Züllig Transmitter
Transcription
Züllig Transmitter
Züllig Transmitter Example: Controlling waste water treatment with one TSS sensor and three D.O. sensors. The s-line transmitter is compatible with all digital Züllig probes. The signals from four probes can be processed at the same time. Advantages of s-line • Up to four seperate measurements with one transmitter • Easy operation • Individually configurable • Up to four measuring values can be displayed • Four analog outputs • Automatically set up to the connected probe. Sensor specific data are stored in the probe • Noise-insensitive Technical Highlights Variable display design Up to four measuring values can be displayed at the LED. Other measurement values can be scrolled or leafed through on the main menu with the turning knob. Combinations of Smart Sensors with s-line Parameter Probe type Dissolved Oxygen, Temperature Dissolved Oxygen, Temperature Dissolved Oxygen, Temperature Dissolved Oxygen, Temperature Turbidity, Suspended Solids Turbidity pH-Value pH-Value, Temperature Redox Conductivity, Temperature Level, Volume, Flow S14-S S15-S-25 ODO OH-S-25EX COSMOS®-25, COSMOS® EX TML-25 PH1-S-25 PH2-S-25EX RX-S-25EX LF-S-25 HT-68, LT-68 EX Load in % 100 80 30 10 30 20 10 10 10 40 20 = Is valid also for version EX for Zone Ex 1 Different probes burden the probe connection differently. The total load of the connected probes at each of the 2 probe connections (connection 1 and connection 2) may not exceed 100%. Characteristics Plug and Play All sensor-specific data are automatically read into the transmitter Digital data transfer by one signal cable only Two additional analog outputs available Compact design for panels or stand-alone use Profibus communication Plug-in connector Lowering cost of ownership • Up to four Smart Probes can be connected with one transmitter • Simplified start-up by easier installation using Smart Probes (integrated microprocessor) • Low installation costs due to multiple cable routings • Usage of cost-efficient standard cable • User-defined combination of individual probes Type of construction Technical Data Sensorbus . . . . . . . . . . . . . . . . . . . . Analog inputs . . . . . . . . . . . . . . . . . Analog outputs . . . . . . . . . . . . . . . . Relay outputs . . . . . . . . . . . . . . . . . Power supply voltage . . . . . . . . . . . Interfaces (option) . . . . . . . . . . . . . . Protection class . . . . . . . . . . . . . . . Temperature range . . . . . . . . . . . . . Enclosure . . . . . . . . . . . . . . . . . . . . up to 4 Smart Sensors 2 current signals 0/4…20 mA 4 current outputs 0/4…20 mA 4 potential free contact for twoway two-step controller or alarm/counter 90…264 VAC, 50/60 Hz or 18…36 VDC (optional) Profibus-DP Slave 2 s-line E, 0…50 °C s-line V, -20…50 °C (AC version with heating) Type E (panel version) IP50 Type V (field version) IP66 1441e02 21/02/2008 Subject to technical changes Instrumentation for Water and Waste Water Control Type V (outdoor) and Type E (mounting) Headquarter in Switzerland: Züllig AG CH-9424 Rheineck/Switzerland Phone +41(0)71 886 91 11 Telefax +41(0)71 886 91 66 www.zuellig.ch Representatives worldwide