50% CD Theatrical Cu..

Transcription

50% CD Theatrical Cu..
ETC
Element Control Console
®
™
Eos Series
®
G E N E R A L I N F O R M AT I O N
O R D E R I N G I N F O R M AT I O N
Designed for venues using primarily conventional lighting, the
Element control console provides the powerful features of the
Eos system in an economical and simplified package. In addition
to keypad commands, True LTP Channel Faders provide hands-on
control of intensity and can be used to set manual levels and edit
recorded cues and submasters. On Demand Moving Light Controls
are available to facilitate using conventional accessories like moving
mirror heads, color scrollers or gobo rotators, or to make controlling
small numbers of moving lights simple and direct.
Element
™
Element Console, 40 Faders, 250 Channels
LMNT-40-500
Element Console, 40 Faders, 500 Channels
LMNT-60-250
Element Console, 60 Faders, 250 Channels
LMNT-60-500
Element Console, 60 Faders, 500 Channels
T wo universes of DMX512-A output are available at the console via 5-pin XLR, or
these universes may be distributed with ETCNet2 DMX Nodes or Net3 DMX/RDM
Gateways. Gateways and network equipment must be purchased separately.
Element Accessories
MODEL
DESCRIPTION
Net3 RFR
Net3 Radio Focus Remote
Net3 RVI
Net3 Remote Video Interface (Element supports
Mirror Mode* operation only)
Net3 RFR-RX
Net3 Radio Focus Remote, Receiver Only
Net3 RFR-TX
Net3 Radio Focus Remote, Transmitter Only
M231
19” LCD touch screen monitor (1280x1024)
*Mirror Mode provides remote display and paging of the same screens that are
displayed on the console itself. There is no additional interaction with the console
allowed in Mirror Mode. Computers running Element Offline may be connected to
the Element console via Ethernet as a Mirror Mode Client without the need for any
additional security hardware keys.
™
®
®
DESCRIPTION
LMNT-40-250
ETCNet2 or Net3 are distributed using Net3 Gateways, which provide DMX, MIDI/
SMPTE Time Code and switch-closure functionality. MIDI In/Out is also available
locally at the console.
APPLICATIONS
• Theatre
• Television Studios
• Houses of Worship
• Corporate Theatre
• Exhibits
• Special Events
• Touring
FEATURES
• 1024 Outputs
• 250 or 500 Channels
• 40 or 60 Fader versions, pageable as channel or
submaster control
• Master Playback pair with 60mm faders, Go, Stop/Back
• Intensity, Focus, Color and Beam Palettes
• Stepped, Relative and Absolute Effects
• Hue+Saturation Color Picker and Gel Picker for LED, CMY
color mixing
• ETCNet2 , Net3 /ACN, ArtNet and Avab UDP network
protocols
• Show import from Obsession , Express , Expression ,
Emphasis , Congo and Strand 500/300 Series via ASCII
• I/O: local DMX512-A (2 output ports), MIDI In/Out, Ethernet
• Distributed DMX, MIDI, SMPTE and contact closure via
Net3 Gateways
™
MODEL
®
®
SHIPS WITH:
• Dust Cover
• Mouse and Mousepad
1 of 4
ETC
Element Control Console
®
™
Eos Series
®
S P E C I F I C AT I O N S
S P E C I F I C AT I O N S
SYSTEM CAPACITY
• 1024 Outputs/Parameters
• 250 or 500 Channels
• 10,000 Cues
• 1 Cue List
• 4 x 1000 Palettes (Intensity, Focus, Color, Beam)
• 1000 Groups
• 1000 Effects (relative, absolute or step)
• 1000 Macros
• Supports two external DVI monitors or one VGA monitor with
a minumum of 1280x1024 resolution, which may also be
touch screens
• Hard Disk
• USB ports for flash drives, pointing devices, keyboards
DISPLAY FUNCTIONS
• All show data may be viewed on one or two external
monitors. Views may be expanded across both from easily
accessed front panel controls
• The Central Information Area accesses:
-- Browser
-- File Management
-- System Setup
-- Network Configuration
-- Show Data Utilities
-- Printing
-- Record Target Lists
-- Patch functions
-- Help
-- Hue and Saturation Color Picker and Gel Picker
-- On Demand Moving Light Controls
-- Electronic alpha keyboard
-- Command Line
-- Selected Cue
-- Error messages and advisories
• Channel Displays
-- Live channel summary or table view
-- Blind cue, palette and submaster views, in list, channel,
table and spreadsheet formats
-- Flexi-channel to determine which channels to display
-- Zoom allows user to define how many channels are viewed
-- Color coded intensity levels indicate direction of move
-- Color coded non-intensity levels indicate change from
previous state
-- Graphic differentiation of moving lights, single parameter
devices, unpatched channels and deleted channels
• Patch Views
-- Patch by channel
-- Patch by address
-- Assign proportional patch value, curve, preheat value
for intensity
-- Swap pan and tilt
-- Invert pan and tilt
-- Custom fixture editor
• Playback Status Display
-- Graphic representation of cue list status, past and
future cues
• Cue List Index
• Effect Editor
• Group Editor
• Park Display
• Fader Display
-- Isolates display to active output by fader contribution
• Dimmer Monitoring
PLAYBACK CONTROLS
• Master Playback crossfade pair with two 60mm
potentiometers, Go, Stop/Back and Load buttons
• Grand Master with Blackout
• Playback fader controls include:
-- Timing Disable
-- Off
-- Release
-- Manual Override
-- Rate
• A maximum of 300 submasters (additive or inhibitive) via
integral faders
MOVING LIGHT CONTROLS
• On Demand Moving Light controls include labeling and
current parameter value on connected display monitor
• Flip and Home functions
• Parameters selectable on screen for mouse-based or touch
screen control or command line actions
2 of 4
ETC
Element Control Console
®
™
Eos Series
®
S P E C I F I C AT I O N S
S P E C I F I C AT I O N S
----------
Auto-mark
Block at cue, intensity or parameter level
Follow times
Out of sequence link
Loop functions
Preheat enable
20 part multi-part cues with default part assignment
Cue level rate override
Up to 99 decimal cues between each two whole
numbered cues
-- Execute List
·· Triggers macros with delay
·· Show control triggers
·· Analog triggers
-- Update and Update Trace functions
-- Undo record and delete
• Submasters
-- Additive, inhibitive or effect submasters
-- Bump button timing to fade up, dwell and fade out
-- Exclusive and Shielded modes
-- Faders as progress controller or intensity master
-- Bump button to mark NPs
-- Independent status
• Curves
-- Assignable in patch to modify dimmer output ramp
-- Assignable at cue or cue part level to modify intensity
crossfade profle or non-intensity parameter ramping
INTERFACES
• 2 DMX-512 Ports (RDM ready)
• Ethernet (ETCNet2 , Net3 ,Artnet and Avab UDP protocols)
• Contact Closure triggers via D-Sub connector
• 2 DVI video connectors support two external DVI displays
(1280x1024) with optional touch screen control
• 1 - VGA connector
• USB Multi-purpose (minimum 5 ports)
• Phone Remote
• Net 3 Radio Focus Remote
• MIDI In/Out (Timecode, Show Control)
• Additional MIDI/SMPTE Timecode, Show Control through
Net3 Gateway
• Additional contact closure (12 analog inputs, 12 SPDT contact
outputs, RS-232) through Net3 Gateway
ELECTRICAL
• AC input (100-240V at 50/60 Hz)
• 2 amps at 120V or 1 amp at 240V maximum power
consumption
MANUAL CONTROL
• Channel selection from keypad
• Lists constructed with +, -, thru
• Intensity set with level wheel, keypad, “full” and “out”
• True LTP channel faders for direct hands-on intensity control
• Ordered groups
• Offset, including even, odd, random, reverse
• Sneak
• Remainder Dim and restore
• Home by parameter, parameter category or all
non-intensity parameters
• Park at level
• Scaled park for temporary percentage adjustment
• Recall from and Copy to commands
• About provides detailed view of selected channels or
record targets
• Undo manual control, record, update and delete operations
• Lamp controls to strike, douse, calibrate fixtures
PROGRAMMING FEATURES
• Channel Functions
-- Non Intensity parameters set via numeric entry or
On Demand Moving Light Controls
-- Color matching to gel selector or Hue/Saturation
color picker
• Palette Functions
-- Record and Update functions
-- Toggle display to absolute data
-- Up to 99 decimal values may be inserted between any two
whole numbers
-- Selective store to refine contents of record targets
• Effects
-- Create live or blind
-- Pattern based relative dynamic effects
-- Absolute effects
-- Step effects
-- Cycle time, trail and grouping determine channel
distribution and behavior when moving through effect
-- Duration of infinite, a specific amount of time or number
of passes through pattern
-- Effect attributes to modify basic behavior
-- Cue Level Overrides to modify size, rate and form
-- Multi-part effects easily synchronize parameter activity
-- Entry mode determines how parameters enter effects
-- Exit mode determines how parameters depart effects
• Cue Recording
-- Record tracking or cue-only
-- Autoplayback recorded cues
™
3 of 4
™
ETC
Element Control Console
®
™
Eos Series
®
PHYSICAL
Element Console Dimensions
Element Console Weights
*
MODEL
Element
Console
HEIGHT
*
WIDTH
DEPTH
inches
mm
inches
mm
inches
mm
5.1
130
32.9
836
17.9
455
MODEL
Element Console
WEIGHT
SHIPPING WEIGHT
lbs
kgs
lbs
kgs
30
13.6
37.5
17
*Weights and dimensions typical
17.9”
455 mm
32.9”
836 mm
5.1”
130 mm
Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736
London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0) 20 8896 1000 • Fax +44 (0) 20 8896 2000
Rome, IT • Via Pieve Torina, 48, 00156 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486
Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00
Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325
Web • www.etcconnect.com • Copyright©2011 ETC. All Rights Reserved. All product information and specifications subject to change. 4330L1003 Rev F Printed in USA 04/11 4 of 4
ETC
Connector Strips
Distribution Series
O R D E R I N G I N F O R M AT I O N
Prefix +
Length
99 + L
Quantity of Connector Connector
connector
Type*
Mounting
Q
1,2,3...
Amp
rating
C
M
@A
(A) U-ground (P) Pigtail optional (B) Stage pin (O) Outlet default
20amp
(C) Twistlock
(D) DMX
Quantity
of circuit
Terminal
location Hanger
X
1,2,3...
T
H
(R)ight
See
(L)eft hanger
(C)enter page
* For outlets not listed, use manufacturer's part number (must be UL listed).
Basic model numbering
99L-QCM/X-T-H
This is the basic form of the model number. It reads: 99 Length; Quantity; of
Connector; Mounting (pigtail or panel); on X number of circuits; Terminal location;
Hanger bracket type.
Example: 9940-16BP/8-R-21. This is a connector strip (99) forty feet long with
sixteen stage pin pigtails wired on eight circuits, terminals located on the right of
the open side of the connector strip with type 21 hanger brackets.
Additional standard connector types
S P E C I F I C AT I O N S
CONNECTOR
STRIPS
18-gauge steel construction (14 ga. end caps
and junction brackets for increased strength)
Designed for easy shipment, installation,
and service
Available with DMX outlets (for scroller and
moving light control)
Finished with textured black-powder coat
(other colors available)
Shipped standard 6’ lengths, completely
wired through and folded; splicing hardware
included (optional 12’ or 18’ factory assembled
solid lengths are available)
Standard and custom lengths and circuitry
are available
Individual circuits can have multiple outlets
Panel mount outlets or pigtail connectors
20 amp parallel-blade (Edison)(type A)
20, 50 or 100 amp grounded stage pin (type B)
20 amp Twist-lock® (type C)
Multipin and other connectors available on
request (i.e., VSC, Pyle National, 30 amp stage
pin, 50 amp twistlock …)
2” high white-on-black circuit labels standard
one side (other labeling available: 2 side
polycarbonate labels, 1 and 2 side engraved
lamicoid labels, or 1 side engraved covers)
DIN rail mounted screwless “tension clamp”
wire terminals 20 amp circuits,
maximum wire size: 8 gauge
Screw terminals for 50 and 100 amp circuits.
Maximum wire size for 50 amp: 1 gauge.
Maximum wire size for 100 amp: 2/0
Wide variety of mounting and hanger brackets
available — (see Brackets)
New packaging protects strips and aids
in installation
99L-(QCM/X)(QCM/X) -T- H
For additional connector types the form is the same as above except we group all
connector types in parentheses to avoid confusion. You can add as many
connector types as you need.
Example: 9950-(20CP/20)(4AO/1)-L-22. This strip has twenty Twistlock™ pigtails
wired on twenty circuits (one to one) and four Edison outlets wired on one circuit
for work lights, terms left and type 22 hangers.
Connectors other than 20 Amp
99L-(QCM/X)(QCM@50/X) -T- H
For all but 20 amp connectors you must specify the amperage they are rated for.
The form is the same except you add the current rating like this: @ Amps.
Example: 9950-(20BP/20)(4BO@50/4)-L-22. This strip has twenty stage pin pigtails
wired on twenty circuits and four stage pin outlets at 50 Amps wired on four
circuits, terms left and type 22 hangers.
Non-standard connector types
99L-(QCM/X) (Q*Mfg. Model #/X) (QCM/X) -T- H
Non-standard connector types must be UL listed to maintain the UL listing of the
connector strip. Their model numbering is similar with two exceptions.
1) Use the manufacturers model or part number separated by an asterisk (hyphens
separate electrical from mechanical information)
2) Mounting information is unnecessary because it is included in part number.
Example: 9950-(20BP/20)(8*HBL2410/4)(4AO/1) -L-22. This strip has twenty
stage pin pigtails wired on twenty circuits, eight HBL2410’s wired on 4 circuits for
moving lights and four Edison outlets wired on one circuit for work lights, terms
left and type 22 hangers.
DMX in Connector Strips
99L-(QCM/X) (Q*Mfg. Model #/X) (QCM/X) (8D/2) -T- H
DMX model numbering (DMX rules and details on back page):
1) Show number of DMX panels on number of universes
(maximum of two universes, or call factory)
2) Mounting information is unnecessary because it is a panel mount assembly.
Example: 9950-(20BP/20)(8*HBL2410/4)(4AO/1)(8D/2) -L-22. This is the same
connector strip as above with the addition of the DMX pass through panels to
control the moving lights.
M U LT I C O N D U C T O R C A B L E A N D A C C E S S O R I E S
9700 Model
Gridiron junction box
Rigging
(by others)
DMX Gridiron
Junction Box
Cable cradle
(See table below)
Kellems grip™
Strain Relief
(See table below)
9900 Series
Connector Strip
DMX input cable
DMX input box
Kellems grip™
Strain Relief
Kellems
Support
Grip™
Panel-Mount
Outlet
"Pigtail"
Connector
ETC recommends using an additional
strain relief for attaching multicable
to fixture pipe (Pipe by others)
* Hanger brackets should be mounted every five feet.
Cable and Accessory Specifications with ETC Part #'s
Cable
Part #
OD
12/3
12/9
12/14
12/20
12/26
12/30
12/37
10/3
10/4
10/5
10/10
10/16#
10/20#
6/3
6/5
W707
W721
W718
W713
W715
W716
W717
W512
W516
W517
W513
W514
W515
W814
W815
.610
.915
1.105
1.315
1.453
1.535
1.653
.671
0.73
0.83
1.12
1.305
1.44
0.885
1.09
LB/FT
.24
.60
.85
1.10
1.45
1.54
1.65
.31
0.371
0.496
0.98
1.19
1.45
0.76
1.14
Kellems®
Strain Relief
Grips
Kellems®
Deluxe Cord
Grips
Kellems® Standard
Support (pickup)
Double eye
Cable
Cradle
HW633
HW634
HW635
HW636
HW636
HW636
HW637
HW633
HW633
HW634
HW635
HW636
HW636
HW634
HW635
HW6186
HW6188
HW6189
HW6191
HW6192
HW6192
HW6193
HW6187
HW6187
HW6187
HW6189
HW6191
HW6192
HW6188
HW6189
Hw6206
HW6208
HW6209
HW6210
HW6210
HW6211
HW6211
HW6207
HW6207
HW6208
HW6209
HW6210
HW6210
HW6208
HW6209
N/A
PSE8804
PSE8804
PSE8804
PSE8804
PSE8804
PSE8804
PSE8804
PSE8804
PSE8804
PSE8804
PSE8804
PSE8804
PSE8804
PSE8804
# Requires minimum order and extended lead time, call for details.
Strain Relief Grips and Deluxe Cord Grips are not intended to support loads.
See Hubbell technical section for Support Grip ratings and safety factors.
DMX "Pass-Thru"
Panel
Mounting
Hanger Brackets
Fixture Pipe
(by others)
Connector Strips
Distribution Series
Types 11 through 18 are Mounting Brackets and are intended to support
the connector strip only and not intended to support a pipe. No mounting
hardware is supplied with type 11, 12, and 13 because it is the installers
responsibility to determine the appropriate mounting hardware.
Type 11
16.00"
21.5"
14.70"
Type
Usage and Notes
11
Mounts strips with the 6.25" dimension parallel to and directly on a
wall or ceiling. No mounting hardware is supplied.
Mounts strips with the 3.3" dimension parallel to and directly on a
wall or ceiling. No mounting hardware is supplied.
Mounts strips in a corner. No mounting hardware is supplied.
Mounts strips to a pipe with the 6.25" dimension parallel to the floor
over a grid. Bracket is attached to the pipe with a U-bolt. Stiffeners
should be bolted between connector strips (not provided).
Same as 14 w/vertical segment of hanger bolted together to allow
mounting at any angle over pipe
Similar to 14 but mounts strips to pipes with the 6.25" dimension
perpendicular to the floor. The u-bolt can be mounted from either
side making this hanger useful for any application where a connector
strip is mounted to a pipe
Same as 16, but the vertical segment of the hanger is bolted together
to allow the connector strip to be mounted at any angle to the pipe
Use where a connector strip is mounted directly on a pipe at 90 degrees
12
13
14
Type 21
Type 12
Type 26
15
16
Type 13
17
(2)
28.00"
18
9.25"
(2)
25.00"
Types 21 through 26 are Hanger Brackets and support both the connector strip
and 1.5" schedule 40 pipe (1.9" O.D.)
22.16"
21.25"
Type 14 †
Type
Usage and Notes
21
The default hanger, this unit hangs the connector strip and a pipe
to a fly system. The .75" hole in the top of the bracket is for shackles
or thimbles.
Designed to hang the connector strip and a pipe from a system pipe
already installed.
Similar to 22, but designed to support the connector strip and the
term box at the end of the pipe (This unit is automatically substituted
for one 22 when a strip has a term box; do not order)
Hangs the connector strip and a pipe from a system pipe (already
installed in a fly system) to under hang fixtures from both pipes. The
.75" hole in the top of the bracket for shackles or thimbles can be
used to hang both pipes.
Similar to 24, but designed to support the connector strip and the
term box at the end of the pipe (This unit is automatically substituted
for one 24 when a strip has a term box; do not order)
Similar to 23 but 7" shorter. Use where space is a concern. Cannot be
used on connector strips with term boxes. The .75" hole in the top of
the bracket is for thimbles and wire rope.
22
9.25"
Type 22
23
Type 32
(2) Type 23
(2) Type 33
Type 15 †
24
25
12.25"
23.00"
26
Type 16 †
Types 31 through 34 are "flat" Hanger Brackets that support both the
connector strip and 1.5" schedule 40 pipe (1.9" O.D.)
(Note: These do not center hang loads).
12.25"
Type 34**
48.00"
Type 17 †
(2)
42.16"
Type
Usage and Notes
31
32
33
34
Straight version of the 21 hanger. Pipe attached with U-bolts.
Straight version of the 22 hanger. Pipe attached with U-bolts.
Straight version of the 23 hanger. Pipe attached with U-bolts.
Unit is designed to mount a connector strip on catwalk railings.
Place u-bolts from 11.8" to 16.6 inches center to center using four
positions on the top and slots on the bottom of bracket to cover a
range of spacing.
18.00"
(2)
14.5"
13.25"
Type 18
† Designed for use with Unistrut stiffener for grid applications—these hangers
not intended to support pipe.
Type 24
(2) Type 25
Type 31
(2) Type 35
Note: Clamps and U-bolts on mounting brackets are designed to be used with
1.5" I.D. Schedule 40 steel pipe. (1.9" nominal O.D.)
Type 23, 25, & 33 are automatically supplied for connector strips
w/terminal boxes
Connector Strips
Distribution Series
DMX CONNECTOR STRIPS
DMX Pass
Thru Panel
Side View
PUSH
Top View
Pass
Thru
DMX
Output
To device
DMX
Input
From device
Switch Guard Detail
Pass Thru "engaged" when green
DMX data originates from an optically
isolated DMX 512 source (opto-splitter)
Last device on this segment should be
terminated with termination switch on
that device
Using both jacks and terminating at the
same time may yield unpredicable results.
DMX Pass Thru
• Wire from the DMX output
to DMX controlled device
(moving light or scroller)
with a 5 pin DMX cable.
• Wire from DMX out on device
to pass thru panel so DMX is
routed to next location on strip
• Engage the Pass Thru switch
(center will turn green) to route
DMX past unused locations.
• The last device on a
connector strip should
be terminated with the
termination switch on
the device.
• DMX should originate from an
optically isolated source for each
connector strip.
• This system maintains a linear
DMX segment eliminating common
DMX wiring problems.
Fixture
Fixture
PHYSICAL
Connector Types
Cross Section
DMX barrier as required.
Connector
Connector
Connector
type B
type A 20A parallelblade U-Ground
type C
20, 50 or
20A grounded
100A pin
twist-lock®
connector
Nema L5•20R
(20 Amp
Shown)
(A.K.A. Edison)
Nema 5•20R
(Hubbell®)
(Hubbell®)
6.25"/15.9cm
3.3"
8.4cm
Americas 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979, USA
Europe Unit 5, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK
■
■
Tel +1 608 831 4116 ■ Fax +1 608 836 1736 ■ Toll free 800 688 4116 ■ Toll free fax 800 555 8912
Tel +44 (0)20 8896 1000 ■ Fax +44 (0)20 8896 2000
Asia Room 605-606, Tower III Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong
Web www.etcconnect.com
■
Email (US) mail@etcconnect.com
■
(UK) mail@etceurope.com
■
■
Tel +852 2799 1220
(Asia) mail@etcasia.com
Copyright © 2004 ETC. All Rights Reserved. All product information and specifications subject to change. 7099L1002 Rev. C Printed in USA 12/04
■
Fax +852 2799 9325
ETC®
Fresnel Series
Y
R
A
N
I
IM
L
E
PR
G E N E R A L I N F O R M AT I O N
S P E C I F I C AT I O N S
ETC combines the efficiency of the HPL lamp with the singular
optical qualities of the fresnel optical system to create the truly
advanced ETC Source Four Fresnel. Traditional fresnel optics provide
a unique quality of blending wash light and beam shaping via barn
doors for well-defined, soft-edged area lighting. The Source Four
Fresnel combines this classic system with a unique reflector design
enabling the HPL 750W-equipped Source Four Fresnel to equal the
lumen output of other 1000W fresnel fixtures. Spot-to-flood focus
is accomplished by large, easy-to-use knob for quick adjustments
in inconvenient positions. The unique Quick Xchange socket design
permits re-lamping from underneath the fixture without breaking
focus in most situations.
LAMP
• HPL – compact tungsten filament contained in a krypton/
xenon-filled quartz glass envelope (see table for suitable
lamp types)
• Uses same lamp as all Source Four fixtures for
common inventory
• 750W maximum
• Patented filament geometry makes for extremely efficient
light collection and transmission
• Integral die-cast aluminum heat sink lamp base
S P E C I F I C AT I O N S
Source Four Fresnel
O R D E R I N G I N F O R M AT I O N
PHYSICAL
• Rugged die-cast aluminum construction
• Convenient full-size zoom adjustment knob
• Unique HPL quick exchange socket enables easy
lamp changes
• Sliding yoke mount for variable balance point
• Fully enclosed accessory slots for no light leak
• UL and cUL listed
ELECTRICAL
• 100V-240V, 50/60Hz
• High temperature three-conductor 36” leads in a glass fiber
outer sleeve
• Supports ETC Dimmer Doubling™ technology
OPTICAL
• 7”/175mm aperture
• 20° - 65° field angle zoom range
• True fresnel optical system for good barn-door beam
shaping performance
• Glass reflector with dichroic coating optimized for
HPL performatnace
MODEL
DESCRIPTION
FRES7
7” Source Four Fresnel (Black)
FRES7-1
7” Source Four Fresnel (White)
Connector Designation
Use suffixes below to specify factory–fitted connector type
MODEL
DESCRIPTION
A
Parallel-blade U-ground connector (Edison)
B
Two-pin and ground, 20A connector
C
Grounded 20A twist lock connector
M
Dimmer Doubling Connector (NEMA L515P)
See back page for Source Four Fresnel accessories
1 of 6
ETC®
Fresnel Series
PHOTOMETRICS
Photometric data below is measured with an HPL 750W/115V 300 hr lamp. To convert data when using any other HPL lamp, use the lumen or
candela multiplying factors (Lm MF or Cd MF) for that specific lamp. These multiplying factors are listed in the Lamps table in this datasheet. For
lumen data, multiply by the Lm MF. For candela or footcandle data, multiply by the Cd MF.
Source Four Fresnel - Flood Focus (115V)
Degree
Candela
Field
Lumens
65°
17,600
10,690
Iso-Illuminance Diagram
Beam
Lumens
Lumens per
Watt
7,590
14.3
(Flat Surface Distribution)
Y
10%
For field diameter at any distance, multiply distance by 1.262
For beam diameter at any distance, multiply distance by .978
65˚
Field Angle
52˚
Beam Angle
X
50%
.059 .118 .176 .235
15.0’
4.6m
20.0’
6.1m
25.0’
7.6m
Field Diameter
12.6’
3.8m
18.9’
5.8m
25.2’
7.7m
31.5’
9.6m
Illuminance (fc)
176
78
44
28
1,894
842
474
303
Illuminance (lux)
Candela Plot
Candela
Throw Distance (d)
10.0’
3.0m
18000
16000
14000
12000
10000
8000
6000
4000
2000
0
-35 -30 -25 -20 -15 -10 -5
X
Y
0
5
10 15 20 25 30 35
Degrees
Source Four Fresnel - Medium Focus (115V)
Iso-Illuminance Diagram
Degree
Candela
Field
Lumens
Beam
Lumens
Lumens per
Watt
40°
51,500
7,390
3,580
9.9
(Flat Surface Distribution)
Y
10%
For field diameter at any distance, multiply distance by 0.716
For beam diameter at any distance, multiply distance by 0.367
40˚
Field Angle
21˚
Beam Angle
X
50%
.059 .118 .176 .235
15.0’
4.6m
20.0’
6.1m
25.0’
7.6m
Field Diameter
7.2’
2.2m
10.7’
3.3m
14.3’
4.4m
17.9’
5.5m
Illuminance (fc)
515
229
129
82
5,543
2,464
1,386
887
Illuminance (lux)
Candela Plot
60000
50000
Candela
10.0’
3.0m
Throw Distance (d)
40000
X
30000
Y
20000
10000
0
-25
-20
-15
-10
-5
0
Degrees
2 of 6
5
10
15
20
25
ETC®
Fresnel Series
PHOTOMETRICS
Source Four Fresnel - Narrow Focus (115V)
Iso-Illuminance Diagram
Degree
Candela
Field
Lumens
Beam
Lumens
Lumens per
Watt
20°
124,300
3,.990
1,930
5.3
(Flat Surface Distribution)
Y
10%
For field diameter at any distance, multiply distance by 0.42
20˚
X
Field Angle
9˚
Beam Angle
For beam diameter at any distance, multiply distance by 0.21
50%
.059 .118 .176 .235
15.0’
4.6m
20.0’
6.1m
25.0
7.6m
Field Diameter
3.5’
1.1m
5.2’
1.6m
6.9’
2.1m
8.6’
2.6m
Illuminance (fc)
1,243
552
311
199
Illuminance (lux)
13,380
5,946
3,345
2,141
Candela Plot
140000
120000
Candela
Throw Distance (d)
10.0’
3.0m
100000
80000
X
Y
60000
40000
20000
0
-15
-10
-5
0
Degrees
3 of 6
5
10
15
ETC®
Fresnel Series
LAMPS
To determine Candela (Cd) or Lumens (Lm) for any other HPL lamp, multiply the Candela or Lumen value by the appropriate multiplying factor
(CdMF or LmMF) shown for that lamp in the table below.
ETC
Avg.
Rated Life
Spot
Spot
Flood
Flood
Cd MF
Lm MF
Cd MF
Lm MF
3,250
300
1.00
1.00
1.00
1.00
3,050
1,500
Watts
Volts
Initial
Lumens
Color
Temp. K
HPL 750/115**
750
115
21,900
HPL 750/115X
750
115
16,400
RT113
HPL 575/115**
575
115
16,520
3,250
300
RT114
HPL 575/115X
575
115
12,360
3,050
2,000
RT142
HPL 375/115
375
115
10,540
3,250
300
RT143
HPL 375/115X
375
115
8,500
3,050
1,000
N/A
HPL 750/120
750
120
21,900
3,250
300
N/A
HPL 750/120X
750
120
16,400
3,050
1,500
RT115
HPL 575/120
575
120
16,520
3,250
300
RT171
HPL 575/120X
575
120
12,360
3,050
2,000
RT112
HPL 550/77*
550
77
16,170
3,250
300
RT117
HPL 550/77X*
550
77
12,160
3,050
2,000
RT160
HPL 750/230**
750
230
19,750
3,200
300
N/A
HPL 750/230X
750
230
15,600
3,050
1,500
Part #
Lamp Code
RT116
RT196
RT129
HPL 575/230**
575
230
14,900
3,200
400
RT138
HPL 575/230X
575
230
11,780
3,050
1,500
RT154
HPL 375/230X
375
230
7,800
3,050
1,000
N/A
HPL 750/240
750
240
19,750
3,200
300
N/A
1,500
HPL 750/240X
750
240
15,600
3,050
RT130
HPL 575/240
575
240
14,900
3,200
400
RT139
HPL 575/240X
575
240
11,780
3,050
1,500
RT155
HPL 375/240X
375
240
7,800
3,050
1,000
N
O
O
S
G
IN
M
O
C
.78
.86
.81
.84
N
O
O
S
G
IN
M
O
C
Source Four Fresnels rated for 750W maximum.
*77 Volt HPL lamps are for use with ETC Dimmer Doubling™ technlology only.
**Photometric data was prepared using a production fixture and the Prometric CCD measurement system. Fixture adjusted for cosine distribution and tested with calibrated
lamp at rated voltage. All data normalized to nominal lamp lumens in accordance with IES LM-73-04. Testing performed at ETC West, Hollywood, CA. All other multiplying
factors extrapolated from primary test data.
For links to photometry file downloads (IES LM-63-02 format) go to www.etcconnect.com.
HPL Specified Tolerances: Watts +/- 5%, Lumens +/-7%, Average life +/-10%, Color Temperature +/- 50K
“N/A” lamps are not available for purchase from ETC. Contact your dealer for purchase.
4 of 6
ETC®
Fresnel Series
O R D E R I N G I N F O R M AT I O N
PHYSICAL
Continued from front page...
Source Four Fresnel Accessories
19.6”
497mm
15.0”
381mm
12.8”
325.6mm
6.9”
176mm
MODEL
DESCRIPTION
407CF
Color frame (7.5”) (included)
400SC
Safety Cable
400CC
C-Clamp
400BD
Barn Door
400PTH3
Top hat, 3”
400PTH6
Top hat, 6”
400PHH
Half hat
400PGE3
Gel extender, 3”
400PGE6
Gel extender, 6”
400WB
Weighted base
400XBTH
Cross baffle top hat
400L
Egg crate louver
Note: For colors other than black and white, please call ETC.
6.5”
165mm
8.6”
218.9mm
9.43”
239.5mm
Source Four products are protected by one or more of the
following patents:
10.9”
278.4mm
U.S.
USRE36,3316, US5,345,371, US6,092,914
and US5,775,799
U.K.
GB0592589, GB0673488, 99930527.9*
Germany
DE0592589, GB0673488, 99930527.9*
Japan
JP2,501,772
* European patent application number
9.1”
13.5”
341.6mm
5.64” 229.9mm
143.3mm
7.32”
186mm
12.4”
315mm
Source Four Fresnel Weights*
MODEL
Fresnel
WEIGHT
SHIPPING WEIGHT
lbs
kgs
lbs
kgs
13.3
6.1
17.5
8.0
*Add 2.3 lbs for C-clamp
5 of 6
ETC®
Fresnel Series
Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736
London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000
Rome, IT • Via Pieve Torina, 48, 00156 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0)20 8752 8486
Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00
Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325
Web • www.etcconnect.com • Copyright©2011 ETC. All Rights Reserved. All product information and specifications subject to change. 7064L1001 Rev. A Printed in USA 3/11 6 of 6
ETC®
Source Four® jr 26°
Ellipsoidal Series
S p e c i f i c at i o n s
S p e c i f i c at i o n s
PHYSICAL
• Rugged die cast aluminum construction
• 20 gauge stainless steel shutters in a bi-plane assembly
• Interchangeable lens tubes with smooth–running teflon
guides provide three user-fit field angle options
• High impact, thermally insulated knobs and shutter handles
• Two accessory slots, and a top mounted, gel frame retainer
• Steel yoke with two mounting positions
• Positive locking, hand-operated yoke clutch
• Slot for stainless steel patterns
• Slot with sliding cover for motorized pattern devices or
optional iris
• UL and cUL Listed
ELECTRICAL
• 115-240V, 50/60Hz
• High temperature 3–conductor 36” leads in a glass fiber
outer sleeve
• Supports ETC Dimmer Doubling™ technology
LAMP
• HPL — compact tungsten filament contained in a kryptonfilled quartz envelope (see table for suitable lamp types)
• 575W Maximum
• Integral die cast aluminum heat sink lamp base
OPTICAL
• Optimized optical system for efficient
photometric performance
• Projector-quality, high contrast aspheric lens
• Faceted borosilicate reflector with dichroic cold mirror coating
removes greater than 90% infrared radiation (heat) and
reflects greater than 95% of visible light
• Reflector secured with anti-vibration shock mounts
• Tool free, positive locking X, Y and Z lamp centering
adjustments, unaffected by relamping
• Beam edge continually adjustable hard-to-soft
• Interchangeable lens assembly kits permit selection of 26°,
36°, and 50° field angles, and 25°-50° zoom range
Ord e r i n g i n f o rm a t i o n
Source Four jr
Model
Description
426J
26˚ Source Four jr ellipsoidal (black)
426J-1
26˚ Source Four jr ellipsoidal (white)
ETC Source Four jrs are supplied with C-clamp, color frame and 3’ (96cm) leads as
standard
Connector Designation
Use Suffixes below to specify Factory–Fitted Connector type
Model
Description
A
Parallel-blade U-ground connector
B
Two-pin and ground, 20 amp connector
C
Grounded, 20 amp, twistlock connector
M
Dimmer Doubling Connector (NEMA L515P)
See back page for Source Four jr Accessories
1 of 4
ETC®
Source Four® jr 26°
Ellipsoidal Series
photometrics
25˚
Field Angle
20˚
Beam Angle
Photometric data below is measured with an HPL 575W/115V 300 hr lamp. To convert data when using any other HPL lamp, use the lumen or
candela multiplying factors (Lm MF or Cd MF) for that specific lamp. These multiplying factors are listed in the Lamps table in this datasheet. For
lumen data, multiply by the Lm MF. For candela or footcandle data, multiply by the Cd MF.
Source Four jr 26˚(cosine)
Throw Distance (d)
20’
6.1m
30’
9.1m
35’
10.7m
45’
13.7m
Field Diameter
8.9’
2.7m
13.3’
4.1m
15.5’
4.7m
20’
6.1m
Degree
Candela
Field
Lumens
Beam
Lumens
Efficiency
Lumens
per
watt
Illuminance (fc)
229
102
75
45
26˚
91,480
7,795
5,913
47.2%
13.6
2,462
1,094
804
486
Illuminance (lux)
Metric Conversions: For Meters multiply feet by .3048
For Lux multiply footcandles by 10.76
For illumination with any lamp, multiply the candlepower of a beam spread by the
multiplying factor (mf) shown for that lamp.
To determine illumination in footcandles or lux at any throw distance, divide
candlepower by distance squared.
For Field diameter at any distance, multiply distance by 0.44
For Beam diameter at any distance, multiply distance by 0.35
Iso-Illuminance Diagram
Cosine Candela Plot
Y
120000
10%
100000
Candela
80000
X
X
60000
Y
40000
20000
50%
0
-15
-12
-9
-6
-3
0
Degrees
Complete IES photometry data files (LM-63-02 format) may be downloaded from the ETC website.
Go to http://www.etcconnect.com/downloads.asp
2 of 4
3
6
9
12
15
ETC®
Source Four® jr 26°
Ellipsoidal Series
Lamps
To determine Candela (Cd) or Lumens (Lm) for any other HPL lamp, multiply the Candela or Lumen value by the appropriate multiplying factor
(CdMF or LmMF) shown for that lamp in the table below.
ETC Part # Lamp Code
Watts
Volts
Initial
Lumens
Color
Temp. K
Average
Rated Life
26°
26°
Cd MF
Lm MF
1.00
1.00
RT113
HPL 575/115**
575
115
16,520
3,250
300
RT114
HPL 575/115X
575
115
12,360
3,050
2,000
.64
.71
RT142
HPL 375/115
375
115
10,540
3,250
300
.84
.64
RT143
HPL 375/115X
375
115
8,500
3,050
1,000
.58
.48
RT115
HPL 575/120
575
120
16,520
3,250
300
1.00
1.00
RT171
HPL 575/120X
575
120
12,360
3,050
2,000
.64
.71
RT112
HPL 550/77*
550
77
16,170
3,250
300
1.02
.98
RT117
HPL 550/77X*
550
77
12,160
3,050
2,000
.66
.73
RT129
HPL 575/230**
575
230
14,900
3,200
400
.68
.63
RT138
HPL 575/230X
575
230
11,780
3,050
1,500
.44
.45
RT154
HPL 375/230X
375
230
7,800
3,050
1,000
.38
.33
RT130
HPL 575/240
575
240
14,900
3,200
400
.65
.63
RT139
HPL 575/240X
575
240
11,780
3,050
1,500
.41
.44
RT155
HPL 375/240X
375
240
7,800
3,050
1,000
.38
.33
Source Four jr is rated for 575W maximum.
*77 Volt HPL lamps are for use with ETC Dimmer Doubling technlology only.
**Photometric data was prepared using a production fixture and the Prometric CCD measurement system. Fixture adjusted for cosine distribution and tested with calibrated
lamp at rated voltage. All data normalized to nominal lamp lumens in accordance with IES LM-73-04. Testing performed at ETC West, Hollywood, CA. All other multiplying
factors extrapolated from primary test data.
For links to photometry file downloads (IES LM-63-02 format) go to www.etcconnect.com.
HPL Specified Tolerances: Watts +/- 5%, Lumens +/-7%, Average life +/-10%, Color Temperature +/- 50K
3 of 4
ETC®
Source Four® jr 26°
Ellipsoidal Series
p hys i c a l
Ord e r i n g i n f o rm a t i o n
Continued from front page...
Source Four jr Accessories
13.7”/ 348mm max
10.6”/ 269mm min
8.8”/ 224mm max
6.1”/155 mm min
6.9”
175mm
19.3”
490mm
Model
Description
450JL
50˚ jr lens assembly
436JL
36˚ jr lens assembly
426JL
26˚ jr lens assembly
400JZK
Source Four jr Zoom upgrade kit*
400CC
C–clamp (included)
400SC
Safety cable
400JRS
Drop-in iris
400CF
Colorframe (6.25”) (included)
400DN
Donut (6.25”)
400TH
Top hat
400HH
Half hat
400GE
Gel extender
400PH-M
Pattern Holder (M size)
Note: For colors other than black and white, please call ETC.
* Converts any Source Four jr to a Source Four jr Zoom
18.5”
470mm
Source Four products are protected by one or more of the following
patents:
U.S.
7.0”
178mm
9.7”
246mm
USRE36,3316, US5,345,371, US6,092,914 and
US5,775,799
U.K.
GB0592589, GB0673488, 99930527.9*
Germany
DE0592589, GB0673488, 99930527.9*
Japan
JP2,501,772
* European patent application number
Source Four jr Weights*
model
426j
weight
shipping weight
lbs
kgs
lbs
kgs
10
4.5
16.5
7.5
*Includes 2.3 lbs for C-clamp
Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736
London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000
Rome, IT • Via Pieve Torina, 48, 00156 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0)20 8752 8486
Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00
Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325
Web • www.etcconnect.com • Copyright©2010 ETC. All Rights Reserved. All product information and specifications subject to change. 7062L1007 Rev. F Printed in USA 12/10
4 of 4
ETC®
Source Four® 26˚
Ellipsoidal Series
S P E C I F I C AT I O N s
S P E C I F I C AT I O N s
physical
• Rugged, die cast aluminum construction
• Rotating shutter assembly ±25˚
• 20 gauge stainless steel shutters in a tri-plane assembly
• Interchangeable lens tubes with smooth-running teflon
guides provide nine user-fit field angle options
• Thermally insulated rear handle
• High impact, thermally insulated knobs and shutter handles
• Two accessory slots and a top mounted, gel frame retainer
• Steel yoke with two mounting positions
• Positive locking single-clutch fixture body
• Slot for glass or stainless steel patterns
• Wide accessory slot with sliding cover for motorized pattern
devices or optional iris
• UL and cUL Listed
ELECTRICAL
• 115-240V, 50/60Hz
• High temperature 3-conductor 36” leads in a glass fiber outer sleeve
• Supports ETC Dimmer Doubling™ technology
LAMP
• 750W maximum
• HPL – compact tungsten filament contained in a kryptonfilled quartz envelope (see table for available lamp options)
• Patented filament geometry makes for extremely efficient
light collection and transmission
• Integral die cast aluminum heat sink lamp base
OPTICAL
• Re-optimized optical system for improved photometric
performance and field uniformity
• Projector-quality, high contrast aspheric lens
• Optional enhanced definition lens tube available for even
higher image quality
• Faceted borosilicate reflector with dichroic cold mirror coating
removes greater than 90% infrared radiation (heat) and
reflects greater than 95% of visible light
• Reflector secured with anti-vibration shock mounts
• Lens(es) secured with anti-vibration shock mounts
• Tool free, positive locking X, Y and Z lamp centering
adjustments, unaffected by relamping
• Beam edge continually adjustable hard-to-soft
• Interchangeable lens barrels permit selection of 5˚, 10˚, 14°,
19˚, 26˚, 36˚, 50˚, 70°, and 90° field angles as well as 19˚, 26˚,
36˚, and 50˚ EDLT lenses
O rderin g infor m ation
Source Four
Model
Description
426
26˚ ellipsoidal (black)
426-1
26˚ ellipsoidal (white)
ETC Source Four are supplied with C-clamp, color frame and 3’ (96cm) leads as
standard
Connector Designation
Use Suffixes below to specify Factory–Fitted Connector type
Model
Description
-A
Parallel-blade U-ground connector
-B
Two-pin and ground, 20 amp connector
-C
Grounded, 20 amp, twistlock connector
-M
Dimmer Doubling Connector (NEMA L515P)
See back page for Source Four Accessories
1 of 4
ETC®
Source Four® 26˚
Ellipsoidal Series
photo m etrics
25˚
Field Angle
18˚
Beam Angle
Photometric data below is measured with an HPL 750W/115V 300 hr lamp. To convert data when using any other HPL lamp, use the lumen or
candela multiplying factors (Lm MF or Cd MF) for that specific lamp, listed in the Lamps table in this datasheet. For lumen data, multiply by the
Lm MF. For candela or footcandle data, multiply by the Cd MF.
Throw Distance (d)
15’
4.6m
30’
9.1m
45’
13.7m
60’
18.1m
Field Diameter
6.7’
2.0m
13.4’
4.1m
20.1’
6.1m
26.8’
8.2m
Illuminance (fc)
783
196
87
49
8,432
2,108
937
527
Illuminance (lux)
Source Four 26˚(cosine)
Degree
Candela
Field
Lumens
Beam
Lumens
Efficiency
Lumens
per watt
26˚
176,255
13,690
9,040
62.5%
18.3
Metric Conversions: For meters, multiply feet by .3048
For Lux multiply footcandles by 10.76
To determine center beam illumination in footcandles at any throw
distance, divide candela by the throw distance squared.
For Field diameter at any throw distance, multiply the throw distance
by .45
For Beam diameter at any throw distance, multiply the throw
distance by .32
Iso-Illuminance Diagram
(Flat Surface Distribution)
Cosine Candela Plot
Y
200000
10%
180000
50%
X
140000
Candela
% illuminance
foot candle or lux
160000
120000
X
Y
100000
80000
60000
40000
20000
0
-15
-12
-9
-6
-3
0
Degrees
Degrees
Complete IES photometry data files (LM-63-02 format) may be downloaded from the ETC website.
Go to http://www.etcconnect.com/downloads.asp
2 of 4
3
6
9
12
15
ETC®
Source Four® 26˚
Ellipsoidal Series
L a m ps
To determine Candela (Cd) or Lumens (Lm) for any other HPL lamp, multiply the Candela or Lumen value by the appropriate multiplying factor
(CdMF or LmMF) shown for that lamp in the table below.
Color
Temp. K
Average
Rated Life
26°
26°
ETC Part #
Lamp Code
Watts
Volts
Initial
Lumens
Cd MF
Lm MF
RT116
HPL 750/115**
750
115
21,900
3,250
300
1.00
1.00
RT196
HPL 750/115X
750
115
16,400
3,050
1,500
.64
.74
RT113
HPL 575/115**
575
115
16,520
3,250
300
.78
.82
RT114
HPL 575/115X
575
115
12,360
3,050
2,000
.56
.56
RT142
HPL 375/115
375
115
10,540
3,250
300
.66
.52
RT143
HPL 375/115X
375
115
8,500
3,050
1,000
.45
.40
N/A
HPL 750/120
750
120
21,900
3,250
300
1.00
1.00
N/A
HPL 750/120X
750
120
16,400
3,050
1,500
.64
.74
RT115
HPL 575/120
575
120
16,520
3,250
300
.78
.82
RT171
HPL 575/120X
575
120
12,360
3,050
2,000
.56
.56
RT112
HPL 550/77*
550
77
16,170
3,250
300
.77
.77
RT117
HPL 550/77X*
550
77
12,160
3,050
2,000
.59
.56
RT160
HPL 750/230**
750
230
19,750
3,200
300
.64
.75
N/A
HPL 750/230X
750
230
15,600
3,050
1,500
.40
.59
RT129
HPL 575/230**
575
230
14,900
3,200
400
.53
.61
RT138
HPL 575/230X
575
230
11,780
3,050
1,500
.38
.45
RT154
HPL 375/230X
375
230
7,800
3,050
1,000
.29
.32
N/A
HPL 750/240
750
240
19,750
3,200
300
.64
.75
N/A
HPL 750/240X
750
240
15,600
3,050
1,500
.40
.59
RT130
HPL 575/240
575
240
14,900
3,200
400
.50
.61
RT139
HPL 575/240X
575
240
11,780
3,050
1,500
.36
.45
RT155
HPL 375/240X
375
240
7,800
3,050
1,000
.29
.32
Source Four is rated for 750W maximum
*77 Volt HPL lamps are for use with ETC Dimmer Doubling technology only
**Photometric data was prepared using a production fixture and the Prometric CCD measurement system. Fixture adjusted for cosine distribution and tested with calibrated
lamp at rated voltage. All data normalized to nominal lamp lumens in accordance with IES LM-73-04. Testing performed at ETC West, Hollywood, CA. All other multiplying
factors extrapolated from primary test data.
For links to photometry file downloads (IES LM-63-02 format) go to www.etcconnect.com
HPL Specified Tolerances: Watts +/- 5%, Lumens +/-7%, Average life +/-10%, Color Temperature +/- 50K
“N/A” lamps are not available for purchase from ETC. Contact your Dealer for purchase.
3 of 4
ETC®
Source Four® 26˚
Ellipsoidal Series
physical
O rderin g infor m ation
Continued from front page...
ETC
Source Four Accessories
14.9”/ 378mm max.
11.8”/ 300mm min.
10.0”/ 254mm max.
7.3”/ 185mm min.
8.5”
216mm
20.1”
511mm
22.8”
579mm
21.3”
541mm
Model
Description
426LT
26˚ lens tube complete (black)
426LT-1
26˚ lens tube complete (white)
426EDLT
26° Enhanced Definition Lens Tube complete
(black)
426EDLT-1
26° Enhanced Definition Lens Tube complete
(white)
400CC
C–clamp (included)
400PH-A
Pattern holder (A size)
400PH-B
Pattern holder (B size)
400PH-G
Glass pattern holder
400SC
Safety cable
400RS
Drop-in iris
400CF
Colorframe (6.25”) (included)
400DN
Donut (6.25”)
400TH
Top hat
400HH
Half hat
400GE
Gel extender (Recommended for 19° and 26°
only)
407GE
Conical gel extender (requires 407CF below)
407CF
7.5” Square color frame (required for 14°, 70°,
90° and 407GE)
400FB
Source Four fixture body, single clutch
Note: For colors other than black or white, please call ETC.
6.8”
173mm
13.3”
338mm
Source Four Weights*
model
weight
26˚
Source Four products are protected by one or more of the following
patents:
shipping weight
lbs
kgs
lbs
kgs
14
6.4
20
9.1
*Includes 2.3 lbs for C-clamp
U.S.
USRE36,3316, US5,345,371, US6,092,914 and
US5,775,799
U.K.
GB0592589, GB0673488, 99930527.9*
Germany
DE0592589, GB0673488, 99930527.9*
Japan
JP2,501,772
* European patent application number
Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736
London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000
Rome, IT • Via Pieve Torina, 48, 00156 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0)20 8752 8486
Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00
Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325
Web • www.etcconnect.com • Copyright©2010 ETC. All Rights Reserved. All product information and specifications subject to change. 7060L1008 Rev. G Printed in USA 12/10 4 of 4
ETC®
Sensor®+ Racks
Sensor+ Series
O r d e r i n g i n f o r m at i o n
Installation Racks
Model
Description
SR48+
Sensor+ 48 Module Rack
SR24+
Sensor+ 24 Module Rack
SR12+
Sensor+ 12 Module Rack
SR6+
Sensor+ 6 Module Rack
SR24+1P
Sensor+ 24 Module Single Phase Rack
SR12+1P
Sensor+ 12 Module Single Phase Rack
SR6+1P
Sensor+ 6 Module Single Phase Rack
Rack Options*
Model
Description
AT48
Amp-Trap fuse option for 48-module rack
AT24
Amp-Trap fuse option for 24-module rack
AT12
Amp-Trap fuse option for 12-module rack
G e n e r a l I n f o r m at i o n
BK48
Bussing kit for 2 – 48-module racks
Sensor+ dimming systems provide high density, professional features
and exceptional reliability for lighting applications that require the
best the entertainment industry can offer.
BK24
Bussing kit for 2 – 24-module racks
BK12
Bussing kit for 2 – 12-module racks
AUX30-48
30” Auxiliary Rack(s) for 48-module rack
APPLICATIONS
• Professional and educational theatre
• Production studios
• Concert and performance halls
• Themed retail and dining
• Multi-use Convention Centers
• Houses of Worship
FEATURES
• High dimmer density
• Up to two 2.4kW dimmers per module
• 6, 12, 24, and 48 module racks available
• Rugged industrial construction
• Installation flexibility
• Adaptable modular design
• 100,000A Short Circuit Current Rating (SCCR)
• Advanced configuration editing built into rack
• Stores up to 128 Presets in memory
• Direct Ethernet control signal input
• Two DMX512 inputs
• Standard system and rack monitoring with
diagnostic reporting
• Supports ETC Dimmer Doubling™
• All racks UL and cUL LISTED
ACCESSORIES
• SmartLink® Button Stations and SmartLink TimeClock
• Dimmer Doubler
• Sound Suppression Hood
• Floor pedestal for 24-module rack
• Document holder
AUX19-48
19” Auxiliary Rack(s) for 48-module rack
AUX19-24
19” Auxiliary Rack(s) for 24-module rack
AUX19-12
19” Auxiliary Rack(s) for 12-module rack
Vibration Reduction mounts available for all Sensor+ racks. Contact ETC for details
Note: Power feeds above 800A up to 2000A require addition of a 30” auxiliary rack.
*
Rack Accessories
Model
Description
SSSh24-48
Sensor+ Sound Suppression Hood – large
SSSh6-12
Sensor+ Sound Suppression Hood – small
Pedestal
Floor pedestal for 24-module rack
DH
Document Holder
SmartLink Accessories
Model
Description
S-LPB
SmartLink Power Board for Sensor+ Racks*
S-10005
SmartLink 5-Button Station*
S-10010
SmartLink 10-Button Station*
*One SmartLink Power Board required for station support.
S-LPB supports up to four stations.
Only one S-LPB may be enabled in a system.
1 of 4
ETC®
Sensor®+ Racks
Sensor+ Series
sp e ci f ic a t i o n s
Addi t i o n a l I n f o r m a t i o n
GENERAL
• Racks available in four sizes
-- SR6+
6 modules, 12 dimmers maximum
-- SR12+ 12 modules, 24 dimmers maximum
-- SR24+ 24 modules, 48 dimmers maximum
-- SR48+ 48 modules, 96 dimmers maximum
• Dual density (two dimmers per module), single density and
half density dimmer modules available
• Operating temperature: 0-40°C / 32-104°F
-- Dimmer room HVAC systems must at all times maintain
the specified ambient temperature at the dimmer rack.
Dimming systems operating within 10 degrees F of the
upper or lower temperature limits must strictly follow
installation and operation guidelines to operate reliably.
• Relative humidity: 30-90% non-condensing
• All racks UL and cUL LISTED
• UL924 LISTED for Bypass operation
MECHANICAL
• Rugged 16-gauge steel construction
• Fine-textured, scratch-resistant, epoxy paint
• SR6+ and SR12+ uses wall mount installation
• SR24+ can be wall or pedestal mounted
• SR48+ is floor mounted
• Top and bottom conduit access through removable panels
(SR48+) or knockouts (SR6+, SR12+, and SR24+)
• No tools required for module removal or installation
• Keyed module slots prevent insertion of inappropriate
module types
• Front access to all wiring and terminations
• Full height locking door
• Electrostatic air filter easily removed from door for
periodic cleaning
• High efficiency cooling system with airflow sensor
• High visibility LED status beacon
ELECTRICAL
• SR6+, SR12+ and SR24+ accept:
-- Three phase 120/208 VAC
-- Single phase 120/240 VAC
• SR48+ accepts
-- Three phase 120/208 VAC
• Line feed frequencies from 47-63Hz
• Line feed voltage range is 91-139 VAC*
• Load terminals accept up to #4 AWG (16mm2) wire (see chart)
• S hort Circuit Current Rating: 100.000A RMS symmetrical
@ 240VAC
• Auxiliary equipment racks and custom switchgear/distribution
available (Call ETC for details)
*Note:Suggested max main transformer tap 135V to allow for
line fluxuation.
CONTROL Electronics
• Sensor+ Control Electronics Module (CEM+)
• Single Ethernet control signal input
• Two DMX512 inputs
• S tandard diagnostic reporting via browser-based interface or
DimStat software
• Supports Dimmer Doubling™
• Supports SmartLink® control of presets
OPTIONS
• Advanced Features™ dimmer-specific load and diagnostic
reporting
• Amp-Trap® fuses to allow feeding individual racks from
oversize mains
• Bus kits available
• Vibration reduction kits available for all racks
• SmartLink Power Board
• SmartLink TimeClock
Compatible Dimmer Modules
Sensor Standard Modules
Model
Description
D15/D20
Dual 15A/20A Dimmer Module – 350μS
D15E/D20E
Dual 15A/20A Dimmer Module – 500μS
D50AF
Single 50A Dimmer Module – 500μS – AF
D100AF*
Half 100A Dimmer Module – 500μS – AF
Sensor Special purpose Modules
L10
Dual 10A Low Wattage Dimmer Module
L10F
Single 10A Low Wattage Fluorescent
Dimmer Module
D15F/D20F
Single 15A/20A Fluorescent Dimmer Module
R15/R20
Dual 15A/20A Relay Module
CC15/CC20
Dual 15A/20A Constant Circuit Breaker Module
AFM
Air Flow Module
*Half-density modules use two module slots
Control Modules
Model
Description
CEM+
Control Electronics Module +
Load Wiring Lug Capacity
Connection
WIre Size
10A, 15A, 20A, and 50A lugs
4 AWG Max. (16mm2)
100A lugs
2/0 Max.
Primary Feed Lug Capacity
Connection
WIre Size
SR48+
Dual 600 kcmil – 2 AWG
SR24+
Dual 350 kcmil – 4 AWG
SR12+
Dual 250 kcmil – 6 AWG
SR6+
Single 2/0 – 14 AWG
Sound Pressure Level (dBA)
MODEL
dBA @ 1000Hz (1kHz)*
WITHOUT
WITH SSSh**
SR48+
37.0
30.9
SR24+
40.2
34.0
SR12+
41.8
33.8
SR6+
26.0
21.4
*dBA values for each Sensor rack measured at 1 meter. Visit www.etcconnect.com for full
spectrum dBA ratings.
**Sensor Sound Supression Hood (SSSh)
2 of 4
ETC®
Sensor®+ Racks
Sensor+ Series
t y pic a l s y s t e m r is e r
Switch
DMX Plug-in
DMX
Booth
DMX Plug-in
DMX
SmartLink
Stage
Preset 1
Preset 2
Preset 3
Preset 6
Preset 7
Preset 8
Preset 1
Preset 4
Preset 9
Preset 5
Preset 10
Preset 2
Preset 3
Preset 1
Preset 6
Preset 4
Preset 2
Preset 7
Preset 5
Preset 3
Preset 8
Preset 1
Preset 4
Preset 9
Preset 5
Preset 10
Preset 2
Preset 3
Preset 4
Preset 5
Congo jr Console
Sensor+ Dimming System
T y pic a l n e t w o r k r is e r
Link Power
Aux Power
Unison Control Stations
Link Power
PC for ETC software
CMEi in
ER4 Rack
Switch
Radio Focus
Remote
(Transmitter)
Eos Remote Video Interface
Eos Console
DMX
Net3 DMX Gateway
Net3 DMX Gateway
DMX from
external source
Sensor+ Dimming System
Radio Focus
Remote
(Receiver)
3 of 4
To moving lights
or any DMX device
ETC®
Sensor®+ Racks
Sensor+ Series
ph y sic a l
Empty Dimmer Rack Weights
model
weight
shipping weight
lbs
kgs
lbs
kgs
188
86
198
90
SR48+ Door
31
14
35
SR24+
107
49
115
*
17
8
20
SR12+
45
21
50
23
SR12+ Door*
11
5
14
6.5
SR6+ with Door
36
16
45
21
SR48+
*
SR24+ Door
Installation Rack Dimensions
Model
Height
Width
Depth
inches
mm
inches
mm
inches
mm
SR48+
83.1
2110
14.6
370
22.8
580
16
SR24+
45.8
1160
14.6
370
16.8
430
53
SR12+
25.8
660
14.6
370
13.3
340
9
SR6+
16.4
420
14.6
370
13.3
340
Rack doors ship separately
*
SR48+
Full Dimmer Rack Weights
model
Max. weight
Typical weight
lbs
kgs
lbs
kgs
SR48+
493
224
459
209
SR24+
261
119
244
111
SR12+
115
53
105
48
SR6+
71
33
66
30
Maximum – D100AF modules (11.7lbs/slot)
*
All racks
require minimum
clearance
above fan
10.0”
250mm
83.1”
2110mm
SR24+
Typical – D20 modules (5lbs/slot)
Refer to module datasheets to calculate rack weight for other module types
45.8”
1160mm
SR12+
25.8”
660mm
SR6+
16.4”
420mm
Wall or
other
barrier
(all racks)
14.6”
370mm
14.6”
370mm
13.3”
340mm
6”
150mm
13.3”
340mm
17”
460mm
17”
460mm
14.6”
370mm
14.6”
370mm
6”
150mm
6”
150mm
16.8”
430mm
22.8”
580mm
17”
460mm
6”
150mm
17”
460mm
Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736
London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000
Rome, IT • Via Pieve Torina, 48, 00156 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486
Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00
Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325
Web • www.etcconnect.com • Copyright©2010 ETC. All Rights Reserved. All product information and specifications subject to change. 7151L1001 Rev. G Printed in USA 10/10
Sensor® products protected by one or more of the following U.S. Patent Numbers 5,323,088, 5,352,088, 7,233,112, 7,019,469, 6,849,943, and 6,002,563; European Number 0603333T2; German 69203609.
4 of 4
ETC
Standard Dimmer Module
Standard Series
nal
Sig
D20
nal
Sig
G e n e r a l I n f o r m at i o n
O r d e r i n g i n f o r m at i o n
The Standard Dimmer Module is designed for use in both Sensor®+
and Unison® Dimming Series modular rack enclosures. Standard
Dimmer Modules provide cost-effective digital forward phase angle
dimming for standard loads such as incandescent, low voltage,
quartz, neon, cold-cathode and 2 and 4-wire fluorescent ballasts. The
patented, high-density, dual modules feature modular installation
and removal, fully magnetic circuit breakers and standard or
enhanced risetime toroidal filters.
100-120V Standard Dimmer Modules
APPLICATIONS
• Incandescent lighting
• Low voltage lighting
• Quartz lighting
• Neon lighting
• Cold Cathode lighting
• 2-wire Fluorescent ballast
• 4-wire Fluorescent ballast
FEATURES
• Two 1.8 or 2.4kW dimmers per module
• Standard or Enhanced risetime toroidal filters
• High-density modular assembly
• Die-cast aluminum chassis
• Fully magnetic circuit breakers
General
• 100,000A Short Circuit Current Rating (SCCR)
• UL and cUL LISTED
Model
Description
D15
Dual 15A Dimmer Module, 350μS
D15E
Dual 15A Dimmer Module, 500μS
D20
Dual 20A Dimmer Module, 350μS
D20E
Dual 20A Dimmer Module, 500μS
AFM
Air Flow Module
Compatible Systems
Model
Description
Sensor+ Installation Racks*
SR6+
Sensor+ 6 module rack
SR12+
Sensor+ 12 module rack
SR24+
Sensor+ 24 module rack
SR48+
Sensor+ 48 module rack
SR6AF+
Sensor+ 6 module Advanced Features rack
SR12AF+
Sensor+ 12 module Advanced Features rack
SR24AF+
Sensor+ 24 module Advanced Features rack
SR48AF+
Sensor+ 48 module Advanced Features rack
SRAFN+
Sensor+ GFCI racks
Sensor+ Touring Racks
SP4820+
Sensor+ 24 module Touring Rack (48-20A dimmers)
SP9620+
Sensor+ 48 module Touring Rack (96-20A dimmers)
Sensor+ Portable Packs
SP1220+
Sensor+ 6 module Portable Pack (12-20A dimmers)
SP1215+
Sensor+ 6 module Portable Pack (12-15A dimmers)
SP2420+
Sensor+ 12 module Portable Pack (24-20A dimmers)
SP2415+
Sensor+ 12 module Portable Pack (24-15A dimmers)
Rack enclosures also available for 230CE and 240 Volt applications
*
1 of 2
ETC
Standard Dimmer Module
Standard Series
sp e ci f ic a t i o n s
physical
GENERAL
• UL and cUL Listed for continuous duty at 100% of rated load
-- D15/D15E – 1.8kW
-- D20/D20E – 2.4kW
PHYSICAL
• Modular plug-in assemblies
• Cast aluminum chassis, finished with textured epoxy paint
• Keyed to prevent insertion in inappropriately rated rack
positions
CIRCUIT BREAKERS
• Fully magnetic to eliminate nuisance tripping
• 20x inrush current rating
• 125%, 10-120 seconds, must-trip rating
• Rated for 100% switching duty applications
RATINGS
• 100,000A Short Circuit Current Rating Rating (SCCR)
• Modules withstand hot-patching of cold loads up to full
rating
• UL and cUL LISTED
Power Device
• Sealed, patented assembly
• Field replaceable with screwdriver
• Two back-to-back SCRs per circuit
• One control LED per circuit
• 4000V isolation between control and power components
• Integral bonded heatsink
• Integral temperature sensor
FILTERING
• High quality toroidal filters
-- 350μS risetime - Standard 100-120V modules*
-- 500μS risetime - Enhanced 100-120V modules*
Module Dimensions
*Risetime measured at full load, at worst case firing angle (90 degrees), from 1090% of output wave form
Dimmer room HVAC systems must at all times maintain the specified ambient
temperature at the dimmer rack. Dimming systems operating within 10°F of the
upper or lower temperature limits must strictly follow installation and operation
guidelines to operate reliably.
Model
Height
Width
Depth
inches
mm
inches
mm
inches
mm
D15
1.5
38.
11.8
300
4.9
127
D15E
1.5
38
11.8
300
4.9
127
D20
1.5
38
11.8
300
4.9
127
D20E
1.5
38
11.8
300
4.9
127
Module Weights
model
weight
lbs
shipping weight
kgs
lbs
kgs
D15/D20
5.0
2.3
6.9
3.1
D15E/D20E
5.5
2.5
6.9
3.1
Maximum BTU Production per module
model
BTUs
Watts
Efficiency
D15
380
112
96.9%
D15E
474
140
96.1%
D20
522
154
96.8%
D20E
810
238
95.0%
These values should be provided to a qualified HVAC design engineer, along with
dimmer quantities, types and dimmer room dimensions, to calculate dimmer room
air handling requirements.
DIMMER RANGE
• Incandescent, low voltage dimming range 100-0%
• Dimming range of 2 and 4-wire fluorescent ballast is
dependent on lamp ballast combination. Contact ETC for
range verification
• Sizing of Neon transformer used in dimming applications
should be 1.5x greater than size used in non-dimming
application
SCR Rating
moDULE
Single cycle peak surge current
Half cycle peak surge current
Transient over voltage
D15/D20
625A
1620A
600V
Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736
London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000
Rome, IT • Via Ennio Quirino Visconti, 11, 00193 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486
Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00
Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325
Web • www.etcconnect.com • Copyright©2008 ETC. All Rights Reserved. All product information and specifications subject to change. 7050L1028 Rev. D Printed in USA 10/08 Sensor® products protected by one or more of the following U.S. Patent Numbers 5,323,088, 5,352,088, 7,233,112, 7,019,469, 6,849,943, and 6,002,563; European Number 0603333; German 69203609.
2 of 2
ETC
Unison® Heritage™ Button Station
Unison Control Series
O r d e r i n g i n f o r m at i o n
Button Stations
G e n e r a l I n f o r m at i o n
Elegant and clean-lined, Unison Heritage controls are designed to
complement – not to compete with – the aesthetics of any interior
environment, while being easy to install using LinkConnect. Artful
but durable, Heritage stations are engineered to stand up to the daily
abuse of busy public areas. The Unison Heritage series of button
control stations can be customized to suit any décor and application
– available in a wide range of sizes, colors and configurations.
Choose from pre-configured button combinations or put stations
together to create endless combinations of controls.
APPLICATIONS
• Churches
• Hotels
• Convention Centers
• Meeting Rooms
• Schools
• Restaurants
FEATURES
• LinkConnect – using Echelon’s LonTalk® protocol with
LinkPower, the two wire topology-free system gives you the
freedom to put stations where you need them
• Fastener Free Faceplate System – no visible means
of attachment
• ColorCondition – RGB LED’s allow for customized control
indication on a per button basis, unlocking the conditional
logic capabilities of a Paradigm control system
• Forever Legend System – complimentary colored standard
or custom legend options using an indelible, laser-marking
method
• RemoteDirect – a built in InfraRed (IR) receiver on every
station allows for optional IR remote control at every station
• LockOut – configurable control lockout from the push of
a button
• Take Control – set the faders on a Heritage fader station and
then choose when to gain control of the lighting in a room,
at exactly the right moment
model
description
Legend
UH00001- __1F
1/2 gang, 1 button
On/Off
UH00002- __1F
1/2 gang, 2 button
On, Off
UH00005- __1F
1/2 gang, 5 button
Preset 1-4, Off
UH10001- __1F
1 gang, 1 button
On/Off
UH10001- __2F
1 gang, 1 button
Entry
UH10001- __3F
1 gang, 1 button
Panic
UH10002- __1F
1 gang, 2 button
On, Off
UH10002- __2F
1 gang, 2 button
Open, Close
UH10005- __1F
1 gang, 5 button
Preset 1-4, Off
UH10007- __1F
1 gang, 7 button
Raise, Lower,
Preset 1-4, Off
UH10010- __1F
1 gang, 10 button
Preset 1-9, Off
UH11K00- __1F
1 gang, 1 keyswitch
(maintained*)
Lockout
UH11K01- __1F
1 gang, 1 keyswitch
(maintained*), 1 button
Lockout, On/Off
UH11K01- __2F
1 gang, 1 keyswitch
(maintained*), 1 button
Lockout, Entry
UH11K01- __2F
1 gang, 1 keyswitch
(maintained*), 1 button
Lockout, Panic
UH11K02- __1F
1 gang, 1 keyswitch
(maintained*), 2 button
Lockout, On, Off
UH11K02- __2F
1 gang, 1 keyswitch
(maintained*), 2 button
Lockout, Open,
Close
UH11K05- __1F
1 gang, 1 keyswitch
(maintained*), 5 button
Lockout, Preset
1-4, Off
*Keyswitch stations available in momentary configurations.
Notes:
Enter station color code in __ space provided:
1 = Cream (RAL 9001)
2 = Ivory (RAL 1015)
3 = Gray (RAL 7001)
4 = Black (RAL 9004)
5 = Signal White (RAL 9003)
Above stations flush mount (F) in industry standard gang boxes. (By Others)
Also available in surface mount (S) and portable (P) configurations. (Contact ETC)
1 of 2
ETC
Unison® Heritage™ Button Station
Unison Control Series
sp e ci f ic a t i o n s
physical
GENERAL
• UL and cUL LISTED
• CE Marked
FUNCTIONAL
• Button and keyswitch functions include: preset selection,
record mode activation, station lockout, raise, lower, macro
activation, zone on/off control, timed event override and wall
open/close or toggle
• Custom button functionality programmable via LightDesigner
configuration software
• Programmable electronic lockout levels
• Allows for programming of individual lockout levels
MECHANICAL
• Standard configurations with 1, 2, 5, 7 and 10 buttons
or 0,1,2,and 5 buttons with a maintained or momentary
keyswitch
• Custom button stations available, contact ETC
• Gangable for custom applications
• Enclosed electronics assembly and faceplate included
• Cantilevered switch arrays with removable caps
• No visible means of attachment
• Flush mount in industry standard back box, RACO 690
or equivalent
• Surface mount back-boxes available from manufacturer
• Constructed of injection molded, ABS plastic in five standard
colors, matched to RAL standard colors
• Custom colors available with sample
• Indelibly marked legends in a contrasting color
• Integral RGB LED response indicator for each button
• Integrated IR receiver
ELECTRICAL
• Connect via Echelon® LinkPower control network utilizing low
voltage Class II wiring
• Topology free and polarity independent wiring over Belden
8471 or equivalent and (1) #14 ESD drain wire
• Wiring may be bus, loop, home-run or any combination
of these
• All station terminations are connectorized
• UL and cUL LISTED, CE marked
THERMAL
• Ambient room temperature: 0-40°C / 32-104°F
• Ambient humidity: 30-90% non-condensing
Flush Backbox Dimensions*
Gang
Height
Width
Depth
inches
mm
inches
mm
inches
mm
1/2
3.75
95.3
1.3
33
3.25
82.6
1
3.75
95.3
2.0
50.8
2.5
63.5
1 Gang flush mount back box RACO 690
1/2 Gang flush mount back box provided by ETC
Surface Backbox Dimensions*
gang
Height
inches
Width
mm
inches
Depth
mm
inches
mm
1/2
3.75
95.3
1.75
44.5
3.25
82.6
1
3.75
95.3
2.0
50.8
2.5
63.5
Surface mount back boxes provided by ETC
Faceplate Dimensions*
gang
*
Height
Width
inches
mm
inches
mm
1/2
4.5
114.3
1.75
44.5
1
4.5
114.3
2.8
71
Dimensions typical
Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736
London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000
Rome, IT • Via Ennio Quirino Visconti, 11, 00193 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486
Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00
Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325
Web • www.etcconnect.com • Copyright©2008 ETC. All Rights Reserved. All product information and specifications subject to change. 7181L1002 Rev. A Printed in USA 09/08
Unison® products protected by one or more of the following U.S. Patenten Numbers 5,323,088, 5,352,958 and 6,849,943; European Pateten Number 0603333; German Patent Number 69203609; US and International patents pending
2 of 2
ETC
Unison® Heritage™ Fader Stations
Unison Control Series
O r d e r i n g i n f o r m at i o n
Heritage Fader Stations
Model
description
Legend
UH10100- __1F
1 gang, 1 fader
Master
UH10101- __1F
1 gang, 1 fader,
1 button
Master, On/Off
UH10101- __2F
1 gang, 1 fader,
1 button
Master, Entry
UH10101- __3F
1 gang, 1 fader,
1 button
Master, Panic
UH10102- __1F
1 gang, 1 fader,
2 buttons
Master, Open, Close
UH10102- __2F
1 gang, 1 fader,
2 buttons
Master, On, Off
G e n e r a l I n f o r m at i o n
UH10105- __1F
1 gang, 1 fader,
5 buttons
Master, Preset 1-4, Off
Elegant and clean-lined, Unison Heritage controls are designed
to complement – not to compete with – the aesthetics of any
interior environment, while being easy to install using LinkConnect.
Artful but durable, Heritage stations are engineered to stand up
to the daily abuse of busy public areas. The Unison Heritage series
of button/fader control stations can be customized to suit any
décor and application – available in a wide range of sizes, colors
and configurations. Choose from pre-configured button/fader
combinations or put stations together to create endless combinations
of controls.
UH30407- __1F
3 gang, 4 fader,
7 buttons
Manual, Record, Master,
Zone 1-3, Preset 1-4, Off
UH30412- __1F
3 gang, 4 fader,
12 buttons
Manual, Record, Master,
Zone 1-3, Preset 1-9, Off
UH40707- __1F
4 gang, 7 fader,
7 buttons
Manual, Record, Master,
Zone 1-6, Preset 1-4, Off
UH40712- __1F
4 gang, 7 fader,
12 buttons
Manual, Record, Master,
Zone 1-6, Preset 1-9, Off
UH51007- __1F
5 gang, 10 fader, Manual, Record, Master,
7 buttons
Zone 1-9, Preset 1-4, Off
UH51012- __1F
5 gang, 10 fader, Manual, Record, Master,
12 buttons
Zone 1-9, Preset 1-9, Off
UH61307- __1F
6 gang, 13 fader, Manual, Record, Master,
7 buttons
Zone 1-12, Preset 1-4, Off
UH61312- __1F
6 gang, 13 fader, Manual, Record, Master,
12 buttons
Zone 1-12, Preset 1-9, Off
UH71607- __1F
7 gang, 16 fader, Manual, Record, Master,
7 buttons
Zone 1-15, Preset 1-4, Off
UH71612- __1F
7 gang, 16 fader, Manual, Record, Master,
12 buttons
Zone 1-15, Preset 1-9, Off
APPLICATIONS
• Churches
• Hotels
• Convention Centers
• Meeting Rooms
• Schools
• Restaurants
FEATURES
• LinkConnect – using Echelon® LonTalk® protocol with
LinkPower, the two wire topology-free system gives you the
freedom to put stations where you need them
• Fastener Free Faceplate System – no visible means
of attachment
• ColorCondition – RGB LED’s allow for customized control
indication on a per button or fader basis, unlocking the
conditional logic capabilities of a Unison control system
• Forever Legend System – complimentary colored standard
or custom legend options using an indelible, laser-marking
method
• RemoteDirect – built in InfraRed (IR) receivers on every station
allow for optional IR remote control at every station location
• RealFade – physical slider controls for groups or zones with 1
to 16 faders per station, paired with up to 12 buttons
• LockOut – configurable control lockout from the push of
a button
• Take Control – preset the faders on a Heritage fader station
and then choose when to gain control of the lighting in a
room, at exactly the right moment
Enter station color code in __ space provided.
1 = Cream (RAL 9001)
2 = Ivory (RAL 1015)
3 = Gray (RAL 7001)
4 = Black (RAL 9004)
5 = Signal White (RAL 9003)
Above stations flush mount (F) in industry standard gang boxes. (By Others)
Also available in surface mount (S) and portable (P) configurations. (Contact ETC)
1 of 2
ETC
Unison® Heritage™ Fader Stations
Unison Control Series
sp e ci f ic a t i o n s
physical
FUNCTIONAL
• UL and cUL LISTED
• CE Marked
FUNCTIONAL
• Operate default or custom system functions including preset
selection, manual mode activation, record mode activation,
station lockout, raise, lower, sequence control, zone on/off,
room combine, macro activation and timed event override
• Fader functions include master, zone, fade rate, or preset
• Custom button and fader functionality programmable via
LightDesigner configuration software
• Programmable electronic lockout levels
• Buttons allow programming of individual lockout levels.
MECHANICAL
• Standard configurations with 7 or 12 buttons and 4, 7, 10,
13 or 16 faders
• Support for 1-12 buttons and 1-16 faders for custom
applications, contact ETC
• Enclosed electronics assembly
• Faceplate with no visible means of attachment
• 45mm slide potentiometer faders and cantilevered switch
arrays with removable caps
• Flush mount in industry standard back boxes
• Surface mount back boxes available from manufacturer
• Constructed of injection molded, ABS plastic in five standard
colors, matched to RAL standard colors
• Custom colors available with sample
• Indelibly marked legends in a contrasting color
• Integral RGB LED response indicator for each
button and fader
• Integrated IR receiver
ELECTRICAL
• Connect via Echelon® LinkPower® control network utilizing
low voltage Class II wiring
• Topology free and polarity independent wiring over Belden
8471 or equivalent, and (1) #14 ESD drain wire
• Wiring may be bus, loop, home-run or any combination
of these
• All station terminations are connectorized.
• UL and cUL LISTED, CE marked
THERMAL
• Ambient room temperature: 0-40°C / 32-104°F
• Ambient humidity: 30-90% non-condensing
Flush Backbox Dimensions*
gang
Height
Depth
mm
inches
mm
inches
mm
1 (RACO 690*)
3.75
95.3
2.0
50.8
2.5
63.5
3 (RACO 692 )
3.75
95.3
6.4
162.6
2.5
63.5
4 (RACO 693 )
3.75
95.3
8.2
208.3
2.5
63.5
5 (RACO 694*)
3.75
95.3
10.0
254.0
2.5
63.5
6 (RACO 695 )
3.75
95.3
11.8
299.7
2.5
63.5
7 (by ETC)
3.75
95.3
13.6
345.4
2.5
63.5
*
*
*
*
Width
inches
Or equivalent
Surface Backbox Dimensions*
gang
Height
inches
*
mm
Width
inches
mm
Depth
inches
mm
1
4.6
116.8
2.9
73.7
2.5
63.5
3
4.6
116.8
6.9
175.3
2.5
63.5
4
4.6
116.8
8.7
221.0
2.5
63.5
5
4.6
116.8
10.5
266.7
2.5
63.5
6
4.6
116.8
12.3
312.4
2.5
63.5
7 (by ETC)
4.6
116.8
14.1
358.1
2.5
63.5
Surface mount back boxes provided by ETC
Faceplate Dimensions*
gang
Height
inches
*
mm
Width
inches
mm
1
4.5
114.3
2.8
71.1
3
4.5
114.3
6.7
170.2
4
4.5
114.3
8.6
218.4
5
4.5
114.3
10.4
264.2
6
4.5
114.3
12.2
309.9
7
4.5
114.3
14.0
355.9
Weights and dimensions typical
Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736
London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000
Rome, IT • Via Ennio Quirino Visconti, 11, 00193 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486
Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00
Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325
Web • www.etcconnect.com • Copyright©2008 ETC. All Rights Reserved. All product information and specifications subject to change. 7181L1001 Rev. A Printed in USA 09/08 Unison® products protected by one or more of the following U.S. Patenten Numbers 5,323,088, 5,352,958 and 6,849,943; European Pateten Number 0603333; German Patent Number 69203609; US and International patents pending
2 of 2
ETC®
Unison® Paradigm® ControlDesigner™
Unison Software Series
G e n e r a l I n f o r m at i o n
g e n e r a l i n f o r m at i o n
Companion to LightDesigner™, ControlDesigner software gives you
the tools to create the look of your Touchscreen pages and other user
interfaces, pre-visualizing your control interface. Free for download
from ETC’s Web site www.etcconnect.com, ControlDesigner lets
you choose from built-in graphics or build your own as you develop
unique interfaces ahead of time and load them when you are ready.
Change the look of the graphics by selecting from a variety of
convenient ready-made themes, or easily design your own.
Features
• DesignView – create and edit control pages using buttons,
faders, custom pages, pop-up windows, background images,
animated clocks, transparent buttons, and navigation controls
with animated page transitions, add pages to create and edit
timed events within your system
• ControlView – simulate each page, and the page transitions
before uploading to the system
• ThemeBuilder – design pages using standard graphics, then
change the “skin” using built-in or custom graphics
• Secure-It Touch – automatically create numeric passwordentry pages, protecting any page or control from access
Applications
• Churches
• Schools
• Restaurants
• Hotels
• Museums
• Casinos
• Ballrooms
Minimum Computer Requirements
• Windows 7 (Home Premium) or XP (Pro SP2) or better
• 2 GHz Pentium 4 processor or better (Dual or Quad core
recommended)
• 1 GB of available hard drive space
• 1 GB of RAM or better (2GB recommended)
• Video Card capable of 1024x768 resolution
(1280x1024 recommended)
• Open GL Graphics Acceleration
• Ethernet Port
• USB Port or SD card slot
• Keyboard and Mouse
1 of 2
ETC
Unison® Paradigm® ControlDesigner™
Unison Software Series
sp e ci f ic a t i o n s
sp e ci f ic a t i o n s
The Unison Paradigm ControlDesigner software program shall be an
application software package that facilitates off-line Unison Paradigm
Touchscreen station configuration
• Software setup shall include Configuration and Design
Wizards, to create a graphical representation of a
control environment
• The software program shall be downloadable from the
manufacturer’s website free of charge
Functions
• Provides functionality to create and modify Pages for display
on a specific type of Touchscreen Station
• There shall be a wizard to assist with the creation of Pages
• A single configuration for an Touchscreen Station shall be
defined as a set of one or more Pages
• Each Page shall have a background that may incorporate
multiple images or animations
• Pop-ups can be shown/hidden over any Page in a
Configuration and more than one Popup can be shown
at once
• Pages may have multiple design elements that may be
Controls, Indicators or both
• Design elements shall have a user-defined size, position and
z-order that cannot be changed from within the System
• Each design element shall have between 1 and 256 states,
each of which can have a distinct appearance
• The appearance of a state can be taken from a Theme or
imported image file
• There shall be support for import of JPEG and PNG
image formats
• Transparency shall be supported
• Animated images shall be supported
• Transitions between states of design elements can
be animated
• Page transitions can be animated
• Design elements shall have a visibility group and threshold
• Design elements that are Controls shall have a lockout group
and threshold
• All text shall have a user-definable font family, size, color
and alignment
• There shall be at least the following types of design elements
-- Label
-- Level Indicator
-- Button
-- Fader (straight and curved)
-- Clock (analog and digital)
-- Numeric Keypad
-- Tab
-- Pages
-- Pop-ups
-- Frames
• Pop-ups can be any fixed size up to the Page size
• P op-ups will have a fixed position on screen (but may move
when being shown/hidden)
• Themes shall define a collection of consistent appearances
and sounds for design elements
• It shall be possible to change the Theme used for a particular
Station without modifying the underlying design elements
• There shall be tools to assist with the creation of new Themes
• Shall allow sounds to be associated with a particular Page
• S hall allow sounds to be associated with state transitions of
particular design elements
• S ounds may be used to provide Touchscreen
interaction feedback
• A Page can be designated as the Station inactivity Page
• A Page can have a lockout group and threshold
• A Tab can have a visibility group and threshold
• There shall be a visualization interface for Page creation
and editing
• S tandard graphical interaction methods (drag-and-drop) shall
be used to arrange design elements on Pages
• There shall be a layout grid with user-defined spacing and
color with associated snap-to-grid functionality
• It shall be possible to reuse the graphical layout of a
configuration independent of any assigned functionality
• The Touchscreen design functionality shall be part of a
separate application that can be used alongside LightDesigner
Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736
London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000
Rome, IT • Via Ennio Quirino Visconti, 11, 00193 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486
Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00
Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325
Web • www.etcconnect.com • Copyright©2010 ETC. All Rights Reserved. All product information and specifications subject to change. 7180L1006 Rev. C Printed in USA 06/10
Unison® products protected by one or more of the following: U.S. Patent No. 5,323,088, 6,849,943, and 5,352,958; European Patent No. 0603333; German Patent No. 69203609; US and International patents pending
2 of 2
ETC
Outlet Boxes
Distribution Series
G E N E R A L I N F O R M AT I O N
O R D E R I N G I N F O R M AT I O N
Outlet boxes are designed for surface or recess mounting
in theatres, television studios and other spaces for
distribution of lighting circuits.
FEATURES
PHYSICAL
# of
Outlets
Surface and recess mounting available
1, 2, 3, 4, 5, 6, and 8 connectors
Panel mount connector Options:
Edison (20A)
Stage Pin (20, 60 and 100 amp)
Grounded Twist-Lock (20A)
Over- and Under-hung U-bolt and C-clamp pipe
mount options available
UL and cUL Listed
Fabricated from 18-gauge steel with 16-gauge
covers and 14-gauge end caps
Finished with fine-textured, scratch-resistant,
black powder coat
2” or 3/4” labels with white numbers on black
background (sized to match product)
Pin outlets spaced on 1.25” or 3” centers
Edison or Twist-Lock outlets spaced on 3”
centers only
Back box
Dimensions
9100 Panel
Widths
9200 Panel
Widths
PIN
1.25”
1
2,3,4
5,6
8
3” W x 6.25” H x 3.25” D
6” W x 6.25” H x 3.25” D
9” W x 6.25” H x 3.25” D
12” W x 6.25” H x 3.25” D
3”
6”
9”
12”
4”
7”
10”
13”
Other
3.00”
1,2
3,4
5,6
8
6” W x 6.25” H x 3.25” D
12” W x 6.25” H x 3.25” D
18” W x 6.25” H x 3.25” D
24” W x 6.25” H x 3.25” D
6”
12”
18”
24”
7”
13”
19”
25”
Standard Surface Mount Outlet Boxes
Outlet Qty
Edison
Pin 3”
Pin 1.25”
Twistlock
1
2
3
4
5
6
8
9101A
9102A
9103A
9104A
9105A
9106A
9108A
9101B
9102B
9103B
9104B
9105B
9106B
9108B
9101BD
9102BD
9103BD
9104BD
9105BD
9106BD
9108BD
9101C
9102C
9103C
9104C
9105C
9106C
9108C
Standard Recessed Mount Outlet Boxes
Outlet Qty
Edison
Pin 3”
Pin 1.25”
Twistlock
1
2
3
4
5
6
8
9201A
9202A
9203A
9204A
9205A
9206A
9208A
9201B
9202B
9203B
9204B
9205B
9206B
9208B
9201BD
9202BD
9203BD
9204BD
9205BD
9206BD
9208BD
9201C
9202C
9203C
9204C
9205C
9206C
9208C
To any 9100 series box, add “-U” (U-Bolt) or “-C” (C-clamp) after the connector
type to indicate pipe mount option. For example, 9104B-U indicates surface mount,
4-outlet box with stage pin connectors and U-bolt pipe mounting kit.
Pigtail Boxes
Distribution Series
G E N E R A L I N F O R M AT I O N
O R D E R I N G I N F O R M AT I O N
Pigtail boxes are designed for surface or recess mounting
in theatres, television studios and other spaces for
distribution of lighting circuits.
FEATURES
PHYSICAL
# of
Pigtails
Surface and recess mounting available
1, 2, 3, 4, 5, 6, and 8 connectors
18”, 24” and 36” pigtails standard
Connector Options:
Edison (20A)
Stage Pin (20, 60 and 100 amp)
Grounded Twist-Lock (20A)
Over- and Under-hung U-bolt and C-clamp pipe
mount options available
UL and cUL Listed
Fabricated from 18-gauge steel with 16-gauge
covers and 14-gauge end caps
Finished with fine-textured, scratch-resistant,
black powder coat
2” or 3/4” labels with white numbers on black
background (sized to match product)
Pin pigtails spaced on 1.25” or 3” centers
Edison or Twist-Lock pigtails spaced on 3”
centers only
Back box
Dimensions
9300 Panel
Widths
9400 Panel
Widths
PIN
1.25”
1
2,3,4
5,6
8
3” W x 6.25” H x 3.25” D
6” W x 6.25” H x 3.25” D
9” W x 6.25” H x 3.25” D
12” W x 6.25” H x 3.25” D
3”
6”
9”
12”
4”
7”
10”
13”
Other
3.00”
1,2
3,4
5,6
8
6” W x 6.25” H x 3.25” D
12” W x 6.25” H x 3.25” D
18” W x 6.25” H x 3.25” D
24” W x 6.25” H x 3.25” D
6”
12”
18”
24”
7”
13”
19”
25”
Standard Surface Mount Pigtail Boxes
Outlet Qty
Edison
Pin 3”
Pin 1.25”
Twistlock
1
2
3
4
5
6
8
9301A
9302A
9303A
9304A
9305A
9306A
9308A
9301B
9302B
9303B
9304B
9305B
9306B
9308B
9301BD
9302BD
9303BD
9304BD
9305BD
9306BD
9308BD
9301C
9302C
9303C
9304C
9305C
9306C
9308C
Standard Recessed Mount Pigtail Boxes
Outlet Qty
Edison
Pin 3”
Pin 1.25”
Twistlock
1
2
3
4
5
6
8
9401A
9402A
9403A
9404A
9405A
9406A
9408A
9401B
9402B
9403B
9404B
9405B
9406B
9408B
9401BD
9402BD
9403BD
9404BD
9405BD
9406BD
9408BD
9401C
9402C
9403C
9404C
9405C
9406C
9408C
To any 9300 series box, add “-U” (U-Bolt) or “-C” (C-clamp) after the connector
type to indicate pipe mount option. For example, 9304B-U indicates a surface
mount box with 4-18” pigtails and stage pin connectors plus a U-bolt pipe
mounting kit.
Floor / Wall Pockets
Distribution Series
G E N E R A L I N F O R M AT I O N
Floor and Wall Pockets are designed for recess mounting
in floors and walls of theatres, television studios and
other spaces for distribution of lighting circuits.
FEATURES
FLOOR
POCKET
WALL
POCKET
1, 2, 3, 4, 5, and 6 connectors
Connector Options:
Edison (20A)
Stage Pin (20, 60 and 100 amp)
Grounded Twist-Lock (20A)
UL and cUL Listed enclosure
3/8” cast iron hinged cover with a non-skid
tread pattern and cable notches
3/4” labels with white numbers on black
background
Fabricated from 18-gauge steel
with 16 gauge covers
Finished with fine-textured, scratch-resistant,
black powder coat
3/4” reverse-screened white-on-black
polycarbonate adhesive labels
O R D E R I N G I N F O R M AT I O N
Standard Floor Pockets
Model#
Description
8501
8502
8503
8504
8505
8506
Floor
Floor
Floor
Floor
Floor
Floor
pocket,
pocket,
pocket,
pocket,
pocket,
pocket,
1
2
3
4
5
6
outlet
outlets
outlets
outlets
outlets – Pin & Edison only
outlets – Pin only
Standard Wall Pockets
Model#
Description
9601
9602
9603
9604
9605
9606
Recess
Recess
Recess
Recess
Recess
Recess
Wall
Wall
Wall
Wall
Wall
Wall
pocket,
pocket,
pocket,
pocket,
pocket,
pocket,
1
2
3
4
5
6
outlet
outlets
outlets
outlets
outlets – Pin only
outlets – Pin only
Add A (Edison), B (Stage Pin) or C (Twist lock) to part number to indicate connector
type. For example, 9504B indicates a floor pocket with 4 stage pin connectors.
Part numbers refer to 20A outlets; consult factory for alternate configurations.
NEMA Panels
Distribution Series
G E N E R A L I N F O R M AT I O N
O R D E R I N G I N F O R M AT I O N
An alternative to surface and recessed outlet boxes,
NEMA Panels are designed for recessed mounting in
discreet small spaces or existing back boxes – balcony
rails and orchestra pits.
Standard NEMA Outlet Panels
Model#
9801B
9802B
9803B
9804B
9801C
9802C
9803C
9801A
9802A
9803A
9804A
NEMA panels are designed for use with customer-supplied
industry standard electrical back boxes.
FEATURES
PHYSICAL
1, 2, 3, and 4 connectors
20A Connector Options:
Edison
Stage Pin
Grounded Twist-Lock
UL and cUL Listed
Fabricated of .125 aluminum
Finished with fine-textured, scratch-resistant,
black powder coat
Custom finishes available
3/4” labels with white numbers on black
background
Surface mount back box available (3.5” deep)
Stage Pin Panel, 1 outlet
Stage Pin Panel, 2 outlets
Stage Pin Panel, 3 outlets
Stage Pin Panel, 4 outlets
Twist-Lock Panel, 1 outlet
Twist-Lock Panel, 2 outlets
Twist-Lock Panel, 3 outlets
Edison Panel, 1 outlet
Edison Panel, 2 outlets
Edison Panel, 3 outlets
Edison Panel, 4 outlets
Americas
■
Europe
Unit 5, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK ■ Tel: +44 (0)20 8896 1000 ■ Fax: +44 (0)20 8896 2000
Asia
■
■
3030 Laura Lane, P.O. Box 620979, Middleton, WI 53562-0979 USA
Description
■
■
695
696
697
698
695
697
699
695
696
697
698
Tel: +1 608 831 4116 ■ Fax: +1 608 836 1736 ■ Toll free: 800 688 4116 ■ Toll free fax: 800 555 8912
Room 605-606, Tower III Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong ■ Tel: +852 2799 1220 ■ Fax: +852 2799 9325
Web: www.etcconnect.com
RACO Back
Box Part #
Email: (US) mail@etcconnect.com ■ (UK) mail@etceurope.com ■ (Asia) mail@etcasia.com
Copyright © 2003 ETC. All Rights Reserved. All product information and specifications subject to change. 7099L1004 Rev. A Printed in USA 04/03