Mighty Mouse Cobra
Transcription
Mighty Mouse Cobra
MIGHTY MOUSE Cobra The Ultra-Low Profile EMI/RFI Plug and Backshell Assembly I nnovative shielded low profile right angle connector plug and backshell assemblies reduce clearance requirements without compromising ruggedness or shielding performance. Available in Series 801 double-start, Series 804 QDC push-pull, and Series 805 triple-start, Cobra assemblies provide optimal low-profile cable routing and legendary Mighty Mouse connector performance in a single package. Each Cobra assembly is equipped with a removable rear cover and gasket for easy crimp or solder contact termination of the connector. Both pin and socket versions are available for both crimp and solder terminated versions. Integrated lowprofile backshell is equipped with an EMI/RFI shield termination platform and a shrink boot lip. The ultra-lightweight assembly may be clocked in eight different angle orientations for additional flexibility in cable routing. Connectors are equipped with polarization keying to prevent mismating. Glenair Mighty Mouse Cobra connector and backshell assemblies mate with available square flange and jam nut receptacles from each respective connector series. Fourteen contact arrangements are available, all with Size #23 contacts from shell size 5 to shell size 21 with 3-130 contacts respectively. Connector shells are aluminum alloy or stainless steel. Space-saving design features one-piece machined and brazed connector shell and right angle backshell for minimum height and optimal EMI performance. Master key clocking enables easy cable entry/ exit routing in eight angles Removable rear cover and gasket provides easy access to end of connector for crimp or solder contact termination For more information contact Glenair at 818-247-6000 or visit our website at www.glenair.com MIGHTY MOUSE 805-061 triple-start with self-locking coupling nut, exploded view Cobra T E C H N I C A L S P E C I F I C AT I O N S B Thread How To Order Mighty Mouse Cobra Plug Connector and Backshell Assemblies 801-069-26 Sample Part Number ZNU Connector Series and Mighty Mouse Cobra Basic Part Number 801-069-26 Double-Start self-locking plug with ratchet mechanism (the clicker) 804-066-06 QDC Push-Pull plug 805-061-16 Triple-Start plug with ratcheting anti-decoupling mechanism Material/Finish M, MT, NF, ZNU, Z1 - See Table I 8-13 P A 1 Master Key 05 F Shell Size - Contact Arrangement See Table V - A: 801-069 B: 804-066 C: 805-061 Contact Style A = Pin, solder B = Socket, solder P = Pin, Crimp S = Socket, crimp Polarization Key Position A, B, C, D, E, F - See Table III Cable Exit Direction 1, 2, 3, 4, 5, 6, 7, 8 - See Table IV Cable Entry Size See Table VI Specifications • • • • • • • • • • Current Rating: #23 5 Amps Test Voltage (DWV) #23: 500 VAC Sea Level Insulation Resistance: 5000 megohms minimum Contact Resistance: 73 millivolt drop at 5 Amp test current Mating Cycles Series 801 and 804: 2000; Series 805: 500 Operating Temperature: -55° C. to +150° C. Shielding Effectiveness: 50 dB min from 100MHz to 1000MHz. Magnetic Permeability: 2.0µ Vibration: 37g / Shock: 300g Immersion, mated: 1meter water immersion for 1 hour Materials/finish • • • • • Contacts: Copper alloy, gold plated Backshell Housing and Lid: Aluminum or Stainless Steel Backshell Sealing Gasket and Interfacial Seal: Fluorosilicone Screws: 300 Series Stainless Steel Insulator: LCP Notes • Rear insulator grommet not supplied. • Cobra plug connectors mate with respective series receptacles with same polarization and opposite contact gender. • Hand crimp tool: P/N 809-015. Positioner for hand tool: P/N 809-005. Insertion/extraction tool P/N 809-088. • Crimp barrel accommodates 22, 24, 26 and 28 gage wire. • All Cobra plugs equipped with Size #23 contacts. Symbol M NF MT ZNU Z1 Table I: Shell Material/Finish Finish Electroless Nickel (RoHS) Aluminum Cad/O.D. over Electroless Nickel Alloy Nickel-PTFE (RoHS) Black Zinc Nickel over Electroless Nickel Stainless Passivate Steel Material ØC J Table III: Key Positions Table IV: Exit Direction Direction C° 1 0° 2 45° 3 90° 4 135° 5 180° 6 225° 7 270° 8 315° C° Table VI - Cable Entry Code Entry Size 02 .125 03 .188 04 .250 B° A° 05 .313 06 .375 07 .438 08 .500 09 .563 A° B° 10 .625 A 150° 210° 11 .688 Master B 75° 210° 12 .750 Key C 95° 230° 13* .813 D 140° 275° 14* .875 E 75° 275° 15* .938 F 95° 210° 16* 1.000 17* 1.063 Direction 2 Shown * Entry codes 13-17 not available for Series 804 Cobra Table V - Shell Size/Contact Arrangements A: 801-069 B: 804-066 C: 805-061 Shell Contact Max Shell Contact Max Shell Contact Max Size Arrangement Entry Size Arrangement Entry Size Arrangement Entry 5 5-3 03 5 5-3 03 8 8-4, 8-6, 8-7 04 6 6-4, 6-6, 6-7 04 6 6-4, 6-6, 6-7 04 9 9-10 05 7 7-10 05 7 7-10 05 10 10-13 06 8 8-13 06 8 8-13 06 11 11-19 07 9 9-19 07 9 9-19 07 12 12-26 08 10 10-26 08 10 10-26 08 13 13-31 09 11 11-31 09 12 12-37 10 15 15-37 10 13 13-37 10 14 14-55 12 18 18-55 12 16 16-55 12 19 19-85 13 17 17-85 13 21 21-100 15 19 19-100 15 23 23-130 17 21 21-130 17 TABLE I - MATERIAL / FINISH CLASS SHELL MATERIAL FINISH ALUMINUM ALLOY ELECTROLESS NICKEL (RoHS) ALUMINUM ALLOY NICKEL-PTFE (RoHS) OLIVE DRAB CADMIUM OVER ALUMINUM ALLOY ELECTROLESS NICKEL BLACK ZINC-NICKEL OVER ALUMINUM ALLOY ELECTROLESS NICKEL (RoHS) STAINLESS STEEL PASSIVATE (RoHS) UNLESS OTHERWISE SPECIFIED COVER 9. REAR INSULATOR GROMMET NOT SUPPLIED. 8. THIS CONNECTOR MATES WITH ALL QUICK COUPLING, HIGH DENSITY RECEPTACLE CONNECTORS WITH SAME POLARIZATION AND OPPOSITE CONTACT GENDER (801-003 THROUGH 801-006 AND 801-009 THROUGH 801-012). 7. CONTACT ARRANGEMENT, CONTACT GENDER, KEY POSITIONS, AND SHELL ORIENTATION SHOWN ARE FOR REFERENCE ONLY. 6. CRIMP TOOL DATA: A. HAND CRIMP TOOL: GLENAIR PART NO. 809-015. B. POSITIONER FOR HAND TOOL: GLENAIR PART NO. 809-005. C. INSERTION/EXTRACTION TOOL: GLENAIR PART NO. 809-088. 5. CRIMP BARREL ACCOMMODATES 22, 24, 26, AND 28 GAGE WIRE. 4. CONSULT FACTORY FOR ADDITIONAL CONTACT ARRANGEMENTS AND/OR SHELL ORIENTATIONS. 3. CONTACTS ARE SIZE 23. GASKET REAR INSULATOR GROMMET NOT SUPPLIED 2. MATERIAL / FINISH: PLUG BARREL, COUPLING NUT, HOUSING, COVER - ALUMINUM ALLOY OR STAINLESS STEEL / SEE TABLE I INSULATOR - LCP / NONE INTERFACIAL SEAL, GASKET - FLUOROSILICONE / NONE CONTACT - COPPER ALLOY / GOLD PLATE PER ASTM B 488, TYPE II, CODE C, CLASS 1.25 (.00005 MIN THK), OVER A SUITABLE UNDERPLATE CONTACT RETENTION CLIP - BERYLLIUM COPPER ALLOY / NONE HARDWARE - STAINLESS STEEL / PASSIVATE OR BLACK OXIDE RETAINING WIRE - TORLON / NONE DETENT SPRING / RIVET - STAINLESS STEEL / PASSIVATE 1. ASSEMBLY TO BE IDENTIFIED WITH GLENAIR'S NAME, PART NUMBER, AND DATE CODE, SPACE PERMITTING. NOTES: CONTACT GLENAIR FOR ADDITIONAL FINISHES Z1 ZNU NF CLASS M MT REV A B ± 1/16 ± 2° .XXX .XX ± .015 ± .03 B/F 10C5078 P/C 80 DO NOT SCALE THIS DRAWING ANGLES DECIMALS FRACTIONS 03/05/12 03/05/12 03/05/12 øA 03/05/12 03/05/12 APPROVED RELEASE DATE ORIGINAL RELEASE DATE APPROVED EAG GSB EAG 1 SCALE N.A. WEIGHT N.A. SHEET 1 OF 801-069 CODE IDENT. NO. SIZE DRAWING NO. 06324 A PLUG CONNECTOR, SERIES 801, RATCHETING, COBRA STYLE F 1211 AIR WAY - GLENDALE - CALIFORNIA 91201 TITLE FACE VIEW OF PLUG AS VIEWED FROM ENGAGING END (8-13PA1 SHOWN) J ENTRY SIZE 7 B 2 REV. APPROVED EAG EAG MASTER KEY DATE 10/09/12 02/12/13 801-069 GLENAIR, INC. B THREAD REVISION HISTORY DESCRIPTION PRODUCTION RELEASE REVISED PER DCN #45302 UNLESS OTHERWISE SPECIFIED DRAWN CHECK DIMENSIONS ARE IN INCHES ENGR TOLERANCES E MAX ASSEMBLED D MAX ASSEMBLED THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC. S:\part\s8\80\801-0691OF2.prt 1 of 1 KEY POSITION 801-069 -26 ZNU 8-13 P A 1 05 = = = = PIN, SOLDER SOCKET, SOLDER PIN, CRIMP SOCKET, CRIMP CABLE ENTRY SIZE (SEE TABLE VI) 1 THROUGH 8 (SEE TABLE IV) CABLE EXIT DIRECTION A THROUGH F (SEE TABLE III) KEY POSITION A B P S CONTACT STYLE (SEE TABLE V) SHELL SIZE - CONTACT ARRANGEMENT CLASS (SEE TABLE I) -26 = SELF-LOCKING PLUG WITH RATCHET MECHANISM (THE "CLICKER") SHELL STYLE CONNECTOR SERIES EXAMPLE: PART NUMBER DEVELOPMENT ± 1/16 ± 2° .XXX .XX ± .015 ± .03 B/F 10C5078 P/C 80 DO NOT SCALE THIS DRAWING ANGLES DECIMALS FRACTIONS G MAX 03/05/12 03/05/12 APPROVED APPROVED 03/05/12 03/05/12 03/05/12 (DIRECTION 2 SHOWN) SCALE N.A. WEIGHT N.A. SHEET 2 OF 801-069 CODE IDENT. NO. SIZE DRAWING NO. 06324 A PLUG CONNECTOR, SERIES 801, RATCHETING, COBRA STYLE 1211 AIR WAY - GLENDALE - CALIFORNIA 91201 B 2 REV. CABLE EXIT DIRECTION C° TABLE VI-CABLE ENTRY CODE ENTRY SIZE 02 .125 03 .188 .250 04 05 .313 06 .375 07 .438 08 .500 09 .563 10 .625 11 .688 12 .750 13 .813 .875 14 15 .938 16 1.000 17 1.063 801-069 GLENAIR, INC. TITLE JAM NUT RECEPTACLE MATING SPACE REQUIREMENT MASTER KEY TABLE IV-EXIT DIRECTION C° DIRECTION 1 0° 2 45° 3 90° 4 135° 5 180° 6 225° 7 270° 8 315° EAG GSB EAG RELEASE DATE ORIGINAL RELEASE DATE UNLESS OTHERWISE SPECIFIED DRAWN CHECK DIMENSIONS ARE IN INCHES ENGR TOLERANCES SQUARE FLANGE RECEPTACLE MATING SPACE REQUIREMENT .060 [1.52] TABLE V - AVAILABLE ARRANGEMENTS SHELL SIZE CONTACT ARRANGEMENT* 5 5-3 6-4, 6-6, 6-7 6 7 7-10 8 8-13 9 9-19 10 10-26 11 11-31 13 13-37 16 16-55 17 17-85 19 19-100 21 21-130 *: # FOLLOWING DASH = # OF CONTACTS H MAX REVISION HISTORY SEE SHEET 1 OF 2 H J MAX ENTRY 1.23 [31.2] .500 [12.70] 03 1.25 [31.8] .560 [14.22] 04 1.27 [32.3] .650 [16.51] 05 1.28 [32.5] .710 [18.03] 06 1.31 [33.3] .770 [19.56] 07 08 1.35 [34.3] .835 [21.21] T.B.D. T.B.D. 09 10 1.63 [41.4] .950 [24.13] T.B.D. T.B.D. 12 13 1.78 [45.2] 1.180 [29.97] T.B.D. T.B.D. 15 T.B.D. T.B.D. 17 REAR-MOUNTED SQUARE FLANGE RECEPTACLE G 1.40 [35.6] 1.42 [36.1] 1.44 [36.6] 1.45 [36.8] 1.48 [37.6] 1.52 [38.6] T.B.D. 1.80 [45.7] T.B.D. 1.92 [48.8] T.B.D. T.B.D. SHOWN INSTALLED TABLE II - DIMENSIONAL DATA F D E .32 [8.1] 1.21 [30.7] .84 [21.3] .86 [21.8] .34 [8.6] 1.24 [31.5] .88 [22.4] .39 [9.9] 1.28 [32.5] .89 [22.6] .42 [10.7] 1.31 [33.3] .92 [23.4] .45 [11.4] 1.34 [34.0] .96 [24.4] .48 [12.2] 1.37 [34.8] T.B.D. T.B.D. T.B.D. 1.13 [28.7] .52 [13.2] 1.48 [37.6] T.B.D. T.B.D. T.B.D. 1.28 [32.5] .63 [16.0] 1.78 [45.2] T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. TABLE III - KEY POSITION POSITION A° B° A (NORMAL) 150° 210° B 75° 210° C 95° 230° D 275° 140° E 75° 275° F 95° 210° B THREAD .3125-.05P-.1L-2B .3750-.05P-.1L-2B .4375-.05P-.1L-2B .5000-.05P-.1L-2B .5625-.05P-.1L-2B .6250-.05P-.1L-2B .6875-.05P-.1L-2B .8125-.1P-.2L-2B 1.0000-.1P-.2L-2B 1.0625-.1P-.2L-2B 1.1875-.1P-.2L-2B 1.3125-.1P-.2L-2B MASTER KEY øA .65 [16.5] .65 [16.5] .69 [17.5] .79 [20.1] .83 [21.1] .92 [23.4] T.B.D. 1.10 [27.9] 1.34 [34.0] 1.45 [36.8] 1.50 [38.1] 1.65 [41.9] (POSITION A SHOWN) B° A° SHELL SIZE 5 6 7 8 9 10 11 13 16 17 19 21 THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC. S:\part\s8\80\801-0692OF2.prt 1 of 1 TABLE I - MATERIAL / FINISH CLASS SHELL MATERIAL FINISH ALUMINUM ALLOY ELECTROLESS NICKEL (RoHS) ALUMINUM ALLOY NICKEL-PTFE (RoHS) OLIVE DRAB CADMIUM OVER ALUMINUM ALLOY ELECTROLESS NICKEL BLACK ZINC-NICKEL OVER ALUMINUM ALLOY ELECTROLESS NICKEL (RoHS) STAINLESS STEEL PASSIVATE (RoHS) UNLESS OTHERWISE SPECIFIED COVER 9. REAR INSULATOR GROMMET NOT SUPPLIED. 8. THIS CONNECTOR MATES WITH ALL QUICK-DISCONNECT, HIGH DENSITY RECEPTACLE CONNECTORS WITH SAME POLARIZATION AND OPPOSITE CONTACT GENDER (804-003 THROUGH 804-006, 804-009, 804-020, AND 804-021). 7. CONTACT ARRANGEMENT, CONTACT GENDER, KEY POSITIONS, AND SHELL ORIENTATION SHOWN ARE FOR REFERENCE ONLY. 6. CRIMP TOOL DATA: A. HAND CRIMP TOOL: GLENAIR PART NO. 809-015. B. POSITIONER FOR HAND TOOL: GLENAIR PART NO. 809-005. C. INSERTION/EXTRACTION TOOL: GLENAIR PART NO. 809-088. 5. CRIMP BARREL ACCOMMODATES 22, 24, 26, AND 28 GAGE WIRE. 4. CONSULT FACTORY FOR ADDITIONAL CONTACT ARRANGEMENTS AND/OR SHELL ORIENTATIONS. 3. CONTACTS ARE SIZE 23. GASKET REAR INSULATOR GROMMET NOT SUPPLIED 2. MATERIAL / FINISH: PLUG BARREL, HOUSING, COVER - ALUMINUM ALLOY OR STAINLESS STEEL / SEE TABLE I INSULATOR - LCP / NONE INTERFACIAL SEAL, GASKET - FLUOROSILICONE / NONE CONTACT - COPPER ALLOY / GOLD PLATE PER ASTM B 488, TYPE II, CODE C, CLASS 1.25 (.00005 MIN THK), OVER A SUITABLE UNDERPLATE CONTACT RETENTION CLIP - BERYLLIUM COPPER ALLOY / NONE HARDWARE - STAINLESS STEEL / PASSIVATE OR BLACK OXIDE 1. ASSEMBLY TO BE IDENTIFIED WITH GLENAIR'S NAME, PART NUMBER, AND DATE CODE, SPACE PERMITTING. NOTES: CONTACT GLENAIR FOR ADDITIONAL FINISHES Z1 ZNU NF CLASS M MT ± 1/16 ± 2° .XXX .XX ± .015 ± .03 B/F 12C3202 P/C 80 DO NOT SCALE THIS DRAWING ANGLES DECIMALS FRACTIONS D MAX ASSEMBLED REV A B 01/18/13 01/18/13 01/18/13 01/18/13 01/18/13 APPROVED RELEASE DATE ORIGINAL RELEASE DATE APPROVED EAG JMT EAG .60 [15.2] MASTER KEY SCALE N.A. WEIGHT N.A. SHEET 1 OF 804-066 CODE IDENT. NO. SIZE DRAWING NO. 06324 A PLUG CONNECTOR, SERIES 804, COBRA STYLE 1211 AIR WAY - GLENDALE - CALIFORNIA 91201 F B 2 REV. MAX B APPROVED EAG EAG GLENAIR, INC. TITLE J ENTRY SIZE A DATE 01/18/13 02/12/13 804-066 FACE VIEW OF PLUG AS VIEWED FROM ENGAGING END (8-13PA1 SHOWN) 7 REVISION HISTORY DESCRIPTION PRODUCTION RELEASE REVISED PER DCN #45302 UNLESS OTHERWISE SPECIFIED DRAWN CHECK DIMENSIONS ARE IN INCHES ENGR TOLERANCES E ASSEMBLED THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC. S:\part\s8\80\804-0661OF2.prt 1 of 1 (POSITION A SHOWN) KEY POSITION TABLE III - KEY POSITION A° POSITION B° A (NORMAL) 150° 210° B 75° 210° C 95° 230° D 140° 275° E 75° 275° F 95° 210° = = = = PIN, SOLDER SOCKET, SOLDER PIN, CRIMP SOCKET, CRIMP CABLE ENTRY SIZE (SEE TABLE VI) 1 THROUGH 8 (SEE TABLE IV) CABLE EXIT DIRECTION A THROUGH F (SEE TABLE III) OMIT FOR SINGLE MASTER KEY KEY POSITION A B P S CONTACT STYLE (SEE TABLE V) SHELL SIZE - CONTACT ARRANGEMENT ± 1/16 ± 2° .XXX .XX ± .015 ± .03 B/F 12C3202 P/C 80 DO NOT SCALE THIS DRAWING ANGLES DECIMALS FRACTIONS REAR-MOUNTED RECEPTACLE MAX ENTRY 03 04 05 06 07 08 10 12 G MAX 01/18/13 01/18/13 01/18/13 01/18/13 01/18/13 APPROVED RELEASE DATE ORIGINAL RELEASE DATE APPROVED EAG JMT EAG (DIRECTION 2 SHOWN) SCALE N.A. WEIGHT N.A. SHEET 2 OF 804-066 CODE IDENT. NO. SIZE DRAWING NO. 06324 A PLUG CONNECTOR, SERIES 804, COBRA STYLE 1211 AIR WAY - GLENDALE - CALIFORNIA 91201 B 2 REV. CABLE EXIT DIRECTION MASTER KEY C° GLENAIR, INC. TITLE REAR-MOUNTED RECEPTACLE MATING SPACE REQUIREMENT TABLE VI-CABLE ENTRY CODE ENTRY SIZE 02 .125 03 .188 .250 04 05 .313 06 .375 07 .438 08 .500 09 .563 10 .625 11 .688 12 .750 804-066 TABLE IV-EXIT DIRECTION DIRECTION C° 1 0° 2 45° 3 90° 135° 4 5 180° 6 225° 7 270° 8 315° REVISION HISTORY SEE SHEET 1 OF 2 SHOWN INSTALLED UNLESS OTHERWISE SPECIFIED DRAWN CHECK DIMENSIONS ARE IN INCHES ENGR TOLERANCES FRONT-MOUNTED RECEPTACLE MATING SPACE REQUIREMENT TABLE V - AVAILABLE ARRANGEMENTS SHELL SIZE CONTACT ARRANGEMENT* 5 5-3 6-4, 6-6, 6-7 6 7 7-10 8 8-13 9 9-19 10 10-26 12 12-37 14 14-55 *: # FOLLOWING DASH = # OF CONTACTS H MAX J .500 [12.7] .560 [14.2] .650 [16.5] .710 [18.0] .770 [19.6] .835 [21.2] .950 [24.1] T.B.D. .31 ([8.0] ) H 1.16 [29.5] 1.21 [30.7] 1.32 [33.5] 1.36 [34.5] 1.43 [36.3] 1.47 [37.3] 1.56 [39.6] T.B.D. FRONT-MOUNTED RECEPTACLE G 1.31 [33.4] 1.36 [34.5] 1.47 [37.3] 1.51 [38.4] 1.58 [40.1] 1.62 [41.1] 1.71 [43.4] T.B.D. SHOWN INSTALLED .16 ([4.1] ) TABLE II - DIMENSIONAL DATA F D E 1.03 [26.2] .29 [7.4] 1.24 [31.5] .31 [7.9] 1.27 [32.3] 1.08 [27.4] 1.20 [30.5] .36 [9.1] 1.31 [33.3] .39 [9.9] 1.24 [31.5] 1.34 [34.0] 1.30 [33.0] .42 [10.7] 1.37 [34.8] 1.35 [34.3] .45 [11.4] 1.40 [35.6] 1.44 [36.6] .49 [12.4] 1.51 [38.4] T.B.D. T.B.D. T.B.D. 804-066 -06 ZNU 8-13 P A 1 05 CLASS (SEE TABLE I) -06 = PLUG SHELL STYLE CONNECTOR SERIES EXAMPLE: B .27 [6.9] .30 [7.6] .34 [8.6] .38 [9.7] .41 [10.4] .44 [11.2] .50 [12.7] T.B.D. MASTER KEY øA .67 [17.0] .75 [19.1] .88 [22.4] .97 [24.6] 1.06 [26.9] 1.15 [29.2] 1.33 [33.8] T.B.D. PART NUMBER DEVELOPMENT B° A° SHELL SIZE 5 6 7 8 9 10 12 14 THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC. S:\part\s8\80\804-0662OF2.prt 1 of 1 TABLE I - MATERIAL / FINISH CLASS SHELL MATERIAL FINISH ALUMINUM ALLOY ELECTROLESS NICKEL (RoHS) ALUMINUM ALLOY NICKEL-PTFE (RoHS) OLIVE DRAB CADMIUM OVER ALUMINUM ALLOY ELECTROLESS NICKEL BLACK ZINC-NICKEL OVER ALUMINUM ALLOY ELECTROLESS NICKEL (RoHS) STAINLESS STEEL PASSIVATE (RoHS) UNLESS OTHERWISE SPECIFIED COVER 9. REAR INSULATOR GROMMET NOT SUPPLIED. 8. THIS CONNECTOR MATES WITH ALL QUICK COUPLING, HIGH DENSITY RECEPTACLE CONNECTORS WITH SAME POLARIZATION AND OPPOSITE CONTACT GENDER (805-003 THROUGH 805-006 AND 805-017). 7. CONTACT ARRANGEMENT, CONTACT GENDER, KEY POSITIONS, AND SHELL ORIENTATION SHOWN ARE FOR REFERENCE ONLY. 6. CRIMP TOOL DATA: A. HAND CRIMP TOOL: GLENAIR PART NO. 809-015. B. POSITIONER FOR HAND TOOL: GLENAIR PART NO. 809-005. C. INSERTION/EXTRACTION TOOL: GLENAIR PART NO. 809-088. 5. CRIMP BARREL ACCOMMODATES 22, 24, 26, AND 28 GAGE WIRE. 4. CONSULT FACTORY FOR ADDITIONAL CONTACT ARRANGEMENTS AND/OR SHELL ORIENTATIONS. 3. CONTACTS ARE SIZE 23. GASKET REAR INSULATOR GROMMET NOT SUPPLIED 2. MATERIAL / FINISH: PLUG BARREL, COUPLING NUT, HOUSING, COVER - ALUMINUM ALLOY OR STAINLESS STEEL / SEE TABLE I INSULATOR - LCP / NONE. INTERFACIAL SEAL, GASKET - FLUOROSILICONE / NONE CONTACT - COPPER ALLOY / GOLD PLATE PER ASTM B 488, TYPE II, CODE C, CLASS 1.25 (.00005 MIN THK), OVER A SUITABLE UNDERPLATE CONTACT RETENTION CLIP - BERYLLIUM COPPER ALLOY / NONE HARDWARE - STAINLESS STEEL / PASSIVATE OR BLACK OXIDE RETAINING WIRE - TORLON / NONE DETENT SPRING, RIVET - STAINLESS STEEL / PASSIVATE EMI GROUND SPRING - BERYLLIUM COPPER / ELECTROLESS NICKEL 1. ASSEMBLY TO BE IDENTIFIED WITH GLENAIR'S NAME, PART NUMBER, AND DATE CODE, SPACE PERMITTING. NOTES: CONTACT GLENAIR FOR ADDITIONAL FINISHES Z1 ZNU NF CLASS M MT ± 1/16 ± 2° .XXX .XX ± .015 ± .03 B/F 11C8797 P/C 80 DO NOT SCALE THIS DRAWING ANGLES DECIMALS FRACTIONS D MAX ASSEMBLED REV A B 07/19/12 07/19/12 07/19/12 07/18/12 07/18/12 APPROVED RELEASE DATE ORIGINAL RELEASE DATE APPROVED EAG GSB EAG 1 MASTER KEY SCALE N.A. WEIGHT N.A. SHEET 1 OF 805-061 CODE IDENT. NO. SIZE DRAWING NO. 06324 A PLUG CONNECTOR, SERIES 805 STYLE RATCHETING COBRA 1211 AIR WAY - GLENDALE - CALIFORNIA 91201 B 2 REV. F 7 APPROVED EAG EAG FACE VIEW OF PLUG AS VIEWED FROM ENGAGING END (10-13PA1 SHOWN) J ENTRY SIZE DATE 07/19/12 02/12/13 805-061 GLENAIR, INC. TITLE øA B THREAD REVISION HISTORY DESCRIPTION PRODUCTION RELEASE REVISED PER DCN #45302 UNLESS OTHERWISE SPECIFIED DRAWN CHECK DIMENSIONS ARE IN INCHES ENGR TOLERANCES E MAX ASSEMBLED THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC. S:\part\s8\80\805-0611OF2.prt 1 of 1 (POSITION A SHOWN) KEY POSITION 805-061 -16 ZNU 9-10 P A 1 05 = = = = PIN, SOLDER SOCKET, SOLDER PIN, CRIMP SOCKET, CRIMP CABLE ENTRY SIZE (SEE TABLE VI) 1 THROUGH 8 (SEE TABLE IV) CABLE EXIT DIRECTION A THROUGH F (SEE TABLE III) KEY POSITION A B P S CONTACT STYLE (SEE TABLE V) SHELL SIZE - CONTACT ARRANGEMENT CLASS (SEE TABLE I) -16 = PLUG CONNECTOR WITH RATCHETING ANTI-DECOUPLING MECHANISM SHELL STYLE CONNECTOR SERIES EXAMPLE: ± 1/16 ± 2° .XXX .XX ± .015 ± .03 B/F 11C8797 P/C 80 DO NOT SCALE THIS DRAWING ANGLES DECIMALS FRACTIONS G MAX MASTER KEY (DIRECTION 2 SHOWN) SCALE N.A. WEIGHT N.A. SHEET 2 OF 805-061 CODE IDENT. NO. SIZE DRAWING NO. 06324 A PLUG CONNECTOR, SERIES 805 STYLE RATCHETING COBRA 1211 AIR WAY - GLENDALE - CALIFORNIA 91201 GLENAIR, INC. TITLE C° TABLE VI-CABLE ENTRY CODE ENTRY SIZE 02 .125 03 .188 .250 04 05 .313 06 .375 07 .438 08 .500 09 .563 10 .625 11 .688 12 .750 13 .813 .875 14 15 .938 16 1.000 17 1.063 805-061 B 2 REV. CABLE EXIT DIRECTION JAM NUT RECEPTACLE MATING SPACE REQUIREMENT 07/19/12 07/19/12 07/19/12 07/18/12 07/18/12 APPROVED APPROVED EAG GSB EAG RELEASE DATE ORIGINAL RELEASE DATE UNLESS OTHERWISE SPECIFIED DRAWN CHECK DIMENSIONS ARE IN INCHES ENGR TOLERANCES SQUARE FLANGE RECEPTACLE MATING SPACE REQUIREMENT .060 [1.52] TABLE V - AVAILABLE ARRANGEMENTS SHELL SIZE CONTACT ARRANGEMENT* 8-4, 8-6, 8-7 8 9 9-10 10 10-13 11 11-19 12 12-26 13 13-31 15 15-37 18 18-55 19 19-85 21 21-100 23 23-130 *: # FOLLOWING DASH = # OF CONTACTS H MAX J MAX ENTRY .560 [14.22] 04 .650 [16.51] 05 .710 [18.03] 06 .770 [19.56] 07 .835 [21.21] 08 T.B.D. 09 10 .950 [24.13] T.B.D. 12 1.180 [29.97] 13 T.B.D. 15 T.B.D. 17 REVISION HISTORY SEE SHEET 1 OF 2 TABLE IV-EXIT DIRECTION DIRECTION C° 1 0° 2 45° 3 90° 4 135° 5 180° 225° 6 7 270° 8 315° H 1.62 [41.1] 1.63 [41.4] 1.65 [41.9] 1.68 [42.7] 1.71 [43.4] T.B.D. 1.77 [45.0] T.B.D. 1.92 [48.8] T.B.D. T.B.D. REAR-MOUNTED SQUARE FLANGE RECEPTACLE G 1.76 [44.7] 1.77 [45.0] 1.79 [45.5] 1.82 [46.2] 1.85 [47.0] T.B.D. 1.91 [48.5] T.B.D. 2.06 [52.3] T.B.D. T.B.D. SHOWN INSTALLED TABLE II - DIMENSIONAL DATA F D E 1.02 [25.9] .34 [8.6] 1.24 [31.5] 1.03 [26.2] .39 [9.9] 1.28 [32.5] 1.05 [26.7] .42 [10.7] 1.31 [33.3] 1.08 [27.4] .45 [11.4] 1.34 [34.0] 1.11 [28.2] .48 [12.2] 1.37 [34.8] T.B.D. T.B.D. T.B.D. 1.17 [29.7] .52 [13.2] 1.48 [37.6] T.B.D. T.B.D. T.B.D. 1.32 [33.5] .63 [16.0] 1.78 [45.2] T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. TABLE III - KEY POSITION POSITION A° B° A (NORMAL) 150° 210° B 75° 210° C 95° 230° D 275° 140° E 75° 275° F 95° 210° B THREAD .5000-.1P-.3L-TS-2B .5625-.1P-.3L-TS-2B .6250-.1P-.3L-TS-2B .6875-.1P-.3L-TS-2B .7500-.1P-.3L-TS-2B .8125-.1P-.3L-TS-2B .9375-.1P-.3L-TS-2B 1.1250-.1P-.3L-TS-2B 1.1875-.1P-.3L-TS-2B 1.3125-.1P-.3L-TS-2B 1.4375-.1P-.3L-TS-2B MASTER KEY øA .65 [15.7] .79 [20.1] .83 [21.1] .92 [23.4] .98 [24.9] 1.05 [26.7] 1.10 [27.9] 1.29 [32.8] 1.31 [33.3] 1.45 [36.8] 1.56 [39.6] PART NUMBER DEVELOPMENT B° A° SHELL SIZE 8 9 10 11 12 13 15 18 19 21 23 THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC. S:\part\s8\80\805-0612OF2.prt 1 of 1
Similar documents
Amphenol
To avoid cross-plugging problems in applications requiring the use of more than one connector of the same size and arrangement, alternate rotations are available as indicated in the chart below. As...
More informationSolderless Terminals, Terminal Blocks and Connectors
Braid: Woven bare metallic or tinned copper wire used as shielding for wires and cables and as ground wire for batteries or heavy industrial equipment. Also a woven fibrous protective outer coverin...
More informationAMPSEAL 16 Connector System
silicone seals allow the connectors to withstand extreme temperatures and moisture.
More information