ProStrong Serial Compact substation in aluminum cabin ProStrong PTPA type Destination The ProStrong PTPA type , is an equipment designed for consumers and public lightening supplying , direct from the industrial or public electrical energy networks. It is suitable both for end user consumer (radial type) or for networking connection. Elemente Componente ■ The component elements are as follows : □ The enclosure □ consists of: ▫ OLTPAN P 60 walls , (Al/poliuretan/Al) profilated, 60mm thicknes painted with epoxipoliestheric paints; ▫ chasis constructed from zync coated sheet steel profiles ; ▫ painted aluminum thermal insulated acces doors and ventilations ; ▫ dismantable roof OLTPAN P 60 , Al /spuma poliuretan/Al) made profilat , 60mm thicknes painted with epoxipoliestheric paints; □ the acces to apparatus : ▫ external; ▫ internal; □ the internal architecture consists of: ▫ Medium voltage compartment , contains MV cells in different combinations acording to diagram; ▫ Transformer compartment , contains MV/LV transformers ( 1 or 2 acording to diagram) ▫ Low voltage compartment , contains low voltage distribution board , reactive power compensation unit , metering board. ▫ Public lightening patchboard (at request) external unit added. □ The bassement is concrete made , preformed , insulated to prevent accidental oil loses. Is fitted with special pipes access systems for cables entries and for outgoings. Medium voltage compartment ■ the medium voltage compartment is fitted with : □ Modular cells different types in different combinations acording to diagram. ▫ line cells fitted with : ▫ capsulated charge disconnector SF6 ; ▫ vacuum or SF6 protection breaker; ▫ transformer cells fitted with : ▫ capsulated charge disconnector SF6 ; ▫ vacuum or SF6 protection breaker; ▫ metering cells ; ▫ coupling cells ; ■ At request PTPA can be fitted with AAR automation and remote control Transformer compartment ■ Compartimentul transformator cuprinde : □ The power transformer ( 1/2 pcs. Acording configuration) in variants : ▫ canned ▫ tight □ The leakage oil vat from the transformer can collect the whole quantity and is provided with a gravel layer in order to avoid a fire or its extend; ■ The access into the transformer compartment is not possible , an electrical interlocking system being in charge. PTPA – 1 x 100kVA – 20 / 0,4kV PTPA – 1 x 400kVA – 20 / 0,4kV ProStrong Serial Compact substation in aluminum cabin ProStrong PTPA type Low voltage compartment ■ Low voltage compartment consists of : □ LV distribution board in 2 construction variants : □ open panel for internal acces PTPA ; □ closed board for external acces PTPA; □ Electrical equipment : □ withdrawable circuit breaker on input ; □ fuse switch disconnectors in order to protect : ▫ the outgoings to consumers ; ▫ public lightening outgoings in 2 variants : ▫ through LV acces door; ▫ with sepparately subcompartment acces : □ auxiliary circuits : ▫ inernal lightening and supply 220 Vac ; ▫ electrical interblocking; ▫ temperature meter and control; □ energy metering block (at request) ; □ reactive power factor compensation block ( at request) ; Operating conditions ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ mounting average ambient temperature 24h transport and storage temperature ambient operate temperature climatic protection relative humidity maximum altitude lifetime maximum roof weight wind speed fire category fire resistance degree external 35 0C -33 : +50 0C -40 : +50 0C N ( I – III ) 80% la 20 0C 2000 m 30 years 3000 N/m2 34 m/sec A II Note : Type tests acordance CEI 1330/95 PTPA – 1 x 630kVA – 20 / 0,4kV Technical data ■ ■ ■ ■ ■ MT/JT rated voltage; transformer power; protection degree; enclosure thermal class; acoustic medium pressure level; 20 (10) / 0,4 kV 40…1000 kVA IP45 10 K 45,6 dB Mounting and connection ■ The mounting is earth made , on cement preformed basement. The basement is placed on the uncovered earth , on minimum 750 mm depth , provided with a sized gravel layer <25 mm granulated , and a 250 mm sand layer smaller then 5 mm. ■ The cables acces is underground through acces holes from basement ; ■ The cables acces : □ by special insulated terminals into the cell lugs ; □ in terminal clamps for consumer outgoings and lightening circuits ; Construction variants PTPA – 1 x 400kVA – 20 / 0,4kV ■ The construction variants are given by : □ Transformer power □ Transformer number □ acces type □ MV network type □ energy metering type □ consumers number □ public lightening □ reactive power factor corection 40,100,160,250,400, 630, 1000kVA 1 or 2 internal / external Loop or radial MV or LV metering 4, 6, 8, 10, 12 in the enclosure / outside with/without
Similar documents
Installation Guide
Apart from any fair dealing for the purposes of study, research, criticism or review, as permitted under the Copyright Act, no part may be reproduced by any process without written permission. Inqu...
More information