Scroll comprESSorS
Transcription
Scroll comprESSorS
r410a // hermetic Scroll compressors orbit Series: Variable Speed Drive VSD Operation 60 Hz // ESP-133-2 ORBIT for variable speed drive (VSD) While the scroll compressors of the ORBIT series are characterized by high full load and seasonal efficiency, low sound levels, and high reliability, they are also now suitable for use with variable speed drives. VSD capable scroll compressors from BITZER give system designers more solutions to the challenge of maintaining full load and rating point efficiency levels, while also increasing efficiency at part load conditions where equipment operates during most of the year. Using the overspeed potential of the GSD gives the option of downsizing the nominal compressor displacement to cover partly the VSD costs. The wide speed range allows for capacity reduction together with low condensing pressure operation, e. g. in comfort air-conditioning applications, for high system efficiencies. Coupled with BITZER’s unique lower con densing temperature optimization, system designers have never had so many options to satisfy their customers’ needs. M 3~ I T1 T3 T5 U V W U ZK T4 T6 T2 Wide speed/capacity range 50 55 45 60 65 40 70 35 75 80 30 Hz The ORBIT with VSD capability provides smooth and efficient operation from 35 to 75 Hz*. While many designers use tandem and trio compounds to achieve simple and efficient capacity staging in chiller applications, the VSD capability of the ORBIT provides new options for refrigerant-to-air systems which need fast and instant capacity adaptation. The quick response of the ORBIT with VSD allows accurate temperature control. Design flexibility with reduced inventory costs Since standard ORBIT compressors are VSD capable, system designers have many options. Even tandems, uneven tandems, and even fixed + variable speed tandems, for example. And, when used with BITZER Advanced Header Technology, it is possible in many cases to offer different efficiency versions of the system with common piping and construction, which greatly reduces factory complexity and inventory carrying costs. Such technical solutions provide benefits for sales, technology, manufacturing and financial functions. * GSD6, GSD80421 & GSD80485: 45 to 65 Hz 2 ESP-133-2 Capacity (Tons according to ARI 540) 50 High cooling capacity The large capacity range of the ORBIT series is enhanced with the ability to either slow down, or speed up depending on demand. This increased range can allow users the option to reduce the number, size and variety of compressors used in the system design. 40 ORBIT 8 Nominal Speed G SD 80 42 G SD 80 G SD 80 G SD 80 23 G SD 80 G SD 80 18 2V 40 5V 10 29 5V 38 5V 1V 20 48 5V 30 ORBIT 8 Variable Speed Heat Pump Capacity & Heat Load: Fixed vs. Variable Speed Heat pump application Heat Pump Capacity [Btu/h] The ORBIT with VSD capability is an ideal solution for designers looking for high system performance. While a standard scroll compressor must cycle on /off to achieve temperature control in the building, a scroll with VSD can easily follow the characteristics. In addition, BITZER provides a large application envelope precisely in the area most needed by heat pump applications. Offsetting low refrigerant mass flow rates associated with these conditions is now possible with BITZER’s ORBIT with VSD capability. Supplemental Heat required Bivalent Point Ambient Temperature [°F] Required building heat Load Standard Scroll Compressor at fixed speed ORBIT 8 Variable Speed (smaller size compressor) Bivalent Point:Heating capacity of smaller size compressor at 75 Hz equal to standard scroll at fixed speed (50 Hz) IPLV for Refrigerant-to-Air Systems IPLV advantage Variable Speed BITZER ORBIT 20 15 ESP-133-2 Seasonal +15% Energy Efficiency Btu/(W x h) 25 While ORBIT operation is known for its optimization towards IPLV, these benefits are further enhances with the application of VSD technology increasing the IPLV even up to 15%. Designers can take advantage of the lower condensing pressures associated with part-load operation and further reduce their power consumption. This is in particular of advantage with refrigerant-to-air systems but also for chillers with two or more compressors in multi-circuits (one with VSD) for stepless modulation of the required cooling demand. 3 Application Limits BITZER ORBIT with VSD 35 Hz* Application after consultation with BITZER * GSD80182 .. GSD80385 only BITZER ORBIT 8 Boreal with VSD 160 SDT [°F] 140 35 Hz 120 100 80 SH = 20°F 60 -20 SST Saturated suction tempeature (°F) 4 0 20 SH Suction superheat (°F) 40 SST [°F] 60 SDT Saturated discharge temperature (°F) ESP-133-2 ORBIT 6 Performance data Performance data are based on ARI 540 boundary conditions. Saturated suction and discharge temperatures correspond to “dew point” conditions (saturated vapor). Performance data based on 20°F suction superheat and 15°F subcooling ➀. Cooling capacity Compressor type SST (°F) Qo Power consumption [kBTU] Ü GSD60137VA GSD60154VA GSD60182VA [kW] ➁ Energy Efficiency Ratio EER 45 45 45 SDT (°F) 130 Frequency (Hz) 45 65 100 45 60 65 164233 60 65 120 45 R410A ➂ GSD60120VA Pe 60 ORBIT 6 Q 92610 124000 134333 99810 133500 144625 112680 151600 P 8,15 10,85 11,76 7,27 9,71 10,52 5,84 7,81 8,46 EER 11,36 11,43 11,43 13,73 13,74 13,74 19,30 19,40 19,40 Q 103860 138000 149500 111870 150000 162500 126540 169700 183842 P 9,13 12,12 13,13 8,16 10,87 11,78 6,58 8,78 9,51 EER 11,37 11,39 11,39 13,72 13,79 13,79 19,22 19,33 19,33 Q 116550 154800 167700 125550 166200 180050 142020 188000 203667 P 10,20 13,52 14,65 9,11 12,10 13,11 7,36 9,81 10,63 EER 11,43 11,45 11,45 13,78 13,73 13,73 19,30 19,16 19,16 Q 137790 183700 199008 147870 197800 214283 167130 223300 241908 P 11,97 15,95 17,28 10,72 14,39 15,58 8,65 11,78 12,76 EER 11,51 11,51 11,51 13,80 13,75 13,75 19,32 18,96 18,96 Qo GSD60235VA P upon request COP Tentative data ➀ Running-in period 72 hours. ➁ Power consumption at motor terminals; power consumption at inverter intake depends on the individually applied inverter model. ESP-133-2 5 ORBIT 8 Performance data Performance data are based on ARI 540 conditions. Saturated suction and discharge temperatures correspond to “dew point” conditions (saturated vapor). Performance data based on 20°F suction superheat and 15°F subcooling ➀. Cooling capacity Compressor type SST (°F) GSD80295VA GSD80385VA GSD80421VA GSD80485VA Pe [kW] ➁ Energy Efficiency Ratio EER 45 45 45 45 45 45 45 45 45 130 60 130 75 (65) 120 35 120 60 120 75 (65) 100 35 100 60 100 75 (65) Q 86 181 213 96 194 230 115 220 263 P 9.4 16.7 20.0 8.0 14.9 17.8 5.8 11.9 14.2 EER 9.1 10.8 10.6 12.0 13.1 12.9 19.8 18.4 18.4 Q 118 238 285 132 257 307 157 293 350 P 13.4 22.9 27.2 11.4 20.1 24.2 8.3 15.6 19.4 EER 8.8 10.4 10.5 11.5 12.8 12.7 19.0 18.8 18.1 Q 152 297 362 170 322 392 203 368 448 P 17.5 28.2 34.9 14.9 24.8 30.9 10.8 19.3 24.5 EER 8.7 10.5 10.4 11.5 13.0 12.7 18.8 19.1 18.3 Q 204 386 474 225 417 510 262 474 578 P 21.4 35.5 43.9 18.3 31.4 39.3 13.6 24.9 31.8 EER 9.5 10.9 10.8 12.3 13.3 13.0 19.2 19.0 18.2 Q 221 419 446 245 453 481 288 517 549 P 23.5 38.9 20.0 34.4 27.1 9.4 10.8 12.3 13.2 36.3 ➂ 13.3 14.9 EER 40.8 ➂ 10.9 19.4 19.1 28.9 ➂ 19.0 Q 251 473 504 282 513 545 331 586 622 P 27.2 44.2 23.0 39.0 30.8 9.2 10.7 12.3 13.1 41.5 ➂ 13.1 16.9 EER 46.8 ➂ 10.8 19.7 19.0 33.1 ➂ 18.8 Ü GSD80235VA Power consumption [kBTU] SDT (°F) 130 Frequency (Hz) 35 R410A ➂ GSD80182VA Qo ORBIT 8 optimized for air-cooled systems and reversible chillers ORBIT 8 Boreal optimized for systems with low condensing temperature SST (°F) GSD80235VW GSD80295VW GSD80385VW GSD80421VW GSD80485VW Ü Compressor type 45 45 45 45 45 45 SDT (°F) 115 Frequency (Hz) 35 115 60 115 75 (65) 80 35 80 60 80 75 (65) Q 144 275 318 186 339 395 P 11.0 19.1 23.2 5.8 11.6 14.4 EER 13.0 14.4 13.7 31.9 29.2 27.3 Q 181 332 400 233 410 495 P 13.7 23.2 29.1 7.3 13.8 18.1 EER 13.1 14.3 13.8 32.1 29.7 27.4 Q 227 482 516 295 594 635 P 17.6 34.8 37.9 9.5 21.8 24.1 EER 12.9 13.8 13.6 31.0 27.3 26.4 Q 249 467 494 328 580 615 P 19.0 32.7 10.3 20.1 EER 13.1 14.3 34.7 ➂ 14.2 31.7 28.8 21.5 ➂ 28.5 Q 286 534 562 380 668 706 P 21.3 37.3 11.6 23.0 EER 13.4 14.3 39.4 ➂ 14.3 32.7 29.0 24.6 ➂ 28.7 Tentative data ➀ Running-in period 72 hours. ➁ Power consumption at motor terminals; power consumption at inverter intake depends on the individually applied inverter model. ➂ Performance data at 65 Hz. 6 ESP-133-2 ORBIT 6 Technical data ➀ Oil charge fl.oz 10.6 .. 15.3 45 .. 65 Hz 91 Pipe connections ODS DL Discharge line SL Suction line lbs inch inch 195 7/8 1 1 3/8 ➁ CFM GSD60120VA Weight Electrical data compressor Rated load Starting Motor amps current connection (RLA) LRA (Amp.) ➂ Amp. ➃ 3/8 GSD60137VA 11.9 .. 17.1 45 .. 65 Hz 91 195 7/8 GSD60154VA 13.2 .. 19.1 45 .. 65 Hz 91 195 7/8 1 3/8 GSD60182VA 15.6 .. 22.5 45 .. 65 Hz 91 195 7/8 1 3/8 GSD60235VA 26.7 60 Hz 91 195 7/8 1 3/8 Amp. ➄ See BITZER Software Speed range See BITZER Software Displacement with 45 .. 65 Hz Contact BITZER Compressor type ➀ Preliminary data. Speed range at time of publication. These data are subject to change as a result of BITZER’s policy of continuous improvement. Contact your local BITZER representative for application assistance. ➁ Charged with polyvinyl ether BVC32. ➂ Motor selection for FI operation depends on application considerations. For full envelope and over-speed capability, selection of the 208/230 V motor is generally required. Less demanding applications focused on IPLV consideration may be handled by either standard motor, or 380 V motors. Contact BITZER for assistance in proper selection. ➃ For the selection of contactors, cables and fuses the rated load amps (RLA) and the max. power consumption must be considered (“Electrical data”). RLA (MCC/1.56). ➄ Data for direct start. With VSD stepless rise of current up to actual load amps – maximum up to rated load amps (RLA). Oil heater (option) 90 W/115 V, 230 V, 460 V, 575 V. For dimensional drawings see brochure ESP-125. ESP-133-2 7 ORBIT 8 Technical data Compressor type Displacement with 35 .. (65) 75 Hz Speed range Oil charge ➀ fl.oz CFM Weight Pipe connections ODS Version “B” ➁ DL SL Discharge Suction line line lbs Connection thread Version “R” ➁ DL SL Discharge line Suction line inch inch inch inch Electrical data compressor Rated Starting Motor current connec- load amps LRA tion (RLA) (Amp.) ➂ Amp. ➃ Amp. ➄ 320 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF GSD80235VA(B/R)2 16 .. 34 35 .. 75 Hz 179 326 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF GSD80295VA(B/R)2 20 .. 43 35 .. 75 Hz 179 333 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF GSD80385VA(B/R)2 26 .. 55 35 .. 75 Hz 179 337 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF GSD80421VA(B/R)2 28 .. 52 35 .. 65 Hz 179 336 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF GSD80485VA(B/R)2 32 .. 60 35 .. 65 Hz 179 372 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF See BITZER Software 179 See BITZER Software 35 .. 75 Hz See BITZER Software 12 .. 26 Contact BITZER GSD80182VA(B/R)2 Contact BITZER ORBIT 8 optimized for air-cooled systems and reversible chillers GSD80235VW(B/R)2 16 .. 34 35 .. 75 Hz 179 326 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF GSD80295VW(B/R)2 20 .. 43 35 .. 75 Hz 179 333 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF GSD80385VW(B/R)2 26 .. 55 35 .. 75 Hz 179 337 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF GSD80421VW(B/R)2 28 .. 52 35 .. 65 Hz 179 336 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF GSD80485VW(B/R)2 32 .. 60 35 .. 65 Hz 179 338 1 3/8 1 5/8 1 3/4 – 12 UNF 2 1/4 – 12 UNF See BITZER Software ORBIT 8 Boreal optimized for systems with low condensing temperature ➀ Charged with polyvinyl ether BVC32. ➁ B = Direct brazing connections, R = Rotalock connections. ➂ Motor selection for FI operation depends on application considerations. For full envelope and over-speed capability, selection of the 208/230 V motor is generally required. Less demanding applications focused on IPLV consideration may be handled by either standard motor, or 380 V motors. Contact BITZER for assistance in proper selection. ➃ For the selection of inverter. ➄ Data for direct start. With VSD stepless rise of current up to actual load amps – maximum up to rated load amps (RLA). GSD80182V .. GSD80485V: Oil heater (option) 140 W/115 V, 230 V, 460 V, 575 V. For dimensional drawings see brochure ESP-135. 8 ESP-133-2 Notes ESP-133-2 9 Notes 10 ESP-133-2 Notes ESP-133-2 11 B itze r Kühlmaschinenbau GmbH Eschenbrünnlestr aße 15 // 71065 Sindelfingen // Germany Tel +49 (0)70 31 932-0 // Fa x +49 (0)70 31 932-147 bitzer@bitzer.de // w w w.bitzer.de Subject to change // 80171202 // 12.2014