER Berridge VANTAGE POINT reroofing system combines a new aesthetic look with simple mechanical attachment over existing flat, built-up roofs that will last for years to come. VANTAGE POINT is more than just a patch-up or a re-roof solution; it is a permanent new roof with a new higher profile which gives your old building a totally new look. The sloped, light-weight, self-supporting metal panels need no substrate, thus avoiding extra weight and cost. They provide a watertight standing seam that sheds water in contrast to dated, flat, built-up roofs which are subject to water pooling and subsequent leakage. Added insulation may be placed on the existing flat roof. 2 6 5 3/4” 4” ” 2½ 2 ½” 2 ½” 3/4” 4” Cee-Channel 16 Gauge 1 4” 3/4” 4” Eave Strut 16 Gauge Zee-Purlin 16 Gauge Zee-Purlin 16 Gauge 2 3 4 1 1/4” 3 ¼” 1 5/8” 5 1/16” ZEE-LOCK The installer orders all necessary coil material & components and all precut retrofit roof system framing members from Berridge. A Retrofit Design Checklist for Architects & Designers 1 3 The Berridge Zee-Lock architectural/structural standing seam roof systems provides superior aesthetic appearance and excellent performance. 7 4 Roof Plane Economical Installation— No Tear-Off Required! Single-Source Convenience 2” Channel 8” x 2” 16-Gauge Ventilation Solution: Berridge Vantage Point Retrofit Roof System provides a totally new design appearance, hides unsightly mechanical equipment, and offers watertight integrity. High-Quality Structural/ Architectural Panel 2 ½” 2 ½” 6” Any existing and new mechanical equipment should be located at ground level to reduce penetrations. BASIC VANTAGE POINT RETROFIT ROOF ASSEMBLY 1 ½” Channel 4” x 2” 16-Gauge Mechanical Equipment 3” Angle 1 1/2” x 2” 16-Gauge ½” 3/4” A vinyl vapor barrier on the underside of the blanket insulation avoids condensation from the building penetrating insulation and reaching the framing system and roof panels. 2” 1 ½” Vapor Barrier (if required) 0.53 2 3/8” High Purlin 16-Gauge The space between the old and new roof allows for low-cost, blanket insulation to greatly reduce heating and cooling costs. 2” Furring Channel 24-Gauge Insulation 3 3/8” Channel Section 24-Gauge Roof Design: Low slope to steep mansard profile. Intersecting planes such as hips, dormers, and valleys should be kept to a minimum. Penetrations: Minimize penetrations such as skylights, curbs for roof-mounted heating or air-conditioning units, etc. 2” Hat-Channel 24 Gauge 4 1/4” Open-Track 16 Gauge 5 6 1 16 ga. Cee-Channel. Connect each end w/ (4) #12-14 self-drilling fasteners. 2 16 ga. Eave Strut. Connect to beam w/ (2) #12-14 self-drilling fasteners. 3 16 ga. Continuous 4” x 2-1/2” Zee-Purlin Roof Support. 4 16 ga. Continuous 4” x 2-1/2” Retrofit Sloped Zee-Purlin. 5 24 ga. Hat-Channel. Connect to beam w/ (2) #12-14 self-drilling fasteners each flange. 6 16 ga. Open-Track x 1’-0” Long. Anchor into wall. Connect to beam w/ (2) #12-14 self-drilling fasteners each flange. 7 24 ga. 2” Bottom Flange Strapping at Purlin mid-span. Connect to purlin w/ (1) #12-14 self-drilling fastener. Disclaimer: Project specific engineering required. Consult Engineering Dept. for pricing. Suggested detail shown above may not be applicable to every project. © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com © Spring 2016 Berridge Manufacturing Company • 800-669-0009 • www.berridge.com All information subject to change without notice. All information subject to change without notice. 35 RETROFIT ROOF SYSTEM 24-Gauge & 16-Gauge Components Weight/LF For Technical or Sales Assistance: (800) 669-0009 www.berridge.com Follow us on: SPECIFY BERRIDGE ARCHITECTURAL METAL PRODUCTS! www.berridge.com BMC SAN ANTONIO Corporate Headquarters 6515 Fratt Road San Antonio, Texas 78218 (210) 650-3050 local (210) 650-0379 fax BMC SEGUIN Production Facility 2201 Rudeloff Road Seguin, Texas 78155 (830) 401-5200 local (830) 303-0530 fax BMC HOUSTON Branch Facility & Technical 1720 Maury Street Houston, Texas 77026 (713) 223-4971 local (713) 236-9422 fax BMC DALLAS Branch Facility 2015 California Crossing Dallas, Texas 75220 (972) 506-8496 local (972) 506-8478 fax BMC ATLANTA Branch Facility 319 Lee Industrial Road Austell, Georgia 30168 (770) 941-5141 local (770) 941-7344 fax BMC CHICAGO Branch Facility 1175 Carolina Road W. Chicago, Illinois 60185 (630) 231-7495 local (630) 231-7520 fax BMC DENVER Branch Facility 7505 East 41st Avenue Denver, Colorado 80216 (303) 322-3703 local (303) 322-3810 fax BMC PHOENIX Branch Facility 5717 W. Washington Street Phoenix, Arizona 85043 (602) 385-1237 local (210) 650-0379 fax BMC KANSAS CITY Branch Facility 1235 Southwest Boulevard Kansas City, Kansas 66103 (913) 227-0855 local (210) 650-0379 fax BMC OKLAHOMA CITY Branch Facility 1400 Exchange Avenue Oklahoma City, Oklahoma 73108 (405) 248-7404 local (210) 650-0379 fax BERRIDGE CALIFORNIA SALES CORPORATION* 18732 Corby Avenue Artesia, California 90701 (562) 402-2081 local Berridge Manufacturing Company is registered with the AIA Continuing Education System (AIA/CES) and is committed to developing quality learning activities in accordance with the CES criteria. Please call Berridge’s Staff Architect at 800-231-8127 to schedule a seminar. * Berridge California Sales Corporation is a separate entity from Berridge Manufacturing Company. Berridge Product Catalog - Spring 2016 | 5M | Printed in the USA. (562) 865-7878 fax