Fast-Fold Installation Manual
Transcription
Fast-Fold Installation Manual
Fast-Fold ® Installation Manual [Revision: May 16, 2008 0-115-565, ©Rytec Corporation, 2002] TABLE OF CONTENTS PAGE INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 DOOR SERIAL NUMBER(S). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 HOW TO USE MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 MATERIAL, TOOLS, AND EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ADDITIONAL REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Labor and Site Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Forklift Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Electrician’s Responsibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Floor-Loop Activator Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Fill-In Material Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GENERAL ARRANGEMENT OF DOOR COMPONENTS . . . . . . . . . . . . . . . . . . . . 3 ANCHORING METHODS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Concrete, Block, or Brick Walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Wood, Block, Brick, or Insulated Walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Insulated Walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 UNCRATING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 LOCATING CENTERLINE OF DOOR OPENING . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 LOCATING SIDE PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 SIDE PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 HEAD ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 SIDE PIPES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 PANELS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Panel Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Trimming Panels (Puralon Panels Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Attaching Panels to Side Pipes (Side Pipe Doors) . . . . . . . . . . . . . . . . . . . 13 KNOB AND ROPE TIE INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Rope Tie Doors Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 SEAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Center Seal – Hypalon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Side Seal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 INSULATED SIDE PANELS AND SEALED PURALON PANELS . . . . . . 16 STANDARD SIDE PANELS AND SEALED PURALON PANELS . . . . . . 16 FREEZER DOOR SIDE SEAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 PANEL CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 DOOR SEALING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 MANUAL BRAKE RELEASE (OPTIONAL ITEM) . . . . . . . . . . . . . . . . . . . . . . . . . 18 DEFROST SYSTEM (FREEZER DOOR OPTION) . . . . . . . . . . . . . . . . . . . . . . . . . 18 Heat Lamp Fixture Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Lamp Fixture Wiring and Bulb Installation . . . . . . . . . . . . . . . . . . . . . . . . . 19 LAMP BULB AND RED SLEEVE INSTALLATION . . . . . . . . . . . . . . . . . 20 Lamp Fixture Adjustment (Warm-Side and Cold-Side Mounted Doors). . 20 Heat Lamp Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Blower Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 BLOWER SPEED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 BLOWER HEATER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Hard-Panel Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 FIN ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 ELECTRICAL SYSTEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Door Close and Open Limit Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 CLOSE LIMIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 OPEN LIMIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Hard-Panel Door Remote Limit Switch (Mandatory Item if Hard-Panel Door Is Installed) . . . . . . . . . . . . . . . . . . 24 FINAL CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 INTRODUCTION—DOOR SERIAL NUMBER(S) INTRODUCTION Drive Motor The installation of your Rytec Fast-Fold® Door is not difficult if you adhere to the procedures outlined in this manual. Any unauthorized changes to these procedures, or failure to follow the steps as outlined, will automatically void our warranty. Any changes to the working parts, assemblies, or specifications as written, that are not authorized by Rytec Corporation, will also cancel our warranty. The responsibility for the successful operation and performance of this door is yours. DO NOT INSTALL, OPERATE, OR PERFORM MAINTENANCE ON THIS DOOR UNTIL YOU READ AND UNDERSTAND ALL THE INSTRUCTIONS IN THIS MANUAL. If you have any questions, contact your Rytec representative or call the Rytec Customer Support Department at 800-628-1909. Always refer to the serial number of the door when calling the representative or Customer Support. The serial number plate is located inside one of the side panels. Refer to the Rytec System 3 Drive & Control Installation & Owner’s Manual for general information about wiring connections. The actual schematic for your particular door has been shipped with the door and is located inside the control panel. DOOR SERIAL NUMBER(S) To obtain your DOOR SERIAL NUMBER, there are three universal locations where this information can be found. These are at the inside of either side column (approximately eye level), on the drive motor, and on the inside door of the System 3 control panel. (See Figure 1.) IMPORTANT: When installing multiple doors of the same model but in different sizes, verify the serial number in the control panel with the one in the side column. Serial Number Plate Located Inside One of the Side Panels System 3 Control Panel A1500157 Figure 1 HOW TO USE MANUAL Throughout this manual, the following key words are used to alert the reader of potentially hazardous situations, or situations where additional information to successfully perform the procedure is presented: WARNING is used to indicate the potential for personal injury if the procedure is not performed as described. CAUTION is used to indicate the potential for damage to the product or property damage if the procedure is not followed as described. IMPORTANT: IMPORTANT is used to relay information CRITICAL to the successful completion of the procedure. NOTE: NOTE is used to provide additional information to aid in the performance of the procedure or operation of the door, but not necessarily safety related. 1 INSTALLATION—MATERIAL, TOOLS, AND EQUIPMENT INSTALLATION Floor-Loop Activator Requirements MATERIAL, TOOLS, AND EQUIPMENT If a floor-loop activator was ordered and shipped with your Rytec Door, the following additional items will be required to install the activator. 1. Threaded rod (¹₂-in. diameter) and other various wall anchor hardware and material. Concrete anchor bolts (¹₂-in. diameter). (See “ANCHORING METHODS” on page 3.) NOTE: For complete floor-loop installation instructions, refer to the manual that was shipped with the activator. 2. Assorted shim stock. 3. Double-sided tape (for attaching shims to wall). 4. Carpenter’s level (4-ft. minimum length). 5. Carpenter’s square. 6. Hammer drill. 7. Masonry drill bit (for ¹₂-in. diameter anchors). 8. Hammer or mallet, and block of wood. 9. Crowbar or pry bar. 10. Assorted hand tools (pliers, tape measure, etc.). 11. Socket and wrench sets. 12. Water level, line level, or transit. 13. Two ladders (taller than height of door opening). 14. Forklift (see “Forklift Requirements” below). ADDITIONAL REQUIREMENTS Labor and Site Requirements 1. Two installers. 2. An electrician is required for making all electrical connections. (See the Rytec System 3 Drive & Control Installation & Owner’s Manual.) 3. 100% accessibility to the door opening during the entire installation process. No traffic should be allowed to pass through the opening while the door is being installed. Forklift Requirements A forklift supplied by the customer, dealer, or installer is mandatory for the safe and proper installation of this door. The forklift should have: • 2,000-pound lift capacity • minimum height ability — door height, plus 12 in. • side-shift capability (desired) Electrician’s Responsibilities For complete details on the responsibilities of the electrician, refer to the Rytec System 3 Drive & Control Installation & Owner’s Manual. 2 1. Concrete saw (with water cooling attachment). 2. Water supply and garden hose. 3. Wet/dry shop vacuum. 4. 200–500 feet of 16-gauge, 19-strand, type XLPE, copper, crosslink polyethylene jacket wire (or equivalent). The size of the floor loop will determine the length of wire required. 5. Bondo P606 Flexible Embedding Sealer (or equivalent) — required to fill saw cuts in floor after the activator is installed. For cold temperature applications, Bondo P610 Speed Set must be added to the P606 to ensure the sealer cures properly. Fill-In Material Requirements Some applications may require the use of a door pullout (extension) to gain clearance of an existing obstruction between the door and the door opening. The following materials can be used to fill the space or gap between the door and the door opening. 1. 16-gauge hot-rolled sheet steel. 2. 2-in. x 2-in. x ³₁₆-in. angle iron. INSTALLATION—GENERAL ARRANGEMENT OF DOOR COMPONENTS GENERAL ARRANGEMENT OF DOOR COMPONENTS ANCHORING METHODS Figure 2 shows the location of the major components of the door and the general placement of the associated sub-assemblies for a typical installation. Correct anchoring of the side panels to the wall and the floor is important for the smooth and safe operation of the door. The wall material should be strong enough to support the weight of the door and all wall anchors. This illustration is provided to you for informational purposes only. It should not be relied upon solely during the installation of your door and its sub-assemblies. Figure 3 through Figure 6 show anchoring methods for various types of walls. Use the method that is best suited for your particular installation site. Head Assembly Serial Number Plate Located Inside One of the Side Panels Rytec Control Panel Turn Arms All necessary anchoring hardware and material required for the installation of this door is the responsibility of the door owner. If you have any questions, call your Rytec representative or the Rytec Customer Support Department at 800-628-1909. NOTE: Use ¹₂-in. diameter threaded through bolts or ¹₂-in. diameter threaded rods to anchor the door to all wall applications. Use ¹₂-in. diameter concrete anchor bolts to anchor the door to a concrete floor. Concrete, Block, or Brick Walls Fused Disconnect Concrete Wall Side Panel Side Panel Expansion Anchor Side Pipe Puralon Panels Side Pipe A1500110 Side Panel A0500005 Figure 3 Figure 2 Wood, Block, Brick, or Insulated Walls NOTE: The above illustration shows the front side of the door. Left and right are determined when viewing the front side of the door. Wood Wall Side Panel Crush Plate (¹₂-in. Thick, 6-in. x 8-in. Steel) Through Bolt or Threaded Rod A0500037 Figure 4 3 INSTALLATION—ANCHORING METHODS Insulated Walls Insulated Wall Side Panel Through Bolt or Threaded Rod A0500039 Aluminum-Clad Lumber (Front and Back Side — Full Length) Figure 5 Insulated Wall Through Bolt or Threaded Rod A0500038 Side Panel Aluminum-Clad Lumber (Back Side — Full Length) Figure 6 4 INSTALLATION—UNCRATING UNCRATING Your Rytec Door has been crated to allow for minimal handling of assemblies during the installation process. NOTE: Remove parts and sub-assemblies from the shipping crate in the order directed throughout this installation manual. 3. Remove the Puralon panels from the crate. The panels have been stacked flat with the curve side of each panel facing down, label side facing down. Once the panels are removed from the crate, store them flat with the curve side facing down. Also, protect the panels from damage. (See Figure 8.) 1. Remove the top of the crate. NOTE: The material packed on the upper level of the crate must be removed before the front of the crate can be opened. Also, the front of the head assembly faces the front of the crate. (See Figure 7.) Natural Curve Side Panels and Puralon Panels Packed in Upper Level Face Label Side Down when Storing Panels Flat Crate A1500044 Figure 8 Head Assembly, Control Panel, and Small Parts Carton Packed in Lower Level A1500001 Figure 7 2. Remove the door’s side panels from the upper level of the crate. Storing the flexible, Puralon™1 panels incorrectly can cause problems in the way the panels will seal later on. To retain the natural curvature of each panel, it is critical to store the panels in a similar manner in which they were found inside the shipping crate (curve side down). If a panel is to be rolled, flip it over and roll it with the label side of the panel facing up (curve side up). Rolling a panel against the curve or storing it incorrectly could flatten the natural curvature of the panel. NOTE: If you find it necessary to roll the panels, they must be rolled with the curve side of the panel facing up. DO NOT allow the Puralon panels to remain rolled for more than a few hours. Allowing them to remain rolled for too long, may effect the way the panels seal the opening. (See Figure 9.) To relax the panels before they are hung in place, roll them out flat and flip them over with the label facing down, curve side down. Face Curve Side of Panel Up when Rolling Up Panel (Label Facing Up) A1500045 Figure 9 4. Remove the front of the crate. 1. Puralon is a trademark of Rytec Corporation. 5 INSTALLATION—LOCATING CENTERLINE OF DOOR OPENING LOCATING CENTERLINE OF DOOR OPENING NOTE: Accurate measurements are critical for the proper installation and operation of your Rytec Door. Verify all measurements. 2. Using the centerline as a reference point, lay out and mark half of the door’s production width along the floor. (See Figure 12.) Half of Door Production Width 1. Measure the width of the door opening. 2. Divide the measurement in half to locate the centerline. Then mark the centerline along the floor. (See Figure 10.) Centerline of Opening Centerline of Opening Extend and Mark Edges of Door Along Floor A0500002 Figure 12 Overall Width of Door Opening A0500001 3. With a carpenter’s square placed against the wall, mark both sides of the door along the floor. Extend the line along each edge. Half Width of Door Opening Figure 10 LOCATING SIDE PANELS 1. The location of the side panels is determined by measuring the production width (length) of the head assembly. (See Figure 11.) 4. Check the floor for level across the door opening. The floor must be level within 0.12 in. from side-toside. If one side of the opening is higher than the other, a shim under the side panel will be required. Figure 13 and Figure 14 show two methods that can be used to ensure level side panels. NOTE: Contact the Rytec Customer Support Department if the floor is more than 2 in. out of level. Production Width Line Level Head Assembly A1500047 Figure 11 This Dimension Must Be Equal on Both Sides of Door Opening Shim Plate (As Required) A0500003 Figure 13 6 INSTALLATION—SIDE PANELS 12 in. Mounting Holes This Dimension Must Be Equal on Both Sides of Door Opening Center Water Level 12 in. Shim Plate (If Required) A0500004 Figure 14 SIDE PANELS NOTE: Holes for floor anchors have been predrilled in the bottom of each side panel. For standard panels, you must drill the holes that are necessary to bolt the panels to the wall. For insulated panels used on freezer and cooler doors, the panels come equipped with mounting lugs — for these panels, drilling is not required. 1. Drill three mounting holes in the vertical rear edge of each side panel. This is the thin sheet metal edge of the panel. The holes should be located 12 in. from the top and bottom, with one in the center. (See Figure 15.) In addition, the holes should be ¹₄ in. larger in diameter than the anchors you are using to mount the panels to the wall. This will allow room for adjusting the panels later on, once the head assembly is bolted in place. A1500012 Figure 15 IMPORTANT: It is critical to mount the side panels level and square to the wall and floor, both vertically and horizontally. A carpenter’s level and square are recommended for this procedure. 2. Locate the left and right side panels. The holes for mounting a standard panel to the floor are located along the bottom inside edge of the panel. (See Figure 16.) Threaded holes for mounting the head assembly to the side panels are located along the top inside edge of each panel. Insulated side panels have mounting lugs fitted along the inside edges for mounting the panels to the wall and floor. 7 INSTALLATION—HEAD ASSEMBLY Threaded Holes (Top) Mounting Lugs (Insulated Side Panels Only) 4. Anchor the panel to the wall and floor as required. (See “ANCHORING METHODS” on page 3.) DO NOT tighten the mounting hardware at this time. The panels may have to be repositioned once the head assembly is in place. 5. Mount the left side panel following the same procedure used for mounting the right side panel. HEAD ASSEMBLY Insulated Side Panel Floor Mounting Holes (Inside Edge) A1500013, A1500015, A1500014 Figure 16 3. Place the right side panel perpendicular to the floor as shown in Figure 17. Align the outside edge of the panel with the line indicating the production width of the door. NOTE: Place shims under and behind each panel as required. Use double-sided tape to temporarily attach the shims to the wall or side panel. 1. Remove the control panel, small parts carton, and any other items from within the crate that might block the head assembly during its removal. 2. Manually release the motor brake located on the end of the drive motor. Then, to prevent the forklift from damaging the head assembly, move the turn arms to their fully open position to allow the forks to clear the underside of the head assembly. (The turn arms are the mechanical arms that the panels will be hung from.) The head assembly must be securely fastened to the forklift before it is lifted into position on top of the side panels. Failure to safely secure the head assembly can result in damage to the assembly and cause injury to personnel. DO NOT remove the forklift out from under the head assembly until the side panels are securely fastened to the wall of the building and the head assembly is securely fastened to the side panels. Carpenter’s Level Handle the head assembly with care to prevent damage to the turn arms. Insulated Side Panel Mounting Holes Carpenter’s Square A1500048 Floor Mounting Holes Figure 17 8 Production Width Line 3. Remove the head assembly from the crate using a forklift or other suitable means. Secure the head assembly to the forks using clamps or other equivalent method. (See Figure 18.) INSTALLATION—SIDE PIPES Secure Head Assembly to Forklift NOTE: Spread Forks as Wide as Possible 2. Insert a bushing into each pivot bracket. Then attach each bracket to the side panels using the pre-drilled holes in the lower corner of each panel. DO NOT tighten the hardware at this time. (See Figure 20.) Bushing Side Panel Lock Washer Place Turn Arms in Fully Open Position Lower Side Pipe Bracket Hex Head Screw A1500049 Figure 18 4. Place the head assembly on top of the side panels with the holes in the head assembly aligned with the holes in the side panels. Bolt the head assembly to the side panels with the ⁵₈-11 x 1¹₂-in. serrated flange hex head bolts located in the small parts carton. (See Figure 19.) NOTE: On a head assembly configured for freezer use, the insulation in the head must be “notched out” to provide access to the mounting holes. Later, once the head and side panels are securely fastened, be sure to replace the insulation. Front Inside Edge of Side Panel A1500051 Figure 20 3. Slip the upper end of the side pipe over the side pipe pivot post located on the end of the head assembly. (See Figure 21.) Side Pipe Pivot Post Head Assembly Upper End of Side Pipe Serrated Flange Hex Head Bolts Hex Head Screws (Two per Side) Threaded Holes A1500050 Lock Washers (Two per Side) Side Panel Figure 19 5. Check that the side panels are plumb and square. Clamp Bracket 6. Tighten all mounting hardware on the head assembly and the side panels. SIDE PIPES A1500009 NOTE: Side pipes are required on a non-sealed panel door only. A1500008 1. Remove the two lower side pipe brackets, two bushings, four ⁷₁₆-14 x 1-in. screws, and four ⁷₁₆-in. lock washers from the small parts carton. 4. Then align the lower side pipe pivot post with the bushing in the pivot bracket and set the post in the bushing. With the side pipe in place, tighten the mounting hardware securing the pivot bracket to the side panel. (See Figure 20.) Figure 21 9 INSTALLATION—PANELS 5. Rotate the side pipe until the holes in the upper end of the side pipe line up with the holes in the pivot post. (See Figure 21 and Figure 22.) Side Panel Side Pipe Pivot Post Mount Clamp Bracket on This Side of Left Panel Direction Panel Travels Right Side Pipe Left Side Pipe Direction Panel Travels A1500052 Turn Arm Drill Hole through Sleeve and Pivot Post to Fit Roll Pin 90° Mount Clamp Bracket on This Side of Right Panel Roll Pin Figure 22 Side Pipe Flange 6. Secure the side pipe to the pivot post using a clamp bracket, two ⁷₁₆-in. lock washers, and two ⁷₁₆-14 x 1¹₄-in. screws located in the small parts carton. 7. Install the other side pipe in the manner as described above. 8. With both side pipes in place, release the motor brake and manually close the door. IMPORTANT: The door must be in the fullyclosed position before proceeding with the next step. 9. Locate the two small roll pins packed in the small parts carton. Then position the flange on both side pipes at a 90° angle to their respective side panel. 10. Drill a hole through both turn arm sleeves and side pipe pivot posts to fit the roll pins. Then drive the pins into the holes to lock the arms to the posts. (See Figure 23.) A1500016 Figure 23 PANELS The Puralon panels are mounted to the head assembly by way of a specially designed mounting bracket system. Each panel comes from the factory with a series of pre-drilled holes that run along the top edge of the panel. A flat mounting strap, with matching holes, is used to bolt each panel to its respective mounting bracket. This design allows each panel to be adjusted horizontally, side-to-side. Designed into the two center-most mounting brackets is a series of vertical slots to receive the bolts passing through the strap and panel. These slots allow the vertical angle of the two center panels to be adjusted (tilted) to the left or right. In addition, an oversized horizontal slot has been added to the two center brackets to make it easier to adjust the heavier and bulkier center panels. IMPORTANT: Follow the instructions as outlined below in the order presented. Do not cut the Puralon panels to finished length until they have all been installed and properly adjusted. 10 INSTALLATION—PANELS Each panel has been tagged with an identification number to indicate its position as it should appear when mounted on the door. The tag is located on the inside face of the curve. When facing the front side of the door, the panels (and their associated mounting brackets) are numbered from left-to-right, with panel #1 on the far, lefthand side of the door. (See Figure 24.) IMPORTANT: To ensure the door panels seal properly, it is critical that the panels be hung in their numbered order, with the natural curve of each panel facing the direction shown in Figure 24. Metal Mounting Strap Remove All Hex Nuts Puralon Panel NOTE: Leave Hex Bolts and Strap in Place. Only Remove Hex Nuts. A1500119 2 1 3 4 Figure 25 6 5 Panel Numbers Overlapping Panels A1500035 1 Front Side of Door 2 3 4 5 6 Panel Numbers Front Side of Door A1500017 2. Working from the front side of the door, left-to-right, lift each panel in place and attach it to its corresponding mounting bracket. (See Figure 26.) Make sure the number on the panel matches up with the correct mounting bracket and that the panels are hung with all mounting bolts pointing toward the back side of the door. Also, it is important that each mounting strap (and panel) is centered on its respective mounting bracket — later on, if it becomes necessary, the panels can be repositioned. Seamed Panels Figure 24 1. The metal mounting strap used to attach each panel to its respective mounting bracket has been installed on the panel at the factory. Before a panel can be installed, first remove the nuts that are threaded onto the bolts that pass through the mounting strap and panel. Leave the strap and bolts in place once the nuts are removed. (See Figure 25.) Secure Mounting Strap to Mounting Bracket Turn Arm Panel with Mounting Strap Mounting Bracket (Along Bottom of Turn Arm) A1500120 Figure 26 11 INSTALLATION—PANELS NOTE: The metal mounting straps used with the two, center-most panels each have an extralong bolt located in the center hole. This longer bolt allows you to hang these bulkier door panels on their respective mounting brackets without having to struggle with the remaining (shorter) bolts. It will also allow you to center the panel horizontally on the bracket, before the remaining bolts are installed. (See Figure 27.) Thread Nut on Extra-Long Hex Bolt First Two Center-Most Panels Uneven Overlap Uneven Overlap A1500056 Improper Panel Alignment Figure 28 Extra-Long Hex Bolt Two Center-Most Panels Panel with Mounting Strap Even Overlap A1500121 Figure 27 3. After a panel is hung in place, work the remaining bolts into the mounting bracket and then thread a nut onto each bolt. Loosely tighten all nuts to temporarily secure the panel. (Later, the nuts will be securely tightened once all the panels are adjusted level and square.) 4. Continue the above procedure for each door panel. Panel Alignment With all the panels in place, the two center-most panels can now be checked for level and square. 1. Stand far enough back from the door to visually inspect the overlap and alignment of the two center panels. They should both hang straight, with all overlaps even along the entire length of the adjoining panels. (See Figure 28 and Figure 29.) NOTE: Because the panels are shipped from the factory slightly longer than necessary, it is important that you lift (roll up) the bottom edge of each panel just enough so that it will not drag on the floor when the panels are checked for level and square. Later on, they will all be trimmed to finished length. 12 A1500057 Proper Panel Alignment Figure 29 NOTE: If a panel requires any side-to-side adjustment, it is acceptable to index that panel one hole in either direction. But repositioning a panel more than one hole could cause the extended mounting strap to bind and become damaged once the door is activated. Also, if you find it necessary to reposition a panel, it may be necessary for you to reposition the overhanging bolt to ensure that the panel is fully supported from behind by the mounting bracket. If a bolt is to be moved, you will first need to drill a new hole in the panel to fit the bolt. 2. Once the center panels are adjusted, check the position of the remaining panels. After any necessary adjustments are made, tighten each nut on every panel to secure all panels. INSTALLATION—KNOB AND ROPE TIE INSTALLATION Trimming Panels (Puralon Panels Only) Side Pipe Mounting Flange If the panels on your particular door include a Hypalon® sweep along the bottom edge, DO NOT trim the panels. IMPORTANT: For Puralon panels only: Failure to trim the panels to length will cause them to drag across the floor, which can result in the door not sealing properly. Using a utility knife, trim the bottom edge of each Puralon panel to within ¹₄-in. of the floor. To make it easier to move your knife through the material when trimming the panels to length, pull the excess material away from the blade as you make the cut. (See Figure 30.) NOTE: Over time, the Puralon panels may stretch and require retrimming. Panel NOTE: Panel Must Be Seated All the Way into Mounting Flange A1500054 Figure 31 2. Using the pre-drilled holes along the edge of each flange as a template, drill a series of holes along the outside edge of each panel. Then fasten the panels to the flanges using the ⁵₁₆-18 x 1¹₄-in. screws and nuts located in the small parts carton. KNOB AND ROPE TIE INSTALLATION Rope Tie Doors Only 1. Move the door to the fully closed position. 2. Using Table 1 below, determine how many rows of knobs and ties are required for your particular door. Table 1 Distance from Floor (Inches) Door Height (Feet) Row 1 Row 2 Row 3 Row 4 6 24 48 – – 7 24 60 – – 8 24 72 – – 9 24 72 – – 10 24 72 – – 11 24 72 – – 12 24 72 120 – Attaching Panels to Side Pipes (Side Pipe Doors) 13 24 72 120 – 1. Insert the outside edge of the two outer panels into the mounting flange of its adjoining side pipe. Make sure each panel is seated all the way into the flange. (See Figure 31.) 14 24 72 120 – 15 24 72 120 – 16 24 72 120 168 17 24 72 120 168 18 24 72 120 168 19 24 72 120 168 20 24 72 120 168 ¹₄-in. Gap between Panel and Floor A1500095 Figure 30 13 INSTALLATION—KNOB AND ROPE TIE INSTALLATION 3. Once the number of rows is determined, the next step is to lay out a column of holes along each overlapping pair of panels. For example, panels 1 and 2, 2 and 3, and so on. (See Figure 32.) Drill Holes and Install Knobs from This Side Note that each panel has a straight, vertical edge along one side and a 45° cut (or S-cut) near the top of the opposite edge. When laying out a column of holes, measure off the straight, vertical edge for all the holes in that column. The two, 1-in.-diameter holes used for each knob and rope tie are both centered 2 in. from the same vertical edge. (Refer to the Detail View in Figure 32.) Turn-Arm Hinge Panel Numbers 1 2 23 45 56 Row 4 Row 3 Row 2 Row 1 Reference Straight Edge A1500036 A1500020 Figure 33 6. Locate the nylon rope shipped in the small parts carton. To prevent fraying, wrap a short length of tape around one end of the rope. 7. Locate the small wire crimps shipped in the small parts carton. Place a crimp over the taped end of the rope and lock it in place by crimping the ends together with a side cutter or other suitable tool. NOTE: Do Not Reference Curved Edge 1-in. Diameter Hole Drill Holes and Install Knobs from This Side A1500061 A1500060 2-in. 2-in. Detail View (Not to Scale) 8. Tie a knot next to the crimp. 9. Feed the other end of the rope through the wide face of the first knob (the first knob is sandwiched between the overlapping panels with the door closed). Then feed the rope through the back of the adjoining knob in the opposite panel and pull the rope tight (with the panels closed). (See Figure 34.) Figure 32 Turn-Arm Hinge 4. Using a 1-in. hole saw or wood spade bit, drill the holes for the knob and rope ties. Each hole should be drilled from the same direction the knob will be installed. Using the turn-arm hinge for reference, drill the holes toward the turn-arm side of the panel, as shown in Figure 33. 5. Insert the small end of each knob into the hole from the side opposite the turn-arm hinge. Press each knob firmly in place. Knot Second Knob A1500021 Figure 34 14 Rope First Knob INSTALLATION—KNOB AND ROPE TIE INSTALLATION 10. To secure the rope tie, tie a knot close to the wide face of the second knob. The rope should be without slack with the door fully closed. (See Figure 35 and Figure 36.) Panel 12. Repeat the above steps for each pair of knobs. Figure 38 shows a complete set of knobs with a knot and a crimp at each end of the tie. Figure 39 illustrates a complete rope tie on both sides of the door. Crimp Knot Rope Wide Face of Knob A1500005 Knob Figure 35 A1500097 Figure 38 Rope Tie Must Be Tight with Door Closed Side Panel Correct Puralon Panel Rope Knob Incorrect TurnArm Hinge Knob A1500062 A1500041 Figure 36 11. To prevent the other end of the rope tie from fraying once it is cut to length, wrap a length of tape around the rope, near the second knot. Then cut the rope tie to length — cutting across the middle of the taped section. Install a crimp over the taped end. (See Figure 37.) Left Side Shown — Top View Figure 39 13. To prevent the Puralon panels from cutting into the rope ties as the door is opened and closed, cut (shave) a slight bevel, about 4 in. long, along the edge of each panel where it makes contact with each rope tie. (See Figure 40.) Cut 4-in.-Long Bevel along Edge of Panel Knot Tape Knob Crimp Rope Tie A1500063 Figure 37 A1500096 Figure 40 15 INSTALLATION—SEAL SEAL Side Seal Center Seal – Hypalon NOTE: A Hypalon side seal is used to close off the opening between the side panel and the outside Puralon panel. A side seal is rectangular in shape. NOTE: A center seal is used to close off the opening between two adjacent Puralon panels. A center seal is wider at the top than it is at the bottom. 1. Locate the Hypalon center seal(s). The wide end of the seal is positioned at the top. (See Figure 41.) Position Wide End at Top INSULATED SIDE PANELS AND SEALED PURALON PANELS A Hypalon side seal was factory installed on the two insulated side panels. You must attach these seals to the edge of the adjacent Puralon panel using the Velcro strips provided on the seal and panel. (See Figure 43.) Insulated Side Panel Sealed Puralon Panel Hypalon Side Seal Hypalon Seal Velcro Strips Left Side Panel — Right Is Mirror Image A1500002 A1500065 Figure 41 Figure 43 2. Attach a center seal to the edge of each adjoining Puralon panel using the Velcro®1 strips provided on the seal and panels. When attaching a center seal, start at the bottom and work your way toward the top. (See Figure 42.) STANDARD SIDE PANELS AND SEALED PURALON PANELS The Hypalon side seals used on a door having standard side panels and sealed Puralon panels are field installed. The following steps illustrate the installation procedure for the right side seal. The procedure used for installing the left side seal is the same. 1. Remove the turn-arm stop from the side panel. It is held in place by two hex head cap screws, flat washers, and serrated flange nuts. Save all hardware for later use. (See Figure 44.) NOTE: As you remove the turn-arm stops, note that the right stop is along the back side of the door and the left stop is along the front side of the door. Also note that the cap screws holding both stops in place are installed from the front side of the door. It will be critical, later on, to reinstall the stops and hardware as originally found. Hypalon Seal Puralon Panel Puralon Panel A1500006 A1500022 Velcro Strip along Edge of Seal and Panel Hypalon Seal Figure 42 1. Velcro® is a registered trademark of Velcro Industries B.V. 16 INSTALLATION—SEAL NOTE: Right Turn-Arm Stop along Back Side of Door. Left Turn-Arm Stop along Front Side of Door. Serrated Flange Nut Hex Head Cap Screw Right Side Panel Standard Side Panel Sealed Puralon Panel Face Velcro Strip on Side Seal toward Sealed Puralon Panel Side Seal A1500042 Figure 46 Flat Washer Right TurnArm Stop 3. Drill two ³₈-in. holes in the side seal. The holes must align with the holes in the side panel that are used for mounting the turn-arm stop. (See Figure 47.) A1500105 Figure 44 2. Locate the side seal and attach it to the side panel using the bolting bar and the self-tapping screws provided in the small parts carton. (See Figure 45.) Make sure to position the seal so that the Velcro strip along the back edge is facing the sealed Puralon panel. (See Figure 46.) Drill ³₈-in. Holes in Side Seal to Line Up with Holes in Side Panel Side Panel Side Seal Side Seal A1500109 Self-Tapping Screw Figure 47 Side Panel Bolting Bar A1500108 Figure 45 4. Reattach the turn-arm stop as it was originally found using the saved hardware. Face the rubber bumper on the stop toward the center of the door. (See Figure 44.) 5. Repeat the above procedure for the left side seal. 17 INSTALLATION—PANEL CLEANING FREEZER DOOR SIDE SEAL PANEL CLEANING NOTE: A Hypalon side seal is used to close off the opening between the side panel and the outside Puralon panel. Once the panels and seals are in place, clean the panels with a general household surface and glass cleaner. Avoid scratching the panels by using a clean, soft cloth. Locate the side seal and attach it to the side panel using the clamp strip and self-tapping screws provided in the small parts carton. (See Figure 48 and Figure 49.) DOOR SEALING Caulk the side panels and the head assembly where they meet the wall of the building. MANUAL BRAKE RELEASE (OPTIONAL ITEM) Front of Door If the door is equipped with a manual brake release kit, there will be a cable attached to the brake release handle that is located on the end of the motor. Tie the cable out of the way of traffic using a cable clamp or other suitable method. Hypalon Side Seal DEFROST SYSTEM (FREEZER DOOR OPTION) Thermal Break Self-Tapping Screw Heat Lamp Fixture Installation NOTE: On cold-side mounted doors, the heat lamp fixtures were factory installed on the door head assembly. For all other doors, the fixtures are installed in the field. 1. Turn off power to the door. Clamp Strip Side Panel A1500100 The disconnect must be in the OFF position and properly locked and tagged before performing the following procedure. Figure 48 Hypalon Side Seal 2. Bolt the left and right front-mount heat lamp support brackets to the sides of the head assembly. Use the ⁷₁₆-in. x 1-in. hex head screws, lock washers, and flat washers provided. (See Figure 50.) Head Assembly Thermal Break Head Assembly Hex Head Screws Side Panel Self-Tapping Screw Side Panel Clamp Strip A1500025 A1500114 Figure 50 Figure 49 18 Front-Mount Heat Lamp Support Bracket INSTALLATION—DEFROST SYSTEM (FREEZER DOOR OPTION) 3. Install a triangular heat lamp fixture bracket on both ends of each lamp fixture. Use the 10-24 x ³₄-in. hex head screws, lock washers, and hex nuts provided. (See Figure 51.) 5. Install the front-mount heat lamp angle (with fixtures) to the end of the support brackets that were mounted earlier. Use the ³₈-in. x 1¹₄-in. hex head screws and serrated flange nuts provided. (See Figure 53.) Hex Nut Lock Washer Front-Mount Heat Lamp Angle Heat Lamp Fixture Bracket Hex Head Screw Heat Lamp Fixture Serrated Flange Nut A1500111 Figure 51 4. Attach the heat lamp fixtures to the front-mount heat lamp angle using the ³₈-16 x 1-in. hex head screws and serrated flange nuts provided. DO NOT install the lamp bulbs or red sleeves at this time. (See Figure 52.) Front-Mount Heat Lamp Angle Serrated Flange Nut Screw Heat Lamp Fixture A1500026 Hex Head Screw Figure 53 Lamp Fixture Wiring and Bulb Installation The disconnect must be in the OFF position and properly locked and tagged before performing the following procedure. Wire all heat lamp fixtures according to the schematic that was shipped with the control panel, following all state and local codes. The necessary conduit, junction box, and wiring are to be supplied by the owner of the door. Route the wiring from the lamp fixtures to the junction box as shown. (See Figure 54.) Head Assembly A1500028 Figure 52 Junction Box Heat Lamp Fixture A1500027 Wiring Figure 54 19 INSTALLATION—DEFROST SYSTEM (FREEZER DOOR OPTION) LAMP BULB AND RED SLEEVE INSTALLATION Never touch the glass surface of the lamp bulb or the red sleeve with your bare fingers, and never handle them with a dirty or oily rag. Any debris or oil on the surface of the lamp will lead to a “hot spot,” which will reduce the life of the lamp and even cause it to immediately fail. With the lamp fixture(s) mounted, a lamp bulb and red sleeve can now be installed in each fixture. 1. Remove the end cover plates from the lamp fixture. (See Figure 55.) 4. Connect the wire on the ends of the lamp to the screw terminal located at each end of the fixture. (See Figure 56.) Leave a ¹₄-in. loop on the end of the wire as shown in Figure 56. If the loops are not made, the bulb can become damaged when the fixture expands as a result of the heat output from the lamp. Lamp Fixture (Cover Removed) Wire on End of Lamp ¼-in. Loop Lamp Fixture Screw Terminal Lamp Bulb Lamp Bulb with Red Sleeve A1500098 Figure 56 Red Sleeve 5. After the lamp bulb is wired in place, cut off the excess wire leading away from each screw terminal. 6. Reattach all end cover plates. Screw End Cover Plate A1500067 Lamp Fixture Adjustment (Warm-Side and ColdSide Mounted Doors) Figure 55 2. Locate the lamp bulb and the red sleeve. 3. Slide the sleeve over the lamp and install the lamp in the fixture. (The sleeve blocks most of the radiant visible and ultra-violet light from the lamp, but it does not affect the radiant heat output.) The disconnect must be in the OFF position and properly locked and tagged before making the following adjustments. Excessive heat can severely damage the Puralon panels. 1. Turn off power to the door. 2. To redirect a heat lamp, first loosen the nuts that lock the lamp fixture in place. 20 INSTALLATION—DEFROST SYSTEM (FREEZER DOOR OPTION) 3. Direct the heat lamp fixture(s) to aim at the area of the floor where the panels of the door meet the floor. (See Figure 57 through Figure 60.) Heat Lamp Fixture Figure 57 and Figure 59 show the correct method for aiming a lamp fixture. Figure 58 and Figure 60 show the incorrect method. Heat Lamp Fixture Aim fixture toward area of floor where Puralon panels meet floor (allows warm air to rise across entire face of door). Aim fixture toward area of floor where Puralon panels meet floor (allows radiant heat to rise across entire face of door). A1500029 Warm-Side Mounted Door Correct Angle to Aim Lamp Fixture Figure 57 A1500032 Cold-Side Mounted Door Correct Angle to Aim Lamp Fixture Figure 59 Damage to panel can result if lamp fixture is aimed directly at panel. Damage to panel can result if lamp fixture is aimed directly at panel. Aiming lamp fixture straight down will have no affect on defrosting the door. Aiming lamp fixture straight down will have no affect on defrosting the door. A1500030 Warm-Side Mounted Door Incorrect Angle to Aim Lamp Fixture A1500034 Cold-Side Mounted Door Incorrect Angle to Aim Lamp Fixture Figure 60 Figure 58 21 INSTALLATION—DEFROST SYSTEM (FREEZER DOOR OPTION) Heat Lamp Controls If your door is equipped with heat lamps, they are controlled by the control panel. Refer to the Rytec System 3 Drive & Control Installation & Owner’s Manual. With the defrost system in the MANUAL mode, the heat lamps will immediately power up. When in the AUTO mode, the heat lamps are operated automatically by the control system. An automatic timer function can be set to periodically cycle the lamps on and off. Placing the defrost system in the OFF mode turns off the lamps and disables the automatic timer function. Blower Controls BLOWER SPEED If your door is equipped with a blower (unheated or heated), the blower fan speed has four modes of operation (OFF, LOW, HIGH, and AUTOMATIC). Refer to the Rytec System 3 Drive & Control Installation & Owner’s Manual. With the blower switch in the AUTOMATIC position and the door closed, the blower will run at low speed. When the door is open, the blower will operate at high speed. With the blower switch in the HIGH or LOW position, the blower will run at high or low speed regardless of the position of the door. The blower speed you select (LOW, HIGH, or AUTOMATIC) will depend on the environmental conditions (temperature, humidity, etc.) of the installation site. Placing the switch in the OFF position will override the control system and prevent the blower from turning on. BLOWER HEATER If the blower is equipped with an internal heater (heated blower), the heat level is controlled by the control panel. Refer to the Rytec System 3 Drive & Control Installation & Owner’s Manual. The standard heated blower has two heating levels. An optional heated blower is available with three heating levels. The heat level you select will need to be set according to the environmental conditions of the installation site. Hard-Panel Door If an optional, hard-panel door is installed with your Rytec Door, the defrost system must be controlled by a limit switch installed on the hard-panel door to prevent heat build-up between the two doors. (“Hard-Panel Door Remote Limit Switch (Mandatory Item if Hard-Panel Door Is Installed)” on page 24.) 22 If an optional, hard-panel door is installed with your Rytec Door, a limit switch to override the defrost system must be installed on the optional door. When installed in accordance with the schematic that was shipped with the door, the limit switch will allow the defrost system to turn on only when the hard-panel door is in the fully open position. FIN ADJUSTMENT All blowers are equipped with air deflection fins in the heat vent that runs along the bottom of the blower unit. To redirect the airflow, loosen the nuts that lock the fins in place and reposition the fins as necessary. Tighten the nuts to lock in the adjustment. (See Figure 61.) Blower Unit Air Deflection Fins Adjustment Nut A1500007 Figure 61 Figure 62 shows the correct angle to direct the airflow for a standard blower. Figure 63 shows the correct angle to direct the airflow for a Rytec bottom intake (RBI) blower. INSTALLATION—ELECTRICAL SYSTEM ELECTRICAL SYSTEM Standard Blower NOTE: Refer to the Rytec System 3 Drive & Control Installation & Owner’s Manual for electrical system wiring. Door Close and Open Limit Position The door should open and close completely, without traveling beyond the limits in either direction. Improperly adjusted open and close limits can result in damage to the drive system. Aim heat vent fins toward area of floor where Puralon panels meet floor. NOTE: To set the close and open limits, refer to the Rytec System 3 Drive & Control Installation & Owner’s Manual. CLOSE LIMIT 1. Turn on the power and close the door. Cold-Side Mounted Door Correct Angle to Aim Standard Blower A1500154 2. Check the spacing between each door panel. If the door is not closed completely, the leading panels will have a gap between them. If the door is closed too tightly, the rubber bumpers on the turn arms will be compressed. (See Figure 64.) Figure 62 Rytec Bottom Intake Blower (RBI) Turn Arm Turn Arm Direct heat vent fins straight down to ensure air intake pulls return air across entire face of panel. A1500004 Puralon Panel Bumper Hypalon Seal Puralon Panel Figure 64 NOTE: To check if the door has closed too far, perform the following procedure. A1500153 Cold-Side Mounted Door Correct Angle to Aim RBI Blower 3. With the door closed, turn off the power and manually release the brake. If the door springs back toward the open direction as the brake is released, the door is closing too far and the close limit should be readjusted. Refer to the Rytec System 3 Drive & Control Installation & Owner’s Manual. Figure 63 23 INSTALLATION—ELECTRICAL SYSTEM OPEN LIMIT 1. Turn on the power and open the door. 2. Check that the door is in the fully open position. If the door is not open all the way, the leading panels will be inside the door opening. If the door is open too far, the rubber bumpers between the turn arms will be compressed. (See Figure 65.) Hard-Panel Door Remote Limit Switch (Mandatory Item if Hard-Panel Door Is Installed) The disconnect must be in the OFF position and properly locked and tagged before installing the remote limit switch. Turn Arm Excessive heat can severely damage the Puralon panels. If a hard-panel door is installed with your Rytec Door and the defrost system (heat lamps or blower) is located between the two doors, the defrost system must be turned off any time the hard-panel door is not in the fully open position to prevent heat from building up between the two doors. To automatically control the defrost system, a remote limit switch must be installed and located as shown in Figure 66. Bumper Puralon Panel A1500003 Figure 65 NOTE: To check if the door has opened too far, perform the following procedure. 3. With the door open, turn off the power and manually release the brake. If the door springs back toward the close direction as the brake is released, the door is opening too far and the open limit should be readjusted. Refer to the Rytec System 3 Drive & Control Installation & Owner’s Manual. 1. Locate the remote limit switch in the small parts carton. If a remote limit switch (Rytec part number 0-114-031) was not included with your door, contact the Rytec Customer Support Department. 2. Mount the remote limit switch so that the hard-panel door will actuate the limit-switch only when the hard-panel door is in the fully open position. Install the limit switch using the track provided or other suitable mounting method. The installation of this switch may vary from one application to another. Consult the factory if you have any questions. Figure 66 shows the general layout of the remote limit switch. Fast-Fold Door Wall Remote Limit Switch A1500112 CAUTION: Locate remote limit switch so that defrost system will power up only when hard-panel door is in fully open position. Figure 66 24 Hard-Panel Door (Shown in Fully Open Position) INSTALLATION FINAL CHECKS NOTE: Check all of the following door components and systems once the door panel has been cycled at least 20 times. Side Panels: Check that side panels are plumb and square and that all anchor bolts are secure and tight. Head Assembly: Check that all mounting hardware is in place and tight. Door Panels: Check that all door panels are installed properly, hanging straight, and travel smoothly as described in “PANELS” on page 10. Make sure all hardware is in place and tight. The panels should be kept trimmed to within ¹₄-in. of the floor as described in “Trimming Panels (Puralon Panels Only)” on page 13. Because the panels can stretch over time, failure to keep them trimmed to length could result in a door that seals poorly. Knobs and Rope Ties: All knobs and rope ties should be installed correctly as described in “Knob and Rope Tie Installation” on page 13. Seals: All seals should be installed correctly, as described in “SEAL” on page 16. Side Pipes (Non-Sealed Panel Doors Only): Both side pipes should be installed with a roll pin as shown in Figure 23. The outer Puralon panels should be bolted to the side pipes. Close and Open Limits: Adjusted properly. Side-toside travel of the door should be as described in “Door Close and Open Limit Position” on page 23. Motor: Check that the door travels in the proper direction when the button is pressed. Timers: Automatic timers must be set to ensure that the door closes properly, as described in the Rytec System 3 Drive & Control Installation & Owner’s Manual. Activators: Operate as specified by manufacturer. Caulk: Be sure that the side panels and head assembly are caulked where they meet the wall of the building. Freezer Doors: Check the defrost system for normal operation and adjust as required. If an optional hardpanel door is used, verify that the remote limit switch allows the defrost system to power up only when the hard-panel door is in the fully open position. Check all controls for proper operation. 25 NOTES 26