inpond all-in-one with UVC 1400
Transcription
inpond all-in-one with UVC 1400
Blagdon Inpond with UVC AW v2.qxd Established over 40 years ago, Blagdon are committed to producing a comprehensive range of high quality, easy to use, pond equipment. An ongoing programme of research and development ensures excellent performance and value for all their customers. This product excellence is demonstrated by Blagdon’s award winning range of water gardening equipment. As a result Blagdon’s reputation for quality is unrivalled amongst experienced pond gardeners and retailers alike. Blagdon - The Pond Masters The name you can rely on Interpet, Vincent Lane, Dorking, Surrey, RH4 3YX Leaflet Code: BG Inpond 1-b 22/12/10 14:34 Page 1 inpond all-in-one with UVC 1400 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 3 CONTENTS Getting to know your Inpond Parts descriptions / spares codes - with exploded diagram inpond all-in-one with UVC 1400 Congratulations on buying a Blagdon All-in-One. Manufactured with advanced technology to create a clean and healthy pond for your fish. 2 2-4 Technical specifications 4 Pump performance / flow chart 4 Installation 5 Electrical installation Installing Inpond Installing UVC 5 6, 7 & 8 9 & 10 Maintenance and cleaning 11 Cleaning 11 Step by step guides 12 Routine maintenance 13 Annual maintenance 13 Winter storage 13 Troubleshooting Troubleshooting and maximise performance 16 16, 17 & 18 Faults - problem procedure 19 Consumer advice contact details 19 Returning faulty pumps 19 Guarantee 20 IMPORTANT Please attach proof of purchase to this manual and file in a safe place. 1 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 5 GETTING TO KNOW YOUR INPOND GETTING TO KNOW YOUR INPOND 30 29 31 28 27 25 8 36 26 27 7 38 6 BLACK 5 GREEN 37 4 33 23 3 36 22 21 2 24 32 20 43 19 35 9 18 11 42 10 1 34 2 12 41 13 14 15 16 40 39 17 No. Part Description Spare Code 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 35. 36. 37. 38. Filter body UVC Contact chamber Polymer wool pad Polymer wool cartridge Medium foam Coarse Foam Filter lid Locking handle Locking cap Double threaded attachment 11/2” Connecting pipe Pump locking nut 11/2” Impeller cover O ring Impeller complete Pump motor unit Pump back panel Light level sensor - Photo sensor Automatic LED Spot light O ring LED lamp LED lamp cover clear LED lamp screw cap Ball Joint 30cm Telescopic extension pipe 20cm extension pipe Control valve & diverter Fountain attachment Water bell large Daisy super Daisy Pump cable Low Voltage 10m Low voltage transformer + 3m 230v UVC electronics & cap Ceramic media Ceramic media Screw on hosetails 1/2” 12.5mm 1 /2” 12.5mm Silicone hose; not included 1 /2” 12.5mm Control valve hose attachment N/A N/A 1051166 N/A 1051170 1051170 N/A N/A N/A N/A N/A N/A N/A N/A 1017800 N/A N/A N/A 1051330 N/A N/A N/A N/A N/A N/A N/A N/A N/A 1017763 1017763 1017763 N/A 1017763 N/A N/A 1051187 N/A N/A N/A 3 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 7 INSTALLATION GETTING TO KNOW YOUR INPOND Electrical installation No. Part Description Spare Code 39. 40. 41. 42. 43. PL 5W UVC lamp Quartz sleeve UVC O ring 13m cable IPX7 Starter UVC + 10m of cable 1041041 N/A N/A N/A N/A The power supply must meet the specifications on the product. The pump is intended to be used with either a weather-proof cable connector or permanently connected to the fixed wiring in the main system other than by means of a plug and socket. The cores in the supply cable are coloured in accordance with the following code: Brown = Live, Blue = Neutral, Green/Yellow = Earth. Pump performance / flow chart The electric cable is permanently connected and sealed in the motor body. If the supply cable is damaged the pump must not be used. Tech Specification: Cable Fitted 13 metres Voltage 12V Pump Watts 10 700ltr (154 gal) Safety Rating IP68 1.25m max head (4.1”) Maximum Depth _ 1.25 metres CC 12v Low voltage Maximum Lift 1.25 metres / 4’1” IP56 Weatherproof transformer Do not use the supply cable to lift the pump as this may cause damage. WARNING - THIS PUMP MUST BE EARTHED 10m of low voltage cable 10w IP68 Lift Flow rates lph 2.0 metres - 1.5 metres - 1.0 metres 300 lph 0.5 metres 520 lph 0.0 metres 700 lph Flow is given as optimum rate A Residual Current Device (RCD), also know as the Residual Current Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the supply circuit. A means of disconnection from the supply having a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring. LED For permanent installations to the mains supply, it is necessary to conform to the regulations of the local electricity authority and this would include the use of a metal or plastic conduit to protect the cable. Photo sensor activated 0.76w UVC Attention has been drawn to the fact that special rules may exist concerning the installation of your pond pump (i.e. local building regulations). 5w PL lamp 13m of cable These pumps must not be used in swimming pools, or areas where people are in contact with the water. 230v 50Hz IP68 Always disconnect the mains electricity supply whilst the equipment is being installed, repaired, maintained or handled. Consult a qualified electrician if in any doubt about wiring this product to the main supply. Specification chart Warning - The Inpond pump is provided with a thermal cut out that temporarily switches off the pump in case of overheating and the pump may automatically restart. 1400 4 1400ltr/307.95gal 700ltr/153.97gal 700ltr/153.97gal 525ltr/116gal 262ltr 58gal 18W 25mm/1” 5 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 9 INSTALLATION Locating your Inpond All-in-One The Inpond pump and filter should be located on a firm and level base in the pond/water feature in a depth of at least 10cm, but no more than 1.25m. It is advisable to keep the pump off the bottom of the pond to avoid silt entering the pump causing excessive wear and increasing pre-filter cleaning. Fountain INSTALLATION CONVENIENT INSTALLATION The Inpond All-in-One can be installed either powering a waterfall or fountain. Waterfall or feature option WATERFALL OR FEATURE Make sure there is ample cable from mains supply. Place filter in desired location. Add Fountain extension pipes so fountain head is above surface of the pond. Fountain height can now be adjusted, see ‘Adjusting flow control’ diagram below. See "Getting to know your Inpond" for parts and descriptions. FOUNTAIN MAX 70cm HOSE Inpond Filter ADJUSTING FLOW CONTROL Turn clockwise to increase anti-clockwise to reduce flow. Fountain option BELL FOUNTAIN Adjust bell by moving head higher for small bell and lower for a wider bell shape. MIN 40cm Inpond Filter TYPICAL INSTALLATION The flow control valve is fitted with a diverter to ensure there is always pond circulation. Tip: Ensure that any fountain or feature fitted does not empty water out of pond/water feature. Water Feature Install as for Fountain. Depending on water feature to be supplied, your Inpond All-in-One can be used with the flow control and the 1/2" hose fitting. Hose clips should be used to secure hose. See page 8, fitting a waterfall or feature. 6 7 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 11 INSTALLATION MAINTENANCE & CLEANING WATERFALL INSTALLATION IMPORTANT - Failure to carry out routine maintenance leaving the pump under reduced or no flow conditions for long periods will result in a shorter pump life and will invalidate the guarantee. IMPORTANT The outlet hose should be smooth bore (not corrugated) pipe installed over as short a distance as possible with no kinks or bends. We recommend that Blagdon smooth bore clear hose or Blagdon heavy duty smooth bore black hose are used. INSTALLING THE WATERFALL OR FEATURE CONNECTING OUTLET HOSES Routine Maintenance Carry out routine maintenance when flow is visibly reduced. Waterfall or Feature 12.5mm / 1 /2” The Blagdon Inpond All-in-One pump is centrifugal with a magnetic impeller movement driven by a watertight synchronous motor. They require minimum cleaning, only periodic cleaning of the impeller is necessary. 1. Switch off electricity. 2. Remove filter from pond (do not use the cable to lift the pump.) Recommended HOW IT WORKS - FLOW DETAIL The recommended hose size for your Inpond filter is stated in the filter performance and specification chart. 36 27 Flow control Inlet grills Coarse foam Automatic LED spot light Photo Sensor Always secure hose with a jubilee clip. 38 Warming the hose in a bucket of boiling water can aid fitting. Always ensure that the smaller diameter hosetail is cut off and removed to prevent reduced filter performance. Use the shortest possible hose lengths to minimise flow restrictions. Avoid folds and kinks in the hose, which will reduce flow and filter performance. 8 Low voltage Pump Locking handle 37 24 Medium foam Polymer wool pad cartridge 36 21 UVC contact chamber Inlets Ceramic biomedia 16 9 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 13 MAINTENANCE & CLEANING Opening and locking filter handle Easy lift integrated locking handle Locked Note the handle is in the locked position UVC INSTALLATION UVC LAMPS & QUARTZ SLEEVE MAINTENANCE The UVC lamp must be replaced every six months / once a season. It is recommended that the lamp is replaced and reconnected in the spring. The Quartz sleeve can become coated in lime scale build up in hard water areas. This should be carefully removed from the quartz sleeve and cleaned with a soft cloth. A wet test must be carried out after maintenance to ensure there are no leaks before the UVC is reconnected. Locked WET TESTING THE UVC Handle is in the central position. This will enable the filter and pump to be carried in and out of the pond. * Ensure the filter is not carried by the pump cable. Unlocked The handle is in the unlocked position allowing the filter media to be removed and cleaned. Foams may be cleaned vigorously in a bucket of pond water. Adding Blagdon Bio Start after filter maintenance will help replenish these beneficial bacterial populations and is highly recommended during the first two months of operation when the filter is slowly being colonised. Ceramic bio media These will only need very occasional cleaning (once per year), but must be rinsed in pond water to prevent damaging the beneficial bacteria which help maintain a healthy pond. 10 IMPORTANT: A wet test of the UVC under operating conditions must be carried out before the UVC or electrical supply is installed. Connect the UVC to the Inpond following all installation instructions. After running for 24 hours check for leaks. TESTING/REPLACING THE UVC LAMP IMPORTANT: Ensure that the mains supply is switched off and the power isolated before removing the UVC cover. 1. Unscrew the UVC electronics cover cap. 2. Inspect the UVC cap and Quartz sleeve for water leaks. 3. If there are no signs of leakage reverse the procedure ensuring that the Cover O-ring is in place. 4. This unit is protected by a micro switch that prevents the UVC light from illuminating when the cover is removed even if the power is on. 5. In order to check that the UVC lamp is operating see page 19 section 2 on how to view you UVC lamp. 11 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 15 UVC ELECTRICAL INSTALLATION UVC ELECTRICAL INSTALLATION WARNING - A Residual Current Device (RCD), also known as the Residual Current Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the supply circuit. A means of disconnection from the supply having a contact separation of at least 3mm in all poles must be incorporated in the wiring. 3 4 2 1 5 IMPORTANT: Please note all electrical work on garden lighting and power installations must comply with part P of the building regulations. Failure to comply is a criminal offence. If the installation of this product is not carried out by a competent electrician who is registered under the Part P selfcertification scheme then you must notify the local building control department before work begins. For further information and guidance on this matter and other electrical installations in your home that might be covered by the relevant legislation, contact your local authorities building control department. For permanent installations to the mains supply, it is necessary to conform to the regulations of the local electricity authority and this would include the use of a metal or plastic conduit to protect the cable. If there has been any damage to the unit please return to the point of purchase for inspection. Attention has been drawn to the fact that special rules may exist concerning the installation of your pond UVC (i.e. local building regulations). This test should be repeated whenever the the bulb or quartz is changed. This UVC must not be used in swimming pools, or areas where people are in contact with the water. Warning: Direct exposure to UVC light can damage your eyes or skin. Electrical installation - UVC Always disconnect the mains electricity supply whilst the equipment is being installed, repaired, maintained or handled. Consult a qualified electrician if in any doubt about wiring this product to the mains supply. The power supply must meet the specifications on the product. The cores in the supply cable are coloured in accordance with the following code: Brown = Live, Blue = Neutral. Do not use the supply cable to lift the UVC as this may cause damage. 12 Electrical Safety UVC warning: Dangerous Ultra Violet radiation. The rays from the UVC lamp are harmful to eyes and skin. Always turn off UVC electrical supply before any maintenance. To protect the UVC starter; never immerse in water. Locate the UVC starter (part 43) 1m minimum from pond edge. 13 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 17 MAINTENANCE & CLEANING MAINTENANCE & CLEANING LED Automatic Photo Sensor Polymer wool cartridge /2“ hose fitting 1 The polymer wool pad may be washed a limited number of times before it starts to lose efficiency and blocks rapidly. Replacement packs of polymer wool are available from your retailer and are quick and easy to replace. See page 10 on how to remove the cartridge easily from the Inpond. Active hinge Automatic LED spot light Ball joint LED automatic sensor Pump If the LED light is not required you can permanently remove the lamp (see removing lamp section page 14). - detects when light levels are low/dusk The LED automatic sensor is positioned on top of the motor body between the outlet and the lamp. Ensure this is kept clean from dirt and algae as it needs sufficient light to activate correctly. This extremely efficient lamp uses less than 1 watt of electricity which automatically turns on at dusk and off at dawn. Polymer wool cartridge Annual maintenance of the filter Check for wear. Once a year you should dismantle your Inpond. Dismantle the filter examining all the parts for wear or damage, replacing any parts showing obvious signs of wear and/or damage (see getting to know your filter for replacement codes and parts descriptions on page 2 & 3). Polymer wool pad 23 Annual maintenance of the pump Once a year you should service your pump. Dismantle pump and examine all parts for wear or damage, replacing any parts that show obvious wear and/or damage (see getting to know your Inpond for parts/description and replacement parts codes). Particular care should be taken to examine the cable entry points. Removing LED Lamp 22 Replacing or removing the lamp can be easily done by unscrewing part 23 from the lamp holder (part 19) then part 22 will be able to be removed. Allowing the lamp to be disconnected (part 21). 20 Annual maintenance of the UVC 19 Check for wear. Once a year you should dismantle your Inpond UVC section. Dismantle the UVC containing all the parts for wear and damage, replacing any parts that show obvious signs of wear or damage (see getting to know your Inpond filter for replacement codes and parts descriptions on pages 2 & 3). 21 Pump IMPORTANT - Ensure that the mains supply is switched off and the power isolated before removing the lamp cover. 14 Winter Storage The Inpond filter and pump can be run in the pond during the winter but care should be taken to ensure that it is fully immersed and cannot freeze solid. If the pump is not used during the winter follow the annual maintenance procedure and store frost-free in the house or garage until spring. 15 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 19 TROUBLESHOOTING Inpond Filter Filter leaks TROUBLESHOOTING Inpond Pump Problem • Check that the filter outlet nut and O ring have been correctly assembled and that they are hand tight. Low flow from pump • PTFE tape may be needed to give a water tight seal and should be applied to outlet hosetails. 2. Follow monthly cleaning procedure. • Always secure the filter outlet hose with a jubilee clip. 1. Follow routine cleaning procedure if no improvement. 3. Ensure pipe work is not blocked, leaking or is laid so that it gets crushed or kinked. Cloudy/brown water 4. Keep the height that water is to be pumped from the water surface (called Head) to a minimum. The higher the head the lower the flow rate and the more wear on the pump. • The flow rate / pond turnover is to high or to low. Check that you have correctly calculated the pond volume and that pump flow rate is within limits. 5. Use the largest diameter, smoothest bore pond hose over the shortest distance and keep hose fittings to a minimum. This removes frictional loss of flow and so increases pump flow rates. • Insure that the filter is installed on a flat and level base. • The filter is not being supplied with water 24 hours a day. Do not turn off your pump. Continuous running is needed to maintain a clean and healthy pond. • The filter foam pads are insufficiently blocked to trap the fine waste. Treat with Blagdon Clear Pond treatment. • The water is extremely dirty, remove pond waste and leaves - carry out a partial water change. • Filter is incorrectly sized - refer to filter performance and specification chart. • The filter foams have not been positioned or replaced correctly,ensure that the foams fit tightly within the filter chamber. UVC leaks • Check that the UVC O-ring have been correctly assembled and that it is hand tight. • PTFE tape may be needed to give a water tight seal and should be applied to the outlet hosetail. 16 Poor Fountain performance • Reduced height. DAISY • Jets blocked. To clean, remove head and rinse. Or in hard water areas, use Pond Pump Cleaner. Clean flow adjuster and fountain head. Wash under a tap or hose. ond Pump Cleaner should be used to remove lime scale build-up/waste (see diagram) for improved results. No flow from pump 1. Check power supply is on. 2. Check fuse and wiring (SEE ELECTRICAL INSTALLATION). 3. Follow low flow procedure as above. If none of the above works contact Interpet (Blagdon) Consumer Advice Department (See Faults problem procedure Page 20). 17 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 21 TROUBLESHOOTING IMPORTANT Green water FAULTS - PROBLEMS PROCEDURE • Settlement test the water to ensure that there is no sediment suspended in the water. If there is, follow the brown cloudy water troubleshooting guide. Before returning your Inpond to your dealer or contacting our Consumer Advice Department, please carry out the following steps. This will solve most problems quickly and easily. • In order to check that the UVC lamp is operating: Open the filter unit (see page 10) remove filter foams and cartridge. Then using a white piece of card against the UVC contact chamber inlet you should see a faint blue light. This operation may need to be carried out at dusk as UVC lamps emit a dim blue light under normal operation. Turning the lamp on and off may aid visual identification. (Ensure the UVC lamp is not more than 6 months old). • The UVC may be working effectively but the filter foam/media is too clean and is unable to remove the fine coagulated waste. Treat the pond with Clear Pond and do not clean the foams/media until they are blocked. • The filter is too small for the pond, check your filter selection chart. • The UVC quartz sleeve is dirty or coated in lime scale. Gently remove the quartz sleeve and clean. 1. Ensure electrical procedures have been followed fully. Check fuses and any cable connectors/switch boxes. 2. (a) Follow routine maintenance procedure fully. (b) Check location and connecting your pump details including flow rates. (c) Ensure that your pond volume and pump flow rate meet the maximum pond size recommended for the filter model on the filter performance and specification chart. (d) Follow troubleshooting guide. 3. If there is a mechanical breakdown of the filter or UVC, return to the point of purchase for inspection and advice (You will need proof of purchase). CLEARWATER GUARANTEE The Clearwater guarantee will be honoured for 1 year after proof of purchase. Clearwater is guaranteed to a depth of 1m, so that fish are clearly visible. Clearwater is guaranteed provided: • You follow all instructions as above. • Your filter is within the performance guidelines stated. UVC light not illuminated • You consult the Consumer Advice Line and follow any advice to correct the situation. See details below. • Check all fuses / RCD and electrical connections follow electrical installation (pages 11 & 12). Refunds can only be authorised by Interpet Blagdon. • Follow all cloudy water trouble shooting points. CONSUMER ADVICE CONTACT DETAILS Interpet (Blagdon) Consumer Advice Department Vincent Lane, Dorking, Surrey RH4 3YX Telephone: 0845 226 7437 (Monday to Friday 10am to 4pm except Bank Holidays - Times may vary) Fax: 01306 876712 E-mail: customercare@interpet.co.uk www.blagdonthepondmasters.co.uk 18 19 Blagdon Inpond with UVC AW v2.qxd 22/12/10 14:34 Page 23 GUARANTEE This product is guaranteed against defects in material and workmanship for 2 years from the date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper use, negligence, lack of maintenance or accidental damage to either the filter or UVC. If the filter or UVC fails due to a manufacturing fault within this period it will be either repaired or replaced free of charge. Liability is limited to replacement of the faulty product only; no other costs will be reimbursed. This guarantee is not transferable and does not affect your statutory rights. This guarantee does not confer any rights other than those expressly set out above. This guarantee does not cover the filter foams or UVC bulb, which will need replacing when worn or every 6 months. If any parts are needed, spares are available from your retailer. You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical equipments to an appropriate waste disposal centre. 20
Similar documents
inpond all-in-one with uvc 1400/3000
Parts Descriptions / spares codes - with exploded diagram Getting to know your Inpond 3000
More information