C:\Tech Manuals\EZREMOTE\EZREMOTEWPD

Transcription

C:\Tech Manuals\EZREMOTE\EZREMOTEWPD
EZ-REMOTE
TEST PLATFORM
REFERENCE MANUAL
Warranty Registration
Thank you for purchasing the EZ-REMOTE® DS1/DS3/SONET test platform.
To provide complete service on this product, we must have a record of warranty
registration. Please take a few moments to complete the warranty registration card
in the back of this manual and MAIL IMMEDIATELY. There are also two change of
address cards that can be used as required.
Trademarks Referenced in this Manual
“EZ-REMOTE”, “EZ-TESTER” and “LIGHT-MATE” are trademarks of Electrodata, Inc.
Electrodata, Inc.
23020 Miles Road
Bedford Heights, Ohio 44128-5400
Phone: 216-663-3333
Toll Free: 800-441-6336
FAX: 216-663-0507
www.electrodata.com
Part No.610069 - December 2005
© 2005 Electrodata, Inc.
(This page intentionally left blank)
GETTING STARTED
This manual describes the Electrodata DS1/DS3/SONET EZ-REMOTE® Test Platform. We assume
the operator has some familiarity with DS1, DS3, SONET and ATM circuit conventions and terminology.
To become fully acquainted with the features of the EZ-REMOTE®, we recommend that the
operator read the LIGHT-MATE® manual as well as the applicable portions of the operating manual for
the EZ-TESTER® ST. Since operation of the LIGHT-MATE® and EZ-TESTER® ST is relatively
straightforward, you will be able to perform many tests by turning to Operation in Chapter 2 of both
manuals and reading the step-by-step procedures.
If you have questions concerning the proper operation of the EZ-REMOTE® and cannot find the
information, contact the factory by any means shown in chapter 3 of this manual.
(This page intentionally left blank)
TABLE OF CONTENTS
TABLE OF CONTENTS
Chapter/Paragraph
Page
GETTING STARTED
LIST OF ILLUSTRATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
1
INTRODUCTION
1.1
1.2
1.3
1.4
1.5
2
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1-1
1-1
1-1
1-2
1-2
OPERATION
2.1
2.2
2.3
3
General . . . . . . . . . . . . .
Functional Description . .
Physical Description . . . .
Receiving and Unpacking
Accessories . . . . . . . . .
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
XPort DeviceInstaller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
EZ-REMOTE Computer Enhanced Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
MAINTENANCE
3.1
3.2
3.3
3.4
3.5
EZ-REMOTE Warranty . . . . . .
Routine Maintenance . . . . . . .
Cleaning the Cooling Fan Filters
Self-Test Procedure . . . . . . . .
Factory Service . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3-1
3-1
3-1
3-1
3-2
i
TABLE OF CONTENTS
Figure
1-1
1-2
2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
2-9
2-10
2-11
2-12
2-13
2-14
2-15
2-16
2-17
2-18
2-19
2-20
2-21
2-22
LIST OF ILLUSTRATIONS
Title
Page
EZ-REMOTE FRONT PANEL VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-0
EZ-REMOTE REAR PANEL VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-0
DEVICE INSTALLER SEARCH Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
DEVICE INSTALLER SEARCH (Unit Selected) Screen . . . . . . . . . . . . . . . . . . . . . . . . 2-2
DEVICE INSTALLER ASSIGN METHOD Screen . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
DEVICE INSTALLER IP SETTINGS Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
DEVICE INSTALLER ASSIGNMENT Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
DEVICE INSTALLER ASSIGNMENT COMPLETED Screen . . . . . . . . . . . . . . . . . . . . 2-4
DEVICE INSTALLER SEARCH DISPLAY Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
DEVICE INSTALLER PING DEVICE Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
DEVICE INSTALLER CONFIGURE PORT SETTINGS Screen . . . . . . . . . . . . . . . . . . 2-6
DEVICE INSTALLER PORT PROPERTIES Screen . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
DEVICE INSTALLER ADVANCED CONNECTION PROPERTIES Screen . . . . . . . . . . . 2-8
EZ-REMOTE TTS3 LINK DOWN DISPLAYED Screen . . . . . . . . . . . . . . . . . . . . . . 2-10
EZ-REMOTE COMMUNICATIONS SETTINGS Screen . . . . . . . . . . . . . . . . . . . . . 2-10
EZ-REMOTE TESTING Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
EZ-REMOTE POWER DOWN Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
EZ-REMOTE LINK DOWN DISPLAYED Screen . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
EZ-REMOTE TCP/IP LINK CONNECTED DISPLAYED Screen . . . . . . . . . . . . . . . . 2-13
EZ-REMOTE SELF-TEST PASSED DISPLAYED Screen . . . . . . . . . . . . . . . . . . . . . 2-13
EZ-REMOTE TESTING Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
EZ-REMOTE FULL SELF-TEST Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
EZ-REMOTE FULL SELF-TEST RESULTS Screen . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
EZ-REMOTE TESTING Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
LIST OF TABLES
Number
1-1
ii
Title
Page
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
TABLE OF CONTENTS
(This page intentionally left blank)
iii
INTRODUCTION
Figure 1-1. EZ-REMOTE® FRONT PANEL VIEW
Figure 1-2 EZ-REMOTE® REAR PANEL VIEW
INTRODUCTION
1.1 General
The EZ-REMOTE® test platform shelf incorporates the same features and capabilities as the
combination of the EZ-TESTER® ST (STS-1 SONET test set) and the LIGHT-MATE I (LM-1) OC3/OC12
lid. The EZ-REMOTE is controlled through a LAN 10Base-T/100Base-T Ethernet connection. Optical
testing is performed using a laser signal source plus an optical receiver for monitoring customer or test
signals. FC type RX and TX optical connectors are provided for the SONET OC3/OC12 test access.
STS-1, DS3, DS1 and DS0 signals can be dropped and inserted for testing from an OC12 or OC3 signal
at the optical test access point. BNC RX, TX and EXT connectors are provided for STS-1/DS3 test
access. DS1 and DS0 signals can be dropped and inserted for testing from a STS-1 or DS3 level signal
via the STS-1/DS3 test access point. Bantam RX, TX and REF jacks are provided for DS1 test access.
DS0 signals can be dropped and inserted for testing from a DS1 level signal via the DS1 test access
point.
The EZ-REMOTE® shelf incorporates the following design features:
•
•
•
•
•
•
•
Rugged metal case approximate dimensions (17"W X 15 1/4"L X 3 1/4"D)
Mounts in a standard 19" EIA rack or a 23" EIA rack with adapters.
Windows Based Graphic User Interface for ease of use.
Operates at 1310nm wavelengths (OC3/3C and OC12/12C).
Auto configuration feature determines line characteristics and reduces setup time.
Includes stored test patterns and programmable byte vital to SONET testing.
Enables STS-1, DS3, DS1, and DS0 channel access from any of the higher order transport.
1.2 Functional Description
The EZ-REMOTE® incorporates the same features as the combination of the EZ-TESTER ST
equipped with the LIGHT-MATE I lid. Comprehensive testing can be accomplished at the OC12/12C,
OC3/3C, STS-1, DS3, DS1 and DS0 transport levels. A complete description of the EZ-REMOTE®
functions, capabilities and specifications is contained in the EZ-TESTER ST and LIGHT-MATE manuals.
1.3 Physical Description
The EZ-REMOTE® is housed in a rugged metal case. The approximate dimensions are: 17"W X
15 1/4"L X 3 1/4"D. The EZ-REMOTE® mounts in a standard 19" EIA rack or a 23" EIA rack with
adapters. All the test access jacks are located on the rear panel. Test access for OC3/OC12 signals
is accomplished through FC (standard) or ST (optional) RX and TX jacks located on the left side of the
rear panel. Test access for STS-1/DS3 signals is accomplished through RX, TX and EXT BNC jacks
located near the middle left of the rear panel. Test access for DS1 signals is accomplished through RX,
TX and REF bantam jacks located near the middle right of the rear panel.
Operational control of the EZ-REMOTE® is performed using the Computer Enhanced Testing
(CET) graphical user interface Widows® based software. Access is provided via a 10BaseT/100BaseT
LAN RJ45 jack located on the right side of the rear panel.
Power to the EZ-REMOTE® is provided through a 110VAC male connector located on the right
side of the rear panel.
1-1
INTRODUCTION
A POWER indicator LED is mounted on the left front and right rear panel of the EZ-REMOTE.
Additional LEDs mounted on the rear panel indicate receive OC3/OC12 PULSES, LASER ON, receive
STS1/DS3 PULSES and receive DS1 PULSES.
A small cooling fan is mounted on the right side of the rear panel that draws air through a
filtered circular vent mounted on the left side of the rear panel.
1.4 Receiving and Unpacking
The EZ-REMOTE should be unpacked when received and visually inspected for any damage.
If the assembly appears to be damaged and the outside of the shipping container is damaged, contact
the carrier and submit a claim. The serial number, located on the metal tag on the left side of the rear
panel, should correspond with the packing list. If any problems are noted, contact the factory.
Each EZ-REMOTE has an unique hardware (MAC) hardware address associated with it. This
address is located on the bottom of the rear panel and should be recorded for installation reference. This
address is needed for the XPort DeviceInstaller program to assign an IP address on the user’s network
1.5 Accessories
Table 1-1 lists the accessories.
Table 1-1. EZ-REMOTE ACCESSORIES
Part No.
Provided with the EZ-REMOTE
600010
6FT 110VAC Power Cord
610069
EZ-REMOTE Reference Manual
610068
LIGHT-MATE Operating Manual
610064
EZ-TESTER ST Operating Manual
Part No.
Available at Additional Cost for the EZ-REMOTE
600087
FC to ST Optical Patch Cord
600088
FC to SC Optical Patch Cord
600086
FC to FC Optical Patch Cord
600041
Bantam to Bantam DS1 Patch Cord, 5FT
1-2
OPERATION
2.1 General
This chapter describes the installation and use of the XPort DeviceInstaller and the Electrodata
Computer Enhanced Testing software packages.
2.2 XPort DeviceInstaller
The XPort DeviceInstaller is necessary to assign an IP address to the EZ-REMOTE® unit’s
hardware address (also known as a MAC address). The MAC address is located on the bottom of the
rear panel of the EZ-REMOTE, in the format: 00-20-4a-XX-XX-XX, where the XXs are unique numbers
assigned to the unit. You will need to know the assigned IP address and the Local Port. The Systems
Administrator usually provides this information. The Subnet mask is assigned automatically based on
the IP address; if desired you can change it. You can leave the Default gateway blank (all zeros) on a
local network.
The following is the procedure to install the Xport DeviceInstaller, assign the IP address and
configure the EZ-REMOTE serial port settings.
Install the DeviceInstaller
1. Insert the Electrodata Software And Product Information disk into your CD drive.
a. After the CD automatically launches and the introduction is finished, the
Electrodata home page is displayed. Click on the “Software Updates” button.
b. On the “Downloadable Firmware and Software” page, scroll down to the XPort
DeviceInstaller (bottom of page) and download.
2. Respond to the installation wizard prompts.
Assign IP
The EZ-REMOTE unit’s default IP address is set to 192.168.1.125 at the Electrodata
factory. The hardware (MAC) address is located on the bottom of the rear panel of the
EZ-REMOTE.
1.Verify that the EZ-REMOTE is connected to a live 110VAC outlet. The POWER LEDs
will not light until the unit is powered on remotely. (Page 2-11, Step 3)
2.Connect one end of an Ethernet cable to the LAN RJ45 connecter located on the right
side of the rear panel of the EZ-REMOTE unit. Connect the other end of the Ethernet
cable to your network hub. The LAN connector left status LED should light to verify
a connection. Connect and install only one at a time when turning up multiple units.
3. Click Start>Programs>Lantronix>DeviceInstaller>DeviceInstaller. If your PC has
more than one network adapter, a message will display. Select an adapter and click
OK. You can install a shortcut on the Windows desktop for ease of use.
4. Click on the Search icon and select the EZ-REMOTE unit from the EZ-REMOTE unit
from the list of device servers on the local network. When installing multiple EZREMOTE units, you must connect and install one at a time since all the default IP
addresses are the same: 192.168.1.125. (Figure 2.1)
2-1
OPERATION
Figure 2.1
5. Select the unit from the list and click the Assign IP icon. (Figure 2.2)
Figure 2.2
2-2
OPERATION
6. Choose Assign a specific IP address and click Next. (Figure 2.3)
Figure 2.3
7. Enter the IP address. The Subnet mask displays automatically based on the IP
address; if desired, you may change it. On a local network, you can leave the
Default gateway blank (all zeros). Click NEXT. (Figure 2.4)
Figure 2.4
2-3
OPERATION
8. Click on Assign. Wait several seconds until complete. (Figure 2.5)
Figure 2.5
9.Click on Finish to complete the assignment. (Figure 2.6)
Figure 2.6
2-4
OPERATION
10. The Search display with the completed IP assignment. (Figure 2.7)
Figure 2.7
11. Select the newly assigned device and click Tools>Ping. Click the Clear Status
button to clear the window to ping the device again. Click on Close. (Figure 2.8)
Figure 2.8
2-5
OPERATION
Configure Port Settings
This procedure is to configure the XPort device serial port settings. The port settings
are: Serial Protocol=RS232, Speed=19200, Character Size=8, Parity=None
StopBit=1, Flow Control=Hardware.
1. On the main screen, select the device and click on the Configure icon. On the
Configure Device screen, click on the Ports tab. Continue with this procedure even
if the settings are correct. (Figure 2.9)
Figure 2.9
2. Click on the Edit Settings button. (Figure 2.9)
2-6
OPERATION
3. On the Port Properties screen, use the drop down choices to change the settings if
necessary. Then click on the Advanced tab. (Figure 2.10)
Figure 2.10
2-7
OPERATION
4. On the Advanced Port Property screen, verify the Serial Settings are correct. In
the Passive Connection section, the Local Port value should be provided by your
System Administrator. The default value is 101. All of the other remaining settings
can be left at the default values (Figure 2.11)
Figure 2.11
5. To change the Local Port value, highlight it and over type the new value. Click on
OK. The Configure Device screen will appear.(Figure 2.09)
6. On the Configure Device screen, click on Apply and then OK.
7. The Main screen will appear. Close the Main screen.
8. The XPort DeviceInstaller procedure is complete.
2-8
OPERATION
2.3 EZ-REMOTE Computer Enhanced Testing
EZ-REMOTE® Computer Enhanced Testing software allows the user to operate the EZ-REMOTE
from a PC running with Microsoft Windows® via an Ethernet connection. The graphical features,
interfaces, and operations used in this Windows-based application program follow the standard format
found in all other Windows applications programs. These procedures assume that you are experienced
in running Microsoft application programs, and have read and understand chapters 1 and 2 of the EZTESTER ST OPERATING MANUAL and chapters 1 and 2 of the LIGHT-MATE OPERATING MANUAL.
Both of these manuals are supplied with the EZ-REMOTE.
The EZ-REMOTE Windows software is supplied on the Electrodata Software And Product
Information CD. The program follows the operations and graphics familiar to all Windows applications
users.
Install the EZ-REMOTE Windows Testing Software
1. Insert the Electrodata Software And Product Information disk into your CD drive.
a. After the CD automatically launches and the introduction is finished, the
Electrodata home page is displayed. Click on the “Software Updates” button.
b. On the “Downloadable Firmware and Software” page, scroll down to the
Windows Software section and click on the EZ-TESTER ST download.
2. Respond to the installation wizard prompts.
EZ-REMOTE Computer Enhanced Testing Program
For first time use it is advisable to verify the EZ-REMOTE unit is connected to a live
110VAC outlet and the Ethernet cable is connected. Also, check the status of the two
indicator LEDs located on the LAN connector. The LED on the left (lighted) indicates a
connection: Amber= 10Mbps and Green= 100Mbps. The LED on the right (on and
off at random intervals) indicates activity: Amber= Half-Duplex and Green= Full
Duplex.
1. Click Start>Programs>Electrodata>Electrodata EZ-Tester ST. The WinTTS3-EZ EZREMOTE program opens. You can install a shortcut on the Windows desktop for
future use. (Figure 2.12)
2. Click on Options and then Serial Port. On the Communications Settings screen, in the
Com Port drop down list, choose TCP/IP. The Terminal Echo setting is Off. Type your
assigned IP address in the Address field and your assigned port number in the Port
Field. Click on OK. (Figure 2.13)
2-9
OPERATION
Figure 2.12
Figure 2.13
2-10
OPERATION
3. While establishing the connection, the box in the upper left corner of the screen
will briefly display “TCP/IP Link Connected”. The connection to the unit is
established. (Figure 2.14)
Figure 2.14
4. Verify that the EZ-REMOTE unit can power down by clicking on the PWR button. A
pop-up window will appear asking if you really want to. Click on Yes. (Figure 2.15)
Figure 2.15
2-11
OPERATION
5. When the unit is powered down the message box in the upper left corner of the
screen will display “TTS 3 Link Down”. (Figure 2.16)
Figure 2.16
6. Verify that the unit can be powered up and pass the power on self test by clicking
on the PWR button. The message box in the upper left corner briefly displays the
following messages: “TCP/IP Link Connected” and “Self-Test Passed”. If the unit
fails the power on self test, the message box will briefly display “Self-Test Failed”.
The message box turns blank when the connection is made. (Figures 2.17, 2.18
and 2.19)
2-12
OPERATION
Figure 2.17
Figure 2.18
2-13
OPERATION
Figure 2.19
7. On a newly installed unit it is recommend to perform a Full Self-Test. Click on the
Main button if necessary to display the Main menu. Select FULL SELF-TEST and
place patch cords to loop the unit as indicted in pop up box below. Click on
Continue. (Figure 2.20)
Figure 2.20
2-14
OPERATION
8. A pop up box will indicate the progress and status the test. Click on Close when
the test is complete. (Figure 2.21)
Figure 2.21
9. Remove the looping cords and connect to the appropriate test access ports as
required. The EZ-REMOTE unit is ready for testing purposes using the Graphical
User interface screen. (Figure 2.22)
Figure 2.22
2-15
OPERATION
10. Testing is accomplished by choosing a test function on the menu located the
lower left of the screen. Visual indicators display the presence of pulses, alarms,
BPVs, errors, loss of signal and other circuit conditions. Specific results can be
viewed choosing a category from the drop down menu located on the lower right
of the screen.
11. If you need any assistance with the software installation or the operation of your
EZ-REMOTE, contact Electrodata by any means listed below.
Electrodata, Inc
23020 Miles Road
Bedford Heights, Ohio 44128-5400
Telephone:
Toll Free:
Fax:
E-mail:
2-16
216-663-3333
1-800-441-6336
216-663-0507
testsets@electrodata.com
MAINTENANCE
3.1 EZ-REMOTE Warranty
The EZ-REMOTE is warranted to be free of defects in material and workmanship for a period
of three (3) years from date of shipment to the original purchaser. During the warranty period,
Electrodata, Inc. will, at its option, either repair or replace your EZ-REMOTE if it proves to be defective
due to material or workmanship.
Electrodata, Inc. will pay the inbound and out-bound freight charges to return your EZ-REMOTE
to the factory for warranty service, providing you obtain a RETURN MATERIAL AUTHORIZATION (RMA)
number and ship in accordance with instructions from Electrodata, Inc.
The EZ-REMOTE warranty does not apply to defects resulting from misuse or abuse; to dents
and scratches to the cover, case, or front panel; or to field repairs or modifications not performed by,
or approved in writing by Electrodata, Inc.
Electrodata, Inc. shall not be liable for damages greater than the cost or replacement value of
the EZ-REMOTE.
3.2 Routine Maintenance and Testing
The EZ-REMOTE is a highly reliable solid state device that requires no adjustment. The only
routine maintenance required is the periodic cleaning of the fan filter as described in paragraph 3.3.
In case of problems with the test set, the self-test programs described in paragraph 3.4 should
be run to verify that the LM is operational. If the LM is found to be non-operational, it should be
returned to the factory for repair. Return authorization and shipping instructions must be obtained from
the factory before returning the test set. A note indicating the suspected failure or symptoms and
return address should be included with the unit when shipped.
3.3 Cleaning the Cooling Fan Filter
During operation, the EZ-REMOTE circuitry generates sufficient heat to require a cooling fan.
The fan is mounted on the right side of the rear panel and exhausts air through a filtered circular vent.
Intake air is drawn through a circular vent with a sponge filter mounted on the left side of the rear
panel. The filters must be kept free of debris buildup or heat damage to the LM may occur.
Clean the filters as required using a standard vacuum cleaner and hose applied over the black
filter retaining disk. If working conditions are such, more frequent cleaning may be required. Do not
reverse the operation of the vacuum cleaner or the filter may be blown into the EZ-REMOTE circuitry
and protection from debris will be lost.
The filters can be replaced by snapping out the plastic grills in front of them with a flat blade
screwdriver.
3.4 Self-Test Procedure
The EZ-REMOTE is designed to perform a short power-on self-test that runs each time the test
set is turned on. In addition to it’s own test, the self-test operation will perform tests on the unit to
confirm normal operation. The EZ-REMOTE is designed with a comprehensive FULL SELF-TEST that
can be run by selecting FULL SELF-TEST on the MAIN MENU screen.
3-1
3.5 Factory Service
Where to Get Help
If you need any assistance operating your EZ-REMOTE, or if you suspect a problem, or to inquire
about options or new features, contact either your local Electrodata representative or Electrodata by
mail, e-mail, or directly by our FAX or toll-free telephone number.
Electrodata, Inc.
23020 Miles Road
Bedford heights, Ohio 44128-5400
Telephone:
Toll Free:
FAX:
E-Mail:
216-663-3333
800-441-6336
216-663-0507
testsets@electrodata.com
Returning Your EZ-REMOTE to the Factory
When Electrodata, Inc. confirms that you need to return your EZ-REMOTE to the factory for
service, make sure that you obtain a Return Material Authorization (RMA) number. Package the test
set carefully in a shipping carton (preferably its original shipping carton), mark the RMA number on the
outside of the carton, and send it to the address shown above or as directed by factory personnel.
3-2