SafeAir Smoke Evacuator
Transcription
SafeAir Smoke Evacuator
SafeAir Smoke Evacuator – Silent. Powerful. Responding immediately. Breathe the difference! SafeAir Smoke Pencil SafeAir Smoke Evacuator Electrosurgery without smoke is possible To bring all the power of SafeAir Smoke Evacuator to the surgical field. SafeAir Smoke Pencils are single use electrosurgical pencils, with a fully integrated smoke evacuation function. With SafeAir Smoke Pencil, surgical smoke is gone. SafeAir Smoke Evacuator – technical specifications Classification Class I, type B Protection class IP 21, normal tight Network voltage 220-240VAC – 50 Hz Power consumption In operation: 250W Standby: 14W Fuses 2 x T 4AH / 250VAC ceramic fuses Suction capacity at the tip of the SafeAir Smoke Pencil High suction Approx. 96 l/min Low suction Approx. 45 l/min Vacuum 150 mbar Level of noise 46 dBa Filter ULPA with active carbon Dimensions 450 x 430 x 205mm Weight 26,5kg Ordering informations Ref.: SFR-0200 SafeAir Smoke Evacuator Incl. 1 ULPA filter with active carbon, user’s instruction and quick reference guide 1 piece SafeAir Smoke Evacuator l Dammstrasse 19 CH-6301 Zug Switzerland l P: +41 41 723 2630 E: +41 41 723 2635 VAT: CHE-299.243.601 l E: info@safeair.ch www.safeair.ch SafeAir is a trademark of SafeAir AG Copyright SafeAir 2012 BV0138A-UK-2012 Surgery without smoke SafeAir AG Surgery without smoke SafeAir Smoke Evacuator – Silent. Powerful. Responding immediately. Breathe the difference! Surgical smoke is a hazard in the Operating Room Surgical plumes contain toxic gases and viable cellular material that might carry infectious agents. The plumes should be evacuated from the OR. The best capture is achieved with an electrosurgery pencil providing aspiration of smoke within 2 cm of the source. 4”Surgical smoke and infection control” – Alp E, Biji D, Bleichrodt RP, Hansson A, Voss A. – J Hosp Infect. 2006; 62:1-5 4”The Hazards of Surgical Smoke”, Brenda C. Ulmer, AORN Journal, 2008, 87(4), 721-738 4Hazard control 11 (HC11) – NIOSH – Publication no. 96-128 – September 1996 4”Randomized clinical trial of suction versus standard clearance of the diathermy plume”, S. H. Pillinger, L. Delbridge and D. R. Lewis, British Journal of Surgery 2003; 90: 1068–1071 4”IFPN Guideline on Smoke Plume”, IFPN, 2009 Captures smoke as soon as it appears SafeAir Smoke Evacuator integrates a specific vacuum technology that provides: 4 P owerful aspiration even through tubings with reduced lumen The important factor for efficient smoke evacuation is how much aspiration flow the pump can generate at the source of smoke, i.e. within 2 cm of the tip of the diathermy electrode. That’s where SafeAir Smoke Evacuator makes a difference. Connected to a SafeAir Smoke Pencil, it provides an aspiration of 96 l/min where the smoke appears. 4 Immediate respons with maximum power The vacuum technology of SafeAir Smoke Evacuator is able to deliver its maximum aspiration power within tenth of a second of the activation. As a result, even the very first plumes generated are captured, and will not propagate in the OR; series of rapid diathermy burns will not spread the acrid smell neither. Designed with your working environment in mind 5 Easy to use The front panel has a user-friendly interface with touch buttons and clear indicators for the main functions. The overall surface is flat, smooth and easy to clean. 5 Silent The vacuum technology is silent by itself. To further reduce the noise, a silencer is added to the outcast of the machine. In addition, SafeAir Smoke Evacutor can be synchronised with any ESU simply by running the cable of the handpiece through a sensor. 5 Effective SafeAir Smoke Evacuator comes with an ULPA filter with active carbone that removes chemicals and the acrid smell. 5 The filter has a lifetime of 5 hours of effective use, that can be easily followed on a display on the front panel. 5 Additionally, SafeAir Smoke Evacuator provides: • 2 levels of aspiration power • 3 modes of actions: synchronized, permanent, foot pedal • An adjustable shut-off delay (0-6 sec) • An easy access to maintenance data with a software downloadable from SafeAir web site.