IOM - AHI Carrier
Transcription
IOM - AHI Carrier
51AKP OWNER’S MANUAL BEDIENING EN ONDERHOUD MANUALE DELL’UTENTE O MANUEL DE L’UTILISATEUR MANUAL DO UTILIZADOR GEBRAUCHSANWEISUNG DRIFT- OCH SKÖTSELINSTRUKTION MANUAL DEL USUARIO KÄYTTÄJÄN KÄSIKIRJA 51AKP ENGLISH Portable air conditioner with electronic control ITALIANO Climatizzatore portatile con comando elettronico FRANÇAIS Climatiseur mobile à commande électronique DEUTSCH Fahrbares klimagerät mit elektronikregelung ESPAÑOL Equipo portátil de aire acondicionado con mando electrónico NEDERLANDS Portable airconditioner met elektronische regeling K PORTUGUÊS Unidade de Ar Condicionado tipo portátil com controle electrónico SVENSK Portabel luftkonditionering med elektronisk styrning SUOMI Siirrettävä jäähdytyskoje elektronisillä säätölaitteilla This manual applies to the following models Page Remote Control ..................................... 1 Control panel ......................................... 1 Accessories supplied ............................ 2 General information .............................. 2 Preparing to use (stand-alone) ......... 3/4 Cooling with dehumidification .............. 5 Dehumidification .................................... 5 Fan only ................................................. 6 Auto Mode .............................................. 6 Sleep Mode ............................................ 7 Timer programming ............................ 7/8 In case of ............................................... 9 Cleaning ................................................. 9 Instruction to install drainage pipe accessories .......................................... 10 51AKP210E 51AKP300E 51AKP220M 51AKP240M 51AKP310M 51AKP260H Read this instruction manual thoroughly before using the air conditioner. Remote Control M L N O AUTOFAN A B C D E F G H I J K L M N O P Q OPER AUTO K C J P ON AM OFF PM A Q ON/OFF TEMP- C D E G H MODE B C TEMP+ FAN SLEEP CLOCK F TIME + H T-ON TIME - CANCEL - ON/OFF button Mode selector Temperature selection button Fan speed selection button Sleep function button Clock Button Timer- on button Timer selection button Timer cancel button Selected temperature display Auto mode icon Cooling mode icon Dehumidification mode icon Fan speed display Fan mode icon Sleep mode icon Timer/Clock display ENGLISH Contents I Control panel 8 9 7 10 11 12 ON/OFF SLEEP MODE FAN TEMP SET TEMP FAN M DRY COOL AUTO TIMER SLEEP ON OFF 1 1 2 3 4 5 - 2 ON-OFF button Mode selector Fan speed selection button Temperature selection button Timer selection button 3 SET TIME LOW MID 13 6 7 8 9 10 - HIGH 14 4 Sleep function button Selected temperature display Fan mode icon Dehumidification mode icon Cooling mode icon 5 6 11 12 13 14 - Auto mode icon Sleep mode icon Timer display Fan speed display GB - 1 Accessories supplied STAND-ALONE 1 2 3 1. Air outlet vent 2. Flexible hose 3. Front and back plastic pipe ends 4. Fastening strap with suction cup 4 General information Unit installation Read this instruction manual thoroughly before installing the unit and keep it for further consultation even after installation. • This unit complies with the following directives: - low-voltage 73/23/CEE; - electromagnetic compatibility 89/336/CEE; - PED Pressure Equipment 97/23/CE; - energy labelling 2002/31/CE; - RoHs directive compliance. • For safety reasons, installers are required to read the general information carefully. • Follow all the instructions below to ensure safety. • Inspect the unit for damage due to improper transport. In case of damage, file an immediate claim with the shipping company. • Do not install or use damaged equipment. • To prevent fire, explosion or injury, do not operate the unit near dangerous substances or close to naked light equipment. • Ensure that national safety code requirements have been followed for the main supply circuit. Follow all current national safety code requirements for the installation. • Make sure a connected ground wire is in place. • Check that voltage and frequency of the mains power supply are those required for the unit to be installed; the available power must be adequate to operate any other appliances connected to the same line. Models 51AKP300E and 51AKP310M can be connected only to a supply with system impedance no more than 0.424ohm. • The manufacturer declines any liability from damage resulting from modifications in the unit or errors in the electrical or hydraulic connections. Failure to observe the installation instructions, or use of the unit under conditions other than those indicated in the table “Operating limits” of the unit owner’s manual, will immediately invalidate the unit warranty. • It is recommended to install a circuit breaker or a 10 A safety fuse for STANDALONE units. Unit operation • This appliance has an automatic function of ‘unit restart’ (in the last GB - 2 mode selected) after an AC power interruption. • In order to avoid electric shock, fire or injury, stop the unit in case of abnormal events (such as smell of burning) and call Carrier Service for further instructions. • Do not place containers filled with liquids or other objects onto the unit. Maintenance WARNING: disconnect the mains power supply prior to any maintenance operations or prior to handling any internal parts of the unit. • The appliance must be maintenanced every one year. • Use of accessories that are not expressly recommended by the manufacturer can result in injuries and harm.Therefore use only original accessories. • A routine maintenance should be carried out on the unit to check the correct operation of the electric connections and protection devices. • Maintenance operations must be carried out by specially trained personnel. • Do not attempt to repair, move, modify the unit on your own. To avoid electric shock or fire make sure these operations are carried out by qualified personnel only. • Contact the qualified service if one of the following events takes place: - hot or damaged power supply cable; - unusual noise during operation; - frequent operation of the protection devices; - unusual smell (such as smell of burning). Choosing the installation site • Choose an area free from obstructions which may cause irregular air distribution and/or return. • Choose a position that allows for the clearances required. The distance between the return air grills and any walls, furniture or obstructions of all kinds must be at least 50 cm. • Look for a position in the room which assures the best possible air distribution. • Only use the appliance inside and for its designated purpose. • The appliance shall be installed in accordance with national wiring regulations. Positions to avoid: • Exposed to direct sun. • Too close to heat sources. • On humid walls or positions with water hazard, e.g. laundry premises. • Exposure to oil vapours (e.g. kitchens, workshops). • Where curtains or furniture may obstruct free air circulation. • The appliance must not be installed in laundry rooms. • The appliance must be positioned so that the plug is accessible. Additional cares • Keep out of reach of children. • Do not obstruct the sides, front and rear grille with curtains or other objects. Do not put objects on the unit. • Do not insert hands or anything else into the air inlet or outlet, • Keep the unit more than 1m far from TV to avoid electromagnetic wave interference. • Never incline or overturn the unit. • Never spray insecticide or other gases to avoid deformation of the unit. • The appliance should always be moved or transported in a vertical position.(Beware: Plug out the power supply before moving) Unit disposal: • At the end of its life, the air conditioner must be delivered to a special collection centre or to the dealer for the refrigerant disposal. • All of the manufacturing and packaging materials used for this unit are compatible with the environment and can be recycled. • Dispose of the packaging material in accordance with local requirements. • DISPOSAL:Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. STAND-ALONE unit performance: The unit is suitable for operation within the following temperature limits according to the standards: Cooling: (EN14511:2004) Max. 35°C d.b.* /24°C w.b.* Min. 21°C d.b.* /15°C w.b.* Dehumidification: Max. 32°C d.b.* / 24°C w.b.* Min. 18°C d.b.* / 14°C w.b.* * d.b. - dry bulb temperature * w.b. - wet bulb temperature STAND-ALONE Preparation for: cooling with dehumidification ENGLISH Air flow Air flow Install the flexible hose onto the air conditioner. To improve the air conditioner performance make sure that: - the internal tips of the flexible hose are turned as shown in the picture; - the hose is stretched as little as possible; - the hose is not bent, folded or throttled. Move the air conditioner close to the window, stretching the hose as little as possible (max. extension 2000 mm). To open the window as little as possible, place the air outlet vent onto the flexible hose and place them outside the window. Make sure the flexible hose is not kinked or curved too tightly and that it is placed on a supporting surface (windowsill, floor...). Hold the hose end in position with the fastening strap and suction cup. Ensure that the expulsion of hot air from the pipe is free from obstructions. If required, the air conditioner can be installed through a porthole in the window or through a hole in the wall follow the instructions in the manual relating to this component. (Accessory not included) GB - 3 STAND-ALONE Preparation for: dehumidification With the unit in the dehumidification mode, extract the flexible hose from the air conditioner and place it as shown in the picture. If you want to use a flexible hose and direct the hot air flow according to your needs, place the hose on a supporting surface. The dehumidification only function should be used if you want to remove moisture from the room air without lowering the temperature. STAND-ALONE Preparation for: dehumidification Rear plate Drainage hole Clamp Rubber plug Clamp In COOL or DRY mode the condensation water is collected in the water tank. When the water tank is full, LCD displays error code H8 and the unit stops. To restart you need to empty the water tank and to stop the unit for 3 minutes. Plug out the power cord before empty the water tank. To empty the water tank ,pull out the rubber plug of the pipe, take out the clamp and drain the water in a base pan. After that, reinsert the plug into pipe to prevent leakage of condensation water and fix the drainage pipe in the clamp. STAND-ALONE Drainage pipe Preparation for: fan only If the air conditioner is to be used in the fan only mode (ventilation) the flexible hose should be inserted with the shortest length and bend so that the air flow coming out from the air conditioner is perpendicular to the floor. GB - 4 CONTROL PANEL Cooling with dehumidification ENGLISH L N 1 2 3 7 10 4 AUTOFAN OPER AUTO ON/OFF SLEEP MODE FAN FAN M TEMP SET TEMP DRY COOL AUTO TIMER ON AM OFF PM SLEEP A C D ON OFF SET TIME LOW MID C J HIGH ON/OFF MODE TEMP- TEMP+ FAN SLEEP CLOCK T-ON 14 TIME - • Switch on the unit by pressing button 1. • Using the function selector, button 2, select the cooling mode. The cooling icon 10 illuminates on the display. • By pressing the temperature selector, button 4, select the desired temperature which will appear on the display 7. • Using the fan speed selector, button 3, select the fan speed which may be low, medium or high. Display 14 shows the selected speed. CONTROL PANEL B C TIME + CANCEL • Switch on the unit by pressing button A. • Using the function selector, button B, select the cooling mode. The cooling icon L illuminates on the display. • By pressing the temperature selector, buttons C, select the desired temperature which will appear on the display J. • Using the fan speed selector, button D, select the fan speed which may be low, medium or high. Display N shows the selected speed. Dehumidification M 1 2 9 AUTOFAN OPER AUTO ON/OFF C SLEEP MODE M FAN TEMP SET TEMP FAN DRY COOL AUTO TIMER ON OFF SET TIME LOW MID ON AM OFF PM SLEEP HIGH A ON/OFF TEMP- MODE B TEMP+ FAN SLEEP CLOCK T-ON TIME - • Switch on the unit by pressing button 1. • Using the function selector, button 2, select the dehumidification mode. The dehumidification icon 9 illuminates on the display. CANCEL TIME + • Switch on the unit by pressing button A . • Using the function selector, button B, select the dehumidification mode. The dehumidification icon M illuminates on the display. GB - 5 CONTROL PANEL Fan only N O 1 2 3 8 AUTOFAN OPER AUTO ON/OFF C SLEEP MODE FAN FAN M TEMP SET TEMP DRY COOL AUTO TIMER ON AM OFF PM SLEEP ON A OFF SET TIME LOW MID ON/OFF MODE HIGH TEMP- D FAN SLEEP 14 B TEMP+ CLOCK T-ON TIME - • Switch on the unit by pressing button 1 . • Using the function selector, button 2, select the fan mode. The fan icon 8 illuminates on the display. • Using the fan speed selector, button 3, select the fan speed which may be low, medium or high. Display 14 shows the selected speed. CONTROL PANEL CANCEL TIME + • Switch on the unit by pressing button A . • Using the function selector, button B, select the fan mode. The fan icon O illuminates on the display. • Using the fan speed selector, button D, select the fan speed which may be low, medium or high. Display N shows the selected speed. Auto Mode K AUTOFAN 1 2 11 OPER AUTO C ON/OFF SLEEP MODE M FAN TEMP SET TEMP FAN DRY COOL AUTO ON AM OFF PM TIMER SLEEP A ON/OFF MODE ON B OFF SET TIME LOW MID HIGH TEMP- TEMP+ FAN SLEEP CLOCK T-ON TIME - CANCEL TIME + • Switch on the unit by pressing button 1 . • Using the function selector, button 2, select the auto mode. The auto mode icon 11 illuminates on the display. The computer will automatically adjust the cooling according to the room temperature. GB - 6 • Switch on the unit by pressing button A . • Using the function selector, button B, select the auto mode. The auto mode icon K illuminates on the display. The computer will automatically adjust the cooling according to the room temperature. CONTROL PANEL Sleep Mode ENGLISH AUTOFAN 1 2 12 6 ON/OFF C FAN FAN M TEMP SET TEMP DRY COOL AUTO TIMER A ON/OFF TEMP- OFF SET TIME MID MODE B SLEEP ON LOW P ON AM OFF PM SLEEP MODE OPER AUTO HIGH TEMP+ FAN E SLEEP CLOCK T-ON TIME - • Switch on the unit by pressing button 1. • Using the function selector, button 2, select the preferred mode. • When the unit is running, press sleep button 6. The Sleep mode 12 icon illuminates on the display. Repress it to stop the function. • The unit increases the cooling temperature 1°C every hour. After 2 hours it keep the set point. • Sleep function doesn’t work in Auto mode. CONTROL PANEL CANCEL • Switch on the unit by pressing button A . • Using the function selector, button B, select the preferred mode. • When the unit is running, press sleep button E. The Sleep mode P icon illuminates on the display. Repress it to stop the function. • The unit increases the cooling temperature 1°C every hour. After 2 hours it keep the set point. • Sleep function doesn’t work in Auto mode. Timer programming AUTOFAN ON/OFF C ON AM OFF PM SLEEP M FAN TEMP SET TEMP FAN DRY COOL AUTO TIMER OPER AUTO 5 MODE TIME + A ON/OFF TEMP- SLEEP Q MODE B TEMP+ ON OFF SET TIME LOW MID FAN HIGH 13 Timer programming when switching on: • Press the timer selection button 5 to set in how many hours the unit will start. Timer setting range is between 0,5-24 h. Time will appear on display 13. • When starting the unit works in the previous mode SLEEP G H CLOCK T-ON TIME - CANCEL TIME + H Timer programming when switching on: • Switch on the unit by pressing button A . • Using the function selector, button B, select the preferred mode • When the unit is running, press the timer-on button G. Press buttons H to set in how many hours the unit will start. Timer setting range is between 0,5-18 h. Time will appear on display Q. • When starting the unit works in the previous mode GB - 7 CONTROL PANEL Timer programming AUTOFAN 1 2 5 ON/OFF C FAN TEMP SET TEMP TIMER A M FAN DRY COOL AUTO ON/OFF TEMP- OFF SET TIME MID Q MODE SLEEP ON LOW P ON AM OFF PM SLEEP MODE OPER AUTO B TEMP+ HIGH FAN E SLEEP H TIME - CANCEL TIME + CLOCK T-ON 13 Timer programming when switching off: • Switch on the unit by pressing button 1 . • Using the function selector, button 2, select the preferred mode • When the unit is running, press the timer selection button 5 to set in how many hours the unit will stop. Timer setting range is between 0,5-24 h. Time will appear on display 13. Timer programming when switching off: • Switch on the unit by pressing button A . • Using the function selector, button B, select the preferred mode • When the unit is running, press sleep button E. The Sleep mode P icon illuminates on the display. • Press buttons H to set in how many hours the unit will stop. Timer setting range is between 0,5-18 h. Time will appear on display Q. AUTOFAN OPER AUTO C ON AM OFF PM ON/OFF TEMP- Clock set: • Press clock button F till the timer display Q starts blinking • Press buttons H to set the clock. • Once adjusted, repress clock button F to save the settings. GB - 8 H Q MODE TEMP+ FAN SLEEP CLOCK F T-ON H TIME - CANCEL TIME + H In case of… ENGLISH If the unit appears not to be operating correctly, before calling a service technician please check that... ... the operating instructions in the literature have been followed… SET TEMP Check that the filters are not dirty. If the air conditioner does not respond to the controls remove the plug from the electricity socket and then replace it again. ...the main switch is on, there are no breaks in the electrical cable and that the plug is correctly inserted in the socket... SET TEMP If the LCD displays “ ” the power supply is unstable: remove the plug from the electricity socket, wait 10 minuts and then replace it again. ” the water tank is If the LCD displays “ full: remove the plug from the electricity socket, drain out the water wait 3 minutes and then replace the plug again. Cleaning Hook OL PETR Hook Air inlet grille Periodically clean the air filters at the back of the unit, every 30 days or more often if necessary. Plug out the power supply before cleaning. To pull out the filters from their position press the two hooks of the grille to take off the card of air inlet grille, then take out the air filter. First clean the filters with a vacuum cleaner then rinse and dry the filters. Reinsert the filters correctly in their position. Clean the active carbon and silver plasma filter only with the vacuum cleaner instead of Water. To clean the appliance enclosure use only moist cloth and soap. NEVER use spray or flammable liquids. If the unit is not used for extended periods: Rear plate Rubber plug Drainage pipe Clamp Empty the remaining condensate water through the drain tube at the back of the indoor unit, then plug the tube and stow it. • Plug out the power supply. • Remove the residual condensation water through the small drain pipe situated at the rear of the indoor unit, then re-fit the plug and reposition the small pipe. • Clean the filters. • Rewind the electrical cable on the hook provided at the rear. • Hang the outdoor unit on the back of the indoor unit (split model). • Insert the two ends of the flexible pipe into their respective holes (stand-alone model). • Cover the air conditioner with a bag. GB - 9 Instruction to install drainage pipe accessories Parts included: Drainage pipe Clamp Pipe hoop Rubber plug Screw Installation Method: Caution: - To prevent drained water from staining the floor or carpet install the drainage pipe before starting the unit. - Keep the L-type rubber plug carefully taken from drainage hole to avoid loss. 1 . Take out the L-type rubber plug from drainage hole on the unit. 2 . Install the rubber plug in the drainage pipe. 3 . Fix the clamp on the rear plate with screws. 4 . Insert one end of the drainage pipe into the bottom of the drainage hole,and then install pipe hoop to prevent water leakage. L - type rubber plug 5 . Fix the drainage pipe in the clamp. Rear plate Drainage hole Clamp Rubber plug Clamp Drainage pipe GB - 10