Fitting Instructions
Transcription
Fitting Instructions
CFI365C Minima Hinged Enclosures Do not use the enclosure for at least 24 hours These instructions cover the following units. Please read and ensure all steps have been followed, as this will generally resolve any installation issues Lay a thin bead of sealant around the threshold and the bottom channels. 24hrs 13 301 302 305 14 331 333 332 336 362 360 362 363 Fitting Instructions 364 SECTION 9 • FINISHING OFF The Daryl Care Programme BOW DOOR HANDLE Remove screw ’A’ and then remove the inner handle. Keeping your enclosure beautiful throughout its lifetime is easy with products from the Daryl care programme Using state of the art bespoke machinery combined with the latest technology, all Daryl doors and panels are coated with a glass protector in highly controlled factory conditions. The protector acts as an invisible barrier on the glass to prevent build up of limescale, soap scum, stains and dirt. The factory applied protector will last from months to years depending on use and the hardness of water in your area. It will never crack, peel, discolour or build up. Coated surfaces are kept clean simply by rinsing or wiping with a damp cloth and regular use of Daryl Glass Cleaner. There are two separate elements to caring for your Daryl shower door, enclosure or bath screen. 1 Daryl Glass Cleaner for the regular cleaning of your shower door, enclosure or screen 2 Daryl Care Kit comprising of Glass Treatment and Glass Protector suitable for use where glass protector has not already been applied or for topping up factory coated protector Daryl Glass Cleaner For occasional cleaning of glass treated with Daryl Glass Protector or for more regular maintenance of untreated surfaces, we recommend using Daryl Glass Cleaner. The Cleaner cleans and polishes without smearing or streaking and rejuvenates the Glass Protector. Daryl Glass Treatment and Daryl Glass Protector Available in one care kit, the Treatment and Protector are used on new or existing shower installations where Protector has not already been applied and for topping up factory coated glass after a reasonable length of time. The Treatment must always be used on existing shower installations to prepare for the Protector. The Treatment is a cleaning material that is applied to the glass to ensure it is in the cleanest condition possible prior to application of the Protector. If this process is not undertaken, there is the likelihood of locking in dust, dirt and stains under the Protector. Daryl Protector acts as an invisible barrier on the glass to prevent the build up of lime scale, soap scum, stains and dirt. Applied like a polish, one application will last from months to years depending on use and the hardness of water in your area. It will never crack, peel, discolour or build up. Coated surfaces are kept clean simply by rinsing or wiping with a damp cloth and regular use of Daryl Glass Cleaner. 2 CFI365C Check that the 2 gaskets ‘C’ and the sleeve ‘D’ are in position. Fit the pin through the hole in the glass. Reattach the inner handle. Refit and tighten screw ‘A’ ensuring it is facing downwards. Regular cleaning • Mildew thrives in damp, unventilated areas. It is, therefore, important to always wipe down, with a soft cloth or towel, the glass and metal sections inside the shower every time it is used A A D • Do not allow water to remain on glass and metal sections for long periods of time C • Every week or two, use Daryl Glass Cleaner to polish the enclosure (including metal sections) ensuring all surfaces are wiped down • In hard water areas, do not allow lime scale to build up. Stubborn deposits of lime scale can usually be removed by using a 50:50 solution of vinegar and water, which should be rinsed off thoroughly and dried after use E Remove screw ‘B’ and the spacer. B B • Regular cleaning is required to remove the small amounts of residue that are not repelled by the Protector Everyday Care Wipe down the glass and metal sections with a soft cloth or towel and warm water after each time the shower is used. Do not allow water to remain on glass and metal sections for long periods, do not allow the build up of lime scale and do not use caustic cleaners or abrasives. F E 9 Check that the 2 gaskets ‘E’ are in position. Fit the sleeve in the hole ‘F’ in hole the glass. Refit screw ‘B’ and tighten. 10 ‘U’ SECTION WALL CHANNEL: Seal between the wall channel and the wall. STANDARD WALL CHANNEL: Seal between the wall channel and the wall. Daryl showers trays If you have a Daryl shower tray scuffs and marks on acrylic trays can often be removed by the light use of a mildly abrasive cleaner applied with a damp cloth and polished off. Other cleaning materials Ensure that if you use a non-Daryl cleaning product, it has a pH level between 4 & 8 and is non-abrasive. Prolonged use of cleaners with a pH level outside the specified range can cause damage to metal sections and possibly affect the safe operation of your Daryl Shower. All cleaning material (including Daryl’s) must be wiped down after application. Do not use ‘spray and leave’ cleaning products on the metal surface as these may cause damage to your door or enclosure. Kohler Daryl Limited Alfred Road, Wallasey, Wirral, CH44 7HY England Tel 44 (0)151 606 5000 Fax 44 (0)151 638 0303 www.daryl-showers.co.uk E-mail Daryl@daryl-showers.co.uk 11 12 CFI365C 39 SECTION 9 • FINISHING OFF STANDARD WALL CHANNELS: Cut the seals exposed at top with a sharp knife. Contents STANDARD WALL CHANNELS: Fit the top caps. There are many options within the Minima Range and these instructions give a step by step procedure for fitting all units. Each section covers all enclosures unless otherwise stated. G Tip: Look for the small drawings of the enclosures to identify your unit in each section. Fit the screw covers. 5 6 OBLIQUE DOOR HANDLE ROUND DOOR HANDLE Remove screw ’A’ and then remove the inner handle. A Spacer found in main parts pack Introduction Page 4 Safety Precautions Page 4 Care & Maintenance Page 4 Components Page 5 Section 1 - Positioning the wall channels Page 8 Section 2 - Fitting the wall channels Page 13 Section 3 - Fitting the channel guides Page 14 Section 4 - Fitting panels Page 23 Section 5 - Checking door gaps Page 25 Section 6 - Fitting bracing bars Page 29 Section 7 - Fitting the door Page 31 Section 8 - Fitting the closing door seal Page 35 Section 9 - Finishing off Page 37 Check that the 2 gaskets ‘B’ and the sleeve ‘C’ are in position. Fit the pin through the hole in the glass. Reattach the inner handle. Refit screw ‘A’, turn handle to the desired orientation and tighten the screw. If your installation needs the hinges to be on opposite side of the enclosure to that shown in these instructions All units with the exception of extended pentagons and enclosures with bonded panels are reversible. Doors and panels can be turned through 180o as required and fitting is a mirror image of those shown. B C Extended pentagons and bonded panels are supplied handed and fitting is a mirror image of those shown. B A 7 38 CFI365C 8 CFI365C 3 SECTION 9 Introduction FINISHING OFF • ALL VERSIONS The following pages aim to provide comprehensive installation instructions, plus advice on how to care and maintain your product. We recommend that the unit is installed by a qualified Plumber or Engineer. Please retain this document for future reference. Note: Due to our desire to always improve our products, Daryl reserve the right to change specification without prior notice. Place the threshold on the floor or tray. UNITS WITH WALL MOUNTED HINGES ONLY Using a fine toothed hacksaw cut the threshold at the wall end at 90o. Safety Precautions Caution: Care should be taken when drilling into walls and floors to avoid any hidden pipes or wires. We strongly recommend that all glass panels are moved by a minimum of two people and that any protective packaging along the glass edges is kept in place for as long as possible to prevent damage before installation. Wear protective footwear when lifting panels Wear safety glasses when drilling People not familiar with the fitting of Daryl Products may require the assistance from another person at certain stages of the procedure. We have indicated these points in the process with the Caution Symbol. 364 362 362 90o A 362 - With side panel. Cut at wall end only. ‘A’ = Width of door glass PLUS 15mm. 362 - With bonded panel. Cut at wall end only. ‘A’ = Width of door glass PLUS 30mm. 364 - Cut BOTH ends. ‘A’ = Distance between walls. Ensure the area around the threshold is clean and dry before fitting 301, 333 - Place one end against the wall channel. 302 - Place one end to the outer edge of the side panel. 305 - Place in original marked position. 331, 332, 336, 363 - Place equally about the centre line of the door. 360, 362 - Place cut end(s) against the wall. 2 1 Fit the splashguard to the bottom of the door. ALL UNITS: Move the threshold forwards by 5mm. Caution Care & Maintenance The unit should be wiped down immediately after each use. Use a non abrasive cleaner with a pH value between 4 & 8, applied with a soft cloth. A 50:50 solution of vinegar & water can be used on lime scale deposits, rinsing off thoroughly after use. Do not use alkalis such as caustic soda. Under no circumstances should scourers or powerful detegents be used as these can damage the metallic surface of the frame and the surface of the tray or bath, and also tarnish the glass coating. If fitted correctly the unit should not require any maintenance other than cleaning. If problems do occur contact the Daryl Technical Helpline Tel: 0151 606 5000 4 CFI365C Made in the UK by: Kohler Daryl Limited Alfred Road, Wallasey, Wirral, CH44 7HY England Tel 44 (0)151 606 5000 Fax 44 (0)151 638 0303 5mm Locate the threshold by pulling a small amount of the backing off each end. When threshold is in the correct position remove rest of backing and secure in place. Ensure the splashguard clears the threshold when door opens. Inside of enclosure. 3 4 CFI365C 37 SECTION 8 • FITTING THE DOOR CLOSING SEAL Components x2 +1 x2 +1 360 320 360 323 x2 x2 +1 337 300 Proceed to Section 9 363 360 362 Panel 36 CFI365C x2 x2 x2 x2 +1 x2 321 300 300 Threshold Threshold Door Seal (Hinge side and/or closing side) Door Seal (Closing & hinge side) Door Seal (Closing side) Door Seal (Closing & hinge side) Door Seal (Closing side) Cover Strip ‘U’ Section Wall Channel (also used for marking position of wall mounted hinges) 4 x Screw These items are delivered fitted together. Undo the allen screws to separate. x2 Glass Clamp A Included Panel Standard Wall Channel 3mm Part used as a template only and is not installed (’+1’ signifies extra components not needed for installation) 321 301 Door Proceed to Section 9 +1 x2 324 300 330 321 320 300 305 362 302 302 IMPORTANT The gap between the edge of the door and the side of the door seal should be 3mm. Adjustment 302 - Undo the glass clamp on the door panel enough to allow the panel and door assembly to move. Adjust until the gap is 3mm then retighten the glass clamp screws. Adjustment 362 - A small amount of adjustment can be achieved by adding extra gaskets under the hinge brackets. 331 Fit door stop seal to the end of the panel 322 321 332 DOOR TO SIDE PANEL x2 337 362 Parallel x2 Door 333 336 337 305 IMPORTANT The gap between the edge of the door and the side of the door seal should be parallel from top to bottom. 360 360 IMPORTANT Adjust seal until it is 3mm from edge of door. 336 3mm 362 332 Door x2 337 337 330 331 324 300 305 Panel 363 Move seal in or out to adjust 337 331, 332, 336, 360 + inline panel, 362 + bonded panel, 363. 364 Fit door stop seal to the end of the panel 364 DOOR TO INLINE PANEL OR BONDED PANEL CFI365C 5 6 CFI365C C 45o Bracing Bar Assembly x2 Channel Guide Bottom Channel Plug Top Cap (LH/RH) Cap 90o Bracing Bar Assembly C Cap B x2 Wall Mount Hinge Assembly 135o Hinge Assembly 180o Hinge Assembly Splashguard (’+1’ signifies extra components not needed for installation) Option Included 300 +1 +1 x2 x2 321 301 x2 x2 x2 x2 321 300 302 320 322 321 x2 330 321 331 x2 324 300 332 337 300 x2 333 337 x2 324 300 336 337 323 x2 360 360 x2 360 362 320 360 x2 362 x2 x2 x2 x2 x2 x2 x2 x2 x2 x2 x2 x2 x2 +1 +1 +1 +1 x1 with each side panel 1200mm or more +1 x1 with each hinge panel and inline panel 400mm wide or more x1 with side panel up to 1000mm x1 for bonded panel with hinges. x2 for 363 unit only. x2 with pentagon unit x2 300 305 x2 x2 x2 x2 337 337 330 363 337 x2 364 364 Components SECTION 8 FITTING THE CLOSING DOOR SEAL DOOR TO WALL • STANDARD WALL CHANNEL Fit the door stop seal into the wall channel. Do not fully tighten screws 301 333 IMPORTANT Adjust door seal until it is 3mm from edge of door, then fully tighten screws 3mm Move seal in or out to adjust A x4 Proceed to Section 9 DOOR TO WALL • ‘U’ SECTION WALL CHANNEL Push the cover strip into the wall channel then fit the door seal (use the unnotched seal). IMPORTANT Adjust door seal until it is 3mm from edge of door. 364 3mm Move seal in or out to adjust INSIDE Proceed to Section 9 CFI365C 35 SECTION 7 • FITTING THE DOOR x3 x6 x2 x2 x6 x3 x3 x3 x3 x4 x4 x6 x2 x2 x8 x6 x2 +1 x6 300 7 x6 x6 x2 x2 x6 x2 x6 x8 x2 x2 x2 x6 x8 330 321 322 321 34 CFI365C x6 x2 Wall Plug D G F Wall Plug x6 x2 +1 E x6 3mm 2mm 3mm Allen Keys Bow Handle Assembly Oblique Handle Assembly Round Handle Assembly Screw Cover x2 x6 x8 2.5mm 9 4mm 8 (’+1’ signifies extra components not needed for installation) Proceed to Section 8 Option Included 321 x8 300 301 321 300 302 320 300 305 x6 x8 324 300 Start to close the door. As the fin of the seal touches the wall brackets, using a sharp knife, make slits in the seal at the top and the bottom of the brackets. 331 Fit the seal to the hinged side of the door, notch at the bottom (use appropriate seal, two are supplied for left or right hand installations). 332 337 6 x8 333 337 Caution x6 337 360 x3 320 323 360 362 324 300 B 360 B 336 Note: If necessary, adjust position of door by removing the back plates and rotating eccentric spacers. Replace back plates and tighten all screws as tight as possible. Retighten after 10 minutes. 360 362 x4 337 337 330 x8 363 337 364 x5 x5 Components Check that the door is vertical. 364 Carefully lift the door into place. IMPORTANT: Keep the door supported at all times. Fit 4 screws to secure the hinges to the wall. CFI365C 7 SECTION 7 • FITTING THE DOOR SECTION 1 POSITIONING THE WALL CHANNELS Remove the back plates from the hinges. The height and angle of the door is set by eccentric spacers, turn the spacers using a flat screwdriver. The positions shown below are recommended as an initial setting, so the glass is at a slight angle prior to the weight being taken by the hinge. Further adjustment can be achieved by adding spacer gaskets behind the hinge mounting brackets. DOOR WITH HINGES FITTED TO AN INLINE PANEL Models: 360, 362, 364 Important: Ensure the door is fully supported at all times. m 20m 301 331 Eccentric Spacers The dimensions shown will set the door approximately 30mm from the front of the tray, but this can be adjusted if required. WET ROOM FITTING ONLY: Mark equal distance from back wall on both sides. If a seat is being fitted the distance from the back wall to the glass MUST be between 750 & 950mm. Spacer gaskets IMPORTANT Tray must be level in all planes or enclosure will not install properly. Door Wall 3 2 Proceed to Section 2 DOOR WITH HINGES FITTED TO AN INLINE PANEL AND CLOSING TO A SIDE OR BONDED PANEL Fit the hinges to the panel. NOTE: Coated side of glass goes to the inside. Open the hinges out (as if the door was open). A 302 332 DIMENSION A Door & Inline Panel(s) 769 ± 8mm 800 869 ± 8mm 900 969 ± 8mm 1000 1069 ± 8mm 1100 1169 ± 8mm 1200 1269 ± 8mm 1300 1369 ± 8mm 1400 1469 ± 8mm 1500 1569 ± 8mm 1600 1669 ± 8mm 1700 B If fitting to a tray ensure tray is level in all planes. Mark dimensions 'A' & 'B', the distances from the outside edge of the wall channels to the tiles. The distance from the outside face of the glass to the tiles will be 7mm less. Check to see if walls are vertical, adjust dimensions if necessary within range shown. DIMENSION B 762 800 900 1000 1200 1400 8 CFI365C Side Panel 731 ± 8mm 769 ± 8mm 869 ± 8mm 969 ± 8mm 1169 ± 8mm 1355 ± 8mm If a seat is being fitted the distance from the wall to the glass MUST be between 750 & 950mm. Proceed to Section 2 4 5 CFI365C 33 SECTION 1 • POSITIONING THE WALL CHANNELS SECTION 7 • FITTING THE DOOR Fold hinge so it is at 90o. Fit the door to hinge ensuring it is fully supported at all times. Fit the hinges to the panel. PENTAGON ENCLOSURE NOTE: Coated side of glass goes to the inside. The back plate with holes further from the edge fits to the panel. Wall channel positions are determined using the threshold - lay the threshold on the tray or floor. DO NOT FIX IN PLACE Caution The back plate with holes nearer to the edge fits to the door. Mark dimension 'A', the distance from the corner of the threshold to the tiles. Check to see if walls are vertical, adjust 'A' if necessary within range shown. IMPORTANT Tray must be level in all planes or enclosure will not install properly. 305 Enclosure 900 1000 1200 1400 The ball catch in the hinge goes to the door side. DIMENSION 'A' 329 ± 8mm 429 ± 8mm 629 ± 8mm 829 ± 8mm BESPOKE ENCLOSURES ONLY: Mark dimension 'A', the width of glass panel minus 24mm, then adjust for lean of wall if necessary. Note: If necessary, adjust position of door by removing the back plates and rotating eccentric spacers. Replace back plates and tighten all screws as tight as possible. Retighten after 10 minutes. B Ensure sealing strip fits behind door B A A Proceed to Section 8 WET ROOM FITTING ONLY: Mark dimension 'A', then measure dimension 'B' from the inside edge of the threshold to the tiles. 1 4 Mark the position of both wall channels on the wall: FITTING A DOOR WITH WALL MOUNTED HINGES Drill 4 x 8mm holes in the wall. C 360 364 C B 8mm TRAY FITTING ONLY: Measure dimension 'C' from the inside edge of the threshold to the outside edge of the tray. Then mark the distance from the edge of the tray to the inside edge of the wall channel (not including seal) to be as measurement 'C'. B Fit 4 x wall plugs. 362 362 The position for the hinge fixing holes should already be marked on the wall - See Section 1, Page 11. C C WET ROOM FITTING ONLY: Mark the distance from the tiles to the inside edge of the wall channel (not including seal) to be as measurement 'B'. Proceed to Section 2 1 32 CFI365C Finally mark the position of the threshold on the tray or floor so that it can be repositioned later. 2 CFI365C 9 SECTION 7 SECTION 1 • POSITIONING THE WALL CHANNELS ENCLOSURES WITH HINGES FITTED TO A BONDED SIDE PANEL FITTING THE DOOR FITTING A DOOR TO AN INLINE PANEL, PENTAGON OR BONDED PANEL A 333 336 DIMENSION A Door & Inline Panel(s) 800 769 ± 8mm 900 869 ± 8mm 1000 969 ± 8mm 1100 1069 ± 8mm 1200 1169 ± 8mm 1300 1269 ± 8mm 1400 1369 ± 8mm 1500 1469 ± 8mm 1600 1569 ± 8mm 1700 1669 ± 8mm DIMENSION B 762 800 900 Side Panel 731 ± 8mm 769 ± 8mm 869 ± 8mm Fit the seal to the edge of the hinge panel. 301 If fitting to a tray ensure tray is level in all planes. B 302 Inside 305 Mark dimensions 'A' & 'B', the distances from the outside edge of the wall channels to the tiles. The distance from the outside face of the glass to the tiles will be 7mm less. Check to see if walls are vertical, adjust dimensions if necessary within range shown. Models: 301, 302, 331, 332, 333, 336, 363 331 332 333 Inside If a seat is being fitted the distance from the wall to the glass MUST be between 750 & 950mm. Model: 305 Proceed to Section 2 336 DOOR WITH HINGES FITTED TO THE WALL CLOSING TO AN INLINE PANEL IMPORTANT: Hinges can only be mounted on a perfectly vertical and flat wall Place the front edge of the U section wall channel template against the marked line. Note: place the channel so the top fixing hole is further in from the end of the channel than the bottom fixing hole (there is 40mm difference). 360 HINGE SIDE The height and angle of the door is set by eccentric spacers, turn the spacers using a flat screwdriver. The positions shown below are recommended as an initial setting, so the door and hinge are at a slight angle prior to the weight being taken by the hinge. CLOSING SIDE 20m m Important: Ensure the door is fully supported at all times. Models: 301, 302, 331, 332, 333, 336, 363 Eccentric Spacers Mark a position 20mm in from the edge of the tray. WET ROOM: The position of the wall channel is set by the fitter. The U section wall channel template should be 7mm nearer the back wall than the standard wall channel on the closing side. Mark a position 27mm in from the edge of the tray. 10 CFI365C Remove the back plates from the hinges. Mark the hinge fixing holes. m 27m The dimensions shown will set the door approximately 30mm from the front of the tray, but this can be adjusted if required. 1 363 27mm If a seat is being fitted the distance from the back wall to the glass MUST be between 750 & 950mm. DISCARD THE TEMPLATE AFTER USE Proceed to Section 2 Model: 305 Door 2 Panel 3 CFI365C 31 SECTION 6 • FITTING BRACING BARS SECTION 1 • POSITIONING THE WALL CHANNELS DOOR ONLY WITH HINGES FITTED TO THE WALL IMPORTANT: Hinges can only be mounted on a perfectly vertical and flat wall FITTING A 90° BRACING BAR TO A SIDE OR BONDED PANEL A Loosen screw 'B' and remove the fixing block from the bracing bar. Measure from the glass to the wall ('X') - maximum 1175mm. B Note: place the channel so the top fixing hole is further in from the end of the channel than the bottom fixing hole (there is 40mm difference). Mark the hinge fixing holes. Loosen screw 'C' at the other end of the bracing bar. Place the bracing bar on top of the glass and at 90o to the panel. Make horizontal. ‘X’ minus 45mm Place the front edge of the U section wall channel template against the marked line. HINGE SIDE 27mm C 1 IMPORTANT Tray must be level in all planes or enclosure will not install properly. The dimensions shown will set the door approximately 30mm from the front of the tray, but this can be adjusted if required. 100mm Cut the bracing bar at the marked point with a fine toothed hacksaw. TRAY FITTING ONLY: Mark a vertical plumb line on the wall from the tray to above the position of the top hinge 27mm from the front edge of the tray. 364 Measure the bracing bar from the inside edge of the glass cutout. Mark a point Dimension ‘X’ MINUS 45mm. X Before fitting the wall channel, mark the fixing position of the hinges on the wall using the wall channel as a template. Deburr the cut end of the bracing bar and refit the section. Ensure the fixings are on top then tighten the screw. Loosen screw ‘A’ at the wall end and remove the end of the bracing bar. WET ROOM FITTING ONLY: The position of the vertical plumb line is set by the fitter. 27mm 1 2 On the closing side, mark the position of the wall channel on the wall. Fit the bracing bar fixing block to the wall. 1 Place the bracing bar on top of the glass at the previous position. 2 100mm 27m m 3 6 B CLOSING SIDE 8mm 4 5 Tighten screw 'C' at the other end to secure the bracing bar to the glass. Fit the cap to the end of the bracing bar. 3 Proceed to Section 7 TRAY FITTINGONLY: Mark a line 27mm from the front edge of the tray. WET ROOM FITTING ONLY: Mark a line on the wall equal to the distance from the wall to the vertical plumb line on the hinge side. C C 30 CFI365C Tighten screw 'B' to secure the bracing bar to the fixing block. Proceed to Section 2 4 2 CFI365C 11 SECTION 1 • POSITIONING THE WALL CHANNELS SECTION 6 DOOR WITH HINGES FITTED TO THE WALL AND CLOSING TO A PANEL IMPORTANT: Hinges can only be mounted on a perfectly vertical and flat wall FITTING BRACING BARS 45° BRACING BARS A Loosen screw 'A' and remove the fixing block from the bracing bar. Fit the bracing bar fixing block to the wall. 2 1 362 362 DIMENSION A Door (& Inline Panel) 668 ± 0mm 700 768 ± 0mm 800 868 ± 0mm 900 968 ± 0mm 1000 1068 ± 0mm 1100 1168 ± 0mm 1200 1268 ± 0mm 1300 1368 ± 0mm 1400 B DIMENSION B 762 800 900 1000 1200 1400 Side Panel 724 ± 8mm 762 ± 8mm 862 ± 8mm 962 ± 8mm 1162 ± 8mm 1348 ± 8mm A If fitting to a tray ensure tray is level in all planes. Mark dimensions 'A' & 'B', the distances from the outside edge of the wall channels to the tiles. For dimension 'A', the distance from the outside face of the glass to the tiles will be 7mm less. Check to see if walls are vertical, adjust dimensions if necessary within range shown. Loosen screw 'B' at the other end the bracing bar. HINGE SIDE 8mm B Place the bar on top of the glass and make horizontal, so centre line of bar is level with top of glass. Place the front edge of the U section wall channel template on the tray or floor and mark the position of the hinge fixing holes. SEE PAGE 10 FOR MORE INFORMATION If a seat is being fitted the distance from the wall to the glass MUST be between 750 & 950mm. 3 6 4 5 Proceed to Section 2 C ENCLOSURES WITH BONDED PANELS ON BOTH SIDES OF THE DOOR 2 1 Place the bracing bar on top of the glass at the previous position. Tighten screw 'B' at the other end to secure the bracing bar to the glass. A B 363 B If fitting to a tray ensure tray is level in all planes. DIMENSION A 1200 1300 1400 1500 1600 Door & Panels 1190 ± 0mm 1290 ± 0mm 1390 ± 0mm 1490 ± 0mm 1590 ± 0mm Mark dimension 'A', the distance across the outside edges of the wall channels. The distance across the outside faces of the glass will be 14mm less. FOR TRAY FITTING ONLY: Dimension 'B' must be equal on both sides. Tighten screw 'A' to secure the bracing bar to the fixing block. B Fit the cap to the end of the bracing bar. A Proceed to Section 7 Proceed to Section 2 12 CFI365C 3 4 CFI365C 29 SECTION 2 SECTION 5 • CHECKING DOOR GAPS DOOR WITH WALL MOUNTED HINGES AND CLOSING TO A SIDE OR BONDED PANEL A FITTING THE WALL CHANNELS The gap between wall and wall channel must be the width of door plus 17 to 19mm at all points 'A'. If adjustment is required remove the side panel and the channel guide. Redrill the hole and fit the channel guide in the new position. Refit the side panel and check the gap between wall and wall channel again. FITTING A STANDARD WALL CHANNEL Note: Glass seal will extend out of wall channel x3 x3 Make the wall channel plumb. 8mm 362 362 Mark the position of the 3 fixing holes on the wall. x3 A A Place the outside edge of the wall channel against the mark on the wall. (Width of door plus 17 to 19mm) Wall channels MUST be plumb x3 Remove the wall channel and drill 3 x 8mm holes at the marked points. Fit 3 wall plugs. D A Screw the wall channel to the wall just enough to hold it in position. Lay a bead of sealant behind the wall channel. (Width of door plus 17 to 19mm) A Fully tighten screws to fix the wall channel to the wall. When the glass is in the correct position, fully tighten glass clamp screws. Retighten the screws after 10 minutes. Check wall channel is plumb. Use slots to adjust if necessary. Proceed to Section 6 Proceed to Section 3 DOOR MOUNTED TO A BONDED PANEL FITTING A ‘U’ SECTION WALL CHANNEL A The gap between wall channel and the edge of the bonded panel (333) or between both bonded panels (363) must be the width of door plus 10 to 12mm at all points 'A'. x5 x5 Place the outside edge of the wall channel against the mark on the wall. 6mm Make the wall channel plumb. x5 333 Mark the position of the 5 fixing holes on the wall. 363 A If adjustment is required remove the side panel(s) and the channel guide(s). Redrill the hole(s) and fit the channel guide(s) in the new position. Refit the side panel(s) and check the gap again. 333 x5 E A Wall channels MUST be plumb Remove the wall channel and drill 5 x 6mm holes at the marked points. Fit 5 wall plugs. (Width of door plus 10 to 12mm) Screw the wall channel to the wall just enough to hold it in position. A 363 A (Width of door plus 10 to 12mm) When the glass is in the correct position, fully tighten glass clamp screws. Retighten the screws after 10 minutes. 28 CFI365C Proceed to Section 6 Lay a bead of sealant behind the the wall channel. Fully tighten screws to fix the wall channel to the wall. Proceed to Section 3 CFI365C 13 SECTION 5 • CHECKING DOOR GAPS SECTION 3 DOOR ONLY WITH WALL MOUNTED HINGES FITTING THE CHANNEL GUIDES DOOR ONLY WITH HINGES FITTED TO AN INLINE PANEL Mark guide position(s) by laying the threshold on the tray or floor DO NOT FIX IN PLACE A The inside edge of the threshold should be 7mm back from the marks made for the wall channel in Section 1. When fitting to a tray visually check that the threshold is parallel to edge of tray. 301 364 331 301: The end of the threshold at the closing side should be 30mm from the wall. 30mm = 7mm A A (Width of door plus 17 to 19mm) 331: Measure the width of each inline panel (they may be different widths). Mark the end position of each panel on the tray or floor. Centre the threshold between the marks. = = Proceed to Section 6 7mm = Drill a hole, for each inline panel 6mm in from the end of the threshold. Drill 3mm for tray fitting. Size of hole for wet room fitting is dependent on floor specification. Installer to supply drill and plugs. 7mm 1 REMOVE THE THRESHOLD Screw the channel guide to tray or floor. DOOR WITH WALL MOUNTED HINGES AND CLOSING TO AN INLINE PANEL A F The gap between wall and wall channel must be the width of door plus 17 to 19mm at all points 'A'. If adjustment is required, move the inline panel in the wall channel. 364 A A 6mm (Width of door plus 17 to 19mm) 90° A Proceed to Section 4 2 14 CFI365C When the glass is in the correct position, fully tighten glass clamp screws. Retighten the screws after 10 minutes. Proceed to Section 6 CFI365C 27 SECTION 5 • CHECKING DOOR GAPS SECTION 3 • FITTING THE CHANNEL GUIDES DOOR HINGED ON AN INLINE PANEL AND CLOSING TO A SIDE PANEL ENCLOSURE WITH HINGES FITTED TO AN INLINE PANEL AND CLOSING TO A SIDE PANEL A Mark guide positions by laying the threshold on the tray or floor The gap between panel and wall channel must be the width of the door plus 10 to 12 mm at all points 'A'. If adjustment is required, move the inline panel in the wall channel. DO NOT FIX IN PLACE A 302 A (Width of door plus 10 to 12mm) A When the glass is in the correct position, fully tighten glass clamp screws. Retighten the screws after 10 minutes. A 302 Dimensions 'A' & 'B' Are the measurements from the outside edges of the wall channels to the tiles, as marked in Section 1. Dimensions 'C' & 'D' Mark 'C' from the tiles to the outer edge of the threshold. Dimension 'C' is 'A' minus 7mm. D B Mark 'D' from the tiles to the inside edge of the threshold. Dimension 'D' is 'B' minus 7mm. When fitting to a tray visually check that threshold is parallel to edge of tray. C Proceed to Section 6 1 PENTAGON ±0mm REMOVE THE THRESHOLD Screw the channel guides to tray or floor Ensure panels are vertical. The gap between panels should be 687mm. If adjustment is required, move the panels in the wall channels. F 305 Drill 3mm holes for tray fitting. Size of holes for wet room fitting is dependent on floor specification. Installer to supply drill and plugs 687mm When the glass panels are in the correct position, fully tighten glass clamp screws. Retighten the screws after 10 minutes. Proceed to Section 6 26 CFI365C 6mm 90° 6mm 40mm 2 CFI365C 15 SECTION 3 • FITTING THE CHANNEL GUIDES SECTION 5 ENCLOSURE WITH HINGES FITTED TO AN INLINE PANEL AND CLOSING TO A BONDED PANEL CHECKING DOOR GAPS DOOR ONLY HINGED FROM AN INLINE PANEL Mark first guide position by laying the threshold on the tray or floor DO NOT FIX IN PLACE A A 332 Dimensions 'A' & 'B' are the measurements from the outside edges of the wall channels to the tiles, as marked in Section 1. Dimensions 'C', 'D' & 'E' Mark 'C' from the tiles to the inside edge of the threshold. Dimension 'C' is 'B' minus 7mm. 301 C B Mark 'D' from the inside of the wall channel to the edge of the inline panel. Dimension 'D' is the width of the panel. The gap between panel and wall channel must be the width of door plus 10 to 12 mm at all points 'A'. If adjustment is required, move the inline panel in the wall channel. E A A (Width of door plus 10 to 12mm) D Mark 'E' from the tiles to the edge of the bonded panel. Dimension 'E' is 'A' minus 7mm, then minus the width of the bonded panel. = Place the threshold centrally between 'D' and 'E'. = A When fitting to a tray visually check that threshold is parallel to edge of tray. Mark second guide position. 1 REMOVE THE THRESHOLD Screw the channel guides to tray or floor A When the glass is in the correct position, fully tighten glass clamp screws. Retighten the screws after 10 minutes. Proceed to Section 6 DOOR HINGED FROM AN INLINE PANEL AND CLOSING TO AN INLINE PANEL OR BONDED PANEL F A B minus 40mm B 331 A minus 13mm 6mm 90° Drill 3mm holes for tray fitting. Size of holes for wet room fitting is dependent on floor specification. Installer to supply drill and plugs A 336 332 The gap between panel and wall channel must be the width of door plus 10 to 12 mm at all points 'A'. If adjustment is required, move the inline panel in the wall channel. A (Width of door plus 10 to 12mm) A Proceed to Section 4 2 16 CFI365C When the glass is in the correct position, fully tighten glass clamp screws. Retighten the screws after 10 minutes. Proceed to Section 6 CFI365C 25 SECTION 4 SECTION 3 • FITTING THE CHANNEL GUIDES PENTAGON FITTING BONDED PANELS B Caution Fit the panel ensuring the bottom channel fits over the channel guide 'A'. Rest glass against seal of wall channel 'B'. B C 305 B Mark guide positions by replacing the threshold in its original position, as marked in Section 1. This will set the inside edge of each side of the threshold in line with the inside edge of each wall channel (not including the seal). Glass needs to be at least 8mm into wall channel. Ensure the white foam strips are still on the bottom edge of the glass, inside the H section. DO NOT FIX IN PLACE 8mm Minimum C A 1 1 Place a blob of sealant at base of wall channel and glass panel. 2 Fit the glass clamp and turn the screw until it lightly grips the glass. Drill holes 6mm in from each end of threshold. Drill 3mm for tray fitting. Size of holes for wet room fitting is dependent on floor specification. Installer to supply drill and plugs Fit the plug at the end of the bottom channel. Keep the panel supported at all times. REMOVE THE THRESHOLD Screw the channel guides to the tray or floor F 6mm A 90° x4 Repeat for a 2nd panel where required. 3 24 CFI365C 4 Proceed to Section 5 Proceed to Section 4 5 2 CFI365C 17 SECTION 3 • FITTING THE CHANNEL GUIDES SECTION 4 ENCLOSURE WITH HINGES FITTED TO A BONDED SIDE PANEL FITTING PANELS A FITTING INLINE PANELS AND SIDE PANELS TO WALL CHANNELS Fit the panel ensuring the bottom channel fits over channel guide 'A'. Rest glass against seal of wall channel 'B'. SUPPORT THE GLASS PANEL UNTIL THE GLASS CLAMP IS FITTED 333 B B minus 40mm A minus 13mm Mark guide position. Dimensions 'A' & 'B' are the measurements from the outside edges of the wall channels to the tiles, as marked in Section 1. Screw the channel guide to tray or floor B Caution NOTE: Coated side of glass goes to the inside. App ro 180m x m Drill a 3mm hole for tray fitting. Size of hole for wet room fitting is dependent on floor specification. Installer to supply drill and plugs. 1 Hinge side has holes If a seat is being fitted, position the glass so the hole in the glass is approximately 180mm from the wall. Glass needs to be at least 8mm into wall channel. Ensure the white foam strips are still on the bottom edge of the glass, inside the H section. 8mm Minimum A 1 Place a blob of sealant at base of wall channel and glass panel. F 2 Fit the glass clamp and turn the screw until it lightly grips the glass. Fit the plug at the end of the bottom channel. Keep the panel supported at all times. x4 A Repeat for a 2nd panel where required. Proceed to Section 5 Proceed to Section 4 2 18 CFI365C 3 4 5 CFI365C 23 SECTION 3 • FITTING THE CHANNEL GUIDES SECTION 3 • FITTING THE CHANNEL GUIDES ENCLOSURE WITH HINGES FITTED TO A BONDED SIDE PANEL ENCLOSURES WITH TWO BONDED PANELS Mark guide positions. Dimension 'A' is the measurement across the outside edges of the wall channels, as marked in Section 1. Dimension 'B' is 'A' minus 26mm, marked equally about the centre line. Dimension 'C' is the depth of the bonded panels minus 40mm. Mark first guide position by laying the threshold on the tray or floor DO NOT FIX IN PLACE A A 336 363 Dimensions 'A' & 'B' are the measurements from the outside edges of the wall channels to the tiles, as marked in Section 1. C B C C E = = B Mark 'D' from the inside of the wall channel to the edge of the inline panel. Dimension 'D' is the width of the panel. D Drill a 3mm hole each side for tray fitting. Size of holes for wet room fitting is dependent on floor specification. Installer to supply drill and plugs. = Mark 'E' from the tiles to the edge of the bonded panel. Dimension 'E' is 'A' minus 7mm, then minus the width of the bonded panel. = When fitting to a tray visually check that threshold is parallel to edge of tray. 1 Place the threshold centrally between 'D' and 'E'. 1 REMOVE THE THRESHOLD Screw the channel guides to tray or floor Mark second guide position. Screw the channel guides to the tray or floor Dimensions 'C', 'D' & 'E' Mark 'C' from the tiles to the inside edge of the threshold. Dimension 'C' is 'B' minus 7mm. A F F B minus 40mm B A minus 13mm 6mm 22 CFI365C 90° Drill 3mm holes for tray fitting. Size of holes for wet room fitting is dependent on floor specification. Installer to supply drill and plugs. Proceed to Section 4 Proceed to Section 4 2 2 CFI365C 19 SECTION 3 • FITTING THE CHANNEL GUIDES SECTION 3 • FITTING THE CHANNEL GUIDES ENCLOSURES WITH HINGES FITTED TO WALL DOOR ONLY WITH HINGES FITTED TO THE WALL Mark guide position by laying the threshold on the tray or floor Mark guide position. Dimensions 'A' & 'B' are the measurements from the outside edges of the wall channel and of the ‘U’ section wall channel template to the tiles, as marked in Section 1. DO NOT FIX IN PLACE 360 90o Using a fine toothed hacksaw cut the threshold to the width of the door glass plus 30mm. Cut the wall end at 90o to the threshold. Width of door plus 30mm The inside edge of the threshold should be 7mm back from the mark made for the wall channel in Section 1. A 362 = = = B minus 40mm B 362 = A minus 13mm 7mm When fitting to a tray visually check that the threshold is parallel to edge of tray. Drill a hole 6mm in from the end of the threshold. Drill 3mm for tray fitting. Size of hole for wet room fitting is dependent on floor specification. Installer to supply drill and plugs. 1 REMOVE THE THRESHOLD Screw the channel guide to tray or floor. Drill a 3mm hole for tray fitting. Size of hole for wet room fitting is dependent on floor specification. Installer to supply drill and plug. 1 Screw the channel guide to tray or floor F F 6mm 90° 20 CFI365C Proceed to Section 4 Proceed to Section 4 2 2 CFI365C 21
Similar documents
Iana 146 Sliding Door
• Regular cleaning is required to remove the small amounts of residue that are not repelled by the Protector
More information