Cold Climate Experiences in Stor
Transcription
Cold Climate Experiences in Stor
Cold Climate Experiences in Stor-Rotliden Daniel Gustafsson, Måns Håkansson Kalle Blomberg, Jan-Åke Dahlberg, Peter Krohn, Sven-Erik Thor Confidentiality class: Medium (C2) Cold Climate Experiences in Stor-Rotliden Confidentiality class: None (C1) Basics • • • • • • • • Installed capacity 78MW Number of turbines 40 Supplier Vestas V90 1.8 (11) and 2.0 MW (29) Expected annual production 229 GWh Investment cost 1.5bSEK Building and Construction spring 2009 to fall 2010 Last machine was grid connected November 16th Located in Åsele Community • No de/anti icing equipment • Equipment to detect vibrations • Ice sensors will be mounted Confidentiality class: None (C1) Location Confidentiality class: None (C1) Google Earth Confidentiality class: None (C1) Details Confidentiality class: None (C1) Confidentiality class: None (C1) Confidentiality class: None (C1) Confidentiality class: None (C1) Icing event 2010 Confidentiality class: None (C1) How do we detect ice • Several ice sensors in the met mast • Holooptics icing rate sensors will be installed on six nacelles, during 2011 • Vibration sensors have trigged a number of automatic stops • Power curve deterioration observed at several locations Confidentiality class: None (C1) Ice Measurements started 2009 (on-going) IceMonitor Confidentiality class: None (C1) Holooptics Sensors in mast Confidentiality class: None (C1) Challenge to analyze icing situations [ °C, m/s ] 20 [g] Stor-Rotliden 15 8000 7000 Temp mastfot °C Wind speed m/s T26 accu IceMonitor g 10 6000 5 5000 0 4000 -5 3000 -10 2000 -15 1000 -20 0 2009-11-01 00:00 Confidentiality class: None (C1) 2009-11-04 00:00 2009-11-07 00:00 2009-11-10 00:00 2009-11-13 00:00 2009-11-16 00:00 2009-11-19 00:00 2009-11-22 00:00 2009-11-25 00:00 . Ice measurement data 2010 Stor Rotliden [ °C, m/s] [g] 4000 20 Temp mastfot °C Wind speed m/s IceMonitor g 15 3500 10 3000 5 2500 0 2000 -5 1500 -10 1000 -15 500 -20 0 2010-11-11 00:00 2010-11-15 00:00 2010-11-19 00:00 2010-11-23 00:00 2010-11-27 00:00 2010-12-01 00:00 2010-12-05 00:00 . Confidentiality class: None (C1) Anemometers at nacelle Confidentiality class: None (C1) Anemometers at nacelle Confidentiality class: None (C1) Additional measurements 2011 partly financed by Vindforsk • Title ”Icing – complementary work to V-313” • Application near approval • Sensors: - Three NRG Labkotec Goodrich Camera Confidentiality class: None (C1) Assessment of power performance in Stor-rotliden Confidentiality class: None (C1) Stand still in % of total time Stand still in % of total time 12 10 Total stand still 8 % Possible ice occurence 6 4 2 0 October November December Disclaimer: These results were obtained when the wind farm was in commissioning phase and may not be representative for ”real life” operation Confidentiality class: None (C1) Energy losses due to stand stills Energy losses in % of total production (stops only) 12,0 Total Losses Due to ice? % 8,0 4,0 0,0 October November December Disclaimer: These results were obtained when the wind farm was in commissioning phase and may not be representative for ”real life” operation Confidentiality class: None (C1) Performance of C11 using the mast anemometer 2200 2000 1800 1600 Power kW 1400 1200 Below zero Above zero 1000 800 600 400 200 0 -200 0 Confidentiality class: None (C1) 2 4 6 8 10 12 Wind Speed (Mast 60m x 1.15) 14 16 18 An example of performance in CC 2200 2000 1800 1600 Power kW 1400 1200 WP-Level 0 - Mode 0 - 07-2009 > 0, Median (Mast) < 0, Median (Mast) 1000 800 600 400 200 0 -200 0 2 4 6 8 10 12 Wind Speed (Mast 60m x 1.15) Confidentiality class: None (C1) 14 16 18 Discussion and conclusions Preliminary results - Data from commissioning period - Only part of a winter season analyzed - Fairly simple analysis methodology - Data quality to some extent questionable Conclusion - Significant production losses… - Further analysis are to be carried out after this winter season Invitation to co-operation - Open to all suggestions for information and data exchange Confidentiality class: None (C1)