Manual - handv_man_variheat3_tech_issue33
Transcription
Manual - handv_man_variheat3_tech_issue33
Please read these instructions carefully as they will enable you to get maximum efficiency and reliability from your new Calorex Dehumidifier. Technical Manual VARIHEAT VH3 AA/AW600/900/1200A/BVHXF 1500BVHXF SD437360 iss 33 04/06/13 HEALTH AND SAFETY WARNING As the dehumidifier embodies electrical and rotational equipment, ONLY competent persons should carry out any work on this type of machine. (See Guarantee). Page 38 SD437360 ISSUE 33 CONTENTS 1.0 HOW THE CALOREX ‘SERIES 3 VARIHEAT’ SYSTEM WORKS. ................................................................. 3 1.1 OPERATION ................................................................................................................................. 4 2.0 INSTALLATION ........................................................................................................................................... 5 2.1 PLUMBING ................................................................................................................................... 9 2.2 DETERMINING WATER FLOW ................................................................................................... 10 2.3 WATER CONNECTIONS ............................................................................................................. 12 2.4 ELECTROLYTIC CORROSION IN SWIMMING POOLS ............................................................... 13 2.5 ELECTRICAL INSTALLATION..................................................................................................... 14 2.6 CIRCUIT DIAGRAMS .................................................................................................................. 18 2.7 REGULAR PLANNED MAINTENANCE ........................................................................................ 24 3.0 CONTROLS ............................................................................................................................................... 25 3.1 COMMISSIONING CHECKLIST ................................................................................................. 27 3.2.1 TIME CLOCK SETTINGS ......................................................................................................... 27 3.2.3 POOL & AIR TEMPERATURE AND HUMIDITY CONTROLS ..................................................... 29 4.0 DATA SHEET ............................................................................................................................................. 30 5.0 DIMENSION DRAWINGS ........................................................................................................................... 32 6.0 WARRANTY CONDITIONS ........................................................................................................................ 39 7.0 LOGIC CONTROL CIRCUITS .................................................................................................................... 40 7.1 RELAY FUNCTIONS .................................................................................................................. 46 7.2 PARAMETER SETTINGS ............................................................................................................ 47 8.0 SOUND GRAPH ........................................................................................................................................ 52 9.0 FAN CURVES ............................................................................................................................................ 56 10.0 REFRIGERATION DIAGRAMS ................................................................................................................. 59 11.0 SPARE PARTS LISTS ............................................................................................................................. 62 12.0 CONTROL PANELS ................................................................................................................................. 76 12.1 CONTROL PANEL REMOTE (OPTIONAL) ................................................................................. 78 13.0 FRIDGE BOX ASSEMBLIES .................................................................................................................... 81 13.1 MAIN FRIDGE COMPONENTS ALL MACHINES ....................................................................... 81 13.2 EXTRA PIPE WORK FITTINGS, AW600/900 MACHINES (NO LPHW) ...................................... 85 13.2 EXTRA PIPE WORK FITTINGS, AW1200/1500 MACHINES. .................................................... 87 13.3 EXTRA PIPE WORK FITTINGS, AW6/900 MACHINES WITH LPHW FITTED ........................... 89 13.4 EXTRA PIPE WORK FITTINGS, AW12/1500 MACHINES WITH LPHW FITTED ....................... 91 14.0 FAN BOX ASSEMBLY SPARE PARTS LIST ............................................................................................ 93 15.0 FINAL ASSEMBLY SPARE PARTS LIST TOP OUTLET ........................................................................... 96 16.0 FINAL ASSEMBLY SPARE PARTS LIST DOWN DRAUGHT .................................................................... 97 17.0 FRESH AIR BOX SPARE PARTS LIST .................................................................................................... 99 18.0 HEATER BOX ASSEMBLY SPARE PARTS LIST .................................................................................... 101 19.0 REMOTE SENSOR BOX ........................................................................................................................ 105 20.0 DUCT FLANGE KITS ............................................................................................................................. 106 21.0 FROST PROTECTION KITS .................................................................................................................. 107 22.0 PACKING SPECIFICATIONS ................................................................................................................. 109 Page 39 SD437360 ISSUE 33 Health and Safety This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 1.0 HOW THE CALOREX ‘SERIES 3 VARIHEAT’ SYSTEM WORKS. The Calorex ‘SERIES 3 VARIHEAT’ range consists of 4 models: 600/900/1200/1500. The model number increases in relation to the recirculated air flow from model 600 at 2000 m³/h to model 1500 at 4300 m³/h. All models are fitted with either one or two “console fixing service panels” These allow for the console to be fixed to the Variheat 3. These service panels can be fitted on any face of the machine. When optional fresh air box is fitted, all models have the facility to exhaust a percentage of the recirculating air and introduce a slightly lesser amount of fresh air (slight differential creates a negative pressure on pool hall to localise pool environment and protect the building fabric). An optional “negative pressure box” is also available. This exhausts a percentage of the circulationg air without introducing fresh air to the pool hall. All AW models are fitted with a fully controlled low pressure hot water air heating battery and a pool water heat exchanger. Provision is made for an external heat source to be initiated by the ‘SERIES 3 VARIHEAT’ controller. All AW models have air and water heat exchangers recovering energy from the refrigerated dehumidification process. These are also fully controlled with priority given to water. Optional, factory fitted frost protection kits are available, these kit protect the LPHW from freezing by closing the dampers to min when the ambient temperature is below 6ºC. The first kit controls the machine dampers. A second kit controls the machine dampers and also a remote damper fitted by the customer in the installation ductwork. Page 3 SD437360 ISSUE 33 THE CALOREX ‘SERIES 3 VARIHEAT’ RANGE. FEATURES :All versions have removable driptrays for easy cleaning. Control panel can be mounted remotely up to a maximum of 20 metre cable length. Models fitted with a fresh air box or a negative pressure box have motor driven louvres on the exhaust and fresh air dampers. Optional electrical resistance air heater boxes ranging from 6kW to 18kW. The power to each model in the range is fed in via din rail mounted terminal blocks located in the electric box of the unit. CONTROL PANEL. (All Models) Note AA Models do not have a water temperature controller, and do not include a time clock unless fitted with LPHW. The panel has the following features, 1. Relative Humidity Controller, with red light to indicate dehumidification demand. 2. Air Temperature Controller, with red light to indicate air heating demand. 3. Water Temperature Controller, with red light to indicator water heating demand. 4. Fresh Air Switch, with MAX, AUTO and MIN positions (for use with fresh air module or negative pressure box). 5. Economy Switch to select between water heating only or full function on AW versions. 6. On/Off Switch. NOTE with the switch in the OFF position the machine is still live and mains lamp and clock are energised. 7. Air/Water switch, can be set to give priority to either water heating or air heating. 8. Time clock to control “occupied/unoccupied” timings with battery ‘back up’ and manual override. 9. Indicator lights :Power on Fault Defrost Auto Dehumidification Air heating Water heating (if applicable). CONTROL PANEL (AW version shown, see section 3.0) ECONOMY SWITCH AIR/WATER SWITCH ºC % RH ºC MAX HUMIDITY AUTO AIR TEMP WATER TEMP = AUTO MIN = = AUTO Page 4 SD437360 ISSUE 33 1.1 OPERATION When the SERIES 3 VARIHEAT is connected to the mains supply via an isolator and the isolator is energised, the MAINS light on the side of the electric box will illuminate indicating mains ON and time clock will start to run. The time clock has a battery reserve fitted which when charged will run for 100 hours so that isolating the machine for short periods will not affect the time clock settings. The SERIES 3 VARIHEAT unit is switched on to normal operation by an ON (I)/OFF (O) switch on the control panel. When switched on the red indicator light will illuminate and digital controllers will light up. Note digital water controller will be the only controller to light up when in economy mode. Providing that the controls are set to the correct parameters; nominally 60% RH, 28ºC air temperature, 26ºC water temperature and fresh air switch set to AUTO, then the machine will operate automatically. The ‘unoccupied’ temperature is set on the digital air controller and will be switched at the time set on the time clock. As the unit operates, the indicator lights will show the state of the control conditions, ie dehumidification, heat to air and heat to water. Other indicator lights are :Yellow for Fault (high or low refrigerant trip or soft start fault if fitted). Yellow for Defrost Green to indicate automatic operation. See section 3.0 for control panel symbols. PARAMETER CONTROLLERS Each parameter, Relative Humidity, Water Temperature and Air Temperature is sensed within the machine and the signal is taken to the relevant digital controller. RH & Water Temperature controllers have two switching channels, also the Air Temperature controller for AA units without room heating: OUT1 which is set from the front panel, OUT2 which is factory pre-set. The Air Temperature digital controller for units with room heating has three switching channels, one of which is for setting OCCUPIED/UNOCCUPIED air temperature. Each channel has a switching differential which is also factory pre-set. None of the factory settings should be tampered with. When the re-settable channel is adjusted all other settings and differentials automatically follow at the correct relationship. Nominal set point values & diffs RH% Air temperature Water temperature = 60% = 28ºC = 26ºC diff 3% diff 0.5 ºC diff 0.2 ºC Please note: on AA machines with no fresh air box or RCU, in occupied mode dehumidification stops once the Air temperature is 2.5ºC above set point. TIME CLOCK The time clock setting determines the OCCUPIED/UNOCCUPIED periods and is set to match the operators requirements regarding opening and closing times for the pool and possible times where the pool is covered. The two settings are OCCUPIED or day time, and UNOCCUPIED or night time (covered). The most obvious action of this change is to lower the pool hall air temperature to a determined level to conserve air heating energy. This lowering of temperature is allowable because of the quiescent, and ideally covered, condition of the pool. = Pool water occupied (no pool cover) Pool water unoccupied (pool covered) O= Page 5 SD437360 ISSUE 33 2.0 INSTALLATION SITING, MACHINE LOCATION TOP OUTLET RANGE BOTTOM OUTLET RANGE AIR OFF ELEC BOX ASSY ELECTRICAL ACCESS PANEL WATER CONNECTIONS AIR ON ALTERNATIVE AIR OFF POSN'S AIR ON SERVICE PANEL SERVICE PANEL SERVICE PANEL SERVICE PANEL SERVICE PANEL AIR FILTER ACCESS PANEL ALTERNATIVE AIR OFF POSN'S ELEC BOX ASSY ELECTRICAL ACCESS PANEL SERVICE PANEL SERVICE PANEL (IF NOT DUCTED) AIR FILTER ACCESS PANEL ELECTRICAL ACCESS PANEL SERVICE PANEL (IF NOT DUCTED) WATER CONNECTIONS AIR OFF 800.00 SERVICE ACCESS AREA REQD FOR ALL SERVICE PANELS HORIZONTAL RANGE ALTERNATIVE AIR OFF POSN' ELECTRICAL ACCESS PANEL POOL WATER OUT 1" BSPM DRAIN 3/4" BSPM POOL WATER IN 1" BSPM AIR OFF BOILER WATER OUT 3/4" BSPM SERVICE PANEL BOILER WATER IN 3/4" BSPM SERVICE PANEL AIR FILTER ACCESS PANEL ELEC BOX ASSY AIR ON ALTERNATIVE AIR OFF POSN' Ensure duct work pressure drop does not exceed resistance given in data sheet. If unit is located in a plant room at pool hall air temperatures, any ambient air ducting must be heavily insulated. Recommend fresh air/exhaust spring return dampers to be fitted to ductwork for sub zero ambient applications in case of power failure. IMPORTANT - damper plate fitted on side of fan CAN be removed if ducting is fitted (all versions) but fan amps MUST be verified to be as per data sheet fan amps with dry coils, clean air filter and all panels fitted. Page 6 SD437360 ISSUE 33 2.0 INSTALLATION WITH OPTIONAL FEATURES BOTTOM OUTLET RANGE TOP OUTLET RANGE SPIGOT AIR OFF AIR FILTER ACCESS PANEL DAMPER OPTIONAL RESISTANCE HEATER IN THIS POSN' ONLY. POOL WATER OUT 1" BSPM DRAIN 3/4" BSPM OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS (225mm DIA) OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT (157mm DIA) SERVICE PANEL POOL WATER IN 1" BSPM BOILER WATER IN 3/4" BSPM BOILER WATER OUT 3/4" BSPM SERVICE PANEL SERVICE PANEL AIR ON OPTIONAL RESISTANCE HEATER IN THIS POSN' ONLY. SPIGOT POOL WATER OUT 1" BSPM DRAIN 3/4" BSPM POOL WATER IN 1" BSPM BOILER WATER OUT 3/4" BSPM BOILER WATER IN 3/4" BSPM SERVICE PANEL SERVICE PANEL AIR FILTER ACCESS PANEL DAMPER OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS (225mm DIA) OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT (157mm DIA) AIR ON SERVICE PANEL 800.00 AIR OFF SERVICE ACCESS AREA REQD FOR ALL SERVICE PANELS OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS (225mm DIA) OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT (157mm DIA) HORIZONTAL RANGE SPIGOT DAMPER AIR FILTER ACCESS PANEL POOL WATER OUT 1" BSPM DRAIN 3/4" BSPM POOL WATER IN 1" BSPM BOILER WATER OUT 3/4" BSPM AIR OFF SERVICE PANEL SERVICE PANEL BOILER WATER IN 3/4" BSPM SERVICE PANEL OPTIONAL RESISTANCE HEATER IN THIS POSN' ONLY. ELEC BOX ASSY AIR ON Ensure duct work pressure drop does not exceed resistance given in data sheet. If unit is located in a plant room at pool hall air temperatures, any ambient air ducting must be heavily insulated. Recommend fresh air/exhaust spring return dampers to be fitted to ductwork for sub zero ambient applications in case of power failure. IMPORTANT - damper plate fitted on side of fan CAN be removed if ducting is fitted (all versions) but fan amps MUST be verified to be as per data sheet fan amps with dry coils, clean air filter and all panels fitted. Page 7 SD437360 ISSUE 33 2.0 CONSOLE FIXING BOTTOM OUTLET RANGE TOP OUTLET RANGE AIR FILTER ACCESS PANEL ALTERNATIVE AIR OFF POSN'S SERVICE PANEL SERVICE PANEL SERVICE PANEL AIR FILTER ACCESS PANEL ELEC BOX ASSY ELECTRICAL ACCESS PANEL WATER CONNECTIONS AIR ON CONSOLE FIXING HOLES (3) ALTERNATIVE AIR OFF POSN'S AIR ON SERVICE PANEL SERVICE PANEL SERVICE PANEL ELECTRICAL ACCESS PANEL CONSOLE FIXING PANEL WITH 3 HOLES. SERVICE PANEL (IF NOT DUCTED) ELEC BOX ASSY AIR OFF SERVICE PANEL (IF NOT DUCTED) WATER CONNECTIONS AIR OFF 800.00 SERVICE ACCESS AREA REQD FOR ALL SERVICE PANELS ELECTRICAL ACCESS PANEL ALTERNATIVE AIR OFF POSN' ºC % RH ELEC BOX ASSY ºC MAX AUTO HUMIDITY AIR TEMP WATER TEMP = AUTO MIN = POOL WATER OUT 1" BSPM DRAIN 3/4" BSPM CONSOLE FIXING HOLES (3) BOILER WATER OUT 3/4" BSPM HORIZONTAL RANGE SERVICE PANEL BOILER WATER IN 3/4" BSPM AIR OFF SERVICE PANEL AIR FILTER ACCESS PANEL = POOL WATER IN 1" BSPM AUTO AIR ON ALTERNATIVE AIR OFF POSN' REMOVE SCREWS REPLACE SCREWS °C % RH °C MAX HUMIDITY AUTO MIN AIR TEMP WATER TEMP = AUTO 4 STAGE = = AUTO CONNECTING CABLE POSITION OF CONNECTOR POSITION OF CONNECTOR AFTER ROTATING PANEL CONNECTING CABLE NEW POSITION WITH PANEL ROTATED The Variheat 3 is designed with interchangable service panels. On delivery, a console fixing service panel is fixed in the position shown in the diagrams above. The console for the Variheat 3 will either be attached to the machine above the air filter access panel or located inside the Variheat 3 fan box. The console can be attached to the Variheat 3 as instructed below. 1. Fix the 3 self tapping screws provided into the 3 holes in the console fixing service panel. (Indicated by a label). Leave a small gap. 2. The console drops over the screws. Note: It is best to have the console panel close to the electric box, as once the console is fixed to the Variheat 3 the ribbon cable connector supplied with the Variheat 3 needs to be connected between the console and the electric box. The connector on the console is at the bottom. If the console is to sit on a shelf, the back panel on the console can be turned round. Remove the 6 fixings attaching the display to the back panel. Turn the panel round to that the connector points out of the back of the panel and replace the fixings. See sketch above. Page 8 SD437360 ISSUE 33 2.0 CONSOLE FIXING, VARIHEAT 3 WITH OPTIONAL FEATURES BOTTOM OUTLET RANGE TOP OUTLET RANGE SPIGOT AIR OFF DAMPER OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS (DIA 225mm) OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT (DIA 157mm) OPTIONAL RESISTANCE HEATER AIR FILTER ACCESS PANEL SERVICE PANEL POOL WATER OUT 1" BSPM DRAIN 3/4" BSPM CONSOLE FIXING PANEL WITH 3 HOLES. POOL WATER IN 1" BSPM SERVICE PANEL BOILER WATER OUT 3/4" BSPM BOILER WATER IN 3/4" BSPM SERVICE PANEL OPTIONAL RESISTANCE HEATER SPIGOT AIR ON OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS OR NEGATIVE PRESSURE BOX W ITH ONE SPIGOT DAMPER AIR FILTER ACCESS PANEL POOL WATER OUT 1" BSPM DRAIN 3/4" BSPM SERVICE PANEL POOL WATER IN 1" BSPM BOILER WATER IN 3/4" BSPM BOILER WATER OUT 3/4" BSPM SERVICE PANEL CONSOLE FIXING PANEL WITH 3 HOLES. AIR ON CONSOLE FIXING PANEL WITH 3 HOLES. SERVICE PANEL 800.00 AIR OFF SERVICE ACCESS AREA REQD FOR ALL SERVICE PANELS HORIZONTAL RANGE % RH ºC ºC MAX HUMIDITY AUT O AIR TEM P WATER TEM P = AUTO MIN = = UTO A SPIGOT ELEC BOX ASSY SERVICE PANEL AIR FILTER ACCESS PANEL POOL WATER OUT 1" BSPM DRAIN 3/4" BSPM RESISTANCE HEATER BOX POOL WATER IN 1" BSPM SERVICE PANEL BOILER WATER OUT 3/4" BSPM CONSOLE FIXING HOLES (3) SERVICE PANEL CONSOLE FIXING HOLES (3) BOILER WATER IN 3/4" BSPM AIR OFF DAMPER OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS (DIA 225mm) OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT (DIA 157mm) AIR ON The Variheat 3 is designed with interchangable service panels. On delivery, two console fixing service panels are fitted in the positions shown in the diagrams above. The console for the Variheat 3 will be inside the Variheat 3 fan box. Attach the console to the Variheat 3 console fixing panel selected as instructed below. 1. Fix the 3 self tapping screws provided into the 3 holes in the console fixing service panel. (Indicated by a label). Leave a small gap. 2. The console drops over the screws. Note: It is best to have the console panel close to the electric box, as once the console is fixed to the Variheat 3 the ribbon cable connector supplied with the Variheat 3 needs to be connected between the console and the electric box. The connector on the console is at the bottom. See the sketch on the previous page for instructions on how to rotate the console back panel. Page 9 SD437360 ISSUE 33 2.1 PLUMBING POOL WATER The Calorex ‘SERIES 3 VARIHEAT’ should be connected as shown in section 3.0. If an existing heater is being retained then the ‘VARIHEAT’ should be connected between the filter and the existing heater. Pool water connections on the machine are 1” BSPM stubs. The unit is supplied with 2 off each of the following PVC fittings - 1”BSPFx 1”M 1”F x 1½”M 1½” x 50mm F Suitable breakable couplings, isolation, and drain down valves should be installed in the pool water inlet/outlet pipes local to ‘VARIHEAT’ unit. The heat exchanger in the ‘VARIHEAT’ unit will, on small pools, take the full flow rate of the recirculation system. On larger pools a bypass or separate auxiliary pump may be necessary. This method can also be used to reduce energy consumption, by the installation of a two speed or auxiliary pump by-passing the main pump/filter to satisfy pool water heating and dehumidification without the need for the main pump to be running. When the pipework installation is complete the circulating pump should be switched on and the system checked for leaks. Also check the filter gauge to see that there is not excessive back pressure. CONDENSATE DRAIN The condensate driptray in the ‘VARIHEAT’ unit collects the water removed by the dehumidification process, It is therefore necessary to ensure that the’VARIHEAT’ unit is placed on a level plinth so that the condensate can run away and not overflow the edges of the driptray inside the machine. All ‘SERIES 3 VARIHEATS’ have a 3/4” BSPM threaded condensate drain connection. The drain pipe should run away with adequate fall to waste ie 1/2” per foot min. and must incorporate a ‘U’ trap & tun dish. BOILER PLUMBING The boiler connections on the machine are :3/4”BSPM on AW600/900 1” BSPM on AW1200/1500 for connecting the boiler water flow and return. Suitable breakable couplings, isolation, and drain down valves should be installed in the boiler water flow and return pipes local to the ‘VARIHEAT’ unit. Water and air LPHW circuits internal to Calorex Heat Pump should be bled for air pockets. (Bleed valves fitted to unit). Refer to the boiler manufacturers instructions before designing the pipework system. IMPORTANT GENERAL CONDITIONS 1. Do not route water pipes across service access panels or air inlet/outlets. 2. The water circuits to and from the ‘VARIHEAT’ unit should be capable of maintaining the specified water flow limits required by the machine. 3. All pipework must be adequately supported with allowance for expansion and contraction especially with regard to the plastic pipework. 4. It is recommended that when installing water systems the last connections to be made should be adjacent to the ‘VARIHEAT’ unit to avoid undue stresses on the unit connections. 5. All pool purifying devices and chemical injection systems must be fitted down stream of the ‘VARIHEAT’ unit with a non-return valve to prevent concentrated chemicals back feeding into the heat exchangers. 6. The practice of dosing chemicals direct into skimmer basket must not be allowed as this would result in concentrated corrosive liquids passing over vulnerable metal components. 7. Water quality must be maintained not only relating to solids, etc but for pH between 7.4 - 7.8, and if pool water is saline at a maximum concentration of 8mg/litre. 8. See Warranty Exclusions section 6.0 for total list of water quality limits. Page 10 SD437360 ISSUE 33 2.2 DETERMINING WATER FLOW Flow Meter Method (see pool water schematics) Ensure isolation valves ‘A’ and ‘B’ and bypass valve ‘C’ are fully open. Slowly close down bypass valve ‘C’ until correct flow rate is shown on the flow meter (see section 4.0). Remove handle and lock off valve ‘C’. Differential Pressure Method By simply installing two filter pressure indicating gauges, one on the inlet and one on the outlet of the heat pump, and a locking type gate bypass valve in the bypass line, the flow rate through the heat pump can be accurately determined by the difference in the readings of the gauges. This pressure drop is proportional to flow. Flow rate should be set at the maximum differential with a clean filter fitted, this differential pressure will drop as the filter becomes dirty. Provided the filter is cleaned before the minimum differential is reached then no problems should be encountered (standard system only) Setting up the differential When the installation is complete, the procedure for setting the flow rate through the heat pump using two gauges is as follows :1. With the heat pump switched off, ensure isolation valves ‘A’, ‘B’ and bypass valve ‘C’ are fully open. 2. Switch on water circulating pump. 3. Note the water system pressure on both gauges - they should read the same, but because of manufacturing tolerance they may read different. For example :- with a water system pressure of 5mhd the gauge on the inlet may read 5 and the outlet gauge 5.5 therefore there is a static error difference of 0.5mhd. 4. Gradually close the bypass valve ‘C’ until there is a difference in pressure between the two gauges that is equal to the required pressure drop (see section 4.0) observing any static error on the gauges before beginning this process. 5. Lock the bypass valve, or render it tamper proof when correct setting is achieved. 6. See section 4.0 for correct pool water pressure drop. Page 11 SD437360 ISSUE 33 POOL WATER SCHEMATIC (STANDARD) ENSURE POOL FILTRATION PUMP SELECTION ALLOWS FOR ALL SYSTEM RESISTANCE POOL SANITIZER OR CHEMICAL DOSING POSITION AFTER CALOREX AUX HEATER IF FITTED CALOREX FLOW SETTING PRESSURE GAUGES METHOD FLOW SETTING FLOW METER METHOD ISOLATING VALVE B ISOLATING VALVE A PUMP FILTER NON RETURN VALVE OR LOOP VALVE C BYPASS VALVE (LOCKING GATE VALVE TYPE) POOL WATER SCHEMATIC (FILTER DOSING) ENSURE POOL FILTRATION PUMP SELECTION ALLOWS FOR ALL SYSTEM RESISTANCE POOL AUX HEATER IF FITTED CALOREX FLOW SETTING FLOW METER METHOD FLOW SETTING PRESSURE GAUGES METHOD NON RETURN VALVE OR LOOP ISOLATING VALVE A NON RETURN VALVE OR LOOP ISOLATING VALVE B PUMP FILTER SANITIZER OR CHEMICAL DOSING POSITION BEFORE FILTER BYPASS VALVE C (LOCKING GATE VALVE TYPE) Page 12 SD437360 ISSUE 33 2.3 WATER CONNECTIONS (also see SECTION 2.1) AIR FILTER ACCESS PANEL POOL WATER OUT 1" BSPM DRAIN 3/4" BSPM POOL WATER IN 1" BSPM BOILER WATER OUT 3/4" BSPM AW600/900 1" BSPM ON AW1200/1500 BOILER WATER IN 3/4" BSPM AW600/900 1" BSPM ON AW1200/1500 SERVICE PANEL MAINS IN 25mm DIA VH3 DRAIN COPPER STUB CUSTOMERS "TUN DISH" VH3 UNIT DRAIN TO WASTE U TRAP BOILER WATER SCHEMATIC INTERNAL 3 WAY MOTORISED VALVE (DIVERTING) CONTROLLED BY VARIHEAT . SERIES 3 VARIHEAT CABINET FLOW BALANCE VALVE BOILER (FACTORY SET) PUMP RADIATORS IF FITTED FLOW METER Page 13 LPHW CONNECTIONS SD437360 ISSUE 33 2.4 ELECTROLYTIC CORROSION IN SWIMMING POOLS Electrolytic corrosion will occur when dissimilar metals that are in contact with each other create a potential difference between themselves. Sometimes separated by a conductive substance known as an electrolyte, the dissimilar metals will create a small voltage (potential difference) that allows the ions of one material to pass to the other. Just like a battery, ions will pass from the most positive material to the more negative material. Anything more than 0.3 volts can cause the most positive material to degrade. A swimming pool with its associated equipment can create this effect. The pool water being an ideal electrolyte and components of the filtration circuit, heating system, steps, lights etc providing the dissimilar metals needed to complete the circuit. Whilst these small voltages are rarely a safety threat, they can create premature failure through corrosion. Not dissimilar to corrosion through oxidation, electrolytic corrosion can cause complete failure of a metallic material in a very short period of time. In order to prevent this type of corrosion all metallic components in contact with swimming pool water should be bonded together using 10mm² bonding cable. This includes non-electrical items such as metal filters, pump strainer boxes, heat exchangers, steps and handrails. It is highly recommended that bonding be retrofitted to existing pools, which may not be protected by this system. Page 14 SD437360 ISSUE 33 2.5 ELECTRICAL INSTALLATION ELECTRICAL SAFETY It is important to ensure that all aspects of the installation comply with the latest I.E.E. Regulations. It is also important to ensure that any remote devices which terminate within the pool hall are of the type and voltage as specified in the latest I.E.E. Regulations. The machine should be installed in accordance with EMC2004/108/EC. PROTECTED SUPPLY Whilst not mandatory, Calorex recommend that an R.C.C.B. is always fitted or that the supply is to local electricity authority recommendations, and that all ducting is bonded in accordance with these regulations. The supply to the machine should incorporate fuses or motor rated circuit breakers (type GU, FAZC) to specified rating (see data sheet) H.R.C. fuses are recommended. An isolator must be fitted within clear view of the machine and not more than 2 metres away. The isolator must have a minimum of 3mm air gap when in the off position. INCONSISTENT ELECTRICAL SUPPLY. The following limits of operation must not be exceeded if Calorex machines are to be guaranteed either in performance or warranty terms :Voltage single phase 207V min, 253V max Voltage three phase 360V min, 440V max Frequency 47.5Hz min, 52.5Hz max. N.B The voltage must be measured at the heat pump mains terminals with all the fans/compressors running at the rated condition. Please note that AW1200/1500 three phase machines are fitted with a phase rotation relay and will not run if the phases are connected incorrectly or if the voltage is 15% less than 400V (340V) for a three phase 50Hz machine CORRECT CABLE SIZING The cable supplying electricity to a machine with a given load must increase in cross sectional area (CSA) as the length increases in order that the voltage drop within the cable does not exceed recommended limits. Cable sizing should be calculated by an approved electrician with due consideration to I.E.E. and local codes of practice. If resistance heaters are fitted an extra power supply will be required to the terminal blocks inside the heater box, see data sheet for supply amps and fuse size. AIR FILTER ACCESS PANEL DRAIN 3/4" BSPM ELEC BOX ASSY SERVICE PANEL FOR ACCESS TO MAINS TERMINAL BLOCKS, ETC SERVICE PANEL MAINS IN 25mm DIA 2off Page 15 SD437360 ISSUE 33 2.5.1 MAINS SUPPLY TERMINAL BLOCK LAYOUT SINGLE AND THREE PHASE (NO CONNECTION TO TERMINALS 4 AND 5 ON SINGLE PHASE UNITS) NO LINK WIRES NECESSARY IF TERM'S 6 TO 9 NOT IN USE N 52 53 54 55 56 RCU CONTROL UNIT ELECTRIC BOX TERMINAL RAIL RESISTANCE HEATER FAN STAT DAMPER MOTOR, LOCATED ON FRESH AIR BOX SOFT START LINK FAN CONT' FAN CYCLE FAN COMMON RCU (IF FITTED) OCC/UNOCCUPIED REMOTE ON/OFF. (SEE NOTE 'a' ) START REMOTE POOL PUMP VOLT FREE MACHINE ON VOLT FREE MAIN FAN RUN BOILER DEMAND 46 47 COMMON 43 44 45 RCU SOL VALVE A 32 33 34 35 36 COMMON AMBIENT STAT, OPENS MAX ON LOW TEMP J 6 7 8 9 10 11 12 13 14 15 16 RCU SOL VALVE B E N L 5 G H I MIN 1 2 3 4 (IF FITTED) RESISTANCE HEATER ASSY E N L1 L2 L3 OPTIONS IF THIS FACILITY IS USED TIME CLOCK (IF FITTED) MUST BE SET TO UNOCCUPIED REMOTE OCC/UNOCCUPIED SEE NOTE 1 SECTION 2.5.2 L POOL PUMP START SEE NOTE 2 SECTION 2.5.2 LOAD N L BOILER DEMAND SEE NOTE 3 SECTION 2.5.2 LOAD TERMINALS I & J VOLT FREE MAIN FAN RUN TERMINALS G & H VOLT FREE MACHINE ON OPTIONAL REMOTE SENSOR BOX TERMINALS IN REMOTE SENSOR BOX NOTE 'a' LINK THESE TERMINALS WHEN REMOTE NOT REQUIRED REMOVAL OF LINK WILL STOP FAN, COMPRESSOR & DIGITAL CONTROLLERS . 2 3 4 5 SWITCHED FUSE ISOLATOR SEE DATA SHEET FOR RATINGS P5 HUMIDITY SENSOR AIR PROBE P4 TERMINAL BLOCK UNDER FLANGE IN ELECTRIC BOX N L1 L 2 L 3 P6 P7 1 P3 SWITCHED FUSED ISOLATOR TO BE WITHIN SIGHT OF FRONT OF UNIT & NOT MORE THAN 2M AWAY N SEPARATE MAINS SUPPLY TERMINAL BLOCKS FOR RESISTANCE HEATER BOXES LAYOUT SINGLE AND THREE PHASE (NO CONNECTION TO TERMINALS L2 AND L3 ON SINGLE PHASE UNITS) EARTH STUD 1 E L1L2L3 3 5 1 3 5 2 4 6 MCB 2 4 6 CUSTOMER TERMINATIONS TO HEATER BOX SEE NOTE 4 SECTION 2.5.2 Page 16 SD437360 ISSUE 33 2.5.2 NOTES ON TERMINAL BLOCK CONNECTIONS NOTE 1 - Remote occupied/unoccupied These contacts (from terminals 10 & 11) are to enable the air temperature set back facility to be remotely overridden. Please note that in unoccupied mode on AW machines, water heating does not take place unless there is a demand for dehumidification. There is a 12 Vac output from these terminals and closing a remote switch will enable the unit to regain the normal operating air temperature for when the pool is in use. This can be done via a voltage free pool cover switch or some other form of voltage free switch. If this facility is used then the time clock (if fitted) on the control panel of the unit should be set to the ‘unoccupied’ (o) position. (See note on time clock and switch settings, section 3.2.1). If these terminals are fitted on versions without time clocks then they MUST BE LINKED. NOTE 2 - Pool pump start -AW only (see also section 3.2.2) These are voltage free contacts (from terminals 8 & 9) rated at 3(1) Amp at 230 Volts. If the pool water pump is to be run via an external time clock then these connections should go across the switching contacts of the external time clock to ensure that, if dehumidification demand occurs the pool water pump will start. The pool water pump will exceed the one amp inductive rated current of these contacts therefore a contactor or relay should be used to switch the load of the pump.The switching action of the external time clock should energise the contactor/relay coil. If the pool water pump is to be run continuously then these contacts can be ignored. NOTE 3 - Boiler demand -AA+LPHW & AW machines only These are voltage free contacts (from terminals 6 & 7) rated at 3(1) Amp at 230 Volts. If the low pressure hot water supply to the unit is to be governed by the Calorex unit then these contacts should be utilised to bring water to the unit via the boiler, motorised valve, boiler pump etc. Remember the maximum inductive load is one amp. This is dependant on how the low pressure hot water supply to the unit has been designed. If the supply of low pressure hot water to the unit is not dependant on a signal from the unit then these contacts can be ignored. NOTE 4 – SEPARATE SUPPLY FOR RESISTANCE HEATER BOX If resistance heaters are fitted then an extra power supply will be required to the terminal blocks inside the heater box. See section 4.0 for supply amps & fuse size. CONTROL PANEL 25 WAY CABLE CONNECTION Data signal between control panel and electric box is via a 25 way cable with ‘D’ connection (plug & socket) both ends. Page 17 SD437360 ISSUE 33 2.6 CIRCUIT DIAGRAMS ELECTRICAL CONTROL & POWER CIRCUIT ‘AW’ VERSION LINK FOR NORMAL RUN (BREAK TO STOP M/C) PHASE ROTATION L3 12 REMOTE ON/OFF FOR AW 1200 & 1500 13 ON/OFF SWITCH F1 2.5A SEE BELOW L2 ECONOMY SWITCH N/C 01 D1 CONTROL MCB F2 1A L1 P2 D7 11 WATER STAT' OUT2 OU T1 1 RISING 10 4 6 FALLING 5 2 R 1 D13 SWITCH H G D12 10 14 AUX 54 R1 8 6 R9 5 11 51 49 13 14 46 230v WATER LPHW VALVE 230v REVERSING VALVE 48 LPHW MICRO SWITCHES FAN CONTACTOR 4 THERMAL CUTOUTS 11 RESISTANCE HEATER ASSY CRANKCASE HEATER 7 R10 7 50 4 05 10 PUMP TO BOILER DEMAND TERMI NALS 7 R2 9 POOL 6 10 11 4 4 8 FITTED. 10 7 AIR LPHW VALVE 7 9 N/O AUX 53 11 58 TB:N DAMPER IF 04 13 N/O 7 COMP 12V AC D4 57 TB:L TO REMOTE 4 COMP 4 11 7 60m in TIMER 4 D CONTACTOR 240V 7 R8 D3 3 R13 SWITCH 10 D15 D14 9 A 28 21 AIR VOLT FREE M/C ON PRIORITY LAMP OUT2 FALLING 3 AI R/WATER 15 AIR HEATING 10 WATER HEATING TRANSFORMER RCU RCU 9 4 B 4 MAINS 8 11 7 FKR1 16 D6 P1 D 17 12V AC RELAY RCU (I F FITTED) 7 POWER LAMP R14 PROTECTION KIT R12 CONTROL 12v 62 FOR USE WITH FROST 6 03 P6 12v REM OTE DAMPER RELAY 9 SENSOR P7 61 N/C MCB (if fitted) FUSE 1A 02 PROBE 230v COMPRESSOR AUX CONTACTOR HUMIDITY D2 A2 A1 47 06 07 N N AW 1200 & 1500 ONLY PHASE ROTATION CONTROL MCB RELAY L3 L2 7 11 6 3 TO N POW ER CIRCUIT SINGLE PHASE TRANSFORMER 5 L1 L 1 CONTROL CIRCUIT BREAKER 2 A COMPRESSOR CONTACTOR Aux NC CONTROL CIR CUIT BREAKER 2A (4A WHEN FRESH AIR OPTI ON INSTALLED) RCU CIRCUIT NOTES BREAKER 5A COMPR ESSOR FAN CIRCUIT BR EAKER CIRCUIT BREAKER 'R' LETTER RELAY'S ARE 12v TO RCU RELAY 'RE' LETTER RELAY'S ARE 230v 46 CONTROL CIRCUIT 'P' LETTERS ARE CONNECTOR BLOCK PIN NUMBERS N 15 = DIN RAIL MOUNTED TERMINAL BLOCK NUMBERS D25 = 25 W AY ' D' PLUG PIN NUMBERS FAN 1 1 3 5 13 A1 2 4 6 14 A2 A1 3 5 4 6 COMP CONTACTOR CONTACTOR 2 IF REMOTE OCC/UNOCC FEATURE USED 2 a) FORCE TIME CLOCK TO 'UNOCCUPIED' A2 24 TIMER 17 TO RE4(A) 23 c) 10/11 N/C = ' OCCUPIED' TO TB 38 b) 10/11 N/O = 'UNOCCUPIED 19 R UN W(C) V(S) CAPACITOR N FAN MOTOR 1 2 3 N/C N/C N/C 4 VH3 MK II AW CIRCUIT D459850 ISS 24 5 N/O 6 N/O 7 N/O 8 COM MODEL U(R) COMPRESSOR FAN MCB 1 PHASE 'F' COMP MCB NON 'F' DEVICE VALUE AA/AW600AVHX(F) 4.6A 2.2A AA/AW900AVHX(F) 5.9A 3.2A 17.9A AA/AW1200AVHX(F) 9A 3.6A 23.9A 11.5A 9 COM 10 RES' HEATER CONTROL IF FITTED L 18 COM 11 COIL STANDARD RELAY FORMAT Page 18 SD437360 ISSUE 33 2.6 ELEC CONTROL & POWER CIRCUIT ‘AW’ VERSION CONTINUED REMOTE LINK IF REMOTE CONTROL FITTED OCC/UNOCC NOT LINKED FOR NORMAL RUN SEE NOTE 2 01 10 11 + 0-10VDC D11 P5 D10 P6 P7 02 SUPPLY 12V 03 GRND 0V - PROBE TIME CLOCK OUT2 21 5 3 24 7 <3> 8 3 OUT3 22 FALLING 20 <PALADIN> P4 D9 <2> M OUT1 19 FALLING 1 17 1 4 18 10- RISING R12 11+ HUMIDITY STAT' 4 2 RISING 23 9 OUT2 < 1> OCCUPIED AIR STAT' 14 TERMI NALS VARY WI TH MANUF ACTURER RCU OUT1 N/O DEHUM LAMP 1 RISING 5 2 6 R2 N/O 3 4 MIN MAX 1 10 R4 AUTO D 18 7 HP SWITCH L H A B C 30 10 10 11 11 3 POSN CHANGEOVER SWITCH CENTRE OFF DAMPER FRESH AIR BOX 9 R4 R12 D21 D24 6 (RCU) H CYCLE FAN COM' 1 L SOFT START 31 1 FAULT LAMP 5 D23 R13 4 LP SWITCH 7 11 R4 FAN 33 230v 34 4 8 7 RE1 R5 D16 R4 32 29 C D15 10 FAN CONT' 6 D20 D5 04 9 4 UNOCCUPIED OR IF FITTED RE3 LINK RE3 N/C 35 7 10 36 4 1 9 55 37 R3 11 1 3 05 11 7 41 40 6 DF 10 R6 LPHW FROST PROTECTION STAT OPENS ON LOW TEM P (IF FITTED) 9 LINK IF STAT 7 11 NOT FITTED MAX D22 MIN FAN MOTOR 43 4 44 SOLENOID VALVE 4 3 42 38 56 39 RE4 45 L Lo N 1 4 TIMER COMPRESSOR 2(4) 1(2) P(1) STAT 6 min A2 A1 10 B 4 A 7 9 A A2 7 8 R12 4 RE2 230V 1 FAN CONTACTOR D25 2 DEFROST 3 DEFROST LAMP AUTO LAMP RESISTANCE HEATER FAN STAT D8 P3 13 AIR SENSOR R/H NORTRONICS 6 3 4 1 5 B 2 A1 J I R7 T.B. DAMPER EARTH FAN MOTOR 06 7 VOLT FREE 11 CAP MAIN FAN RUNNING FRESH AIR BOX (IF FITTED) 07 N 54 52 53 A B RCU SOL' VALVES POWER CIRCUIT 3 PHASE WITH 3 PHASE FAN POWER CIRCUIT 3 PHASE WITH SINGLE PHASE FAN L3 L3 L2 L2 L1 L1 1 CONTROL CIRCUIT BR EAKER 2A (4A WHEN FRESH AIR OPTION INSTAL LED) CIRCUIT CIRCUIT MOT OR BREAKER BREAKER STARTER 2 4 6 7A (MCB) TO RC U RELAY 3 5 1 3 5 2 4 6 MAIN FAN COMPRESSOR MOTOR CIRCUIT BREAKER 2 TO RCU RELA Y 46 CONTRO L CIRCUIT 1 4 STARTER 6 CONTRO L (MCB) 46 C IRCUIT N N FAN 1 3 5 13 COMP 1 A1 A1 3 5 CONTACTOR CONTACTOR CONTACTOR 2 4 6 14 A2 2 4 3 5 13 A1 1 A1 3 5 2 4 6 14 A2 2 4 6 N FAN MOTOR TO RE4(A) TO TB 38 IF FITTED L RES' HEATER CONTRO L 24 TIMER 23 17 18 24 25 19 S C R FAN MOTOR A2 17 MODEL MODEL D EVICE VALUE 'F' 4.6A NON 'F' 2.2A AA/AW900BVHX(F) 5.9A 3.2A 6.8A AA/AW1200BVHX(F) 9A 3.6A 10.5A 18 19 4.7A AA/AW1500BVHX(F) Page 19 18 19 V(S) U(R) W(C) S C R COMPRESSOR SANYO COMPRESSOR COMP MCB AA/AW600BVHX(F) 17 TIMER COM PRESSOR FAN MCB 1 PHASE CONTACTOR 6 A2 23 COMP 1 FAN TO TB 38 5A CONTROL CIR CUIT BREAKER 2A (4A WHEN FRESH AIR OPTION INSTALLED) RCU COMPRESSO R TO RE4(A) BREAKER 5 IF FITTED CIRCUIT 3 MAIN FAN RES' HEATER CONTROL RCU FAN MCB COMPRESSOR ONLY COMP MCB 'F' NON 'F' 3.5A 2.5A DEVICE VALUE 14.4A SD437360 ISSUE 33 ELECTRICAL CONTROL CIRCUIT ‘AA+LPHW’ VERSION See pages AW circuit for power circuits LINK FOR NORMAL RUN (BREAK TO STOP M/C) PHASE ROTATION REMOTE ON/OFF 12 13 ON/OFF SWITCH FOR AW1200 & 1500 L3 F1 2.5A SEE BELOW 01 D1 L2 CONTROL MCB F2 1A D2 L1 02 SENSOR D8 P3 N/C 12v P4 D9 CONTROL 12v POW ER LAMP 112 R14 7 4 FOR USE WITH FROST PROTECTION KIT 13 11 10 OUT2 14 AIR STAT' OUT1 21 FALLING 20 24 3 OUT3 22 19 F ALLING D17 1 05 17 RISING 23 18 (IF FI TTED) H G R12 FKR1 6 7 B D15 D14 VOLT FREE 12V AC RELAY 111 04 PROBE P6 REMOTE DA MPER RELAY 9 RCU P7 AIR HEATING RCU MCB (IF FITTED) FUSE 1A AUX CONTACTOR COMPRESSOR HUMIDITY 03 06 7 M/C ON R4 240V 4 16 RCU MAINS 4 A LAMP 28 D4 12V AC 15 10 7 10 7 11 07 6 7 LPHW MICRO SWI TCHES (IF FITTED) 13 14 D A2 A1 08 46 230V TO BOILER DEMAND TERMINALS AIR LPHW VALVE FITTED. 4 FAN CONTAC TOR DAMPER IF 4 THE RMAL CUTOUTS TO REMOTE 11 R2 RESISTANCE HEATER ASSY TB:N R1 CONTACTO R 58 TB:L CRANKCASE HEATER 57 TRANSFORMER D3 47 09 N N NOTES 'R' LETTER RELAY'S ARE 12V 'RE' LETTER RELAY'S ARE 230V 'P' LETTERS ARE CONNECTOR BLOCK PIN NUMBERS 15 = DIN RAIL MOUNTED TERMINAL BLOCK NUMBERS D25 = 25 WAY 'D' PLUG PIN NUMBERS D = DELAY TIMER 2 IF REMOTE OCC/UNOCC FEATURE USED a) FORCE TIME CLOCK TO 'UNOCCUPIED' b) 10/11 N/O = 'UNOCCUPIED c) 10/11 N/C = 'OCCUPIED' VH3 MK II AA + LPHW CONTROL CIRCUIT D459851 ISS 21 Page 20 SD437360 ISSUE 33 2.6 ELEC CONTROL CIRCUIT ‘AA+LPHW’ CONTINUED REMOTE LINK IF REMOTE CONTROL FITTED OCC/UNOCC NOT LINKED FOR NORMAL RUN SEE NOTE 2 01 10 11 02 D11 P5 D10 P6 + 0-10VDC P7 03 SUPPLY 12V GRND 0V 04 TIME CLOCK NORTRONICS TERMINALS VARY WITH MANUFACTURER <PALADIN> <1> 9 2 RISING OCCUPIED RISING 18 10- HUMIDITY STAT' 4 OUT1 5 2 6 3 HP SWITCH MIN AUTO MAX R4 C 10 R4 D24 R12 6 (RCU) H SOFT START 31 IF FITTED OR LINK N/C 35 7 10 R6 7 11 LINK IF STAT 55 37 3 7 2 DEFROST STAT L Lo N FAN MOTOR 4 10 43 SOLENOID VALVE 4 4 3 42 TIMER 56 39 RE4 COMPRESSOR 45 1 38 D D22 MAX MIN 1 41 40 6 NOT FITTED 2(4) 1(2) P(1) A2 A 1 B 4 A 7 A1 J 9 A A2 7 8 6 3 4 1 5 B 2 I 44 7 R7 11 T .B. DAMPER MOTOR 9 10 DEFROST LAMP 4 08 LPHW FROST PROTECTION STAT OPENS ON LOW TEMP (IF FITTED) 1 DF 1 9 36 4 R3 11 3 FAN COM' 1 RE3 07 D25 4 LP SWITCH RE3 11 AUTO LAMP CYCLE L 1 3 POSN CHANGEOVER SWITCH CENTRE OFF DAMPER FRESH AIR BOX 9 FAULT LAMP 11 FAN 33 34 7 D21 7 230v L 30 5 A RE1 H AIR HEATING 11 D23 32 C B 10 FAN CONT' 6 29 OPTIONS OVER 1 4 R5 8 R11 NO OPTIONS N/O 1 7 D16 R4 R2 R11 N/C D20 D5 10 AIR HEATING ONLY 9 4 ONLY RISING D18 11 RCU N/O AIR HEATING 1 NO OPTIONS UNOCCUPIED 06 10 R12 11+ RESISTANCE HEATER FAN ST AT 8 OUT2 <2> 1 7 R12 <3> 3 05 4 DEHUM LAMP RE2 230V 5 M - AIR SENSOR R/H FAN CONTACTOR PROBE FAN EART H CAP FRESH AIR BOX (IF FITTED) 09 N 54 52 53 A B RCU SOL' VALVES See AW circuits for power circuits Page 21 SD437360 ISSUE 33 ELECTRICAL CONTROL CIRCUIT ‘AA’ VERSION See pages AW circuit for power circuits LINK FOR NORMAL RUN (BREAK TO STOP M/C) PHASE ROTATION REMOTE ON/OFF FOR AW1200 & 1500 L3 12 ON/OFF SWITCH 13 F1 2.5A SEE BELOW 1 D1 L2 CONTROL MCB F2 1A L1 D2 111 P7 SENSOR P6 D8 P3 12v 10 12v 112 R4 11 P4 D9 CONTROL POWER LAMP 8 AIR HEATING N/C OPTIONS ONLY AUX CONTACTOR RCU MCB (IF FITTED) COMPRESSOR HUMIDITY 2 PROBE D17 R14 7 11 9 10 11 AIR STAT' OUT1 OUT2 1 FALLING 2 4 RISING 3 6 5 4 R12 12V AC 16 MAINS RCU 8 R4 M/C ON 28 12V AC 15 D4 10 7 11 4 D3 TRANSFORMER 3 D16 G VOLT FREE LAMP CRANKCASE HEATER D15 D14 H 240V 6 10 10 R1 R2 11 R11 NO OPTIONS RCU RELAY 9 5 10 10 11 11 R12 (RCU) 4 5 N N NOTES 'R' LETTER RELAY'S ARE 12V 'RE' LETTER RELAY'S ARE 230V 'P' LETTERS ARE CONNECTOR BLOCK PIN NUMBERS 15 = DIN RAIL MOUNTED TERMINAL BLOCK NUMBERS D25 = 25 WAY 'D' PLUG PIN NUMBERS D = DELAY TIMER 2 IF REMOTE OCC/UNOCC FEATURE USED a) FORCE TIME CLOCK TO 'UNOCCUPIED' b) 10/11 N/O = 'UNOCCUPIED c) 10/11 N/C = 'OCCUPIED' VH3 MK11 'AA' CONTROL CIRCUIT D459852 iss 20 Page 22 SD437360 ISSUE 33 2.6 ELEC CONTROL CIRCUIT ‘AA’ CONTINUED LINK IF RE MOTE CONTROL FITTED 1 + 0-10VDC D11 P5 D10 P6 P7 2 S UPPLY 12V GRND 0V - AIR S ENSOR R/H TERMINALS VARY WITH MANUFACTURER 4 RISING 5 10- OUT1 R12 RCU N/O 1 9 4 RISING 2 6 7 DEHUM LAMP 11+ R2 N/O NO OPTIONS R11 N/C 3 D20 1 7 OPTIONS ONLY MIN R5 AUTO MAX 1 10 4 H L C 30 7 D21 D23 D24 R12 6 3 1 4 IF FITT ED OR LINK RE3 N/C 35 7 10 37 3 41 40 STAT 11 DF 1 SOLENOID 4 10 43 D22 44 R7 11 EARTH CAP VALVE 4 3 42 38 D TIMER 39 RE4 A2 A1 FAN CONTACTOR MOTOR 6 2 DEFROST LAMP 7 T.B. FAN 7 DEFROST 7 DAMPER 1 9 10 45 MOTOR 36 4 R3 MAX L Lo N 1 SOFT START 31 R6 9 MIN FAN COM' LP SW ITCH 11 D25 CYCLE 34 4 L 4 AUTO LAMP FAN 33 230v COMPRESSOR (RCU) 7 RE1 RE3 FAULT LAMP R4 H 1 3 POSN CHANGEOVER SWITCH CENTRE OFF DAMPER FRESH AIR BOX 9 FAN A HP SW ITCH B 11 32 C D18 3 FAN CONT' 6 29 A2 A1 B 4 A 7 J 9 A 6 7 4 3 B 8 1 5 R12 (RCU) 9 HUMIDITY STAT' RE 2 230V 8 OUT2 2 I FRESH AIR BOX (IF FITTED) 5 N 54 52 53 A B RCU SOL' V ALVES See AW circuits for power circuits Page 23 SD437360 ISSUE 33 2.7 REGULAR PLANNED MAINTENANCE Operations to be carried out during a regular planned maintenance visit are as follows: 1. 2. Replace all belts where fitted. Clean or replace filters as applicable. (This action may be required more frequently than regular servicing. 3. Check operation and condition of all fans and compressors. 4. Check capacitor tolerances (where fitted). 5. Check condition of all heat exchangers/evaporators. 6. Check refrigeration system parameters. 7. Check operation of control valves. 8. Check for water leaks. 9. Check drip trays and internal drain lines for blockages and clear. 10. Check operation of controls and calibrate as necessary. 11. Check operation of interlocks in use. 12. Final check on overall operation of unit. 13. Indicate on report any faults found or causes for concern. Frequencies recommended: Light to medium use Heavy use Page 24 2 visits per year. 4 visits per year. SD437360 ISSUE 33 3.0 CONTROLS ECONOMY SWITCH STANDARD CONTROL PANEL MODULE (12V) AIR/WATER SWITCH see note a below ºC % RH ºC see note ‘a’ below MAX HUMIDITY AUTO AIR TEMP WATER TEMP = AUTO MIN = = AUTO Power on Power off Power symbol Fresh air flow Switch (for fresh air/negative pressure box options only)- - in AUTO position auto indicator light will be on. - in MAX position dampers fully open, light off. - in MIN position dampers closed, light off. ºC ºC Fault light Check that the pool hall air and water flow through the unit are within specified limits. Check M.C.B.’s & pressure switches see note b (also soft start overload if fitted) and push all to reset. Call for a service check if fault light stays on. Defrost light Unit is temporarily defrosting evaporator machine will automatically reset. Dehumidification light Indicates that there is a demand for the unit to dehumidify. Air heating light Indicates that there is a demand for the unit to heat the pool hall air. Water heating light Indicates that there is a demand for the unit to heat the pool water. Pool hall symbol Manual override symbol = O = Pool water occupied (no pool cover) Pool water unoccupied symbol (pool covered) Economy Switch Air to Water Switch (AW versions only). Switches between full function, i.e. dehumidification/air & water heating to water heating only. Note that in economy mode there is a 60 minute time delay before water heating commences. (AW versions only). Can be set to give priority to either water heating or air heating. Note ‘a’ Water temperature display and Economy switch not fitted on ‘AA’ or ‘AA+LPHW’ versions, time clock not fitted on ‘AA’ version. Note ‘b’ High & low pressure switches are mounted on a cross bracket fitted inside the fridge box assemblies. Push the red button on each switch to reset. Page 25 SD437360 ISSUE 33 OPTIONAL REMOTE CONTROL PANEL MODULE (12V) AIR/WATER SWITCH ECONOMY SWITCH See note a section 3.0 HUMIDITY MAX AUTO MIN % RH AIR TEMP = AUTO ºC = = WATER TEMP AUTO ºC AUTO Note - water sensor lead can be extended up to 20 metres with 0,5mm² cable. Also on sensor lead terminal block ( located in electric box assy) terminals P5 & P7 must be linked for this control panel to operate. OPTIONAL REMOTE SENSOR BOX Disconnect wires to sensors at electric box terminals & run leads to sensor box & connect as shown use 0,5mm² cable up to 20 metres. SENSOR PLUG AND TERMINAL BLOCK P7 P6 P5 P4 P3 P2 P1 DISCONNECT LEADS THIS SIDE & REPLACE WITH REMOTE SENSOR LEADS B LB GR V 0,5 PU W 0,5 SENSOR BOX TERM 5 SENSOR BOX TERM 4 SENSOR BOX TERM 3 SENSOR BOX TERM 2 SENSOR BOX TERM 1 SENSOR/PROBE TB RE1 RE2 RE3 R1 R2 R3 R4 HUMIDITY STAT 4 TIMER 3 DELAY 2 TIMER 1 DELAY P7 P6 P5 P4 P3 5 R8 AIR STAT R9 R10 ELECTRIC BOX Page 26 SD437360 ISSUE 33 3.1 COMMISSIONING CHECKLIST a. Is the building finished in accordance with the original plans and specification. b. Is the plenum chamber and all ductwork insulated, special attention should be made to the insulation of the exhaust air ducting and fresh air inlet ducting to prevent condensation problems. c. Are there any significant draughts in the pool hall or plant room (plenum installation) through poorly fitting doors, windows, pipe ducts, etc. This will let in unwanted ambient air raising the heating duty required. d. Is fresh air suction and exhaust air discharge ducting (if fitted) perfectly sealed from plant room. NOTE: (c) and (d) above should be checked by measuring plant room and pool hall air temperatures.If the plant room is acting as a plenum chamber both temperatures should correspond. If the plant room temperature is lower then ambient air is leaking in, this leak should be located and rectified. e. Are the fresh air inlet and exhaust air outlets free from obstructions ie, undersize grilles, objects in the path of exhaust air deflecting it back to the fresh air inlet, etc. f. Is ‘occupied / unoccupied’ set correctly, (set with air thermostat) see section 3.2.3. g. Is the time clock set correctly. h. Is start up (‘fresh air flow’ switch to ‘min’) feature required and if so is customer aware of when to switch machine back to ‘Auto’. i. Has the Calorex Heat Pump been bled for air pockets. (Bleed valves fitted to unit as standard). j. Any sign of abnormal operation such as water dripping should be reported immediately to an installer or Calorex. k. Is airflow sufficient through machine? Remove fan damper plates and check fan amps. l. Check belts and filters are fitted correctly. 3.2.1 TIME CLOCK SETTINGS The time clock is a quartz 24 hour clock with 100 hours battery reserve used to control the automatic operation or the SERIES 3 VARIHEAT unit per 24 hour time cycles. SETTING ACTUAL TIME Turn the large clock hand clockwise until the correct time of day is set, ensuring that the correct half of the day is chosen (24 hour clock). 12 13 14 1 5 16 SEGMENTS 11 17 10 18 9 19 8 20 21 7 AUTOMATIC AND MANUAL SETTING LEVER 22 6 5 23 24 1 2 3 4 0 A FIG 1. SETTING FOR AUTOMATIC OCCUPIED/UNOCCUPIED OPERATION WITH TIME CLOCK To set for automatic time clock control of occupied/unoccupied, slide the lever to ‘A’. Each yellow segment represents a 15 minute time period. Extend outward the segment s for a period of time that the pool is occupied (i.e. used or uncovered) per day. If the unoccupied period is more than 20 hours per day, extend one segment at 9:00 or other suitable time that does not coincide with the main occupied period*. Page 27 SD437360 ISSUE 33 SETTING FOR AUTOMATIC OCCUPIED/UNOCCUPIED OPERATION WITH REMOTE INTERFACE To set for remote control of occupied/unoccupied, slide lever to ‘O’. See section 2.4, Note 1 for more information on remote interface. If the unoccupied period is more than 20 hours per day, extend one segment at 9:00 or other suitable time that does not coincide with the main occupied period.* Ensure all other segments are pushed inwards and slide lever to ‘A’. SETTING FOR MANUAL OCCUPIED/UNOCCUPIED OPERATION To set for manual occupied period (or override automatic unoccupied period) slide the lever to ‘I’ for ‘occupied’. If the unoccupied period is more than 20 hour per day, to set for a manual unoccupied period slide the lever to ‘O’ for ‘unoccupied’; extend outwards one segmentat 9:00 or other suitable time that does not coincide with the main occupied period* and ensure all other segments are pushed inwards. *In unoccupied mode, the pool water is not heated unless a demand for dehumidification occurs during this period. If the unoccupied is more than 20 hours per day, it is recommended to allow a brief occupied period to allow the water temperature to be sampled and maintained if necessary. 3.2.2 WIRING TO EXTERNAL SWIMMING POOL PUMP/FILTER TIME CLOCK L 9 8 SERIES 3 VARIHEAT. EXTERNAL COMPONENTS TO BE WIRED TO TERMINAL BLOCK LOCATED INSIDE MACHINE ELECTRIC BOX. SEE SECTION 2.4 CUSTOMERS EXTERNAL PUMP/FILTER TIME CLOCK POOL PUMP STARTER N Page 28 SD437360 ISSUE 33 3.2.3 POOL & AIR TEMPERATURE AND HUMIDITY CONTROLS POOL WATER TEMPERATURE & HUMIDITY DIGITAL CONTROLLERS AND AIR DIGITAL CONTROLLER ON AA MACHINE WITHOUT AIR HEATING To Program the Set Point. Press down P, SP1 and Set Point value will be displayed alternately. Press the or key to change the value of SP1. Once the desired value is displayed press P to memorise the value. The display will revert to the present reading. NOTE: If anything else shows on the display leave alone for 1 minute until the display returns to normal. AIR TEMPERATURE DIGITAL CONTROLLER AW AND AA MACHINES WITH AIR HEATING The digital controller for controlling air temperature can be changed as follows:- To program the set point, press P button once and release it. SP1 (set point) and set point value e.g. 28 will be displayed alternately. Press P again AL1 (-4.5) will show. This is the difference between the set point and AL1 plus a constant 0.5 e.g. 28 - 4.5 + 0.5 = 24ºC (unoccupied) SP1 and AL1 can be changed in the same way as described for humidity and air. NOTE: AL1 can only be set -1 to -10 below SP1 value. If the reading on the digital controller is not the same as the actual pool hall temperature, water temperature or relative humidity it may be necessary to program an offset into the digital controller. See technical manual. FRESH AIR BOX AUTO MAX MIN NOTE Opens dampers and switches on fan when demand for dehumidification (OUT 2) and/or high temperature OUT 3 (OUT 2 on AA version without time clock). Machine must be in occupied mode to close Relay 4 and to bring on fan and open damper motor. Opens dampers and brings on fresh air fan to provide full fresh air at all times, even in unoccupied mode. Turns off fresh air fan and closes dampers to minimum position. On machines with LPHW, if the optional frost protection stat is fitted, the operation of the dampers will be inhibited when the ambient temperature is below 6ºC. NEGATIVE PRESSURE BOX AUTO MAX MIN NOTE Opens dampers and switches on fan when demand for dehumidification (OUT 2) and/or high temperature OUT 3 (OUT 2 on AA version without time clock). Machine must be in occupied mode to close Relay 4 and to bring on fan and open damper motor. Opens dampers to exhaust air from pool hall at all times, even in unoccupied mode. Turns off fresh air fan and closes dampers to minimum position. On machines with LPHW, if the optional frost protection stat is fitted, the operation of the dampers will be inhibited when the ambient temperature is below 6ºC. Page 29 SD437360 ISSUE 33 4.0 DATA SHEET SERIES 3 VARIHEAT MODEL:VIA HEA T PUMP (30º C/60% rh) DEHUMIDIFICATION TOTAL @ 18º C dew point (summer if fresh air option fitted) DUTY TOTAL @ 7ºC dew point (w inter if fresh air option fitted) VIA HEA T PUMP (MODE A):VIA HEA T PUMP (MODE B):HEAT TO AIR VIA SINGLE LPHW @ 80ºC :TOTAL :- (MODE B) VIA DOUBLE LPHW @ 80º C :HEAT REQ' FOR FRESH AIR @ -5 º C(IF OPTION *FITTED) BUILDING HEAT AV AILABLE FOR FABRIC LOSSES @ -5º C LOSS (FRESH AIR OPTION NOT FITTED) VIA HEA T PUMP (MODE A):VIA HEA T PUMP (MODE B):HEAT TO POOL VIA LPHW @ 80ºC :WATER (AW TOTAL :VERSIONS) Flow Rate Pool Water ± 10% Pressure Drop @ Rated Flow Max w orking pressure RECOMMENDED BOILER CA PACITY RECOMMENDED BOILER CA PACITY RECOMMENDED FLOW RATE SINGLE CAPACITY LPHW BOILER CAPACITY FLOW RATE DOUBLE CAPACITY LPHW (AW VERSIONS) Pressure Drop @ Rated Flow SINGLE CAPACITY LPHW Pressure Drop @ Rated Flow DOUBLE CAPA CITY LPHW RECOMMENDED BOILER CA PACITY RECOMMENDED BOILER CA PACITY RECOMMENDED FLOW RATE SINGLE CAPACITY LPHW BOILER CAPACITY FLOW RATE DOUBLE CAPACITY LPHW (AA+LPHW) Pressure Drop @ Rated Flow SINGLE CAPACITY LPHW Pressure Drop @ Rated Flow DOUBLE CA PACITY LPHW Max system w orking pressure TOTAL POWER CONSUMED (nominal) :- 'F' & NON 'F' MIN' SUPPLY CAPACITY (Max F.L.A.) 'F' & NON 'F' 1 ph N:ELECTRICAL MIN' SUPPLY CAPACITY (Max F.L.A.) 'F' & NON 'F' 3 ph N:MA X' SUPPLY FUSE 1 ph N:- 'F' & NON 'F' MA X' SUPPLY FUSE 3 ph N:- 'F' & NON 'F' AIR FLOW (anemometer @ air on filter, w et evaporator) MA X EXTERNA L STATIC PRESSURE:- 'F' & NON 'F' SINGLE LPHW MA X EXTERNA L STATIC PRESSURE:- 'F' & NON 'F' DOUBLE LPHW DESIGN CONDITION AMPS:- MAIN FAN 1 ph N :- 'F' & NON 'F' 3 ph N :- 'F' & NON 'F' FLA:- 1 ph N:- 'F' & NON 'F' FLA:- 3 ph N:- 'F' & NON 'F' NOMINAL POWER CONSUMED:LRA:- 1 ph N:RLA:- 1 ph N:COMPRESSOR SOFT STA RT AMPS 1 ph N:LRA:- 3 ph N:RLA:- 3 ph N:SOFT STA RT AMPS 3 ph N:Herme tic Sys tem GA S CHARGE (R407c) AA & AW GENERAL DATA LPHW battery volume WEIGHT approx' (A W un-packed no options):OPTIONAL FRESH AIR FLOW:AIR FEATURE MA X EXTERNA L STATIC PRESSURE NOMINAL POWER OPTIONAL MINIMUM SUPPLY 1 ph N :RESISTANCE MINIMUM SUPPLY 3 ph N :- HEATER MODULE MA X' SUPPLY FUSE (MCB) 1 ph N :MA X' SUPPLY FUSE (MCB) 3 ph N :- Units AA/AW600 litres/hr 4.6 litres/hr 5·2 litres/hr 6·5 kW 0 kW 5.1 kW 11 kW 14 kW 18,7 kW 1.7 kW kW 5.5 kW 0 kW 18 kW 23.5 l/min 30 m/hd 3.5 bar 3·5 kW 29 Btu's/hr 100000 l/min 25 l/min 32 m/hd 6.3 m/hd 6.3 kW 11 Btu's/hr 37500 l/min 10 l/min 14 m/hd 1.6 m/hd 1.6 bar 6 kW 2.46 / 1.97 amps 15.3 / 12 amps 9.2 / 6 amps 25 / 20 amps 16 / 10 m³/hr 2000 ±10% mm Wg 23 / 5 mm Wg 22 / 4 18.4 30 34.7 7.4 0 30 37.4 32 3.5 3·5 44 150000 32 44 6.3 6.3 13.5 46000 10 24 1.6 4.1 6 3·3 / 2.97 20 / 18 12 / 8.8 30 / 25 16 / 12 2500 ±10% 23 / 8 21.8 / 6.8 10 0 30 40 33 3·5 3·5 54 184250 42 64 6.3 4.5 24 81900 22 44 1.6 4.2 6 4 / 3.82 29 / 23.5 17.8 / 13.3 42 / 35 25 / 20 3500 ±10% 18 / 5 16 / 3 12.5 0 40 52.5 40 3·5 3·5 68 232000 52 74 6.3 4.9 28 95500 22 44 1.6 4.2 6 5.6 / 5.16 N/A 13 / 12 N/A 20 / 16 4300 ±10% 24 / 12 21.5 / 9.5 amps amps amps amps kW amps amps amps amps amps amps 3.75 / 1.9 N/A 5.2 / 2.2 N/A 1.7 55 8·4 26 30 3·2 14 4.5 / 2.7 N/A 5.9 / 3.2 N/A 2·3 76 12.4 31 42 4·7 16 9.3 / 4.5 N/A 9.3 / 4.5 N/A 3.5 100 16.6 34 48 7.3 17 N/A 3.3 / 2.3 N/A 3.45 / 2.5 3.9 N/A N/A N/A 48 10 25 kg litres kg m³/hr mm Wg kW amps amps amps amps 1.8 / 1.8 1.6 170 900 10 6 or 12 30 or 60 9/18 32/63 10 or 20 1.85 / 2.0 1.6 171 900 10 6 or 12 30 or 60 9/18 32/63 10 or 20 2.7 / 2.85 3.2 230 900 10 12/18 60/80 18/27 63/100 20/30 2.65 / 3.0 3.2 240 900 10 12/18 N/A 18/27 N/A 20/30 For accurate application sizing consult CALOREX Heat Pumps Ltd Boiler not required for AA versions without LPHW. MODE A = recovered heat biased to pool water (pool water temp not satisfied) MODE B = recovered heat biased to pool hall air (pool water temp satisfied) R407c Global warming potential (GWP) 1700. Page 30 14.4 AA/AW900 AA/AW1200 AA/AW1500 6·5 8·5 10·1 7·3 9·5 11·3 9·0 11·7 13.9 0 0 0 7.1 10 14 13.5 24 28 18.6 30 36 22.95 40.8 47.6 2.2 2.8 3.3 1 mm WG = 9.8pa 1 Mhd = 1.4psi 1 L/min = 0.22 gall/min SD437360 ISSUE 33 AIR LPHW PERFORMANCE This table shows the difference in performance with temperature and waterflow for all LPHWs, single and double capacity. Percentage of performance or temperature difference. Page 31 SD437360 ISSUE 33 ELEC BOX ASSY SERVICE PANEL 130.00 BOILER WATER IN 3/4" BSPM 120.00 1514.00 MAINS IN THRO' DIA 25mm 2 off 108 75 75 957.00 560.00 115 BOILER WATER OUT 3/4" BSPM SERVICE PANEL 56.00 182 SERVICE PANEL POOL WATER IN 1" BSPM 127.00 DRAIN 3/4" BSPM 60.00 160.00 50.00 615.00 AIR IN ALTERNATIVE AIR OFF POSN'S 60.00 SERVICE PANEL 670.00 AIR OFF STANDARD MACHINE CONFIGURATION 60.00 SERVICE PANEL RESISTANCE HEATER (IF FITTED) IN THIS POSN' ONLY SERVICE PANEL 1310.00 355.00 FRESH AIR BOX SERVICE PANEL DAMPER SEE ABOVE SPIGOTS FRESH AIR BOX 2 SPIGOTS DIAMETER 225mm NEGATIVE PRESSURE BOX 1 SPIGOT DIAMETER 157mm 160.00 MACHINE WITH FRESH AIR OR NEGATIVE PRESSURE BOX AND/OR RESISTANCE HEATER OPTIONS BOILER WATER IN 3/4" BSPM 333.00 BOILER WATER OUT 3/4" BSPM AIR OFF CONSOLE FIXING SERVICE PANEL POOL WATER OUT 1" BSPM SERVICE PANEL AIR FILTER ACCESS PANEL 100.00 662.00 148.00 289.00 1017.00 AIR OFF POOL WATER IN 1" BSPM 289.00 DRAIN 3/4" BSPM 190.00 698.00 POOL WATER OUT 1" BSPM Page 32 AIR FILTER ACCESS PANEL 698.00 843.00 FIX CONSOLE TO CONSOLE MOUNTING SERVICE PANEL OR MOUNT REMOTELY (SEE SECTION 2) 5.0 DIMENSION DRAWINGS 600/900 VERTICAL TOP OUTLET VERSIONS NOTE - FEET (TOP HAT SECTION) CAN BE REMOVED IF REQD ON ALL VERSIONS ( TO REDUCE HEIGHT BY 100mm) SD437360 ISSUE 33 ELEC BOX ASSY 2184.00 SERVICE PANEL 60.00 ELEC BOX ASSY 56.00 180 BOILER WATER OUT 3/4" BSPM BOILER WATER IN 3/4" BSPM 108 75 75 540.00 355.00 289.00 SERVICE PANEL 115 POOL WATER IN 1" BSPM 817.00 1530.00 MAINS IN THRO' DIA 25mm 2 off SERVICE PANEL DRAIN 3/4" BSPM FIX CONSOLE TO CONSOLE MOUNTING SERVICE PANEL OR MOUNT REMOTELY (SEE SECTION 2) 50.00 289.00 AIR OFF SEALING DUCT 662.00 120.00 POOL WATER OUT 1" BSPM 160.00 400.00 333.00 ALTERNATIVE AIR OFF POSN'S AIR IN 615.00 698.00 60.00 SERVICE PANEL BOILER WATER OUT 3/4" BSPM BOILER WATER IN 3/4" BSPM 160.00 FRESH AIR BOX 2 SPIGOTS DIAMETER 225mm NEGATIVE PRESSURE BOX 1 SPIGOT DIAMETER 157mm 355.00 FRESH AIR BOX SERVICE PANEL DAMPER AIR FILTER ACCESS PANEL 670.00 ELEC BOX ASSY 2199.00 SERVICE PANEL RESISTANCE HEATER OPTIONS MACHINE WITH FRESH AIR OR NEGATIVE PRESSURE BOX AND/OR BOTTOM OUTLET VERSION WITH FRESH AIR AND/OR RESISTANCE HEATER OPTIONS AIR OFF SERVICE PANEL RESISTANCE HEATER (IF FITTED) IN THIS POSN' ONLY. POOL WATER IN 1" BSPM 795.00 DRAIN 3/4" BSPM STANDARD MACHINE CONFIGURATION AIR FILTER ACCESS PANEL SERVICE PANEL 100.00 Page 33 305.00 190.00 POOL WATER OUT 1" BSPM SPIGOTS SEE BELOW 600/900 VERTICAL BOTTOM OUTLET VERSIONS AIR OFF SD437360 ISSUE 33 AIR OFF 698.00 AIR OFF ° = = 56.00 182 115 108 75 75 MAINS IN SERVICE PANEL 670.00 112.00 344.00 160.00 50.00 SERVICE PANEL ELEC BOX ASSY SERVICE PANEL SERVICE PANEL 560.00 2024.00 BOILER WATER IN 3/4" BSPM ELEC BOX ASSY BOILER WATER OUT 3/4" BSPM MACHINE WITH FRESH AIR/NEGATIVE PRESSURE BOX AND/OR RESISTANCE HEATER OPTIONS SERVICE PANEL ° 528.00 FIX CONSOLE TO CONSOLE MOUNTING SERVICE PANEL OR MOUNT REMOTELY (SEE SECTION 2) ALTERNATIVE AIR OFF POSN' 1273.70 SERVICE PANEL 130 SERVICE PANEL POOL WATER IN 1" BSPM 120.00 289.00 140.00 = = DRAIN 3/4" BSPM ° POOL WATER OUT 1" BSPM ° RESISTANCE HEATER (IF REQD) IN THIS POSN' ONLY. AIR FILTER ACCESS PANEL BOILER WATER IN 3/4" BSPM 1354.00 POOL WATER IN 1" BSPM 60.00 DRAIN 3/4" BSPM STANDARD MACHINE CONFIGURATION 100.00 BOILER WATER OUT 3/4" BSPM 662.00 148.00 289.00 349.00 POOL WATER OUT 1" BSPM Page 34 FRESH AIR BOX 160.00 615.00 AIR IN AIR OFF SERVICE PANEL SPIGOTS SEE BELOW 355.00 698.00 333.00 AIR FILTER ACCESS PANEL FIX CONSOLE TO CONSOLE MOUNTING SERVICE PANEL OR MOUNT REMOTELY (SEE SECTION 2) ALTERNATIVE AIR OFF POSN'S DAMPER SPIGOT 302 SPIGOT NEGATIVE PRESSURE BOX 1 SPIGOT DIAMETER 157mm 203 FRESH AIR BOX SPIGOT DETAIL (VIEW FROM AIR ON) (2 SPIGOTS) DIAMETER 225mm 187 600/900 HORIZONTAL VERSIONS SD437360 ISSUE 33 190.00 400.00 800.00 698.00 222.00 729.00 355.00 FLOOR DUCT SPIGOT SUPPLIED 800.00 CABINET 627.00 355.00 FLOOR DUCT SPIGOT SUPPLIED 33.00 33.00 CABINET FOOT 698.00 CABINET 698.00 800.00 400.00 149.00 71.00 33.00 171.00 CABINET FOOT 1200/1500 VERTICAL VERSIONS 200.00 71.00 CABINET FOOT 71.00 71.00 33.00 222.00 33.00 171.00 CABINET FOOT CABINET FOOT 400.00 149.00 400.00 200.00 Page 35 784.00 355.00 FLOOR DUCT SPIGOT SUPPLIED 683.00 355.00 FLOOR DUCT SPIGOT SUPPLIED 33.00 1200/1500 HORIZONTAL VERSIONS 1558.00 CABINET 33.00 CABINET FOOT 1354.00 CABINET CABINET FOOT 33.00 CABINET FOOT 600/900 HORIZONTAL VERSIONS CABINET FOOT 600/900 VERTICAL VERSIONS BOTTOM OUTLET VERSIONS SHOWING DUCT TO FLOOR DETAIL SD437360 ISSUE 33 CABINET FOOT SERVICE PANEL 120.00 56.00 182 BOILER WATER IN 1" BSPM 1718.00 AIR OFF 135 125 75 662.00 1059.00 BOILER WATER OUT 1" BSPM 140 POOL WATER IN 1" BSPM SERVICE PANEL DRAIN 3/4" BSPM 60.00 SERVICE PANEL 160.00 AIR FILTER ACCESS PANEL SERVICE PANEL POOL WATER OUT 1" BSPM SERVICE PANEL ELEC BOX ASSY MAINS IN THRO' DIA 25mm 2off 100.00 50.00 772.00 333.00 692.00 AIR IN ALTERNATIVE AIR OFF POSN'S STANDARD MACHINE CONFIGURATION 145.00 289.00 1170.00 60.00 770.00 SERVICE PANEL AIR OFF SERVICE PANEL RESISTANCE HEATER (IF FITTED) IN THIS POSN' ONLY. 1412.00 355.00 FRESH AIR BOX SERVICE PANEL DAMPER SPIGOT SEE ABOVE FRESH AIR BOX 2 SPIGOTS DIAMETER 225mm NEGATIVE PRESSURE BOX 1SPIGOT DIAMETER 157mm MACHINE WITH FRESH AIR OR NEGATIVE PRESSURE BOX AND/OR RESISTANCE HEATER OPTIONS BOILER WATER IN 1" BSPM 289.00 BOILER WATER OUT 1" BSPM 800.00 POOL WATER IN 1" BSPM 800.00 1558.00 130.00 SERVICE PANEL DRAIN 3/4" BSPM Page 36 POOL WATER OUT 1" BSPM 190.00 160.00 AIR FILTER ACCESS PANEL FIX CONSOLE TO CONSOLE MOUNTING SERVICE PANEL OR MOUNT REMOTELY (SEE SECTION 2) 1200/1500 VERTICAL TOP OUTLET VERSIONS SD437360 ISSUE 33 945.00 ELEC BOX ASSY 2488.00 SERVICE PANEL 60.00 920.00 56.00 180 135 289.00 355.00 642.00 125 75 DRAIN 3/4" BSPM BOILER WATER IN 1" BSPM SERVICE PANEL POOL WATER IN 1" BSPM SERVICE PANEL 140 BOILER WATER OUT 1" BSPM 120.00 POOL WATER OUT 1" BSPM FIX CONSOLE TO CONSOLE MOUNTING SERVICE PANEL OR MOUNT REMOTELY (SEE SECTION 2) ELEC BOX ASSY SERVICE PANEL MAINS IN THRO' DIA 25mm 2 off 1734.00 897.00 160.00 50.00 772.00 289.00 AIR OFF SEALING DUCT 400.00 AIR OFF 333.00 ALTERNATIVE AIR OFF POSN'S AIR IN 692.00 800.00 SERVICE PANEL DRAIN 3/4" BSPM POOL WATER IN 1" BSPM BOILER WATER OUT 1" BSPM BOILER WATER IN 1" BSPM 160.00 FRESH AIR BOX 2 SPIGOTS DIAMETER 225mm NEGATIVE PRESSURE BOX 1SPIGOT DIAMETER 157mm 355.00 FRESH AIR BOX SERVICE PANEL DAMPER MACHINE WITH FRESH AIR OR NEGATIVE PRESSURE BOX AND/OR RESISTANCE HEATER OPTIONS SERVICE PANEL RESISTANCE HEATER (IF FITTED) IN THIS POSN' ONLY. POOL WATER OUT 1" BSPM STANDARD MACHINE CONFIGURATION AIR FILTER ACCESS PANEL SERVICE PANEL 100.00 Page 37 356.00 SERVICE PANEL 2503.00 770.00 190.00 AIR FILTER ACCESS PANEL ELEC BOX ASSY SPIGOT SEE BELOW 1200/1500 VERTICAL BOTTOM OUTLET VERSIONS AIR OFF SD437360 ISSUE 33 AIR OFF AIR OFF 60.00 113.00 ° SERVICE PANEL ° 528.00 ALTERNATIVE AIR OFF POSN' SERVICE PANEL = = 800.00 1479.00 56.00 182 135 SERVICE PANEL 125 75 2249.00 SERVICE PANEL MAINS IN 770.00 2328.00 662.00 BOILER WATER OUT 1" BSPM 140 112.00 POOL WATER IN 1" BSPM SERVICE PANEL ELEC BOX ASSY DRAIN 3/4" BSPM 120.00 289.00 140.00 SERVICE PANEL POOL WATER OUT 1" BSPM ° AIR FILTER ACCESS PANEL 50.00 SERVICE PANEL SERVICE PANEL ELEC BOX ASSY SERVICE PANEL 395.00 160.00 BOILER WATER IN 1" BSPM ° 100.00 1558.00 BOILER WATER OUT 1" BSPM 60.00 POOL WATER IN 1" BSPM BOILER WATER IN 1" BSPM RESISTANCE HEATER (IF REQD) IN THIS POSN' ONLY. 772.00 145.00 289.00 400.00 DRAIN 3/4" BSPM Page 38 POOL WATER OUT 1" BSPM STANDARD MACHINE CONFIGURATION 160.00 DAMPER SPIGOT 302 SPIGOT NEGATIVE PRESSURE BOX 1 SPIGOT DIAMETER 157mm 203 FRESH AIR BOX SPIGOT DETAIL (VIEW FROM AIR ON) (2 SPIGOTS) DIAMETER 225mm 187 ALTERNATIVE AIR OFF POSN'S 190.00 MACHINE WITH FRESH AIR OR NEGATIVE PRESSURE BOX AND/OR RESISTANCE HEATER OPTIONS FRESH AIR BOX SERVICE PANEL DAMPER SPIGOT 355.00 692.00 AIR IN AIR OFF 800.00 333.00 AIR FILTER ACCESS PANEL FIX CONSOLE TO CONSOLE MOUNTING SERVICE PANEL OR MOUNT REMOTELY (SEE SECTION 2) 1200/1500 HORIZONTAL VERSIONS SD437360 ISSUE 33 6.0 WARRANTY CONDITIONS The following exclusions apply to the Warranty given by Calorex Heat Pumps Ltd. No claims will be accepted if :- 1.The heat pump is incorrectly sized for the application. 2.The heat pump is installed in any way that is not in accordance with the current procedures as defined by Calorex Heat Pumps Ltd. 3.The heat pump has been worked upon or is adjusted by anyone other than a person authorised to do so by Calorex Heat Pumps Ltd. 4.The air flow to and from the machine is outside the specified limits. 5.The water flow through the machine is outside the specified limits. 6.The water pH level and/or chemical balance is outside the following limits:- Acidity pH Total Alkalinity, as CaCO3 pH ppm 7.2 - 7.8 80 - 120 Total Hardness, as CaCO3 ppm 150 - 250 Total Dissolved Solids ppm 1000 Maximum Salt Content ppm 8000 Free Chlorine Range Free Chlorine Range ppm ppm 1 - 2 Domestic 3 - 6 Commercial Superchlorination max 30ppm for 24 hrs Bromine ppm 2 - 5 Baquacil Ozone ppm ppm 25 - 50 0.9 Max Maximum Copper Content Aquamatic Ionic Purifier ppm ppm 1 2 Max 7.The heat pump has suffered frost damage. 8.The electrical supply is insufficient or in any way incorrect. 9.The fan amps and duct pressure are outside the specified limits. 10. The heat pump must be maintained to the service requirements in section 2.7. For details of extended warranty and maintenance packages please call the service number below. IF IN ANY DOUBT PLEASE ASK Note:- The Reply Paid Warranty Registration Card must be returned, to ensure that the correct warranty is given. If you do not find a Registration Card with your Heat Pump please contact the Calorex Service Department giving your name, address, model & serial number of your heat pump. A card will be sent to you for completion. Email service@calorex.com Web Site http://www.calorex.com 01621 857171 01621 856611 Please give MODEL NUMBER and SERIAL NUMBER of your heat pump when making technical or service enquiries. This will assist in correct diagnosis and ensure service can be provided with the minimum delay. Page 39 SD437360 ISSUE 33 7.0 LOGIC CONTROL CIRCUITS NOTES 1) SIGNAL TO START BOILER PUMP IS VIA TERMINAL BLOCKS 6 & 7 (VOLTAGE FREE SWITCH). SIGNAL TO START POOL FILTER PUMP IS VIA TERMINAL 8 & 9 (VOLTAGE FREE SWITCH). MACHINE WILL BRING ON POOL FILTER PUMP (IF IT IS NOT ALREADY RUNNING) WHENEVER THE COMPRESSOR RUNS OR WATER HEATING IS REQUIRED (SEE NOTE 10). 2) SET POINT OF THERMOSTATS IS REFERRED TO AS THE SWITCHING POINT FOR SIMPLICITY WHEN IN FACT THE RELAY OPERATES AT SET POINT PLUS OR MINUS THE HYSTERESIS. (SEE GRAPHS BELOW). 3) WHEN MACHINE IS ON DEFROST THE FAN STOPS (UNLESS FAN IS ON DUE TO RESISTIVE HEATERS BEING WARM) BUT ALL OTHER FUNCTIONS OPERATE AS NORMAL. 4) IF FRESH AIR SWITCH IS SET TO 'MIN’ THE DAMPERS (AIR BOX) ARE FORCED TO CLOSE AND WILL NOT BE UNDER MACHINE ‘AUTO' CONTROL. 5) AIR STAT NEON (OUT2) WILL SHOW DEMAND ON UNOCCUPIED SETTING BUT NOTHING WILL HAPPEN BECAUSE CONTROL IS BY OUT1 STAGE OF AIR STAT (UNOCCUPIED). 6) TIME CLOCK MUST BE OVERRIDDEN AND UNOCCUPIED (PIPS IN) SELECTED IN ORDER THAT THE REMOTE 12V SWITCHING FEATURE CAN OPERATE. MACHINE TERMINALS 11 & 12 ARE 12VAC OPEN CIRCUIT = UNOCCUPIED CLOSED CIRCUIT = OCCUPIED 7) AUTO PANEL NEON ONLY WORKS WITH AIR BOX FITTED. 8) DEHUMIDIFICATION/AIR HEATING DOES NOT HAPPEN WHEN IN ECONOMY MODE. 9) IF REMOTE ON/OFF LINK (TERMINAL 12 & 13) IS REMOVED MACHINE WILL NOT START. 10) IN ECONOMY MODE WHEN WATER HEATING IS REQUIRED THE POOL PUMP RUNS AND LPHW VALVE OPENS ONCE THE 60 min TIME DELAY HAS TIMED OUT). IN UNOCCUPIED MODE (AND NOT ECONOMY). POOL PUMP AND LPHW WILL ONLY OPERATE ONCE THE TIME CLOCK HAS PIPPED (OCCUPIED) OR DEHUMIDIFICATION STARTS, THEN KEEPS RUNNING UNTIL THE WATER TEMPERATURE IS SATISFIED. 11) RESISTANCE HEATER CAN SOMETIMES REPLACE AIR LPHW. (BOILER PUMP WILL NOT START WITH AIR RESISTANCE HEATING). 12) RCU IS ENERGISED ON AS3 IN OCCUPIED MODE ONLY. RCU FAN WILL START WITH COMPRESSOR, AND CHANGE RCU SOLENOID VALVE FROM A TO B (A CLOSES - B OPENS) UNLESS MACHINE IS IN DEFROST MODE WHICH WILL THEN KEEP VALVE A ENERGISED. 13) TEST SHEETS (CERTIFICATE OF PERFORMANCE) PART NoS A444050 to 57. 14) WHEN FAN IS SET TO CYCLE MODE, FAN ONLY RUNS WHEN MACHINE HAS DEHUMIDIFICATION OR AIR HEATING DEMANDS. CYCLE MODE IS TERMINALS 33 & 34 LINKED (MADE), LINK TERMS 32 & 34 IN CONTINUOUS MODE. 65% DAMPERS OPEN TO MAX X RH1 = DEHUM STAT STAGE 1 OUT2 RH2 DEHUM COMP ON 63% (COMP ON) AL1 ACTUAL RELATIVE HUMIDITY TECNOLOGIC STAT (TLK38) DEHUMIDISTAT EXAMPLE RH2 = DEHUM STAT STAGE 2 HSEt 62% DAMPERS CLOSED TO MIN (DAMPERS OPEN) OUT1 RH1 SET POINT 60%RH 60% COMP OFF SET POINT = 60%RH ADJUSTABLE HSEt = +3% X = HAL1 SET POINT TECNOLOGIC STAT (TLK31) AIR THERMOSTAT EXAMPLE Y OUT3 AS3 AS1 = AIR STAT STAGE 1 (LPHW HEAT AIR) UNOCCUPIED MODE AS2 = AIR STAT STAGE 2 (LPHW HEAT AIR) OCCUPIED MODE AS3 = AIR STAT STAGE 3 (A/C COOL AIR. DAMPERS OPEN) AL2=2.5 ACTUAL AIR TEMPERATURE RCU ON/DAMPERS OPEN TO MAX 30.5 30.0 RCU OFF/DAMPERS CLOSED TO MIN SET POINT LPHW ON OUT1 ADJUSTABLE AS2 27.5 AIR HEATING OFF 24.0 X OUT2 AL1=-4.5 OCCUPIED MODE HSEt=0.5 28.0 LPHW OFF SET POINT 28ºC UNOCCUPIED MODE AS1 23.5 AIR HEATING ON LPHW SET POINT = 28ºC X = HAL1 Y = HAL2 TECNOLOGIC STAT (TLK38) WATER THERMOSTAT EXAMPLE OUT2 WS1 = WATER STAT WS1 26.1 WATER HEAT ON (DEHUM) STAGE 1 (MAX TEMP). AL1 X TEMPERATURE ACTUAL WATER WATER HEAT OFF (DEHUM) 26.3 LPHW OFF 26.0 SET POINT HSEt 26ºC OUT1 WS2 ADJUSTABLE SET POINT 25.8 LPHW ON WS2 = WATER STAT STAGE 2 (LPHW HEAT WATER). SET POINT = 26ºC HSEt = -0.2 X = HAL1 + 1 DISPLAY INCREMENT = 0.5ºC (IE 0.4+0.1) Page 40 SD437360 ISSUE 33 DRG No. D481050 ISS 7 MAINS LIGHT ON LOCATED NEXT TO WATER CONNECTIONS OCCUPIED MODE:- SEE NOTE 6 IS MACHINE IN OCCUPIED MODE UNOCCUPIED MODE:=TIME CLOCK PIPS IN, =TIME CLOCK PIPS OUT, OR TIME CLOCK MANUAL ' I ' OR 12v TERMINALS 10&11 CLOSED. SEE NOTE 6 OR 12v TERMINALS 10&11 OPEN. IS MACHINE IN UNOCCUPIED MODE NO YES IS CONTROL PANEL SWITCH SET TO 'I' NO (O=OFF) YES (I=ON) SEE NOTE 9 YES (I=ON) LINK TO CONTINUOUS (ON TERM' BLOCK 32-34) START FAN IS ECONOMY SWITCH ON NO SEE NOTE 14 SEE NOTE 4 IS FRESH AIR SWITCH SET TO 'AUTO' IS FRESH AIR SWITCH SET TO 'MIN' NO NO IS FRESH AIR SWITCH SET TO 'MAX' FRESH AIR BOX YES IS FRESH AIR SWITCH SET TO 'AUTO' SEE NOTE 7 IS AIR TEMP BELOW AS2 SET POINT YES PANEL AIR NEON OFF SEE NOTE 11 IS AIR TEMP ABOVE AS3 SET POINT AIR & HUMIDITY STATS OFF FAN OFF PANEL AIR NEON OFF IS YES BOILER PUMP ON DUE TO WS2 WATER DEMAND SEE NOTE 1 NO SEE NOTE 11 SEE NOTE 1 OPEN LPHW (TO AIR) VALVE TO HEAT AIR SHUT LPHW (TO AIR) VALVE STOP AIR HEATING SEE NOTE 11 SEE NOTE 2 AIR STAT NEON (OUT3) ON AIR STAT NEON (OUT3) OFF SEE NOTE 2 IS RH% ABOVE RH1 SET POINT YES SEE NOTE 8 IS AIR/WATER PRIORITY SWITCH MADE TO AIR YES IS WATER TEMP BELOW WS2 SET POINT STOP COMPRESSOR R/H STAT NEON (OUT1) ON PANEL D/H NEON OFF SEE NOTE 10 SEND SIGNAL TO STOP POOL PUMP UNLESS WATER HEATING REQD YES WATER STAT NEONS (OUT1&OUT2) ON PANEL WATER NEON ON NO SEND SIGNAL TO START POOL PUMP YES R/H STAT NEON (OUT2) ON IS RH% ABOVE RH2 SET POINT IS NO WATER TEMP ABOVE WS1 & WS2 YES IS WATER TEMP BELOW WS2 SET POINT PANEL D/H NEON OFF PANEL R/H NEON ON SEND SIGNAL TO START POOL PUMP NO SEE NOTE 2 STOP COMPRESSOR R/H STAT NEON (OUT1) ON NO NO SEE SEND SIGNAL NOTE TO STOP POOL 10 PUMP UNLESS WATER HEATING OCCURRING SEE NOTE 10 YES YES WATER STAT NEON (OUT1) OFF WATER STAT NEONS (OUT1&OUT2) ON WATER STAT NEONS OUT 1 & OUT 2 OFF SEE NOTE 8 PANEL WATER NEON OFF IS DEHUM REQD NO DAMPERS TO MAXIMUM FRESH AIR FAN STARTS DAMPERS TO MINIMUM FRESH AIR BOX & FRESH AIR FAN NOT RUNNING IS BOILER PUMP YES ON DUE TO AS1 AIR DEMAND R/H STAT NEON (OUT2) ON WATER STAT NEON (OUT1&OUT2) OFF YES YES R/H STAT NEON (OUT2) OFF SHUT LPHW WATER HEATING VALVE SEE NOTE 1 NO YES SEND SIGNAL TO START BOILER PUMP A SEE NOTE 8 DAMPERS WILL NOT OPEN DUE TO UNOCCUPIED MODE (FRESH AIR BOX) (IF FITTED) DAMPERS CLOSED TO MINIMUM (FRESH AIR BOX) (IF FITTED) HAS TIME CLOCK NIGHT PIP BEEN MADE NO SEND SIGNAL TO START POOL PUMP SEE NOTE NO 1 SEND SIGNAL TO STOP BOILER PUMP SHUT LPHW (TO WATER) VALVE, STOP WATER HEATING SEND SIGNAL TO STOP POOL PUMP UNLESS DEHUMIDIFICATION IS REQD SEE NOTE 8 SEE NOTE 10 OPEN LPHW (TO WATER) VALVE TO HEAT POOL WATER SEE NOTE 8 A IS BOILER PUMP YES ON DUE TO AS1 AIR DEMAND PANEL WATER NEON OFF REV VALVE OPEN (ENERGISED) TO HEAT AIR NO SEE NOTE 8 R/H STAT NEON (OUT2) OFF (IF FITTED) IS FRESH AIR SWITCH SET TO MIN. NO YES WATER STAT NEON (OUT1) OFF SEE NOTE 8 IS WATER TEMP ABOVE WS2 & WS1 NO PANEL WATER NEON ON REV VALVE OPEN (ENERGISED) TO HEAT AIR SEND SIGNAL TO STOP POOL PUMP UNLESS DEHUMIDIFICATION IS REQD REV VALVE OPEN (ENERGISED) TO HEAT AIR (DEHUM) YES NO START COMPRESSOR REV VALVE OPEN (ENERGISED) TO HEAT AIR (DEHUM) SEE NOTE 8 IS AIR/WATER PRIORITY SWITCH MADE TO AIR RH STAT NEONS OUT 1 & OUT 2 OFF NO SEE NOTE 2 IS RH% ABOVE RH2 SET POINT A NO ACTION DUE TO UNOCCUPIED MODE A YES SEND SIGNAL TO START POOL PUMP (IF NOT RUNNING) YES NO IS RCU FITTED RH STAT NEONS OFF OUT1/AND OUT2 PANEL R/H NEON ON SEE NOTE 11 IS AIR TEMP ABOVE AS3 SET POINT IS NO FRESH AIR SWITCH SET TO 'AUTO' IF FITTED IF YES FITTED DAMPERS TO MIN OPEN DAMPERS UNLESS SWITCH TO MAXIMUM SET TO MAX AND FRESH AIR BOX FRESH AIR FAN AND FRESH AIR RUNNING FAN START YES START COMPRESSOR NO SEND SIGNAL TO STOP BOILER PUMP SEND SIGNAL TO START BOILER PUMP SEE SEE NOTE NOTE 12 12 NO AIR STAT NEON (OUT1) OFF IS YES BOILER PUMP ON DUE TO WS2 WATER DEMAND PANEL AIR NEON OFF NO IS RH% ABOVE RH1 SET POINT NO PANEL AIR NEON ON AIR STAT NEON (OUT3) ON AIR STAT NEON (OUT3) OFF AIR STAT NEON (OUT2) OFF AIR STAT NEON (OUT1) ON YES NO AUTO NEON OFF SEE NOTE 5 YES SEE NOTE 11 SEE NOTE 2 YES DAMPERS OPEN TO MAXIMUM FRESH AIR FAN STARTS NO IS AIR TEMP BELOW AS1 SET POINT SHUT LPHW (TO AIR) VALVE STOP AIR HEATING OPEN LPHW (TO AIR) VALVE TO HEAT AIR SEE NOTE 11 MACHINE IS OFF TIME CLOCK & MAINS LIGHT ON COMP', FAN & DISPLAYS OFF. VALVE SHUT. DAMPERS STAY IN POSITION LAST CALLED FOR. YES YES AIR STAT NEON (OUT2) OFF IS IS BOILER BOILER YES PUMP ON PUMP ON DUE TO DUE TO WS2 WS2 WATER WATER DEMAND DEMAND NO NO SEE NOTE 1 SEE NOTE 1 SEND SIGNAL TO SEND SIGNAL TO STOP BOILER PUMP START BOILER PUMP NO AUTO NEON OFF AIR STAT NEON (OUT2) ON PANEL AIR NEON ON IS FRESH AIR SWITCH SET TO 'MAX' YES GREEN AIR & HUMIDITY STATS OFF FAN OFF AIR STAT NEON (OUT1&2) ON NO PANEL AUTO NEON ON NO IS ECONOMY SWITCH ON SEE NOTE 14 FRESH AIR BOX IF FITTED DAMPERS CLOSE TO MINIMUM AUTO NEON OFF AUTO NEON OFF IS FRESH AIR SWITCH SET TO 'MIN' YES DAMPERS OPEN TO MAXIMUM FRESH AIR FAN STARTS DAMPERS CLOSE TO MINIMUM LINK TO CONTINUOUS (ON TERM' BLOCK 32-34) SEE NOTE 4 IF FITTED GREEN IS AIR TEMP BELOW AS2 SET POINT START FAN MACHINE IS OFF TIME CLOCK & MAINS LIGHT ON COMP', FAN & DISPLAYS OFF. VALVE SHUT. DAMPERS STAY IN POSITION LAST CALLED FOR. YES YES YES PANEL AUTO NEON ON NO (O=OFF) SEE NOTE 9 CONTROL PANEL NEON ON CONTROL PANEL NEON ON SEE NOTE 2 NO YES IS CONTROL PANEL SWITCH SET TO 'I' SEE NOTE 7 OR TIME CLOCK MANUAL '0' SEE NOTE 8 IS BOILER PUMP ON YES DUE TO AS1 AIR DEMAND SEE NOTE 1 NO SEND SIGNAL TO START BOILER PUMP IS BOILER PUMP YES ON DUE TO AS1 AIR DEMAND SEE NOTE 1 NO SEND SIGNAL TO STOP BOILER PUMP OPEN LPHW (TO WATER) VALVE TO HEAT POOL WATER CHECK DEFROST MODE SEE NOTES 3 & 12 Page 41 SD437360 ISSUE 33 NOTES 1) SIGNAL TO START BOILER PUMP IS VIA TERMINAL BLOCKS 6 & 7 (VOLTAGE FREE SWITCH). 2) "SET POINT" OF THERMOSTATS IS REFERRED TO AS THE SWITCHING POINT FOR SIMPLICITY WHEN IN FACT THE RELAY OPERATES AT SET POINT, PLUS OR MINUS THE HYSTERESIS. (SEE GRAPHS BELOW). 3) WHEN MACHINE IS ON DEFROST THE FAN STOPS BUT ALL OTHER FUNCTIONS OPERATE AS NORMAL. 4) IF FRESH AIR SWITCH IS SET TO 'MIN' THE DAMPERS (AIR BOX) ARE FORCED TO CLOSE AND WILL NOT BE UNDER MACHINE 'AUTO' CONTROL. 5) AIR STAT NEON (OUT2) WILL SHOW DEMAND ON UNOCCUPIED SETTING BUT NOTHING WILL HAPPEN BECAUSE CONTROL IS BY OUT1 STAGE OF AIR STAT (UNOCCUPIED) 6) TIME CLOCK MUST BE OVERRIDDEN AND UNOCCUPIED (PIPS IN) SELECTED IN ORDER THAT THE REMOTE 12v SWITCHING FEATURE CAN OPERATE. MACHINE TERMINALS 10 & 11 ARE 12vac, OPEN CIRCUIT = UNOCCUPIED, CLOSED CIRCUIT = OCCUPIED. 7) PANEL AUTO NEON (GREEN) ONLY WORKS WHEN AIR BOX FITTED. 8) IF REMOTE ON/OFF LINK (TERMINAL 12 & 13) IS REMOVED MACHINE WILL NOT START. 9) RESISTANCE HEATER CAN SOMETIMES REPLACE AIR LPHW. (BOILER PUMP WILL NOT START WITH AIR RESISTANCE HEATING). 10) R.C.U. IS ENERGISED ON AS3 IN OCCUPIED MODE ONLY. (R.C.U. FAN WILL START) WITH COMPRESSOR, AND CHANGE R.C.U. SOLENOID VALVES FROM A TO B (A CLOSES - B OPENS) UNLESS M/C IS IN DEFROST MODE WHICH WILL THEN KEEP VALVE A ENERGISED. 11) WHEN FAN IS SET TO CYCLE MODE, FAN ONLY RUNS WHEN MACHINE HAS DEHUMIDIFICATION OR AIR HEATING DEMANDS. CYCLE MODE IS TERMINALS 33 & 34 LINKED (MADE). FIT LINK BETWEEN TERMS 32 & 34 TO RUN MACHINE IN CONTINUOUS MODE. OCCUPIED MODE:- UNOCCUPIED MODE:- =TIME CLOCK PIPS OUT, OR TIME CLOCK MANUAL 'I' OR 12V TERMINALS 10&11 CLOSED. =TIME CLOCK PIPS IN, OR TIME CLOCK MANUAL '0' OR 12V TERMINALS 10&11 OPEN. RH2 = DEHUM STAT STAGE 2 (DAMPERS OPEN) AS1 = AIR STAT STAGE 1 (LPHW HEAT AIR) UNOCCUPIED MODE AS2 = AIR STAT STAGE 2 (LPHW HEAT AIR) OCCUPIED MODE AS3 = AIR STAT STAGE 3 (A/C COOL AIR. DAMPERS OPEN) DEHUMIDISTAT EXAMPLE AIR THERMOSTAT EXAMPLE TECNOLOGIC STAT (TLK31) 60%RH 27.5 LPHW ON AIR HEATING OFF 24.0 60% COMP OFF ADJUSTABLE SET POINT X SET POINT OUT1 AS1 23.5 AIR HEATING ON LPHW OUT2 AS2 AL2=2.5 SET POINT RH1 AD JUSTABLE Y OUT1 AL1=-4.5 HSEt 28.0 LPHW OFF OCCUPIED MODE SET POINT 28ºC 62% DAMPERS CLOSED TO MIN OUT3 AS3 30.0 RCU OFF/DAMPERS CLOSED TO MIN HSEt=0.5 OUT2 RH2 AL1 DEHUM COMP ON 63% RCU ON/DAMPERS OPEN TO MAX STOP COMP IF NO DAMPERS/RCU 30.5 ACTUAL AIR TEMPERATURE DAMPERS OPEN TO MAX 65% X ACTUAL RELATIVE HUMIDITY TECNOLOGIC STAT (TLK38) UNOCCUPIED MODE SET POINT = 60%RH HSEt = +3% X = HAL1 SET POINT = 28ºC X = HAL1 Y = HAL2 Page 42 SD437360 ISSUE 33 MAINS LIGHT ON LOCATED NEXT TO WATER CONNECTIONS SEE NOTE 6 IS MACHINE IN OCCUPIED MODE SEE NOTE 6 IS MACHINE IN UNOCCUPIED MODE NO YES YES IS CONTROL PANEL SWITCH SET TO 'I' IS CONTROL PANEL SWITCH SET TO 'I' NO (O=OFF) YES (I=ON) SEE NOTE 8 NO (O=OFF) YES (I=ON) CONTROL PANEL NEON ON START FAN NO CONTROL PANEL NEON ON LINK TO CONTINUOUS (ON TERM' BLOCK 32-34)SEE NOTE 11 LINK TO CONTINUOUS (ON TERM' BLOCK 32-34) START FAN SEE NOTE 4 SEE NOTE 11 SEE NOTE 4 IS FRESH AIR SWITCH SET TO 'AUTO' IS FRESH AIR SWITCH SET TO 'MIN' NO IS FRESH AIR SWITCH SET TO 'MAX' NO YES YES DAMPERS CLOSE TO MINIMUM DAMPERS OPEN TO MAXIMUM FRESH AIR FAN STARTS AUTO NEON OFF AUTO NEON OFF YES MACHINE IS OFF. TIME CLOCK & MAINS LIGHT ON. COMP', FAN & DISPLAYS OFF. VALVE SHUT. DAMPERS STAY IN POSITION LAST CALLED FOR. SEE NOTE 7 FRESH AIR BOX IF FITTED PANEL AUTO NEON ON GREEN IS FRESH AIR SWITCH SET TO 'AUTO' IS FRESH AIR SWITCH SET TO 'MIN' NO YES IS FRESH AIR SWITCH SET TO 'MAX' NO YES YES DAMPERS CLOSE TO MINIMUM DAMPERS OPEN TO MAXIMUM FRESH AIR FAN STARTS AUTO NEON OFF AUTO NEON OFF MACHINE IS OFF. TIME CLOCK & MAINS LIGHT ON. COMP', FAN & DISPLAYS OFF. VALVE SHUT. DAMPERS STAY IN POSITION LAST CALLED FOR. FRESH AIR BOX IF FITTED PANEL AUTO NEON ON GREEN SEE NOTE 2 IS AIR TEMP BELOW AS2 SET POINT NO SEE NOTE 5 IS AIR TEMP BELOW AS2 SET POINT YES AIR STAT NEON (OUT1&2) ON AIR STAT NEON (OUT2) OFF PANEL AIR NEON ON NO YES PANEL AIR NEON OFF AIR STAT NEON (OUT2) OFF SEE NOTE 1 SEE NOTE 1 SEND SIGNAL TO START BOILER PUMP SEND SIGNAL TO STOP BOILER PUMP SEE NOTE 9 IS AIR TEMP BELOW AS1 SET POINT SEE NOTE 9 SEE NOTE 9 YES SEE NOTE 9 OPEN LPHW (TO AIR) VALVE TO HEAT AIR NO SHUT LPHW (TO AIR) VALVE TO STOP AIR HEATING PANEL AIR NEON OFF PANEL AIR NEON ON SEE NOTE 2 AIR STAT NEON (OUT1) OFF AIR STAT NEON (OUT1) ON IS AIR TEMPABOVE AS3 SET POINT YES SEE NOTE 1 AIR STAT NEON (OUT3) ON SEE NOTE 1 NO SEE NOTE 9 IS FRESH AIR BOX FITTED YES YES IF FITTED OPEN DAMPERS TO MAXIMUM FRESH AIR BOX AND FRESH AIR FAN STARTS NO SEND SIGNAL TO STOP BOILER PUMP SEE NOTE 9 SEE NOTE 9 SEE NOTE 9 OPEN LPHW (TO AIR) VALVE TO HEAT AIR AIR STAT NEON (OUT3) OFF IS FRESH AIR SWITCH SET TO 'AUTO' SEND SIGNAL TO START BOILER PUMP NO SHUT LPHW (TO AIR) VALVE STOP AIR HEATING SEE NOTE 2 IF FITTED DAMPERS TO MIN UNLESS SWITCH AND FRESH AIR FAN RUNNING IS AIR TEMP ABOVE AS3 SET POINT YES AIR STAT NEON (OUT3) ON NO YES AIR STAT NEON (OUT3) OFF NO IS RH% ABOVE RH1 SET POINT IS RCU FITTED YES SEE NOTE 10 NO RH STAT NEONS OUT1 AND OUT2 OFF YES NO ACTION DUE TO UNOCCUPIED MODE IS RCU FITTED IS RH% ABOVE RH1 SET POINT STOP COMPRESSOR NO STOP COMPRESSOR START COMPRESSOR R/H STAT NEON (OUT1) ON PANEL D/H NEON OFF PANEL D/H NEON OFF PANEL R/H NEON ON IS RH% ABOVE RH2 SET POINT NO IS RH% ABOVE RH2 SET POINT YES R/H STAT NEON (OUT2) ON IF FITTED IS FRESH AIR SWITCH SET TO MIN. YES DAMPERS TO NO MAXIMUM FRESH AIR BOX AND FRESH AIR FAN START RH STAT NEONS OUT1 & 2 OFF YES R/H STAT NEON (OUT1) ON PANEL R/H NEON ON NO SEE NOTE 2 NO STOP COMPRESSOR YES START COMPRESSOR IS FRESH AIR BOX OR RCU FITTED NO YES IF FITTED R/H STAT NEON (OUT2) ON DAMPERS CLOSED TO MINIMUM FRESH AIR BOX AND FRESH AIR FAN NOT RUNNING (IF FITTED) DAMPERS WILL NOT OPEN DUE TO MINIMUM UNOCCUPIED MODE (FRESH AIR BOX) (IF FITTED) DAMPERS CLOSED TO MINIMUM (FRESH AIR BOX) CHECK DEFROST MODE SEE NOTES 3 & 10 Page 43 SD437360 ISSUE 33 NOTES 1) "SET POINT" OF DIGITAL CONTROLLERS IS REFERRED TO AS THE SWITCHING POINT FOR SIMPLICITY WHEN IN FACT THE RELAY OPERATES AT SET POINT PLUS OR MINUS THE HYSTERESIS. (SEE GRAPHS BELOW). 2) WHEN MACHINE IS ON DEFROST, FAN STOPS BUT ALL OTHER FUNCTIONS OPERATE AS NORMAL. 3) IF FRESH AIR SWITCH IS SET TO 'MIN' THE DAMPERS (AIR BOX) ARE FORCED TO CLOSE AND WILL NOT BE UNDER MACHINE 'AUTO' CONTROL. 4) PANEL AUTO NEON (GREEN) ONLY WORKS WHEN AIR BOX FITTED. 5) IF REMOTE ON/OFF LINK (TERMINAL 12 & 13) IS REMOVED MACHINE WILL NOT START. 6) RCU IS ENERGISED ON AS2, RCU FAN WILL START WITH COMPRESSOR, AND CHANGE RCU SOLENOID VALVES FROM A TO B (A CLOSES - B OPENS) UNLESS M/C IS IN DEFROST MODE WHICH WILL THEN KEEP VALVE A ENERGISED. 7) WHEN FAN IS SET TO CYCLE MODE, FAN ONLY RUNS WHEN MACHINE HAS DEHUMIDIFICATION OR AIR HEATING DEMANDS. CYCLE MODE IS TERMINALS 33 & 34 (LINKED (MADE) LINK TO TERMS 32 & 34 IN CONTINUOUS MODE.8) IF REMOTE ON/OFF LINK (TERMINAL 12 & 13) IS REMOVED MACHINE WILL NOT START. RH1 = DEHUM STAT STAGE 1 (COMP ON) RH2 = DEHUM STAT STAGE 2 (DAMPERS OPEN) AS1 = AIR STAT STAGE 1 (HEAT AIR). AS2 = AIR STAT STAGE 2 (A/C COOL AIR. DAMPERS OPEN). TECNOLOGIC STATS (TLK38) AIR THERMOSTAT EXAMPLE 60%RH AL1 =0.5 HAL1 30.0 RCU OFF/DAMPERS CLOSED TO MIN 60% COMP OFF =0.5 SET POINT 28ºC OUT1 RH1 SET POINT OUT2 AS2 LPHW OFF 28.0 HSEt =3 ACTUAL AIR TEMPERATURE OUT2 RH2 62% DAMPERS CLOSED TO MIN HSEt RCU ON/DAMPERS OPEN TO MAX STOP COMP IF NO DAMPERS OR RCU 30.5 AL1 DEHUM COMP ON 63% =3 DAMPERS OPEN TO MAX 65% HAL1 ACTUAL RELATIVE HUMIDITY DEHUMIDISTAT EXAMPLE OUT1 AS1 ADJUSTABLE SET POINT 27.5 LPHW ON ADJUSTABLE SET POINT SET POINT = 60%RH SET POINT = 28ºC Page 44 SD437360 ISSUE 33 MAINS LIGHT ON LOCATED NEXT TO WATER CONNECTIONS IS NO (O=OFF) CONTROL PANEL SWITCH SET TO 'I' YES (I=ON) CONTROL PANEL NEON ON SEE NOTE 5 START FAN LINK TO CONTINUOUS (ON TERM' BLOCK 32-34) SEE NOTE 7 SEE NOTE 3 IS FRESH AIR SWITCH SET TO 'AUTO' NO IS FRESH AIR SWITCH SET TO 'MIN' YES SEE NOTE 4 IS FRESH AIR SWITCH SET TO 'MAX' NO MACHINE IS OFF. MAINS LIGHT ON. COMP', FAN & DISPLAYS OFF. DAMPE RS STAY IN POSITION LAST CALLED FOR. YES YES FRESH AIR BOX IF FITTED DAMPERS CLOSE TO MINIMUM PANEL AUTO NEON ON DAMP ERS OPEN TO MAXIMUM FRESH AIR FAN STARTS AUTO NEON OFF AUTO NEON OFF GREEN SEE NOTE 2 IS AIR TEMP BELOW AS1 SET NO POINT YES AIR STAT NEON (OUT1) ON AIR STAT NEON (OUT1) OFF PANEL AIR NEON ON PANEL AIR NEON OFF SEE NOTE 2 IS AIR TEMP ABOVE AS2 SET POINT YES NO AIR STAT NEON (OUT2) ON PANEL AIR NEON OFF IS FRESH AIR BOX FITTED AIR STAT NEON (OUT2) OFF NO YES IS FRESH AIR SWITCH SET TO 'AUTO' NO YES TO DAMPERS OPEN MAXIMUM FRESH AIR BOX NO IS RCU FITTED DAMPE RS CLOSED TO MINIMUM FRESH AIR BOX YES SEE NOTE 6 YES IS RCU FITTED NO IS RH% ABOVE RH1 SET POINT NO STOP COMP' YES PANEL D/H NEON OFF PANEL R/H NEON ON R/H STAT NEON (OUT1) ON START COMPRESSOR IS RH% ABOVE RH2 SET POINT STOP COMPRESSOR NO YES R/H STAT NEON (OUT2) ON FRESH AIR BOX IF FITTED IS FRESH AIR SWITCH SET TO MINIMUM NO OPEN TO DAMPE RS MAXIMUM FRESH AIR BOX FRESH AIR FAN STARTS DAMPERS CLOSED TO MINIMUM FRESH AIR BOX YES CHECK DEFROST MODE SEE NOTES 2 & 6 Page 45 SD437360 ISSUE 33 7.1 RELAY FUNCTIONS R1 Energised on power on switch being made on AA and AA+LPHW /resistance heating. Energised on power on switch being made and economy switch in the full operation mode on the AW. When not energised and the machine is switched on allows the pool pump & water LPHW to operate in economy mode once 60 min timer on AW machine (if fitted) has timed out, when water temperature is below stage 1. R2 Energised when stage 1 (unoccupied) or stage 2 in occupied mode. Air heating is needed bring on the LPHW air valve or resistance heater (used on AA machine to bring on the fan if air is below stage 1. R4 has to be made in occupied mode). It will also bring on the fan on all machines if fan is not already running. R3 Energised when dehumidification is needed as long as LP and HP pressure switches are not in fault mode. R4 Energised when time clock is in occupied mode on AA+LPHW / resistance heating and AW machine. On AA with air box or RCU energised once the power switch is made. R5 Energised on humidity still rising above stage 2, which in turn will open the dampers (only if air box is fitted and R4 is energised). R6 Energised when damper switch on control panel is switched from auto mode (only if air box is fitted). R7 Energised to switch the air box to max (if air box is fitted). R8 Energised when water temperature is above stage 2 it energise the reversing valve to send dehumidification heat to air (AW machine only). R9 Energised if LPHW water heating is required to start the pool pump only in the occupied mode and economy mode or if at any time dehumidification is happening (AW machine only). R10 Energised by relay 9 to bring on water LPHW valve. Only if water temperature is below stage 1 in occupied mode only. (AW machine only). R11 Used on AA / AA+LPHW / resistance heating machine without options to stop dehumidification once air temperature is above stage 2 on AA machine, above stage 3 on AA+LPHW / resistance heating. R12 Used only if RCU unit is fitted energised if air temperature is above stage 2 on an AA machine with out time clock or stage 3 on all other machines. R13 Used only on AW machine to start LPHW water heating and pool pump if water temperature is below stage 1 in the occupied mode only. R14 Provides volt free contacts for remote ‘control power’ indication. RE 1 Energised by R2 to bring on the fan when the fan is wired to cycle mode when air temperature is low. RE 2 Energised in defrost mode to bring on defrost lamp and if RCU is fitted to change back to valve A if RCU is calling for, valve B when machine is in defrost mode. RE 3 Energised once R1 is made unless the soft start has a fault or soft start link is broken. Which would cause RE 3 to drop out bring on the fault lamp. RE 4 Provides volt free contacts for fan running. Page 46 SD437360 ISSUE 33 7.2 PARAMETER SETTINGS SETTING INSTRUCTIONS (TECNOLOGIC STATS,TLK 38, TLK 31) NOTE : These parameter settings are programmed by the supplier to the figures shown below and should not need altering. See Section 3.2 for description of how to alter customer settings. 1a. To Program the Set Point (Humidity and Water). Press down P, SP1 and Set Point value (e.g. 60) will be displayed alternately. Press the or key to change the value of SP1. Once the desired value is displayed press P to memorise the value. The display will revert to the present reading. NOTE : If anything else shows on the display leave alone for 1 minute, until the display returns to normal. 1b. To Program the Set Point (Air) Press down P, SP1 and Set Point value (e.g 28) will be displayed alternately. Press ‘P’ again, AL1 and AL1 value (-4.5) will be displayed alternately. This is the difference between the Set Point and AL1 plus HSEt e.g 28-4.5+0.5 = 24ºC Night set back or unoccupied temperature. SP1 and AL1 can be changed in the same way as described above for all Variheats 2. To Program the Parameters. Press and hold down the P key for approximately 2 seconds. You will enter the Programme Control Group Menu. Press the key to reach ConF, then press P again. Enter the Password -281 by holding the key. If you pass -281 press the key to go back, then press P again, this will take you into the Programmable Group Menu. Press the or key to get into the relevant group and press P again. You should now be at the first parameter of that group. To read or change the setting press P, then to change the setting (if needed) press the or key. Once the correct setting is reached press P again. To move to the next setting press the or key and repeat above. *NOTE Some functions are not present, either because they are instrument dependant or because they are disabled. To return to Programmable Group Menu leave keys alone for 20 seconds approx. To return to Normal Mode leave alone for a further 20 seconds approx. PARAMETER FUNCTION NAME WATER SETTING AIR AIR NO AIR HEATING AIR HEATING HUMIDITY GROUP כSP (RELATIVE TO SET POINT ) CAN BE SET FROM KEYPAD nSP FACTORY SETTING 1 1 1 1 SP1 SET POINT 1 26.0 28.0 28.0 60 SPLL FACTORY SETTING 10.0 10.0 10.0 15 SPHL FACTORY SETTING 40.0 40.0 40.0 80 Ptc Ptc 0.10 GROUP כInP (RELATIVE TO THE MEASURED OUTPUT ) SEnS FACTORY SETTING Ptc * SSC FACTORY SETTING 0 * FSC FACTORY SETTING 100 dp FACTORY SETTING 1 1 1 * Unit FACTORY SETTING ºC ºC ºC FiL FACTORY SETTING 1 1 1 OFF Fild FACTORY SETTING OFF OFF OFF OFF OFSt MEASURING OFFSET 0.0 0.0 0.0 0 rot FACTORY SETTING 1.000 1.000 1.000 1.000 InE FACTORY SETTING Our Our Our Our OPE FACTORY SETTING 0 0 0 0 * Dif FACTORY SETTING 0 noF GROUP כOut (RELATIVE TO OUTPUTS) 01F FACTORY SETTING 1.rEG 1.rEG ALno 1.rEG 02F FACTORY SETTING Alnc ALno 1.rEG ALno * 03F FACTORY SETTING ALno * 04F FACTORY SETTING ALno Page 47 SD437360 ISSUE 33 PARAMETER FUNCTION NAME SETTING AIR AIR WATER NO AIR HEATING AIR HEATING HUMIDITY GROUP כAL1 (RELATIVE TO ALARM AL1) OAL1 OUTPUT, ALARM AL1 ADDRESSED Out2 Out2 Out1 Out2 AL1T FACTORY SETTING LodE HidE LodE HidE Ab1 FACTORY SETTING 0 0 0 0 AL1 ALARM AL1 THRESHOLD 0.1 2.5 -4.5 5 AL1L FACTORY SETTING -199.0 -199.0 -10.0 -1999 AL1H FACTORY SETTING 999.0 999.0 -1.0 9999 HAL1 ALARM AL1 HYSTERESIS 0.2 0.5 0.5 3 AL1d FACTORY SETTING OFF OFF OFF OFF AL1i FACTORY SETTING no no no no GROUP כAL2 (RELATIVE TO ALARM AL2) * 0AL2 OUTPUT, ALARM AL2 ADDRESSED Out3 * AL2t FACTORY SETTING HidE * Ab2 FACTORY SETTING 0 * AL2 ALARM AL2 THRESHOLD * AL2L FACTORY SETTING -199.0 * AL2H FACTORY SETTING 999.0 * HAL2 ALARM AL2 HYSTERESIS 0.5 * AL2d FACTORY SETTING OFF * AL2i FACTORY SETTING no 2.5 GROUP כAL3 (RELATIVE TO ALARM AL3) * 0AL3 OUTPUT, ALARM AL3 ADDRESSED Out4 * AL3t FACTORY SETTING HidE * Ab3 FACTORY SETTING 0 * AL3 ALARM AL3 THRESHOLD * AL3L FACTORY SETTING -199.0 * AL3H FACTORY SETTING 999.0 * HAL3 ALARM AL3 HYSTERESIS * AL3d FACTORY SETTING OFF * AL3i FACTORY SETTING no 4.5 0.5 GROUP כLBa (RELATIVE TO LOOP BREAK ALARM) 0LbA FACTORY SETTING OFF OFF OFF OFF LbAt FACTORY SETTING OFF OFF OFF OFF Page 48 SD437360 ISSUE 33 PARAMETER FUNCTION SETTING NAME AIR AIR WATER NO AIR HEATING AIR HEATING HUMIDITY GROUP כrEG (RELATIVE TO CONTROL) Cont FACTORY SETTING On.FA On.FA On.FA On.FA Func FACTORY SETTING HEAt HEAt HEAt CooL HSEt FACTORY SETTING 0.2 0.5 0.5 3 SloR FACTORY SETTING 1nF 1nF 1nF 1nF dur.t FACTORY SETTING 1nF 1nF 1nF 1nF SLoF FACTORY SETTING 1nF 1nF 1nF 1nF GROUP PAn (RELATIVE TO USER INTERFACE) NOTE USrb FACTORY SETTING noF noF noF noF disP FACTORY SETTING dEF dEF dEF dEF AdE FACTORY SETTING OFF OFF OFF OFF Edit FACTORY SETTING SAE SAE SAE SAE Any group or parameter not shown on list should be left as factory setting. SWITCHING POINTS OUT1 SET POINT OUT2 ON OFF OUT3 ON OFF ON OFF RELATIVE HUMIDITY = 60% 63 60 65 62 --- AIR TEMPERATURE = 28ºC 23.5 24.0 27.5 28.0 30.5 WATER TEMPERATURE = 26ºC 25.8 26.0 26.1 26.3 --- ERROR "---" PROBE INTERRUPTED --30.0 --- ACTION "uuuu" OR "oooo" PROBE LIMIT UNDER/OVER RANGE VERIFY CORRECT CONNECTION BETWEEN PROBE AND STAT, THEN VERIFY CORRECT FUNCTIONING OF PROBE. LbA LOOP CONTROL INTERRUPTED CHECK WORKING OF PROBE AND ACTUATOR AND SWAP INSTRUMENT TO rEG CONTROL ErEP POSSIBLE ANOMALY OF EPROM MENU PUSH P KEY Programming the offset If the reading on the digital controller is not the same as the actual pool hall air temperature, water temperature or relative humidity, it may be necessary to program the offset. Press and hold the P key for approximately 2 seconds. You will then enter the programme control group menu. Press the up key to reach ConF, then press P again and enter the password -281 by holding the down key. If you pass -281 use the up key to go back, then press P again. This takes you into the programmable group menu. Press the up or down key to get to groupInP and then press P again. Press the up key until OFSt is displayed. This parameter can be adjusted by pressing the P key and then the up and down key until the Tecnologic stat reading and the actual reading are the same. Example: If the Pool water is 26.0ºC and the digital controller reads 25.5ºC the offset to be entered is +0.5. When the correct offset has been inserted, leave the stat alone for 20 seconds and the display will return to normal. Great care should be taken to leave all other parameters at their factory settings. Page 49 SD437360 ISSUE 33 SETTING INSTRUCTIONS (TECNOLOGIC STATS,TLZ11) NOTE : These parameter settings are programmed by the supplier ready for use. The parameter tables below should only be needed for reference. See Section 3.2 for description of how to alter customer settings. 1a. To Program the Set Point (Air and Water). Press down P, SP1 and Set Point value (e.g. 60) will be displayed alternately. Press the or key to change the value of SP1. Once the desired value is displayed press P to memorise the value. The display will revert to the present reading. NOTE : If anything else shows on the display leave alone for 1 minute, until the display returns to normal. 2. To program the parameters.Press and hold the P key for approximately 2 seconds, until the display shows ‘0’, the programme control menu. Enter the password 281 by holding thekey. If you pass 281 press the key to go back. Then press P again. This will take you into the programmable menu. To read or change the setting press P, then to change the setting (if needed) press the or key. Once the correct setting is reached press P again. To move to the next setting press the or key and repeat above. To return to normal mode leave alone for a further 20 seconds approx. PARAMETER NAME SPLL SPHL SEnS OFS Unit dp FiL HSEt tonE toFE Func PSC PtC od HAL LAL daL Ald PAL dald Usrb PASS SP FUNCTION MINIMUM SET POINT MAXIMUM SET POINT PROBE TYPE PROBE CALIBRATION UNIT OF MEASUREMENT DECIMAL POINT MEASUREMENT FILTER DIFFERENTIAL ACTIVE TIME OUTPUT OUT FOR PROBE BROKEN DEACTIVATION TIME OUTPUT FOR PROBE BROKEN FUNCTION MODE OUPUT OUT TYPE OF COMPRESSOR PROTECTION: 1 = DELAY AT SWITCH ON 2 = DELAY AFTER SWITCH ON 3 = DELAY BETWEEN STARTS COMPRESSOR PROTECTION TIME DELAY AT POWER ON RELATIVE HIGH TEMPERATURE ALARM THRESHOLD RELATIVE LOW TEMPERATURE ALARM THRESHOLD TEMPERATURE ALARM DIFFERENTIAL TEMPERATURE ALARM DELAY TEMPERATURE ALARM DELAY AT POWER ON FUNCTION MODE KEY U: OFF = NO FUNCTION 1 = ON/STAND-BY ACCESS PASSWORD TO PARAMETER FUNCTIONS SET POINT SET POINT WATER AIR 10 40 Ptc 0.0 OC ON OFF 0.2 OFF OFF HEAT 1 10 40 Ptc 0.0 OC ON OFF 0.5 OFF OFF HEAT 1 OFF OFF 0.3 OFF 0.2 OFF OFF 1 OFF OFF OFF 2.5 OFF 0.5 OFF OFF 1 OFF 281/381 26 281 28 SWITCHING POINTS OUT 1 OUT 2 ON OFF ON OFF AIR TEMPERATURE 28ºC 27.5 28.0 30.5 30.0 WATER TEMPERATURE 26ºC 25.8 26.0 26.1 26.3 Page 50 SD437360 ISSUE 33 SETTING INSTRUCTIONS (STORK STATS) NOTE: THESE PARAMETER SETTINGS ARE SET BY CALOREX AT THE FACTORY TO THE FIGURES SHOWN BELOW AND SHOULD NOT NEED ALTERING. SEE SECTION 3.2 FOR DESCRIPTION OF HOW TO ALTER CUSTOMER SETTINGS. 1. WITH MAINS LIGHT ON, PRESS DOWN TOGETHER AND HOLD. 2. WHEN 'P1' IS DISPLAYED PRESS 3. PRESS AND HOLD AND HOLD UNTIL 'P32' IS DISPLAYED. ,WHEN 'PA' APPEARS PRESS TOGETHER UNTIL 'A1' APPEARS. 4. PRESS AND HOLD 'SET' TO SHOW SETTING AND ALTER USING OR . WHEN REQUIRED SETTING DISPLAYED RELEASE 'SET' AND MOVE TO 'A2' USING 5. REPEAT ABOVE PROCEDURE TO TABLE BELOW UNTIL ALL 'A' SETTINGS COMPLETED 6. PRESS AND HOLD UNTIL 'P1' APPEARS, THEN PRESS 'SET' TO SHOW SETTING. 7. REPEAT 'P' SETTINGS AS 'A' SETTING PROCEDURE. 8. WHEN ALL SETTINGS COMPLETED CONTROL WILL REVERT TO NORMAL DISPLAY. PARAMETER P1 P2 P3 P4 P5 P6 P19 P30 P31 P32 A1 A2 A3 A4 A5 A6 A8 A9 A10 A11 A19 A20 A30 A31 A40 A41 A50 A51 A52 A53 A54 A55 A60 A70 A80 A90 A91 A92 A93 FUNCTION WATER DELTA 'T' IN DEGREES CENTIGRADE BETWEEN THERMOSTAT STAGE 1 & STAGE 2 DIFFERENTIAL OF THERMOSTAT STAGE 1. DIFFERENTIAL OF THERMOSTAT STAGE 2. CUSTOMER SETTING LIMIT (LOW ER) CUSTOMER SETTING LIMIT (HIGHER) ACTUAL TEMP DISPLAY ADJUSTMENT. KEYBOARD LOCK 1, UNLOCK 0 N/A (LOWER BOUNDARY VALUE K3) N/A (UPPER BOUNDARY VALUE K3) K3 HYSTERISIS SWITCH MODE K1 SWITCH MODE K2 0 = HEATING 1 = COOLING 0 = HEATING 1 = COOLING 0 = 0N,SWITCH OFF 1 = ON,SWITCH ON 0 = OFF 1 = ON SEP = 0 K1 TO K2 SEPARATE OR DELTA T T=1 0 = THERMOSTAT 2 = K1 RAMP CONTROL MODE K1 3 = K1 RAMP OBSOLETE DISPLAY MODE 1 = WITH DECIMAL PLACES 1,2,3 ETC 0 = WITHOUT DECIMAL PLACES SENSOR ERROR FUNCTION K1 SENSOR ERROR FUNCTION K2 W EIGHTING FACTOR 50...150% VOLTAGE INPUT Tu VOLTAGE INPUT To PARAMETER SETTINGS KEYPAD BLEEP 0 = NOT LOCKED, 1 = 'A' LOCKED 2 = 'A' & 'P' LOCKED 1 = ON 0 = OFF N/A N/A 0 = HYSTERISIS SYMETRICAL ABOUT SET POINT 1 = OR ONE SIDE OF SET POINT HEATING = BELOW SET POINT COOLING = ABOVE SET POINT AS ABOVE FOR K2 MINIMUM ON TIME K1 MINIMUM OFF TIME K1 MINIMUM ON TIME K2 MINIMUM OFF TIME K2 TIME DELAY K1/K2 AFTER POWER ON TIME DELAY AFTER K1 BEFORE K2 ALLOW ED TO SWITCH ON. SENSOR TYPE. TERMINALS '10' & '11' (FIXED) SOFTWARE TIME CONSTANT. TIME FOR DISPLAY/CONTROL TO REACH NEW VALUE 1=C 0=F N/A N/A N/A N/A Page 51 -0.2 0.2 0.2 20.0 40 0.0 0 0.0 0.0 1 0 0 0 0 1 0 1 100 N/A N/A 0 0 0 0 SETTING HUMIDITY AIR 2 STAGE ONLY 2.0 0.6 0.6 20.0 40 0.0 0 0.0 0.0 1 0 0 0 0 1 0 1 100 N/A N/A 0 0 0 0 3 5 5 15 80 0 0 -10 10 1 1 1 0 0 1 0 0 100 0 100 0 0 0 0 0 0 0 0 1.0 1.0 1.0 1.0 15 0.0 21 3 1 1 1 0 7 0 1.0 1.0 1.0 1.0 15 0.0 21 3 1 1 1 0 7 0 1 1 1 1 15 0 32 3 N/A 1 1 0 7 SD437360 ISSUE 33 BAND SOUND PRESSURE LEVEL (dB) Page 52 20 30 40 50 60 70 80 31.5 ON E D SI FF AI R AIR O 63 125 BACKGROUND BACKGROUND = 40 250 5 10 500 15 CENTRE FREQUENCIES (Hz) 0 AIR ON = 63.5 AIR OFF= 69 SIDE= 64.5 MEASURED dBA :- TEST SUBJECT :- VH3 600 1K 20 2K A IR ON SID E 4K 25 16K D229770 iss 1 8K DISTANCE FROM NOISE SOURCE :- 3M DATE :- 30:9:02 30 35 40 45 50 55 60 65 8.0 SOUND GRAPH SD437360 ISSUE 33 CURVES=NOISE RATING NUMBERS (NR) Page 53 BAND SOUND PRESSURE LEVEL (dB) 20 30 40 50 60 70 80 OF F 31.5 ON R AI DE SI AI R 63 O KGR BAC 125 UND BACKGROUND= 41.5 250 5 10 AIR ON 500 15 1K SIDE 20 2K AIR O 4K N 8K E SI D AI R D229771 iss1 25 DISTANCE FROM NOISE SOURCE :- 3M DATE :- 1:10:02 O N 30 35 40 45 50 55 60 65 16K F OF CENTRE FREQUENCIES (Hz) 0 AIR OFF SIDE AIR 0N= 66.5 AIR OFF= 68 SIDE= 66.5 MEASURED dBA :- TEST SUBJECT :- VH3 900 AIR SD437360 ISSUE 33 CURVES=NOISE RATING NUMBERS (NR) Page 54 SD437360 ISSUE 33 BAND SOUND PRESSURE LEVEL (dB) 20 30 40 50 60 70 80 R AI R AI 31.5 ON F OF DE SI 63 BA CK D 125 GR OU N BACKGROUND = 35.5 250 5 10 500 15 CENTRE FREQUENCIES (Hz) 0 AIR ON= 70.5 AIR OFF= 76.5 SIDE= 71 MEASURED dBA :- TEST SUBJECT :- VH3 1200 1K 20 2K 4K SIDE 8K D229772 iss1 25 DISTANCE FROM NOISE SOURCE :-3M DATE :- 1:10:02 16K 30 35 40 45 50 55 60 65 CURVES=NOISE RATING NUMBERS (NR) Page 55 SD437360 ISSUE 33 BAND SOUND PRESSURE LEVEL (dB) 20 30 40 50 60 70 80 31.5 F OF AIR ON AIR SI 63 DE BA ND 250 5 10 500 15 CENTRE FREQUENCIES (Hz) 0 SID E AIR OF F 125 C KG R O U BACKGROUND = 39 AIR ON= 76 AIR OFF= 80 SIDE= 74 MEASURED dBA :- TEST SUBJECT :- VH3 1500 1K AI R 20 ON 2K AIR OFF 4K 8K D229773 iss1 25 SI DE DISTANCE FROM NOISE SOURCE :- 3M DATE :- 1:10:02 16K 30 35 40 45 50 55 60 65 CURVES=NOISE RATING NUMBERS (NR) 9.0 FAN CURVES DDC270-270-373W-4P-1SP FAN CURVE VH3-600 230V 50Hz 10MFD 5.2A 600 5.50 2.50 400 1500 ) a P ( E R U S S E 300 R P IC T A T S 1400 STATIC PRESSURE (Pa) 1300 1200 1100 1000 900 ) M P R ( D E E P S SPEED (RPM) 500 CURRENT (AMPS) 5.00 ) S P 4.50 M A ( 4.00 T N E R 3.50 R U C 3.00 1200 200 1100 900 800 100 700 600 500 400 ) S T T A (W R E W O P POWER (WATTS) 1000 0 0 500 1000 1500 2000 2500 3000 AIRFLOW (m³/hr) Page 56 SD437360 ISSUE 33 FAN CURVE VH3-900 RPM SA(Pa) Page 57 SD437360 ISSUE 33 FAN CURVE VH3-12/1500 Pt.kp/m² Page 58 SD437360 ISSUE 33 Page 59 TEV COMP SOLENOID VALVE LPHW/BOILER IN AB A B AIR BLEED VALVE A B VALVE MOTORISED AB GATE VALVES PLATE HEAT EXCHANGER HEAT EXCHANGER COAX or COIL IN TANK AIR CONDENSER AIR BLEED VALVE VALVE MOTORISED COIL REVERSING VALVE LPHW/BOILER OUT RECEIVER / DRIER ASSY HP 400 psi AW6/9/12/1500 REFRIGERATION/WATER SCHEMATIC PROCESS PORT EVAPORATOR TEV PHIAL LP HP SERVICE SCHRADER PART OF EVAP ASSY FLEXIBLE HOSE FLEXIBLE HOSE POOL WATER IN POOL WATER OUT AIR CONDENSER 1 ROW NRV NRV LP SERVICE SCHRADER AIR BLEED VALVE AIR BLEED VALVE 10.0 REFRIGERATION DIAGRAMS SD437360 ISSUE 33 LPHW COIL Page 60 SD437360 ISSUE 33 TEV LP COMP SOLENOID VALVE HP SERVICE SCHRADER AA6/9/12/1500 REFRIGERATION SCHEMATIC PROCESS PORT EVAPORATOR TEV PHIAL LP SERVICE SCHRADER HP 400 psi RECEIVER / DRIER ASSY AIR CONDENSER 3 ROW NRV AIR CONDENSER 1 ROW PART OF EVAP ASSY TEV LP SOLENOID VALVE COMP HP 400 psi HP SERVICE SCHRADER LPHW/BOILER IN LPHW/BOILER OUT AA6/9/12/1500 REFRIGERATION + LPHW SCHEMATIC PROCESS PORT EVAPORATOR TEV PHIAL LP SERVICE SCHRADER VALVE MOTORISED AB RECEIVER / DRIER ASSY A B GATE VALVES AIR CONDENSER 3 ROW NRV FLEXIBLE HOSE FLEXIBLE HOSE AIR BLEED VALVE AIR CONDENSER 1 ROW PART OF EVAP ASSY AIR BLEED VALVE LPHW COIL Page 61 SD437360 ISSUE 33 11.0 SPARE PARTS LISTS ELECTRIC BOX ASSY CONTROL KITS FOR ‘AA’ 600/900A/BVHX(F)/1200AVHX(F) 1 NOTES 1 1 1 7 2 2 2 WIRED TO WIRING DIAGRAMS :3 PHASE 459850 SENSOR/PROBE TB 1 PHASE 459853 RE1 RE2 RE3 RE4 R1 R2 R3 6 MINS 8 6 TIMER DELAY LOOM 2 R11 022 R14 2 19 CONTACTOR FAN COMP FAN 5 COMP CAP' IF FITTED 23 IF FITTED 3 4 FAN CAP' FIT SHROUD TO 230V SIDE RCU 21 CONTROL FUSE 2.5A 20 LOOM T ERM'S 17 TO 27 TERM No 28 TO 42 (POWER KIT ) 12 13 42 ON/OFF REMO TE TERM'S TERM'S J FAN MACHINE O N H I VO LT FREE VOLT FREE G 27 COMP ENLLL MAIN FAN RUN 17 EARTH STUD 10 39 10 10 2 off 15 off ASSY No A460001 AT ISS 6 (25/01/2011). CONTROL KIT A-A VERSION ITEM NO. PART No. 1 2 3 4 5 6 7 8 10 19 20 21 23 39 SD189550 SD469250 SD416650 SD416651 SD611753 SD089550 SA329954 SD469450 SD409350 SD216550 SD035353 SD469650 SP144250 SD403551 DESCRIPTION RELAY C/O 2 POLE 16A 230V AC COIL RELAY 2POLE C/O 12V COIL TRANSFORMER 75VA SHROUD TRANSFORMER AUXILIARY CONTACT BLOCK 2 POLE DELAY TIMER 7 SEC TO 9 MIN TERMINAL BLOCK 7 WAY PLUG/SOCKET CONNECTOR D 25 W AY TERM BLOCK WDU 2.5N FUSE HOLDER FUSE 1/4 x 1 1/4 1A FUSE 2.5A ANTISURGE CLIP U NUT No. 8 SCREW 2.5 EARTH TERM WPE2.5 Page 62 QUAN UNITS 4 5 1 1 1 1 1 1 21 2 2 2 4 1 off off off off off off off off off off off off off off SD437360 ISSUE 33 ELECTRIC BOX ASSY CONTROL KITS FOR ‘AA’ / ‘AA+LPHW’ 600/900A/BVHX(F)P/1200AVHX(F)P 1 1 7 1 1 2 2 2 30 SENSOR/PROBE TB NOTES WIRED TO WIRING DIAGRAMS 3 PHASE 459850 1 PHASE 459853 RE1 RE2 RE3 RE4 R1 R2 R3 R4 8 6 TIMER DELAY LOOM 2 R11 R14 19 FAN CONTACTOR COMP FAN RCU CONTROL FUSE 2.5A 21 CONTACTOR 2 20 5 COMP CAP' IF FITTED IF FITTED 4 FIT SHROUD TO 230V SIDE FAN CAP' 3 023 LOOM TERM'S 17 TO 27 (POWER KIT) 10 11 12 13 TERM'S FAN 27 COMP RE MOTE ON/ OFF DEMAND OCC/UNOCCUPIED BOILER J REMOTE MACHI NE ON VOLT FREE I MAI N FA N RUN G H ENLL L VOLT FREE 17 TERM No 28 TO 47 47 TERM'S 67 MAINS IN 3 PHASE SHOWN PART OF POWER KIT EARTH STUD 10 39 4 off 10 10 4 off 2 off 10 20 off ASSY No A460002/04 AT ISS 6 (25/01/2011). CONTROL KIT A-A+LPHW HEATING ITEM NO. PART No. 1 2 3 4 5 6 7 8 10 19 20 21 23 30 39 SD189550 SD469250 SD416650 SD416651 SD611753 SD089550 SA329954 SD469450 SD409350 SD216550 SD035353 SD469650 SP144250 SD469350 SD403551 DESCRIPTION RELAY C/O 2 POLE 16A 230VAC COIL RELAY 2POLE C/O 12V COIL TRANSFORMER 75VA SHROUD TRANSFORMER AUXILIARY CONTACT BLOCK 2 POLE DELAY TIMER 7 SEC TO 9 MIN TERMINAL BLOCK 7 W AY PLUG/SOCKET CONNECTOR D 25 WAY TERM BLOCK WDU 2.5N FUSE HOLDER FUSE 1/4 x 1 1/4 1A FUSE 2.5A ANTISURGE CLIP U NUT No. 8 SCREW RELAY C/O 3 POLE 10A 12v COIL 2.5 EARTH TERM WPE2.5 Page 63 QUAN UNITS 4 5 1 1 1 1 2 1 30 2 2 2 4 1 1 off off off off off off off off off off off off off off off SD437360 ISSUE 33 ELECTRIC BOX ASSY CONTROL KITS FOR ‘AW’ 600/900A/B/1200AVHX(F)P 1 1 7 1 1 2 2 30 2 SENSOR/PROBE TB RE1 RE2 RE3 RE4 R1 R2 R3 R4 8 6 LOOM 6 MINS 2 30 2 DELAY TIMER 2 R8 R9 R14 R10 DELAY TIMER NOTES WIRED TO WIRING DIAGRAMS :3 PHASE 459850 2 19 43 60 MINS 12V 1 PHASE 459853 5 FAN CONTACTOR COMP FAN RCU CONTROL R13 FUSE 2.5A M3x6 P080250 21 CONTACTOR 20 3 COMP CAP' IF FITTED 4 FIT SHROUD TO FAN CAP' IF FITTED 230V SIDE 23 LOOM TERM'S 17 TO 27 7 9 11 13 17 TERM'S COMP FAN TERM'S ON/OFF REMOTE D EMAND BOILER POOL PUMP OCC/UNOCCUPIED START REMOTE MAC HINE ON VOLT FREE VOLT FREE 51 27 J ENLLL MAIN FAN RUN G H I TERM No 28 TO 51 (POWER KIT) 6 8 10 12 MAINS IN 3 PHASE SHOWN PART OF POWER KIT EARTH STUD 10 39 4 off 10 2 off 10 10 4 off 20 off ASSY No A460003 AT ISS 6 (25/01/2011). CONTROL KIT 'AW' VERSION ITEM NO. PART No. 1 2 3 4 5 6 7 8 10 19 20 21 23 30 39 43 SD189550 SD469250 SD416652 SD416651 SD611753 SD089550 SA329954 SD469450 SD409350 SD216550 SD035353 SD469650 SP144250 SD469350 SD403551 SD089551 DESCRIPTION RELAY C/O 2 POLE 16A 230VAC COIL RELAY 2POLE C/O 12V COIL TRANSFORMER 100VA SHROUD TRANSFORMER AUXILIARY CONTACT BLOCK 2 POLE DELAY TIMER 7 SEC TO 9 MIN TERMINAL BLOCK 7 W AY PLUG/SOCKET CONNECTOR D 25 WAY TERM BLOCK WDU 2.5N FUSE HOLDER FUSE 1/4 x 1 1/4 1A FUSE 2.5A ANTISURGE CLIP U NUT No. 8 SCREW RELAY C/O 3 POLE 10A 12v COIL 2.5 EARTH TERM WPE2.5 DELAY TIMER 4 to 60 mins Page 64 QUAN UNITS 4 7 1 1 1 1 1 1 36 2 2 2 4 2 1 1 off off off off off off off off off off off off off off off off SD437360 ISSUE 33 ELECTRIC BOX ASSY CONTROL KITS FOR ‘A-A’ 1200/1500BVHX(F) 1 1 1 7 1 2 2 2 NOTES WIRED TO WIRING DIAGRAM :- SENSOR/PROBE TB 3 PHASE 459859 RE1 RE2 RE3 RE4 R1 R2 R3 8 6 TIMER DELAY LOOM 2 R11 R14 2 5 CONTACTOR FAN CONTACTOR COMP RCU FUSE 21 FAN 20 CONTROL MCB 19 37 3 38 FAN CAP' IF REQD 4 FIT SHROUD TO 230V SIDE COMP CAP' IF REQD 23 LOOM TERM'S 17 TO 27 (POWER KIT) TERM No 28 TO 42 12 13 17 TERM'S FAN TERM'S COMP ON/OFF REMOTE VOLT FREE 42 J MAIN F AN RUN MACHINE ON VOLT F REE G H I EN LLL 27 EARTH STUD 10 39 10 10 2 off 4 off 15 off ASSY No A460005 AT ISS 4 (25/01/2011). CONTROL KIT AA1200/1500 3 PHASE ITEM NO. PART No. 1 2 3 4 5 6 7 8 10 19 20 21 23 38 39 SD189550 SD469250 SD416650 SD416651 SD611753 SD089550 SA329954 SD469450 SD409350 SD216550 SD035353 SD469650 SP144250 SD067250 SD403551 DESCRIPTION RELAY C/O 2 POLE 16A 230vac COIL RELAY 2POLE C/O 12V COIL TRANSFORMER 75VA SHROUD TRANSFORMER AUXILIARY CONTACT BLOCK 2 POLE DELAY TIMER 7 SEC TO 9 MIN TERMINAL BLOCK 7 W AY PLUG/SOCKET CONNECTOR D 25 WAY TERM BLOCK WDU 2.5N FUSE HOLDER FUSE 1/4 x 1 1/4 1A FUSE 2.5A ANTISURGE CLIP U NUT No. 8 SCREW RELAY BASE & CLIP 11 PIN 2.5 EARTH TERM WPE2.5 Page 65 QUAN UNITS 4 5 1 1 1 1 1 1 21 2 2 2 4 1 1 off off off off off off off off off off off off off off off SD437360 ISSUE 33 ELECTRIC BOX ASSY CONTROL KITS FOR ‘A-A’ 1200/1500BVHX(F)P 1 1 1 7 1 NOTES 2 2 30 2 SENSOR/PROBE TB WIRED TO WIRING DIAGRAM :3 PHASE 459858 RE1 RE2 RE3 RE4 R1 R2 R3 R4 8 06 DELAY TIMER LOOM 2 R11 R14 2 CONTACTOR FAN CONTACTOR COMP FAN 21 RCU FUSE 20 CONTROL MCB 19 5 40 3 41 FAN CAP' IF REQD 4 FIT SHROUD TO 230V SIDE 23 LOOM TERM'S 17 TO 27 67 10 11 12 13 TERM No 28 TO 47 (POW ER KIT) 10 4 off 39 10 2 off FAN 47 TERM'S COMP 27 TERM'S REMOTE ON/OFF BOILER DEMAND J VOLT FREE MACHINE ON VOLT FREE MAIN F AN RUN G H I ENLL L REMOTE OCC/UNOCCUPIED 17 10 10 4 off 20 off ASSY No A460006 AT ISS 4 (25/01/2011). CONTROL KIT AA1200/1500 + RES HEATERS 3 PHASE ITEM NO. PART No. 1 2 3 4 5 6 7 8 10 19 20 21 23 30 39 41 SD189550 SD469250 SD416650 SD416651 SD611753 SD089550 SA329954 SD469450 SD409350 SD216550 SD035353 SD469650 SP144250 SD469350 SD403551 SD067250 DESCRIPTION RELAY C/O 2 POLE 16A 230VAC COIL RELAY 2POLE C/O 12V COIL TRANSFORMER 75VA SHROUD TRANSFORMER AUXILIARY CONTACT BLOCK 2 POLE DELAY TIMER 7 SEC TO 9 MIN TERMINAL BLOCK 7 WAY PLUG/SOCKET CONNECTOR D 25 WAY TERM BLOCK WDU 2.5N FUSE HOLDER FUSE 1/4 x 1 1/4 1A FUSE 2.5A ANTISURGE CLIP U NUT No. 8 SCREW RELAY C/O 3 POLE 10A 12V COIL 2.5 EARTH TERM WPE2.5 RELAY BASE & CLIP 11 PIN Page 66 QUAN UNITS 4 5 1 1 1 1 2 1 30 2 2 2 4 1 1 1 off off off off off off off off off off off off off off off off SD437360 ISSUE 33 ELECTRIC BOX ASSY CONTROL KITS FOR ‘AW’ 1200/1500 THREE PHASE ONLY 1 1 1 7 1 2 2 30 2 NOTES WIRED TO WIRING DIAGRAM :- SENSOR/PROBE TB 3 PHASE 459857 RE1 8 RE2 RE3 RE4 R1 R2 R3 R4 LOOM 6 6 MINS 30 2 2 DELAY TIMER 2 43 60 MINS 12V R9 R10 R14 DELAY TIMER R8 2 FAN CONTACTOR COMP FAN R13 RCU 21 CONTROL MCB FUSE 2.5A 20 5 CONTACTOR 19 21 45 3 46 FAN CAP' IF REQD 4 FIT SHROUD TO 230V SIDE 23 LOOM 7 9 11 6 13 8 10 12 TERM'S 17 TO 27 (POWER KIT) 17 51 FAN TERM'S COMP TERM'S ON /OFF REMOTE OC C/ UNO CCUPIED DEM AND BOILER P OOL P UMP ST ART REMOTE MACHINE ON VOLT FRE E VOLT FRE E 27 J M AIN FAN RUN G H I EN LLL TERM No 28 TO 51 EARTH STUD 010 4 off 10 2 off 10 10 4 off 20 off ASSY No A460007 AT ISS 4 (25/01/2011). CONTROL KIT AW1200/1500 3 PHASE ITEM NO. PART No. 1 2 3 4 5 6 7 8 10 19 20 21 23 30 39 43 46 SD189550 SD469250 SD416652 SD416651 SD611753 SD089550 SA329954 SD469450 SD409350 SD216550 SD035353 SD469650 SP144250 SD469350 SD403551 SD089551 SD067250 DESCRIPTION RELAY C/O 2 POLE 16A 230VAC COIL RELAY 2POLE C/O 12V COIL TRANSFORMER 100VA SHROUD TRANSFORMER AUXILIARY CONTACT BLOCK 2 POLE DELAY TIMER 7 SEC TO 9 MIN TERMINAL BLOCK 7 WAY PLUG/SOCKET CONNECTOR D 25 WAY TERM BLOCK WDU 2.5N FUSE HOLDER FUSE 1/4 x 1 1/4 1A FUSE 2.5A ANTISURGE CLIP U NUT No. 8 SCREW RELAY C/O 3 POLE 10A 12V COIL 2.5 EARTH TERM WPE2.5 DELAY TIMER 4 to 60 mins RELAY BASE & CLIP 11 PIN Page 67 QUAN UNITS 4 7 1 1 1 1 1 1 36 2 2 2 4 2 1 1 1 off off off off off off off off off off off off off off off off off SD437360 ISSUE 33 ELECTRIC BOX ASSY CONTROL KITS FOR ‘AA’ +AIR HEATING’ 1200/1500 THREE PHASE ONLY 1 NOTES 1 1 7 1 2 2 2 30 WIRED TO WIRING DIAGRAM :3 PHASE 459858 SENSOR/PROBE TB RE1 RE2 RE3 RE4 R1 R2 R3 R4 8 6 TIMER DELAY LOOM 2 R11 R14 2 5 CONTACTOR COMP FAN RCU 21 CONTROL MCB FUSE 2.5A 20 FAN CONTACTOR 19 41 3 FAN CAP' IF REQD 4 FIT SHROUD TO 230V SIDE 23 LOOM TERM'S 17 TO 27 67 10 11 12 13 47 FAN TERM'S COMP TERM'S ON/OFF REMOTE OCC/UNOCCUPIED BOILER DEMAND 10 27 J REMOTE 39 VOLT FREE VOLT FREE MACHINE ON I MAIN FAN RUN G H EN LLL TERM No 28 TO 47 (POWER KIT) 17 EARTH STUD 4 off 10 2 off 10 4 off 10 20 off ASSY No A460008 AT ISS 4 (25/01/2011). CONTROL KIT AA + AIR HEATING AA1200/1500 3 PHASE ITEM NO. PART No. 1 2 3 4 5 6 7 8 10 19 20 21 23 30 41 45 SD189550 SD469250 SD416650 SD416651 SD611753 SD089550 SA329954 SD469450 SD409350 SD216550 SD035353 SD469650 SP144250 SD469350 SD067250 SD403551 DESCRIPTION RELAY C/O 2 POLE 16A 230vac COIL RELAY 2POLE C/O 12V COIL TRANSFORMER 75VA SHROUD TRANSFORMER AUXILIARY CONTACT BLOCK 2 POLE DELAY TIMER 7 SEC TO 9 MIN TERMINAL BLOCK 7 WAY PLUG/SOCKET CONNECTOR D 25 WAY TERM BLOCK WDU 2.5N FUSE HOLDER FUSE 1/4 x 1 1/4 1A FUSE 2.5A ANTISURGE CLIP U NUT No. 8 SCREW RELAY C/O 3 POLE 10A 12v COIL RELAY BASE & CLIP 11 PIN 2.5 EARTH TERM WPE2.5 Page 68 QUAN UNITS 4 5 1 1 1 1 2 1 30 2 2 2 4 1 1 1 off off off off off off off off off off off off off off off off SD437360 ISSUE 33 11.0 SPARES PARTS LISTS (cont.) ELECTRIC BOX ASSY POWER KITS FOR 6/9/1200A WIRED TO WIRING DIAGRAM:D459853 FOR AW VERSION D459854 FOR AA+AIR HEATING D459855 FOR AA VERSION LOOM 7 6 8 4 5 28 2 A2 COMP CONTACTOR CONTACTOR FAN FAN COMP CONTROL A1 1 3 5 4 6 13 NO NO 14 COMP CAP' 15 FAN CAP' 14 13 LOOM 9 10 EARTH 17 18 19 20 21 22 23 24 25 26 27 EARTH 11 N L 9 12 9 ASSY No A460010 AT ISS 10 (25/07/2012). POWER KIT 600 SINGLE PHASE ITEM NO. PART No. 4 5 6 7 8 9 10 11 12 13 14 15 28 SD612052 SD392551 SD316550 SD316553 SD316557 SD403550 SD409550 SD403851 SD409350 SD022550 SD033151 SD159850 SD403950 DESCRIPTION CONTACTOR 18A 3+1N/O AUX CONTACTOR CIRCUIT BREAKER MINIATURE 2A CIRCUIT BREAKER MINIATURE 10A MINIATURE CIRC BREAKER 16A TERM EARTH WPE6 8mm TERMINAL BLOCK WDU10 TERMINAL BLOCK BARRIER WAP 16-35 TERM BLOCK WDU 2.5N CAPACITOR 35μF 440V 50/60Hz CAPACITOR 10μF +/-5% 450V PILOT LIGHT RED 240V END BRACKET EW35 (8.5) QUAN UNITS 1 1 1 1 1 3 2 2 9 1 1 1 1 off off off off off off off off off off off off off NOTE FOR POWER KITS W HEN FRESH AIR BOX IS FITTED: DROP ITEM NO. PART No. DESCRIPTION QUAN 6 SD316550 CIRCUIT BREAKER MINIATURE 2A 1 UNITS off FIT ITEM NO. PART No. 6 SD316551 UNITS off DESCRIPTION CIRCUIT BREAKER MINIATURE 4 A Page 69 QUAN 1 SD437360 ISSUE 33 WIRED TO WIRING DIAGRAM:D459853 FOR AW VERSION D459854 FOR AA+AIR HEATING D459855 FOR AA VERSION LOOM 7 6 8 4 5 32 CONTACTOR FAN FAN COMP CONTROL A1 A2 1 3 5 2 4 6 13 NO FAN CAP' 14 14 13 COMP CAP' 15 LOOM 9 10 EARTH EARTH 17 18 1 9 20 21 22 23 24 25 2 6 27 11 N L 9 12 FAN LO OM P/SW T LOOM COMP LOOM 9 ASSY No A460012 AT ISS 9 (02/09/2011). POWER KIT 900 SINGLE PHASE ITEM NO. PART No. 4 5 6 7 8 9 10 11 12 13 14 15 28 SD612053 SD392551 SD316550 SD316553 SD316554 SD403550 SD409550 SD403851 SD409350 SD157850 SD111850 SD159850 SD403950 DESCRIPTION CONTACTOR 25A 3+1N/O AUX CONTACTOR CIRCUIT BREAKER MINIATURE 2A CIRCUIT BREAKER MINIATURE 10A CIRCUIT BREAKER 20A TERM EARTH WPE6 8mm TERMINAL BLOCK WDU10 TERMINAL BLOCK BARRIER WAP 16-35 TERM BLOCK WDU 2.5N CAPACITOR FOR COMP 40µF +/- 10% 370V CAPACITOR 20µF +/- 10% 440V PILOT LIGHT RED 240V END BRACKET EW35 (8.5) QUAN UNITS 1 1 1 1 1 3 2 2 9 1 1 1 1 off off off off off off off off off off off off off NOTE FOR POWER KITS WHEN FRESH AIR BOX IS FITTED: DROP ITEM NO. PART No. DESCRIPTION QUAN 6 SD316550 CIRCUIT BREAKER MINIATURE 2A 1 UNITS off FIT ITEM NO. PART No. 6 SD316551 UNITS off DESCRIPTION CIRCUIT BREAKER MINIATURE 4 A Page 70 QUAN 1 SD437360 ISSUE 33 WIRED TO WIRING DIAGRAM:D459853 FOR AW VERSION D459854 FOR AA+AIR HEATING D459855 FOR AA VERSION 7 6 5 8 4 LOO M 28 CONTACTOR COMP FAN CONTROL FAN A1 A2 1 3 5 2 4 6 13 NO NO 14 13 COMP CAP' 15 FAN CAP' 35 LOOM 310.00 9 10 N L EARTH EARTH 11 17 18 1 9 2 0 2 1 22 23 2 4 25 26 27 9 9 OM P/SWT LO M FAN LOO COMP LOOM 12 ASSY No A460014 AT ISS 13 (18/07/2012). POWER KIT 1200 SINGLE PHASE ITEM NO. PART No. 4 5 6 7 8 9 10 11 12 13 15 28 35 SD612053 SD392551 SD316550 SD316554 SD316556 SD403550 SD409550 SD403851 SD409350 SD486650 SD159850 SD403950 SD111850 DESCRIPTION QUAN UNITS 1 1 1 1 1 3 2 2 9 1 1 1 1 off off off off off off off off off off off off off CONTACTOR 25A 3+1N/O AUX CONTACTOR CIRCUIT BREAKER MINIATURE 2A CIRCUIT BREAKER MINIATURE 20A CIRCUIT BREAKER MINIATURE 32A TERM EARTH WPE6 8mm TERMINAL BLOCK WDU10 TERMINAL BLOCK BARRIER WAP 16-35 TERM BLOCK WDU 2.5N RUN CAP 60μF 470V PILOT LIGHT RED 240V END BRACKET EW35 (8.5) CAPACITOR 20µF ± 10% 400V NOTE FOR POWER KITS WHEN FRESH AIR BOX IS FITTED: DROP ITEM NO. PART No. 6 SD316550 DESCRIPTION CIRCUIT BREAKER MINIATURE 2A QUAN 1 UNITS off FIT ITEM NO. PART No. 6 SD316551 DESCRIPTION CIRCUIT BREAKER MINIATURE 4 A QUAN 1 UNITS off Page 71 SD437360 ISSUE 33 ELECTRIC BOX ASSY POWER KITS FOR 600/900B WIRED TO WIRING DIAGRAM:D459853 FOR AW VERSION D459854 FOR AA+AIR HEATING D459855 FOR AA VERSION LOOM 7 6 8 4 5 28 FAN CONTACTOR COMP FAN CONTROL A1 A2 1 3 5 2 4 6 13 NO NO 14 FAN CAP' 14 15 LOOM 9 10 11 EA RTH EA RTH 17 18 19 20 21 22 23 24 25 26 27 N LL L 9 12 009 ASSY No A460011 AT ISS 9 (26/07/2012). POWER KIT 600 THREE PHASE ITEM NO. PART No. 4 5 6 7 8 9 10 11 12 14 15 28 SD612050 SD392551 SD316550 SD316553 SD611551 SD403550 SD409550 SD403850 SD409350 SD033151 SD159850 SD403950 DESCRIPTION QUAN UNITS 1 1 1 1 1 3 4 4 9 1 1 1 off off off off off off off off off off off off CONTACTOR 9A 3+1 N/O AUX CONTACTOR CIRCUIT BREAKER MINIATURE 2A CIRCUIT BREAKER MINIATURE 10A MOTOR STARTER O/LOAD 2.5-4.0A TERM EARTH W PE6 8mm TERMINAL BLOCK WDU10 TERMINAL BLOCK BARRIER WAP 16-35 TERM BLOCK WDU 2.5N CAPACITOR 10μF +/-5% 450V PILOT LIGHT RED 240V END BRACKET EW35 (8.5) NOTE FOR POWER KITS WHEN FRESH AIR BOX IS FITTED: DROP ITEM NO. PART No. 6 SD316550 DESCRIPTION CIRCUIT BREAKER MINIATURE 2A QUAN 1 UNITS off FIT ITEM NO. PART No. 6 SD316551 DESCRIPTION CIRCUIT BREAKER MINIATURE 4 A QUAN 1 UNITS off Page 72 SD437360 ISSUE 33 WIRED TO WIRING DIAGRAM:D459853 FOR AW VERSION D459854 FOR AA+AIR HEATING D459855 FOR AA VERSION LOOM 7 6 8 4 5 28 FAN CONTACTOR COMP FAN CONTROL A1 A2 1 3 5 2 4 6 13 NO NO 14 FAN CAP' 14 15 LOOM 9 10 11 EA RTH EA RTH 17 18 19 20 21 22 23 24 25 26 27 N LLL 9 12 009 ASSY No A460013 AT ISS 9 (02/09/2011). POWER KIT 900 THREE PHASE ITEM NO. PART No. 4 5 6 7 8 9 10 11 12 14 15 28 SD612050 SD392551 SD316550 SD316553 SD611552 SD403550 SD409550 SD403850 SD409350 SD111850 SD159850 SD403950 DESCRIPTION CONTACTOR 9A 3+1 N/O AUX CONTACTOR CIRCUIT BREAKER MINIATURE 2A CIRCUIT BREAKER MINIATURE 10A MOTOR STARTER OVERLOAD 4.0 - 6.3A TERM EARTH WPE6 8mm TERMINAL BLOCK WDU10 TERMINAL BLOCK BARRIER W AP 16-35 TERM BLOCK WDU 2.5N CAPACITOR 20μF +/-10% 440V PILOT LIGHT RED 240V END BRACKET EW35 (8.5) QUAN UNITS 1 1 1 1 1 3 4 4 9 1 1 1 off off off off off off off off off off off off NOTE FOR POWER KITS W HEN FRESH AIR BOX IS FITTED: DROP ITEM NO. PART No. DESCRIPTION QUAN 6 SD316550 CIRCUIT BREAKER MINIATURE 2A 1 UNITS off FIT ITEM NO. PART No. 6 SD316551 UNITS off DESCRIPTION CIRCUIT BREAKER MINIATURE 4 A Page 73 QUAN 1 SD437360 ISSUE 33 ELECTRIC BOX ASSY POWER KITS FOR 1500B WIRED TO WIRING DIAGRAM:D459853 FOR AW VERSION D459854 FOR AA+AIR HEATING D459855 FOR AA VERSION 31 7 8 5 4 LOOM 260.00 29 6 CONTACTOR FAN CONTROL COMP FAN A1 1 A2 3 5 13 NO NO 2 4 6 14 SUPPLIED LOOSE 32 FAN CAP' 13 LOOM 310.00 9 DIN RAIL D221864 10 N LL L EARTH EARTH 11 17 18 19 20 21 22 23 24 25 26 27 9 9 12 ASSY No A460015 AT ISS 15 (26/07/2012). POWER KIT 1200 THREE PHASE ITEM NO. PART No. 4 5 6 7 8 9 10 11 12 13 29 31 32 SD612051 SD392551 SD448750 SD611550 SD611553 SD403550 SD409550 SD403850 SD409350 SD159850 SD403950 SD316554 SD111850 DESCRIPTION CONTACTOR 12A 3+1 N/O AUX CONTACTOR PTC SENSOR LEAD (TECNOLOGIC) MOTOR STARTER O/LOAD 1.6-2.5A MOTOR STARTER O/LOAD 6.5 - 10.0 A TERM EARTH WPE6 8mm TERMINAL BLOCK WDU10 TERMINAL BLOCK BARRIER W AP 2.5 TERM BLOCK WDU 2.5N PILOT LIGHT RED 240v END BRACKET EW35 (8.5) CIRCUIT BREAKER MINIATURE 20A RUN CAPACITOR 20μF 440V Page 74 QUAN UNITS 1 1 1 1 1 3 4 4 9 1 1 1 1 off off off off off off off off off off off off off SD437360 ISSUE 33 WIRED TO WIRING DIAGRAM:D459853 FOR AW VERSION D459854 FOR AA+AIR HEATING D459855 FOR AA VERSION 8 7 6 5 4 LOOM 29 30 CONTACTOR FAN FAN CONTROL COMP A1 1 A2 3 5 13 NO NO 2 4 6 14 SUPPLIED LOOSE 13 LOOM 9 DIN RAIL D221864 10 11 EARTH EARTH 17 18 19 20 21 22 23 24 25 26 27 N LLL 9 9 12 ASSY No A460016 AT ISS 9 (25/01/2011). POWER KIT 1500 THREE PHASE ITEM NO. PART No. 4 5 6 7 8 9 10 11 12 13 29 30 SD612052 SD392551 SD611550 SD611551 SD611555 SD403550 SD409550 SD403850 SD409350 SD159850 SD403950 SD448750 DESCRIPTION CONTACTOR 18A 3+1N/O AUX CONTACTOR MOTOR STARTER O/LOAD 1.6-2.5A MOTOR STARTER O/LOAD 2.5-4.0A 3P MOTOR STARTER O/LOAD 12-18A 3PH TERM EARTH WPE6 8mm TERMINAL BLOCK WDU10 TERMINAL BLOCK BARRIER WAP 2.5 TERM BLOCK WDU 2.5N PILOT LIGHT RED 240v END BRACKET EW35 (8.5) PTC SENSOR LEAD (TECNOLOGIC) Page 75 QUAN UNITS 1 1 1 1 1 3 4 4 9 1 1 1 off off off off off off off off off off off off SD437360 ISSUE 33 12.0 CONTROL PANELS STANDARD CONTROL PANEL MODULE NOTES CAN BE FITTED EITHER END DEPENDING ON POSN OF 25 CONNECTOR WIRED TO WIRING DIAGRAM D460850 15 8 1 9 10 10 3 12 4 5 % RH °C 11 °C MAX AUTO HUMIDITY MIN AIR TEMP = AU TO WATER TEMP 4 STAGE = = AUTO 14 22 13 7 14 6 14 ALTERNATIVE POSN'S FOR 25 WAY D CONNECTOR ACHIEVED BY TURNING REAR PANEL AROUND ASSY No A470001 AT ISS 2 (21/05/2009). CONTROL PANEL AW MACHINES ITEM NO. PART No. 1 2 3 4 5 6 8 9 10 11 12 13 14 15 22 SD418450 SD469801 SD432451 SD432555 SD432552 SD469451 SD318650 SD316750 SD469950 SD151554 SD470352 SD470351 SD470350 SD163352 SD434051 DESCRIPTION REAR PANEL FRONT PANEL THERMOSTAT HUMIDITY AIR STAT (4 STAGE) THERMOSTAT WATER CONNECTOR D 25WAY MALE SWITCH ROCKER 2 POLE SWITCH 2 POLE 3 POSN C/O SWITCH ROCKER SPST TIME CLOCK 12V AC PILOT LIGHT YELLOW 12VAC PILOT LIGHT GREEN 12VAC PILOT LIGHT RED 12VAC TERMINAL BLOCK CABLE ASSY D25 MALE/FEMALE Page 76 QUAN UNITS 1 1 1 1 1 1 1 1 2 1 2 1 4 1 1 off off off off off off off off off off off off off off off SD437360 ISSUE 33 ASSY No A470002 AT ISS 1 (15/06/2005). CONTROL PANEL AA+LPHW MACHINES ITEM NO. PART No. DESCRIPTION 1 2 3 4 6 8 9 11 12 13 14 15 22 SD418450 REAR PANEL SD469803 FRONT PANEL SD432451 THERMOSTAT HUMIDITY SD432555 AIR STAT (4 STAGE) SD469451 CONNECTOR D 25WAY MALE SD318650 SWITCH ROCKER 2 POLE SD316750 SWITCH 2 POLE 3 POSN C/O SD151554 TIME CLOCK 12v AC SD470352 PILOT LIGHT YELLOW 12Vac SD470351 PILOT LIGHT GREEN 12Vac SD470350 PILOT LIGHT RED 12Vac SD163352 TERMINAL BLOCK SD434051 CABLE ASSY D25 MALE/FEMALE QUAN UNITS 1 1 1 1 1 1 1 1 2 1 3 1 1 off off off off off off off off off off off off off ASSY No A470003 AT ISS 1 (15/06/2005). CONTROL PANEL AA MACHINES ITEM NO. PART No. DESCRIPTION 1 2 3 4 6 8 9 12 13 14 15 22 SD418450 REAR PANEL SD469802 FRONT PANEL SD432451 THERMOSTAT HUMIDITY SD432551 THERMOSTAT AIR SD469451 CONNECTOR D 25WAY MALE SD318650 SWITCH ROCKER 2 POLE SD316750 SWITCH 2 POLE 3 POSN C/O SD470352 PILOT LIGHT YELLOW 12Vac SD470351 PILOT LIGHT GREEN 12Vac SD470350 PILOT LIGHT RED 12Vac SD163352 TERMINAL BLOCK SD434051 CABLE ASSY D25 MALE/FEMALE Page 77 QUAN UNITS 1 1 1 1 1 1 1 2 1 3 1 1 off off off off off off off off off off off off SD437360 ISSUE 33 12.1 CONTROL PANEL REMOTE (OPTIONAL) RED 4 11 2 34 31 6 30 31 x 29 MAX AUTO MIN % RH 7 9 = AUTO ºC = = 8 AUTO AUTO ºC 34 RED 24 34 34 RED RED 35 12 32 32 YELLOW YELLOW 40 33 10 42 GREEN 13 x PART SECTION X-X ASSY No A478001 AT ISS 4 (21/05/2009). REMOTE CONSOLE 'AW' VERSION ITEM NO. PART No. 2 4 6 7 8 9 10 11 12 13 24 29 30 31 32 33 34 35 40 42 SD477401 SD310552 SA432451 SA432555 SA432552 SD151554 SD260351 SD324350 SD317150 SD317250 SD434052 SD318650 SD316750 SD469950 SD470352 SD470351 SD470350 SD163352 SD448750 SA329954 DESCRIPTION DISPLAY PANEL WINDOW HUMIDITY STAT, TECHNOLOGIC AIR STAT CALIBRATED THERMOSTAT WATER TIME CLOCK 12V AC HUMIDITY SENSOR ADJUSTABLE HINGE MAGNETIC CATCH STEEL CATCH STRIKE 25 WAY D CONNECTOR 10M SWITCH ROCKER 2 POLE SWITCH 2 POLE 3 POSN C/O SWITCH ROCKER SPST PILOT LIGHT YELLOW 12VAC PILOT LIGHT GREEN 12VAC PILOT LIGHT RED 12VAC TERMINAL BLOCK PTC SENSOR LEAD (TECNOLOGIC) TERMINAL BLOCK 7 W AY PLUG/SOCKET Page 78 QUAN UNITS 1 1 1 1 1 1 1 2 1 1 1 1 1 2 2 1 4 1 1 1 off off off off off off off off off off off off off off off off off off off off SD437360 ISSUE 33 RED 4 11 33 2 30 X 29 MAX 6 AUTO MIN % RH 9 7 = AUTO ºC = = AUTO 33 RED 24 33 34 12 31 31 10 38 32 YELLOW YELLOW 40 GREEN 13 RED PART SECTION X-X X ASSY No A478002 AT ISS 4 (25/01/2011). REMOTE CONSOLE 'AA+LPHW VERSION ITEM NO. PART No. 2 4 6 7 9 10 11 12 13 24 29 30 31 32 33 34 38 40 SD477402 SD310552 SA432451 SA432555 SD151554 SD260351 SD324350 SD317150 SD317250 SD434052 SD318650 SD316750 SD470352 SD470351 SD470350 SD163352 SD448750 SA329954 DESCRIPTION DISPLAY PANEL WINDOW HUMIDITY STAT, TECHNOLOGIC AIR STAT CALIBRATED TIME CLOCK 12v AC HUMIDITY SENSOR ADJUSTABLE HINGE MAGNETIC CATCH STEEL CATCH STRIKE 25 WAY D CONNECTOR 10M SWITCH ROCKER 2 POLE SWITCH 2 POLE 3 POSN C/O PILOT LIGHT YELLOW 12Vac PILOT LIGHT GREEN 12Vac PILOT LIGHT RED 12Vac TERMINAL BLOCK PTC SENSOR LEAD (TECNOLOGIC) TERMINAL BLOCK 7 W AY PLUG/SOCKET Page 79 QUAN UNITS 1 1 1 1 1 1 2 1 1 1 1 1 2 1 3 1 1 1 off off off off off off off off off off off off off off off off off off SD437360 ISSUE 33 RED 4 11 33 2 30 X 29 MAX 6 AUTO MIN % RH 9 7 = AUTO ºC = = AUTO 33 RED 24 33 34 12 31 31 10 38 32 YELLOW YELLOW 40 GREEN 13 RED PART SECTION X-X X ASSY No A478003 AT ISS 5 (26/01/2011). REMOTE CONSOLE 'AA' VERSION ITEM NO. PART No. 2 4 6 7 9 10 11 12 13 24 29 30 31 32 33 34 38 40 SD477402 SD310552 SA432451 SA432551 SD456350 SD260351 SD324350 SD317150 SD317250 SD434052 SD318650 SD316750 SD470352 SD470351 SD470350 SD163352 SD448750 SA329954 DESCRIPTION DISPLAY PANEL WINDOW HUMIDITY STAT, TECHNOLOGIC THERMOSTAT AIR BLANKING PLATE HUMIDITY SENSOR ADJUSTABLE HINGE MAGNETIC CATCH STEEL CATCH STRIKE 25 WAY D CONNECTOR 10M SWITCH ROCKER 2 POLE SWITCH 2 POLE 3 POSN C/O PILOT LIGHT YELLOW 12Vac PILOT LIGHT GREEN 12Vac PILOT LIGHT RED 12Vac TERMINAL BLOCK PTC SENSOR LEAD (TECNOLOGIC) TERMINAL BLOCK 7 WAY PLUG/SOCKET Page 80 QUAN UNITS 1 1 1 1 1 1 2 1 1 1 1 1 2 1 3 1 1 1 off off off off off off off off off off off off off off off off off off SD437360 ISSUE 33 Page 81 LP HP 22 23 1 2 3 D44 3651 ISS 1 4 5 6 52 7 8 9 10 12 FRIDGE BOX ASSY AA600/900A/BVHXF 11 55 SHOWING PRESSURE SWITCH BKT ASSY 26 OTHER SIDE 20 47 12 33 10 6 5 25 CAN BE IN FRESH AIR BOX, (IF FITTED) 11 48 AIR TEMP PROBE 49 2 NOTE DIRECTION OF ARROW 51 9 8 16 42 21 19 18 13.0 FRIDGE BOX ASSEMBLIES 13.1 MAIN FRIDGE COMPONENTS ALL MACHINES SD437360 ISSUE 33 ASSY No A436008 AT ISS 5 (21/03/2007). FRIDGE BOX ASSY AA600A/BXF ITEM NO. PART No. 2 5 6 8 9 10 11 12 12a 16 18 19 20 21 22 23 25 26 33 42 47 48 49 51 52 55 SD416001 SD416550 SD416551 SD416701 SD416850 SD416950 SD418250 SD286252 SD132856 SD310153 SD166250 SD166550 SD149650 SD084550 SD384550 SD101350 SD086851 SA145802 SD066350 SD197150 SP182554 SD260351 SD448750 SD111050 SD072858 SD470750 DESCRIPTION EVAPORATOR PANEL BRACKET PANEL BRACKET DRIPTRAY DRIPTRAY SUPPORT BKT COMPRESSOR CHANNEL SENSOR BRACKET COMPRESSOR, H79B22UABKA SINGLE PHASE COMPRESSOR, H79B22UDBEA THREE PHASE FILTER PANEL SOLENOID VALVE 3/8 SOLENOID COIL 230V 50HZ RECEIVER/DRIER NRV 3/8 L P SWITCH MANUAL RESET HP SWITCH (400psi) TEV INE 2GA STAT/TIMER FOR DEFROST SCHRADER VALVE FILTER 24 X 24 X 2 REFRIGERANT R407c HUMIDITY SENSOR TEMPERATURE PROBE PIPE FLEXIBLE CLEAR PVC 16 BORE TERMINAL BLOCK 12 WAY (16A) COVER FOR TB QUAN UNITS 1 1 1 1 1 2 1 1 1 2 1 1 1 1 1 1 1 1 2 1 1.8 1 1 0.4 1 1 off off off off off off off off off off off off off off off off off off off off kg off off m off off ASSY No A436010 AT ISS 1 (21/03/2007). FRIDGE BOX ASSY AA900A/BXF ITEM NO. PART No. 2 5 6 8 9 10 11 12 12a 16 18 19 20 21 22 23 25 26 33 42 47 48 49 51 52 55 SD416001 SD416550 SD416551 SD416701 SD416850 SD416950 SD418250 SD132956 SD133055 SD310153 SD166250 SD166550 SD149650 SD084550 SD384550 SD101350 SD086951 SA145802 SD066350 SD197150 SP182554 SD260351 SD448750 SD111050 SD072858 SD470750 DESCRIPTION EVAPORATOR PANEL BRACKET PANEL BRACKET DRIPTRAY DRIPTRAY SUPPORT BKT COMPRESSOR CHANNEL SENSOR BRACKET COMPRESSOR H79B32UABKA SINGLE PHASE COMPRESSOR H79B32UDBEA THREE PHASE FILTER PANEL SOLENOID VALVE 3/8 SOLENOID COIL 230V 50HZ RECEIVER/DRIER NRV 3/8 L P SWITCH MANUAL RESET HP SWITCH (400psi) TEV BBINE-3-GA-B10 STAT/TIMER FOR DEFROST SCHRADER VALVE FILTER 24 X 24 X 2 REFRIGERANT R407c HUMIDITY SENSOR TEMPERATURE PROBE PIPE FLEXIBLE CLEAR PVC 16 BORE TERMINAL BLOCK 12 WAY (16A) COVER FOR TB Page 82 QUAN UNITS 1 1 1 1 1 2 1 1 1 2 1 1 1 1 1 1 1 1 2 1 1.85 1 1 0.4 1 1 off off off off off off off off off off off off off off off off off off off off kg off off m off off SD437360 ISSUE 33 Page 83 SD437360 ISSUE 33 LP HP 22 23 1 2 D44 365 1 I SS 1 3 4 5 6 52 7 8 9 10 12 FRIDGE BOX ASSY AA1200/1500A/BVHXF 11 55 SHOWING PRESSURE SWITCH BKT ASSY 26 20 OTHER SIDE FITTED TO 1200 MACHINES 50 47 12 10 33 6 5 25 CAN BE IN FRESH AIR BOX, (IF FITTED) 11 48 AIR TEMP PROBE 49 2 NOTE DIRECTION OF ARROW 51 9 8 16 42 21 19 18 ASSY No A436012 AT ISS 5 (21/03/2007). FRIDGE BOX AA1200A/BXF ITEM NO. PART No. 2 5 6 8 9 10 11 12 12a 16 18 19 20 21 22 23 25 26 33 42 47 48 49 50 51 52 55 SD416002 SD416552 SD416553 SD416702 SD416851 SD416952 SD418250 SD500953 SD500952 SD310155 SD166250 SD166550 SD149650 SD084550 SD384550 SD101350 SD087151 SA145802 SD066350 SD197152 SP182554 SD260351 SD448750 SD404254 SD111050 SD072858 SD470750 DESCRIPTION EVAPORATOR PANEL BRACKET PANEL BRACKET DRIPTRAY DRIPTRAY SUPPORT BKT COMPRESSOR CHANNEL SENSOR BRACKET COMPRESSOR C-SBN261H5A 1~230V50Hz SANYO COMPRESSOR C-SBN263H8A 3~400V50Hz SANYO FILTER PANEL SOLENOID VALVE 3/8 SOLENOID COIL 230V 50HZ RECEIVER/DRIER NRV 3/8 L P SW ITCH MANUAL RESET HP SW ITCH (400psi) TEV INE5GA STAT/TIMER FOR DEFROST SCHRADER VALVE AIR FILTER DISPOSABLE TYPE REFRIGERANT R407c HUMIDITY SENSOR TEMPERATURE PROBE CRANKCASE HEATER PIPE FLEXIBLE CLEAR PVC 16 BORE TERMINAL BLOCK 12 W AY (16A) COVER FOR TB QUAN UNITS 1 1 1 1 1 2 1 1 1 2 1 1 1 1 1 1 1 1 2 1 2.7 1 1 1 0.55 1 1 off off off off off off off off off off off off off off off off off off off off kg off off off m off off ASSY No A436014 AT ISS 11 (26/07/2012). FRIDGE BOX ASSY AA1500BXF ITEM NO. PART No. 2 5 6 8 9 10 11 12 16 18 19 20 21 22 23 25 26 33 42 47 48 49 51 52 55 SD416002 SD416552 SD416553 SD416702 SD416851 SD416952 SD418250 SD500851 SD310155 SD166250 SD166550 SD149650 SD084550 SD384550 SD101350 SD084350 SA145802 SD066350 SD197152 SP182554 SD260351 SD448750 SD111050 SD072858 SD470750 DESCRIPTION EVAPORATOR PANEL BRACKET PANEL BRACKET DRIPTRAY DRIPTRAY SUPPORT BKT COMPRESSOR CHANNEL SENSOR BRACKET COMPRESSOR C-SBN373H8A FILTER PANEL SOLENOID VALVE 3/8 SOLENOID COIL 230V 50HZ RECEIVER/DRIER NRV 3/8 L P SWITCH MANUAL RESET HP SWITCH (400psi) VALVE TEV (SVE8VGA) STAT/TIMER FOR DEFROST SCHRADER VALVE AIR FILTER DISPOSABLE TYPE REFRIGERANT R407c HUMIDITY SENSOR TEMPERATURE PROBE PIPE FLEXIBLE CLEAR PVC 16 BORE TERMINAL BLOCK 12 WAY (16A) COVER FOR TB Page 84 QUAN UNITS 1 1 1 1 1 2 1 1 2 1 1 1 1 1 1 1 1 2 1 2.65 1 1 0.55 1 1 off off off off off off off off off off off off off off off off off off off kg off off m off off SD437360 ISSUE 33 13.2 EXTRA PIPE WORK FITTINGS, AW600/900 MACHINES (NO LPHW) 24 25 21 36 37 72 29 72 30 31 72 71 70 69 68 14 38 36 13 37 68 72 69 38 WATER PROBE POSITION 36 82 49 72 30 29 Page 85 SD437360 ISSUE 33 AW MACHINES CONTAIN PARTS LISTED HERE WITH RELEVANT PARTS ON AA LIST EXTRA PARTS FOR FRIDGE BOX AW600/900A/BVHXF (NO LPHW) ITEM NO. PART No. 13 14 21 24 25 29 30 31 36 37 38 45 49 64 68 69 70 71 72 82 SD417650 SD177002 SD084550 SD103750 SD085450 SD466751 SD466752 SD239357 SD216452 SD466550 SD239358 SD284450 SD448750 SD111050 SD466552 SD203950 SD110151 SD224751 SD216454 SD090150 DESCRIPTION COAX MOUNTING BKT COAX COIL ASSY NRV 3/8 REVERSING VALVE REV VALVE COIL 1 inch PVC GREY TANK CONN PVC PLAIN SOCKET 1 inch 1inch PVC GREY 90deg ELBOW 3/4 PVC RIGID PIPE 1 x 3/4 REDUCING BUSH 3/4x3/4inch 45deg GREY PVC ELBOW 1/8 BSPM BLEED VALVE (PEGLER) TEMPERATURE PROBE FLEXIBLE PIPE CLEAR PVC 16mm BORE 3/4 x1/2inch PVC REDUCING BUSH PIPE NOMINAL DIA 1/2IN PVC-U HOSE CLIP S/STEEL SIZE 35 FLEXIBLE HOSE DIA 22ID 1inch PVC GREY PLAIN PIPE COPPER EARTH STRAP Page 86 QUAN UNITS 1 1 1 1 1 2 2 2 1.6 2 2 1 1 0.55 2 0.26 4 0.17 1.25 0.15 off off off off off off off off m off off off off m off m off m m m SD437360 ISSUE 33 13.2 EXTRA PIPE WORK FITTINGS, AW1200/1500 MACHINES. AW1500BVHXF ONLY 74 42 78 43 41 79 33 79 33 41 39 40 76 33 39 76 26 27 24 13 74 78 42 Page 87 SD437360 ISSUE 33 AW MACHINES CONTAIN PARTS LISTED HERE WITH RELEVANT PARTS ON AA LIST EXTRA PARTS FOR AW1200A/BVHXF AND AW1500BVHXF (NO LPHW) ITEM NO. PART No. 13 20 23 25 26 27 31 33 39 40 41 42 74 76 77 78 79 SD353451 SD085450 SD084550 SD061750 SD466751 SD466752 SD239357 SD216452 SD466550 SD239358 SD466552 SD216453 SD110150 SD203950 SD239359 SD224754 SD239355 DESCRIPTION CONDENSER CN2 REV COIL NRV 3/8 REVERSING VALVE V30 1 inch PVC GREY TANK CONN PVC PLAIN SOCKET 1 inch 1inch PVC GREY 90deg ELBOW 3/4 PVC RIGID PIPE 1 x 3/4 REDUCING BUSH 3/4x3/4inch 45deg GREY PVC ELBOW 3/4 x1/2inch PVC REDUCING BUSH PIPE NOMINAL DIA 1/2IN PVC-U HOSE CLIP S/STEEL SIZE 25 1inch PVC GREY PLAIN PIPE 1/2x1/2 90DEG ELBOW FLEXIBLE HOSE DIA 19ID ELBOW 3/4 X 3/4 90 DEG Page 88 QUAN UNITS 1 1 1 1 2 2 2 1.6 2 2 2 1.25 8 1.25 4 0.4 2 off off off off off off off m off off off m off m off m off SD437360 ISSUE 33 13.3 EXTRA PIPE WORK FITTINGS, AW6/900 MACHINES WITH LPHW FITTED B B AB A A ORIENTATION BOTH VALVES 27 58 28 TO LPHW 30 101 27 98 38 1/2 95 31 96 92 3/4 1" 15 29 28 98 98 38 TO LPHW PART VIEWS Page 89 SD437360 ISSUE 33 AW MACHINES WITH LPHW CONTAIN PARTS LISTED HERE WITH RELEVANT PARTS ON AA & AW LISTS EXTRA PARTS FOR AW600/900A/BVHXF WITH LPHW FITTED ITEM NO. PART No. 15 15a 27 28 29 30 31 34 37 38 58 68 69 82 92 95 96 98 100 SD418950 SD418951 SD323903 SD236852 SD236853 SD224755 SD290653 SD110156 SD466550 SD290651 SD284450 SD466552 SD203950 SD090150 SD243654 SD239355 SD467450 SD296153 SD224755 DESCRIPTION PLATE HEAT EXCHANGER, AW600 PLATE HEAT EXCHANGER, AW900 MOTORISED VALVE 3 PORT GATEVALVE 22mm GATEVALVE 15mm HOSE 13 I/D COMPRESSION FITTING 22 x 3/4BSPM HOSE CLIP S/STEEL SIZE 20 1 x 3/4 REDUCING BUSH COMPRESSION FITTING 15x1/2BSPM BLEED VALVE 3/4 x1/2inch PVC REDUCING BUSH PIPE NOMINAL DIA 1/2IN PVC-U COPPER EARTH STRAP 1" PVC GREY EQUAL T ELBOW 3/4 X 3/4 90 DEG 1/2" PVC/BRASS COMP UNION HOSE TAIL 13mm x 1/2 BSPM FLEXIBLE HOSE DIA 13ID Page 90 QUAN UNITS 1 1 2 1 1 1.6 2 4 2 4 1 2 0.32 0.15 2 8 2 4 1.6 off off off off off m off off off off off off m m off off off off m SD437360 ISSUE 33 13.4 EXTRA PIPE WORK FITTINGS, AW12/1500 MACHINES WITH LPHW FITTED B B AB A A ORIENTATION BOTH VALVES 97 115 114 109 116 30 TO LPHW 11 57 100 27 15 31 101 28 114 31 PART VIEWS Page 91 SD437360 ISSUE 33 EXTRA PARTS FOR AW1200/1500 WITH LPHW FITTED ITEM NO. PART No. 11 15 15a 27 28 30 31 57 87 92 93 94 95 96 97 98 100 101 104 109 114 115 116 SD417651 SD418951 SD418952 SD323903 SD236852 SD224756 SD290653 SD284450 SD090150 SD216455 SD216452 SD216454 SD466550 SD466552 SD243654 SD239358 SD239355 SD467450 SD239356 SD466753 SD296154 SD110151 SD466551 DESCRIPTION HEATER MOUNTING BKT PLATE HEAT EXCHANGER AW1200 PLATE HEAT EXCHANGER AW1500 MOTORISED VALVE 3 PORT GATEVALVE 22mm FLEXIBLE HOSE DIA 19ID (GATES GP40) COMPRESSION FITTING 22 x 3/4BSPM BLEED VALVE COPPER EARTH STRAP 20mm PVC GREY RIGID PIPE 3/4 PVC RIGID PIPE 1" PVC GREY PLAIN PIPE 1 x 3/4 REDUCING BUSH 3/4" - 1/2" PVC REDUCING BUSH 1" PVC GREY EQUAL T 3/4"x3/4" 45DEG GREY PVC ELBOW ELBOW 3/4 X 3/4 90 DEG 1/2" PVC/BRASS COMP UNION 20 x 20 90deg ELBOW REDUCING SOCKET PLAIN 3/4" - 25mm HOSE TAIL 19mm x3/4 BSPM HOSE CLIP S/STEEL SIZE 35 25mm x 20mm REDUCING BUSH Page 92 QUAN UNITS 1 1 1 2 2 1.6 4 1 0.15 0.32 1.6 1.25 2 2 2 1 3 2 2 2 4 4 2 off off off off off m off off m m m m off off off off off off off off off off off SD437360 ISSUE 33 14.0 FAN BOX ASSEMBLY SPARE PARTS LIST 3 4 9 ASSY No A419001 AT ISS 4 (10/6/2005). FAN BOX ASSY 600+LPHW ITEM NO. PART No. DESCRIPTION 2 3 4 9 2 QUAN UNITS 1 1 1 1 off off off off 1 1 off off SD127103 FAN ASSY 1450RPM 376W SD416101 LPHW COIL SD417002 FAN PANEL SD417950 FAN DUCT NON 'F' FAN ASSY SD380301 FAN ASSY 900RPM 184W D012453 FAN ADAPTOR PLATE ASSY No A419004 AT ISS 3 (10/6/2005). FAN BOX ASSY 900+LPHW ITEM NO. PART No. DESCRIPTION 2 3 4 9 2 SD127104 FAN ASSY 1450RPM 550W SD416101 LPHW COIL SD417002 FAN PANEL SD417950 FAN DUCT NON 'F' FAN ASSY SD127102 FAN ASSY 950RPM 245W Page 93 QUAN UNITS 1 1 1 1 off off off off 1 off SD437360 ISSUE 33 22 4 2 9 ASSY No A419007 AT ISS 5 (11/6/2005). FAN BOX ASSY 1200A+LPHW ITEM NO. PART No. DESCRIPTION 2 4 9 22 SD127108 FAN ASSY DDC270-270 SD417009 FAN PANEL SD417950 FAN DUCT SD416102 LPHW COIL ASSY Page 94 QUAN UNITS 1 1 1 1 off off off off SD437360 ISSUE 33 27 31 23 22 25 4 2 9 24 ASSY No A419013 AT ISS 4 (11/6/2005). FAN BOX ASSY 1500B+LPHW ITEM NO. PART No. DESCRIPTION 2 4 9 22 23 24 25 27 31 22 23 24 SD435501 FAN ASSY BDC270-270 SD417009 FAN PANEL SD417950 FAN DUCT SD093550 MOTOR 1.5KW 1420RPM (MT90/L4) SD347452 PULLEY 100 PCD x 1SPA 24 BORE ALI' SD347451 PULLEY 100 PCD x1SPA 20 BORE ALI' SD070356 BELT SPA1000 PB SD416102 LPHW COIL ASSY SD388852 M5 STUDDING 360mm LONG NON 'F' VERSION SD288150 MOTOR 1.1KW 2850RPM (MT90/L4) SD248951 PULLEY 80 PCD x 1SPA 24 BORE ALI' (MOTOR) SD327250 PULLEY 200 PCD x1SPA 20 BORE ALI' Page 95 QUAN UNITS 1 1 1 1 1 1 1 1 1 off off off off off off off off off 1 1 1 off off off SD437360 ISSUE 33 15.0 FINAL ASSEMBLY SPARE PARTS LIST TOP OUTLET PANEL INTERCHANGABLE WITH ITEM 6 6 9 8 8 10 4 5 ASSY No A471701 AT ISS 1 (16/06/2005). SHOP BUILD AA/AW6/900A/BVHXF ITEM NO. PART No. 4 5 6 7 8 9 10 SD417750 SD417850 SD417001 SD460601 SD418750 SD417004 SD460501 SD437350 DESCRIPTION FOOT INFILL PANEL SIDE PANEL PANEL HALF INSULATION SIDE PANEL CONSOLE FIXING ELEC BOX COVER INSTALLATION MANUAL QUAN UNITS 2 1 5 1 6 1 1 1 off off off off off off off off ASSY No A472101 AT ISS 1 (17/06/2005). SHOP BUILD AA/AW12/1500A/BVHXF ITEM NO. PART No. 4 5 6 7 8 9 10 SD417752 SD417851 SD417008 SD460602 SD418761 SD417010 SD460502 SD437350 DESCRIPTION FOOT INFILL PANEL SIDE PANEL PANEL HALF INSULATION SIDE PANEL CONSOLE FIXING ELEC BOX COVER INSTALLATION MANUAL Page 96 QUAN UNITS 2 1 5 1 6 1 1 1 off off off off off off off off SD437360 ISSUE 33 16.0 FINAL ASSEMBLY SPARE PARTS LIST DOWN DRAUGHT 5 7 14 PANEL INTERCHANGABLE WITH ITEM 5 8 5 7 7 2 4 17 ASSY No A471706 AT ISS 1 (17/06/2005). SHOP BUILD AA/AW6/900A/BVHXF ITEM NO. PART No. 4 5 6 7 8 14 17 SD417750 SD417001 SD460601 SD418750 SD417004 SD460501 SD417951 SD437350 DESCRIPTION FOOT SIDE PANEL PANEL HALF INSULATION SIDE PANEL, CONSOLE FIXING ELEC BOX COVER DUCT INSTALLATION MANUAL QUAN UNITS 2 6 1 7 1 1 1 1 off off off off off off off off ASSY No A472106 AT ISS 1 (17/06/2005). SHOP BUILD AA/AW12/1500A/BVHXF ITEM NO. PART No. 4 5 6 7 8 14 17 SD417752 SD417008 SD460602 SD418761 SD417010 SD460502 SD417951 SD437350 DESCRIPTION FOOT SIDE PANEL PANEL HALF INSULATION SIDE PANEL, CONSOLE FIXING ELEC BOX COVER DUCT INSTALLATION MANUAL Page 97 QUAN UNITS 2 6 1 7 1 1 1 1 off off off off off off off off SD437360 ISSUE 33 FINAL ASSEMBLY SPARE PARTS LIST HORIZONTAL 017 PANEL INTERCHANGABLE WITH ITEM 6 008 008 009 007 006 % RH M AX HUMIDITY AUTO AIR TEMP = AUTO WATER TEMP M IN = = AUTO 018 025 004 005 ASSY No A471711 AT ISS 1 (17/06/2005). SHOP BUILD AA/AW6/900A/BVHXF ITEM NO. PART No. 4 5 6 7 8 9 17 18 25 SD417750 SD417850 SD417001 SD460601 SD418750 SD417004 SD460501 SD417751 SD417003 SD437350 DESCRIPTION FOOT INFILL PANEL SIDE PANEL PANEL HALF INSULATION SIDE PANEL, CONSOLE FIXING ELEC BOX COVER FAN BOX FOOT FAN BOX FOOT PANEL INSTALLATION MANUAL QUAN UNITS 2 1 4 1 5 1 1 1 1 1 off off off off off off off off off off ASSY No A472111 AT ISS 1 (17/06/2005). SHOP BUILD AA/AW12/1500A/BVHXF ITEM NO. PART No. 4 5 6 7 8 9 17 18 25 SD417752 SD417851 SD417008 SD460602 SD418761 SD417010 SD460502 SD417753 SD417011 SD437350 DESCRIPTION FOOT INFILL PANEL SIDE PANEL PANEL HALF INSULATION SIDE PANEL, CONSOLE FIXING ELEC BOX COVER FAN BOX FOOT FAN BOX FOOT PANEL INSTALLATION MANUAL Page 98 QUAN UNITS 2 1 4 1 5 1 1 1 1 1 off off off off off off off off off off SD437360 ISSUE 33 17.0 FRESH AIR BOX SPARE PARTS LIST 14 7 18 19 TERMINAL BOX VIEW ON ARROW 'A' 12 15 3 A 6 2 2 ASSY No A433001 AT ISS 7 (04/06/2013). FRESH AIR BOX ASSY 6/900 ITEM NO. PART No. 2 3 6 7 8 12 14 15 18 19 SD417005 SD417007 SD431051 SD521250 SD441350 SD275310 SD174153 SD264653 SD217250 SA072853 DESCRIPTION SIDE PANEL SPIGOT PANEL FAN ASSEMBLY MOTOR DAMPER VOLUME CONTROL DAMPER 10 inch DUCT SPIGOT BOX ALUM DIECAST DRILLED AIR FILTER CAPACITOR 8µF 500V 5 WAY TERMINAL BLOCK QUAN UNITS 3 1 1 1 1 2 1 1 1 1 off off off off off off off off off off ASSY No A433002 AT ISS 7 (04/06/2013). FRESH AIR BOX ASSY 12/1500 ITEM NO. PART No. 2 3 6 7 8 12 14 15 18 19 SD417012 SD417014 SD431051 SD521250 SD441350 SD275310 SD174153 SD264653 SD217250 SA072853 DESCRIPTION SIDE PANEL SPIGOT PANEL FAN ASSEMBLY MOTOR DAMPER VOLUME CONTROL DAMPER 9 inch DUCT SPIGOT BOX ALUM DIECAST DRILLED AIR FILTER CAPACITOR 8µF 440V 5 WAY TERMINAL BLOCK Page 99 QUAN UNITS 3 1 1 1 1 2 1 1 1 1 off off off off off off off off off off SD437360 ISSUE 33 14 18 19 12 8 TERMINAL BOX VIEW ON ARROW 'A' 3 A 6 2 ASSY No A433005 AT ISS 1 (28/06/2012). NEGATIVE PRESSURE BOX ASSY 6/900 ITEM NO. PART No. 2 3 6 7 8 12 14 18 19 SD417005 SD417007 SD101450 SD521250 SD441350 SD275309 SD174153 SD106550 SA072853 DESCRIPTION SIDE PANEL SPIGOT PANEL FAN CENTRIFUGAL 1050RPM MOTOR DAMPER VOLUME CONTROL DAMPER 6 inch DUCT SPIGOT BOX ALUM DIECAST DRILLED CAPACITOR 2uF 440V 5 WAY TERMINAL BLOCK QUAN UNITS 3 1 1 1 1 1 1 1 1 off off off off off off off off off ASSY No A433006 AT ISS 1 (28/06/2012). NEGATIVE PRESSURE BOX ASSY 12/1500 ITEM NO. PART No. 2 3 6 7 8 12 14 18 19 SD417012 SD417014 SD101450 SD521250 SD441350 SD275309 SD174153 SD106550 SA072853 DESCRIPTION SIDE PANEL SPIGOT PANEL FAN CENTRIFUGAL 1050RPM MOTOR DAMPER VOLUME CONTROL DAMPER 6 inch DUCT SPIGOT BOX ALUM DIECAST DRILLED CAPACITOR 2uF 440V 5 WAY TERMINAL BLOCK Page 100 QUAN UNITS 3 1 1 1 1 1 1 1 1 off off off off off off off off off SD437360 ISSUE 33 18.0 HEATER BOX ASSEMBLY SPARE PARTS LIST 3 13 56 14 EARTH STUD 8 15 3 1 3 5 2 4 6 1 BLUE 11 12 57 BRO WN BROWN BRO WN 2 17 BLUE BLUE MCB ENL 16 10 PROBE FROM THERMOSTAT 4 ASSY No A440001 AT ISS 4 (29/03/2007). HEATER BOX ASSY 6kW 1P 6/900 ITEM NO. PART No. 3 4 7 8 9 10 11 12 13 14 15 16 17 56 57 SD417001 SD417017 SD253651 SD417004 SD068601 SD316556 SD103251 SD103252 SD089550 SD419550 SD403550 SD403750 SD409350 SA253951 SD090150 DESCRIPTION SIDE PANEL SIDE PANEL (MAINS IN) HEATER ELEMENT 2kW SIDE PANEL, CONSOLE FIXING CONTACTOR CI 16 230v 50Hz MCB 32A 1 POLE THERMAL CUTOUT AUTO RESET THERMAL CUTOUT MANUAL RESET DELAY TIMER 7 SEC TO 9 MIN DISTRIBUTION TERM BLOCK TERM EARTH WPE6 8mm TERM BLOCK WDU4 TERM BLOCK WDU 2.5N THERMOSTAT SET TO 65ºC COPPER EARTH STRAP Page 101 QUAN UNITS 2 1 3 1 1 1 1 1 1 2 1 2 6 1 0.15 off off off off off off off off off off off off off off m SD437360 ISSUE 33 ASSY No A440002 AT ISS 7 (02/09/2011). HEATER BOX ASSY 12kW 1P 6/900 ITEM NO. PART No. 3 4 7 8 9 10 11 12 13 14 15 16 17 54 56 57 SD417001 SD417017 SD253651 SD417010 SD262601 SD316559 SD103251 SD103252 SD089550 SD419550 SD406351 SD406350 SD409350 SD403950 SA253951 SD090150 DESCRIPTION SIDE PANEL SIDE PANEL (MAINS IN) HEATER ELEMENT 2kW SIDE PANEL, CONSOLE FIXING CONTACTOR CI32 230V 50Hz MCB 63A 1 POLE THERMAL CUTOUT AUTO RESET THERMAL CUTOUT MANUAL RESET DELAY TIMER 7 SEC TO 9 MIN DISTRIBUTION TERM BLOCK TERM BLOCK EARTH (SL16) TERMINAL BLOCK WDU16 TERM BLOCK WDU 2.5N END BRACKET EW35 (8.5) THERMOSTAT SET TO 65ºC COPPER EARTH STRAP QUAN UNITS 2 1 6 1 1 1 1 1 1 2 1 2 6 1 1 0.15 off off off off off off off off off off off off off off off m ASSY No A440003 AT ISS 7 (02/09/2011). HEATER BOX ASSY 12kW IP 1200 ITEM NO. PART No. 3 4 7 8 9 10 11 12 13 14 15 16 17 54 57 58 SD417008 SD417018 SD253651 SD3417010 SD262601 SD316559 SD103251 SD103252 SD089550 SD419550 SD406351 SD406350 SD409350 SD403950 SA253951 SD090150 DESCRIPTION SIDE PANEL SIDE PANEL (MAINS IN) HEATER ELEMENT 2kW SIDE PANEL, CONSOLE FIXING CONTACTOR CI32 230V 50Hz MCB 63A 1 POLE THERMAL CUTOUT AUTO RESET THERMAL CUTOUT MANUAL RESET DELAY TIMER 7 SEC TO 9 MIN DISTRIBUTION TERM BLOCK TERM BLOCK EARTH (SL16) TERMINAL BLOCK WDU16 TERM BLOCK WDU 2.5N END BRACKET EW35 (8.5) THERMOSTAT SET TO 65ºC COPPER EARTH STRAP Page 102 QUAN UNITS 2 1 6 1 1 1 1 1 1 2 1 2 6 1 1 0.15 off off off off off off off off off off off off off off off m SD437360 ISSUE 33 HEATER BOX ASSY SPARE PARTS LIST CONTINUED 3 13 10 EARTH STUD 55 DELAY TIMER 15 1 3 8 17 2 4 3 5 EL L L 1 3 5 2 4 6 7 6 11 12 56 16 THERMOSTAT PROBE 4 ASSY No A440005 AT ISS 4 (29/03/2007). HEATER BOX ASSY 6kW 3P 6/900 ITEM NO. PART No. 3 4 7 8 9 10 11 12 13 14 15 16 17 55 56 SD417001 SD417017 SD253651 SD417004 SD068201 SD325253 SD103251 SD103252 SD089550 SD403950 SD403550 SD403750 SD409350 SA253951 SD090150 DESCRIPTION SIDE PANEL SIDE PANEL (MAINS IN) HEATER ELEMENT 2kW SIDE PANEL, CONSOLE FIXING CONTACTOR CI9 230V 50Hz MOTOR STARTER O/LOAD 6.3-10A THERMAL CUTOUT AUTO RESET THERMAL CUTOUT MANUAL RESET DELAY TIMER 7 SEC TO 9 MIN END BRACKET EW35 (8.5) TERM EARTH WPE6 8mm TERM BLOCK WDU4 TERM BLOCK WDU 2.5N THERMOSTAT SET TO 65ºC COPPER EARTH STRAP Page 103 QUAN UNITS 2 1 3 1 1 1 1 1 1 1 1 3 6 1 0.15 off off off off off off off off off off off off off off m SD437360 ISSUE 33 ASSY No A440006 AT ISS 4 (29/03/2007). HEATER BOX ASSY 12kW 3P 6/900 ITEM NO. PART No. 3 4 7 8 9 10 11 12 13 14 15 16 17 55 56 SD417001 SD417017 SD253651 SD417004 SD068601 SD325254 SD103251 SD103252 SD089550 SD403950 SD403550 SD403750 SD409350 SA253951 SD090150 DESCRIPTION SIDE PANEL SIDE PANEL (MAINS IN) HEATER ELEMENT 2kW SIDE PANEL, CONSOLE FIXING CONTACTOR CI 16 230v 50Hz MOTOR STARTER O/LOAD 10-16A THERMAL CUTOUT AUTO RESET THERMAL CUTOUT MANUAL RESET DELAY TIMER 7 SEC TO 9 MIN END BRACKET EW35 (8.5) TERM EARTH WPE6 8mm TERM BLOCK WDU4 TERM BLOCK WDU 2.5N THERMOSTAT SET TO 65ºC COPPER EARTH STRAP QUAN UNITS 2 1 6 1 1 1 1 1 1 1 1 3 6 1 0.15 off off off off off off off off off off off off off off m ASSY No A440007 AT ISS 5 (29/03/2007). HEATER BOX ASSY 12kW 3P 12/1500 ITEM NO. PART No. 3 4 7 8 9 10 11 12 13 14 15 16 17 55 56 SD417008 SD417018 SD253651 SD417010 SD068601 SD325254 SD103251 SD103252 SD089550 SD403950 SD403550 SD403750 SD409350 SA253951 SD090150 DESCRIPTION SIDE PANEL SIDE PANEL (MAINS IN) HEATER ELEMENT 2kW SIDE PANEL, CONSOLE FIXING CONTACTOR CI 16 230v 50Hz MOTOR STARTER O/LOAD 10-16A THERMAL CUTOUT AUTO RESET THERMAL CUTOUT MANUAL RESET DELAY TIMER 7 SEC TO 9 MIN END BRACKET EW35 (8.5) TERM EARTH WPE6 8mm TERM BLOCK WDU4 TERM BLOCK WDU 2.5N THERMOSTAT SET TO 65ºC COPPER EARTH STRAP QUAN UNITS 2 1 6 1 1 1 1 1 1 1 1 3 6 1 0.15 off off off off off off off off off off off off off off m ASSY No A440008 AT ISS 5 (29/03/2007). HEATER BOX ASSY 18kW 3P 12/1500 ITEM NO. PART No. DESCRIPTION 3 4 7 8 9 10 11 12 13 14 15 16 17 55 56 SD417008 SD417018 SD253651 SD417010 SD068801 SD325257 SD103251 SD103252 SD089550 SD403950 SD403550 SD403750 SD409350 SA253951 SD090150 SIDE PANEL SIDE PANEL (MAINS IN) HEATER ELEMENT 2kW SIDE PANEL, CONSOLE FIXING CONTACTOR CI25 CIRCUIT BREAKER 20-25A 3P THERMAL CUTOUT AUTO RESET 60 deg C THERMAL CUTOUT MANUAL RESET 90 C DELAY TIMER 7 SEC TO 9 MIN END BRACKET EW35 (8.5) TERM EARTH W PE6 8mm TERM BLOCK W DU4 TERM BLOCK W DU 2.5N THERMOSTAT SET TO 65 C COPPER EARTH STRAP Page 104 QUAN UNITS 3 1 9 1 1 1 1 1 1 1 1 3 6 1 0.15 off off off off off off off off off off off off off off m SD437360 ISSUE 33 19.0 REMOTE SENSOR BOX P 0.5 0 0.5 R 0.5 REMOTE SENSOR BOX SA473601 TOP SIDE OF BASE (COVER REMOVED) 1 3 3 2 1 1 2 3 4 5 B BR R 0.5 2 0 0.5 B P 0.5 BR SA473601 ITEM PART No. DESCRIPTION QUAN UNITS 001 SD260351 HUMIDITY SENSOR 1.00 off 002 SD448750 PTC SENSOR LEAD (TECNOLOGIC) 1.00 off 003 SA098761 5 WAY TERMINAL BLOCK 6A 1.00 off NOTE: HUMIDITY SENSOR STYLE VARIES WITH MANUFACTURER (DIXELL XH20P SHOWN) TERMINAL LAYOUT FOR EACH HUMDITY SENSOR SENSOR VOLT SUPPLY OV COM 0-10 V DIXELL 1 2 3 RENSE 5 3 4 P7 P6 P5 P4 P3 P2 P1 DISCONNECT LEADS THIS SIDE & REPLACE W IT H REMOT E SENSOR LEADS B LB GR V 0,5 PU W 0,5 SENSOR BOX TERM 5 SENSOR BOX TERM 4 SENSOR BOX TERM 3 SENSOR BOX TERM 2 SENSOR BOX TERM 1 SENSOR/PROBE TB RE1 RE2 RE3 RE4 R1 R2 R3 R11 TIMER DELAY LOOM R14 ELECTRIC BOX RECOMMENDED INTERFACE CABLE : CALOREX PART No. D523450, 6 CORE SCREENED CABLE. Page 105 SD437360 ISSUE 33 20.0 DUCT FLANGE KITS DUCT FLANGES INSTALLATION INSTRUCTIONS SEALANT ON INSIDE CORNERS & FLANGE CORNER PIECES 2 1 3 DUCTING ITEM DESCRIPTIONS ITEM 1 DUCT FLANGE SD347650 ITEM 2 FLANGE CORNER PIECES SD347550 ITEM 3 SILICON SEALANT D250350 NOTES 1. USING TABLE BELOW CUT DUCT FLANGES TO SIZES STATED FOR REQUIRED MACHINE 2. PUSH CORNER PIECES ( 4 OFF ITEM 2 ) INTO FLANGES TO FORM REQUIRED DUCT SIZE. 3. PUSH ASSEMBLED FLANGE ON TO DUCT, & GENTLY TAP HOME. 4. SEAL ALL INSIDE CORNERS USING SILICONE SEALANT. MODEL DUCT DESCRIPTION DUCT FLANGE CUT SIZES (ITEM 1) VARIHEAT 3 - 6/900 INLET DUCT 2 OFF 585mm LENGTHS & 2 OFF 630mm LENGTHS VARIHEAT 3 - 12/1500 INLET DUCT 2 OFF 660mm LENGTHS & 2 OFF 750mm LENGTHS VARIHEAT 3 OUTLET DUCT 2 OFF 260mm LENGTHS & 2 OFF 303mm LENGTHS Page 106 SD437360 ISSUE 33 SA185551 P033650 P250250 P036052 P018752 SP090150 P090151 P090152 P090153 001 002 003 004 005 006 007 008 009 M5 BRASS NUT M5 BRASS WASHER M5 BRASS SCREW COPPER EARTH STRAP SCREW M4 x 6 PAN HEAD POZI WIRE PIN FLARED ENTRY RED PUSH ON FLARED ENTRY RED (1/4in) WIRE 0.5mm RED/ORANGE 6 DEG FROST PROTECTION STAT DESCRIPTION Page 107 DRAWING CHANGE ITEM 1 - WAS 185550 C/N 1349 VIEW OF ELEC BOX ASSY UPDATED 2 1349/3 CIRCUIT DIAGRAM NOTE ADDED 3 1569 AND FIX PROBE AS SHOWN TO LPHW BRACE. 08:02:11 APPD AJB DATE 09/07/09 GSM 19:08:10 DH 3. ROUTE CAPILLARY AS SHOWN ON RELEVANT MACHINE LAYOUT DIAGRAMS :- D459850 or D459851 ALSO IF REQUIRED REFER TO STANDARD MACHINE WIRING CUT TO REQD LENGTH & CRIMP ON TERMINALS. REWIRE AS SHOWN ON D459856 USING R/O WIRE LISTED 2. DISCONNECT EXSISTING R/O WIRE FROM R7 TERM 4 AND ACCORDING TO LAYOUT OF MACHINE. 4 ISS 2.00 2.00 2.00 200.00 2.00 1.00 3.00 1600.00 1.00 QUAN 1. FIT THERMOSTAT INTO ELEC BOX AS SHOWN. POSN VARIES FITTING INSTRUCTIONS PART No. ITEM SA533503 WIRING DIAGRAM D459850/1 SHEET 2 FOR CIRCUIT DIAGRAM REFER TO STANDARD MACHINE off off off R6 RE2 R7 17 RE3 R8 RE4 27 R9 R1 008 DO NOT INSULATE STAT PROBE 007 LPHW FIN COIL BLOCK 100mm 006 ELEC BOX ASSY E N LL L R13 R5 RE1 C CALOREX HEAT PUMPS LTD U.C.C. mm off off off mm off UNITS R 009 R10 R2 R3 2 4 4 001 005 FINISH MATERIAL DOWNDRAUGHT VERSIONS STAT IN THIS POSN FOR 1 3 3 51 R4 TOP OUTLET & HORIZONTAL VERSIONS STAT IN THIS POSN FOR B OILER 001 REMOT E FROST PROTECTION KIT DESCRIPTION USED TO PROTECT LPHW FROM FROST DAMAGE. SYSTEM ENERGISES WHEN AMBIENT TEMPERATURE DROPS BELOW 6 DEGREES. ON/OFF 005 DEMAND POOL PUMP DO NOT SCALE PRINT START REMOTE OC C/UNOCC UPIED NOTES IF IN DOUBT ASK HOLES TO BS 4500 E12 INSPECTION LEVEL TITLE VH3 RANGE FROST PROTECTION KIT HORIZONTAL VERSION DIMS TOLERANCE UNLESS SPECIFIED --- CONT' DRG No. 1 SHT No 31:8:07 DATE NTS SCALE SA533503 SA533503 GSM DRAW N APPD DRG No. DOWNDRAUGHT VERSION STAT CAPILLARY ROUTES SEE BELOW TOP OUTLET VERSION 3rd ANGLE PROJECTION 21.0 FROST PROTECTION KITS SD437360 ISSUE 33 Page 108 SD437360 ISSUE 33 P079650 D613750 D605653 P032150 P030350 P030150 P031650 016 017 018 019 020 021 022 SCREW SELF TAP No6 X 1/4 WASHER PLAIN BRASS M3 M3 HALF NUT M3 x 6 POZI PAN HD SCREW PUSH ON FLARED ENTRY BLUE (1/4in) WIRE PIN FLARED ENTRY BLUE No.TAGS No AS SHOW N WIRE 0.5mm RED WIRE 1.5mm GREEN/YELLOW WIRE 0.5mm BLUE WIRE 2.5mm RED WIRE 0.5mm BROWN RELAY LABEL FKR1 TERMINAL LABEL - L N E FUSE CLIP TERM EARTH WPE6 8mm TERM BLOCK WDU 2.5N FUSE LABEL F 1A 500VAC FUSE 1/4 x 1 1/4 1A FUSE HOLDER RELAY C/O 2 POLE 16A 230vac COIL M5 BRASS NUT M5 BRASS WASHER M5 BRASS SCREW COPPER EARTH STRAP SCREW M4x6 PAN HEAD POZI WIRE PIN FLARED ENTRY RED PUSH ON FLARED ENTRY RED (1/4in) WIRE 0.5mm RED/ORANGE 6 DEG FROST PROTECTION STAT DESCRIPTION ISS 1 2 DRAWING CHANGE STANDARD KIT AMAGAMATED FROM SA533503 & OD773 REDRAWN WITH ALL CORRECTIONS & VIEWS ADDED IE TERM No'S WERE 60,61,62 RELAY WAS RE3, WIRES ADDED ETC 3 CIRCUIT DIAGRAM NOTE ADDED AND FIX PROBE AS SHO WN TO LPHW BRACE. C/N 1349 1349/3 1569 3. ROUTE CAPILLARY AS SHOWN ON RELEVANT MACHINE LAYOUT DIAGRAMS :- D459850 o r D459851 ALSO IF REQUIRED REFER TO STANDARD MACHINE WIRING CUT TO REQD LENGTH & CRIMP ON TERMINALS. REWIRE AS SHOWN ON D4598 56 USING WIRES LISTED 2. DISCO NNECT EXSISTING R/O WIRE FROM R7 TERM 4 AND POSN VARIES ACCORDING TO LAYOUT OF MACHINE . 1. FIT THERMOSTAT & OTHER COMPONENTS INTO ELEC BOX AS SHOWN. FITTING INSTRUCTIONS P108251 SD403550 015 030 SD409350 014 P069550 P165950 013 029 SD035353 012 P069650 SD216550 011 P080250 SD189550 010 P250251 P090153 009 028 P090152 008 027 P090151 007 026 SP090150 006 P036050 P018752 005 025 P036052 004 P051650 P250250 003 P030450 P033650 002 024 SA185551 001 023 PART No. ITEM SA533506 WIRING DIAGRAM D459850/1 SHEET 2 DH APPD AJB GSM off off off off off off off mm mm mm mm mm off off off off off off off off off off off off mm off off off mm off UNITS DATE 15:05:09 06:09:10 08:02:11 2.00 2.00 2.00 2.00 1.00 1.00 3.00 600.00 750.00 750.00 350.00 750.00 1.00 1.00 1.00 1.00 2.00 1.00 2.00 1.00 1.00 2.00 2.00 2.00 200.00 2.00 3.00 4.00 750.00 1.00 QUAN CALOREX HEAT PUMPS LTD U.C.C. c 025 020 026 012 R RED 0.5 No.TAGS 024 014 004 019 59 DAMPER REMOTE EXTERNAL L N E 57 58 021 7 RED 0.5 A 4 1 BROWN 0.5 003 FINISH MATERIAL 006 007 015 IN MACHINE ELEC BOX 017 008 LPHW FIN COIL BLOCK 009 022 002 EARTH STUD TO MAIN G/Y 1.5 DIN RAIL TERMINALS DO NOT INSULATE STAT PROBE 100mm B 9 6 3 FKR1 ALSO REFER TO WIRING DIAGRAM D459856 44 45 021 023 RED/ORANGE 0.5 FOR CIRCUIT DIAGRAM REFER TO STANDARD MACHINE BLUE 0.5 NOTES BLUE 0.5 E N LL L R13 R5 INSPECTION LEVEL HOLES TO BS 4500 E12 TOLERANCE UNLESS SPECIFIED 016 013 012 011 RE1 001 R6 R E2 TART S REMOTE ON/ OF F 17 R8 RE4 27 R9 R10 R2 017 R1 R3 2 4 4 DAMPE R REMOTE EXT E RNAL L N E DIMS 005 016 013 012 DOWNDRAUGHT VERSIONS STAT IN THIS POSN FOR 001 029 028 027 018 010 011 ELEC BOX ASSY 600/900 IF IN DOUBT ASK ENLL L R13 R5 RE1 R6 RE2 OCC/UNOCCUPIED REMOTE ON/ OF F R7 R E3 17 R8 RE4 27 R9 R1 R10 R2 SEE NOTE 3 VH3 RANGE FOR ADDITIONAL REMOTE DAMPER FROST PROTECTION KIT TITLE HORIZONTAL VERSION 2 DAMPE R REMOTE EXT E RNAL L N 57 58 59 1 4 4 R4 3 3 017 R3 FKR1 E DRG No. --- 1 DRG No. CONT' SHT No. 018 030 APPROVED AS SHOWN DATE 31:8:07 GROMMETED HOLE FEED CAPILLARY THRO' ELEC BOX ASSY 1200/1500 010 SA533506 SA533506 GSM DRAWN DOWNDRAUGHT VERSION STAT CAPILLARY ROUTES SEE BELOW FKR1 57 58 59 1 3 3 R4 TOP OUTLET VERSION R7 R E3 TOP OUTLET & HORIZONTAL VERSIONS OI L B ER SYSTEM ENERGISES WHEN AMBIENT TEMPERATURE DROPS BELOW 6 DEGREES. REMOTE USED TO PROTECT LPHW FROM FROST DAMAGE. RED 2.5 CONTROL MCB RED/ORANGE 0.5 STAT IN THIS POSN FOR OCC/UNOCCUPIED 005 DE MAND OOL P UM P P 3rd ANGLE PROJECTION OI L B ER DO NOT SCALE PRINT DE MAND OOL P UM P P FROST PROTECTION KIT DESCRIPTION TART S REMOTE FUSE 1A NTS SCALE 22.0 PACKING SPECIFICATIONS VH 3 TOPOUT PACKING SPECIFICATION MACHINE UK DELIVERY WEIGHT(kg) 178 198 180 200 225 245 244 265 600 A/B 600+AIR 900 A/B 900+AIR 1200 A/B 1200 AIR 1500 B 1500+AIR Hx W x D DIMENSIONS 922x772x1592 765x1255x1474 922x772x1592 765x1255x1474 885x1045x1792 865x1365x1678 885x1045x1792 1462x1850x1828 EXPORT WEIGHT(kg) 238 258 240 260 285 305 304 325 Hx W x D DIMENSIONS 1000x860x1800 1000x860x1800 1000x860x1800 1000x860x1800 1105x960x1970 1102x960x1970 1102x960x1970 1102x960x1970 VH 3 DOWNDRAUGHT PACKING SPECIFICATION MACHINE UK DELIVERY WEIGHT(kg) 225 235 227 235 272 279 291 298 600 A/B 600+AIR 900 A/B 900+AIR 1200 A/B 1200+AIR 1500 B 1500+AIR HxW xD DIMENSIONS 1850x1462x1624 1850x1462x1624 1850x1462x1624 1850x1462x1624 1850x1462x1828 1850x1462x1828 1850x1462x1828 1850x1462x1828 Hx WxD DIMENSIONS 1850x1462x1750 1850x1462x1900 1850x1462x1750 1850x1462x1900 1850x1462x1970 1850x1462x2110 1850x1462x1970 1850x1462x2110 DEPTH HEIGHT(EXPORT) WIDTH EXPORT WEIGHT(kg) 347 355 349 357 404 411 423 430 Page 109 SD437360 ISSUE 33 VH 3 HORIZONTAL PACKING SPECIFICATION MACHINE 600 A/B 600+AIR 900 A/B 900+AIR 1200 A/B 1200 AIR 1500 B 1500 AIR UK DELIVERY WEIGHT(kg) 178 198 180 200 225 245 244 265 Hx W x D DIMENSIONS 772x1602x922 765x1580x780 772x1602x922 765x1580x780 885x1802x1012 865x1365x1678 885x1802x1012 865x1365x1678 Page 110 EXPORT WEIGHT(kg) 238 258 240 260 285 305 304 325 W xHx D DIMENSIONS 860x1675x1080 860x1360x1875 860x1675x1080 860x1360x1875 960x1880x1185 960x1460x2085 960x1880x1185 960x1460x2085 SD437360 ISSUE 33