pREset Thrombectomy Device
Transcription
pREset Thrombectomy Device
pREset Thrombectomy Device When Time is Critical... Choose from the broadest range of devices for the treatment of acute ischemic stroke pREset Thrombectomy Device The Clock is ticking... pREset and pREset LITE - the right choice for acute thrombotic occlusions • pREset 4-20 and 6-30 for large thrombus load in carotid “T” and proximal MCA occlusions • NEW pREset LITE 4-20 and 3-20 for treatment of distal MCA occlusions • Unique proximal “ring” design ensures stable opening and reduced tapering when withdrawn • The helical slit maintains cell shape integrity and enables optimized radial force distribution Absolute radial force over usable length in Ø 2mm Absolute radial force over usable length in Ø 3mm pREset Thrombectomy Device When Time is Critical... Less Tapering can make the Difference. Unique proximal “ring” design ensures stable opening and reduced tapering when withdrawn The helical slit maintains cell shape integrity and enables optimized radial force distribution pREset Other Stent Retriever 50 y/o male with carotid “T” and M2 occlusion treated with pREset 6-30 and pREset LITE 4-20 Carotid “T” occlusion caused by a cervical ICA occlusion. (Cervical ICA already recanalized by stent angioplasty, images not shown.) Catheterization of M2 inferior branch. Recanalization with pREset 6-30. Carotid “T” fully recanalized. Occlusion of M2, already seen on initial MRA. Recanalization with pREset LITE 4-20. Angio post treatment. Case images by courtesy of: Dr. Wiebke Kurre, Katharinenhospital Stuttgart, Germany on cover, bottom: Dr. Sascha Prothmann, Klinikum rechts der Isar, TU Munich, Germany pREset Thrombectomy Device pREset Thrombectomy Device The broadest range of devices for the treatment of acute ischemic stroke pREset 6-30 pREset 4-20 pREset LITE 3-20 pREset LITE 4-20 Fits through 0.021“ MC Fits through 0.0165“ MC pREset A: Shaft Diameter [mm] B: Shaft Length [mm] C: Insertion Wire Length [mm] D: Marker Distance [mm] E: Working Length [mm] Min. ID Microcatheter [inch] Min. vessel diameter [mm] PRE-4-20 4 30 1800 1260 20 0.021 >2 PRE-6-30 6 48 1800 1275 30 0.021 >3 A: Shaft Diameter [mm] B: Shaft Length [mm] C: Insertion Wire Length [mm] D: Marker Distance [mm] E: Working Length [mm] Min. ID Microcatheter [inch] Min. vessel diameter [mm] PRE-LT-3-20 3 30 1800 1255 20 0.0165 >1.5 PRE-LT-4-20 4 30 1800 1255 20 0.0165 >1.5 REF pREset LITE REF phenox GmbH | Lise-Meitner-Allee 31 | D-44801 Bochum, Germany Tel: +49 (0) 234 - 36 919 - 0 | Fax: +49 (0) 234 - 36 919 - 19 www.phenox.net | info@phenox.info 0297 © 2015 phenox GmbH (KIF-0005D/2015-01-05)
Similar documents
p64 Flow Modulation Device
Case images in this brochure by courtesy of Prof. Dr. Pedro Lylyk, Clínica La Sagrada Familia, Buenos Aires, Argentina
More information