ElectroVap ELMC2 Steam Bath Specification
Transcription
ElectroVap ELMC2 Steam Bath Specification
Technical manual Remote control for ElectroVap MC2 Steam Bath 1 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Contents Description 3-4 Dimensions & Installation 5 Electrical connections 6 to 8 Use & Settings 9 to 13 2 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Description 6 7 1 2 3 4 5 1. Steam Production Power On/Off Button 2. Date / Time Access Setting Button 3. Hammam light Power On/Off Button 4. Remote Control On/Off Button 5. 12 V Power Inlet Jack (for optional AC adaptor) 6. Navigation Pad 7. OK Button 3 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Description The Steam Bath MC Remote Control gives you distant control over your steam bath. Two models are available : Model 1 : includes the remote control, a 12V supply transformer, a 3 dry contact control board and a RS485 board. Model 1 is capable of : • powering manually on or off the steam production or automatically thanks to a weekly schedule (via terminals 3 & 4 of the steam bath); • Offering 3 dry contacts on the 3 contact control board (see under the list of possible functions). Model 2 : includes the remote control, a 12V supply transformer, a 8 dry contact control board and a RS485 board. This model is capable of : • powering manually on or off the steam production or automatically thanks to a weekly schedule (via terminals 3 & 4 of the steam bath); • Offering 8 dry contacts on the 8 contact control board (see under the list of possible functions). Remote control 230/12V Transformer RS485 board 3 dry contact board 8 dry contact board Possible actions with the Steam Bath MC Remote Control : • • • • • • Switching on and off the steam bath manually or on an automatic scheduled basis; Pre-set the desired room temperature; Select the perfume intensity (in case of a perfume device installation); Switching on or off room light(s); Switching on or off musics; Powering ventilation or exhausting air out of the room. 4 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Dimensions & Installation DIMENSIONS 95 223 86 35 27 • Weight = 370g INSTALLATION Remove the lateral screws of the Remote Control and dissemble the box. Set the bottom on wall at the desired place and mark one of the 4 holes. Drill a ø 3 or 4mm hole, insert peg and secure the bottom on wall with a screw. Make sure that the box is at level and mark up the other 3 holes. Take the bottom off wall and drill the holes, insert pegs and screws and screw them up . 1 Set back the Remote Control front panel and screw back the two lateral screws. The installation of the Remote Control is now completed. Please now wire and set the Steam Bath MC Remote Control. 5 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Electrical connexions The wiring of the equipment described under must be made with a 0.75 mm2 maximum flexible wire. STEAM BATH 12V TRANSFORMER Remote control board Ref: 500650/03 0 Transformer 220V/12V 100VA 0 12V 220V Terminals on DIN rail of the steam generator L Black terminal to plug on red terminal (s.a. attached picture) N 60 • Attach the 230/12V transformer inside the electrical compartment of the steam generator with the supplied set of bolts and nuts. • Connect transformer wires as per attached drawing. 61 Red terminal Red terminal to plug on On/Off switch 230/12V AC ADAPTOR Mains socket 230V 6 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Electrical connexions The wiring of the equipment described under must be made with a 0.75 mm2 maximum flexible wire. RS485 board Steam generator main board Ref: 500101/05 RS485 board Ref: 500800/01 • • • Clamp the RS485 board onto the DIN rail of the steam generator. Connect the RS485 grey ply to the steam generator board Wire the RS485 3 pin connector to the Remote Control board J11 connector with reinforced wire as follows : 485+ on 2 485– on 1 GND on 3 Reinforced wire GND (reinforced) Remote control board Ref: 500650/03 GND (reinforced) 7 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Electrical connexions The wiring of the equipment described under must be made with a 0.75 mm2 maximum flexible wire. 3 CONTACT BOARD DEVATEC • Attach the 3 contact board onto the stand-offs located under the steam generator main board with M4 8mm long screws. • Connect the grey ply of the 3 contact board to the connector X18 of the steam generator main board. X4 Réf:500101-05 17 16 15 15V Transformer 115/15V X3 14 13 12 X18 11 • The 3 contact board makes possible to connect three optional devices on terminals : 30-31, 33-34 and 36-37 (NO contact) or terminals : 31-32, 34-35 and 37-38 (NF contact) (perfume device, disinfectant device, ventilation or other… ) X2 F1: 2A X12 F4:50mA 6 10 9 8 7 X1 Réf.: 500400-03 K20 X20 30 31 32 X23 K21 K22 NO NF NO NF NO NF X22 X21 36 37 38 33 34 35 37 36 34 33 31 30 30 31 32 8 CONTACT BOARD 33 34 35 36 37 38 • Attach the 8 contact board onto the stand-offs located under the steam generator main board with M4 8mm long screws. • Connect the grey plies of the 8 contact board to the connectors X16 & X18 of the steam generator main board. X16 DEVATEC REF: 500101_05 • The 8 contact board makes possible to connect eight optional devices on terminals : 1-2, 4-5, 7-8, 10-11, 13-14, 16-1/, 19-20 and 22-23 (NO contact) or terminals : 8-9, 11-12, 14-15 or 17-18 (NF contact) (perfume and disinfectant devices, ventilation, air exhaust, urgent stop or other… ) X18 NO NO 1 X11 4 5 19 20 22 23 NO NF X10 X12 DEVATEC REF: 500660/01 X9 RL3 RL5 RL4 RL6 NO RL1 RL2 X1 X2 1 2 2 NO NO 4 5 RL7 X3 X4 X5 X6 7 8 9 10 11 12 13 14 15 16 17 18 X7 19 20 NF NO NF NO RL8 7 X8 22 23 8 8 9 10 11 12 13 14 15 16 17 18 Pictures for illustrating purposes only NF STEAM BATH MC REMOTE CONTROL Use & Settings DISPLAY SYMBOLS 45°C Steam generator in run Hammam lighting on Steam generator on halt Hammam lighting off Room temperature Perfume on Music (option) Pre-set temperature Auto-timer Steam generator on-line Steam generator off-line DISPLAY READING 45°C 45°C - + Mo 00:00 9 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Use & Settings Day / time settings 45°C 45°C - + Mo 00:00 Pressing button 2 highlights the day and hour information. Press the « OK » button and set the day by pressing the up or down arrows of the navigation pad. Then use the right side arrow for selecting the hour digits and set the time with the up and down arrows of the navigation pad. Finally, use again the right side arrow for selecting the minute digits. Use the up and down arrows for increasing or decreasing the time. Press the « OK » button for validation and press again on button 2 for validation of the day and hour. 2 Auto timer Your steam generator can be weekly programmed to work on for a certain time at different time of a day and any day of the week. The following information will guide you on how to program your steam generator. 1. For entering the schedule menu, press both the right and left side arrows simultaneously. 10 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Use & Settings Auto timer setting Day Mo Tu We Th Fr : Steam unit status On 10:00 Working period time Su Sa to 15:00 Th 15:12 2. The first day is illuminated : press the down arrow to select the humidifier status. 3. The status line is illuminated : press the left or right arrow for setting the humidifier on on or off position. ou 4. Press the down arrow for setting the working time. 5. The working time is now illuminated : press the « OK » button. 6. For setting the period of time, press the up or down arrow. ou 7. For selecting the minutes, press the right side arrow. 8. For setting the minutes, press the up or down arrow. ou 9. Once the working time has been set, press the « OK » button and then press the down arrow. The working time is no longer illuminated. You can now set the working time for the following day by pressing the right side arrow. 10. Process the same way as above for programming the other days. 11. Press Button 2 to exit the program. 2 11 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Use & Settings Menu scrolling or Temperature setting point Number of lamps 22°C 22°C 45°C - 1 + Mo 09:00 Mo 09:00 or or ou Perfume intensity Music on or off 22°C - 22°C Off + Mo 09:00 Mo 09:00 or or 12 Pictures for illustrating purposes only STEAM BATH MC REMOTE CONTROL Use & Settings Option 1 setting Option 2 setting 22°C Opt 1 22°C Off Opt 2 Mo 09:00 Off Mo 09:00 or or Option 3 setting Remote control nb (if several remote controls) 22°C Opt 3 22°C Off Unit n° 1 Mo 09:00 Mo 09:00 or or 13 Pictures for illustrating purposes only Rue Feu St Eloi 76550 Ambrumesnil - France LR 94104-2 Export Division: tel. +33 (0)2 35 83 06 44 ou +33 (0)2 35 83 03 86 fax. +33 (0)2 35 85 36 72 Email: export@devatec.com - www.devatec.com devatec reserves the right to change specifications or design of the equipment described in this borchure without prior notice. 14 Pictures for illustrating purposes only