Fume Hoods
SELECTION
GUIDE
Fume Hoods
Description
Filter
Work Surface
Page
BC-01E
Clean Benches
BC-11E
HEPA filter
Stainless steel #304
28
Optional 6
different filters
Optional 6 different
Work Surfaces
32
HEPA filter
Acryl 10 mm / 0.39 inch
(clear type)
36
Stainless steel #304
36
BC-21E
Clean Benches
Ductless Fume Hoods
PCR Workstations
UV Sterilization Cabinets
Ductless Fume
Hoods
DLH-01G
DLH-11G
PW-01
PCR Workstations
PW-11
PW-21
UV Sterilization
Cabinets
UVC-01
-
UVC-11
UVC-21
Accessories & Options
Description
GENERAL
APPLICATIONS
Page
for Clean Benches
31
for Ductless Fume Hoods
35
for PCR Workstations & UV Sterilization Cabinets
39
General Applications
Asbestos Handling
BC Models
Fume Hoods
PW Models
•
•
•
Chemical Sampling
Chemical Preparation
in an electron microscopy or histology
laboratory,forensic, and pharmaceutical
applications, depending on the solvents used
•
Cosmetic Production to
Photochemical
Dental Laboratory
Electronics Inspection / Repair
•
•
•
•
•
•
•
Fingerprinting
General Forensics
Medical Device Assembly
Non-biohazardous [Tissue] Culture
Maintenance
Non-toxic IV Solution Preparation
Numerous Vapor-generating
Laboratory Processes
•
•
•
•
•
•
PCR
•
•
•
•
•
Powder Extraction
QA / QC Testing
•
•
Slide Preparation
•
Staining with Volatile
Sterile Media Preparation
•
Syringe Filling
•
•
Sterile Media Preparation
•
•
Volatile Radiolabeling / Tagging
•
•
Weighing Toxic Powders
•
•
Tissue Fixation / Staining Preparation
•
•
(HPLC preparation and biochemistry protocols
can be performed with improved safety and
comfort)
Plant Tissue Culture Maintenance
DLH Models
•
Touch up Painting
Welding Fumes
* Above listed applications are for general and storage purpose use.
•
TECHNICAL BENEFITS
Ductless Fume Hoods
Clean Benches
PCR Workstations
UV Sterilization Cabinets
Safety Features
Constructional Features
Constructional Features
- 2 separated over- current fuses for user
safety.
- Front windows part can be seeing
though made by transparent acryl.
- Built-in over-current products for user
safety.
- Toggle switch provided can be selective
one of them. (UV, off, and fluorescent)
- Lower stand mounted fixable casters
easy for moving & fixing. (optional)
- Intelligent digital controller.
- Automated UV lamp switch off when
unintended window opening.
- Control panel: consist of fluorescent
lamp, Fan Start/Stop, Blower speed
controller, alarm, menu and etc.
- Pre Filter mounted extends the life of
the filters. (PW-Models)
- Tempered glass sliding sash window and
intercept the UV light for user safety.
- Permanent magnehelic differential pressure gauge displays across the HEPA
filter to check the air changes. (optional)
-U
sing a 99.99% efficient supply HEPA filter.
Constructional Features
- Optimum PWM (pulse width modulation)
control performance.
- A s a blower of large enough capacity
is adapted, sufficient intake flow rate is
maintained and noise is reduced.
- Dirt-repellent surface external powder
coating.
- L ight and blower switches are within
easy reach of the user.
- Great chemical resistance Work Surface
(#304) with various organic solvents.
- Over-current circuit CP (Circuit Protector)
for user safety.
- Anemometer: visual for the input air
velocity at real time.
- Door Stay: fixture to fix it when door open
at 2 step. (if it’s dropped without backing up,
result in damage, and fixing magnetic enable to
open hold it to 1 step-door.)
(timer, alarm, blower speed (PW-Models))
- High quality 99.99% efficient supply
HEPA filter.
- Powerful, uniformly distributed, UV-C.
(average 8,000 hours)
- Excellent chemical resistance work
surface.
- Automated UV lamp switch off.
F
Please visit
Fume Hoods
Clean Benches
.com
For further information on Jeio Tech´s Fume Hood products
Information is readily available on our website.
BC-11E
Optional Accessories
see page 31
• Stand with Caster
• Differential Pressure Gauge
※ Product design subject to change without notice.
28
Fume Hoods
Clean Benches
Vertical type laminar flow clean bench!
ISO 14644-1 Class 4 air. (formerly Class 10 per Federal Standard 209E)
Supply HEPA filter, high efficient for particles beginning at size 0.3micron.
Nominal downflow velocity of 0.3m/s. (60fpm)
Ergonomic 5 degree sloped front for comfort.
Filtration Features
Control Panel
Particle-free ISO 14644-1 Class 4 air
• Particle count in the work area conform to ISO Class 4 conditions. (formerly Class 10 per
Federal Standard 209E) Supply HEPA filter, 99.99% efficient on particles 0.3 micron.
• Polyester fiber Pre Filter that has a minimal pressure loss and 85% arrestance on the
A.F.L. test which serves to trap larger particles and increase the life of the main filter.
• Neoprene gaskets ensures that the HEPA filter is airtight to the body unit.
※ The HEPA filters life span depending on the test room conditions has a life span about 3 years.
Constructional Features
Ergonomic Design
• A ngled front profile is free of protrusions that will not interfere with visibility or
obstruct tall users.
• 304 grade stainless steel Work Surface - highly durable and rust free work zone, made
for easy cleaning.
• Use of tempered glass door to be strong of damage and intercepts the UV light for
user safety.
• The door smoothly slides up and down and stops at any height useful for protecting
the user when used at a proper level or for easy transportation of experimental
apparatuses and equipments into the workspace.
• Right and left both sides also have wide glasses windows for a clear viewing.
• Adjustable blower located by the front blower switch.
Service Fixtures (optional)
Gas
Lighting
• Electronically ballasted FL lamp is installed on the top center roof inside the hood
that minimizes airflow disturbance and shadows in the work zone, and to relieves
eye strain.
•T
oggle switch provided can be set up to turn On/Off UV, off, and fluorescent functions,
so one can make sure that the user is safely protected from careless switching on UV
& fluorescent lamps at the same time.
Clean Bench Airflow Profile
• Room air is taken in from the top blower of the bench through a disposable Pre Filter.
• The filtered air is first purified by the secondary HEPA filter to confirm to class standards.
• The laminar down-flowing air is supplies from the dual filtering system into the
working zone.
• The clean bench work zone easily maintains a high sterile condition due to positive
pressure preventing outside contaminants.
• The purified air flows across the work zone in the cabinet in a vertical, unidirectional
stream and leaves the main work chamber across the entire open front of the cabinet
and in through the slots.
Vacuum
Air
29
F
Fume Hoods
Clean Benches
Dimension (Model: BC-11E)
Air Flow Diagram
1
12
2
11
3
4
5
8
6
7
9
10
1. Pre Filter
2. Blower
7. Service Fixture
3. HEPA Filter
4. UV Lamp
8. Sliding Front Sash Window
11. Blower Speed Controller
5. Fluorescent Lamps
9. Electrical Outlet socket
6. Tempered Glass Side Panel
10. Stainless Steel Grade 304 Work Surface
12. Differential Pressure Gauge
Specifications & Ordering Information
Model
BC-01E
Filters
HEPA Filter
Pre Filter
Noise Level
Main Body
Work Surface
Windows (Front / Side)
Intensity (lux)
Illumination FL lamp (W)
UV lamp (W)
Electric Socket Outlets
Materials
Dimension
(W×D×H)
BC-21E
Typical efficiency of 99.99% at 0.3㎛ US MIL - STD -282
; Micro glass fiber Media, Particle board, AL separator, Neoprene gaskets
Polyester fibers with an efficiency of 85% (A·F·I TEST) ; AL frame, Polyester fiber media
Typically < 67dBA at initial blower speed
Stainless steel grade 304 & Steel powder coating
Stainless steel grade 304
Colorless and transparent UV absorbing 5mm tempered glass
>1000
30W×2ea electronically ballasted FL Lamp
30W electronically ballasted UV Lamp
230V socket / 120V socket
Internal (mm / inch)
970×540×570 /
38.2×21.3×23.2
1270×540×570 /
50×21.3×23.2
1870×540×570 /
73.6×21.3×23.2
External without Stand (mm / inch)
1040×630×1060 /
40.1×24.8×42.7
1340×630×1060 /
52.8×24.8×42.7
1940×630×1060 /
76.4×24.8×42.7
External with Stand (mm / inch)
1040×630×1780 /
40.1×24.8×70.1
1340×630×1780 /
52.8×24.8×70.1
1940×630×1780 /
76.4×24.8×70.1
110 / 242.5
130 / 302
60Hz / 1.7A
50Hz / 1.82A
AAHA4011K
AAHA4012K
60Hz / 3.48A
AAHA4013U
127 / 280
150 / 330.7
60Hz / 1.7A
50Hz / 1.82A
AAHA4021K
AAHA4022K
60Hz / 3.48A
AAHA4023U
163 / 359.4
190 / 418.9
60Hz / 1.7A
50Hz / 1.82A
AAHA4031K
AAHA4032K
60Hz / 3.48A
AAHA4033U
Net Weight (Body) (kg / lbs)
Net Weight (Body+Stand) (kg / lbs)
Electrical Requirements (230V / 1ph)
Cat. No.
Electrical Requirements (120V / 1ph)
Cat. No.
30
BC-11E
Vertical flow
274 to 914 cmh / 119 to 399 cfm
0.3 / 60
ISO 14644-1 Class 4, US Federal Standard 209E Class 10
Air Flow Type
Air Volume (Minimum / Maximum)
Laminar Airflow Velocity (m / s / fpm)
Air Cleanliness within Working Area
Fume Hoods
Accessories & Options
for Clean Bench
HEPA Filter (1EA included)
-9
9.99% efficient HEPA filter, industry
standard size for economical replacement.
Service Fixture (optional)
-C
onveniently hook up source a Gas/ Vacuum/
Air source within the working area.
Electric Sockets (optional)
Pre Filter (1EA included)
- Provided included a conveniently placed
power source for small devices or equipment
used within the cabinet. Two style of outlets
are available; 120V and 230V outlets.
- Replaceable Pre Filter, to trap larger particles,
extends HEPA filter life.
Basic Stand (optional)
Stand with Casters (optional)
- Economical basic stand without casters
made of powder coated steel.
- For easy transport with casters made of
powder coated steel.
-C
SA limited
(Canadian Standards Association)
Differential Pressure Gauge (optional)
- Permanent magnhelic pressure differential
gauge display across the HEPA filter to check
the air changes.
Cat. No.
AAAB1501
AAAB1502
AAAB1503
AAAB1511
AAAB1512
AAAB1513
AAAB1521
AAAB1522
AAAB1523
AAAB1531
Description
HEPA Filter
Pre Filter
Basic Stand
Stand with Casters
UV Lamp (optional)
- For secondary method of decontamination
while the bench is not in use.
Suitable for
BC-01E
BC-11E
BC-21E
BC-01E
BC-11E
BC-21E
BC-01E
BC-11E
BC-21E
BC-01E
Cat. No.
AAAB1532
AAAB1533
AAAB1541
AAAB1542
AAAB1543
AAAB1544
AAAB1545
AAAB1546
AAAB1551
AAAB1561
AAAB1571
Description
Stand with Casters
UV Lamp
Electrical Socket
Gas Cock
Differential Pressure Gauge
Suitable for
BC-11E
BC-21E
BC-01E (230V)
BC-01E (120V)
BC-11E (230V)
BC-11E (120V)
BC-21E (230V)
BC-21E (120V)
BC-01/11/21E
BC-01/11/21E
BC-01/11/21E
※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specific needs.
Please contact Jeio Tech for details.
31
F
Please visit
Fume Hoods
Ductless Fume Hoods
.com
For further information on Jeio Tech´s Fume Hood products
Information is readily available on our website.
DLH-01G
Optional Accessories
see page 35
32
• Stand with Caster
• Different Types of Chemical Filters
• 6 Different Types of Work Surfaces
Fume Hoods
Ductless Fume Hoods
Ductless Fume Hoods are manufactured and gone through a complete
safety tests of rigorously international standards.
Constructional Features
• Internal airflow speed in the workspace can be identified with attached anemometer.
Airflow speed can be controlled by identifying varying wind speeds in accordance
with the surroun-ding environments and filter conditions.
• Connection with a separate exhaust system is not required, since the hood uses reticulating air flow by discharging the filtered air into the laboratory.
• Other types of filter cartridges can be easily replaced by opening the upper cover
located in the front.
• Front sash can be fully opened or fixed for easy transportation of experimental apparatuses and equipments into the workspace.
• A utility hole is manufactured in the fume hood, for use of apparatuses inside the hood
allows for easy connection of power source or other cable outport sources outside
the hood.
• A blower of large enough capacity is adopted into the equipment so sufficient intake
air flow rate is maintained to reduce noise.
• A fluorescent light is provided outside the workspace so that the air flow is not hindered, prevents contamination of reagents and the illumination intensity is maintained.
• Various filters and Work Surfaces are available to fit your experimental needs.
Digital Controller
Anemometer
(refer to accessory section)
Reliable Test
: E fficiency, capacity of activated carbon filters tested according to BS 7989:2001
: S tructure, electrical outlet, lighting, sound level tested according to BS 7258-1:1994
: L ocal smoke, large volume visualization, face velocity, tracer gas tested according to
ANSI / ASHRAE 110-1995, NF EN 14175-1
Utility Hole
Front Cover
Selection for Chemical Filter
Code
Filter Name
Application
GF
AC
HF
FF
AM
Activated Carbon Filter
Acid Filter
Halogen Compound Filter
Formaldehyde Filter
Ammonia / Amine Filter
All common laboratory chemicals, especially VOC, Organic, Benzene, Toluene, etc
An acidic solvent; Acetic acid, etc
Halogen compounds like Chlorine, Flourine, Iodine, Bromine, Astatine, etc
Formadehyde applications
Ammonia / Amines by chemisorptions
HEPA
HEPA Filter
The filtration efficiency of 99.99% at 0.3 microns for trapping biohazardous aerosols and other
visible and non visible particles
33
F
Fume Hoods
Ductless Fume Hoods
Dimension (Model: DLH-01G)
Air Flow Diagram
1
2
3
4
5
6
1250
7
834
8
9
10
11
12
1. Exhaust Hole
2. Pre Filter
6. Chemical Filter
9. Front Door
3. Front Cover
7. F.L. Lamp (inner)
10. Side Viewing Panel
4. Blower
5. Control Panel
8. Anemometer
11. Door Opening Fixed Magnet
12. Utility Hole
Specifications & Ordering Information
Model
Fume HoodType
Permissible
Environmental Condition
Controller
Face Velocity
Air Flow Meter
Main Filter
Pre Filter
Main Body
Work Surface
Window (Front / Side)
Fluorescent Light Intensity
Sound Emission
Internal (mm / inch)
External without Stand (mm / inch)
Dimension
External with Stand (mm / inch)
(W×D×H)
Net Weight (Body) (kg / lbs)
Net Weight (Body+Stand) (kg / lbs)
Electrical Requirements (230V)
Cat. No.
Electrical Requirements (230V)
Cat. No.
Electrical Requirements (120V)
Cat. No.
Electrical Requirements (100V)
Cat. No.
Materials
34
DLH-01G
DLH-11G
Ductless
Temperature 5℃ to 40℃
Maximum relative humidity 80%
Altitude up to 2,000m
Microprocessor control
Initial set point: 0.4m/s, 80fpm
Swing vane type
Chemical Filter (optional 6 different filters)
Washable high efficiency nylon filter
2.0mm steel (epoxy powder-coated)
Optional 6 different work surfaces
Acryl 8mm / Acryl 6mm
> 600lux
55dB at normal operation
880×640×800 / 34.6×25.2×31.5
1180×640×800 / 46.5×25.2×31.5
900×660×1250 / 35.4×26×49.2
1200×660×1250 / 47.2×26×49.2
900×660×1985 / 35.4×26×78.1
1200×660×1985 / 47.2×26×78.1
100 / 220.5
118 / 260.1
120 / 264.6
140 / 308.6
60Hz / 0.7A
AAHB2001K
AAHB2011K
50Hz / 0.6A
AAHB2002K
AAHB2012K
60Hz / 1.3A
AAHB2003U
AAHB2013U
50Hz / 1.5A
AAHB2004U
AAHB2014U
Fume Hoods
Accessories & Options
for Ductless Fume Hoods
Gas Detector and Tubes
Filters
Work Surface
Stand with Caster
Cat. No.
AAAB2521
AAAB2522
EDA9191
EDA9192
EDA9199
EDA9200
EDA9201
EDA9202
EDA9203
EDA9204
EDA9205
EDA9206
EDA9193
EDA9194
EDA9196
EDA9198
Description
Stand with Casters
GF Activated Carbon Filter
AC Acid Filter
HF Halogen Compounds Filter
FF Formaldehyde Filter
AM Ammonia / Amines Filter
HEPA Filter
Pre filter
Suitable for
Cat. No.
DLH-01G
AAAB2501
AAAB2502
AAAB2503
AAAB2504
AAAB2505
AAAB2506
AAAB2507
AAAB2508
AAAB2509
AAAB2510
AAAB2511
AAAB2512
AAAB2531
EAA1550
EDA9207
EAA1552
EAA1553
EAA1554
EAA1555
DLH-11G
DLH-01G
DLH-11G
DLH-01G
DLH-11G
DLH-01G
DLH-11G
DLH-01G
DLH-11G
DLH-01G
DLH-11G
DLH-01G
DLH-11G
DLH-01G
DLH-11G
Description
Work Surface (SUS #304)
Work Surface (SUS #316L)
Work Surface (Ceramite)
Work Surface (Polypropylene)
Work Surface (Bakelite)
Work Surface (PVC)
Gas Detector (KITAGAWA AP-20)
Gas Detecting Tube (Benzene, GASTEC-121SP (0.5-10ppm))
Gas Detecting tube (Toluene, GASTEC-122L (1-100ppm))
Gas Detecting tube (Acetic acid, GASTEC-81L (0.125-25ppm))
Gas Detecting tube (Chloroform, GASTEC-137 (4-400ppm))
Gas Detecting tube (Formaldehyde, GASTEC-91LL (0.05-1ppm))
Gas Detecting tube (Ammonia, GASTEC-3L (0.5-60ppm))
Suitable for
DLH-01G
DLH-11G
DLH-01G
DLH-11G
DLH-01G
DLH-11G
DLH-01G
DLH-11G
DLH-01G
DLH-11G
DLH-01G
DLH-11G
DLH 01G /11G
※ Above specifications can be changed without prior notice.
35
F
Please visit
Fume Hoods
PCR Workstations & UV Sterilization Cabinets
.com
For further information on Jeio Tech´s Fume Hood products
Information is readily available on our website.
PCR Workstations
Included Accessories
see page 39
• HEPA Filter
• Pre Filter
• UV Lamp
• Fluorescent Lamp
UV Sterilization Cabinets
Included Accessories
see page 39
36
• UV Lamp
• Fluorescent Lamp
Fume Hoods
PCR Workstations & UV Sterilization Cabinets
Using a HEPA filter provides an effective particulate-free working space from
ambient environment conditions. – PW Models
High quality UV lamp with a timer control feature is great for sterilizing the
instruments before carrying out sensitive or PCR experiments. - UVC Models
Constructional Features
PCR Workstations
Effective sterilization 254nm ultraviolet lamp and Fluorescent lamp.
• Adjustable UV-timer for precise control of decontamination.
- Th
e variable digital timer for UV exposure with detail settings by second.
(delay OFF: Max. 30min)
- Long life (up to 8,000 hour) UV lamp.
• Anti-glare fluorescent lamp is installed on the center ceiling of the work space area,
minimizing shadows and relieves eye strain.
User-Friendly Control System
• Microprocessor-based control system.
• B right and vivid LCD (PW Models) or VFD (UVC Models) display with responsive touch buttons.
• Easily indicating the total use time and operating time on the screen.
A reliable interlock safety system
• An audible alarm for product and sample protection against UV over exposure.
• For safety UV-opaque and resistant 99.99%, thick acryl front, back and sides.
• Automatic UV lamp safety shut OFF, in case the door is opened, which prevents
accidental UV exposure.
• 304 grade stainless steel Work Surface - Highly durable and rust free work zone, made
for easy cleaning. (UVC Models)
• Self-protection against over-current.
Digital Controller
Air Flow
Additional Features
Filtration features (PW-Models)
• Particle-free ISO 14644-1 HEPA filter (Class 4 conditions)
- Using a 99.99%, efficiency HEPA filter that filters particle sizes of 0.3 micron and
greater, traps biohazardous aerosols, and provides a particulate-free work environments that minimizes cross contamination.
• Neoprene gaskets ensures that the HEPA filter is airtight to the body unit.
- The HEPA filters life span depending on the test room conditions has a life span of
3 years.
• Replacing of the HEPA filter can easily be replaced by opening the upper cover,
located in the front.
• Polyester fiber Pre Filter that has minimal pressure loss and 85% arrestance on the
A.F.L. test which serves to trap larger particles and increases the life of the main filter.
• Adjustable digital blower speed switch located in the front with use of large capacity
blower is adopted into the equipment.
UV Sterilization cabinet
Digital Controller
37
F
Fume Hoods
PCR Workstations & UV Sterilization cabinets
Specifications & Ordering Information
PCR Workstations
Model
PW-01
PW-11
Max. Air Volume (cmh / cfm)
557 / 327
697 / 408
Min. Air Volume (cmh / cfm)
167 / 97
209 / 121
929 / 546
279 / 162
0.3 / 60
Laminar Airflow Velocity (m / s / fpm)
ISO 14644-1Class 4
Air Cleanliness
Filter
Typical efficiency of 99.99% at 0.3 ㎛ US MIL -STD -282
; Micro glass fiber Media, Particle board, AL separator, Neoprene gaskets
HEPA Filter
Polyester fibers with an efficiency of 85% (A·F·I TEST); AL frame, Polyester fiber media
Pre Filter
Typically < 60 dBA at initial blower speed
Noise level (dBA)
Material
Acryl 8mm / 10mm (clear type)
Window (Front, Side / Back)
Illumination
Capacity
(W×D×H)
Acryl 10mm (clear type)
Work Surface
Intensity
Dimension
PW-21
Vertical
Air Flow Type
>1000
FL Lamp (lux)
165
185
330
15W×1EA
20W×1EA
30W×1EA
UV Density (㎼/cm2)
FL Lamp
15W×1EA
20W×1EA
30W×1EA
Interior (mm / inch)
700×585×602 / 27.5×23×23.7
880×585×602 / 34.6×23×23.7
1180×585×602 / 46.5×23×23.7
Exterior (mm / inch)
720×605×964 / 28×24×38
900×605×964 / 35.4×24×38
1200×605×964 / 47.2×24×38
UV Lamp
56.2 / 123.9
Net Weight (Body) (kg / lbs)
Electrical Requirements (230V)
Cat. No.
64.2 / 141.5
77.8 / 171.5
60Hz, 1.3A
50Hz, 1.3A
60Hz, 1.4A
50Hz, 1.4A
60Hz, 1.5A
50Hz, 1.5A
AAHB3001K
AAHB3002K
AAHB3011K
AAHB3012K
AAHB3021K
AAHB3022K
Electrical Requirements (120V)
Cat. No.
60Hz, 2.2A
60Hz, 2.7A
60Hz, 2.9A
AAHB3003U
AAHB3013U
AAHB3023U
Specifications & Ordering Information
UV Sterilization cabinets
Model
Intensity
Illumination
Capacity
Material
Dimension
(W×D×H)
UVC-01
UVC-21
>800
>900
>1000
UV Density (㎼ / ㎠)
150
385
450
Fl Lamp
8W×1ea
15W×1ea
20W×1ea
UV Lamp
8W×1ea
15W×1ea
20W×1ea
Stainless steel grade 304
Work Surface
Acryl 5 mm (clear type)
Window (Front, Back / Side)
Interior (mm / inch)
433×500×468 / 17.0×19.7×18.4
583×500×468 / 23×19.7×18.4
880×500×468 / 34.6×19.7×18.4
Exterior (mm / inch)
450×509×610 / 17.7×20×24
600×509×610 / 23.6×20×24
900×509×610 / 35.4×20×24
Net Weight (Body) (kg / lbs)
15 / 33.1
17.5 / 38.6
20 / 44.1
Electrical Requirements (230V)
60Hz, 0.1A
50Hz, 0.1A
60Hz, 0.2A
50Hz, 0.2A
60Hz, 0.3A
50Hz, 0.3A
Cat. No.
AAHB4001K
AAHB4002K
AAHB4011K
AAHB4012K
AAHB4021K
AAHB4022K
Electrical Requirements (120V)
Cat. No.
※ Above specifications can be changed without prior notice.
38
UVC-11
Fl Lamp (Lux)
60Hz, 0.2A
60Hz, 0.4A
60Hz, 0.6A
AAHB4003U
AAHB4013U
AAHB4023U
Fume Hoods
Accessories & Options
for PCR Workstaions & UV Sterilization Cabinets
General UV Dose and Time Required
Average UV Dose
Required
Pathogen
(㎼ . s/㎠)
PW-01
165
Average UV Time Required (㎼/ ㎠ /sec.)
UVC-01
PW-11
UVC-11
PW-21
150
185
385
330
UVC-21
450
S. enteritidis
4,000
25
27
22
10
13
B. megatherium sp. (spores)
2,730
17
18
15
7
9
9
6
B. subtilis
7,100
43
47
39
18
22
16
Eberthella typhosa
2,140
13
14
12
6
7
5
Escherichia coli (E. coli)
3,000
19
20
17
8
10
7
Micrococcus candidus
6,050
37
40
33
16
19
13
Proteus vulgaris
2,640
16
18
15
7
8
6
Pseudomonas aeruginosa
5,500
34
37
30
14
17
12
Pseudomonas aeruginosa
3,500
22
23
19
9
11
8
S. typhimurium
8,000
49
53
44
21
25
18
Shigella paradysenteriae
1,680
101
11
10
4
6
4
Spirillum rubrum
4,400
27
29
24
11
14
10
Staphylococcus albus
1,840
12
12
10
5
6
4
* Permissible environmental conditions: temperature (20 to 25℃) and relative humidity (up to 60%).
* Above listed applications are for general purpose use.
for PCR Workstations
Cat. No.
Description
HEPA Filter
PW-11
PW-21
EDA9221
PW-01
CHE4436
CHE4410
Lighting Lamp
HEPA Filter
PW-11
PW-21
CHE4409
PW-01
CHE4431
CHE4427
Suitable for
PW-01
EDA9219
EDA9220
Filters (PW Models)
UV Lamp
PW-11
PW-21
CHE4423
Pre Filter
for UV Sterilization Cabinets
Cat. No.
Description
Lighting Lamp
UVC-01
CHE4434
CHE4427
UVC-11
UVC-21
CHE4410
CHE4431
Suitable for
UVC-01
CHE4435
CHE4436
Lamps (PW and UVC Models)
UV Lamp
UVC-11
UV Lamp
UVC-21
Fluorescent Lamp
39