S2700 S3700 S5700 6700快速安装指南07(英文)
Transcription
S2700 S3700 S5700 6700快速安装指南07(英文)
Installing the Device on a Worktable(The S6700 cannot be placed on a worktable) S2700/3700/5700/6700 Series Ethernet Switches Adhibit the rubber pads. Install the device on a worktable. Quick Installation Guide Part number: 31504991 Rev: 07 The device model is on the product nameplate. Service and Support Tool List Crosshead screwdriver Claw hammer Flathead screwdriver Adjustable spanner Marker pen ESD-preventive M6 Plug bolt Cable tie Percussion drill (φ8 Drill bit) Optical fiber bundling tape Huawei Technologies Co., Ltd. Address: Administration Building, Huawei Technologies Co., Ltd.,Bantian, Longgang District,Shenzhen,People’s Republic of China Email: support@huawei.com Website: http://www.huawei.com Postcode: 518129 Diagonal pliers Rubber pads Installing the Device on a Wall ● ● ● ● ● The S6700 and S5710-EI cannot be wall-mounted. To prevent injuries, check that there is no electrical wire at the locations to be drilled before drilling holes in the wall. When the 220 mm depth chassis of an S2700 or S3700 is mounted on the wall, use two screws to install the rack-mounting ear onto the chassis. When a device is mounted to the wall, the front panel must face down to prevent water. Ensure that there are no flammable or explosive materials near the switch and no sundries within 100 mm around the switch. Fix the rack-mounting ears. Accessories Install the plug bolt. M4 φ8 Drill bit M6 plug bolt Rubber pads Captive nut M4 screw Long Short AC terminal M6 screw loose-proof pinch rack-mounting ear rack-mounting ear Rear rack-mounting ear(S5710 -EI) Front rack-mounting ear(S5710 -EI) 90。 Precautions ● Before installation, take ESD-preventive measures, for example, wear ESD-preventive gloves or a wrist strap. ● When the devices without fans are piled, ensure that the distance between each two devices is no less than 1U. ● Leave at at least 50 mm space beside and behind the chassis to allow for cooling air circulation. ● The AC terminal loose-proof pinch is used only when the switch is placed on a desk or wall-mounted. Install the device on the wall. Mark the hole locations on the wall according to the device installed with rack-mounting ears. Installing the Device in a Cabinet ● When the ground screw is located on one side of the switch, the ground cable cannot be connected when the switch is in a cabinet. Connect the ground cable before installing the switch in the cabinet. ● The S6700 chassis is 420 mm in depth. To fix the S6300 chassis securely in a rack, install guide rails in the rack. ● When the 220 mm depth chassis of an S2700 or S3700 is installed in a cabinet, use two screws to install the rack-mounting ear onto the chassis. ● The dimensions of RPS1800 chassis are 442 mm x 310 mm x 43.6 mm (W x D x H) and can be installed only in a 19-inch IEC cabinet. ● The RPS1800 can use only short rack-mounting ears, which are installed at two ends and middle of each side. 2 Fix the captive nuts. 1 Fix the rack-mounting ears. A B 1U=44.45mm C 1U M4 M4 IEC cabinet (19 inch) D S2700-9TP-SI/EI ETSI cabinet (21 inch) E S5710-EI ● The power supplies and fan modules are hot swappable, but service cards are not. (The service cards of S5700-28C-HI, S5700-28C-HI-24S, S5710-28C-EI, and S5710-52C-EI are hot swappable.) M4 IEC cabinet (19 inch) Installing and Removing the Modules 3 Install the device in a cabinet. Installation of the power supply module. Removal of the power supply module. Installation of the front-access service module. Installtion of the rear-access service module. M4 >=1U IEC cabinet (19 inch) M6 IEC cabinet (19 inch) ● A 4-port GE optical interface card or 4-port 10GE optical interface card must be installed together with an external channel card (except on an S5700-28C-HI or S5700-28C-HI-24S). Otherwise, the interface card cannot work. ● Remove blank panels before installing service modules. Copyright © Huawei Technologies Co., Ltd. 2012. All rights reserved. Remove the filler panel from the power module slot on the RPS1800. √ Install the RPS module. × Optical fibers Ethernet cables ● Hold the upper edge of the filler panel and pull the filler panel downward (1). Do not pull the filler panel horizontally (2). Cable tie Power cables ● Move the white button leftward to loosen the handle, and pull out the handle (1). ● Install the power supply into the slot and push the handle inside (2) ● Move the white button rightward to lock the handle (3). To remove the RPS module, reverse the steps (3-2-1). Fiber bundling tape PGND cable Connecting PGND Cables and Power Cables Connect the PGND cable. Connect the DC power cable. Installation of stack cables ● For how to install stack cards of the S5700, see the installation of the rear-access service module. ● The S5700 uses PCI-E cables, or SFP+ stack cables to connect stack interfaces on the ETPC card or the specified interfaces. ● The S5700-LI supports 1-meter passive SFP+ stack cables and 10-meter active SFP+ stack cables that are used to connect to the last two SFP uplink optical interfaces. The bandwidth is 2.5 Gbit/s when 1-meter SFP+ stack cables or stack optical modules are used; the bandwidth is 5 Gbit/s when 10-meter SFP+ stack cables are used.The S5700-LI also supports SFP+ stack optical modules. ● The S5710-EI supports 1-meter and 3-meter passive SFP+ stack cables and 10-meter active SFP+ stack cables that are used to connect to 10GE interfaces. The bandwidth is 10 Gbit/s when SFP+ cables are used. ● The S5700S-28P-LI-AC and S5700S-52P-LI-AC do not support stacking. ● The S6700 supports stack using service interfaces. It supports a maximum of eight stack interfaces,and 1-meter, 3 meter and 10-meter SFP+ stack cables. Connect the AC power cable. Installation of stack cables. S5700 I 1:1 S3700 S6700 I Connect the RPS power cable. A B +12V RTN C RPS1800 ● Do not connect power cables when the device is powered on, so as to avoid injuries. ● Do not power on the device before device installation and cabling are completed. ● Make sure that the protection grounding cable of the device is grounded. ● The S6700 can use only AC power supply. ● A switch can use two types of RPS cables, as shown in Figure A and Figure B. ● Figure B and Figure C show the RPS cable connection. Figure B shows how an RPS cable is connected to a switch. Figure C shows how an RPS cable is connected to an RPS1800. Laying out Cables Removal of stack cables. S5700 S3700 Port number used in installing stack cables of the S3700. Model Port Number S3700-28TP S3700-52P 25/26 49/50 ● Do not stare at optical interfaces. The optical fiber contains laser light sources that hurt human eyes. ● Lay out and bundle power cables, optical fibers, and Ethernet cables separately, with the distances in between longer than 10 cm. During the cabling, if the quantity of cables is rather great, you can route the cables in the cabinet first, and then install connectors to the cables. Copyright © Huawei Technologies Co., Ltd. 2012. All rights reserved.