SafeAir Smoke Evacuator

Transcription

SafeAir Smoke Evacuator
SafeAir Smoke Evacuator – Silent. Powerful. Responding immediately. Breathe the difference!
SafeAir Smoke Pencil
SafeAir Smoke Evacuator
Electrosurgery without
smoke is possible
To bring all the power of SafeAir Smoke
Evacuator to the surgical field.
SafeAir Smoke Pencils are single use electrosurgical pencils, with a fully integrated smoke
evacuation function. With SafeAir Smoke
Pencil, surgical smoke is gone.
SafeAir Smoke Evacuator – technical specifications
Classification
Class I, type B
Protection class
IP 21, normal tight
Network voltage
220-240VAC – 50 Hz
Power consumption
In operation: 250W
Standby: 14W
Fuses
2 x T 4AH / 250VAC ceramic fuses
Suction capacity at the tip of the SafeAir
Smoke Pencil
High suction Approx. 96 l/min
Low suction Approx. 45 l/min
Vacuum
150 mbar
Level of noise
46 dBa
Filter
ULPA with active carbon
Dimensions
450 x 430 x 205mm
Weight
26,5kg
Ordering informations
Ref.: SFR-0200
SafeAir Smoke Evacuator
Incl. 1 ULPA filter with active carbon, user’s instruction
and quick reference guide
1 piece
SafeAir Smoke Evacuator
l
Dammstrasse 19
CH-6301 Zug
Switzerland
l
P: +41 41 723 2630
E: +41 41 723 2635
VAT: CHE-299.243.601
l
E: info@safeair.ch
www.safeair.ch
SafeAir is a trademark of SafeAir AG Copyright SafeAir 2012
BV0138A-UK-2012
Surgery without smoke
SafeAir AG
Surgery without smoke
SafeAir Smoke Evacuator – Silent. Powerful. Responding immediately. Breathe the difference!
Surgical smoke is a hazard in the
Operating Room
Surgical plumes contain toxic gases and viable cellular material that might carry infectious
agents. The plumes should be evacuated from the OR. The best capture is achieved with an
electrosurgery pencil providing aspiration of smoke within 2 cm of the source.
4”Surgical smoke and infection control” – Alp E, Biji D, Bleichrodt RP, Hansson A, Voss A.
– J Hosp Infect. 2006; 62:1-5
4”The Hazards of Surgical Smoke”, Brenda C. Ulmer, AORN Journal, 2008, 87(4), 721-738
4Hazard control 11 (HC11) – NIOSH – Publication no. 96-128 – September 1996
4”Randomized clinical trial of suction versus standard clearance of the diathermy plume”,
S. H. Pillinger, L. Delbridge and D. R. Lewis, British Journal of Surgery 2003; 90: 1068–1071
4”IFPN Guideline on Smoke Plume”, IFPN, 2009
Captures smoke as soon as it appears
SafeAir Smoke Evacuator integrates a specific vacuum technology that provides:
4 P
owerful aspiration even through tubings with reduced lumen
The important factor for efficient smoke evacuation is how much aspiration flow the pump
can generate at the source of smoke, i.e. within 2 cm of the tip of the diathermy electrode.
That’s where SafeAir Smoke Evacuator makes a difference. Connected to a SafeAir Smoke
Pencil, it provides an aspiration of 96 l/min where the smoke appears.
4 Immediate respons with maximum power
The vacuum technology of SafeAir Smoke Evacuator is able to deliver its maximum aspiration power within tenth of a second of the activation. As a result, even the very first plumes generated are captured, and will not propagate in the OR; series of rapid diathermy
burns will not spread the acrid smell neither.
Designed with your working
environment in mind
5
Easy to use
The front panel has a user-friendly interface
with touch buttons and clear indicators for
the main functions. The overall surface is
flat, smooth and easy to clean.
5
Silent
The vacuum technology is silent by itself. To
further reduce the noise, a silencer is added
to the outcast of the machine.
In addition, SafeAir Smoke Evacutor can be
synchronised with any ESU simply by running the cable of the handpiece through a
sensor.
5
Effective
SafeAir Smoke Evacuator
comes with an ULPA filter with
active carbone that removes
chemicals and the acrid smell.
5
The filter has a lifetime
of 5 hours of effective
use, that can be easily
followed on a display
on the front panel.
5
Additionally, SafeAir Smoke Evacuator
provides:
• 2 levels of aspiration power
• 3 modes of actions: synchronized, permanent, foot pedal
• An adjustable shut-off delay (0-6 sec)
• An easy access to maintenance data with
a software downloadable from SafeAir
web site.