Key Features, Phenolic Locker Series

Transcription

Key Features, Phenolic Locker Series
Phenolic Locker Series
P6000
Key Features, Phenolic Locker Series
• ½ inch doors and end panels
• Durable, backed by a 20 year warranty.
• Ideal choice for wet-use areas including pools and recreation centers
• Graffiti resistant, permanent marker is easily removed.
• Single-tier, multi-tier, and Z-style lockers available
• Lock options include Keyless Security, Zephyr, key, and padlock hasps
Page 1| PH6000
Hollman, Inc. | (972) 815-4000 | www.hollman.com
LOCK OPTIONS, PHENOLIC LOCKERS
Keyless1 is the newest Keyless lock. It includes a patented master key exchange system that
allows the master key to be updated without removing the lock. Users set their own personal
combination with each usage. It’s wireless, and uses no batteries.
Suggested Usage: Day-use
Because the combination can be easily reset with each usage, KSL locks are the best choice for dayuse lockers or environments where the locker users change frequently including fitness clubs, spas,
corporate, and activity centers.
Zephyr 3310 locks allow each user to enter their own self-selected combination using a pushbutton keypad. The lock clears the combination after each usage. No batteries are required.
Suggested Usage: Day-use
These locks are simple and reliable and are ideal for high volume, shared-use facilities.
Padlock Hasps allow users to bring their own padlocks, providing flexibility and minimal
management. ADA compliant padlocks are available for use with these systems as well.
Suggested Usage: Day-use or Permanent
These locks are versatile and can be used for most applications.
Key Locks can be keyed individually, alike, or in groups. A master key is provided.
Suggested Usage: Permanent
These locks are a great choice for single-user or team environments.
Built-In Combination Locks are provided with five different pre programmed three-digit
combinations.
Suggested Usage: Permanent
These locks are a good choice for assigned-use environments. There are no keys to lose and can be
accessed by a manager via a master key.
Page 2 | PH6000
Hollman, Inc. | (972) 815-4000 | www.hollman.com
PHENOLIC BENCH OPTIONS
Phenolic Benches, Top Options
Our Phenolic Benches are designed to coordinate with our lockers. Bench
tops are available in a range of lengths to meet your needs and are built from
the same durable, moisture-resistant phenolic material that we use for our
lockers. Bench tops are constructed from ¾ inch thick phenolic material.
Phenolic Benches, Design Options
The Pedestal Bench is the most common bench
utilized in a Locker room. Our bench legs are
made of 2” square x 1/8” wall
aluminum tubing with 6” square x 1/4” thick
flanges welded to the top and bottom, powder
coated flat black. The bench top is made of ¾”
thick phenolic with the corners
rounded and edges eased. The 9” or 12” depth
are our standard sizes available. The pedestals are
connected to the floor using stainless steel
fasteners.
Page 3 | PH6000
The Wall Mounted Bench is utilized in a Locker
room to conserve space. It is installed on a
studded or block wall in front of lockers. Our wall
mounted bench brackets are made from a single
piece of 1/8” aluminum with flanges formed for
mounting, powder coated flat black. The bench
top is made of ¾” thick phenolic with the corners
radius and edges eased. 12” depth is our standard
size. The wall brackets are connected to the wall
using stainless steel fasteners.
The ADA Pedestal Bench is utilized in a locker
room where physically disabled requirements
are necessary. Our bench legs are made of 1/8”
square tubing with ¼” flanges welded to
the top and bottom and powder coated flat black.
The bench top, back rest and support
brackets are made from ¾” thick phenolic with
the corners rounded and edges eased. The
connecting brackets that attach the parts
together are fabricated from 1/8” thick mill
finished aluminum. The pedestals are connected
to the floor using stainless steel
fasteners.
Hollman, Inc. | (972) 815-4000 | www.hollman.com
HOLLMAN PHENOLIC LOCKER SELECT COLOR OPTIONS
Hollman has carefully selected a collection of the industry’s most current FORMICA colors for our standard phenolic color set. A wide range of additional
options are also available.
949
3202
928
909
2013
845
800
914
756
7484
7583
5886
8830
7709
8846
6306
Page 4 | PH6000
Hollman, Inc. | (972) 815-4000 | www.hollman.com
ARCHITECTURAL SPECIFICATIONS, SECTION 10500 CLASS B FIRE RATED PHENOLIC LOCKERS
1.0GENERAL
1.1
SECTION INCLUDES
A. Phenolic Lockers.
B. Phenolic Athletic Lockers.
C. Phenolic Wardrobe Cabinets.
D. Phenolic School Cubbies.
E. Phenolic Locker Benches.
F. Bench Pedestals.
G. Locker Hardware and Accessories.
1.2 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract,
including General and Supplementary Conditions and
Division 1 Specification Sections, apply to this Section.
B. Wall backing and floor support to anchor Lockers
and Bench Pedestals.
1.3REFERENCES
A. American Society for Testing and Materials:
1.ASTM E84 Standard Test Method for Surface
Burning Characteristics of Building Material
2.ASTM D6578 Standard Practice for
Determination of Graffiti Resistance
3.ASTM D1037 Direct Screw Withdrawal Test
4.ASTM D570 Standard Test Method for Water
Absorption
5.ASTM A167, 18-8, Type 304 Cast Stainless Steel
B. National Fire Protection Association (NFPA).
C. UBC – Requirements for Handicapped.
D. ADA, Accessibility Guidelines for Buildings and
Facilities.
E. Southern Building Code.
F. 2005 LD-3 NEMA Standard Test, Chemical
Resistance, Modulus of Elasticity, Shear Strength and
Compression Strength.
1.4 QUALITY STANDARDS
A. Flame Spread: When tested in accordance
with ASTM E84, Lockers, Athletic Lockers, Wardrobe
Cabinets, School Cubbies and Locker Bench materials
shall meet or exceed all requirements for Class B
Flame Spread Rating and Smoke Developed and shall
carry a Class B Fire Rating Certification in accordance
with the requirements of NFPA and ICC. Class B Fire
Rating Certification shall be in the name of the Locker
Manufacturer and shall be less than six (6) months
old.
1. Flame Spread shall not exceed 75.
2. Smoke Developed shall not exceed 450.
B. Locker Doors: Locker Door shall be the full width
of the Locker Body and shall be frameless, allowing
access to the entire width of the Locker. Framed Doors
are unacceptable. Perimeter ventilation shall provide
superior ventilation properties to traditional framed
doors.
C. Locker Body: Locker Body shall incorporate the
Uni-Box® Locker Construction to allow for multiple
Locker configurations within the same Locker Body.
The Locker Body shall be white in color. The Uni-Box®
Page 5| PH6000
shall incorporate mortise and tenon construction and
shall be mechanically fastened with Stainless Steel
fasteners. Shelves shall be mortised into side walls of
the Uni-Box® and shall be secured with Stainless Steel
fasteners.
D. Graffiti Resistance Requirements: When tested
in accordance with ASTM D6578, Locker materials shall
prove resistant to all chemicals tested for a period
of 1 to 10 minutes and shall leave no mar or blemish
on the surface when cleaned. Locker materials shall
have guaranteed surface clean ability from permanent
markers and shall have Non-Ghosting properties.
E. Scratch Resistance Requirements: When tested
in accordance with ASTM D2197, Locker materials shall
prove to be scratch resistant when the maximum Load
Value exceeds 10 kilograms.
F. Impact Resistance Requirements: When tested in
accordance with ASTM D2794, Locker materials shall
withstand an Impact Force Value in excess of 45 inchlbs.
G. Screw Holding Strength: When tested
in accordance with ASTM D1037, Direct Screw
Withdrawal Test, Locker materials shall withstand a
direct pull force that exceeds 2,500 lbs per fastener.
H. Tensile Strength: Locker materials shall have a
Modulus of Elasticity of 1.55 Million PSI.
I. Shear Strength: Locker materials shall have a
Shear Strength of 2,000 PSI minimum.
J. Compression Strength: Locker materials shall
have a Compression Strength of 24,000 PSI minimum.
K. Water Absorption Requirements: When tested
in accordance with ASTM D570 Locker materials shall
have a Water Absorption Rate of less than 0.37%.
L. LEED® Contribution Requirements: Locker
materials shall contribute LEED® Certification credits
for New Construction, Existing Buildings and Schools.
MR 4.1, 4.2, 5.1 & 5.2, and EQ 4.
1.5SUBMITTALS
A. Product Data: Available upon request, including:
1.Preparation instructions and recommendations.
2.Storage and handling requirements and
recommendations.
3.Installation methods.
4.Product date specific to materials used in
construction of locker.
B. Shop Drawings: Indicate locker plan layout for
Hollman contracted installations, component profiles
and elevations, schedule of finishes, and accessories.
1.6 PRODUCT DELIVERY, STORAGE, AND HANDLING
A. Store products in a dry, ventilated area until ready
for installation.
B. Protect finishes from moisture, soiling and
damage during handling.
1.7 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature,
humidity, and ventilation) within limits recommended
by manufacturer for optimum results. Do not install
products under environmental conditions outside
manufacturer’s absolute limits.
B. During and after installation, maintain same
temperature and humidity conditions in building
spaces as will occur after occupancy.
C. Protect locker finish and adjacent surfaces from
damage.
1.8 Provide manufacturer’s Twenty (20) year written
limited warranty against breakage, corrosion,
delamination and defects in workmanship of all
Phenolic components; to be replaced without charge,
excluding labor.
2.0 PRODUCTS
2.1MANUFACTURERS
A. Series Numbers and Model Descriptions for Solid
Phenolic Lockers by Hollman, are listed below to
provide a standard of quality. Other manufacturers
may be submitted for evaluation by the architect.
All submittals for approval shall be presented
in accordance with the submittals clause of this
document and must be presented at least ten (10)
days prior to the bid date. All bids shall be based on
the standard of quality established herein.
B. Solid Phenolic Lockers, Athletic Lockers, Wardrobe
Cabinets, School Cubbies and Locker Benches shall be
Hollman Series PH6000
2.2MATERIALS
A. Material shall be Solid Phenolic with a High
Pressure Melamine matte finish surface made as
an integral part of the core material. Laminated
surfaces are not acceptable. Surface and edges
shall be non-porous and shall not support fungus or
bacteria. Provide material which has been selected
for uniform color, surface flatness and smoothness.
Exposed surfaces which exhibit discolorations, pitting,
seam marks, roller marks, stains, telegraphing of core
material, or other imperfections on finished units
are not acceptable. Defects such as chipping along
edges and corners are unacceptable. Columbia Solid
Phenolic shall meet or exceed all requirements for
Class B Flame Spread Rating and Smoke Developed
calculated according to ASTM E84, and shall carry a
Class B Fire Rating Certification. Class B Fire Rating
Certification shall be in the name of the Locker
Manufacturer and shall be less than six (6) months
old. Materials shall contribute to LEED® Certification
credits. MR 4.1, 4.2, 5.1 & 5.2, and EQ 4.
B. Material Thicknesses:
1.Doors, Slope Tops, End Panels, and Toe Kick
Plates – Minimum .50” (13 mm) Finished
Thickness.
2.Locker Uni-Box®, Tops, Bottoms, and Shelves
– Minimum .375” (10 mm) Finished Thickness.
Sides and Locker Backs – Minimum .3125” (8 mm)
Finished Thickness.
3.Locker Pedestal Benches – Minimum .75” (19
mm) Finished Thickness.
4.Locker Bench Tops – Minimum .75” (19 mm)
Finished Thickness.
Hollman, Inc. | (972) 815-4000 | www.hollman.com
ARCHITECTURAL SPECIFICATIONS, SECTION 10500 CLASS B FIRE RATED PHENOLIC LOCKERS
C. Colors: To be selected by Project Architect from
Manufacturer’s Standard Colors.
D. Locker Doors: Locker Door shall be the full
width of the Locker Uni-Box® and shall be frameless,
allowing access to the entire width of the Locker.
Framed Doors are unacceptable. Perimeter ventilation
shall provide superior ventilation properties to
traditional framed doors. Doors shall be attached to
the Hinge with Stainless Steel Theft Proof Torx Head
with Pin fasteners.
E. Locker Body: Locker Body shall incorporate the
Uni-Box® Locker Construction to allow for multiple
Locker configurations within the same Locker Body.
The Locker Body shall be white in color. The Uni-Box®
shall incorporate mortise and tenon construction and
shall be mechanically fastened together with Stainless
Steel fasteners. Locker Shelves shall be mortised
into side walls of the Uni-Box® at location determined
by Architect. Relocation of Shelves in the field shall
be possible without the need for special tools or
welders. The Hinge shall be attached to the Uni-Box®
with Stainless Steel Theft Proof Torx Head with Pin
Bolts. Lockers shall arrive at construction site fully
assembled.
F. Slope Tops, End Panels, and Toe Kick Plates: Shall
be manufactured of the same color, thickness and
material as the Locker Doors.
2.3HARDWARE
A. Locker Hinges: Hinges shall be concealed and
shall be made of 14 Gauge Type 304 Stainless Steel and
have a Satin finish. Hinge shall have five (5) knuckles
and shall allow door to open 90°.
B. Locker Hasp Bar: Hasp shall be fabricated of 11
Gauge Type 304 Stainless Steel with a Satin Finish. All
edges shall be polished and smooth. Hasp shall be
attached to the Locker Body with two (2) Stainless
Steel Theft Proof Torx Head with Pin, Through Bolts.
Hasp shall extend through a slot in the face of the
Locker Door and the Locker Number Plate. Locker
Hasp Bar is to be used with padlocks (padlocks are not
included).
C. Coat Hooks: Coat Hooks shall be fabricated of 11
Gauge Type 304 Stainless Steel with a Satin Finish. All
edges shall be polished and smooth. Coat Hooks shall
be attached to the Locker Body with Stainless Steel
Theft Proof Torx Head with Pin fasteners or Through
Bolts. Provide three (3) Coat Hooks for Single Tier
Lockers and three (3) for Double Tier and “Z” Lockers.
Plastic and aluminum Coat Hooks are unacceptable.
D. Number Plates: Provide a Number Plate for each
Door or opening, in the sequence as indicated on the
drawings. Number Plate shall be engraved from the
back side to prevent the accumulation of dirt and
grime.
E. Locker Legs: Provide Locker Legs for all Lockers
except recessed and base mounted Lockers. Locker
Leg assembly shall be structural and shall be fully
adjustable to provide for leveling and plumbing of
Locker Body. Provide Toe Kick Plates with all necessary
Page 6| PH6000
hardware for attaching to the Locker Leg.
F. Bench Pedestals: Provide all necessary Stainless
Steel fasteners to secure Bench Pedestal to the floor
and Bench Top. Select One (1) of the following:
1.Black Powder Coated Gauge Steel. Bench
Pedestal shall be constructed of 11 Gauge Steel
and shall be 16.5” High. Center post shall be
load bearing and shall extend from the floor to
the bottom of the Bench Top. Top and bottom
flanges shall be heli-arch welded to center post
and shall be 8” in diameter. Bench Pedestals shall
be secured to floor with Stainless Steel Torx Head
with Pin, #14 X 2” Screws.
2.Stainless Steel. Bench Pedestal shall be
constructed of 11 Gauge Type 304 Stainless Steel
and shall be 16.5” High. Center post shall be load
bearing and shall extend from the floor to the
bottom of the Bench Top. Top and bottom flanges shall be welded to center post and shall
be 8” in diameter. Bench Pedestals shall be
secured to floor with Stainless Steel Torx Head
with Pin, #14 X 2” Screws.
3.Black Powder Coated Aluminum: Bench
Pedestal shall be 16.5” High. Center post shall
extend from the floor to the bottom of the Bench
Top and shall be made of 2” square tubing. Top
and bottom plates shall be 6” square and shall be
.250” thick and shall be welded to 2” tubing.
Bench Pedestals shall be secured to floor with
Stainless Steel Torx Head with Pin, #14 X 2”
Screws.
4.Black Powder Coated Aluminum Wall Bracket.
Wall Bracket shall be made of .125” thick
Aluminum Plate and shall have a Black Powder
Coated Finish. Wall Bracket shall be mounted to
wall with two (2) #14 X 2” Stainless Steel Torx
Head with Pin, Screws. Each Wall Bracket shall be
capable of withstanding a sudden impact of 300
lbs.
G. Slope Top Mounting Channels and Supports:
Slope Top Mounting Channels and Supports shall be
made of Heavy Duty Extruded 6063-T5 Aluminum and
shall have a (Satin Anodized) (Black Anodized) finish.
Mounting Channels shall be field installed and shall
attach to the front top edge of the Locker Body and
shall be continuous across the front of the Lockers.
Supports shall be universal and shall attach to any
standard depth or width Locker via factory pre-drilled
holes.
3.0 EXECUTION
3.1EXAMINATION
A. Do not begin installation until adjacent substrates
and finishes have been properly prepared.
B. Verify prepared bases are in correct position and
configuration.
C. If preparation is the responsibility of another
installer, notify Architect of unsatisfactory preparation
before proceeding.
3.2PREPARATION
A. Clean surfaces thoroughly prior to installation.
B. Prepare surfaces using the methods
recommended by the manufacturer for achieving
the best result for the substrate under the project
conditions.
C. Verify adequacy of backing and support framing.
3.3INSTALLATION
A. Install in accordance with manufacturer’s
instructions.
B. If Hollman is not contracted for installation, client
must unload lockers from the delivery truck.
C. Set and secure lockers in place; rigid, plumb, and
level.
D. Use concealed joint fasteners to align and secure
adjoining cabinet units.
E. Conceal screw heads with plastic caps to match
locker interior.
F. Secure lockers with anchor devices to suit
substrate materials. Minimum Pullout Force: 100 lb
(445 N).
G. Install end panels, filler panels, tops and bases as
indicated on the approved shop drawings.
H. Install accessories.
3.4ADJUSTING
A. Adjust moving or operating parts to function
smoothly and correctly.
3.5CLEANING
A. Clean locker interiors and exterior surfaces.
3.6PROTECTION
A. Protect installed products until completion of
project.
B. Touch-up, repair or replace damaged products
before Substantial Completion.
Manufacturer reserves the right to change the
design or specifications to improve the product
or process at anytime, without notice.
2.4FABRICATION
A. General: Provide factory pre-assembled Locker
units. Lockers shall be complete with all hardware
and accessories listed above. Knock down units are
unacceptable.
B. Slope Tops and End Panels: Provide Slope
Tops and End Panels as required to complete the
installation of the Lockers.
Hollman, Inc. | (972) 815-4000 | www.hollman.com