Fume Hoods - Ant Teknik
Transcription
Fume Hoods - Ant Teknik
Fume Hoods SELECTION GUIDE Fume Hoods Description Filter Work Surface Page BC-01E Clean Benches BC-11E HEPA filter Stainless steel #304 28 Optional 6 different filters Optional 6 different Work Surfaces 32 HEPA filter Acryl 10 mm / 0.39 inch (clear type) 36 Stainless steel #304 36 BC-21E Clean Benches Ductless Fume Hoods PCR Workstations UV Sterilization Cabinets Ductless Fume Hoods DLH-01G DLH-11G PW-01 PCR Workstations PW-11 PW-21 UV Sterilization Cabinets UVC-01 - UVC-11 UVC-21 Accessories & Options Description GENERAL APPLICATIONS Page for Clean Benches 31 for Ductless Fume Hoods 35 for PCR Workstations & UV Sterilization Cabinets 39 General Applications Asbestos Handling BC Models Fume Hoods PW Models • • • Chemical Sampling Chemical Preparation in an electron microscopy or histology laboratory,forensic, and pharmaceutical applications, depending on the solvents used • Cosmetic Production to Photochemical Dental Laboratory Electronics Inspection / Repair • • • • • • • Fingerprinting General Forensics Medical Device Assembly Non-biohazardous [Tissue] Culture Maintenance Non-toxic IV Solution Preparation Numerous Vapor-generating Laboratory Processes • • • • • • PCR • • • • • Powder Extraction QA / QC Testing • • Slide Preparation • Staining with Volatile Sterile Media Preparation • Syringe Filling • • Sterile Media Preparation • • Volatile Radiolabeling / Tagging • • Weighing Toxic Powders • • Tissue Fixation / Staining Preparation • • (HPLC preparation and biochemistry protocols can be performed with improved safety and comfort) Plant Tissue Culture Maintenance DLH Models • Touch up Painting Welding Fumes * Above listed applications are for general and storage purpose use. • TECHNICAL BENEFITS Ductless Fume Hoods Clean Benches PCR Workstations UV Sterilization Cabinets Safety Features Constructional Features Constructional Features - 2 separated over- current fuses for user safety. - Front windows part can be seeing though made by transparent acryl. - Built-in over-current products for user safety. - Toggle switch provided can be selective one of them. (UV, off, and fluorescent) - Lower stand mounted fixable casters easy for moving & fixing. (optional) - Intelligent digital controller. - Automated UV lamp switch off when unintended window opening. - Control panel: consist of fluorescent lamp, Fan Start/Stop, Blower speed controller, alarm, menu and etc. - Pre Filter mounted extends the life of the filters. (PW-Models) - Tempered glass sliding sash window and intercept the UV light for user safety. - Permanent magnehelic differential pressure gauge displays across the HEPA filter to check the air changes. (optional) -U sing a 99.99% efficient supply HEPA filter. Constructional Features - Optimum PWM (pulse width modulation) control performance. - A s a blower of large enough capacity is adapted, sufficient intake flow rate is maintained and noise is reduced. - Dirt-repellent surface external powder coating. - L ight and blower switches are within easy reach of the user. - Great chemical resistance Work Surface (#304) with various organic solvents. - Over-current circuit CP (Circuit Protector) for user safety. - Anemometer: visual for the input air velocity at real time. - Door Stay: fixture to fix it when door open at 2 step. (if it’s dropped without backing up, result in damage, and fixing magnetic enable to open hold it to 1 step-door.) (timer, alarm, blower speed (PW-Models)) - High quality 99.99% efficient supply HEPA filter. - Powerful, uniformly distributed, UV-C. (average 8,000 hours) - Excellent chemical resistance work surface. - Automated UV lamp switch off. F Please visit Fume Hoods Clean Benches .com For further information on Jeio Tech´s Fume Hood products Information is readily available on our website. BC-11E Optional Accessories see page 31 • Stand with Caster • Differential Pressure Gauge ※ Product design subject to change without notice. 28 Fume Hoods Clean Benches Vertical type laminar flow clean bench! ISO 14644-1 Class 4 air. (formerly Class 10 per Federal Standard 209E) Supply HEPA filter, high efficient for particles beginning at size 0.3micron. Nominal downflow velocity of 0.3m/s. (60fpm) Ergonomic 5 degree sloped front for comfort. Filtration Features Control Panel Particle-free ISO 14644-1 Class 4 air • Particle count in the work area conform to ISO Class 4 conditions. (formerly Class 10 per Federal Standard 209E) Supply HEPA filter, 99.99% efficient on particles 0.3 micron. • Polyester fiber Pre Filter that has a minimal pressure loss and 85% arrestance on the A.F.L. test which serves to trap larger particles and increase the life of the main filter. • Neoprene gaskets ensures that the HEPA filter is airtight to the body unit. ※ The HEPA filters life span depending on the test room conditions has a life span about 3 years. Constructional Features Ergonomic Design • A ngled front profile is free of protrusions that will not interfere with visibility or obstruct tall users. • 304 grade stainless steel Work Surface - highly durable and rust free work zone, made for easy cleaning. • Use of tempered glass door to be strong of damage and intercepts the UV light for user safety. • The door smoothly slides up and down and stops at any height useful for protecting the user when used at a proper level or for easy transportation of experimental apparatuses and equipments into the workspace. • Right and left both sides also have wide glasses windows for a clear viewing. • Adjustable blower located by the front blower switch. Service Fixtures (optional) Gas Lighting • Electronically ballasted FL lamp is installed on the top center roof inside the hood that minimizes airflow disturbance and shadows in the work zone, and to relieves eye strain. •T oggle switch provided can be set up to turn On/Off UV, off, and fluorescent functions, so one can make sure that the user is safely protected from careless switching on UV & fluorescent lamps at the same time. Clean Bench Airflow Profile • Room air is taken in from the top blower of the bench through a disposable Pre Filter. • The filtered air is first purified by the secondary HEPA filter to confirm to class standards. • The laminar down-flowing air is supplies from the dual filtering system into the working zone. • The clean bench work zone easily maintains a high sterile condition due to positive pressure preventing outside contaminants. • The purified air flows across the work zone in the cabinet in a vertical, unidirectional stream and leaves the main work chamber across the entire open front of the cabinet and in through the slots. Vacuum Air 29 F Fume Hoods Clean Benches Dimension (Model: BC-11E) Air Flow Diagram 1 12 2 11 3 4 5 8 6 7 9 10 1. Pre Filter 2. Blower 7. Service Fixture 3. HEPA Filter 4. UV Lamp 8. Sliding Front Sash Window 11. Blower Speed Controller 5. Fluorescent Lamps 9. Electrical Outlet socket 6. Tempered Glass Side Panel 10. Stainless Steel Grade 304 Work Surface 12. Differential Pressure Gauge Specifications & Ordering Information Model BC-01E Filters HEPA Filter Pre Filter Noise Level Main Body Work Surface Windows (Front / Side) Intensity (lux) Illumination FL lamp (W) UV lamp (W) Electric Socket Outlets Materials Dimension (W×D×H) BC-21E Typical efficiency of 99.99% at 0.3㎛ US MIL - STD -282 ; Micro glass fiber Media, Particle board, AL separator, Neoprene gaskets Polyester fibers with an efficiency of 85% (A·F·I TEST) ; AL frame, Polyester fiber media Typically < 67dBA at initial blower speed Stainless steel grade 304 & Steel powder coating Stainless steel grade 304 Colorless and transparent UV absorbing 5mm tempered glass >1000 30W×2ea electronically ballasted FL Lamp 30W electronically ballasted UV Lamp 230V socket / 120V socket Internal (mm / inch) 970×540×570 / 38.2×21.3×23.2 1270×540×570 / 50×21.3×23.2 1870×540×570 / 73.6×21.3×23.2 External without Stand (mm / inch) 1040×630×1060 / 40.1×24.8×42.7 1340×630×1060 / 52.8×24.8×42.7 1940×630×1060 / 76.4×24.8×42.7 External with Stand (mm / inch) 1040×630×1780 / 40.1×24.8×70.1 1340×630×1780 / 52.8×24.8×70.1 1940×630×1780 / 76.4×24.8×70.1 110 / 242.5 130 / 302 60Hz / 1.7A 50Hz / 1.82A AAHA4011K AAHA4012K 60Hz / 3.48A AAHA4013U 127 / 280 150 / 330.7 60Hz / 1.7A 50Hz / 1.82A AAHA4021K AAHA4022K 60Hz / 3.48A AAHA4023U 163 / 359.4 190 / 418.9 60Hz / 1.7A 50Hz / 1.82A AAHA4031K AAHA4032K 60Hz / 3.48A AAHA4033U Net Weight (Body) (kg / lbs) Net Weight (Body+Stand) (kg / lbs) Electrical Requirements (230V / 1ph) Cat. No. Electrical Requirements (120V / 1ph) Cat. No. 30 BC-11E Vertical flow 274 to 914 cmh / 119 to 399 cfm 0.3 / 60 ISO 14644-1 Class 4, US Federal Standard 209E Class 10 Air Flow Type Air Volume (Minimum / Maximum) Laminar Airflow Velocity (m / s / fpm) Air Cleanliness within Working Area Fume Hoods Accessories & Options for Clean Bench HEPA Filter (1EA included) -9 9.99% efficient HEPA filter, industry standard size for economical replacement. Service Fixture (optional) -C onveniently hook up source a Gas/ Vacuum/ Air source within the working area. Electric Sockets (optional) Pre Filter (1EA included) - Provided included a conveniently placed power source for small devices or equipment used within the cabinet. Two style of outlets are available; 120V and 230V outlets. - Replaceable Pre Filter, to trap larger particles, extends HEPA filter life. Basic Stand (optional) Stand with Casters (optional) - Economical basic stand without casters made of powder coated steel. - For easy transport with casters made of powder coated steel. -C SA limited (Canadian Standards Association) Differential Pressure Gauge (optional) - Permanent magnhelic pressure differential gauge display across the HEPA filter to check the air changes. Cat. No. AAAB1501 AAAB1502 AAAB1503 AAAB1511 AAAB1512 AAAB1513 AAAB1521 AAAB1522 AAAB1523 AAAB1531 Description HEPA Filter Pre Filter Basic Stand Stand with Casters UV Lamp (optional) - For secondary method of decontamination while the bench is not in use. Suitable for BC-01E BC-11E BC-21E BC-01E BC-11E BC-21E BC-01E BC-11E BC-21E BC-01E Cat. No. AAAB1532 AAAB1533 AAAB1541 AAAB1542 AAAB1543 AAAB1544 AAAB1545 AAAB1546 AAAB1551 AAAB1561 AAAB1571 Description Stand with Casters UV Lamp Electrical Socket Gas Cock Differential Pressure Gauge Suitable for BC-11E BC-21E BC-01E (230V) BC-01E (120V) BC-11E (230V) BC-11E (120V) BC-21E (230V) BC-21E (120V) BC-01/11/21E BC-01/11/21E BC-01/11/21E ※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specific needs. Please contact Jeio Tech for details. 31 F Please visit Fume Hoods Ductless Fume Hoods .com For further information on Jeio Tech´s Fume Hood products Information is readily available on our website. DLH-01G Optional Accessories see page 35 32 • Stand with Caster • Different Types of Chemical Filters • 6 Different Types of Work Surfaces Fume Hoods Ductless Fume Hoods Ductless Fume Hoods are manufactured and gone through a complete safety tests of rigorously international standards. Constructional Features • Internal airflow speed in the workspace can be identified with attached anemometer. Airflow speed can be controlled by identifying varying wind speeds in accordance with the surroun-ding environments and filter conditions. • Connection with a separate exhaust system is not required, since the hood uses reticulating air flow by discharging the filtered air into the laboratory. • Other types of filter cartridges can be easily replaced by opening the upper cover located in the front. • Front sash can be fully opened or fixed for easy transportation of experimental apparatuses and equipments into the workspace. • A utility hole is manufactured in the fume hood, for use of apparatuses inside the hood allows for easy connection of power source or other cable outport sources outside the hood. • A blower of large enough capacity is adopted into the equipment so sufficient intake air flow rate is maintained to reduce noise. • A fluorescent light is provided outside the workspace so that the air flow is not hindered, prevents contamination of reagents and the illumination intensity is maintained. • Various filters and Work Surfaces are available to fit your experimental needs. Digital Controller Anemometer (refer to accessory section) Reliable Test : E fficiency, capacity of activated carbon filters tested according to BS 7989:2001 : S tructure, electrical outlet, lighting, sound level tested according to BS 7258-1:1994 : L ocal smoke, large volume visualization, face velocity, tracer gas tested according to ANSI / ASHRAE 110-1995, NF EN 14175-1 Utility Hole Front Cover Selection for Chemical Filter Code Filter Name Application GF AC HF FF AM Activated Carbon Filter Acid Filter Halogen Compound Filter Formaldehyde Filter Ammonia / Amine Filter All common laboratory chemicals, especially VOC, Organic, Benzene, Toluene, etc An acidic solvent; Acetic acid, etc Halogen compounds like Chlorine, Flourine, Iodine, Bromine, Astatine, etc Formadehyde applications Ammonia / Amines by chemisorptions HEPA HEPA Filter The filtration efficiency of 99.99% at 0.3 microns for trapping biohazardous aerosols and other visible and non visible particles 33 F Fume Hoods Ductless Fume Hoods Dimension (Model: DLH-01G) Air Flow Diagram 1 2 3 4 5 6 1250 7 834 8 9 10 11 12 1. Exhaust Hole 2. Pre Filter 6. Chemical Filter 9. Front Door 3. Front Cover 7. F.L. Lamp (inner) 10. Side Viewing Panel 4. Blower 5. Control Panel 8. Anemometer 11. Door Opening Fixed Magnet 12. Utility Hole Specifications & Ordering Information Model Fume HoodType Permissible Environmental Condition Controller Face Velocity Air Flow Meter Main Filter Pre Filter Main Body Work Surface Window (Front / Side) Fluorescent Light Intensity Sound Emission Internal (mm / inch) External without Stand (mm / inch) Dimension External with Stand (mm / inch) (W×D×H) Net Weight (Body) (kg / lbs) Net Weight (Body+Stand) (kg / lbs) Electrical Requirements (230V) Cat. No. Electrical Requirements (230V) Cat. No. Electrical Requirements (120V) Cat. No. Electrical Requirements (100V) Cat. No. Materials 34 DLH-01G DLH-11G Ductless Temperature 5℃ to 40℃ Maximum relative humidity 80% Altitude up to 2,000m Microprocessor control Initial set point: 0.4m/s, 80fpm Swing vane type Chemical Filter (optional 6 different filters) Washable high efficiency nylon filter 2.0mm steel (epoxy powder-coated) Optional 6 different work surfaces Acryl 8mm / Acryl 6mm > 600lux 55dB at normal operation 880×640×800 / 34.6×25.2×31.5 1180×640×800 / 46.5×25.2×31.5 900×660×1250 / 35.4×26×49.2 1200×660×1250 / 47.2×26×49.2 900×660×1985 / 35.4×26×78.1 1200×660×1985 / 47.2×26×78.1 100 / 220.5 118 / 260.1 120 / 264.6 140 / 308.6 60Hz / 0.7A AAHB2001K AAHB2011K 50Hz / 0.6A AAHB2002K AAHB2012K 60Hz / 1.3A AAHB2003U AAHB2013U 50Hz / 1.5A AAHB2004U AAHB2014U Fume Hoods Accessories & Options for Ductless Fume Hoods Gas Detector and Tubes Filters Work Surface Stand with Caster Cat. No. AAAB2521 AAAB2522 EDA9191 EDA9192 EDA9199 EDA9200 EDA9201 EDA9202 EDA9203 EDA9204 EDA9205 EDA9206 EDA9193 EDA9194 EDA9196 EDA9198 Description Stand with Casters GF Activated Carbon Filter AC Acid Filter HF Halogen Compounds Filter FF Formaldehyde Filter AM Ammonia / Amines Filter HEPA Filter Pre filter Suitable for Cat. No. DLH-01G AAAB2501 AAAB2502 AAAB2503 AAAB2504 AAAB2505 AAAB2506 AAAB2507 AAAB2508 AAAB2509 AAAB2510 AAAB2511 AAAB2512 AAAB2531 EAA1550 EDA9207 EAA1552 EAA1553 EAA1554 EAA1555 DLH-11G DLH-01G DLH-11G DLH-01G DLH-11G DLH-01G DLH-11G DLH-01G DLH-11G DLH-01G DLH-11G DLH-01G DLH-11G DLH-01G DLH-11G Description Work Surface (SUS #304) Work Surface (SUS #316L) Work Surface (Ceramite) Work Surface (Polypropylene) Work Surface (Bakelite) Work Surface (PVC) Gas Detector (KITAGAWA AP-20) Gas Detecting Tube (Benzene, GASTEC-121SP (0.5-10ppm)) Gas Detecting tube (Toluene, GASTEC-122L (1-100ppm)) Gas Detecting tube (Acetic acid, GASTEC-81L (0.125-25ppm)) Gas Detecting tube (Chloroform, GASTEC-137 (4-400ppm)) Gas Detecting tube (Formaldehyde, GASTEC-91LL (0.05-1ppm)) Gas Detecting tube (Ammonia, GASTEC-3L (0.5-60ppm)) Suitable for DLH-01G DLH-11G DLH-01G DLH-11G DLH-01G DLH-11G DLH-01G DLH-11G DLH-01G DLH-11G DLH-01G DLH-11G DLH 01G /11G ※ Above specifications can be changed without prior notice. 35 F Please visit Fume Hoods PCR Workstations & UV Sterilization Cabinets .com For further information on Jeio Tech´s Fume Hood products Information is readily available on our website. PCR Workstations Included Accessories see page 39 • HEPA Filter • Pre Filter • UV Lamp • Fluorescent Lamp UV Sterilization Cabinets Included Accessories see page 39 36 • UV Lamp • Fluorescent Lamp Fume Hoods PCR Workstations & UV Sterilization Cabinets Using a HEPA filter provides an effective particulate-free working space from ambient environment conditions. – PW Models High quality UV lamp with a timer control feature is great for sterilizing the instruments before carrying out sensitive or PCR experiments. - UVC Models Constructional Features PCR Workstations Effective sterilization 254nm ultraviolet lamp and Fluorescent lamp. • Adjustable UV-timer for precise control of decontamination. - Th e variable digital timer for UV exposure with detail settings by second. (delay OFF: Max. 30min) - Long life (up to 8,000 hour) UV lamp. • Anti-glare fluorescent lamp is installed on the center ceiling of the work space area, minimizing shadows and relieves eye strain. User-Friendly Control System • Microprocessor-based control system. • B right and vivid LCD (PW Models) or VFD (UVC Models) display with responsive touch buttons. • Easily indicating the total use time and operating time on the screen. A reliable interlock safety system • An audible alarm for product and sample protection against UV over exposure. • For safety UV-opaque and resistant 99.99%, thick acryl front, back and sides. • Automatic UV lamp safety shut OFF, in case the door is opened, which prevents accidental UV exposure. • 304 grade stainless steel Work Surface - Highly durable and rust free work zone, made for easy cleaning. (UVC Models) • Self-protection against over-current. Digital Controller Air Flow Additional Features Filtration features (PW-Models) • Particle-free ISO 14644-1 HEPA filter (Class 4 conditions) - Using a 99.99%, efficiency HEPA filter that filters particle sizes of 0.3 micron and greater, traps biohazardous aerosols, and provides a particulate-free work environments that minimizes cross contamination. • Neoprene gaskets ensures that the HEPA filter is airtight to the body unit. - The HEPA filters life span depending on the test room conditions has a life span of 3 years. • Replacing of the HEPA filter can easily be replaced by opening the upper cover, located in the front. • Polyester fiber Pre Filter that has minimal pressure loss and 85% arrestance on the A.F.L. test which serves to trap larger particles and increases the life of the main filter. • Adjustable digital blower speed switch located in the front with use of large capacity blower is adopted into the equipment. UV Sterilization cabinet Digital Controller 37 F Fume Hoods PCR Workstations & UV Sterilization cabinets Specifications & Ordering Information PCR Workstations Model PW-01 PW-11 Max. Air Volume (cmh / cfm) 557 / 327 697 / 408 Min. Air Volume (cmh / cfm) 167 / 97 209 / 121 929 / 546 279 / 162 0.3 / 60 Laminar Airflow Velocity (m / s / fpm) ISO 14644-1Class 4 Air Cleanliness Filter Typical efficiency of 99.99% at 0.3 ㎛ US MIL -STD -282 ; Micro glass fiber Media, Particle board, AL separator, Neoprene gaskets HEPA Filter Polyester fibers with an efficiency of 85% (A·F·I TEST); AL frame, Polyester fiber media Pre Filter Typically < 60 dBA at initial blower speed Noise level (dBA) Material Acryl 8mm / 10mm (clear type) Window (Front, Side / Back) Illumination Capacity (W×D×H) Acryl 10mm (clear type) Work Surface Intensity Dimension PW-21 Vertical Air Flow Type >1000 FL Lamp (lux) 165 185 330 15W×1EA 20W×1EA 30W×1EA UV Density (㎼/cm2) FL Lamp 15W×1EA 20W×1EA 30W×1EA Interior (mm / inch) 700×585×602 / 27.5×23×23.7 880×585×602 / 34.6×23×23.7 1180×585×602 / 46.5×23×23.7 Exterior (mm / inch) 720×605×964 / 28×24×38 900×605×964 / 35.4×24×38 1200×605×964 / 47.2×24×38 UV Lamp 56.2 / 123.9 Net Weight (Body) (kg / lbs) Electrical Requirements (230V) Cat. No. 64.2 / 141.5 77.8 / 171.5 60Hz, 1.3A 50Hz, 1.3A 60Hz, 1.4A 50Hz, 1.4A 60Hz, 1.5A 50Hz, 1.5A AAHB3001K AAHB3002K AAHB3011K AAHB3012K AAHB3021K AAHB3022K Electrical Requirements (120V) Cat. No. 60Hz, 2.2A 60Hz, 2.7A 60Hz, 2.9A AAHB3003U AAHB3013U AAHB3023U Specifications & Ordering Information UV Sterilization cabinets Model Intensity Illumination Capacity Material Dimension (W×D×H) UVC-01 UVC-21 >800 >900 >1000 UV Density (㎼ / ㎠) 150 385 450 Fl Lamp 8W×1ea 15W×1ea 20W×1ea UV Lamp 8W×1ea 15W×1ea 20W×1ea Stainless steel grade 304 Work Surface Acryl 5 mm (clear type) Window (Front, Back / Side) Interior (mm / inch) 433×500×468 / 17.0×19.7×18.4 583×500×468 / 23×19.7×18.4 880×500×468 / 34.6×19.7×18.4 Exterior (mm / inch) 450×509×610 / 17.7×20×24 600×509×610 / 23.6×20×24 900×509×610 / 35.4×20×24 Net Weight (Body) (kg / lbs) 15 / 33.1 17.5 / 38.6 20 / 44.1 Electrical Requirements (230V) 60Hz, 0.1A 50Hz, 0.1A 60Hz, 0.2A 50Hz, 0.2A 60Hz, 0.3A 50Hz, 0.3A Cat. No. AAHB4001K AAHB4002K AAHB4011K AAHB4012K AAHB4021K AAHB4022K Electrical Requirements (120V) Cat. No. ※ Above specifications can be changed without prior notice. 38 UVC-11 Fl Lamp (Lux) 60Hz, 0.2A 60Hz, 0.4A 60Hz, 0.6A AAHB4003U AAHB4013U AAHB4023U Fume Hoods Accessories & Options for PCR Workstaions & UV Sterilization Cabinets General UV Dose and Time Required Average UV Dose Required Pathogen (㎼ . s/㎠) PW-01 165 Average UV Time Required (㎼/ ㎠ /sec.) UVC-01 PW-11 UVC-11 PW-21 150 185 385 330 UVC-21 450 S. enteritidis 4,000 25 27 22 10 13 B. megatherium sp. (spores) 2,730 17 18 15 7 9 9 6 B. subtilis 7,100 43 47 39 18 22 16 Eberthella typhosa 2,140 13 14 12 6 7 5 Escherichia coli (E. coli) 3,000 19 20 17 8 10 7 Micrococcus candidus 6,050 37 40 33 16 19 13 Proteus vulgaris 2,640 16 18 15 7 8 6 Pseudomonas aeruginosa 5,500 34 37 30 14 17 12 Pseudomonas aeruginosa 3,500 22 23 19 9 11 8 S. typhimurium 8,000 49 53 44 21 25 18 Shigella paradysenteriae 1,680 101 11 10 4 6 4 Spirillum rubrum 4,400 27 29 24 11 14 10 Staphylococcus albus 1,840 12 12 10 5 6 4 * Permissible environmental conditions: temperature (20 to 25℃) and relative humidity (up to 60%). * Above listed applications are for general purpose use. for PCR Workstations Cat. No. Description HEPA Filter PW-11 PW-21 EDA9221 PW-01 CHE4436 CHE4410 Lighting Lamp HEPA Filter PW-11 PW-21 CHE4409 PW-01 CHE4431 CHE4427 Suitable for PW-01 EDA9219 EDA9220 Filters (PW Models) UV Lamp PW-11 PW-21 CHE4423 Pre Filter for UV Sterilization Cabinets Cat. No. Description Lighting Lamp UVC-01 CHE4434 CHE4427 UVC-11 UVC-21 CHE4410 CHE4431 Suitable for UVC-01 CHE4435 CHE4436 Lamps (PW and UVC Models) UV Lamp UVC-11 UV Lamp UVC-21 Fluorescent Lamp 39