DW-4000 - HORIZONTAL INSTALLATION
AR-PJ-01-DW4H
AR-PJ-02-DW4H
AR-PJ-03-DW4H
AR-PJ-04-DW4H
AR-PJ-05-DW4H
AR-PJ-06-DW4H
AR-PJ-07-DW4H
AR-PJ-08-DW4H
AR-PJ-09-DW4H
AR-PJ-10-DW4H
AR-PJ-11-DW4H
AR-PJ-12-DW4H
AR-PJ-13-DW4H
AR-PJ-14-DW4H
AR-PJ-15-DW4H
AR-BS-01-DW4H
AR-BS-02-DW4H
AR-BS-03-DW4H
AR-BS-04-DW4H
AR-OC-01-DW4H
AR-OC-02-DW4H
AR-OC-03-DW4H
AR-OC-04-DW4H
AR-IC-01-DW4H
AR-IC-02-DW4H
AR-IC-03-DW4H
2" HORIZONTAL PANEL JOINT
2" PANEL VERTICAL REVEAL
212" HORIZONTAL PANEL JOINT
212" PANEL VERTICAL REVEAL
3" HORIZONTAL PANEL JOINT
3" PANEL VERTICAL REVEAL
4" HORIZONTAL PANEL JOINT
4" PANEL VERTICAL REVEAL
CUSTOM REVEAL
DW-4000S PANEL PROFILE
DW-4000H TO DW-4000V TRANSITION
VERTICAL REVEAL W/ EXTRUSION
PANELS OVER STRUCTURAL STEEL
PANELS OVER METAL STUDS
PANELS OVER CONCRETE
BASE DETAIL - FLUSH
BASE DETAIL - OVERHANG
BASE DETAIL AT VERTICAL JOINT (FLUSH)
BASE DETAIL AT VERTICAL JNT. (OVERHANG)
TRANSVERSE BENT CORNER
OUTSIDE CORNER WITH EXTRUSION
OUTSIDE CORNER WITH FLAT TRIM
INSIDE CORNER WITH EXTRUSION
INSIDE CORNER WITH TRIMLESS ENDS
INSIDE CORNER WITH FLUSH TRIM
INDEX SHEET 1
DW-4000 - HORIZONTAL INSTALLATION
AR-FO-04-DW4H
AR-FO-05-DW4H
AR-FO-06-DW4H
AR-FO-07-DW4H
AR-FO-08-DW4H
AR-FO-09-DW4H
AR-FO-10-DW4H
AR-FO-11-DW4H
AR-SF-01-DW4H
AR-SF-02-DW4H
AR-SF-03-DW4H
AR-PR-01-DW4H
AR-PR-02-DW4H
AR-PR-03-DW4H
AR-TL-01-DW4H
AR-TL-02-DW4H
AR-TL-03-DW4H
AR-TL-03B-DW4H
AR-TL-04-DW4H
AR-TL-04B-DW4H
AR-TL-05-DW4H
AR-TL-06-DW4H
AR-TL-07-DW4H
AR-TL-08-DW4H
AR-TL-09-DW4H
AR-TL-10-DW4H
AR-TL-11-DW4H
AR-TL-12-DW4H
F.O. TWO PIECE HEAD
F.O. HEAD WITH DRIP EDGE
F.O. TWO PIECE JAMB
F.O. ONE PIECE JAMB
F.O. ONE PIECE SILL
F.O. HEADER WITH EXTRUSION
F.O. JAMB WITH EXTRUSION
F.O. SILL WITH EXTRUSION
WALL TO SOFFIT
LONGITUDINAL BENT SOFFIT
WALL TO FIELD CUT SOFFIT
INTEGRATED PARAPET COPING
PARAPET W/ FLUSH TRIM
PARAPET W/ FLUSH EXTRUSION
WALL PENETRATION
WALL PENETRATION SECTION
2" EXTRUSIONS
212" EXTRUSIONS
3" EXTRUSIONS
4" EXTRUSIONS
EXTRUSION LAP STRIPS
TRIM END LAP
TRIM LAP WITH HEM
MENDING PLATE "SHINGLE" LAP
TRIM END LAP WITH LAP STRIP
TRIM AT FRAMED OPENINGS
EXTRUSION AT FRAMED OPENING
ACCESSORIES
INDEX SHEET 2
DW-4000 - HORIZONTAL INSTALLATION
DISCLAIMERS:
THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED
COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.
LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED
ON TYPICAL DESIGN PRACTICES FOR MOST U.S. CLIMACTIC ZONES. (THE PRIMARY VAPOR
BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER).
CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
EXTRUSION SHAPES / ENGAGEMENT MAY VARY FROM THOSE SHOWN.
PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY
REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT RECOMMENDATIONS.
ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION
PURPOSES ONLY.
ARCHITECTURAL
DISCLAIMER
24", 30" OR 36" MODULE
STANDARD INTERLOCK
JOINT FINNED GASKET
FACE OF
PANEL
FACE SHEET WEDGE GASKET
REVEAL
S.S. BI-METAL TEK 3 SCREW
2"
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
1
DIRECTION OF INSTALLATION
DW-4000 - HORIZONTAL INSTALLATION
VERTICAL SUPPORTS
BY OTHERS
2"
FASTENING CLIP
CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
2" HORIZONTAL
PANEL JOINT
DW-4000 - HORIZONTAL INSTALLATION
6" RECOMMENDED BEARING
FRAMING
BY OTHERS
CONTINUOUS
MENDING PLATE
2"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
1
2"
VERTICAL JOINT GASKET
PANEL LENGTH MEASURED FROM HERE
2" PANEL VERTICAL
REVEAL
PANEL LENGTH MEASURED FROM HERE
24", 30" OR 36" MODULE
FACE OF
PANEL
STANDARD INTERLOCK
JOINT FINNED GASKET
FACE SHEET WEDGE GASKET
REVEAL
S.S. BI-METAL TEK 3 SCREW
2"
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
1
DIRECTION OF INSTALLATION
DW-4000 - HORIZONTAL INSTALLATION
VERTICAL SUPPORTS
BY OTHERS
212"
FASTENING CLIP
CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
212" HORIZONTAL
PANEL JOINT
DW-4000 - HORIZONTAL INSTALLATION
6" RECOMMENDED BEARING
FILL VOID WITH COMPRESSIBLE
FOAM CLOSURE
FRAMING
BY OTHERS
CONTINUOUS
MENDING PLATE
212"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
1
2"
VERTICAL JOINT GASKET
PANEL LENGTH MEASURED FROM HERE
212" PANEL VERTICAL
REVEAL
PANEL LENGTH MEASURED FROM HERE
DW-4000 - HORIZONTAL INSTALLATION
24", 30" OR 36" MODULE
FACE OF
PANEL
STANDARD INTERLOCK
JOINT FINNED GASKET
REVEAL
S.S. BI-METAL TEK 3 SCREW
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
1
2"
DIRECTION OF INSTALLATION
FACE SHEET WEDGE GASKET
VERTICAL SUPPORTS
BY OTHERS
3"
FASTENING CLIP
CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
3" HORIZONTAL
PANEL JOINT
DW-4000 - HORIZONTAL INSTALLATION
6" RECOMMENDED BEARING
FILL VOID WITH COMPRESSIBLE
FOAM CLOSURE
FRAMING
BY OTHERS
CONTINUOUS
MENDING PLATE
3"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
1
2"
VERTICAL JOINT GASKET
PANEL LENGHT MEASURED FROM HERE
3" PANEL VERTICAL
REVEAL
PANEL LENGTH MEASURED FROM HERE
DW-4000 - HORIZONTAL INSTALLATION
24", 30" OR 36" MODULE
FACE OF
PANEL
STANDARD INTERLOCK
JOINT FINNED GASKET
REVEAL
S.S. BI-METAL TEK 3 SCREW
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
1
2"
DIRECTION OF INSTALLATION
FACE SHEET WEDGE GASKET
VERTICAL SUPPORTS
BY OTHERS
4"
FASTENING CLIP
CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
4" HORIZONTAL
PANEL JOINT
DW-4000 - HORIZONTAL INSTALLATION
6" RECOMMENDED BEARING
FILL VOID WITH COMPRESSIBLE
FOAM CLOSURE
FRAMING
BY OTHERS
CONTINUOUS
MENDING PLATE
4"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
1
2"
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
VERTICAL JOINT GASKET
PANEL LENGHT MEASURED FROM HERE
4" PANEL VERTICAL
REVEAL
PANEL LENGTH MEASURED FROM HERE
PANEL MODULE
DW-4000 - HORIZONTAL INSTALLATION
FACE OF
PANEL
6" MAX.
11 "
16
S.S. BI-METAL TEK 3 SCREW
S.S. FATENING CLIP WITH
PVC FOAM TAPE STRIP SEAL
REVEAL MODIFICATION
BUILT INTO LOWER PANEL
VERTICAL
SUPPORT
BY OTHERS
FASTENING CLIP
NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED AT TERMINATIONS
CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
CUSTOM REVEAL
DW-4000S - HORIZONTAL INSTALLATION
STANDARD INTERLOCK
JOINT FINNED GASKET
REVEAL
FACE SHEET WEDGE GASKET
114" STRIATION PITCH
24", 30", OR 36" MODULE STANDARD
FACE OF PANEL
STRIATED FACE SHEET
STRIATION DEPTH
.035 INCH
2", 2.5", 3", OR 4"
DW-4000S PANEL
PROFILE
DW-4000 - HORIZONTAL INSTALLATION
6" RECOMMENDED BEARING
FRAMING
BY OTHERS
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
MODIFIED EDGE ON
VERTICAL PANEL
2 - PC FASTENING CLIP WITH
4" - 14 HEX HEAD FASTENERS
WITHOUT WASHER
2" OR 3"
1
DESIGNWALL
4000H PANEL
DESIGNWALL
4000V PANEL
VERTICAL JOINT GASKET
1
HORIZONTAL PANEL LENGTH MEASURED HERE
DW-4000H TO
DW-4000V TRANSITION
2"
VERTICAL PANEL LENGTH MEASURED HERE
DW-4000 - HORIZONTAL INSTALLATION
6" RECOMMENDED BEARING
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
16 GAUGE MENDING PLATE
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
2" OR 3"
FRAMING
BY OTHERS
BLACK EPDM GASKET
7
8"
3
4"
7
8"
212"
PLUG ENDS OF HORIZ.
JOINTS WITH SILICONE
SEALANT*
PVC FOAM GASKET
ALUMINUM TOP HAT
JOINT EXTRUSION
ALUMINUM JOINT EXTRUSION ALTERNATIVES
ALUMINUM FLUSH INSERT
ALUMINUM RECESSED INSERT
*NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED AT TERMINATIONS
VERTICAL REVEAL W/
EXTRUSION
DW-4000 - HORIZONTAL INSTALLATION
ALWAYS ATTACH HORIZONTAL PANELS TO
VERTICALLY ORIENTED SUPPORTS
VERTICAL TUBES
VERTICAL TUBES
HORIZONTAL
PANELS
PANELS OVER
STRUCTURAL STEEL
DW-4000 - HORIZONTAL INSTALLATION
ALWAYS ATTACH HORIZONTAL PANELS TO
VERTICALLY ORIENTED SUPPORTS
VERTICAL
STUDS
HORIZONTAL
PANELS
PANELS OVER METAL
STUDS
SHEATHING
OPTIONAL
DW-4000 - HORIZONTAL INSTALLATION
ALWAYS ATTACH HORIZONTAL PANELS TO
VERTICALLY ORIENTED SUPPORTS
VERTICAL
SUBGIRTS
HORIZONTAL
PANELS
PRECAST OR
CMU WALL
PANELS OVER
CONCRETE
DW-4000 - HORIZONTAL INSTALLATION
2", 2.5", 3", OR 4"
CONTINUOUS
BUTYL SEALANT
1
4"-14 "LOW PROFILE"
FASTENERS
CONCEALED BASE
EXTRUSION
FIELD DRILL 3 8
WEEP HOLES
(NOT BY KINGSPAN)
BED SEAL TO CONCRETE
FABRICATED BASE TRIM
BASE DETAIL - FLUSH
DW-4000 - HORIZONTAL INSTALLATION
2", 2.5", 3", OR 4"
CONTINUOUS BUTYL
SEALANT
CONCEALED BASE
EXTRUSION
FIELD DRILL 3 8
WEEP HOLES
(NOT BY KINGSPAN)
BASE DETAIL OVERHANG
1
4"-14 "LOW PROFILE"
FASTENER
DW-4000 - HORIZONTAL INSTALLATION
6"
RE
C.
VERTICAL JOINT GASKET (SHOWN)
OR FIELD APPLIED BACKER
ROD AND SEALANT
CONTINUOUS MENDING
PLATE
BUTYL SEALANT
CONTINUOUS BEADS
"SHINGLE" LAP MENDING PLATE
OVER FLASHING.
SEE AR-TL-08-DW4H
FLASHING BEHIND AND UNDER
BASE EXTRUSION
BASE EXTRUSION
W/ BUTYL SEALANT
BELOW
STOP EXTRUSION SHORT
OF PANEL EDGE
MARRIAGE BEAD TO
JOINT SEALANT
BASE DETAIL AT
VERTICAL JOINT
(FLUSH)
SEALANT
(NOT BY KINGSPAN)
DW-4000 - HORIZONTAL INSTALLATION
5"
RE
C
.
VERTICAL JOINT GASKET (SHOWN)
OR FIELD APPLIED BACKER
ROD AND SEALANT
CONTINUOUS MENDING
PLATE
BUTYL SEALANT
CONTINUOUS BEADS
FLASHING BEHIND
BASE EXTRUSION
W/ BUTYL SEALANT
BELOW
STOP EXTRUSION SHORT
OF PANEL EDGE
MARRIAGE BEAD TO
JOINT SEALANT
BASE DETAIL AT
VERTICAL JOINT
(OVERHANG)
SEALANT
(NOT BY KINGSPAN)
DW-4000 - HORIZONTAL INSTALLATION
2", 2.5", 3", OR 4"
FRAMING BY OTHERS
CONTINUOUS
MENDING PLATE
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
FACTORY TRANSVERSE BEND
SHORT LEG 4'-0 MAXIMUM, TOTAL LENGTH 14'-0 MAX.
TRANSVERSE BENT
CORNER
DW-4000 - HORIZONTAL INSTALLATION
2", 2.5", 3", OR 4"
FRAMING BY OTHERS
PANEL LENGTH
CONTINUOUS
MENDING PLATE
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
3
8"
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
3
PANEL LENGTH
8"
1
2"
VERTICAL JOINT GASKET
DW-4000 - HORIZONTAL INSTALLATION
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
,
2"
,3
5"
2.
",
R
O
4"
FIELD CUT
PANELS TO SUIT
PLUG ENDS OF
HORIZONTAL
JOINTS WITH
SILICONE
SEALANT*
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
3"
3"
2-PC ARROWHEAD
OUTSIDE CORNER
EXTRUSION
OPTIONAL WIPER GASKET
(FIELD INSTALLED)
*NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED
OUTSIDE CORNER
WITH EXTRUSION
DW-4000 - HORIZONTAL INSTALLATION
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
INSIDE CORNER TRIM
,2
2"
",
,3
"
.5
O
R
4"
VERTICAL SUPPORT
POP RIVETS
PLUG ENDS OF
HORIZONTAL JOINTS
WITH SILICONE
SEALANT*
F.I.P. INSULATION
AS REQUIRED
(BY OTHERS)
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
OUTSIDE CORNER TRIM
FIELD MITER
PANELS
*NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED
OUTSIDE CORNER
WITH FLAT TRIM
DW-4000 - HORIZONTAL INSTALLATION
OPTIONAL WIPER GASKET
(FIELD INSTALLED)
1
4"
- 14 "LOW PROFILE"
FASTENER
FIELD CUT
PANELS TO SUIT
CONTINUOUS
BUTYL SEALANT
WITH MARRIAGE
BEAD TO
HORIZONTAL
PANEL JOINT
VERTICAL SUPPORT
2-PC ARROWHEAD
OUTSIDE CORNER
EXTRUSION
R
5
,
2"
PLUG ENDS OF HORIZONTAL
JOINTS WITH SILICONE SEALANT*
2.
3
",
",
4"
O
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
*NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED
INSIDE CORNER
WITH EXTRUSION
DW-4000 - HORIZONTAL INSTALLATION
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
FRAMING BY OTHERS
CONTINUOUS
MENDING PLATE
PLUG ENDS OF
HORIZONTAL
JOINTS WITH
SILICONE
SEALANT*
1
2"
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
VERTICAL JOINT GASKET
2", 2.5", 3", OR 4"
*NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED
INSIDE CORNER W/
TRIMLESS ENDS
DW-4000 - HORIZONTAL INSTALLATION
F.I.P. INSULATION AS REQUIRED
(BY OTHERS)
VERTICAL SUPPORT
OUTSIDE CORNER TRIM
2", 2.5", 3", OR 4"
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
HORIZONTAL PANEL JOINT
INSIDE CORNER TRIM
POP RIVETS
PLUG ENDS OF
HORIZONTAL JOINTS WITH
SILICONE SEALANT*
*NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED
INSIDE CORNER WITH
FLUSH TRIM
DW-4000 - HORIZONTAL INSTALLATION
CONTINUOUS BUTYL SEALANT
1
INTERIOR CAP TRIM
4"
- 14 "LOW PROFILE"
THROUGH FASTENER
CONTINUOUS
BUTYL SEALANT
POP RIVETS
EXTERIOR CAP TRIM
FRAMED OPENING
(NOT BY KINGSPAN)
FIELD DRILL 3 8
(NOT BY KINGSPAN)
FIELD CUT FEMALE JOINTS
WHERE REQUIRED
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H
FOR TYPICAL TRIM LAP INSTRUCTIONS
2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED
WINDOW DESIGNS
F.O. TWO PIECE HEAD
DW-4000 - HORIZONTAL INSTALLATION
CONTINUOUS BUTYL SEALANT
1
4" - 14 "LOW PROFILE"
THROUGH FASTENERS
CONTINUOUS
BUTYL SEALANT
POP RIVETS
EXTERIOR CAP TRIM
FRAMED OPENING
(NOT BY KINGSPAN)
DRIP FLASHING
FIELD CUT FEMALE JOINTS
WHERE REQUIRED
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H
FOR TYPICAL TRIM LAP INSTRUCTIONS
2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED
WINDOW DESIGNS
F.O. HEAD WITH DRIP
EDGE
DW-4000 - HORIZONTAL INSTALLATION
FRAMED OPENING
(NOT BY KINGSPAN)
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
INTERIOR CAP TRIM
EXPOSED SEALANT
(NOT BY KINGSPAN)
POP RIVETS
FIELD CUT PANELS WHERE
REQUIRED
CONTINUOUS BUTYL SEALANT WITH
MARRIAGE BEAD TO HORIZONTAL
PANEL JOINT
EXTERIOR CAP TRIM
PLUG ENDS OF HORIZONTAL
JOINTS WITH SILICONE SEALANT*
POP RIVETS
NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H
FOR TYPICAL TRIM LAP INSTRUCTIONS
2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED
WINDOW DESIGNS
3) FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED
F.O. TWO PIECE JAMB
DW-4000 - HORIZONTAL INSTALLATION
FRAMED OPENING
(NOT BY KINGSPAN)
1
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
4" - 14 "LOW PROFILE"
FASTENERS (AS REQUIRED)
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO HORIZONTAL
PANEL JOINT
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
CONTINUOUS BUTYL
SEALANT
EXPOSED SEALANT
(NOT BY KINGSPAN)
FIELD CUT PANELS WHERE
REQUIRED
POP RIVETS
CAP TRIM
PLUG ENDS OF HORIZONTAL
JOINTS WITH SILICONE SEALANT*
NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H
FOR TYPICAL TRIM LAP INSTRUCTIONS
2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED
WINDOW DESIGNS
3) FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED
F.O. ONE PIECE JAMB
DW-4000 - HORIZONTAL INSTALLATION
CONTINUOUS BUTYL
SEALANT
EXPOSED SEALANT
(NOT BY KINGSPAN)
WINDOW FRAME
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
FIELD CUT MALE JOINTS
WHERE REQUIRED
EXTERIOR CAP TRIM
POP RIVETS
FIELD BEND
(AS REQUIRED)
1
4" - 14 "LOW PROFILE"
THROUGH FASTENERS
1
4" - 14 "LOW PROFILE"
FASTENERS (AS REQUIRED)
FRAMED OPENING
(NOT BY KINGSPAN)
NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H
FOR TYPICAL TRIM LAP INSTRUCTIONS
2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED
WINDOW DESIGNS
F.O. ONE PIECE SILL
DW-4000 - HORIZONTAL INSTALLATION
2", 2.5", 3", OR 4"
CONTINUOUS BUTYL SEALANT
1
4" - 14 "LOW PROFILE"
THROUGH FASTENERS
1
4" - 14 "LOW PROFILE"
FASTENERS
TWO PIECE HEAD
EXTRUSION CAP
CONTINUOUS BUTYL SEALANT
FRAMED OPENING
(NOT BY KINGSPAN)
FIELD DRILL 3 8
(NOT BY KINGSPAN)
FIELD CUT FEMALE JOINTS
WHERE REQUIRED
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
TWO PIECE HEAD
EXTRUSION BASE
EXPOSED SEALANT
(NOT BY KINGSPAN)
OPTIONAL WIPER
GASKET
(FIELD INSTALLED)
NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H
FOR TYPICAL TRIM LAP INSTRUCTIONS
2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED
WINDOW DESIGNS
F.O. HEADER WITH
EXTRUSION
DW-4000 - HORIZONTAL INSTALLATION
OPTIONAL WIPER
GASKET
(FIELD INSTALLED)
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
FRAMED OPENING
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
2", 2.5", 3", OR 4"
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO HORIZONTAL
PANEL JOINT
TWO PIECE JAMB
EXTRUSION BASE
FIELD CUT PANELS WHERE
REQUIRED
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
TWO PIECE JAMB
EXTRUSION CAP
PLUG ENDS OF HORIZONTAL
JOINTS WITH SILICONE
SEALANT*
NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H
FOR TYPICAL TRIM LAP INSTRUCTIONS
2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED
WINDOW DESIGNS
3) FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED
F.O. JAMB WITH
EXTRUSION
DW-4000 - HORIZONTAL INSTALLATION
OPTIONAL WIPER
GASKET
(FIELD INSTALLED)
CONTINUOUS BUTYL SEALANT
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
SILL EXTRUSION
FIELD CUT MALE JOINTS
WHERE REQUIRED
1
4" - 14 "LOW PROFILE"
FASTENERS
1
4" - 14 "LOW PROFILE"
THROUGH FASTENERS
FRAMED OPENING
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
2", 2.5", 3", OR 4"
NOTE: 1) SEE DETAIL AR-TL-07-DW4H, AR-TL-08-DW4H, AND AR-TL-10-DW4H
FOR TYPICAL TRIM LAP INSTRUCTIONS
2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED
WINDOW DESIGNS
F.O. SILL WITH
EXTRUSION
DW-4000 - HORIZONTAL INSTALLATION
2", 2.5", 3", OR 4"
PANCAKE FASTENER
"LOW PROFILE"
1
4" - 14 HEX HEAD
FASTENERS WITH
WASHER
CONTINUOUS BUTYL
SEALANT
CONCEALED SOFFIT
EXTRUSION
FIELD DRILL 3 8
HOLES (NOT BY KINGSPAN)
WALL TO SOFFIT
1
2"
DW-4000 - HORIZONTAL INSTALLATION
2", 2.5", 3", OR 4"
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
VERTICAL SUPPORT
FABLOK FASTENER
OR TEK SCREW AT
GIRTS
FACTORY LONGITUDINAL BEND
SUM OF BOTH LEGS NOT TO
EXCEED STANDARD PANEL WIDTH
NOTE: VERIFY WIND LOADS WITH KINGSPAN PRIOR TO USING
EXPANSION FASTENERS FOR PANEL ATTACHMENT
LONGITUDINAL BENT
SOFFIT
DW-4000 - HORIZONTAL INSTALLATION
2", 2.5", 3", OR 4"
PANCAKE FASTENER
"LOW PROFILE"
CONTINUOUS BUTYL
SEALANT
CONCEALED SOFFIT
EXTRUSION
FIELD DRILL 3 8
HOLES (NOT BY KINGSPAN)
WALL TO FIELD CUT
SOFFIT
DW-4000 - HORIZONTAL INSTALLATION
INTEGRATED PARAPET COPING EXTRUSION
SILICONE TUBE SEALANT TYP.
STITCH TEKS TO TIE
FLASHING IN PLACE
FABRICATED METAL
FLASHING EXTENSION
3
4"
3"
114"
STAINLESS STEEL SCREW PAINTED
TO MATCH PANEL. 12" O.C.
FASTENING CLIP WITH
S.S. BI-METAL TEK 3 SCREW
POP RIVETS
SILICONE SEALANT
2", 2.5", 3", OR 4"
INTEGRATED PARAPET
COPING
DW-4000 - HORIZONTAL INSTALLATION
PARAPET BLOCKING
(NOT BY KINGSPAN)
FIELD CUT MALE JOINTS
WHERE REQUIRED
WRAP MEMBRANE
(NOT BY KINGSPAN)
ADHERE TO EXTERIOR
PANEL FACE
CONTINUOUS
BUTYL SEALANT
PARAPET CAP
FLASHING
1
4" - 14 "LOW PROFILE"
FASTENER
FASTENER TO PARAPET
BACKER (NOT BY KINGSPAN)
CONTINUOUS CLEAT
1
4" - 14 "LOW PROFILE"
THROUGH FASTENER
PARAPET W/ FLUSH
TRIM
MEMBRANE ROOF &
PARAPET BACKER
(NOT BY KINGSPAN)
DW-4000 - HORIZONTAL INSTALLATION
PARAPET EXTRUSION
1
4" - 14 "LOW PROFILE"
THROUGH FASTENERS
CONTINUOUS
BUTYL SEALANT
FIELD CUT MALE JOINTS
WHERE REQUIRED
WRAP MEMBRANE
(NOT BY KINGSPAN)
ADHERE TO EXTERIOR
PANEL FACE
CONTINUOUS
BUTYL SEALANT
1
4" - 14 "LOW PROFILE"
THROUGH FASTENERS
FASTENER TO PARAPET
BACKER (NOT BY KINGSPAN)
PARAPET CAP TRIM
1
4" - 14 "LOW PROFILE"
THROUGH FASTENERS
OPTIONAL WIPER
GASKET
(FIELD INSTALLED)
PARAPET W/ FLUSH
EXTRUSION
MEMBRANE ROOF &
PARAPET BACKER
(NOT BY KINGSPAN)
DW-4000 - HORIZONTAL INSTALLATION
KINGSPAN TO SUPPLY FLATSTOCK
TO BE FIELD BENT AND BROKE
FOR PANEL CLOSURE
ATTACH FLATSTOCK WITH
POP RIVETS
HORIZONTAL PANEL
JOINT
SILICONE SEALANT
AT PERIMETER OF BEAM
F.I.P. INSULATION
(NOT BY KINGSPAN)
FIELD NOTCH PANELS
(NOT BY KINGSPAN)
POP RIVET FLATSTOCK
TO ANGLE
SILICONE SEALANT
AT PERIMETER OF BEAM
WALL PENETRATION
SET FLATSTOCK
IN BUTYL SEALANT
STEEL FRAMING
(NOT BY KINGSPAN)
ANGLE ATTACHED TO
STEEL FRAMING
FIELD CUT FLATSTOCK
DW-4000 - HORIZONTAL INSTALLATION
'A'
TRIM
BACKER ROD AND
SEALANT
(NOT BY KINGSPAN)
PENETRATION
(NOT BY KINGSPAN)
'A'
ELEVATION
POP RIVET
FASTENER
(AS REQUIRED)
SEALANT
(NOT BY KINGSPAN)
FLASHING
SEALANT
(NOT BY KINGSPAN)
BACKER ROD AND
SEALANT
(NOT BY KINGSPAN)
PENETRATION
(NOT BY KINGSPAN)
SECTION 'A-A'
NOTES: 1. DO NOT ALIGN PENETRATIONS AT PANEL JOINT LOCATIONS.
2. FLASHING AT PENETRATIONS TO BE FIELD FABRICATED FROM
FLATSTOCK SHEETS AS NECESSARY
WALL PENETRATION
SECTION
DW-4000 - HORIZONTAL INSTALLATION
TWO PIECE OPENING
EXTRUSION CAP
DIE #13943
2" TWO PIECE OPENING
EXTRUSION BASE
DIE #13939
PARAPET EXTRUSION
DIE # 13938
SILL EXTRUSION
DIE #13937
2" PANEL CONCEALED
BASE EXTRUSION DIE
#15849
2" PANEL CONCEALED
SOFFIT EXTRUSION
DIE #15892
2" CORNER
EXTRUSION BASE
DIE #14102
2" PANEL PARAPET
COPING DIE #15857
CORNER
EXTRUSION CAP
DIE #14008
VERTICAL JOINT EXTRUSIONS
TOP HAT EXTRUSION
DIE #13950-A
FLUSH INSERT
DIE #13951
2" EXTRUSIONS
RECESSED
TOP HAT EXTRUSION
DIE #13949-A
RECESSED
INSERT
DIE #14101
DW-4000 - HORIZONTAL INSTALLATION
TWO PIECE OPENING
EXTRUSION CAP
DIE #13943
2.5" TWO PIECE OPENING
EXTRUSION BASE
DIE #13940
PARAPET EXTRUSION
DIE # 13938
SILL EXTRUSION
DIE #13937
2.5" PANEL CONCEALED
BASE EXTRUSION DIE
#15850
2.5" CORNER
EXTRUSION BASE
DIE #14103
2.5" PANEL CONCEALED
SOFFIT EXTRUSION
DIE #15893
2.5" PANEL PARAPET
COPING DIE #15858
CORNER
EXTRUSION CAP
DIE #14008
VERTICAL JOINT EXTRUSIONS
TOP HAT EXTRUSION
DIE #13950-A
FLUSH INSERT
DIE #13951
2.5" EXTRUSIONS
RECESSED
TOP HAT EXTRUSION
DIE #13949-A
RECESSED
INSERT
DIE #14101
DW-4000 - HORIZONTAL INSTALLATION
TWO PIECE OPENING
EXTRUSION CAP
DIE #13943
3" TWO PIECE OPENING
EXTRUSION BASE
DIE #13941
PARAPET EXTRUSION
DIE # 13938
SILL EXTRUSION
DIE #13937
3" PANEL CONCEALED BASE
EXTRUSION DIE # 15851
3" CORNER
EXTRUSION BASE
DIE #14104
3" PANEL PARAPET
COPING DIE #15859
3" PANEL CONCEALED
SOFFIT EXTRUSION
DIE #15894
CORNER
EXTRUSION CAP
DIE #14008
VERTICAL JOINT EXTRUSIONS
TOP HAT EXTRUSION
DIE #13950-A
FLUSH INSERT
DIE #13951
3" EXTRUSIONS
RECESSED
TOP HAT EXTRUSION
DIE #13949-A
RECESSED
INSERT
DIE #14101
DW-4000 - HORIZONTAL INSTALLATION
TWO PIECE OPENING
EXTRUSION CAP
DIE #13943
4" TWO PIECE OPENING
EXTRUSION BASE
DIE #13942
PARAPET EXTRUSION
DIE # 13938
SILL EXTRUSION
DIE #13937
4" PANEL CONCEALED BASE
EXTRUSION DIE # 15852
4" PANEL PARAPET
COPING DIE #15860
4" PANEL CONCEALED
SOFFIT EXTRUSION
DIE #15895
4" CORNER
EXTRUSION BASE
DIE #14105
CORNER
EXTRUSION CAP
DIE #14008
VERTICAL JOINT EXTRUSIONS
TOP HAT EXTRUSION
DIE #13950-A
FLUSH INSERT
DIE #13951
4" EXTRUSIONS
RECESSED
TOP HAT EXTRUSION
DIE #13949-A
RECESSED
INSERT
DIE #14101
DW-4000 - HORIZONTAL INSTALLATION
LAP STRIP FOR TWO PIECE
JAMB EXTRUSION
LAP STRIPS FOR OUTSIDE CORNER
EXTRUSION
LAP STRIP FOR SILL EXTRUSION
EXTRUSION LAP
STRIPS
LAP STRIP FOR PARAPET EXTRUSION
LAP STRIPS FOR INSIDE CORNER
EXTRUSION
LAP STRIP FOR VERTICAL HAT EXTRUSION
DW-4000 - HORIZONTAL INSTALLATION
3"
P
N.
MI LA
M
I
TR
(2) BEADS
BUTYL SEALANT
3"
N. AP
I
L
M
IM
TR
TRIM END LAP
DW-4000 - HORIZONTAL INSTALLATION
FIELD NOTCH HEM(S)
AS REQUIRED
(NOT BY KINGSPAN)
3"
N. AP
I
L
M
IM
TR
(2) BEADS
BUTYL SEALANT
3"
N. AP
I
L
M
IM
TR
TRIM LAP WITH HEM
DW-4000 - HORIZONTAL INSTALLATION
MIN. 3"
TRIM LAP
(2) BEADS
BUTYL SEALANT
(2) BEADS
BUTYL SEALANT
MENDING PLATE
"SHINGLE" LAP
DW-4000 - HORIZONTAL INSTALLATION
(2) BEADS
BUTYL SEALANT
8" LONG LAP STRIP
1 "
. 4
M
NO AP
G
TRIM END LAP WITH
LAP STRIP
DW-4000 - HORIZONTAL INSTALLATION
FIELD NOTCH AND OVERLAP
TRIMS, POP RIVET AND SEAL AS
NECESSARY (NOT BY KINGSPAN)
FIELD MITER AND OVERLAP
TRIMS, POP RIVET AS
NECESSARY (NOT BY KINGSPAN)
SEALANT END DAM
2
INTERIOR HEAD TRIM
WITH TABS BENT DOWN
AD
P
R
RIO
CA
IM
TR
E
TH
A
TE
IN
IM
E
TH
AD
A
R
PT
R
CA
EXTERIOR CAP TRIM AT JAMB
T
EX
IO
ER
5
EXTERIOR HEAD TRIM W/
FIELD DRILL 3 8
(NOT BY KINGSPAN)
1
INTERIOR JAMB TRIM
6
EXPOSED SEALANT
(NOT BY KINGSPAN)
3
SILL TRIM WITH TABS
BENT UP
RI
R
4
EXTERIOR JAMB TRIM
FIELD CUT/NOTCH CAP
TRIM AT CORNERS TO
ALLOW FOR LAP
(NOT BY KINGSPAN)
ILL
O
RI
FIELD CUT/NOTCH CAP
TRIM AT CORNERS TO
ALLOW FOR LAP
(NOT BY KINGSPAN)
T
AP
M
C
TE
EX
TRIM AT FRAMED
OPENINGS
S
AT
FIELD MITER AND OVERLAP
TRIMS, POP RIVET AND SEAL AS
NECESSARY (NOT BY KINGSPAN)
TRIM INSTALLATION SEQUENCE:
1
INTERIOR JAMB TRIM
2
INTERIOR HEAD TRIM WITH TABS DOWN
3
SILL TRIM WITH TABS UP
4
EXTERIOR JAMB TRIM
5
EXTERIOR HEAD TRIM
6
EXTERIOR SEALANTS AS REQUIRED
DW-4000 - HORIZONTAL INSTALLATION
FIELD CUT/NOTCH JAMB
EXTRUSION AT HEAD AND
JAMB (NOT BY KINGSPAN)
SEALANT END DAM
TWO PIECE HEAD
EXTRUSION CAP
3
EXPOSED SEALANT
(NOT BY KINGSPAN)
N
SIO
U
TR
CE
O
TW
PIE
2
TWO PIECE HEAD EXTRUSION BASE W/
FIELD DRILL 3 8
(NOT BY KINGSPAN)
1
TWO PIECE JAMB
EXTRUSION BASE
6
EXPOSED SEALANT
(NOT BY KINGSPAN)
TWO PIECE JAMB EXTRUSION
X
DE
A
HE
4
FIELD CUT/NOTCH JAMB
EXTRUSION
(NOT BY KINGSPAN)
5
ON
TR
EX
L
IL
I
US
S
EXTRUSION AT
FRAMED OPENING
TWO PIECE JAMB
EXTRUSION CAP
TWO PIECE JAMB
EXTRUSION CAP
EXTRUSION INSTALLATION SEQUENCE:
1
TWO PIECE JAMB EXTRUSION BASE
2
TWO PIECE HEAD EXTRUSION BASE
3
TWO PIECE HEAD EXTRUSION CAP
4
TWO PIECE JAMB EXTRUSION CAP
5
SILL EXTRUSION
6
EXTERIOR SEALANTS AS REQUIRED
DW-4000 - HORIZONTAL INSTALLATION
FASTENING CLIP
VJ-1
2" OR 3" FLAT PANEL
VJ-2
2" RIBBED PANEL
3" RIBBED PANEL
VERTICAL JOINT GASKET
GASKET AVAILABLE IN BLACK OR LIGHT GRAY
ACCESSORIES