thermocool® sf
THERMOCOOL SF THERMOCOOL SF CATHETER CATHETER CATHETER THERMO HERMOC COOL OOL SF SF T ® ® SYSTEM SYSTEM ThermoCool Catheter with Surround Flow technology optimizes cooling ® Uniform cooling across the entire catheter tip •Unlike traditional irrigated technologies that only cool locally, our cutting-edge design and porous tip technology allow for uniform cooling of the entire catheter tip •The strategically placed holes around the entire surface area of the tip achieve maximum cooling efficiency regardless of your catheter orientation •The centralized position of the Carto® System Sensor allows for uniform flow within the tip •Fluid diverters ensure fluid reaches all areas of the tip at even pressure Half the flow rate THERMOCOOL SF ® CATHETER CATHETER SYSTEM CATHETER ThermoCool® SF Bi-Directional NAV Catheter Ordering #* Curve Type French Size # of (F) Electrodes Electrode Spacing (mm) Tip Electrode Temperature (mm) Sensor Length (cm) BNI35BBH BNI35BDH BNI35BFH BNI35DDH BNI35DFH BNI35DJH BNI35FFH BNI35FJH BNI35JJH 2-5-2 2-5-2 2-5-2 2-5-2 2-5-2 2-5-2 2-5-2 2-5-2 2-5-2 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 115 115 115 115 115 115 115 115 115 BB BD BF DD DF DJ FF FJ JJ 8 8 8 8 8 8 8 8 8 4 + 2 4 + 2 4 + 2 4 + 2 4 + 2 4 + 2 4 + 2 4 + 2 4 + 2 Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Associated Cable US Ordering # EU Ordering # Product Description C5MHNAVMHS CR3425CT 39E-58M CR3425CT Cable from Catheter to Carto® XP System Patient Interface Unit Cable from Catheter to Carto® 3 System Patient Interface Unit ThermoCool® SF Bi-Directional Catheter Ordering #* Curve Type French Size # of (F) Electrodes Electrode Spacing (mm) Tip Electrode Temperature (mm) Sensor Length (cm) BDI35BBRT BDI35BDRT BDI35BFRT BDI35DDRT BDI35DFRT BDI35DJRT BDI35FFRT BDI35FJRT BDI35JJRT 2-5-2 2-5-2 2-5-2 2-5-2 2-5-2 2-5-2 2-5-2 2-5-2 2-5-2 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 115 115 115 115 115 115 115 115 115 BB BD BF DD DF DJ FF FJ JJ 8 8 8 8 8 8 8 8 8 4 + 2 4 + 2 4 + 2 4 + 2 4 + 2 4 + 2 4 + 2 4 + 2 4 + 2 Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Associated Cable US Ordering # •Thin-wall, hollow tip design promotes highly efficient internal and external cooling •Porous tip allows for even cooling HERMOCOOL SF • As a result, onlyT half the flow rate is required EU Ordering # C10MR10MSTKS 39E-43R Product Description Cable from Catheter to Stockert RF Generator Never lose your cool *US and European ordering number. SYSTEM Biosense Webster, Inc. 3333 Diamond Canyon Road Diamond Bar, CA 91765, USA Tel: 909-839-8500 Tel: 800-729-9010 Fax: 909-468-2905 www.biosensewebster.com Biosense Webster A Division of Johnson & Johnson Medical NV/SA Drève Richelle 161 Building H B-1410 Waterloo, Belgium Tel: 32-2-352-1411 Fax: 32-2-352-1492 ® CATHETER SYSTEM THERMOCOOL SF ® CATHETER THERMOCOOL SF Uniform cooling with half the flow rate* SYSTEM ® CATHETER THERMOCOOL SF ® SYSTEM CATHETER b i o s e n s ew eb s t e r. c o m I d e a s m a k i n g a d i f f e r e n c e™ *When compared to the ThermoCool® Catheter. OCOOL CATHETER SF THERMOCOOL SF ® SYSTEM CATHETER Innovative catheter design ThermoCool® SF Catheter—The catheter for your ablation procedures Control the power, control the lesion Biosense Webster’s new ThermoCool® Catheter with Surround Flow technology simplifies ablation procedures by providing uniform cooling at half the flow rate* Ideal for use in AF procedures Efficient uniform tip cooling •Porous tip provides uniform cooling •Easier fluid management due to half the flow rate • Low risk of thrombus formation •ThermoCool® Catheter with Surround Flow 20W at 60 sec* technology allows for uniform and efficient cooling of the entire catheter tip during ablation 42˚C tip-to-tissue interface In VT, ThermoCool® SF Catheter provides the power needed to create the lesions you want to create the lesion you want 73˚C 3 mm depth •Designed to achieve the level and duration of power necessary 50˚C 7 mm depth to create successful lesions •Avoids high tip-to-tissue interface temperature •Allows delivery of the desired energy 30˚C catheter tip •Less fluid delivered to patients, which is critical in VT patients with poor left ventricular function Temperature remains constant during ablation* Simple and powerful enough to use in atrial flutter • High cooling efficiency of ThermoCool® SF Catheter means that •3.5 mm tip—with no tradeoffs between power and signal resolution there is no tip temperature rise during ablation •Uniform cooling provides high efficiency RF delivery to achieve isthmus block Phase 0 Phase 1 Phase 2 Phase 3 Phase 4 Mapping Pre-RF high flow rate RF ablation Post-RF high flow rate Mapping Traditional Irrigated Catheter THERMOCOOL® Catheter SYSTEM THERMOCOOL SF ® CATHETER SYSTEM THERMOCOOL SF ® CATHETER Compatible with Carto® XP and Carto® 3. Image courtesy of Southlake Regional Health Centre, Canada No lesion *When compared to the ThermoCool® Catheter. Lesion forms continually while the generator is delivering energy *Thigh preparation testing with the ThermoCool® SF Catheter, parallel position, and 10 g contact force. The exact temperatures cannot be translated directly to the in vivo conditions. SYSTEM continues toSF grow minimally THERMOCOOLLesion ® No additional lesion growth CATHETER THERMOCOOL SF ® SYSTEM CATHETER
Similar documents
Individual Order Form Instructions
Individual Order Form Instructions Cake & Pie Pans 1J
More information