Ferroli Cast Iron Boiler Range
Transcription
Ferroli Cast Iron Boiler Range
Ferroli Cast Iron Boiler Range Industrial & Commercial Heating Systems. w w w. p ow r m a t i c. co. u k H E AT I N G // V E N T I L AT I O N // AIR CONDITIONING Atlas A Floor Standing Boiler 3 pass-flue floor standing boiler, only heating, for oil or gas jet burner. Features and Benefits New compact design High efficiency cast iron boiler body Silent operation thanks to low flues turbulence Widely copes with requirements for 2 stars efficiency according to directive 92/42 EEC New analogue control panel with smart fume cover Control board includes thermometer and pressure gauge, ignition switch, safety thermostat with manual reset and temperature setting knob Optional range of one and two stage* burners to be easily fitted, both for gas or liquid fuel * Two stage only available on Atlas A 95 2 year* parts & labour Guarantee Equipped with a user-friendly, control panel. 18 2 Technical specifications Atlas A 32 47 62 78 95 Max thermal output kW 32 47 62 78 95 Max thermal capacity kW 34.9 51.6 67.7 85.6 103 Water content litres 18 23 28 33 38 Efficiency Pmax (80°– 60°C) % 91.7 91.1 91.5 91.1 92 Max. heating operating pressure bar 6 6 6 6 6 Dimensions D mm 400 500 600 732 832 B Ø mm 115 115 115 115 115 F Ø mm 120-130 120-130 120-130 120-130 120-130 127 166 205 244 283 3 4 5 6 7 X0D X0D X0D X0D X0D Empty weight kg Number of sections IP protection rate IP 500 D 1 F 850 B 3 2 105 145 145 105 KEY 1 system delivery Ø 11/2" 2 system return Ø 11/2" 3 heating system drain cock 1/2" 19 3 GN2 Gas, oil or dual fuel, cast iron, free-standing boilers High efficiency heat generators for the production of hot water for central heating installations serving medium to large residential or industrial premises. The GN range of boilers is available for pressure jet oil, forced air gas or dual fuel with a range of burners for ON/OFF or high/low operation. Features and Benefits Ferroli boilers are manufactured from high quality cast iron and are designed for a reliable long life – with a 10-year manufacturer’s material guarantee on the cast iron work All GN models are suitable for natural gas, LPG or oil-fired pressure jet burners, with a dual fuel option The GN range is a highly efficient boiler with on/off, high/low or modulating burner operation We can also supply pre-mix burners which are fully modulating, low NOX and quiet High efficiency, reduce fuel consumption Boiler body is insulated with high density mineral fibre to minimise heat loss from the heat exchanger GN2 models have a double-pass heat exchanger Designed for use with fully pumped indirect systems operating at working pressures up to 6 bar at 90ºC flow temperature 2 year* parts & labour The pre-wired control panel is housed in a stylish casing and incorporates: on/off illuminated Guarantee switches; high/low thermostatic control with limit thermostat (manual re-set); and a temperature and pressure gauge Front access for ease of maintenance and minimum side clearance required Suitable for modular installations 20 4 Technical specifications Number of sections Delivered heat output Heat input 05 06 07 08 09 10 11 12 13 14 max. kW 90 108 126 144 162 180 198 216 234 252 min. kW 73 87 101 115 129 143 157 171 185 199 max. kW 98.8 117.4 136.9 156.5 176.0 195.6 215.2 234.7 254.3 273.9 min. kW 80 95 110 125 140 155 170 185 200 215 litres 49 57 65 73 81 89 97 105 113 121 litres/sec 1.95 2.35 2.74 3.13 3.52 3.91 4.3 4.7 5.01 5.47 mb 2.8 3.4 4.8 6.5 8.5 11 13 16 19 23 litres/sec 1.07 1.29 1.5 1.72 1.93 2.15 2.36 2.58 2.79 3.00 Water content Design flow rate @ Δt 11ºC Water pressure loss @ Δt 11ºC Design flow rate @ Δt 20ºC Water pressure loss @ Δt 20ºC mb – – 0.5 0.8 1.8 2.2 2.6 3.2 4.0 4.5 Water pressure max bar 6 6 6 6 6 6 6 6 6 6 m 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 litres/sec 0.72 0.86 1.0 1.15 1.29 1.43 1.58 1.72 1.86 2.0 m3/h 10.46 12.28 14.49 16.56 18.62 20.70 22.77 24.84 26.91 28.98 Static head min Flow rate min Input gas rate max Working pressure boiler gas mb 20 20 20 20 20 20 20 20 20 20 Max gas inlet gas pressure mb 25 25 25 25 25 25 25 25 25 25 Draught required @ boiler flue outlet mb 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 2 2 2 2 2 2 2 2 2 2 Pascal Burner pressure as Burner manufacturers data Flue gas volume @ NTP m 3 140 159 196 218 247 273 305 326 370 402 Flue gas temperature ºC 220 220 220 220 220 220 220 220 220 220 mb 0.3 0.31 0.32 0.33 0.34 0.36 0.37 0.38 0.39 0.40 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 Boiler flue gas resistance Electric supply 230v 50Hz Combustion chamber Δp mbar Combustion chamber volume litres 63 77 91 104 118 132 146 160 174 187 Dimensions Height mm 1196 1196 1196 1196 1196 1196 1196 1196 1196 1196 Width mm 600 600 600 600 600 600 600 600 600 600 Depth mm 647 757 867 977 1087 1197 1307 1417 1527 1637 Blast tube diameter mm 130 130 130 154 154 154 154 154 154 154 Flue diameter mm 180 180 180 200 200 200 200 200 200 200 Fittings Water flow/return DN80 3 3 3 3 3 3 3 3 3 3 Drain cock inches 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Gas inlet connection Weight Clearance as Burner manufacturers data kg 310 361 412 463 514 565 616 670 725 780 Front (min) mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Rear (min) mm 800 800 800 800 800 800 800 800 800 800 Side (min) mm 200 200 200 200 200 200 200 200 200 200 21 5 GN4 Gas, oil or dual fuel, cast iron free-standing boilers High efficiency heat generators for the production of hot water for central heating installations serving medium to large residential or industrial premises. The GN range of boilers is available for pressure jet oil, forced air gas or dual fuel with a range of burners for ON/OFF or high/low operation. Features and Benefits Ferroli boilers are manufactured from high quality cast iron and are designed for a reliable long life – with a 10-year manufacturer’s material guarantee on the cast iron work All GN models are suitable for natural gas, LPG or oil-fired pressure jet burners, with a dual fuel option The GN range is a highly efficient boiler with on/off, high/low or modulating burner operation We can also supply pre-mix burners which are fully modulating, low NOX and quiet High efficiency, reduce fuel consumption Boiler body is insulated with high density mineral fibre to minimise heat loss from the heat exchanger GN4 has a triple-pass heat exchanger for maximum heat transfer and ultra-high operating efficiency Designed for use with fully pumped indirect systems operating at working pressures up to 6 bar at 90ºC flow temperature 2 year* parts & labour The pre-wired control panel is housed in a stylish casing and incorporates: on/off illuminated Guarantee switches; high/low thermostatic control with limit thermostat (manual re-set); and a temperature and pressure gauge Front access for ease of maintenance and minimum side clearance required Suitable for modular installations 22 6 Technical specifications Number of sections Delivered heat output Heat input 07 08 09 10 11 12 13 14 max. kW 200 250 300 360 420 480 560 650 min. kW 120 150 180 215 250 290 330 390 max. kW 217 270 324 388 452 516 600 695 min. kW 128 160 192 229 266 309 352 416 litres 143 163 183 203 223 243 263 283 litres/sec 4.32 5.39 6.46 7.75 9.08 10.4 12.1 14.1 66 99 139 178 215 254 292 331 2.58 2.7 3.3 3.87 4.53 5.17 6.03 7.0 Water content Design flow rate @ Δt 11ºC Water pressure loss @ Δt 11ºC mb Design flow rate @ Δt 20ºC litres/sec Water pressure loss @ Δt 20ºC mb 20 30 42 54 65 77 88 100 Water pressure max bar 6 6 6 6 6 6 6 6 m 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 litres/sec 1.73 2.16 2.6 3.6 3.12 1.16 4.85 5.63 m3/h 20.28 25.23 30.28 36.26 42.24 48.22 56.07 64.95 Static head min Flow rate min Input gas rate max Working pressure boiler gas mb 20 20 20 20 20 20 20 20 Max gas inlet gas pressure mb 25 25 25 25 25 25 25 25 as Burner manufacturers data Burner pressure Flue gas volume @ NTP m 3 318 393 468 558 646 734 848 977 Flue gas temperature ºC 200 200 200 200 200 200 200 200 mb 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 2 2 2 2 2 2 2 2 Yes Yes Yes Yes Yes Yes Yes Yes Length mm 880 1010 1140 1270 1400 1530 1660 1790 Ø mm 500 500 500 500 500 500 500 500 Draught required @ boiler flue outlet Pascal Electric supply 230v 50Hz Combustion chamber Combustion chamber volume litres 161.3 185.1 208.9 232.8 256.6 280.4 304.3 328.1 Dimensions Height mm 1193 1193 1193 1193 1193 1193 1193 1193 Width mm 850 850 850 850 850 850 850 850 Depth mm 1040 1170 1300 1430 1560 1690 1820 1950 Flue diameter mm 180 180 250 250 250 250 250 250 Fittings Water flow/return DN80 3 3 3 3 3 3 3 3 Drain cock inches 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" as Burner manufacturers data Gas inlet connection Weight Clearance kg 940 1050 1170 1270 1400 1510 1630 1740 Front (min) mm 1000 1000 1000 1000 1000 1000 1000 1000 Rear (min) mm 800 800 800 800 800 800 800 800 Side (min) mm 200 200 200 200 200 200 200 200 23 7 Econcept 51A – Wall mounted Wall mounted modulating condensing boiler for heating with premix burner with very low emissions Modular, premix, condensing heat generators, with very high efficiency and very low polluting emission, operating on natural gas or LPG. These generators have been designed to be installed in modular configurations, (up to five) to extend the benefits of high-efficiency heating to larger applications. Features and Benefits Modulating high efficiency premix condensing boiler for heating installations Modular installation without the need of additional controllers Microprocessor controls Independent external switching of controls to maximise efficiency Hot surface ignition with independent flame detection probe Low water pressure protection switch Independent internal 6 bar safety valve 2 year* Can be used on pressurised systems or open vented systems where min. 1 bar is available parts & labour Guarantee Modular boiler control – The Econcept 51A is ready for modular application. The heat output of the various modules can be optimised according to the heating load of the system 4 8 Technical specifications Econcept 51A Heat input in central heating operation max. kW 49.8 min. kW 11.2 Heat output in central heating max. kW 48.8 operation (80-60°C) min. kW 11.0 Heat output in central heating max. kW 53.0 operation (50-30°C) min. kW 12.0 Operating pressure max. bar 6.0 min. bar 0.8 Height mm 720 Width mm 630 Depth mm 380 Ø 3/4" All connections Water circuit content Max outlet temperature Index of protection l 10 °C 95.0 IP X5D V/Hz 230/50 Power input W 190 Empty weight kg 124.0 Power supply voltage Type of appliance B23 Efficiency Efficiency (80-60°C) Pmax Efficiency (50-30°C) Efficiency 30% (30°C) % 98.0 Pmin % 98.5 Pmax % 106.4 Pmin % 107.5 % 109.0 NOx class 5 PUMP ACCESSORY KIT (Code 042034X0) For the advanced management of an external hot water cylinder the boiler can be fitted with a special kit which allows the pump for the hot water cylinder and the return connection to be housed directly in the boiler. The electronic board manages priority of the hot water cylinder, switched by the cylinder’s control stat. When the cylinder is satisfied the boiler automatically returns to heating mode. TRAVERSE FLAME CERAMIC BURNERS The ECONCEPT 51A modules feature premix ceramic burners with reverse micro-flame, each made up of six plates fastened via a special gasket to a metal frame capable of absorbing thermal expansion. These burners have very low polluting emissions, both NOx and CO2. HEAT EXCHANGERS The heat exchangers design, build and materials ensure high efficiency, constant performances reliability. CASCADING OPERATION The ECONCEPT 51A series modules have been developed for connection in series to make up a single heat generator that, in steps of 50kW, can have a total output up to 250kW. Each with electronic programming to ensure the optimum operation from 11kW to 250kW. Control board Each ECONCEPT 51A is fitted with a user friendly multi-function display panel, which controls all basic operations. It will control up to five combustion units and handles the central heating pump plus a second pump or diverting selector valve for the hot water storage cylinder. 5 9 Energy Top – Wall mounted Wall mounted heat generators featuring a premix burner, condensing operation, very high efficiency and very low polluting emissions. Suitable for heating only systems, featuring high energy savings and are environmentally-friendly (4 star energy rating). Cascading connection of multiple generators can be performed using special flue gas and water circuit accessories. The models are configured for operation on natural gas but can be converted to LPG using a special conversion kit. Features and Benefits Modulating high efficiency premix condensing boiler for heating installations Modular installation without the need of additional controllers Microprocessor controls Independent external switching of controls to maximise efficiency Hot surface ignition with independent flame detection probe Low water pressure protection switch Independent internal 6 bar safety valve Can be used on pressurised systems or open vented systems where min. 1 bar is available Modular boiler control – The Energy Top W is ready for modular application. The heat output 2 year * of the various modules can be optimised according to the heating load of the system parts & labour Guarantee Unique spiral corrugated heat exchanger 6 10 Technical specifications W80 W125 Output and Efficiency Heat input, central heating Heat output, central heating Efficiency max. kW 75.0 116.0 min. kW 17.0 25.0 max. (80 - 60°C) kW 73.5 113.7 min. (80 - 60°C) kW 16.7 24.6 max. (50 - 30°C) kW 79.5 123.0 min. (50 - 30°C) kW 18.3 26.9 Pmax (80 - 60°C) % 98.0 98.0 Pmin (80 - 60°C) % 98.5 98.5 Pmax (50 - 30°C) 106.0 106.0 % Pmin (50 - 30°C) % 107.5 107.5 30% (30°C) % 109.0 109.0 ★★★★ ★★★★ 5 5 Efficiency class Directive 92/42 EEC NOx class Central heating operating pressure max-min. bar 6-0.8 6-0.8 Central heating temperature max. °C 95 95 °C 40 40 litres 5 7 IP X5D X5D V/Hz 230/50 230/50 W 95 200 Weight kg 46 51 Height mm 900 900 Width mm 445 445 Depth mm 430 430 Outlet/return fittings inches 11/2" 11/2" Gas fitting inches 1" 1" % 2.2-1.3 1.8-1.3 Losses through the casing with burner ON at Pmax-Pmin % 0.2-0.2 0.2-0.2 Losses through the stack with burner OFF % 0.03 0.02 Losses through the casing with burner OFF % 0.4 0.4 Flue gas temperature at Pmax-Pmin °C 65-60 67-60 Max exchanger Δt Water content Electrical specifications Index of protection Power supply voltage Power input (not including the pump) max. Structural characteristics FURNACE The new total premixed air-gas combustion unit with variable speed fan, pneumatic gas valve and cylindrical metal fibre burner allows a range of modulation that, depending on the model, can extend from 11 to 100% of rated output, with efficiency exceeding 107%. The very low emissions – NOx and CO2 – as well as minimising the environmental impact, also ensures the heat exchanger remains clean over time, reducing maintenance. ELECTRONIC CONTROL The evolved electronics on ENERGY TOP can manage situations in which multiple heat generators are used in cascade, minimising the configuration and commissioning operations. CASCADING OPERATION Multiple generators can be linked. The models are factory configured for operation on natural gas and can be converted to LPG using a special conversion kit. Water circuit Combustion data Losses through the stack with burner ON at Pmax-Pmin (80/60) °C 43-33 45-34 Flue gas flow-rate at Pmax-Pmin (50/30) kg/h 126.2-30.1 195.2-44.3 Condensate flow-rate at Pmax-Pmin kg/h 8.7-2.0 13.5-3.2 % 9.0-8.5 9.0-8.5 CO2 at Pmax-Pmin (G20) CO2 at Pmax-Pmin (G31) % 10-9.2 10-9.2 CO weighted mg/kWh 35.0 35.0 NOx weighted mg/kWh 29.0 29.0 7 11 Econcept 101– Floor standing Floor standing, modulating condensing boiler for heating with dual heat exchanger and double premix burner with very low emissions Modular, premix, condensing heat generators, with very high efficiency and very low polluting emission, operating on natural gas or LPG. These generators have been designed to be installed in modular configurations, (up to five) to extend the benefits of high-efficiency heating to larger applications. Features and Benefits Modulating high efficiency premix condensing boiler for heating installations Vertical modular structure with built-in manifold pipework Dual heat exchangers with independent microprocessor controls Independent external switching of controls to maximise efficiency Hot surface ignition with independent flame detection probe Low water pressure protection switch Independent internal 6 bar safety valves 2 year* Boiler manifold can be bolted directly together; minimises use of space and installation time parts & labour Guarantee Can be used on pressurised systems or open vented systems where min. 1 bar is available Modular boiler control – The Econcept 101 is ready for modular application. The heat output of the various modules can be optimised according to the heating load of the system 8 12 Technical specifications Econcept 101 Output max/min. Heat input kW 99.6/11.2 Useful heat output 80°C - 60°C kW 97.6/11.0 Useful heat output 50°C - 30°C kW 106.0/12.0 80°C - 60°C Full load % 98.0 50°C - 30°C % 106.4 Part load (30%) % 109.0 Efficiency (net) NOx emissions Class 5 Gas supply (natural gas G20) Supply pressure mbar 20.0 Flow rate max/min m3/h 10.54/1.19 Supply pressure mbar 37.0 Flow rate max/min kg/h 7.8/0.88 Maximum operating pressure bar 6 Hot water content litres 12.8 Height mm 1650 Width mm 704 Depth mm 410 Weight (empty) kg 150 TRAVERSE FLAME CERAMIC BURNERS The ECONCEPT 101 modules feature premix ceramic burners with reverse micro-flame, each made up of six plates fastened via a special gasket to a metal frame capable of absorbing thermal expansion. These burners have very low polluting emissions, both NOx and CO2. HEAT EXCHANGERS The heat exchangers design, build and materials ensure high efficiency, constant performances reliability. CASCADING OPERATION The ECONCEPT101 series modules have been developed for connection in series to make up a single heat generator that, in steps of 50kW, can have a total output of around 500kW. Each with electronic programming to ensure the optimum operation from 11kW to 500kW. Gas supply (LPG G31) Central heating Dimensions, weights, fittings Gas fitting DN50 Central heating fittings DN80 Power supply Max power input W Power supply voltage/frequency V/Hz Index of protection IP 380 230V/50Hz X5D 9 13 Energy Top – Floor standing Floor standing cabinet heat generators featuring a premix burner, condensing operation, very high efficiency and very low polluting emissions Suitable for heating systems only, featuring high energy savings and are environmentally-friendly (4 star energy rating). Cascading connection of multiple generators can be performed using special flue gas and water circuit accessories. The models are configured for operation on natural gas but can be converted to LPG using a special conversion kit. Features and Benefits Low emissions – NOX and CO2 Individual and multiple configurations 4 star energy rating Painted steel insulated cabinet, with reversible door (left-right) for B80 and B125 units only Natural gas and can be converted to LPG using a special conversion kit The range features four sizes, two with single burner and two with double burners Cascade configurations suitable for different types of flue options Boiler manifold can be bolted directly together; minimises use of space and installation time Can be used on pressurised or open vented systems where min. 1 bar is available 2 year * parts & labour Guarantee The water circuit in cabinet modules, compared to the wall-hung versions, is already included as standard with all the components required for complete and correct installation in the boiler room. Each unit is connected to the central heating outlet and return water manifolds via 3-way on-off valves with atmospheric discharge and fixed speed pump. 10 14 Technical specifications B80 B125 B160 B250 Output and Efficiency Heat input, central heating Heat output, central heating Efficiency max. kW 75.0 116.0 150.0 232.0 min. kW 17.0 25.0 17.0 25.0 max. (80 - 60°C) kW 73.5 113.7 147.0 227.4 min. (80 - 60°C) kW 16.7 24.6 16.7 24.6 max. (50 - 30°C) kW 79.5 123.0 159.0 246.0 min. (50 - 30°C) kW 18.3 26.9 18.3 26.9 Pmax (80 - 60°C) % 98.0 98.0 98.0 98.0 Pmin (80 - 60°C) % 98.5 98.5 98.5 98.5 Pmax (50 - 30°C) % 106.0 106.0 106.0 106.0 Pmin (50 - 30°C) % 107.5 107.5 107.5 107.5 30% (30°C) 109.0 109.0 109.0 109.0 ★★★★ ★★★★ ★★★★ ★★★★ % Efficiency class Directive 92/42 EEC NOx class 5 5 5 5 Central heating operating pressure max-min. bar 6-0.8 6-0.8 6-0.8 6-0.8 Central heating temperature °C 95 95 95 95 °C 40 40 40 40 litres 13 15 26 30 max. Max exchanger Δt Water content Electrical specifications Index of protection IP X5D X5D X5D X5D V/Hz 230/50 230/50 230/50 230/50 W 285 390 570 780 Weight kg 110 115 190 210 Height mm 1700 1700 1700 1700 Width mm 500 500 1000 1000 Depth mm 450 450 450 450 Outlet/return fittings inches DN100 DN100 DN100 DN100 Gas fitting inches DN65 DN65 DN65 DN65 Power supply voltage Max power input (not including the pump) Structural characteristics Water circuit Combustion data, single furnace Type of appliance B23 B23 B23 B23 Losses through the stack with burner ON at Pmax-Pmin % 2.2-1.3 1.8-1.3 2.2-1.3 1.8-1.3 Losses through the casing with burner ON at Pmax-Pmin % 0.2-0.2 0.2-0.2 0.2-0.2 0.2-0.2 Losses through the stack with burner OFF % 0.03 0.02 0.03 0.02 Losses through the casing with burner OFF % 0.4 0.4 0.4 0.4 Flue gas temperature at Pmax-Pmin (80/60) °C 65-60 67-60 65-60 67-60 Flue gas temperature at Pmax-Pmin (50/30) °C 43-33 45-34 43-33 45-34 Flue gas flow-rate at Pmax-Pmin kg/h 126.2-30.1 Condensate flow-rate at Pmax-Pmin kg/h 8.7-2.0 13.5-3.2 8.7-2.0 13.5-3.2 % 9.0-8.5 9.0-8.5 9.0-8.5 9.0-8.5 CO2 at Pmax-Pmin (G20) CO2 at Pmax-Pmin (G31) 195.2-44.3 126.2-30.1 195.2-44.3 % 10-9.2 10-9.2 10-9.2 10.-9.2 CO weighted mg/kWh 35.0 35.0 35.0 35.0 NOx weighted mg/kWh 29.0 29.0 29.0 29.0 11 15 Yo u r I n s t a l l e r G u i d e General The following notes are provided as a guide, however installers and operators should fully acquaint themselves with the more detailed guidance provided in the relevant installation manual. For copies of such manuals please consult our technical department or visit our website - www.powrmatic.co.uk Standards Ferroli cast iron boilers must be installed, commissioned and operated with due regard to appropriate regulations, relevant Codes of Practice which may include but is not limited to BS5410, BS6644, BS6880 and the possible requirements of Local Authorities, Fire Officers and insurers as well as Powrmatic’s installation manual. Position & Location Boilers should be installed on a level non-combustible base. It is important that any plinths and supporting structures have due regard to the relevant weight loadings. Water Treatment Water quality used with boilers can have a significant effect on both the efficiency of the boiler and also the life expectancy of the boiler. Water supply quality may adversely affect the efficiency and performance of boilers and boiler systems. The situation can intensify where higher temperatures or demands exist. Central heating systems should be thoroughly cleaned and flushed out before installing a new boiler. Guidance can be found in BSRIA BG 29/2011 Pre-Commission Cleaning of Pipework Systems. Additional physical treatment should be evaluated for the removal of oxygen and filtration of the system water. During final filling of the system, a chemical water treatment formulation should be added to the primary circuit to control corrosion and the formation of scale and sludge. Reasonable provision would be to follow the guidance on how to prepare and commission systems given in BS 7593. Chemical water treatment must be introduced in a controlled manner and with a facility for monitoring the water quality to ensure effective treatment is maintained. The chemical concentration of the system water should be regularly checked (especially after the event of any leaks being detected) to ensure it remains effective. Consideration should also be given to flue routes and points of exit, gas, oil, electrical and control connections. Boiler Protection Plant Room or Enclosure Locations Specific requirements may need to be applied where boilers are to be installed within plant rooms or enclosures. Such requirements cover the provision of ventilation for combustion air and general plant room or enclosure ventilation. It is recommended that you consult with our technical department or the installation manual prior to installation. To mitigate acidic condensation measures should be taken to ensure that return water temperatures exceed 60°C within ten minutes of commencement of each firing cycle. In addition it may be considered necessary to consider the inclusion of back-end protection pumps. Each boiler should be fitted with a pump over-run device so that the circulating pump operates for a minimum of thee minutes after the termination of each firing cycle. Installation Clearances Particular clearances may be necessary for the correct and safe function of the boiler as well as for maintenance purposes. Such clearances are confirmed in the relevant installation manual. Flue Each boiler requires a separate flue system of the appropriate size. The flue should essentially be installed in the vertical plane and the number of bends kept to a minimum. Guarantee Powrmatic boilers are provided with a comprehensive guarantee covering both the boiler and the individual cast iron sections. For United Kingdom sales the boiler has the benefit of a two year parts and labour guarantee whilst the cast sections have the benefit of a five year warranty. All guarantees and warranties are subject to terms and conditions. The flue must be adequately supported and terminated with a suitable cowl,with due regard to the point of exit and it’s proximity to any windows, doors or ventilation intakes etc. Powrmatic Ltd Hort Bridge Ilminster Somerset TA19 9PS Powrmatic Ireland 45 Broomhill Close Tallaght Dublin 24 tel: +44 (0) 1460 53535 fax: +44 (0) 1460 52341 e-mail: info@powrmatic.co.uk web: www.powrmatic.co.uk tel: +353 (0) 1452 1533 fax: +353 (0) 1452 1764 e-mail: info@powrmatic.ie web: www.powrmatic.ie Powrmatic pursues a policy of continuous improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the Company to confirm whether any material alterations have been made since publication of this brochure. Issue 5 February 2014