FLOWAY
Transcription
FLOWAY
Dual-flow AHU FLOWAY The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution Air flow rate: Use FLOWAY is a PLUG & PLAY dual-flow ventilation unit equipped with a highly efficient heat recovery unit with plug fans and high performance EC motors, designed to meet all the requirements of recent thermal regulations. Unit supplied ready to use, prewired, preprogrammed in the factory and supplied with a remote control. FLOWAY draws clean, fresh air indoors using, on average, 80% less energy than that needed for air conditioning (cooling and heating). These machines are designed for use in the following applications: é Service sector Buildings: o Administrative buildings, Offices o Education facilities, libraries, community centres o Cafés, hotels, restaurants Range 500 to 8500 m3/h o Shops o Nursing homes, healthcare facilities o Collective housing é All facilities where ventilation is required. Classic model: 9 sizes, air flow from 300 to 8500 m3/h. Floor-mounted horizontal unit with horizontal air flows and air connections on the sides. Vertical model: 4 sizes, air flow from 300 to 2600 m3/h. Floor-mounted vertical unit with vertical air flows and air connections on the top. Ceiling-mounted model: 3 sizes, air flow from 300 to 1900 m3/h. Ceiling-mounted horizontal unit with vertical air flows and air connections on the sides. FLOWAY "Classic" MODELS 1000 1500 2000 2500 3000 4000 5000 6000 7500 Nominal Flow Rate (m3/h) 1000 1500 2000 2500 3000 4000 5000 6000 7500 Max. power* (Kw) 2 x 0.42 2 x 0.99 2 x 0.99 2 x 1.7 2 x 1.7 2 x 1.85 2 x 1.85 2 x 2.73 2 x 2.73 Max current* (A) 6,2 3,6 3,6 5,5 5,5 6,1 6,1 8,7 8,7 Voltage (V) 1-Ph 230 3-Ph 400 3-Ph 400 3-Ph 400 3-Ph 400 3-Ph 400 3-Ph 400 3-Ph 400 3-Ph 400 Nominal Flow Rate (m3/h) 700 1000 1500 2000 Max. power* (Kw) 2 x 0.42 2 x 0.42 2 x 0.99 2 x 0.99 Max current* (A) 6,2 6,2 3,6 3,6 Voltage (V) 1-Ph 230 1-Ph 230 3-Ph 400 3-Ph 400 Max. power* (Kw) 2 x 0.42 2 x 0.42 2 x 0.99 Max current* (A) 6,2 6,2 3,6 Voltage (V) 1-Ph 230 1-Ph 230 3-Ph 400 FLOWAY "Vertical" MODELS 700 1000 1500 2000 FLOWAY "Ceiling-mounted version" MODELS 700 1200 1600 Nominal Flow Rate (m3/h) 700 1200 1600 * These values are given as a guide for a dual-flow unit fitted as standard, without standard option (electric heater). HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A 1 Dual-flow AHU FLOWAY Electric heaters nElectric elements encased in a copper finned layer to ensure uniform distribution of heat. nHigh-limit safety thermostat with automatic and manual reset. nControl by 2-stage on/off operation (3 stages, depending on the model) fully controlled by "Floway Control". MODELS Classic 1000 Vertical 700 & 1000 Ceiling-mounted 700 & 1200 Classic 1500 Vertical 1500 (external) Ceiling-mounted 1600 Vertical 1500 (internal) Classic 2000 & 2500 Classic 3000 Classic 4000 Classic 5000 Classic 6000 Classic 7500 Power (kW) Voltage (V) Current (A) 4,5 1-Ph 230 20 7,2 3-Ph 400 11 8,1 10,8 12,6 16,8 19,8 22,8 31,2 3-Ph 400 3-Ph 400 3-Ph 400 3-Ph 400 3-Ph 400 3-Ph 400 3-Ph 400 12 16 19 25 29 34 46 Description Casing nDouble-skin panels made from sheet steel, galvanised on both sides, thickness 8/10 mm. nRAL 7035 and RAL 7024 grey lacquer coated finish on external panels. nM0/A1 fire rating nMineral wool, thickness 50 mm. Filtration nF5, F7, F8 or F9 filters. nFilter cells kept compressed by a special system to ensure a leaktight seal. nFilter fouling value monitored by analogue sensor and displayed by controller. Ventilation n"Plug Fan" type direct drive FMA. nPlug fan driven by an electronically commutated motor with built-in speed control. Heat recovery units nCounter-flow plate heat exchanger with motorised partial bypass (ceiling-mounted and vertical models). é Efficiency greater than 80% across the range of air flows. nRotary heat exchanger equipped with speed control ("Classic" model). é Efficiency greater than 80% at nominal flow rate. Electrics box nElectrics box for power, control and internal regulation of the unit, comprising: -P ower supply (3-Ph/400 V/Earth or 1-Ph/230 V/Earth). -M ain disconnect switch. -P rotected transformer. - Protection and control of all electrical components by a circuit-breaker and contact switch. -P eripheral options and power terminal block. -C ontrol by factory pre-programmed CAREL pCO3 PLC. - Hand-held cabled micro-terminal (cable length provided: 6 m). - Fault summary contact. - 3 temperature sensors. - 4 pressure sensors. Accessories Damper with airfoil blades driven by an on/off spring-return actuator. Flexible sleeve Adjustable feet CO2 air quality sensor Sound trap Roof Canopy Mixing section Indoor environment switch Hydraulic Coil Copper pipes, aluminium fins. nCoil can be integrated or additional (cased) nWith the accessory fitted, 3-way control valve and 0-10V actuator controlled by "Floway Control" for setpoint accuracy. nGalvanised condensate drain pan (cooling coil or mixed coil only). 2 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A Dual-flow AHU Control FLOWAY Control "FLOWAY CONTROL" control function (software V2.2) Fan Timer programming Safety Alarms Control mode Hot air and/or Cold air production Free cooling operation Night cooling operation Included Options* Integrated clock: management in series 4 events per year, and per week and per day X Frost protection By Fresh Air Temperature control By Exhaust air flow pressure on heat recovery unit delta control (pressure sensor) X X Monitoring of sensor status Monitoring operation values (thresholds) Operating control of EC fan motor assemblies via a fault summary contact "Control of filter fouling (automatic calculation of "Dirty filter" and "Blocked filter" alarm thresholds) Main and ordinary fault summary Fire monitoring (potential free (dry) contact available (normally closed)) Management of alarms and log (100) Control of return air or supply air temperature X X X X X X X X Regulated temperature control based on Outdoor temperature X Control of room temperature with a room terminal (Th-Tune) Gradual action on the 3V hydraulic coil control valve Gradual action on the electric heater TRIAC On/Off action on the various stages of the electric heaters Rotary heat exchanger stop (CLASSIC model) Open bypass on counter flow plate recovery unit (VERTICAL & CEILING-MOUNTED model) Rotary heat exchanger stop (CLASSIC model) Open bypass on counter flow plate recovery unit (VERTICAL & CEILING-MOUNTED model) X X X X X X X X Morning heating operation Control degree of opening of mixing bypass (CLASSIC model) X ECO recirculation operation Control degree of opening of mixing bypass (CLASSIC model) X Optimisation of output Configuration of the air flow rate Variation of the rotation speed of the rotary recovery unit (CLASSIC model) 2 air flow rate setpoints per air flow Display of the air flow rate Overpressure/negative pressure management Constant flow rate operation Keeps the air flow rate constant regardless of how fouled the filters are Modulation of flow rates operation Communicating mode Miscellaneous CO2 sensor Presence contact contact External contact Multi zone Intake duct constant pressure operation MODBUS protocol LON protocol Management by CMS KNX protocol TCP/IP protocol Languages supported (French/English/German/Dutch/Spanish/Italian) Integrated temperature sensors (*3: fresh air supply and extraction, exhaust air extraction) Integrated pressure sensors (*4: fresh air and exhaust air filter fouling level, fresh air and exhaust air fan) Damper control Information provided to the user via the hand-held micro terminal Contact for controlling the pumps for the hydraulic coils (with operating control) Contact for controlling an external outdoor heat production system (boiler, etc.) Contact for controlling a humidifier Single zone X X X X X signal 0-10V X X X X X X X X X X X X X X X X Option*: Requires the component to be selected as an option_damper, coil, CO2 sensor,... HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A 3 FLOWAY FLOWAY features, as standard, an electrics box equipped with a factory-programmed PLC and a hand-held micro-terminal. Dual-flow AHU Dimensions FLOWAY and directions of air flows FLOWAY "CLASSIC" MODELS DIMENSIONS Length 1360 557+847 557+847 800+800 800+800 800+800 800+800 800+800 800+800 Height 908 1158 1158 1359 1359 1659 1659 1959 1959 1000 1500 2000 2500 3000 4000 5000 6000 7500 * Without internal option WEIGHT * Width 810 1010 1010 1210 1210 1510 1510 1810 1810 201 303 309 413 432 558 604 702 751 Size 1000 Sizes 1500 and 2000 1404 1009 404 303 1310 302 271 47.2 1073 1159 85 421 467 55 n3 55 n3 Sizes 2500 to 7500 B D A E C MODELS 2500 3000 4000 5000 6000 7500 4 A 1600 1600 1600 1600 1600 1600 B 1210 1210 1510 1510 1810 1810 Dimensions (mm) C 1359 1359 1659 1659 1959 1959 D 990 990 1284 1284 1584 1584 E 510 510 612 612 762 762 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A Dual-flow AHU FLOWAY Direction of air flow ROTS 1.1 ROTS 2.2 ROTS 1.2 ROTS 2.1 WHITE ARROW = FRESH AIR BLACK ARROW = EXTRACTED AIR HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A 5 Dual-flow AHU FLOWAY FLOWAY "VERTICAL" DIMENSIONS MODELS Height 1385 1526 1758 1901 700 1000 1500 2000 Length 1313 1456 1593 1735 WEIGHT * Width 730 730 832 832 202 243 330 389 Ø 16 mm condensate drain pipe * Without internal option Size 700 1313 730 702 47 1270 584.5 193 231 492.5 n250 239 1238 n2 50 50 n2 70 231 1385 1338 n250 6 n4 584.5 492.5 100 272 193 124 Size 1000 1456 730 701 47 1411 660 222 n315 231 529 239 1379 15 n3 231 70 223 660 529 313 n46 100 1526 5 n315 1479 n3 1 124 6 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A Dual-flow AHU Size 1500 1550 805 730 248 253 572 n355 295 1611 n35 5 55 n3 70 253 1758 1711 n355 248 730 572 100 349 6 n4 124 Size 2000 832 1735 805 47 1692 620 824 253 n35 5 n35 5 70 253 1754 295 n35 5 824 620 385 248 n35 5 100 1901 1854 n46 248 124 WHITE ARROW = FRESH AIR BLACK ARROW = EXTRACTED AIR HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A 7 FLOWAY 832 47 1593 Dual-flow AHU FLOWAY FLOWAY "CEILING-MOUNTED VERSION" DIMENSIONS MODELS Height 585 585 585 700 1200 1600 Length 1453 1592 1850 WEIGHT Width 896 1174 1456 161 206 279 Ø 16 mm condensate drain pipe Size 700 WHITE ARROW = FRESH AIR BLACK ARROW = EXTRACTED AIR n Size 1200 1498 1224 1174 1202 47 1592 280 8 938 280 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A 47 Dual-flow AHU n13 .5 Size 1600 WHITE ARROW = FRESH AIR 1456 1484 1506 FLOWAY BLACK ARROW = EXTRACTED AIR 47 1762 47 1856 280 601 280 B 253 A 601 6 n1 474.5 AIR CIRCULATION DIMENSIONS (mm) A B C D 700 306 306 Ø160 Ø315 1200 398 398 Ø250 Ø355 1600 499.5 499.5 Ø250 Ø400 71 C C D MODELS HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A 9 Dual-flow AHU FLOWAY ADDITIONAL CASING (MUST ONLY BE POSITIONED IN A HORIZONTAL AIR FLOW.) Additional casing size Weight (kg) Classic 1000 Vertical 700 & 1000 Ceiling-mounted 700 Size1 496x809x543 49 Kg Classic 1500 & 2000 Vertical 1500 & 2000 Ceiling-mounted 1200 & 1600 Size 2 495x1009x642 64 Kg Classic 2500 & 3000 Size3 400x759x1210 68 Kg Classic 4000 & 5000 Size 4 400x909x1510 88 Kg Classic 6000 & 7500 Size 5 400x1069x1810 112 Kg FLOWAY MODELS Size 1 Size 2 1009 809 504 405 505 321 371 221 271 404 Size 3 Size 4 793 759 906 1510 1210 Size 5 1069 1810 10 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A Dual-flow AHU Classic model performance Operating pressure = f(flow) Pa 1000 FLOWAY 800 3000 5000 2500 500 2000 4000 1500 1000 300 7500 6000 100 500 0.278 1000 1500 2000 2500 0.556 3000 3500 0.833 4000 1.111 4500 5000 5500 1.389 6000 1.667 6500 7000 7500 8000 1.944 m 3/h 8500 2.222 9000 m 3/s Performancerecov = f(flow) % Clean F7 filter Heat recovery unit conditions: 0°C / 90% & 20°C / 50% 90 86 82 78 7500 5000 3000 1000 2000 74 6000 4000 2500 1500 70 500 1000 0.278 SFPby 1500 2000 2500 0.556 fan m 3/h 3000 0.833 3500 4000 1.111 4500 5000 5500 1.389 6000 1.667 6500 7000 1.944 7500 8000 8500 2.222 9000 m 3/h = f(flow) W/(m3/h) 0.35 Clean F7 filter Heat recovery unit conditions: 0°C / 90% & 20°C / 50% Duct pressure: 200Pa SFPv=0.3 W/(m3/h) RT reference output 1500 2000 1000 5000 3000 0.25 6000 4000 2500 7500 0.15 500 0.278 1000 1500 0.556 2000 2500 0.833 3000 3500 1.111 4000 4500 1.389 5000 5500 1.667 6000 6500 1.944 7000 7500 8000 2.222 m 3/s HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A 8500 9000 m3/h 11 Dual-flow AHU FLOWAY “Vertical” model performance Operating pressure = f(flow) Pa 1000 0.139 0.417 0.278 0.694 0.556 m3/s 800 1500 500 1000 700 2000 300 100 500 1000 1500 2000 2500 m3/h Performancerecov = f(flow) % 0.139 0.278 0.556 0.417 0.694 m3/s Clean F7 filter Heat recovery unit conditions: 0°C / 90% & 20°C / 50% 88 84 1000 700 1500 2000 80 500 SFPby 1000 fan 1500 2000 0.417 0.556 m3/h 2500 = f(flow) W/(m3/h) 0.139 0.35 0.278 0.694 m3/s Clean F7 filter Heat recovery unit conditions: 0°C / 90% & 20°C / 50% Duct pressure: 200Pa SFPv=0.3 W/(m3/h) RT reference output 2000 1500 0.25 700 1000 0.15 500 12 1000 1500 2000 2500 m3/h HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A Dual-flow AHU Ceiling model performance Operating pressure = f(flow) 0.139 1000 m3/s 0.417 0.278 0.556 FLOWAY Pa 800 1600 500 1200 700 300 100 500 1000 1500 m3/h 2000 Performancerecov = f(flow) % 88 m3/s 0.278 0.139 0.556 0.417 Clean F7 filter Heat recovery unit conditions: 0°C / 90% & 20°C / 50% 86 84 82 700 1200 1600 80 500 SFPby 1000 fan 1500 2000 m3/h = f(flow) W/(m3/s) 0.35 0.139 0.278 m3/s 0.556 0.417 Clean F7 filter Heat recovery unit conditions: 0°C / 90% & 20°C / 50% Duct pressure: 200Pa =0.3 W/(m3/h) SFPv RT reference output 0.25 1600 1200 700 0.15 500 1000 1500 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A 2000 m3/h 13 Dual-flow AHU FLOWAY This document is not legally binding. As part of its policy for continual product improvement, CIAT reserves the right to make any technical modification it considers necessary without prior notice. Registered address Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42 Fax: +33 (0)4 79 42 42 10 info@ciat.fr - www.ciat.com CIAT Service Tel.: 08 11 65 98 98 (0.15 €/min) Fax: 08 26 10 13 63 (0.15 €/min) Compagnie Industrielle d’Applications Thermiques - S.A. with a registered capital of 26,728,480 € - R.C.S. Bourg-en-Bresse B 545 620 114 14 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A