P16 Sales Gresen
Transcription
P16 Sales Gresen
Series P16 Series Description Page P16 - Standard Pump ........................181 - 184 FEATURES: • Available in various configurations TP16-2 - Tandem, 2 Place ............185 - 188 • Cast iron pumping sections for durability TP16-3 - Tandem, 3 Place ............189 - 192 PVP16 - Priority Valve Gear ..........193 - 197 • Aluminum flanges and covers for optimum power to weight ratio. • Journal bearings for long life and good over-hung load capability • Buna-N Seals are standards for petroleum and glycol based fluids “Viton” seals are optional. • Pressure balanced plates for greater efficiency. Series 20 CP16 - Clutch Option ......................199 - 202 DP16 - Dump Pump Option ............203 - 206 Series Description GRESEN® SERIES Gear Pumps & Motors ® Page 20 - Standard Pump ............................207 - 209 FEATURES: • Available in various configurations • Construction: Aluminum - For excellent power to weight ratio or Cast iron - for extra durability. • Journal bearings for long life and good over-hung load capability • Buna-N Seals are standards for petroleum and glycol based fluids “Viton” seals are optional. • Pressure balanced plates for greater efficiency. NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 R20 - Reversible Pump......................211 - 214 M20 - Motor ......................................215 - 217 TP20-2 - Tandem, 2 Place ............219 - 221 TP20-3 - Tandem, 3 Place ............223 - 226 NST20 - Flow Sensitive ..................227 - 230 NSD20 - Flow Sensitive..................231 - 234 NDS20 - Pressure Summation ......235 - 238 SPM20 - Two-Speed ......................239 - 241 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 157 GRESEN® SERIES 158 Gear Pumps & Motors Pump and Motor Displacement Chart UNIT SIZE P1-10 P1-15 P1-20 P1-25 (2)P1-30 DISPLACEMENT U.S. GPR CIR LPR .000886 .2047 .00335 .001330 .3072 .00503 .001773 .4096 .00671 .002216 .5119 .00838 .002955 .6826 .01119 1200 1.06 1.60 2.13 2.70 3.55 1800 1.59 2.39 3.19 3.99 5.32 DISPLACEMENT IN GPM AT SPEEDS INDICATED 1900 2000 2100 2200 2300 2400 1.68 1.77 1.86 1.95 2.04 2.13 2.53 2.66 2.79 2.93 3.06 3.19 3.37 3.55 3.72 3.90 4.08 4.25 4.21 4.43 4.65 4.87 5.10 5.32 5.61 5.91 6.21 6.50 6.80 7.09 2500 2.21 3.32 4.43 5.54 7.39 P12-17 P12-22 P12-28 P12-34 P12-40 P12-45 .0014 .0019 .0024 .0030 .0034 .0039 .333 .433 .554 .683 .794 .905 .0055 .0073 .0091 .0112 .0130 .0148 1000 1.40 1.90 2.40 3.00 3.40 3.90 1200 1.68 2.28 2.88 3.60 4.08 4.68 1800 2.52 3.42 4.32 5.40 6.12 7.02 2000 2.80 3.80 4.80 6.00 6.80 7.80 2200 3.08 4.18 5.28 6.60 7.48 8.58 2400 3.36 4.56 5.76 7.20 8.16 9.36 2600 3.64 4.94 6.24 7.80 8.84 10.14 2800 3.92 5.32 6.72 8.40 9.52 10.92 3000 4.20 5.70 7.20 9.00 10.20 11.70 P14-42 P14-59 P14-74 P14-91 P14-108 .0035 .0049 .0062 .0076 .0090 .808 1.132 1.432 1.756 2.079 .0132 .0185 .0235 .0288 .0341 3.50 4.90 6.20 7.60 9.00 4.20 5.88 7.44 9.12 10.80 6.30 8.82 11.16 13.68 16.20 7.00 9.80 12.40 15.20 18.00 7.70 10.78 13.64 16.72 19.80 8.40 11.76 14.88 18.24 21.60 9.10 12.74 16.12 19.76 23.40 9.80 13.72 17.36 21.28 25.20 10.50 14.70 18.60 22.80 27.00 P2-45 P2-65 P2-85 P2-95 (2)P2-105 P2-115 P2-150 P2-200 .00397 .00561 .00728 .00817 .00872 .0100 .01328 .0169 .918 1.296 1.681 1.887 2.014 2.31 3.090 3.904 .01503 .02123 .02755 .03092 .03301 .03785 .05026 .06396 1200 4.76 6.73 8.73 9.80 10.46 12.00 15.70 20.30 1800 7.15 10.10 13.10 14.70 15.70 18.00 23.60 30.40 1900 7.55 10.67 13.82 15.50 16.57 19.00 24.90 32.10 2000 7.95 11.22 14.57 16.34 17.44 20.00 26.20 33.80 2100 8.34 11.79 15.29 17.13 18.31 21.00 17.60 35.50 2200 8.74 12.35 16.00 17.95 19.18 22.00 28.80 37.20 2300 9.14 12.91 16.75 18.75 20.06 23.00 30.20 38.90 2400 9.54 13.47 17.48 19.60 20.93 24.00 31.50 40.50 2500 9.94 14.02 18.20 20.40 21.80 25.00 32.80 42.20 P16-45 P16-65 P16-85 P16-100 P16-115 P16-150 P16-180 P16-200 P16-250 .0038 .0055 .0072 .0085 .0097 .0127 .0152 .0169 .0211 .878 1.270 1.663 1.964 2.241 2.934 3.511 3.902 4.874 .0144 .0208 .0273 .0321 .0367 .0481 .0575 .0639 .0798 1000 3.80 5.55 7.20 8.50 9.70 12.70 15.20 16.69 21.10 1200 4.56 6.66 8.64 10.20 11.64 15.24 18.24 20.28 25.32 1800 6.84 9.90 12.96 15.30 17.46 22.86 27.36 30.42 37.98 2000 7.60 11.00 14.40 17.00 19.40 25.40 30.40 33.80 42.20 2200 8.36 12.10 15.84 18.70 21.34 27.94 33.44 37.18 46.42 2400 9.12 13.20 17.28 20.40 23.28 30.48 36.48 40.56 50.64 2600 9.88 14.30 18.72 22.10 25.22 33.02 (4) (4) (4) 2800 10.64 15.40 20.16 23.80 27.16 35.56 (4) (4) (4) 3000 11.40 16.50 21.60 25.50 29.10 (3) (4) (4) (4) P6-060 P6-080 P6-100 P6-120 P6-150 .0052 .0070 .0087 .0105 .0131 1.201 1.617 2.010 2.426 3.026 .01968 .02650 .03293 .03974 .04958 1200 6.24 8.40 10.49 12.60 15.72 1800 9.36 12.60 15.65 18.90 23.58 1900 9.88 13.30 16.53 19.95 24.89 2000 10.40 14.00 17.40 21.00 26.20 2100 10.92 14.70 18.27 22.05 27.51 2200 11.44 15.40 19.14 23.10 28.82 2300 11.96 16.10 20.01 24.15 30.13 2400 12.48 16.80 20.88 25.20 31.44 2500 13.00 17.50 21.75 26.25 32.75 PM23-13 PM23-16 PM23-19 PM23-22 PM23-25 PM23-28 PM23-31 .0109 .0137 .0164 .0192 .0219 .0247 .0274 2.518 3.165 3.788 4.435 5.059 5.706 6.329 .0413 .0519 .0621 .0727 .0829 .0935 .1037 1000 10.90 13.70 16.40 19.20 21.90 24.70 27.40 1200 13.08 16.44 19.68 23.04 26.28 29.64 32.88 1400 15.26 19.18 22.96 26.88 30.66 34.58 38.36 1600 17.44 21.92 26.24 30.72 35.04 39.52 43.84 1800 19.62 24.66 29.52 34.56 39.42 44.46 49.32 2000 21.80 27.40 32.80 38.40 43.80 49.40 54.80 2200 23.98 30.14 36.08 42.24 48.18 54.34 60.28 2400 26.16 32.88 39.36 46.08 52.56 59.28 65.76 2500 27.25 34.25 41.00 48.00 54.75 61.75 68.50 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 GRESEN® INFORMATION Gear Pumps & Motors GENERAL PRODUCT AND SAFETY INFORMATION INTENDED USE OF THESE PRODUCTS ! WARNING WARNING: The Pumps and motors in this catalog are designed for, and intended for use, only on mobile equipment hydraulic systems. Use of these pumps and motors or other applications will void the warranty, as such use may also result in damage to the pump and motor, or to other equipment in the system. In some cases, use for unapproved applications could result in serious bodily injury from an equipment failure. In order to avoid property damage or bodily injury, do not use these pumps and motors for other applications. CONSIDERATIONS FOR MAXIMUM PRODUCT LIFE AND PERFORMANCE Things to be considered include, but are not limited to: ■ fluid type and cleanliness. ■ system flow and pressure requirements (including pressure spikes) ■ adequate port and plumbing sizes. ■ reservoir size and location. ■ operating temperature. ■ integrated system valving. ■ duty cycle. ■ operating speeds. HYDRAULIC OIL REQUIREMENTS To obtain maximum life of gresen pumps and motors, the hydraulic fluid must meet or exceed the specifications shown on page 142. ! CAUTION CAUTION: Failure to use fluids that meet these specifications can shorten the life of the pump and/or motor, and result in failure. A failure due to the use of improper fluids, may in some instances result in damage to other items in the hydraulic circuit. Such failures will not be covered by warranty. Clean oil is important and we recommend at least a minimal 10 micron return filter, properly sized for the system and maintained on a regular service schedule to a minimum ISO cleanliness level of 17/14. Gresen pumps and motors work well on most fire resistant fluids, but because some of these fluids require special seals, these applications should be approved in advance by Gresen Pump Engineering. ! WARNING ! WARNING WARNING: Improperly installed or maintained pumps and motors, and their connections, could result in external leakage, which may cause property damage or serious bodily injury. In order to avoid such damage or injury, you should carefully follow all installation and maintenance instructions which accompany the product. WARNING: When using those items that may require tapping into the vehicle air brake system (e.g., pneumatic controls for “air cylinders” on Dry Valve Pumps or “air shifters” on Dump Pumps) a “Pressure Protection Valve” (our part number 16393) or the equivalent) should be used. In the event of a failure in the air cylinder, air shifter, or their control lines, a Pressure Protection Valve will prevent the loss of air from the vehicle brake circuit. Loss of air from the vehicle brake circuit could cause loss of control of the vehicle, which could result in serious injury or death. BUILDERS AND REBUILDERS ! CAUTION CAUTION: For those who are authorized to build and rebuild Gresen gear pumps and motors, the tolerances on new parts require that a pump or motor be assembled and “run-in” according to a specific procedure. This should be done on a test stand with proper filtration rather than on the application, as the run-in procedure will generate metallic particles, which if not caught, may cause damage throughout the system. If there are any questions or clarifications required, please contact: Hercules Hydraulics Component Division Phone Toll Free in the U.S. at 1-800-333-5617 160 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 Assembly Torque Values Overhung Load Data NOTES: A All torque values are based on a lubricated condition. If capscrews and/or nuts are dirty, they must be washed, blown dry, and re-oiled prior to installation. Al studs must be washed and blown dry–DO NOT re-oil. The following torque values are to be used in the assembly of pumps and motors: SERIES SIZE P1 P12 P14, FP14, TFP14 SSFP14 P2 P16, HP16 FPR16 FP16 TFP16 SSFP16 DP16 DP16 (valve) FP17 20, M20, FP20 P6, FM6, TM6 25, M25, FP25 FP257, FPW257 HP7, HM7, FP7 SL7 HP8, HM8, FP8, SL8 PM23 DPH HILLSDALE HILLSDALE T101/102 MGG/PGG (body) MGG/PGG (flange) 5/16" TORQUE (FT.-LBS.) 20-25 20-25 30-35 80-90 30-35 70-75 80-90 160-175 160-175 160-175 70-75 30-35 18-20 80-90 80-90 160-175 160-175 240-250 160-175 240-250 180-190 180-190 40-45 50-55 195-200 21-24 46-54 (in.-lb.) M10 3/8" 1/2" 3/8" 1/2" 1/2" 5/8" 5/8" 5/8" 1/2" 3/8" 5/16" 1/2" 1/2" 5/8" 5/8" 3/4" 5/8" 3/4" 5/8" 5/8" 3/8" 7/16" 5/8" 5/16" #10 NOTES: For “Mixed” Series, ie: TP25450-20200-P14-45A, use torque values corresponding to each section: 25 Series for the 25450 (160175), 20 Series for the 20200 (80-90), and P14 Series for the P14-45 (30-35). Verify stud/capscrew sizes. Torque value should be divided into two or three equal values, and applied in stages. e.g. P16 should be first torqued to 35 ft. lbs. then torqued to the final value of 70-75 ft. lbs. While torquing the pump please follow pattern as shown below: 1 Dim. “A” 1.00" ” ” ” ” ” 1.00" ” ” ” ” 1.00" ” ” ” ” ” ” ” 1.50" ” ” ” ” ” ” 1.50" ” ” ” ” 1.50" 1.50" Allowable Load “L” 100 Lbs.. ” ” ” ” ” 200 Lbs.. ” ” ” ” 390 Lbs.. ” ” ” ” ” ” ” 1050 Lbs.. ” ” ” ” ” ” 1050 Lbs.. ” ” ” ” 1300 Lbs.. 1300 Lbs.. Allowable Operating Pressure 2000 PSI ” ” ” ” ” 2000 PSI ” ” ” ” 2200 PSI 2200 PSI 2100 PSI 2100 PSI 2000 PSI 1800 PSI 1700 PSI 1600 PSI 2000 PSI ” ” ” ” ” ” 1800 PSI 1600 PSI 1350 PSI 1150 PSI 900 PSI 3000 PSI 2800 PSI Allowable Load “L” must not be exceeded. 5 8 3 1 4 7 3 6 PUMP SIZE P12-17 -22 -28 -34 -40 -45 P14-42 -59 -74 -91 -108 P16-45 -65 -85 -100 -115 -150 -180 -200 20150 20200 20250 20300 20350 20400 20450 25500 25550 25600 25770 25950 HP7 HP8 GRESEN® SERIES Gear Pumps & Motors ® 4 2 When Belt Drive is used, “L” must include both belt pre-tension and torque load. 2 NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 161 ntertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial ntertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial ntertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories Cylinders / Prince Cylinders & Pumps / Chief Cylinders / ® Description. . . . . . . . . . . . . . . . . . . . . Gear Pumps Flow Range . . . . . . . . . . . . . . . . . . . . TO 38 GPM Displacements . . . . . . . . . . . . . . . TO 3.904 C.I.R. GRESEN® - P16 Series P16 Maximum Pressure to . . . . . . . . . . . . . . . 3000 PSI Maximum Speed to. . . . . . . . . . . . . . . . 3600 RPM Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . A or C Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . Journal Series P16 Construction . . . . . . . . . . Cast Iron Gear Plate with Aluminum Flange and Cover Plate Performance Data DISPLACEMENT/REVOLUTION (Theoretical) PUMP SIZES MAXIMUM PRESSURE MAXIMUM SPEED US Gallons Cubic Inches Liters Cubic Centimeters Imperial Gallons PSI BAR RPM P16 - 45 .0038 .878 .0144 14.388 .0031 3000 207 3600 P16 - 65 .0055 1.270 .0208 20.812 .0045 3000 207 3600 P16 - 85 .0072 1.663 .0273 27.252 .0059 3000 207 3400 P16 - 100 .0085 1.964 .0321 32.184 .0070 3000 207 3300 P16 - 115 .0097 2.241 .0367 36.723 .0080 3000 207 3100 P16 - 150 .0127 2.934 .0481 48.080 .0105 3000 207 2800 P16 - 180 .0152 3.511 .0575 57.535 .0126 2200 152 2500 P16 - 200 .0169 3.902 .0639 63.942 .0140 2000 138 2200 All data based on SAE 10W oil at 150˚F. Available with Viton Seals for use with phosphate ester base fluids. How To Order ‘A’ denotes counterclockwise rotation ‘C’ denotes clockwise rotation When viewed from drive shaft end Rotation Pump Size Shaft Flange Cover Plate Series P16-115A - 2N3 Note: Add prefix ‘V’ to pump model number (VP16-) when ordering pumps with Viton Seals for use with phosphate ester base fluids. NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 181 GRESEN® - P16 Series P16 Shafts Available 1 5/8" Dia. 9 Tooth Spline Flat Root Side Fit 2 Torque Limit 52 Lbs. Ft. Major Dia. .75 .72 7/8" Dia. 13 Tooth Spline Flat Root Side Fit Torque Limit 184 Lbs. Ft. Full Spine .608 .603 Major Dia. Flg. Mtg. Surface 1.25-'D' 1.12-'F' 1.32-'N' 1.56 1.44 1.69 1.64 Flanges Torque Limit 184 Lbs. Ft. Spline Data Diametral Pitch . . . . . . . 16/32 Pressure Angle . . . . . . . . . 30° No. Of Teeth . . . . . . . . . . . . . 9 Minor Dia. . . . . . . . . .472-.483 Diametral Pitch . . . . . . . 16/32 Pressure Angle . . . . . . . . . 30° No. Of Teeth . . . . . . . . . . . . 13 Minor Dia. . . . . . . . . .722-.733 6 Torque Limit 184 Lbs. Ft. 1/4" x 1/4" x 1-1/2" Lg. Key .875 .874 .982 Flange Mtg. Surface 1.19 Full 1.16 Spline 7/8" Straight Shaft 7/8" Straight Shaft for Piggy-Back 'D' Flange 'F' Flange 'J' 'E' & 'G' Flanges 'N' Flange .8585 .8535 Spline Data 5 3 .06 1.19 .25 3/4" Straight Shaft 9 Torque Limit 105 Lbs. Ft. Flg Mtg Surface 'N' Flange 1.89 7/8" Tapered Shaft Torque Limit 184 Lbs. Ft. 1/4" x 1/4" x 1-3/4" Lg. Key 5/32" x 5/8" Woodruff Key .982 .875 .874 .25 .849 .829 3/16" x 3/16" x 1-1/4" Lg. Key Dia. .832 .749.Dia. .748 .06 1.50 Flange Mounting Surface 2.38 'D' Flange 2.25 'F' Flange 2.50 'J' & 'E .846 .836 1.62 1.81 'F' Flange 1.94 'D' Flange 2.01 'N' Flange Flanges 2.45 'N' Flange Gage Line .6328 .6298 .875 .873 7°8' Flange Mounting Surface Flange Mounting Surface 2.30 Flanges Available D SAE ‘A’ 2-Bolt 1.43 R F 7/16" Wide Mounting Slots Pad Mount 1.43 R 1.65 1.65 3.250 Pilot 3.248 Dia. 2.00 1/2-13NC Depth 1.00 2 Places 2.094 1.88 R 4.188 5.12 .875 1.750 Mounting Surface .62 1.13 For Gresen® Repair Parts See Pages 493 - 505 182 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 GRESEN® - P16 Series P16 Flanges Available N SAE ‘B’ 2-Bolt S P.T.O. Direct Mount Available with No. 2 Shaft Only 2.626 Typ 2.622 9/16" Dia. 2 Holes 1.43 R .125 1.65 4.000 Pilot 3.998 Dia. 2.875 .328 Dia. 2.38 R 1.312 CL PTO Pilot 5.750 6.88 T 2.750 Pilot 2.748 Dia. .191 CL Shaft Mounting Surface P.T.O. Direct Mount T19C Trans Available with No. 2 Shaft Only 2.626 2.622 Typ Suction Side .125 2.750 Pilot 2.748 Dia. .328 Dia. 1.312 .191 2.06 CL Shaft CL PTO Pilot .200 Mounting Surface Cover Plates Available 1 Rear Ported Straight Thread 2.75 2.62 2 Rear Ported NPT 7 Rear Ported BSPT Side Ported SAE 4-Bolt 3 2.75 .875 1.188 .43 .59 7/16-14NC Depth .88 2.62 3/8-16NC Depth .88 1.38 1.38 4 Side Ported NPT 8 Side Ported BSPT 1" NPT Suction SAE 16 (1-5/16-12UN-2B) Discharge 5 3/4" NPT 9 1" NPT 1.38 3/4" NPT Discharge Side Ported Straight Thread SAE 12 Discharge Side Ported Straight Thread SAE 16 Discharge SAE 12 (1-1/16-12UN-2B) Discharge Side 1.38 Di 1.15 1-1/4" SAE 4-Bolt Conn. Discharge Side Suction Side SAE 4-Bolt NPT Connectors Are Available. See Accessory Section 6 Rear Ported Straight Thread 2.75 2.62 SAE 16 SAE 20* (1-5/16-12UN-2B) (1-5/8-12UN-2B) SAE 16 (1-5/16-12U N-2B) Suction Suction Side Discharge Side 2.313 5 .62 Dia. * SAE 20 (1-5/8-12N-2B) Suction 1.2 .93 a. 3/4" SAE 4-Bolt Conn. 1.875 Discharge Side 1.38 1.38 SAE 12 (1-1/16-12UN-2B) Discharge Suction Side 5 *Suction Port Adaptor Fitting to Reduce SAE 20 to SAE 16 (1 /16–12UN–2B) Order Kit 15369 NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 183 GRESEN® - P16 Series P16 Dimensional Data Mounting Dimensions FLANGE TYPE PUMP SIZES D A P16 - 45 P16 - 65 P16 - 85 P16 - 100 P16 - 115 P16 - 150 P16 - 180 P16 - 200 IN 3.54 3.75 3.97 4.13 4.29 4.66 4.98 5.19 E B MM 89.9 95.3 100.9 104.9 108.9 118.4 126.5 131.8 IN 4.55 4.77 4.98 5.14 5.30 5.67 5.99 6.20 MM 115.6 121.2 126.5 130.6 134.6 144.1 152.2 157.5 A IN 4.66 4.88 5.09 5.25 5.41 5.78 6.10 6.31 B MM 118.4 123.6 129.3 133.3 137.4 146.8 154.9 160.3 SHIPPING WEIGHTS (Approx.) F IN 5.67 5.89 6.10 6.26 6.42 6.79 7.11 7.32 A MM 144.1 149.6 154.9 159.0 163.1 172.5 180.6 185.9 IN 3.66 3.88 4.09 4.25 4.41 4.78 5.10 5.31 B MM 92.9 98.6 103.6 107.9 112.0 121.4 129.5 134.9 IN 4.67 4.89 5.10 5.26 5.42 5.79 6.11 6.32 MM 118.6 124.2 129.5 133.6 137.7 147.1 155.2 160.5 lbs. 12 13 14 15 16 17 19 20 kgs. 5.5 5.9 6.4 6.8 7.3 7.7 8.6 9.1 Mounting Dimensions FLANGE TYPE PUMP SIZES G&J A P16 - 45 P16 - 65 P16 - 85 P16 - 100 P16 - 115 P16 - 150 P16 - 180 P16 - 200 IN 4.66 4.88 5.09 5.25 5.41 5.78 6.10 6.31 N B MM 118.4 123.6 129.3 133.3 137.4 146.8 154.9 160.3 IN 5.67 5.89 6.10 6.26 6.42 6.79 7.11 7.32 MM 144.1 149.6 154.9 159.0 163.1 172.5 180.6 185.9 A IN 3.47 3.69 3.90 4.06 4.22 4.59 4.91 5.12 B MM 88.1 93.7 99.1 103.1 107.2 116.6 124.7 130.1 Shaft Location For 'A' Rotation IN 4.48 4.70 4.91 5.07 5.23 5.60 5.92 6.13 A MM 113.8 119.4 124.7 128.8 132.8 142.2 150.4 155.7 IN 5.22 5.44 5.65 5.81 5.97 6.34 6.66 6.87 B MM 132.6 138.2 143.5 147.6 151.6 161.0 169.2 174.5 IN 6.23 6.45 6.66 6.82 6.98 7.35 7.67 7.88 MM 158.2 163.8 169.2 173.2 177.3 186.7 194.8 200.1 .82 5.35 4.12 .82 * .45 A lbs. 12 13 14 15 16 17 19 20 2.62 C Dimensions * C SHIPPING WEIGHTS (Approx.) S&T FLANGE TYPE IN MM D E F G J N S T .250 .187 — .250 .250 .375 .200 .200 6.35 4.74 — 6.35 6.35 9.52 5.08 5.08 kgs. 5.5 5.9 6.4 6.8 7.3 7.7 8.6 9.1 2.75 1.85 R 1.65 B ±.060 Mtg. Surface 184 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 *These dimensions locate SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com CL of bolt pattern only. NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 Description . . . . . . . . . . . Gear Pumps (Two-place) Flow Range . . . . . . . . . . . To 32 GPM Per Section Displacements . . . . . . . . . . . . . . . . To 3.904 C.I.R. Maximum Pressure to . . . . . . . . . . . . . . . 3000 PSI Maximum Speed to. . . . . . . . . . . . . . . . 3100 RPM Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . A or C Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . Journal Series TP16 Construction . . . . . . . . . Cast Iron Gear Plates with Aluminum Flange, Connector and Cover Plates GRESEN® - P16 - 2 PLACE Series TP16 - 2 Place Performance Data DISPLACEMENT/REVOLUTION (Theoretical) PUMP SIZES MAXIMUM PRESSURE MAXIMUM SPEED (RPM) US Gallons Cubic Inches Liters Cubic Centimeters Imperial Gallons PSI BAR Single Tandem TP16 - 45 .0038 .878 .0144 14.388 .0031 3000 207 3600 3100 TP16 - 65 .0055 1.270 .0208 20.812 .0045 3000 207 3600 3000 TP16 - 85 .0072 1.663 .0273 27.252 .0059 3000 207 3400 2900 TP16 - 100 .0085 1.964 .0321 32.184 .0070 3000 207 3300 2800 TP16 - 115 .0097 2.241 .0367 36.723 .0080 3000 207 3100 2600 TP16 - 150 .0127 2.934 .0481 48.080 .0105 3000 207 2800 2400 TP16 - 180 .0152 3.511 .0575 57.535 .0126 2200 152 2500 2100 TP16 - 200 .0169 3.904 .0639 63.942 .0140 2000 138 2200 1900 Note: For best inlet conditions, place largest displacement section in the rear position and use both inlet ports. All data based on SAE 10W oil at 150˚F. Available with Viton Seals for use with phosphate ester base fluids. How To Order ‘A’ denotes counterclockwise rotation ‘C’ denotes clockwise rotation When viewed from drive shaft end Shaft Rotation Pump Size—Rear Section Pump Size—Front Section Flange Connector Plate Series Cover Plate Tandem Pump TP16 - 150 - 100A - 5N33 Note: Add prefix ‘V’ to pump model number (VTP16-) when ordering pumps with Viton Seals for use with phosphate ester base fluids. NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 185 GRESEN® - P16 - 2 PLACE Series TP16 - 2 Place Shafts Available 2 7/8" Dia. 13 Tooth Spline Flat Root Side Fit. 5 Torque Limit 184 Lbs. Ft. 7/8" Straight Shaft Torque Limit 184 Lbs. Ft. 1/4" x 1/4" x 1-3/4" Lg. Key Major Dia. 1.19 Full 1.16 Spline Flange Mtg. Surface 982 .8585 .8535 .875 .874 Dia. .06 1.44 1.56 1.69 'F' Flange 'D' Flange 1.64 'N' Flange .25 1.50 2.25 'F' Flange 2.38 'D' Flange 'E' 'J' Flanges Flange Mounting Surface 2.50 'J' & 'E Flanges 2.45 'N' Flange Spline Data Diametral Pitch . . . . . . . . . . . 16/32 Pressure Angle . . . . . . . . . . . . . 30° No. Of Teeth . . . . . . . . . . . . . . . . 13 Minor Dia. . . . . . . . . . . . . .722-.733 Mounting Flanges Available D SAE ‘A’ 2-Bolt Pad Mount F .44 (1,11) Wide Mounting Slots 1.65 (41,9) 1.65 (41,9) 3.250 (82,5) Pilot 3.248 (82,4) Dia. 2.09 (53,1) 2.00 (50,8) .87 (22,2) 1/2-13NC Depth 1.00 2 Places 1.88 R (47,7) 1.75 (44,4) Mounting Surface 4.18 (106,4) 1.13 (28,7) .62 (15,7) 5.12 (130,0) N SAE ‘B’ 2-Bolt S .56 (14,2) Dia. 2 Holes P.T.O. Direct Mount Available with No. 2 Shaft Only 2.626 2.622 Typ .125 1.65 (41,9) 4.000 (101,6) Pilot 3.998 (101,5) Dia. 2.750 Pilot 2.748 Dia. .328 Dia. 2.87 (123,0) 6.88 (174,7) 1.312 5.75 (146,0) CL PTO Pilot .191 CL Shaft .200 .187 Mounting Surface 3.31 For Gresen® Repair Parts See Pages 493 - 505 186 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 - 2 Place Discharge Ports for Connector Plate and Cover Plate 3 SAE 4-Bolt .875 (22,0) 3/8-16UNC Depth .81 (20,3) * .43 (10,9) 4 NPT-Pipe Thread 8 BSPT-Pipe Thread 5 SAE 12 Straight Thread SAE 16 Straight Thread 9 .62 Dia. (15,7) 1.87 (46,7) .93 * (23,3) 3/4" SAE 4-Bolt Conn. SAE 4-Bolt NPT Connectors Are Available. See Accessory Section 3/4-14 PT 1-1/16-12UN-2B 1-5/16-12UN-2B GRESEN® - P16 - 2 PLACE Series TP16 Dimensional Data PD Factors Flange Dimensions The maximum size and number of sections of a tandem pump for a given application is limited to the torque capability of the input drive shaft and the spline coupling between the sections. To determine this capability, a “PD Factor” is used: F IN MM IN MM D E F J N S .250 .187 — .250 .375 .200 6.35 4.75 — 6.35 9.52 5.08 1.62 2.75 1.75 2.75 1.55 3.31 41.15 69.85 44.45 69.85 38.10 84.07 Maximum allowable PD for the 7/8" drive shaft is 53. Maximum allowable PD for a coupling is also 53. When: E FLANGE TYPE P = PSI (The relief valve setting of each individual section). D = Displacement (In U.S. gallons per revolution of each individual section). Example: Assume a two-place pump TP16-150 — 150 with front and rear sections on pressure at the same time at 2000 PSI: A. Drive Shaft: PD = (2000) (.0127) + (2000) (.0127) = 50.8 vs. 53. Capability is OK B. Coupling between front and center sections: PD = (2000) (.0127) = 25.4 vs. 53. Capability is OK. .82 * (20,8) A C 1-1/2" SAE 4-Bolt Conn. Common Suction 2.6 (66,0) 1.85 R (46,9) 2.8 (71,1) 2.7 (68,5) Conn. Plate Cover Plate This Suction Port Always Closed with Plug or Plate Shaft Location for 'A' Rotation .70 (17,8) 1.406 (35,7) 1/2-13NC Depth .81 (20,5) 2.75 (69,8) .82 * (20,8) .82* (20,8) Mtg. Surface Drawn for Clockwise Rotation *These dimensions locate NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 E F 1.37 * (34,9) 1.62 Dia. (41,1) B D ±.060 4.12 (104,6) 5.35 (135,8) .75 (19,0) CL of bolt pattern only. SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 187 GRESEN® - P16 - 2 PLACE 188 Series TP16 - 2 Place Dimensional Data Mounting Dimensions PUMP SIZES TP16-45-45 TP16-65-45 TP16-65-65 TP16-85-45 TP16-85-65 TP16-85-85 TP16-100-45 TP16-100-65 TP16-100-85 TP16-100-100 TP16-115-45 TP16-115-65 TP16-115-85 TP16-115-100 TP16-115-115 TP16-150-45 TP16-150-65 TP16-150-85 TP16-150-100 TP16-150-115 TP16-150-150 TP16-180-45 TP16-180-65 TP16-180-85 TP16-180-100 TP16-180-115 TP16-180-150 TP16-180-180 TP16-200-45 TP16-200-65 TP16-200-85 TP16-200-100 TP16-200-115 TP16-200-150 TP16-200-180 TP16-200-200 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 A IN 1.89 2.11 2.11 2.32 2.32 2.32 2.48 2.48 2.48 2.48 2.64 2.64 2.64 2.64 2.64 3.01 3.01 3.01 3.01 3.01 3.01 3.33 3.33 3.33 3.33 3.33 3.33 3.33 3.55 3.55 3.55 3.55 3.55 3.55 3.55 3.55 B MM 48.01 53.59 53.59 58.93 58.93 58.93 62.99 62.99 62.99 62.99 67.06 67.06 67.06 67.06 67.06 76.45 76.45 76.45 76.45 76.45 76.45 84.58 84.58 84.58 84.58 84.58 84.58 84.58 90.17 90.17 90.17 90.17 90.17 90.17 90.17 90.17 IN 2.42 2.64 2.64 2.85 2.85 2.85 3.01 3.01 3.01 3.01 3.17 3.17 3.17 3.17 3.17 3.54 3.54 3.54 3.54 3.54 3.54 3.86 3.86 3.86 3.86 3.86 3.86 3.86 4.08 4.08 4.08 4.08 4.08 4.08 4.08 4.08 C MM 61.47 67.06 67.06 72.39 72.39 72.39 76.45 76.45 76.45 76.45 80.52 80.52 80.52 80.52 80.52 89.92 89.92 89.92 89.92 89.92 89.92 98.04 98.04 98.04 98.04 98.04 98.04 98.04 103.6 103.6 103.6 103.6 103.6 103.6 103.6 103.6 IN 5.90 6.11 6.33 6.33 6.54 6.76 6.49 6.70 6.92 7.08 6.65 6.86 7.08 7.24 7.40 7.02 7.23 7.45 7.61 7.77 8.14 7.34 7.55 7.77 7.93 8.09 8.46 8.78 7.55 7.76 7.98 8.14 8.30 8.67 8.99 9.20 SHIPPING WEIGHTS (Approx.) D MM 149.9 155.2 160.8 160.8 166.1 171.7 164.9 170.2 175.8 179.8 168.9 174.2 179.8 183.9 188.0 178.3 183.6 189.2 193.3 197.4 206.8 186.4 191.8 197.4 201.4 205.5 214.9 223.0 191.8 197.1 202.7 206.8 210.8 220.2 228.4 233.7 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com IN 6.91 7.12 7.34 7.34 7.55 7.77 7.50 7.71 7.93 8.09 7.66 7.87 8.09 8.25 8.41 8.03 8.24 8.46 8.62 8.78 9.15 8.35 8.56 8.78 8.94 9.10 9.47 9.79 8.57 8.77 8.99 9.15 9.31 9.68 10.00 10.21 MM 175.5 180.9 186.4 186.4 191.8 197.4 190.5 195.8 201.4 205.5 194.6 199.9 205.5 209.6 213.6 204.0 209.3 214.9 219.0 223.0 232.4 212.1 217.4 223.0 227.1 231.1 240.5 248.7 217.7 222.8 228.4 232.4 236.5 245.9 254.0 259.3 lbs. 26 28 30 31 33 35 34 36 38 39 39 41 43 44 46 44 47 49 50 52 54 52 54 56 57 59 61 63 60 62 64 65 67 69 71 73 kgs. 11.8 12.7 13.6 14.1 15.0 15.9 15.4 16.3 17.2 17.7 17.7 18.6 19.5 20.0 20.9 20.0 21.3 22.2 22.7 23.6 24.5 23.6 24.5 25.4 25.9 26.8 27.7 28.6 27.2 28.1 29.0 29.5 30.4 31.3 32.2 33.1 NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 - 3 Place Description . . . . . . . . . . Gear Pumps (Three-place) Flow Range . . . . . . . . . . . To 32 GPM Per Section Displacements . . . . . . . . . . . . . . . . To 3.904 C.I.R. Maximum Pressure to . . . . . . . . . . . . . . . 3000 PSI Maximum Speed to. . . . . . . . . . . . . . . . 3100 RPM Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . A or C Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . Journal Series TP16 Construction . . . . . . . . . Cast Iron Gear Plates with Aluminum Flange, Connector and Cover Plates GRESEN® - P16 - 3 PLACE Series TP16 Performance Data DISPLACEMENT/REVOLUTION (Theoretical) PUMP SIZES MAXIMUM PRESSURE MAXIMUM SPEED US Gallons Cubic Inches Liters Cubic Centimeters Imperial Gallons PSI BAR RPM P16 - 45 .0038 .878 .0144 14.388 .0031 3000 207 3100 P16 - 65 .0055 1.270 .0208 20.812 .0045 3000 207 3000 P16 - 85 .0072 1.663 .0273 27.252 .0059 3000 207 2900 P16 - 100 .0085 1.964 .0321 32.184 .0070 3000 207 2800 P16 - 115 .0097 2.241 .0367 36.723 .0080 3000 207 2600 P16 - 150 .0127 2.934 .0481 48.080 .0105 3000 207 2400 P16 - 180 .0152 3.511 .0575 57.535 .0126 2200 152 2100 P16 - 200 .0169 3.904 .0639 63.942 .0140 2000 138 1900 Note: Three-place pumps assembled from maximum displacement size sections should be checked for operating inlet conditions. Inlet vacuum should not exceed 5" Hg. @ normal speed and temperature. If “PD Factor” is not exceeded, place the largest displacement section in the rear position and use all inlet ports. All data based on SAE 10W oil at 150˚F. Available with Viton Seals for use with phosphate ester base fluids. How To Order ‘A’ denotes counterclockwise rotation ‘C’ denotes clockwise rotation Rotation Shaft Pump Size—Rear Section Pump Size—Middle Section Pump Size—Front Section Series Flange Connector Plate Cover Plate Tandem Pump TP16 - 115 - 100 - 85A - 5N33 Note: The average shipping weight will range between 40 and 80 pounds (18.1-36.3 kgs.). Note: Add prefix ‘V’ to pump model number (VTP16-) when ordering pumps with Viton Seals for use with phosphate ester base fluids. NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 189 GRESEN® - P16 - 3 PLACE Series TP16 - 3 Place Shafts Available 2 7/8" Dia. 13 Tooth Spline Flat Root Side Fit Torque Limit 184 Lbs./Ft. 5 7/8" Straight Shaft Torque Limit 184 Lbs./Ft. 1/4" x 1/4" x 1-3/4" Lg. Key Major Dia. 1.19 Full 1.16 Spline Flange Mtg. Surface .8585 .8535 .875 .874 Dia. 982 Spline Data Diametral Pitch . . . . . . . . 16/32 Pressure Angle . . . . . . . . . 30° No. Of Teeth . . . . . . . . . . . . . 13 Minor Dia. . . . . . . . . .722-.733 1.44 1.56 1.69 'F' Flange 'D' Flange 'E' 'J' Flanges 2.25 'F' Flange 1.64 'N' Flange 2.38 'D' Flange .06 1.50 .25 Flange Mounting Surface 2.50 'J' & 'E Flanges 2.45 'N' Flange Mounting Flanges Available D .44 (1,11) Wide Mounting Slots SAE ‘A’ 2-Bolt F Pad Mount 1.65 (41,9) 1.65 (41,9) 3.250 (82,5) Pilot 3.248 (82,4) Dia. 2.09 (53,1) 2.00 (50,8) 1.88 R (47,7) .87 (22,2) 1/2-13NC Depth 1.00 2 Places 4.18 (106,4) 1.75 (44,4) Mounting Surface 5.12 (130,0) N SAE ‘B’ 2-Bolt .56 (14,2) Dia. 2 Holes 1.65 (41,9) S 1.13 (28,7) .62 (15,7) P.T.O. Direct Mount Available with No. 2 Shaft Only SAE ‘B’ 4-Bolt 2.626 2.622 Typ .125 4.000 (101,6) Pilot 3.998 (101,5) Dia. 2.750 Pilot 2.748 Dia. .328 Dia. 2.87 (123,0) 6.88 (174,7) 1.312 5.75 (146,0) CL PTO Pilot .191 CL Shaft .200 .187 Mounting Surface 3.31 For Gresen® Repair Parts See Pages 493 - 505 190 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 - 3 Place Discharge Ports for Connector Plate and Cover Plate SAE 4-Bolt 3 4 NPT-Pipe Thread 8 BSPT-Pipe Thread .875 3/8-16UNC Depth .81 .43 * * SAE 12 Straight Thread 5 SAE 16 Straight Thread 9 .62 Dia. 1.875 .93* * 3/4" SAE 4-Bolt Conn. SAE 4-Bolt NPT Connectors Are Available. See Accessory Section *These dimensions locate 3/4-14 PT 1-5/16-12UN-2B 1-1/16-12UN-2B CL of bolt pattern only. GRESEN® - P16 - 3 PLACE Series TP16 Dimensional Data 1.85 To Determine Overall Pump Length Add together the dimensions that apply to the pump you are considering Flange Dimensions 1.6 Shaft Extension B= Flange Length C= Front Gear Plate Length D= 3.12 in. Connector Plate Length 79.25 mm 3.12 in. Connector Plate Length 79.25 mm G= Rear Gear Plate Length H= 2.06 in. Cover Plate Length 52.32 mm J= .75 in. Stud Extension 19.05 mm Total = Overall Length PUMP SIZE IN MM -45 -65 -85 -100 -115 -150 -180 -200 .86 1.07 1.29 1.45 1.61 1.98 2.30 2.51 21.84 27.18 32.77 36.83 40.89 50.29 58.42 63.75 NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 Location of Drive Shaft for Counterclockwise Rotation .82* 1.04 J H (.75) (2.06) 1/2-13NC Depth .81 Gear Plate Length .250 .187 – .250 .375 .200 Drawn for Clockwise Rotation Center Gear Plate Length F= ‘K’ 1.62 2.75 1.75 2.75 1.55 3.31 2.8 1.03 F (3.12) G 1.406 C .70* 1.56 3.12 B A 1/2-13UNC Depth .81 1.406 1-1/2" SAE 4-Bolt Conn. Suction .82* K 1.03 D (3.12) E .70* 1 Di .62 a. E= 2.6 ‘B’ D E F J N S 1-1/2" SAE 4-Bolt Conn. Common Suction 1 Di .62 a. A= FLANGE TYPE 1.56 3.12 2.06 This Suction Port Always Closed with Plug or Plate *These dimensions locate SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com CL of bolt pattern only. WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 191 GRESEN® - P16 - 3 PLACE Series TP16 - 3 Place Dimensional Data PD Factors The maximum size and number of sections of a tandem pump for a given application is limited to the torque capability of the input drive shaft and the spline coupling between the sections. To determine this capability, a “PD Factor” is used: Maximum allowable PD for the 7/8" drive shaft is 53. Maximum allowable PD for a coupling is also 53. When: P = PSI (The relief valve setting of each individual section). D = Displacement (In U.S. gallons per revolution of each individual section). Example: Assume a three-place pump TP16-150–150–100 with front and center sections on pressure at the same time at 2000 PSI, and with the rear section on pressure at 1500 PSI but not at the same time as the front and center sections: A. Drive Shaft: (1) PD = (2000) (.0127) + (2000) (.0127) = 50.8 vs. 53. Capability is OK (2) PD = (1500) (.0085) = 12.7 vs. 53. Capability is OK. B. Coupling between front and center sections: PD = (2000) (.0127) = 25.4 vs. 53. Capability is OK. C. Coupling between center and rear sections: PD = (1500) (.0085) = 12.7 vs. 53. Capability is OK. Note: For purpose of illustration, assume all three pump sections to be on pressure at the same time. A. Drive Shaft: PD = (2000) (.0127) + (2000) (.0127) + (1500) (.0085) = 63.5 vs. 53. Capability is not OK Because the PD Factor for the shaft is 53, operating all three sections at the same time (to relief valve pressure) would exceed the torque capability of the drive shaft. B. Coupling between front and center sections: PD = (2000) (.0127) + ( (1500) (.0085) = 35.1 vs. 53. Capability is OK Remember also that the PD factor for the coupling is 53. If the center and rear sections are on pressure at the same time, the coupling between the front and center sections must transmit the torque for the center and rear sections. 192 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 Description . . . . . . . . . . Priority Valve Gear Pumps Pump Flow Range . . . . . . . . . . . . . . . . To 38 GPM Priority Flow Range . . . . . . 2 to 10 GPM Standard Displacements . . . . . . . . . . . . . . . . To 3.904 C.I.R. Maximum Pressure to . . . . . . . . . . . . . . . 3000 PSI Maximum Speed to. . . . . . . . . . . . . . . . 3600 RPM GRESEN® - PVP16 Series PVP16 Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . A or C Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . Journal Series PVP16 Construction . . . . . . . . . . Cast Iron Gear Plate with Aluminum Flange and Cover (Valve) Plate Performance Data DISPLACEMENT/REVOLUTION (Theoretical) PUMP SIZES US Gallons MAXIMUM PRESSURE MAXIMUM SPEED Cubic Inches Liters Cubic Centimeters Imperial Gallons PSI BAR RPM PVP16 - 45 .0038 .878 .0144 14.388 .0031 3000 207 3600 PVP16 - 65 .0055 1.270 .0208 20.812 .0045 3000 207 3600 PVP16 - 85 .0072 1.663 .0273 27.252 .0060 3000 207 3400 PVP16 - 100 .0085 1.964 .0321 32.184 .0070 3000 207 3300 PVP16 - 115 .0097 2.241 .0367 36.723 .0080 3000 207 3100 PVP16 - 150 .0127 2.934 .0481 48.080 .0105 3000 207 2800 PVP16 - 180 .0152 3.511 .0575 57.535 .0125 2200 152 2500 PVP16 - 200 .0169 3.904 .0639 63.942 .0140 2000 138 2500 All data based on SAE 10W oil at 150˚F. Available with Viton Seals for use with phosphate ester base fluids. How To Order ‘A’ denotes counterclockwise rotation ‘C’ denotes clockwise rotation When viewed from drive shaft end Rotation Shaft Flange Cover Plate Pump Size Priority Flow* In GPM (+1/-0 GPM) Series Priority Valve Pump PVP16 - 115A - 2N3-3-13 Priority Flow Relief Valve Setting in 100’s (+/- 100 PSI) Example: 3.0 GPM—1300 PSI *Consult factory for priority flows over 10 GPM. Note: Add prefix ‘V’ to pump model number (VPVP16-) when ordering pumps with Viton Seals for use with phosphate ester base fluids. NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 193 GRESEN® - PVP16 Series PVP16 Shafts Available 7/8" Dia. 13 Tooth Spline Flat Root Side Fit 2 5 7/8" Straight Shaft 6 Torque limit 184 Lbs. Ft. Torque limit 184 Lbs. Ft. Major Dia. 1.56 1.44 1.69 'D' Flange 'F' Flange 'J' 'G' & 'E' Flanges 1.635 'N' Flange Torque limit 105 Lbs. Ft. Available on –45 through –115 sizes only 3/16" x 3/16" x 1-1/4" Lg. Key 1/4" x 1/4" x 1-3/4" Lg. Key .8585 .8535 987 982 1.19 Full 1.16 Spline 3/4" Straight Shaft .832 .749 .Dia. .827 .748 .875 .874 Flange Mtg. Surface Flg Mtg Surface 'N' Flange .06 1.50 2.38 'D' Flange 2.25 'F' Flange 2.50 'J' & 'E' Flanges 2.45 'N' Flange .25 Spline Data Diametral Pitch . . . . . . . 16/32 Pressure Angle . . . . . . . . . 30° No. Of Teeth . . . . . . . . . . . . 13 Minor Dia. . . . . . . . . .722-.733 1.62 1.81 'F' Flange 1.94 'D' Flange 2.06 'E' & 'J' Flanges 2.01 'N' Flange Flange Mounting Surface Mounting Flanges Available D SAE ‘A’ 2-Bolt .44 (1,11) Wide Mounting Slots 1.65 (41,9) Pad Mount F 1.65 (41,9) 3.250 (82,5) Pilot 3.248 (82,4) Dia. 2.00 (50,8) 2.09 (53,1) 1.88 R (47,7) .87 (22,2) 1/2-13NC Depth 1.00 2 Places 4.18 (106,4) 5.12 (130,0) N SAE ‘B’ 2-Bolt S .56 (14,2) Dia. 2 Holes 1.13 (28,7) 1.75 (44,4) Mounting Surface .62 (15,7) P.T.O. Direct Mount Available with No.2 Shaft Only 2.626 2.622 Typ .125 1.65 (41,9) 4.000 (101,6) Pilot 3.998 (101,5) Dia. 2.750 Pilot 2.748 Dia. 328 Dia. 2.87 (123,0) 6.88 (174,7) 1.312 5.75 (146,0) CL PTO Pilot .191 CL Shaft .200 .187 Mounting Surface 3.31 For Gresen® Repair Parts See Pages 493 - 505 194 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 GRESEN® - PVP16 Series PVP16 Cover Plates Available 3 Side Ported SAE 4-Bolt SAE 8 (3/4-16UNF-2B) Priority Discharge .75 Dia. 1 1/4" SAE 4-Bolt Conn. Suction 7/16-14NC Depth .88 * .43 2.313 a. * 1.2 5D i 1.875 .93 3/8-16NC Depth .88 3/4" SAE 4-Bolt Conn. Secondary Discharge .875 * 1.15 * .59 1.188 SAE 4-Bolt NPT Connectors Are Available. See Accessory Section 5 Side Ported Straight Thread SAE 8 (3/4-16UNF-2B) Priority Discharge 2.12 SAE 10 (7/8-14UNF-2B) Secondary Discharge SAE 20 (1 5/8-12UN-2B) Suction 1.31 3.44 6 Rear Ported Straight Thread CL of Drive Shaft for Counterclockwise Rotation 1.38 SAE 8 (3/4-16UNF-2B) .56 Priority Discharge 2.03 2.03 .82 1.65 .27 CL of Drive Shaft for Clockwise Rotation 2.79 SAE 20 (1-5/8-12UN-2B) Suction 2.79 SAE 10 (7/8-14UNF-2B) Secondary Discharge CL of Drive Shaft *These dimensions locate NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 CL of bolt pattern only. SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 195 GRESEN® - PVP16 Series PVP16 Dimensional Data Mounting Dimensions SHIPPING WEIGHTS (Approx.) FLANGE TYPE PUMP SIZES D A 3.79 4.00 4.22 4.38 4.54 4.91 5.23 5.44 PVP16 - 45 PVP16 - 65 PVP16 - 85 PVP16 - 100 PVP16 - 115 PVP16 - 150 PVP16 - 180 PVP16 - 200 B 4.60 4.81 5.03 5.19 5.35 5.72 6.04 6.25 E&J C 5.92 6.13 6.35 6.51 6.67 7.04 7.36 7.57 A 4.92 5.13 5.35 5.51 5.67 6.04 6.36 6.57 B 5.73 5.94 6.16 6.32 6.48 6.85 7.17 7.38 F C 7.05 7.26 7.48 7.64 7.80 8.17 8.49 8.70 A 3.92 4.13 4.35 4.51 4.67 5.04 5.36 5.57 B 4.73 4.94 5.16 5.32 5.48 5.85 6.17 6.38 C 6.05 6.26 6.48 6.64 6.80 7.17 7.49 7.70 lbs. 13 14 15 16 17 18 20 21 kgs. 5.9 6.4 6.8 7.3 7.7 8.2 9.1 9.5 Mounting Dimensions SHIPPING WEIGHTS (Approx.) FLANGE TYPE PUMP SIZES N PVP16 - 45 PVP16 - 65 PVP16 - 85 PVP16 - 100 PVP16 - 115 PVP16 - 150 PVP16 - 180 PVP16 - 200 A 3.67 3.88 4.10 4.26 4.42 4.79 5.11 5.32 B 4.48 4.69 4.91 5.07 5.23 5.60 5.92 6.13 S C 5.80 6.01 6.23 6.39 6.55 6.92 7.24 7.45 A 5.48 5.69 5.91 6.07 6.23 6.60 6.92 7.13 B 6.29 6.50 6.72 6.88 7.04 7.41 7.73 7.94 C 7.61 7.82 8.04 8.20 8.36 8.73 9.05 9.26 lbs. 13 14 15 16 17 18 20 21 kgs. 5.9 6.4 6.8 7.3 7.7 8.2 9.1 9.5 D Dimensions FLANGE TYPE Priority Flow 196 CAT. NO CAT. NO CAT. NO CAT. NO CAT. NO CAT. NO CAT. NO CAT. NO 2 2 to 3 GPM 3 3 to 4 GPM 4 4 to 5 GPM 5 5 to 6 GPM 6 6 to 7 GPM 7 7 to 8 GPM 8 8 to 9 GPM 9 9 to 10 GPM WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com D E F J N S IN MM .250 .187 6.35 4.75 .250 .375 .250 6.35 9.52 6.35 NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 GRESEN® - PVP16 Series PVP16 Dimensional Data 2.25 Priority Discharge 4.42 .56 3.47 2.03 2.03 1.65 .27 * Secondary Discharge 1.85R B 2.75 2.75 Drawn for Counterclockwise Rotation D B Relief Valve Adjustment CL of Priority Discharge Suction 5.12 3.68 3.68 1.38 .82* CL of Secondary Discharge A C CL of Suction Drawn for Clockwise Rotation ±.060 * These dimensions locate CL of bolt pattern only. NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 197 ntertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial ntertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial ntertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen® Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories Cylinders / Prince Cylinders & Pumps / Chief Cylinders / ® Description . . . . . . . . . . . . . . . . . . . Clutch Pumps Flow Range . . . . . . . . . . . . . . . . . . . . . To 38 GPM Displacements . . . . . . . . . . . . . . . . To 3.904 C.I.R. Maximum Pressure to . . . . . . . . . . . . . . . 3000 PSI GRESEN® - CP16 Series CP16 Maximum Speed to. . . . . . . . . . . . . . . . 3600 RPM Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . A or C Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . Journal Series CP16 Construction . . . . . . . . . Cast Iron Gear Plates with Aluminum Flange and Cover Plate Performance Data PUMP SIZES DISPLACEMENT/REVOLUTION (Theoretical) MAXIMUM PRESSURE ‘V’ BELT DRIVE Clutch #1 Clutch #2 Clutch #3 PSI BAR PSI BAR PSI BAR MAXIMUM FLAT SPEED RIBBED Drive PSI BAR RPM US Gallons Cubic Inches Liters Cubic Centimeters Imperial Gallons P16 - 45 .0038 .878 .0144 14.39 .0031 3000 207 3000 207 3000 207 3000 207 3600 P16 - 65 .0055 1.270 .0208 20.83 .0045 3000 207 3000 207 3000 207 3000 207 3600 P16 - 85 .0072 1.663 .0273 27.27 .0060 2800 193 3000 207 3000 207 3000 207 3400 P16 - 100 .0085 1.964 .0321 32.21 .0070 2400 165 3000 207 3000 207 3000 207 3300 P16 - 115 .0097 2.241 .0367 36.75 .0080 2000 138 2900 200 3000 207 2900 200 3100 P16 - 150 .0127 2.934 .0481 48.11 .0105 1500 103 2600 179 3000 207 2600 179 2800 P16 - 180 .0152 3.511 .0575 57.57 .0125 1200 83 2100 145 2200 152 2100 145 2500 P16 - 200 .0169 3.904 .0639 64.02 .0140 1100 76 1900 131 2000 138 1900 131 2200 All data based on SAE 10W oil at 150˚F. Available with Viton Seals for use with phosphate ester base fluids. Torque Ratings Clutch Option How To Order ‘A’ denotes counterclockwise rotation ‘C’ denotes clockwise rotation When viewed from drive shaft end Rotation Pump Size Rating Clutch # 1 75 ft/lbs. Clutch # 2 125 ft/lbs. Clutch # 3 200 ft/lbs. Clutch Cover Plate Series Clutch Pump S=With Switch Kit O=Without Switch Kit CP16 - 115A - 24-S Note: Add prefix ‘V’ to pump model number (VCP16-) when ordering pumps with Viton Seals for use with phosphate ester base fluids. NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 199 Cover Plates Available 2 Rear Ported NPTF 7 Rear Ported BSPT Side Ported SAE 4-Bolt 3 .875 1.188 .43 2.75 2.62 * .59 7/16-14NC Depth .88 * .93 1" NPT Suction 1.38 3/4" NPT Discharge 1.38 1.15 .62 Dia. * 2.313 5 3/4" SAE 4-Bolt Conn. 1.875 Di a. 3/8-16NC Depth .88 1.2 GRESEN® - CP16 Series CP16 1-1/4" SAE 4-Bolt Conn. Discharge Side Suction Side SAE 4-Bolt NPT Connectors Are Available. See Accessory Section 4 Rear Ported NPTF 8 Side Ported BSPT 6 Side Ported Straight Thread 5 SAE 12 (1-1/16-12UN-2B) 3/4" NPT 1" NPT Discharge Side Suction Side Discharge Side Rear Ported Straight Thread 2.75 * These dimensions locate CL of bolt pattern SAE 20 (1-5/8-12UN-2B) SAE 16 (1-5/16-12UN-2B) only Suction Suction Side 2.62 1.38 SAE 12 (1-1/16-12UN-2B) Discharge 1.38 Dimensional Data Clutch No. 4 Flat Ribbed Belt Drive Clutch No. 1 & 2 ‘V’ Belt Drive Sheave Grooves for 'A' Section Belts Only Suction for Clockwise Rotation – ‘C’ Discharge for Counterclockwise Rotation – ‘A’ 1.85R 5.35 E E Dia. Dia. 4.12 * 1.65 .82 2.00 C D Max. 200 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 C .62 D Max. 1/2 - 13NC Depth 1.12 Min. 2 Holes A* B±.060 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com .45 .875 1.750 NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 Dimensional Data Mounting Dimensions PUMP SIZES P16-45 P16-65 P16-85 P16-100 P16-115 P16-150 P16-180 P16-200 WITH CLUTCH #1 A B IN MM 2.53 64.3 2.74 69.6 2.96 75.2 3.12 79.3 3.28 83.3 3.65 92.7 3.97 100.8 4.18 106.2 IN 3.54 3.75 3.97 4.13 4.29 4.66 4.98 5.19 C MM 89.9 95.3 100.8 104.9 109.0 118.4 126.5 131.8 IN 2.41 2.41 2.41 2.41 2.41 2.41 2.41 2.41 WITH CLUTCH #2 D MM 61.2 61.2 61.2 61.2 61.2 61.2 61.2 61.2 IN 3.96 3.96 3.96 3.96 3.96 3.96 3.96 3.96 E MM 100.6 100.6 100.6 100.6 100.6 100.6 100.6 100.6 IN 6.12 6.12 6.12 6.12 6.12 6.12 6.12 6.12 C MM 155.5 155.5 155.5 155.5 155.5 155.5 155.5 155.5 IN 2.38 2.38 2.38 2.38 2.38 2.38 2.38 2.38 D MM 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 IN 4.07 4.07 4.07 4.07 4.07 4.07 4.07 4.07 MM 103.4 103.4 103.4 103.4 103.4 103.4 103.4 103.4 E IN 6.71 6.71 6.71 6.71 6.71 6.71 6.71 6.71 MM 170.4 170.4 170.4 170.4 170.4 170.4 170.4 170.4 GRESEN® - CP16 Series CP16 Mounting Dimensions PUMP SIZES P16-45 P16-65 P16-85 P16-100 P16-115 P16-150 P16-180 P16-200 With Clutch #A A IN MM 2.53 64.3 2.74 69.6 2.96 75.2 3.12 79.3 3.28 83.3 3.65 92.7 3.97 100.8 4.18 106.2 B IN 3.54 3.75 3.97 4.13 4.29 4.66 4.98 5.19 Clutch No.3 Direct Drive C IN MM 3.05 77.5 3.05 77.5 3.05 77.5 3.05 77.5 3.05 77.5 3.05 77.5 3.05 77.5 3.05 77.5 MM 89.9 95.3 100.8 104.9 109.0 118.4 126.5 131.8 2.394 1.20 * Shipping Weights (Approximate) D IN 4.07 4.07 4.07 4.07 4.07 4.07 4.07 4.07 MM 103.4 103.4 103.4 103.4 103.4 103.4 103.4 103.4 E IN 5.75 5.75 5.75 5.75 5.75 5.75 5.75 5.75 MM 146.0 146.0 146.0 146.0 146.0 146.0 146.0 146.0 Clutch #1 Lbs. Kgs. 18.5 8.4 19.5 8.8 20.5 9.3 21.5 9.8 22.5 10.2 23.5 10.7 25.5 11.6 26.5 12.0 Clutch #2 Lbs. Kgs. 22.5 10.2 23.5 10.7 24.5 11.1 25.5 11.6 26.5 12.0 27.5 12.5 29.5 13.4 30.5 13.8 5.35 * 2379 2377 2.008 6.14 Dia. NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 4.12 .82 5.34 Max. A* B ±.060 *These dimensions locate Clutch #4 Lbs. Kgs. 22.5 10.2 23.5 10.7 24.5 11.1 25.5 11.6 26.5 12.0 27.5 12.5 29.5 13.4 30.5 13.8 3/8-24UNF Depth 4 Holes Use Spicer Yoke No. 2-2-329 Pilot Dia. * 1.00 Clutch #3 Lbs. Kgs. 28.6 13.0 29.6 13.4 30.6 13.9 31.6 14.3 32.6 14.8 33.6 15.2 35.6 16.1 36.6 16.6 ±.45 CL of bolt pattern only. SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 201 GRESEN® - CP16 Series CP16 Operating Notes 1. Detailed installation and operating instructions are included in each clutch-pump package. Consult those SAE 20 instructions before installation and/or operation. 1-5/8-12UN-2B THREAD 2. Clutch Data: Suction Port Adapter For No.5 Body. Clutch No. 1 – 12 V.D.C.; 4.26 amps; Order kit number 15369 2.82 ohms @ 20°C; 75 Lb. Ft. Clutch No. 2 – 12 V.D.C.; 4.36 amps; SAE 16 2.75 ohms @ 20°C; 125 Lb. Ft. 1-5/16-12UN-2B THREAD Clutch No. 1 – 12 V.D.C.; 4.58 amps; 2.62 ohms @ 20°C; 200 Lb. Ft. 3. Burnishing: If full rated torque (or system pressure) is required at start-up, burnishing or cycling of the clutch will be necessary. Burnishing of the clutch can be accomplished by running the engine between 2500 and 3000 RPM and cycling the clutch on and off against the system relief valve. The relief valve should be set at 75% of the maximum pressure rating as shown in the chart on the front page of this brochure. The clutch should be cycled 50 times at a rate of 10 to 15 cycles per minute. 4. Voltage: The torque capability of the clutch varies with the actual voltage measured at the clutch. Do not operate at less than 11.5 volts. 5. For maximum clutch life: #1 & #2 should be mounted to run in ‘C’ rotation. #3 should be mounted to run in ‘A’ rotation, (looking at the front of the clutch). Electric Clutch Switch: Order Kit No. 33520 For Gresen® Repair Parts See Pages 493 - 505 202 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 Description . . . . . . . . . . . . . . . . . . . Dump Pumps Flow Range . . . . . . . . . . . . . . . . . . . . . To 38 GPM Displacements . . . . . . . . . . . . . . . . To 3.511 C.I.R. Maximum Pressure to . . . . . . . . . . . . . . . 3000 PSI GRESEN® - DP16 Series DP16 Maximum Speed to. . . . . . . . . . . . . . . . 2500 RPM Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . A or C Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . Journal Construction . . . . . . . Aluminum Flange and Cover Cast Iron Gear and Valve Housing Series DP16 Performance Data PUMP SIZES DISPLACEMENT/REVOLUTION (Theoretical) US Gallons MAXIMUM PRESSURE MAXIMUM SPEED Cubic Inches Liters Cubic Centimeters Imperial Gallons PSI BAR RPM DP16-45 .0038 .878 .0144 14.388 .003 3000 207 2500 DP16-65 .0055 1.270 .0208 20.812 .005 3000 207 2500 DP16-85 .0072 1.663 .0273 27.252 .006 3000 207 2500 DP16-100 .0085 1.964 .0321 32.184 .007 3000 207 2500 DP16-115 .0097 2.241 .0367 36.723 .008 3000 207 2500 DP16-150 .0127 2.934 .0481 48.080 .011 3000 207 2500 DP16-180 .0152 3.511 .0575 57.535 .013 3000 207 2500 All data based on SAE 10W oil at 150°F. How To Order ‘A’ denotes counterclockwise rotation ‘C’ denotes clockwise rotation When viewed from drive shaft end Pump Port A=NPT, B=BSPT Flange Shaft Rotation Valve Series Shift M=Manual, P=Pneumatic Size Valve Port A=NPT, B=BSPT Series Relief Valve Setting 20=2000 PSI 25=2500 PSI Dump Pump DP 16-180A-2NA-V16M-A-20 NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 203 GRESEN® - DP16 Series DP16 Shafts Available 2 7/8" Dia. 13 Tooth Spline Flat Root Side Fit 7/8" Straight Shaft 5 Torque Limit 184 Lbs. Ft. Available with ‘N’ & ‘S’ Flanges Only Torque Limit 184 Lbs. Ft. Available with ‘F’ Flanges Only 1/4" x 1/4" x 1-3/4" Lg. Key 1.19 1.16 Major Dia. Flange Mtg. Surface Full Spline .8585 .8535 .875 .874 Dia. 982 'N' Flange 1.69 .06 1.50 .25 Spline Data Flange Mounting Surface 2.25 Diametral Pitch . . . . . . . . 16/32 Pressure Angle . . . . . . . . . 30° No. Of Teeth . . . . . . . . . . . . . 13 Minor Dia. . . . . . . . . .722-.733 Flanges Available with Manual Valve Operation F Pad Mount SAE ‘B’ 2-Bolt N S P.T.O. Direct Mount [litres/min] 18,9 37,9 56,8 75,7 2500 172 2250 155 2000 138 1750 120 .328 Dia. [bar] 4.000 Pilot 3.998 Dia. 1.65 PSI 2.626 2.622 Typ. 9/16" Dia. 2 Holes 1.43 R 6.88 2.750 Pilot 2.748 Dia. 1.312 .375 2.38 R 2.875 A DP16-45 & DP-65 5.750 10 15 .191 CL PTO Pilot .250 CL Shaft A B DP16-85 Thru DP16-180 Mounting Surface 5 .125 A Face of Value B Mounting Surface 20 Flanges Available with Air Valve Operation F Pad Mount N SAE ‘B’ 2-Bolt S Use Spicer Sleeve Yoke No. 10-3-33X Only 1.43 R Port '2' (Air) P.T.O. Direct Mount Port '2' (Air) 2.626 2.622 Typ. 9/16" Dia. 2 Holes 1.43 R A A DP16-45 Thru DP16-85 .125 1.65 1.65 2.750 Pilot 2.748 Dia. 4.000 Pilot 3.998 Dia. .328 Dia. 2.00 1/2-13NC Depth 1.00 2 Places .875 A Mounting Surface 204 1.13 1.750 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 2.38 R 2.875 6.88 1.312 .375 5.750 CL PTO Pilot Mounting Surface B SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com B .191 .250 DP16-100 Thru CL Shaft DP16-180 Mounting Surface A B NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 Dimensional Data for Pump with Manual Valve Mounting Dimensions FLANGE TYPE MOTOR SIZES DP16-45 DP16-65 DP16-85 DP16-100 DP16-115 DP16-150 DP16-180 F N A IN .07 .14 .36 .52 .68 1.05 1.37 B MM 1.78 3.56 9.15 13.21 17.28 26.68 34.81 IN 4.67 4.88 5.10 5.26 5.42 5.79 6.11 A MM 118.7 124.0 129.5 133.7 137.7 147.1 155.3 B IN MM .32 8.13 .11 2.79 .11 2.79 .27 6.86 .43 10.92 .80 20.32 1.12 28.45 SHIPPING WEIGHTS (Approx.) S IN 4.42 4.63 4.85 5.01 5.17 5.54 5.86 A MM 112.3 117.6 123.2 127.3 131.3 140.7 148.8 IN 1.50 1.71 1.93 2.09 2.25 2.62 2.94 B MM 38.10 43.43 49.02 53.09 57.15 66.55 74.68 IN 6.23 6.44 6.66 6.82 6.98 7.35 7.69 MM 158.3 163.6 169.2 173.3 177.3 186.7 195.3 lbs. 20.5 20.5 20.5 21.5 21.5 21.5 22.5 kgs. 9.2 9.2 9.2 9.7 9.7 9.7 10.1 GRESEN® - DP16 Series DP16 1.21 6.65 .34 .34 6.06 5.33 4.38 1.85R Neutral Lower Neutral Raise Discharge Port 2.77 2.96 5.92 .432 1.65 Optional Shift From This End .376 Hole Dia. .373 2.38 A Optional 3RD Line Port 1.15 5.15 6.81 3.44 Face Of Valve Flange Mounting Surface 9.53 Front View CL Of Drive Shaft For Counterclockwise Rotation Suction Port 1" Pipe Thread 1.38 4.38 Discharge Port 3/4" Pipe Thread 2.00 1.65 .82 .82 2.00 CL Of Drive Shaft For Clockwise Rotation B±.060 All Views Drawn With 'N' Flange And For Clockwise Rotation 2.93 3.63 5.13 Optional Third Line Port 3/4" Pipe Thread Rear View * These dimensions locate CL of bolt pattern only For Gresen® Repair Parts See Pages 493 - 505 NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 205 GRESEN® - DP16 Series DP16 Dimensional Data for Pump with Air Valve Mounting Dimensions FLANGE TYPE MOTOR SIZES DP16-45 DP16-65 DP16-85 DP16-100 DP16-115 DP16-150 DP16-180 F N A IN 2.01 1.80 1.58 1.42 1.26 .89 .57 B MM 51.07 45.74 40.15 36.08 32.02 22.61 14.48 IN 4.67 4.88 5.10 5.26 5.42 5.79 6.11 A MM 118.7 124.0 129.6 133.7 137.7 147.1 155.3 IN 2.26 2.05 1.83 1.67 1.51 1.14 .82 MM 57.53 52.09 46.50 42.43 38.37 28.97 20.84 SHIPPING WEIGHTS (Approx.) S B IN 4.42 4.63 4.85 5.01 5.17 5.54 5.86 A MM 112.3 117.7 123.2 127.3 131.4 140.8 148.9 B IN MM .44 11.18 .23 5.84 .01 .25 .15 3.81 .31 7.88 .68 17.28 1.00 25.41 IN 6.23 6.44 6.66 6.82 6.98 7.35 7.69 MM 158.3 163.6 169.2 173.3 177.6 186.8 195.4 lbs. 20.5 20.5 20.5 21.5 21.5 21.5 22.5 kgs. 9.2 9.2 9.2 9.7 9.7 9.7 10.1 9.32 8.00 Flg. Mtg. Surface Discharge Port 4.38 1.85R A Port '2' (Air) 1/8-Pipe Thread 2.77 2.96 5.92 1.65 2.38 3.44 3.09 Optional 3RD Line Port 7.09 9.53 8.75 Front View CL Of Drive Shaft For Counterclockwise Rotation Suction Port 1" Pipe Thread 1.38 4.38 Discharge Port 3/4" Pipe Thread 2.00 1.65 .82 .82 2.00 B±.060 All Views Drawn With 'N' Flange And For Clockwise Rotation CL Of Drive Shaft For Clockwise Rotation 2.93 3.63 5.13 Port '1' (Air) 1/8" Pipe Thread Optional Third Line Port 3/4" Pipe Thread Rear View * These dimensions locate CL of bolt pattern only NOTES: 1—Two-Line Operation: As shipped, pumps are assembled for two-line operation, i.e., one suction line from the tank, one pressure line to the cylinder. The two-line system is recommended for intermittent operation only. 2—Three-Line Operation: Uses one suction line from the tank, one return line to the tank, and one pressure line to the cylinder. Use of a filter in the return line requires a check valve between the pump and filter to prevent filter backwash. The three-line system is recommended for continuous operation applications. 3—A minimum of 60 PSI air pressure is required to shift the spool full travel to either raise or lower operating position. Pressure at port “1” (air) moves the spool to raise position. Pressure at port “2” (air) moves the spool to lower position. When vented to atmosphere, ports “1” and “2” allow spring return of the spool to neutral from either raise or lower position. 206 WORLDWIDE PHONE 1-727-796-1300 FAX 1-727-797-8849 SALES OFFICE HOURS 8 A.M. TO 8 P.M. EASTERN TIME www.herculeshydraulics.com NORTH AMERICA PHONE 1-800-333-5617 FAX 1-800-759-6391
Similar documents
eastern chart (northern area)
W a f Muske s i a ia T e IN d C n J n S T Io S H NL Bra tai MTC ard TL Region 8V (W PSI m ton Essex I TED TL rd RG blic LD Moun Lagu R Ford IN NI Capital Chatha IE R6 8V Boonngston UN VR radfo renc...
More information