Accessories - Oertli OS4
Transcription
Accessories - Oertli OS4
Accessories Content 1.Phaco a.Hexadisq® phaco handpiece, reusable b. easyPhaco® tips, single use c. easyPhaco® tips, reusable d. Various phaco accessories, single or reusable Page 4 5 6 7 8 2. Irrigation / Aspiration a. I/A handpiece coaxial, reusable b. I/A Quick tip System coaxial, reusable c. I/A handpiece bimanual, single use d. I/A handpiece bimanual, reusable 10 11 12 13 13 3. HF Function / Diathermy a. Diathermy handpiece, reusable b.HFDS® glaucoma tip, reusable c. Diathermy tip, reusable d. Endo diathermy tips, reusable e. Diathermy forceps, reusable f. Capsulotomy tip, reusable 14 15 15 15 15 17 17 4.Vitrectomy a. PMS pars plana micro incision system, single use b. Infusion terminal, single use c. Continuous Flow-Cutter, single use d. Classic pneumatic vitrectomy cutter, single use e. Light instruments, single use f. DEX™ forceps, single use g. Various vitrectomy accessories, single use or reusable 18 19 20 23 23 25 27 28 5.Laser a. Laser probes, single use b. Laser accessories, reusable 30 31 32 6. Device Accessories 33 7. Surgery Packs a. TwinVac cassette, single use b. Example phaco pack, single use c. Example vitrectomy pack, single use 34 34 34 34 Phaco easyPhaco® technology Thanks to Oertli’s clever needle design, its sophisticated fluidics concept and world class pump systems, easyPhaco® technology offers visible and tangible benefits: • Unprecedented chamber stability, perfect emulsification and extremely effective aspiration of fragments • Gentle and effective aspiration resulting in excellent followability and holdability of fragments • Concentrated axial ultrasound and highest possible power generation for perfect emulsification • Elimination of vacuum fluctuations thanks to a capillary aspiration path Oertli easyPhaco® technology is available in three different tip sizes. All incisions are covered irrespectively of whether you work with sub 2 mm coaxial micro phaco or with standard incision sizes up to 3.2 mm. Recommended setting for easyPhaco® Minimum Venturi pump easyTip® CO-MICS for incisions of 1.6 - 1.8 mm easyTip® 2.2 mm for incisions of 2.2 - 2.4 mm easyTip® 2.8 mm for incisions of 2.8 - 3.2 mm Phaco 1 (Grooving) Phaco 2 Phaco 1 (Grooving) Phaco 2 Phaco 1 (Grooving) Phaco 2 Vacuum (mmHg) 80 250 80 400 80 400 Peristaltic pump/SPEEP® mode Vacuumeffect (%) 60 60 60 60 60 60 Flow (ml/min) 18 20 18 40 18 40 Vakuum (mmHg) 50 250 50 400 50 400 Maximum Venturi pump easyTip® CO-MICS for incisions of 1.6 - 1.8 mm easyTip® 2.2 mm for incisions of 2.2 - 2.4 mm easyTip® 2.8 mm for incisions of 2.8 - 3.2 mm Phaco 1 (Grooving) Phaco 2 Phaco 1 (Grooving) Phaco 2 Phaco 1 (Grooving) Phaco 2 Vacuum (mmHg) 100 350 100 500 100 500 Peristaltic pump/SPEEP® mode Vacuumeffect (%) 80 100 80 100 80 100 • Recommended height of bottle: 100 cm above patient’s eye. • Recommended additional settings: Pulse mode, 40 Hz, 60 % cooling for phaco 2. easyPhaco® is a development by Oertli® R&D in scientific collaboration with Prof. Rupert Menapace, Vienna. Flow (ml/min) 18 28 18 50 18 50 Vacuum (mmHg) 50 350 50 500 50 500 5 a. Hexadisq® phaco handpiece, reusable Having an outside diameter of 13 mm, an internal in fusion tube, being extremely light weight (47 grams) and completely made of titanium, the Hexadisq® phaco handpiece has set the standards since 2002. The handpiece, which is equipped with 6 piezo crystals, is ideally suited for easyPhaco® technology and MICS. VG800011 U/S phaco handpiece with cable 3 m VV803200 Protection cap for phaco handpiece, titan Phaco Phaco b. easyPhaco® tips, single use Sterile/single use, box of 10 including sleeve, test chamber, phaco key and emergency key VV806833A Titanium easyTip® CO-MICS, 30° for incisions of 1.6 - 1.8 mm VV806833 Titanium easyTip® CO-MICS, 53° for incisions of 1.6 - 1.8 mm VV806835B Titanium easyTip® 2.2 mm, 15° for incisions of 2.2 - 2.4 mm VV806835A Titanium easyTip® 2.2 mm, 30° for incisions of 2.2 - 2.4 mm VV806835 Titanium easyTip® 2.2 mm, 40° for incisions of 2.2 - 2.4 mm VV806840 Titanium easyTip® 2.8 mm, 30° for incisions of 2.8 - 3.2 mm 7 c. easyPhaco® tips, reusable VV800831 Titanium easyTip® CO-MICS, 30° for incisions of 1.6 - 1.8 mm VV800833 Titanium easyTip® CO-MICS, 53° for incisions of 1.6 mm - 1.8 mm VV603231 Irrigation sleeve for easyTip® CO-MICS, Silicone, grey VV800735B Titanium easyTip® 2.2 mm, 15° for incisions of 2.2 - 2.4 mm VV800735A Titanium easyTip® 2.2 mm, 30° for incisions of 2.2 - 2.4 mm VV800735 Titanium easyTip® 2.2 mm, 40° for incisions of 2.2 - 2.4 mm VV603220 Irrigation sleeve for easyTip® 2.2 mm, Silicone, transparent VV800740 Titanium easyTip® 2.8 mm, 30° for incisions of 2.8 - 3.2 mm VV603209 Irrigation sleeve for easyTip® 2.8 mm, Silicone, blue Phaco Phaco d. Various phaco accessories, single or reusable VE800100 Key for Phaco Tips with titanium insert VV803100 Test chamber for phaco, silicone VV632006 Active infusion set Sterile/single use, box of 6 9 Phaco Irrigation / Aspiration Quick Tips with Safety Design 1 Extended leg length for better sub-incisional accessibility 2 Downsizing of aspiration opening for better occludability, safety during aspiration and a stable anterior chamber 3 Repositioning of the aspiration opening that prevents from unintentional grasping of the capsular bag Features and benefits The Quick Tips with Safety Design, especially in combination with the SPEEP® Mode, provide the highest standard of safety, control and efficiency in the procedure of I/A. In detail, we provide the following benefits: • Completely stable anterior chamber • Improved sub-incisional accessibility • Better occludability • High standard of safety during capsule cleaning process Additionally, the tips are equipped with the sophisticated Quick Tip snap-on lock closing that enables a fast change of the tip in the sterile field. The I/A Quick Tips with Safety Design are intended for application with sleeve. 11 a.I/A Handpiece coaxial, reusable VE655000 I/A Handpiece Quick Tip, titanium VE603010 Irrigations handpiece «Titano» with Luer connection VE655020 Luer adaptor Quick Tip female Irrigation / Aspiration Irrigation / Aspiration b.I/A Quick Tip system coaxial, reusable VE655527 Quick tip for I/A with sleeve, 45°, aspiration opening 0.25 mm, leg length 1.2 mm, for incisions from 1.6 - 1.8 mm, SAFETY DESIGN VE655525 Quick tip for I/A with sleeve, 45°, aspiration opening 0.25 mm, leg length 1.5 mm, for incisions from 2.2 - 3.2 mm, SAFETY DESIGN VE655526 Quick tip for I/A with sleeve, 45°, aspiration opening 0.25 mm, leg length 2.1 mm, for incisions from 2.2 -‐3.2 mm, SAFETY DESIGN VE655535 Quick tip for I/A with sleeve, 45°, aspiration opening 0.35 mm, leg length 1.5 mm, for incisions from 2.2 -‐3.2 mm VE655035 Quick tip for I/A with sleeve, straight, aspiration opening 0.35 mm, for incisions from 2.2 - 3.2 mm VV603231 Irrigation sleeve for easyTip® CO-MICS, silicone, grey (for VE655527) VV603220 Irrigation sleeve for easyTip® 2.2 mm, silicone, transparent (for VE655035, VE655525, VE655526, VE655535) VV603209 Irrigation sleeve silicone for easyTip® 2.8 mm, silicone, blue (for VE655035, VE655525, VE655526, VE655535) VE655235 Quick tip for I/A, sleeveless, 45°, aspiration opening 0.35 mm, leg length 1.5 mm, for incisions from 2.8 - 3.2 mm, diameter 1.80 mm 13 c. I/A handpiece bimanual, single use Sterile/single use, box of 10 VV650010 I/A bimanual instruments set d. I/A handpiece bimanual, reusable VE654100 I/A bimanual instrument kit, (1 irrigation and 1 aspiration instrument) VE654101 I/A bimanual instrument kit, roughened tips VE654103 I/A bimanual instrument kit 23G Irrigation / Aspiration HF Function / Diathermy HFDS® ab interno MIGS technology High Frequency Deep Sclerotomy (HFDS) glaucoma surgery is a new ab interno procedure to lower the intraocular pressure in open-angle glaucoma. Using high frequency energy, six small pockets are formed in the iridocorneal angle, which significantly reduce the outflow resistance for aqueous humour. Area of application Features and benefits • Ideal for combinations with cataract surgeries • Very short intervention times • No bleb formation • No corneal scars • No fibroblast movement to the sclera • Procedure can be repeated Positioning of abee® tip Literature Pallas G, Pajic B. 1999: Die Sklerathalamektomie (STE): Stabile post operative Augendruckregulierung beim Offenwinkel- und Kapsel häutchenglaukom. Klein Monatsbl Augenheilk 2000; 216:256-260 Forming of sclerotomy bags Pajic B. Pallas G, Gerding H, Böhnke M.: A novel technique of ab interno glaucoma surgery: follow-up results after 24 months. Graefes Arch Clin Exp Opthalmol 2005 Jul; 19:1-6 50 45 Pajic B.: High-Frequency Deep Sclerotomy, Cataract & Refractive Surgery Today, October 2011 40 mmHg 35 30 25 20 15 10 5 1 2 3 4 7 1 3 6 9 1215182124273033363942454851545760636816972 Pre-op | Days 0 | Months Excellent long-term results (72 months) after conducted HFDS® procedure. 15 a. Diathermy handpiece, reusable VE201710 Handpiece long, plug-on, diathermy, cable 3 m, floating connector (black) VE201712 Handpiece short, plug-on, diathermy, capsulotomy, cable 3 m, floating connector b. HFDS® glaucoma tip, reusable VE201751 abee® glaucoma tip, ab interno, High Frequency Deep Sclerotomy c. Diathermy tips, reusable VE201722 Diathermy plug-on tip «Eraser», 1.1 mm, 25 mm, 50° bevel d. Endo diathermy tips, reusable VE201723 Endo diathermy plug-on tip, 20G, 28 mm, 54° pointed VE201733 Endo diathermy plug-on tip, 23G, 28 mm, 54° pointed VE201732 Endo diathermy plug-on tip, 25G, 28 mm, 54° pointed VE201724 Endo diathermy plug-on tip, 20G, 28 mm, 54° pointed, tapered 0.45 mm HF Function / Diathermy 17 e.Diathermy forceps, reusable VE203902 Bipolar forceps plug-on curved f. Capsulotomy tip, reusable VE201726 Capsulotomy plug-on tip standard VE201730 Capsulotomy plug-on tip long, 0.5 mm capsular Fimosis HF Function / Diathermy Vitrectomy Caliburn™ trocar cannula system «The lancet-pointed needle from Oertli had remarkable low piercing and cutting forces.» Independent study* Features and benefits • Superb post-operative wound tightness • New surface finish for even smoother incisions • Less resistance on trocar edge-entry • Patented snap-on lock infusion line for more flexibility • Incision template for exact trocar placement Application • Patented integrated, double-slotted sealing membrane • Easy finding and entry with instruments • Reliably constant IOP during surgery • Reliable retention of the trocar • Color coded for each gauge size (23G, 25G) 1. Pull the conjunctiva slightly sideways over the sclera with the Oertli® incision template. 2. Insert the trocar in the sclera through the incision opening by holding cannula blade at an angle of maximum 30°. 3. After inserting the blade, lift the blade vertically and gently penetrate the sclera with the instrument. 4. Insert the trocar completely until its head touches the sclera. The shaft is now fully inserted. 5. Connect the infusion line with the patent-registered snap mechanism to the trocar. Insert the remaining trocars in the sclera using the above mentioned procedure (steps 1 to 4). *Source: Geometry, penetration force, and cutting profile of different 23-gauge trocars systems for pars plana vitrectomy, C.H. Meyer MD, H. Kaymak MD, published in the November 2014 issue of the Retina Journal (Volume: 34:2290–2299, 2014). 19 a. PMS Pars Plana micro incision system, single use Sterile/single use, box of 10 23G VV123311 Caliburn PMS system, one step, self sealing 25G VV125311 Caliburn PMS system, one step, self sealing Vitrectomy Vitrectomy Sterile/single use, box of 10 23G VV123211 Infusion line 6 mm for PMS, self sealing 23G VV123212 23G infusion trocar with infusion line and mandrel for PMS system VV125110 PMS incision template b. Infusion terminal, single use Sterile/single use, box of 10 20G VV690220 Infusion terminal 4 mm, BSS 20G VV690221 Infusion terminal 4 mm, silicone 6000CS 20G VV690230 Infusion terminal 6 mm, BSS 20G VV690231 Infusion terminal 6 mm, silicone 6000CS 20G VV690320 Infusion terminal «No Stitch» 4.5 mm 20G VV690330 Infusion terminal «No Stitch» 6 mm 21 Vitrectomy Vitrectomy Continuous Flow-Cutter – a new level of vitrectomy cutter «This cutter is very efficient and effective. I have got an outstanding control for peripheral vitreous removal» Early user, Italy Features and benefits • 100% continuous flow for tear-free high speed cutting • Perfect portioning of vitreous body removal • Highest efficiency and safety in core vitrectomy • Excellent precision for all maneuvers • Ability to peel and manipulate membranes • Continuous holding force • Absolute minimal distance of cutter port from the distal end • Pneumatic push-pull cutter (no spring) • Double cut-rate Vitreous body removal – Continuous Flow-Cutter: Continuous flow without any notice able fluctuations. With each cycle, vitreous body is removed twice – Standard Cutter: Flow is interrupted with each cycle. With each cycle, vitreous body is removed once 23 c. Continuous Flow-Cutter, single use Sterile/single use, box of 10 20G VV104110 Continuous Flow-Cutter, Twinac® 23G VV106110 Continuous Flow-Cutter, Twinac® 25G VV105110 Continuous Flow-Cutter, Twinac® d. Classic pneumatic vitrectomy cutter, single use Sterile/single use, box of 10 20G VV104010 SPS Twinac® Vitrectomy Cutter 23G VV106010 SPS Twinac® Vitrectomy Cutter 25G VV105010 SPS Twinac® Vitrectomy Cutter Vitrectomy Vitrectomy Endo illuminator panorama – wide panorama illumination Features and benefits • Wide panoramic tip for optimal illumination • Shielded design to avoid glare during the procedure •Oertli® micro-connector • Color coded by gauge size 25 e. Light instruments, single use Sterile/single use, box of 10 20G VV300101 Endo illuminator 90°, micro connector 23G VV300103 Endo illuminator 90°, micro connector 25G VV300105 Endo illuminator 90°, micro connector 20G VV300191 Endo illuminator Panorama, shielded, micro connector 23G VV300194 Endo illuminator Panorama, shielded, micro connector 25G VV300195 Endo illuminator Panorama, shielded, micro connector Vitrectomy Vitrectomy DEX™ disposable forceps «The best ILM forceps, I have ever used» Early user, Germany Features and benefits • Perfect ergonomics achieved by 360° actuation • Short efficient stroke for direct closing of the instrument • Precise grasping due to the carefully manufactured tips • Excellent holding force stemming from a superior tip design • No shredding of the peeled membrane due to tips without sharp edges 27 f. DEX™ forceps, single use Sterile/single use, box of 10 23G DVF4019-23 DEX Maculorhexis forceps 25G DVF4019-25 DEX Maculorhexis forceps 23G DVF4022-23 DEX End Grasping forceps 25G DVF4022-25 DEX End Grasping forceps 23G DVF4005-23 DEX Nanotapered Awh forceps 25G DVF4005-25 DEX Nanotapered Awh forceps Vitrectomy Vitrectomy g. Various vitrectomy accessories, single use or reusable VV690101 Sterile/single use, box of 10 Air delivery line with filter and air/BSS connector VV690310 Sterile/single use, box of 10 Silicone application set 20 cc, visco system VV800051 Titanium tip, Phaco, for Pars Plana phacoemulsification, 20G 29 Vitrectomy Laser Laser probes – precisely controlled laser application «Excellent how I can control the bending of the probe with my fingertips. I was able to create spots in different rows simply be squeezing the laser probe.» Early user, Switzerland Features and benefits • 0 to 90° bending angle of the tip – outstanding reach to the peripheral retina • Ergonomic handle with 360° actuation • Control of the bending at the surgeon’s fingertips – allowing to position different rows of laser with gentle surgeon control • Naturally straight – therefore safe to remove without having to retract the curved fiber 31 a. Laser probes, single use Sterile/single use, box of 10 20G VK400101 Laser probe, straight 23G VK400103 Laser probe, straight 25G VK400105 Laser probe, straight 20G VK400111 Laser probe, curved 23G VK400113 Laser probe, flexible curved 23G 25G VK400115 Laser probe, flexible curved 23G 23G VK400123 Laser probe, steerable 25G VK400125 Laser probe, steerable Laser Laser b. Laser accessories, reusable F18.P1E01.1001MED Filter impact OD6+, blocked wavelength 532 nm 340833 User Protection Filter Zeiss / HS Moeller Microscope 340846 User Protection Filter Leica Microscope 340990 User Protection Filter Topcon Microscope 33 Device Accessories VE860010 Programmable wireless pedal, dual linear VE860030 Cover VE860001 Instrument tray Device Accessories OP Packs a.Cassette TwinVac Sterile/single use, box of 10 VV660010 I/A cassette TwinVac including giving set and display cover bag b.Example phaco pack Sterile/single use, box of 10 VV660011D Phaco pack OS4, cassette, easyTip® 2.2 mm, 40°, sleeve, test chamber, phaco key, emergeny key, giving set, display cover bag c. Example vitrectomy pack Sterile/single use, box of 6 VV660113BP Vitrectomy pack OS4, 23G, cassette, Caliburn cannula system autoseal One Step, SPS, panorama light shielded, air with connector Air/BSS, giving set, display cover bag Further phaco and vitrectomy packs are available on request. 35 Reprocessing and sterilization Norms and quality control All disposable products labelled with this symbol are delivered in a sterile state and are intended for single use. They must not be reused. Oertli® attaches utmost importance to quality and continuous improvement of its products and quality management systems. All products listed in this catalogue correspond to the high Swiss quality standard and bear the CE marking. Reusable products, which are not labelled with this symbol , are suited for multiple use. Reprocessing of these products must be carried out according to Oertli® instructions for use TN999042 “Instructions for Processing (Cleaning, Disinfection and Sterilization) of Instruments”. The procedures described in TN999042 have been validated according to ISO 17665-1. Oertli® uses the following standard dimensions (outer dia meter) 20G 0.89 mm 23G 0.64 mm 25G 0.51 mm Packaging recommended for sterilization: Possible packaging that can be used for reprocessing the various reusable products are described in Oertli® instructions for use TN999042. Disclaimer All details in this catalogue were correct at the time of publication. There may be changes without notice as a result of enhancements to the design or safety of products. The details specified in the relevant quotation or delivery documentation shall apply. Oertli Instrumente AG CH-9442 Berneck Fax +41 (0)71 747 42 90 Switzerland Phone +41 (0)71 747 42 00 www.oertli-instruments.com info@oertli-instruments.com Ecknauer+Schoch ASW. BD1040.E 2015.11 www.oertli-os4.com
Similar documents
- Oertli Instrumente AG
The I/A Quick Tips with Safety Design are intended for application with sleeve.
More informationPDF Oertli Instrumente TITANO
are Class 11a products that may only be used in combination with Oertli® control equipment. They conform to one or more of the following standards: ISO 11135-1, ISO 17665-1, EN556-1, IEC 60601-1, I...
More information