SOLID SAWN ROOF DECKING
Transcription
SOLID SAWN ROOF DECKING
SOLID SAWN ROOF DECKING Center-Matched and End-Matched with Sanded Face ALSO AVAILABLE Square Edge Rough Sawn Bullnose Edge Specified Lengths SPECIFIED LENGTHS Structural Finger-Jointed Up to 24' %2,6(&$6&$'( WOOD ROOF & FLOOR DECKING LAMINATED & SOLID 6758&785$/:22'6 2 x 6" SOLID SAWN ROOF DECKING This facility also manufactures: Boise Cascade Engineered Wood Products known for quality structural wood products, now manufactures solid sawn roof decking in Douglas Fir/Larch and Alaskan yellow cedar (special order). Solid sawn decking is center and endmatched with a sanded face and kiln-dried to 15% moisture content and less. The decking is also available with a square edge, or bullnose edge and/or rough-sawn face in specified lengths up to 24 feet. The span tables for the solid sawn decking are shown here. For Alaskan Yellow Cedar in wet-use decking conditions, call Homedale sales for more information. Solid sawn decking serves as a structural load carrying unit and, combined with laminated beams and columns, provides a distinctive wood deck ceiling in the traditional timber style. • Laminated random length roof decking • Long length roof decking • Douglas Fir laminated wood beams • Alaskan yellow cedar laminated wood beams (special order). Service and Shipment Wood roof decking can be factory prefinished with a choice of Olympic, acrylic, or other proprietary stains to enhance the wood grain characteristics. All Homedale solid sawn decking is subject to strict quality controls. Orders can be shipped direct to the job site or to distribution yard facilities. For the name of your nearest distributor, contact us at 208.337.3134 or email Glulam@BC.com for the distributor nearest to you. Information is also available on our website at www.BC.com/ewp Pictured on cover: Alaskan Yellow Cedar wood roof decking on installation photo. Two Insets showing close-up center-matched and end-matched samples of Douglas fir/Larch solid sawn decking. Pictured above: Detail of Alaskan Yellow Cedar solid sawn decking. THERMAL INSULATION VALUES Allowable Uniform Roof Load (PSF)* Douglas Fir/Larch Alaskan Yellow Cedar E = 1,800,000 psi Fb = 2530 psi (CD = 1.15) SPAN FEET 2 3 4 5 6 7 8 9 10 11 12 SIMPLE SPAN L/180 PSF 1740 587 248 127 73 46 31 22 16 L/240 PSF 1480 440 186 95 55 35 23 16 12 CONTROLLED** RANDOM LAYUP L/180 L/240 PSF PSF 1450 1450 645 645 363 314 215 161 124 93 78 59 52 39 37 28 27 20 2-SPAN CONTINUOUS L/180 L/240 PSF PSF 1740 1740 775 775 436 436 279 229 177 133 111 83 75 56 52 39 38 29 29 22 22 17 E = 1,400,000 psi Fb = 1600 psi (CD = 1.15) SIMPLE SPAN L/180 PSF 1100 456 193 99 57 36 24 17 12 L/240 PSF 1100 342 144 74 43 27 18 13 9 CONTROLLED** RANDOM LAYUP L/180 L/240 PSF PSF 915 915 408 408 230 230 147 125 97 72 61 46 41 31 29 21 21 16 *Allowable uniform load is based on a load duration factor of 1.15 (snow) and dry service conditions. Effects of roof slope are not considered. Values do not take into consideration slight section loss due to tongue and groove profile, beveled edges, and other manufacturing details, which may reduce the section and resultant allowable values up to 2%. Long term deflection effects (creep) have not been taken into consideration in this table. For loads based on deflection of L/360 or L/480, use ½ of L/180 or L/240 values, respectively. **Controlled random layup — most economical system. Random deck is applied over three or more spans. Each piece must bear on at least one support beam or joist. All end-joints shall be end-matched. End joints in adjacent planks shall be at least two feet apart. The end spans shall have decking bearing on two supports for one out of three pieces of decking. %2,6(&$6&$'( WOOD ROOF & FLOOR DECKING LAMINATED & SOLID 6758&785$/:22'6 R-Value Decking Combined R-Value of Decking with 4" Rigid Insulation Douglas Fir/Larch 2" 1.9 31.9 Alaska Yellow Cedar 2" 2.2 32.2 1. R-values based on published 4" Polyisocyanurate rigid foam insulation values. 2. Published R-values may vary from each manufacturer. 3. For suggestions on other roof insulation configurations, please contact the Filler King® Sales Dept. 2-SPAN CONTINUOUS L/180 L/240 PSF PSF 1100 1100 490 490 276 276 176 176 122 103 87 65 58 43 41 31 30 22 22 17 17 13 ■ = loads controlled by bending Nominal Thickness ROOF DECKING WEIGHTS Douglas Fir/Larch Alaska Yellow Cedar Nominal Inches Lbs. per Sq. Ft. Lbs per MBF 2 4.0 1800 2 4.0 1800 SECTION PROPERTIES PER FOOT OF DECK WIDTH Nominal Inches Actual Inches I - In.4 S - In.3 A - In.2 2 17/16 2.97 4.14 17..26 *ROOF QUANTITY ESTIMATING FACTORS Nominal Inches Actual Sizes Inches Bd. Ft./ Sq. Ft. Bd. Ft./ Lineal Ft. 2x6 17/16 x 5 2.40 1.000 2x8 17/16 x 63/4 2.37 1.334 *EXAMPLE: 10,000 sq. ft. of roof deck x 2.4 equals 24,000 bd. ft. of 2 x 6 deck. Add a trim waste factor per job conditions. PO Box 185 • 4318 Pioneer Rd. Homedale, ID 83628 T 208.337.3134 • F 208.337.3139 800.237.4013 www.BC.com/ewp Glulam@BC.com SOLID SAWN ROOF DECKING FLYER 11/2014