Product Catalog
Transcription
Product Catalog
Product Catalog 3-15 Table of Contents Product Profile......................................................................................................................................1 Customer Service..................................................................................................................................1 Tie-Down System Cinch Nut(CNX)....................................................................................................................................2 Bearing Plate Washer (BPW)..................................................................................................................3 Z-Rod (ZR)............................................................................................................................................4 Coupler (CNW)......................................................................................................................................5 Anchor Tie (AT).....................................................................................................................................6 Installation Instructions..........................................................................................................................7 Design Examples Introduction..........................................................................................................................................8 Quick Reference................................................................................................................................ 8-10 Component Capacities.........................................................................................................................11 Using USP Specifier™ Design Software............................................................................................. 12-13 Wood Member Compression Capacities Douglas Fir and Hem Fir.......................................................................................................................14 Spruce Pine Fir and Southern Pine........................................................................................................15 Concentric Ties CT & T2 ............................................................................................................................................16 Installation Instructions.........................................................................................................................16 Dimensions and Fasteners....................................................................................................................17 Allowable Loads...................................................................................................................................18 Rod Capacities ....................................................................................................................................19 Photos...............................................................................................................................................20 MiTek Builder Products Profile ............................................................................................................................................21 Hardy Frame® Shear Walls ................................................................................................................22 Hardy Frame® Special Moment Frame................................................................................................23 USP Structural Connectors.............................................................................................................24 Typical Details Tie-Down System.............................................................................................................................. 25-31 Concentric Ties....................................................................................................................................32 Product Profile Our mission is to provide the building industry with a simple, efficient, quality tie-down system with unparalleled customer service. The Z4 Tie-Down System is used in multi-story buildings to transfer uplift tension forces that result from earthquake and wind loading, to the foundation. The CNX Cinch Nut allows for easy, fast, and dependable onestep installation. Z4 Tie-Down Runs are engineered for maximum material and labor efficiency to provide the most economical system in the industry. The CNX Cinch Nut is a shrinkage take-up device that is evaluated under the IBC and the City of Los Angeles building codes and is accepted by building departments nation-wide. The CNX ability to perpetually “travel” down the length of the threaded rod allows it to compensate for natural shrinkage and settlement that occurs in wood buildings, therefore keeping connections of Tie-Down Runs tight to the floor framing members for the life of the building. The Z4 Tie-Down System with the CNX Cinch Nut is designed to limit story drifts of multi-story buildings and eliminate additional structural damage caused by loose connections in the floor framing. The system was designed following the Northridge Earthquake when the effects of wood shrinkage, building settlement, and other building deformation were shown to be factors contributing to damage. The Z4 design was the first in the industry to provide a continuous load path for uplift that perpetually adjusts its connections to the floor system as the building deforms. The Z4 Tie-Down System is engineered, tested, and code evaluated to perform. It continues to be an innovative leader in the multi-story building industry. MiTek Builder Products The CNX Cinch Nut and its application in the Z4 Tie-Down System is a MiTek Builder Product. Other MiTek Builder Products include the Hardy Frame® Shear Wall System and USP Structural Connectors®. For more information please visit: mitekbuilderproducts.com. Design, Technical and Customer Support We offer comprehensive technical support, design of tie-down systems to meet engineered loads and deliver products packaged and labeled for easy identification in the field. • For the Design Professional we provide pre-engineered standard runs as well as individual component capacities to design custom runs. We also offer turn-key, sealed designs when engineered loads are provided to us. • Building Officials confidently approve our systems because they assemble with code evaluated components that have an ESR listing. • For the installer, our products arrive on time and are packaged systematically for easy identification of parts and sequence of assembly. We offer typical installation details, immediate telephone support and personal training is available from a sales or customer service representative. 1 Tie-Down System Cinch Nut (CNX) The Z4 CNX-Series Cinch Nut is a shrinkage compensating take-up device that keeps connections of Tie-Down Runs tight to the floor framing members when shrinkage and compression of wood fibers occur. The Cinch Nut uses an internal self-ratcheting action that permits movement, or “travel” perpetually in one direction along the length of a threaded rod. When connected to the floor framing, the Cinch Nut travels down the Z-Rod with the building as it shrinks and compresses. The CNX Series Cinch Nut is available in 1/8 inch increments for installation with threaded rods that are 3/8 inch through 1-1/2 inch diameter. Z4-CNX 5 CNX-Series Advantages • Features perpetual ratcheting along the length of a threaded rod that is not limited like the energy stored in a spring loaded device. • Simple, one-time installation that does not require pin or screw activation after the building is loaded. • CNX models are matched to the rod diameter specified for optimal tolerances. Code Reports Connecting Rod Diameter (1/8" Increments) CNX-Series Cinch Nut BPW5, BPW6 Installation BPW7 and Larger Installation • ESR-2190 • LA City RR 25623 • Florida Building Code - Building • Florida Building Code Residential CINCH NUT (CNX) Model Number 1 Connecting Rod Diameter (in.) Allowable Load Capacity (lbs.) 2 Z4-CNX3 Z4-CNX4 Z4-CNX5 Z4-CNX6 Z4-CNX7 Z4-CNX8 Z4-CNX9 Z4-CNX10 Z4-CNX11 Z4-CNX12 3/8 1/2 5/8 3/4 7/8 1 1 1/8 1 1/4 1 3/8 1 1/2 5,175 9,205 14,065 16,940 28,185 29,285 42,335 54,190 51,095 82,835 2 1. All CNX models fit within a nominal 4” wall depth. 2. Cinch Nut allowable loads have been evaluated and approved in ICC-ES ESR-2190. Tie-Down System Bearing Plate Washer (BPW) Z4 Bearing Plate Washers (BPW) are the interface between the Tie-Down System and the level of the building being anchored to the foundation. As the floor system is pulled upward by shear wall over-turning forces, pressure is applied to the BPW/CNX assembly and transferred into the Z-Rod/ all thread rod (ATR). The required bearing area is based on the design uplift to minimize crushing of the wood and the plate thickness must be sufficient that bending does not limit the capacity of the system. The wood species is also a factor when sizing. The pounds per square inch (psi) of compression cannot exceed the allowable compression perpendicular to the grain of the wood species it is bearing on. Materials ASTM A36 Z4-BPW 17-6 Finish Powder coated finish in various colors for easy identification 6 inch Nominal Wall Thickness Bearing Capacity on DF-L Bearing Plate Washer (BPW) BEARING PLATE WASHER (BPW) 1 Dimensions (in.) Nominal Wall Model Number Width & Length Thickness 2 Hole Dia. Thickness (in.) (in.) (in.) (in.) Z4-BPW5 3x3 1/4 1-5/16˝ Z4-BPW6 3-1/4 x 3-3/8 3/8 Z4-BPW7 3-1/4 x 4-3/8 1/2 Z4-BPW9 3-1/4 x 5 5/8 4˝ Z4-BPW11 3-1/4 x 5-7/8 3/4 1-9/16˝ Z4-BPW15 3-1/4 x 7-7/8 7/8 Z4-BPW20 3-1/4 x 10-1/4 1-1/4 Z4-BPW25 3-1/2 x 11-3/4 1-1/2 Z4-BPW30 3-1/2 x 14 1-3/4 Z4-BPW17-6 Z4-BPW27-6 Z4-BPW36-6 Z4-BPW43-6 5 x 5-7/8 5x9 5 x 12 5 x 14 5/8 1 1-1/2 1-3/4 Z4-BPW46-6 5 x 15 1-7/8 1-9/16˝ 6˝ Allowable Bearing Capacity (lbs.) 3, 4 Color DF-L (625 psi.) SP (565 psi.) HF (405 psi.) SPF (425psi.) Brown Red Yellow Green Blue Black White Orange Lt. Grey 4,7805,6 5,660 7,690 8,960 10,750 14,800 19,600 24,500 29,450 4,3205 5,110 6,950 8,100 9,700 13,400 17,750 22,150 26,600 3,100 3,670 4,980 5,800 6,960 9,590 12,700 15,900 19,050 3,250 3,845 5,230 6,090 7,300 10,060 13,350 16,650 20,000 Lt. Blue Tan Grey Purple 17,150 26,950 36,300 42,550 15,500 24,350 32,800 38,450 11,100 17,450 23,500 27,550 11,650 18,300 24,700 28,950 Pink 45,700 41,300 29,600 31,050 1. Bearing Plate Washer are fabricated from ASTM A36 steel 2. Thicknesses are such that allowable bearing capacity is not limited by plate bending. 3. Bearing Plate Washer capacities are governed by compression of wood with no limitation to plate bending. 4. Allowable Bearing Capacity = (Aplate – Ahole)x (f’c⊥ of Wood Species); where f’c⊥ = allowable compression perpendicular to grain 5. Allowable Bearing Capacity = 4,160 lbs. when used with CNX-3 6. Allowable Bearing Capacity = 4,445 lbs. when used with CNX-4 3 Tie-Down System Z-Rod (ZR) Z-Rods in the system transfer cumulative tension loads into the foundation due to overturning force and wind uplift. Z-Rods are threaded at each end for making connections to the CNX Cinch Nut and to Coupler Nuts but unthreaded in the body. Because the steel for threading has not been removed from the body of the rod, elongation from tension loading is less than it would be for an all-thread product. Z-Rods conforming to ASTM A36 are plain finish and those conforming to ASTM A193 Grade B7 are zinc plated. 144" 108" UNTHREADED LENGTH TYPICAL Z4-ZR 5 x 10 STD 90" 120" 14" 26" 32" THREADED FOR CINCH NUT (CNX) AND COUPLER CONNECTIONS 6' Z ROD COUPLER CONNECTION TO ROD BELOW 4" 4" 4" 72" 54" THREADED FOR 10' Z ROD Standard Grade ASTM-A36 Z-Rod Length in feet Z-Rod Diameter (1/8” increments) Z-Rod 12' Z ROD Z-ROD (ZR) Model Number1,2 4 Z4-ZR3STD Z4-ZR3HS Z4-ZR4STD Z4-ZR4HS Z4-ZR5STD Z4-ZR5HS Z4-ZR6STD Z4-ZR6HS Z4-ZR7STD Z4-ZR7HS Z4-ZR8STD Z4-ZR8HS Z4-ZR9STD Z4-ZR9HS Z4-ZR10STD Z4-ZR10HS Z4-ZR11STD Z4-ZR11HS Z4-ZR12STD Z4-ZR12HS Diameter (in.) Cross-Sectional Area (in.2) At 3 Au 4 3/8 0.078 0.110 1/2 0.142 0.196 5/8 0.226 0.307 3/4 0.334 0.442 7/8 0.462 0.601 1 0.606 0.785 1-1/8 0.763 0.994 1-1/4 0.969 1.227 1-3/8 1.155 1.485 1-1/2 1.405 1.767 Allowable Tensile Capacity (lbs.) 5 2,400 5,175 4,270 9,205 6,675 14,380 9,610 20,710 13,080 28,1285 17,080 36,815 21,620 46,595 26,690 57,525 32,295 69,605 38,435 82,835 1. STD rod is plain finish and conforms to ASTM-A36. 2. HS rod is zinc plated and con forms to ASTM-A193 Grade B7. 3. At represents the effective cross-sectional area of threaded length of ZR. 4. Au represents the nominal cross-sectional area of unthreaded length of ZR. 5. Z-Rod capacities are based on AISC no increase permitted. HIGH STRENGTH COUPLER CINCH NUT (CNX) INSTALLATION Tie-Down System WITNESS HOLE HIGH STRENG REDUCER C1 BEARIN Coupler (CNW) NOTCHES INDICATE HIGH STRENGTH The Z4 Tie-Down System begins by connecting the first level Z-Rod to the hold down anchor in the foundation with a Coupler. At upper levels Couplers are used to connect Z-Rods end to end toWITNESS create a continuous load path. Reducers are Couplers that connect two Rods that are different STANDARD STANDARD HOLE diameters. COUPLER REDUCER HIGH STRENGTH WITNESS HOLEHIGH STRENGTH COUPLER REDUCER WITNESS HOLE Notches indicate High Strength THREAD ROD IN HALF WAY FROM EACH SIDE, VISIBLE STANDARD THROUGH SITE HOLE REDUCER STANDARD COUPLER FULLY SEAT LAR ROD FIRST, FULLY S DIA. ROD SEC SO REDUCER CANN NOTE: ROD THREADS SHALL FULLY ENGAGE COUPLER WITNESS HOLE THREAD ROD IN HALF WAY Coupler ReducerFROM EACH SIDE, VISIBLE THROUGH SITE HOLE Z4-CNW 6/5 STD COUPLER NUT (CNW) FULLY SEAT LARGE DIA. ROD FIRST, FULLY SEAT SMALL DIA. ROD SECOND SO REDUCER CANNOT TURN NOTE: ROD THREADS SHALL FULLY ENGAGE COUPLER Rod Grade COUPLER NUT (CNW) Smaller Connecting Rod Diameter (1/8” increments) Larger Connecting Rod Diameter (1/8” increments) Coupler Nut with Witness Hole C3 Z-ROD Advantages • All Couplers and Reducers have a higher capacity than those of the Z-Rods being connected. When joining Z-Rods with different tensile strengths the Coupler capacity is higher than the rod with the higher strength. • Reducers are couplers used to connect Z-Rods with different diameters to combine the most effective and most economical rod needed at each level. • Witness holes are provided to assure easy inspection. Finish Zinc Plated or Plain Finish available Installation Thread Coupler onto the two Z-Rods ends 5 Tie-Down System Anchor Tie (AT) The Anchor Tie is a structural component designed for connecting Z4 Tie-Down Runs to steel members. Anchor Ties are fabricated from ASTM Grade A36 steel plate and include a pre-welded nut, making the Tie-Down connection quick and easy. ATs are available in 9 and 12 inch heights. Other heights available upon request. The 9 inch version with 1/4 inch plate steel legs is available for connecting 5/8” through 1-1/2” diameter threaded rod and the 12 inch version with twice the steel thickness at the legs is used for connecting up to 2” diameter rod. Common applications include connecting to steel plates at concrete decks and steel beams where Tie-Down runs terminate. When installing at concrete decks, steel plates are designed by the Engineer of Record to resist the uplift loads. After concrete is poured, the AT is welded to the plate and a threaded rod is connected to the Anchor Ties’ pre-welded nut enabling the Tie-Down Run from above to attach. Steel beam installations are designed by the EOR. The Anchor Tie is welded to the beam prior to floor framing then attachment of the threaded rod and Tie-Down Run completes the installation. Z4-AT 32-3 Rod Diameter (1/8" increments) Allowable ASD Uplift Anchor Tie ANCHOR TIE (AT) 1, 2, 3 Model Number 6 Width Depth 3/8 Z4-AT32-4 1/2 Z4-AT32-5 5/8 Z4-AT32-6 3/4 Z4-AT32-8 9 3 1/2 3 7/8 1 Z4-AT32-9 1 1/8 Z4-AT32-10 1 1/4 Z4-AT32-11 1 3/8 Z4-AT32-12 1 1/2 Z4-AT65-5 5/8 Z4-AT65-6 3/4 Z4-AT65-7 7/8 Z4-AT65-8 1 Z4-AT65-9 Z4-AT65 Height Connecting Rod Diameter (in.) Z4-AT32-3 Z4-AT32-7 Z4-AT32 Dimensions (in.) 11 3/4 4 1/4 3 1/2 1 1/8 Z4-AT65-10 1 1/4 Z4-AT65-11 1 3/8 Z4-AT65-12 1 1/2 Z4-AT65-16 2 Allowable Uplift (lbs.) 4 ASD LRFD 32,400 48,600 64,800 97,200 1. Weld size to steel member below is 1/4” for AT32 and 5/16” for AT65. Weld length is 3 inches for each leg, one side for AT32 and two sides for AT65. 2. Design of the steel member below the Anchor Tie is the responsibility of the EOR. 3. All plate material is ASTM A36. 4. Allowable uplift loads are per AISC no increase permitted. Tie-Down System Installation ROOF RAFTERS Z4 Tie-Down System for Lateral Loads 1. USP WS-SCREWS 2. CINCH NUT 3. BEARING PLATE WASHER 4. Z-ROD Z4 Tie-Down Systems utilize CNX-Series Cinch Nuts to compensate for wood shrinkage and building settlement that cause connections to loosen over time. The Cinch Nut uses a self-ratcheting action that permits the cinch nut to move (the rod doesn’t move) or “travel” perpetually in one direction only down the rod. Available for installation with threaded rods that are 3/8 inch through 1-1/2 inch diameter in 1/8 inch increments, the CNX Cinch Nut has been code evaluated and published in ESR-2190. •Place the specified Bearing Plate Washer onto the bottom plate of a wood framed wall. •With the “wings” oriented downward, place Cinch Nut over the Z-Rod extending from below and push down until it seats firmly on the Bearing Plate Washer. •Install 1/4 inch diameter USP WS-Series screws through the wings, penetrating 1 -1/2 inches (minimum) into the wood bottom plate. •Model numbers BPW5 and BPW6 fit in-between the screws fastening the wings. •Model numbers BPW7 (3-1/4 x 4-3/8) and larger are provided with two screw holes. Align the wing and the Bearing Plate Washer screw holes to allow installation of 1/4 inch diameter WS-Series screws. ROOF RAFTERS To resist tension loads due to overturning moments in multi-story buildings the CNX Cinch Nut is installed over a Bearing Plate Washer at each level in a fast and easy application. At the upper-most level a Cinch Nut is installed over a Bearing Plate Washer above the top plates. At walls below that bear on wood floor systems, the Cinch Nut and Bearing Plate Washer are installed over the bottom plate. Tension loads are gathered at each level and transferred into the foundation through a continuous system of Cinch Nuts, Bearing Plate Washers, Z-Rods/ATRs and Couplers all available from MiTek® Builder Products. Z4 Tie-Down System for Wind Uplift For resisting roof uplift loads resulting from wind the Z4 Cinch Nut is installed over a Bearing Plate Washer above the top plates with roof framing above to create a tie-down system. Uplift forces are transferred into a continuous system of Z-Rods / ATRs and Couplers that form a load path to the foundation. 7 BPW5, BPW6 Installation BPW7 and larger Installation Design Example Introduction The Z4 Tie-Down System is comprised of multiple threaded rods joined with coupling nuts to create a continuous, multi-story Tie-Down Run that is connected to the structure at each floor with a Z4-CNX Cinch Nut installed over a Z4-Bearing Plate Washer. Overturning of the building shear walls create an uplift force on the floor below that is resisted by the Z4 Tie –Down System. In multi-story structures the uplift tension forces are transferred into the rods at each floor and/or roof level and are cumulative from the top to the bottom of the Run. In this catalog we provide three Design Examples that utilize Z4 components to resist tension loads. • Design by referencing the Quick Reference Table (Assumes 10 foot rod lengths and 0.0200 inch deflection limit) • Design by using the catalog tables for each individual component including the CNX, BPW, Z-R and CNW • Design by using USP Specifier Design Software. Design Example By Quick Reference Table GIVEN Wood Type: Douglas Fir-Larch Code: 2012 IBC Maximum Rod Elongation Per Floor = 0.200" Maximum Total Deformation Per Floor = 0.200" Story Height: 9' 0" Floor System Depth = 1' 0" Use: Z-Rod Length = 2nd Floor Story Height + Floor System Depth = 10' Z-Rod Top Floor ASD Design Uplift Load = 6.0 Kips ASD Design Uplift Load of floor being considered = 9.0 Kips Cumulative ASD Design Uplift Load = 6.0 Kips + 9.0 Kips = 15.0 Kips 6,000 lbs. 1' 0" 9,000 lbs. LOOKUP BY ALLOWABLE LOADS A. Refer to Quick Reference Table 10.2: Z-Rod Length = 10’ Maximum Total Deformation Per Floor = 0.200” OK! OK! B. Refer to Cumulative Load column: Find value > Cumulative ASD Design Uplift Load Select 16,050 lbs. > 15,000 lbs. OK! C. Refer to the Individual Floor Load – DF-L column: Find value > ASD Design Uplift Load Select 10,750 lbs. > 9,000 lbs. OK! 9' 0" Note: This example uses 0.200” deflection limit and a 10 ft. rod length. Design criteria may vary by building jurisdiction and job specific requirements. D. Follow Row Across to Determine Components: • ZR-8 STD • CNX-8 • BPW11 (3-1/4 x 5-7/8) A D QUICK REFERENCE TABLE 10.2: FOR 10-FT Z-ROD, TOTAL LEVEL DISPLACEMENT ≤ 0.200” 1 Model Number Components 5 Elongation Total Level Displacement (in) Cinch Nut of Z-Rod (CNX) 6 (in) 4 DF-L HF SPF SP Z-Rod (ZR) Bearing Plate Washer (BPW) Dimensions CNX-3 ZR-3 STD 3x3 CNX-4 ZR-4 STD 2,400 2,400 3,100 3,250 4,270 - 3,670 C 2,400 4,270 3,850 - Z-8STD-3-1/4 x 4-3/8 7,690 4,980 5,230 6,950 0.192 0.190 0.190 0.191 Z-8STD-3-1/4 x 5 8,960 5,800 6,090 8,100 0.193 0.191 0.191 0.192 3-1/4 x 5 10,750 6,960 7,300 9,700 0.195 0.191 0.192 0.194 3-1/4 x 5-7/8 0.198 0.194 0.194 0.197 Z-4STD-3 x 3 Z-4STD-3-1/4 x 3-3/8 Z-8STD-3-1/4 x 5-7/8 Z-8STD-3-1/4 x 7-7/8 4” 4” 4" B Vertical Displacement (in.) 2,400 Z-3STD-3 x 3 8 Allowable Uplift (lbs.) Minimum Wall Individual Floor Load (lbs) 3 Framing Nominal Cumulative2 Depth Load (lbs) DF-L HF SPF SP 2,400 4,270 16,050 14,800 9,590 10,050 13,400 0.099 0.099 0.091 0.157 0.161 0.159 0.157 0.190 0.194 0.194 0.196 - 0.195 0.196 - 3x3 3-1/4 x 3-3/8 3-1/4 x 4-3/8 CNX-8 ZR-8 STD 3-1/4 x 7-7/8 Design Example Quick Reference Table QUICK REFERENCE TABLE 10.2: FOR 10-FT Z-ROD, TOTAL LEVEL DISPLACEMENT ≤ 0.200” 1 Model Number Minimum Wall Framing CumulaNominal tive Load Depth (lbs) 2 Allowable Uplift (lbs.) Vertical Displacement (in.) Individual Floor Load (lbs) 3 Components 5 Elongation Total Level Displacement (in) Cinch Nut of Z-Rod (CNX) 6 (in) 4 DF-L HF SPF SP Z-Rod (ZR) Bearing Plate Washer (BPW) Dimensions CNX-3 ZR-3 STD 3x3 CNX-4 ZR-4 STD 3-1/4 x 3-3/8 DF-L HF SPF SP 2,400 2,400 2,400 2,400 4,270 3,100 3,250 4,270 - 3,670 3,850 - Z-4STD-3-1/4 x 4-3/8 - 4,270 4,270 - Z-5STD-3 x 3 4,780 3,100 3,250 4,320 0.196 0.194 0.194 0.195 3x3 Z-5STD-3-1/4 x 3-3/8 5,660 3,670 3,850 5,110 0.197 0.194 0.195 0.196 3-1/4 x 3-3/8 6,680 4,980 5,230 6,680 0.190 0.196 0.196 0.196 Z-3STD-3 x 3 4” 2,400 4” 4,270 Z-4STD-3 x 3 Z-4STD-3-1/4 x 3-3/8 Z-5STD-3-1/4 x 4-3/8 4” 6,680 0.099 0.099 0.098 0.157 0.161 0.159 0.157 0.190 0.194 0.194 0.196 - 0.195 0.196 - - 0.188 0.185 - 3x3 3-1/4 x 4-3/8 CNX-5 ZR-5 STD 3-1/4 x 4-3/8 Z-5STD-3-1/4 x 5 - 5,800 6,090 - - 0.197 0.198 - 3-1/4 x 5 Z-5STD-3-1/4 x 5-7/8 - 6,680 6,680 - - 0.196 0.193 - 3-1/4 x 5-7/8 Z-6STD-3 x 3 4,780 3,100 3,250 4,320 0.194 0.191 0.192 0.193 3x3 Z-6STD-3-1/4 x 3-3/8 5,660 3,670 3,850 5,110 0.195 0.192 0.192 0.194 3-1/4 x 3-3/8 Z-6STD-3-1/4 x 4-3/8 7,690 4,980 5,230 6,950 0.197 0.194 0.194 0.196 8,840 5,800 6,090 8,100 0.198 0.195 0.195 0.198 Z-6STD-3-1/4 x 5-7/8 - 6,960 7,300 8,840 - 0.196 0.197 0.194 3-1/4 x 5-7/8 Z-6STD-3-1/4 x 7-7/8 - 8,840 8,840 - - 0.194 0.192 - 3-1/4 x 7-7/8 - 8,840 8,840 - - 0.187 0.185 - 5 x 5-7/8 Z-6STD-3-1/4 x 5 Z-6STD-5 x 5-7/8 4” 8,840 6” 0.089 3-1/4 x 4-3/8 CNX-6 ZR-6 STD 3-1/4 x 5 Z-7STD-3 x 3 4,780 3,100 3,250 4,320 0.191 0.190 0.190 0.191 3x3 Z-7STD-3-1/4 x 3-3/8 5,660 3,670 3,850 5,110 0.192 0.190 0.191 0.192 3-1/4 x 3-3/8 Z-7STD-3-1/4 x 4-3/8 7,690 4,980 5,230 6,950 0.194 0.192 0.192 0.193 3-1/4 x 4-3/8 8,960 5,800 6,090 8,100 0.195 0.192 0.192 0.194 3-1/4 x 5 10,750 6,960 7,300 9,700 0.196 0.193 0.193 0.195 3-1/4 x 5-7/8 0.191 0.195 0.196 0.197 Z-7STD-3-1/4 x 5 Z-7STD-3-1/4 x 5-7/8 4” 13,100 Z-7STD-3-1/4 x 7-7/8 13,100 9,590 10,050 13,100 0.097 CNX-7 ZR-7 STD 3-1/4 x 7-7/8 Z-7STD-3-1/4 x 10-1/4 - 12,700 13,100 - - 0.198 0.197 - 3-1/4 x 10-1/4 Z-7STD-3-1/2 x 11-3/4 - 13,100 - - 0.188 - - 3-1/2 x 11-3/4 Z-7STD-5 x 5-7/8 - 11,100 11,650 13,100 - 0.197 0.197 0.189 5 x 5-7/8 - 13,100 13,100 5x9 Z-7STD-5 x 9 6” - - - 0.183 0.182 - Z-8STD-3 x 3 4,780 3,100 3,250 4,320 0.190 0.188 0.188 0.189 3x3 Z-8STD-3-1/4 x 3-3/8 5,660 3,670 3,850 5,110 0.190 0.189 0.189 0.190 3-1/4 x 3-3/8 Z-8STD-3-1/4 x 4-3/8 7,690 4,980 5,230 6,950 0.192 0.190 0.190 0.191 3-1/4 x 4-3/8 Z-8STD-3-1/4 x 5 8,960 5,800 6,090 8,100 0.193 0.191 0.191 0.192 3-1/4 x 5 10,750 6,960 7,300 9,700 0.195 0.191 0.192 0.194 3-1/4 x 5-7/8 Z-8STD-3-1/4 x 5-7/8 4” Z-8STD-3-1/4 x 7-7/8 16,050 Z-8STD-3-1/4 x 10-1/4 Z-8STD-3-1/2 x 14 Z-8STD-5 x 9 0.091 16,050 12,700 13,350 16,050 Z-8STD-3-1/2 x 11-3/4 Z-8STD-5 x 5-7/8 14,800 9,590 10,050 13,400 - 15,900 16,050 - - 16,050 - - 16,050 11,100 11,650 15,500 6” - 16,050 16,050 16,050 0.198 0.194 0.194 0.197 0.188 0.196 0.197 0.193 3-1/4 x 10-1/4 - 0.199 0.197 - 3-1/2 x 11-3/4 CNX-8 ZR-8 STD 3-1/4 x 7-7/8 - 0.190 - - 3-1/2 x 14 0.195 0.195 0.195 0.199 5 x 5-7/8 - 0.194 0.192 0.184 5x9 Z-10STD-3 x 3 4,780 3,100 3,250 4,320 0.191 0.190 0.190 0.191 3x3 Z-10STD-3-1/4 x 3-3/8 5,660 3,670 3,850 5,110 0.191 0.190 0.190 0.191 3-1/4 x 3-3/8 Z-10STD-3-1/4 x 4-3/8 7,690 4,980 5,230 6,950 0.192 0.191 0.191 0.192 3-1/4 x 4-3/8 8,960 5,800 6,090 8,100 10,750 6,960 7,300 9,700 Z-10STD-3-1/4 x 5 Z-10STD-3-1/4 x 5-7/8 Z-10STD-3-1/4 x 7-7/8 4” 20,300 14,800 9,590 10,050 13,400 0.073 0.193 0.191 0.192 0.193 0.194 0.192 0.192 0.193 0.196 0.193 0.194 0.195 3-1/4 x 5 CNX-10 ZR-10 STD 3-1/4 x 5-7/8 3-1/4 x 7-7/8 Z-10STD-3-1/4 x 10-1/4 19,600 12,700 13,350 17,750 0.199 0.195 0.195 0.198 3-1/4 x 10-1/4 Z-10STD-3-1/2 x 11-3/4 20,300 15,900 16,650 20,300 0.189 0.197 0.197 0.194 3-1/2 x 11-3/4 - 0.198 0.199 - 3-1/2 x 14 Z-10STD-3-1/2 x 14 - 19,050 20,000 - 9 Design Example Quick Reference Table QUICK REFERENCE TABLE 10.2: FOR 10-FT Z-ROD, TOTAL LEVEL DISPLACEMENT ≤ 0.200” 1 Model Number Minimum Wall Framing CumulaNominal tive Load Depth (lbs) 2 Z-10STD-5 x 5-7/8 Z-10STD-5 x 9 Allowable Uplift (lbs.) Individual Floor Load (lbs) 3 DF-L HF 6” 21,300 0.198 0.189 0.188 - 5 x 12 3,250 4,320 0.191 0.190 0.190 0.191 3x3 3,670 3,850 5,110 0.191 0.190 0.190 0.191 3-1/4 x 3-3/8 4,980 5,230 6,950 0.192 0.191 0.191 0.192 3-1/4 x 4-3/8 5,800 6,090 8,100 0.193 0.191 0.192 0.193 3-1/4 x 5 10,750 6,960 7,300 9,700 0.194 0.192 0.192 0.194 3-1/4 x 5-7/8 14,800 9,590 10,050 13,400 0.196 0.194 0.194 0.196 0.199 0.195 0.196 0.198 0.192 0.197 0.197 0.198 3-1/2 x 11-3/4 - 0.199 0.199 - 3-1/2 x 14 17,150 11,100 11,650 15,500 0.198 0.194 0.195 0.197 5 x 5-7/8 21,400 17,450 18,300 21,400 5,660 7,690 Z-9STD-3-1/4 x 5 8,960 Z-9STD-3-1/2 x 11-3/4 20,300 20,300 19,600 12,700 13,350 17,750 - Z-9STD-5 x 5-7/8 6” 19,050 20,000 0.198 0.193 5x9 0.195 0.192 - 5 x 12 3,850 5,110 0.190 0.189 0.189 0.190 3-1/4 x 3-3/8 4,980 5,230 6,950 0.191 0.190 0.190 0.191 3-1/4 x 4-3/8 5,800 6,090 8,100 0.192 0.190 0.190 0.191 3-1/4 x 5 10,750 6,960 7,300 9,700 0.193 0.191 0.191 0.192 3-1/4 x 5-7/8 3,670 Z-11STD-3-1/4 x 4-3/8 7,690 Z-11STD-3-1/4 x 5 8,960 21,400 21,400 14,800 9,590 10,050 13,400 22,300 Z-11STD-3-1/2 x 11-3/4 19,600 12,700 13,350 17,750 0.067 22,300 15,900 16,650 22,150 Z-11STD-3-1/2 x 14 - Z-11STD-5 x 5-7/8 6” 3-1/4 x 7-7/8 3-1/4 x 10-1/4 0.198 5,660 Z-11STD-3-1/4 x 10-1/4 ZR-9 STD 5x9 - Z-11STD-3-1/4 x 3-3/8 4” - CNX-9 ZR-10 STD 0.188 - Z-11STD-5 x 9 0.096 CNX-10 - Z-12STD-5 x 12 Z-11STD-3-1/4 x 7-7/8 0.073 21,400 15,900 16,650 21,400 Z-9STD-3-1/2 x 14 5 x 5-7/8 0.191 Z-9STD-3-1/4 x 4-3/8 21,400 0.197 0.198 Z-9STD-3-1/4 x 3-3/8 Z-9STD-3-1/4 x 10-1/4 0.195 - 3,100 4” 0.194 Bearing Plate Washer (BPW) Dimensions 0.184 4,780 Z-9STD-3-1/4 x 7-7/8 0.197 Z-Rod (ZR) - Z-9STD-3 x 3 Z-11STD-3-1/4 x 5-7/8 SP 20,300 17,450 18,300 20,300 - Z-9STD-5 x 9 SPF Components 5 Elongation Total Level Displacement (in) Cinch Nut of Z-Rod (CNX) 6 (in) 4 DF-L HF SPF SP 17,150 11,100 11,650 15,500 Z-12STD-5 x 12 Z-9STD-3-1/4 x 5-7/8 Vertical Displacement (in.) 19,050 20,000 22,300 0.195 0.192 0.192 0.194 0.197 0.194 0.194 0.196 3-1/4 x 7-7/8 0.193 0.195 0.196 0.199 3-1/2 x 11-3/4 CNX-11 ZR-11 STD 3-1/4 x 10-1/4 - 0.197 0.197 0.189 3-1/2 x 14 17,150 11,100 11,650 15,500 0.196 0.193 0.193 0.195 5 x 5-7/8 22,300 17,450 18,300 22,300 0.188 0.196 0.197 0.193 5x9 Z-12STD-5 x 12 - - - 0.195 0.193 - 5 x 12 Z-12STD-3-1/4 x 3-3/8 5,660 3,670 3,850 5,110 0.189 0.188 0.188 0.189 3-1/4 x 3-3/8 Z-12STD-3-1/4 x 4-3/8 7,690 4,980 5,230 6,950 0.190 0.189 0.189 0.189 3-1/4 x 4-3/8 8,960 5,800 6,090 8,100 0.190 0.189 0.189 0.190 3-1/4 x 5 10,750 6,960 7,300 9,700 0.191 0.189 0.190 0.191 3-1/4 x 5-7/8 14,800 9,590 10,050 13,400 0.193 0.191 0.191 0.192 3-1/4 x 7-7/8 Z-12STD-3-1/4 x 5 Z-12STD-3-1/4 x 5-7/8 Z-12STD-3-1/4 x 7-7/8 4” Z-12STD-3-1/4 x 10-1/4 22,300 22,300 19,600 12,700 13,350 17,750 30,000 Z-12STD-3-1/2 x 11-3/4 Z-12STD-3-1/2 x 14 24,500 15,900 16,650 22,150 29,450 19,050 20,000 26,600 0.075 0.195 0.192 0.192 0.194 0.197 0.193 0.194 0.196 3-1/4 x 10-1/4 0.199 0.195 0.195 0.198 3-1/2 x 14 5 x 5-7/8 CNX-12 ZR-12 STD 3-1/2 x 11-3/4 Z-12STD-5 x 5-7/8 17,150 11,100 11,650 15,500 0.194 0.191 0.192 0.193 Z-12STD-5 x 9 26,950 17,450 18,300 24,350 0.198 0.194 0.194 0.197 5x9 30,000 23,500 24,700 30,000 0.189 0.197 0.197 0.194 5 x 12 Z-12STD-5 x 12 6” Z-12STD-5 x 14 - 27,550 28,950 - - 0.198 0.199 - 5 x 14 Z-12STD-5 x 15 - 29,600 30,000 - - 0.199 0.197 - 5 x 15 Notes: 10 1. The values in this table are Allowable Stress Design (ASD) excluding a 1.33 stress increase and pertain to a maximum 0.20 in. total vertical displacement per floor. Values shown pertain to a 10-foot Z-Rod length (L) and wood design values in accordance with 2012 NDS per species shown. 2. The allowable cumulative load is the Z-Rod (ZR) capacity to resist tension forces equal to the sum of individual floor loads from each level above the Cinch Nut (CNX) connection being considered. 3. The allowable individual floor load is the Cinch Nut (CNX) and Bearing Plate Washer (BPW) capacity to transfer uplift forces from the single level being considered into the Z-Rod (ZR). 4. Elongation of the Z-Rod is determined by calculating (PLT/ATE) + (PLU/AUE) ; where P = cumulative tension force, LT = length of rod with threads (.25L), LU = length of rod without threads (.75L), AT = effective cross sectional area of rod length with threads, AU = net cross sectional area of rod length without threads, and E = Modulus of Elasticity (29x106) . 5. Total vertical displacement is the sum of wood deformation due to compression of the Bearing Plate Washer (BPW), total movement of the Cinch Nut (CNX), and total Z-Rod (ZR) elongation per floor. 6. Cinch Nut model numbers CNX-5 through CNX-12 are evaluated and approved per ICC-ES (ESR-2190); CNX-3 & CNX-4 are ESR pending. Design Example By Component Capacities GIVEN Wood Type: Douglas Fir-Larch Code: 2012 IBC Maximum Rod Elongation Per Floor = 0.200" Maximum Total Deformation Per Floor = 0.200" Story Height: 9' 0" Floor System Depth = 1' 0" Use: Z-Rod Length = 2nd Floor Story Height + Floor System Depth = 10' Z-Rod Top Floor ASD Design Uplift Load = 6.0 Kips ASD Design Uplift Load of floor being considered = 9.0 Kips Cumulative ASD Design Uplift Load = 6.0 Kips + 9.0 Kips = 15.0 Kips 6,000 lbs. 1' 0" STEP 1. LOOKUP COMPONENT CAPACITIES A. Bearing Plate Washer (BPW) Capacity > ASD Design Uplift Load: BPW 11 (3-1/4 x 5-7/8) Capacity = 10,750 lbs. > 9,000 lbs OK! B. Standard-Grade Z-Rod (ZR) Capacity > Cumulative ASD Design Uplift Load: ZR-8 STD Capacity = 17,080 lbs. > 15,000 lbs. OK! C. Cinch Nut (CNX) Hole Diameter = Z-Rod (ZR) Diameter: CNX-8 (1" hole diameter) = ZR-8 STD (1" diameter) D. Check: Cinch Nut (CNX) Capacity > ASD Design Uplift Load: CNX-8 capacity = 29,285 lbs. > 9,000 lbs. OK! STEP 2. CALCULATE TOTAL FLOOR DEFORMATION 9,000 lbs. 9' 0" Note: This example uses 0.200” deflection limit and a 10 ft. rod length. Design criteria may vary by building jurisdiction and job specific requirements. ∆T = ∑ (∆L+ ∆M+ ∆W ) ∆L = Z-Rod Elongation ∆M = Cinch Nut Movement ∆W = Bearing Plate Washer Deformation into Wood STEP 3 Check total floor deformation ≤ code limit The ICC-Evaluation Service Acceptance Criteria for Shrinkage Compensating Devices (AC316) requires the Building Design Professional to consider a 0.20-inch (5 mm) vertical displacement limit for shear wall drift limit calculations. The 0.20-inch vertical displacement limit can be exceeded when: • All sources of vertical displacement are considered • The shear wall story drift limit is not exceeded • The deformation compatibility requirements of IBC Section 1604.4 are being met. 11 Design Example Using USP Specifier Design Software GIVEN Wood Type: Douglas Fir-Larch Code: 2012 IBC Maximum Rod Elongation Per Floor = 0.200" Maximum Total Deformation Per Floor = 0.200" Story Height: 9' 0" Floor System Depth = 1' 0" Use: Z-Rod Length = 2nd Floor Story Height + Floor System Depth = 10' Z-Rod Top Floor ASD Design Uplift Load = 6.0 Kips ASD Design Uplift Load of floor being considered = 9.0 Kips Cumulative ASD Design Uplift Load = 6.0 Kips + 9.0 Kips = 15.0 Kips Open USP Specifier program Click “Z4 Quick Connect Design” in the toolbar Option with built-up 2x4 and 2x6 member posts are also available 6,000 lbs. 1' 0" 9,000 lbs. 9' 0" DESIGN PARAMETERS Step 1: Define Design Conditions • Select the “Number of Levels” (up to six) in the Run. • If more than one of the same run occurs, increase the total “Quantity” accordingly. • “Label Prefix” is a user definable field that allows for custom labeling of Runs. • Check the “Fire-Treated” box if lumber is required to be fire-retardant. Note: This example uses 0.200” deflection limit and a 10 ft. rod length. Design criteria may vary by building jurisdiction and job specific requirements. Step 2: Define Start Conditions • Select the “Start Level” in which the Run begins. • Select the anchoring condition (concrete, wood beam, or steel beam). • Note: When wood or steel beam is selected for anchoring a field becomes available for labeling. Step 3: Define Cap Conditions • Select the “Cap Condition” for the Run termination at the uppermost level. • Note: When a “bridge” cap is selected a field becomes available for labeling. Step 4: Define Floor Heights • Input the overall floor height at each level by clicking on the dimension shown to the left of the Run illustration. • Input the floor system depth at each level by clicking on the dimension shown to the left of the Run illustration. DESIGN LOADS Step 1: At the Table provided input “Level Tension” at each floor of the Run. • Note: Table values will automatically be generated based on inputs at each floor. • Note: Components meeting a Total Level Deflection limit of 0.200” per floor will automatically be inserted and labeled in the Run. Step 2: Input any “Additional Compression” at each floor located in the table to the right of each level in the Run. COMPRESSION MEMBERS Step 1: Confirm that all compression members shown to the left of the Run are displayed in black font. • Note: When red font occurs, use pull down menu to select appropriate compression members to satisfy “Accumulated Compression” per floor. ANCHOR ROD Step 1: Anchor rod diameter, grade, length, and stub-up height are to be determined by the Engineer of Record. 12 DESIGN REVIEW Step 1: Confirm green checkmarks appear in the status column of each row in the tables. USP Specifier™ Design Software CNX-5 BPW-7 108” Wall Plates Option 1 2x4 DF No.2 Option 2 2x6 DF No.2 Ea. Side Post 2x4 DF No. 2 (1) 2x6 DF No. 2 (1) Ei. Side Post None 2x4 DF No. 2 (1) 108” Component Level Summary ZR5x9 STD LEVEL 5 CNW8/5 STD CNX-8 BPW-11 120” 12” 108” Option 1 2x4 DF No.2 Option 2 2x6 DF No.2 Ea. Side Post 4x4 DF No.1 (1) 3x6 DF No. 2 (1) Ei. Side Post None 3x4 DF No. 2 (1) ZR8x10 STD CNW 8 STD LEVEL 4 120” Wall Plates 12” CNX-8 BPW-5 108” Wall Plates 2x4 DF No.2 Option 2 2x6 DF No.2 3x6 DF No. 2 (1) ZR8x10 STD 2x6 DF No. 2 (1) CNW9/8 STD LEVEL 3 None 120” Option 1 Ea. Side Post 4x6 DF No.1 (1) Ei. Side Post 12” CNX-9 BPW-5 6000 7,690 6000 6,675 Additional Compression (lbs) 500 8,040 Accumulated Compression (lbs) 6500 8,040 Total Level Deflection (in) 0.167 0.200 Total Rod Elongation (in) 0.088 0.200 Design Control Level Tension (lbs) 9000 10,750 Accumulated Tension (lbs) 15000 17,080 Additional Compression (lbs) 1000 17,880 Accumulated Compression (lbs) 16500 17,880 Total Level Deflection (in) 0.175 0.200 Total Rod Elongation (in) 0.085 0.200 Design Control Level Tension (lbs) 1000 4780 Accumulated Tension (lbs) 16000 17,080 Additional Compression (lbs) 500 21,020 Accumulated Compression (lbs) 18000 21,020 Total Level Deflection (in) 0.152 0.200 Total Rod Elongation (in) 0.091 0.200 Component Option 1 2x4 DF No.2 Option 2 2x6 DF No.2 Ea. Side Post 4x6 DF No. 1 (1) 6x4 DF No. 1 (1) Ei. Side Post 2x6 DF No. 2 (1) ZR9x10 STD CNW12/9 STD LEVEL 2 3x4 DF No. 2 (1) 120” Level Summary Wall Plates 108” Level Tension (lbs) Accumulated Tension (lbs) Level Summary Component 120” Control Level Summary Component 120” Design Control 4780 4,780 Accumulated Tension (lbs) 20780 21,620 Additional Compression (lbs) 2220 25,490 Accumulated Compression (lbs) 25000 25,490 Total Level Deflection (in) 0.188 0.200 Total Rod Elongation (in) 0.093 0.200 Status Status Status 12” CNX-12 BPW-6 Design Level Tension (lbs) Status Option 2 2x6 DF No.2 Ea. Side Post 4x8 DF No. 1 (1) 6x4 DF No.1 (1) Ei. Side Post 3x6 DF No. 2 (1) 3x4 DF No. 2 (1) ZR12 x 10 STD CNW16/12 STD A36 2 x 24 9” 108” Option 1 2x4 DF No.2 LEVEL 1 120” Component Wall Plates 120” Level Summary Design Control Level Tension (lbs) 5655 5,660 Accumulated Tension (lbs) 26435 38,435 Additional Compression (lbs) 1345 32,100 Accumulated Compression (lbs) 32000 32,100 Total Level Deflection (in) 0.181 0.200 Total Rod Elongation (in) 0.067 0.200 Status EXAMPLE (QTY: 1) USP Specifier Software Free project management and cost control software simplifies access to information on over 3000 structural connectors through an intuitive and graphical desktop interface. Available at: www.uspconnectors.com/resources/software Options with built-up 2x4 and 2x6 member posts are also available 13 Wood Member Compression Capacities TABLE 2.1- DF: COMPRESSION CAPACITIES FOR DOUGLAS FIR-LARCH 1, 2 Nominal Wall Depth, b3 (in) 4" 6" 8" Pc⊥ Maximum Nominal Lumber Lumber Grade Compression Capacity Dimensions Perpendicular to Grain (lbs.) 4, 5 2x4 2x4 3x4 3x4 4x4 4x6 4x8 4x10 4x12 2x6 2x6 3x6 3x6 6x4 6x6 6x8 6x10 6x12 2x8 3x8 4x8 6x8 8x8 8x10 8x12 No. 2 Stud No. 2 Stud No. 1 No. 1 No. 1 No. 1 No. 1 No. 2 Stud No. 2 Stud No. 1 No. 1 No. 1 No. 1 No. 1 No. 2 No. 2 No. 1 No. 1 No. 1 No. 1 No. 1 3,280 3,280 5,470 5,470 7,655 12,030 15,860 20,235 24,610 5,155 5,155 8,595 8,595 12,030 18,905 25,780 32,655 39,530 7,030 11,720 16,405 25,780 35,155 44,530 53,905 Pc - Maximum Design Compression Capacity Parallel to Grain (lbs.) 6, 7, 8, 9 Nominal Wall Height (ft.) 10 8 3,370 2,825 5,615 4,710 8,425 13,195 17,325 22,010 26,770 11,090 8,095 18,485 13,495 27,595 34,385 46,890 59,395 71,900 20,810 34,685 51,645 57,070 77,820 98,570 119,325 9 2,680 2,280 4,470 3,800 6,705 10,510 13,815 17,570 21,370 9,280 7,135 15,465 11,890 23,105 30,165 41,130 52,100 63,070 18,815 31,360 46,735 53,880 73,475 93,065 112,660 10 2,180 1,870 3,635 3,120 5,450 8,545 11,245 14,310 17,405 7,780 6,205 12,965 10,345 19,380 26,140 35,650 45,155 54,660 16,730 27,880 41,595 50,145 68,380 86,610 104,845 11 1,805 1,555 3,010 2,595 4,510 7,080 9,315 11,860 14,425 6,570 5,375 10,950 8,955 16,375 22,575 30,785 38,995 47,205 14,730 24,545 36,645 46,030 62,770 79,510 96,250 12 1,520 1,315 2,530 2,190 3,790 5,950 7,835 9,980 12,140 5,600 4,660 9,335 7,765 13,960 19,535 26,640 33,740 40,845 12,920 21,535 32,165 41,800 57,000 72,200 87,400 TABLE 2.1- HF: COMPRESSION CAPACITIES FOR HEM FIR 1, 2 Nominal Wall Depth, b3 (in) 4" 6" 8" 14 Pc⊥ Maximum Nominal Lumber Lumber Grade Compression Capacity Dimensions Perpendicular to Grain (lbs.) 4, 5 2x4 2x4 3x4 3x4 4x4 4x6 4x8 4x10 4x12 2x6 2x6 3x6 3x6 6x4 6x6 6x8 6x10 6x12 2x8 3x8 4x8 6x8 8x8 8x10 8x12 No. 2 Stud No. 2 Stud No. 1 No. 1 No. 1 No. 1 No. 1 No. 2 Stud No. 2 Stud No. 1 No. 1 No. 1 No. 1 No. 1 No. 2 No. 2 No. 1 No. 1 No. 1 No. 1 No. 1 2,125 2,125 3,545 3,545 4,960 7,795 10,275 13,110 15,945 3,340 3,340 5,570 5,570 7,795 12,250 16,705 21,160 25,615 4,555 7,595 10,630 16,705 22,780 28,855 34,930 Pc - Maximum Design Compression Capacity Parallel to Grain (lbs.) 6, 7, 8, 9 Nominal Wall Height (ft.) 10 8 2,745 2,450 4,570 4,085 7,430 11,635 15,275 19,410 23,605 9,385 7,285 15,640 12,140 24,455 28,450 38,795 49,140 59,485 18,660 31,100 46,115 47,960 65,400 82,840 100,280 9 2,180 1,970 3,630 3,285 5,915 9,270 12,185 15,495 18,850 7,735 6,340 12,890 10,565 20,450 24,785 33,795 42,810 51,820 16,475 27,460 41,630 45,070 61,455 77,845 94,235 10 1,770 1,615 2,950 2,690 4,810 7,540 9,920 12,625 15,355 6,425 5,465 10,710 9,105 17,140 21,370 29,145 36,915 44,685 14,355 23,925 36,970 41,715 56,885 72,050 87,220 11 1,465 1,345 2,440 2,240 3,980 6,245 8,220 10,470 12,730 5,395 4,700 8,995 7,835 14,475 18,395 25,080 31,770 38,460 12,445 20,745 32,520 38,085 51,930 65,780 79,630 12 1,230 1,135 2,050 1,890 3,350 5,255 6,915 8,815 10,720 4,580 4,060 7,635 6,765 12,340 15,880 21,655 27,430 33,205 10,800 18,000 28,515 34,410 46,925 59,440 71,950 Wood Member Compression Capacities TABLE 2.1- SPF: COMPRESSION CAPACITIES FOR SPRUCE PINE FIR 1, 2 Nominal Wall Depth, b3 (in) 4" 6" 8" Nominal Lumber Dimensions Lumber Grade 2x4 2x4 3x4 3x4 4x4 4x6 4x8 4x10 4x12 2x6 2x6 3x6 3x6 6x4 6x6 6x8 6x10 6x12 2x8 3x8 4x8 6x8 8x8 8x10 8x12 No. 2 Stud No. 2 Stud No. 1 No. 1 No. 1 No. 1 No. 1 No. 2 Stud No. 2 Stud No. 1 No. 1 No. 1 No. 1 No. 1 No. 2 No. 2 No. 1 No. 1 No. 1 No. 1 No. 1 Pc⊥ Maximum Pc - Maximum Design Compression Capacity Parallel to Grain (lbs.) 6, 7, 8, 9 Compression Capacity Nominal Wall Height (ft.) 10 Perpendicular to 8 9 10 11 12 Grain (lbs.) 4, 5 2,230 2,230 3,720 3,720 5,205 8,180 10,785 13,760 16,735 3,505 3,505 5,845 5,845 8,180 12,855 17,530 22,205 26,880 4,780 7,970 11,155 17,530 23,905 30,280 36,655 2,930 2,415 4,885 4,030 6,840 10,710 14,060 17,850 21,710 9,600 6,915 16,000 11,525 22,040 25,545 34,835 44,125 53,415 17,875 29,790 40,420 40,930 55,810 70,695 85,580 2,340 1,955 3,895 3,255 5,455 8,550 11,235 14,285 17,375 8,055 6,100 13,425 10,165 18,585 22,840 31,150 39,455 47,760 16,215 27,025 36,880 39,070 53,280 67,485 81,695 1,905 1,605 3,175 2,670 4,440 6,965 9,160 11,655 14,175 6,770 5,310 11,280 8,850 15,665 20,115 27,430 34,740 42,055 14,465 24,110 33,090 36,850 50,255 63,655 77,055 1,575 1,335 2,630 2,225 3,680 5,775 7,600 9,675 11,765 5,725 4,605 9,545 7,670 13,280 17,580 23,970 30,360 36,755 12,770 21,285 29,350 34,330 46,810 59,295 71,780 1,325 1,130 2,210 1,880 3,095 4,860 6,400 8,150 9,910 4,885 3,995 8,145 6,655 11,350 15,340 20,915 26,495 32,075 11,230 18,715 25,895 31,620 43,115 54,615 66,110 TABLE 2.1- SP: COMPRESSION CAPACITIES FOR SOUTHERN PINE 1, 2 Nominal Wall Depth, b3 (in) 4" 6" 8" Nominal Lumber Dimensions Lumber Grade 2x4 2x4 3x4 3x4 4x4 4x6 4x8 4x10 4x12 2x6 2x6 3x6 3x6 6x4 6x6 6x8 6x10 6x12 2x8 3x8 4x8 6x8 8x8 8x10 8x12 No. 2 Stud No. 2 Stud No. 1 No. 1 No. 1 No. 1 No. 1 No. 2 Stud No. 2 Stud No. 1 No. 1 No. 1 No. 1 No. 1 No. 2 No. 2 No. 1 No. 1 No. 1 No. 1 No. 1 Pc⊥ Maximum Pc - Maximum Design Compression Capacity Parallel to Grain (lbs.) 6, 7, 8, 9 Compression Capacity Nominal Wall Height (ft.) 10 Perpendicular to 8 9 10 11 12 Grain (lbs.) 4, 5 2,965 2,965 4,945 4,945 6,920 10,875 14,335 18,290 22,245 4,660 4,660 7,770 7,770 10,875 17,090 23,305 29,520 35,735 6,355 10,595 14,830 23,305 31,780 40,255 48,730 2,980 2,615 4,970 4,360 7,910 12,345 16,180 20,500 24,855 10,165 7,520 16,940 12,530 26,450 30,025 40,940 51,860 62,775 19,750 32,915 50,260 48,185 65,705 83,225 100,745 2,365 2,105 3,945 3,510 6,280 9,820 12,890 16,360 19,855 8,380 6,605 13,970 11,005 21,945 26,820 36,575 46,325 56,080 17,540 29,235 45,060 45,970 62,690 79,405 96,125 1,920 1,725 3,200 2,875 5,100 7,980 10,485 13,325 16,180 6,965 5,730 11,610 9,550 18,305 23,595 32,180 40,760 49,340 15,355 25,595 39,770 43,335 59,095 74,850 90,610 1,590 1,435 2,650 2,390 4,215 6,605 8,685 11,050 13,420 5,850 4,955 9,750 8,255 15,410 20,610 28,105 35,595 43,090 13,365 22,270 34,815 40,340 55,010 69,680 84,345 1,335 1,210 2,225 2,015 3,545 5,555 7,305 9,300 11,295 4,970 4,290 8,280 7,150 13,110 17,975 24,515 31,050 37,585 11,625 19,375 30,420 37,130 50,630 64,130 77,635 Notes 1. Wood compression members are not a Z4 product and are not provided with Z4 Tie-Down Systems. 2. All values assume single species installation. The Engineer of Record is responsible for designs with more than one species or for heights not listed in these tables. 3. Wall depth (b) = 3.5 inches for nominal 4-inch, 5.5 inches for nominal 6-inch, and 7.25 inches for nominal 8-inch wall depths 4. Maximum design compression capacities perpendicular to grain, Pc are based on wood compressive strengths equal to 625 psi for DF-L, 405 psi for HF, 425 psi for SPF, and 565 psi for SP. 5. The Bearing Area factor, Cb, is not included in table values. For bearing areas located 3” or more from the end of the horizontal member, perpendicular to grain capacities, Pc⊥, may be multiplied by the following factor: Thickness of Horizontal Member (in) Cb Factor 1.5 2.5 3.5 5.5 ≥ 6.0 1.25 1.15 1.11 1.07 1.00 6. Maximum design compression capacities parallel to grain, Pc are based on the tabulated wood species, effective length, cross-sectional area, and grade in compliance with the 2012 National Design Specification (NDS). 7. Loads shown are for axial compression of individual single member capacities. Individual capacities may be combined when multiple members are installed, stitch nailing not required. 8. Parallel to grain capacities Pc include a load duration factor, CD. Increase equal to 1.60. 9. Shaded cells represent capacities governed by compression parallel to grain. 10. The lumber effective length (le) for an 8-ft nominal wall height is equal to 92-1/4" for DF-L and 92-5/8" for HF, SPF, and SP. le / b ≤ 50. 15 Concentric Ties Code Reports CT & T2 Z4 Continuity Tie • ESR-3105 • LA City RR 25334 The Z4 “CT” is a steel tube with steel end plates welded to both ends designed to transfer tension and compression forces from one beam to another (Purlin Splice application) or from a beam to a perpendicular wall (Wall Tie application). Connections are made by bolting the tube to a wood member and attaching to a threaded rod for transferring forces. Paired CT Wall Tie Accurate Placement and Installation Step 1: Use the two 3/16” holes provided to nail CT or T2 at desired location on wood member Paired CT Purlin Tie Step 2: Use the CT or T2 as a template to accurately drill holes for bolting Step 3: Make bolted connection to the wood member per plans and specifications Step 4: Make threaded rod connection per plans and specifications. Z4 Tension Tie Sandwiched T2 As Concentric Hold-Down Z4-CT 2 4 - 4 16 The Z4 “T2” is a steel tube with a steel end plate welded to one end designed to transfer tension forces with a single concentric hold-down device. Sandwiched Installations are made by through bolting two wood members with a T2 between. The tube is then attached to a threaded rod to transfer the tension loads. Z4-T2 - 4 8 - 9 Anchor Rod. Dia. (1/8" Increments) Fastening Bolt Dia. (1/8" Increments) Fastening Bolt Quantity Continuity Tie Anchor Rod. Dia. (1/8" Increments) Fastening Bolt Dia. (1/8" Increments) Fastening Bolt Quantity Tension Tie Concentric Ties CT & T2 Dimensions and Fasteners TABLE 3.0- DIMENSIONS AND FASTENERS FOR THE CT & T2 Fastening Bolts 1, 2 Description “T2” Tension Tie “CT” Continuity Tie Model Number Z4-T2-24-4 Z4-T2-43-4 Z4-T2-44-5 Z4-T2-46-8 Z4-T2-48-9S Z4-T2-64-6 Z4-T2-68-11S Z4-T2-84-7 Z4-CT-24-4 Z4-CT-43-4 Z4-CT-44-5 Z4-CT-46-8 Z4-CT-48-9 Z4-CT-64-6 Z4-CT-68-11 Z4-CT-84-7 Qty & Size (2) 1/2” (4) 3/8” (4) 1/2” (4) 3/4” (4) 1” (6) 1/2” (6) 1” (8) 1/2” (2) 1/2” (4) 3/8” (4) 1/2” (4) 3/4” (4) 1” (6) 1/2” (6) 1” (8) 1/2” Anchor Rod Diameter Single Assembly (1 HS Rod) 3 Paired Assembly (2 STD Rods)4, 5 1/2” 1/2” 5/8” 1” 1-1/8” 3/4” 1-3/8” 7/8” n/a n/a 1/2” 1/2” 5/8” 1” 1-1/8” 3/4” 1-3/8” 7/8” Tube Dimensions (in.) Thickness Width Depth Length 1/8” 1/8” 1/8” 3/16” 3/16” 1/8” 3/16” 1/8” 1/8” 1/8” 1/8” 3/16” 3/16” 1/8” 3/16” 1/8” 3” 2-1/2” 3” 4” 5” 3” 5” 3” 3” 2-1/2” 3” 4” 5” 3” 5” 3” 3” 2-1/2” 3” 3” 3” 3” 3” 3” 3” 2-1/2” 3” 3” 3” 3” 3” 3” 2-7/8” 4-7/8” 5” 7-1/4” 10-3/8” 7-1/8” 14-3/4” 9-1/4” 3-1/4” 5-1/4” 5-1/2” 7-3/4” 10-1/4” 7-3/4” 15” 10” Notes: 1. Fastening Bolts must comply with ASTM A307. Standard round washers and hex nuts, for tightening the CT or T2 to adjacent wood member(s), must comply with F844 and A563A respectively. 2.The minimum required distance from the end of the wood member to the centerline of the first bolt is seven bolt diameters. Increasing the end distance has no effect on the allowable tension load. 3. Single (Sandwiched) Assemblies are applicable to Tension Ties (T2) when one Tie is sandwiched between and through-bolted to two wood members. One Tie and one HS rod required. 4. For Paired Assemblies, threaded rods must comply with ASTM F1554 Grade 36 (minimum) connecting the CT with one standard (F844) round washer and one A563A hex nut. For Single (Sandwiched) Assemblies, threaded rod must comply with ASTM A311 Grade 1045 (minimum). 5. Paired Assemblies of Continuity Ties (CT) require two Ties bolted together with a single wood member between. Two Ties and two STD rods required (one per Tie). 17 Concentric Ties CT & T2 Allowable Loads TABLE 3.1-DF-L: CT & T2 ALLOWABLE LOADS WHEN CONNECTED TO DOUGLAS FIR-LARCH 1 Installation 2, 3, 4 Width of Model Number Attached Wood Member (in.) 23,417 23,794 23,417 23,417 23,417 23,417 0.129 19,385 37,382 39,152 37,382 48,114 56,276 19,385 19,385 19,385 19,385 0.114 42,141 42,867 42,867 42,867 0.122 43,612 56,133 61,061 64,036 64,036 64,036 0.210 Z4-CT-24-4 3.5 3,360 5,600 6,235 6,235 6,235 6,235 6,235 0.160 Z4-CT-43-4 3.5 5,010 6,989 6,993 6,997 7,004 7,004 7,007 0.132 12,430 12,457 0.146 18,504 18,592 0.145 24,590 0.152 28,028 0.155 43,240 0.162 Z4-T2-68-11S Z4-CT-44-5 Z4-CT-64-6 Z4-CT-84-7 Z4-CT-46-8 Z4-CT-48-9 Z4-CT-68-11 18,465 18,499 18,533 18,573 18,597 3.5 6,637 11,118 12,395 12,405 12,420 3.5 5.5 3.5 5.5 7.25 / 7.5 5.5 7.25 / 7.5 5.5 7.25 / 7.5 9.25 / 9.5 5.5 7.25 / 7.5 9.25 / 9.5 11.25 / 11.5 13.25 / 13.5 7,138 9,679 7,138 10,662 12,377 11,897 16,395 11,897 17,769 21,300 16,453 16,464 15,576 20,048 21,513 15,576 20,048 24,317 27,506 29,652 14,276 18,330 14,276 21,323 23,892 19,744 19,817 18,691 24,057 25,939 18,691 24,057 29,180 33,008 36,167 16,656 18,383 16,656 18,442 18,442 21,137 22,683 24,057 24,241 24,381 27,776 27,804 30,020 41,858 43,240 30,020 41,858 49,850 56,388 64,541 32,216 9,749 9,345 12,029 12,591 9,345 12,029 14,590 16,504 16,622 23,034 23,184 21,806 28,067 30,460 21,806 28,067 34,044 38,509 42,901 43,240 32,216 46,736 50,119 61,999 64,593 7.25 / 7.5 6,235 7,009 12,449 Displacement @ Allowable Tension Load (in.) 7 19,385 31,151 36,671 31,151 40,095 52,474 Z4-T2-84-7 Z4-T2-46-8 Z4-T2-48-9S 18 Thickness of Attached Wood Member (in.) 2.5 3 3.5 5.125 5.5 6,235 6,235 6,235 6,235 6,235 7,001 7,001 7,005 7,007 7,009 12,422 12,432 12,436 12,445 12,449 1.5 4,984 6,457 9,904 14,276 14,637 14,276 19,077 19,385 18,691 24,057 18,691 24,057 31,833 Z4-T2-64-6 Paired CT Wall & Purlin Ties 5, 6, 3.5 3.5 3.5 3.5 5.5 3.5 5.5 5.5 5.5 7.25 / 7.5 5.5 7.25 / 7.5 9.25 / 9.5 Z4-T2-24-4 Z4-T2-43-4 Z4-T2-44-5 Sandwiched T2 Concentric Hold Down Allowable Tension Load (lbs.) 18,597 0.085 0.102 0.108 0.128 43,931 63,731 0.148 64,593 Notes: 1. Values in this table are Allowable Stress Design (ASD) for No. 1 grade Douglas Fir-Larch and include a 1.60 stress increase factor, CD, for short- term load duration as permitted by the National Design Specification (NDS 2012). 2. Paired Assemblies of Continuity Ties (CT) require two ties to be connected to a standard grade anchor rod and the ties bolted together with a single wood member between. 3. Single (Sandwiched) Assemblies are applicable when one Tension Tie (T2) is sandwiched between and through-bolted to two wood members. One Tie and one HS rod and bolts required. 4. For compression loading the minimum required distance from the end of the wood member to the centerline of the first bolt is seven bolt diameters. allowable tension load. 5. The capacity of the anchor rod must be equal to or greater than the allowable tension load of the Tie being attached. See table 3.2 for anchor rod capacities. 6. Allowable tension loads consider • Tested CT or T2 capacity divided by 2.5 • Maximum anchor rod capacity • Cross sectional area of the attached wood member where it is drilled for the bolted connection 7. Displacement at tension loads less than the respective allowable load are determined by proportioning the design load to the allowable load. Shrinkage of supporting wood members and anchor rod elongation are the responsibility of the Building Design Professional. Tabulated displacement values consists of: a) Vertical displacement of the CT or T2 Tie due to rotation. b) Fastener slip where the CT or T2 Tie connects to the wood member. Concentric Ties CT & T2 Rod Capacities TABLE 3.2- ROD DESIGN TENSION AND COMPRESSION CAPACITIES FOR THE CT & T2 1 Allowable Compression Capacity (lbs.) 3, 4, 5 Installation Anchor Rod Grade 2 Quantity Tension Diameter (in.) Allowable Capacity (lbs.) Maximum Unsupported Length, L (in.) 6 12 Single (Sandwiched) Assembly (1 Tie) Paired Assembly (2 Ties) HS STD 1 2 1/2” 5/8” 3/4” 7/8” 1” 1-1/8” 1-1/4” 1-3/8” 1/2” 5/8” 3/4” 7/8” 1” 1-1/8” 1-1/4” 1-3/8” 8,468 13,231 19,052 25,932 33,870 42,867 52,922 64,036 8,541 13,346 19,218 26,157 34,165 43,240 53,383 64,593 18 24 30 36 42 370 936 2,052 3,910 6,728 10,684 17,224 24,162 272 688 1,508 2,872 4,944 7,850 12,654 17,970 n/a in Compression 3,200 6,448 10,741 15,863 21,724 28,188 36,689 44,400 1,478 3,746 7,778 12,684 18,333 24,596 32,868 40,397 830 2,108 4,616 8,795 14,252 20,313 28,347 35,681 532 1,348 2,954 5,630 9,690 15,317 23,134 30,279 Notes: 1. The values in this table are Allowable Stress Design (ASD), excluding a 1.33 duration of load stress increase factor, CD. 2. STD indicates rods complying with ASTM F1554 Grade 36. HS indicates rods complying with ASTM A311 Grade 1045. 3. When using Continuity Ties (CT) to transfer compression loads, the Building Design Professional is responsible for checking the wood member(s) design capacity for the most critical load combination (i.e. bending about one or both principal axes and axial compression). 4. Compression capacities shown in blue apply to KL / r > CC , where: r = (DR - .9743 / n) / 4, where n = threads per inch, Cc = (2π2 E / Fy)1/2, E = Modulus of Elasticity of rod, (29 x 106) and Fy = yield strength of rod steel (36 ksi). 5. Compression capacities assume a slenderness factor, K, of 1.00 or for installations with both ends of the rod pinned. When both ends of the rod are approximately fixed, K = 0.65. 6. Compression capacities are for Continuity Ties (CT) spaced no greater than the specified maximum unsupported length. 19 Tie-Down System 20 Installation Photos MiTek Builder Products Introducing MiTek Builder Products MiTek Builder Products is a new division of MiTek USA, Inc. that has been formed to unify related products, technologies and services around a single goal: To serve our customers seamlessly with industry-leading technological innovation, products and support, and a passionate commitment to our customers’ success. A Streamlined Team The new MiTek Builder Products division combines three companies that were previously independent: USP Structural Connectors, Hardy Frame Shear Walls, and Z4 Continuous Tie-Down Systems. Like other MiTek product lines, the Builder Products division is aligned in its purpose, supported by a centralized infrastructure of manufacturing capacity, software development and technical support in the market. Better Technology, Better BuildingSM The MiTek Builder Products division serves the construction industry with an extensive offering of innovative products and solutions. These are designed to provide a full range of structural connections and design tools. Products, software and construction methods work together to offer an optimized structure and a more efficient construction process. • Designers will recognize the advantage of support and solutions across the product lines. • Builders benefit from specified solutions that dovetail from one component to the next throughout the load path of the building. • Lumber and Building Material Dealers will experience increased crossover solutions when providing ‘whole-house’ approach. The Z4 “Continuous Tie-Down System” features Cinch Nut™, an innovative wood shrinkage/deformation take-up device. It ratchets down all threaded rods in the non-load direction as framing elements change dimensions over time. Hardy Frame™ is the industry leading pre-fabricated shear wall system. Building design professionals specify the Hardy Frame System not only to resist wind and earthquake loads, but to also maximize wall openings economically. The Hardy Frame product line includes Panels, Brace Frames and Moment Frames. The USP brand offers builders and engineers a comprehensive line of code evaluated connectors, framing hardware, fasteners, anchors and epoxy solutions for the residential, commercial construction and DIY markets. USP offers more than 4,000 SKUs backed by innovative software solutions, professional engineering, technical support, and a sales team across the US and Canada. The MiTek Story MiTek resources run deep. We began with the innovation of the first ‘Gang-Nail’ plate in 1954 then evolved through the acquisition and merging of a range of high quality companies. Today we are recognized as the world’s leading supplier of software, structural connectors, engineering services and automated manufacturing equipment to the component manufacturing industry. MiTek’s reputation as an innovative market leader, committed to the success of its customers, continues to grow. Owned by Warren Buffett’s Berkshire Hathaway, MiTek’s growth and acquisitions have allowed us to pursue a vision that extends to the residential sector and beyond. Today our company also serves the commercial and industrial construction sectors with a consistent character of innovation, lasting values and enduring relationships. Your success is our success.SM 21 MiTek Builder Products Shear Walls Hardy Frame® Code Evaluations ICC-Evaluation Service ESR-2089 LA City Research Report RR-25759 Hardy Frames has been leading the pre-manufactured shear wall industry from its beginning. We were the first to be recognized by ICBO-ES and LA City, first to gain approval for multi-story applications, first Balloon Wall application and first to be recognized to comply with the 2003 and 2006 IBC and IRC Building Codes. Today we are the first, and only, to offer a 9 inch Panel width and a Balloon Wall application that is fully assembled in the manufacturing plant and ships as a one piece unit. All Hardy Frame® Panels and Brace Frames are code listed and include installations on concrete, raised floor and upper floor systems. “Back to Back” installations provide two times the allowable shear value Hardy Frame® HFX-Series Panels • Panels are available in 9, 12, 15, 18, 21 and 24 inch widths • Standard Heights range from 78 inches for portal applications to 20 feet for Balloon Walls • Custom heights are manufactured routinely • R Value for design = 6.5, Cd = 4.0 • With proper detailing and anchorage “Back to Back” installations provide two times the allowable shear value without increasing the wall width Hardy Frame® HFX-Series Brace Frames • Brace Frames are available in 32 and 44 inch widths • Standard Heights range from nominal 8 to 13 feet • Custom heights are manufactured routinely • R Value for design = 6.5, Cd = 4.0 • For a given shear load, installing a wider shear wall results in reduced overturning Hardy Frame® Brace Frame Hardy Frame® Balloon Wall Hardy Frame® Panel Hardy Frame® Panel Back to Back Template Kit (HFXTK) Includes: • One Template for accurate anchor spacing and alignment • One Bolt Brace for installation at embed end of anchors to prevent independent sway while pouring concrete • Two 1-1/8 inch diameter hold down anchors • Six Grade 8 hex nuts • Two hardened round washers • Two 1/2 x 3 x 3 plate washers are included when high strength (HS) anchors are specified Hardy Frame® Bearing Plate (HFXBP) 22 • 3/4” thick x 3 1/2” wide ASTM A36 steel • Length extends 3” beyond Panel edges. Check for outside corner conditions! • Reduces wood deformation from overturning forces • Reduces effects of shrinkage by eliminating bottom plate Note: The allowable values in raised floor and upper floor tables assume installation of HFXBP. Installation without a HFXBP may result in a reduction of allowable loads. www.hardyframe.com • 1-800-754-3030 Hardy Frame® Moment Frame MiTek Builder Products SidePlate Code Evaluations Included in the Standard AISC 358 ICC-Evaluation Service ESR-1275 Report LA City Research Report RR-25393 Hardy Frames introduced the first standardized, prefabricated Special Moment Frame in 2006. Since then we have delivered thousands of Moment Frames that have been successfully installed. Our Special Moment Frames provide maximum structural capacities and enable large openings in architectural design. Hardy Frame® Special Moment Frames utilize the SidePlate moment connection which has now been approved by the Connection Prequalification Review Panel (CPRP) for inclusion in the AISC 358 Prequalified Moment Connection Standard. Typically, Hardy Frame® Moment Frames are delivered to the jobsite in one-piece, completely prefabricated with wood nailers attached, and ready to be installed with no assembly. No field welding and or special inspection is required. On production framing jobs the Hardy Frame® Moment Frame can’t be beat. We have delivered truckload quantities of up to 30 Moment Frames that were installed in a single day. That is an accomplishment that cannot be matched by conventional or assembly-required moment frames. Custom Sizes and Custom Calculations We offer over 300 standard dimension Moment Frames, but we don’t stop there. We also offer calculations and solutions for sizes beyond our standard listing. We commonly provide solutions for two-story and multi-story frames as well as for fixed based connections. At Hardy Frames we understand that Moment Frames require job-specific considerations. We work with contractors to meet their needs without treating adjustments as a custom order. Moment Frame Template Kits Double nut at HFT Template Kits are included with the purchase of the Hardy Frame® Moment Frame and are a stock item that can nce Distatch is ured o Measnotch to nrame be shipped within one business day. The Kit includes all F fromMoment nsion ime W d embed anchors, nuts, washers and Templates so the Double nut at bolt brace concrete pour can proceed prior to the Moment Frame delivery. Correctly locating the anchors is easy with a slot provided in the Template to measure the “Win”, (inside steel-to-steel) dimension. www.hardyframe.com • 1-800-754-3030 IN 23 MiTek Builder Products USP Structural Connectors MiTek is the leading provider of structural connectors, software, and a range of engineered products to component manufacturers and building material suppliers in the residential construction industry. The USP legacy of innovation dates back to 1933 when the original timber connectors were conceived and standardized. Over the years the legacy grew by combining TECO, Silver, Lumberlok, Kant Sag, Hughes, Covert and Renown, some of the most recognizable brands in the industry. These brands combined through the years to eventually form one company - “United Steel Products”. In March, 2011 USP Structural Connectors was purchased by MiTek USA, Inc., a Berkshire Hathaway subsidiary. Today, USP Structural Connectors is the branded product line from MiTek that provides a complete line of code approved engineered structural connectors, anchoring solutions, and design software solutions for the residential, commercial and DIY markets. The USP product line offers more than 4,000 SKUs that are made in the USA, and backed by professional engineering technical support and a sales team that serves the United States and Canada. Over 4000 SKUS made in the USA Gold Coat offers 2X the Corrosion Protection FWH Series Fire Wall Hanger attaches floor framing to two-hour, fire-rated wall assemblies in wood-frame construction 24 Complete line of high-performance epoxy applications THFI joist hanger combines ease of installation with the flexibility of a face mount hanger USP Customer Service 1-800-328-5934 • uspconnectors.com Typical Details Tie-Down System CINCH NUT (CNX) INSTALLATION C1 BEARING PLATE WASHER (PW) C2 NOTCHES INDICATE HIGH STRENGTH WITNESS HOLE HIGH STRENGTH COUPLER HIGH STRENGTH REDUCER WITNESS HOLE STANDARD COUPLER STANDARD REDUCER WITNESS HOLE THREAD ROD IN HALF WAY FROM EACH SIDE, VISIBLE THROUGH SITE HOLE FULLY SEAT LARGE DIA. ROD FIRST, FULLY SEAT SMALL DIA. ROD SECOND SO REDUCER CANNOT TURN 25 NOTE: ROD THREADS SHALL FULLY ENGAGE COUPLER COUPLER NUT (CNW) C3 Z-ROD (ZR) C4 Typical Details Tie-Down System COMPRESSION POST LOCATION C5 ALLOWABLE ROD OFFSET C6 POSTS OVER BEARING PLATE WASHER C7 ANCHOR @ BEAM C8 26 Typical Details BRIDGE TERMINATION OPTION Tie-Down System C9 STRAP TERMINATION OPTION C10 27 TOP PLATE TERMINATION OPTION C11 Z-ROD THREAD BLOCKING C12 Typical Details Tie-Down System COMPRESSION POST LAYOUT Details with built-up 2x4 and 2x6 member posts are also available C13 INSTALLATION @ COMMON CORNER C15 COMPRESSION POST EDGE NAILING C14 INSTALLATION @ INTERSECTION C16 Details with built-up 2x4 and 2x6 member posts are also available 28 Details with built-up 2x4 and 2x6 member posts are also available Details with built-up 2x4 and 2x6 member posts are also available Typical Details AT-32 ELEVATION @ BEARING JOISTS Tie-Down System C17 AT-32 SECTION @ BEARING JOISTS C18 29 AT-32 ELEVATION @ HANGING JOISTS C19 AT-32 SECTION @ HANGING JOISTS C20 Typical Details Tie-Down System AT-65 ELEVATION @ BEARING JOISTS C21 AT-65 SECTION @ BEARING JOISTS C22 AT-65 ELEVATION @ HANGING JOISTS C23 AT-65 SECTION @ HANGING JOISTS C24 30 Typical Details Tie-Down System + _ 9" ANCHOR W/ PLATE WASHER @ DECK Intentionally Left Blank + _ 9" C25 ANCHOR W/ NUT @ DECK C26 Intentionally Left Blank 31 Typical Details PAIRED CT - WALL TIE Concentric Ties C27 PAIRED CT - PURLIN SPLICE Intentionally Left Blank 32 SANDWICHED T2 - HOLD DOWN C29 C28 Better Technology. Better Building. CNX-5 BPW-7 108” Option 1 2x4 DF No.2 Option 2 2x6 DF No.2 Ea. Side Post 2x4 DF No. 2 (1) 2x6 DF No. 2 (1) Ei. Side Post None 2x4 DF No. 2 (1) 108” Component Wall Plates Level Summary ZR5x9 STD LEVEL 5 CNW8/5 STD CNX-8 BPW-11 120” 12” 108” Option 1 2x4 DF No.2 Option 2 2x6 DF No.2 Ea. Side Post 4x4 DF No.1 (1) 3x6 DF No. 2 (1) Ei. Side Post None 3x4 DF No. 2 (1) ZR8x10 STD CNW 8 STD LEVEL 4 120” Wall Plates 12” CNX-8 BPW-5 2x4 DF No.2 120” Option 2 2x6 DF No.2 Ea. Side Post 4x6 DF No.1 (1) 3x6 DF No. 2 (1) ZR8x10 STD Ei. Side Post 2x6 DF No. 2 (1) CNW9/8 STD None LEVEL 3 108” Wall Plates Option 1 12” CNX-9 BPW-5 Accumulated Tension (lbs) 6000 6,675 Additional Compression (lbs) 500 8,040 Accumulated Compression (lbs) 6500 8,040 Total Level Deflection (in) 0.167 0.200 Total Rod Elongation (in) 0.088 0.200 Design Control Level Tension (lbs) 9000 10,750 Accumulated Tension (lbs) 15000 17,080 Additional Compression (lbs) 1000 17,880 Accumulated Compression (lbs) 16500 17,880 Total Level Deflection (in) 0.175 0.200 Total Rod Elongation (in) 0.085 0.200 Design Control Level Tension (lbs) 1000 4780 Accumulated Tension (lbs) 16000 17,080 Additional Compression (lbs) 500 21,020 Accumulated Compression (lbs) 18000 21,020 Total Level Deflection (in) 0.152 0.200 Total Rod Elongation (in) 0.091 0.200 Design Control Level Tension (lbs) 4780 4,780 Wall Plates Option 1 2x4 DF No.2 Option 2 2x6 DF No.2 Ea. Side Post 4x6 DF No. 1 (1) 6x4 DF No. 1 (1) Ei. Side Post 2x6 DF No. 2 (1) ZR9x10 STD CNW12/9 STD LEVEL 2 3x4 DF No. 2 (1) 120” Level Summary Component 108” 7,690 Level Summary Component 120” Control 6000 Level Summary Component 120” Design Level Tension (lbs) 20780 21,620 2220 25,490 Accumulated Compression (lbs) 25000 25,490 Total Level Deflection (in) 0.188 0.200 Total Rod Elongation (in) 0.093 0.200 Design Control Status Status Status 12” CNX-12 BPW-6 Accumulated Tension (lbs) Additional Compression (lbs) Status Option 2 2x6 DF No.2 Ea. Side Post 4x8 DF No. 1 (1) 6x4 DF No.1 (1) Ei. Side Post 3x6 DF No. 2 (1) 3x4 DF No. 2 (1) ZR12 x 10 STD CNW16/12 STD A36 2 x 24 EXAMPLE (QTY: 1) 9” 108” Option 1 2x4 DF No.2 LEVEL 1 120” Component Wall Plates 120” Level Summary Level Tension (lbs) 5655 5,660 Accumulated Tension (lbs) 26435 38,435 Additional Compression (lbs) 1345 32,100 Accumulated Compression (lbs) 32000 32,100 Total Level Deflection (in) 0.181 0.200 Total Rod Elongation (in) 0.067 0.200 Status 33 Additional MiTek Builder Products Tools and Publications USP Structural Connectors Product Catalog Pro b l e m Catalog Solved! Product The USP brand offers builders and engineers code evaluated connectors, framing hardware, fasteners and anchors. The USP product catalog is a comprehensive guide to USP's entire product line. It includes product and application illustrations, installation instructions, fastening schedules and load ratings. US and Canadian versions. Available as an iPad App. HFX-Series Catalog The Hardy Frame® HFX-Series Product Catalog provides complete information for designing and detailing with HFX-Series products. This catalog provides a complete listing of all HFX-Series Panels, Brace Frames and Accessories, product descriptions, photographs, allowable design values for various bearing surfaces, Typical Installation Details and standard anchorage information Installation Guide The Hardy Frame® Installation Guide was written specifically for Suppliers and Installers. This publication provides all HFX-Series model numbers, dimensions, bolt and screw patterns, connectors, installation illustrations, attachments with self-tapping screws and information regarding Template Kit (HFXTK) and Floor to Floor Connector Kit (HFTC)components. Moment Frame Catalog Includes instructions for designing with Hardy Frame® Moment Frames, allowable values, typical Installation details and a Non-Standard form for submittal when project conditions require a custom design. USP SpecifierTM Free project management and cost control software simplifies access to information on over 3000 structural connectors through an intuitive and graphical desktop interface. SAPPHIRETM MiTek SAPPHIRETM Supply MiTek Supply, our 3D whole-house framing design software, is tailored to the lumber dealers’ design and estimating operations. Its companion module, SAPPHIRE Viewer, shares the 3D model with builders and trades, creating an efficient and accurate estimating process. SAPPHIRE Supply is available exclusively to dealers stocking USP Structural Connectors. (951) 245-9525 ©2015 MiTek All Rights Reserved www.mitekbuilderproducts.com