Bi-Wire Fire System

Transcription

Bi-Wire Fire System
cfs0038_R1_Bi-Wire-4-page-leaflet_Layout 1 26/05/2011 15:26 Page 1
Bi-Wire Fire System
Dual LED Indicator
Saves both time and cost
No requirement for separate
sounder circuits
Zone 1
Zone 2
Zone 3
Zone 4
• BS5839 Part 6 HMO
compliant (4 & 8 zone)
• Multi-Mode detector
• ‘Self-Check’ technology
• Improved functionality
• Significant cost saving
Cooper Patented Technology
Bi-Wire UK Patent: GB2293257
Self-Check European Patent: EP:02253889.6
cfs0038_R1_Bi-Wire-4-page-leaflet_Layout 1 26/05/2011 15:26 Page 2
Bi-Wire Control Panels FX2200BW Range
Overview
Benefits
The patented ‘Self-Check’ technology,
integrated into the range of Bi-Wire
panels, gives the panels the facility to
flash all detector LED’s in a specified
zone to indicate the location of any
wiring fault in that zone, thereby
simplifying the fault finding process.
• BS5839 Pt 1 & 6
4 & 8 zone panel
The 4 and 8 zone panels within the range
now provide enhanced features, which
include a HMO facility on each zone via a
discreet DIP switch. If a zone has been
programmed for HMO operation, any fire
occurring within that zone will activate the
zone fire LED and only the sounders within
that zone. Providing the fire condition and
affected detector smoke chamber is
cleared within 2 minutes, the panel will
reset automatically. If no reset occurs, the
sounders, strobes and relays will be
activated on all zones.
• Supports up to 20
detectors and 20 outputs
(sounders, LED beacons
and relay modules)
per zone
• Time saving simplified
fault finding procedure
• The only conventional
panel with ‘Internal’
detector fault monitoring
• Weekly ‘end user’ test
• Simple panel installation
• Reduced wiring
requirements provide
savings in both
installation and cost
Bi-Wire Repeater Panel FXRP2200BW
Overview
Benefits
The Bi-Wire range repeater panel provides
a quick, cost effective method of providing
system status information in key areas
remote from the main control panel. It is
available for connection to the 4 & 8 zone
Bi-Wire control panels.
• Matches the main panel
• Requires only a single
pair of wires to receive
signals from main panel,
plus local mains power
supply, reducing cost of
installation
• Displays essential
information at other key
locations:
- Zone fire and fault
conditions
- Test mode in operation
- Zones or outputs in
disabled mode
cfs0038_R1_Bi-Wire-4-page-leaflet_Layout 1 26/05/2011 15:26 Page 3
Bi-Wire Multi-Mode Detector FXN922
Solid Amber LED
Is continuous to indicate
smoke sensing
chamber fault or the
detector has
reached its limit of
contamination
Flashing Amber LED
Can also be pulsed from
the panel to help
locate wiring faults
Solid Red LED
Is continuous to indicate
that the detector is in
alarm condition
Overview
Benefits
The unique Bi-Wire conventional, 5 in 1,
‘Self-Check’ detector is designed and
manufactured to provide peace of mind.
One of the major benefits of the ‘SelfCheck’ detector is it’s ability to inform the
end user when a detector has ceased to
function correctly or indeed has failed.
5 modes that are simple
to configure:
• Optical
• Optical/heat
• Heat detector
(1 of 3 modes)
The detector has been designed to monitor
itself for any internal fault condition or
failure. Should a problem be detected, a
zone fault will be generated at the panel
and the detector LED will light (amber
segment) indicating both zone and device.
To aid contractors and service providers
detectors in all zones can be instructed,
from the panel, to pulse their LED (amber
segment) every 2 seconds. This facility can
then be used help to locate wiring faults on
a zone’s wiring thereby saving both time
and labour.
- Rate of rise (A1R)
- Fixed 77° (BS)
- Fixed 92° (CS)
‘The only conventional detector to talk to the panel’
Bi-Wire Starter Kits FX2ZBWKIT / FX4ZBWHMOKIT
Everything you need for a system installation
2 Zone Bi-Wire Kit
4 Zone Bi-Wire Kit
• 1 x 2 Zone Panel
• 1 x 4 Zone Panel
• 6 x Detectors
• 10 x Detectors
• 4 x Bases
• 6 x Bases
• 2 x Sounder Bases
• 4 x Sounder Bases
• 2 x Callpoint
• 4 x Callpoint
e Kit
4 Zon
laint
Comp
HMO
cfs0038_R1_Bi-Wire-4-page-leaflet_Layout 1 26/05/2011 15:26 Page 4
Product Codes
Bi-Wire Accessories
Bi-Wire Control Panels
Callpoints
FX2202BW
2-Zone Panel
• ‘Quick-Fit’ clip-fixed front cover
FX2204BWHMO
4-Zone Panel
• One key for test and cover removal
FX2208BWHMO
8-Zone Panel
Bi-Wire Repeater Panel
Electronic Sounders
FXRP2200BW
• Ultra low current
Repeater Panel
Detectors and Detector Bases
• High sound output
FXN922
Multi-Mode Detector
• Volume control
FXN520
Standard Base
• Lockable base
FXN521BWS
Sounder Base
FXN521BWB
Beacon Base
FXN521BWSB
Sounder Beacon Base
FXN538COV
Cover for Bases
• Low current
FX201
Flush/Surface Callpoint
• Can be used as a stand-alone
sounder, beacon or sounder beacon
FX203
Weatherproof Callpoint
CXPC
Plastic Front Cover (Pk of 10)
FX5G
Spare Glasses (Pk of 5)
FX009
Wall Sounder
FXN004BW
LED Beacon
• High output LED beacon
FXN01124V
24V dc Relay Module
• Low current
FXN011230
230V ac Relay Module
Relay Modules
Accessories
Detector Bases
• Integrated detector base
• With detector fitted, one location for
detection and alarm output
LED Beacon
Bi-Wire Starter Kits
FX2ZBWKIT
Bi-Wire 2 Zone Starter Kit
FX4ZBWHMOKIT
Bi-Wire 4 Zone Starter Kit
• Connects on zone wiring
• Relay operates on any fire activation
Cooper Safety Fire Systems
Cooper Lighting and Safety Ltd, Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NB.
www.cooperfire.com
Sales
T: +44 (0)1302 303 999
F: +44 (0)1302 303 333
E: sales@cooperfire.com
Technical and Quotations
T: +44 (0)1302 303 350
F: +44 (0)1302 303 332
E: techsupport@cooperfire.com
®2010 Cooper Lighting and Safety. All rights reserved. Publication reference: CFS0038-BW4
Export
T: +44 (0)1302 303 344
F: +44 (0)1302 303 345
E: export@cooperfire.com
Awarded to: