- Pezzuco Construction
Transcription
- Pezzuco Construction
SUBMITTAL TRANSMITTAL FORM 111 CHESTNUT STREET PROVIDENCE, RI 02903 T 401 831 1240 F 401 331 1945 www.durkeebrown.com Job #: 1040 PROJECT: Phoenix Apartments Date: TRANSMITTED BY: Julie McCullough Spence Providence, RI 5/31/2012 TRANSMITTED TO: Dan Valcourt DBVW Architects Pezzuco Construction 111 Chestnut Street Providence, RI 02903 Contr Ref # Date Rec'd Specification Section Description Item 260000.3 5/14/2012 260000 Electrical Lighting 3 Remarks: See notes as marked. # Rev copies Reviewer 0 E Julie McCullough Spen Action: Resubmit for Record Copy to: This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Corrections or comments made on the shop drawing during this review do not relieve the contractor from compliance with the requirements of the plans and specifications. Approval of a specific item shall not include approval of an assembly of which the item is a component. Contractor is responsible for: dimensions to be confirmed and corrected at the Jobsite; Information that pertains solely to the fabrication processes or to the means, methods, techniques, sequences, and procedures of construction; and coordination of his/her work with that of all trades. Shop Drawing Review Engineering Design Services, Inc. P.O. Box 986 141 Industrial Highway Slatersville, RI 02876 Tel: 401-765-7659 Fax: 401-765-2984 Send to: Pezzuco Construction, Inc. Attention: Daniel Valcourt Project Name: Phoenix Village Submittal No: Section 260000-3 Approved 9 Approved with Comments Does not Conform Resubmit For Final Review Reviewed From: Ray Dusseault Date: May 15, 2012 EDS Proj. No.: 10461RS Item: Lighting Comments: All fixtures except type “S8” are approved as submitted. Signed: (peachtree fixture) R.W.Dusseault III, PE R.W.Dusseault III, PE Note: Final acceptance is contingent upon approval of the Owner and Architect. All comments must be addressed in writing by the Contractor. Refer to General Requirements for the substitutions of equipment and submittal of shop drawings. If apparatus or materials are substituted for those specified, and such substitution necessitates changes in, or additional connections, piping, supports, or construction, it shall be provided. Contractor to assume cost and entire responsibility thereof. The approval of the equipment does not relieve the contractor of responsibility of shop drawing errors related to details, sizes, quantities, wiring diagram arrangements and dimensions which deviate from the Specifications, and/or job conditions as they exist. It is the contractor's responsibility to submit only those items that meet these codes. Should any non-conformance code items be installed, they shall be replaced by the contractor at no additional cost to the owner. Please note that the construction means and methods used in the project shall be reviewed and approved through the building department or a deputy inspector to insure compliance with the current codes, project specifications and general building practices. P:\2010 Projects\10461RS\Submittals\Electrical\Rec'd 05.15.12\Lighting.doc Pezzuco Construction, Inc. 28 Kenwood Street Cranston, RI 02907-3142 Ph : (401) 942-2244 Submittal Job: 11-008 Spec Section No: 260000 Submittal No: 3 Revision No: 0 Sent Date: 5/14/2012 Phoenix Apartments Scattered Addresses Providence, RI 02907 Spec Section Title: Submittal Title: Light Fixtures Contractor: Pezzuco Construction, Inc. Daniel G. Valcourt Note: Vendor is searching for equal to Peachtree fixture (mis-marked as S8) in submittal. Apparently this company is out of business. Vendor is searching for a replacement fixture Type S9. Will be submitted separately. Architect: Durkee Brown Viverios Werenfels Contractor's Stamp REVIEWED Pezzuco Construction, Inc. 5/14/2012 Architect's Stamp Proposed alternate to peachtree fixture: Access Lighting 20356 Oceanus Wet Location Ceiling Fixture Engineer's Stamp Provide Hunter 23910 Low Profile 48" Ceiling fan with Light in White. provide fluorescent lamping, typical Match S3 submitted for 570 Cranston 570 Cranston Street Fixtures Vendor misidentified the S9 fixture in submittal. It should have been marked S8. See attached correction. Vendor is searching for equal to Peachtree fixture (mis-marked as S8) in submittal. Apparently this company is out of business. Vendor is searching for a replacement fixture Type S9. Will be submitted separately. Provide Hunter 23910 Low Profile 48" Ceiling fan with Light in White. Fixture shown on plans not consistent with schedule. Provide Access 207030 Atom semi-flush/ pendant (similar to P1) 25.25" dia. Provide high efficiency electrontic ballast Confirm field conditions allow for recessed fixture at Stair 2. OK to change to S5. Please use this S3 at all buildings. Please use W1 to match other buildings instead. Parking Lot Lighting Fixture