dw-4000 - horizontal installation
Transcription
dw-4000 - horizontal installation
DW-4000 - HORIZONTAL INSTALLATION AR-PJ-01-DW4H AR-PJ-02-DW4H AR-PJ-03-DW4H AR-PJ-04-DW4H AR-PJ-05-DW4H AR-PJ-06-DW4H AR-PJ-07-DW4H AR-PJ-08-DW4H AR-PJ-09-DW4H AR-PJ-10-DW4H AR-PJ-11-DW4H AR-PJ-12-DW4H AR-PJ-13-DW4H AR-PJ-14-DW4H AR-PJ-15-DW4H AR-BS-01-DW4H AR-BS-02-DW4H AR-BS-03-DW4H AR-BS-04-DW4H AR-OC-01-DW4H AR-OC-02-DW4H AR-OC-03-DW4H AR-OC-04-DW4H AR-IC-01-DW4H AR-IC-02-DW4H AR-IC-03-DW4H 2" HORIZONTAL PANEL JOINT 2" PANEL VERTICAL REVEAL 212" HORIZONTAL PANEL JOINT 212" PANEL VERTICAL REVEAL 3" HORIZONTAL PANEL JOINT 3" PANEL VERTICAL REVEAL 4" HORIZONTAL PANEL JOINT 4" PANEL VERTICAL REVEAL CUSTOM REVEAL DW-4000S PANEL PROFILE DW-4000H TO DW-4000V TRANSITION VERTICAL REVEAL W/ EXTRUSION PANELS OVER STRUCTURAL STEEL PANELS OVER METAL STUDS PANELS OVER CONCRETE BASE DETAIL - FLUSH BASE DETAIL - OVERHANG BASE DETAIL AT VERTICAL JOINT (FLUSH) BASE DETAIL AT VERTICAL JNT. (OVERHANG) TRANSVERSE BENT CORNER OUTSIDE CORNER WITH EXTRUSION OUTSIDE CORNER WITH FLAT TRIM INSIDE CORNER WITH EXTRUSION INSIDE CORNER WITH TRIMLESS ENDS INSIDE CORNER WITH FLUSH TRIM INDEX SHEET 1 DW-4000 - HORIZONTAL INSTALLATION AR-FO-04-DW4H AR-FO-05-DW4H AR-FO-06-DW4H AR-FO-07-DW4H AR-FO-08-DW4H AR-FO-09-DW4H AR-FO-10-DW4H AR-FO-11-DW4H AR-SF-01-DW4H AR-SF-02-DW4H AR-SF-03-DW4H AR-PR-01-DW4H AR-PR-02-DW4H AR-PR-03-DW4H AR-TL-01-DW4H AR-TL-02-DW4H AR-TL-03-DW4H AR-TL-03B-DW4H AR-TL-04-DW4H AR-TL-04B-DW4H AR-TL-05-DW4H AR-TL-06-DW4H AR-TL-07-DW4H AR-TL-08-DW4H AR-TL-09-DW4H AR-TL-10-DW4H AR-TL-11-DW4H AR-TL-12-DW4H F.O. TWO PIECE HEAD F.O. HEAD WITH DRIP EDGE F.O. TWO PIECE JAMB F.O. ONE PIECE JAMB F.O. ONE PIECE SILL F.O. HEADER WITH EXTRUSION F.O. JAMB WITH EXTRUSION F.O. SILL WITH EXTRUSION WALL TO SOFFIT LONGITUDINAL BENT SOFFIT WALL TO FIELD CUT SOFFIT INTEGRATED PARAPET COPING PARAPET W/ FLUSH TRIM PARAPET W/ FLUSH EXTRUSION WALL PENETRATION WALL PENETRATION SECTION 2" EXTRUSIONS 212" EXTRUSIONS 3" EXTRUSIONS 4" EXTRUSIONS EXTRUSION LAP STRIPS TRIM END LAP TRIM LAP WITH HEM MENDING PLATE "SHINGLE" LAP TRIM END LAP WITH LAP STRIP TRIM AT FRAMED OPENINGS EXTRUSION AT FRAMED OPENING ACCESSORIES INDEX SHEET 2 DW-4000 - HORIZONTAL INSTALLATION DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED ON TYPICAL DESIGN PRACTICES FOR MOST U.S. CLIMACTIC ZONES. (THE PRIMARY VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER). CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS EXTRUSION SHAPES / ENGAGEMENT MAY VARY FROM THOSE SHOWN. PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION PURPOSES ONLY. ARCHITECTURAL DISCLAIMER 24", 30" OR 36" MODULE STANDARD INTERLOCK JOINT FINNED GASKET FACE OF PANEL FACE SHEET WEDGE GASKET REVEAL S.S. BI-METAL TEK 3 SCREW 2" S.S. FASTENING CLIP WITH PVC FOAM TAPE STRIP SEAL 1 DIRECTION OF INSTALLATION DW-4000 - HORIZONTAL INSTALLATION VERTICAL SUPPORTS BY OTHERS 2" FASTENING CLIP CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS 2" HORIZONTAL PANEL JOINT DW-4000 - HORIZONTAL INSTALLATION 6" RECOMMENDED BEARING FRAMING BY OTHERS CONTINUOUS MENDING PLATE 2" CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW 1 2" VERTICAL JOINT GASKET PANEL LENGTH MEASURED FROM HERE 2" PANEL VERTICAL REVEAL PANEL LENGTH MEASURED FROM HERE 24", 30" OR 36" MODULE FACE OF PANEL STANDARD INTERLOCK JOINT FINNED GASKET FACE SHEET WEDGE GASKET REVEAL S.S. BI-METAL TEK 3 SCREW 2" S.S. FASTENING CLIP WITH PVC FOAM TAPE STRIP SEAL 1 DIRECTION OF INSTALLATION DW-4000 - HORIZONTAL INSTALLATION VERTICAL SUPPORTS BY OTHERS 212" FASTENING CLIP CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS 212" HORIZONTAL PANEL JOINT DW-4000 - HORIZONTAL INSTALLATION 6" RECOMMENDED BEARING FILL VOID WITH COMPRESSIBLE FOAM CLOSURE FRAMING BY OTHERS CONTINUOUS MENDING PLATE 212" CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW 1 2" VERTICAL JOINT GASKET PANEL LENGTH MEASURED FROM HERE 212" PANEL VERTICAL REVEAL PANEL LENGTH MEASURED FROM HERE DW-4000 - HORIZONTAL INSTALLATION 24", 30" OR 36" MODULE FACE OF PANEL STANDARD INTERLOCK JOINT FINNED GASKET REVEAL S.S. BI-METAL TEK 3 SCREW S.S. FASTENING CLIP WITH PVC FOAM TAPE STRIP SEAL 1 2" DIRECTION OF INSTALLATION FACE SHEET WEDGE GASKET VERTICAL SUPPORTS BY OTHERS 3" FASTENING CLIP CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS 3" HORIZONTAL PANEL JOINT DW-4000 - HORIZONTAL INSTALLATION 6" RECOMMENDED BEARING FILL VOID WITH COMPRESSIBLE FOAM CLOSURE FRAMING BY OTHERS CONTINUOUS MENDING PLATE 3" CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW 1 2" VERTICAL JOINT GASKET PANEL LENGHT MEASURED FROM HERE 3" PANEL VERTICAL REVEAL PANEL LENGTH MEASURED FROM HERE DW-4000 - HORIZONTAL INSTALLATION 24", 30" OR 36" MODULE FACE OF PANEL STANDARD INTERLOCK JOINT FINNED GASKET REVEAL S.S. BI-METAL TEK 3 SCREW S.S. FASTENING CLIP WITH PVC FOAM TAPE STRIP SEAL 1 2" DIRECTION OF INSTALLATION FACE SHEET WEDGE GASKET VERTICAL SUPPORTS BY OTHERS 4" FASTENING CLIP CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS 4" HORIZONTAL PANEL JOINT DW-4000 - HORIZONTAL INSTALLATION 6" RECOMMENDED BEARING FILL VOID WITH COMPRESSIBLE FOAM CLOSURE FRAMING BY OTHERS CONTINUOUS MENDING PLATE 4" CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 1 2" FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW VERTICAL JOINT GASKET PANEL LENGHT MEASURED FROM HERE 4" PANEL VERTICAL REVEAL PANEL LENGTH MEASURED FROM HERE PANEL MODULE DW-4000 - HORIZONTAL INSTALLATION FACE OF PANEL 6" MAX. 11 " 16 S.S. BI-METAL TEK 3 SCREW S.S. FATENING CLIP WITH PVC FOAM TAPE STRIP SEAL REVEAL MODIFICATION BUILT INTO LOWER PANEL VERTICAL SUPPORT BY OTHERS FASTENING CLIP NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED AT TERMINATIONS CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS CUSTOM REVEAL DW-4000S - HORIZONTAL INSTALLATION STANDARD INTERLOCK JOINT FINNED GASKET REVEAL FACE SHEET WEDGE GASKET 114" STRIATION PITCH 24", 30", OR 36" MODULE STANDARD FACE OF PANEL STRIATED FACE SHEET STRIATION DEPTH .035 INCH 2", 2.5", 3", OR 4" DW-4000S PANEL PROFILE DW-4000 - HORIZONTAL INSTALLATION 6" RECOMMENDED BEARING FRAMING BY OTHERS CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT MODIFIED EDGE ON VERTICAL PANEL 2 - PC FASTENING CLIP WITH 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER 2" OR 3" 1 DESIGNWALL 4000H PANEL DESIGNWALL 4000V PANEL VERTICAL JOINT GASKET 1 HORIZONTAL PANEL LENGTH MEASURED HERE DW-4000H TO DW-4000V TRANSITION 2" VERTICAL PANEL LENGTH MEASURED HERE DW-4000 - HORIZONTAL INSTALLATION 6" RECOMMENDED BEARING FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW 16 GAUGE MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 2" OR 3" FRAMING BY OTHERS BLACK EPDM GASKET 7 8" 3 4" 7 8" 212" PLUG ENDS OF HORIZ. JOINTS WITH SILICONE SEALANT* PVC FOAM GASKET ALUMINUM TOP HAT JOINT EXTRUSION ALUMINUM JOINT EXTRUSION ALTERNATIVES ALUMINUM FLUSH INSERT ALUMINUM RECESSED INSERT *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED AT TERMINATIONS VERTICAL REVEAL W/ EXTRUSION DW-4000 - HORIZONTAL INSTALLATION ALWAYS ATTACH HORIZONTAL PANELS TO VERTICALLY ORIENTED SUPPORTS VERTICAL TUBES VERTICAL TUBES HORIZONTAL PANELS PANELS OVER STRUCTURAL STEEL DW-4000 - HORIZONTAL INSTALLATION ALWAYS ATTACH HORIZONTAL PANELS TO VERTICALLY ORIENTED SUPPORTS VERTICAL STUDS HORIZONTAL PANELS PANELS OVER METAL STUDS SHEATHING OPTIONAL DW-4000 - HORIZONTAL INSTALLATION ALWAYS ATTACH HORIZONTAL PANELS TO VERTICALLY ORIENTED SUPPORTS VERTICAL SUBGIRTS HORIZONTAL PANELS PRECAST OR CMU WALL PANELS OVER CONCRETE DW-4000 - HORIZONTAL INSTALLATION 2", 2.5", 3", OR 4" CONTINUOUS BUTYL SEALANT 1 4"-14 "LOW PROFILE" FASTENERS CONCEALED BASE EXTRUSION FIELD DRILL 3 8 WEEP HOLES (NOT BY KINGSPAN) BED SEAL TO CONCRETE FABRICATED BASE TRIM BASE DETAIL - FLUSH DW-4000 - HORIZONTAL INSTALLATION 2", 2.5", 3", OR 4" CONTINUOUS BUTYL SEALANT CONCEALED BASE EXTRUSION FIELD DRILL 3 8 WEEP HOLES (NOT BY KINGSPAN) BASE DETAIL OVERHANG 1 4"-14 "LOW PROFILE" FASTENER DW-4000 - HORIZONTAL INSTALLATION 6" RE C. VERTICAL JOINT GASKET (SHOWN) OR FIELD APPLIED BACKER ROD AND SEALANT CONTINUOUS MENDING PLATE BUTYL SEALANT CONTINUOUS BEADS "SHINGLE" LAP MENDING PLATE OVER FLASHING. SEE AR-TL-08-DW4H FLASHING BEHIND AND UNDER BASE EXTRUSION BASE EXTRUSION W/ BUTYL SEALANT BELOW STOP EXTRUSION SHORT OF PANEL EDGE MARRIAGE BEAD TO JOINT SEALANT BASE DETAIL AT VERTICAL JOINT (FLUSH) SEALANT (NOT BY KINGSPAN) DW-4000 - HORIZONTAL INSTALLATION 5" RE C . VERTICAL JOINT GASKET (SHOWN) OR FIELD APPLIED BACKER ROD AND SEALANT CONTINUOUS MENDING PLATE BUTYL SEALANT CONTINUOUS BEADS FLASHING BEHIND BASE EXTRUSION W/ BUTYL SEALANT BELOW STOP EXTRUSION SHORT OF PANEL EDGE MARRIAGE BEAD TO JOINT SEALANT BASE DETAIL AT VERTICAL JOINT (OVERHANG) SEALANT (NOT BY KINGSPAN) DW-4000 - HORIZONTAL INSTALLATION 2", 2.5", 3", OR 4" FRAMING BY OTHERS CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW FACTORY TRANSVERSE BEND SHORT LEG 4'-0 MAXIMUM, TOTAL LENGTH 14'-0 MAX. TRANSVERSE BENT CORNER DW-4000 - HORIZONTAL INSTALLATION 2", 2.5", 3", OR 4" FRAMING BY OTHERS PANEL LENGTH CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 3 8" FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW 3 PANEL LENGTH 8" 1 2" VERTICAL JOINT GASKET DW-4000 - HORIZONTAL INSTALLATION FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW , 2" ,3 5" 2. ", R O 4" FIELD CUT PANELS TO SUIT PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 3" 3" 2-PC ARROWHEAD OUTSIDE CORNER EXTRUSION OPTIONAL WIPER GASKET (FIELD INSTALLED) *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED OUTSIDE CORNER WITH EXTRUSION DW-4000 - HORIZONTAL INSTALLATION FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW INSIDE CORNER TRIM ,2 2" ", ,3 " .5 O R 4" VERTICAL SUPPORT POP RIVETS PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* F.I.P. INSULATION AS REQUIRED (BY OTHERS) CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT OUTSIDE CORNER TRIM FIELD MITER PANELS *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED OUTSIDE CORNER WITH FLAT TRIM DW-4000 - HORIZONTAL INSTALLATION OPTIONAL WIPER GASKET (FIELD INSTALLED) 1 4" - 14 "LOW PROFILE" FASTENER FIELD CUT PANELS TO SUIT CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT VERTICAL SUPPORT 2-PC ARROWHEAD OUTSIDE CORNER EXTRUSION R 5 , 2" PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* 2. 3 ", ", 4" O FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED INSIDE CORNER WITH EXTRUSION DW-4000 - HORIZONTAL INSTALLATION CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FRAMING BY OTHERS CONTINUOUS MENDING PLATE PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* 1 2" FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW VERTICAL JOINT GASKET 2", 2.5", 3", OR 4" *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED INSIDE CORNER W/ TRIMLESS ENDS DW-4000 - HORIZONTAL INSTALLATION F.I.P. INSULATION AS REQUIRED (BY OTHERS) VERTICAL SUPPORT OUTSIDE CORNER TRIM 2", 2.5", 3", OR 4" FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT INSIDE CORNER TRIM POP RIVETS PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED INSIDE CORNER WITH FLUSH TRIM DW-4000 - HORIZONTAL INSTALLATION CONTINUOUS BUTYL SEALANT 1 INTERIOR CAP TRIM 4" - 14 "LOW PROFILE" THROUGH FASTENER CONTINUOUS BUTYL SEALANT POP RIVETS EXTERIOR CAP TRIM FRAMED OPENING (NOT BY KINGSPAN) FIELD DRILL 3 8 (NOT BY KINGSPAN) FIELD CUT FEMALE JOINTS WHERE REQUIRED DOOR/WINDOW FRAME (NOT BY KINGSPAN) EXPOSED SEALANT (NOT BY KINGSPAN) NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS F.O. TWO PIECE HEAD DW-4000 - HORIZONTAL INSTALLATION CONTINUOUS BUTYL SEALANT 1 4" - 14 "LOW PROFILE" THROUGH FASTENERS CONTINUOUS BUTYL SEALANT POP RIVETS EXTERIOR CAP TRIM FRAMED OPENING (NOT BY KINGSPAN) DRIP FLASHING FIELD CUT FEMALE JOINTS WHERE REQUIRED DOOR/WINDOW FRAME (NOT BY KINGSPAN) EXPOSED SEALANT (NOT BY KINGSPAN) NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS F.O. HEAD WITH DRIP EDGE DW-4000 - HORIZONTAL INSTALLATION FRAMED OPENING (NOT BY KINGSPAN) DOOR/WINDOW FRAME (NOT BY KINGSPAN) CONTINUOUS BUTYL SEALANT FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW INTERIOR CAP TRIM EXPOSED SEALANT (NOT BY KINGSPAN) POP RIVETS FIELD CUT PANELS WHERE REQUIRED CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT EXTERIOR CAP TRIM PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* POP RIVETS NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS 3) FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED F.O. TWO PIECE JAMB DW-4000 - HORIZONTAL INSTALLATION FRAMED OPENING (NOT BY KINGSPAN) 1 DOOR/WINDOW FRAME (NOT BY KINGSPAN) 4" - 14 "LOW PROFILE" FASTENERS (AS REQUIRED) CONTINUOUS BUTYL SEALANT W/ MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW CONTINUOUS BUTYL SEALANT EXPOSED SEALANT (NOT BY KINGSPAN) FIELD CUT PANELS WHERE REQUIRED POP RIVETS CAP TRIM PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS 3) FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED F.O. ONE PIECE JAMB DW-4000 - HORIZONTAL INSTALLATION CONTINUOUS BUTYL SEALANT EXPOSED SEALANT (NOT BY KINGSPAN) WINDOW FRAME (NOT BY KINGSPAN) CONTINUOUS BUTYL SEALANT FIELD CUT MALE JOINTS WHERE REQUIRED EXTERIOR CAP TRIM POP RIVETS FIELD BEND (AS REQUIRED) 1 4" - 14 "LOW PROFILE" THROUGH FASTENERS 1 4" - 14 "LOW PROFILE" FASTENERS (AS REQUIRED) FRAMED OPENING (NOT BY KINGSPAN) NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS F.O. ONE PIECE SILL DW-4000 - HORIZONTAL INSTALLATION 2", 2.5", 3", OR 4" CONTINUOUS BUTYL SEALANT 1 4" - 14 "LOW PROFILE" THROUGH FASTENERS 1 4" - 14 "LOW PROFILE" FASTENERS TWO PIECE HEAD EXTRUSION CAP CONTINUOUS BUTYL SEALANT FRAMED OPENING (NOT BY KINGSPAN) FIELD DRILL 3 8 (NOT BY KINGSPAN) FIELD CUT FEMALE JOINTS WHERE REQUIRED DOOR/WINDOW FRAME (NOT BY KINGSPAN) TWO PIECE HEAD EXTRUSION BASE EXPOSED SEALANT (NOT BY KINGSPAN) OPTIONAL WIPER GASKET (FIELD INSTALLED) NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS F.O. HEADER WITH EXTRUSION DW-4000 - HORIZONTAL INSTALLATION OPTIONAL WIPER GASKET (FIELD INSTALLED) DOOR/WINDOW FRAME (NOT BY KINGSPAN) FRAMED OPENING (NOT BY KINGSPAN) EXPOSED SEALANT (NOT BY KINGSPAN) 2", 2.5", 3", OR 4" CONTINUOUS BUTYL SEALANT W/ MARRIAGE BEAD TO HORIZONTAL PANEL JOINT TWO PIECE JAMB EXTRUSION BASE FIELD CUT PANELS WHERE REQUIRED FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW TWO PIECE JAMB EXTRUSION CAP PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS 3) FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED F.O. JAMB WITH EXTRUSION DW-4000 - HORIZONTAL INSTALLATION OPTIONAL WIPER GASKET (FIELD INSTALLED) CONTINUOUS BUTYL SEALANT DOOR/WINDOW FRAME (NOT BY KINGSPAN) EXPOSED SEALANT (NOT BY KINGSPAN) SILL EXTRUSION FIELD CUT MALE JOINTS WHERE REQUIRED 1 4" - 14 "LOW PROFILE" FASTENERS 1 4" - 14 "LOW PROFILE" THROUGH FASTENERS FRAMED OPENING (NOT BY KINGSPAN) CONTINUOUS BUTYL SEALANT 2", 2.5", 3", OR 4" NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS F.O. SILL WITH EXTRUSION DW-4000 - HORIZONTAL INSTALLATION 2", 2.5", 3", OR 4" PANCAKE FASTENER "LOW PROFILE" 1 4" - 14 HEX HEAD FASTENERS WITH WASHER CONTINUOUS BUTYL SEALANT CONCEALED SOFFIT EXTRUSION FIELD DRILL 3 8 HOLES (NOT BY KINGSPAN) WALL TO SOFFIT 1 2" DW-4000 - HORIZONTAL INSTALLATION 2", 2.5", 3", OR 4" FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW VERTICAL SUPPORT FABLOK FASTENER OR TEK SCREW AT GIRTS FACTORY LONGITUDINAL BEND SUM OF BOTH LEGS NOT TO EXCEED STANDARD PANEL WIDTH NOTE: VERIFY WIND LOADS WITH KINGSPAN PRIOR TO USING EXPANSION FASTENERS FOR PANEL ATTACHMENT LONGITUDINAL BENT SOFFIT DW-4000 - HORIZONTAL INSTALLATION 2", 2.5", 3", OR 4" PANCAKE FASTENER "LOW PROFILE" CONTINUOUS BUTYL SEALANT CONCEALED SOFFIT EXTRUSION FIELD DRILL 3 8 HOLES (NOT BY KINGSPAN) WALL TO FIELD CUT SOFFIT DW-4000 - HORIZONTAL INSTALLATION INTEGRATED PARAPET COPING EXTRUSION SILICONE TUBE SEALANT TYP. STITCH TEKS TO TIE FLASHING IN PLACE FABRICATED METAL FLASHING EXTENSION 3 4" 3" 114" STAINLESS STEEL SCREW PAINTED TO MATCH PANEL. 12" O.C. FASTENING CLIP WITH S.S. BI-METAL TEK 3 SCREW POP RIVETS SILICONE SEALANT 2", 2.5", 3", OR 4" INTEGRATED PARAPET COPING DW-4000 - HORIZONTAL INSTALLATION PARAPET BLOCKING (NOT BY KINGSPAN) FIELD CUT MALE JOINTS WHERE REQUIRED WRAP MEMBRANE (NOT BY KINGSPAN) ADHERE TO EXTERIOR PANEL FACE CONTINUOUS BUTYL SEALANT PARAPET CAP FLASHING 1 4" - 14 "LOW PROFILE" FASTENER FASTENER TO PARAPET BACKER (NOT BY KINGSPAN) CONTINUOUS CLEAT 1 4" - 14 "LOW PROFILE" THROUGH FASTENER PARAPET W/ FLUSH TRIM MEMBRANE ROOF & PARAPET BACKER (NOT BY KINGSPAN) DW-4000 - HORIZONTAL INSTALLATION PARAPET EXTRUSION 1 4" - 14 "LOW PROFILE" THROUGH FASTENERS CONTINUOUS BUTYL SEALANT FIELD CUT MALE JOINTS WHERE REQUIRED WRAP MEMBRANE (NOT BY KINGSPAN) ADHERE TO EXTERIOR PANEL FACE CONTINUOUS BUTYL SEALANT 1 4" - 14 "LOW PROFILE" THROUGH FASTENERS FASTENER TO PARAPET BACKER (NOT BY KINGSPAN) PARAPET CAP TRIM 1 4" - 14 "LOW PROFILE" THROUGH FASTENERS OPTIONAL WIPER GASKET (FIELD INSTALLED) PARAPET W/ FLUSH EXTRUSION MEMBRANE ROOF & PARAPET BACKER (NOT BY KINGSPAN) DW-4000 - HORIZONTAL INSTALLATION KINGSPAN TO SUPPLY FLATSTOCK TO BE FIELD BENT AND BROKE FOR PANEL CLOSURE ATTACH FLATSTOCK WITH POP RIVETS HORIZONTAL PANEL JOINT SILICONE SEALANT AT PERIMETER OF BEAM F.I.P. INSULATION (NOT BY KINGSPAN) FIELD NOTCH PANELS (NOT BY KINGSPAN) POP RIVET FLATSTOCK TO ANGLE SILICONE SEALANT AT PERIMETER OF BEAM WALL PENETRATION SET FLATSTOCK IN BUTYL SEALANT STEEL FRAMING (NOT BY KINGSPAN) ANGLE ATTACHED TO STEEL FRAMING FIELD CUT FLATSTOCK DW-4000 - HORIZONTAL INSTALLATION 'A' TRIM BACKER ROD AND SEALANT (NOT BY KINGSPAN) PENETRATION (NOT BY KINGSPAN) 'A' ELEVATION POP RIVET FASTENER (AS REQUIRED) SEALANT (NOT BY KINGSPAN) FLASHING SEALANT (NOT BY KINGSPAN) BACKER ROD AND SEALANT (NOT BY KINGSPAN) PENETRATION (NOT BY KINGSPAN) SECTION 'A-A' NOTES: 1. DO NOT ALIGN PENETRATIONS AT PANEL JOINT LOCATIONS. 2. FLASHING AT PENETRATIONS TO BE FIELD FABRICATED FROM FLATSTOCK SHEETS AS NECESSARY WALL PENETRATION SECTION DW-4000 - HORIZONTAL INSTALLATION TWO PIECE OPENING EXTRUSION CAP DIE #13943 2" TWO PIECE OPENING EXTRUSION BASE DIE #13939 PARAPET EXTRUSION DIE # 13938 SILL EXTRUSION DIE #13937 2" PANEL CONCEALED BASE EXTRUSION DIE #15849 2" PANEL CONCEALED SOFFIT EXTRUSION DIE #15892 2" CORNER EXTRUSION BASE DIE #14102 2" PANEL PARAPET COPING DIE #15857 CORNER EXTRUSION CAP DIE #14008 VERTICAL JOINT EXTRUSIONS TOP HAT EXTRUSION DIE #13950-A FLUSH INSERT DIE #13951 2" EXTRUSIONS RECESSED TOP HAT EXTRUSION DIE #13949-A RECESSED INSERT DIE #14101 DW-4000 - HORIZONTAL INSTALLATION TWO PIECE OPENING EXTRUSION CAP DIE #13943 2.5" TWO PIECE OPENING EXTRUSION BASE DIE #13940 PARAPET EXTRUSION DIE # 13938 SILL EXTRUSION DIE #13937 2.5" PANEL CONCEALED BASE EXTRUSION DIE #15850 2.5" CORNER EXTRUSION BASE DIE #14103 2.5" PANEL CONCEALED SOFFIT EXTRUSION DIE #15893 2.5" PANEL PARAPET COPING DIE #15858 CORNER EXTRUSION CAP DIE #14008 VERTICAL JOINT EXTRUSIONS TOP HAT EXTRUSION DIE #13950-A FLUSH INSERT DIE #13951 2.5" EXTRUSIONS RECESSED TOP HAT EXTRUSION DIE #13949-A RECESSED INSERT DIE #14101 DW-4000 - HORIZONTAL INSTALLATION TWO PIECE OPENING EXTRUSION CAP DIE #13943 3" TWO PIECE OPENING EXTRUSION BASE DIE #13941 PARAPET EXTRUSION DIE # 13938 SILL EXTRUSION DIE #13937 3" PANEL CONCEALED BASE EXTRUSION DIE # 15851 3" CORNER EXTRUSION BASE DIE #14104 3" PANEL PARAPET COPING DIE #15859 3" PANEL CONCEALED SOFFIT EXTRUSION DIE #15894 CORNER EXTRUSION CAP DIE #14008 VERTICAL JOINT EXTRUSIONS TOP HAT EXTRUSION DIE #13950-A FLUSH INSERT DIE #13951 3" EXTRUSIONS RECESSED TOP HAT EXTRUSION DIE #13949-A RECESSED INSERT DIE #14101 DW-4000 - HORIZONTAL INSTALLATION TWO PIECE OPENING EXTRUSION CAP DIE #13943 4" TWO PIECE OPENING EXTRUSION BASE DIE #13942 PARAPET EXTRUSION DIE # 13938 SILL EXTRUSION DIE #13937 4" PANEL CONCEALED BASE EXTRUSION DIE # 15852 4" PANEL PARAPET COPING DIE #15860 4" PANEL CONCEALED SOFFIT EXTRUSION DIE #15895 4" CORNER EXTRUSION BASE DIE #14105 CORNER EXTRUSION CAP DIE #14008 VERTICAL JOINT EXTRUSIONS TOP HAT EXTRUSION DIE #13950-A FLUSH INSERT DIE #13951 4" EXTRUSIONS RECESSED TOP HAT EXTRUSION DIE #13949-A RECESSED INSERT DIE #14101 DW-4000 - HORIZONTAL INSTALLATION LAP STRIP FOR TWO PIECE JAMB EXTRUSION LAP STRIPS FOR OUTSIDE CORNER EXTRUSION LAP STRIP FOR SILL EXTRUSION EXTRUSION LAP STRIPS LAP STRIP FOR PARAPET EXTRUSION LAP STRIPS FOR INSIDE CORNER EXTRUSION LAP STRIP FOR VERTICAL HAT EXTRUSION DW-4000 - HORIZONTAL INSTALLATION 3" P N. MI LA M I TR (2) BEADS BUTYL SEALANT 3" N. AP I L M IM TR TRIM END LAP DW-4000 - HORIZONTAL INSTALLATION FIELD NOTCH HEM(S) AS REQUIRED (NOT BY KINGSPAN) 3" N. AP I L M IM TR (2) BEADS BUTYL SEALANT 3" N. AP I L M IM TR TRIM LAP WITH HEM DW-4000 - HORIZONTAL INSTALLATION MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT (2) BEADS BUTYL SEALANT MENDING PLATE "SHINGLE" LAP DW-4000 - HORIZONTAL INSTALLATION (2) BEADS BUTYL SEALANT 8" LONG LAP STRIP 1 " . 4 M NO AP G TRIM END LAP WITH LAP STRIP DW-4000 - HORIZONTAL INSTALLATION FIELD NOTCH AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY (NOT BY KINGSPAN) FIELD MITER AND OVERLAP TRIMS, POP RIVET AS NECESSARY (NOT BY KINGSPAN) SEALANT END DAM 2 INTERIOR HEAD TRIM WITH TABS BENT DOWN AD P R RIO CA IM TR E TH A TE IN IM E TH AD A R PT R CA EXTERIOR CAP TRIM AT JAMB T EX IO ER 5 EXTERIOR HEAD TRIM W/ FIELD DRILL 3 8 (NOT BY KINGSPAN) 1 INTERIOR JAMB TRIM 6 EXPOSED SEALANT (NOT BY KINGSPAN) 3 SILL TRIM WITH TABS BENT UP RI R 4 EXTERIOR JAMB TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP (NOT BY KINGSPAN) ILL O RI FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP (NOT BY KINGSPAN) T AP M C TE EX TRIM AT FRAMED OPENINGS S AT FIELD MITER AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY (NOT BY KINGSPAN) TRIM INSTALLATION SEQUENCE: 1 INTERIOR JAMB TRIM 2 INTERIOR HEAD TRIM WITH TABS DOWN 3 SILL TRIM WITH TABS UP 4 EXTERIOR JAMB TRIM 5 EXTERIOR HEAD TRIM 6 EXTERIOR SEALANTS AS REQUIRED DW-4000 - HORIZONTAL INSTALLATION FIELD CUT/NOTCH JAMB EXTRUSION AT HEAD AND JAMB (NOT BY KINGSPAN) SEALANT END DAM TWO PIECE HEAD EXTRUSION CAP 3 EXPOSED SEALANT (NOT BY KINGSPAN) N SIO U TR CE O TW PIE 2 TWO PIECE HEAD EXTRUSION BASE W/ FIELD DRILL 3 8 (NOT BY KINGSPAN) 1 TWO PIECE JAMB EXTRUSION BASE 6 EXPOSED SEALANT (NOT BY KINGSPAN) TWO PIECE JAMB EXTRUSION X DE A HE 4 FIELD CUT/NOTCH JAMB EXTRUSION (NOT BY KINGSPAN) 5 ON TR EX L IL I US S EXTRUSION AT FRAMED OPENING TWO PIECE JAMB EXTRUSION CAP TWO PIECE JAMB EXTRUSION CAP EXTRUSION INSTALLATION SEQUENCE: 1 TWO PIECE JAMB EXTRUSION BASE 2 TWO PIECE HEAD EXTRUSION BASE 3 TWO PIECE HEAD EXTRUSION CAP 4 TWO PIECE JAMB EXTRUSION CAP 5 SILL EXTRUSION 6 EXTERIOR SEALANTS AS REQUIRED DW-4000 - HORIZONTAL INSTALLATION FASTENING CLIP VJ-1 2" OR 3" FLAT PANEL VJ-2 2" RIBBED PANEL 3" RIBBED PANEL VERTICAL JOINT GASKET GASKET AVAILABLE IN BLACK OR LIGHT GRAY ACCESSORIES