Digital Fiberoptic Sensor
Transcription
Digital Fiberoptic Sensor
NEW Digital Fiberoptic Sensor FS-N Series I n a d d i t i o n to i t s M EG A p owe r, t h e FS - N S e r i e s i n t r o d u c e s u n p r e c e d e n te d s e t u p e a s e with one click operation. NEO-MEGA ONE CLICK PRESET DATUM Certainty and simplicity There are two major qualities that are important in fiber sensors. First, the sensor must have improved basic performance, including ample beam power and accuracy, for greater detection stability. Second, the sensor must be easy for anyone to setup and operate. Instant alarm readout! 2 NEO-MEGA ONE CLICK PRESET DATUM New Concept Complete setting in just one click O N E C L I C K PR E S E T An entirely new concept in setup ease. Just one click calibrates the sensitivity and resets the display. New Concept Automatic maintenance DAT U M The sensor automatically detects reduced light intensity due to debris build-up and automatically re-calibrates to the original display state. Simple, Convenient High power reduces labor hours NEO-MEGA Increased sensor power greatly reduces maintenance and setup time. NEO is supported by the world's highest level of performance World’s most powerful beam 250 Achieves times more light intensity World’s most accurate World’s highest ambient-light resistance Detects wire as small as Unaffected up to ø0.6 µm (0.024 mil) 30,000 lux 3 New Concept Complete setting in just one click Click the button once to simultaneously set the sensitivity and reset the display value to 100. What customers are saying “ I usually just set the sensitivity. It would be nice if I could reset all of the settings and current values, but I wouldn't use this feature if it's complicated. ” CLICK! PRESET button “ With the NEO, just one click All values reset to sets the sensitivity and 100 resets the display! 4 ” ONE CLICK PRESET Carefree setup Point 1 DATUM NEO-MEGA Automatic maintenance Harnessing power Easy to detect changes (preventive maintenance) The NEO provides an easy-to-read indication when the light intensity drops due to dirt or other environment related causes. Conventional problem FS-NEO Light intensity reduction is difficult to grasp due to individual differences in numeric values. All sensors initially display 100, making it easy to detect changes. ? Failure! Point 2 Easy to tell the value has changed Failure! The digital value resets to exactly 100 Conventional problem FS-NEO The value easily shifted and the initial value of 2000 was arbitrary. The numbers reset to exactly 100. The set values are reset to 50. Never reaches exactly 2000 Set ting the value to an easier to read value of 1000 required a complicated operation. T h e a b i l i t y to c h a n g e th e t a rg et va l u e m a d e i t d i f f i c u l t to ke e p tr a c k of th e o r i g i n a l va l u e. Set value reset to 50 Display value reset to exactly 100 Resetting numeric values with one click offers unprecedented operating ease. CLICK! Point 3 Greater convenience when using multiple sensors If the light intensity drops PRESET button Correction required Light intensity drop The preset function is even more useful when using multiple sensors. Quickly and easily locate sensors that have become dirty or misaligned. Main and expansion unit sensors can be reset with one click by pressing PRESET on the main unit. Pressing PRESET resets to the initial state. If the light intensity drops significantly it will not return to 100.0, making it easy to detect the problem. The 2-output type can be used to provide a low light intensity signal to a PLC or similar controller. Digital Fiber Sensor FS-N Series > Feature 1 5 ONE CLICK PRESET DATUM Carefree setup Automatic maintenance NEO-MEGA Harnessing power New Concept Automatic maintenance The automatic maintenance function detects light intensity reduction due to dirt or misalignment, and returns the sensor to its original display state. This feature can cancel the effects of the ambient environment, enabling the sensor to continue to perform highly accurate detections. Automatically recovers by canceling the effects of the ambient environment. Drop due to dirt build-up Auto Maintenance! Original display state Light intensity drop due to an ambient environment Problem-free environment Automatic maintenance function: DATUM DATUM: ON The setting value changes according to the Light Intensity Light Intensity intensity as shown in the figure to the right. This function corrects the setting value DATUM: ON Light Intensity 100.0 DATUM: ON based on a running average of the received light intensity value. The correction cycle is the same as the sampling cycle and can be Threshold Light Intensity 50.0 selected from three levels. Light Intensity Threshold 6 Digital Fiber Sensor FS-N Series > Feature 2 ONE CLICK PRESET DATUM NEO-MEGA Automatic maintenance Carefree setup Harnessing power Simple, Convenient World’s highest power reduces maintenance time "High power" = "large excess gain" that not only reduces the need for maintenance but also expands sensor head capabilities, which reduces setup time. 1 Switch selectable MEGA power Power selector switch Hassle-free operation allows easy changeover between standard and high power. SLIDE! Long distance [MEGA] 3 Prevent light saturation with a simple operation Strong light may result in reduced contrast. In Short distance [FINE] this case, simply press the “MODE” + “SET” buttons to automatically adjust the NEO to the proper light intensity. Target present No target Light saturation Target present No target Detecting the seam between transparent fi lms 2 Reduced light intensity variations Circular reflector With conventional models, amplifying the projected beam of condensed light causes the focus of the beam to be sensitive to minute positioning errors in the light-emitting device. The NEO-LED solves LED chip that equally emits light from its entire surface Custom LED emits concentrated intensity only from the top surface. Conventional LED NEO-LED this positioning problem by using a reflector around the light emitting source. The reflector reduces light intensity variations. The circular reflector helps compensate for light positioning errors by redirecting any stray light back into the fiber. World's most powerful beam: NEO-MEGA Guideline for received light intensity 250 times greater than conventional models NEO-MEGA, the world's most powerful beam, allows for signifi cant improvement of repeatability and hysteresis. Conventional standard*1 The emitted light intensity is about 4 times stronger than conventional models. *1. FS-V30 Series in FINE mode 0 Hysteresis characteristics (Typical) FS-N Series FS-N Series Conventional Model* 2 Conventional Model* 2 50 1.97" 100 3.94" Distance Hysteresis NEO-MEGA Repeatability Repeatability (Typical) 150 mm 5.91" inch 0 50 1.97" 100 3.94" 150 mm 5.91" inch Distance *2. FS-V30 Series Digital Fiber Sensor FS-N Series > Feature 3 7 Convenient functionality designed for ease of use in the field Using the external calibration input* Wire saving when adding sensors PLC The sensor can be calibrated from a PLC or other external device. Regularly executing the Preset function from an external input ensures uninterrupted, stable detection, even in harsh environments. The 2-output type can be used to provide a low light intensity signal if the sensor becomes When adding sensors, the power is supplied from the connector on the side. This reduces wiring by two cables per sensor, allowing for a neater, quicker installation. Note: Only supports FS-N Series amplifiers. extremely dirty. * Available on models with external input support. Easy sensitivity setting (two-point tuning) CLICK! CLICK! Reliable even when using multiple sensors All models equipped with a standard heat sink. The heat sink reduces the temperature of the amplifier, and reduces the stress on the LED light source as well as other internal parts. Zero Shift Setting the current value to "0" just got easier. Simply press the PRESET and RIGHT button at the same time. CLICK! CLICK! Set by simply pressing the SET button once with the target present, and once without it. Using a NEO amplifier with an external input, the Zero Shift adjustment can be performed on a regular basis using a PLC or other external device. No target Network support COMING SOON KEYENCE engineers are currently developing a communication unit that will connect the FS-NEO directly to an open field network. This will provide easy read and write access for various settings. 8 Digital Fiber Sensor FS-N Series > Other Features Complete lineup Cable Type Model Type NPN output PNP output Main unit FS-N11N FS-N11P Expansion unit FS-N12N FS-N12P Main unit FS-N13N FS-N13P Main unit Standard Control outputs External input Analog output 1 0 2 1 0 0 2-output Expansion unit Expansion unit FS-N14N FS-N14P Main unit FS-N11MN — 1 NPN output PNP output Control outputs Main unit FS-N11CN FS-N11CP Expansion unit FS-N12CN FS-N12CP Main unit — FS-N13CP Expansion unit — FS-N14CP Analog Connector Type (M8) Model Type Main unit Standard 1 1 External input Analog output 1 0 Expansion unit 2-output 2 0 Optional (sold separately) Model Description Amplifier securing bracket (for main unit) Can be installed without a DIN-rail. Can be installed from above or from the side. OP-73880 Used to secure the main and expansion units. (Two per set) OP-26751 (Two per set) OP-73880 End unit (when using expansion units) M8 connector cable (2 m (6.56')/10 m (32.81')) OP-26751 2 m (6.56') type OP-73864 Used to connect to the M8 connector type amplifier (model numbers end with a “CN” or “CP”). Connector cables are not included with the amplifier. 10 m (32.81') type OP-73865 Digital Fiber Sensor FS-N Series > Lineup 9 Fiber Unit FU Series Fiber Unit [ F U S e r i es ] Choose from our selection of more than 100 types of fiber units. S t a n d a r d Ty p e S t a n d a r d Ty p e Integrated Bracket Flat The sensor is integrated into an L-shaped bracket, which simplifies installation. This thin profile sensor comes with mounting holes for installation where space is limited. P.13 P.13 S t a n d a r d Ty p e S t a n d a r d Ty p e Threaded and Hex-shaped Fibers Set screw Small size is suitable for installation in locations where space is limited. Installed by drilling a hole and using a set screw. Threaded for easy mounting onto brackets and machine equipment. P.14 P.16 S t a n d a r d Ty p e F o c u s e d B e a m Ty p e Sleeve Small Spot Reflective The fiber tip is a thin sleeve. Eliminate problems caused by limited mounting space. Lineup includes side-view and bendable sleeve types. Ideal for detecting small objects. Spot size and focal distance are adjustable, so there is no need to change the distance between the sensor and the target. P.17 P.18 H i g h - p o w e r B e a m Ty p e P.19 10 Cylinder H i g h - p o w e r B e a m Ty p e Area Retro-reflective This sensor forms a wide-area beam, making it ideal for movingtarget applications, such as detection of falling objects. The use of a reflector in place of the receiver used with thrubeam sensors simplifies installation and optical axis alignment. This sensor is suitable for detecting transparent objects. P.19 H i g h - p o w e r B e a m Ty p e P.20 F i x e d R a n g e Ty p e Narrow Beam/High-power Definite-reflective Narrow field of view based on focused aperture angle. This sensor reduces stray light for stable target detection. The high-power reflective type with an 8° aperture angle is suitable for detecting objects at longer distances. Detects within a fi xed distance. Reduces the effect of background, and features a space-saving thinprofile design. High-flex P.20 O i l /C h e m i c a l R e s i s t a n t High-flex* Oil/Chemical Resistant The R2 (R0.08") ToughFlex fiber achieves excellent flexing characteristics with the same bend radius. * 10 million bends The PTFE coating allows these fibers to be used in almost any environment, including oil- or chemical-splash conditions. P.21 P.21 Heat Resistant A p p l i c a t i o n - s p e c i f i c Ty p e Heat Resistant Liquid-level Ideal for use in high temperature applications. Withstands temperatures up to 350°C (662°F). Detects liquid levels when immersed or attached to a transparent tube. P.22 P.23 A p p l i c a t i o n - s p e c i f i c Ty p e Liquid Cr ystal/ Semiconductors Perfect for glass substrate detection. Lineup offers distance alignment, edge detection, and wafer mapping types. P.23 Digital Fiber Sensor FS-N Series > Fiber Unit > Line-up 11 Model search Model FU- 10 Page P.18 FU- 11 Model Page FU- 48U P.21 FU- 49X P.19 FU- 77V P.16, 21 FU- 5F FU- 13 FU- 5FZ FU- 16 FU- 50 FU- 16Z P.20 FU- 79 P.21 FU- 79U P.20 FU- 51TZ FU- 81C FU- 82C FU- 52TZ FU- 18 FU- 83C P.13 P.20, 23 FU- 53TZ FU- 84C FU- 20 P.18 FU- 54TZ FU- 85A FU- 21X P.15 FU- 55 P.16 FU- 85H FU- 22X P.16, 17 FU- 56 P.16, 17 FU- 85Z FU- 23X P.16 FU- 57TE P.21 FU- 86A FU- 18M P.22 FU- 57TZ P.13 FU- 86H FU- 25 FU- 58 P.16 FU- 86Z FU- 31 FU- 58U P.21 FU- 87 FU- 32 FU- 59 P.16, 21 FU- 87K FU- 33 FU- 59U P.21 FU- 88 FU- 34 FU- 6F FU- 35FA FU- 61 FU- 35FG FU- 61Z FU- 92 FU- 63 FU- 93 FU- 24X P.15 P.17 FU- 35FZ P.15 P.14 FU- 78 P.16 FU- 15 Page FU- 77TZ FU- 49U FU- 12 Model FU- 88K P.15 FU- 91 P.21 FU- 35TG FU- 63T FU- 35TZ FU- 63Z FU- 93Z FU- 95 FU- 65X FU- 95HA FU- 66 FU- 95S FU- 66TZ FU- 95W FU- 66Z FU- 95Z P.17 FU- 37 P.20 FU- 38 FU- 38H P.23 P.22, 23 FU- 38K FU- 38L P.23 FU- 67 FU- 38LK P.22, 23 FU- 67G FU- A05 FU- 67TG FU- A05D FU- 67TZ FU- A10 FU- 67V FU- A10D FU- 68 FU- E11 FU- 38R FU- 96 P.15 P.21 P.23 FU- 38S FU- 38V P.20, 23 FU- 4F P.19 P.16 FU- 4FZ FU- 69U FU- 40 FU- 69X P.20 FU- 40G FU- 40S P.23 FU- 41TZ P.21 FU- L50Z FU- 7F P.14 FU- L51Z FU- 70U P.21 FU- L52Z FU- 71 P.13 FU- 42TZ P.14 FU- 43 P.17 FU- 73 FU- 44TZ P.13 FU- 75F FU- L54Z FU- L41Z P.17 FU- 76F P.16, 17 FU- 46 P.13 FU- L53Z FU- 71Z FU- 45X FU- E40 FU- 77 FU- 47TZ P.13 FU- 77G FU- 48 P.16, 21 FU- 77TG 12 Digital Fiber Sensor FS-N Series > Fiber Unit > Index P.14 Fibre Unit FU Series Inte grate d B rac ket Integrated bracket and sensor simplifi es installation. Thrubeam/reflective types Detecting method Type Fiber unit length (Diameter) Beam emitting Optical axis Ambient direction height (mm inch) temperature 10 0.39" Appearance (mm inch) Detecting distance (mm inch)*1 Minimum bend radius (mm inch) MEGA FINE Other power modes Optical axis diameter (mm inch) (Standard target to be detected) 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to + 50˚C -40 to + 122˚F 0.48" 12.2 FU-L51Z Approx. 30 g 12.2 17 0.67" 0.48" 2−ø3.4 ø0.13" Top Thrubeam 15 0.59" 20 0.79" Reflective Top (lens) 10 0.39" Side 10 0.39" Top 10 0.39" 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to + 50˚C 0.67" -40 to + 122˚F 17 12.2 17 0.67" 0.48" 2−ø3.4 ø0.13" 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to + 50˚C -40 to + 122˚F 22 0.87" 12.2 17 0.67" 0.48" 2−ø3.4 ø0.13" 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to + 50˚C -40 to + 122˚F 0.51" 13 MEGA: 2200 FINE: 450 86.61" 17.72" ULTRA: 1700 SUPER: 1000 TURBO: 760 HSP: 290 66.93" 39.37" 29.92" 11.42" ø1.13 ø0.04" 2−ø3.4 ø0.13" R2 R0.08" ToughFlex FU-L52Z Approx. 30 g FU-L53Z R2 R0.08" ToughFlex 14 20 0.79" 0.55" 2−ø3.4 ø0.13" 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to + 50˚C -40 to + 122˚F 12.8 0.50" 0.67"17 12.8 0.50" 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to + 50˚C -40 to + 122˚F 0.51" 13 2−ø3.4 ø0.13" 17 0.67" 0.55" 14 Model Weight Approx. 30 g MEGA: 3600 141.73" FINE: 3100 122.05" ULTRA: SUPER: TURBO: HSP: MEGA: 1900 FINE: 410 ULTRA: 1500 SUPER: 900 TURBO: 700 HSP: 270 59.06" 35.43" 27.56" 10.63" ø1.13 ø0.04" ULTRA: SUPER: TURBO: HSP: 22.83" 16.93" 12.60" 3.54" − 74.80" 16.14" MEGA: 760 29.92" FINE: 170 6.69" 3600 141.73" 3600 141.73" 3600 141.73" 2100 82.68" 580 430 320 90 ø3.5 ø0.14" FU-L50Z Approx. 30 g FU-L54Z Approx. 30 g FU-L41Z Approx. 25 g *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. Mount directly in locations where space is limited. Flat Thrubeam/reflective types Type Detecting method Beam emitting direction Fiber unit length (Diameter) Ambient temperature Appearance (mm inch) 1 m 3.28' Free-cut (ø1.0 ø0.04") -40 to +50˚C 0.39"10 -40 to +122˚F 10 0.39" Thickness: 3 0.12" 2 m 6.56' Free-cut (ø1.3 ø0.05") 0.55" -40 to +50˚C 14 -40 to +122˚F 2−ø3.2 ø0.13" Thrubeam Side Flat Top Side 14 0.55" Thickness: 3.5 0.14" 1 m 3.28' Free-cut (ø1.0 ø0.04") -40 to +50˚C 10.5 0.41" -40 to +122˚F ø0.08" 2−ø2.1 0.24" 6 Thickness: 2.5 0.10" 1 m 3.28' Free-cut (ø1.0 ø0.04") -40 to +50˚C 0.28" 7 ø0.08" -40 to +122˚F 2−ø2.1 0.51" 13 Thickness: 8 0.32" 2 0.08" 1 m 3.28' Free-cut (ø1.0 ø0.04" x 2) -40 to +50˚C -40 to +122˚F 10.5 0.41" 2−ø2.1 ø0.08" R2 R0.08" ToughFlex 2−ø2.1 ø0.08" Thickness: 7 0.28" 2 0.08" 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +50˚C -40 to +122˚F 0.51" 13 Flat 0.79" 20 Other power modes 810 170 31.89" 6.69" MEGA: 2900 FINE: 610 114.17" 24.02" ULTRA: SUPER: TURBO: HSP: Optical axis diameter (mm inch) (Standard target to be detected) 520 340 260 90 20.47" 13.39" 10.24" 3.54" ø0.5 ø0.02" ULTRA: 1900 SUPER: 1200 TURBO: 850 HSP: 260 74.80" 47.24" 33.46" 10.24" ø1 ø0.04" MEGA: FINE: 740 140 29.13" 5.51" ULTRA: SUPER: TURBO: HSP: 480 280 200 70 18.90" 11.02" 7.87" 2.76" MEGA: FINE: 500 140 19.69" 5.51" ULTRA: SUPER: TURBO: HSP: 340 230 180 80 13.39" 9.06" 7.09" 3.15" MEGA: 2900 FINE: 610 114.17" 24.02" ULTRA: 1900 SUPER: 1200 TURBO: 850 HSP: 260 74.80" 47.24" 33.46" 10.24" Model Weight FU-51TZ Approx. 5 g FU-52TZ Approx. 15 g FU-57TZ Approx. 5 g ø0.5 ø0.02" Thickness: 4 0.16" 1 m 3.28' Free-cut (ø1.0 ø0.04" x 2) -40 to +50˚C -40 to +122˚F 2−ø2.1 ø0.08" 6.5 0.26" Thickness: 2.5 0.10" 1 m 3.28' Free-cut (ø1.0 ø0.04") -40 to +50˚C -40 to +122˚F Reflective R2 R0.08" ToughFlex Thickness: 2 0.08" 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to +50˚C 0.28" 7 -40 to +122˚F 2−M3 0.59" 15 0.28" 7.2 MEGA FINE MEGA: FINE: 2−ø2.1 ø0.08" Top Detecting distance (mm inch)*1 Minimum bend radius (mm inch) 2−ø3.2 ø0.13" Thickness: 7 0.28" 4 0.16" MEGA: 1 to 160 0.04" to 6.30" FINE: 1 to 36 0.04" to 1.42" ULTRA: 1 to 120 SUPER: 1 to 81 TURBO: 1 to 60 HSP: 1 to 13 0.04" to 4.72" 0.04" to 3.19" 0.04" to 2.36" 0.04" to 0.51" MEGA: 1 to 160 0.04" to 6.30" FINE: 1 to 36 0.04" to 1.42" ULTRA: 1 to 120 SUPER: 1 to 81 TURBO: 1 to 60 HSP: 1 to 18 0.04" to 4.72" 0.04" to 3.19" 0.04" to 2.36" 0.04" to 0.71" MEGA: 2 to 120 0.08" to 4.72" FINE: 2 to 24 0.08" to 0.94" ULTRA: SUPER: TURBO: HSP: 0.08" to 3.03" 0.08" to 1.97" 0.08" to 1.26" 0.08" to 0.32" MEGA: 1 to 500 0.04" to 19.69" FINE: 1 to 70 0.04" to 2.76" ULTRA: 1 to 320 0.04" to 12.60" SUPER: 1 to 190 0.04" to 7.48" TURBO: 1 to 130 0.04" to 5.12" HSP: 1 to 50 0.04" to 1.97" FU-53TZ Approx. 10 g ø1 ø0.04" FU-54TZ Approx. 25 g FU-44TZ Approx. 3 g FU-47TZ Approx. 4 g − 2 to 77 2 to 50 2 to 32 2 to 8 FU-41TZ Approx. 5 g FU-42TZ Approx. 24 g *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 13 Most common fi ber sensor. Easily mounts onto brackets or machine equipment. Threaded and Hex-shaped Fibers Thrubeam Type Detecting method Fiber unit length (Diameter) Ambient temperature Size/Shape Appearance (mm inch) MEGA FINE R2 R0.08" ToughFlex MEGA: 3100 122.05" FINE: 640 25.20" ULTRA: 2100 SUPER: 1300 TURBO: 880 HSP: 320 82.68" 51.18" 34.65" 12.60" MEGA: 1800 FINE: 640 70.87" 25.20" ULTRA: 1800 SUPER: 1300 TURBO: 880 HSP: 320 70.87" 51.18" 34.65" 12.60" MEGA: 3600 141.73" FINE: 880 34.65" ULTRA: 3000 SUPER: 1800 TURBO: 1300 HSP: 430 118.11" 70.87" 51.18" 16.93" 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to +50˚C 0.57" M4 -40 to +122˚F 14.4 Hex-shaped 1 m 3.28' cut not allowed. -40 to +50˚C 0.59" M4 -40 to +122˚F 15 R10 R0.39" Stainless Steel 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to +50˚C -40 to +122˚F M4 Threaded 14 0.55" 1 m 3.28' cut not allowed. -40 to +50˚C -40 to +122˚F M4 22 0.87" 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to +70˚C -40 to +158˚F M4 2 m 6.56' Free-cut (ø1.3 ø0.05") -40 to +70˚C -40 to +158˚F M4 R2 R0.08" ToughFlex 15 0.59" MEGA: 1800 FINE: 880 70.87" 34.65" FU-77TZ FU-77TG Approx. 43 g FU-77V ø1.13 ø0.04" Approx. 25 g FU-77 R4 R0.16" MEGA: 2200 FINE: 440 ULTRA: 1400 SUPER: 860 TURBO: 600 HSP: 220 R2 R0.07" ToughFlex MEGA: 3600 141.73" FINE: 1100 43.31" ULTRA: 3600 141.73" SUPER: 2300 90.55" TURBO: 1600 62.99" HSP: 590 23.23" R25 R0.98" MEGA: 3600 141.73" FINE: 1300 51.2" ULTRA: 3600 141.73" SUPER: 2600 90.55" TURBO: 1800 70.87" HSP: 650 25.59" 86.61" 17.32" 16 0.63" 55.12" 33.86" 23.62" 8.66" FU-77G Approx. 39 g FU-7F Approx. 21 g ø1 ø0.04" FU-78 Approx. 9 g FU-71Z Approx. 25 g ø1.5 ø0.06" FU-71 Approx. 25 g Thrubeam Lenses Type Ambient temperature Appearance (mm inch) Detecting distance (mm inch)*1 Model Weight Heat Resistance: 70°C 158°F Ultra-long detecting distance Narrow field of view Aperture Angle: Approx. 8° MEGA ULTRA SUPER TURBO FINE F-4 Approx. 1 g 3600 141.73" FU-7F ø0.16" Tip: ø4 F-2 Approx. 2 g 2200 86.61" 1800 70.87" FU-77TZ/77V/77/ 84C/88K 3600 141.73" 2100 82.68 FU-7F/86A 3600 141.73" 2500 98.43" FU-86Z 3600 141.73" 1900 74.80" 3600 141.73" FU-78 7.9 0.31" 3300 129.92" FU-7F/86A F-5 Approx. 10 g 9.3 0.37" 5.6 0.22" 2300 90.55" 1800 70.87" FU-77G ø0.16" Tip: ø4 FU-77G F-1 Approx. 2 g Side-view 9.5 3.74" 2900 114.17" FU-78 16.7 0.66" FU-77V/77 FU-7F/86A 3600 141.73" 3100 122.05" 1900 74.80" 1300 51.18" 900 35.43" 530 20.87" 1300 51.18" 900 35.43" 530 20.87" 3100 122.05" 2100 82.68" 1300 51.18" 630 24.80" 1800 70.87" 3600 141.73" FU-86Z 3600 141.73" 3300 129.92" 2300 90.55" 1500 59.06" 1100 43.31" 500 19.69" FU-78/84C/88K 3200 125.98" 2500 98.43" 1600 62.99" 1100 43.31" 800 31.50" 360 14.17" *1 The maximum sensing distance of 3600 mm 141.73" (1800 mm 70.87") is possible because the fiber length on each side is 2 m 6.56' (1 m 3.28'). *2 When using the F-1 at 70°C 158°F or more, specify the "Heat-resistant F-1".Be sure to use the "Heat-resistant F-1" at a constant temperature. 14 F-5 3100 122.05" 3600 141.73" FU-86Z Heat Resistance: 70°C 158°F*2 1600 62.99" 2600 102.36" FU-77V/77 Fixing Nut Side-view with mounting holes F-2 1800 70.87" FU-77G/77TG Heat Resistance: 105°C 221°F F-4 3200 125.98" FU-78 FU-77G/77TG Heat Resistance: 300°C 572°F HSP 2700 106.30" FU-77TZ/77V/77 ø0.17" Tip: ø4.3 9.5 0.37" Long-detecting distance Aperture Angle: Approx. 15° Applicable fiber units Model Weight Approx. 43 g 70.87" 70.87" 51.18" 16.93" ULTRA: 3200 125.98" SUPER: 2200 86.61" TURBO: 1500 59.06" HSP: 540 21.26" M6 Threaded ULTRA: 1800 SUPER: 1800 TURBO: 1300 HSP: 430 MEGA: 3600 141.73" FINE: 1100 43.31" R25 R0.98" 15 0.59" Optical axis diameter (mm inch) (Standard target to be detected) Approx. 21 g R10 R0.39" Stainless Steel 2 m 6.56' Free-cut (ø2.2 ø0.09") FU-71Z: -40 to +50˚C -40 to +122˚F FU-71: -40 to +70˚C -40 to +158˚F M6 Other power modes R0.5 R0.02" ToughFlex M4 Thrubeam Detecting distance (mm inch) Minimum bend radius (mm inch) F-1 Fibre Unit FU Series Reflective Type Detecting method Size/Shape Detecting arrangement Fiber unit length (Diameter) Ambient temperature 1 m 3.28' Free-cut (ø1.3 ø0.05 x 2) -40 to +50˚C -40 to +122˚F Hex-shaped Appearance (mm inch) 0.73" 18.5 R2 R0.08" ToughFlex 1 m 3.28' Free-cut (ø1.3 ø0.05 x 2) 0.67" 17 -40 to +50˚C -40 to +122˚F Model Weight Other power modes 15.75" 2.76" Lens attachment: P.18 ULTRA: SUPER: TURBO: HSP: 270 170 110 32 10.63" 6.69" 4.33" 1.26" ULTRA: SUPER: TURBO: HSP: 290 190 115 36 11.42" 7.48" 4.53" 1.42" FU-35TZ Approx. 7 g FU-35FZ 1 m 3.28' Free-cut (ø1.3 ø0.05 x 2) 0.71" 18 Spiral 30 cm -40 to +50˚C -40 to +122˚F M3 Threaded 400 70 MEGA: 450 FINE: 72 M3 Coaxial MEGA FINE MEGA: FINE: M3 M3 Detecting distance (mm inch)*1 Minimum bend radius (mm inch) R10 R0.39" Stainless Steel 1 m 3.28' Free-cut (ø1.3 ø0.05 x 2) 0.91" 23 -40 to +70˚C -40 to +158˚F 17.72" 2.76" M3 ULTRA: SUPER: TURBO: HSP: 400 250 160 45 15.75" 9.84" 6.30" 1.77" 50 cm 1.64' cut not allowed. FU-21X: -40 to +70˚C -40 to +158˚F FU-24X: -40 to +50°C -40 to +122˚F ULTRA: SUPER: TURBO: HSP: 90 54 40 23 3.54" 2.13" 1.57" 0.91" ULTRA: SUPER: TURBO: HSP: 72 32 23 8 2.83" 1.26" 0.91" 0.32" 25.2" 5.51" ULTRA: SUPER: TURBO: HSP: 420 320 220 70 16.54" 12.60" 8.66" 2.76" 770 30.32" 190 7.48" ULTRA: SUPER: TURBO: HSP: 560 380 260 80 22.05" 14.96" 10.24" 3.15" MEGA: 1100 43.31" FINE: 300 11.81" ULTRA: SUPER: TURBO: HSP: 860 570 410 140 33.86" 22.44" 16.14" 5.51" MEGA: FINE: ULTRA: SUPER: TURBO: HSP: 550 470 310 90 21.65" 18.50" 12.20" 3.54" Lens attachment: P.18 FU-35FG Approx. 15 g Lens attachment: P.18 MEGA: 550 21.65" FINE: 110 4.33" Approx. 6 g FU-35FA Approx. 6 g R25 R0.98" MEGA: FINE: 130 36 5.12" 1.42" Lens attachment: P.18 FU-21X Approx. 4 g 0.59" 15 M3 R10 R0.39" MEGA: 100 FINE: 13 3.94" 0.51" Lens attachment: P.18 2 m 6.56' Free-cut (ø1.3 ø0.05 x 2) 0.53"13.5 -40 to +50˚C -40 to +122˚F Hex-shaped MEGA: 640 FINE: 140 M4 2 m 6.56' Free-cut (ø1.3 ø0.05 x 2) FU-66Z: -40 to +50°C -40 to +122˚F FU-66: -40 to +70˚C -40 to +158˚F M4 Threaded R2 R0.08" ToughFlex MEGA: FINE: FU-24X Approx. 4 g FU-66TZ Approx. 10 g FU-66Z Approx. 10 g 0.59" 15 Parallel M4 2 m 6.56' Free-cut (ø2.2 ø0.09 x 2) 0.62" 15.8 -40 to +50˚C -40 to +122˚F Reflective R25 R0.98" 1 m 3.28' cut not allowed. 0.67" 17 -40 to +50˚C -40 to +122˚F Hex-shaped FU-67TZ R2 R0.08" ToughFlex M6 FU-66 Approx. 10 g 710 210 27.95" 8.27" Approx. 32 g FU-67TG Approx. 32 g M6 Coaxial 1 m 3.28' cut not allowed. -40 to +50˚C 0.89" 22.5 -40 to +122˚F R10 R0.39" Stainless Steel 270 170 110 32 10.63" 6.69" 4.33" 1.26" MEGA: 900 35.43" FINE: 210 8.27" ULTRA: SUPER: TURBO: HSP: 740 490 320 110 29.13" 19.29" 12.60" 4.33" MEGA: 1200 FINE: 300 47.24" 11.81" ULTRA: SUPER: TURBO: HSP: 900 590 430 140 35.43" 23.23" 16.93" 5.51" MEGA: 900 35.43" FINE: 210 8.27" ULTRA: SUPER: TURBO: HSP: 740 490 320 110 29.13" 19.29" 12.60" 4.33" 15.75" 2.76" Lens attachment: P.18 M6 2 m 6.56' Free-cut (ø2.2 ø0.09 x 2) 0.63" 16 -40 to +50˚C -40 to +122˚F ULTRA: SUPER: TURBO: HSP: MEGA: 400 FINE: 70 R0.5 R0.02" ToughFlex M6 2 m 6.56' Free-cut (ø2.2 ø0.09 x 2) 0.67" 17 -40 to +50˚C -40 to +122˚F M6 M6 2 m 6.56' Free-cut (ø2.2 ø0.09 x 2) 0.63" 16 -40 to +50˚C -40 to +122˚F R2 R0.08" ToughFlex Threaded FU-67V Approx. 25 g FU-61Z Approx. 22 g FU-67 M6 Parallel FU-35TG Approx. 32 g 1 m 3.28' cut not allowed. -40 to +50˚C 0.67" 17 -40 to +122˚F R10 R0.39" Stainless Steel Approx. 21 g FU-67G Approx. 29 g M6 2 m 6.56' Free-cut (ø2.2 ø0.09 x 2) 0.67"17 -40 to +70˚C -40 to +158˚F MEGA: 1300 51.18" FINE: 380 14.96" ULTRA: 1000 SUPER: 820 TURBO: 500 HSP: 160 39.37" 32.28" 19.69" 6.30" MEGA: 1100 43.31" FINE: 300 11.81" ULTRA: SUPER: TURBO: HSP: 860 570 410 140 33.86" 22.44" 16.14" 5.51" MEGA: FINE: ULTRA: SUPER: TURBO: HSP: 630 410 270 130 24.8" 16.14" 10.63" 5.12" M6 2 m 6.56' Free-cut (ø2.2 ø0.09 x 2) 0.67"17 -40 to +70˚C -40 to +158˚F R25 R0.98" M6 Coaxial 2 m 6.56' Free-cut (ø2.2 ø0.09 x 2) 0.67"17 -40 to +70˚C -40 to +158˚F M6 720 28.35" 160 6.30" FU-61 Approx. 21 g FU-6F Approx. 21 g FU-25 Approx. 18 g *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 15 Small size is suitable for installation in locations where space is limited. Installed by drilling a hole and using a set screw. C y linde r Thrubeam/reflective types Type Detecting method Size (mm inch) Fiber unit length (Diameter) Ambient temperature Appearance (mm inch) 50 cm 1.64' cut not allowed. -40 to +50˚C ø0.04" ø1 -40 to +122˚F ø1.0 ø0.04" ø1.5 ø0.06" 6 0.24" 1 m 3.28' Free-cut (ø1.0 ø0.04) ø0.06" ø1.5 -40 to +70˚C -40 to +158˚F 10 0.39" Optical axis diameter (mm inch) (Standard target to be detected) Detecting distance (mm inch)*1 Minimum bend radius (mm inch) MEGA FINE Other power modes R10 R0.39" MEGA: FINE: 380 85 14.96" 3.35" ULTRA: SUPER: TURBO: HSP: 270 180 120 40 10.63" 7.09" 4.72" 1.57" ø0.265 ø0.01" R4 R0.16" High-flex MEGA: FINE: 1200 230 47.24" 9.06" ULTRA: SUPER: TURBO: HSP: 810 590 410 130 31.89" 23.23" 16.14" 5.12" ø0.7 ø0.03" 50 cm 1.64' cut not allowed. -40 to +70˚C ø0.10" ø2.5 -40 to +158˚F ø2.5 ø0.10" 50 cm 1.64' cut not allowed. ø0.10" ø2.5 -40 to +70˚C -40 to +158˚F ø0.01" ø0.3 R10 R0.39" MEGA: FINE: 45 13 1.77" 0.51" ULTRA: SUPER: TURBO: HSP: 32 23 18 − 1.26" 0.91" 0.71" − ø0.125 ø005" FU-56 ø3 ø0.12" MEGA: FINE: 3600 880 171.73" 34.65" ULTRA: SUPER: TURBO: HSP: 3000 1800 1300 430 R25 R0.98" MEGA: FINE: 3600 1100 171.73" 43.30" ULTRA: SUPER: TURBO: HSP: 3200 125.98" 2200 86.61" 1500 59.06" 540 21.26" R4 R0.16" High-flex MEGA: FINE: 150 32 5.91" 1.26" ULTRA: SUPER: TURBO: HSP: 100 80 54 22 3.94" 3.15" 2.13" 0.87" 1 m 3.28' cut not allowed 0.59" -40 to +70˚C -40 to +158˚F 0.12" 15 3 ø1.5 ø0.5 ø0.06" ø0.02" Do not bend sleeve R10 R0.39" MEGA: FINE: 27 4.8 1.06" 0.19" ULTRA: SUPER: TURBO: HSP: 18 13 10 2.4 0.71" 0.51" 0.39" 0.09" 50 cm 1.64' cut not allowed 0.55" -40 to +70˚C 0.24" 14 -40 to +158˚F 6 ø2.5 ø1.77 ø0.10" ø0.07" Do not bend sleeve R25 R0.98" MEGA: FINE: 72 23 2.83" 0.91" ULTRA: SUPER: TURBO: HSP: 59 45 32 12 2.32" 1.77" 1.26" 0.47" R2 R0.08" ToughFlex MEGA: FINE: 770 190 30.32" 7.48" ULTRA: SUPER: TURBO: HSP: 560 380 260 80 22.05" 14.96" 10.24" 3.15" 860 570 410 140 33.86" 22.44" 16.14" 5.51" 2 m 6.56' Free-cut (ø2.2 ø0.09) -40 to +70˚C -40 to +158˚F ø0.12" ø3 15 0.59" 1 m 3.28' cut not allowed -40 to +70˚C 0.59" -40 to +158˚F 15 ø1.5 ø0.06" ø1.5 ø0.06" ø2.5 ø0.10" Approx. 3 g R2 R0.08" ToughFlex 14 0.55" 2 m 6.56' Free-cut (ø1.3 ø0.05 x 2) FU-4FZ: -40 to +50°C -40 to +122˚F FU-4F: -40 to +70˚C -40 to +158˚F 0.67" 17 Reflective ø3 ø0.12" R25 R0.98" MEGA: FINE: 1100 300 43.30" 11.81" ULTRA: SUPER: TURBO: HSP: R4 R0.16" High-flex MEGA: FINE: 290 63 11.42" 2.48" ULTRA: SUPER: TURBO: HSP: 200 130 80 32 7.87" 5.12" 3.15" 1.26" R25 R0.98" MEGA: FINE: 830 180 32.68" 7.09" ULTRA: SUPER: TURBO: HSP: 680 470 320 130 26.77" 18.50" 12.60" 5.12" R4 R0.16" MEGA: FINE: 68 18 2.68" 0.71" ULTRA: SUPER: TURBO: HSP: 54 40 27 8 2.13" 1.57" 1.06" 0.32" ø3 ø0.12" 50 cm 1.64' cut not allowed -40 to +70˚C 0.67" -40 to +158˚F 17 ø3 ø0.12" 50 cm 1.64' cut not allowed 0.59" -40 to +70˚C -40 to +158˚F 0.20" 15 5 ø3 ø0.82 ø0.12" ø0.03" Do not bend sleeve *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. 16 118.11" 70.87" 51.18" 16.93" ø1.13 ø0.04" ø1 ø0.04" FU-5FZ Approx. 19 g FU-5F Approx. 19 g FU-49X Approx. 3 g FU-46 Approx. 2 g FU-22X Approx. 4 g FU-4FZ Approx. 8 g − ø3 ø0.12" 2 m 6.56' Free-cut (ø1.0 ø0.04 x 2) -40 to +70˚C 0.59" -40 to +158˚F 15 FU-59 Approx. 3 g Approx. 3 g 10 0.39" 5 0.20" Do not bend sleeve 2 m 6.56' Free-cut (ø2.2 ø0.09) ø0.12" ø3 -40 to +50˚C -40 to +122˚F FU-58 Approx. 8 g FU-55 10 0.39" Thrubeam Model Weight FU-4F Approx. 8 g FU-48 Approx. 7 g FU-23X Approx. 4 g FU-45X Approx. 4 g Fibre Unit FU Series Sle eve Eliminate problems caused by limited mounting space. Thrubeam/reflective types Type Detecting method Beam emitting direction Sideview Fiber unit length (Diameter) Ambient temperature Appearance (mm inch) 1 m 3.28' Free-cut (ø1.3 ø0.05") -40 to +70˚C ø0.10" ø2.5 -40 to +158˚F ø0.82 ø0.03" 15 15 0.59" 0.59" Do not bend sleeve 2 m 6.56' Free-cut 0.59" (ø2.2 ø0.09") 15 -40 to +70˚C -40 to +158˚F ø3 ø0.12" 2.56" 65 R25 R0.98" ø1.2 ø0.05" R0.98" Min. bend radius of sleeve: R25 M4 2 m 6.56' Free-cut ø0.07" (ø2.2 ø0.09") ø1.65 -40 to +70˚C 15 0.59" -40 to +158˚F 2.64" 67 Min. bend radius of sleeve: R10 R0.39" 1 m 3.28' Free-cut ø0.03" M3 (ø1.0 ø0.04") ø0.82 -40 to +70˚C 15 -40 to +158˚F 15 0.59" 0.59" Thrubeam Top view Optical axis diameter (mm inch) (Standard target to be detected) Detecting distance (mm inch)*1 Minimum bend radius (mm inch) MEGA FINE Other power modes MEGA: FINE: 520 100 20.47" 3.94" ULTRA: SUPER: TURBO: HSP: 380 230 160 55 14.96" 9.06" 6.30" 2.17" MEGA: FINE: 1600 330 62.99" 12.99" ULTRA: 1100 SUPER: 660 TURBO: 470 HSP: 140 43.31" 25.98" 18.50" 5.51" ø0.6 ø0.02" Model Weight FU-32 Approx. 5 g FU-34 Approx. 17 g ø1 ø0.04" ULTRA: 3200 125.98" SUPER: 2200 86.61" TURBO: 1500 59.06" HSP: 540 21.26" FU-73 MEGA: FINE: 3600 1100 141.73" 43.31" MEGA: FINE: 690 170 27.17" 6.69" ULTRA: SUPER: TURBO: HSP: 500 340 240 72 19.69" 13.39" 9.45" 2.83" ø0.5 ø0.02" MEGA: FINE: 370 85 14.57" 3.35" ULTRA: SUPER: TURBO: HSP: 260 180 120 40 10.24" 7.09" 4.72" 1.57" ø0.265 ø0.01" MEGA: FINE: 45 13 1.77" 0.51" ULTRA: SUPER: TURBO: HSP: 32 23 18 − 1.26" 0.91" 0.71" − ø0.125 ø0.004" R10 R0.39" MEGA: FINE: 180 32 7.09" 1.26" ULTRA: SUPER: TURBO: HSP: 130 81 50 18 5.12" 3.19" 1.97" 0.71" R25 R0.98" MEGA: FINE: 320 45 12.60" 1.77" ULTRA: SUPER: TURBO: HSP: 250 140 90 32 9.84" 5.51" 3.54" 1.26" R4 R0.16" MEGA: FINE: 68 18 2.68" 0.71" ULTRA: SUPER: TURBO: HSP: 54 40 27 8 2.13" 1.57" 1.06" 0.32" R2 R0.08" ToughFlex MEGA: FINE: 290 54 11.42" 2.13" ULTRA: SUPER: TURBO: HSP: 190 120 80 23 7.48" 4.72" 3.15" 0.91" 12.99" 2.83" ULTRA: SUPER: TURBO: HSP: 230 150 100 36 9.06" 5.91" 3.94" 1.42" Approx. 24 g FU-75F Approx. 10 g Do not bend sleeve 1 m 3.28' Free- Free-cut ø3 (ø1.0 ø0.04") ø0.02" -40 to +70˚C ø0.4 -40 to +158˚F 1.77" 45 15 0.59" R10 R0.39" Min. bend radius of sleeve: R10 R0.39" 50 cm 1.64' cut not allowed ø0.10" ø2.5 -40 to +70˚C ø0.01" -40 to +158˚F ø0.3 10 0.39" 5 0.20" FU-76F Approx. 10 g FU-56 Approx. 3 g Do not bend sleeve Side 2 m 6.56' Free-cut ø0.11" (ø1.0 ø0.04" x 2) ø2.8 -40 to +70˚C ø0.08" -40 to +158˚F ø2 15 0.59" 15 0.59" Do not bend sleeve ø0.19" 1 m 3.28' Free-cut ø4.8 (ø2.2 ø0.09" x 2) -40 to +70˚C ø0.08" 15 -40 to +158˚F ø2.1 0.59" Min. bend 65 radius of 2.56" sleeve: R25 R0.98" 50 cm 1.64' cut not allowed -40 to +70˚C M3 -40 to +158˚F ø0.03" ø0.82 15 0.59" 15 0.59" Do not bend sleeve 2 m 6.56' Free-cut M4 (ø1.3 ø0.05" x 2) ø0.08" -40 to +50˚C 15 ø2 -40 to +122˚F 0.59" 67 2.64" Min. bend radius of sleeve: R10 R0.39" 2 m 6.56' Free-cut (ø1.3 ø0.05" x 2) ø0.07" -40 to +70˚C ø1.65 -40 to +158˚F Top FU-33 Approx. 10 g FU-65X Approx. 5 g FU-63Z Approx. 10 g M4 15 0.59" 67 2.64" Min. bend radius of sleeve: R10 R0.39" Reflective FU-31 Approx. 5 g 2 m 6.56' Free-cut (ø1.3 ø0.05 x 2) ø0.07" -40 to +70˚C ø1.65 -40 to +158˚F FU-63 Approx. 10 g R25 R0.98" 15 0.59" 5 0.20" 330 72 − FU-63T 15 0.59" 67 2.64" Min. bend radius of sleeve: R10 R0.39" 50 cm 1.64' cut not allowed ø0.12" -40 to +70˚C ø3 -40 to +158˚F ø0.03" ø0.82 MEGA: FINE: Approx. 10 g R4 R0.16" MEGA: FINE: 68 18 2.68" 0.71" ULTRA: SUPER: TURBO: HSP: 54 40 27 8 2.13" 1.57" 1.06" 0.32" R25 R0.98" MEGA: FINE: 330 72 12.99" 2.83" ULTRA: SUPER: TURBO: HSP: 230 150 100 36 9.06" 5.91" 3.94" 1.42" R10 R0.39" MEGA: FINE: 27 4.8 1.06" 0.19" ULTRA: SUPER: TURBO: HSP: 18 13 10 2.4 0.71" 0.51" 0.39" 0.09" R25 R0.98" MEGA: FINE: 72 23 2.83" 0.91" ULTRA: SUPER: TURBO: HSP: 59 45 32 12 2.32" 1.77" 1.26" 0.47" FU-45X Approx. 4 g Do not bend sleeve 2 m 6.56' Free-cut (ø1.3 ø0.05" x 2) ø0.07" -40 to +70˚C ø1.65 -40 to +158˚F ø4 15 0.59" 22 0.87" FU-43 Approx. 8 g Do not bend sleeve 1 m 3.28' cut not allowed -40 to +70˚C ø0.06" -40 to +158˚F ø0.02" ø1.5 ø0.5 15 0.59" 3 0.12" Coaxial, narrow beam 10° Do not bend sleeve 50 cm 1.64' cut not allowed ø0.10" -40 to +70˚C -40 to +158˚F ø0.07" ø2.5 ø1.77 14 0.55" 6 0.24" FU-46 Approx. 2 g FU-22X Approx. 4 g Do not bend sleeve *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 17 Ideal for detecting small objects. Select the sensor according to the size of the object. Small Spot Ref le cti ve Parallel Beam Spot Lens + Fiber Unit Type Beam spot diameter (mm inch) Lens Detecting distance (mm inch)*1 Fiber units Appearance (mm inch) Weight Model Minimum bend radius (mm inch) Appearance R2 R0.08" ToughFlex Parallel beam Approx. ø4 ø0.16" (within the detecting distance of 0 to 20 mm 0" to 0.79") FU-35FZ MEGA: 45 1.77" FINE: 36 FU-35FG 1.42" R10 R0.39" Stainless Steel ø0.17" Tip: ø4.3 MEGA FINE Model R25 R0.98" MEGA: 65 2.56" F-3HA FU-35FA FINE: 54 2.13" 9.5 0.37" R2 R0.08" ToughFlex Approx. 2 g FU-35TZ MEGA: 40 1.57" FINE: 27 FU-35TG 1.06" R10 R0.39" Stainless Steel F-3HA Other power modes ULTRA: SUPER: TURBO: HSP: 45 45 40 27 1.77" 1.77" 1.57" 1.06" ULTRA: SUPER: TURBO: HSP: 65 65 60 45 2.56" 2.56" 2.36" 1.77" ULTRA: SUPER: TURBO: HSP: 40 40 32 23 1.57" 1.57" 1.26" 0.91" *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. Small Beam Spot Lens + Fiber Unit Type Lens Beam spot diameter (mm inch) Focal distance (mm inch) Fiber units Appearance (mm inch) Weight Model Minimum bend radius (mm inch) Approx. ø0.1 ø0.004" R10 R0.39" Approx. ø0.2 ø0.008" R25 R0.98" ø0.17" Tip: ø4.3 7±2 0.28"±0.08" F-2HA 15.6 0.61" Approx. ø0.4 ø0.02" F-2HA Appearance FU-24X FU-21X R2 R0.08" ToughFlex FU-35FZ R10 R0.39" Stainless Steel FU-35FG R25 R0.98" FU-35FA Approx. 1 g Small spot Approx. ø0.5 ø0.02" ø0.29" Tip: ø7.4 15±2 0.59"±0.08" F-4HA 27 1.06" Approx. 2 g R2 R0.08" ToughFlex FU-35TZ R10 R0.39" Stainless Steel FU-35TG R2 R0.08" ToughFlex FU-35FZ R10 R0.39" Stainless Steel FU-35FG R2 R0.08" ToughFlex FU-35TZ R10 R0.39" Stainless Steel FU-35TG R25 R0.98" ø0.42" Tip: ø10.6 35±3 1.38"±0.12" Approx. ø2.0 ø0.08" F-6HA 26 1.02" Approx. 5 g F-4HA FU-35FA R25 R0.98" Approx. ø1.0 ø0.04" Model FU-21X R2 R0.08" ToughFlex FU-35FZ R10 R0.39" Stainless Steel FU-35FG R2 R0.08" ToughFlex FU-35TZ R25 R0.98" F-6HA FU-35FA Built-in Lens Fiber Unit Type Small spot Beam spot diameter Focal distance (mm inch) (mm inch) Approx. ø0.1 ø0.004" Fiber unit length (Diameter) Ambient temperature 50 cm 1.64' cut not allowed -40 to +70˚C -40 to +158˚F 5 0.20" Appearance (mm inch) Tip: ø3 ø0.12" 18 0.71" Model Weight Minimum bend radius (mm inch) FU-20 R25 R0.98" Approx. 2 g Adjustable Beam Spot Built-in Lens Fiber Unit Type Adjustable beam spot Beam spot diameter Focal distance (mm inch) (mm inch) ø0.9 to 3.5 ø0.04" to 0.14" 10 to 30 0.39" to 1.18" Fiber unit length (Diameter) Ambient temperature 2 m 6.56' Free-cut (ø1.3 ø0.05 x 2) -40 to +70˚C -40 to +158˚F Appearance (mm inch) M6 26.4 1.04" to 31.5 1.24" Model Weight Minimum bend radius (mm inch) FU-10 R25 R0.98" Approx. 5 g Lens + Fiber Unit Type Beam spot diameter (mm inch) Lens Focal distance (mm inch) Appearance (mm inch) Weight Fiber units Model 8.7 0.34" Side-view adjustable spot 18 ø0.5 to 3 ø0.02" to 0.12" 8 to 30 0.32" to 1.18" 5.6 0.22" Approx. 2g 15 0.59" F-5HA Minimum bend radius (mm inch) Appearance F-5HA Model R2 R0.08" ToughFlex FU-35FZ R10 R0.39" Stainless Steel FU-35FG R25 R0.98" FU-35FA Fibre Unit FU Series Great for applications where target position varies or for detecting targets with complicated shapes or rough surface fi nish. A re a Thrubeam/reflective types Type Detecting method Fiber unit length (Diameter) Optical axis Ambient width (mm inch) temperature Type Detecting distance (mm inch)*1 Minimum bend radius (mm inch) Appearance (mm inch) MEGA FINE 0.79" 20 2 m 6.56' Free-cut 20 (ø2.2 ø0.09") 0.79" -40 to +50˚C -40 to +122˚F 1.17" 29.8 0.41"10.5 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to +50˚C -40 to +122˚F Thickness: 4.0 0.16" 2.72" 69 0.77" 19.5 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to +50˚C -40 to +122˚F Thickness: 5.1 0.20" 0.59" 15 Thickness: 2 m 6.56' Free-cut 4.0 0.16" (ø2.2 ø0.09") 0.59" 15 -40 to +70˚C -40 to +158˚F 0.79" 20 Thickness: 4.0 2 m 6.56' Free-cut 0.16" 20 (ø2.2 ø0.09") 0.79" -40 to +70˚C -40 to +158˚F 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +70˚C -40 to +158˚F 15 0.59" 7 0.28" 28 1.10" 0.79" 20 20 0.79" 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +70˚C -40 to +158˚F Thickness: 4.0 0.16" 0.79" 20 20 0.79" 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +70˚C -40 to +158˚F Thickness: 4.0 0.16" 10 0.39" 11 0.43" Area 40 1.57" Thrubeam 5 0.20" Array 10 0.39" 15 0.59" (at distance 15 0.59") Area 10 0.39" (at distance 4 0.16") Refl ective Array 15 0.59" (at distance 4 0.16") R2 R0.08" ToughFlex R4 R0.16" R25 R0.98" Optical axis diameter (mm inch) Other power modes MEGA: 3400 133.86" FINE: 1400 55.12" ULTRA: 2800 SUPER: 2400 TURBO: 1700 HSP: 640 110.24" 94.49" 66.93" 25.20" 10×3 0.39"×0.12" Approx. 23 g MEGA: 3600 141.73" FINE: 2700 106.30" ULTRA: SUPER: TURBO: HSP: 3600 3600 3600 1300 141.73" 141.73" 141.73" 51.18" 11×2 0.43"×0.08" Approx. 20 g MEGA: 3600 141.73" FINE: 3600 141.73" ULTRA: SUPER: TURBO: HSP: 3600 3600 3600 2500 141.73" 141.73" 141.73" 98.43" 40×3 1.57"×0.12" Approx. 30 g MEGA: 2200 FINE: 440 ULTRA: 1400 840 SUPER: TURBO: 540 HSP: 200 55.12" 33.07" 21.25" 7.87" 86.61" 17.32" MEGA: 5 to 200 0.20" to 7.87" FINE: 5 to 140 0.20" to 5.51" ULTRA: SUPER: TURBO: HSP: MEGA: FINE: ULTRA: SUPER: TURBO: HSP: 5 to 200 5 to 200 5 to 160 5 to 110 Approx. 6 x 0.3 0.24"×0.01" Approx. 11 x 0.3 0.43"×0.01" 0.20" to 7.87" 0.20" to 7.87" 0.20" to 6.30" 0.20" to 4.33" 740 140 29.13" 5.51" 460 260 180 60 FU-12 FU-E11 FU-E40 FU-A05 Approx. 20 g FU-A10 Approx. 20 g FU-11 − Approx. 19 g FU-A05D − R4 R0.16" Model Weight Approx. 20 g 18.11" 10.24" 7.09" 2.36" FU-A10D − Approx. 20 g *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. Retro-ref le cti ve Useful for detecting transparent objects. Retro-reflective type Type Detecting method Fiber unit length Appearance Beam emitting (Diameter) Ambient temperature (mm inch) direction 2 m 6.56' Free-cut (ø1.0 ø0.04" x 2) -40 to +50˚C -40 to +122˚F M6 0.67" 17 Square type 2 m 6.56' Free-cut (ø1.0 ø0.04" x 2) -40 to +50˚C -40 to +122˚F 26.9 1.06" 0.79" 20.8 Thickness: 12.6 0.50" MEGA FINE Other power modes R2 R0.08" ToughFlex MEGA: 10 to 960 0.39" to 37.80" FINE: 10 to 120 0.39" to 4.72" ULTRA: SUPER: TURBO: HSP: R10 R0.39" MEGA: 100 to 6400 4.72" to 251.97" FINE: 100 to 1260 4.72" to 49.61" ULTRA: SUPER: TURBO: HSP: Reflective tape (accessory) M6 RetroReflective Detecting distance (mm inch)*1 Minimum bend radius (mm inch) Reflector R-2 (accessory) 10 to 760 0.39" to 29.92" 10 to 380 0.39" to 14.96" 10 to 230 0.39" to 9.06" − − 100 to 5000 100 to 2500 100 to 1690 100 to 1000 4.72" to 196.85" 4.72" to 98.43" 4.72" to 66.54" 4.72" to 39.37" Model Weight FU-13 Approx. 8 g FU-15 Approx. 12 g *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. Reflector/Reflective Tape Specifications (Optional Parts) Detecting distance (mm inch)*1 R-2 (OP-95388) Model FU-13 Power modes 51.2 x 61 (2.02" x 2.40") R-5 35 x 42 (1.38" x 1.65") Reflective tape (OP-96629) 14 x 36 (0.55" x 1.42") 40 x 30 (1.57" x 1.18") MEGA 10 to 1880 0.39" to 74.02" 10 to 1540 0.39" to 60.63" 10 to 1060 0.39" to 41.73" 10 to 960 0.39" to 37.80" ULTRA 10 to 1500 0.39" to 59.06" 10 to 1240 0.39" to 48.82" 10 to 860 0.39" to 33.86" 10 to 760 0.39" to 29.92" SUPER 10 to 760 0.39" to 29.92" 10 to 640 0.39" to 25.20" 10 to 440 0.39" to 17.32" 10 to 380 0.39" to 14.96" TURBO 10 to 450 0.39" to 17.72" 10 to 360 0.39" to 14.17" 10 to 230 0.39" to 9.06" 10 to 230 0.39" to 9.06" FINE 10 to 250 0.39" to 9.84" 10 to 200 0.39" to 7.87" 10 to 130 0.39" to 5.12" 10 to 120 HSP FU-15* 2 R-3 (OP-96436) − − − 0.39" to 4.72" − MEGA 100 to 6400 3.94" to 251.97" 100 to 4400 3.94" to 173.23" 100 to 2600 ULTRA 100 to 5000 3.94" to 196.85" 100 to 3600 3.94" to 141.73" 100 to 2200 3.94" to 102.36" 3.94" to 86.61" SUPER 100 to 2500 3.94" to 98.43" 100 to 2000 3.94" to 78.74" 100 to 1500 3.94" to 59.06" TURBO 100 to 1690 3.94" to 66.54" 100 to 1350 3.94" to 53.15" 100 to 1200 3.94" to 47.24" FINE 100 to 1260 3.94" to 47.61" 100 to 1000 3.94" to 39.37" 100 to 1000 3.94" to 39.37" HSP 100 to 1000 3.94" to 39.37" 100 to 860 3.94" to 33.86" 100 to 860 3.94" to 33.86" − *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. *2 Reflective tape cannot be used. Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 19 Built-in lens reduces beam width and helps reduce stray light. Narrow Beam/High-power Thrubeam/reflective types Detecting method Fiber unit length Type (Diameter) Beam emitting Aperture angle Ambient direction temperature Appearance (mm inch) 2 m 6.56' Free-cut (ø1.0 ø0.04") FU-16Z: -40 to +50˚C -40 to +122˚F FU-16/18: -40 to +70˚C -40 to +158˚F Approx. 6° 17 0.67" Approx. 2° Thrubeam Approx. 3° Top Reflective Top Approx. 6° Approx. 8° MEGA FINE Other power modes R2 R0.08" ToughFlex MEGA: 3600 141.73" FINE: 1260 49.61" ULTRA: 3600 141.73" SUPER: 2600 102.36" TURBO: 1800 70.87" HSP: 760 29.92" MEGA: 3600 141.73" FINE: 1900 74.80" ULTRA: SUPER: TURBO: HSP: MEGA: 3600 141.73" FINE: 1600 62.99" ULTRA: 3600 141.73" SUPER: 3000 118.11" TURBO: 2100 92.68" HSP: 960 37.80" MEGA: 1300 FINE: 330 51.18" 12.99" ULTRA: SUPER: TURBO: HSP: MEGA: 3600 141.73" FINE: 3600 141.73" ULTRA: SUPER: TURBO: HSP: MEGA: 30 to 2300 1.18" to 90.55" FINE: 30 to 290 1.18" to 11.42" ULTRA: 30 to 1600 1.18" to 62.99" SUPER: 30 to 760 1.18" to 29.92" TURBO: 30 to 410 1.18" to 16.14" HSP: 30 to 160 1.18" to 6.30" ø0.16" ø4 Side 13 0.51" R10 R0.39" 2 m 6.56' Free-cut (ø1.0 ø0.04") -40 to +70˚C -40 to +158˚F 1.5 0.06" 2 20 0.79" 0.08" 2 m 6.56' Free-cut (ø1.0 ø0.04") -40 to +50˚C 0.16" -40 to +122˚F 4 12 0.47" 3.6 0.14" 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +50˚C -40 to +122˚F Thickness: 5.2 0.20" 21 0.83" 1 m 3.28' cut not allowed -40 to +50˚C -40 to +122˚F Thickness: 5.2 0.20" Detecting distance (mm inch)*1 Minimum bend radius (mm inch) 21 0.83" R2 R0.08" ToughFlex R2 R0.08" ToughFlex R10 R0.39" Stainless Steel Optical axis diameter (mm inch) (Standard target to be detected) 3600 141.73" 3600 141.73" 2700 106.30" 1000 39.37" 900 680 530 210 FU-16Z Approx. 8 g ø2.5 ø0.10" FU-16 Approx. 8 g FU-18 Approx. 8 g 35.43" 26.77" 20.87" 8.27" 3600 141.73" 3600 141.73" 3600 141.73" 2400 94.49" Model Weight ø1 ø0.04" ø2.8 ø0.11" FU-18M Approx. 6 g FU-50 Approx. 8 g FU-40 Approx. 23 g − FU-40G Approx. 50 g *1 3600 mm 141.73" is assumed as maximum because the fiber cable has a length of 2 m 6.56'. Detecting distance for reflective fibers is based on a standard target: White matte paper. Helps reduce the effect of target background. The thin, small design requires less space. D ef in i te -ref l e c ti ve Definite-reflective types Fiber unit length (Diameter) Beam emitting Ambient direction temperature Type Detecting method Side 2 m 6.56' Free-cut (ø1.0 ø0.04" x 2) -40 to +70˚C -40 to +158˚F Appearance (mm inch) 14.4 0.57" Thickness: 19 0.75" 5 0.20" 2 m 6.56' Free-cut (ø1.0 ø0.04" x 2) -40 to +70˚C -40 to +158˚F Definitereflective Top 12 0.47" R10 R0.39" 19 Thickness: 0.75" 4 0.16" 2 m 6.56' Free-cut (ø1.0 ø0.04" x 2) -40 to +70˚C -40 to +158˚F Detecting distance (mm inch)*1 Minimum bend radius (mm inch) MEGA FINE Other power modes MEGA: 3 (0.12") center of detecting distance FINE: 3 (0.12") center of detecting distance ULTRA: 3 (0.12") center of detecting distance SUPER: 3 (0.12") center of detecting distance TURBO: 3 (0.12") center of detecting distance HSP: 3 (0.12") center of detecting distance MEGA: 6 (0.24") center of detecting distance FINE: 6 (0.24") center of detecting distance ULTRA: 6 (0.24") center of detecting distance SUPER: 6 (0.24") center of detecting distance TURBO: 6 (0.24") center of detecting distance HSP: 6 (0.24") center of detecting distance MEGA: 0 to 4 0" to 0.16" FINE: 0 to 4 0" to 0.16" ULTRA: SUPER: TURBO: HSP: 12 0.47" Thickness: 19 4.3 0.17" 0.75" *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. 20 0 to 4 0 to 4 0 to 4 2±1.4 0" to 0.16" 0" to 0.16" 0" to 0.16" 0.08"±0.06" Beam spot diameter (mm inch) Approx. ø4.5 ø0.18 Approx. ø3.5 ø0.14 (at distance of 3 0.12") Approx. ø1.5 ø0.06" (at distance of 6 0.24") − Model Weight FU-37 Approx. 6 g FU-38 Approx. 5 g FU-38V Approx. 5 g Fibre Unit FU Series Provides higher fl exibility than electric wire. R2 (R0.08") types are resistant to repeated bends up to 10 million bends. High-f lex Thrubeam/reflective types Type Detecting method Size (mm inch) ø1.5 ø0.06" M3 Fiber unit length (Diameter) Ambient temperature 1 m 3.28' Free-cut (ø1.0 ø0.04" ) -40 to +70˚C -40 to +158˚F MEGA FINE Other power modes FU-59 10 0.39" M3 MEGA: 1200 FINE: 230 47.24" 9.06" R4 R0.16" High-flex 10 0.39" 1 m 3.28' Free-cut Thrubeam MEGA: FINE: 0.24" 6 1 m 3.28' Free-cut (ø1.0 ø0.04" ) -40 to +50˚C -40 to +122˚F ø0.04" ø1 1 m 3.28' Free-cut (ø1.0 ø0.04" ) -40 to +50˚C -40 to +122˚F ø0.06" ø1.5 ø1.5 ø0.06" M3 1 m 3.28' Free-cut (ø1.0 ø0.04" ) -40 to +50˚C -40 to +122˚F M4 M4 Built-in lens ø1.5 ø0.06" 1 m 3.28' cut not allowed ø0.06" ø1.5 -40 to +70˚C -40 to +158˚F R2 R0.08" ToughFlex High-flex ø3 ø0.12" M3 2 m 6.56' Free-cut (ø1.0 ø0.04" x 2) ø0.12" ø3 -40 to +70˚C -40 to +158˚F 19.29" 11.42" 7.09" 2.56" FU-79 Approx. 6 g FU-57TE Approx. 5 g MEGA: FINE: 590 140 23.23" 5.51" ULTRA: SUPER: TURBO: HSP: 430 300 180 55 16.93" 11.81" 7.09" 2.17" ø0.5 ø0.02" FU-59U Approx. 4 g FU-79U MEGA: 1800 FINE: 850 70.87" 33.46" ULTRA: 1800 SUPER: 1800 TURBO: 1200 HSP: 370 70.87" 70.87" 47.24" 14.57" ø2.3 ø0.09" FU-70U Approx. 5 g FU-49X MEGA: FINE: 150 32 5.91" 1.26" ULTRA: SUPER: TURBO: HSP: 100 80 54 22 3.94" 3.15" 2.13" 0.87" Approx. 3 g FU-69X Approx. 3 g 0.39" R4 R0.16" High-flex FU-48 15 0.59" MEGA: FINE: M4 290 63 11.42" 2.48" ULTRA: SUPER: TURBO: HSP: 200 130 80 32 7.87" 5.12" 3.15" 1.26" Approx. 7 g FU-68 − Approx. 8 g 15 0.59" 1 m 3.28' Free-cut ø0.08" ø2 (ø1.0 ø0.04" x 2) -40 to +50˚C -40 to +122˚F 10 1 m 3.28' Free-cut ø0.12" ø3 (ø1.0 ø0.04" x 2) -40 to +50˚C -40 to +122˚F 10 1 m 3.28' Free-cut (ø1.0 ø0.04" x 2) -40 to +50˚C -40 to +122˚F ø0.7 ø0.03" Approx. 4 g 13 0.51" 10 ø2 ø0.08" Approx. 3 g 10 0.39" 1 m 3.28' cut not allowed M3 -40 to +70˚C -40 to +158˚F 2 m 6.56' Free-cut (ø1.0 ø0.04" x 2) -40 to +70˚C -40 to +158˚F 490 290 180 65 31.89" 23.23" 16.14" 5.12" FU-58U 15 0.59" M4 ULTRA: SUPER: TURBO: HSP: 810 590 410 130 Approx. 4 g 10 0.39" 1 m 3.28' Free-cut (ø1.0 ø0.04" ) -40 to +50˚C -40 to +122˚F Reflective 24.80" 4.33" ULTRA: SUPER: TURBO: HSP: 6 0.24" M3 ø3 ø0.12" 630 110 10.5 0.41" ø1.0 ø0.04" M3 Model Weight ø0.06" ø1.5 1 m 3.28' Free-cut (ø1.0 ø0.04" ) -40 to +70˚C -40 to +158˚F (ø1.0 ø0.04" ) 6×10.5×2.5 to +70˚C 0.24"×0.41"×0.10" -40 -40 to +158˚F Optical axis diameter (mm inch) (Standard target to be detected) Detecting distance (mm inch)*1 Minimum bend radius (mm inch) Appearance (mm inch) FU-49U Approx. 4 g 0.39" R2 R0.08" ToughFlex High-flex 0.39" MEGA: FINE: 140 40 5.51" 1.57" ULTRA: SUPER: TURBO: HSP: 110 80 60 13 4.33" 5.12" 2.36" 0.51" FU-48U Approx. 4 g M3 FU-69U Approx. 4 g 13 0.51" *1 Detecting distance for reflective fibers is based on a standard target: White matte paper. Oil/Chemical Resistant PTFE coating allows for use in almost any environment. Thrubeam/Reflective types Type Detecting Beam emitting method direction Top Size (mm inch) ø5 ø0.20" Fiber unit length (Diameter) Ambient temperature Appearance (mm inch) 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to +70˚C -40 to +158˚F 22 0.87" Detecting distance (mm inch)*1 Minimum bend radius (mm inch) MEGA FINE Other power modes R40 R1.57" MEGA: 3600 141.73" FINE: 2800 110.24" ULTRA: SUPER: TURBO: HSP: 3600 141.73" 3600 141.73" 3600 141.73" 1400 55.12" ø3.7 ø0.15" R40 R1.57" MEGA: 3600 141.73" FINE: 1100 43.31" ULTRA: 3600 141.73" SUPER: 3000 118.11" TURBO: 2200 86.61" HSP: 510 20.08" ø2.8 ø0.11" R40 R1.57" MEGA: FINE: ULTRA: SUPER: TURBO: HSP: ø5 ø0.87" Thrubeam Side Reflective Top ø5 ø0.20" ø4.5 ø0.18" 2 m 6.56' Free-cut (ø2.2 ø0.09") -40 to +70˚C -40 to +158˚F ø0.20" ø5 23 1.44" 2 m 6.56' Free-cut (ø1.3 ø0.05" x 2) -40 to +70˚C -40 to +158˚F ø0.18" ø4.5 22 0.87" Optical axis diameter (mm inch) (Standard target to be detected) 310 140 12.20" 5.51" 290 250 200 80 11.42" 9.84" 7.87" 3.15" − Model Weight FU-92 Approx. 71 g FU-96 Approx. 71 g FU-91 Approx. 32 g *1 3600 mm 141.73" is assumed as maximum because the fiber cable has a length of 2 m 6.56'. Detecting distance for reflective fibers is based on a standard target: White matte paper. Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 21 He at Re sista nt Resists temperatures up to 350°C (662°F). A wide variety of heat-resistant types are available, including the easy-to-install R5(R0.20") type and the high-temperature type, resistant to temperatures up to 350°C (662°F). Fibers used in sensors resistant to temperatures of 200°C (392°F) or more are made from multi-component glass. Thrubeam/reflective types Fiber unit length (Diameter) Heat resistant Ambient 2 temperatures* temperature Type Detecting method Appearance (mm inch) 2 m 6.56' Free-cut (ø2.2 ø0.09" ) -40 to +100˚C 100˚C 212˚F*3 -40 to +212˚F 15 0.59" M4 105˚C 221˚F* 3 R5 R0.20" ToughFlex MEGA FINE Other power modes MEGA: 3600 141.73" FINE: 680 26.77" Lens attachment: P14 15 0.59" M4 R25 R0.98" 17 0.67" MEGA: 3600 141.73" FINE: 1100 43.31" Lens attachment: P14 2 m 6.56' Free-cut (ø2.2 ø0.09" ) -40 to +150˚C 180˚C 356˚F* 5 2 m 6.56' Free-cut (ø2.2 ø0.09" ) -60 to +180˚C -76 to +356˚F 2 m 6.56' cut not allowed. -40 to +200˚C -40 to +392˚F M4 300˚C 572˚F 2 m 6.56' cut not allowed. -40 to +300˚C -40 to +572˚F M4 17 0.67" 10 0.39" 15 0.59" 10 0.39" 15 0.59" 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +100˚C M6 ULTRA: 1800 SUPER: 1100 TURBO: 720 HSP: 340 70.87" 43.31" 28.35" 13.39" R35 R1.38" MEGA: 2700 106.30" FINE: 570 22.44" ULTRA: 1900 SUPER: 1200 TURBO: 790 HSP: 380 74.80" 47.24" 31.10" 14.96" ULTRA: 1300 SUPER: 900 TURBO: 680 HSP: 250 51.18" 35.43" 26.77" 9.84" R8 R0.32" 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +105˚C M6 105˚C 221˚F*3 -40 to +221˚F R25 R0.98" 70.87" 15.35" M6 MEGA: FINE: 740 160 29.13" 6.30" ULTRA: SUPER: TURBO: HSP: 580 410 320 90 22.83" 16.14" 12.60" 3.54" R25 R0.98" MEGA: 1100 FINE: 230 43.31" 9.06" ULTRA: SUPER: TURBO: HSP: 860 590 410 140 33.86" 23.23" 16.14" 5.51" R20 R0.79" MEGA: FINE: 720 160 28.35" 6.30" ULTRA: SUPER: TURBO: HSP: 560 410 320 90 22.05" 16.14" 12.60" 3.54" R35 R1.38" MEGA: FINE: 860 200 33.86" 7.87" ULTRA: SUPER: TURBO: HSP: 710 470 350 100 27.95" 18.50" 13.78" 3.94" 17 0.67" 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -60 to +180˚C M6 17 0.67" Reflective 300˚C 572˚F 350˚C 662˚F FU-85Z Approx. 25 g FU-85A Approx. 21 g FU-85H Approx. 35 g FU-87 Approx. 33 g FU-87K 770 190 30.32" 7.48" ULTRA: SUPER: TURBO: HSP: 650 450 340 100 25.59" 17.72" 13.38" 3.94" − FU-82C Approx. 29 g FU-83C R25 R0.98" 1 m 3.28' cut not allowed. M4 -30 to +350˚C 40 1.57" -22 to +572˚F ø2.1 ø0.08" 90 Min. bend radius of 3.54" sleeve R10 R0.39" 2 m 6.56' cut not allowed. -40 to +250˚C Thickness: 5 0.67" -40 to +482˚F 0.20" 17.1 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) 0.75" -60 to +180˚C 19 -76 to +356˚F FU-84C Approx. 15 g MEGA: FINE: Approx. 23 g MEGA: FINE: 650 140 25.59" 5.51" ULTRA: SUPER: TURBO: HSP: 560 390 290 86 22.05" 15.35" 11.42" 3.39" MEGA: 8 to 37 0.32" to 1.46" FINE: 8 to 30 0.32" to 1.18" ULTRA: 8 to 34 0.32" to 1.34" SUPER: 8 to 32 0.32" to 1.26" TURBO: 8 to 30 0.32" to 1.18" HSP: 10 to 18 0.39" to 0.71" MEGA: 2.5 to 65 0.10" to 2.56" FINE: 2.5 to 16 0.10" to 0.63" ULTRA: 2.5 to 55 0.10" to 2.17" SUPER: 2.5 to 27 0.10" to 1.06" TURBO: 2.5 to 22 0.10" to 0.87" HSP: 2.5 to 10 0.10" to 0.39" FU-81C Approx. 24 g FU-38LK Approx. 70 g R25 R0.98" Thickness: 5 0.20" 27 1.06" 180˚C 356˚F ø1 ø0.04" R8 R0.32" 1 m 3.28' cut not allowed. M4 -40 to +300˚C 35 1.38" -40 to +572˚F ø0.08" ø2.1 90 Min. bend radius of 3.54" sleeve R10 R0.39" 1 m 3.28' cut not allowed. M4 -40 to +300˚C ø0.10" -40 to +572˚F ø2.6 10 0.39" 17 0.67" 1 m 3.28' cut not allowed. -40 to +250˚C 0.75" -40 to +482˚F 19 Approx. 30 g 10 0.39" 17 0.67" 29.7 1.17" 250˚C 482˚F FU-88 Approx. 36 g Approx. 66 g R5 R0.20" ToughFlex 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +150˚C 1 m 3.28' cut not allowed. -40 to +200˚C -40 to +392˚F M4 FU-86H Approx. 35 g Lens attachment: P14 17 0.67" 200˚C 392˚F FU-86A Approx. 22 g FU-88K MEGA: 1800 FINE: 390 17 0.67" 180˚C 356˚F*5 -76 to +356˚F FU-86Z ø1.5 ø0.06" 100˚C 212˚F*3 -40 to +212˚F 150˚C 302˚F*4 -40 to +302˚F Model Weight Approx. 25 g ULTRA: 3200 125.98" SUPER: 2200 86.61" TURBO: 1500 59.06" HSP: 540 21.26" MEGA: 2700 106.30" FINE: 520 20.47" M4 200˚C 392˚F 86.61" 62.99" 35.43" 15.35" R20 R0.79" M4 Thrubeam ULTRA: 2200 SUPER: 1600 TURBO: 900 HSP: 390 Optical axis diameter (mm inch) (Standard target to be detected) ø1 ø0.04" 2 m 6.56' Free-cut (ø2.2 ø0.09" ) -40 to +105˚C -40 to +221˚F 150˚C 302˚F*4 -40 to +302˚F Detecting distance (mm inch)*1 Minimum bend radius (mm inch) Thickness: 5 0.20" 27 1.06" R35 R1.38" FU-38K Approx. 45 g FU-38H Approx. 45 g *1 Detecting distance for reflective fibers is based on a standard target: White matte paper.(For the FU-38LK, the distances are based on a glass substrate (t = 0.7 mm 0.03") detected in the planar direction.) *2 Use the fiber sensor under dry conditions. Allow some margin for the temperature upper limit when selecting a heat-resistant fiber unit. *3 The recommended maximum ambient temperature during operation is 90°C 194°F when constantly using a fiber unit in a high-temperature environment. *4 The recommended maximum ambient temperature during operation is 130°C 266°F when constantly using a fiber unit in a high-temperature environment. *5 The recommended maximum ambient temperature during operation is 150°C 302°F when constantly using a fiber unit in a high-temperature environment. 22 Fibre Unit FU Series Liquid-level detection sensors. Available in tube-mountable and immersible types. L iquid-leve l Reflective Type Transparent tube diameter (mm inch) Detecting method Fiber unit length (Diameter) Ambient temperature Beam axis Appearance (mm inch) 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +70˚C -40 to +158˚F 16 2 m 6.56' Free-cut (ø1.0 ø0.04" x 2) FU-95Z: -40 to +50°C -40 to +122˚F FU-95HA: -40 to +105°C -40 to +221˚F FU-95: -40 to +70˚C -40 to +158˚F Minimum bend radius (mm inch) Accessory R5 R0.20" Binding band x 2 Nonslip rubber x 2 FU-95S Approx. 23 g FU-95Z R2 R0.08" ToughFlex Approx. 7 g ø4 to 26 ø0.16" to 1.02" Tube-mountable type Model Weight 1 Binding band x 2 Nonslip rubber x 2 Spacer x 2 Screw x 2 Nut x 2 R25 R0.98" FU-95HA Approx. 7 g FU-95 R10 R0.39" ø26 ø1.02" or more recommended Type Fiber unit length (Diameter) Ambient temperature Detecting method 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +70˚C -40 to +158˚F 16 Approx. 7 g Minimum bend radius (mm inch) Appearance (mm inch) Fiber Model Weight R0.5 R0.02" ToughFlex Approx. 78 g PFA-sheathed section 2 m 6.56' Free-cut (ø1.3 ø0.05" x 2) FU-93Z: -40 to +50°C -40 to +158˚F FU-93 : -40 to +70°C -40 to +158˚F FU-95W None (Optionally available) R5 R0.20" Approx. 20 g FU-93Z R40 R1.57" * Immersion FU-93 R25 R0.98" ø6 (PFA) ø0.24" Approx. 78 g * Not bendable up to 80 mm (3.15") from the tip. Perfect for detecting glass substrates. Lineup offers distance alignment, edge detection, and wafer mapping types. Liquid Crystal/Semiconductors Thrubeam Application Fiber unit length Type (Diameter) Beam emitting Aperture angle Ambient direction temperature Mapping Side Approx. 3° Minimum bend radius (mm) Appearance (mm inch) 2 m 6.56' Free-cut (ø1.0 ø0.04") -40 to +70˚C -40 to +158˚F 1.5 0.06" 0.08" 2 20 0.79" R10 R0.39" Detecting distance (mm inch)*1 MEGA FINE Other power modes MEGA: 1300 51.18" FINE: 330 12.99" ULTRA: SUPER: TURBO: HSP: 900 35.43" 680 26.77" 530 20.87" 210 8.27" Optical axis diameter (mm inch) (Standard target to be detected) ø1 ø0.04" Model Weight FU-18M Approx. 6 g Reflective Type Application Beam emitting direction Glass substrate mapping Top Heat resistant*2 temperatures Fiber unit length (Diameter) Ambient temperature Appearance (mm inch) 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +70˚C -40 to +158˚F 0.75" 19 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -10 to +60˚C 14 to +140˚F Glass substrate alignment − Flat 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +70˚C -40 to +158˚F 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +70˚C -40 to +158˚F 2 m 6.56' Free-cut (ø1.0 ø0.04" x 2) -40 to +70˚C -40 to +158˚F Seating check 2 m 6.56' cut not allowed. -40 to +250˚C -40 to +482˚F 0.67" 17.1 Heat-resistant glass substrate alignment 250˚C 482˚F Flat Heat-resistant seating, presence check 180˚C 356˚F*3 1 m 3.28' cut not allowed. -40 to +250˚C -40 to +482˚F 0.75" 19 2 m 6.56' Free-cut (ø2.2 ø0.09" x 2) -40 to +180˚C 0.75" 19 -40 to +356˚F Minimum bend radius (mm inch) ULTRA: 15 to 60 0.59" to 2.36" SUPER: 15 to 46 0.59" to 1.81" TURBO: 15 to 38 0.59" to 1.50" HSP: − − MEGA: 8 to 38 0.32" to 1.50" FINE: 8 to 32 0.32" to 1.26" ULTRA: 8 to 36 SUPER: 8 to 35 TURBO: 8 to 34 HSP: 10 to 26 R5 R0.20" MEGA: 0 to 25 0" to 0.98" FINE: 0 to 25 0" to 0.98" ULTRA: SUPER: TURBO: HSP: 0 to 25 0 to 25 0 to 25 − 0" to 0.98" 0" to 0.98" 0" to 0.98" − R25 R0.98" MEGA: 0 to 14 0" to 0.55" FINE: 0 to 14 0" to 0.55" ULTRA: SUPER: TURBO: HSP: 0 to 14 0 to 14 0 to 14 0 to 12 0" to 0.55" 0" to 0.55" 0" to 0.55" 0" to 0.47" R10 R0.39" MEGA: 0 to 4 0" to 0.16" FINE: 0 to 4 0" to 0.16" ULTRA: SUPER: TURBO: HSP: 0 to 4 0 to 4 0 to 4 2±1.4 0" to 0.16" 0" to 0.16" 0" to 0.16" 0.08"±0.06" MEGA: 8 to 37 0.32" to 1.46" FINE: 8 to 30 0.32" to 1.46" ULTRA: 8 to 34 0.32" to 1.34" SUPER: 8 to 32 0.32" to 1.26" TURBO: 8 to 30 0.32" to 1.18" HSP: 10 to 18 0.39" to 0.71" MEGA: 2.5 to 65 0.10" to 2.56" FINE: 2.5 to 16 0.10" to 0.63" ULTRA: SUPER: TURBO: HSP: 17 0.67" 20.5 0.81" 29 Thickness: 1.14" 3.6 0.14" 22 0.87" 29 Thickness: 1.14" 3.8 0.15" 12 0.47" 29.7 Thickness: 1.17" 5 0.20" Model Weight FU-40S Approx. 25 g R25 R0.98" 20 Thickness: 0.79" 5.2 0.20" 19 Thickness: 0.75" 4.3 0.17" Other power modes MEGA: 15 to 70 0.59" to 2.76" FINE: 15 to 30 0.59" to 1.18" 7.4 0.29" 14 0.55" Detecting distance (mm inch)*1 MEGA FINE 0.32" to 1.42" 0.32" to 1.38" 0.32" to 1.34" 0.39" to 1.02" FU-38L Approx. 20 g FU-38S Approx. 20 g FU-38R Approx. 20 g FU-38V Approx. 5 g FU-38LK Approx. 70 g R25 R0.98" FU-38K Thickness: 27 1.06" 5 0.20" R35 R1.38" 27 Thickness: 1.06" 5 0.20" 2.5 to 55 2.5 to 27 2.5 to 22 2.5 to 10 0.10" to 2.17" 0.10" to 1.06" 0.10" to 0.87" 0.10" to 0.39" Approx. 45 g FU-38H Approx. 45 g *1 Detecting distance for reflective fibers is based on a standard target: White matte paper.(For the FU-38LK, the distances are based on a glass substrate (t = 0.7 mm 0.03") detected in the planar direction.) *2 Use the fiber sensor under dry conditions. Allow some margin for the temperature upper limit when selecting a heat-resistant fiber unit. *3 The recommended maximum ambient temperature during operation is 150°C 302°F when constantly using a fiber unit in a high-temperature environment. Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 23 Spe cif ic ations Standard 1 output Monitor output High functionality 2 output Type M8 connector*1 Cable M8 connector*1 Cable Cable NPN FS-N11N FS-N12N FS-N11CN FS-N12CN FS-N13N FS-N14N – – FS-N11MN PNP FS-N11P FS-N12P FS-N11CP FS-N12CP FS-N13P FS-N14P FS-N13CP FS-N14CP – Main unit Expansion unit Main unit Expansion unit Main unit Expansion unit Main unit Expansion unit Main unit Control output 1 1 1 1 2 2 2 2 1 Monitor output (1-5 V) – – – – – – – – 1 External input – – 1 1 1 1 – – – Model Main unit/Expansion unit Response time 50 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) NPN output NPN open collector 30 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/ 20 mA or less (multiple connections); residual voltage 1 V or less PNP output PNP open collector 30 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/ 20 mA or less (multiple connections); residual voltage 1 V or less Control output Monitor output*2 1 to 5 V voltage output; load resistance 10 kΩ or more; repeat precision ±0.5% of F.S.; 1 ms response time (HIGH SPEED, FINE, TURBO)*3 External input input time 2 ms (ON)/20 ms (OFF) or more Multiple connections to Expansion units Up to 16 units can be connected total (two output type is treated as two units) Light source Red, 4-element LED APC ON/OFF switchable (Factory setting: OFF) Number of interference prevention units 0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA (When set to double, the number of interference-prevention units will be doubled.) Power voltage 12 - 24 V DC ±10% ripple (P-P) 10% or less NPN Amplifier Current Consumption Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*4 Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*4 Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V) Rating PNP Amplifier Current Consumption Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)*4 Normal: 1050 mW or less (42 mA max. at 24 V, 56 mA max. at 12 V)*4 Eco on mode: 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V)*4 Eco on mode: 950 mW or less (38 mA max. at 24 V, 47 mA max. at 12 V)*4 Eco Full mode: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V) Eco Full mode: 600 mW or less (24 mA max. at 24 V, 29 mA max. at 12 V) Operating ambient luminance Incandescent lamp: 20000 lux or less; Sunlight: 30000 lux or less Operating ambient temperature Environmental resistance -20 to +55 °C -4 to +131 °F (no freezing)*5 Operating ambient humidity 35 to 85% RH (no condensation) Vibration resistance 10 to 55 Hz Compound amplitude 1.5 mm 0.06", 2 hours for each of X,Y,Z axis 500 m/s2 3 times for each of X,Y,Z axis Shock resistance Case material Weight – Both main unit and expansion unit housing material: Polycarbonate Approx. 75 g Approx. 45 g Approx. 22 g Approx. 22 g Approx. 80 g Approx. 70 g Approx. 22 g Approx. 22 g Approx. 75 g *1 Use a cable length of 30m (98.43') or less for M8 connector types. *2 FS-N11MN only *3 SUPER: 1.2 ms, ULTRA: 1.8 ms, MEGA: 4.2 ms *4 Increases 100 mW (4.0 mA) for High Speed mode *5 One or two more units connected: -20 to +55°C (-4 to +131°F); 3 to 10 more units connected: -20 to +50°C (-4 to +122°F); 11 to 16 more units connected: -20 to +45°C (-4 to +113°F). When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting. 24 Digital Fiber Sensor FS-N Series > Specifications Input and Output Circuit Diagra ms FS-N11N / N12N / N11MN / N13N / N14N Input Circuit Diagram (FS-N13N/N14N only) Device with input impedance 10 kΩ or more Orange Load Black*3 (Control output) 5-30VDC *1 FS-N11N/N11MN/N13N only 3.3VDC 12-24VDC Brown*1 Monitor output (1-5 V)*2 Sensor main circuit Protection circuit Sensor main circuit Overcurrent protection circuit Output Circuit Diagram *2 FS-N11MN only Pink (Short-circuit current 1 mA or less) *3 The FS-N13N/N14N has a white cable as separate output 2. PLC, etc. Blue*1 0V 0V Blue*1 FS-N11P / N12P / N13P / N14P / N13CP / N14CP Input Circuit Diagram (FS-N13P/N14P only) Brown c* 12-24VDC 1 Black f*2 Load (Control output) Blue e*1 12-24VDC Brown*1 Sensor main circuit Overcurrent protection circuit Sensor main circuit Output Circuit Diagram PLC, etc. (Short-circuit current 2 mA or less) 0V 2 4 M8 connector pin layout 1 3 *1 FS-N11P/N13P/N13CP only *2 The FS-N13P/N14P has a white cable as separate output The FS-N13CP/N14CP has pin d as separate output 2. Pink FS-N11CN / N12CN Output Circuit Diagram Input Circuit Diagram 2 4 f Load 5-30VDC e* M8 connector pin layout 3.3VDC 12-24VDC Sensor main circuit Overcurrent protection circuit Sensor main circuit c* d (Short-circuit current 1 mA or less) 1 3 * FS-N11CN only PLC, etc. e* 0V 0V FS-N11CP / N12CP Output Circuit Diagram Input Circuit Diagram 2 4 c* e* Sensor main circuit Overcurrent protection circuit Sensor main circuit f Load 12-24VDC c* 12-24VDC 0V M8 connector pin layout 1 3 * FS-N11CP only PLC, etc. (Short-circuit current 2 mA or less) d Socket Cable (sold separately) For FS-N11CN / N11CP / N12CN /N12CP / N13CP / N14CP Pin – wire color OP-73864 (Cable length: 2 m 6.56') OP-73865 (Cable length: 10 m 32.81') 2 4 1 3 Connected pin number Core wire cover color c Brown d White e Blue f Black Digital Fiber Sensor FS-N Series > Circuits 25 D ime nsions Unit: mm inch FS-N11N / N11P / N13N / N13P / N11MN FS-N12N / N12P / N14N / N14P Main unit (lead wire type) Expansion unit (lead wire type) ø3.9 ø0.15", 3-core x Brown/Blue/Black: 0.34 mm2* ø2.6 ø0.10", 1-core x Black: 0.34 mm2 *1 Cable length: 2 m 6.56' Cable length: 2 m 6.56' 0.39" 9.8 0.39" 9.8 MAX 170° (Maximum when the cover is opened) 100 3.94" (Maximum when the cover is opened) 100 3.94" 0.16" 4 3.4 0.13" 0.16" 4 30.3 1.19" (35.3) (1.39") 6.7 0.26" End unit 25.4 1.00" Rear of mounting bracket 2-ø3.4 ø0.13" Spot facing: ø6.4 ø0.25", d=2.7 0.11" 2-(4.4 x 3.4)(0.17" x 0.13") Spot facing: ø7.2 ø0.28", d=3.2 0.13" 9.8 0.39" 15 0.59" 31 1.22" 26 35.4 1.39" 71.8 2.83" *1 FS-N14N/N14P: ø3.9 ø0.15", 3-core x Black/White/Pink: 0.18 mm2 *2 FS-N14N/N14P: min. 8 0.32" min. 7 0.28"*2 End unit (OP-26751 sold separately) End unit *1 0.24" 6 (38.5) (1.52") (17.3) (0.68") 25.7 1.01" 20.7 0.82" When several units are connected 30.3 1.19" 6.5 0.26" (13) (0.51") 6.7 0.26" 35.4 1.39" When the mounting bracket is attached (OP-73880 sold separately) 22.9 0.90" (35.3) 30.3 (1.39") 1.19" (13) (0.51") 20.7 0.82" 71.8 min. 8 0.32" 2.83" * FS-N11MN: ø3.9 ø0.15", 4-core x Brown/Blue: 0.34 mm2 Black/Orange: 0.18 mm2 2 FS-N13N/N13P: ø3.9 ø0.15", 5-core x Brown/Blue: 0.34 mm Black/White/Pink: 0.18 mm2 3.8 0.15" 3.4 0.13" Number of units 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L (mm inch) 9.8 0.39" 19.6 0.77" 29.4 1.16" 39.2 1.54" 49.0 1.93" 58.8 2.32" 68.6 2.70" 78.4 3.09" 88.2 3.47" 98.0 3.86" 107.8 4.24" 117.6 4.63" 127.4 5.02" 137.2 5.40" 147.0 5.79" 156.8 6.17" 166.6 6.56" 6 L 6 0.24" 0.24" *1 When using expansion units, be sure to use the end unit. (Optional) DIN-rail mounting (22.6) 20.8 (0.89") 0.82" 9.2 0.36" 53.8 2.12" 35.4 1.39" Unit: mm inch FS-N11CN / N11CP / N13CP FS-N12CN / N12CP / N14CP Main unit (M8 connector type) Expansion unit (M8 connector type) 0.39" 9.8 ø8.6 ø0.34" 0.39" 9.8 ø8.6 ø0.34" MAX 170° (Maximum when the cover is opened) 100 3.94" 0.16" 4 3.4 0.13" 30.3 1.19" (35.3) (1.39") 6.7 0.26" 71.8 2.83" OP-73864 OP-73865 2 6.56' (15.5)(0.61") 6.7 0.26" M8 0.32" connector 35.4 1.39" (26.7) (1.05") 10 6.56' Rear of mounting bracket M8 0.32" connector 9.5 0.37" L When several units are connected End unit (OP-26751 sold separately) End unit *1 End unit 6.5 0.26" 25.4 1.00" 35.4 1.39" ø3.7 ø0.15", 4 -core x 0.28 mm2 0.24" 6 30.3 1.19" (38.5) (1.52") (18.8) (0.74") 22.9 0.90" 25.7 1.01" 71.8 2.83" ø9.5 ø0.37" When the mounting bracket is attached (OP-73880 sold separately) 3.8 0.15" 20.7 0.82" 9.5 0.37" M8 socket cable (separately sold option) L (m foot) 30.3 (35.3) 1.19" (1.39") (15.5)(0.61") 20.7 0.82" Cable length 3.4 0.13" (Maximum when the cover is opened) 100 3.94" 0.16" 4 Number of units 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2-ø3.4 ø0.13" Spot facing: ø6.4 ø0.25", d=2.7 0.11" 2-(4.4 x 3.4)(0.17" x 0.13") Spot facing: ø7.2 ø0.28", d=3.2 0.13" 9.8 0.39" 15 0.59" 31 1.22" 6 0.24" L L (mm inch) 9.8 0.39" 19.6 0.77" 29.4 1.16" 39.2 1.54" 49.0 1.93" 58.8 2.32" 68.6 2.70" 78.4 3.09" 88.2 3.47" 98.0 3.86" 107.8 4.24" 117.6 4.63" 127.4 5.02" 137.2 5.40" 147.0 5.79" 156.8 6.17" 166.6 6.56" DIN-rail mounting (22.6) 20.8 (0.89")0.82" 35.4 9.2 0.36" 53.8 1.39" 2.12" 6 0.24" *1 When using expansion units, be sure to use the end unit. (Optional) Digital Fiber Sensor FS-N Series > Dimensions 27 New! Improved FIBER CUTTER Leaves a clean cut edge which prevents uneven light intensity. The new cutter comes with the FS-N Series (amplifier). The cutter included with the fiber unit will be phased out from the old type to the new type. Once the changeover is complete, cutters will no longer be included with amplifier units. Current design NEW OP-0237 OP-87098 CALL TOLL FREE T O C O N TA C T Y O U R L O C A L O F F I C E 1-888-KEYENCE 1 - 8 8 8 - 5 3 9 - 3 6 2 3 KEYENCE CORPORATION OF AMERICA Corporate Office 50 Tice Blvd., Woodcliff Lake, NJ 07677 ■ Regional offices AL Birmingham CA N.California CA Los Angeles CO FL GA IL Denver Tampa Atlanta Chicago IN KS KY MA Indianapolis Kansas City Louisville Boston MI MI MN MO Please read the instruction manual carefully in order to safely operate any KEYENCE product. PHONE: 201-930-0100 Fax: 201-930-0099 E-mail: keyence@keyence.com Detroit Grand Rapids Minneapolis St. Louis NJ NY NC NC KEYENCE CANADA INC. Head Office PHONE: 905-696-9970 Fax: 905-696-8340 Montreal PHONE: 514-694-4740 Fax: 514-694-3206 SAFETY INFORMATION www.keyence.com Woodcliff Lake Rochester Charlotte Raleigh OH OH OR PA Cincinnati Cleveland Portland Philadelphia SC TN TN TX Greenville Nashville Knoxville Dallas Richmond Seattle VA WA KEYENCE MEXICO S.A. DE C.V. E-mail: keyencecanada@keyence.com PHONE: +52-81-8220-7900 Fax: +52-81-8220-9097 E-mail: keyencemexico@keyence.com KEYENCE GLOBAL HEADQUARTERS 1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: +81-6-6379-2211 KA1-1010 The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice. Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved. FSN-KA-C-E 1030-2 611307 Printed in Japan * 6 1 1 3 0 7 *
Similar documents
MSR Newsletter - September 1975
After that one healed, I used moleskin on the entire heel and up the back two inches, cut at the corners to form a heel cup. That helped, but I finally went to a full coverage of the bottom of my f...
More informationNURSING HOME BOARD OF DIRECTORS AGENDA
revenue totaled $41 9k, which was over budget by S3 1k. Medicaid revenue was 5520k, which was over budget by $97k.Medicare revenue was $ 150k, and was under budget by S 143k. Medicare Part B revenu...
More information