Bulletin 100-G IEC Contactors • 315...710 kW, 400V • 350…900 Hp
Transcription
Bulletin 100-G IEC Contactors • 315...710 kW, 400V • 350…900 Hp
Bulletin 100-G IEC Contactors 315...710 kW, 400V 350…900 Hp, 460/575V 3-Pole contactors 4th add-on neutral switching pole AC and DC control Horizontal and vertical interlocking Mechanical latching Meets IEC, CE, and cULus Standards and Certifications Your order must include: cat. no. of the contactor selected, coil voltage code, overload relay suffix code, and, if required, cat. no. of any accessories. The Bulletin 100-G contactor product family provides reliable switching of motor loads up to 1200 A. A complete range of accessories including auxiliary contacts, mechanical latches, horizontal and vertical interlocks, and 4th add-on neutral switching poles provides maximum flexibility to meet a wide variety of application requirements. Standards Compliance and Certifications Standards Compliance EN/IEC 60947-4-1 IEC 60947 Type “1” Coordination CSA C22.2 No. 14 UL 508 Certifications CE Marked cULus Listed (File No. E 3125, Guide NLDX, NLDX7) Product Selection AC and DC Control AC- Switching of 3-phase motors—AC-2, AC-3 3-Phase AC-2, Auxiliary Cat. No. 1 AC-3 kW Contacts Rating (50 Hz), 400V Ie kW (50 Hz)‡ Hp (60 Hz) kW (50 Hz) [A] 40 230V400V500V690V200V230V460V575V400V N.O. N.C. °C 760 160 315 400 500 150 150 350 350 315 2 2 100-G55022 1000 220 400 500 630 200 250 500 500 400 2 2 100-G70022 1100 280 500 630 710 250 300 600 600 500 2 2 100-G86022 1200 315 560 750 850 — — — — 560 2 2 100-G100012 1350 375 710 850 1000 450 450 900 900 710 2 2 100-G120012 Package Quantity = 1 Discount Group PRO 1 N.O. contact used in control circuit. No UL/cUL ‡ Preferred value according to IEC 60072-1. Coil Voltage Code The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 50/60Hz: Cat. No. 100-G55022 becomes Cat. No.100-G550KD22. For Use [V] With: 10050/6 G550...100 0 Hz -G860 DC 100…11 110…12 200…22 220…24 345…38 380…41 400…44 440…48 0 0 0 0 0 5 0 0 — KD — KF — KN — KB KD For Use With: 100-G1000...100G1200 — KF — KN — KB — [V] 110…115110220…230220240380…400440480V 50/60 HzKD — KF — KA KN KB KU DC — ZD — ZA — — — — Price Adder For Type Available Control Voltages Special control voltages 100-G550…100-G860 24…600V 50/60 Hz, 24…440V DC 100-G1000…10048…600V 50/60 Hz, 48…440V G1200 DC No Surcharge >25 pieces Bulletin 100-G Accessories Control Modules 4-Pole 2-Pole Description Auxiliary Contact Block For mounting between T1 & T2 or between T2 & Standard Terminal marking for T3 mounting between Adjustable; provides T1 & T2 normal, delayed, or overlapping contacts Max. two Alternate terminal blocks/contactor marking for Alternate terminal mounting between marking tags included T2 & T3 2 N.O. and 2 N.C. contacts Auxiliary Contact Block For side mounting on either side of the Standard terminal contactor marking Max. four blocks/contactor Alternate terminal Alternate terminal marking tags included markings 1 N.O. and 1 N.C. contact Fourth Add-On Neutral Ith AC-1 500 A Switching Pole Left- or right-side Ith AC-1 1000A mountable Note: no UL/cUL For Use With 100-G550…100G860 Cat. No. 100-EF22 100-G1000…100G1200 100-EB11 100-G550 100-G700, 100-G860 100-G700, 100-G860 100-G1000, 100G1200 100-NP500-5 100-NP500-6 100-NP1000-6 100-NP1000-7 Direct and Impulse 100-G550 Mechanical Latch 100-FLAM5 Mechanical life: 0.5 Contact control million operations Direct and Impulse 100-G700, 100-G860 100-FLAM6 Direct and Impulse Contact control Control 100-G550 to 100100-MC00-5H Mechanical Interlock — Horizontal G550 100-G550 to 100100-MC00G700 or 100-G860 56H 100-G700 or 100100-MC00-6H G860 to 100-G700 or 100-G860 100-G700 or 100100-MC00G860 to 100-G1000 67H or 100-G1200 100-G1000 or 100- 100-MC00-7H G1200 to 100-G1000 or 100-G1200 Mechanical Interlock — Vertical 100-G550 to 100G550 100-G550 to 100G700 or 100-G860 100-G700 or 100G860 to 100-G700 or 100-G860 100-G700 or 100G860 to 100-G1000 or 100-G1200 100-G1000 or 100G1200 to 100-G1000 or 100-G1200 100-MC00-5V 100-MC0056V 100-MC00-6V 100-MC0067V 100-MC00-7V Package Quantity = 1 Coil Voltage Codes The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: Cat. No. 100-FLAM5 becomes Cat. No.100-FLAM5KD. For use with 100-G550... 100-G860 [V] 50-60 Hz 110...120 KD 220...240 KF 380...415 KN 440...480 KB For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Bulletin 100-G Specifications Electrical Data Cat. No. 100G550... AC-1, Three-phase Switching - IEC Ambient temperature: 40 °C Ie [A] 760 690V 230V [kW] 303 240V [kW] 316 400V [kW] 527 415V [kW] 546 500V [kW] 658 690V [kW] 908 Ambient temperature: 60 °C Ie [A] 605 690V 230V [kW] 241 240V [kW] 251 400V [kW] 419 415V [kW] 435 500V [kW] 524 690V [kW] 723 Continuous Current - UL/CSA [A] 520 General Purpose Rating 40 °C Switching of 3-phase Motors - IEC AC-2, AC-3 230/240V [A] 550 50 Hz/60 °C 400/415V [A] 550 500V [A] 550 690V [A] 500 230V [kW] 179 240V [kW] 187 400V [kW] 312 415V [kW] 324 500V [kW] 407 690V [kW] 510 AC-4 at 200000 operations 50 Hz 230/240V [A] 140 400/415V [A] 140 230V [kW] 45 240V [kW] 47 400V [kW] 78 415V [kW] 81 AC-4, Squirrel-cage motors with reversing and jogging at 20,000 (25,000), operations 230/240V [A] 360 400/415V [A] 350 230V [kW] 116 240V [kW] 120 400V [kW] 198 415V [kW] 206 100G700... 100G860... 100G1000 100G1200 1000 398 416 693 719 866 1195 1100 438 457 762 791 953 1315 1200 478 499 831 863 1039 1434 1350 538 561 935 970 1169 1613 800 319 333 554 575 693 956 700 870 347 362 603 625 753 1040 810 960 382 399 665 690 831 1147 — 1,085 432 451 752 780 940 1297 1215 700 700 700 630 228 238 414 430 518 657 860 860 860 700 280 293 509 528 636 730 1000 1000 1000 860 326 340 592 628 756 897 1200 1200 1200 1000 391 408 710 737 888 1043 180 180 57 60 101 105 210 210 67 70 118 122 260 260 83 87 146 151 300 300 97 101 170 176 430 420 139 151 238 247 520 520 170 177 295 300 (630) (630) (205) (214) (357) (359) (700) (700) (228) (245) (414) (424) At rated Voltage 415V and rated current: Life span - 25%. Cat. No. 100G550 100G700 100G860 100G1000... Switching of 3-phase Motors - UL/CSA 60 Hz/60 °C 200V [A] 414 552 692 — 230V [A] 360 602 722 — 460V [A] 414 590 708 — 575V [A] 336 472 576 — 200V [Hp] 150 200 250 — 230V [Hp] 150 250 300 — 460V [Hp] 350 500 600 — 575V [Hp] 350 500 600 — Rated making capacity AC-3 Ie 5500 7000 8600 10000 415V [A] 500V [A] 5500 7000 8600 10000 690V [A] 5500 7000 8600 10000 Rated Breaking capacity AC-3 Ie 4400 5600 6900 8000 240V [A] 400V [A] 4400 5600 6900 8000 415V [A] 4400 5600 6900 8000 500V [A] 4400 5600 6900 8000 690V [A] 4000 5100 5600 6900 Star-Delta Staring 50 Hz 230V [A] 953 1212 1490 1732 240V [A] 953 1212 1490 1732 400V [A] 953 1212 1490 1732 415V [A] 953 1212 1490 1732 500V [A] 953 1212 1490 1732 690V [A] 831 1091 1195 1490 230V [kW] 310 395 485 565 240V [kW] 324 412 507 589 400V [kW] 540 717 882 1025 415V [kW] 561 745 915 1088 500V [kW] 705 897 1102 1309 690V [kW] 883 1138 1247 1554 Wye-Delta Starting 60 Hz 230V [Hp] 250 400 500 650 460V [Hp] 600 800 1000 1300 575V [Hp] 600 800 1000 1500 Short-circuit Protection of Contactors without Overload Relay Fuse gG (aM) Type 1 500V [A] (630) 800 1000 1000 coordination 690V [A] (630) 800 1000 1000 (per IEC 60947-4-1) Switching of Three-phase Capacitor Inductivity of dispatching between parallel switched capacitor: min. 6 pH Single capacitors 40 °C 230V [kVar] 180 220 250 290 240V [kVar] 200 250 300 325 400V [kVar] 320 400 450 500 100G1200... 1185 1130 1062 864 450 450 900 900 12000 12000 12000 9600 9600 9600 9600 8000 2078 2078 2078 2078 2078 1732 677 707 1250 1278 1538 2078 750 1500 1500 1250 1000 330 360 575 55 °C 415V 500V 690V 230V 240V 400V 415V 500V 690V [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] Cat. No. Capacitor Banks 40 °C 230V [kVar] 240V [kVar] 400V [kVar] 415V [kVar] 500V [kVar] 690V [kVar] 55 °C 230V [kVar] 240V [kVar] 400V [kVar] 415V [kVar] 500V [kVar] 690V [kVar] DC Switching Switching of non- or slightly inductive loads, resistance furnaces DC-1 at 60 °C 1 Pole 24/48V [A] 2 Poles in series 24/48V [A] 3 Poles in series 24/48V [A] 110V [A] 220V [A] Shunt-Wound Motors Starting, plugging, reversing, plugging DC-3 at 60 °C 3 Poles in series 24/48V [A] Series-Wound Motors Starting, plugging, reversing, plugging DC-5 at 60 °C 3 Poles in series 24/48V [A] Lighting Loads Elec. Discharge. Lamps - AC - 5a, Non-Compensated [A] Compensated [A] Incandescent Lamps - AC - 5b, Electrical Endurance @ 100 000 [A] ops Switching Power Transformers AC - 6a Inrush = n · Ie [A] Ie Rated transformer current [A] 350 450 580 150 170 280 300 360 500 430 520 700 180 200 330 360 420 580 500 600 800 220 260 400 450 540 720 550 660 875 275 300 460 500 600 800 630 750 1000 325 350 550 600 720 950 100G550… 180 200 320 350 450 580 150 170 280 300 360 500 100G700… 220 250 400 430 520 700 180 200 330 360 420 580 100G860… 250 300 450 500 600 800 220 260 400 450 540 720 100G1000… 290 325 500 550 660 875 275 300 460 500 600 800 100G1200… 330 360 575 430 750 1000 325 350 550 600 720 950 645 645 645 480 315 760 760 760 560 400 930 930 930 630 450 1020 1020 1020 800 500 1150 1150 1150 900 600 605 800 870 960 1085 605 800 870 960 1085 450 360 570 460 700 550 850 660 1000 800 315 440 500 560 630 7440 248 9450 315 11700 390 13500 450 16200 540 n= 30 400V AC 500V AC 690V AC [kVA] [kVA] [kVA] [A] 172 215 269 371 218 273 339 472 270 338 376 580 312 390 538 675 374 468 645 810 435 630 774 900 1080 5500 5500 4400 3800 2300 1300 850 60 7000 7000 5600 5000 2800 1800 1150 60 8000 8000 6900 6000 3400 2000 1350 60 10000 10000 8000 7400 4000 2300 1600 60 12000 12000 9600 8500 4800 2700 1900 60 0.11 99 0.1 147 0.08 177 0.06 180 0.05 216 110 109 172 169 202 199 250 240 286 276 100G550… 100G700… n= 20 n= [A] 15 Rated Short-Time Withstand ICW, 60 °C 1s [A] 4s [A] 10 s [A] 15 s [A] 60 s [A] 240 s [A] 900 s [A] Minimum cooling time at zero [Min.] current Resistance and Energy Dissipation Main circuit resistance [m] Total energy dissipation at Ie AC-3 [W] Excess energy dissipation at Ie AC-3 AC Control [W] DC Control [W] Mechanical Data Cat. No. 100G860… 100G1000… Life Span in Millions of Operations Mechanical AC [Mil.] 5 5 5 1 Control DC [Mil.] 5 5 5 1 Control [kg] 13.8 26.4 28.4 50.3 Shipping Weights AC Control [lb] 30.4 58.1 62.5 110.8 DC [kg] 13.8 26.4 28.4 50.3 Control [lb] 30.4 58.1 62.5 110.8 Terminals Terminal Dimensions [mm] 6 x 40 8 x 50 8 x 50 10 x 50 Terminal screw hole size [mm] (1) x 13 (1) x 13 (1) x 15 (2) x 13 Hexagonal Bolt Terminations - Power Type Direct Connection b max. [mm] 50 60 60 60 c max. [mm] 20 20 25 25 s max. [mm] 2 x 5 2x5 2x6 2x6 13 15 2 x 13 min. [mm] 12.5 100G1200… 1 1 53.4 117.6 53.4 117.6 10 x 60 (2) x 13 60 25 2x8 2 x 13 Recommended Torque [N•m] 50 [ft.- 37 lb] Conductor/Wire Terminations Bus bar (Width) [mm] 40 Hex screw [in] 1/2 Recommended Torque [N•m] 42 [lb•in] 375 Auxiliary Contact [mm2] (2) x 2.5 Coils [mm2] (2) x 2.5 60 44 75 55 60 44 60 44 50 3/8 62 550 (2) x 2.5 (2) x 2.5 50 3/8 62 550 (2) x 2.5 (2) x 2.5 50 3/8 56 500 (2) x 2.5 (2) x 2.5 60 3/8 56 500 (2) x 2.5 (2) x 2.5 100G1000… 100G1200… Quantity indicated in ( ). Coil Data Cat. No. 100G550… 100G700… 100G860… Operating Limits AC- 50 Hz Pick-up [x Us] 0.85…1.1 Drop-out [x Us] 0.2…0.5 0.2…0.75 AC- 60 Hz Pick-up [x Us] 0.85…1.1 Drop-out [x Us] 0.2…0.5 0.2…0.75 DC Control Pick-up [x Us] 0.85…1.1 Drop-out [x Us] 0.2…0.5 0.2…0.75 Pickup and Holding Power AC- 50 Hz Pick-up [VA] 800…950 1350…1600 Hold-in [VA] 9…11 21…25 AC- 60 Hz Pick-up [VA] 800…950 1350…1600 Hold-in [VA] 9…11 21…25 DC Control Pick-up [W] 700…850 1300…1550 Hold-in [W] 8…10 18…22 Operating Times: Switching Delay AC Making delay [ms] 50…100 Breaking delay [ms] 20…50 /150…200/500…1000‡ DC Making delay [ms] 50…100 Breaking delay [ms] 20…50 /150…200/500…1000‡ 0.1…0.6 0.1…0.6 0.1…0.6 2400 70 2400 70 2100 60 50…100 25…50 50…100 25…50 Accelerates ‡ Delays Auxiliary Contacts Cat. No. AC Switching AC-1 100G550… Ith AC- 15 at rated voltage at 40 °C [A] 16 at 60 °C [A] 12 120V [A] 6 230V [A] 3 240V [A] 3 400V [A] 2 415V [A] 2 100G700… 100G860… 100G1000… 16 12 6 3 3 2 2 100G1200… DC Switching DC-13 control of electromagnets 500V [A] 1.5 690V [A] 1 24V DC [A] 6 48V DC [A] 3 110V [A] 1 DC 220V [A] 0.5 DC 1.5 1 6 3 1 0.5 Back-up Fuse Short-circuit protection without contact welding per IEC 60947-5 Fuse gG [A] 10 16 General Data Cat. No. Rated Isolation Voltage Ui IEC, AS, BS, SEV, [V] VDE, 0660 UL/CSA Impulse Voltage Uimp 1 minute per IEC 947-4 [KV] Rated Voltage - Main Control Ue AC 50/60 Hz [V] 100G550… 100G700… 100G860… 100-G1000… 100-G1200… 1,000V 600V 690V 600V 3,500V 2,500V 230, 240, 400, 415, 460, 500, 230, 240, 400, 415, 460, 500, 575, 690V 575, 690V DC [V] 24, 48, 110, 220, 440V Operating Frequency [Hz] 180/hr. for 0.25s start time - 42/hr. for 1s start time for AC Loads 50/60 Hz Class B per VDE 0660, table 22 Insulation Class of the Magnetic Coil Rated frequency of the Coil AC 50/60 Hz, DC Ambient Temperature Storage -40 °C…+80 °C Operation at rated current -25 °C…+60 °C Damp alternating conditions cyclical, per DIN 50 016 and 40 Climatic Withstand 046, part 38, IEC 60068 2000 m above sea level, per IEC 60947-1 Altitude IP00 IEC 60529/DIN 40 050 Type of Protection IEC 60947, UL 508, CSA C22.2, No. 14 Standards Compliance cULus, CE Certifications Cat. No. 100-G1000… is not cULus certified. Life-Load Curves 100-G550…100-G1200 AC-3 Switching of Running Three-phase Motors, Ue = 380…460V AC AC-1 Non or Slightly Inductive Loads, Resistance Furnaces AC-4 Jogging of Squirrel-cage Motors, Ue = 380…460V AC Life-Load Curves, Continued 100-G550…100-G1200 AC-3 90% Switching of Running Motors, Ue = 380…460V AC AC-4 10% Jogging Permissable Switching Rate 100-G550…100-G1200 Switching of Running Squirrel-cage Motors AC-3, Ue = 380…460V AC Starting Time ts = 0.25 s, Relative Running Time 40% Permissable Switching Rate, Continued 100-G550…100-G1200 Switching of Running Squirrel-cage Motors AC-3, Ue = 380…460V AC Starting Time ts = 1 s, Relative Running Time 40% 100-G550…100-G1200 Switching of Starting Motors (AC-2, and AC4) Uz = 380…460V AC Starting Time ted = 1 s, (<ts) Bulletin 100-G Approximate Dimensions Bulletin 100-G Contactors and Accessories Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Mounting Position Cat. No. a b b1 c c1 d d1 d2 e e1 e2 e3 100-G550 2202582282251649 22011012.5 4079 — 100-G700 28030727729120311 28017513 50101— 100-G860 28036132529120311 28017515 50101— 100-G100033449043434523113.53801202x135010040 100-G120033449043434523113.53801202x136010040 Contactor with Auxiliary contact block Mechanical side by side Interlock mm 100-G550/100-G550 a+42+a 100-G700, -860/100-G700, -860 a+32+a 100-G1000, -1200/100-G1000, -1200a+46+a 100-G550/100-G700, -860 a+37+a 100-G700, -860/100-G1000, -1200 a+73+a stacked vertically100-G550/100-G550 b+56 + b 100-G700, -860/100-G700, -860 b/2+380…480+b/2 100-G1000, -1200/100-G1000, -1200b+120…170+b 100-G550/100-G700, -860 b/2+400+b/2 100-G700, -860/100-G1000, -1200 b/2+570+b/2 4th add-on neutral switching pole 100-G550 a+74 100-G700, -860 a+68 100-G1000, -1200 a+76 Mechanical latch 100-G550 b+59 100-G700 b+64 100-G860 b+37 a Renewal Parts Bulletin 100-M Replacement Coils Description Pkg. Qty.Cat. No. 24V 50/60 Hz 10 MA014 48V 50/60 Hz 10 MA024 110V 50 Hz/110…120V 60 Hz 10 MA034 220V 50/60 Hz 10 MA050 240V 50/60 Hz 10 MA052 380V 50/60 Hz 10 MA062 440V 50 Hz/480V 60 Hz 10 MA082 12V DC 10 MB708 18V DC 10 MB710 24V DC 10 MB714 48V DC 10 MB724 60V DC 10 MB734 110V DC 10 MB744 125V DC 10 MB746 220V DC 10 MB766 24V DC with Diode Suppressor10 MD714 AC and DC coils are not interchangeable. Bulletin 100-C Replacement Coils AC Standard Control Voltages AC [V] Coil Code 50 Hz 60 Hz 50/60 Hz — 12 — 24 — 32 36 42 48 — 100 110 — 120 12 — — — 24 — — — — 24 36 — — — 48 — — — — 48 100…110 100 120 — — 110 — — Q R J K KJ V W X Y KY KP D KD P 100100-C23…100- 100100100C09…100- C37, 100L-C20 C40, - C60…100- C90 C16 C43 C85 Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. TA006 TC006 TD006 TE006 TF006 TA404 TC404 TD404 TE404 TF404 TA013 TC013 TD013 TE013 TF013 TA407 TC407 TD407 TE407 TF407 TA855 TC855 TD855 TE855 TF855 TA481 TC481 TD481 TE481 TF481 TA410 TC410 TD410 TE410 TF410 TA482 TC482 TD482 TE482 TF482 TA414 TC414 TD414 TE414 TF414 TA860 TC860 TD860 TE860 TF860 TA861 TC861 TD861 TE861 TF861 TA473 TC473 TD473 TE473 TF473 TA856 TC856 TD856 TE856 TF856 TA425 TC425 TD425 TE425 TF425 127 — — S 200 200…220 200 KG — 208 — H 200…220 208…240 — L — — 200…230 KL 220 240 — A 220…230 260 — F — — 230 KF 230…240 — — VA 240 277 — T — — 240 KA — 347 — I — 380 — E 380…400 440 — N — — 400 KN 400…415 — — G 440 480 — B — — 440 KB 500 — — M 550 600 — C TA428 TA862 TA049 TA296 TA864 TA474 TA441 TA851 TA440 TA480 TA858 TA065 TA067 TA071 TA863 TA457 TA475 TA859 TA479 TA476 TC428 TC862 TC049 TC296 TC864 TC474 TC441 TC851 TC440 TC480 TC858 TC065 TC067 TC071 TC863 TC457 TC475 TC859 TC479 TC476 TD428 TD862 TD049 TD296 TD864 TD474 TD441 TD851 TD440 TD480 TD858 TD065 TD067 TD071 TD863 TD457 TD475 TD859 TD479 TD476 TE428 TE862 TE049 TE296 TE864 TE474 TE441 TE851 TE440 TE480 TE858 TE065 TE067 TE071 TE863 TE457 TE475 TE859 TE479 TE476 TF428 TF862 TF049 TF296 — TF474 TF441 TF851 TF440 TF480 TF858 TF065 TF067 TF071 TF863 TF457 TF475 TF859 TF479 TF476 Coils, Continued DC Standard Control Voltage [V] 9 9V Diode 12 12V Diode 24 24 Diode 36 36V Diode 48 48V Diode 60 60V Diode 64 64V Diode 72 72V Diode 80 DC Coil 100Code C09…100C16 Cat. No. ZR TA766 DR — ZQ TA708 DQ — ZJ TA714 DJ TA714M ZW TA719 DW — ZY TA724 DY — ZZ TA774 DZ — ZB TA727 DB — ZG TA728 DG — ZE TA729 100-C23…100C37, 100L-C20 Cat. No. TC766 — TC708 — TC714 TC714M TC719 — TC724 — TC774 — TC727 — TC728 — TC729 100-C40, - 100C43 C60…100C85 Cat. No. Cat. No. TD766 — — TE766M TD708 — — TE708M TD714 — TD714M TE714M TD719 — — TE719M TD724 — — TE724M TD774 — — TE774M TD727 — — TE727M TD728 — — TE728M TD729 — 100-C90 Cat. No. — TF766M — TF708M — TF714M — TF719M — TF724M — TF774M — TF727M — TF728M — 80V Diode 110 110V Diode 115 115V Diode 125 125V Diode 220 220V Diode 230 230V Diode 250 250V Diode DE ZD DD ZP DP ZS DS ZA DA ZF DF ZT DT — TA733 — TA734 — TA737 — TA747 — TA749 — TA751 — — TC733 — TC734 — TC737 — TC747 — TC749 — TC751 — — TD733 — TD734 — TD737 — TD747 — TD749 — TD751 — TE729M — TE733M — TE734M — TE737M — TE747M — TE749F — TE751F Voltage operating range: 0.65…1.3 x Us. Voltage operating range: 0.7…1.25 x Us. Bulletin 190 IEC Modular Starter System AC Operating Coils Used with Cat. Nos. 190-A40, 190-CPS40, and 190R-CPS40 Voltage [V] Frequency [Hz] Cat. No. 24 50 JB407 24 60 JB013 110 50 JB473 120 60 JB473 208 60 JB049 220 50 JB474 240 60 JB474 380 50 JB454 415 50 JB457 440 50 JB475 480 60 JB475 550 50 JB476 600 60 JB476 Bulletin 193 Overload Relays with Current Transformers For Use With 193-HPD110 193-DPC88 193-DPD120 193-DPD200 193-EPD180 193-EPD300 193-FPD240 193-FPD40 193-GPD378 193-GPD630 Panel Adapter Assembly Cat. No. 40781-607-01 40781-607-01 40781-607-01 40781-607-01 40781-607-01 40781-607-01 40781-607-01 40781-607-01 40781-607-01 40781-607-01 Overload Relay Only Cat. No. 193-NX23 193-NX24 193-NX25 193-NX26 193-NX27 193-NX28 193-NX29 193-NX30 193-NX32 193-NX33 Contact kits for Cat. Nos. 100-A09…100-A30 are not available as replacement parts. TF729M — TF733M — TF734M — TF737M — TF747M — TF749F — TF751F AC Operating Coils Used with 193-GPD Devices Voltage Frequency [Hz]Cat. No. 24V AC 50 HA407 24V AC 60 HA013 110V AC 50 HA473 110 V AC60 — 120 V AC50 — 120V AC 60 HA473 208 V AC50 — 208V AC 60 HA049 220V AC 50 HA474 220V AC 60 HA051 240V AC 50 HA442 240V AC 60 HA474 277V AC 60 HA060 380V AC 50 HA454 380 V AC60 — 415V AC 50 HA457 440V AC 50 HA475 440V AC 60 HA071 480 V AC50 — 480V AC 60 HA475 500V AC 50 HA464 500 V AC60 — 600V AC 60 HA476 Description Coil Type For Use With Arc Chambers for Contactors Conventional100-D95 For 3-pole 100-D Contactors 100-D110 100-D140 100-D180 Electronic 100-D95 100-D110 100-D140 100-D180 100-D210 100-D250 100-D300 100-D420 Main Contacts for Contactors Conventional100-D95 Set for 3-pole 100-D Contactors 100-D110 100-D140 Cat. No. 100-DA-95 100-DA-110 100-DA-140 100-DA-180 100-DAE-95 100-DAE110 100-DAE140 100-DAE180 100-DAE210 100-DAE250 100-DAE300 100-DAE420 100-DC-95 100-DC-110 100-DC-140 Terminal Hardware Set of 6 100-D180 100-DC-180 Electronic 100-D95 100-DCE-95 100-D110 100-DCE-110 100-D140 100-DCE-140 100-D180 100-DCE-180 100-D210 100-DCE-210 100-D250 100-DCE-250 100-D300 100-DCE-300 100-D420 100-DCE-420 100-D630 100-DCE-630 100-D860 100-DCE-860 Conventional100-D95…D110 100-DHF110 100-D140…D180100-DHF180 Electronic 100-D95…D180 100-DHF180 100-D210…D420100-DHF420 100-D630…D860100-DHF860 Bulletin 100-D Replacement coils Conventional AC AC Standard Control Voltages 50 Hz 60 50/60 Hz Hz 24V — — — 24 — V 36 — V 42 — V — — 48 — V — 100V 120 — V — 110V 208 — V 32V 36V 48V 42V — 110V — — Conventional DC AC 100100100DC DC 100100100Coi D95…D D210…D D630…D Standar Coi D95…D D210…D D630…D l 180 420 860 d l 180 420 860 Co Cat. No. Cat. No. Cat. No. Control Co Cat. No. Cat. No. Cat. No. de Voltage de s K TG407 — — 12V ZQ TG708 — — J TG013 — — 24V ZJ TG714 — — V TG481 — — 36V ZWTG719 — — W TG410 — — 48V ZY TG724 — — Y TG414 — X TG482 — — — 60V 110V ZZ TG774 — ZD TG733 — — — KP TG861 — D TG473 — — — 125V 130V ZS TG737 — ZF TG738 — — — KN TG856 — H TG049 — — — 220V 240V ZA TG761 — ZL TG750 — — — — — 220…2 30V 240V — 200V — 220V 240 — V 277 — V — — 277V — — 230V — — 240V 380…4 440 — 00V V 415V 480 — V 440V — — 500V — — 550V 600 — V Electronic AC AC Standard Control Voltages 50 Hz — — — — — — — — — — — — — — KG TG862 — KL TG857 — A TG441 — — — — T TG480 — — KT TG060 KF TG851 KA TG858 N TG071 — — — — — — — — B TG475 — — G TG478 — M TG479 — C TG476 — — — — 250V ZT TG751 — — Electronic DC AC 100100-D420100DC DC 100100-D420100Coi D95…D D630…D Standar Coi D95…D D630…D l 300 860 d l 300 860 60 50/60 Co Cat. No. Cat. No. Cat. No. Control Co Cat. No. Cat. No. Cat. No. Hz Hz de Voltage de — 24V EJ TGE855 — — 24V EZ TGE708 — — J — 42…64 EY TGE864 — — 48…72 EZ TGE779 — — V V Y — 100V EP TGE861 THE861 TJE861 110…13EZ TGE780 THE780 — 0V D — 110…13ED TGE865 THE865 TJE865 ED — — TJE865 0V — 200V EG TGE862 THE862 — 200…25EZ TGE781 THE781 — 5V A — 208…27EA TGE866 THE866 — EA — — TJE879 7V — 200…22EG — — TJE878 0V — 230…25EA — — TJE879 0V — 277V ET — — TJE880 — 380…50EN TGE867 THE867 — 0V — 380…41EN — — TJE867 5V — 440…48EB — — TJE868 0V — 500V EM — — TJE869 600 — EC — — TJE870 V Applies to 100-D95…-D110 contactors only. Not available with 100-D140…-D180 contactors. Not available on 100/104-D300. Bulletin 100-G Renewal Parts Description Arcing Chamber For 3 poles For Use With Cat. No. 100-G550 100-AC550 100-G700, 100-AC860 100-G860 Arcing Chamber For 1 pole 100-G1000, 100-AC1200 100-G1200 Main Contact Set Set for 1 pole 100-G550 100-G700 100-G860 100-G1000 100-G1200 100-G1000, 100-G1200 Auxiliary Contact Block Special 2-pole design: 1 N.O. delayed make, 1 N.C. contact N.O. delayed make contact used for operation of the Feeder/Group Coil mechanism One contact block supplied standard with contactor 100-CP550 100-CP700 100-CP860 100-CP1000 100-CP1200 100-EB11DC Coils and Supply Modules AC Standard Control Voltages 50/60 Hz 110…120V 220…240V 380…415V 440…480V DC Standard Control VoltageCoil Code100-G550 100…110V 200…220V 345…380V 400…440V Coils sold in pairs. KD KF KN KB 100-G700...100G860 TX734TXS734TY734 TX747TXS747TY747 TX779TXS779TY779 TX780TXS780TY780 TYS734 TYS747 TYS779 TYS780 AC Standard Control Voltages 50/60 Hz 110…115V 220…230V 380…400V 440V Coil Code100-G1000...100-G1200 Coil Cat. No. Supply Module Cat. No. KD KF KN KB TZ734 TZ747 TZ779 TZS780 TZS734 TZS747 TZS779 TZS780
Similar documents
Luckies™ Summer 2016.
A personalised, self build, 3D world map featuring a top layer of scratchable foil so travels and trips can be recorded.
More information