Transconnect Sales Book2_13
Transcription
Transconnect Sales Book2_13
PSP Products, Inc. Transconnect Overview PSP Products, Inc. has developed a unique generator transfer switch like no other on the market. Our patented technology greatly reduces install time, goes outside at the meter, and can be customized to fit your needs. Some of our features include: I. II Retro fit version fits behind the meter for existing homes and small commercial, up to 48kW loads. Comes in three configurations: • semi automatic – manual start/stop • fully automatic start/stop IV. Monitors generator power and stops power flow from generator if power falls below 105 Volts or exceeds 135 Volts on either leg, and will not transfer an unbalanced load. V. All models automatically transfer back to line power. VI. Powers customer’s entire service distribution panel. VII. Models available with plug for portable generator hook up. VIII.Records power outages and errors. IX. Test switch to exercise the system, reset button, and diagnostic lights. X. Redundant controls and safety features to insure reliable and proper operation. XI. Generator maintenance cycle on auto start versions. XII. Whole house surge protection available on new meter base and modular versions. XIII. Internal electrical interlocks allow only one power source (utility company or generator) to supply power to main service panel. XIV.A built-in .2-3 minute time delay allows voltage monitoring of either power source before the transfer occurs. XV. Built-in surge protection is available on certain units. Transconnect Product Line 200Amp [12”W x 14”H] retro-fit version (meter collar) • • • • • • • • • Quick and easy install For existing homes Typically installed by utility Mounts behind the meter Disconnects utility from house Max generator size is 24kw Max electrical service is 200A Manual & Automatic versions available 30 & 50 Amp plugs available for easy, portable generator hook up • Available in optional saltwater resistant poly-carbonate case • Whole home surge protection available Transconnect Product Line 400 Amp [30”W x 36”H] meter-base version 320Amp meter • Perfect for new construction applications – Installed in place of standard utility meter base • Available with service disconnect breakers • Max electrical service is 400A (feeding (2) 200A Panels) • Max generator size is 36kw • Standard & bypass meter blocks available • Can be part pf a service upgrade/replacement or home remodeling project • Typically installed by contractor • Whole home surge protection available Transconnect Product Line [18”W x 16”H] 200 Amp [12”W x 14”H] 200 Amp [14”W x 30”H] non-meter version • Can be installed by utility or contractor • Can be used anywhere meter access is not available • Installs between meter and circuit panel of 200A service • Can be used to supply backup power to one circuit panel of 320A service • 400A version for (2) 200A panels • Available in 2 versions depending on space available – vertical & 2-piece • All include (1) or (2) 200A service disconnect breaker(s) to meet any local code requirement • Max generator size is 36kw • Max electrical service is 400A • Whole Home Surge Protection can be added Circuit Interrupter The PSP Transconnect Interrupter is a relay board designed to disconnect loads from the main electric panel that would otherwise overload a connected generator. The Interrupter should be used in any fully automatic application where the connected generator does not have the capacity to carry the entire, connected load. Loads such as electric hot water heaters, heat pumps, air conditioning systems, water pumps or any devices that are not important to a homeowner to have in operation during a power outage, can be safely taken off line. This allows the TransConnect to automatically operate a generator that is not large enough to carry the entire home on its own. Installation is simple. The Interrupter is mounted next to the existing electric panel and wires are rerouted to the relay box from their current location in the electric panel. Short jumper wires are then installed between each relay and the breaker in the main electric panel that services that circuit. Some models have room to add additional relays in the field for future upgrades. All units are ARL listed and approved to meet all safety standards. Relays: DPDT 24V DC coil voltage Contacts are rated to 30 or 50 Amp, 240V continuous ratings Note: TransConnect or other control device must have Form C contacts with a 2 Amp at 30 Volts maximum rating to operate relays. Model Number Number of Circuits Pi-034B020 4 – 30 Amp Pi-038K030 8 – 30 Amp Pi-038K040 10 – 30 Amp Pi-031T0P0 1 – 25 Amp PiS060-D24 1 – 60 Amp Description 2 double pole 30 amp relays – no terminal block 4 double pole 30 amp relays – with terminal block 5 double pole 30 amp relays – with terminal block Single pole unit with chase nipple and pigtails 60 Amp relay add on – upgrades Pi-038K030 to a 10 circuit panel with 8 – 30 Amp and 2 – 50 Amp circuit that can be interrupted. Size 8” W x 10” H 11” W x 14” H 16” W x 18” H Note: AC or Heat Pump interrupt only: This can be done by routing the Thermostat wire through the “Interrupt” connections on the TransConnect control board. When the generator is engaged, the circuit is broken and the thermostat will be rendered inoperative so the AC or Heat Pump cannot turn on. This method avoids having to purchase an additional relay panel such as those listed above. Install time depends on the distance between the TransConnect and the thermostat in the home. Transconnect Operations The Transconnect Generator Transfer Switch has built in safety features that prevent generator back feed into the utility power system. The attached diagrams are intended to explain the operational flow of electricity in Normal and Emergency conditions. Normal Operation When utility power is present, the normal flow of electricity is through the meter as usual. As the power leaves the meter, it is diverted through a Latching Relay. The Latching Relay is in a closed position to allow power to flow through from the utility to the panel inside the home. An optional Service Disconnect Breaker is available if required by local codes. Voltage Sensor # 1on the Control Board continually monitors the power on the utility side of the meter. The Control Board will report problems with the Utility voltage but it will not disconnect utility power under this type of condition. If a total blackout occurs, the Voltage Sensor # 1will respond by beginning the auto start sequence of an attached stationary generator or it will wait and watch for a portable generator to be hooked up. Emergency Operation Once a blackout condition is confirmed, the Control Board starts the generator or begins to “watch” for a generator to be connected. Voltage Sensor # 3 is the main control component to determine when generator power is present and has stabilized. The transfer switch will not switch to generator power if it does not see 105V to 135V on each leg measured to neutral. The Control Circuit for the Latching Relay energizes the latch, which locks the relay into an “off” or open position. Sensor # 4 verifies the position of the Latching Relay. The Control Circuit(s) for the Generator Relays are then energized to close these normally open relays. Voltage Sensor # 2 confirms power flow through the relays. Power is now supplied to the house without feed back of power into the utility system. Zero voltage is verified at Voltage Sensor # 1. When power is restored by the utility, Voltage Sensor # 1 waits a predetermined period of time to confirm that the power is truly restored and constant. If for any reason the utility power is not stable (such as 120V on one leg and 95V on the other); the TransConnect unit will not switch back to utility power. The Generator Relays are disengaged when any utility voltage is restored by Voltage Sensor # 1 releasing the Independent Control Relays. No Voltage can be present as confirmed by Voltage Sensor # 2 before the Latching Relay is returned to a closed position. Closing the Latching Relay reconnects utility power to the house. This is verified by Sensor # 4. Stationary generators are automatically shut down. Portable generators are left running at an idle and require manual shutdown. Switch off breakers in the panel box to shed load to reduce usage below the generator’s rating. Move the Portable Generator into position near the service entrance. (Not applicable if using a stationary generator) Plug the generator into the TransConnect Transfer Switch. (Not applicable if using a stationary generator) Start the Generator. (The TransConnect automatically switches to generator and then switches back when utility is restored) Shutdown the Generator after utility power is restored. Return the generator and the panel to normal. Product Information Matrix Meter Collar Units - Mounts behind any 200 Amp standard meter Model Number TC-050M210 TC-050M213 TC-050M215 TC-050A210 TC-100M23W TC-100A23E TC-200M23W TC-200A23W Generator Capacity 50 Amp / 12kW 50 Amp / 12kW 50 Amp / 12kW 50 Amp / 12kW 100 Amp / 12kW 100Amp / 12kW 200 Amp / 48kW 200 Amp / 48kW Manual/ Automatic Manual Manual Manual Automatic Manual Automatic Manual Automatic Wiring Between Collar and Electronics Box Flexible conduit Flexible conduit Rigid conduit Flexible conduit Rigid conduit Rigid conduit Rigid conduit Rigid conduit External Mount Style Meter Base L1430 Plug • • • Physical Dimensions 12” x 14.5” 12” x 14.5” 12” x 14.5” 12” x 14.5” 12” x 14.5” 12” x 14.5” 12” x 14.5” 12” x 14.5” • All units available with polycarbonate enclosure for wall unit housing • All units available with 50Amp 4 wire plug • Cords available for connections between generator & transfer switch • All units available with Whole Home Surge Protection Kits Non-Meter Version - Install between Meter Base and Service Panel Model Number TC-05SM2P0 TC-10SM2P0 TC-20SM2P0 TC-05SA2P0 TC-10SA2P0 TC-20SA2P0 TC-05BM2V3 TC-10BM2V0 TC-20BM2V0 TC-05BA2V0 TC-10BA2V0 TC-20BA2V0 Generator Capacity 50 Amp / 12kW 100 Amp / 24kW 200 Amp / 48kW 50 Amp / 12kW 100 Amp / 24kW 200 Amp / 48kW 50 Amp / 12kW 100 Amp / 24kW 200 Amp / 48kW 50 Amp / 12kW 100 Amp / 24kW 200 Amp / 48kW Manual/ Automatic Manual Manual Manual Automatic Automatic Automatic Manual Manual Manual Automatic Automatic Automatic • All units available in split enclosure version • All units available with Whole Home Surge Protection Service Capacity 200A 400A 400A 400A 400A 400A 200A 200A 200A 200A 200A 200A Breaker Single 200 Dual 200 Dual 200 Dual 200 Dual 200 Dual 200 Single 200 Single 200 Single 200 Single 200 Single 200 Single 200 Horizontal/ Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical L1430 Plug • • • Physical Dimensions 13” x 30” 18” x 30” 13” x 30” 18” x 30” 18” x 30” 18” x 30” 13” x 30” 13” x 30” 13” x 30” 13” x 30” 13” x 30” 13” x 30” Power Flow Diagram normal operation voltage path Utility Power Control Divi Voltage Sensor 1* Divi Control Circuit for LatchingIndependant Control Circuits for Relays Relay Voltage Sensor 4* Set of Control Relays that interact with Voltage Sensor # 1 and Independent Control Circuits Voltage Sensor 3* Latching Meter Base Generator Relay Optional Service Disconnect Breaker **NOTE: House Breaker Panel * Voltage Sensor Generator Relay Generator Circuit Breaker Generator Test Switches and Indicator Lights Power Flow Diagram emergency operation voltage path Utility Power Control Divi Voltage Sensor 1* Divi Control Circuit for LatchingIndependant Control Circuits for Relays Relay Voltage Sensor 4* Set of Control Relays that interact with Voltage Sensor # 1 and Independent Control Circuits Voltage Sensor 3* Latching Meter Base Generator Relay Optional Service Disconnect Breaker **NOTE: House Breaker Panel * Voltage Sensor Generator Relay Generator Circuit Breaker Generator Test Switches and Indicator Lights Limited Warranty PSP Products, Inc. expressly warrants its product to the original purchaser of this product, except as noted and listed below, to be free of defects in material and/or workmanship for a period of two (2) years from date of installation or three (3) years from manufacturing date code. Except for this express warranty, the purchaser accepts products(s) “as is”. Remedies under this warranty are limited to repairing or replacing, at PSP Products’ option, any malfunctioning part or component which shall, within the above stated warranty, be returned to PSP Products, Inc. at the address listed below, freight prepaid. This limited warranty does not cover- normal maintenance such as replacement of fuses etc., transportation and installation charges for the replacement part or component, or any other service calls or labor repairs. This warranty does not apply: • If the unit is damaged by an act of God (lightning, flood, etc.) • If the unit has been subject to alteration, neglect, misuse, or abuse. • If installed in a hostile environment that has caused a premature failure. • If damage occurs during shipment or handling by the freight carrier. It is the receiver’s responsibility to process claims involving freight damage. • If damage is caused by improper voltage or power supply source. • If unit is not installed according to manufacturer’s specifications and installation instruction manual. • If incorrect model or size was installed for the application. • If unit contains modifications to internal wiring, removal or bypass of parts, bypass of safety circuits, modification of parts or circuit boards, or mechanical airflow changes not authorized in writing by the factory. • If the serial identification decal (label) is defaced. The returned part or component must contain a warranty tag or information clearly stating serial number, installation date, and nature of failure. Replacement of a part component under this limited warranty does not extend the warranty term or period. There are no other express warranties. Specification sheets and descriptions of this product are only to identify it, and are not a warranty claim that the unit fits the description. We do not warranty this product suitable for a specific installation or application. It is the owner’s (or installer’s) responsibility for proper application. PSP Products, Inc. is not bound by representatives, installers, warranties, or promises made by others beyond the terms of this express warranty. In no event shall PSP Products, Inc. be responsible for any installation incidental or consequential damages. Any action for branch of this limited warranty must be commenced within one year from the date of the breach. This warranty give you specific legal rights, and you may also have other rights which vary from state to state. For example, some states do not allow the exclusion or limitation of incidental or consequential damages. So the above limitation may not apply to you. www.pspproducts.com PSP Products, Inc. P.O.Box 4108 • Manassas, Va 20108 Tel 800.648.6802 • fax 800.767.6645 www.pspproducts.com • sales@pspproducts.com
Similar documents
TransConnect II TransConnect II
TransConnect II Self contained portable generator transfer switch allows
More information