The Ultra-Low Profile EMI/RFI Plug and Backshell Assembly
I
nnovative shielded low profile right angle connector plug and backshell assemblies reduce
clearance requirements without compromising ruggedness or shielding performance.
Available in Series 801 double-start, Series 804 QDC push-pull, and Series 805 triple-start,
Cobra assemblies provide optimal low-profile cable routing and legendary Mighty Mouse
connector performance in a single package. Each Cobra assembly is equipped with a removable
rear cover and gasket for easy crimp or solder contact termination of the connector. Both pin
and socket versions are available for both crimp and solder terminated versions. Integrated lowprofile backshell is equipped with an EMI/RFI shield termination platform and a shrink boot lip.
The ultra-lightweight assembly may be clocked in eight different angle orientations for additional
flexibility in cable routing. Connectors are equipped with polarization keying to prevent mismating. Glenair Mighty Mouse Cobra connector and backshell assemblies mate with available
square flange and jam nut receptacles from each respective connector series. Fourteen contact
arrangements are available, all with Size #23 contacts from shell size 5 to shell size 21 with 3-130
contacts respectively. Connector shells are aluminum alloy or stainless steel.
ƒƒSpace-saving design
features one-piece
machined and brazed
connector shell and
right angle backshell for
minimum height and
optimal EMI performance.
ƒƒMaster key clocking
enables easy cable entry/
exit routing in eight angles
ƒƒRemovable rear cover
and gasket provides easy
access to end of connector
for crimp or solder contact
termination
For more information
contact Glenair at
818-247-6000 or
visit our website at
www.glenair.com
MIGHTY MOUSE
805-061 triple-start with self-locking
coupling nut, exploded view
Cobra
T E C H N I C A L S P E C I F I C AT I O N S
B
Thread
How To Order Mighty Mouse Cobra Plug Connector and Backshell Assemblies
801-069-26
Sample Part Number
ZNU
Connector Series and Mighty
Mouse Cobra Basic Part Number
801-069-26 Double-Start self-locking plug
with ratchet mechanism (the clicker)
804-066-06 QDC Push-Pull plug
805-061-16 Triple-Start plug with ratcheting
anti-decoupling mechanism
Material/Finish
M, MT, NF, ZNU, Z1 - See Table I
8-13
P
A
1
Master
Key
05
F
Shell Size - Contact Arrangement See Table V - A: 801-069 B: 804-066 C: 805-061
Contact Style
A = Pin, solder B = Socket, solder P = Pin, Crimp S = Socket, crimp
Polarization Key Position
A, B, C, D, E, F - See Table III
Cable Exit Direction
1, 2, 3, 4, 5, 6, 7, 8 - See Table IV
Cable Entry Size
See Table VI
Specifications
•
•
•
•
•
•
•
•
•
•
Current Rating: #23 5 Amps
Test Voltage (DWV) #23: 500 VAC Sea Level
Insulation Resistance: 5000 megohms minimum
Contact Resistance: 73 millivolt drop at 5 Amp test current
Mating Cycles Series 801 and 804: 2000; Series 805: 500
Operating Temperature: -55° C. to +150° C.
Shielding Effectiveness: 50 dB min from 100MHz to 1000MHz.
Magnetic Permeability: 2.0µ
Vibration: 37g / Shock: 300g
Immersion, mated: 1meter water immersion for 1 hour
Materials/finish
•
•
•
•
•
Contacts: Copper alloy, gold plated
Backshell Housing and Lid: Aluminum or Stainless Steel
Backshell Sealing Gasket and Interfacial Seal: Fluorosilicone
Screws: 300 Series Stainless Steel
Insulator: LCP
Notes
• Rear insulator grommet not supplied.
• Cobra plug connectors mate with respective series receptacles
with same polarization and opposite contact gender.
• Hand crimp tool: P/N 809-015. Positioner for hand tool: P/N
809-005. Insertion/extraction tool P/N 809-088.
• Crimp barrel accommodates 22, 24, 26 and 28 gage wire.
• All Cobra plugs equipped with Size #23 contacts.
Symbol
M
NF
MT
ZNU
Z1
Table I: Shell Material/Finish
Finish
Electroless Nickel (RoHS)
Aluminum Cad/O.D. over Electroless Nickel
Alloy
Nickel-PTFE (RoHS)
Black Zinc Nickel over Electroless Nickel
Stainless
Passivate
Steel
Material
ØC
J
Table III: Key Positions
Table IV: Exit Direction
Direction
C°
1
0°
2
45°
3
90°
4
135°
5
180°
6
225°
7
270°
8
315°
C°
Table VI - Cable Entry
Code
Entry Size
02
.125
03
.188
04
.250
B° A°
05
.313
06
.375
07
.438
08
.500
09
.563
A°
B°
10
.625
A
150°
210°
11
.688
Master
B
75°
210°
12
.750
Key
C
95°
230°
13*
.813
D
140°
275°
14*
.875
E
75°
275°
15*
.938
F
95°
210°
16*
1.000
17*
1.063
Direction 2 Shown
* Entry codes 13-17 not available
for Series 804 Cobra
Table V - Shell Size/Contact Arrangements
A: 801-069
B: 804-066
C: 805-061
Shell
Contact
Max Shell
Contact
Max Shell
Contact
Max
Size Arrangement Entry Size Arrangement Entry Size Arrangement Entry
5
5-3
03
5
5-3
03
8
8-4, 8-6, 8-7
04
6
6-4, 6-6, 6-7
04
6
6-4, 6-6, 6-7
04
9
9-10
05
7
7-10
05
7
7-10
05
10
10-13
06
8
8-13
06
8
8-13
06
11
11-19
07
9
9-19
07
9
9-19
07
12
12-26
08
10
10-26
08
10
10-26
08
13
13-31
09
11
11-31
09
12
12-37
10
15
15-37
10
13
13-37
10
14
14-55
12
18
18-55
12
16
16-55
12
19
19-85
13
17
17-85
13
21
21-100
15
19
19-100
15
23
23-130
17
21
21-130
17
TABLE I - MATERIAL / FINISH CLASS
SHELL MATERIAL
FINISH
ALUMINUM ALLOY ELECTROLESS NICKEL (RoHS)
ALUMINUM ALLOY NICKEL-PTFE (RoHS)
OLIVE DRAB CADMIUM OVER
ALUMINUM ALLOY
ELECTROLESS NICKEL
BLACK ZINC-NICKEL OVER
ALUMINUM ALLOY
ELECTROLESS NICKEL (RoHS)
STAINLESS STEEL PASSIVATE (RoHS)
UNLESS OTHERWISE SPECIFIED
COVER
9. REAR INSULATOR GROMMET NOT SUPPLIED.
8. THIS CONNECTOR MATES WITH ALL QUICK COUPLING, HIGH DENSITY RECEPTACLE
CONNECTORS WITH SAME POLARIZATION AND OPPOSITE CONTACT GENDER
(801-003 THROUGH 801-006 AND 801-009 THROUGH 801-012).
7. CONTACT ARRANGEMENT, CONTACT GENDER, KEY POSITIONS, AND SHELL
ORIENTATION SHOWN ARE FOR REFERENCE ONLY.
6. CRIMP TOOL DATA:
A. HAND CRIMP TOOL: GLENAIR PART NO. 809-015.
B. POSITIONER FOR HAND TOOL: GLENAIR PART NO. 809-005.
C. INSERTION/EXTRACTION TOOL: GLENAIR PART NO. 809-088.
5. CRIMP BARREL ACCOMMODATES 22, 24, 26, AND 28 GAGE WIRE.
4. CONSULT FACTORY FOR ADDITIONAL CONTACT ARRANGEMENTS AND/OR SHELL
ORIENTATIONS.
3. CONTACTS ARE SIZE 23.
GASKET
REAR INSULATOR
GROMMET NOT
SUPPLIED
2. MATERIAL / FINISH:
PLUG BARREL, COUPLING NUT, HOUSING, COVER - ALUMINUM
ALLOY OR STAINLESS STEEL / SEE TABLE I
INSULATOR - LCP / NONE
INTERFACIAL SEAL, GASKET - FLUOROSILICONE / NONE
CONTACT - COPPER ALLOY / GOLD PLATE PER ASTM B 488, TYPE II,
CODE C, CLASS 1.25 (.00005 MIN THK), OVER A SUITABLE UNDERPLATE
CONTACT RETENTION CLIP - BERYLLIUM COPPER ALLOY / NONE
HARDWARE - STAINLESS STEEL / PASSIVATE OR BLACK OXIDE
RETAINING WIRE - TORLON / NONE
DETENT SPRING / RIVET - STAINLESS STEEL / PASSIVATE
1. ASSEMBLY TO BE IDENTIFIED WITH GLENAIR'S NAME, PART NUMBER,
AND DATE CODE, SPACE PERMITTING.
NOTES:
CONTACT GLENAIR FOR ADDITIONAL FINISHES
Z1
ZNU
NF
CLASS
M
MT
REV
A
B
± 1/16
± 2°
.XXX
.XX
± .015
± .03
B/F 10C5078 P/C
80
DO NOT SCALE THIS DRAWING
ANGLES
DECIMALS
FRACTIONS
03/05/12
03/05/12
03/05/12
øA
03/05/12
03/05/12
APPROVED
RELEASE DATE
ORIGINAL
RELEASE DATE
APPROVED
EAG
GSB
EAG
1
SCALE
N.A.
WEIGHT
N.A.
SHEET
1 OF
801-069
CODE IDENT. NO. SIZE DRAWING NO.
06324 A
PLUG CONNECTOR,
SERIES 801, RATCHETING,
COBRA STYLE
F
1211 AIR WAY - GLENDALE - CALIFORNIA 91201
TITLE
FACE VIEW OF PLUG
AS VIEWED FROM ENGAGING END
(8-13PA1 SHOWN)
J
ENTRY
SIZE
7
B
2
REV.
APPROVED
EAG
EAG
MASTER
KEY
DATE
10/09/12
02/12/13
801-069
GLENAIR, INC.
B
THREAD
REVISION HISTORY
DESCRIPTION
PRODUCTION RELEASE
REVISED PER DCN #45302
UNLESS OTHERWISE SPECIFIED DRAWN
CHECK
DIMENSIONS ARE IN INCHES
ENGR
TOLERANCES
E MAX
ASSEMBLED
D MAX
ASSEMBLED
THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN
WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT
WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING
EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC.
S:\part\s8\80\801-0691OF2.prt
1 of 1
KEY POSITION
801-069 -26 ZNU 8-13 P A 1 05
=
=
=
=
PIN, SOLDER
SOCKET, SOLDER
PIN, CRIMP
SOCKET, CRIMP
CABLE ENTRY SIZE (SEE TABLE VI)
1 THROUGH 8 (SEE TABLE IV)
CABLE EXIT DIRECTION
A THROUGH F (SEE TABLE III)
KEY POSITION
A
B
P
S
CONTACT STYLE
(SEE TABLE V)
SHELL SIZE - CONTACT ARRANGEMENT
CLASS (SEE TABLE I)
-26 = SELF-LOCKING PLUG WITH RATCHET
MECHANISM (THE "CLICKER")
SHELL STYLE
CONNECTOR SERIES
EXAMPLE:
PART NUMBER DEVELOPMENT
± 1/16
± 2°
.XXX
.XX
± .015
± .03
B/F 10C5078 P/C
80
DO NOT SCALE THIS DRAWING
ANGLES
DECIMALS
FRACTIONS
G MAX
03/05/12
03/05/12
APPROVED
APPROVED
03/05/12
03/05/12
03/05/12
(DIRECTION 2 SHOWN)
SCALE
N.A.
WEIGHT
N.A.
SHEET
2 OF
801-069
CODE IDENT. NO. SIZE DRAWING NO.
06324 A
PLUG CONNECTOR,
SERIES 801, RATCHETING,
COBRA STYLE
1211 AIR WAY - GLENDALE - CALIFORNIA 91201
B
2
REV.
CABLE EXIT DIRECTION
C°
TABLE VI-CABLE ENTRY
CODE
ENTRY SIZE
02
.125
03
.188
.250
04
05
.313
06
.375
07
.438
08
.500
09
.563
10
.625
11
.688
12
.750
13
.813
.875
14
15
.938
16
1.000
17
1.063
801-069
GLENAIR, INC.
TITLE
JAM NUT RECEPTACLE
MATING SPACE
REQUIREMENT
MASTER
KEY
TABLE IV-EXIT DIRECTION
C°
DIRECTION
1
0°
2
45°
3
90°
4
135°
5
180°
6
225°
7
270°
8
315°
EAG
GSB
EAG
RELEASE DATE
ORIGINAL
RELEASE DATE
UNLESS OTHERWISE SPECIFIED DRAWN
CHECK
DIMENSIONS ARE IN INCHES
ENGR
TOLERANCES
SQUARE FLANGE
RECEPTACLE
MATING SPACE
REQUIREMENT
.060
[1.52]
TABLE V - AVAILABLE ARRANGEMENTS
SHELL SIZE CONTACT ARRANGEMENT*
5
5-3
6-4, 6-6, 6-7
6
7
7-10
8
8-13
9
9-19
10
10-26
11
11-31
13
13-37
16
16-55
17
17-85
19
19-100
21
21-130
*: # FOLLOWING DASH = # OF CONTACTS
H MAX
REVISION HISTORY
SEE SHEET 1 OF 2
H
J
MAX ENTRY
1.23 [31.2] .500 [12.70]
03
1.25 [31.8] .560 [14.22]
04
1.27 [32.3] .650 [16.51]
05
1.28 [32.5] .710 [18.03]
06
1.31 [33.3] .770 [19.56]
07
08
1.35 [34.3] .835 [21.21]
T.B.D.
T.B.D.
09
10
1.63 [41.4] .950 [24.13]
T.B.D.
T.B.D.
12
13
1.78 [45.2] 1.180 [29.97]
T.B.D.
T.B.D.
15
T.B.D.
T.B.D.
17
REAR-MOUNTED
SQUARE FLANGE
RECEPTACLE
G
1.40 [35.6]
1.42 [36.1]
1.44 [36.6]
1.45 [36.8]
1.48 [37.6]
1.52 [38.6]
T.B.D.
1.80 [45.7]
T.B.D.
1.92 [48.8]
T.B.D.
T.B.D.
SHOWN INSTALLED
TABLE II - DIMENSIONAL DATA
F
D
E
.32 [8.1]
1.21 [30.7]
.84 [21.3]
.86 [21.8]
.34 [8.6]
1.24 [31.5]
.88 [22.4]
.39 [9.9]
1.28 [32.5]
.89 [22.6]
.42 [10.7] 1.31 [33.3]
.92 [23.4]
.45 [11.4] 1.34 [34.0]
.96 [24.4]
.48 [12.2] 1.37 [34.8]
T.B.D.
T.B.D.
T.B.D.
1.13 [28.7] .52 [13.2] 1.48 [37.6]
T.B.D.
T.B.D.
T.B.D.
1.28 [32.5] .63 [16.0] 1.78 [45.2]
T.B.D.
T.B.D.
T.B.D.
T.B.D.
T.B.D.
T.B.D.
TABLE III - KEY POSITION
POSITION
A°
B°
A (NORMAL)
150°
210°
B
75°
210°
C
95°
230°
D
275°
140°
E
75°
275°
F
95°
210°
B THREAD
.3125-.05P-.1L-2B
.3750-.05P-.1L-2B
.4375-.05P-.1L-2B
.5000-.05P-.1L-2B
.5625-.05P-.1L-2B
.6250-.05P-.1L-2B
.6875-.05P-.1L-2B
.8125-.1P-.2L-2B
1.0000-.1P-.2L-2B
1.0625-.1P-.2L-2B
1.1875-.1P-.2L-2B
1.3125-.1P-.2L-2B
MASTER
KEY
øA
.65 [16.5]
.65 [16.5]
.69 [17.5]
.79 [20.1]
.83 [21.1]
.92 [23.4]
T.B.D.
1.10 [27.9]
1.34 [34.0]
1.45 [36.8]
1.50 [38.1]
1.65 [41.9]
(POSITION A SHOWN)
B°
A°
SHELL SIZE
5
6
7
8
9
10
11
13
16
17
19
21
THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN
WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT
WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING
EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC.
S:\part\s8\80\801-0692OF2.prt
1 of 1
TABLE I - MATERIAL / FINISH CLASS
SHELL MATERIAL
FINISH
ALUMINUM ALLOY ELECTROLESS NICKEL (RoHS)
ALUMINUM ALLOY NICKEL-PTFE (RoHS)
OLIVE DRAB CADMIUM OVER
ALUMINUM ALLOY
ELECTROLESS NICKEL
BLACK ZINC-NICKEL OVER
ALUMINUM ALLOY
ELECTROLESS NICKEL (RoHS)
STAINLESS STEEL PASSIVATE (RoHS)
UNLESS OTHERWISE SPECIFIED
COVER
9. REAR INSULATOR GROMMET NOT SUPPLIED.
8. THIS CONNECTOR MATES WITH ALL QUICK-DISCONNECT, HIGH DENSITY RECEPTACLE
CONNECTORS WITH SAME POLARIZATION AND OPPOSITE CONTACT GENDER
(804-003 THROUGH 804-006, 804-009, 804-020, AND 804-021).
7. CONTACT ARRANGEMENT, CONTACT GENDER, KEY POSITIONS, AND SHELL
ORIENTATION SHOWN ARE FOR REFERENCE ONLY.
6. CRIMP TOOL DATA:
A. HAND CRIMP TOOL: GLENAIR PART NO. 809-015.
B. POSITIONER FOR HAND TOOL: GLENAIR PART NO. 809-005.
C. INSERTION/EXTRACTION TOOL: GLENAIR PART NO. 809-088.
5. CRIMP BARREL ACCOMMODATES 22, 24, 26, AND 28 GAGE WIRE.
4. CONSULT FACTORY FOR ADDITIONAL CONTACT ARRANGEMENTS AND/OR SHELL
ORIENTATIONS.
3. CONTACTS ARE SIZE 23.
GASKET
REAR INSULATOR
GROMMET NOT
SUPPLIED
2. MATERIAL / FINISH:
PLUG BARREL, HOUSING, COVER - ALUMINUM ALLOY OR
STAINLESS STEEL / SEE TABLE I
INSULATOR - LCP / NONE
INTERFACIAL SEAL, GASKET - FLUOROSILICONE / NONE
CONTACT - COPPER ALLOY / GOLD PLATE PER ASTM B 488, TYPE II,
CODE C, CLASS 1.25 (.00005 MIN THK), OVER A SUITABLE UNDERPLATE
CONTACT RETENTION CLIP - BERYLLIUM COPPER ALLOY / NONE
HARDWARE - STAINLESS STEEL / PASSIVATE OR BLACK OXIDE
1. ASSEMBLY TO BE IDENTIFIED WITH GLENAIR'S NAME, PART NUMBER,
AND DATE CODE, SPACE PERMITTING.
NOTES:
CONTACT GLENAIR FOR ADDITIONAL FINISHES
Z1
ZNU
NF
CLASS
M
MT
± 1/16
± 2°
.XXX
.XX
± .015
± .03
B/F 12C3202 P/C
80
DO NOT SCALE THIS DRAWING
ANGLES
DECIMALS
FRACTIONS
D MAX
ASSEMBLED
REV
A
B
01/18/13
01/18/13
01/18/13
01/18/13
01/18/13
APPROVED
RELEASE DATE
ORIGINAL
RELEASE DATE
APPROVED
EAG
JMT
EAG
.60
[15.2]
MASTER
KEY
SCALE
N.A.
WEIGHT
N.A.
SHEET
1 OF
804-066
CODE IDENT. NO. SIZE DRAWING NO.
06324 A
PLUG CONNECTOR,
SERIES 804,
COBRA STYLE
1211 AIR WAY - GLENDALE - CALIFORNIA 91201
F
B
2
REV.
MAX
B
APPROVED
EAG
EAG
GLENAIR, INC.
TITLE
J
ENTRY
SIZE
A
DATE
01/18/13
02/12/13
804-066
FACE VIEW OF PLUG
AS VIEWED FROM ENGAGING END
(8-13PA1 SHOWN)
7
REVISION HISTORY
DESCRIPTION
PRODUCTION RELEASE
REVISED PER DCN #45302
UNLESS OTHERWISE SPECIFIED DRAWN
CHECK
DIMENSIONS ARE IN INCHES
ENGR
TOLERANCES
E
ASSEMBLED
THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN
WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT
WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING
EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC.
S:\part\s8\80\804-0661OF2.prt
1 of 1
(POSITION A SHOWN)
KEY POSITION
TABLE III - KEY POSITION
A°
POSITION
B°
A (NORMAL)
150°
210°
B
75°
210°
C
95°
230°
D
140°
275°
E
75°
275°
F
95°
210°
=
=
=
=
PIN, SOLDER
SOCKET, SOLDER
PIN, CRIMP
SOCKET, CRIMP
CABLE ENTRY SIZE (SEE TABLE VI)
1 THROUGH 8 (SEE TABLE IV)
CABLE EXIT DIRECTION
A THROUGH F (SEE TABLE III)
OMIT FOR SINGLE MASTER KEY
KEY POSITION
A
B
P
S
CONTACT STYLE
(SEE TABLE V)
SHELL SIZE - CONTACT ARRANGEMENT
± 1/16
± 2°
.XXX
.XX
± .015
± .03
B/F 12C3202 P/C
80
DO NOT SCALE THIS DRAWING
ANGLES
DECIMALS
FRACTIONS
REAR-MOUNTED
RECEPTACLE
MAX ENTRY
03
04
05
06
07
08
10
12
G MAX
01/18/13
01/18/13
01/18/13
01/18/13
01/18/13
APPROVED
RELEASE DATE
ORIGINAL
RELEASE DATE
APPROVED
EAG
JMT
EAG
(DIRECTION 2 SHOWN)
SCALE
N.A.
WEIGHT
N.A.
SHEET
2 OF
804-066
CODE IDENT. NO. SIZE DRAWING NO.
06324 A
PLUG CONNECTOR,
SERIES 804,
COBRA STYLE
1211 AIR WAY - GLENDALE - CALIFORNIA 91201
B
2
REV.
CABLE EXIT DIRECTION
MASTER
KEY
C°
GLENAIR, INC.
TITLE
REAR-MOUNTED
RECEPTACLE
MATING SPACE
REQUIREMENT
TABLE VI-CABLE ENTRY
CODE
ENTRY SIZE
02
.125
03
.188
.250
04
05
.313
06
.375
07
.438
08
.500
09
.563
10
.625
11
.688
12
.750
804-066
TABLE IV-EXIT DIRECTION
DIRECTION
C°
1
0°
2
45°
3
90°
135°
4
5
180°
6
225°
7
270°
8
315°
REVISION HISTORY
SEE SHEET 1 OF 2
SHOWN INSTALLED
UNLESS OTHERWISE SPECIFIED DRAWN
CHECK
DIMENSIONS ARE IN INCHES
ENGR
TOLERANCES
FRONT-MOUNTED
RECEPTACLE
MATING SPACE
REQUIREMENT
TABLE V - AVAILABLE ARRANGEMENTS
SHELL SIZE CONTACT ARRANGEMENT*
5
5-3
6-4, 6-6, 6-7
6
7
7-10
8
8-13
9
9-19
10
10-26
12
12-37
14
14-55
*: # FOLLOWING DASH = # OF CONTACTS
H MAX
J
.500 [12.7]
.560 [14.2]
.650 [16.5]
.710 [18.0]
.770 [19.6]
.835 [21.2]
.950 [24.1]
T.B.D.
.31
([8.0]
)
H
1.16 [29.5]
1.21 [30.7]
1.32 [33.5]
1.36 [34.5]
1.43 [36.3]
1.47 [37.3]
1.56 [39.6]
T.B.D.
FRONT-MOUNTED
RECEPTACLE
G
1.31 [33.4]
1.36 [34.5]
1.47 [37.3]
1.51 [38.4]
1.58 [40.1]
1.62 [41.1]
1.71 [43.4]
T.B.D.
SHOWN INSTALLED
.16
([4.1]
)
TABLE II - DIMENSIONAL DATA
F
D
E
1.03 [26.2]
.29 [7.4]
1.24 [31.5]
.31 [7.9]
1.27 [32.3]
1.08 [27.4]
1.20 [30.5]
.36 [9.1]
1.31 [33.3]
.39 [9.9]
1.24 [31.5]
1.34 [34.0]
1.30 [33.0] .42 [10.7] 1.37 [34.8]
1.35 [34.3] .45 [11.4] 1.40 [35.6]
1.44 [36.6] .49 [12.4] 1.51 [38.4]
T.B.D.
T.B.D.
T.B.D.
804-066 -06 ZNU 8-13 P A 1 05
CLASS (SEE TABLE I)
-06 = PLUG
SHELL STYLE
CONNECTOR SERIES
EXAMPLE:
B
.27 [6.9]
.30 [7.6]
.34 [8.6]
.38 [9.7]
.41 [10.4]
.44 [11.2]
.50 [12.7]
T.B.D.
MASTER
KEY
øA
.67 [17.0]
.75 [19.1]
.88 [22.4]
.97 [24.6]
1.06 [26.9]
1.15 [29.2]
1.33 [33.8]
T.B.D.
PART NUMBER DEVELOPMENT
B°
A°
SHELL SIZE
5
6
7
8
9
10
12
14
THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN
WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT
WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING
EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC.
S:\part\s8\80\804-0662OF2.prt
1 of 1
TABLE I - MATERIAL / FINISH CLASS
SHELL MATERIAL
FINISH
ALUMINUM ALLOY ELECTROLESS NICKEL (RoHS)
ALUMINUM ALLOY NICKEL-PTFE (RoHS)
OLIVE DRAB CADMIUM OVER
ALUMINUM ALLOY
ELECTROLESS NICKEL
BLACK ZINC-NICKEL OVER
ALUMINUM ALLOY
ELECTROLESS NICKEL (RoHS)
STAINLESS STEEL PASSIVATE (RoHS)
UNLESS OTHERWISE SPECIFIED
COVER
9. REAR INSULATOR GROMMET NOT SUPPLIED.
8. THIS CONNECTOR MATES WITH ALL QUICK COUPLING, HIGH DENSITY RECEPTACLE
CONNECTORS WITH SAME POLARIZATION AND OPPOSITE CONTACT GENDER
(805-003 THROUGH 805-006 AND 805-017).
7. CONTACT ARRANGEMENT, CONTACT GENDER, KEY POSITIONS, AND SHELL
ORIENTATION SHOWN ARE FOR REFERENCE ONLY.
6. CRIMP TOOL DATA:
A. HAND CRIMP TOOL: GLENAIR PART NO. 809-015.
B. POSITIONER FOR HAND TOOL: GLENAIR PART NO. 809-005.
C. INSERTION/EXTRACTION TOOL: GLENAIR PART NO. 809-088.
5. CRIMP BARREL ACCOMMODATES 22, 24, 26, AND 28 GAGE WIRE.
4. CONSULT FACTORY FOR ADDITIONAL CONTACT ARRANGEMENTS AND/OR SHELL
ORIENTATIONS.
3. CONTACTS ARE SIZE 23.
GASKET
REAR INSULATOR
GROMMET NOT
SUPPLIED
2. MATERIAL / FINISH:
PLUG BARREL, COUPLING NUT, HOUSING, COVER - ALUMINUM
ALLOY OR STAINLESS STEEL / SEE TABLE I
INSULATOR - LCP / NONE.
INTERFACIAL SEAL, GASKET - FLUOROSILICONE / NONE
CONTACT - COPPER ALLOY / GOLD PLATE PER ASTM B 488, TYPE II,
CODE C, CLASS 1.25 (.00005 MIN THK), OVER A SUITABLE UNDERPLATE
CONTACT RETENTION CLIP - BERYLLIUM COPPER ALLOY / NONE
HARDWARE - STAINLESS STEEL / PASSIVATE OR BLACK OXIDE
RETAINING WIRE - TORLON / NONE
DETENT SPRING, RIVET - STAINLESS STEEL / PASSIVATE
EMI GROUND SPRING - BERYLLIUM COPPER / ELECTROLESS NICKEL
1. ASSEMBLY TO BE IDENTIFIED WITH GLENAIR'S NAME, PART NUMBER,
AND DATE CODE, SPACE PERMITTING.
NOTES:
CONTACT GLENAIR FOR ADDITIONAL FINISHES
Z1
ZNU
NF
CLASS
M
MT
± 1/16
± 2°
.XXX
.XX
± .015
± .03
B/F 11C8797 P/C
80
DO NOT SCALE THIS DRAWING
ANGLES
DECIMALS
FRACTIONS
D MAX
ASSEMBLED
REV
A
B
07/19/12
07/19/12
07/19/12
07/18/12
07/18/12
APPROVED
RELEASE DATE
ORIGINAL
RELEASE DATE
APPROVED
EAG
GSB
EAG
1
MASTER
KEY
SCALE
N.A.
WEIGHT
N.A.
SHEET
1 OF
805-061
CODE IDENT. NO. SIZE DRAWING NO.
06324 A
PLUG CONNECTOR,
SERIES 805 STYLE
RATCHETING COBRA
1211 AIR WAY - GLENDALE - CALIFORNIA 91201
B
2
REV.
F
7
APPROVED
EAG
EAG
FACE VIEW OF PLUG
AS VIEWED FROM ENGAGING END
(10-13PA1 SHOWN)
J
ENTRY
SIZE
DATE
07/19/12
02/12/13
805-061
GLENAIR, INC.
TITLE
øA
B
THREAD
REVISION HISTORY
DESCRIPTION
PRODUCTION RELEASE
REVISED PER DCN #45302
UNLESS OTHERWISE SPECIFIED DRAWN
CHECK
DIMENSIONS ARE IN INCHES
ENGR
TOLERANCES
E MAX
ASSEMBLED
THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN
WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT
WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING
EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC.
S:\part\s8\80\805-0611OF2.prt
1 of 1
(POSITION A SHOWN)
KEY POSITION
805-061 -16 ZNU 9-10 P A 1 05
=
=
=
=
PIN, SOLDER
SOCKET, SOLDER
PIN, CRIMP
SOCKET, CRIMP
CABLE ENTRY SIZE (SEE TABLE VI)
1 THROUGH 8 (SEE TABLE IV)
CABLE EXIT DIRECTION
A THROUGH F (SEE TABLE III)
KEY POSITION
A
B
P
S
CONTACT STYLE
(SEE TABLE V)
SHELL SIZE - CONTACT ARRANGEMENT
CLASS (SEE TABLE I)
-16 = PLUG CONNECTOR WITH RATCHETING
ANTI-DECOUPLING MECHANISM
SHELL STYLE
CONNECTOR SERIES
EXAMPLE:
± 1/16
± 2°
.XXX
.XX
± .015
± .03
B/F 11C8797 P/C
80
DO NOT SCALE THIS DRAWING
ANGLES
DECIMALS
FRACTIONS
G MAX
MASTER
KEY
(DIRECTION 2 SHOWN)
SCALE
N.A.
WEIGHT
N.A.
SHEET
2 OF
805-061
CODE IDENT. NO. SIZE DRAWING NO.
06324 A
PLUG CONNECTOR,
SERIES 805 STYLE
RATCHETING COBRA
1211 AIR WAY - GLENDALE - CALIFORNIA 91201
GLENAIR, INC.
TITLE
C°
TABLE VI-CABLE ENTRY
CODE
ENTRY SIZE
02
.125
03
.188
.250
04
05
.313
06
.375
07
.438
08
.500
09
.563
10
.625
11
.688
12
.750
13
.813
.875
14
15
.938
16
1.000
17
1.063
805-061
B
2
REV.
CABLE EXIT DIRECTION
JAM NUT RECEPTACLE
MATING SPACE
REQUIREMENT
07/19/12
07/19/12
07/19/12
07/18/12
07/18/12
APPROVED
APPROVED
EAG
GSB
EAG
RELEASE DATE
ORIGINAL
RELEASE DATE
UNLESS OTHERWISE SPECIFIED DRAWN
CHECK
DIMENSIONS ARE IN INCHES
ENGR
TOLERANCES
SQUARE FLANGE
RECEPTACLE
MATING SPACE
REQUIREMENT
.060
[1.52]
TABLE V - AVAILABLE ARRANGEMENTS
SHELL SIZE CONTACT ARRANGEMENT*
8-4, 8-6, 8-7
8
9
9-10
10
10-13
11
11-19
12
12-26
13
13-31
15
15-37
18
18-55
19
19-85
21
21-100
23
23-130
*: # FOLLOWING DASH = # OF CONTACTS
H MAX
J
MAX ENTRY
.560 [14.22]
04
.650 [16.51]
05
.710 [18.03]
06
.770 [19.56]
07
.835 [21.21]
08
T.B.D.
09
10
.950 [24.13]
T.B.D.
12
1.180 [29.97]
13
T.B.D.
15
T.B.D.
17
REVISION HISTORY
SEE SHEET 1 OF 2
TABLE IV-EXIT DIRECTION
DIRECTION
C°
1
0°
2
45°
3
90°
4
135°
5
180°
225°
6
7
270°
8
315°
H
1.62 [41.1]
1.63 [41.4]
1.65 [41.9]
1.68 [42.7]
1.71 [43.4]
T.B.D.
1.77 [45.0]
T.B.D.
1.92 [48.8]
T.B.D.
T.B.D.
REAR-MOUNTED
SQUARE FLANGE
RECEPTACLE
G
1.76 [44.7]
1.77 [45.0]
1.79 [45.5]
1.82 [46.2]
1.85 [47.0]
T.B.D.
1.91 [48.5]
T.B.D.
2.06 [52.3]
T.B.D.
T.B.D.
SHOWN INSTALLED
TABLE II - DIMENSIONAL DATA
F
D
E
1.02 [25.9]
.34 [8.6]
1.24 [31.5]
1.03 [26.2]
.39 [9.9]
1.28 [32.5]
1.05 [26.7] .42 [10.7] 1.31 [33.3]
1.08 [27.4] .45 [11.4] 1.34 [34.0]
1.11 [28.2] .48 [12.2] 1.37 [34.8]
T.B.D.
T.B.D.
T.B.D.
1.17 [29.7] .52 [13.2] 1.48 [37.6]
T.B.D.
T.B.D.
T.B.D.
1.32 [33.5] .63 [16.0] 1.78 [45.2]
T.B.D.
T.B.D.
T.B.D.
T.B.D.
T.B.D.
T.B.D.
TABLE III - KEY POSITION
POSITION
A°
B°
A (NORMAL)
150°
210°
B
75°
210°
C
95°
230°
D
275°
140°
E
75°
275°
F
95°
210°
B THREAD
.5000-.1P-.3L-TS-2B
.5625-.1P-.3L-TS-2B
.6250-.1P-.3L-TS-2B
.6875-.1P-.3L-TS-2B
.7500-.1P-.3L-TS-2B
.8125-.1P-.3L-TS-2B
.9375-.1P-.3L-TS-2B
1.1250-.1P-.3L-TS-2B
1.1875-.1P-.3L-TS-2B
1.3125-.1P-.3L-TS-2B
1.4375-.1P-.3L-TS-2B
MASTER
KEY
øA
.65 [15.7]
.79 [20.1]
.83 [21.1]
.92 [23.4]
.98 [24.9]
1.05 [26.7]
1.10 [27.9]
1.29 [32.8]
1.31 [33.3]
1.45 [36.8]
1.56 [39.6]
PART NUMBER DEVELOPMENT
B°
A°
SHELL SIZE
8
9
10
11
12
13
15
18
19
21
23
THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN
WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT
WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING
EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC.
S:\part\s8\80\805-0612OF2.prt
1 of 1

Similar documents

Amphenol

Amphenol To avoid cross-plugging problems in applications requiring the use of more than one connector of the same size and arrangement, alternate rotations are available as indicated in the chart below. As...

More information

Solderless Terminals, Terminal Blocks and Connectors

Solderless Terminals, Terminal Blocks and Connectors Braid: Woven bare metallic or tinned copper wire used as shielding for wires and cables and as ground wire for batteries or heavy industrial equipment. Also a woven fibrous protective outer coverin...

More information

AMPSEAL 16 Connector System

AMPSEAL 16 Connector System silicone seals allow the connectors to withstand extreme temperatures and moisture.

More information