R-09900 01 Kwal Paint product informaiton

Transcription

R-09900 01 Kwal Paint product informaiton
TRANSMITTAL
5995 Greenwood Plaza Blvd.
Suite 100
Greenwood Village, CO 80111-4710
303-571-5377
303-629-7467 (fax)
PROJECT:
TO:
ATTN:
Ph/Fax:
No. 14D1652-0022
DATE: 07/08/2014
APS-Pickens Tech Mobile 78 & Bldg B Renovation
Oz Architecture of Denver Inc
3003 Larimer St
Denver CO 80205
RE:
09900-Painting
Robert Fritz
JOB:
303-861-5704
WE ARE SENDING:
SUBMITTED FOR:
14D1652
ACTION TAKEN:
Shop Drawings
Approval
Approved as Submitted
Letter
Your Use
Approved as Noted
Prints
As Requested
Returned After Loan
Change Order
Review and Comment
Resubmit
Submit
Plans
SENT VIA:
Samples
Returned
Specifications / Product Data
Attached
Returned for Corrections
Other:
Separate Cover Via:
Due Date:
NOTES:
Item
Package
Code
Submittal
09900
09900.01
Rev. Copies Date
1
07/08/2014
Description
Status
Kwal Product informaiton
Architect Review
WALL PAINT COLOR - KWAL PEARL WHITE (64) SEMI-GLOSS
FRAME PAINT COLOR - SHERWIN WILLIAMS SW BEATRIX BROWN
CC:
Signed:
James Gettman
SUBMITTED
09900.01 Kwal Paint product information
Subcontractor - Dynamic Painting
GH Phipps has reviewed and herby
submits the attached in accordance with
the contract documents.
REVIEWED
ARCHITECT’S REVIEW IS FOR GENERAL CONFORMANCE
WITH DESIGN INTENT AND CONTRACT DOCUMENTS.
MA RK IN GS O R COM M EN TS D O NO T R EL IEVE THE
Note to Subcontractor/ Material Supplier:
Subcontractor/ Material Supplier remains
responsible for the confirmation and
correlation of dimensions at the jobsite;
fabrication processes and construction
techniques; coordination of the work with
the work of other trades; and satisfactory
performance of the work.
CONTRACTOR FROM COMPLIANCE WITH DRAWINGS AND
S P E C I F I C AT I O N S . T H E C O N T R A C T O R R E M A I N S
RESPONSIBLE FOR QUANTITY, DETAILS AND ACCURACY,
C O N F I R M I N G A N D C O R R E L AT I N G FA B R I C AT I O N
P R O C E S S E S , T E C H N I Q U E S O F A S S E M B LY, A N D
COORDINATION OF TRADES AND SITE CONDITIONS.
NO EXCEPTIONS TAKEN
REVISE & RESUBMIT
REVISE AS NOTED
REJECTED
RETURNED WITHOUT REVIEW
ARCHITECTURE
URBAN DESIGN
X
INTERIOR DESIGN
ROBERT FRITZ
BY
7-9-14
DATE
KWAL PAINT
1441 W BAYAUD AVE STE 2B
DENVER, CO 80223
(303) 777-3434
07/08/2014
DYNAMIC PAINTING CO INC
8585 FIELD CT
ARVADA CO 800051524
Re: Submittal for Pickens Technical College
Dear Terry Hirtz:
Thank you for considering Kwal Paint products for the Pickens Technical College project. Included in
this package is the Kwal Paint submittal for the above referenced project.
Should you require assistance or have any questions or concerns, please contact me at (720)
841-4802 or e-mail me at swrepQ114@sherwin.com.
Sincerely,
RANDY CONDELLO
Kwal Paint
Sales Representative
Pickens Technical College
500 Airport Blvd.
Aurora, CO 80011
DYNAMIC PAINTING CO INC
8585 FIELD CT
ARVADA, CO 800051524
Prepared By:
RANDY CONDELLO
Sales Representative
swrepQ114@sherwin.com
(720) 841-4802
SCHEDULE
Interior Finishes
Drywall
Primer: RC1520006 - ULTRATECH LATEX MULTI SOLUTION PRIMER
2 Coats: RC1360001 - ULTRATECH INT ZERO VOC SEMI-GLOSS
Concrete Block (CMU)
Block Filler: RC3020006 - ULTRATECH INTERIOR/EXTERIOR 100% ACRYLIC BLOCK FILLER
Hollow Metal Doors and Frames
2 Coats: B42W00111 - Metalatex® Semi-Gloss Acrylic Coating Extra White/Tint Base
END OF SECTION
SURFACE PREPARATION
1) Drywall (Interior and Exterior)
Must be clean and dry. All nail heads must be set and spackled. Joints must be taped and covered
with a joint compound. Spackled nail heads and tape joints must be sanded smooth and all dust
removed prior to painting. Exterior surfaces must be spackled with exterior grade compounds.
END OF SPECIFICATION
Data Pages
UltraTech
Interior Latex Multi-Solution Primer/Sealer C152
PRODUCT SPECIFICATIONS
UltraTech C152 is a premium architectural/commercial
interior latex primer/sealer. This formulation will meet
the quality requirements of painters, architects and
interior designers. Great for commercial, new home
construction, hospitality and residential usage where a
high level of performance is desired.
Resin Type
Vinyl Acrylic
Finish
< 5 @ 60°
Maximum VOC Content
50 g/L (0.42 lbs/ gal)
Solids
by Weight
42% ± 2%
by Volume
28% ± 2%
Coverage
300-400 sq. ft./gallon
Drying Time @ 77°F (25°C) & 50% RH
to Touch
1 hour
to Recoat
4 hours
NOTE: Drying times listed may vary depending on temperature,
humidity, film build, color, and air movement.
FEATURES








Ultra low VOC
Low odor
For drywall, plaster, wood & masonry
For walls and ceilings
Easy application
Quick drying & recoat
Easy water & soap cleanup
Not manufactured with lead, mercury or chromate
containing materials
 Does not contain crystalline silica or ethylene glycol
Weight Per Gallon
Wet Film Thickness (WFT)
Dry Film Thickness (DFT)
Colors
10.4 lbs
4.0 mils
1.1 mils
White
CONFORMANCE (as of 01/01/12)
EPA
OTC
CARB
SCAQMD
CALGreen Code
MPI
Yes
Yes
Yes
Yes
Yes
50
LEED® 2009 NC
LEED® 2009 CI
LEED® 2009 CS
LEED® 2009 Healthcare
NGBS
Yes
Yes
Yes
Yes
Yes
SUBSTRATE RECOMMENDATIONS
DRYWALL / PLASTER
C152 UltraTech Interior Latex Multi-Solution Primer/Sealer
CMU (Concrete Block / Cinder Block)
C302 UltraTech 100% Acrylic Block Filler
MASONRY
C152 UltraTech Interior Latex Multi-Solution Primer/Sealer
WOOD / SYNTHETIC WOOD
C152 UltraTech Interior Latex Multi-Solution Primer/Sealer
FERROUS METAL / NON-FERROUS METAL
C309 UltraTech Universal WB Metal Primer
APPLICATION
 Use a nylon/polyester brush.
 Use a 3/8" to 3/4" nap roller cover, depending on
surface texture.
 Use a tip size from .015" to .021".
 Stir thoroughly before and during use.
 Do not apply when surface or air temperature is
below 50°F (10°C).
 Apply coating evenly while maintaining a wet edge
to prevent lapping.
continued on back
UltraTech Interior Latex Multi-Solution Primer/Sealer C152
DESCRIPTION & INTENDED USE
UltraTech
UltraTech Interior Latex Multi-Solution Primer/Sealer C152
Interior Latex Multi-Solution Primer/Sealer C152
SURFACE PREPARATION
LIMITATIONS
General Surface Preparation: All surfaces must be clean,
dry, sound, and free from contaminants such as loose and
peeling paint, dirt, dust, grease, oil, wax, concrete curing
agents and bond breakers, efflorescence, rust, and chalk.
Mold and mildew must be treated and any residues
removed. Dull any glossy surfaces, repair damaged areas
with appropriate patching material, and allow to dry.
Prime all new surfaces and repaired areas with an
appropriate primer.
For interior use only. Do not use on floors.
High humidity and/or cooler temperatures will prolong dry
time of this product. Do not expose to moisture or extreme
temperature change for at least 48 hours after painting. Avoid
frost, fog and damp conditions.
Substrate Specific:
Drywall/Plaster
 Allow new drywall and plaster finishes to properly cure
(pH below 10) before application of primer and finish
coats.
Masonry
 Allow new masonry surfaces to cure before application of
primer and finish coats.
Wood
 Two coats of stain-blocking wood primer may be
necessary on lumber subject to tannin bleed, such as,
redwood and cedar.
WARNING! If you scrape, sand, or remove old paint, you
may release lead dust. LEAD IS TOXIC. EXPOSURE TO
LEAD DUST CAN CAUSE SERIOUS ILLNESS, SUCH AS
BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT
WOMEN SHOULD ALSO AVOID EXPOSURE. Wear a
NIOSH approved respirator to control lead exposure. Clean
up carefully with a HEPA vacuum and a wet mop. Before
you start, find out how to protect yourself and your family
by contacting the National Lead Information Hotline at
1-800-424-LEAD or log on to www.epa.gov/lead.
THINNING & CLEANUP
This product is designed to be used at package
consistency. However, if thinning is desired due to specific
conditions, thin with clean water not to exceed ½ pint per
gallon of paint. Clean tools, equipment, and work area with
warm, soapy water.
CAUTIONS
WARNING!
HARMFUL IF SWALLOWED
IMPORTANT! Spray mist of any material may be hazardous. Spray
equipment must be in good condition and used with care in
accordance with manufacturer’s instructions. The use of an
appropriate respirator, eye protection and protective clothing is
recommended. Close container after use.
FIRST AID: If you experience difficulty in breathing, leave the area
to obtain fresh air. If continued difficulty is experienced, get
medical assistance immediately. In case of eye contact, flush
immediately with plenty of water for at least 15 minutes and get
medical attention, for skin, wash thoroughly with soap and water.
If swallowed, do not induce vomiting. Get medical attention
immediately. In case of spillage, absorb with inert material and
dispose of in accordance with applicable regulations.
KEEP OUT OF REACH OF CHILDREN
KEEP FROM FREEZING
SEE MATERIAL SAFETY DATA SHEET
For Chemical Emergency ONLY (spill, leak, fire, exposure or
accident), call ChemTrec at 1-800-424-9300.
WARRANTY
Comex warrants that at the time of sale this product conforms
with applicable Comex specifications and is free of
manufacturing defects. Comex’s sole liability for products
proven defective, and Purchaser’s sole remedy, if any, shall be
replacement of the product or refund of the purchase price
paid, at the sole option of Comex. This warranty is not
transferable. TO THE MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, MANUFACTURER MAKES NO OTHER
WARRANTIES, GUARANTEES, OR REPRESENTATIONS OF
ANY KIND, EITHER EXPRESS OR IMPLIED, OR BY USAGE OF
TRADE, AND HEREBY EXPRESSLY EXCLUDES AND
DISCLAIMS
ALL
IMPLIED
WARRANTIES,
OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. IN NO EVENT SHALL COMEX BE LIABLE FOR
PUNITIVE, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES OF ANY KIND.
Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation
may not apply to you. This Limited Warranty gives you specific
legal rights and you may have other rights which vary from
State to State.
STORAGE & DISPOSAL
Protect during storage from freezing and temperatures
above 95°F. Consult your local city or environmental
regulatory agency for guidance on disposal options. Do
not pour down a drain or storm sewer.
Comex Family of Brands
5575 DTC Parkway, Suite 100
Greenwood Village, CO 80111
Information phone: 1-800-383-8406
07/2012 (06/2012)
The information provided on this product data sheet (“Information”) is correct to the best of our knowledge, information, and belief at the date of its publication. The Information given is designed only as a general
guide and is not to be considered as a warranty or quality specification. The Information is subject to change without prior notice. Consult your sales representative to obtain the most recent product data sheet.
UltraTech
Interior Latex Low Odor/Zero-VOC* Semi-Gloss Finish C136
DESCRIPTION & INTENDED USE
PRODUCT SPECIFICATIONS
UItraTech C136 is a premium architectural/commercial
interior low odor/zero-VOC* semi-gloss finish.
UltraTech C136 has been developed with sustainable
design properties to increase product life cycle by
providing excellent scrubbability on properly prepared,
new or previously painted interior surfaces. Architects,
painters, designers and engineers can specify this
product with confidence when aesthetics and
performance must meet the highest demands, and
minimal disruption to occupied spaces is desired.
Resin Type
Finish
Maximum VOC Content
 Low odor – perfect for occupied spaces
 Anti-Microbial – contains an additive that helps
inhibit growth of microbes on the surface of the
dried paint film
 For offices & homes
 For healthcare facilities
 Scrubbable finish
 Easy application
 Quick drying & recoat
 Easy water & soap cleanup
 Not manufactured with lead, mercury or chromate
containing materials
 Does not contain crystalline silica or ethylene glycol
SYSTEM RECOMMENDATIONS
DRYWALL
1 coat: C153 UltraTech Interior Zero-VOC Primer
2 coats: C136 UltraTech Interior Zero-VOC Semi-Gloss
CMU (Concrete Block / Cinder Block)
1 coat: C302 UltraTech 100% Acrylic Block Filler*
2 coats: C136 UltraTech Interior Zero-VOC Semi-Gloss
MASONRY
1 coat: C153 UltraTech Interior Zero-VOC Primer
2 coats: C136 UltraTech Interior Zero-VOC Semi-Gloss
WOOD / SYNTHETIC WOOD
1 coat: C153 UltraTech Interior Zero-VOC Primer
2 coats: C136 UltraTech Interior Zero-VOC Semi-Gloss
FERROUS METAL / NON-FERROUS METAL
1 coat: C309 UltraTech Universal WB Metal Primer*
2 coats: C136 UltraTech Interior Zero-VOC Semi-Gloss
*These primers contain relatively low amounts of VOCs, but could
create slight, noticeable odors.
*Per EPA Test Method 24. Addition of colorants and additives may
increase VOC content.
Solids
by Weight
48% ± 2%
by Volume
35% ± 2%
Coverage
300-400 sq. ft./gallon
Drying Time @ 77°F (25°C) & 50% RH
to Touch
1 hour
to Recoat
4 hours
NOTE: Drying times listed may vary depending on temperature,
humidity, film build, color, and air movement.
Weight Per Gallon
10.3 lbs
Wet Film Thickness (WFT)
4.0 mils
Dry Film Thickness (DFT)
1.4 mils
Tint Bases
White, Medium, Deep & Neutral
CONFORMANCE (as of 01/01/12)
EPA
Yes
OTC
Yes
CARB
Yes
SCAQMD
Yes
CALGreen Code Yes
MPI
54 &147
LEED® 2009 NC
LEED® 2009 CI
LEED® 2009 CS
LEED® 2009 Healthcare
NGBS
Yes
Yes
Yes
Yes
Yes
APPLICATION
 Use a nylon/polyester brush.
 Use a 1/4" to 1/2" nap roller cover, depending on
surface texture
 Use a tip size from .015" to .019".
 Stir thoroughly before and during use.
 Do not apply when surface or air temperature is
below 50°F (10°C).
 Apply coating evenly while maintaining a wet edge
to prevent lapping.
continued on back
UltraTech Interior Latex Low Odor/Zero-VOC* Semi-Gloss Finish C136
FEATURES
100% Acrylic
Semi-Gloss: 55-65 @ 60°
0 g/L (0 lbs/ gal)*
UltraTech
UltraTech Interior Latex Low Odor/Zero-VOC* Semi-Gloss Finish C136
Interior Latex Low Odor/Zero-VOC* Semi-Gloss Finish C136
SURFACE PREPARATION
LIMITATIONS
General Surface Preparation: All surfaces must be clean,
dry, sound, and free from contaminants such as loose and
peeling paint, dirt, dust, grease, oil, wax, concrete curing
agents and bond breakers, efflorescence, rust, and chalk.
Mold and mildew must be treated and any residues
removed. Dull any glossy surfaces, repair damaged areas
with appropriate patching material, and allow to dry.
Prime all new surfaces and repaired areas with an
appropriate primer.
For interior use only. Do not use on floors.
Substrate Specific:
Drywall
 Allow new drywall finishes to properly cure before
application of primer and finish coats.
Masonry
 Allow new masonry surfaces to cure before application of
primer and finish coats.
 Power-wash all tilt-up and poured-in-place concrete to
remove any bond-breakers or other construction residue.
Wood / Synthetic Wood
 Two coats of stain-blocking wood primer may be
necessary on lumber subject to tannin bleed, such as,
redwood and cedar.
Metal (Ferrous & Non-Ferrous)
 Galvanized steel and aluminum should be solvent
cleaned in accordance with SSPC-SP1 and then etched
either chemically or via light blast cleaning with nonmetallic abrasive.
WARNING! If you scrape, sand, or remove old paint, you
may release lead dust. LEAD IS TOXIC. EXPOSURE TO
LEAD DUST CAN CAUSE SERIOUS ILLNESS, SUCH AS
BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT
WOMEN SHOULD ALSO AVOID EXPOSURE. Wear a
NIOSH approved respirator to control lead exposure. Clean
up carefully with a HEPA vacuum and a wet mop. Before
you start, find out how to protect yourself and your family
by contacting the National Lead Information Hotline at
1-800-424-LEAD or log on to www.epa.gov/lead.
Wait after 30 days or when paint has fully cured before
cleaning the surface with non-abrasive, mild detergent
solution and cellulose sponge.
High humidity and/or cooler temperatures will prolong dry time
of this product. Do not expose to moisture or extreme
temperature change for at least 48 hours after painting. Avoid
frost, fog and damp conditions.
CAUTIONS
WARNING!
HARMFUL IF SWALLOWED
IMPORTANT! Spray mist of any material may be hazardous. Spray
equipment must be in good condition and used with care in
accordance with manufacturer’s instructions. The use of an
appropriate respirator, eye protection and protective clothing is
recommended. Close container after use.
FIRST AID: If you experience difficulty in breathing, leave the area
to obtain fresh air. If continued difficulty is experienced, get
medical assistance immediately. In case of eye contact, flush
immediately with plenty of water for at least 15 minutes and get
medical attention, for skin, wash thoroughly with soap and water.
If swallowed, do not induce vomiting. Get medical attention
immediately. In case of spillage, absorb with inert material and
dispose of in accordance with applicable regulations.
KEEP OUT OF REACH OF CHILDREN
KEEP FROM FREEZING
SEE MATERIAL SAFETY DATA SHEET
For Chemical Emergency ONLY (spill, leak, fire, exposure or
accident), call ChemTrec at 1-800-424-9300.
WARRANTY
This product is designed to be used at package
consistency. However, if thinning is desired due to specific
conditions, thin with clean water not to exceed ½ pint per
gallon of paint. Clean tools, equipment, and work area with
warm, soapy water.
Comex warrants that at the time of sale this product conforms
with applicable Comex specifications and is free of manufacturing
defects. Comex’s sole liability for products proven defective, and
Purchaser’s sole remedy, if any, shall be replacement of the
product or refund of the purchase price paid, at the sole option of
Comex. This warranty is not transferable. TO THE MAXIMUM
EXTENT PERMITTED BY APPLICABLE LAW, MANUFACTURER
MAKES NO OTHER WARRANTIES, GUARANTEES, OR
REPRESENTATIONS OF ANY KIND, EITHER EXPRESS OR
IMPLIED, OR BY USAGE OF TRADE, AND HEREBY EXPRESSLY
EXCLUDES AND DISCLAIMS ALL IMPLIED WARRANTIES, OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. IN NO EVENT SHALL COMEX BE LIABLE FOR PUNITIVE,
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY
KIND.
STORAGE & DISPOSAL
Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation may not apply
to you. This Limited Warranty gives you specific legal rights and
you may have other rights which vary from State to State.
Protect during storage from freezing and temperatures
above 95°F. Consult your local city or environmental
regulatory agency for guidance on disposal options. Do
not pour down a drain or storm sewer.
Comex Family of Brands
5575 DTC Parkway, Suite 100
Greenwood Village, CO 80111
Information Phone: 1-800-383-8406
THINNING & CLEANUP
06/2012
The information provided on this product data sheet (“Information”) is correct to the best of our knowledge, information, and belief at the date of its publication. The Information given is designed only as a general
guide and is not to be considered as a warranty or quality specification. The Information is subject to change without prior notice. Consult your sales representative to obtain the most recent product data sheet.
UltraTech
Interior/Exterior 100% Acrylic Block Filler C302
PRODUCT SPECIFICATIONS
UltraTech C302 is a premium architectural/commercial
100% acrylic block filler. UltraTech C302 has been
developed with sustainable design properties to
increase product life cycle by providing excellent filling
properties and alkali resistance on interior and exterior
cinder and concrete block. It can be topcoated with
water-based or solvent-based topcoats. Architects,
painters, designers and engineers can specify this
product with confidence when aesthetics and
performance must meet the highest demands.
Resin Type
100% Acrylic
Finish
< 5 @ 60°
Maximum VOC Content
50 g/L (0.42 lbs/gal)
Solids
by Weight
68% ± 2%
by Volume
49% ± 2%
Coverage
75-125 sq. ft./gallon
Drying Time @ 77°F (25°C) & 50% RH
to Touch
2 hours
to Recoat
8 hours
NOTE: Drying times listed may vary depending on temperature,
humidity, film build, color, and air movement.
FEATURES








Seals
Fills voids
Provides a uniform surface
For concrete & cinder block
For masonry
Quick drying & recoat
Easy water & soap cleanup
Not manufactured with lead, mercury or chromate
containing materials
 Does not contain crystalline silica or ethylene glycol
SUBSTRATE RECOMMENDATIONS
Weight Per Gallon
Wet Film Thickness (WFT)
Dry Film Thickness (DFT)
Colors
13.3 lbs
12.8 mils
6.3 mils
White
CONFORMANCE (as of 01/01/12)
EPA
OTC
CARB
SCAQMD
CALGreen Code
MPI
Yes
Yes
Yes
Yes
Yes
4
LEED® 2009 NC
LEED® 2009 CI
LEED® 2009 CS
LEED® 2009 Healthcare
NGBS
Yes
Yes
Yes
Yes
Yes
APPLICATION
DRYWALL
C152 UltraTech Interior Latex Multi-Solution Primer/Sealer
CMU (Concrete Block / Cinder Block)
C302 UltraTech 100% Acrylic Block Filler
MASONRY
C251 Flex Lox Acrylic-Epoxy Masonry Primer/Sealer
WOOD / SYNTHETIC WOOD
C312 UltraTech Int/Ext 100% Acrylic Wood Primer
FERROUS METAL / NON-FERROUS METAL
C309 UltraTech Universal WB Metal Primer
 Use a nylon/polyester brush.
 Use a 1/2" to 1 1/4" nap roller cover, depending on
surface texture.
 Use a tip size of .028".
 Stir thoroughly before and during use.
 If applied by spray, UltraTech C302 must be backrolled or brushed into the surface pores and mortar
joints.
 Do not apply when surface or air temperature is
below 50°F (10°C).
 Apply coating evenly while maintaining a wet edge
to prevent lapping.
continued on back
UltraTech Interior/Exterior 100% Acrylic Block Filler C302
DESCRIPTION & INTENDED USE
UltraTech
Interior/Exterior 100% Acrylic Block Filler C302
SURFACE PREPARATION
LIMITATIONS
General Surface Preparation: All surfaces must be clean,
dry, sound, and free from contaminants such as loose and
peeling paint, dirt, dust, grease, oil, wax, concrete curing
agents and bond breakers, efflorescence, rust, and chalk.
Mold and mildew must be treated and any residues
removed. Dull any glossy surfaces, repair damaged areas
with appropriate patching material, and allow to dry.
Prime all new surfaces and repaired areas with an
appropriate primer.
Do not use on floors. Do not use on below-grade surfaces that
are subject to hydrostatic pressures.
UltraTech Interior/Exterior 100% Acrylic Block Filler C302
Substrate Specific:
CMU (Concrete Block / Cinder Block)
 Allow new masonry surfaces to cure before application of
primer and finish coats.
WARNING! If you scrape, sand, or remove old paint, you
may release lead dust. LEAD IS TOXIC. EXPOSURE TO
LEAD DUST CAN CAUSE SERIOUS ILLNESS, SUCH AS
BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT
WOMEN SHOULD ALSO AVOID EXPOSURE. Wear a
NIOSH approved respirator to control lead exposure. Clean
up carefully with a HEPA vacuum and a wet mop. Before
you start, find out how to protect yourself and your family
by contacting the National Lead Information Hotline at
1-800-424-LEAD or log on to www.epa.gov/lead.
High humidity and/or cooler temperatures will prolong dry
time of this product. Do not expose to moisture or extreme
temperature change for at least 48 hours after painting. Avoid
frost, fog and damp conditions.
CAUTIONS
WARNING!
HARMFUL IF SWALLOWED
IMPORTANT! Spray mist of any material may be hazardous. Spray
equipment must be in good condition and used with care in
accordance with manufacturer’s instructions. The use of an
appropriate respirator, eye protection and protective clothing is
recommended. Close container after use.
FIRST AID: If you experience difficulty in breathing, leave the area
to obtain fresh air. If continued difficulty is experienced, get
medical assistance immediately. In case of eye contact, flush
immediately with plenty of water for at least 15 minutes and get
medical attention, for skin, wash thoroughly with soap and water.
If swallowed, do not induce vomiting. Get medical attention
immediately. In case of spillage, absorb with inert material and
dispose of in accordance with applicable regulations.
KEEP OUT OF REACH OF CHILDREN
KEEP FROM FREEZING
SEE MATERIAL SAFETY DATA SHEET
For Chemical Emergency ONLY (spill, leak, fire, exposure or
accident), call ChemTrec at 1-800-424-9300.
WARRANTY
THINNING & CLEANUP
This product is designed to be used at package
consistency. Clean tools, equipment, and work area with
warm, soapy water.
STORAGE & DISPOSAL
Protect during storage from freezing and temperatures
above 95°F. Consult your local city or environmental
regulatory agency for guidance on disposal options. Do
not pour down a drain or storm sewer.
Comex warrants that at the time of sale this product conforms
with applicable Comex specifications and is free of manufacturing
defects. Comex’s sole liability for products proven defective, and
Purchaser’s sole remedy, if any, shall be replacement of the
product or refund of the purchase price paid, at the sole option of
Comex. This warranty is not transferable. TO THE MAXIMUM
EXTENT PERMITTED BY APPLICABLE LAW, MANUFACTURER
MAKES NO OTHER WARRANTIES, GUARANTEES, OR
REPRESENTATIONS OF ANY KIND, EITHER EXPRESS OR
IMPLIED, OR BY USAGE OF TRADE, AND HEREBY EXPRESSLY
EXCLUDES AND DISCLAIMS ALL IMPLIED WARRANTIES, OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. IN NO EVENT SHALL COMEX BE LIABLE FOR PUNITIVE,
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY
KIND.
Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation may not apply
to you. This Limited Warranty gives you specific legal rights and
you may have other rights which vary from State to State.
Comex Family of Brands
5575 DTC Parkway, Suite 100
Greenwood Village, CO 80111
Information Phone: 1-800-383-8406
06/2012
The information provided on this product data sheet (“Information”) is correct to the best of our knowledge, information, and belief at the date of its publication. The Information given is designed only as a general
guide and is not to be considered as a warranty or quality specification. The Information is subject to change without prior notice. Consult your sales representative to obtain the most recent product data sheet.
METALATEX®
Protective
&
Marine
Coatings
SEMI-GLOSS COATING
B42 SERIES
Revised: March 27, 2014
1.10
PRODUCT DESCRIPTION
RECOMMENDED USES
METALATEX SEMI-GLOSS COATING is a durable interior/exterior
multi-purpose, 100% acrylic emulsion coating. Designed for new
construction and maintenance applications in light to moderate
industrial environments.
For use over prepared:
• Galvanizing
•Wood (with primer)
•Masonry
• Aluminum
•Zinc rich primers
• Concrete
•Structural steel (with primer)
•
•
•
•
•
Examples:
• Buildings
• Machinery
• Piping
Mild alkali / Acid resistant
Interior/exterior all-purpose maintenance coating
Topcoat for zinc-rich primers
Low odor, low VOC
Outstanding application characteristics
• Storage Tanks
• Railing
• Machine applications
• Suitable for use in USDA inspected facilities
• Conforms to AWWA D102 OCS #3
• Acceptable for use in high performance architectural applications.
PERFORMANCE CHARACTERISTICS
PRODUCT CHARACTERISTICS
Finish:
Semi-Gloss
Color:
Wide range of colors including
safety colors
Volume Solids:
38% ± 2%
may vary by color
Weight Solids:
48% ± 2%
may vary by color
*unless otherwise noted below
VOC (calculated):
<100 g/L; .83 lb/gal
Extra White
Test Name
Recommended Spreading Rate per coat:
Wet mils (microns)
Dry mils (microns)
~Coverage sq ft/gal (m2/L)
Minimum
4.0 (100)
1.5 (37)
150 (3.7)
Maximum
11.0 (275)
4.0 (100)
395 (9.7)
Theoretical coverage sq ft/gal
608 (14.9)
(m2/L) @ 1 mil / 25 microns dft
NOTE: Brush or roll application may require multiple coats to
achieve maximum film thickness and uniformity of appearance.
Drying Schedule @ 4.0 mils wet (100 microns):
To touch:
To handle:
To recoat:
To cure:
@ 55°F/13°C
@ 77°F/25°C
50% RH
@ 100°F/38°C
3 hours
7 hours
18 hours
30 days
30 minutes
1 hour
4 hours
20 days
10 minutes
1 hour
3 hours
10 days
Drying time is temperature, humidity, and film thickness dependent.
Shelf Life:
Flash Point:
Reducer/Clean Up:
36 months, unopened
Store indoors at 50°F (10°C) to
100°F (38°C)
>200°F (93°C), PMCC
Water
Substrate*: Steel
Surface Preparation*: SSPC-SP6
System Tested*:
1 ct. DTM Acrylic Primer/Finish @ 3 mils (75 microns) dft
1 ct. Metalatex Semi-Gloss @ 3 mils (75 microns) dft
Test Method
ASTM D4060, CS17
wheel, 1000 cycles, 1
kg load
ASTM D4541
ASTM D2794
490 psi
160 in. lbs.
ASTM D2485
250°F (121°C)
Exterior Durability
1 year, 45° South
Excellent, no
color change, 5
unit gloss drop
Flexibility
(cold rolled steel)
Moisture
Condensation
Resistance
Pencil Hardness
Salt Fog
Thermal Shock
ASTM D522, 180°
bend, 1/4" mandrel
Passes
ASTM D4585, 100°F
(38°C), 120 hours
Good
Abrasion
Resistance
Adhesion
Direct Impact
Dry Heat
Resistance
Results
314 mg loss
ASTM D3363
B
ASTM B117, 250 hours Good
ASTM D2246 (5 cycles) Good
Provides performance comparable to products formulated to federal
specification: A-A-50570, SSPC-Paint 24.
www.sherwin-williams.com/protective
continued on back
METALATEX®
Protective
&
Marine
Coatings
SEMI-GLOSS COATING
B42 SERIES
PRODUCT INFORMATION
SURFACE PREPARATION
RECOMMENDED SYSTEMS
Dry Film Thickness / ct.
Mils
(Microns)
Steel, alkyd primer:
1 ct. Kem Bond HS Universal
Metal Primer
2 cts. Metalatex Semi-Gloss Coating
2.0-5.0
1.5-4.0
(50-125)
(37-100)
2.5-5.0
1.5-4.0
(62.5-125)
(37-100)
Steel, water based primer:
1 cts. DTM Acrylic Primer/Finish
2 cts. Metalatex Semi-Gloss Coating
1.10
Surface must be clean, dry, and in sound condition. Remove all oil,
dust, grease, dirt, loose rust, and other foreign material to ensure
adequate adhesion.
Refer to product Application Bulletin for detailed surface preparation information.
Minimum recommended surface preparation:
* Iron & Steel:
SSPC-SP2
Aluminum:
SSPC-SP1
Galvanizing:
SSPC-SP1
Concrete & Masonry:
SSPC-SP13/NACE 6, or
ICRI No. 310.2, CSP 1-3
* Wood:
FRP/PVC
Aluminum:
2 cts. Metalatex Semi-Gloss Coating
1.5-4.0
(37-100)
1.5-4.0
(37-100)
Clean, Dry and sanded smooth
Clean, Dry, Sand/Abrade
* Primer required.
Galvanizing:
1 cts. Metalatex Semi-Gloss Coating
Aluminum/Galvanizing, water based primer:
1 ct. DTM Wash Primer
2 cts. Metalatex Semi-Gloss Coating
ISO 8501-1
BS7079:A1
Sa 3
Sa 2.5
Sa 2
Sa 1
C St 2
D St 2
C St 3
D St 3
Swedish Std.
SIS055900
Sa 3
Sa 2.5
Sa 2
Sa 1
C St 2
D St 2
C St 3
D St 3
SSPC
SP 5
SP 10
SP 6
SP 7
SP 2
SP 2
SP 3
SP 3
NACE
1
2
3
4
-
(18-32)
(37-100)
10.0-18.0
1.5-4.0
(250-450)
(37-100)
1.5-4.0
(37-100)
2.0
1.5-4.0
(50)
(37-100)
Temperature:
50°F (10°C) minimum, 100°F (38°C)
maximum
(air, surface, and material)
At least 5°F (2.8°C) above dew point
1.5
1.5-4.0
(37.5)
(37-100)
Relative humidity:
85% maximum
Concrete/Masonry:
2 cts. Metalatex Semi-Gloss Coating
White Metal
Near White Metal
Commercial Blast
Brush-Off Blast
Hand Tool Cleaning Rusted
Pitted & Rusted
Power Tool Cleaning Rusted
Pitted & Rusted
0.7-1.3
1.5-4.0
Concrete Block:
1 ct. Heavy Duty Block Filler
2 cts. Metalatex Semi-Gloss Coating
Surface Preparation Standards
Condition of
Surface
TINTING
Tint with BAC, CCE, or EnviroToner at 100% tint strength, using
the respective tinting formula pages. Better performance will be
achieved with EnviroToners. Five minutes minimum mixing on a
mechanical shaker is required for complete mixing of color.
APPLICATION CONDITIONS
Wood, exterior:
1 ct. A-100 Exterior Oil Wood Primer
2 cts. Metalatex Semi-Gloss Coating
Wood, interior:
1 ct. PrepRite Wall & Wood Primer
2 cts. Metalatex Semi-Gloss Coating
Refer to product Application Bulletin for detailed application information.
Dry wall Interior:
1 ct. Prep Rite 200 Latex Primer B28W200 1.0-1.5
2 cts. Metalatex Semi-Gloss Coating
1.5-4.0
(25-37)
(37-100)
ORDERING INFORMATION
Packaging:
Weight:
1 (3.78L) and 5 gallon (18.9L) containers
May vary by color.
10.3 ± 0.2 lb/gl 1.24 kg/L
SAFETY PRECAUTIONS
Refer to the MSDS sheet before use.
The systems listed above are representative of the product's use,
other systems may be appropriate.
Published technical data and instructions are subject to change without notice.
Contact your Sherwin-Williams representative for additional technical data and
instructions.
WARRANTY
DISCLAIMER
The information and recommendations set forth in this Product Data Sheet are
based upon tests conducted by or on behalf of The Sherwin-Williams Company.
Such information and recommendations set forth herein are subject to change and
pertain to the product offered at the time of publication. Consult your SherwinWilliams representative to obtain the most recent Product Data Information and
Application Bulletin.
The Sherwin-Williams Company warrants our products to be free of manufacturing defects in accord with applicable Sherwin-Williams quality control procedures.
Liability for products proven defective, if any, is limited to replacement of the defective product or the refund of the purchase price paid for the defective product as
determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
www.sherwin-williams.com/protective
METALATEX®
Protective
&
Marine
Coatings
SEMI-GLOSS COATING
B42 SERIES
APPLICATION BULLETIN
Revised: March 27, 2014
1.10
APPLICATION CONDITIONS
SURFACE PREPARATIONS
Temperature:
50°F (10°C) minimum, 100°F (38°C)
maximum
(air, surface, and material)
At least 5°F (2.8°C) above dew point
Relative humidity:
85% maximum
Surface must be clean, dry, and in sound condition. Remove all
oil, dust, grease, dirt, loose rust, and other foreign material to
ensure adequate adhesion.
Do not use hydrocarbon solvents for cleaning.
Iron & Steel
Minimum surface preparation is Hand Tool Clean per SSPC-SP2.
Remove all oil and grease from surface per SSPC-SP1. For better
performance, use Commercial Blast Cleaning per SSPC-SP6.
Primer required.
Aluminum
Remove all oil and grease per SSPC-SP1. Self-priming.
Galvanizing
The surface should be weathered for 6 months prior to painting.
Remove all oil and grease per SSPC-SP1. Rusty galvanizing requires a minimum of Hand Tool Cleaning per SSPC-SP2 Prime
the area the same day as cleaned, with Pro-Cryl Primer,.
Concrete and Masonry
For surface preparation, refer to SSPC-SP13/NACE 6 or ICRI No.
310.2, CSP 1-3. Surfaces should be thoroughly cleaned and dry.
Surface temperatures must be at least 55°F (13°C) before filling.
Use Heavy Duty Block Filler, B42W46. Filler must be thoroughly
dry before topcoating per manufacturer's recommendations.
Wood
Surface must be clean, dry and sound. Prime with recommended
primer. No painting should be done immediately after a rain or
during foggy weather. Knots and pitch streaks must be scraped,
sanded and spot primed before full coat of primer is applied. All
nail holes or small openings must be properly caulked.
Previously Painted Surfaces
If in sound condition, clean the surface of all foreign material.
Smooth, hard or glossy coatings and surfaces should be dulled
by abrading the surface. Apply a test area, allowing paint to dry
one week before testing adhesion. If adhesion is poor, additional
abrasion of the surface and/or removal of the previous coating may
be necessary. Retest surface for adhesion. If paint is peeling or
badly weathered, clean surface to sound substrate and treat as a
new surface as above.
APPLICATION EQUIPMENT
The following is a guide. Changes in pressures and tip sizes may
be needed for proper spray characteristics. Always purge spray
equipment before use with listed reducer. Any reduction must be
compliant with existing VOC regulations and compatible with the
existing environmental and application conditions.
Reducer/Clean Up ...........Water
Airless Spray
Pressure.........................2500 psi
Hose...............................1/4" ID
Tip ...................................015"
Filter ...............................60 mesh
Reduction .......................As needed up to 12½% by volume
Conventional Spray
Gun ................................Binks 95
Fluid Nozzle ...................66
Air Nozzle.......................63 PB
Atomization Pressure .....50 psi
Fluid Pressure ................20-50 psi
Reduction .......................As needed up to 12½% by volume
Brush
Brush..............................Nylon / polyester
Reduction .......................Not recommended
Roller
Cover .............................3/8" woven solvent resistant core
Reduction .......................Not recommended
If specific application equipment is not listed above, equivalent
equipment may be substituted.
FRP/PVC - Clean, Dry, Sand/Abrade
Surface Preparation Standards
Condition of
Surface
White Metal
Near White Metal
Commercial Blast
Brush-Off Blast
Hand Tool Cleaning Rusted
Pitted & Rusted
Power Tool Cleaning Rusted
Pitted & Rusted
ISO 8501-1
BS7079:A1
Sa 3
Sa 2.5
Sa 2
Sa 1
C St 2
D St 2
C St 3
D St 3
Swedish Std.
SIS055900
Sa 3
Sa 2.5
Sa 2
Sa 1
C St 2
D St 2
C St 3
D St 3
SSPC
SP 5
SP 10
SP 6
SP 7
SP 2
SP 2
SP 3
SP 3
NACE
1
2
3
4
-
www.sherwin-williams.com/protective
continued on back
METALATEX®
Protective
&
Marine
Coatings
SEMI-GLOSS COATING
B42 SERIES
APPLICATION BULLETIN
APPLICATION PROCEDURES
1.10
PERFORMANCE TIPS
Surface preparation must be completed as indicated.
Stripe coat all crevices, welds, and sharp angles to prevent early
failure in these areas.
Mixing Instructions: Mix paint thoroughly to a uniform consistency When using spray application, use a 50% overlap with each pass
with low speed power agitation prior to use.
of the gun to avoid holidays, bare areas, and pinholes. If necessary,
Apply paint at the recommended film thickness and spreading cross spray at a right angle
rate as indicated below:
During the early stages of drying, the coating is sensitive to rain,
dew, high humidity, and moisture condensation. Plan painting
Recommended Spreading Rate per coat:
schedules to avoid these influences during the first 16-24 hours
of curing.
Minimum
Maximum
Wet mils (microns)
Dry mils (microns)
~Coverage sq ft/gal (m2/L)
4.0 (100)
1.5 (37)
150 (3.7)
11.0 (275)
4.0 (100)
395 (9.7)
Theoretical coverage sq ft/gal
608 (14.9)
(m2/L) @ 1 mil / 25 microns dft
NOTE: Brush or roll application may require multiple coats to
achieve maximum film thickness and uniformity of appearance.
Drying Schedule @ 4.0 mils wet (100 microns):
To touch:
To handle:
To recoat:
To cure:
@ 55°F/13°C
@ 77°F/25°C
50% RH
@ 100°F/38°C
3 hours
7 hours
18 hours
30 days
30 minutes
1 hour
4 hours
20 days
10 minutes
1 hour
3 hours
10 days
Spreading rates are calculated on volume solids and do not include
an application loss factor due to surface profile, roughness or porosity of the surface, skill and technique of the applicator, method
of application, various surface irregularities, material lost during
mixing, spillage, overthinning, climatic conditions, and excessive
film build.
Excessive reduction of material can affect film build, appearance,
and adhesion.
Do not use hydrocarbon solvents for cleaning.
Drying time is temperature, humidity, and film thickness dependent.
Application of coating above maximum or below minimum
recommended spreading rate may adversely affect coating
performance.
Refer to Product Information sheet for additional performance
characteristics and properties.
SAFETY PRECAUTIONS
CLEAN UP INSTRUCTIONS
Refer to the MSDS sheet before use.
Clean spills and spatters immediately with soap and warm water.
Clean hands and tools immediately after use with soap and warm
water. After cleaning, flush spray equipment with Mineral Spirits
to prevent rusting of the equipment. Follow manufacturer's safety
recommendations when using Mineral Spirits.
DISCLAIMER
The information and recommendations set forth in this Product Data Sheet are
based upon tests conducted by or on behalf of The Sherwin-Williams Company.
Such information and recommendations set forth herein are subject to change and
pertain to the product offered at the time of publication. Consult your SherwinWilliams representative to obtain the most recent Product Data Information and
Application Bulletin.
Published technical data and instructions are subject to change without notice.
Contact your Sherwin-Williams representative for additional technical data and
instructions.
WARRANTY
The Sherwin-Williams Company warrants our products to be free of manufacturing
defects in accord with applicable Sherwin-Williams quality control procedures.
Liability for products proven defective, if any, is limited to replacement of the defective product or the refund of the purchase price paid for the defective product
as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
www.sherwin-williams.com/protective
Material Safety Data Sheets
MATERIAL SAFETY DATA SHEET
C1520006
04 00
DATE OF PREPARATION
Jun 10, 2014
SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION
PRODUCT NUMBER
C1520006
PRODUCT NAME
Comex® ULTRA TECH Interior Latex Multi-Solution Primer/Sealer, White
MANUFACTURER'S NAME
Comex Family of Brands
5575 DTC Parkway, Suite 100
Greenwood Village, CO 80111
Telephone Numbers and Websites
Product Information (800) 383-8406
Regulatory Information (216) 566-2902
Medical Emergency (216) 566-2917
Transportation Emergency* (800) 424-9300
*for Chemical Emergency ONLY (spill, leak, fire, exposure, or
accident)
SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS
% by Weight
4
5
9
CAS Number
14807-96-6
1317-65-3
13463-67-7
Ingredient
Talc
ACGIH TLV
OSHA PEL
Calcium Carbonate
ACGIH TLV
OSHA PEL
OSHA PEL
Titanium Dioxide
ACGIH TLV
OSHA PEL
OSHA PEL
Units
Vapor Pressure
2 mg/m3 as Resp. Dust
2 mg/m3 as Resp. Dust
10 mg/m3 as Dust
10 mg/m3 Total Dust
5 mg/m3 Respirable Fraction
10 mg/m3 as Dust
10 mg/m3 Total Dust
5 mg/m3 Respirable Fraction
SECTION 3 — HAZARDS IDENTIFICATION
ROUTES OF EXPOSURE
INHALATION of vapor or spray mist.
EYE or SKIN contact with the product, vapor or spray mist.
EFFECTS OF OVEREXPOSURE
EYES: Irritation.
SKIN: Prolonged or repeated exposure may cause irritation.
INHALATION: Irritation of the upper respiratory system.
HMIS Codes
Health 1*
Flammability 0
Reactivity 0
SIGNS AND SYMPTOMS OF OVEREXPOSURE
Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
None generally recognized.
CANCER INFORMATION
For complete discussion of toxicology data refer to Section 11.
SECTION 4 — FIRST AID MEASURES
EYES:
SKIN:
INHALATION:
INGESTION:
Flush eyes with large amounts of water for 15 minutes. Get medical attention.
Wash affected area thoroughly with soap and water.
If affected, remove from exposure. Restore breathing. Keep warm and quiet.
Do not induce vomiting. Get medical attention immediately.
page 1 of 4
C1520006
SECTION 5 — FIRE FIGHTING MEASURES
FLASH POINT
Not Applicable
LEL
UEL
FLAMMABILITY CLASSIFICATION
Not
Not
Not Applicable
Applicable
Applicable
EXTINGUISHING MEDIA
Carbon Dioxide, Dry Chemical, Alcohol Foam
UNUSUAL FIRE AND EXPLOSION HAZARDS
Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
apparent. Obtain medical attention.
SPECIAL FIRE FIGHTING PROCEDURES
Full protective equipment including self-contained breathing apparatus should be used.
Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
build-up and possible autoignition or explosion when exposed to extreme heat.
SECTION 6 — ACCIDENTAL RELEASE MEASURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
Remove all sources of ignition. Ventilate the area.
Remove with inert absorbent.
SECTION 7 — HANDLING AND STORAGE
STORAGE CATEGORY
Not Applicable
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
Keep out of the reach of children.
SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION
PRECAUTIONS TO BE TAKEN IN USE
Use only with adequate ventilation.
Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
Wash hands after using.
This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous
levels only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts
are ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your
local health authority.
VENTILATION
Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure
limits. Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
RESPIRATORY PROTECTION
If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
approved by NIOSH/MSHA for protection against materials in Section 2.
When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
product, underlying paint, or the abrasive.
PROTECTIVE GLOVES
Required for long or repeated contact.
EYE PROTECTION
Wear safety spectacles with unperforated sideshields.
page 2 of 4
C1520006
SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES
10.38 lb/gal
1243 g/l
1.25
212 - 213 °F
100 - 100 °C
Not Available
72%
Slower than
ether
VAPOR DENSITY Heavier than air
SOLUBILITY IN WATER Not Available
pH 9.0
VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
0.31 lb/gal
37 g/l Less Water and Federally Exempt Solvents
0.08 lb/gal
10 g/l Emitted VOC
PRODUCT WEIGHT
SPECIFIC GRAVITY
BOILING POINT
MELTING POINT
VOLATILE VOLUME
EVAPORATION RATE
SECTION 10 — STABILITY AND REACTIVITY
STABILITY — Stable
CONDITIONS TO AVOID
None known.
INCOMPATIBILITY
None known.
HAZARDOUS DECOMPOSITION PRODUCTS
By fire: Carbon Dioxide, Carbon Monoxide
HAZARDOUS POLYMERIZATION
Will not occur
SECTION 11 — TOXICOLOGICAL INFORMATION
CHRONIC HEALTH HAZARDS
IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such
as paint."
TOXICOLOGY DATA
CAS No.
Ingredient Name
14807-96-6
Talc
LC50 RAT
4HR
Not Available
LD50 RAT
Not Available
1317-65-3
Calcium Carbonate
LC50 RAT
4HR
Not Available
LD50 RAT
Not Available
13463-67-7
Titanium Dioxide
LC50 RAT
4HR
Not Available
LD50 RAT
Not Available
SECTION 12 — ECOLOGICAL INFORMATION
ECOTOXICOLOGICAL INFORMATION
No data available.
SECTION 13 — DISPOSAL CONSIDERATIONS
WASTE DISPOSAL METHOD
Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
regulations regarding pollution.
SECTION 14 — TRANSPORT INFORMATION
Multi-modal shipping descriptions are provided for informational purposes and do not consider container sizes. The presence of a shipping
description for a particular mode of transport (ocean, air, etc.), does not indicate that the product is packaged suitably for that mode of
transport. All packaging must be reviewed for suitability prior to shipment, and compliance with the applicable regulations is the sole
responsibility of the person offering the product for transport.
page 3 of 4
C1520006
US Ground (DOT)
Not Regulated for Transportation.
Canada (TDG)
Not Regulated for Transportation.
IMO
Not Regulated for Transportation.
IATA/ICAO
Not Regulated for Transportation.
SECTION 15 — REGULATORY INFORMATION
SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
CAS No.
CHEMICAL/COMPOUND
% by WT
% Element
No ingredients in this product are subject to SARA 313 (40 CFR 372.65C) Supplier Notification.
CALIFORNIA PROPOSITION 65
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
TSCA CERTIFICATION
All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.
SECTION 16 — OTHER INFORMATION
This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
MSDS contains all of the information required by the CPR.
The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
warranties, express or implied, and assume no liability in connection with any use of this information.
page 4 of 4
MATERIAL SAFETY DATA SHEET
C1360001
02 00
DATE OF PREPARATION
Mar 18, 2014
SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION
PRODUCT NUMBER
C1360001
PRODUCT NAME
Comex® ULTRA TECH Interior Latex Zero-VOC/Low Odor Semi-Gloss Paint, White Base
MANUFACTURER'S NAME
Comex Family of Brands
5575 DTC Parkway, Suite 100
Greenwood Village, CO 80111
Telephone Numbers and Websites
Product Information (800) 383-8406
Regulatory Information (216) 566-2902
Medical Emergency (216) 566-2917
Transportation Emergency* (800) 424-9300
*for Chemical Emergency ONLY (spill, leak, fire, exposure, or
accident)
SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS
% by Weight
2
19
CAS Number
1332-58-7
13463-67-7
Ingredient
Kaolin
ACGIH TLV
OSHA PEL
OSHA PEL
Titanium Dioxide
ACGIH TLV
OSHA PEL
OSHA PEL
Units
Vapor Pressure
2 mg/m3 as Resp. Dust
10 mg/m3 Total Dust
5 mg/m3 Respirable Fraction
10 mg/m3 as Dust
10 mg/m3 Total Dust
5 mg/m3 Respirable Fraction
SECTION 3 — HAZARDS IDENTIFICATION
ROUTES OF EXPOSURE
INHALATION of vapor or spray mist.
EYE or SKIN contact with the product, vapor or spray mist.
EFFECTS OF OVEREXPOSURE
EYES: Irritation.
SKIN: Prolonged or repeated exposure may cause irritation.
INHALATION: Irritation of the upper respiratory system.
HMIS Codes
Health 1*
Flammability 0
Reactivity 0
SIGNS AND SYMPTOMS OF OVEREXPOSURE
Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
None generally recognized.
CANCER INFORMATION
For complete discussion of toxicology data refer to Section 11.
SECTION 4 — FIRST AID MEASURES
EYES:
SKIN:
INHALATION:
INGESTION:
Flush eyes with large amounts of water for 15 minutes. Get medical attention.
Wash affected area thoroughly with soap and water.
If affected, remove from exposure. Restore breathing. Keep warm and quiet.
Do not induce vomiting. Get medical attention immediately.
SECTION 5 — FIRE FIGHTING MEASURES
page 1 of 4
C1360001
FLASH POINT
Not Applicable
LEL
UEL
FLAMMABILITY CLASSIFICATION
Not
Not
Not Applicable
Applicable
Applicable
EXTINGUISHING MEDIA
Carbon Dioxide, Dry Chemical, Alcohol Foam
UNUSUAL FIRE AND EXPLOSION HAZARDS
Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
apparent. Obtain medical attention.
SPECIAL FIRE FIGHTING PROCEDURES
Full protective equipment including self-contained breathing apparatus should be used.
Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
build-up and possible autoignition or explosion when exposed to extreme heat.
SECTION 6 — ACCIDENTAL RELEASE MEASURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
Remove all sources of ignition. Ventilate the area.
Remove with inert absorbent.
SECTION 7 — HANDLING AND STORAGE
STORAGE CATEGORY
Not Applicable
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
Keep out of the reach of children.
SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION
PRECAUTIONS TO BE TAKEN IN USE
Use only with adequate ventilation.
Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
Wash hands after using.
This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous
levels only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts
are ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your
local health authority.
VENTILATION
Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure
limits. Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
RESPIRATORY PROTECTION
If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
approved by NIOSH/MSHA for protection against materials in Section 2.
When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
product, underlying paint, or the abrasive.
PROTECTIVE GLOVES
Required for long or repeated contact.
EYE PROTECTION
Wear safety spectacles with unperforated sideshields.
SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES
10.23 lb/gal
1226 g/l
1.23
212 - 213 °F
100 - 100 °C
Not Available
64%
Slower than
ether
VAPOR DENSITY Heavier than air
SOLUBILITY IN WATER Not Available
pH 9.0
VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
0.09 lb/gal
11 g/l Less Water and Federally Exempt Solvents
0.03 lb/gal
4 g/l Emitted VOC
PRODUCT WEIGHT
SPECIFIC GRAVITY
BOILING POINT
MELTING POINT
VOLATILE VOLUME
EVAPORATION RATE
page 2 of 4
C1360001
SECTION 10 — STABILITY AND REACTIVITY
STABILITY — Stable
CONDITIONS TO AVOID
None known.
INCOMPATIBILITY
None known.
HAZARDOUS DECOMPOSITION PRODUCTS
By fire: Carbon Dioxide, Carbon Monoxide
HAZARDOUS POLYMERIZATION
Will not occur
SECTION 11 — TOXICOLOGICAL INFORMATION
CHRONIC HEALTH HAZARDS
IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such
as paint."
TOXICOLOGY DATA
CAS No.
Ingredient Name
1332-58-7
Kaolin
LC50 RAT
4HR
Not Available
LD50 RAT
Not Available
13463-67-7
Titanium Dioxide
LC50 RAT
4HR
Not Available
LD50 RAT
Not Available
SECTION 12 — ECOLOGICAL INFORMATION
ECOTOXICOLOGICAL INFORMATION
No data available.
SECTION 13 — DISPOSAL CONSIDERATIONS
WASTE DISPOSAL METHOD
Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
regulations regarding pollution.
SECTION 14 — TRANSPORT INFORMATION
Multi-modal shipping descriptions are provided for informational purposes and do not consider container sizes. The presence of a shipping
description for a particular mode of transport (ocean, air, etc.), does not indicate that the product is packaged suitably for that mode of
transport. All packaging must be reviewed for suitability prior to shipment, and compliance with the applicable regulations is the sole
responsibility of the person offering the product for transport.
US Ground (DOT)
Not Regulated for Transportation.
DOT (Dept of Transportation) Hazardous Substances & Reportable Quantities
Carbendazim 10 lb RQ
Canada (TDG)
Not Regulated for Transportation.
IMO
Not Regulated for Transportation.
IATA/ICAO
Not Regulated for Transportation.
SECTION 15 — REGULATORY INFORMATION
SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
CAS No.
CHEMICAL/COMPOUND
% by WT
% Element
No ingredients in this product are subject to SARA 313 (40 CFR 372.65C) Supplier Notification.
CALIFORNIA PROPOSITION 65
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
TSCA CERTIFICATION
All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.
page 3 of 4
C1360001
SECTION 16 — OTHER INFORMATION
This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
MSDS contains all of the information required by the CPR.
The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
warranties, express or implied, and assume no liability in connection with any use of this information.
page 4 of 4
MATERIAL SAFETY DATA SHEET
C3020006
04 00
DATE OF PREPARATION
Mar 20, 2014
SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION
PRODUCT NUMBER
C3020006
PRODUCT NAME
Comex® ULTRA TECH 100% Acrylic Block Filler - Interior & Exterior, White
MANUFACTURER'S NAME
Comex Family of Brands
5575 DTC Parkway, Suite 100
Greenwood Village, CO 80111
Telephone Numbers and Websites
Product Information (800) 383-8406
Regulatory Information (216) 566-2902
Medical Emergency (216) 566-2917
Transportation Emergency* (800) 424-9300
*for Chemical Emergency ONLY (spill, leak, fire, exposure, or
accident)
SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS
% by Weight
4
27
2
CAS Number
14807-96-6
1317-65-3
13463-67-7
Ingredient
Talc
ACGIH TLV
OSHA PEL
Calcium Carbonate
ACGIH TLV
OSHA PEL
Titanium Dioxide
ACGIH TLV
OSHA PEL
OSHA PEL
Units
Vapor Pressure
2 mg/m3 as Resp. Dust
2 mg/m3 as Resp. Dust
10 mg/m3 as Dust
15 mg/m3 as Dust
10 mg/m3 as Dust
10 mg/m3 Total Dust
5 mg/m3 Respirable Fraction
SECTION 3 — HAZARDS IDENTIFICATION
ROUTES OF EXPOSURE
INHALATION of vapor or spray mist.
EYE or SKIN contact with the product, vapor or spray mist.
EFFECTS OF OVEREXPOSURE
EYES: Irritation.
SKIN: Prolonged or repeated exposure may cause irritation.
INHALATION: Irritation of the upper respiratory system.
HMIS Codes
Health 1*
Flammability 0
Reactivity 0
In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
None generally recognized.
CANCER INFORMATION
For complete discussion of toxicology data refer to Section 11.
SECTION 4 — FIRST AID MEASURES
EYES:
SKIN:
INHALATION:
INGESTION:
Flush eyes with large amounts of water for 15 minutes. Get medical attention.
Wash affected area thoroughly with soap and water.
Remove contaminated clothing and launder before re-use.
If affected, remove from exposure. Restore breathing. Keep warm and quiet.
Do not induce vomiting. Get medical attention immediately.
page 1 of 4
C3020006
SECTION 5 — FIRE FIGHTING MEASURES
FLASH POINT
Not Applicable
LEL
UEL
FLAMMABILITY CLASSIFICATION
Not
Not
Not Applicable
Applicable
Applicable
EXTINGUISHING MEDIA
Carbon Dioxide, Dry Chemical, Alcohol Foam
UNUSUAL FIRE AND EXPLOSION HAZARDS
Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
apparent. Obtain medical attention.
SPECIAL FIRE FIGHTING PROCEDURES
Full protective equipment including self-contained breathing apparatus should be used.
Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
build-up and possible autoignition or explosion when exposed to extreme heat.
SECTION 6 — ACCIDENTAL RELEASE MEASURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
Remove all sources of ignition. Ventilate the area.
Remove with inert absorbent.
SECTION 7 — HANDLING AND STORAGE
STORAGE CATEGORY
Not Applicable
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
Keep out of the reach of children.
SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION
PRECAUTIONS TO BE TAKEN IN USE
Use only with adequate ventilation.
Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
Wash hands after using.
This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous
levels only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts
are ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your
local health authority.
VENTILATION
Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure
limits. Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
RESPIRATORY PROTECTION
If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
approved by NIOSH/MSHA for protection against materials in Section 2.
When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
product, underlying paint, or the abrasive.
PROTECTIVE GLOVES
Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
EYE PROTECTION
Wear safety spectacles with unperforated sideshields.
page 2 of 4
C3020006
SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES
13.29 lb/gal
1592 g/l
1.60
212 - 213 °F
100 - 100 °C
Not Available
51%
Slower than
ether
VAPOR DENSITY Heavier than air
SOLUBILITY IN WATER Not Available
pH 9.0
VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
0.41 lb/gal
49 g/l Less Water and Federally Exempt Solvents
0.21 lb/gal
25 g/l Emitted VOC
PRODUCT WEIGHT
SPECIFIC GRAVITY
BOILING POINT
MELTING POINT
VOLATILE VOLUME
EVAPORATION RATE
SECTION 10 — STABILITY AND REACTIVITY
STABILITY — Stable
CONDITIONS TO AVOID
None known.
INCOMPATIBILITY
None known.
HAZARDOUS DECOMPOSITION PRODUCTS
By fire: Carbon Dioxide, Carbon Monoxide
HAZARDOUS POLYMERIZATION
Will not occur
SECTION 11 — TOXICOLOGICAL INFORMATION
CHRONIC HEALTH HAZARDS
IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such
as paint."
TOXICOLOGY DATA
CAS No.
Ingredient Name
14807-96-6
Talc
LC50 RAT
4HR
Not Available
LD50 RAT
Not Available
1317-65-3
Calcium Carbonate
LC50 RAT
4HR
Not Available
LD50 RAT
Not Available
13463-67-7
Titanium Dioxide
LC50 RAT
4HR
Not Available
LD50 RAT
Not Available
SECTION 12 — ECOLOGICAL INFORMATION
ECOTOXICOLOGICAL INFORMATION
No data available.
SECTION 13 — DISPOSAL CONSIDERATIONS
WASTE DISPOSAL METHOD
Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
regulations regarding pollution.
SECTION 14 — TRANSPORT INFORMATION
Multi-modal shipping descriptions are provided for informational purposes and do not consider container sizes. The presence of a shipping
description for a particular mode of transport (ocean, air, etc.), does not indicate that the product is packaged suitably for that mode of
transport. All packaging must be reviewed for suitability prior to shipment, and compliance with the applicable regulations is the sole
responsibility of the person offering the product for transport.
page 3 of 4
C3020006
US Ground (DOT)
Not Regulated for Transportation.
Canada (TDG)
Not Regulated for Transportation.
IMO
Not Regulated for Transportation.
IATA/ICAO
Not Regulated for Transportation.
SECTION 15 — REGULATORY INFORMATION
SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
CAS No.
CHEMICAL/COMPOUND
% by WT
% Element
No ingredients in this product are subject to SARA 313 (40 CFR 372.65C) Supplier Notification.
CALIFORNIA PROPOSITION 65
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
TSCA CERTIFICATION
All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.
SECTION 16 — OTHER INFORMATION
This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
MSDS contains all of the information required by the CPR.
The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
warranties, express or implied, and assume no liability in connection with any use of this information.
page 4 of 4
MATERIAL SAFETY DATA SHEET
B42W111
25 00
DATE OF PREPARATION
Mar 8, 2014
SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION
PRODUCT NUMBER
B42W111
PRODUCT NAME
METALATEX® Semi-Gloss Acrylic Coating, Extra White
MANUFACTURER'S NAME
THE SHERWIN-WILLIAMS COMPANY
101 Prospect Avenue N.W.
Cleveland, OH 44115
Telephone Numbers and Websites
Product Information
(800) 524-5979
www.sherwin-williams.com
Regulatory Information (216) 566-2902
www.paintdocs.com
Medical Emergency (216) 566-2917
Transportation Emergency* (800) 424-9300
*for Chemical Emergency ONLY (spill, leak, fire, exposure, or
accident)
SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS
% by Weight
1
13
CAS Number
112-34-5
13463-67-7
Ingredient
Units
2-(2-Butoxyethoxy)-ethanol
ACGIH TLV
OSHA PEL
Titanium Dioxide
ACGIH TLV
10
OSHA PEL
10
OSHA PEL
5
Vapor Pressure
Not Available
Not Available
0.06 mm
mg/m3 as Dust
mg/m3 Total Dust
mg/m3 Respirable Fraction
SECTION 3 — HAZARDS IDENTIFICATION
ROUTES OF EXPOSURE
INHALATION of vapor or spray mist.
EYE or SKIN contact with the product, vapor or spray mist.
EFFECTS OF OVEREXPOSURE
EYES: Irritation.
SKIN: Prolonged or repeated exposure may cause irritation.
INHALATION: Irritation of the upper respiratory system.
HMIS Codes
Health 2*
Flammability 0
Reactivity 0
In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
None generally recognized.
CANCER INFORMATION
For complete discussion of toxicology data refer to Section 11.
SECTION 4 — FIRST AID MEASURES
EYES:
SKIN:
INHALATION:
INGESTION:
Flush eyes with large amounts of water for 15 minutes. Get medical attention.
Wash affected area thoroughly with soap and water.
Remove contaminated clothing and launder before re-use.
If affected, remove from exposure. Restore breathing. Keep warm and quiet.
Do not induce vomiting. Get medical attention immediately.
page 1 of 4
B42W111
SECTION 5 — FIRE FIGHTING MEASURES
FLASH POINT
Not Applicable
LEL
UEL
FLAMMABILITY CLASSIFICATION
Not
Not
Not Applicable
Applicable
Applicable
EXTINGUISHING MEDIA
Carbon Dioxide, Dry Chemical, Alcohol Foam
UNUSUAL FIRE AND EXPLOSION HAZARDS
Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
apparent. Obtain medical attention.
SPECIAL FIRE FIGHTING PROCEDURES
Full protective equipment including self-contained breathing apparatus should be used.
Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
build-up and possible autoignition or explosion when exposed to extreme heat.
SECTION 6 — ACCIDENTAL RELEASE MEASURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
Remove all sources of ignition. Ventilate the area.
Remove with inert absorbent.
SECTION 7 — HANDLING AND STORAGE
STORAGE CATEGORY
Not Applicable
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
Keep out of the reach of children.
SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION
PRECAUTIONS TO BE TAKEN IN USE
Use only with adequate ventilation.
Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
Wash hands after using.
This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous
levels only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts
are ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
VENTILATION
Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure
limits. Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
RESPIRATORY PROTECTION
If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
approved by NIOSH/MSHA for protection against materials in Section 2.
When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
product, underlying paint, or the abrasive.
PROTECTIVE GLOVES
Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
EYE PROTECTION
Wear safety spectacles with unperforated sideshields.
SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES
9.69 lb/gal
1161 g/l
1.17
212 - 448 °F
100 - 231 °C
Not Available
62%
Slower than
ether
VAPOR DENSITY Heavier than air
SOLUBILITY IN WATER Not Available
pH 9.5
VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
0.39 lb/gal
47 g/l Less Water and Federally Exempt Solvents
0.15 lb/gal
18 g/l Emitted VOC
PRODUCT WEIGHT
SPECIFIC GRAVITY
BOILING POINT
MELTING POINT
VOLATILE VOLUME
EVAPORATION RATE
page 2 of 4
B42W111
SECTION 10 — STABILITY AND REACTIVITY
STABILITY — Stable
CONDITIONS TO AVOID
None known.
INCOMPATIBILITY
None known.
HAZARDOUS DECOMPOSITION PRODUCTS
By fire: Carbon Dioxide, Carbon Monoxide
HAZARDOUS POLYMERIZATION
Will not occur
SECTION 11 — TOXICOLOGICAL INFORMATION
CHRONIC HEALTH HAZARDS
IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such
as paint."
TOXICOLOGY DATA
CAS No.
Ingredient Name
112-34-5
2-(2-Butoxyethoxy)-ethanol
LC50 RAT
4HR
Not Available
LD50 RAT
5660 mg/kg
13463-67-7
Titanium Dioxide
LC50 RAT
4HR
Not Available
LD50 RAT
Not Available
SECTION 12 — ECOLOGICAL INFORMATION
ECOTOXICOLOGICAL INFORMATION
No data available.
SECTION 13 — DISPOSAL CONSIDERATIONS
WASTE DISPOSAL METHOD
Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
regulations regarding pollution.
SECTION 14 — TRANSPORT INFORMATION
Multi-modal shipping descriptions are provided for informational purposes and do not consider container sizes. The presence of a shipping
description for a particular mode of transport (ocean, air, etc.), does not indicate that the product is packaged suitably for that mode of
transport. All packaging must be reviewed for suitability prior to shipment, and compliance with the applicable regulations is the sole
responsibility of the person offering the product for transport.
US Ground (DOT)
Not Regulated for Transportation.
Canada (TDG)
Not Regulated for Transportation.
IMO
Not Regulated for Transportation.
IATA/ICAO
Not Regulated for Transportation.
SECTION 15 — REGULATORY INFORMATION
SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
CAS No.
CHEMICAL/COMPOUND
% by WT
% Element
Glycol Ethers
2
CALIFORNIA PROPOSITION 65
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
TSCA CERTIFICATION
All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.
page 3 of 4
B42W111
SECTION 16 — OTHER INFORMATION
This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
MSDS contains all of the information required by the CPR.
The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
warranties, express or implied, and assume no liability in connection with any use of this information.
page 4 of 4