Vallourec USA Corporation OCTG Catalog
Transcription
Vallourec USA Corporation OCTG Catalog
Vallourec USA Corporation OCTG Catalog Vallourec USA Corporation / Introduction / pg. 1 Table of Contents Vallourec USA Corporation Disclaimer and Limits of Liability............1 Introduction............................................2 Premium Products..................................9 Premium Services.................................15 Premium Connections..........................19 Material Properties...............................31 Performance Data (Tubing)...................37 Performance Data (Casing 4 1/2” - 7")...............................41 Performance Data (Casing 7 5/8” - 10 3/4”)...............................61 Performance Data (Casing 11 3/4” - 26”)..........................81 Marking & Color Codes......................95 All information is provided by Vallourec or its affiliates at user’s sole risk, without liability for loss, damage or injury resulting from the use thereof; and on an “AS IS” basis without warranty or representation of any kind, whether express or implied, including without limitation any warranty of merchantability, fitness for purpose, accuracy or completeness. This document and its contents are subject to change without notice. In no event shall Vallourec or its affiliates be responsible for any indirect, special, incidental, punitive, exemplary or consequential loss or damage (including without limitation, loss of use, loss of bargain, loss of revenue, profit or anticipated profit) however caused or arising, and whether such losses or damages were foreseeable or Vallourec or its affiliates was advised of the possibility of such damages. pg. 2 / Vallourec USA Corporation / Introduction Vallourec USA Corporation / Introduction / pg. 3 Vallourec in North America Vallourec in North America is comprised of the following six companies: Vallourec USA Corporation, its sales entity, Vallourec Star, Vallourec Tube-Alloy, VAM USA, Vallourec Canada and Vallourec Mexico. Through the years the Vallourec Group has developed a reputation for quality products, exceptional service and constant innovation. The company’s North American steel and pipe-making operations are based in Youngstown, Ohio. The original facility within the complex boasts the latest technology in electric arc furnace (EAF) steelmaking and mandrel pipe mill (MPM) production. The new state of the art mill that came on line as of December 2012, known as the fine quality mill (FQM), offers pipe rolling, end finishing, API threading, and semi-premium threading. The integrated facility includes a steel mill, a mill specializing in medium diameter tubes (from 5” to 10-3/4”) and the new mill which specializes in the manufacture of small diameter tubes (2 3/8” to 7”). Vallourec Star and it's two mills are capable of manufacturing seamless tubular products in ODs ranging from 2-3/8” to 10-3/4”. The plant in Muskogee, Oklahoma specializes in production and inspection of high performance, proprietary, and custom casing and coupling stock in addition to API 5CT products. The Muskogee facility offers heat treatment with precise temperature control, straightening and hot sizing, finishing, hydrostatic pressure testing and premium CNC threading services up to 16". Our Muskogee mill is known for providing the industry with high performance sour service grades supported by an on-site metallurgical lab. pg. 4 / Vallourec USA Corporation / Introduction Vallourec USA Corporation / Introduction / pg. 5 Vallourec in the World The Vallourec Group is a world leading manufacturer of seamless steel tubes and specific tubular products for industrial applications. Specializing in the most complex and highly-demanding industrial applications (extreme temperatures, pressures and corrosion), notably in the energy sector, the Group offers a portfolio of diversified, unique and high value-added tubular products. Today, Vallourec is a supplier of reference throughout the world and has the major competitive advantage to offer its customers high-quality products and local services throughout the world. The Houston, Texas operations provide services such as heat treatment, straightening and hot sizing, finishing and hydrostatic pressure testing third-party inspection, 8D collapse testing, semi-premium and API threading with accessibility to VAM® premium CNC threading services. The Houston high-tech, heat-treating facility provides precise temperature control and water quenching, allowing production of high yield strength OCTG and coupling stock required for today’s critical environments. Other North American facilities include three premium threading entities: Vallourec Canada, with two locations in Canada, VAM USA with four sites between Houston, Texas and Muskogee, Oklahoma, and Vallourec Mexico based in Veracruz. Finally, Vallourec Tube-Alloy located in Houston, Texas, Houma, and Broussard, Louisiana and Casper, Wyoming, provides downhole premium accessories worldwide. Complementing the North America offer, the Vallourec Group offers a large portfolio of diversified, innovative and high value-added tubular products that comprises the world’s most extensive range of seamless tubes, with outside diameters of up to 26 inches in over 250 grades of steel. Production facilities on four continents, complemented by a worldwide network of sales offices and service centers ensure a global presence in the proximity of its customers everywhere. Its Oil & Gas Division is recognized worldwide for its commitment to extreme environment solutions. The high-tech products designed and developed by the Oil and Gas Division meet the reliability requirements of even the most demanding customers. They include drilling products, plain-end or threaded seamless tubes and casing for oil and gas production with standard API or VAM® premium connections for a variety of applications. Brief History Europe Vallourec has more than 100 years of experience and has been constantly expanding thanks to internal and external growth. One of the more important expansions was the joint-venture with Mannesmann in 1997 forming Vallourec & Mannesmann Tubes (V & M Tubes) merging all their production units and marketing interests for seamless hot-rolled tubes and threaded oilfield tubulars. In 2005, Vallourec acquired the 45% stake held by Mannesmannröhren-Werke in V & M Tubes, which is now 100%-owned by Vallourec. North America South America Africa Asia and Middle East In 2013, the Group went through a rebranding exercise worldwide and is now known simply as Vallourec. Sales Offices Steel Plants Manufacturing Plants Accessories and Repair VAM® Licensee Facilities VAM® Field Service International pg. 6 / Vallourec USA Corporation / Introduction Vallourec USA Corporation / Introduction / pg. 7 An Integrated & Competitive Process To secure complete control over the entire production process from steelmaking to shipment of the finished product, Vallourec operates three steel mills (electric steel mills in France and the United States, and an oxygen steel mill in Brazil) in addition to owning a 20% share in the HKM mill (Germany) and a 56% share in the VSB mill (Brazil). The Vallourec Group of companies produces hot-rolled seamless steel tubes in sizes ranging from 2-3/8” to 26”. Available production capacity, coupled with the competence of expert teams, enables Vallourec to accommodate production of specially formulated grades, thus creating conditions of continuing performance improvements to service the customer. Vallourec offers a full and unique range of products: API grades strength: 55 to 150 ksi. High Collapse: includes the requirements and parameters adapted to the various hostile environments which are under the highest pressures. 13% Cr & super 13% Cr: suitable for Sweet CO2 environment with limited H2S presence. It covers the requirements and parameters of such hostile conditions including high pressures, high temperatures and more. Sour Service: suitable for environments where H2S is present. It covers the requirements and parameters of such hostile conditions including high pressures, low temperatures, low pH, and more. Yield Corrosion Resistant Alloy (CRA): suitable for the more stringent corrosive environments beyond the properties of Sour Service grades. Vacuum Insulated Tubing (VIT): ideal for deepwater projects and other specialized applications including reduction of APB, heavy oil production, and steam injection. Expandable Tubing (ET): ideal for recompletions, zonal isolation and casing remediation. Riser Grade: Developed for high fatigue conditions seen in top tension riser systems with enhancements in chemistry, hardness, CTOP performance, and SSC resistance. Create, improve and promote solutions for the future Our comprehensive Research & Development policy aims to provide innovative solutions to our customers. The objective is to create, improve and promote products, services, materials and processes for the future. Suitable to actual market needs and working in close cooperation with marketing and plant teams, our R&D staff has access to substantial resources for putting this policy into effect: Over 500 employees dedicated to R&D An R&D budget of $120 million in 2013 Six research centers in four countries dedicated to OCTG product development: Germany - Vallourec Research Center Germany, Düsseldorf, Germany - Vallourec Competence Center Riesa, Riesa, Germany France - Vallourec Research Center France, Aulnoye, France Brazil - Vallourec Research Center Brazil, Belo Horizonte, Brazil - Vallourec Competence Center Rio, Rio de Janeiro, Brazil USA - VAM Connection Technology Center USA, Houston, USA These centers, equipped with high-performance investigative and modelling tools, provide expertise to Vallourec’s core competencies, including metallurgy, heat transfer technology, non-destructive testing, corrosion, surface treatment, premium connection technology, and product and process simulations. Customized Solutions to Service Long Term Partnerships Vallourec offers a worldwide after-sale services network with VAM® Services and VAM® Field Service International: A VAM® licensee network with more than 200 workshops in over 40 countries located close to our customers operations worldwide. They provide accessories threading, repair and inspection of VAM® Premium Connections. VAM® Services, a division of Vallourec Oil & Gas France, is in charge of the quality management of the VAM® licensees’ network. This includes the qualification of new workshops, regular audits of each licensee, the dispatch and control of all VAM® technical documentation and tools such as gauges, inserts, etc. A full team of certified VAM® Field Services technicians are also available 24 hours a day to provide field support for inspection, rig preparation and supervision of running Vallourec pipe and VAM® connections throughout the world. High QHS&E Standards Vallourec has developed QHS&E standards to consistently comply with applicable regulations and national laws, while respecting and fulfilling country-specific needs. Quality High quality and service standards are maintained through the company’s Six Sigma and Continuous Improvement programs. All Vallourec facilities are ISO 9001: 2008 certified in addition to being licensed to manufacture API 5CT, 5L and 5D products. Vallourec deploys Continuous Improvement Process (CIP) Groups as part of its Total Quality Management program and constantly optimizes the performance of the workforce with dynamic, extended vocational training programs and efficient Competency Management systems. Health and Safety "The health and safety of our employees in all our locations is of key significance for the future of our company and it takes the very highest priority ..." (Chairman of the Executive Board of Vallourec). Hence, Vallourec is certified to OHSAS 18001:2007, demonstrating the company’s commitment to safety. Safety Mission Statement Ensure that Safety is a core business value. Implement and maintain a continuous improvement-based occupational safety and health (OSH) management system. Manage risks within acceptable industry standards to prevent occupational related injuries and illnesses. Promote a culture that does not accept injuries as a cost of doing business. Incorporate safety into every business process and decision. Measure performance and actively seek opportunities for improvement. Actively seek input and feedback from all Team Members. Comply with all regulatory standards and, where feasible, implement best practice methods. pg. 8 / Vallourec USA Corporation / Introduction Premium Products Environment Preserving our environment Lower CO2 emissions Through its environmental policy, Vallourec aims to minimize the environmental impact of its activities at all levels, and treats the well-being of future generations as a major priority. Vallourec environmental priorities focus on optimizing resources, reducing CO2 emissions and waste, as well as certifying facilities. Vallourec is committed to reducing CO2 emissions as exemplified by the steel manufacturing process at Vallourec do Brazil, which uses charcoal from its own eucalyptus plantations (Biomass) in its blast furnaces as a substitute for coke. As they grow, the trees in these plantations consume carbon dioxide and release oxygen. CO2 emissions from the steel mill are offset by absorptions by the eucalyptus plantations and as a result, the overall carbon balance for the production of steel in Brazil is the lowest in the market when compared with other methods of production (i.e. electric arc furnace or blast oxygen furnace). Optimization of resources A series of initiatives have been undertaken to optimize consumption of resources such as water, energy and raw materials, and to improve the conditions in which they are used. Considerable efforts have been made to reduce water consumption at all Vallourec locations, in particular by recycling water and collecting runoff. As a result, water use was cut in half in a ten year period. Capture and storage of CO2 One of the main areas of R&D focus for Vallourec concerns capture, transport and storage of CO2. The Vallourec Group is participating in the France Nord project alongside French and German research organizations. The objective of the project is to set up a pilot infrastructure in northern France for the transport and storage of CO2 in deep saline aquifers to be used for industrial emissions. The Vallourec Group together with several industrial partners and the French Environment and Energy Management Agency (ADEME) will finance this $75 million project. Waste reduction Vallourec is also working hard to cut pollutant emissions, reduce noise, decrease waste volumes and systematically recover and reprocess residual waste. All indicators measuring the release of pollutants into the environment comply with regulatory standards and performance has consistently improved over the last three years. Certified facilities Regular environmental audits are organized in each country to assess regulatory compliance, environmental performance and ecological risks. Most of Vallourec’s production facilities, representing 98% of total production, are certified ISO 14001. Vallourec USA Corporation / Premium Products / pg. 9 Premium Products Premium Products Premium Tubular Solutions Vallourec specializes in developing, manufacturing and servicing high performance, proprietary, custom and value added tubular solutions. With so many products to choose from, Vallourec provides engineering and technical services to assist you in selecting the optimal tubular solution for your particular downhole application. In addition to standard API 5CT casing grades, Vallourec produces pipe to meet specific customer requirements, including: Non-standard sizes and weights applications Custom grades Special inspections Special testing Special documentation Custom All Vallourec quenched and tempered (Q&T) API, API enhanced, and proprietary grades meet API 5CT (ISO 11960) PSL2 requirements. pg. 10 / Vallourec USA Corporation / Premium Products Enhanced Burst Casing Vallourec Star Enhanced Burst Casing (grade nomenclature denoted by E) delivers controlled yield strength with a higher burst rating than similar API grades. This feature not only enhances performance, but also allows a reduction of weight and cost compared to standard API casing grades. Additional benefits include: Modern metallurgical practices and process control produce yield strength limits optimized within the API range. Since the yield strength is within limits of API 5CT, enhanced burst can also be offered on our sour service grades as recommended by NACE Standard MR0175. Enhanced burst grades meet all minimum API 5CT PSL2 requirements and are API monogrammed. High Collapse Casing The Vallourec Group of Companies* High Collapse and Star Enhanced Collapse Casing (grade nomenclature denoted by HC & EC) delivers casing with a higher collapse rating than similar API grades. Compared to standard API grades, high collapse performance is verified by collapse testing samples that have a length to diameter ratio of 8:1. Hence, high collapse casing not only resists a higher range of external loads that will collapse conventional API casing, but also does a better job of preserving hole integrity during production. Vallourec USA Corporation/ Premium Products / pg. 11 Additional applications that often dictate the use of Vallourec high collapse casing include: Wells where additional safety margins are necessary due to the uncertainties of the formation and pressures to be encountered. Slim Well Designs where special drifts are common practice. Deep and High Pressure Wells which require optimization of all technical parameters in order to reach the pay zone with a “profitable” production size. Deep Water Risers measures profitability against each pound gained. Higher strength risers allow for smaller platforms and subsea equipment, which translates into lower overall production costs. Sour Service Environments where corrosion resistance adds one more constraint to the equation. High Reliability Standards (Health, Safety, Environment, HPHT) requiring a meaningful guarantee of performance. Exploration The Vallourec Group of Companies* high collapse casing often allows to reduce pipe weight and increase setting depth. Additional benefits include: P110EC provides the same internal yield strength (“burst”) rating as Q125 at a lower cost. Precise control of yield strength and wall thickness, combined with manufacturing practices results in minimal residual stress. High Collapse grades exceed all minimum API 5CT requirements and are API monogrammed. High Collapse with Enhanced Burst Casing Vallourec Star High Collapse with Enhanced Burst Casing (grade nomenclature denoted by HCE) offers the ultimate in tubular performance. These widely field proven casing products provide tubular technology that affords design options for the most difficult wells. Additional benefits include: HCE casing products have the burst resistance of Vallourec Star enhanced burst products with the increased collapse resistance of Vallourec Star high collapse products. High Collapse with enhanced Burst grades meet all API 5CT PSL2 requirements and are API monogrammed. VAM Riser The VAM Riser grades were developed for the high fatigue conditions experienced in top tension riser systems. Riser grades are available in 95ksi to 125ksi yield strengths. They were developed with a API 5CT PSL2 level as a basis with enhancements to improve riser fatigue usage. These inlclude: - chemistry - manufacturing route - hardness - impact toughness - CTOD performance - microstructure control - sulfide stress cracking resistance (for sour service grades) - dimensional control - and non-destructive inspection and testing Sour Service Casing “Sour Service” refers to a well environment containing Hydrogen Sulfide (H2S), which is naturally associated with acidic conditions. H2S comes from the decomposition of organic material, so it is often found in oil & gas environments which derive from the same phenomenon. Even if not sour at the onset, some wells become sour over time, as H2S bearing formation water starts to flow together with oil. It is well known that H2S is a hazard to human health, living organisms, and more generally to the environment. That is the reason why historically wells found in “Sour” environments were often plugged and abandoned. Today Sour Service environments provide further challenges with deeper wells, higher pressures and extreme corrosive conditions. Vallourec Sour Service Casing offers resistance to the most corrosive environments confirmed by extensive NACE testing. In addition, Vallourec provides workable solutions for the design of deep, high-pressure, sour wells by carefully designing and controlling the following parameters: Special chemistry and superior quench-and-temper processing ensure through wall uniformity and complete martensitic transformation. Superior sulfide stress cracking resistance is obtained by controlling hardness, strength, microstructure and utilizing practices that promote steel cleanliness and minimize residual stress. Standard sulfide stress corrosion resistance testing is conducted in conformance with NACE TM0177 requirements. NACE TM0177 Method D sulfide stress corrosion resistance testing can be provided. Vallourec Star also offers enhanced API sour service products such as T95E with higher burst and T95HC with higher collapse. For mild sour conditions Vallourec Star is offering P110MS which is tested in fit for purpose condition meeting the NACE MR0175 requirements. For severe sour service conditions or special applications such as HPHT, Vallourec offers proprietary grades with improved sour service performance. pg. 12 / Vallourec USA Corporation / Premium Products Vallourec USA Corporation / Premium Products / pg. 13 Vacuum Insulated Tubing (VIT) – THERMOCASE® Vallourec Tube-Alloy’s Vacuum Insulated Tubing, THERMOCASE®, a high-performance, double-walled tubular product, provides temperature isolation in response to various oilfield production challenges due to temperatures differences between the reservoir and wellhead. Vallourec Tube-Alloy Vacuum Insulated Tubing performance is stated as a ‘k’ value, which is expressed as BTUs/hourfoot-degree F. Currently, the product is capable of a joint-averaged k value of 0.004-0.006 in deepwater applications, and 0.006-0.02 in higher temperature applications such as steam flooding. Vallourec Tube-Alloy Vacuum Insulated Tubing advantages: Favored VIT deepwater supplier since 1999 Proven minimum 10 year service life Thermal modeling available for each project Worldwide installations in the most severe environments Robust construction beyond pipe limitations Multiple configurations to optimize solutions Manufactured in lengths up to and including Range 3 (RG3) Coupling insulations customized to the application Proven capability to qualify welding procedures for various pipe chemistries, e.g. carbon, super martensitic, stainless steels, nickel based alloys and super duplex THERMOCASE® is a registered trademark of Vallourec Tube-Alloy, LLC Thermocase® is ideal for the following applications: DEEPWATER CHALLENGES Annular Pressure Buildup (APB) - Arises from annular fluid heating with trapped annuli - Below Mudline, vacuum insulated tubing (THERMOCASE®) typically used to alleviate the root cause, the hot product inside cold annuli - Deep formation hydrate zones can be mobilized by operations, contributing to APB risk - Rupture disks, foamed cement mitigate consequences Wax and Hydrate Prevention (paraffin) - - Costly intervention (pigging, chemical injection, coiled tubing) avoided or reduced with insulation use Variety of technologies used in risers, flowlines (gels, syntactics, foams, rubbers, plastics, pipe-in- pipe, N2) Heavy Oil Flow Enhancement (viscosity) STEAM INJECTION Steam Injection - - Used in huff and puff, continuous injection and SAGD applications (API Grav < 14, no reservoir pressure) Use of insulated tubing can economically make-or-break exploitation of oil field VIT Model 750 Outer Tube Threaded Inner Tube Welded Inside of the Outer Tube Butt Weld Optional Forged Integral Upset Transition Spool Fillet Welds - Used in long strings to decrease viscosity, increase flow and enhance profitability (API Grav 14-17) Inner Pipe Outer Pipe PERMAFROST PRESERVATION Permafrost Preservation - - Subsidence prevention around ground-based wellhead, increasing access and stabilizing wellhead structures. Strict environmental regulations Thermocase® offers the highest level of thermal insulation available in a downhole tubular. pg. 14 / Vallourec USA Corporation / Premium Products Premium Services Expandable Tubulars (ET) Zonal Isolation Case Off Vallourec Expandable Tubulars (ET) minimize deep drilling issues, such as telescoping casing strings and borehole tapering, before reaching the pay zone. Minimal loss of inside casing diameter makes the technology applicable as a contingency casing string, drilling liner or cased-hole liner in both workover and completion operations. In addition, ET is ideal for deepwater projects and other specialized applications including: Incorporating Vallourec ET technology into Zonal Isolations solves lost circulation problems and seals off trouble zones where the pore pressure/fracture gradient relationship is a concern. Vallourec ET technology used in conjunction with case off applications will allow operators to seal-off perforations to shut off water production. Recompletion Recompletions utilizing Vallourec ET technology enables operators to run and expand a clad liner, typically after the fist year of production, in the horizontal section of the well and recomplete it to achieve greater production levels. Sidetrack Vallourec ET technology can be used in sidetrack applications allowing operators to enter new pay zones from a producing well while eliminating the cement job. Casing Remediation Incorporating Vallourec ET technology into Casing Remediation systems allows a bore size almost the same as the corroded casing interval that needs repair for production. Vallourec USA Corporation / Premium Services / pg. 15 Premium Services Premium Services Services for a Demanding Industry The Vallourec Group of companies offers a comprehensive range of innovative solutions in addition to premium OCTG products. These solutions are designed to meet the most challenging needs, from education and technical support to field and repair services. pg. 16 / Vallourec USA Corporation / Premium Services Vallourec USA Corporation / Premium Services / pg. 17 Education Well Design Technical Support Accessories Management Qualify your team with best in class education on tubular products from conception to completion. Vallourec’s Expert Instructors have high level content to choose from to offer tailor-made programs lasting anywhere from 2 to 5 days. Classes are offered in Optimize your well design and enhance your well integrity. Our Technical group can help your business with material selection, conventional / unconventional casing design and advanced casing design using our knowledge in A dedicated offer for your most demanding applications. Vallourec has dedicated R&D and test capacities for Vallourec Tube-Alloy offers a full range of tubing and casing accessories that delivers enhanced performance and production, including couplings, pup joints, and a variety of connectors. Many of these products are available from stock in a wide array of sizes and styles, while others are made to order. From the simplest J-55 API coupling to exotics such as an Inconel Premium Landing Nipple, Vallourec Tube-Alloy is the leading source for all accessory products. Pipe Manufacturing Well Design Integrity Corrosion Running and Handling Premium Connections Cost Optimization Safer Operations Well In addition, participants of our most popular class, Tubular Essentials, will be given the chance to tour our rolling mill located in Youngstown, Ohio as they learn about the pipe manufacturing process. and material manufacturing (CO2 & H2S) HP/HT & deepwater R&D support VAM premium connections Corrosion If brought in early in the design process we can help lower costs, increase safety factors, optimize annular clearance, and choose the best connections for the application. Materials Corrosion Testing Connections Connection Qualification FEA Simulations In addition, our group can help choose and supply grades / connections for any environment. Vallourec Tube-Alloy’s global stocking program provides products to all corners of the globe while assuring customers of timely, reliable delivery of quality products every time. Vallourec Tube-Alloy is able to provide products that meet or exceed customers’ expectations by continually producing new innovations that save time and money. A perfect example is the FloPup®, which combines a pup joint and flow coupling into one unit, reducing the number of threads, makeups and potential leak paths. Shale HP/HT Deepwater Corrosion High torque Riser Vallourec’s global network of VAM® technical experts and 24/7 access to www. vamservices.com and tech.support@ vam-usa.com for questions answered within one business day will help the job get done when it counts. Europe North America South America Africa Sales Offices Steel Plants Manufacturing Plants Asia and Middle East Accessories and Repair VAM® Licensee Facilities VAM® Field Service International pg. 18 / Vallourec USA Corporation / Premium Services Premium Connections Field Service VAM® Field Service technicians, comprising more than 225 field specialists located around the world, ensure VAM® Premium Connections are used safely in accordance with VAM® Field Procedures and avoid any deviation that could be detrimental to well life. VAM® Field Service adapts to your requirements and is available to maintain pipe integrity across the supply chain with: Rig-Ready/Rig-Return Pipe inspections Supply chain and pipe yard support VAM® Make-up supervision at the rig site Knowledge, training and tools required to perform field repair Full range of rental service equipment such as stabbing guides, lift plugs and crossover subs for safety valves and circulating heads VAM® Assembly make-up supervision and other specific services In addition to VAM® Premium Connection running experience, VAM® Field Service has accumulated over 25 years of valuable experience in many drilling and completion core competency areas including: Liner and hanger installations and CRA completions HP/HT wells Shale Gas and Tight Gas wells Risers Glass re-enforced epoxy lined tubulars Slim wells (GRE) Solid expandable tubulars Wireline strings requiring orientated couplings 13Cr Please remember that only VAM® service personnel have been properly trained to inspect, repair and run VAM® Premium Connections. Repair Services Ensure unique quality standards worldwide for VAM® thread manufacturing and make-up. Any shop in the VAM® network licensed to cut or repair threads goes through regular audits to maintain quality. At the customer’s request a Licensor Technical Representative (LTR) can be assigned to an order to keep watch of specific jobs. This translates into an assurance of quality and well integrity anytime VAM® threads are used on tubing, casing, and accessories. Vallourec USA Corporation / Premium Connections / pg. 19 Premium Connections Premium Connections World Leader for Premium Connections Vallourec, through its affiliates VAM USA, Vallourec Canada and Vallourec Mexico, offers the full range of VAM® products in North America. VAM®, the world leader for premium connection solutions for the oil and gas industry, benefits from a worldwide footprint of production facilities, three leading edge Research & Development Technology centers and a network of over 200 licensees worldwide. Vallourec, in combination with VAM USA, offers its customers integrated solutions and services fully adapted to the requirements of a fast moving energy market. VAM USA: an R&D Technology Center dedicated to North America The newly industrialized VAM USA R&D Technology Center, located in Houston, Texas, encompasses an extensive array of testing equipment used to simulate extreme well conditions. The North America R&D center validates the quality and reliability of VAM® connections under field-like conditions per standard ISO 13679 procedures and special customer procedures. In addition to qualification tests for customers, the lab actively participates in the development of new connections and the validation of new products. pg. 20 / Vallourec USA Corporation / Premium Connections Vallourec USA Corporation / Premium Connections / pg. 21 VAM USA Connection Technology Center: A comprehensive range of equipment The quest to find and recover new oil and gas reserves has never been more challenging. As these well conditions become more hostile, VAM® is ever more committed to designing connections suited for a variety of conditions including: Elevated Temperature Temperature fluctuations (Steam Injection or SAGD) High Pressure / High Temperature (HPHT) Sour Service Extreme Frac Pressures High Torque Fatigue Loading Severe Dog legs Extreme Your Challenge - Our Commitment VAM Premium Connections are used in the most hostile environments and applications. Operator safety, well life, return on investment (onshore and offshore) rely on the quality of our products. Therefore, the performance of all VAM connections are validated through full scale psychical testing at one of our three R&D centers to fully respond to those requirements. Threaded & Coupled Sample Preparation Bending A critical component for the development and validation of new products is sample preparation. VAM USA has incorporated the latest FEA equipment, CNC lathes and gauges within the testing facility to produce test specimens to the highest tolerances representing the worst case scenarios in the field. VAM USA has testing equipment that can simulate combined loads with bending (up to 70 degrees per 100ft). Make and Break VAM USA can perform make up and break out simulations that validate the seal sensitivity and galling sensitivity of VAM® premium connections under critical conditions. VAM USA also uses the tongs to evaluate the dope sensitivity of VAM® premium connections to new formulas of thread compound required by our customers including environmental friendly “green dope” or “CLEANWELL™”. Combined Loads (tension & compression with internal & external pressure) The VAM USA load f rames have a maximum tension capacity of 6 million pound force and a maximum compression capacity of 5.2 million pound force. VAM USA has the ability to simulate combined loads (tension or compression) under high internal pressure (30,000 psi using gas and 35,000 psi using water) or external pressure (35,000 psi). Elevated Temperature VAM USA can perform all simulations at ambient or elevated temperature (up to 600°F) including thermal cycles (ambient to elevated temperature). Fatigue Life VAM USA can perform fatigue tests that are required to assess the fatigue life of any VAM® premium connection (high stresses / low cycles or low stresses / high cycles). These extensive testing standards provide assurance to our North American customers that our premium connections have been physically tested beyond their stated capabilities and secure VAM® as the premier premium connection provider worldwide. The most important investment you can make to ensure the successful running of your premium tubulars is a VAM® Field Service representative. CONNECTION VAM 21 CONNECTION VAM TOP TYPE Threaded & Coupled TYPE Threaded & Coupled SIZE RANGE 5” to 14” SIZE RANGE 2 3/8” to 16” APPLICATIONS - Production casing - Intermediate casing - Rotating liner - Rotation during cementation - Wells with extreme compression loads APPLICATIONS - Production casing and tubing - Tie-backs - Intermediate casing - Rotating liner - Rotation during cementation - Wells with extreme compression loads BENEFITS - Excellent gas-tight sealing under combined loads - Reversed angle torque shoulder provides excellent resistance to bending, compression and torque - Seal protected from rough handling - Reduced drilling wear susceptibility - Extreme compression and torque resistance BENEFITS - Excellent gas-tight sealing under combined loads - Reversed angle torque shoulder provides excellent resistance to bending, compression and torque - Thread geometry optimized by size to minimize the risk of galling - Connection options allow for greater torque and compression RATINGS- ISO 13679 TESTED Internal Pressure 100% RATINGS Internal Pressure 100% External Pressure 100% External Pressure 100% Tension (% of Pipe Body) 100% Tension (% of Pipe Body) 100% Compression (% of Pipe Body) 100% Compression (% of Pipe Body) Tubing 100% Casing 60% - 100% (Tubing sizes currently being validated) OPTIONS HT – High Torque CLEANWELL® DRY SB – Special Bevel SC – Special Clearance OPTIONS HC – High Compression HT – High Torque SB – Special Bevel SC – Special Clearance CLEANWELL® DRY pg. 22 / Vallourec USA Corporation / Premium Connections Vallourec USA Corporation / Premium Connections / pg. 23 Threaded & Coupled CONNECTION VAM HP CONNECTION VAM HW-ST CONNECTION DWC/C CONNECTION BIG OMEGA TYPE Threaded & Coupled TYPE Threaded & Coupled TYPE Threaded & Coupled TYPE Threaded & Coupled SIZE RANGE 7” to 11” SIZE RANGE 5” to 14” SIZE RANGE 3 1/2" to 13 3/8” SIZE RANGE 14” to 26” APPLICATIONS - Heavy wall casing for HPHT - Production liners - Tie-backs - Casing hangers APPLICATIONS - Heavy wall casing for HPHT - Production liners - Tie-backs - Casing hangers APPLICATIONS - Drilling with casing - Production casing - Tubing APPLICATIONS - Surface casing BENEFITS - Dual gas-tight metal-to-metal seals - Reversed angle torque shoulder provides excellent resistance to bending, compression and torque RATINGS Internal Pressure 100% BENEFITS - Excellent gas-tight sealing under combined loads - Reversed angle torque shoulder provides excellent resistance to bending, compression and torque RATINGS Internal Pressure 100% External Pressure 100% External Pressure 70% External Pressure 100% Tension (% of Pipe Body) 100% Tension (% of Pipe Body) 80% - 100% Tension (% of Pipe Body) 100% Tension (% of Pipe Body) 100% Compression (% of Pipe Body) 70% Compression (% of Pipe Body) 60% Compression (% of Pipe Body) 40% Compression (% of Pipe Body) Up to 100% OPTIONS SB – Special Bevel SC – Special Clearance BENEFITS - Pin-to-pin torque shoulder - Excellent torque, compression and bending resistance - Improved thread sealing compared to buttress - Fatigue enhancements for drilling through a dogleg RATINGS Internal Pressure 100% OPTIONS HT – High Torque IS – Internal Shoulder SR – Seal Ring PLUS – Larger Coupling BENEFITS - Coarse rugged three-pitch thread form - Excellent stabbing and anti-cross threading - Improved thread sealing compared to buttress RATINGS Internal Pressure 100% External Pressure 100% pg. 24 / Vallourec USA Corporation / Premium Connections Vallourec USA Corporation / Premium Connections / pg. 25 Flush Semi-Flush CONNECTION VAM SG CONNECTION VAM SLIJ-II CONNECTION VAM HTF CONNECTION VAM BOLT TYPE Semi Flush TYPE Semi Flush TYPE Flush TYPE Flush SIZE RANGE 4 1/2" to 5 1/2” SIZE RANGE 4 1/2” to 16” SIZE RANGE 4 1/2” to 9 7/8” SIZE RANGE 11 7/8” to 18” APPLICATIONS - Production casing - Highly deviated wells - Long laterals BENEFITS - Specifically tested for Shale Well design applications - Gas-tight metal seal protected by mid-shoulder from handling damage - Deep stabbing two-step thread RATINGS Internal Pressure 100% APPLICATIONS - Production casing - Intermediate casing - Drilling liners - Drilling with casing - Tie-backs APPLICATIONS - Drilling liners - Drilling with casing - Production liners - Rotation during cementation BENEFITS - Dual gas-tight metal-to-metal seals - Maximum clearance – OD flush with the pipe - Dovetail thread form for extremely high torque capacity APPLICATIONS - Surface casing with tight clearance requirements - Ideal for running inside Big Bore wellhead systems External Pressure 70% Tension (% of Pipe Body) 90% Compression (% of Pipe Body) 63% BENEFITS - Optimized clearance with high tensile efficiency - Dual gas-tight metal-to-metal seals - Expanded box (2-3% over nominal pipe OD) - Deep stabbing two-step thread RATINGS Internal Pressure 100% External Pressure 100% Tension (% of Pipe Body) 68% - 82% Compression (% of Pipe Body) 47% - 57% RATINGS Internal Pressure 100% External Pressure 100% Tension (% of Pipe Body) 58% - 67% Compression (% of Pipe Body) 35% - 40% BENEFITS - Dual gas-tight metal-to-metal seals - Dovetail thread form for excellent jump-out resistance - Twin-lead thread for quick makeup - Flush OD - External torque shoulder RATINGS Internal Pressure 100% External Pressure 100% Tension (% of Pipe Body) 52% - 64% Compression (% of Pipe Body) 52% - 64% pg. 26 / Vallourec USA Corporation / Premium Connections Vallourec USA Corporation / Premium Connections / pg. 27 Special Applications Thermal Riser CONNECTION ST-L CONNECTION HD-L CONNECTION VAM SWI CONNECTION VAM TOP FE TYPE Flush TYPE Flush TYPE Threaded & Coupled TYPE Threaded & Coupled SIZE RANGE 2 3/8” to 14” SIZE RANGE 2 3/8” to 20” SIZE RANGE 4 1/2” to 13 3/8” SIZE RANGE 6 5/8” to 16” APPLICATIONS - Drilling liners - Moderate depth casing - Tight hole tubing strings - Tie-backs BENEFITS - Dual gas-tight metal-to-metal seals - Twin-lead thread for fast makeup - Maximum clearance – OD flush with the pipe RATINGS Internal Pressure 100% APPLICATIONS - Drilling liners - Moderate depth casing - Tight hole tubing strings - Tie-backs - Deviated wells with severe compression and bending APPLICATIONS - Thermal wells - SAGD (Steam Assisted Gravity Drainage) - Other steam applications APPLICATIONS - Drilling riser - Inner production riser External Pressure 100% BENEFITS - Dual gas-tight metal-to-metal seals - Single external metal seal above 14” - Maximum clearance – OD flush with the pipe - High compression rating RATINGS Internal Pressure 100% Tension (% of Pipe Body) 45% - 70% External Pressure 100% Compression (% of Pipe Body) 27% - 42% Tension (% of Pipe Body) 45% - 68% Compression (% of Pipe Body) 45% - 68% BENEFITS - Gas tight seal under most severe conditions - Excellent in heating and cooling cycles - High torque rating - Enhanced make up characteristics - Validated with full scale thermal testing to industry recognized test protocols RATINGS Internal Pressure 100% External Pressure 100% Tension (% of Pipe Body) 100% Compression (% of Pipe Body) 100% BENEFITS - VAM® TOP basis - Dovetail thread form for - Gas tight internal metal to metal seal - Rectangular thread profile - Fatigue enhancements - Swoosh - Radius on thread profile - SAF ≤ 2.0 vs. DNV-B1 2005 curve PERFORMANCES Static VAM® TOP basis 5 ~ 10 Make and Break Internal Pressure 100% External Pressure 100% API Tension (% of Pipe Body) 100% Compression (% of Pipe Body) 60% pg. 28/ Vallourec USA Corporation / Premium Connections Vallourec USA Corporation / Premium Connections / pg. 29 Riser Grade Riser Grade CONNECTION VAM TTR CONNECTION LDR TYPE Threaded & Coupled TYPE Threaded & Coupled SIZE RANGE 8 5/8” to 16” SIZE RANGE 7 5/8” APPLICATIONS - Outer production riser - Single barrier systems BENEFITS - External metal to metal seal - High fatigue triangular thread profile - SAF ≤ 1.5 vs. DNV-B1 2005 curve - Gas tight internal metal to metal seal PERFORMANCES Internal Pressure 100% APPLICATIONS - Workover / Landing string / Completion - HPHT External Pressure 100% API BENEFITS - External metal to metal seal - High fatigue triangular thread profile - SAF ≤ 1.5 vs. DNV-B1 2005 curve - Gas tight internal metal to metal seal - 25 Make and Breaks for work over applications PERFORMANCES 25 Make and Breaks for workover applications Tension (% of Pipe Body) 80% - 89% Internal Pressure 100% Compression (% of Pipe Body) 30 - 40% External Pressure 100% API OPTIONS HW - Heavy Wall Tension (% of Pipe Body) 90% Compression (% of Pipe Body) 40% pg. 30 / Vallourec USA Corporation / Premium Connections Material Properties Vallourec USA Corporation / Material Properties / pg. 31 Material Properties Material Properties Vallourec supplies the full range of API 5CT standard grades and grades with enhanced performances. All Product Specification Levels (PSL) and Special Requirements (SR) from API 5CT/ISO 11960 can be delivered, with PSL 2 standardized on all quenched and tempered grades. Grade J55 K55 VST55 HC N80 a L80 L80 HC L80 HCE L80 IRP L80 1Cr C90 C90 HC R95 T95 T95 HC T95 E T95 HCE C110 P110 MS b P110 P110 RY P110 EC P110 HCE Q125 Q125 HC Q125 HCE Yield Strength (ksi) Tensile Strength (ksi) minimum maximum minimum 55 55 70 80 80 80 87.5 80 80 90 90 95 95 95 100 100 110 110 110 110 125 125 125 125 135 80 80 110 110 95 95 95 95 95 105 105 110 110 110 110 110 120 125 140 125 140 140 150 150 150 75 95 110 100 95 95 95 95 95 100 100 105 105 105 105 105 115 125 125 125 135 135 135 135 140 HRC ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ 23.0 23.0 23.0 23.0 23.0 25.4 25.4 25.4 25.4 25.4 25.4 30.0 29.0 - a N80 Type 1 and N80Q (heat treated with additional criteria) are both available with the same strength requirements and load ratings. Contact Vallourec Sales for additional information. b Mild Sour Service material tested in a fit for purpose solution at 90% AYS using NACE method A. pg. 32 / Vallourec USA Corporation / Material Properties Vallourec USA Corporation / Material Properties / pg. 33 Material Properties Vallourec Proprietary Grades Vallourec proprietary grades offer solutions for grades or requirements not covered by API 5CT. They also offer greater performances (e.g. High Collapse grades) and higher reliability (e.g. Sour Service grades) thanks to stringent internal requirements in quality and process control, mechanical properties and material testing. Grade High Pressure High Temperature Grade VM125CY VM130CY VM140CY Yield Strength (ksi) VM140 VM150 maximum minimum 125 130 140 140 140 150 135 135 145 VM80HC VM95HC VM110HC VM125HC VM140HC VM150HC HRC Operating temp. for use in sour service conditions acc. to NACE ≤ 35 ≤ 35 ≤ 36 175°F 175°F 225°F Deep well grades are used where high yield strength is required while maintaining ductility and fracture toughness. Yield Strength (ksi) minimum maximum 140 150 165 175 High Collapse Grade Tensile Strength (ksi) minimum Deep Well Grade HPHT grades are used when high strength is required with limited resistance to sour service conditions within the guidelines of NACE MR0175. Tensile Strength (ksi) minimum CVN average value min. full size specimen at 70°F 150 38 ft-lbs 160 30 ft-lbs High Collapse grades for casing are used in high pressure wells. They offer an average of 25% and up to 40% extra performance over API collapse rating. As mechanical properties and pipe dimensions are major factors in collapse resistance, the following parameters have been optimized to guarantee high collapse pressure: D/t ratio, yield strength, ovality, wall thickness, residual stresses. Yield Strength (ksi) Tensile Strength (ksi) minimum maximum minimum 80 95 110 125 140 150 110 125 140 150 165 175 100 110 125 135 150 160 Collapse resistance minimum guaranteed collapse pressures are available upon request Sour Service grades for tubing and casing are used in wells where H2S is present. The threshold stresses have been determined according to Method A of NACE TM0177 standard. Upon request sour service grades are also tested according to Method D (DCB test). Sour Service VM80S VM80SS VM90S VM90SS VM95S VM95SS VM100SS VM110SS VM125SS Yield Strength (ksi) Tensile Strength (ksi) minimum maximum minimum 80 80 90 90 95 95 100 110 125 95 95 105 105 110 110 115 120 135 95 95 100 100 105 105 110 115 130 HRC Threshold stress minimum ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ 22 22 24 24 25 25 28 30 34 85% SMYS 90% SMYS 85% SMYS 90% SMYS 85% SMYS 90% SMYS 85% SMYS 85% SMYS 85% SMYS (0.03 ppH2S, pH 3.5) S Grades for faster delivery. High Collapse and Sour Service Grade VM80HCS VM80HCSS VM90HCS VM90HCSS VM95HCS VM95HCSS VM110HCSS VM125HCSS Yield Strength (ksi) High Collapse and Sour Service grades for casing are used in high pressure wells where H2S is present. Tensile Strength (ksi) minimum maximum minimum 80 80 90 90 95 95 110 125 95 95 105 105 110 110 120 135 95 95 100 100 105 105 115 130 HRC ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ 22 22 24 24 25 25 30 36 Threshold stress Collapse minimum resistance 85% 90% 85% 90% 85% 90% 85% 85% SMYS SMYS SMYS SMYS SMYS SMYS SMYS SMYS minimum guaranteed collapse pressures are available upon request pg. 34 / Vallourec USA Corporation / Material Properties Vallourec USA Corporation / Material Properties / pg. 35 Material Properties Sweet Corrosion Type 13% Chrome Super 13% Chrome Martensitic grades (13Cr and Super 13Cr) are used in wells with CO2, chlorides and/ or some H2S up to 365°F. Grade VM80 13CR VM85 13CR VM90 13CR VM95 13CR VM95 13CRSS VM110 13CRSS VM125 13CRSS Highly Corrosive Type Duplex Super Duplex Yield Strength (ksi) Tensile Strength (ksi) minimum maximum minimum 80 85 90 95 95 110 125 95 100 105 110 110 140 140 95 100 100 105 105 115 130 HRC ≤ ≤ ≤ ≤ ≤ ≤ ≤ 23 24 26 28 30 34 34 Grade Yield Strength (ksi) Tensile Strength (ksi) minimum maximum minimum 110 125 140 110 125 140 125 140 140 150 160 140 150 160 150 160 115 130 145 125 130 145 130 145 HRC ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ 36 37 38 36 37 38 37 38 Austenitic grades are used in wells where high concentration of H2S, CO2, and chlorides are present. Super Austenitic Nickel Base Alloys Risers Grade VM95R VM95RSS VM110R VM110RSS VM125R Riser grades from 95 ksi to 125 ksi minimum yield strength are used in high fatigue riser applications (available with Sour Service resistance). Yield Strength (ksi) Tensile Strength (ksi) minimum maximum minimum 95 95 110 110 125 110 110 125 120 140 105 105 120 115 135 HRC Threshold stress minimum ≤ ≤ ≤ ≤ ≤ 33 27 35 32 37 N/A 80% SMYS N/A 80% SMYS N/A Ferritic-austenitic grades to be used in wells with CO2, chlorides and/or some H2S up to 480°F. VM22 110 VM22 125 VM22 140 VM25 110 VM25 125 VM25 140 VM25S 125 VM25S 140 Type Special Applications Grade VM28 110 VM28 125 VM825 110 VM825 120 VM G3 110 VM G3 125 VM G50 110 VM G50 125 Yield Strength (ksi) Tensile Strength (ksi) minimum maximum minimum 110 125 110 120 110 125 110 125 140 150 135 145 130 145 130 145 115 130 115 125 115 130 115 130 HRC ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ 35 37 35 37 35 37 35 37 Expandables Grade VM50ET VM80ET VM80 13ET Expandable grades from 50 ksi to 80 ksi minimum yield strength are used in expandable tubular applications. Yield Strength ksi minimum maximum 50 80 80 65 95 95 Ultimate Tensile Strength ksi Elongation 2” % minimum minimum 69 95 95 25 20 18 HRC 25 20 18 pg. 36 / Vallourec USA Corporation / Material Properties Performance Data Tubing Vallourec USA Corporation / Performance Data / pg. 37 Performance Data Tubing Tubing Dimensions and Minimum Performance Properties OD Weight NU T&C (in) 5.80 6.60 7.35 6.40 4.70 5.95 - 7.45 6.50 Area PE (lb/ft) 4.60 2 3/8 EU T&C Wall (in) 4.44 5.76 6.56 7.32 6.17 (in2) 0.190 1.304 0.254 1.692 0.295 1.928 0.336 2.152 0.217 1.812 2 7/8 7.80 7.90 Abbreviated Terms NU non-upset tubing EU external upset tubing ALT. alternate drift IP internal pressure PBYS pipe body yield strength 7.67 0.276 2.254 Pipe Body Drift API ALT. (in) (in) Grade Collapse IP Pressure (Barlow) (psi) (psi) Connections IP (Lame’open) IP (Lame’capped) IP (Lame’ductile rupture) PBYS (psi) (psi) (psi) Non Upset (NU) Upset 8rd (EU) IP Jt. Strength IP Jt. Strength (kips) (psi) (kips) (psi) (kips) J55 8,100 7,700 7,600 8,250 7,880 72 7,700 49 7,700 72 K55 8,100 7,700 7,600 8,250 9,980 72 7,700 49 7,700 72 N80 11,780 11,200 11,060 12,000 10,630 104 11,200 72 11,200 104 L80 11,780 11,200 11,060 12,000 12,250 104 11,200 72 11,200 104 C90 13,250 12,600 12,440 13,500 12,960 117 12,600 81 12,600 117 R95 13,980 13,300 13,140 14,250 13,610 124 13,300 85 13,300 124 T95 13,980 13,300 13,140 14,250 13,640 124 13,300 85 13,300 124 P110 16,130 15,400 15,210 16,500 16,370 143 15,400 99 15,400 143 N80 15,280 14,970 14,640 15,640 14,470 135 14,970 103 14,850 135 L80 15,280 14,970 14,640 15,640 16,740 135 14,970 103 14,850 135 C90 17,190 16,840 16,470 17,590 17,710 152 16,840 116 16,710 152 R95 18,150 17,780 17,390 18,570 18,590 161 17,780 122 17,630 161 T95 18,150 17,780 17,390 18,570 18,640 161 17,780 122 17,630 161 P110 21,010 20,590 20,130 21,500 22,360 186 20,590 142 20,420 186 N80 17,410 17,390 16,870 17,860 17,010 154 - - - - L80 17,410 17,390 16,870 17,860 19,720 154 - - - - C90 19,580 19,560 18,980 20,090 20,860 173 - - - - R95 20,670 20,650 20,040 21,210 21,900 183 - - - - T95 20,670 20,650 20,040 21,210 21,960 183 - - - - P110 23,930 23,910 23,200 24,560 26,340 212 - - - - N80 19,430 19,810 19,050 20,000 19,600 172 - - 14,850 172 L80 19,430 19,810 19,050 20,000 22,790 172 - - 14,850 172 C90 21,860 22,280 21,430 22,500 24,100 194 - - 16,710 194 R95 23,080 23,520 22,620 23,750 25,310 204 - - 17,630 204 T95 23,080 23,520 22,620 23,750 25,370 204 - - 17,630 204 P110 26,720 27,230 26,190 27,500 30,430 237 - - 20,420 237 J55 7,680 7,260 7,180 7,820 7,410 100 7,260 73 7,260 100 K55 7,680 7,260 7,180 7,820 9,390 100 7,260 73 7,260 100 N80 11,170 10,570 10,450 11,370 10,000 145 10,570 106 10,570 145 2.347 N/A L80 C90 11,170 10,570 10,450 11,370 11,520 145 10,570 106 10,570 145 12,380 11,890 11,760 12,790 12,190 163 11,890 119 11,890 163 R95 12,940 12,550 12,410 13,500 12,790 172 12,550 125 12,550 172 T95 12,940 12,550 12,410 13,500 12,830 172 12,550 125 12,550 172 P110 14,550 14,530 14,370 15,630 15,380 199 14,530 145 14,530 199 N80 13,890 13,440 13,200 14,190 12,900 180 13,440 141 13,440 180 L80 13,890 13,440 13,200 14,190 14,890 180 13,440 141 13,440 180 1.901 N/A 1.773 N/A 1.691 N/A 1.609 N/A 2.229 N/A pg. 38 / Vallourec USA Corporation / Performance Data Vallourec USA Corporation / Performance Data / pg. 39 Tubing Dimensions and Minimum Performance Properties OD Weight NU T&C (in) EU T&C Wall PE (lb/ft) 7.80 7.90 Area (in) 7.67 (in2) 0.276 2.254 Pipe Body Drift API ALT. (in) (in) 9.20 8.70 9.30 8.45 8.81 0.308 2.484 0.254 2.590 - 9.92 0.289 2.915 12.70 12.95 12.53 0.375 3.682 4 9.50 - Abbreviated Terms NU non-upset tubing EU external upset tubing ALT. alternate drift IP internal pressure PBYS pipe body yield strength 9.12 0.226 2.680 Collapse IP Pressure (Barlow) (psi) (psi) IP (Lame’open) IP (Lame’capped) IP (Lame’ductile rupture) PBYS (psi) (psi) (psi) Non Upset (NU) OD Jt. Strength IP Jt. Strength (kips) (psi) (kips) (psi) (kips) 203 15,120 158 15,120 203 2.229 N/A R95 T95 16,490 15,960 15,680 16,840 16,540 214 15,960 167 15,960 214 16,490 15,960 15,680 16,840 16,580 214 15,960 167 15,960 P110 19,090 18,480 18,150 19,500 19,890 248 18,480 194 N80 15,300 15,000 14,670 15,660 14,500 199 15,000 159 L80 15,300 15,000 14,670 15,660 16,770 199 15,000 C90 17,220 16,870 16,500 17,620 17,740 224 16,870 2.165 N/A 2.867 N/A 2.797 N/A 2.625 N/A 3.423 N/A Weight Wall Area Pipe Body Drift Upset 8rd (EU) IP 15,620 15,120 14,850 15,960 15,760 3 1/2 10.20 Grade Connections C90 2 7/8 8.60 Tubing Dimensions and Minimum Performance Properties NU T&C (in) EU T&C PE (lb/ft) (in) (in2) API ALT. (in) (in) Grade Collapse IP Pressure (Barlow) (psi) (psi) Connections IP (Lame’open) IP (Lame’capped) IP (Lame’ductile rupture) PBYS (psi) (psi) (psi) Non Upset (NU) Upset 8rd (EU) IP Jt. Strength IP Jt. Strength (kips) (psi) (kips) (psi) (kips) T95 7,310 9,390 9,340 10,290 9,460 255 9,390 171 - - P110 7,910 10,880 10,810 11,910 11,350 295 10,880 198 - - 214 J55 6,590 6,300 6,250 6,850 6,390 169 - - 6,300 169 18,480 248 N80 8,800 9,170 9,090 9,960 8,620 246 - - 9,170 246 14,940 199 L80 8,800 9,170 9,090 9,960 9,920 246 - - 9,170 246 159 14,940 199 3.351 N/A C90 9,590 10,320 10,230 11,200 10,490 277 - - 10,320 277 179 16,810 224 R95 9,980 10,890 10,800 11,830 11,020 292 - - 10,890 292 9.50 - 9.12 0.226 2.680 10.70 11.00 10.47 0.262 3.077 3.423 N/A 4 R95 18,170 17,810 17,420 18,600 18,630 236 17,810 189 17,750 236 T95 9,980 10,890 10,800 11,830 11,040 292 - - 10,890 292 T95 18,170 17,810 17,420 18,600 18,680 236 17,810 189 17,750 236 P110 11,060 12,610 12,500 13,690 13,250 338 - - 12,610 338 P110 21,040 20,620 20,170 21,540 22,400 273 20,620 219 20,550 273 N80 12,110 11,550 11,400 12,350 10,990 304 - - - - J55 7,400 6,990 6,910 7,540 7,110 142 6,990 109 6,990 142 L80 12,110 11,550 11,400 12,350 12,660 304 - - - - K55 7,400 6,990 6,910 7,540 9,010 142 6,990 109 6,990 142 C90 13,620 12,990 12,820 13,890 13,390 342 - - - - N80 10,540 10,160 10,060 10,960 9,600 207 10,160 159 10,160 207 R95 14,380 13,720 13,530 14,660 14,060 361 - - - - L80 10,540 10,160 10,060 10,960 11,050 207 10,160 159 10,160 207 T95 14,380 13,720 13,530 14,660 14,100 361 - - - - C90 11,570 11,430 11,310 12,330 11,690 233 11,430 179 11,430 233 P110 16,650 15,880 15,670 16,980 16,910 419 - - - - R95 12,080 12,070 11,940 13,020 12,270 246 12,070 189 12,070 246 J55 5,730 5,800 5,760 6,330 5,850 198 5,800 144 5,800 198 T95 12,080 12,070 11,940 13,020 12,300 246 12,070 189 12,070 246 K55 5,730 5,800 5,760 6,330 7,410 198 5,800 144 5,800 198 P110 13,530 13,970 13,830 15,070 14,760 285 13,970 219 13,970 285 N80 7,500 8,430 8,370 9,200 7,900 288 8,430 209 8,430 288 N80 12,120 11,560 11,410 12,360 11,000 233 11,560 185 - - L80 7,500 8,430 8,370 9,200 9,080 288 8,430 209 8,430 288 L80 12,120 11,560 11,410 12,360 12,670 233 11,560 185 - - C90 8,120 9,490 9,420 10,350 9,610 324 9,490 235 9,490 324 C90 13,640 13,010 12,830 13,900 13,410 262 13,010 208 - - R95 8,410 10,010 9,940 10,930 10,090 342 10,010 248 10,010 342 R95 14,390 13,730 13,550 14,670 14,080 277 13,730 220 - - T95 8,410 10,010 9,940 10,930 10,110 342 10,010 248 10,010 342 T95 14,390 13,730 13,550 14,670 14,110 277 13,730 220 - - P110 9,210 11,590 11,510 12,650 12,130 396 11,590 287 11,590 396 P110 16,670 15,900 15,690 16,990 16,930 321 15,900 255 - - N80 11,080 10,480 10,370 11,290 9,920 353 - - - - N80 15,310 15,000 14,670 15,660 14,500 295 15,000 246 15,000 295 L80 11,080 10,480 10,370 11,290 11,420 353 - - - - L80 15,310 15,000 14,670 15,660 16,770 295 15,000 246 15,000 295 C90 12,220 11,800 11,670 12,700 12,080 397 - - - - C90 17,220 16,880 16,500 17,620 17,740 331 16,880 277 16,880 331 R95 12,760 12,450 12,310 13,400 12,690 419 - - - - R95 18,180 17,810 17,420 18,600 18,630 350 17,810 293 17,810 350 T95 12,760 12,450 12,310 13,400 12,720 419 - - - - T95 18,180 17,810 17,420 18,600 18,680 350 17,810 293 17,810 350 P110 14,340 14,420 14,260 15,520 15,260 485 - - - - P110 21,050 20,630 20,170 21,540 22,400 405 20,630 339 20,630 405 J55 5,110 5,440 5,400 5,960 5,480 147 5,440 99 - - K55 5,110 5,440 5,400 5,960 6,940 147 5,440 99 - - N80 6,590 7,910 7,860 8,660 7,400 214 7,910 144 - - L80 6,590 7,910 7,860 8,660 8,490 214 7,910 144 - - C90 7,080 8,900 8,840 9,740 8,990 241 8,900 162 - - R95 7,310 9,390 9,340 10,290 9,440 255 9,390 171 - - 13.20 - 12.95 0.330 3.805 12.60 12.75 12.25 0.271 3.600 3.215 N/A 3.833 N/A 4 1/2 15.20 - Abbreviated Terms NU non-upset tubing EU external upset tubing ALT. alternate drift IP internal pressure PBYS pipe body yield strength 15.00 0.337 4.407 3.701 N/A Vallourec USA Corporation / Performance Data / pg. 40 Tubing Dimensions and Minimum Performance Properties Performance Data 4 1/2” - 7” Vallourec USA Corporation / Performance Data 4 1/2” -7” / pg. 41 Performance Data 4 1/2" - 7" Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) 4 1/2 Wall Area PE (lb/ft) 9.50 9.41 (in) (in2) Pipe Body Drift API ALT. (in) (in) 0.205 2.766 3.965 N/A 4 1/2 10.50 10.24 0.224 3.009 3.927 N/A 4 1/2 11.60 10.24 0.224 3.009 3.927 N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) J55 3,310 4,380 4,370 4,850 4,400 152 4,380 101 - - - - K55 3,310 4,380 4,370 4,850 5,570 152 4,380 112 - - - - J55 4,010 4,790 4,770 5,280 4,820 166 4,790 132 - - K55 4,010 4,790 4,770 5,280 6,100 166 4,790 146 - - J55 4,960 5,350 5,320 5,860 5,400 184 5,350 154 5,350 162 5,350 225 K55 4,960 5,350 5,320 5,860 6,840 184 5,350 170 5,350 180 5,350 277 N80 6,360 7,780 7,730 8,520 7,290 267 7,780 216 7,780 223 7,780 304 L80 4,790 203 4,790 249 6,360 7,780 7,730 8,520 8,370 267 7,780 212 7,780 212 7,780 291 L80 1Cr 6,360 7,780 7,730 8,520 8,370 267 7,780 212 7,780 212 7,780 291 L80 HC 7,720 7,780 7,730 8,520 8,370 267 7,780 212 7,780 212 7,780 291 L80 IRP 6,360 7,780 7,730 8,520 8,370 267 7,780 212 7,780 212 7,780 291 L80 HCE 7,720 8,510 8,460 9,320 8,370 292 8,510 212 8,510 212 8,510 295 C90 6,810 8,750 8,700 9,590 9,730 300 8,750 223 8,750 223 8,750 309 R95 7,030 9,240 9,180 10,120 9,310 317 9,240 234 9,240 234 9,240 325 T95 7,030 9,240 9,180 10,120 10,280 317 9,240 234 9,240 234 9,240 325 T95 HC 8,550 9,240 9,180 10,120 10,280 317 9,240 234 9,240 234 9,240 325 T95 E 7,030 9,720 9,660 10,660 10,280 334 9,720 234 9,720 234 9,720 328 T95 HCE 8,550 9,720 9,660 10,660 10,280 334 9,720 234 9,720 234 9,720 328 P110 7,580 10,690 10,630 11,720 11,150 367 10,690 279 10,690 279 10,690 385 P110 RY 7,580 10,690 10,630 11,720 11,150 367 10,690 279 10,690 279 10,690 385 P110 MS 7,580 10,690 10,630 11,720 11,150 367 10,690 279 10,690 279 10,690 385 P110 EC 8,860 12,150 12,080 13,320 13,380 417 12,150 301 12,150 301 12,150 420 P110 HCE 9,590 12,150 12,080 13,320 13,380 417 12,150 301 12,150 301 12,150 420 Q125 8,000 12,150 12,080 13,320 13,380 417 12,150 301 12,150 301 12,150 420 Q125 HC 9,870 12,150 12,080 13,320 13,380 417 12,150 301 12,150 301 12,150 420 Q125 HCE 9,870 13,130 13,050 14,390 13,960 451 13,130 312 13,130 312 13,130 438 4 1/2 12.75 12.25 0.271 3.600 3.833 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A N80 7,500 8,430 8,370 9,200 7,690 288 - - - - - - L80 7,500 8,430 8,370 9,200 7,690 288 - - - - - - L80 IRP 7,500 8,430 8,370 9,200 7,690 288 - - - - - - C90 8,120 9,490 9,420 10,350 10,540 324 - - - - - - R95 8,410 10,010 9,940 10,930 10,000 342 - - - - - - T95 8,410 10,010 9,940 10,930 11,140 342 - - - - - - T95 E 8,410 10,540 10,460 11,500 11,140 360 - - - - - - P110 9,210 11,590 11,510 12,650 13,340 396 - - - - - - P110 RY 9,210 11,590 11,510 12,650 13,340 396 - - - - - - P110 MS 9,210 11,590 11,510 12,650 13,340 396 - - - - - - pg. 42 / Vallourec USA Corporation / Performance Data 4 1/2” -7” Vallourec USA Corporation / Performance Data 4 1/2” -7” / pg. 43 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 4 1/2 12.75 12.25 0.271 3.600 3.833 N/A Grade 4 1/2 13.50 13.05 0.290 3.836 3.795 4 1/2 15.10 15.00 0.337 4.407 3.701 N/A N/A Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) P110 EC 9,890 13,170 13,080 14,380 14,410 450 - - - - - - Q125 9,890 13,170 13,080 14,380 14,410 450 - - - - - - 8,540 9,020 8,950 9,810 8,500 - - (psi) N80 (psi) (psi) (psi) (psi) (kips) 307 Weight Wall Area Pipe Body Drift BC IP 9,020 270 T&C (in) PE (lb/ft) (in) (in2) API ALT. (in) (in) 9,020 349 4 1/2 15.10 15.00 0.337 4.407 3.701 N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) P110 RY 14,340 14,420 14,260 15,520 16,880 485 - - 14,420 406 13,470 509 P110 MS 14,340 14,420 14,260 15,520 16,880 485 - - 14,420 406 13,470 509 P110 EC 15,830 16,380 16,200 17,640 18,350 551 - - 16,380 438 15,300 554 (psi) (psi) (psi) (psi) (psi) (kips) 8,540 9,020 8,950 9,810 9,780 307 - - 9,020 257 9,020 334 P110 HCE 16,090 16,380 16,200 17,640 18,350 551 - - 16,380 438 15,300 554 L80 1Cr 8,540 9,020 8,950 9,810 9,780 307 - - 9,020 257 9,020 334 C110 14,340 14,420 14,260 15,520 15,530 485 - - 14,420 373 13,470 475 L80 HC 9,560 9,020 8,950 9,810 9,780 307 - - 9,020 257 9,020 334 Q125 15,830 16,380 16,200 17,640 18,350 551 - - 16,380 438 15,300 554 L80 IRP 8,540 9,020 8,950 9,810 9,780 307 - - 9,020 257 9,020 334 Q125 HC 17,330 16,380 16,200 17,640 18,350 551 - - 16,380 438 15,300 554 L80 HCE 9,560 9,870 9,790 10,730 9,780 9,870 339 17,690 454 16,530 578 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties L80 336 - - 9,870 257 Q125 HCE 17,330 17,690 17,500 19,050 19,140 595 - - C90 9,300 10,150 10,070 11,030 11,380 345 - - 10,150 270 10,150 355 N80 12,220 11,670 11,510 12,460 11,130 389 - - - - - - R95 9,660 10,710 10,630 11,650 10,870 364 - - 10,710 284 10,710 374 L80 12,220 11,670 11,510 12,460 12,830 389 - - - - - - T95 9,660 10,710 10,630 11,650 12,020 364 - - 10,710 284 10,710 374 L80 1Cr 12,220 11,670 11,510 12,460 12,830 389 - - - - - - T95 HC 10,850 10,710 10,630 11,650 12,020 364 - - 10,710 284 10,710 374 L80 HC 13,370 11,670 11,510 12,460 12,830 389 - - - - - - T95 E 9,660 11,280 11,190 12,260 12,020 384 - - 11,280 284 11,280 377 L80 IRP 12,220 11,670 11,510 12,460 12,830 389 - - - - - - T95 HCE 10,850 11,280 11,190 12,260 12,020 384 - - 11,280 284 11,280 377 L80 HCE 13,370 12,760 12,590 13,630 12,830 425 - - - - - - P110 10,690 12,410 12,310 13,490 14,400 422 - - 12,410 338 12,410 443 C90 13,750 13,130 12,950 14,020 14,960 437 - - - - - - P110 RY 10,690 12,410 12,310 13,490 14,400 422 - - 12,410 338 12,410 443 R95 14,510 13,850 13,670 14,800 14,270 462 - - - - - - P110 MS 10,690 12,410 12,310 13,490 14,400 422 - - 12,410 338 12,410 443 T95 14,510 13,850 13,670 14,800 15,800 462 - - - - - - P110 EC 11,600 14,100 13,980 15,320 15,640 479 - - 14,100 365 14,100 482 T95 HC 15,280 13,850 13,670 14,800 15,800 462 - - - - - - T95 E 14,510 14,580 14,390 15,580 15,800 486 - - - - - - 4 1/2 16.60 16.54 0.375 4.860 3.625 N/A P110 HCE 12,840 14,100 13,980 15,320 15,640 479 - - 14,100 365 14,100 482 C110 10,690 12,410 12,310 13,490 13,250 422 - - 12,410 311 12,410 413 T95 HCE 15,280 14,580 14,390 15,580 15,800 486 - - - - - - Q125 11,600 14,100 13,980 15,320 15,640 479 - - 14,100 365 14,100 482 P110 16,810 16,040 15,830 17,130 18,930 535 - - - - - - Q125 HC 13,810 14,100 13,980 15,320 15,640 479 - - 14,100 365 14,100 482 P110 RY 16,810 16,040 15,830 17,130 18,930 535 - - - - - - Q125 HCE 13,810 15,230 15,100 16,550 16,320 518 - - 15,230 378 15,230 503 P110 MS 16,810 16,040 15,830 17,130 18,930 535 - - - - - - N80 11,080 10,480 10,370 11,290 9,950 353 - - 10,480 325 9,790 401 P110 EC 17,710 18,230 17,980 19,470 20,570 607 - - - - - - L80 11,080 10,480 10,370 11,290 11,450 353 - - 10,480 308 9,790 384 P110 HCE 19,100 18,230 17,980 19,470 20,570 607 - - - - - - L80 1Cr 11,080 10,480 10,370 11,290 11,450 353 - - 10,480 308 9,790 384 C110 16,810 16,040 15,830 17,130 17,410 535 - - - - - - L80 HC 11,950 10,480 10,370 11,290 11,450 353 - - 10,480 308 9,790 384 Q125 19,100 18,230 17,980 19,470 20,570 607 - - - - - - L80 IRP 11,080 10,480 10,370 11,290 11,450 353 - - 10,480 308 9,790 384 Q125 HC 20,510 18,230 17,980 19,470 20,570 607 - - - - - - L80 HCE 11,950 11,470 11,340 12,350 11,450 386 - - 11,470 308 10,710 389 Q125 HCE 20,510 19,690 19,420 21,030 21,460 656 - - - - - - C90 12,220 11,800 11,670 12,700 13,340 397 - - 11,800 325 11,020 408 N80 13,830 13,380 13,140 14,130 12,870 440 - - - - - - R95 12,760 12,450 12,310 13,400 12,740 419 - - 12,450 341 11,630 429 L80 13,830 13,380 13,140 14,130 14,860 440 - - - - - - T95 L80 1Cr 13,830 13,380 13,140 14,130 14,860 440 - - - - - - L80 HC 15,170 13,380 13,140 14,130 14,860 440 - - - - - - 12,760 12,450 12,310 13,400 14,100 419 - - 12,450 341 11,630 429 T95 HC 13,300 12,450 12,310 13,400 14,100 419 - - 12,450 341 11,630 429 T95 E 12,760 13,110 12,960 14,110 14,100 441 - - 13,110 341 12,240 433 L80 IRP 13,830 13,380 13,140 14,130 14,860 440 - - - - - - T95 HCE 13,300 13,110 12,960 14,110 14,100 441 - - 13,110 341 12,240 433 L80 HCE 15,170 14,630 14,370 15,450 14,860 481 - - - - - - P110 - - 14,420 406 13,470 509 - - - - - - 14,340 14,420 14,260 15,520 16,880 485 4 1/2 21.50 21.38 0.500 6.283 3.375 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A C90 15,560 15,050 14,780 15,890 17,340 495 pg. 44 / Vallourec USA Corporation / Performance Data 4 1/2” -7” Vallourec USA Corporation / Performance Data 4 1/2” -7” / pg. 45 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 4 1/2 18.90 18.71 0.430 5.498 3.515 4 1/2 21.50 21.38 0.500 6.283 3.375 5 15.00 14.88 0.296 4.374 4.283 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties N/A N/A N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC 8rd LC OD BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) R95 16,420 15,890 15,610 16,770 16,520 522 - - - - - - K55 5,560 5,700 5,660 6,220 7,300 241 5,700 228 5,700 246 5,700 359 T95 16,420 15,890 15,610 16,770 18,320 522 - - - - - - N80 7,250 8,290 8,230 9,050 7,780 350 8,290 291 8,290 311 8,290 396 T95 HC 17,560 15,890 15,610 16,770 18,320 522 - - - - - - L80 7,250 8,290 8,230 9,050 8,940 350 8,290 286 8,290 295 8,290 379 T95 E 16,420 16,720 16,430 17,660 18,320 550 - - - - - - L80 1Cr 7,250 8,290 8,230 9,050 8,940 350 8,290 286 8,290 295 8,290 379 T95 HCE 17,560 16,720 16,430 17,660 18,320 550 - - - - - - L80 HC 8,510 8,290 8,230 9,050 8,940 350 8,290 286 8,290 295 8,290 379 P110 19,010 18,390 18,070 19,420 21,940 605 - - - - - - L80 IRP 7,250 8,290 8,230 9,050 8,940 350 8,290 286 8,290 295 8,290 379 P110 RY 19,010 18,390 18,070 19,420 21,940 605 - - - - - - L80 HCE 8,510 9,070 9,000 9,900 8,940 383 9,070 295 9,070 295 9,070 385 P110 MS 19,010 18,390 18,070 19,420 21,940 605 - - - - - - C90 7,830 9,320 9,260 10,190 10,400 394 9,320 311 9,320 311 9,320 404 P110 EC 21,610 20,900 20,530 22,070 23,840 687 - - - - - - R95 8,110 9,840 9,780 10,750 9,950 416 9,840 326 9,840 326 9,840 424 P110 HCE 21,730 20,900 20,530 22,070 23,840 687 - - - - - - T95 8,110 9,840 9,780 10,750 10,990 416 9,840 326 9,840 326 9,840 424 C110 19,010 18,390 18,070 19,420 20,190 605 - - - - - - T95 HC 9,540 9,840 9,780 10,750 10,990 416 9,840 326 9,840 326 9,840 424 Q125 8,110 10,360 10,290 11,320 10,990 437 10,360 326 10,360 326 10,360 429 5 15.00 14.88 0.296 4.374 4.283 N/A 21,610 20,900 20,530 22,070 23,840 687 - - - - - - T95 E Q125 HC 23,370 20,900 20,530 22,070 23,840 687 - - - - - - T95 HCE 9,540 10,360 10,290 11,320 10,990 437 10,360 326 10,360 326 10,360 429 Q125 HCE 23,370 22,580 22,180 23,840 24,880 742 - - - - - - P110 N80 15,800 15,560 15,180 16,180 15,120 503 - - - - - - P110 RY 8,850 11,400 11,320 12,450 13,170 481 11,400 387 11,400 388 11,400 503 L80 8,850 11,400 11,320 12,450 13,170 481 11,400 387 11,400 388 11,400 503 15,800 15,560 15,180 16,180 17,500 503 - - - - - - P110 MS 8,850 11,400 11,320 12,450 13,170 481 11,400 387 11,400 388 11,400 503 L80 1Cr 15,800 15,560 15,180 16,180 17,500 503 - - - - - - P110 EC 9,480 12,950 12,860 14,150 14,310 547 12,950 420 12,950 420 12,950 548 L80 HC 17,900 15,560 15,180 16,180 17,500 503 - - - - - - P110 HCE 10,970 12,950 12,860 14,150 14,310 547 12,950 420 12,950 420 12,950 548 L80 IRP 15,800 15,560 15,180 16,180 17,500 503 - - - - - - Q125 L80 HCE 17,900 17,010 16,610 17,700 17,500 550 - - - - - - Q125 HC 11,400 12,950 12,860 14,150 14,310 547 12,950 420 12,950 420 12,950 548 C90 17,780 17,500 17,080 18,210 20,450 565 - - - - - - Q125 HCE 11,400 13,990 13,890 15,280 14,930 591 13,990 435 13,990 435 13,990 573 R95 18,770 18,470 18,030 19,220 19,460 597 - - - - - - N80 10,500 10,140 10,030 10,940 9,600 422 - - 10,140 396 9,910 477 T95 18,770 18,470 18,030 19,220 21,600 597 - - - - - - L80 10,500 10,140 10,030 10,940 11,050 422 - - 10,140 376 9,910 457 T95 HC 20,750 18,470 18,030 19,220 21,600 597 - - - - - - L80 1Cr 10,500 10,140 10,030 10,940 11,050 422 - - 10,140 376 9,910 457 T95 E 18,770 19,440 18,980 20,230 21,600 628 - - - - - - L80 HC 11,400 10,140 10,030 10,940 11,050 422 - - 10,140 376 9,910 457 T95 HCE 20,750 19,440 18,980 20,230 21,600 628 - - - - - - L80 IRP 10,500 10,140 10,030 10,940 11,050 422 - - 10,140 376 9,910 457 P110 21,730 21,390 20,880 22,250 25,870 691 - - - - - - L80 HCE 11,400 11,090 10,970 11,960 11,050 462 - - 11,090 376 10,840 465 P110 RY 21,730 21,390 20,880 22,250 25,870 691 - - - - - - C90 11,520 11,400 11,290 12,310 12,870 475 - - 11,400 396 11,150 487 P110 MS 21,730 21,390 20,880 22,250 25,870 691 - - - - - - R95 12,020 12,040 11,910 12,990 12,290 501 - - 12,040 416 11,770 512 P110 EC 24,690 24,310 23,730 25,280 28,120 785 - - - - - - T95 12,020 12,040 11,910 12,990 13,600 501 - - 12,040 416 11,770 512 P110 HCE 25,700 24,310 23,730 25,280 28,120 785 - - - - - - T95 HC 12,670 12,040 11,910 12,990 13,600 501 - - 12,040 416 11,770 512 C110 21,730 21,390 20,880 22,250 23,800 691 - - - - - - T95 E 12,020 12,670 12,540 13,670 13,600 527 - - 12,670 416 12,390 517 Q125 24,690 24,310 23,730 25,280 28,120 785 - - - - - - T95 HCE 12,670 12,670 12,540 13,670 13,600 527 - - 12,670 416 12,390 517 Q125 HC 27,780 24,310 23,730 25,280 28,120 785 - - - - - - P110 13,470 13,940 13,800 15,040 16,290 580 - - 13,940 495 13,630 606 Q125 HCE 27,780 26,250 25,620 27,310 29,340 848 - - - - - - P110 RY 13,470 13,940 13,800 15,040 16,290 580 - - 13,940 495 13,630 606 P110 MS 13,470 13,940 13,800 15,040 16,290 580 - - 13,940 495 13,630 606 J55 5,560 5,700 5,660 6,220 5,770 241 5,700 207 5,700 223 5 18.00 17.95 0.362 5.275 4.151 5,700 293 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A 9,480 12,950 12,860 14,150 14,310 547 12,950 420 12,950 420 12,950 548 pg. 46 / Vallourec USA Corporation / Performance Data 4 1/2” -7” Vallourec USA Corporation / Performance Data 4 1/2” -7” / pg. 47 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) 5 5 5 Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 18.00 17.95 0.362 5.275 4.151 21.40 21.32 0.437 6.264 4.001 23.20 23.11 0.478 6.791 3.919 N/A N/A N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) P110 EC 14,820 15,840 15,680 17,090 17,700 659 - - 15,840 535 15,490 661 P110 HCE 15,360 15,840 15,680 17,090 17,700 659 - - C110 13,470 13,940 13,800 15,040 14,980 580 - Q125 (psi) (psi) (psi) (psi) (psi) (kips) Weight Wall Area Pipe Body Drift BC IP T&C PE API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) T95 HC 17,570 15,890 15,610 16,780 18,330 645 - - 12,840 567 11,770 564 15,840 535 15,490 661 T95 E 16,430 16,730 16,430 17,660 18,330 679 - - 13,520 567 12,390 564 - 13,940 456 13,630 566 T95 HCE 17,570 16,730 16,430 17,660 18,330 679 - - 13,520 567 12,390 564 (in) (lb/ft) (in) (in2) (psi) (psi) (psi) (psi) (psi) (kips) 14,820 15,840 15,680 17,090 17,700 659 - - 15,840 535 15,490 661 P110 19,020 18,400 18,080 19,430 21,950 747 - - 14,870 675 13,630 671 Q125 HC 15,670 15,840 15,680 17,090 17,700 659 - - 15,840 535 15,490 661 P110 RY 19,020 18,400 18,080 19,430 21,950 747 - - 14,870 675 13,630 671 Q125 HCE 15,670 17,100 16,930 18,460 18,470 712 - - 15,990 555 16,730 691 P110 MS 19,020 18,400 18,080 19,430 21,950 747 - - 14,870 675 13,630 671 N80 12,760 12,240 12,060 13,020 11,710 501 - - 10,810 490 9,910 537 P110 EC 21,840 20,910 20,540 22,080 23,860 849 - - 15,990 729 15,490 725 L80 5 23.20 23.11 0.478 6.791 3.919 N/A 12,760 12,240 12,060 13,020 13,500 501 - - 10,810 466 9,910 510 P110 HCE 22,340 20,910 20,540 22,080 23,860 849 - - 15,990 729 15,490 725 L80 1Cr 12,760 12,240 12,060 13,020 13,500 501 - - 10,810 466 9,910 510 C110 19,020 18,400 18,080 19,430 20,200 747 - - 14,870 621 13,630 617 L80 HC 13,960 12,240 12,060 13,020 13,500 501 - - 10,810 466 9,910 510 Q125 21,620 20,910 20,540 22,080 23,860 849 - - 15,990 729 15,490 725 L80 IRP 12,760 12,240 12,060 13,020 13,500 501 - - 10,810 466 9,910 510 Q125 HC 23,340 20,910 20,540 22,080 23,860 849 - - 15,990 729 15,490 725 L80 HCE 13,960 13,380 13,190 14,240 13,500 548 - - 11,830 466 10,840 510 Q125 HCE 23,340 22,590 22,190 23,850 24,890 917 - - 15,990 756 16,730 752 C90 14,360 13,770 13,560 14,650 15,740 564 - - 12,170 490 11,150 537 N80 14,400 14,000 13,730 14,720 13,510 565 - - 10,810 567 9,910 537 R95 15,150 14,530 14,320 15,460 15,010 595 - - 12,840 515 11,770 564 L80 14,400 14,000 13,730 14,720 15,610 565 - - 10,810 538 9,910 510 T95 15,150 14,530 14,320 15,460 16,630 595 - - 12,840 515 11,770 564 L80 1Cr 14,400 14,000 13,730 14,720 15,610 565 - - 10,810 538 9,910 510 T95 HC 15,950 14,530 14,320 15,460 16,630 595 - - 12,840 515 11,770 564 L80 HC 15,750 14,000 13,730 14,720 15,610 565 - - 10,810 538 9,910 510 T95 E 15,150 15,300 15,070 16,270 16,630 626 - - 13,520 515 12,390 564 L80 IRP 14,400 14,000 13,730 14,720 15,610 565 - - 10,810 538 9,910 510 T95 HCE 15,950 15,300 15,070 16,270 16,630 626 - - 13,520 515 12,390 564 L80 HCE 15,750 15,310 15,020 16,100 15,610 619 - - 11,830 538 10,840 510 P110 17,550 16,820 16,580 17,900 19,920 689 - - 14,870 613 13,630 671 C90 16,200 15,750 15,450 16,560 18,220 636 - - 12,170 567 11,150 537 P110 RY 17,550 16,820 16,580 17,900 19,920 689 - - 14,870 613 13,630 671 R95 17,100 16,630 16,300 17,480 17,360 672 - - 12,840 595 11,770 564 P110 MS 17,550 16,820 16,580 17,900 19,920 689 - - 14,870 613 13,630 671 T95 17,100 16,630 16,300 17,480 19,250 672 - - 12,840 595 11,770 564 P110 EC 19,940 19,120 18,840 20,340 21,650 783 - - 15,990 662 15,490 725 T95 HC 18,470 16,630 16,300 17,480 19,250 672 - - 12,840 595 11,770 564 P110 HCE 20,100 19,120 18,840 20,340 21,650 783 - - 15,990 662 15,490 725 T95 E 17,100 17,500 17,160 18,400 19,250 707 - - 13,520 595 12,390 564 C110 17,550 16,820 16,580 17,900 18,330 689 - - 14,870 564 13,630 617 T95 HCE 18,470 17,500 17,160 18,400 19,250 707 - - 13,520 595 12,390 564 Q125 19,940 19,120 18,840 20,340 21,650 783 - - 15,990 662 15,490 725 P110 19,800 19,250 18,880 20,240 23,050 778 - - 14,870 708 13,630 671 Q125 HC 21,540 19,120 18,840 20,340 21,650 783 - - 15,990 662 15,490 725 P110 RY 19,800 19,250 18,880 20,240 23,050 778 - - 14,870 708 13,630 671 Q125 HCE 21,540 20,650 20,340 21,970 22,590 846 - - 15,990 686 16,730 752 P110 MS 19,800 19,250 18,880 20,240 23,050 778 - - 14,870 708 13,630 671 N80 13,830 13,380 13,150 14,130 12,870 543 - - 10,810 540 9,910 537 P110 EC 22,500 21,880 21,450 23,000 25,050 884 - - 15,990 765 15,490 725 L80 13,830 13,380 13,150 14,130 14,870 543 - - 10,810 513 9,910 510 P110 HCE 23,140 21,880 21,450 23,000 25,050 884 - - 15,990 765 15,490 725 L80 1Cr 13,830 13,380 13,150 14,130 14,870 543 - - 10,810 513 9,910 510 C110 19,800 19,250 18,880 20,240 21,210 778 - - 14,870 652 13,630 617 L80 HC 15,130 13,380 13,150 14,130 14,870 543 - - 10,810 513 9,910 510 Q125 22,500 21,880 21,450 23,000 25,050 884 - - 15,990 765 15,490 725 L80 IRP 13,830 13,380 13,150 14,130 14,870 543 - - 10,810 513 9,910 510 Q125 HC 24,300 21,880 21,450 23,000 25,050 884 - - 15,990 765 15,490 725 L80 HCE 15,130 14,640 14,380 15,460 14,870 594 - - 11,830 513 10,840 510 Q125 HCE 24,300 23,630 23,170 24,840 26,140 954 - - 15,990 793 16,730 752 C90 15,560 15,060 14,790 15,900 17,350 611 - - 12,170 540 11,150 537 R95 16,430 15,890 15,610 16,780 16,530 645 - - 12,840 567 11,770 564 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties T95 16,430 15,890 15,610 16,780 18,330 645 - - 12,840 567 11,770 564 5 24.10 24.05 0.500 7.069 3.875 N/A 5 1/2 15.50 15.36 0.275 4.514 4.825 N/A 5 1/2 17.00 16.89 0.304 4.962 4.767 N/A Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength J55 4,040 4,810 4,790 5,300 4,840 248 4,810 202 4,810 217 4,810 300 K55 4,040 4,810 4,790 5,300 6,130 248 4,810 222 4,810 239 4,810 366 J55 4,910 5,320 5,290 5,830 5,370 273 5,320 229 5,320 247 5,320 329 pg. 48 / Vallourec USA Corporation / Performance Data 4 1/2” -7” Vallourec USA Corporation / Performance Data 4 1/2” -7” / pg. 49 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Casing Dimensions and Minimum Performance Properties Pipe Body Drift API ALT. (in) (in) 5 1/2 17.00 16.89 0.304 4.962 4.767 N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) T&C (in) PE (lb/ft) (in) (in2) API ALT. (in) (in) (psi) (psi) (psi) (kips) 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 4,910 5,320 5,290 5,830 6,800 273 5,320 252 5,320 272 5,320 402 P110 EC 12,090 14,360 14,240 15,590 15,950 729 - - 13,160 592 14,050 728 N80 6,290 7,740 7,690 8,480 7,250 397 7,740 323 7,740 348 7,740 446 P110 HCE 12,440 14,360 14,240 15,590 15,950 729 - - 13,160 592 14,050 728 L80 6,290 7,740 7,690 8,480 8,320 397 7,740 317 7,740 338 7,740 428 C110 11,110 12,640 12,530 13,720 13,500 641 - - 12,640 504 12,360 624 L80 1Cr 6,290 7,740 7,690 8,480 8,320 397 7,740 317 7,740 338 7,740 428 Q125 12,090 14,360 14,240 15,590 15,950 729 - - 13,160 592 14,050 728 L80 HC 6,630 7,740 7,690 8,480 8,320 397 7,740 317 7,740 338 7,740 428 Q125 HC 13,320 14,360 14,240 15,590 15,950 729 - - 13,160 592 14,050 728 L80 IRP 6,290 7,740 7,690 8,480 8,320 397 7,740 317 7,740 338 7,740 428 Q125 HCE 13,320 15,510 15,380 16,840 16,640 787 - - 13,160 614 15,180 761 L80 HCE 6,630 8,460 8,410 9,280 8,320 434 8,460 337 8,460 338 8,460 436 N80 11,160 10,560 10,450 11,370 10,030 530 - - 9,870 502 8,990 580 C90 6,730 8,710 8,650 9,540 9,680 447 8,710 349 8,710 356 8,710 456 L80 11,160 10,560 10,450 11,370 11,550 530 - - 9,870 489 8,990 551 R95 6,940 9,190 9,130 10,070 9,260 471 9,190 368 9,190 374 9,190 480 L80 1Cr 11,160 10,560 10,450 11,370 11,550 530 - - 9,870 489 8,990 551 T95 6,940 9,190 9,130 10,070 10,230 471 9,190 368 9,190 374 9,190 480 L80 HC 12,210 10,560 10,450 11,370 11,550 530 - - 9,870 489 8,990 551 T95 HC 8,470 9,190 9,130 10,070 10,230 471 9,190 368 9,190 374 9,190 480 L80 IRP 11,160 10,560 10,450 11,370 11,550 530 - - 9,870 489 8,990 551 T95 E 6,940 9,670 9,620 10,600 10,230 496 9,670 374 9,670 374 9,670 485 L80 HCE 12,210 11,550 11,430 12,430 11,550 580 - - 10,800 489 9,830 551 T95 HCE 8,470 9,670 9,620 10,600 10,230 496 9,670 374 9,670 374 9,670 485 C90 12,380 11,880 11,750 12,790 13,450 597 - - 11,110 514 10,120 580 7,480 10,640 10,580 11,660 12,250 546 10,640 430 10,640 445 10,640 568 R95 12,930 12,540 12,410 13,500 12,840 630 - - 11,730 540 10,680 609 P110 RY 7,480 10,640 10,580 11,660 12,250 546 10,640 430 10,640 445 10,640 568 T95 12,930 12,540 12,410 13,500 14,210 630 - - 11,730 540 10,680 609 T95 HC 13,480 12,540 12,410 13,500 14,210 630 - - 11,730 540 10,680 609 T95 E 12,930 13,200 13,060 14,210 14,210 663 - - 12,340 540 11,240 609 P110 HCE 9,040 12,090 12,020 13,260 13,310 620 12,090 481 12,090 481 12,090 620 T95 HCE 13,480 13,200 13,060 14,210 14,210 663 - - 12,340 540 11,240 609 Q125 P110 14,540 14,530 14,360 15,630 17,020 729 - - 13,160 643 12,360 725 Q125 HC 9,110 12,090 12,020 13,260 13,310 620 12,090 481 12,090 481 12,090 620 P110 RY 14,540 14,530 14,360 15,630 17,020 729 - - 13,160 643 12,360 725 Q125 HCE 9,110 13,060 12,980 14,320 13,890 670 13,060 498 13,060 498 13,060 648 P110 MS 14,540 14,530 14,360 15,630 17,020 729 - - 13,160 643 12,360 725 N80 8,830 9,190 9,110 9,980 8,670 466 - - 9,190 428 8,990 524 P110 EC 16,220 16,510 16,320 17,760 18,490 829 - - 13,160 694 14,050 783 L80 8,830 9,190 9,110 9,980 9,970 466 - - 9,190 416 8,990 503 P110 HCE 16,460 16,510 16,320 17,760 18,490 829 - - 13,160 694 14,050 783 L80 1Cr 8,830 9,190 9,110 9,980 9,970 466 - - 9,190 416 8,990 503 C110 14,540 14,530 14,360 15,630 15,660 729 - - 13,160 592 12,360 667 L80 HC 9,850 9,190 9,110 9,980 9,970 466 - - 9,190 416 8,990 503 Q125 16,060 16,510 16,320 17,760 18,490 829 - - 13,160 694 14,050 783 L80 IRP 8,830 9,190 9,110 9,980 9,970 466 - - 9,190 416 8,990 503 Q125 HC 17,610 16,510 16,320 17,760 18,490 829 - - 13,160 694 14,050 783 L80 HCE 9,850 10,050 9,970 10,910 9,970 510 - - 10,050 416 9,830 512 Q125 HCE 17,610 17,830 17,630 19,180 19,300 895 - - 13,160 720 15,180 812 P110 EC 8,840 12,090 12,020 13,260 13,310 620 12,090 481 12,090 481 12,090 620 5 1/2 20.00 19.83 0.361 5.828 4.653 N/A 5 1/2 23.00 22.56 0.415 6.630 4.545 N/A 7,890 12,090 12,020 13,260 13,310 620 12,090 481 12,090 481 12,090 620 C90 9,630 10,340 10,250 11,230 11,600 525 - - 10,340 438 10,120 536 N80 12,650 12,120 11,940 12,900 11,590 601 - - - - - - R95 10,020 10,910 10,820 11,850 11,080 554 - - 10,910 460 10,680 563 L80 12,650 12,120 11,940 12,900 13,360 601 - - - - - - T95 10,020 10,910 10,820 11,850 12,250 554 - - 10,910 460 10,680 563 L80 1Cr 12,650 12,120 11,940 12,900 13,360 601 - - - - - - T95 HC 11,130 10,910 10,820 11,850 12,250 554 - - 10,910 460 10,680 563 L80 HC 13,830 12,120 11,940 12,900 13,360 601 - - - - - - T95 E Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength (psi) 8rd SC K55 P110 MS 7,480 10,640 10,580 11,660 12,250 546 10,640 430 10,640 445 10,640 568 N/A (psi) PBYS P110 5 1/2 20.00 19.83 0.361 5.828 4.653 Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) 5 1/2 26.00 25.56 0.476 7.513 4.423 N/A 10,020 11,490 11,390 12,470 12,250 583 - - 11,490 460 11,240 569 L80 IRP 12,650 12,120 11,940 12,900 13,360 601 - - - - - - T95 HCE 11,130 11,490 11,390 12,470 12,250 583 - - 11,490 460 11,240 569 L80 HCE 13,830 13,250 13,060 14,110 13,360 657 - - - - - - P110 11,110 12,640 12,530 13,720 14,680 641 - - 12,640 548 12,360 667 C90 14,230 13,630 13,430 14,520 15,580 676 - - - - - - P110 RY 11,110 12,640 12,530 13,720 14,680 641 - - 12,640 548 12,360 667 R95 15,020 14,390 14,180 15,320 14,860 714 - - - - - - P110 MS 11,110 12,640 12,530 13,720 14,680 641 - - 12,640 548 12,360 667 T95 15,020 14,390 14,180 15,320 16,460 714 - - - - - - Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength pg. 50 / Vallourec USA Corporation / Performance Data 4 1/2” -7” Vallourec USA Corporation / Performance Data 4 1/2” -7” / pg. 51 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 5 1/2 26.00 25.56 0.476 7.513 4.423 5 1/2 26.80 26.73 0.500 7.854 4.375 5 1/2 29.70 29.67 0.562 8.718 4.251 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties N/A N/A N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) T95 HC 15,810 14,390 14,180 15,320 16,460 714 - - - - - - T95 E 15,020 15,150 14,930 16,130 16,460 751 - - - - - T95 HCE 15,810 15,150 14,930 16,130 16,460 751 - - - - P110 (psi) (psi) (psi) (psi) (psi) (kips) Weight Wall Area Pipe Body Drift BC T&C PE API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) L80 HC 16,050 14,310 14,020 15,010 15,970 697 - - - - - - - L80 IRP 14,680 14,310 14,020 15,010 15,970 697 - - - - - - - - L80 HCE 16,050 15,650 15,330 16,420 15,970 763 - - - - - - (in) (lb/ft) (in) (in2) (psi) (psi) (psi) (psi) (psi) (kips) 17,390 16,660 16,420 17,740 19,710 826 - - - - - - C90 16,510 16,090 15,770 16,890 18,650 785 - - - - - - P110 RY 17,390 16,660 16,420 17,740 19,710 826 - - - - - - R95 17,430 16,990 16,640 17,820 17,770 828 - - - - - - P110 MS 17,390 16,660 16,420 17,740 19,710 826 - - - - - - T95 17,430 16,990 16,640 17,820 19,710 828 - - - - - - P110 EC 19,760 18,930 18,660 20,160 21,420 939 - - - - - - T95 HC 18,920 16,990 16,640 17,820 19,710 828 - - - - - - P110 HCE 20,160 18,930 18,660 20,160 21,420 939 - - - - - - T95 E C110 17,390 16,660 16,420 17,740 18,140 826 - - - - - - Q125 19,760 18,930 18,660 20,160 21,420 939 - - - - - Q125 HC 21,340 18,930 18,660 20,160 21,420 939 - - - - Q125 HCE 21,340 20,450 20,150 21,770 22,350 1,014 - - - N80 13,220 12,730 12,520 13,500 12,200 628 - - - L80 13,220 12,730 12,520 13,500 14,080 628 - - L80 1Cr 13,220 12,730 12,520 13,500 14,080 628 - L80 HC 14,460 12,730 12,520 13,500 14,080 628 L80 IRP 13,220 12,730 12,520 13,500 14,080 628 17,430 17,880 17,520 18,760 19,710 872 - - - - - - T95 HCE 18,920 17,880 17,520 18,760 19,710 872 - - - - - - - P110 20,180 19,670 19,270 20,640 23,600 959 - - - - - - - - P110 RY 20,180 19,670 19,270 20,640 23,600 959 - - - - - - - - - P110 MS 20,180 19,670 19,270 20,640 23,600 959 - - - - - - - - - P110 EC 22,940 22,350 21,900 23,450 25,650 1,090 - - - - - - - - - - P110 HCE 23,340 22,350 21,900 23,450 25,650 1,090 - - - - - - - - - - - C110 20,180 19,670 19,270 20,640 21,720 959 - - - - - - - - - - - - Q125 22,940 22,350 21,900 23,450 25,650 1,090 - - - - - - - - - - - - Q125 HC 25,260 22,350 21,900 23,450 25,650 1,090 - - - - - - L80 HCE 14,460 13,920 13,700 14,760 14,080 687 - - - - - - Q125 HCE 25,260 24,140 23,650 25,330 26,760 1,177 - - - - - - C90 14,880 14,320 14,090 15,190 16,430 707 - - - - - - N80 16,120 15,910 15,510 16,510 15,490 766 - - - - - - R95 15,700 15,110 14,870 16,030 15,660 746 - - - - - - L80 16,120 15,910 15,510 16,510 17,930 766 - - - - - - T95 15,700 15,110 14,870 16,030 17,360 746 - - - - - - L80 1Cr 16,120 15,910 15,510 16,510 17,930 766 - - - - - - T95 HC 16,600 15,110 14,870 16,030 17,360 746 - - - - - - L80 HC 18,340 15,910 15,510 16,510 17,930 766 - - - - - - T95 E 15,700 15,910 15,650 16,870 17,360 785 - - - - - - L80 IRP 16,120 15,910 15,510 16,510 17,930 766 - - - - - - T95 HCE 16,600 15,910 15,650 16,870 17,360 785 - - - - - - L80 HCE 18,340 17,400 16,970 18,060 17,930 838 - - - - - - P110 18,180 17,500 17,220 18,560 20,790 864 - - - - - - C90 18,130 17,900 17,450 18,570 20,960 861 - - - - - - P110 RY 18,180 17,500 17,220 18,560 20,790 864 - - - - - - R95 19,140 18,890 18,420 19,610 19,940 909 - - - - - - P110 MS 18,180 17,500 17,220 18,560 20,790 864 - - - - - - T95 19,140 18,890 18,420 19,610 22,140 909 - - - - - - P110 EC 20,660 19,890 19,570 21,090 22,590 982 - - - - - - T95 HC 21,270 18,890 18,420 19,610 22,140 909 - - - - - - P110 HCE 21,060 19,890 19,570 21,090 22,590 982 - - - - - - T95 E 19,140 19,890 19,390 20,640 22,140 957 - - - - - - C110 18,180 17,500 17,220 18,560 19,130 864 - - - - - - T95 HCE 21,270 19,890 19,390 20,640 22,140 957 - - - - - - Q125 20,660 19,890 19,570 21,090 22,590 982 - - - - - - P110 22,160 21,880 21,330 22,700 26,520 1,053 - - - - - - Q125 HC 22,310 19,890 19,570 21,090 22,590 982 - - - - - - P110 MS 22,160 21,880 21,330 22,700 26,520 1,053 - - - - - Q125 HCE 22,310 21,480 21,130 22,780 23,570 1,060 - - - - - - P110 EC 25,180 24,860 24,240 25,800 28,820 1,197 - - - - - - N80 14,680 14,310 14,020 15,010 13,820 697 - - - - - - P110 HCE 25,580 24,860 24,240 25,800 28,820 1,197 - - - - - - L80 14,680 14,310 14,020 15,010 15,970 697 - - - - - - C110 22,160 21,880 21,330 22,700 24,400 1,053 - - - - - - L80 1Cr 14,680 14,310 14,020 15,010 15,970 697 - - - - - - Q125 25,180 24,860 24,240 25,800 28,820 1,197 - - - - - - 5 1/2 29.70 29.67 0.562 8.718 4.251 5 1/2 32.60 32.57 0.625 9.572 4.125 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A N/A pg. 52 / Vallourec USA Corporation / Performance Data 4 1/2” -7” Vallourec USA Corporation / Performance Data 4 1/2” -7” / pg. 53 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 5 1/2 32.60 32.57 0.625 9.572 4.125 5 1/2 35.70 35.35 0.687 10.388 4.001 6 5/8 24.00 23.60 0.352 6.937 5.796 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties N/A N/A N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC T&C PE API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) Q125 HC 28,490 24,860 24,240 25,800 28,820 1,197 - - - - - - T95 HCE 7,850 9,300 9,250 10,210 9,810 Q125 HCE 28,490 26,850 26,180 27,860 30,070 1,292 - - - - - - P110 N80 17,490 17,490 16,960 17,950 17,160 831 - - - - - - P110 RY 6,730 10,230 10,170 11,230 11,750 763 10,230 592 10,230 641 10,230 786 L80 (psi) (psi) (psi) (psi) (psi) (kips) (in) (lb/ft) (in) (in2) (psi) (psi) (psi) (psi) (psi) (kips) IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 694 9,300 526 9,300 546 9,300 674 6,730 10,230 10,170 11,230 11,750 763 10,230 592 10,230 641 10,230 786 17,490 17,490 16,960 17,950 19,890 831 - - - - - - L80 1Cr 17,490 17,490 16,960 17,950 19,890 831 - - - - - - P110 MS 6,730 10,230 10,170 11,230 11,750 763 10,230 592 10,230 641 10,230 786 L80 HC 20,320 17,490 16,960 17,950 19,890 831 - - - - - - P110 HCE 7,980 11,620 11,560 12,770 12,770 867 11,620 662 11,620 702 11,620 860 L80 IRP 17,490 17,490 16,960 17,950 19,890 831 - - - - - - C110 6,730 10,230 10,170 11,230 10,810 763 10,230 577 10,230 598 10,230 739 L80 HCE 20,320 19,130 18,550 19,630 19,890 909 - - - - - - Q125 7,020 11,620 11,560 12,770 12,770 867 11,620 662 11,620 702 11,620 860 C90 19,680 19,670 19,080 20,190 23,280 935 - - - - - - Q125 HC 8,850 11,620 11,560 12,770 12,770 867 11,620 662 11,620 702 11,620 860 R95 20,770 20,770 20,140 21,320 22,120 987 - - - - - - Q125 HCE 8,850 12,550 12,480 13,790 13,330 936 11,820 707 11,820 728 12,550 901 T95 20,770 20,770 20,140 21,320 24,590 987 - - - - - - T95 HC 23,580 20,770 20,140 21,320 24,590 987 - - - - - - T95 E 20,770 21,860 21,200 22,440 24,590 1,039 - - - - - - T95 HCE 23,580 21,860 21,200 22,440 24,590 1,039 - - - - - P110 24,050 24,050 23,320 24,680 29,460 1,143 - - - - P110 RY 24,050 24,050 23,320 24,680 29,460 1,143 - - - P110 MS 24,050 24,050 23,320 24,680 29,460 1,143 - - - P110 EC 27,330 27,320 26,500 28,050 32,010 1,298 - - P110 HCE 27,730 27,320 26,500 28,050 32,010 1,298 - C110 24,050 24,050 23,320 24,680 27,100 1,143 Q125 27,330 27,320 26,500 28,050 32,010 1,298 6 5/8 24.00 23.60 0.352 6.937 5.796 N/A P110 EC 7,580 11,620 11,560 12,770 12,770 867 11,620 662 11,620 702 11,620 860 J55 6,170 6,060 6,010 6,600 6,150 447 - - 6,060 415 6,060 531 K55 6,170 6,060 6,010 6,600 7,790 447 - - 6,060 454 6,060 643 N80 8,170 8,810 8,740 9,590 8,300 651 - - 8,810 586 8,810 721 - L80 8,170 8,810 8,740 9,590 9,540 651 - - 8,810 576 8,810 693 - - L80 1Cr 8,170 8,810 8,740 9,590 9,540 651 - - 8,810 576 8,810 693 - - - L80 HC 9,260 8,810 8,740 9,590 9,540 651 - - 8,810 576 8,810 693 - - - L80 IRP 8,170 8,810 8,740 9,590 9,540 651 - - 8,810 576 8,810 693 - - - - L80 HCE 9,260 9,640 9,560 10,490 9,540 712 - - 9,640 602 9,640 709 - - - - - C90 8,880 9,910 9,840 10,790 11,100 732 - - 9,910 633 9,910 742 - - - - - - R95 9,220 10,460 10,380 11,390 10,610 773 - - 10,460 665 10,460 780 - - - - - - T95 9,220 10,460 10,380 11,390 11,720 773 - - 10,460 665 10,460 780 Q125 HC 31,650 27,320 26,500 28,050 32,010 1,298 - - - - - - T95 HC 10,490 10,460 10,380 11,390 11,720 773 - - 10,460 665 10,460 780 Q125 HCE 31,650 29,510 28,620 30,290 33,400 1,402 - - - - - - T95 E 9,220 11,020 10,930 11,990 11,720 813 - - 11,020 665 11,020 790 6 5/8 28.00 27.67 0.417 8.133 5.666 N/A J55 4,560 5,110 5,090 5,620 5,160 382 5,110 314 5,110 340 5,110 453 T95 HCE 10,490 11,020 10,930 11,990 11,720 813 - - 11,020 665 11,020 790 K55 4,560 5,110 5,090 5,620 6,530 382 5,110 342 5,110 372 5,110 548 P110 10,160 12,120 12,020 13,190 14,040 895 - - 11,820 781 12,120 922 N80 5,760 7,440 7,400 8,170 6,960 555 7,440 443 7,440 481 7,440 615 P110 RY 10,160 12,120 12,020 13,190 14,040 895 - - 11,820 781 12,120 922 L80 5,760 7,440 7,400 8,170 7,990 555 7,440 436 7,440 473 7,440 592 P110 MS 10,160 12,120 12,020 13,190 14,040 895 - - 11,820 781 12,120 922 L80 1Cr 5,760 7,440 7,400 8,170 7,990 555 7,440 436 7,440 473 7,440 592 P110 EC 11,000 13,770 13,660 14,990 15,260 1,017 - - 11,820 855 13,770 1,008 L80 HC 7,170 7,440 7,400 8,170 7,990 555 7,440 436 7,440 473 7,440 592 P110 HCE 11,400 13,770 13,660 14,990 15,260 1,017 - - 11,820 855 13,770 1,008 L80 IRP 5,760 7,440 7,400 8,170 7,990 555 7,440 436 7,440 473 7,440 592 C110 10,160 12,120 12,020 13,190 12,920 895 - - 11,820 728 12,120 866 L80 HCE 7,170 8,140 8,090 8,940 7,990 607 8,140 464 8,140 494 8,140 604 Q125 11,000 13,770 13,660 14,990 15,260 1,017 - - 11,820 855 13,770 1,008 C90 6,140 8,370 8,320 9,190 9,290 624 8,370 481 8,370 520 8,370 633 Q125 HC 12,920 13,770 13,660 14,990 15,260 1,017 - - 11,820 855 13,770 1,008 R95 6,310 8,830 8,780 9,700 8,880 659 8,830 507 8,830 546 8,830 665 Q125 HCE 12,920 14,870 14,760 16,190 15,920 1,098 - - 11,820 887 14,780 1,057 T95 6,310 8,830 8,780 9,700 9,810 659 8,830 507 8,830 546 8,830 665 N80 10,320 10,040 9,940 10,840 9,500 734 - - 10,040 678 9,810 814 L80 10,320 10,040 9,940 10,840 10,940 734 - - 10,040 666 9,810 783 L80 1Cr 10,320 10,040 9,940 10,840 10,940 734 - - 10,040 666 9,810 783 T95 HC 7,850 8,830 8,780 9,700 9,810 659 8,830 507 8,830 546 8,830 665 T95 E 6,310 9,300 9,250 10,210 9,810 694 9,300 526 9,300 546 9,300 674 6 5/8 32.00 31.23 0.475 9.177 5.550 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A pg. 54 / Vallourec USA Corporation / Performance Data 4 1/2” -7” Vallourec USA Corporation / Performance Data 4 1/2” -7” / pg. 55 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 6 5/8 32.00 31.23 0.475 9.177 5.550 6 5/8 35.00 34.23 0.525 10.061 5.450 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties N/A N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) L80 HC 11,080 10,040 9,940 10,840 10,940 734 - - 10,040 666 9,810 783 L80 IRP 10,320 10,040 9,940 10,840 10,940 734 - - 10,040 666 9,810 783 L80 HCE 11,080 10,980 10,870 11,860 10,940 803 - - 10,980 696 10,730 800 C90 11,330 11,290 11,180 12,190 12,740 826 - - 11,290 732 11,040 837 R95 11,820 11,920 11,800 12,870 12,160 872 - - 11,820 769 11,660 880 T95 11,820 11,920 11,800 12,870 13,460 872 - - T95 HC 12,520 11,920 11,800 12,870 13,460 872 - T95 E (psi) (psi) (psi) (psi) (psi) (kips) Weight Wall Area Pipe Body Drift BC T&C (in) PE (lb/ft) (in) (in2) API ALT. (in) (in) Grade N/A PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 17,600 17,330 17,120 18,590 19,490 1,258 - - - - - - Q125 HC 18,700 17,330 17,120 18,590 19,490 1,258 - - - - - - Q125 HCE 18,700 18,720 18,490 20,070 20,340 1,358 - - - - - - (psi) Q125 6 5/8 35.00 34.23 0.525 10.061 5.450 Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (kips) J55 2,270 3,740 3,730 4,160 3,740 316 3,740 234 - - - - K55 2,270 3,740 3,730 4,160 4,730 316 3,740 254 - - - - 11,820 769 11,660 880 J55 3,270 4,360 4,340 4,820 4,370 366 4,360 284 4,360 313 4,360 432 - 11,820 769 11,660 880 K55 3,270 4,360 4,340 4,820 5,540 366 4,360 309 4,360 341 4,360 522 7 20.00 19.56 0.272 5.749 6.331 N/A 11,820 12,550 12,420 13,550 13,460 918 - - 11,820 769 12,270 891 N80 3,830 6,340 6,310 7,010 5,900 532 6,340 402 6,340 442 6,340 588 T95 HCE 12,520 12,550 12,420 13,550 13,460 918 - - 11,820 769 12,270 891 L80 3,830 6,340 6,310 7,010 6,770 532 6,340 396 6,340 435 6,340 565 P110 13,230 13,800 13,660 14,900 16,120 1,010 - - 11,820 904 13,500 1,040 L80 1Cr 3,830 6,340 6,310 7,010 6,770 532 6,340 396 6,340 435 6,340 565 P110 RY 13,230 13,800 13,660 14,900 16,120 1,010 - - 11,820 904 13,500 1,040 L80 HC 3,920 6,340 6,310 7,010 6,770 532 6,340 396 6,340 435 6,340 565 P110 MS 13,230 13,800 13,660 14,900 16,120 1,010 - - 11,820 904 13,500 1,040 L80 IRP 3,830 6,340 6,310 7,010 6,770 532 6,340 396 6,340 435 6,340 565 P110 EC 14,540 15,680 15,530 16,940 17,520 1,147 - - 11,820 989 14,780 1,138 L80 HCE 3,920 6,930 6,910 7,670 6,770 582 6,930 422 6,930 461 6,930 578 P110 HCE 14,940 15,680 15,530 16,940 17,520 1,147 - - 11,820 989 14,780 1,138 C90 4,030 7,130 7,100 7,890 7,860 599 7,130 437 7,130 479 7,130 605 C110 13,230 13,800 13,660 14,900 14,830 1,010 - - 11,820 842 13,500 977 R95 4,150 7,530 7,500 8,330 7,530 632 7,530 460 7,530 505 7,530 636 Q125 T95 4,150 7,530 7,500 8,330 8,310 632 7,530 460 7,530 505 7,530 636 5,440 7,530 7,500 8,330 8,310 632 7,530 460 7,530 505 7,530 636 4,150 7,930 7,890 8,770 8,310 666 7,930 477 7,930 509 7,930 645 14,540 15,680 15,530 16,940 17,520 1,147 - - 11,820 989 14,780 1,138 Q125 HC 15,800 15,680 15,530 16,940 17,520 1,147 - - 11,820 989 14,780 1,138 Q125 HCE 15,800 16,940 16,770 18,290 18,280 1,239 - - 11,820 1,025 14,780 1,192 N80 11,670 11,090 10,960 11,900 10,560 805 - - - - - - T95 HCE 5,440 7,930 7,890 8,770 8,310 666 7,930 477 7,930 509 7,930 645 L80 7 23.00 22.65 0.317 6.655 6.241 6.250 T95 HC T95 E 11,670 11,090 10,960 11,900 12,160 805 - - - - - - P110 4,440 8,720 8,680 9,640 9,950 732 8,720 537 8,720 590 8,720 752 L80 1Cr 11,670 11,090 10,960 11,900 12,160 805 - - - - - - P110 RY 4,440 8,720 8,680 9,640 9,950 732 8,720 537 8,720 590 8,720 752 L80 HC 12,770 11,090 10,960 11,900 12,160 805 - - - - - - P110 MS 4,440 8,720 8,680 9,640 9,950 732 8,720 537 8,720 590 8,720 752 L80 IRP 11,670 11,090 10,960 11,900 12,160 805 - - - - - - P110 EC 5,690 9,910 9,870 10,960 10,810 832 9,520 601 9,520 655 9,910 823 L80 HCE 12,770 12,130 11,990 13,010 12,160 880 - - - - - - P110 HCE 5,690 9,910 9,870 10,960 10,810 832 9,520 601 9,520 655 9,910 823 C90 13,130 12,480 12,330 13,380 14,170 905 - - - - - - C110 4,440 8,720 8,680 9,640 9,150 732 8,720 524 8,720 558 8,720 707 R95 13,860 13,170 13,010 14,130 13,530 956 - - - - - - Q125 4,650 9,910 9,870 10,960 10,810 832 9,520 601 9,520 655 9,910 823 T95 13,860 13,170 13,010 14,130 14,970 956 - - - - - - Q125 HC 5,760 9,910 9,870 10,960 10,810 832 9,520 601 9,520 655 9,910 823 T95 HC 14,590 13,170 13,010 14,130 14,970 956 - - - - - - Q125 HCE 5,760 10,700 10,660 11,840 11,280 898 9,520 642 9,520 679 10,700 863 T95 E 13,860 13,870 13,700 14,870 14,970 1,006 - - - - - - J55 4,330 4,980 4,950 5,470 5,010 415 4,980 334 4,980 367 4,980 490 T95 HCE 14,590 13,870 13,700 14,870 14,970 1,006 - - - - - - K55 4,330 4,980 4,950 5,470 6,350 415 4,980 364 4,980 401 4,980 592 P110 15,870 15,250 15,070 16,360 17,930 1,107 - - - - - - N80 5,410 7,240 7,200 7,960 6,770 604 7,240 472 7,240 519 7,240 667 P110 RY 15,870 15,250 15,070 16,360 17,930 1,107 - - - - - - L80 P110 MS 15,870 15,250 15,070 16,360 17,930 1,107 - - - - - - P110 EC 17,600 17,330 17,120 18,590 19,490 1,258 - - - - - P110 HCE 17,600 17,330 17,120 18,590 19,490 1,258 - - - - C110 - - - - 15,870 15,250 15,070 16,360 16,500 1,107 5,410 7,240 7,200 7,960 7,770 604 7,240 465 7,240 511 7,240 641 L80 1Cr 5,410 7,240 7,200 7,960 7,770 604 7,240 465 7,240 511 7,240 641 - L80 HC 5,520 7,240 7,200 7,960 7,770 604 7,240 465 7,240 511 7,240 641 - - L80 IRP 5,410 7,240 7,200 7,960 7,770 604 7,240 465 7,240 511 7,240 641 - - L80 HCE 5,520 7,920 7,880 8,710 7,770 661 7,920 495 7,920 541 7,920 656 7 26.00 25.69 0.362 7.549 6.151 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A Vallourec USA Corporation / Performance Data 4 1/2” -7” / pg. 57 pg. 56 / Vallourec USA Corporation / Performance Data 4 1/2” -7” Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) Grade 26.00 25.69 0.362 7.549 6.151 N/A (psi) (psi) (psi) (kips) 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) T&C (in) PE (lb/ft) (in) (in2) API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (kips) (psi) (kips) (psi) (kips) (psi) (kips) C90 5,740 8,150 8,100 8,960 9,030 679 8,150 513 8,150 563 8,150 687 N80 8,610 9,060 8,990 9,850 8,540 745 - - 9,060 672 8,460 823 R95 5,890 8,600 8,550 9,460 8,640 717 8,600 541 8,600 593 8,600 722 L80 8,610 9,060 8,990 9,850 9,820 745 - - 9,060 661 8,460 791 T95 5,890 8,600 8,550 9,460 9,540 717 8,600 541 8,600 593 8,600 722 L80 1Cr 8,610 9,060 8,990 9,850 9,820 745 - - 9,060 661 8,460 791 T95 HC 7,420 8,600 8,550 9,460 9,540 717 8,600 541 8,600 593 8,600 722 L80 HC 9,610 9,060 8,990 9,850 9,820 745 - - 9,060 661 8,460 791 T95 E 5,890 9,050 9,000 9,950 9,540 755 9,050 561 9,050 598 9,050 732 L80 IRP 8,610 9,060 8,990 9,850 9,820 745 - - 9,060 661 8,460 791 T95 HCE 7,420 9,050 9,000 9,950 9,540 755 9,050 561 9,050 598 9,050 732 L80 HCE 9,610 9,910 9,830 10,770 9,820 815 - - 9,520 701 9,250 810 6,230 9,960 9,900 10,950 11,430 830 9,520 631 9,520 693 9,960 853 C90 9,370 10,190 10,110 11,080 11,430 839 - - 9,520 729 9,510 847 P110 RY 6,230 9,960 9,900 10,950 11,430 830 9,520 631 9,520 693 9,960 853 R95 9,740 10,760 10,670 11,690 10,920 885 - - 9,520 768 10,040 891 P110 MS 6,230 9,960 9,900 10,950 11,430 830 9,520 631 9,520 693 9,960 853 T95 9,740 10,760 10,670 11,690 12,070 885 - - 9,520 768 10,040 891 P110 EC 8,030 11,310 11,250 12,440 12,420 944 9,520 707 9,520 769 11,310 934 T95 HC 10,910 10,760 10,670 11,690 12,070 885 - - 9,520 768 10,040 891 P110 HCE 8,260 11,310 11,250 12,440 12,420 944 9,520 707 9,520 769 11,310 934 9,740 11,330 11,230 12,310 12,070 932 - - 9,520 775 10,570 903 C110 6,230 9,960 9,900 10,950 10,510 830 9,520 616 9,520 655 T95 HCE 10,910 11,330 11,230 12,310 12,070 932 - - 9,520 775 10,570 903 Q125 6,450 11,310 11,250 12,440 12,420 944 9,520 707 9,520 769 11,310 934 P110 10,780 12,460 12,360 13,540 14,460 1,025 - - 9,520 897 11,630 1,053 Q125 HC 8,260 11,310 11,250 12,440 12,420 944 9,520 707 9,520 769 11,310 934 P110 RY 10,780 12,460 12,360 13,540 14,460 1,025 - - 9,520 897 11,630 1,053 Q125 HCE 8,260 12,220 12,150 13,440 12,960 1,019 9,520 755 9,520 798 11,790 979 P110 MS 10,780 12,460 12,360 13,540 14,460 1,025 - - 9,520 897 11,630 1,053 7 32.00 31.70 0.453 9.317 5.969 6.000 T95 E 9,960 802 N80 7,030 8,160 8,110 8,920 7,660 676 - - 8,160 597 8,160 746 P110 EC 11,710 14,160 14,040 15,390 15,710 1,165 - - 9,520 996 11,790 1,152 L80 7,030 8,160 8,110 8,920 8,800 676 - - 8,160 587 8,160 718 P110 HCE 12,500 14,160 14,040 15,390 15,710 1,165 - - 9,520 996 11,790 1,152 L80 1Cr 7,030 8,160 8,110 8,920 8,800 676 - - 8,160 587 8,160 718 C110 10,780 12,460 12,360 13,540 13,300 1,025 - - 9,520 848 11,630 990 L80 HC 8,140 8,160 8,110 8,920 8,800 676 - - 8,160 587 8,160 718 Q125 11,710 14,160 14,040 15,390 15,710 1,165 - - 9,520 996 11,790 1,152 L80 IRP 7,030 8,160 8,110 8,920 8,800 676 - - 8,160 587 8,160 718 Q125 HC 12,620 14,160 14,040 15,390 15,710 1,165 - - 9,520 996 11,790 1,152 L80 HCE 8,400 8,930 8,870 9,760 8,800 739 - - 8,930 623 8,930 734 Q125 HCE 12,620 15,290 15,160 16,620 16,400 1,258 - - 9,520 1,033 11,790 1,208 C90 7,580 9,180 9,120 10,040 10,230 760 - - 9,180 648 9,180 768 N80 10,190 9,960 9,860 10,760 9,430 814 - - 9,240 746 8,460 876 R95 7,840 9,690 9,630 10,590 9,780 803 - - 9,520 683 9,690 808 L80 10,190 9,960 9,860 10,760 10,850 814 - - 9,240 734 8,460 832 T95 7,840 9,690 9,630 10,590 10,810 803 - - 9,520 683 9,690 808 L80 1Cr 10,190 9,960 9,860 10,760 10,850 814 - - 9,240 734 8,460 832 9,300 9,690 9,630 10,590 10,810 803 - - 9,520 683 9,690 808 L80 HC 11,330 9,960 9,860 10,760 10,850 814 - - 9,240 734 8,460 832 7,840 10,200 10,130 11,150 10,810 845 - - 9,520 688 10,200 819 L80 IRP 10,190 9,960 9,860 10,760 10,850 814 - - 9,240 734 8,460 832 T95 HCE 9,300 10,200 10,130 11,150 10,810 845 - - 9,520 688 10,200 819 L80 HCE 11,330 10,890 10,790 11,770 10,850 890 - - 9,520 778 9,250 832 P110 C90 11,170 11,210 11,100 12,110 12,630 916 - - 9,520 809 9,510 876 R95 11,650 11,830 11,710 12,780 12,060 966 - - 9,520 853 10,040 920 T95 29.00 28.75 0.408 8.449 6.059 6.125 T95 E Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength (psi) PBYS T95 HC 7 Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) P110 7 Casing Dimensions and Minimum Performance Properties 8,530 11,220 11,150 12,270 12,950 929 - - 9,520 797 11,220 955 P110 RY 8,530 11,220 11,150 12,270 12,950 929 - - 9,520 797 11,220 955 P110 MS 8,530 11,220 11,150 12,270 12,950 929 - - 9,520 797 11,220 955 11,650 11,830 11,710 12,780 13,350 966 - - 9,520 853 10,040 920 P110 EC 9,580 12,750 12,670 13,940 14,070 1,056 - - 9,520 885 11,790 1,045 T95 HC 12,390 11,830 11,710 12,780 13,350 966 - - 9,520 853 10,040 920 P110 HCE 9,760 12,750 12,670 13,940 14,070 1,056 - - 9,520 885 11,790 1,045 T95 E 11,650 12,450 12,330 13,450 13,350 1,017 - - 9,520 860 10,570 920 C110 8,530 11,220 11,150 12,270 11,920 929 - - 9,520 754 11,220 898 T95 HCE 12,390 12,450 12,330 13,450 13,350 1,017 - - 9,520 860 10,570 920 Q125 9,110 12,750 12,670 13,940 14,070 1,056 - - 9,520 885 11,790 1,045 P110 13,030 13,700 13,560 14,800 15,990 1,119 - - 9,520 996 11,630 1,095 Q125 HC 9,760 12,750 12,670 13,940 14,070 1,056 - - 9,520 885 11,790 1,045 P110 RY 13,030 13,700 13,560 14,800 15,990 1,119 - - 9,520 996 11,630 1,095 Q125 HCE 9,760 13,770 13,680 15,050 14,690 1,141 - - 9,520 918 11,790 1,096 P110 MS 13,030 13,700 13,560 14,800 15,990 1,119 - - 9,520 996 11,630 1,095 7 35.00 34.61 0.498 10.172 5.879 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A Vallourec USA Corporation / Performance Data 4 1/2” -7” / pg. 59 pg. 58 / Vallourec USA Corporation / Performance Data 4 1/2” -7” Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) 7 7 7 Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 35.00 34.61 0.498 10.172 5.879 38.00 37.29 0.540 10.959 5.795 41.00 40.43 0.590 11.881 5.695 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties N/A N/A N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) P110 EC 14,310 15,560 15,410 16,810 17,370 1,272 - - 9,520 1,106 11,790 1,183 P110 HCE 14,720 15,560 15,410 16,810 17,370 1,272 - - C110 13,030 13,700 13,560 14,800 14,710 1,119 - Q125 (psi) (psi) (psi) (psi) (psi) (kips) Weight Wall Area Pipe Body Drift BC T&C PE API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) T95 HC 15,440 14,010 13,820 14,950 16,000 1,129 - - - - - - 9,520 1,106 11,790 1,183 T95 E 14,660 14,750 14,550 15,740 16,000 1,188 - - - - - - - 9,520 942 11,630 1,008 T95 HCE 15,440 14,750 14,550 15,740 16,000 1,188 - - - - - - (in) (lb/ft) (in) (in2) (psi) (psi) (psi) (psi) (psi) (kips) 14,320 15,560 15,410 16,810 17,370 1,272 - - 9,520 1,106 11,790 1,183 P110 16,980 16,230 16,000 17,320 19,160 1,307 - - - - - - Q125 HC 15,500 15,560 15,410 16,810 17,370 1,272 - - 9,520 1,106 11,790 1,183 P110 RY 16,980 16,230 16,000 17,320 19,160 1,307 - - - - - - Q125 HCE 15,500 16,810 16,640 18,160 18,130 1,373 - - 9,520 1,147 11,790 1,227 P110 MS 16,980 16,230 16,000 17,320 19,160 1,307 - - - - - - N80 11,390 10,800 10,680 11,600 10,260 877 - - 9,240 814 8,460 876 P110 EC 19,300 18,440 18,180 19,680 20,820 1,485 - - - - - - L80 7 41.00 40.43 0.590 11.881 5.695 N/A 11,390 10,800 10,680 11,600 11,820 877 - - 9,240 801 8,460 832 P110 HCE 19,300 18,440 18,180 19,680 20,820 1,485 - - - - - - L80 1Cr 11,390 10,800 10,680 11,600 11,820 877 - - 9,240 801 8,460 832 C110 16,980 16,230 16,000 17,320 17,630 1,307 - - - - - - L80 HC 13,090 10,800 10,680 11,600 11,820 877 - - 9,240 801 8,460 832 Q125 19,300 18,440 18,180 19,680 20,820 1,485 - - - - - - L80 IRP 11,390 10,800 10,680 11,600 11,820 877 - - 9,240 801 8,460 832 Q125 HC 20,840 18,440 18,180 19,680 20,820 1,485 - - - - - - L80 HCE 13,090 11,810 11,680 12,690 11,820 959 - - 9,520 849 9,250 832 Q125 HCE 20,840 19,910 19,640 21,250 21,730 1,604 - - - - - - C90 12,810 12,150 12,010 13,050 13,770 986 - - 9,520 883 9,510 876 N80 13,010 12,500 12,310 13,280 11,970 1,001 - - - - - - R95 13,430 12,830 12,680 13,780 13,140 1,041 - - 9,520 931 10,040 920 L80 13,010 12,500 12,310 13,280 13,810 1,001 - - - - - - T95 13,430 12,830 12,680 13,780 14,550 1,041 - - 9,520 931 10,040 920 L80 1Cr 13,010 12,500 12,310 13,280 13,810 1,001 - - - - - - T95 HC 13,700 12,830 12,680 13,780 14,550 1,041 - - 9,520 931 10,040 920 L80 HC 14,230 12,500 12,310 13,280 13,810 1,001 - - - - - - T95 E 13,430 13,500 13,340 14,500 14,550 1,096 - - 9,520 938 10,570 920 L80 IRP 13,010 12,500 12,310 13,280 13,810 1,001 - - - - - - T95 HCE 13,700 13,500 13,340 14,500 14,550 1,096 - - 9,520 938 10,570 920 L80 HCE 14,230 13,670 13,460 14,520 13,810 1,095 - - - - - - P110 15,130 14,850 14,680 15,950 17,430 1,206 - - 9,520 1,087 11,630 1,095 C90 14,640 14,060 13,850 14,940 16,110 1,127 - - - - - - P110 RY 15,130 14,850 14,680 15,950 17,430 1,206 - - 9,520 1,087 11,630 1,095 R95 15,450 14,840 14,610 15,770 15,360 1,189 - - - - - - P110 MS 15,130 14,850 14,680 15,950 17,430 1,206 - - 9,520 1,087 11,630 1,095 T95 15,450 14,840 14,610 15,770 17,020 1,189 - - - - - - T95 HC 16,260 14,840 14,610 15,770 17,020 1,189 - - - - - - 7 42.70 42.59 0.625 12.517 5.625 N/A P110 EC 16,740 16,880 16,680 18,130 18,940 1,370 - - 9,520 1,207 11,790 1,183 P110 HCE 16,900 16,880 16,680 18,130 18,940 1,370 - - 9,520 1,207 11,790 1,183 T95 E 15,450 15,630 15,380 16,600 17,020 1,252 - - - - - - C110 15,130 14,850 14,680 15,950 16,030 1,206 - - 9,520 1,028 11,630 1,008 T95 HCE 16,260 15,630 15,380 16,600 17,020 1,252 - - - - - - Q125 16,740 16,880 16,680 18,130 18,940 1,370 - - 9,520 1,207 11,790 1,183 P110 17,890 17,190 16,920 18,260 20,390 1,377 - - - - - - Q125 HC 17,770 16,880 16,680 18,130 18,940 1,370 - - 9,520 1,207 11,790 1,183 P110 RY 17,890 17,190 16,920 18,260 20,390 1,377 - - - - - - Q125 HCE 17,770 18,230 18,010 19,580 19,760 1,479 - - 9,520 1,251 11,790 1,227 P110 MS 17,890 17,190 16,920 18,260 20,390 1,377 - - - - - - N80 12,350 11,800 11,640 12,590 11,270 950 - - - - - - P110 EC 20,330 19,530 19,230 20,750 22,150 1,565 - - - - - - L80 12,350 11,800 11,640 12,590 12,990 950 - - - - - - P110 HCE 20,330 19,530 19,230 20,750 22,150 1,565 - - - - - - L80 1Cr 12,350 11,800 11,640 12,590 12,990 950 - - - - - - C110 17,890 17,190 16,920 18,260 18,760 1,377 - - - - - - L80 HC 13,510 11,800 11,640 12,590 12,990 950 - - - - - - Q125 20,330 19,530 19,230 20,750 22,150 1,565 - - - - - - L80 IRP 12,350 11,800 11,640 12,590 12,990 950 - - - - - - Q125 HC 21,950 19,530 19,230 20,750 22,150 1,565 - - - - - - L80 HCE 13,510 12,910 12,730 13,770 12,990 1,040 - - - - - - Q125 HCE 21,950 21,090 20,770 22,410 23,120 1,690 - - - - - - C90 13,890 13,280 13,090 14,170 15,140 1,069 - - - - - - R95 14,660 14,010 13,820 14,950 14,440 1,129- - - - - - T95 14,660 14,010 13,820 14,950 16,000 1,129 - - - - - - Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength pg. 60 / Vallourec USA Corporation / Performance Data 4 1/2” -7” Casing Dimensions and Minimum Performance Properties Performance Data 7 5/8" - 10 3/4" Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” / pg. 61 Performance Data 7 5/8" - 10 3/4" Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 7 5/8 26.40 25.59 0.328 7.519 6.844 N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) J55 2,890 4,140 4,130 4,590 4,150 414 4,140 315 4,140 346 4,140 483 K55 2,890 4,140 4,130 4,590 5,250 414 4,140 342 4,140 377 4,140 581 N80 3,400 6,020 6,000 6,680 5,600 602 6,020 446 6,020 490 6,020 659 L80 3,400 6,020 6,000 6,680 6,420 602 6,020 440 6,020 482 6,020 635 L80 1Cr 3,400 6,020 6,000 6,680 6,420 602 6,020 440 6,020 482 6,020 635 L80 HC 3,520 6,020 6,000 6,680 6,420 602 6,020 440 6,020 482 6,020 635 L80 IRP 3,400 6,020 6,000 6,680 6,420 602 6,020 440 6,020 482 6,020 635 L80 HCE 3,520 6,590 6,560 7,300 6,420 658 6,590 469 6,590 514 6,590 651 C90 3,610 6,780 6,750 7,510 7,450 677 6,780 485 6,780 532 6,780 681 R95 3,710 7,150 7,130 7,930 7,140 714 7,150 511 7,150 560 7,150 716 T95 3,710 7,150 7,130 7,930 7,880 714 7,150 511 7,150 560 7,150 716 T95 HC 4,760 7,150 7,130 7,930 7,880 714 7,150 511 7,150 560 7,150 716 T95 E 3,710 7,530 7,500 8,350 7,880 752 7,530 531 7,530 581 7,530 726 T95 HCE 4,760 7,530 7,500 8,350 7,880 752 7,530 531 7,530 581 7,530 726 P110 3,920 8,280 8,250 9,180 9,430 827 8,280 597 8,280 654 8,280 845 P110 MS 3,920 8,280 8,250 9,180 9,430 827 8,280 597 8,280 654 8,280 845 P110 EC 4,900 9,410 9,380 10,430 10,250 940 9,410 669 9,410 733 9,410 926 P110 HCE 5,210 9,410 9,380 10,430 10,250 940 9,410 669 9,410 733 9,410 926 C110 3,920 8,280 8,250 9,180 8,680 827 8,280 583 8,280 637 8,280 797 Q125 4,050 9,410 9,380 10,430 10,250 940 9,410 669 9,410 733 9,410 926 Q125 HC 5,210 9,410 9,380 10,430 10,250 940 9,410 669 9,410 733 9,410 926 Q125 HCE 5,210 10,160 10,130 11,270 10,700 1,015 10,160 714 10,160 775 10,160 972 7 5/8 29.70 29.06 0.375 8.541 6.750 N/A N80 4,790 6,890 6,850 7,590 6,420 683 - - 6,890 575 6,890 749 L80 4,790 6,890 6,850 7,590 7,370 683 - - 6,890 567 6,890 721 L80 1Cr 4,790 6,890 6,850 7,590 7,370 683 - - 6,890 567 6,890 721 L80 HC 4,830 6,890 6,850 7,590 7,370 683 - - 6,890 567 6,890 721 L80 IRP 4,790 6,890 6,850 7,590 7,370 683 - - 6,890 567 6,890 721 L80 HCE 4,830 7,530 7,500 8,300 7,370 747 - - 7,530 604 7,530 739 C90 5,030 7,750 7,710 8,540 8,570 769 - - 7,750 625 7,750 773 R95 5,130 8,180 8,140 9,010 8,200 811 - - 8,180 659 8,180 813 T95 5,130 8,180 8,140 9,010 9,050 811 - - 8,180 659 8,180 813 95 HC 6,650 8,180 8,140 9,010 9,050 811 - - 8,180 659 8,180 813 T95 E 5,130 8,610 8,570 9,490 9,050 854 - - 8,610 683 8,610 825 T95 HCE 6,650 8,610 8,570 9,490 9,050 854 - - 8,610 683 8,610 825 5,350 9,470 9,420 10,440 10,840 940 - - 9,470 769 9,470 960 P110 MS 5,350 9,470 9,420 10,440 10,840 940 - - 9,470 769 9,470 960 P110 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength pg. 62/ Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” / pg. 63 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 7 5/8 29.70 29.06 0.375 8.541 6.750 7 5/8 33.70 33.07 0.430 9.720 6.640 7 5/8 39.00 38.08 0.500 11.192 6.500 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties N/A N/A N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC T&C PE API ALT. (in) (in) Grade IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) P110 EC 7,360 10,760 10,710 11,860 11,780 1,068 - - 10,760 861 10,760 1,052 T95 E P110 HCE 7,580 10,760 10,710 11,860 11,780 1,068 - - C110 5,350 9,470 9,420 10,440 9,980 - Q125 (psi) (psi) (psi) (psi) (psi) (kips) 940 Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 10,000 11,480 11,380 12,460 12,240 1,119 - - 11,480 948 11,480 1,081 10,760 861 10,760 1,052 T95 HCE 11,120 11,480 11,380 12,460 12,240 1,119 - - 11,480 948 11,480 1,081 - 9,470 748 P110 11,080 12,620 12,520 13,710 14,660 1,231 - - 11,790 1,066 12,620 1,258 (in) (lb/ft) (in) (in2) 9,470 905 (psi) (psi) (psi) (psi) (psi) (kips) 5,670 10,760 10,710 11,860 11,780 1,068 - - 10,760 861 10,760 1,052 P110 MS 11,080 12,620 12,520 13,710 14,660 1,231 - - 11,790 1,066 12,620 1,258 Q125 HC 7,580 10,760 10,710 11,860 11,780 1,068 - - 10,760 861 10,760 1,052 P110 EC 12,180 14,340 14,220 15,580 15,930 1,399 - - 11,790 1,194 12,670 1,379 Q125 HCE 7,580 11,620 11,560 12,810 12,290 1,153 - - 11,620 911 11,620 1,104 P110 HCE 13,210 14,340 14,220 15,580 15,930 1,399 - - 11,790 1,194 12,670 1,379 N80 6,560 7,900 7,850 8,650 7,400 778 - - 7,900 674 7,900 852 C110 11,080 12,620 12,520 13,710 13,490 1,231 - - 11,790 1,038 12,620 1,186 L80 7 5/8 39.00 38.08 0.500 11.192 6.500 N/A 6,560 7,900 7,850 8,650 8,500 778 - - 7,900 664 7,900 820 Q125 12,060 14,340 14,220 15,580 15,930 1,399 - - 11,790 1,194 12,670 1,379 L80 1Cr 6,560 7,900 7,850 8,650 8,500 778 - - 7,900 664 7,900 820 Q125 HC 13,500 14,340 14,220 15,580 15,930 1,399 - - 11,790 1,194 12,670 1,379 L80 HC 6,930 7,900 7,850 8,650 8,500 778 - - 7,900 664 7,900 820 Q125 HCE 13,500 15,490 15,360 16,820 16,630 1,511 - - 11,790 1,264 12,670 1,447 L80 IRP 6,560 7,900 7,850 8,650 8,500 778 - - 7,900 664 7,900 820 N80 10,820 10,320 10,210 11,120 9,780 998 - - 10,320 906 9,790 1,093 L80 HCE 6,930 8,640 8,580 9,460 8,500 850 - - 8,640 708 8,640 841 L80 10,820 10,320 10,210 11,120 11,260 998 - - 10,320 891 9,790 1,053 C90 7,050 8,880 8,830 9,730 9,890 875 - - 8,880 733 8,880 880 L80 1Cr 10,820 10,320 10,210 11,120 11,260 998 - - 10,320 891 9,790 1,053 R95 7,270 9,380 9,320 10,270 9,450 923 - - 9,380 772 9,380 925 L80 HC 11,620 10,320 10,210 11,120 11,260 998 - - 10,320 891 9,790 1,053 T95 7,270 9,380 9,320 10,270 10,440 923 - - 9,380 772 9,380 925 L80 IRP 10,820 10,320 10,210 11,120 11,260 998 - - 10,320 891 9,790 1,053 T95 HC 8,780 9,380 9,320 10,270 10,440 923 - - 9,380 772 9,380 925 L80 HCE 11,620 11,290 11,170 12,160 11,260 1,091 - - 11,290 950 10,710 1,079 T95 E 7,270 9,870 9,810 10,810 10,440 972 - - 9,870 801 9,870 939 C90 11,890 11,610 11,490 12,510 13,120 1,122 - - 11,610 984 11,010 1,129 T95 HCE 8,780 9,870 9,810 10,810 10,440 972 - - 9,870 801 9,870 939 R95 12,410 12,250 12,120 13,210 12,520 1,185 - - 11,790 1,037 11,620 1,187 P110 7,870 10,860 10,790 11,890 12,510 1,069 - - 10,860 901 10,860 1,093 T95 12,410 12,250 12,120 13,210 13,860 1,185 - - 11,790 1,037 11,620 1,187 P110 MS 7,870 10,860 10,790 11,890 12,510 1,069 - - 10,860 901 10,860 1,093 T95 HC 12,960 12,250 12,120 13,210 13,860 1,185 - - 11,790 1,037 11,620 1,187 P110 EC 9,060 12,340 12,260 13,510 13,590 1,215 - - 11,790 1,009 12,340 1,197 T95 E 12,410 12,900 12,760 13,900 13,860 1,247 - - 11,790 1,075 12,240 1,205 P110 HCE 9,330 12,340 12,260 13,510 13,590 1,215 - - 11,790 1,009 12,340 1,197 T95 HCE 12,960 12,900 12,760 13,900 13,860 1,247 - - 11,790 1,075 12,240 1,205 C110 7,870 10,860 10,790 11,890 11,510 1,069 - - 10,860 877 10,860 1,030 P110 13,930 14,190 14,040 15,290 16,600 1,372 - - 11,790 1,210 12,670 1,402 Q125 7 5/8 42.80 42.43 0.562 12.470 6.376 N/A 8,340 12,340 12,260 13,510 13,590 1,215 - - 11,790 1,009 12,340 1,197 P110 MS 13,930 14,190 14,040 15,290 16,600 1,372 - - 11,790 1,210 12,670 1,402 Q125 HC 9,330 12,340 12,260 13,510 13,590 1,215 - - 11,790 1,009 12,340 1,197 P110 EC 15,350 16,120 15,950 17,380 18,040 1,559 - - 11,790 1,355 12,670 1,536 Q125 HCE 9,330 13,320 13,240 14,590 14,190 1,312 - - 11,790 1,068 12,670 1,257 P110 HCE 15,740 16,120 15,950 17,380 18,040 1,559 - - 11,790 1,355 12,670 1,536 N80 8,820 9,180 9,100 9,970 8,660 895 - - 9,180 798 9,180 981 C110 13,930 14,190 14,040 15,290 15,270 1,372 - - 11,790 1,178 12,670 1,321 L80 8,820 9,180 9,100 9,970 9,960 895 - - 9,180 786 9,180 945 Q125 15,350 16,120 15,950 17,380 18,040 1,559 - - 11,790 1,355 12,670 1,536 L80 1Cr 8,820 9,180 9,100 9,970 9,960 895 - - 9,180 786 9,180 945 Q125 HC 16,240 16,120 15,950 17,380 18,040 1,559 - - 11,790 1,355 12,670 1,536 L80 HC 9,420 9,180 9,100 9,970 9,960 895 - - 9,180 786 9,180 945 Q125 HCE 16,240 17,410 17,230 18,770 18,820 1,683 - - 11,790 1,434 12,670 1,612 L80 IRP 8,820 9,180 9,100 9,970 9,960 895 - - 9,180 786 9,180 945 N80 11,510 10,920 10,800 11,730 10,390 1,051 - - 10,490 962 9,790 1,152 L80 HCE 9,420 10,040 9,960 10,900 9,960 979 L80 - - 10,040 837 10,040 969 11,510 10,920 10,800 11,730 11,960 1,051 - - 10,490 947 9,790 1,109 C90 9,610 10,330 10,240 11,220 11,590 1,007 - - 10,330 867 10,330 1,013 L80 1Cr 11,510 10,920 10,800 11,730 11,960 1,051 - - 10,490 947 9,790 1,109 R95 10,000 10,900 10,810 11,840 11,070 1,063 - - 10,900 914 10,900 1,065 L80 HC 12,590 10,920 10,800 11,730 11,960 1,051 - - 10,490 947 9,790 1,109 T95 10,000 10,900 10,810 11,840 12,240 1,063 - - 10,900 914 10,900 1,065 L80 IRP 11,510 10,920 10,800 11,730 11,960 1,051 - - 10,490 947 9,790 1,109 T95 HC 11,120 10,900 10,810 11,840 12,240 1,063 - - 10,900 914 10,900 1,065 L80 HCE 12,590 11,950 11,810 12,830 11,960 1,150 - - 11,470 1,009 10,710 1,137 7 5/8 45.30 44.71 0.595 13.141 6.310 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A pg. 64 / Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” / pg. 65 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 7 5/8 45.30 44.71 0.595 13.141 6.310 7 5/8 47.10 46.77 0.625 13.744 6.250 7 5/8 51.20 50.95 0.687 14.974 6.126 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties N/A N/A N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) T&C (in) PE (lb/ft) (in) (in2) API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) C90 12,950 12,290 12,150 13,190 13,940 1,183 - - 11,790 1,045 11,010 1,189 L80 1Cr 13,120 12,610 12,420 13,390 13,950 1,198 - - - - - - R95 13,670 12,970 12,820 13,930 13,310 1,248 - - 11,790 1,101 11,620 1,251 L80 HC 14,350 12,610 12,420 13,390 13,950 1,198 - - - - - - T95 13,670 12,970 12,820 13,930 14,730 1,248 - - 11,790 1,101 11,620 1,251 L80 IRP 13,120 12,610 12,420 13,390 13,950 1,198 - - - - - - T95 HC 14,290 12,970 12,820 13,930 14,730 1,248 - - 11,790 1,101 11,620 1,251 L80 HCE 14,350 13,800 13,580 14,640 13,950 1,310 - - - - - - T95 E 13,670 13,660 13,490 14,660 14,730 1,314 - - 11,790 1,142 12,240 1,270 C90 14,760 14,190 13,970 15,060 16,270 1,348 - - - - - - T95 HCE 14,290 13,660 13,490 14,660 14,730 1,314 - - 11,790 1,142 12,240 1,270 R95 15,580 14,980 14,740 15,900 15,510 1,423 - - - - - - P110 15,440 15,020 14,840 16,120 17,640 1,445 - - 11,790 1,285 12,670 1,477 T95 15,580 14,980 14,740 15,900 17,190 1,423 - - - - - - P110 MS 15,440 15,020 14,840 16,120 17,640 1,445 - - 11,790 1,285 12,670 1,477 T95 HC 16,430 14,980 14,740 15,900 17,190 1,423 - - - - - - P110 EC 17,270 17,070 16,870 18,320 19,170 1,643 - - 11,790 1,439 12,670 1,619 T95 E 15,580 15,770 15,520 16,730 17,190 1,497 - - - - - - P110 HCE 17,270 17,070 16,870 18,320 19,170 1,643 - - 11,790 1,439 12,670 1,619 T95 HCE 16,430 15,770 15,520 16,730 17,190 1,497 - - - - - - C110 15,440 15,020 14,840 16,120 16,230 1,445 - - 11,790 1,251 12,670 1,392 P110 18,040 17,340 17,070 18,410 20,590 1,647 - - - - - - Q125 7 5/8 51.20 50.95 0.687 14.974 6.126 N/A 17,110 17,070 16,870 18,320 19,170 1,643 - - 11,790 1,439 12,670 1,619 P110 MS 18,040 17,340 17,070 18,410 20,590 1,647 - - - - - - Q125 HC 18,160 17,070 16,870 18,320 19,170 1,643 - - 11,790 1,439 12,670 1,619 P110 EC 20,500 19,710 19,400 20,920 22,370 1,872 - - - - - - Q125 HCE 18,160 18,440 18,220 19,790 20,000 1,774 - - 11,790 1,523 12,670 1,699 P110 HCE 20,500 19,710 19,400 20,920 22,370 1,872 - - - - - - N80 12,040 11,480 11,330 12,270 10,940 1,100 - - 10,490 1,013 9,790 1,205 C110 18,040 17,340 17,070 18,410 18,940 1,647 - - - - - - L80 12,040 11,480 11,330 12,270 12,610 1,100 - - 10,490 997 9,790 1,160 Q125 20,500 19,710 19,400 20,920 22,370 1,872 - - - - - - L80 1Cr 12,040 11,480 11,330 12,270 12,610 1,100 - - 10,490 997 9,790 1,160 Q125 HC 22,130 19,710 19,400 20,920 22,370 1,872 - - - - - - L80 HC 13,170 11,480 11,330 12,270 12,610 1,100 - - 10,490 997 9,790 1,160 Q125 HCE 22,130 21,290 20,950 22,590 23,340 2,022 - - - - - - L80 IRP 12,040 11,480 11,330 12,270 12,610 1,100 - - 10,490 997 9,790 1,160 N80 14,190 13,770 13,510 14,500 13,270 1,296 - - - - - - L80 HCE 13,170 12,550 12,390 13,420 12,610 1,203 - - 11,470 1,062 10,710 1,177 L80 14,190 13,770 13,510 14,500 15,330 1,296 - - - - - - C90 13,540 12,910 12,740 13,810 14,690 1,237 - - 11,790 1,100 11,010 1,239 L80 1Cr 14,190 13,770 13,510 14,500 15,330 1,296 - - - - - - R95 14,300 13,630 13,450 14,570 14,020 1,306 - - 11,790 1,159 11,620 1,301 L80 HC 15,520 13,770 13,510 14,500 15,330 1,296 - - - - - - T95 14,300 13,630 13,450 14,570 15,520 1,306 - - 11,790 1,159 11,620 1,301 L80 IRP 14,190 13,770 13,510 14,500 15,330 1,296 - - - - - - T95 HC 15,050 13,630 13,450 14,570 15,520 1,306 - - 11,790 1,159 11,620 1,301 L80 HCE 15,520 15,060 14,780 15,860 15,330 1,417 - - - - - - T95 E 14,300 14,340 14,160 15,340 15,520 1,374 - - 11,790 1,202 12,240 1,301 C90 15,960 15,490 15,200 16,310 17,890 1,458 - - - - - - T95 HCE 15,050 14,340 14,160 15,340 15,520 1,374 - - 11,790 1,202 12,240 1,301 R95 16,850 16,350 16,050 17,220 17,050 1,539 - - - - - - P110 16,550 15,780 15,570 16,880 18,600 1,512 - - 11,790 1,353 12,670 1,545 T95 16,850 16,350 16,050 17,220 18,900 1,539 - - - - - - P110 MS 16,550 15,780 15,570 16,880 18,600 1,512 - - 11,790 1,353 12,670 1,545 T95 HC 18,130 16,350 16,050 17,220 18,900 1,539 - - - - - - P110 EC 18,700 17,930 17,700 19,180 20,210 1,718 - - 11,790 1,515 12,670 1,673 T95 E 16,850 17,210 16,890 18,130 18,900 1,620 - - - - - - P110 HCE 18,700 17,930 17,700 19,180 20,210 1,718 - - 11,790 1,515 12,670 1,673 T95 HCE 18,130 17,210 16,890 18,130 18,900 1,620 - - - - - - C110 16,550 15,780 15,570 16,880 17,110 1,512 - - 11,790 1,317 12,670 1,425 P110 19,510 18,930 18,580 19,940 22,640 1,782 - - - - - - Q125 7 5/8 55.30 55.12 0.750 16.199 6.000 N/A 18,700 17,930 17,700 19,180 20,210 1,718 - - 11,790 1,515 12,670 1,673 P110 MS 19,510 18,930 18,580 19,940 22,640 1,782 - - - - - - Q125 HC 19,900 17,930 17,700 19,180 20,210 1,718 - - 11,790 1,515 12,670 1,673 P110 EC 22,170 21,520 21,110 22,660 24,610 2,025 - - - - - - Q125 HCE 19,900 19,360 19,110 20,710 21,080 1,856 - - 11,790 1,603 12,670 1,735 P110 HCE 22,470 21,520 21,110 22,660 24,610 2,025 - - - - - - N80 13,120 12,610 12,420 13,390 12,090 1,198 - - - - - - C110 19,510 18,930 18,580 19,940 20,830 1,782 - - - - - - L80 13,120 12,610 12,420 13,390 13,950 1,198 - - - - - - Q125 22,170 21,520 21,110 22,660 24,610 2,025 - - - - - - Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength pg. 66 / Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” / pg. 67 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 7 5/8 55.30 55.12 0.750 16.199 6.000 N/A 7 3/4 46.10 45.51 0.595 13.374 6.435 6.500 7 3/4 48.02 47.60 0.625 13.990 6.375 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) Q125 HC 23,950 21,520 21,110 22,660 24,610 2,025 - - - - - - Q125 HCE 23,950 23,240 22,800 24,470 25,670 2,187 - - - - - - N80 11,340 10,750 10,630 11,550 10,210 1,070 - - - - - - L80 (psi) (psi) (psi) (psi) (psi) (kips) Weight Wall Area Pipe Body Drift BC T&C (in) PE (lb/ft) (in) (in2) API ALT. (in) (in) 7 3/4 48.02 47.60 0.625 13.990 6.375 N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) P110 EC 18,160 17,640 17,420 18,890 19,860 1,749 - - - - - - P110 HCE 18,160 17,640 17,420 18,890 19,860 1,749 - - - - - - C110 16,310 15,520 15,330 16,620 16,810 1,539 - - - - - - (psi) (psi) (psi) (psi) (psi) (kips) 11,340 10,750 10,630 11,550 11,760 1,070 - - - - - - Q125 18,160 17,640 17,420 18,890 19,860 1,749 - - - - - - L80 1Cr 11,340 10,750 10,630 11,550 11,760 1,070 - - - - - - Q125 HC 19,320 17,640 17,420 18,890 19,860 1,749 - - - - - - L80 HC 12,400 10,750 10,630 11,550 11,760 1,070 - - - - - - Q125 HCE 19,320 19,050 18,810 20,400 20,720 1,889 - - - - - - L80 IRP 11,340 10,750 10,630 11,550 11,760 1,070 - - - - - - J55 2,530 3,930 3,920 4,360 3,930 503 3,930 372 3,930 417 3,930 579 L80 HCE 12,400 11,760 11,620 12,630 11,760 1,170 - - - - - - K55 2,530 3,930 3,920 4,360 4,980 503 3,930 402 3,930 452 3,930 690 C90 12,750 12,090 11,950 13,000 13,700 1,204 - - - - - - VST55 HC 2,850 5,000 4,980 5,550 5,240 640 5,000 528 5,000 591 5,000 792 R95 13,320 12,760 12,620 13,720 13,080 1,271 - - - - - - N80 3,050 5,710 5,700 6,350 5,300 732 5,710 528 5,710 591 5,710 792 T95 13,320 12,760 12,620 13,720 14,470 1,271 - - - - - - L80 3,050 5,710 5,700 6,350 6,080 732 5,710 521 5,710 583 5,710 764 T95 HC 13,900 12,760 12,620 13,720 14,470 1,271 - - - - - - 521 5,710 583 5,710 764 13,320 13,440 13,280 14,440 14,470 1,337 - - - - - - L80 1Cr 3,050 5,710 5,700 6,350 6,080 8 5/8 32.00 31.13 0.352 9.149 7.796 7.875 L80 HC 3,180 5,710 5,700 6,350 6,080 732 5,710 T95 E 732 5,710 521 5,710 583 5,710 764 T95 HCE 13,900 13,440 13,280 14,440 14,470 1,337 - - - - - - L80 IRP 3,050 5,710 5,700 6,350 6,080 732 5,710 521 5,710 583 5,710 764 P110 15,000 14,780 14,610 15,880 17,340 1,471 - - - - - - L80 HCE 3,180 6,250 6,230 6,940 6,080 801 6,250 556 6,250 622 6,250 787 P110 MS 15,000 14,780 14,610 15,880 17,340 1,471 - - - - - - C90 3,210 6,430 6,410 7,140 7,060 823 6,430 575 6,430 643 6,430 822 P110 EC 16,600 16,790 16,600 18,050 18,840 1,672 - - - - - - R95 3,290 6,780 6,760 7,540 6,760 869 6,780 607 6,780 678 6,780 864 P110 HCE 16,790 16,790 16,600 18,050 18,840 1,672 - - - - - - T95 3,290 6,780 6,760 7,540 7,460 869 6,780 607 6,780 678 6,780 864 C110 15,000 14,780 14,610 15,880 15,950 1,471 - - - - - - T95 HC 4,120 6,780 6,760 7,540 7,460 869 6,780 607 6,780 678 6,780 864 Q125 16,600 16,790 16,600 18,050 18,840 1,672 - - - - - - T95 E 3,290 7,140 7,120 7,930 7,460 915 7,140 630 7,140 704 7,140 879 Q125 HC 17,760 16,790 16,600 18,050 18,840 1,672 - - - - - - T95 HCE 4,120 7,140 7,120 7,930 7,460 915 7,140 630 7,140 704 7,140 879 Q125 HCE 17,760 18,140 17,930 19,490 19,660 1,806 - - - - - - J55 3,450 4,460 4,450 4,930 4,480 568 4,460 434 4,460 486 4,460 654 N80 11,860 11,290 11,150 12,090 10,750 1,119 - - - - - - K55 3,450 4,460 4,450 4,930 5,680 568 4,460 468 4,460 526 4,460 780 L80 11,860 11,290 11,150 12,090 12,390 1,119 - - - - - - VST55 HC 3,880 5,680 5,660 6,280 5,970 724 5,680 615 5,680 688 5,680 895 L80 1Cr 11,860 11,290 11,150 12,090 12,390 1,119 - - - - - - N80 4,100 6,490 6,470 7,180 6,050 827 6,490 615 6,490 688 6,490 895 L80 HC 12,970 11,290 11,150 12,090 12,390 1,119 - - - - - - L80 4,100 6,490 6,470 7,180 6,940 827 6,490 606 6,490 678 6,490 864 L80 IRP 11,860 11,290 11,150 12,090 12,390 1,119 - - - - - - L80 1Cr 4,100 6,490 6,470 7,180 6,940 827 6,490 606 6,490 678 6,490 864 L80 HCE 12,970 12,350 12,190 13,220 12,390 1,224 - - - - - - L80 HC C90 13,350 12,700 12,540 13,600 14,440 1,259 - - - - - - R95 14,090 13,410 13,240 14,360 13,780 1,329 - - - - - T95 14,090 13,410 13,240 14,360 15,260 1,329 - - - - T95 HC 14,830 13,410 13,240 14,360 15,260 1,329 - - - T95 E 14,090 14,110 13,940 15,110 15,260 1,399 - - - T95 HCE 14,830 14,110 13,940 15,110 15,260 1,399 - - P110 16,310 15,520 15,330 16,620 18,270 1,539 - P110 MS 16,310 15,520 15,330 16,620 18,270 1,539 - 4,220 6,490 6,470 7,180 6,940 827 6,490 606 6,490 678 6,490 864 L80 IRP 4,100 6,490 6,470 7,180 6,940 827 6,490 606 6,490 678 6,490 864 - L80 HCE 4,220 7,100 7,070 7,850 6,940 904 7,100 647 7,100 724 7,100 889 - - C90 4,250 7,300 7,270 8,070 8,060 930 7,300 670 7,300 749 7,300 928 - - - R95 4,360 7,710 7,680 8,520 7,710 982 7,710 706 7,710 789 7,710 976 - - - T95 4,360 7,710 7,680 8,520 8,520 982 7,710 706 7,710 789 7,710 976 - - - - T95 HC 5,780 7,710 7,680 8,520 8,520 982 7,710 706 7,710 789 7,710 976 - - - - - T95 E 4,360 8,120 8,080 8,970 8,520 1,034 8,120 734 8,120 820 8,120 993 - - - - - T95 HCE 5,780 8,120 8,080 8,970 8,520 1,034 8,120 734 8,120 820 8,120 993 8 5/8 36.00 35.17 0.400 10.336 7.700 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A pg. 68 / Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” / pg. 69 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) Grade N/A (psi) (psi) (psi) (psi) PBYS 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (kips) (psi) (kips) (psi) (kips) (psi) (kips) T&C (in) PE (lb/ft) (in) (in2) API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) Q125 HC 9,280 12,680 12,600 13,870 13,990 1,595 - - 10,370 1,330 11,230 1,562 10,370 1,421 11,230 1,642 (psi) (psi) (psi) (psi) (psi) (kips) N80 5,530 7,300 7,270 8,030 6,830 925 - - 7,300 788 7,300 1,001 L80 5,530 7,300 7,270 8,030 7,840 925 - - 7,300 776 7,300 966 Q125 HCE 9,280 13,700 13,610 14,980 14,600 1,723 - - L80 1Cr 5,530 7,300 7,270 8,030 7,840 925 - - 7,300 776 7,300 966 P110 3,840 8,210 8,180 9,110 9,350 1,241 - - - - - - L80 HC 5,790 7,300 7,270 8,030 7,840 925 - - 7,300 776 7,300 966 P110 MS 3,840 8,210 8,180 9,110 9,350 1,241 - - - - - - L80 IRP 5,530 7,300 7,270 8,030 7,840 925 - - 7,300 776 7,300 966 P110 EC 3,960 9,330 9,300 10,350 10,160 1,410 - - - - - - L80 HCE 5,790 7,990 7,950 8,780 7,840 1,011 - - 7,990 829 7,990 994 9 3/8 39.00 38.38 0.400 11.278 8.419 8.500 P110 HCE 4,820 9,330 9,300 10,350 10,160 1,410 - - - - - - C90 5,870 8,220 8,170 9,030 9,110 1,040 - - 8,220 858 8,220 1,038 Q125 3,960 9,330 9,300 10,350 10,160 1,410 - - - - - - R95 6,020 8,670 8,630 9,540 8,720 1,098 - - 8,670 904 8,670 1,092 Q125 HC 4,860 9,330 9,300 10,350 10,160 1,410 - - - - - - T95 6,020 8,670 8,630 9,540 9,630 1,098 - - 8,670 904 8,670 1,092 Q125 HCE 4,860 10,080 10,040 11,180 10,610 1,523 - - - - - - 7,560 8,670 8,630 9,540 9,630 1,098 - - 8,670 904 8,670 1,092 J55 2,020 3,520 3,510 3,920 3,510 564 3,520 394 3,520 453 3,520 639 6,020 9,130 9,080 10,040 9,630 1,156 - - 9,130 939 9,130 1,111 K55 2,020 3,520 3,510 3,920 4,450 564 3,520 423 3,520 489 3,520 755 T95 HCE 7,560 9,130 9,080 10,040 9,630 1,156 - - 9,130 939 9,130 1,111 VST55 HC 2,260 4,480 4,470 5,000 4,680 718 4,480 559 4,480 643 4,480 877 P110 6,400 10,040 9,990 11,040 11,530 1,271 - - 10,040 1,055 10,040 1,288 N80 2,370 5,120 5,110 5,710 4,740 820 5,120 559 5,120 643 5,120 877 P110 MS 6,400 10,040 9,990 11,040 11,530 1,271 - - 10,040 1,055 10,040 1,288 J55 2,570 3,950 3,940 4,390 3,950 630 3,950 452 3,950 520 3,950 714 P110 EC 8,140 11,410 11,350 12,550 12,530 1,445 - - 10,370 1,182 11,230 1,415 K55 2,570 3,950 3,940 4,390 5,000 630 3,950 486 3,950 561 3,950 843 P110 HCE 8,380 11,410 11,350 12,550 12,530 1,445 - - 10,370 1,182 11,230 1,415 VST55 HC 2,880 5,030 5,010 5,580 5,270 802 5,030 642 5,030 737 5,030 979 Q125 6,640 11,410 11,350 12,550 12,530 1,445 - - 10,370 1,182 11,230 1,415 N80 3,090 5,750 5,730 6,380 5,330 916 5,750 642 5,750 737 5,750 979 Q125 HC 8,450 11,410 11,350 12,550 12,530 1,445 - - 10,370 1,182 11,230 1,415 L80 3,090 5,750 5,730 6,380 6,110 916 5,750 633 5,750 727 5,750 947 Q125 HCE 8,450 12,330 12,260 13,550 13,080 1,560 - - 10,370 1,263 11,230 1,487 L80 1Cr 3,090 5,750 5,730 6,380 6,110 916 5,750 633 5,750 727 5,750 947 N80 6,950 8,120 8,060 8,880 7,620 1,021 - - 8,120 887 8,120 1,105 L80 HC 3,220 5,750 5,730 6,380 6,110 916 5,750 633 5,750 727 5,750 947 L80 6,950 8,120 8,060 8,880 8,750 1,021 - - 8,120 874 8,120 1,066 L80 IRP 3,090 5,750 5,730 6,380 6,110 916 5,750 633 5,750 727 5,750 947 L80 1Cr 6,950 8,120 8,060 8,880 8,750 1,021 - - 8,120 874 8,120 1,066 L80 HCE 3,220 6,280 6,260 6,980 6,110 1,002 6,280 677 6,280 777 6,280 978 L80 HC 7,360 8,120 8,060 8,880 8,750 1,021 - - 8,120 874 8,120 1,066 C90 3,260 6,460 6,440 7,180 7,100 1,031 6,460 700 6,460 804 6,460 1,021 L80 IRP 6,950 8,120 8,060 8,880 8,750 1,021 - - 8,120 874 8,120 1,066 R95 3,330 6,820 6,800 7,580 6,800 1,088 6,820 738 6,820 847 6,820 1,074 L80 HCE 7,360 8,880 8,820 9,710 8,750 1,117 - - 8,880 932 8,880 1,097 T95 3,330 6,820 6,800 7,580 7,500 1,088 6,820 738 6,820 847 6,820 1,074 C90 7,490 9,130 9,070 9,980 10,180 1,149 - - 9,130 965 9,130 1,146 T95 HC 4,190 6,820 6,800 7,580 7,500 1,088 6,820 738 6,820 847 6,820 1,074 R95 7,740 9,640 9,570 10,540 9,730 1,212 - - 9,640 1,017 9,640 1,206 T95 E 3,330 7,180 7,160 7,980 7,500 1,145 7,180 768 7,180 881 7,180 1,095 T95 T95 E 8 5/8 44.00 43.43 0.500 12.763 7.500 Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) 8 5/8 40.00 39.33 0.450 11.557 7.600 7.625 T95 HC 8 5/8 44.00 43.43 0.500 12.763 7.500 9 5/8 36.00 34.89 0.352 10.254 8.765 N/A N/A 9 5/8 40.00 38.97 0.395 11.454 8.679 8.750 7,740 9,640 9,570 10,540 10,750 1,212 - - 9,640 1,017 9,640 1,206 T95 HCE 4,190 7,180 7,160 7,980 7,500 1,145 7,180 768 7,180 881 7,180 1,095 T95 HC 9,210 9,640 9,570 10,540 10,750 1,212 - - 9,640 1,017 9,640 1,206 P110 3,470 7,900 7,870 8,770 8,980 1,260 7,900 861 7,900 988 7,900 1,266 T95 E 7,740 10,140 10,080 11,090 10,750 1,276 - - 10,140 1,056 10,140 1,226 P110 MS 3,470 7,900 7,870 8,770 8,980 1,260 7,900 861 7,900 988 7,900 1,266 T95 HCE 9,210 10,140 10,080 11,090 10,750 1,276 - - 10,140 1,056 10,140 1,226 P110 EC 3,530 8,980 8,950 9,970 9,760 1,432 8,980 966 8,980 1,108 8,980 1,393 P110 8,420 11,160 11,090 12,200 12,880 1,404 - - 10,370 1,186 11,160 1,423 P110 HCE 3,630 8,980 8,950 9,970 9,760 1,432 8,980 966 8,980 1,108 8,980 1,393 P110 MS 8,420 11,160 11,090 12,200 12,880 1,404 - - 10,370 1,186 11,160 1,423 Q125 3,530 8,980 8,950 9,970 9,760 1,432 8,980 966 8,980 1,108 8,980 1,393 P110 EC 8,980 12,680 12,600 13,870 13,990 1,595 - - 10,370 1,330 11,230 1,562 Q125 HC 3,630 8,980 8,950 9,970 9,760 1,432 8,980 966 8,980 1,108 8,980 1,393 P110 HCE 9,280 12,680 12,600 13,870 13,990 1,595 - - 10,370 1,330 11,230 1,562 Q125 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties 8,980 12,680 12,600 13,870 13,990 1,595 - - 10,370 1,330 11,230 1,562 Q125 HCE 3,630 9,700 9,660 10,770 10,190 1,546 9,670 1,033 9,700 1,185 9,160 1,467 9 5/8 43.50 42.73 0.435 12.559 8.599 8.625 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N80 3,810 6,330 6,300 7,000 5,890 1,005 - - 6,330 825 6,330 1,074 pg. 70/ Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” / pg. 71 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Casing Dimensions and Minimum Performance Properties Pipe Body Drift API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 3,810 6,330 6,300 7,000 6,750 1,005 - - 6,330 813 6,330 1,038 L80 1Cr 3,810 6,330 6,300 7,000 6,750 1,005 - - 6,330 813 L80 HC 3,950 6,330 6,300 7,000 6,750 1,005 - - L80 IRP 3,810 6,330 6,300 7,000 6,750 1,005 - L80 HCE 3,950 6,920 6,890 7,660 6,750 1,099 - C90 4,010 7,120 7,090 7,880 7,850 1,130 R95 T95 T&C PE API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) - - 9,700 1,361 9,160 1,650 6,330 1,038 Q125 5,630 10,730 10,680 11,830 11,750 1,697 9 5/8 47.00 46.18 0.472 13.572 8.525 8.625 Q125 HC 7,530 10,730 10,680 11,830 11,750 1,697 - - 9,700 1,361 9,160 1,650 6,330 813 6,330 1,038 Q125 HCE 7,530 11,590 11,530 12,770 12,260 1,832 - - 9,700 1,455 9,160 1,738 - 6,330 813 6,330 1,038 N80 6,620 7,930 7,880 8,680 7,430 1,244 - - 7,930 1,062 7,930 1,329 - 6,920 869 6,920 1,073 L80 6,620 7,930 7,880 8,680 8,540 1,244 - - 7,930 1,047 7,930 1,285 - - 7,120 899 7,120 1,119 L80 1Cr 6,620 7,930 7,880 8,680 8,540 1,244 - - 7,930 1,047 7,930 1,285 4,130 7,510 7,480 8,310 7,510 1,193 - - 7,510 948 7,510 1,178 L80 HC 7,000 7,930 7,880 8,680 8,540 1,244 - - 7,930 1,047 7,930 1,285 4,130 7,510 7,480 8,310 8,290 1,193 - - 7,510 948 7,510 1,178 L80 IRP 6,620 7,930 7,880 8,680 8,540 1,244 - - 7,930 1,047 7,930 1,285 5,410 7,510 7,480 8,310 8,290 1,193 - - 7,510 948 7,510 1,178 L80 HCE 7,000 8,670 8,620 9,490 8,540 1,360 - - 8,460 1,118 8,670 1,328 4,130 7,910 7,880 8,750 8,290 1,256 - - 7,910 985 7,910 1,200 C90 7,110 8,920 8,860 9,760 9,930 1,399 - - 8,460 1,157 8,920 1,386 T95 HCE 5,410 7,910 7,880 8,750 8,290 1,256 - - 7,910 985 7,910 1,200 R95 7,340 9,410 9,360 10,310 9,490 1,477 - - 8,460 1,220 9,160 1,458 P110 T95 (psi) L80 T95 HC 9 5/8 43.50 42.73 0.435 12.559 8.599 8.625 T95 E (psi) (psi) (psi) (psi) (kips) (in) (lb/ft) (in) (in2) (psi) (psi) (psi) (psi) (psi) (kips) 4,420 8,700 8,670 9,630 9,930 1,381 - - 8,700 1,105 8,700 1,388 7,340 9,410 9,360 10,310 10,490 1,477 - - 8,460 1,220 9,160 1,458 P110 MS 4,420 8,700 8,670 9,630 9,930 1,381 - - 8,700 1,105 8,700 1,388 T95 HC 8,850 9,410 9,360 10,310 10,490 1,477 - - 8,460 1,220 9,160 1,458 P110 EC 5,770 9,890 9,850 10,940 10,790 1,570 - - 9,700 1,240 9,160 1,527 T95 E 7,340 9,910 9,850 10,850 10,490 1,555 - - 8,460 1,267 9,160 1,486 P110 HCE 5,940 9,890 9,850 10,940 10,790 1,570 - - 9,700 1,240 9,160 1,527 T95 HCE 8,850 9,910 9,850 10,850 10,490 1,555 - - 8,460 1,267 9,160 1,486 C110 4,420 8,700 8,670 9,630 9,140 1,381 - - 8,700 1,082 8,700 1,317 P110 7,950 10,900 10,830 11,930 12,560 1,710 - - 9,700 1,422 9,160 1,718 Q125 4,620 9,890 9,850 10,940 10,790 1,570 - - 9,700 1,240 9,160 1,527 P110 MS 7,950 10,900 10,830 11,930 12,560 1,710 - - 9,700 1,422 9,160 1,718 Q125 HC 5,940 9,890 9,850 10,940 10,790 1,570 - - 9,700 1,240 9,160 1,527 P110 EC 9,140 12,390 12,310 13,560 13,650 1,943 - - 9,700 1,595 9,160 1,890 Q125 HCE 5,940 10,680 10,640 11,810 11,260 1,695 - - 9,700 1,325 9,160 1,608 P110 HCE 9,390 12,390 12,310 13,560 13,650 1,943 - - 9,700 1,595 9,160 1,890 N80 4,760 6,870 6,830 7,570 6,410 1,086 - - 6,870 905 6,870 1,161 C110 7,950 10,900 10,830 11,930 11,560 1,710 - - 9,700 1,393 9,160 1,630 L80 4,760 6,870 6,830 7,570 7,350 1,086 - - 6,870 893 6,870 1,122 Q125 8,440 12,390 12,310 13,560 13,650 1,943 - - 9,700 1,595 9,160 1,890 L80 1Cr 4,760 6,870 6,830 7,570 7,350 1,086 - - 6,870 893 6,870 1,122 Q125 HC 9,700 12,390 12,310 13,560 13,650 1,943 - - 9,700 1,595 9,160 1,890 L80 HC 4,940 6,870 6,830 7,570 7,350 1,086 - - 6,870 893 6,870 1,122 Q125 HCE 9,700 13,380 13,290 14,650 14,250 2,099 - - 9,700 1,706 9,160 1,991 L80 IRP 4,760 6,870 6,830 7,570 7,350 1,086 - - 6,870 893 6,870 1,122 N80 7,900 8,650 8,590 9,430 8,140 1,350 - - 8,460 1,167 8,650 1,443 L80 HCE 4,940 7,510 7,470 8,280 7,350 1,188 - - 7,510 954 7,510 1,159 L80 7,900 8,650 8,590 9,430 9,360 1,350 - - 8,460 1,151 8,650 1,396 C90 4,990 7,720 7,690 8,520 8,540 1,222 - - 7,720 987 7,720 1,210 L80 1Cr 7,900 8,650 8,590 9,430 9,360 1,350 - - 8,460 1,151 8,650 1,396 R95 5,090 8,150 8,110 8,990 8,170 1,289 - - 8,150 1,040 8,150 1,273 L80 HC 8,400 8,650 8,590 9,430 9,360 1,350 - - 8,460 1,151 8,650 1,396 9 5/8 47.00 46.18 0.472 13.572 8.525 8.625 T95 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength 9 5/8 53.50 52.90 0.545 15.546 8.379 8.500 5,090 8,150 8,110 8,990 9,020 1,289 - - 8,150 1,040 8,150 1,273 L80 IRP 7,900 8,650 8,590 9,430 9,360 1,350 - - 8,460 1,151 8,650 1,396 T95 HC 6,600 8,150 8,110 8,990 9,020 1,289 - - 8,150 1,040 8,150 1,273 L80 HCE 8,400 9,470 9,400 10,320 9,360 1,477 - - 8,460 1,229 9,160 1,442 T95 E 5,090 8,580 8,540 9,460 9,020 1,357 - - 8,460 1,081 8,580 1,297 9 5/8 58.40 57.44 0.595 16.879 8.279 8.375 C90 8,560 9,740 9,660 10,610 10,890 1,519 - - 8,460 1,272 9,160 1,505 T95 HCE 6,600 8,580 8,540 9,460 9,020 1,357- - - 8,460 1,081 8,580 1,297 R95 8,880 10,280 10,200 11,200 10,410 1,604 - - 8,460 1,341 9,160 1,583 P110 T95 5,300 9,440 9,400 10,410 10,810 1,493 - - 9,440 1,213 9,160 1,500 8,880 10,280 10,200 11,200 11,500 1,604 - - 8,460 1,341 9,160 1,583 P110 MS 5,300 9,440 9,400 10,410 10,810 1,493 - - 9,440 1,213 9,160 1,500 T95 HC 10,210 10,280 10,200 11,200 11,500 1,604 - - 8,460 1,341 9,160 1,583 P110 EC 7,310 10,730 10,680 11,830 11,750 1,697 - - 9,700 1,361 9,160 1,650 T95 E 8,880 10,820 10,740 11,790 11,500 1,688 - - 8,460 1,393 9,160 1,613 P110 HCE 7,530 10,730 10,680 11,830 11,750 1,697 - - 9,700 1,361 9,160 1,650 T95 HCE 10,210 10,820 10,740 11,790 11,500 1,688 - - 8,460 1,393 9,160 1,613 C110 - - 9,440 1,188 9,160 1,423 P110 - - 9,700 1,564 9,160 1,865 5,300 9,440 9,400 10,410 9,950 1,493 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength 9,770 11,900 11,810 12,970 13,780 1,857 pg. 72/ Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” / pg. 73 Casing Dimensions and Minimum Performance Properties OD Weight T&C Wall Area PE Casing Dimensions and Minimum Performance Properties Pipe Body Drift API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) P110 MS 9,770 11,900 11,810 12,970 13,780 1,857 - - 9,700 1,564 9,160 1,865 P110 EC 10,540 13,520 13,420 14,740 14,970 2,110 - - P110 HCE 10,740 13,520 13,420 14,740 14,970 2,110 9 5/8 58.40 57.44 0.595 16.879 8.279 8.375 C110 9,770 11,900 11,810 12,970 12,680 1,857 - (in) (lb/ft) (in) (in2) (psi) Q125 9 5/8 59.40 58.70 0.609 17.250 8.251 N/A (psi) (psi) (psi) (psi) (kips) 10,540 13,520 13,420 14,740 14,970 2,110 Weight Wall Area Pipe Body Drift BC T&C PE API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) T95 HC 10,570 10,520 10,440 11,450 11,790 1,725 - - - - - - 9,700 1,754 9,160 2,052 T95 E 9,320 11,080 10,990 12,050 11,790 1,816 - - - - - - - 9,700 1,754 9,160 2,052 T95 HCE 10,570 11,080 10,990 12,050 11,790 1,816 - - - - - - - - 9,700 1,531 9,160 1,770 P110 10,290 12,180 12,090 13,260 14,120 1,998 - - - - - - - - 9,700 1,754 9,160 2,052 P110 MS 10,290 12,180 12,090 13,260 14,120 1,998 - - - - - - - - - - - - (in) (lb/ft) (in) (in2) (psi) (psi) (psi) (psi) (psi) (kips) Q125 HC 10,980 13,520 13,420 14,740 14,970 2,110 - - 9,700 1,754 9,160 2,052 9 7/8 62.80 61.80 0.625 18.162 8.469 8.500 P110 EC 11,250 13,840 13,740 15,070 15,350 2,270 Q125 HCE 10,980 14,600 14,500 15,910 15,620 2,279 - - 9,700 1,875 9,160 2,161 P110 HCE 11,460 13,840 13,740 15,070 15,350 2,270 - - - - - - N80 8,250 8,860 8,790 9,640 8,340 1,380 - - - - - - C110 10,290 12,180 12,090 13,260 12,990 1,998 - - - - - - L80 8,250 8,860 8,790 9,640 9,590 1,380 - - - - - - Q125 11,140 13,840 13,740 15,070 15,350 2,270 - - - - - - L80 1Cr 8,250 8,860 8,790 9,640 9,590 1,380 - - - - - - Q125 HC 11,640 13,840 13,740 15,070 15,350 2,270 - - - - - - L80 HC 8,800 8,860 8,790 9,640 9,590 1,380 - - - - - - Q125 HCE 11,640 14,950 14,840 16,270 16,020 2,452 - - - - - - L80 IRP 8,250 8,860 8,790 9,640 9,590 1,380 - - - - - - N80 8,880 9,220 9,140 10,010 8,690 1,507 - - - - - - L80 HCE 8,800 9,690 9,610 10,540 9,590 1,509 - - - - - - L80 8,880 9,220 9,140 10,010 10,000 1,507 - - - - - - C90 8,970 9,970 9,890 10,850 11,160 1,552 - - - - - - L80 1Cr 8,880 9,220 9,140 10,010 10,000 1,507 - - - - - - R95 9,320 10,520 10,440 11,450 10,660 1,639 - - - - - - L80 HC 9,490 9,220 9,140 10,010 10,000 1,507 - - - - - - T95 9,320 10,520 10,440 11,450 11,790 1,639 - - - - - - L80 IRP 8,880 9,220 9,140 10,010 10,000 1,507 - - - - - - T95 HC 10,570 10,520 10,440 11,450 11,790 1,639 - - - - - - L80 HCE 9,490 10,080 9,990 10,940 10,000 1,648 - - - - - - T95 E 9,320 11,070 10,990 12,050 11,790 1,725 - - - - - - C90 9,680 10,370 10,280 11,260 11,630 1,695 - - - - - - T95 HCE 10,570 11,070 10,990 12,050 11,790 1,725 - - - - - - R95 10,070 10,940 10,850 11,880 11,120 1,790 - - - - - - P110 T95 10,280 12,180 12,090 13,260 14,120 1,897 - - - - - - 10,070 10,940 10,850 11,880 12,290 1,790 - - - - - - P110 MS 10,280 12,180 12,090 13,260 14,120 1,897 - - - - - - T95 HC 12,040 10,940 10,850 11,880 12,290 1,790 - - - - - - P110 EC 11,130 13,840 13,730 15,060 15,340 2,156 - - - - - - T95 E 10,070 11,520 11,420 12,510 12,290 1,884 - - - - - - P110 HCE 11,500 13,840 13,730 15,060 15,340 2,156 - - - - - - T95 HCE 12,040 11,520 11,420 12,510 12,290 1,884 - - - - - - C110 10,280 12,180 12,090 13,260 12,990 1,897 - - - - - - P110 11,170 12,670 12,560 13,760 14,720 2,072 - - - - - - Q125 11,130 13,840 13,730 15,060 15,340 2,156 - - - - - - P110 MS 11,170 12,670 12,560 13,760 14,720 2,072 - - - - - - Q125 HC 11,630 13,840 13,730 15,060 15,340 2,156 - - - - - - P110 EC 12,160 14,400 14,280 15,630 16,000 2,355 - - - - - - Q125 HCE 11,630 14,950 14,830 16,270 16,010 2,329 - - - - - - P110 HCE 12,560 14,400 14,280 15,630 16,000 2,355 - - - - - - N80 8,260 8,860 8,790 9,640 8,340 1,453 - - - - - - C110 11,170 12,670 12,560 13,760 13,540 2,072 - - - - - - L80 8,260 8,860 8,790 9,640 9,590 1,453 - - - - - - Q125 12,160 14,400 14,280 15,630 16,000 2,355 - - - - - - L80 1Cr 8,260 8,860 8,790 9,640 9,590 1,453 - - - - - - Q125 HC 12,760 14,400 14,280 15,630 16,000 2,355 - - - - - - L80 HC 9 7/8 65.30 64.10 0.650 18.838 8.419 8.500 8,800 8,860 8,790 9,640 9,590 1,453 - - - - - - Q125 HCE 12,760 15,550 15,420 16,880 16,690 2,543 - - - - - - 9 7/8 62.80 61.80 0.625 18.162 8.469 8.500 L80 IRP 8,260 8,860 8,790 9,640 9,590 1,453 - - - - - - N80 10,120 9,920 9,830 10,720 9,390 1,614 - - - - - - L80 HCE 8,800 9,690 9,620 10,550 9,590 1,589 - - - - - - L80 10,120 9,920 9,830 10,720 10,810 1,614 - - - - - - C90 8,980 9,970 9,890 10,850 11,160 1,635 - - - - - - L80 1Cr 10,120 9,920 9,830 10,720 10,810 1,614 - - - - - - R95 9,320 10,520 10,440 11,450 10,670 1,725 - - - - - - L80 HC 10,860 9,920 9,830 10,720 10,810 1,614 - - - - - - T95 9,320 10,520 10,440 11,450 11,790 1,725 - - - - - - L80 IRP 10,120 9,920 9,830 10,720 10,810 1,614 - - - - - - Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength 9 7/8 68.90 68.66 0.700 20.177 8.319 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A pg. 74/ Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” / pg. 75 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Casing Dimensions and Minimum Performance Properties Pipe Body Drift API ALT. (in) (in) 9 7/8 68.90 68.66 0.700 20.177 8.319 N/A 10 1/8 80.00 79.29 0.795 23.302 8.379 8.500 Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC T&C PE API ALT. (in) (in) Grade IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) L80 HCE 10,860 10,850 10,750 11,730 10,810 1,765 - - - - - - R95 C90 11,100 11,160 11,060 12,060 12,580 1,816 - - - - - - T95 R95 11,580 11,780 11,670 12,740 12,020 1,917 - - - - - - T95 (psi) (psi) (psi) (psi) (psi) (kips) (in) (lb/ft) (in) (in2) Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 2,590 6,190 6,170 6,890 6,140 1,236 6,190 808 - - 6,190 1,209 2,590 6,190 6,170 6,890 6,780 1,236 6,190 808 - - 6,190 1,209 T95 HC 3,180 6,190 6,170 6,890 6,780 1,236 6,190 808 - - 6,190 1,209 (psi) (psi) (psi) (psi) (psi) (kips) 11,580 11,780 11,670 12,740 13,300 1,917 - - - - - - T95 E 2,590 6,510 6,490 7,260 6,780 1,301 6,510 841 - - 6,510 1,236 T95 HC 12,340 11,780 11,670 12,740 13,300 1,917 - - - - - - T95 HCE 3,180 6,510 6,490 7,260 6,780 1,301 6,510 841 - - 6,510 1,236 T95 E 11,580 12,410 12,280 13,410 13,300 2,018 - - - - - - P110 2,610 7,160 7,140 7,980 8,120 1,431 7,160 941 - - 7,160 1,423 T95 HCE 12,340 12,410 12,280 13,410 13,300 2,018 - - - - - - P110 MS 2,610 7,160 7,140 7,980 8,120 1,431 7,160 941 - - 7,160 1,423 P110 10 3/4 45.50 44.26 0.400 13.006 9.794 9.875 12,940 13,650 13,510 14,750 15,930 2,219 - - - - - - P110 EC 3,450 8,140 8,120 9,070 8,820 1,626 7,890 1,057 - - 7,440 1,570 P110 MS 12,940 13,650 13,510 14,750 15,930 2,219 - - - - - - P110 HCE 3,450 8,140 8,120 9,070 8,820 1,626 7,890 1,057 - - 7,440 1,570 P110 EC 14,210 15,510 15,360 16,760 17,310 2,522 - - - - - - Q125 2,610 8,140 8,120 9,070 8,820 1,626 7,890 1,057 - - 7,440 1,570 P110 HCE 14,900 15,510 15,360 16,760 17,310 2,522 - - - - - - Q125 HC 3,260 8,140 8,120 9,070 8,820 1,626 7,890 1,057 - - 7,440 1,570 C110 12,940 13,650 13,510 14,750 14,650 2,219 - - - - - - Q125 HCE 3,260 8,790 8,770 9,800 9,210 1,756 7,890 1,132 - - 7,440 1,656 Q125 14,210 15,510 15,360 16,760 17,310 2,522 - - - - - - J55 2,700 4,030 4,020 4,470 4,030 801 4,030 565 - - 4,030 891 Q125 HC 15,000 15,510 15,360 16,760 17,310 2,522 - - - - - - K55 2,700 4,030 4,020 4,470 5,110 801 4,030 606 - - 4,030 1,043 Q125 HCE 15,000 16,750 16,580 18,100 18,060 2,724 - - - - - - VST55 HC 2,990 5,130 5,110 5,690 5,380 1,019 5,130 804 - - 5,130 1,228 P110 15,610 15,110 14,930 16,220 17,760 2,563 - - - - - - N80 3,220 5,860 5,840 6,500 5,440 1,165 5,860 804 - - 5,860 1,228 P110 MS 15,610 15,110 14,930 16,220 17,760 2,563 - - - - - - L80 3,220 5,860 5,840 6,500 6,240 1,165 5,860 794 - - 5,860 1,190 P110 EC 17,300 17,180 16,970 18,430 19,300 2,913 - - - - - - L80 1Cr 3,220 5,860 5,840 6,500 6,240 1,165 5,860 794 - - 5,860 1,190 P110 HCE 17,300 17,180 16,970 18,430 19,300 2,913 - - - - - - L80 HC 3,360 5,860 5,840 6,500 6,240 1,165 5,860 794 - - 5,860 1,190 C110 15,610 15,110 14,930 16,220 16,340 2,563 - - - - - - L80 IRP 3,220 5,860 5,840 6,500 6,240 1,165 5,860 794 - - 5,860 1,190 Q125 17,300 17,180 16,970 18,430 19,300 2,913 - - - - - - L80 HCE 3,360 6,410 6,390 7,110 6,240 1,274 6,410 850 - - 6,410 1,234 Q125 HC 18,370 17,180 16,970 18,430 19,300 2,913 - - - - - - C90 3,400 6,590 6,570 7,320 7,250 1,311 6,590 879 - - 6,590 1,287 Q125 HCE 18,370 18,550 18,330 19,900 20,140 3,146 - - - - - - R95 3,490 6,960 6,940 7,720 6,940 1,383 6,870 927 - - 6,960 1,354 T95 10 3/4 51.00 49.55 0.450 14.561 9.694 N/A J55 1,580 3,130 3,130 3,510 3,120 629 3,130 420 - - 3,130 700 3,490 6,960 6,940 7,720 7,660 1,383 6,870 927 - - 6,960 1,354 10 3/4 40.50 38.91 0.350 11.435 9.894 9.925 K55 1,580 3,130 3,130 3,510 3,950 629 3,130 450 - - 3,130 819 T95 HC 4,420 6,960 6,940 7,720 7,660 1,383 6,870 927 - - 6,960 1,354 VST55 HC 1,700 3,990 3,980 4,460 4,160 800 3,990 597 - - 3,990 964 T95 E 3,490 7,330 7,300 8,130 7,660 1,456 6,870 964 - - 7,330 1,383 J55 2,090 3,580 3,570 3,990 3,570 715 3,580 493 - - 3,580 796 T95 HCE 4,420 7,330 7,300 8,130 7,660 1,456 6,870 964 - - 7,330 1,383 K55 2,090 3,580 3,570 3,990 4,530 715 3,580 528 - - 3,580 931 P110 3,660 8,060 8,030 8,940 9,170 1,602 7,890 1,079 - - 7,440 1,594 VST55 HC 2,350 4,560 4,550 5,080 4,760 910 4,560 701 - - 4,560 1,097 P110 MS 3,660 8,060 8,030 8,940 9,170 1,602 7,890 1,079 - - 7,440 1,594 10 3/4 45.50 44.26 0.400 13.006 9.794 9.875 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N80 2,480 5,210 5,200 5,810 4,820 1,040 5,210 701 - - 5,210 1,097 P110 EC 4,510 9,160 9,130 10,160 9,970 1,820 7,890 1,212 - - 7,440 1,758 L80 2,480 5,210 5,200 5,810 5,530 1,040 5,210 692 - - 5,210 1,063 P110 HCE 4,510 9,160 9,130 10,160 9,970 1,820 7,890 1,212 - - 7,440 1,758 L80 1Cr 2,480 5,210 5,200 5,810 5,530 1,040 5,210 692 - - 5,210 1,063 Q125 3,740 9,160 9,130 10,160 9,970 1,820 7,890 1,212 - - 7,440 1,758 L80 HC 3,140 5,210 5,200 5,810 5,530 1,040 5,210 692 - - 5,210 1,063 Q125 HC 4,600 9,160 9,130 10,160 9,970 1,820 7,890 1,212 - - 7,440 1,758 L80 IRP 2,480 5,210 5,200 5,810 5,530 1,040 5,210 692 - - 5,210 1,063 Q125 HCE 4,600 9,890 9,860 10,970 10,400 1,966 7,890 1,297 - - 7,440 1,854 L80 HCE 3,140 5,700 5,680 6,350 5,530 1,138 5,700 741 - - 5,700 1,102 767 - - 5,860 1,149 C90 2,560 5,860 5,840 6,530 6,420 1,171 5,860 10 3/4 55.50 54.26 0.495 15.947 9.604 9.625 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N80 4,020 6,450 6,420 7,130 6,000 1,276 6,450 895 - - 6,450 1,345 L80 4,020 6,450 6,420 7,130 6,880 1,276 6,450 884 - - 6,450 1,303 pg. 76 / Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” / pg. 77 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 10 3/4 55.50 54.26 0.495 15.947 9.604 9.625 10 3/4 60.70 59.45 0.545 17.473 9.504 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) L80 1Cr 4,020 6,450 6,420 7,130 6,880 1,276 6,450 884 - - 6,450 1,303 L80 HC 4,130 6,450 6,420 7,130 6,880 1,276 6,450 884 - - 6,450 1,303 L80 IRP 4,020 6,450 6,420 7,130 6,880 1,276 6,450 884 - - L80 HCE 4,130 7,050 7,020 7,800 6,880 1,395 6,870 947 - C90 4,160 7,250 7,220 8,020 8,000 1,435 6,870 979 - R95 4,300 7,660 7,620 8,460 7,660 1,515 6,870 1,032 T95 T&C PE API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) Q125 HC 8,010 11,090 11,030 12,210 12,160 2,184 7,890 1,502 - - 7,440 2,109 Q125 HCE 8,010 11,980 11,920 13,190 12,690 2,359 7,890 1,608 - - 7,440 2,225 6,450 1,303 N80 6,310 7,750 7,700 8,490 7,260 1,519 6,870 1,096 - - 7,440 1,600 - 7,050 1,352 L80 6,310 7,750 7,700 8,490 8,340 1,519 6,870 1,082 - - 7,440 1,551 - 7,250 1,409 L80 1Cr 6,310 7,750 7,700 8,490 8,340 1,519 6,870 1,082 - - 7,440 1,551 - - 7,440 1,483 L80 HC 6,650 7,750 7,700 8,490 8,340 1,519 6,870 1,082 - - 7,440 1,551 4,300 7,660 7,620 8,460 8,450 1,515 6,870 1,032 - - 7,440 1,483 L80 IRP 6,310 7,750 7,700 8,490 8,340 1,519 6,870 1,082 - - 7,440 1,551 T95 HC 5,670 7,660 7,620 8,460 8,450 1,515 6,870 1,032 - - 7,440 1,483 L80 HCE 6,650 8,480 8,430 9,290 8,340 1,661 6,870 1,159 - - 7,440 1,609 T95 E 4,300 8,060 8,030 8,910 8,450 1,595 6,870 1,074 - - 7,440 1,515 C90 6,760 8,720 8,670 9,560 9,690 1,708 6,870 1,198 - - 7,440 1,677 T95 HCE 5,670 8,060 8,030 8,910 8,450 1,595 6,870 1,074 - - 7,440 1,515 R95 6,960 9,200 9,150 10,090 9,270 1,803 6,870 1,263 - - 7,440 1,765 P110 4,610 8,860 8,830 9,800 10,120 1,754 7,890 1,202 - - 7,440 1,745 T95 6,960 9,200 9,150 10,090 10,240 1,803 6,870 1,263 - - 7,440 1,765 P110 MS 4,610 8,860 8,830 9,800 10,120 1,754 7,890 1,202 - - 7,440 1,745 T95 HC 8,490 9,200 9,150 10,090 10,240 1,803 6,870 1,263 - - 7,440 1,765 P110 EC 6,130 10,070 10,030 11,140 11,000 1,993 7,890 1,350 - - 7,440 1,925 T95 E 6,960 9,690 9,630 10,620 10,240 1,898 6,870 1,314 - - 7,440 1,803 P110 HCE 6,310 10,070 10,030 11,140 11,000 1,993 7,890 1,350 - - 7,440 1,925 T95 HCE 8,490 9,690 9,630 10,620 10,240 1,898 6,870 1,314 - - 7,440 1,803 C110 4,610 8,860 8,830 9,800 9,310 1,754 7,890 1,180 - - 7,440 1,662 P110 7,510 10,650 10,590 11,680 12,270 2,088 7,890 1,471 - - 7,440 2,077 Q125 (psi) (psi) (psi) (psi) (psi) (kips) (in) (lb/ft) (in) (in2) 10 3/4 60.70 59.45 0.545 17.473 9.504 N/A 10 3/4 65.70 64.59 0.595 18.982 9.404 9.500 (psi) (psi) (psi) (psi) (psi) (kips) 4,850 10,070 10,030 11,140 11,000 1,993 7,890 1,350 - - 7,440 1,925 P110 MS 7,510 10,650 10,590 11,680 12,270 2,088 7,890 1,471 - - 7,440 2,077 Q125 HC 6,440 10,070 10,030 11,140 11,000 1,993 7,890 1,350 - - 7,440 1,925 P110 EC 8,900 12,110 12,040 13,270 13,330 2,373 7,890 1,652 - - 7,440 2,291 Q125 HCE 6,440 10,880 10,830 12,030 11,480 2,153 7,890 1,445 - - 7,440 2,031 P110 HCE 9,170 12,110 12,040 13,270 13,330 2,373 7,890 1,652 - - 7,440 2,291 N80 5,160 7,100 7,060 7,810 6,630 1,398 6,870 996 - - 7,100 1,473 C110 7,510 10,650 10,590 11,680 11,290 2,088 7,890 1,444 - - 7,440 1,979 L80 5,160 7,100 7,060 7,810 7,610 1,398 6,870 983 - - 7,100 1,428 Q125 7,920 12,110 12,040 13,270 13,330 2,373 7,890 1,652 - - 7,440 2,291 L80 1Cr 5,160 7,100 7,060 7,810 7,610 1,398 6,870 983 - - 7,100 1,428 Q125 HC 9,170 12,110 12,040 13,270 13,330 2,373 7,890 1,652 - - 7,440 2,291 L80 HC 5,390 7,100 7,060 7,810 7,610 1,398 6,870 983 - - 7,100 1,428 Q125 HCE 9,170 13,080 13,000 14,330 13,910 2,563 7,890 1,768 - - 7,440 2,417 L80 IRP 5,160 7,100 7,060 7,810 7,610 1,398 6,870 983 - - 7,100 1,428 N80 7,240 8,280 8,230 9,050 7,780 1,617 - - - - - - L80 HCE 5,390 7,760 7,720 8,550 7,610 1,529 6,870 1,053 - - 7,440 1,481 L80 7,240 8,280 8,230 9,050 8,940 1,617 - - - - - - C90 5,460 7,980 7,950 8,790 8,840 1,573 6,870 1,089 - - 7,440 1,544 L80 1Cr 7,240 8,280 8,230 9,050 8,940 1,617 - - - - - - R95 5,580 8,430 8,390 9,280 8,460 1,660 6,870 1,148 - - 7,440 1,625 L80 HC 7,680 8,280 8,230 9,050 8,940 1,617 - - - - - - T95 5,580 8,430 8,390 9,280 9,340 1,660 6,870 1,148 - - 7,440 1,625 L80 IRP 7,240 8,280 8,230 9,050 8,940 1,617 - - - - - - T95 HC 7,110 8,430 8,390 9,280 9,340 1,660 6,870 1,148 - - 7,440 1,625 L80 HCE 7,680 9,060 9,000 9,900 8,940 1,768 - - - - - - T95 E 5,580 8,870 8,830 9,770 9,340 1,747 6,870 1,195 - - 7,440 1,660 C90 7,820 9,320 9,250 10,180 10,400 1,819 - - - - - - T95 HCE 7,110 8,870 8,830 9,770 9,340 1,747 6,870 1,195 - - 7,440 1,660 R95 8,100 9,840 9,770 10,740 9,940 1,920 - - - - - - P110 5,880 9,760 9,710 10,740 11,190 1,922 7,890 1,337 - - 7,440 1,912 T95 8,100 9,840 9,770 10,740 10,980 1,920 - - - - - - P110 MS 5,880 9,760 9,710 10,740 11,190 1,922 7,890 1,337 - - 7,440 1,912 T95 HC 9,870 9,840 9,770 10,740 10,980 1,920 - - - - - - P110 EC 7,780 11,090 11,030 12,210 12,160 2,184 7,890 1,502 - - 7,440 2,109 T95 E 8,100 10,350 10,280 11,310 10,980 2,021 - - - - - - P110 HCE 8,010 11,090 11,030 12,210 12,160 2,184 7,890 1,502 - - 7,440 2,109 T95 HCE 9,870 10,350 10,280 11,310 10,980 2,021 - - - - - - C110 5,880 9,760 9,710 10,740 10,300 1,922 7,890 1,312 - - 7,440 1,821 P110 8,840 11,390 11,310 12,440 13,160 2,223 - - - - - - Q125 6,070 11,090 11,030 12,210 12,160 2,184 7,890 1,502 - - 7,440 2,109 P110 MS 8,840 11,390 11,310 12,440 13,160 2,223 - - - - - - 10 3/4 68.80 68.76 0.636 20.208 9.322 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N/A pg. 78 / Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” / pg. 79 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 10 3/4 68.80 68.76 0.636 20.208 9.322 10 3/4 73.20 72.40 0.672 21.276 9.250 10 3/4 79.20 78.59 0.734 23.096 9.126 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties N/A N/A N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC T&C PE API ALT. (in) (in) Grade IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) P110 EC 9,470 12,940 12,850 14,140 14,300 2,526 - - - - - - T95 E P110 HCE 9,810 12,940 12,850 14,140 14,300 2,526 - - - - - C110 8,840 11,390 11,310 12,440 12,100 2,223 - - - - Q125 (psi) (psi) (psi) (psi) (psi) (kips) Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 10,800 11,950 11,840 12,940 12,780 2,310 - - - - - - - T95 HCE 11,750 11,950 11,840 12,940 12,780 2,310 - - - - - - - - P110 12,030 13,140 13,020 14,240 15,300 2,541 - - - - - - (in) (lb/ft) (in) (in2) (psi) (psi) (psi) (psi) (psi) (kips) 9,470 12,940 12,850 14,140 14,300 2,526 - - - - - - P110 MS 12,030 13,140 13,020 14,240 15,300 2,541 - - - - - - Q125 HC 9,810 12,940 12,850 14,140 14,300 2,526 - - - - - - P110 EC 13,160 14,940 14,800 16,180 16,630 2,887 - - - - - - Q125 HCE 9,810 13,980 13,880 15,270 14,920 2,728 - - - - - - P110 HCE 13,840 14,940 14,800 16,180 16,630 2,887 - - - - - - N80 8,070 8,750 8,690 9,530 8,240 1,702 - - - - - - C110 12,030 13,140 13,020 14,240 14,080 2,541 - - - - - - L80 10 3/4 79.20 78.59 0.734 23.096 9.126 N/A 8,070 8,750 8,690 9,530 9,470 1,702 - - - - - - Q125 13,160 14,940 14,800 16,180 16,630 2,887 - - - - - - L80 1Cr 8,070 8,750 8,690 9,530 9,470 1,702 - - - - - - Q125 HC 13,840 14,940 14,800 16,180 16,630 2,887 - - - - - - L80 HC 8,590 8,750 8,690 9,530 9,470 1,702 - - - - - - Q125 HCE 13,840 16,130 15,990 17,470 17,350 3,118 - - - - - - L80 IRP 8,070 8,750 8,690 9,530 9,470 1,702 - - - - - - N80 10,920 10,380 10,270 11,180 9,840 1,994 - - - - - - L80 HCE 8,590 9,570 9,500 10,420 9,470 1,862 - - - - - - L80 10,920 10,380 10,270 11,180 11,330 1,994 - - - - - - C90 8,760 9,850 9,770 10,720 11,020 1,915 - - - - - - L80 1Cr 10,920 10,380 10,270 11,180 11,330 1,994 - - - - - - R95 9,090 10,390 10,310 11,320 10,530 2,021 - - - - - - L80 HC 11,740 10,380 10,270 11,180 11,330 1,994 - - - - - - T95 9,090 10,390 10,310 11,320 11,640 2,021 - - - - - - L80 IRP 10,920 10,380 10,270 11,180 11,330 1,994 - - - - - - T95 HC 10,380 10,390 10,310 11,320 11,640 2,021 - - - - - - L80 HCE 11,740 11,350 11,230 12,230 11,330 2,181 - - - - - - T95 E 9,090 10,940 10,860 11,910 11,640 2,128 - - - - - - C90 12,010 11,680 11,550 12,580 13,200 2,243 - - - - - - T95 HCE 10,380 10,940 10,860 11,910 11,640 2,128 - - - - - - R95 12,540 12,330 12,190 13,280 12,600 2,367 - - - - - - P110 10,010 12,030 11,940 13,100 13,940 2,340 - - - - - - T95 12,540 12,330 12,190 13,280 13,950 2,367 - - - - - - P110 MS 10,010 12,030 11,940 13,100 13,940 2,340 - - - - - - T95 HC 13,070 12,330 12,190 13,280 13,950 2,367 - - - - - - P110 EC 10,820 13,670 13,570 14,890 15,150 2,660 - - - - - - T95 E 12,540 12,970 12,840 13,980 13,950 2,492 - - - - - - P110 HCE 11,290 13,670 13,570 14,890 15,150 2,660 - - - - - - T95 HCE 13,070 12,970 12,840 13,980 13,950 2,492 - - - - - - C110 10,010 12,030 11,940 13,100 12,830 2,340 - - - - - - P110 14,080 14,270 14,120 15,380 16,700 2,741 - - - - - - Q125 10 3/4 85.30 84.80 0.797 24.921 9.000 N/A 10,820 13,670 13,570 14,890 15,150 2,660 - - - - - - P110 MS 14,080 14,270 14,120 15,380 16,700 2,741 - - - - - - Q125 HC 11,290 13,670 13,570 14,890 15,150 2,660 - - - - - - P110 EC 15,530 16,220 16,050 17,470 18,150 3,115 - - - - - - Q125 HCE 11,290 14,770 14,660 16,080 15,810 2,872 - - - - - - P110 HCE 15,870 16,220 16,050 17,470 18,150 3,115 - - - - - - N80 9,480 9,560 9,470 10,350 9,030 1,848 - - - - - - C110 14,080 14,270 14,120 15,380 15,370 2,741 - - - - - - L80 9,480 9,560 9,470 10,350 10,390 1,848 - - - - - - Q125 15,530 16,220 16,050 17,470 18,150 3,115 - - - - - - L80 1Cr 9,480 9,560 9,470 10,350 10,390 1,848 - - - - - - Q125 HC 16,440 16,220 16,050 17,470 18,150 3,115 - - - - - - L80 HC 10,290 9,560 9,470 10,350 10,390 1,848 - - - - - - Q125 HCE 16,440 17,520 17,330 18,870 18,940 3,364 - - - - - - L80 IRP 9,480 9,560 9,470 10,350 10,390 1,848 - - - - - - L80 HCE 10,290 10,460 10,360 11,330 10,390 2,021 - - - - - - C90 10,370 10,750 10,660 11,650 12,090 2,079 - - - - - - R95 10,800 11,350 11,250 12,300 11,550 2,194 - - - - - - T95 10,800 11,350 11,250 12,300 12,780 2,194 - - - - - - T95 HC 11,750 11,350 11,250 12,300 12,780 2,194 - - - - - - Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength pg. 80 / Vallourec USA Corporation / Performance Data 7 5/8” -10 3/4” Casing Dimensions and Minimum Performance Properties Performance Data 11 3/4" - 26" Vallourec USA Corporation / Performance Data 11 3/4” - 26” / pg. 81 Performance Data 11 3/4" - 26" Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 11 3/4 47.00 45.60 0.375 13.401 10.844 N/A 11 3/4 54.00 52.62 0.435 15.463 10.724 N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) J55 1,510 3,070 3,070 3,440 3,050 737 3,070 477 - - 3,070 807 K55 1,510 3,070 3,070 3,440 3,870 737 3,070 509 - - 3,070 935 J55 2,070 3,560 3,550 3,970 3,560 850 3,560 568 - - 3,560 931 K55 2,070 3,560 3,550 3,970 4,500 850 3,560 606 - - 3,560 1,079 J55 2,660 4,010 3,990 4,450 4,010 951 4,010 649 - - 4,010 1,042 K55 2,660 4,010 3,990 4,450 5,080 951 4,010 693 - - 4,010 1,208 N80 3,180 5,830 5,810 6,470 5,410 1,384 5,810 924 - - 5,830 1,440 L80 3,180 5,830 5,810 6,470 6,200 1,384 5,810 913 - - 5,830 1,399 L80 1Cr 3,180 5,830 5,810 6,470 6,200 1,384 5,810 913 - - 5,830 1,399 L80 HC 4,400 5,830 5,810 6,470 6,200 1,384 5,810 913 - - 5,830 1,399 L80 IRP 3,180 5,830 5,810 6,470 6,200 1,384 5,810 913 - - 5,830 1,399 L80 HCE 4,400 6,370 6,350 7,070 6,200 1,514 5,810 978 - - 6,300 1,456 C90 3,360 6,550 6,530 7,280 7,200 1,557 5,810 1,011 - - 6,300 1,517 11 3/4 60.00 58.87 0.489 17.300 10.616 10.625 R95 3,440 6,920 6,900 7,680 6,900 1,643 5,810 1,066 - - 6,300 1,596 T95 3,440 6,920 6,900 7,680 7,610 1,643 5,810 1,066 - - 6,300 1,596 T95 HC 4,350 6,920 6,900 7,680 7,610 1,643 5,810 1,066 - - 6,300 1,596 T95 E 3,500 7,280 7,260 8,080 7,610 1,730 5,810 1,110 - - 6,300 1,635 T95 HCE 4,350 7,280 7,260 8,080 7,610 1,730 5,810 1,110 - - 6,300 1,635 P110 3,610 8,010 7,980 8,890 9,120 1,903 6,670 1,242 - - 6,300 1,877 P110 MS 3,610 8,010 7,980 8,890 9,120 1,903 6,670 1,242 - - 6,300 1,877 P110 HCE 4,490 9,100 9,070 10,100 9,910 2,162 6,670 1,395 - - 6,300 2,074 Q125 3,680 9,100 9,070 10,100 9,910 2,162 6,670 1,395 - - 6,300 2,074 Q125 HC 4,520 9,100 9,070 10,100 9,910 2,162 6,670 1,395 - - 6,300 2,074 6,300 2,192 11 3/4 65.00 64.03 0.534 18.816 10.526 10.625 Q125 HCE 4,520 9,830 9,800 10,910 10,340 2,335 6,670 1,494 - - J55 3,290 4,370 4,360 4,840 4,390 1,035 - - - - - - K55 3,290 4,370 4,360 4,840 5,560 1,035 - - - - - - N80 3,870 6,360 6,340 7,040 5,920 1,505 - - - - - - L80 3,870 6,360 6,340 7,040 6,790 1,505 - - - - - - L80 1Cr 3,870 6,360 6,340 7,040 6,790 1,505 - - - - - - L80 HC 5,400 6,360 6,340 7,040 6,790 1,505 - - - - - - L80 IRP 3,870 6,360 6,340 7,040 6,790 1,505 - - - - - - L80 HCE 5,400 6,960 6,930 7,700 6,790 1,646 - - - - - - C90 4,060 7,160 7,130 7,920 7,890 1,693 - - - - - - R95 4,180 7,560 7,530 8,360 7,550 1,788 - - - - - - T95 4,180 7,560 7,530 8,360 8,340 1,788 - - - - - - 5,490 7,560 7,530 8,360 8,340 1,788 - - - - - - T95 HC Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength pg. 82 / Vallourec USA Corporation / Performance Data 11 3/4” - 26” Vallourec USA Corporation / Performance Data 11 3/4” - 26” / pg. 83 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) Grade 11 3/4 65.00 64.03 0.534 18.816 10.526 10.625 11 3/4 71.00 69.48 0.582 20.420 10.430 N/A 11 3/4 75.00 73.54 0.618 21.613 10.358 N/A Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC T&C PE API ALT. (in) (in) Grade IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 4,280 7,950 7,920 8,800 8,340 1,882 - - - - - - C90 T95 HCE 5,490 7,950 7,920 8,800 8,340 1,882 - - - - - - P110 4,480 8,750 8,710 9,680 9,990 2,070 - - - - - - P110 MS 4,480 8,750 8,710 9,680 9,990 2,070 - - - - - - P110 HCE 5,770 9,940 9,900 11,000 10,850 2,352 - - - - - - Q125 4,690 9,940 9,900 11,000 10,850 2,352 - - - - - - Q125 HC 5,810 9,940 9,900 11,000 10,850 2,352 - - - - - Q125 HCE 5,810 10,740 10,690 11,880 11,320 2,540 - - - - J55 3,970 4,770 4,740 5,250 4,790 1,123 - - - - K55 3,970 4,770 4,740 5,250 6,070 1,123 - - - N80 4,880 6,930 6,900 7,640 6,470 1,634 - - L80 (psi) T95 E Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Casing Dimensions and Minimum Performance Properties (psi) (psi) (psi) (psi) (kips) Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 5,990 8,280 8,240 9,100 9,190 1,945 - - - - - - R95 6,150 8,740 8,700 9,610 8,790 2,053 - - - - - - T95 6,150 8,740 8,700 9,610 9,710 2,053 - - - - - - T95 HC 7,690 8,740 8,700 9,610 9,710 2,053 - - - - - - T95 E 6,300 9,200 9,150 10,120 9,710 2,161 - - - - - - T95 HCE 7,690 9,200 9,150 10,120 9,710 2,161 - - - - - - - P110 6,540 10,120 10,070 11,130 11,630 2,377 - - - - - - - - P110 HCE 8,430 11,510 11,440 12,640 12,640 2,702 - - - - - - - - C110 6,540 10,120 10,070 11,130 10,700 2,377 - - - - - - - - - Q125 6,810 11,510 11,440 12,640 12,640 2,702 - - - - - - - - - - Q125 HC 8,630 11,510 11,440 12,640 12,640 2,702 - - - - - - (in) (lb/ft) (in) (in2) 11 3/4 75.00 73.54 0.618 21.613 10.358 N/A (psi) (psi) (psi) (psi) (psi) (kips) 4,880 6,930 6,900 7,640 7,430 1,634 - - - - - - Q125 HCE 8,630 12,430 12,360 13,660 13,190 2,918 - - - - - - L80 1Cr 4,880 6,930 6,900 7,640 7,430 1,634 - - - - - - J55 5,000 5,370 5,340 5,890 5,430 1,257 - - - - - - L80 HC 6,290 6,930 6,900 7,640 7,430 1,634 - - - - - - K55 5,000 5,370 5,340 5,890 6,870 1,257 - - - - - - L80 IRP 4,880 6,930 6,900 7,640 7,430 1,634 - - - - - - N80 6,430 7,820 7,770 8,560 7,330 1,829 - - - - - - L80 HCE 6,290 7,580 7,550 8,360 7,430 1,787 - - - - - - L80 6,430 7,820 7,770 8,560 8,410 1,829 - - - - - - C90 5,130 7,800 7,760 8,600 8,630 1,838 - - - - - - L80 1Cr 6,430 7,820 7,770 8,560 8,410 1,829 - - - - - - R95 5,240 8,230 8,200 9,070 8,260 1,940 - - - - - - L80 HC 7,780 7,820 7,770 8,560 8,410 1,829 - - - - - - T95 5,240 8,230 8,200 9,070 9,120 1,940 - - - - - - L80 IRP 6,430 7,820 7,770 8,560 8,410 1,829 - - - - - - T95 HC 6,760 8,230 8,200 9,070 9,120 1,940 - - - - - - L80 HCE 7,780 8,550 8,500 9,370 8,410 2,001 - - - - - - T95 E 5,330 8,670 8,630 9,550 9,120 2,042 - - - - - - C90 6,890 8,790 8,740 9,630 9,780 2,058 - - - - - - T95 HCE 6,760 8,670 8,630 9,550 9,120 2,042 - - - - - - R95 7,110 9,280 9,230 10,170 9,350 2,172 - - - - - - P110 5,470 9,530 9,490 10,510 10,920 2,246 - - - - - - T95 7,110 9,280 9,230 10,170 10,330 2,172 - - - - - - P110 HCE 7,250 10,840 10,780 11,940 11,870 2,552 - - - - - - T95 HC 8,620 9,280 9,230 10,170 10,330 2,172 - - - - - - C110 5,470 9,530 9,490 10,510 10,050 2,246 - - - - - - T95 E 7,310 9,770 9,710 10,710 10,330 2,286 - - - - - - Q125 5,760 10,840 10,780 11,940 11,870 2,552 - - - - - - T95 HCE 8,620 9,770 9,710 10,710 10,330 2,286 - - - - - - Q125 HC 7,370 10,840 10,780 11,940 11,870 2,552 - - - - - - P110 7,670 10,750 10,680 11,780 12,380 2,515 - - - - - - Q125 HCE 7,370 11,700 11,650 12,900 12,390 2,757 - - - - - - P110 HCE 9,690 12,210 12,140 13,380 13,450 2,858 - - - - - - J55 4,470 5,060 5,040 5,560 5,100 1,189 - - - - - - C110 7,670 10,750 10,680 11,780 11,390 2,515 - - - - - - K55 4,470 5,060 5,040 5,560 6,460 1,189 - - - - - - Q125 8,120 12,210 12,140 13,380 13,450 2,858 - - - - - - N80 5,630 7,360 7,320 8,090 6,890 1,729 - - - - - - Q125 HC 9,990 12,210 12,140 13,380 13,450 2,858 - - - - - - L80 11 3/4 79.00 77.80 0.656 22.863 10.282 N/A 5,630 7,360 7,320 8,090 7,900 1,729 - - - - - - Q125 HCE 9,990 13,190 13,110 14,450 14,040 3,087 - - - - - - L80 1Cr 5,630 7,360 7,320 8,090 7,900 1,729 - - - - - - J55 3,880 4,720 4,700 5,200 4,740 1,136 - - - - - - L80 HC 7,040 7,360 7,320 8,090 7,900 1,729 - - - - - - K55 3,880 4,720 4,700 5,200 6,010 1,136 - - - - - - L80 IRP 5,630 7,360 7,320 8,090 7,900 1,729 - - - - - - N80 4,750 6,860 6,830 7,570 6,400 1,652 - - - - - - L80 HCE 7,040 8,050 8,010 8,850 7,900 1,891 - - - - - - L80 4,750 6,860 6,830 7,570 7,340 1,652 - - - - - - 11 7/8 71.80 70.26 0.582 20.648 10.555 10.625 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Vallourec USA Corporation / Performance Data 11 3/4” - 26” / pg. 85 pg. 84 Vallourec USA Corporation / Performance Data 11 3/4” - 26” Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Casing Dimensions and Minimum Performance Properties Pipe Body Drift API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) L80 1Cr 4,750 6,860 6,830 7,570 7,340 1,652 L80 HC 13 3/8 61.00 59.50 0.430 17.487 12.359 N/A 13 3/8 68.00 66.17 0.480 19.445 12.259 N/A Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength OD 8rd LC Weight Wall Area Pipe Body Drift BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) - - - - - - T&C (in) PE (lb/ft) (in) (in2) API ALT. (in) (in) Grade PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 2,330 7,850 7,830 8,760 8,500 2,431 5,220 1,458 - - 4,930 2,306 Q125 HC 2,930 7,850 7,830 8,760 8,500 2,431 5,220 1,458 - - 4,930 2,306 (psi) Q125 13 3/8 68.00 66.17 0.480 19.445 12.259 N/A Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (kips) 6,160 6,860 6,830 7,570 7,340 1,652 - - - - - - L80 IRP 4,750 6,860 6,830 7,570 7,340 1,652 - - - - - - Q125 HCE 2,930 8,480 8,460 9,460 8,870 2,625 5,220 1,563 - - 4,930 2,444 L80 HCE 6,160 7,500 7,470 8,270 7,340 1,807 - - - - - - N80 2,670 5,380 5,360 5,990 4,990 1,661 4,550 1,040 - - 4,930 1,693 C90 4,980 7,720 7,680 8,510 8,540 1,858 - - - - - - L80 2,670 5,380 5,360 5,990 5,710 1,661 4,550 1,029 - - 4,930 1,650 R95 5,080 8,150 8,110 8,980 8,170 1,962 - - - - - - L80 1Cr 2,670 5,380 5,360 5,990 5,710 1,661 4,550 1,029 - - 4,930 1,650 T95 5,080 8,150 8,110 8,980 9,020 1,962 - - - - - - L80 HC 3,410 5,380 5,360 5,990 5,710 1,661 4,550 1,029 - - 4,930 1,650 6,590 8,150 8,110 8,980 9,020 1,962 - - - - - - L80 IRP 2,670 5,380 5,360 5,990 5,710 1,661 4,550 1,029 - - 4,930 1,650 5,170 8,580 8,540 9,460 9,020 2,065 - - - - - - L80 HCE 3,410 5,880 5,870 6,550 5,710 1,817 4,550 1,105 - - 4,930 1,729 T95 HCE 6,590 8,580 8,540 9,460 9,020 2,065 - - - - - - C90 2,780 6,050 6,040 6,740 6,630 1,869 4,550 1,142 - - 4,930 1,797 P110 5,290 9,430 9,390 10,400 10,800 2,271 - - - - - - R95 2,830 6,390 6,370 7,110 6,350 1,973 4,550 1,204 - - 4,930 1,893 P110 HCE 7,190 10,720 10,670 11,820 11,740 2,581 - - - - - - 13 3/8 72.00 70.67 0.514 20.768 12.191 12.250 T95 2,830 6,390 6,370 7,110 7,010 1,973 4,550 1,204 - - 4,930 1,893 C110 5,290 9,430 9,390 10,400 9,940 2,271 - - - - - - T95 HC 3,490 6,390 6,370 7,110 7,010 1,973 4,550 1,204 - - 4,930 1,893 Q125 5,630 10,720 10,670 11,820 11,740 2,581 - - - - - - T95 E 2,850 6,730 6,710 7,490 7,010 2,077 4,550 1,254 - - 4,930 1,945 Q125 HC 7,400 10,720 10,670 11,820 11,740 2,581 - - - - - - T95 HCE 3,490 6,730 6,710 7,490 7,010 2,077 4,550 1,254 - - 4,930 1,945 Q125 HCE 7,400 11,580 11,520 12,770 12,250 2,788 - - - P110 11 7/8 71.80 70.26 0.582 20.648 10.555 10.625 T95 HC T95 E 13 3/8 54.50 52.79 0.380 15.513 12.459 N/A 8rd SC - - - 2,880 7,400 7,380 8,240 8,390 2,284 5,220 1,401 - - 4,930 2,221 J55 1,130 2,730 2,730 3,070 2,710 853 2,730 514 - - 2,730 909 P110 HCE 3,560 8,410 8,380 9,360 9,120 2,596 5,220 1,576 - - 4,930 2,463 K55 1,130 2,730 2,730 3,070 3,440 853 2,730 547 - - 2,730 1,038 Q125 2,880 8,410 8,380 9,360 9,120 2,596 5,220 1,576 - - 4,930 2,463 J55 1,540 3,090 3,090 3,460 3,080 962 3,090 595 - - 3,090 1,025 Q125 HC 3,580 8,410 8,380 9,360 9,120 2,596 5,220 1,576 - - 4,930 2,463 K55 1,540 3,090 3,090 3,460 3,900 962 3,090 633 - - 3,090 1,170 Q125 HCE 3,580 9,080 9,050 10,110 9,520 2,804 5,220 1,688 - - 4,930 2,611 J55 1,950 3,450 3,450 3,850 3,440 1,069 3,450 675 - - 3,450 1,140 N80 3,100 5,760 5,740 6,390 5,340 1,773 - - - - - - K55 1,950 3,450 3,450 3,850 4,360 1,069 3,450 718 - - 3,450 1,300 L80 3,100 5,760 5,740 6,390 6,120 1,773 - - - - - - N80 2,260 5,020 5,010 5,610 4,650 1,556 4,550 963 - - 4,930 1,585 L80 1Cr 3,100 5,760 5,740 6,390 6,120 1,773 - - - - - - L80 2,260 5,020 5,010 5,610 5,320 1,556 4,550 952 - - 4,930 1,545 L80 HC 4,090 5,760 5,740 6,390 6,120 1,773 - - - - - - L80 1Cr 2,260 5,020 5,010 5,610 5,320 1,556 4,550 952 - - 4,930 1,545 L80 IRP 3,100 5,760 5,740 6,390 6,120 1,773 - - - - - - L80 HC 2,820 5,020 5,010 5,610 5,320 1,556 4,550 952 - - 4,930 1,545 L80 HCE 4,090 6,300 6,280 6,990 6,120 1,939 - - - - - - L80 IRP 2,260 5,020 5,010 5,610 5,320 1,556 4,550 952 - - 4,930 1,545 C90 3,270 6,480 6,460 7,190 7,110 1,994 - - - - - - L80 HCE 2,820 5,500 5,480 6,130 5,320 1,701 4,550 1,023 - - 4,930 1,618 R95 3,350 6,840 6,810 7,590 6,810 2,105 - - - - - - C90 2,320 5,650 5,640 6,310 6,180 1,750 4,550 1,057 - - 4,930 1,683 T95 3,350 6,840 6,810 7,590 7,520 2,105 - - - - - - R95 2,340 5,970 5,950 6,660 5,920 1,847 4,550 1,114 - - 4,930 1,772 T95 HC 4,210 6,840 6,810 7,590 7,520 2,105 - - - - - - T95 2,340 5,970 5,950 6,660 6,530 1,847 4,550 1,114 - - 4,930 1,772 T95 E 3,400 7,200 7,170 7,990 7,520 2,216 - - - - - - T95 HC 2,870 5,970 5,950 6,660 6,530 1,847 4,550 1,114 - - 4,930 1,772 T95 HCE 4,210 7,200 7,170 7,990 7,520 2,216 - - - - - - T95 E 2,330 6,280 6,260 7,010 6,530 1,945 4,550 1,161 - - 4,930 1,821 P110 3,490 7,920 7,890 8,790 9,000 2,438 - - - - - - T95 HCE 2,870 6,280 6,260 7,010 6,530 1,945 4,550 1,161 - - 4,930 1,821 P110 HCE 4,330 9,000 8,970 9,990 9,780 2,770 - - - - - - P110 2,330 6,910 6,890 7,710 7,820 2,139 5,220 1,297 - - 4,930 2,079 Q125 3,550 9,000 8,970 9,990 9,780 2,770 - - - - - - P110 HCE 2,910 7,850 7,830 8,760 8,500 2,431 5,220 1,458 - - 4,930 2,306 Q125 HC 4,370 9,000 8,970 9,990 9,780 2,770 - - - - - - 13 3/8 77.00 75.40 0.550 22.160 12.119 N/A Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength pg. 86 Vallourec USA Corporation / Performance Data 11 3/4” - 26” Vallourec USA Corporation / Performance Data 11 3/4” - 26” / pg. 87 Casing Dimensions and Minimum Performance Properties OD Weight T&C Wall Area PE Casing Dimensions and Minimum Performance Properties Pipe Body Drift API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC T&C PE API ALT. (in) (in) Grade IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 13 3/8 77.00 75.40 0.550 22.160 12.119 N/A Q125 HCE 4,370 9,710 9,680 10,790 10,210 2,992 - - - - - - N80 3,980 6,420 6,400 7,100 5,980 2,042 - - - - - - L80 3,980 6,420 6,400 7,100 6,860 2,042 - - - - - - L80 1Cr 3,980 6,420 6,400 7,100 6,860 2,042 - - - - - - L80 HC 5,340 6,420 6,400 7,100 6,860 2,042 - - - - - - L80 IRP 3,980 6,420 6,400 7,100 6,860 2,042 - - - - - - C110 L80 HCE 5,340 7,020 7,000 7,770 6,860 2,233 - - - - - - Q125 C90 4,130 7,220 7,200 7,990 7,970 2,297 - - - - - R95 4,260 7,630 7,600 8,430 7,630 2,425 - - - - - T95 4,260 7,630 7,600 8,430 8,420 2,425 - - - - T95 HC 5,620 7,630 7,600 8,430 8,420 2,425 - - - T95 E (in) (lb/ft) (in) (in2) 13 5/8 88.20 86.86 0.625 25.525 12.219 12.250 14 14 14 82.50 80.73 0.562 23.726 12.689 N/A 94.80 93.58 0.656 27.500 12.501 N/A 99.30 97.91 0.688 28.773 12.437 N/A Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength (psi) (psi) (psi) (psi) (psi) (kips) Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 4,780 6,880 6,850 7,580 7,370 2,302 - - - - - - L80 HC 6,200 6,880 6,850 7,580 7,370 2,302 - - - - - - R95 5,120 8,170 8,130 9,010 8,190 2,733 - - - - - - P110 5,330 9,460 9,420 10,430 10,830 3,165 - - - - - - P110 HC 7,100 9,460 9,420 10,430 10,830 3,165 - - - - - - 5,330 9,460 9,420 10,430 9,970 3,165 - - - - - - 5,660 10,750 10,700 11,850 11,770 3,597 - - - - - - - Q125 HC 7,220 10,750 10,700 11,850 11,770 3,597 - - - - - - - N80 5,340 7,200 7,160 7,920 6,730 2,403 - - - - - - - - L80 5,340 7,200 7,160 7,920 7,720 2,403 - - - - - - - - - L80 HC 6,760 7,200 7,160 7,920 7,720 2,403 - - - - - - R95 5,800 8,550 8,510 9,410 8,590 2,854 - - - - - - P110 6,130 9,900 9,850 10,890 11,360 3,304 - - - - - - (in) 14 (lb/ft) (in) (in2) 99.30 97.91 0.688 28.773 12.437 N/A (psi) L80 (psi) (psi) (psi) (psi) (kips) 4,370 8,030 7,990 8,880 8,420 2,553 - - - - - - T95 HCE 5,620 8,030 7,990 8,880 8,420 2,553 - - - - - - P110 4,570 8,830 8,790 9,760 10,080 2,808 - - - - - - P110 HC 7,980 9,900 9,850 10,890 11,360 3,304 - - - - - - P110 HCE 5,950 10,030 9,990 11,100 10,960 3,191 - - - - - - C110 6,130 9,900 9,850 10,890 10,450 3,304 - - - - - - C110 4,570 8,830 8,790 9,760 9,280 2,808 - - - - - - Q125 6,330 11,250 11,190 12,380 12,340 3,755 - - - - - - Q125 4,800 10,030 9,990 11,100 10,960 3,191 - - - - - - Q125 HC 8,140 11,250 11,190 12,380 12,340 3,755 - - - - - - Q125 HC 5,970 10,030 9,990 11,100 10,960 3,191 - - - - - - N80 6,260 7,720 7,670 8,460 7,230 2,567 - - - - - - Q125 HCE 5,970 10,840 10,790 11,980 11,430 3,446 - - - - - - L80 6,260 7,720 7,670 8,460 8,300 2,567 - - - - - - K55 2,420 3,860 3,850 4,290 4,890 1,305 - - - - - - L80 HC 7,630 7,720 7,670 8,460 8,300 2,567 - - - - - - N80 2,940 5,620 5,600 6,250 5,210 1,898 - - - - - - R95 6,900 9,170 9,110 10,050 9,230 3,048 - - - - - - L80 2,940 5,620 5,600 6,250 5,970 1,898 - - - - - - P110 7,430 10,620 10,550 11,640 12,220 3,529 - - - - - - L80 HC 3,840 5,620 5,600 6,250 5,970 1,898 - - - - - - P110 HC 9,430 10,620 10,550 11,640 12,220 3,529 - - - - - - R95 3,160 6,670 6,650 7,420 6,640 2,254 - - - - - - C110 7,430 10,620 10,550 11,640 11,240 3,529 - - - - - - K55 3,530 4,510 4,490 4,980 5,740 1,513 - - - - - - Q125 7,840 12,060 11,990 13,230 13,280 4,010 - - - - - - N80 4,220 6,560 6,530 7,250 6,110 2,200 - - - - - - Q125 HC 9,700 12,060 11,990 13,230 13,280 4,010 - - - - - - L80 4,220 6,560 6,530 7,250 7,010 2,200 - - - - - - N80 6,750 8,000 7,950 8,760 7,500 2,654 - - - - - - L80 HC 5,600 6,560 6,530 7,250 7,010 2,200 - - - - - - L80 6,750 8,000 7,950 8,760 8,620 2,654 - - - - - - R95 4,450 7,790 7,760 8,610 7,800 2,613 - - - - - - L80 HC 8,070 8,000 7,950 8,760 8,620 2,654 - - - - - - P110 4,800 9,020 8,980 9,960 10,310 3,025 - - - - - - R95 7,500 9,500 9,440 10,400 9,580 3,152 - - - - - - P110 HC 4,800 9,020 8,980 9,960 10,310 3,025 - - - - - - 114.00 112.89 0.800 33.175 12.213 12.250 P110 8,130 11,000 10,930 12,040 12,680 3,649 - - - - - - C110 4,800 9,020 8,980 9,960 9,490 3,025 - - - - - - P110 HC 10,200 11,000 10,930 12,040 12,680 3,649 - - - - - - Q125 5,060 10,250 10,210 11,320 11,200 3,438 - - - - - - C110 8,130 11,000 10,930 12,040 11,670 3,649 - - - - - - Q125 HC 6,330 10,250 10,210 11,320 11,200 3,438 - - - - - - Q125 8,650 12,500 12,420 13,680 13,780 4,147 - - - - - - - - - - - - Q125 HC 10,540 12,500 12,420 13,680 13,780 4,147 - - - - - - - - - - - - K55 N80 3,900 4,730 4,710 5,210 6,020 1,583 4,780 6,880 6,850 7,580 6,420 2,302 - - - - - - 14 14 14 14 103.50 102.21 0.720 30.039 12.373 N/A 110.00 109.17 0.772 32.082 12.269 N/A 115.00 114.48 0.812 33.642 12.189 12.250 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N80 6,960 8,120 8,070 8,880 7,620 2,691 pg. 88 / Vallourec USA Corporation / Performance Data 11 3/4” - 26” Vallourec USA Corporation / Performance Data 11 3/4” - 26” / pg. 89 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE Pipe Body Drift API ALT. (in) (in) Grade 14 14 16 16 16 Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC T&C PE API ALT. (in) (in) Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) PBYS 8rd SC 8rd LC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 6,960 8,120 8,070 8,880 8,750 2,691 - - - - - - R95 L80 HC 8,100 8,880 8,820 9,710 8,750 2,944 - - - - - - T95 7,750 9,640 9,580 10,540 9,730 3,196 - - - - - - 115.00 114.48 0.812 33.642 12.189 12.250 P110 8,430 11,170 11,090 12,210 12,880 3,701 P110 HC 10,250 12,690 12,600 13,870 13,920 4,205 - - - - - - - - - - - - C110 8,430 11,170 11,090 12,210 11,850 3,701 - - - - - - C110 Q125 8,990 12,690 12,600 13,870 14,000 4,205 - - - - - - Q125 Q125 HC 10,560 13,700 13,610 14,980 14,430 4,542 - - - - - - Q125 HC 1,880 6,770 6,760 7,580 7,300 3,014 3,230 1,773 N80 7,100 8,200 8,150 8,960 7,700 2,716 - - - - - - K55 1,860 3,380 3,370 3,770 4,270 1,499 - - L80 7,100 8,200 8,150 8,960 8,840 2,716 - - - - - - N80 2,140 4,920 4,910 5,490 4,550 2,181 - - L80 HC 8,120 8,200 8,150 8,960 8,840 2,716 - - - - - - L80 2,140 4,920 4,910 5,490 5,210 2,181 - R95 7,920 9,740 9,670 10,640 9,830 3,226 - - - - - - L80 HC 2,650 4,920 4,910 5,490 5,210 2,181 116.00 115.53 0.820 33.953 12.173 12.250 P110 8,630 11,280 11,200 12,320 13,020 3,735 - - - - - - 2,180 5,530 5,520 6,180 6,050 2,453 P110 HC 10,350 11,280 11,200 12,320 13,020 3,735 - - - - - - C110 8,630 11,280 11,200 12,320 11,980 3,735 - - - - - - Q125 (lb/ft) (in) (in2) (psi) 14 Casing Dimensions and Minimum Performance Properties 120.00 119.49 0.850 35.115 12.113 N/A 65.00 62.64 0.375 18.408 15.063 N/A 75.00 72.86 0.438 21.414 14.937 N/A 84.00 82.05 0.495 24.112 14.823 N/A Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength L80 R95 (psi) (psi) (psi) (psi) (kips) (in) 16 16 (lb/ft) (in) (in2) 84.00 82.05 0.495 24.112 14.823 N/A 94.50 92.75 0.562 27.257 14.689 N/A BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) 1,480 5,140 5,130 5,760 5,080 2,291 3,230 1,354 - - 3,550 2,153 1,480 5,140 5,130 5,760 5,610 2,291 3,230 1,354 - - 3,550 2,153 T95 HC 1,860 5,140 5,130 5,760 5,610 2,291 3,230 1,354 - - 3,550 2,153 P110 1,480 5,960 5,940 6,670 6,720 2,652 3,230 1,575 - - 3,550 2,518 P110 HC 1,860 5,960 5,940 6,670 6,720 2,652 3,230 1,575 - - 3,550 2,518 1,480 5,960 5,940 6,670 6,180 2,652 3,230 1,552 - - 3,550 2,444 1,480 6,770 6,760 7,580 7,300 3,014 3,230 1,773 - - 3,550 2,809 - - 3,550 2,809 - - - - - - - - - - - - - - - - - - - - - - - - - C90 HC 2,660 5,530 5,520 6,180 6,050 2,453 - - - - - - R95 2,190 5,840 5,830 6,520 5,790 2,589 - - - - - - T95 (psi) C90 (psi) (psi) (psi) (psi) (kips) 9,230 12,810 12,730 14,000 14,150 4,244 - - - - - - 2,190 5,840 5,830 6,520 6,390 2,589 - - - - - - Q125 HC 10,580 12,810 12,730 14,000 14,150 4,244 - - - - - - T95 HC 2,690 5,840 5,830 6,520 6,390 2,589 - - - - - - N80 7,630 8,500 8,440 9,270 7,990 2,809 - - - - - - P110 2,190 6,760 6,750 7,550 7,650 2,998 - - - - - - L80 7,630 8,500 8,440 9,270 9,180 2,809 - - - - - - P110 HC 2,730 6,760 6,750 7,550 7,650 2,998 - - - - - - L80 HC 8,160 8,500 8,440 9,270 9,180 2,809 - - - - - - C110 2,190 6,760 6,750 7,550 7,040 2,998 - - - - - - R95 8,560 10,090 10,020 11,010 10,210 3,336 - - - - - - Q125 2,190 7,680 7,670 8,580 8,310 3,407 - - - - - - P110 9,380 11,690 11,600 12,750 13,520 3,863 - - - - - - Q125 HC 2,740 7,680 7,670 8,580 8,310 3,407 - - - - - - P110 HC 10,400 11,690 11,600 12,750 13,520 3,863 - - - - - - K55 1,950 3,460 3,450 3,860 4,370 1,533 - - - - - - C110 9,380 11,690 11,600 12,750 12,440 3,863 - - - - - - N80 2,270 5,030 5,020 5,610 4,660 2,229 - - - - - - Q125 10,090 13,280 13,190 14,490 14,690 4,389 - - - - - - L80 2,270 5,030 5,020 5,610 5,330 2,229 - - - - - - Q125 HC 10,600 13,280 13,190 14,490 14,690 4,389 - - - - - - L80 HC 2,650 5,030 5,020 5,610 5,330 2,229 - - - - - - J55 630 2,260 2,250 2,550 2,230 1,012 2,260 591 - - 2,260 1,031 K55 J55 2,330 5,660 5,650 6,310 6,190 2,508 - - - - - - 630 2,260 2,250 2,550 2,830 1,012 2,260 625 - - 2,260 1,144 C90 HC 2,660 5,660 5,650 6,310 6,190 2,508 - - - - - - 1,010 2,630 2,630 2,960 2,610 1,178 2,630 710 - - 2,630 1,200 R95 2,350 5,970 5,960 6,670 5,930 2,647 - - - - - - K55 1,010 2,630 2,630 2,960 3,310 1,178 2,630 752 - - 2,630 1,331 T95 2,350 5,970 5,960 6,670 6,540 2,647 - - - - - - K55 1,400 2,980 2,970 3,340 3,750 1,326 2,980 865 - - 2,980 1,499 T95 HC 2,690 5,970 5,960 6,670 6,540 2,647 - - - - - - N80 1,480 4,330 4,320 4,850 3,990 1,929 3,230 1,167 - - 3,550 1,898 P110 2,340 6,920 6,900 7,720 7,830 3,065 - - - - - - L80 1,480 4,330 4,320 4,850 4,570 1,929 3,230 1,156 - - 3,550 1,861 P110 HC 2,730 6,920 6,900 7,720 7,830 3,065 - - - - - - L80 HC 1,840 4,330 4,320 4,850 4,570 1,929 3,230 1,156 - - 3,550 1,861 C110 2,340 6,920 6,900 7,720 7,210 3,065 - - - - - - 1,480 4,870 4,860 5,460 5,310 2,170 3,230 1,284 - - 3,550 2,043 Q125 2,340 7,860 7,840 8,770 8,510 3,483 - - - - - - C90 HC 1,850 4,870 4,860 5,460 5,310 2,170 3,230 1,284 - - 3,550 2,043 Q125 HC 2,740 7,860 7,840 8,770 8,510 3,483 - - - - - - C90 16 97.00 94.81 0.575 27.864 14.663 N/A Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength C90 pg. 90 Vallourec USA Corporation / Performance Data 11 3/4” - 26” Vallourec USA Corporation / Performance Data 11 3/4” - 26” / pg. 91 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) Grade 16 16 109.00 107.60 0.656 31.622 14.501 N/A 118.00 116.83 0.715 34.334 14.383 N/A 128.00 127.06 0.781 37.341 14.251 N/A Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength N80 L80 Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) 16 Casing Dimensions and Minimum Performance Properties (psi) (psi) (psi) (psi) PBYS (kips) 3,080 5,740 5,720 6,370 5,330 2,530 8rd SC OD 8rd LC Weight Wall Area Pipe Body Drift BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) - - - - - - T&C (in) 16 PE (lb/ft) (in) (in2) API ALT. (in) (in) 128.00 127.06 0.781 37.341 14.251 N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) C110 5,240 9,400 9,350 10,360 9,900 4,108 - - - - - - Q125 5,570 10,680 10,630 11,780 11,690 4,668 - - - - - - 3,080 5,740 5,720 6,370 6,110 2,530 - - - - - - L80 HC 4,060 5,740 5,720 6,370 6,110 2,530 - - - - - - Q125 HC 7,090 10,680 10,630 11,780 11,690 4,668 - - - - - - 3,250 6,460 6,440 7,170 7,090 2,846 - - - - - - N80 5,760 7,440 7,400 8,170 6,960 3,236 - - - - - - C90 HC 4,080 6,460 6,440 7,170 7,090 2,846 C90 - - - - - - L80 5,760 7,440 7,400 8,170 7,990 3,236 - - - - - - R95 3,320 6,820 6,790 7,570 6,790 3,004 - - - - - - L80 HC 7,170 7,440 7,400 8,170 7,990 3,236 - - - - - - T95 3,320 6,820 6,790 7,570 7,490 3,004 - - - - - - 6,130 8,370 8,320 9,190 9,290 3,641 - - - - - - T95 HC 4,180 6,820 6,790 7,570 7,490 3,004 - - - - - - C90 HC 7,300 8,370 8,320 9,190 9,290 3,641 - - - - - - P110 3,470 7,890 7,870 8,770 8,980 3,478 - - - - - - R95 6,300 8,830 8,780 9,700 8,880 3,843 - - - - - - P110 HC 4,300 7,890 7,870 8,770 8,980 3,478 - - - - - - T95 6,300 8,830 8,780 9,700 9,810 3,843 - - - - - - C110 3,470 7,890 7,870 8,770 8,260 3,478 - - - - - - T95 HC 7,840 8,830 8,780 9,700 9,810 3,843 - - - - - - Q125 16 138.00 137.66 0.850 40.456 14.113 N/A C90 3,520 8,970 8,940 9,960 9,750 3,953 - - - - - - P110 6,730 10,230 10,170 11,230 11,750 4,450 - - - - - - Q125 HC 4,330 8,970 8,940 9,960 9,750 3,953 - - - - - - P110 HC 8,640 10,230 10,170 11,230 11,750 4,450 - - - - - - N80 3,690 6,260 6,230 6,930 5,820 2,747 - - - - - - C110 6,730 10,230 10,170 11,230 10,810 4,450 - - - - - - L80 3,690 6,260 6,230 6,930 6,670 2,747 - - - - - - Q125 7,020 11,620 11,560 12,770 12,770 5,057 - - - - - - L80 HC 5,030 6,260 6,230 6,930 6,670 2,747 - - - - - - Q125 HC 8,850 11,620 11,560 12,770 12,770 5,057 - - - - - - 3,920 7,040 7,010 7,790 7,760 3,090 - - - - - - N80 6,620 7,930 7,880 8,680 7,430 3,437 - - - - - - C90 HC 5,150 7,040 7,010 7,790 7,760 3,090 - - - - - - L80 6,620 7,930 7,880 8,680 8,540 3,437 - - - - - - R95 4,030 7,430 7,400 8,220 7,420 3,262 - - - - - - L80 HC 7,960 7,930 7,880 8,680 8,540 3,437 - - - - - - T95 C90 4,030 7,430 7,400 8,220 8,190 3,262 - - - - - - 7,110 8,920 8,860 9,770 9,930 3,867 - - - - - - T95 HC 5,260 7,430 7,400 8,220 8,190 3,262 - - - - - - C90 HC 8,010 8,920 8,860 9,770 9,930 3,867 - - - - - - P110 4,300 8,600 8,570 9,520 9,810 3,777 - - - - - - R95 7,340 9,410 9,360 10,310 9,490 4,081 - - - - - - T95 7,340 9,410 9,360 10,310 10,490 4,081 - - - - - - 16 147.00 146.19 0.906 42.962 14.001 N/A C90 P110 HC 5,490 8,600 8,570 9,520 9,810 3,777 - - - - - - C110 4,300 8,600 8,570 9,520 9,030 3,777 - - - - - - T95 HC 8,850 9,410 9,360 10,310 10,490 4,081 - - - - - - Q125 4,490 9,780 9,740 10,820 10,660 4,292 - - - - - - P110 7,950 10,900 10,830 11,940 12,560 4,726 - - - - - - Q125 HC 5,540 9,780 9,740 10,820 10,660 4,292 - - - - - - P110 HC 10,000 10,900 10,830 11,940 12,560 4,726 - - - - - - N80 4,700 6,830 6,800 7,540 6,380 2,987 - - - - - - C110 7,950 10,900 10,830 11,940 11,560 4,726 - - - - - - L80 4,700 6,830 6,800 7,540 7,310 2,987 - - - - - - Q125 8,440 12,390 12,310 13,560 13,650 5,370 - - - - - - L80 HC 6,110 6,830 6,800 7,540 7,310 2,987 - - - - - - Q125 HC 10,330 12,390 12,310 13,560 13,650 5,370 - - - - - - 4,930 7,690 7,650 8,480 8,500 3,361 - - - - - - K55 630 2,250 2,250 2,540 2,820 1,367 - - - - - - C90 HC 6,230 7,690 7,650 8,480 8,500 3,361 - - - - - - N80 630 3,270 3,270 3,690 3,000 1,989 - - - - - - R95 5,020 8,120 8,080 8,950 8,130 3,547 - - - - - - L80 T95 5,020 8,120 8,080 8,950 8,980 3,547 - - - - - - T95 HC 6,530 8,120 8,080 8,950 8,980 3,547 - - - - - P110 5,240 9,400 9,350 10,360 10,760 4,108 - - - - P110 HC 6,980 9,400 9,350 10,360 10,760 4,108 - - - - C90 630 3,270 3,270 3,690 3,430 1,989 - - - - - - L80 HC 630 3,270 3,270 3,690 3,430 1,989 - - - - - - - R95 630 3,880 3,880 4,380 3,820 2,362 - - - - - - - - P110 630 4,500 4,490 5,070 5,040 2,734 - - - - - - - - P110 HC 630 4,500 4,490 5,070 5,040 2,734 - - - - - - 18 5/8 87.50 84.59 0.435 24.858 17.568 N/A Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength pg. 92 / Vallourec USA Corporation / Performance Data 11 3/4” - 26” Vallourec USA Corporation / Performance Data 11 3/4” - 26” / pg. 93 Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) Grade K55 N80 L80 18 5/8 96.50 94.05 0.485 27.639 17.468 17.500 L80 HC Pipe Body Drift IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) - - - - - - T&C (in) 20 PE (lb/ft) (in) (in2) API ALT. (in) (in) 118.50 116.98 0.563 34.379 18.687 N/A Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) L80 HC 1,110 3,940 3,930 4,430 4,150 2,750 - - - - - - R95 1,110 4,680 4,670 5,260 4,620 3,266 - - - - - - - - - - - - 870 3,650 3,640 4,100 3,350 2,211 - - - - - - 870 3,650 3,640 4,100 3,830 2,211 - - - - - - P110 1,110 5,420 5,410 6,090 6,100 3,782 - - - - - K55 1,490 3,060 3,050 3,420 3,850 2,125 2,400 1,253 2,410 1,453 2,310 2,123 - - - - - - N80 1,600 4,450 4,440 4,980 4,100 3,091 2,400 1,707 2,410 1,973 2,310 2,877 P110 870 5,010 5,010 5,640 5,630 3,040 - - - - - - L80 1,600 4,450 4,440 4,980 4,700 3,091 2,400 1,692 2,410 1,955 2,310 2,849 P110 HC 870 5,010 5,010 5,640 5,630 3,040 - - - - - - 20 133.00 131.45 0.635 38.631 18.543 N/A L80 HC 1,600 4,450 4,440 4,980 4,700 3,091 2,400 1,692 2,410 1,955 2,310 2,849 K55 1,420 2,990 2,990 3,350 3,770 1,805 - - - - - - R95 1,600 5,280 5,270 5,910 5,220 3,670 2,400 1,985 2,410 2,293 2,310 3,340 N80 1,500 4,350 4,340 4,880 4,010 2,626 - - - - - - P110 1,600 6,110 6,100 6,840 6,900 4,249 2,400 2,309 2,410 2,667 2,310 3,887 L80 1,500 4,350 4,340 4,880 4,590 2,626 - - - - - - K55 1,900 3,410 3,400 3,810 4,310 2,363 - - - - - - L80 HC 1,500 4,350 4,340 4,880 4,590 2,626 - - - - - - N80 2,190 4,960 4,950 5,540 4,590 3,437 - - - - - - R95 1,500 5,170 5,160 5,790 5,110 3,118 - - - - - - L80 P110 1,500 5,980 5,970 6,710 6,750 3,611 - - - - - - P110 HC 1,500 5,980 5,970 6,710 6,750 3,611 - - - - - K55 2,090 3,580 3,570 3,990 4,530 2,147 - - - - N80 2,480 5,210 5,200 5,810 4,820 3,123 - - - L80 2,480 5,210 5,200 5,810 5,530 3,123 - - - 2,480 5,210 5,200 5,810 5,530 3,123 - - R95 2,590 6,190 6,170 6,890 6,140 3,709 - P110 2,190 4,960 4,950 5,540 5,260 3,437 - - - - - - L80 HC 2,190 4,960 4,950 5,540 5,260 3,437 - - - - - - - R95 2,250 5,890 5,880 6,580 5,850 4,082 - - - - - - - - P110 2,250 6,820 6,810 7,620 7,720 4,727 - - - - - - - - - K55 2,500 3,910 3,900 4,340 4,950 2,692 - - - - - - - - - N80 3,020 5,680 5,670 6,310 5,270 3,916 - - - - - - - - - - L80 3,020 5,680 5,670 6,310 6,040 3,916 - - - - - - - - - - - L80 HC 3,020 5,680 5,670 6,310 6,040 3,916 - - - - - - 20 20 147.00 146.21 0.709 42.969 18.395 N/A 169.00 166.56 0.812 48.948 18.189 N/A 2,610 7,160 7,140 7,980 8,120 4,294 - - - - - - R95 3,250 6,750 6,730 7,500 6,720 4,650 - - - - - - P110 HC 2,610 7,160 7,140 7,980 8,120 4,294 - - - - - - P110 3,370 7,820 7,790 8,680 8,890 5,384 - - - - - - K55 2,250 3,720 3,710 4,140 4,710 2,228 - - - - - - N80 2,710 5,410 5,400 6,020 5,020 3,240 - - - - - - 2,710 5,410 5,400 6,020 5,750 3,240 - - - - - - 2,710 5,410 5,400 6,020 5,750 3,240 - - - - - - R95 2,870 6,430 6,410 7,150 6,390 3,848 - - - - - - P110 2,930 7,440 7,420 8,280 8,450 4,455 - - - - - - P110 HC 2,930 7,440 7,420 8,280 8,450 4,455 - - - - - 24 162.00 158.61 0.635 46.611 22.543 N/A 174.00 171.45 0.688 50.387 22.437 N/A K55 920 2,550 2,540 2,870 3,200 2,564 - - - - - - N80 920 3,700 3,700 4,170 3,410 3,729 - - - - - - K55 1,160 2,760 2,750 3,100 3,470 2,771 - - - - - - N80 1,170 4,010 4,010 4,510 3,700 4,031 - - - - - - L80 1,170 4,010 4,010 4,510 4,230 4,031 - - - - - - R95 1,170 4,770 4,760 5,350 4,700 4,787- - - - - - P110 1,170 5,520 5,510 6,200 6,210 5,543 - - - - - - K55 520 2,110 2,110 2,380 2,640 1,480 2,110 824 2,110 955 2,110 1,479 K55 1,440 3,010 3,000 3,370 3,790 3,013 - - - - - - K55 770 2,410 2,400 2,710 3,020 1,685 2,400 960 2,410 1,113 2,310 1,683 N80 1,530 4,380 4,370 4,900 4,040 4,383 - - - - - - N80 770 3,500 3,500 3,940 3,220 2,450 2,400 1,307 2,410 1,511 2,310 2,281 L80 1,530 4,380 4,370 4,900 4,620 4,383 - - - - - - L80 770 3,500 3,500 3,940 3,680 2,450 2,400 1,296 2,410 1,497 2,310 2,259 R95 1,530 5,200 5,190 5,820 5,140 5,204 - - - - - - 770 3,500 3,500 3,940 3,680 2,450 2,400 1,296 2,410 1,497 2,310 2,259 P110 1,530 6,020 6,000 6,740 6,780 6,026 - - - - - - K55 1,180 2,780 2,770 3,120 3,490 3,272 - - - - - - N80 1,190 4,040 4,030 4,530 3,720 4,760 - - - - - - L80 1,190 4,040 4,030 4,530 4,260 4,760 - - - - - - K55 1,100 2,710 2,710 3,040 3,400 1,891 - - 24 Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength 2,510 2,500 2,820 3,150 1,520 Area - L80 HC 118.50 116.98 0.563 34.379 18.687 N/A (kips) Wall 4,330 4,320 4,870 4,260 2,626 20 (psi) Weight BC 3,650 3,640 4,100 3,830 2,211 L80 18 5/8 139.00 137.81 0.720 40.500 16.998 17.000 L80 HC 106.50 104.23 0.500 30.631 18.813 N/A (psi) OD 8rd LC 870 20 (psi) 8rd SC 870 18 5/8 136.00 132.84 0.693 39.040 17.052 N/A L80 HC 94.00 91.59 0.438 26.918 18.937 N/A 870 (psi) PBYS R95 18 5/8 114.00 111.70 0.579 32.825 17.280 N/A Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) 20 Casing Dimensions and Minimum Performance Properties - - - - 24 189.00 186.41 0.750 54.782 22.313 N/A - N80 1,110 3,940 3,930 4,430 3,630 2,750 - - - - - - L80 1,110 3,940 3,930 4,430 4,150 2,750 - - - - - - 26 207.00 202.44 0.750 59.494 24.313 N/A Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength pg. 94 / Vallourec USA Corporation / Performance Data 11 3/4” - 26” Marking & Color Codes Casing Dimensions and Minimum Performance Properties OD Weight T&C (in) Wall Area PE (lb/ft) (in) (in2) Pipe Body Drift API ALT. (in) (in) 26 207.00 202.44 0.750 59.494 24.313 N/A 26 223.00 218.64 0.812 64.254 24.189 N/A Abbreviated Terms SC short round thread casing LC long round thread casing BC buttress thread casing ALT. alternative drift IP internal pressure PBYS pipe body yield strength Grade Connections Collapse IP IP IP IP Pressure (Barlow) (Lame’- (Lame’- (Lame’open) capped) ductile rupture) (psi) (psi) (psi) (psi) (psi) PBYS (kips) 8rd SC 8rd LC BC IP Jt. Strength IP Jt. Strength IP Jt. Strength (psi) (kips) (psi) (kips) (psi) (kips) R95 1,190 4,800 4,790 5,380 4,730 5,652 - - - - - - K55 1,440 3,010 3,000 3,370 3,780 3,534 - - - - - - N80 1,520 4,370 4,360 4,900 4,030 5,140 - - - - - - R95 1,520 5,190 5,180 5,820 5,130 6,104 - - - - - - Marking & Color Codes pg. 95 / Vallourec USA Corporation / Marking Marking Example 1: 9-5/8” 53.50# Q125 DWC/C Vallourec Star 5CT-XXXX SF X/XX 9-5/8 53.50 Q1 XXF S S2L2 PXXXXX DWC/C DA 8.500 JtXXX XX W/O XXXXXX SLN XXXXXX Made in USA XX.X XXXX Heat Traceability end finish API monogram manufacturer license number OD size date of manufacture grade nominal wt/ft (last digit of year/ month) reduced alternative impact test temperature if applicable seamless process of manufacture test pressure special drift type of thread supplementary requirements if applicable serialization compatible standards (EC, HC, HCE, RY, E, MS) work order number weight heat number country of origin length Casing Thread-Type Identification Symbols Short Round Thread SC Long Round Thread LC Buttress Thread BC * Special clearance couplings shall also have a black band. * * Seal-ring couplings shall also have a blue band. Example 2: 9-5/8” 53.50# P110MS VAM TOP Vallourec Star 5CT-XXXX July 2014 license number SF X/XX end finish API monogram manufacturer 9-5/8 53.50 OD size date of manufacture P XXF S S2L2 PXXXXX VAM TOP DA 8.500 JtXXX grade nominal wt/ft (last digit of year/ month) reduced alternative impact test temperature if applicable seamless process of manufacture test pressure MS W/O XXXXXX special drift type of thread supplementary requirements if applicable serialization compatible standards (EC, HC, HCE, RY, E, MS) SLN XXXXXX Made in USA work order number XX.X XXXX weight heat number country of origin length Example 3: 5-1/2” 23.00# P110EC VAM SG Vallourec Star 5CT-XXXX API monogram manufacturer license number Vallourec's SLN (Schedule Line Number) is assigned at the time of rolling to provide heat identification and traceability throughout the entire process. SF X/XX end finish date of manufacture (last digit of year/ month) 5-1/2 23.00 OD size P XXF S [ ] PXXXXX VAM SG grade nominal wt/ft reduced alternative impact test temperature if applicable seamless process of manufacture test pressure supplementary requirements if applicable D JtXXX EC W/O XXXXXX drift type of thread serialization compatible standards (EC, HC, HCE, RY, E, MS) SLN XXXXXX Made in USA work order number XX.X XXXX weight heat number country of origin length pg. 96 / Vallourec USA Corporation / Color Codes pg. 97 / Vallourec USA Corporation / Color Codes pg. 98 / Vallourec USA Corporation / Color Codes Color Codes Color Codes Color Codes Grade Coupling Pipe color code color for threaded and/or code plain end pipes Coupling Entire Pipe Band 1 Band 2 Band 3 Band 4 Band 1 Band 2 Band 3 Band 4 Band 5 API Grades - API 9th Edition Grade Coupling Pipe color code color for threaded and/or code plain end pipes Coupling Entire Pipe Band 1 Band 2 Band 3 Band 4 Band 1 Band 2 Band 3 Band 4 Band 5 Grade Coupling Pipe color code color for threaded and/or code plain end pipes Coupling Entire Pipe Band 1 Band 2 Band 3 Band 4 Band 1 Band 2 Band 3 Band 4 Band 5 Vallourec High Collapse Grades Vallourec API Enhanced Grades J55 tubing Green Green VMS 55 HC Red Green Green Green Black VM 80 HC Red J55 casing Green White Green L80 Type 1 HC Red Brown Red Brown Black VM 95 HC Brown Green Brown Green K55 Green Green Green L80 Type 1 HCE Red Brown Pink Red Brown Black VM 110 HC White Green White Green N80 Type 1 Red Red VM 80 ECL Red Brown Orange Orange Light blue Red Brown Orange Orange Light blue VM 125 HC Orange Green Orange Green N80 Q Red Red C90 HC Purple Purple Black VM 125 HYHC Orange Orange Purple Green R95 Brown Brown T95 E Silver Pink Pink Silver Pink VM 140 HC Pink White Green Pink White Green L80 Type 1 Red Brown Red Brown T95 HC Silver Silver Black VM 150 HC Dark green White Green Dark green White Green Yellow Yellow Red Brown Yellow Yellow T95 HCE Silver Pink Pink Silver Black Pink Yellow Red Brown Yellow P110 MS White Dark green Dark green Orange White Dark green Dark green No entire L80 9CR color painting No entire L80 13CR color painting Green (N80 Q coupling) Green Pink Pink Pink (Q125 coupling) Pink Green Green Red Green Green Pink Vallourec Sour Service & High Collapse Grades Orange VM 80 HCSS Red Brown Green Orange Orange Red Brown Green Orange Orange C90 Purple Purple P110 RY White Dark green Dark green White Dark green Dark green VM 90 HCSS Purple Green Orange Orange Purple Green Orange Orange T95 Silver Silver P110 EC White Light blue Light blue White Light blue Light blue VM 95 HCSS Silver Green Orange Orange Silver C110 White Brown Brown White Brown Brown P110 HCE White Pink Pink White Black Pink VM 110 HCSS White Brown Brown Green P110 White White Q125 HC Orange Orange Black VM 125 HCSS Orange Green Q125 Orange Orange Q125 HCE Orange Pink Orange Black Pink Pink Pink Pink Silver Green Orange Orange Orange White Brown Brown Green Orange Silver Orange Green Silver Silver pg. 99 / Vallourec USA Corporation / Color Codes Color Codes Grade Coupling Pipe color code color for threaded and/or code plain end pipes Coupling Entire Pipe Band 1 Band 2 Band 3 Band 4 Band 1 Band 2 Band 3 Band 4 Band 5 Vallourec Sour Service Grades VM 80 SS Red VM 90 SS Purple Orange Orange Purple Orange Orange VM 95 SS Silver Orange Orange Silver Orange Orange VM 100 SS Blue Blue Orange Orange VM 110 SS White Brown Brown Orange White Brown Brown Orange VM 125 SS Orange Silver Orange Silver Silver VM 80 IRP Red VM 90 IRP Purple Brown Orange Orange Purple Brown Orange Orange VM 95 IRP Silver Brown Orange Orange Silver VM 140 CY Orange Orange Purple VM 125 CY Orange Brown Purple Orange Brown Purple VM 130 CY Orange Yellow Purple Orange Yellow Purple VM 140 CY Orange Purple Orange Purple (T95) (T95) Brown Orange Orange Orange Orange Silver Red Brown Brown Orange Orange Red Brown Orange Orange Brown Brown Orange Orange Brown Orange Orange Vallourec HY / CY Grades (Q125 coupling) VM125HY-VM140CY pg. 100 / Vallourec USA Corporation / Color Codes Color Codes Grade Coupling Pipe color code color for threaded and/or code plain end pipes Coupling Entire Pipe Band 1 Band 2 Band 3 Band 4 Band 1 Band 2 Band 3 Band 4 Band 5 Vallourec Deep Well Grades VM 140 Pink White Pink White VM 150 Dark green White Dark green White Vallourec Risers Grades VM 95 R Brown Blue Blue Brown Blue Blue VM 95 RSS Silver Blue Blue Silver Blue Blue VM 110 R White Blue Blue White Blue Blue VM 110 RSS White Brown Brown Blue VM 125 R Orange Blue (R95) (T95) Brown Blue Blue Brown White Brown Brown Blue Orange Blue Blue Vallourec 13%Cr Grades VM 80 13CR Red Yellow Orange Red Brown Yellow Orange VM 85 13CR Blue Yellow Blue Yellow VM 90 13CR Purple Yellow Purple Yellow VM 95 13CR Brown Yellow Brown Yellow VM 95 13CRSS Yellow White Green Silver White Green Silver VM 110 13CRSS Yellow White Green White White Green White VM 125 13CRSS Yellow White Green Orange White Green Orange VM 110 Yellow White Green White Vallourec Super 13%Cr Grades 13ECRSSCY Purple White Green White Purple Blue Leader in Premium Tubular Solutions Europe North America South America July 2014 Africa Sales Offices Steel Plants USA Ph +1 713.479.3200 info.vus-na@vallourec.com Manufacturing Plants Asia and Middle East Accessories and Repair VAM® Licensee Facilities Canada Ph +1 403.233.0119 sales.vca-can@vallourec.com VAM® Field Service International Mexico Ph +52.229.989.8716 contacto.octg-mex@vallourec.com www.vallourec.com