IMPORTANT NOTICE Interbath
Transcription
IMPORTANT NOTICE Interbath
IMPORTANT NOTICE This document MUST be forwarded to your architect or building contractor to ensure that the site is prepared correctly as any mistakes could be extremely costly. Pre-Installation Document Interbath General Site Requirements. The wall decoration and floor covering must be complete and finished. Positioning and fixing the unit. The Interbath stands on and is secured to the floor. Floors must have sufficient depth in order to receive 50mm long anchors. Under-floor heating CANNOT be laid under the bath area. Adjacent walls need to be plumb, flat and clear of obstructions up to 1220mm above the floor. Skirting boards may be left in place. Fig 1 If the unit is to be installed in an alcove or into a corner the side wall/walls will also have to be clear for a height of 1220mm. The bath can be fitted as a Corner unit, Peninsular unit or an Island unit. In all configurations a minimum clearance of 850mm must be left on the door side for access. A minimum clearance of 40mm is required against any adjacent walls (WG & LWG) and fixed appliances (FG) including toilets, radiators, sinks and shower units. Note: If the bath(corner fitting) is ordered with neatfold stretcher, the gap at the long side of the bath (LWG) would have to be 65mm. If a Peninsular or Island layout is required with a neatfold stretcher there must be enough clearance for the stretcher to swing and fold to the side of the bath, 400mm minimum on the opposite side to the door. Fig 1 LWG FG WG Bath length Page 850mm FG Positioning and fixing the unit - Continued Fig 2,2a and 2b When calculating the footprint of the bath use the diagram below and ensure the clearances are provided at the ends and at the sides. The red shaded areas must be kept clear of any pipework, wiring or underfloor heating above and below the floor. The floor must be strong enough (especially in the foot areas) to carry the weight of the bath when full and occupied. NOTE: Floors must be flat and level in the area where the bath is to be installed. If this is not possible Astor Bannerman MUST be informed prior to installation. Fig 2 Available bath lengths 1710/1910/2110/2310mm Bath length 1710 = 660mm Bath length 1900+ = 890mm 40 mm minimum clearance at each end 290mm 40 mm minimum clearance at each side Indicates electrical outlet = = No obstructions can be laid in these areas 800 540 mm mm Hot and cold ball type isolation valves and 40mm waste to be fitted in the green area 250 mm CL 1050mm 760mm 1220 mm 470mm 1 280mm min 240 mm 180mm 2 3 25min Fig 2a Fig 2b 50mm Anchor depth 290mm 6 anchors in each footplate 540mm Each footplate is fixed to the floor as shown. Page Plumbing Options Fig 3 The plumbing options and the outlet positions of the water and waste services must be at the tap end of the bath. 22mm ball type isolation valves (V) should be positioned and orientated exactly as shown but can be fed through the wall, floor or along the wall from either side. See Fig 5. Fig 3 View looking from tap end 220mm Centres = = V 200mm Floor to Centre H C W Fig 4 A 40mm waste pipe (W) is required and should be positioned and orientated exactly as shown but can be fed through the wall, floor or along the wall from either side. Fig 4 Through Floor Waste Option 125mm wall to centre of 40mm waste pipe Through Wall Waste Option 100mm wall to end of 40mm waste pipe 100mm wall to end of valve VALVE H VALVE C Page Plumbing Options Continued. Fig 5 and 6 If the water sevice pipes need to be fitted along the wall from a side wall they need to be kept tight against the wall. The water service pipes can be offset vertically (V and Vo) providing the centre of the top pipe is no more than 200mm from the floor. If the waste is to be fed along the the wall from a side wall it must be kept tight to the wall and be positioned below the water service pipes. The 40mm waste pipe can be fed through the wall (WW) or floor (WF) as shown and cut to the lengths indicated. Fig 5 Fig 6 2 different waste options WW V SW 100mm Vo WF 200mm VALVE 100mm VALVE 125mm SF 15mm REDUCER 22mm Note: If the site piping is 15mm then this should be expanded to 22mm piping at the valve end to accommodate the valves. VALVE Tap Options The Interbath can be supplied with various tap/mixer sets. The minimum water pressure on each supply must be 1 bar and a maximum of 10 bar with a differential of no more than 5 bar. Equal Pressures are recommended. Page Electrical Connection. Fig 7 & 8 The bath requires a 1 off 230 volt, 1.25kW, waterproof flex outlet, located at any of the positions shown and supplied from a protected fused spur. Fig 7 A waterproof surface mounted, protected flex outlet with a 20mm gland fitted at the bottom is required in one of the positions shown 100mm 180mm Fig 8 180mm 100mm Page Technical Information. Electrics A.C. Input 220 - 240V~, 50/60Hz, 1.25kW Maximum. DC Output, 24v, 8 Amps. Safe Working Load 300 Kilograms Test Load 375 Kilograms Length 1725mm. 1925mm. 2125mm. 2325mm. 1805mm 2005mm 2205mm 2405mm Width 800mm required required required required to to to to provide provide provide provide minimum minimum minimum minimum clearance. clearance. clearance. clearance. 1690mm required to provide minimum clearance including the clearance for the door. Height Range 760mm Minimum 1220mm Maximum. Bath Water Capacity Interbath 170 Interbath 190 Interbath 210 Interbath 235 230 256 283 317 litres litres litres litres to to to to the the the the overflow. overflow. overflow. overflow. Water Pressures A Minimum of 1 bar is required on both Hot and Cold water supplies. Maximum 10 bar. Maximum differential between Hot and Cold 5:1. NOTE: If the Interbath is ordered with an additional waste outlet then an View looking extra from waste tap endpipe is required (DW). The two waste pipes should be positioned 50mm either side of the centreline of the bath orientated as shown for a single waste pipe. 220mm Centres = = V 200mm Floor to Centre C H DW Technical Helpline - Direct Telephone Number - 01242 822972 Page Unit 11f, Coln Park Andoversford Gloucestershire GL54 4HJ Tel 01242-820820 Fax01242-821110 e mail: sales@astorbannerman.co.uk VAT Reg No. 630609068