Association BACnet France
Transcription
Association BACnet France
BACnet France Journal Le Latitude 20 à Paris 16 BACnet Forum Paris 55 01 04/07 Architecture BACnet /IP au Latitude 20 BACnet/IP architecture in Paris 16 Une introduction à BACnet An Introduction to BACnet 25 Tests de conformité à partir de 2007 BACnet Test Framework 41 Sept raisons de devenir membre Seven Reasons for Becoming a Member 50 Association BACnet France DESIGO™ ensures that everything is under control. User-friendly solutions are a must: DESIGO™ – the ingeniously designed building automation and control system offers ease of operation in the proper sense of the word. The operator units feature straightforward menu-driven operation and full graphic displays. The result: Short training times for operating staff, optimum system usage and targeted actions should faults occur, independent of time and location, through Web technology. Easy to use – powered by DESIGO™ Please contact: Siemens Switzerland Ltd, Building Technologies Group, International Headquarters, Gubelstrasse 22, CH-6301 Zug, Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies s Notes de la rédaction Sommaire - Content BACnet France Journal Forum BACnet à Amsterdam – BACnet Forum Amsterdam Diffusion Les collaborateurs, les membres, les représentants de la presse, et les partenaires de BACnet France peuvent recevoir gratuitement le BACnet France Journal bilingue (français/anglais) en le commandant en ligne à l’adresse suivante : mercurio@mardirect.de Le centre informatique de Leibniz choisit BACnet BACnet Automation for the Leibniz Computing Centre 10 L’intégration système au lieu du remplacement – Centre de soins Bernardus System Integration Instead of Replacement – Bernadus nursing centre 13 Rénovation économique à Den Helder – De Vijfsprong Economical Renovation in Den Helder – De Vijfsprong 1 Des bureaux modernes au « Latitude 20 » à Paris Modern offices in “Latitude 20” in Paris 1 Les forces de BACnet et KNX combinées dans un seul projet Strengths of BACnet and KNX – in St. Olav Hospital Trondheim 22 Réduction des coûts avec une qualité de service optimale – Infraserv Höchst Cost Reduction with Optimum Service Quality – Infraserv Höchst BACnet insight Editeur Association BACnet France Avec le soutien du BACnet Interest Group Europe Directoire du BIG-EU Volker Röhl, DeTelmmobilien (Président) Hans Werner Koch, Honeywell GmbH (Vice-président) Gijs de Koning, Regel Partner B.V. Roger Braun, Siemens Schweiz AG (Trésorier) 2 Une introduction à BACnet – An Introduction to BACnet 2 BACnet dans les environnements des technologies de l’information – BACnet in IT Environments 31 BACnet intègre la sécurité – BACnet Integrates Security 34 Les nouveaux objects BACnet pour des systemes de contrôles d’accès New BACnet Objects for Access Control Systems 3 Les objets et fonctions pour l’intégration des systèmes Objects and Functions for System Integration Produits – Products Rédaction MarDirect Marketing Direct GbR Bruno Kloubert Tel : + 49 231 42 78 67 31 e-mail : kloubert@mardirect.de 41 Tests de conformité à partir de 2007 – BACnet Test Framework 44 Le convertisseur de protocole BAC/IP pour la rénovation de Systèmes existants BACnet/IP Protocol Converter for the Renovation of Existing Systems 4 Contrôleur modulaire librement programmable Free Programmable Modular IO-Controller 4 Passerelles et visualisation – Gateways and Visualization L’organisation BACnet Publicité Mardirect Marketing Direct GbR Maguy de Mercurio Tel : + 49 231 42 78 67 31 e-mail : mercurio@mardirect.de Photos BACnet France, BIG-EU, MarDirect, et entreprises indiquées. BACnet© est une marque déposée de l’American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc. (ASHRAE). Editorial: Bon Vent à BACnet France – Editorial: All the best to BACnet France Solutions Le BACnet France Journal est le magazine en français sur l’automation du bâtiment basée sur la technologie BACnet. Les experts, les techniciens, les professionnels nous montrent le chemin à suivre en appliquant et en développant le Standard BACnet : cela va des tendances de l’automation du bâtiment aux dispositifs et aux projets d’application, de la qualification et de la formation aux tests et à la certification, du qui est qui dans la Communauté BACnet aux informations utiles et publications. Une attention toute particulière est portée aux activités et aux membres de l’Association BACnet France. Copyright / Tous droits réservés © BIG-EU 2007- Vous êtes encouragé à utiliser et publier des articles parus dans le BACnet France Journal en faisant bien sûr référence aux sources. Merci d’en faire parvenir une copie conforme à la rédaction, ou dans le cas d’une publication en ligne d’envoyer un URL par e-mail à : kloubert@mardirect.de 4 Les nouveaux membres – New Members 0 Sept raisons de devenir membre Seven Reasons for Becoming a Member 1 DeTelmmobilien devient membre du BIG-EU DeTeImmobilien Becomes BIG-EU Member 2 Comment BACnet répond aux dernières exigences technologiques et du marché How BACnet Meets the Latest Market and Technological Demands 4 Le calendrier BACnet – Calendar of Events BACnet France Journal iÊ>ÌÌÕ`iÊÓäÊDÊ*>ÀÃÊ£ÈÊ iÌÊÀÕÊ*>ÀÃÊxx Photo de couverture Cover picture L’immeuble « Latitude 20 » Modern offices in “Latitude 20” 01 04/07 Architecture BACnet /IP au Latitude 20 iÌÉ*Ê>ÀV ÌiVÌÕÀiÊÊ*>ÀÃÊÊ£È Une introduction à BACnet ÊÌÀ`ÕVÌÊÌÊ iÌÊÊÓx Toutes les éditions peuvent être téléchargées dans la section service du site www.big-eu.org. All issues can be downloaded from the service area of www.big-eu.org. Tests de conformité à partir de 2007 iÌÊ/iÃÌÊÀ>iÜÀÊÊ{£ Ê Sept raisons de devenir membre -iÛiÊ,i>ÃÃÊvÀÊiV}Ê>ÊiLiÀÊxä Association BACnet France BACnet France Journal 1 04/07 3 TA 7 em Syst JC DX/TC Don’t miss the connection! Priva Staefa AS1000/pronto BMS migration with BACnet IP Protocol Converter With the protocol converter, there’s no need to write off your current system. The protocol converter lengthens the lifespan of operationally sound DDC equipment and allows for a seamless connection with the BACnet communication protocol. BACnet immediately offers you various modern options, increased functionality and greater freedom of choice for the future. The benefits of BACnet? Interoperable system integration; compatibility across different brands, no specific hardware necessary and no licensing fees. Implemented in an Ethernet environment and remotely operated via the Internet. The result: affordable, easy to use, innovative building management systems. VisL&G Un ionik/ igy r Regel Partners B.V. Hogebrinkerweg 8 3871 KN Hoevelaken P.O. Box 86 3870 CB Hoevelaken T. +31 (0)33 254 48 48 F. +31 (0)33 254 48 44 info@regelpartners.nl www.regelpartners.nl For more information, please visit our website. Regel Partners makes it happen! System Integrators with Content ABB drives for HVAC applications: “Peace of mind - for me and my building” “The ABB HVAC drive does everything; it is remarkably easy to use and saves significant amounts of energy. My people have never been happier. The energy saving capability, for example, gives payback in less than two years. After that the savings generate profit straight to my bottom line. ABB will be here in 10 years time and beyond. That is the best guarantee ABB can give me.” Here’s why ABB’s HVAC drive really does make a difference - as standard: • One drive range for the entire building - 0.75 to 355 kW, 400 and 200 V, IP21 and IP54 • ABB’s patented swinging chokes - reducing harmonics by up to 25 per cent at partial loads • Real-time clock and calendar - providing true time and date stamps to drive events • Fault logger, capable of recording seven diagnostic values with true time and date - you know precisely what happened and when • Built-in EMC filter - eliminating the need for external filtering • Integrated B-ASC (BACnet Application Specific Controller) Peace of mind comes as part of the package. ABB Oy Drives PO Box 184 FI-00381, Helsinki, Finland Telephone +358 10 22 11 Telefax +358 10 222 3764 E-mail hvac@fi.abb.com www.abb.com/motors&drives Bon Vent à BACnet France All the best to BACnet France BACnet est un bus de communication standardisé (EN-ISO 16484-5/-6). Ce bus conforme à la norme NF, s’est imposé sur le marché français : après plusieurs années de travail, constructeurs et intégrateurs ont maintenant une offre BACnet. L’association Confort-Régulation ( ACR ), devenue depuis peu le Syndicat des Automatismes du Génie Climatique et de la Régulation pour l’Efficacité Energétique du Bâtiment, a décidé avec le soutien de ses adhérents intéressés de fonder BACnet France. En développement depuis 2006, BACnet France verra le jour au printemps 2007. Tous les acteurs économiques offrant des solutions basées sur BACnet sont chaleureusement invités à rejoindre l’Association dès à présent. Il en va de même pour les adhérents de l’ACR intéressés tels que Schneider-TAC, Sauter, Kieback&Peter, Trend, Honeywell, Johnson Controls, et également Siemens Building Technologies. Il s’agit d’une association professionnelle à but non lucratif. Elle est complémentaire de l’association « BIG-EU » dont les actions contribuent au développement du standard de communication européen pour le bâtiment « BACnet », à sa promotion internationale et à la garantie de sa qualité qui repose sur l’interopérabilité, la certification et la normalisation. L’activité de l’ « Association BACnet France » consiste, sur la France à : développer l’usage du standard « BACnet » dans les applications concernant les bâtiments à usage résidentiel, tertiaire et industriel. promouvoir les solutions produits et services d’applications et les produits OEM utilisant le standard « BACnet ». favoriser les échanges avec les filières du bâtiment et les professions concernées afin d’enrichir et d’optimiser les solutions destinées aux équipements techniques. adapter l’usage du standard aux spécificités culturelles et structurelles de la France ( organisation des filières, de la prescription, de l’environnement et des canaux de diffusion des produits et services, etc ). assurer la coordination avec « BIG-EU » dans les domaines de la stratégie et des actions notamment en matière de communication à destination du marché. BACnet is a standard communication bus (EN-ISO 16484-5/ -6). This bus complies with NF and occupies a strong position in the French market: after several years of work, constructors and integrators are now proposing BACnet. The ACR (Association for Comfort and Regulation) that changed a short time ago into “Syndicat des Automatismes du Génie Climatique et de la Régulation pour l’Efficacité Energétique du Bâtiment”, has decided to create BACnet France with the support of its members: BACnet France was conceived in 2006 and will go into action in spring 2007. All companies offering BACnet-based solutions as well as the members of the ACR such as Schneider TAC, Sauter, Kieback&Peter, Trend, Honeywell, Johnson Controls and also Siemens Building Technology are cordially invited to join the association. BACnet France is a non-profit making, professional association. BACnet France will complement the BIG-EU which actively contributes to the development of the European BACnet communication standard, its international promotion and to the guarantee of its quality in terms of interoperability, certification and normalization. The role of the BACnet France association in France consists in: Developing the use of the BACnet standard in applications concerning residential, functional and industrial buildings. Promoting products, solutions and applications services as well as OEM products using the BACnet standard. Stimulating the exchange of information and ideas between the different building industry sectors and all the building professions to enrich and optimize solutions for technical equipment. Adapting the use of the standard to the French culture and structure (organization of the sectors, planning and means of distribution and services, …) Ensuring coordination with the “BIG-EU” in the field of strategy and actions, particularly in marketing communication. Le Forum BACnet qui tiendra se en octobre prochain à Paris sera un signe fort pour le marché français. The BACnet Forum which will take place next October in Paris will be a strong sign for the French market Disséminer, promouvoir, prescrire, former, faire valoir la certification des produits BACnet sur le marché Français sont les missions principales de BACnet France. Distributing, boosting, planning, educating and highlighting the certification of BACnet products on the French market are the main missions of BACnet France. Nous souhaitons « Bon Vent » à BACnet France et espérons que tous les acteurs économiques en France disposant d’une offre BACnet rejoindront vite BACnet France ! All the best to BACnet France! We look forward to welcoming all the BACnet players in France to our BACnet France Association. Jean-Daniel Napar Président de l’ACR Association Confort-Régulation Paris BACnet France Journal 1 04/07 BACnet Interest Group Europe BACnet à Amsterdam – la fréquentation du Forum dépasse toutes les attentes BACnet is strong in Amsterdam – Forum exceeds expectations 130 utilisateurs BACnet à Amsterdam ; des évènements BACnet à Milan, Paris, Zurich Stockholm prévus en 2007 : le fabricant de standard indépendants de communication pour l’automation du bâtiment progresse à travers l’Europe. 130 users in Amsterdam ; BACnet events are planned for Milan, Paris and Zurich in 2007: The developer of the independent communication standard is on the move throughout Europe. La fréquentation du premier Forum BACnet aux PaysBas, organisé par le BACnet Interest Group Europe ( BIG-EU ) a dépassé toutes les attentes. Le 6 décembre dernier à Amsterdam 14 fournisseurs et utilisateurs ont présenté les avantages de la technologie BACnet. Des propriétaires de bâtiments ont souligné la conce ption efficace du système. Des fabricants, des pres cripteurs, et des assembleurs ont loué la « bonne coop ération entre les sociétés concurrentes ». La compagnie Regel Partners B.V., basée aux Pays-Bas et mem bre de BIG-EU a joué, quant à elle, un rôle important dans le succès du Forum. Volker Röhl, président du BIG-EU a insisté sur le nombre croissant des mem bres à travers l’Europe. Gijs de Koning, membre du conseil d’administration de BIG-EU, a mis l’accent sur l’importance grandissante de BACnet aux Pays-Bas à la lumière des changements qui interviennent sur le marché. Jan Kerdel, expert en automation du bâtiments à la TVVL ( Association Technique des Pays-Bas pour l’Installation dans les Bâtiments ), a démontré les avantages de la standardisation. De plus, une exposition qui accompagnait le Forum a présenté un aperçu de la dernière technologie BACnet. Tous les acteurs de la profession étaient représentés à cette exposition, avec ABB, Celsius, Delta Controls, Digicontrol, Johnson Controls, Honeywell, KNX, Kieback&Peter, Priva, Regel Partners, Saia-Bur gess, Sauter, Siemens, et Trane. Les avantages des solutions ouvertes Aucun protocole de communication ne remplit les attentes technologiques et économiques. Frank Schubert de l’entreprise de logiciels MBS, plaide donc en faveur des solutions éprouvées et ouvertes telles que les propose BACnet. Karl-Heinz Belser de la société Johnson Controls a parlé de la plani BACnet France Journal 1 04/07 fication et de la réalisation de projets BACnet. Le Professeur Peter Fischer, membre du Conseil Consultatif a expliqué comment les entreprises pouvaient faire certifier leurs dispositifs conformément à la norme ISO EN 16484-5 BACnet standard. Les projets de référence de BACnet Pays-Bas Un grand nombre de projets de référence montre comment BACnet est utilisé en pratique. Saia Burgess Controls et Daikin garantissent des conditions ambiantes agréables et une utilisation optimum de l’énergie. Regel Partners et Digicon trol Benelux compare le « natif » BACnet à des solutions passerelles. L’asso ciation KNX a décrit les applications BACnet-KNX. Celsius Benelux a placé BACnet dans le monde de l’automation de l’industrie et du bâtiment. Enfin, Priva a montré que BACnet est bien plus que de l’automation du bâtiment. Le potentiel de BACnet rassemble les concurrents et les rend plus forts. Voici le message à retenir, transmis par Sauter Building Control Pays-BAS et Kieback&Peter Pays-Bas. Siemens Pays-Bas a présenté des solutions intégrées d’automation du bâtiment BACnet comprenant des alarmes incendie et des systèmes d’alarme contre le vol. Le système d’intégration est une véritable force de BACnet. Johnson Controls a donné des conseils pratiques pour la gestion de projets d’intégration. Honeywell Building Solutions a présenté un projet pour lequel un client pouvait choisir une série de dispositifs venant de différents fabricants. ABB a démontré la possibilité d’intégrer des convertisseurs de fréquence. Trane a commenté un projet concernant le SWIFT Center de Zoeterwoude en Belgique, dans lequel a été intégré un système de réfrigération dans un système d’automation du bâtiment fourni par Johnson Controls. Après le Forum BACnet à Amsterdam la chose était entendue pour tout le monde: BACnet prend de l’expansion aux Pays-Bas aussi vite que dans tout le reste de l’Europe. Amsterdam est le centre de l’architecture, de l’art et du design en Europe, il n’y avait pas meilleur endroit pour le premier Forum BACnet au Pays-Bas. Amsterdam is a European centre of architecture, art and design – there is no better place for the first BACnet Forum in the Netherlands. The first BACnet Forum in the Netherlands, which was organized by the BACnet Interest Group Europe (BIG-EU), exceeded all expectations. 14 suppliers and users presented the advantages of the BACnet technology on 6 December 2006 in Amsterdam. Building owners emphasised the efficient design of the systems. Manufacturers, specifiers and system integrators praised the “good cooperation between competing firms”. The Dutch based company and BIG-EU member, Regel Partners B.V., played an important role in ensuring the success of the Forum. Volker Röhl, President of the BIG-EU, pointed out the growing number of members across the whole of Europe. Gijs de Koning, member of the BIG-EU board, stressed the growing importance of BACnet in the Netherlands in the light of changes taking place in the market. Jan Kerdel, building automation expert at the “Nederlandse Technische Vereiniging Voor Installaties in Gebouwen (TVVL)“, emphasised the benefits of standardisation. In addition, an accompanying exhibition at the Forum presented an insight into the latest BACnet technology. The exhibition was truly multi-vendor with ABB, Celsius, Delta Controls, Digicontrol, Johnson Controls, Honeywell, KNX, Kieback&Peter, Priva, Regel Partners, Saia-Burgess, Sauter, Siemens and TRANE ta king part. The advantages of open solutions No communication protocol fulfils all technological and economic wishes. Frank Schubert from the software house, MBS, therefore appealed for proven, open solutions such as BACnet. Karl-Heinz Belser from Johnson Controls spoke about specifying, tendering and implementing BACnet projects; and Professor Peter Fischer, member of the BIG-EU advisory board described how companies can certify devices to prove their conformity to the ISO EN 16484-5 BACnet standard. Dutch BACnet reference projects A large number of reference projects showed how BACnet is being used in practice. SaiaBurgess Controls and Daikin have ensured pleasant ambi- ent conditions optimal use of energy. Regel Partners and Digicontrol Benelux compared “native” BACnet with gateway solutions. The KNX association described the BACnet-KNX mapping. Celsius Benelux placed BACnet in the world of building and industrial automation. That BACnet is more than just building automation was shown by Priva. BACnet’s potential brings competitors together and makes them stronger. This was the message of Sauter Building Control Netherlands and Kieback&Peter Netherlands. Siemens Nether lands demonstrated integrated building automation solutions using BACnet that included fire alarm and burglar alarm systems. System integration is a stated strength of BACnet. Johnson Controls gave practical tips for managing integration pro jects. Honeywell Building Solutions presented a project where the customer was able to choose best of breed de vices from different manufacturers. The possibility of integrating frequency converters was demonstrated by ABB. Trane described a project at the SWIFT Center in Zoeterwoude where they integrated a refrigeration system into a building automation system supplied by Johnson Controls. After the BACnet Forum in Amsterdam it was clear that BACnet is growing just as fast in the Netherlands as it is throughout the rest of Europe. Dates du BACnet Forum BACnet on the move – roadmap of the BACnet Forum BACnet Forum Amsterdam December 12, 2006 BACnet Forum Milano February 12, 2007 BACnet Forum Zurich June 12, 2007 BACnet Forum Paris Octobre 2007 (voir p 55) BACnet Forum Stockholm in preparation BACnet Forum London in preparation www.bacnetforum.org BACnet France Journal 1 04/07 Solutions Le Centre Informatique de Leibniz a choisi BACnet BACnet Automation for the Leibniz Computing Centre Le 21 juillet dernier, le Centre Informatique de Leibniz ( LRZ ) de l’Académie des Sciences Bavaroise a lancé un « super ordinateur » dans son centre de recherche de Garching près de Munich. Associé à deux autres « super ordinateurs » situés à Jülich et Stuttgart, il est fait pour le plus grand réseau d’ordinateur européen. En phase 1, le nouveau super ordinateur SGI® Altrix ® 4700 de Silicon Graphics a été équipé du processeur 4.096 Intel® Itanium®2 et d’une mémoire principale de 17 Terabyte. Il exige d’avoir à disposition une surface au sol de 25m². Il nécessite également 2MW pour fonctionner et un système d’air conditionné parallèle à l’ordinateur. Ce nouveau super ordinateur est utilisé pour la simulation de systèmes complexes et de processus dans les domaines de la physique, la recherche sur métaux, la dynamique des flux, l’astrophysique, la chimie ou bien encore la géographie et les sciences de la vie. Le coût de construction des trois sections de bâtiment l’accueillant ( une zone pour l’ordinateur, un institut et un auditorium avec plus 5.600 m² ) est supérieur à 45 millions d’euros. Sur cela, 38 millions d’euros sont destinés à l’ordinateur lui même. Les coûts sont supportés par l’Etat de Bavière et la République Fédérale d’Allemagne. Le Centre Informatique de Leibniz est situé au sud du campus de l’Université Technique de Munich-Garching. réfrigérateurs sont intégrés dans le concept d’automation via l’inter face LonTalk® Feldbus construite dans l’Excel Web d’Honeywell. De la gestion de la température pour les zones où se trouve l’ordinateur. De la gestion des protections incendie avec la fonction de rejet de fumée et de gaz. Les passerelles UG1500 de MBS GmbH facilitent la conversion en BACnet/IP du système de bus d’extincteur de DSSteuerungstechnik. © Kai Hamann, produced by gsiCom Avec un solution native BACnet Honeywell réalise l’automatisation complexe du nouveau bâtiment du centre de recherche informatique de Leibnitz près de Munich. With a native BACnet solution Honeywell realised the complex automation in the new building sections of the Leibniz Computing Centre near Munich. Le propriétaire, représenté par l’autorité de la construction de l’Université Technique de Munich, a fait appel au standard ouvert BACnet pour l’automation du bâtiment des 3 sections du LRZ. Concept complexe d’automation Ce concept complexe d’auto mation a été proposé et réalisé par Honeywell Building Solutions et comprend : 22 systèmes DDC Excel Web® BACnet® d’Honeywell ( environ 3500 points de données ) Les systèmes DDC sont responsables : De la régulation, de l’op timisation et de la gestion de la production/ distribution de la chaleur aussi bien que du contrôle de la température au cœur du bâtiment De la régulation, l’opti misation et la gestion de la production de froid et de la distribution par 5 systèmes de refroi dissement Carrier avec une interface LON®. Les BACnet France Journal 1 04/07 Nouveau super ordinateur au LRZ. New Supercomputer at the LRZ. De l’intégration de divers messages d’équipement. Du contrôle et de la gestion des 8 machines compactes à air conditionné avec les systèmes intégrés DDC BACnet PXC52/ PXC12 de Siemens ( 57 points de données pour chaque machine ). Du contrôle et de la surveillance des 34 systèmes de re-circulation de froid fournis par Econdition GmbH. Chaque système est natif BACnet / IP compatible via une passerelle Modbus 4000 MODBAC01 de marque Plüth Regel systeme GmbH. La plate-forme d’intégration ouverte de dernière génération d’Honeywell Enterprise Buildings Integrator™ est utilisée au niveau gestion. Il permet l’intégration parfaite de produits issus de fournisseurs multiples car il intègre la fonctionnalité BACnet Operator Workstation. Au total 6500 points de données BACnet sont supervisés par le système de gestion mis en place au LZR qui aide le personnel technique à intervenir en toute sécurité sur les équipements rencontrant des problèmes. On July 21, 2006 the Leibniz Computing Centre (LRZ) of the Bavarian Academy of Sciences started up a new supercomputer at its research centre in Garching near Munich. Together with two other supercomputers loca ted in Jülich and Stuttgart, this makes for the largest European computer network. In phase one, the new supercomputer SGI® Altrix® 4700 from Silicon Graphics has been equipped with 4,096 Intel® Itanium®2 pro cessors and a main memory of 17 Terabytes. It requires a floor space of 25 metres in both directions. Approximately 2 MW are required to operate and air condition the parallel computer system. © Schürmann, TU München Three new building sections in the LRZ The new supercomputer is used for the simulation of complex systems and pro cesses in physics, material research, flow dynamics, astrophysics and chemistry as well as in the geosciences and life sciences. The construction cost for the three building sections (computer room, institute and the audi- Entrée principale du LRZ. Main Entrance of the LRZ. © Ernst A. Graf, TU München Solutions torium with an effective total space of 5.600 sqm) amount to 45 million Euros. On top of this comes an investment in the computer of 38 million Euros. Costs are split between the Free State of Bavaria and the Federal Republic of Germany. The LRZ is located at the south of the Technical University Munich Garching campus. The owner, represented by the construction authority of the Technical University of Munich, asked for the open BACnet standard when it came to building automation of the three LRZ sections. Complex automation concept The extensive automation concept was realised by Honeywell Building Solutions and consists of 22 Honeywell BACnet® DDC systems Excel Web® (approx. 3,500 data points). The DDC systems are responsible for example for the regulation, optimisation and monitoring of heat production and distribution as well as tem- Centre informatique de Leibniz vu du ciel. Leibniz-Computing Centre, aerial photo. perature control of the building´s concrete core; regulation, optimisation and monitoring of the cooling and distribution by five chiller plants from Carrier with a LON® interface. The chillers are integrated into the automation concept via the LonTalk® field bus builtinto the Honeywell Excel Web; temperature monitoring of the computer rooms, integration of various plant messages; controlling and monitoring of eight compact air conditioning machines with integrated BACnet DDC systems Siemens PXC52/ PXC12 (57 data points for each machine); controlling and monitoring of 34 recirculation cooler systems delivered by Econdition GmbH. Each system is made BACnet/IP compatible through a PR-4000 MODBAC01 ModbusGateway from Plüth Regelsysteme GmbH; monitoring of the fire dampers with smoke exhaust function as well as exhausting of the fire extinguishing gas. UG1500 gateways from MBS GmbH facilitate conversion of the damper bus system from DS-Steuerungstechnik to BACnet/IP. Safe Plant Operation The state of the art open integration platform Honeywell Enterprise Buildings Integrator™ (EBI) is used on the management layer. It enables optimal multivendor integration tasks because it includes BACnet Operator Workstation functionality. In total 6,500 BACnet data points are supervised by the manage ment system at the LZR and support the technical staff in safely operating the critical plants. Christian Müller Manager Marketing and Communication Honeywell GmbH Honeywell Building Solutions hbs.info@honeywell.com www.honeywell.de/hbs BACnet France Journal 1 04/07 Solutions L’intégration système au lieu du remplacement System Integration Instead of Replacement Pour l’extension du système de Gestion Technique du Bâtiment de l’hospice Hollandais Bernadus, Regel Partners utilise le convertisseur de protocole BACnet/IP afin d’intégrer les composants déjà existants. For the expansion of the building management system of the Dutch Bernardus nursing centre, Regel Partners uses BACnet/IP protocol converters to integrate already existing components. Le centre Bernardus de Sassenheim, aux Pays-Bas est à la fois un centre de soins et hospice. La centre de soins accueille 142 résidents dans 3 départements séparés, tandis que le foyer pour personnes âgées en accueille 55 autres. Depuis la mise en place en 1998 du système de gestion du bâtiment Siemens TS1500, le centre Bernardus a procédé à des extensions régulières, toutes accompagnées par l’installation de nouvelles stations secondaires et de panneaux de contrôle. Les développements se sont encore poursuivis en 2006 et comprennent: L’optimisation de l’approvi sionnement en eau chaude, en utilisant 4 chaudières. Ce sont près de 20 mesures de température prises à travers tout le complexe à titre préventif contre la maladie du légionnaire. L’extension de 2 unités de traitement d’air via l’installation de refroidis sement intégré dans le plafond. L’intégration du contrôle de l’éclairage dans le sys tème de GTB. L e journal des événements et alarmes assignés à différentes installations auto nomes et des mesures de températures additionnel les, tout ceci dans le but de rendre le système de gestion plus ouvert. Les challenges techniques L’extension du système actu el a laissé les problèmes sui vants derrière elle : L es stations secondaires existantes du type AS1000 ne seront plus disponibles en 2007. L e système TS1500 qui fonctionne sous MS-DOS ne connait plus d’amélio rations. La mise en application de fonctions de gestion modernes en ce qui concerne la maintenance optimale des installations et le déploiement proportionné de fonds est cependant nécessaire. Une solution de communication moderne pour la connexion des différents systèmes au sein des bâtiments est fortement demandée pour les employés de Valent RDB. 10 BACnet France Journal 1 04/07 Le remplacement complet du système de gestion du bâtiment, la solution qui paraissait la plus évidente, aurait coûté environ 90 000 Euro, incluant les extensions nécessaires. De plus, la dépréciation du système existant aurait également été synonyme de perte, alors qu’il n’est qu’à la moitié de sa durée de vie « technologique ». L’application du convertisseur de protocole Pour atteindre les objectifs voulus à un niveau d’inves tissement acceptable, le choix s’est porté sur l’utilisation des convertisseurs de protocole programmables BACnet IP. Le convertisseur de protocole, directement connecté au port com de la DDC, System Integrators with Content permet de continuer à utili‑ ser les composants existants AS1000 et de les intégrer dans un environnement plus moderne. Tous les points d’information sont convertis en objets BACnet et chaque panneau de contrôle est équipé d’une connexion au réseau Ethernet existant, qui peut être connecté à un utilisateur Web. La communication des AS1000 via Ethernet TCP/IP offre un niveau élevé de flexibilité. L’infrastructure existante peut être utilisée pour une extension future ou un remplacement ( partiel ) des stations secondaires. Un poste de travail BACnet ( Operator Work Station / B-OWS ) a été sélectionné pour l’exploitation et la ges- Solutions Centre de soins Bernardus à Sassenheim, Pays-Bas. The Bernardus Nursing Centre in Sassenheim, Netherlands. tion. Ce système peut être actionné localement et via Internet, incluant également le journal des alarmes et événements requis. Puisque l’application du convertisseur de protocole a eu pour conséquence de conser ver les stations secondaires existantes, le seul achat que l’extension ait demandé a consisté en l’acquisition de nouveaux produits BACnet. Le résultat : un investissement d’environ 45% infér ieur au coût d’un remplacement du système et bien sûr les gains réalisés, puisque sa dépréciation s’est alors arrêtée. Pour toutes extensions futures et remplacements, les bénéfices tirés de BACnet et de son interopérabilité continuent à être valables. The Bernardus in Sassen heim, Netherlands is a soma tic nursing home and assisted living centre. The nursing home houses 142 residents, in three separate departments. The assisted living centre houses another 55 resi dents. Since the realisation of the Siemens TS1500 building management system in 1998, the Bernardus has experienced regular expansions, all of which were accompanied by the installation of new substations and control panels. The developments are ongoing in 2006 and include: The optimisation of the warm water supply, using four boilers. Around 20 temperature measurements taken throughout the complex as part of an effort prevent in legionnaire’s disease. The expansion of 2 air handling units through the installation of top cooling. Integrating the lighting control into the building management system. Alarm reports for various autonomous installations and additional temperature measurements, both aimed at a more open management system. ment system, the most obvious solution, would incur a price tag of around 90 thousand Euros, inclu ding the necessary expansions. On top of this, the early depreciation of the existing system would pose a significant loss, with only half of the technological life-span having elapsed. Technical Challenges The expansion of the current system left the following problems unaddressed: The existing substations of the AS1000 type will no longer be available in 2007. The TS1500 system runs under MS-DOS, a system that no longer undergoes improvements. Implementation of modern management functions with respect to optimum maintenance of the installations and adequate deployment of funds is however necessary. A modern communication solution for connecting the various building systems is desired for the staff of the Valent RDB organisation. The protocol converter, directly connected to the com port of the DDC equipment, allows for the continued use of the existing AS1000 components and places them in a modern environment. All information points are converted to BACnet objects and every control panel is equipped with a connection to the existing Ethernet network that can, in turn, be connected to a web user. The communication of AS1000 via Ethernet TCP/IP allows for a high degree of flexibi lity. For future expansion or (partial) replacement of substations the existing infrastructure can be used. The complete replacement of the building manage- Application of Protocol Converter In order to achieve the desired objectives at an acceptable investment level, the choice was made to use programmable BACnet/IP protocol converters. For operation and management, a BACnet Operator Work Station (B-OWS) has been selected. This system can be operated locally and via the Internet, including the reporting of necessary alarms and events. Since the application of the protocol converter resulted in the existing substations being maintained, the only purchase required for the expansion consisted of the new BACnet products. This resulted in an investment that came in at around 45% lower than the complete replacement of the system, while the costs of early depreciation were also saved. For any future expansions or replacements, the benefits of the interoperable BACnet standard will remain in effect. Gijs de Koning Regel Partners B.V. g.dekoning@regelpartners.nl www.regelpartners.nl BACnet France Journal 1 04/07 11 DIGICONTROL ems 4 Including fascination. DIGICONTROL ems 4 – economic modular system ist ein netzwerkbasiertes, interdisziplinäres Automationssystem für universelle Aufgaben in allen Bereichen der Gebäude- und Industrieautomation. Die offene Kommunikation über alle Übertragungswege, der konsequente Einsatz eingeführter Standards, die Nutzung vorhandener IT-Infrastrukturen, die Integration unterschiedlichster Gewerke und Systeme sowie das durchdachte, modulare Gesamtkonzept mit dezentraler Aufgabenverteilung durch feinmodulare, intelligente Baugruppen prädestinieren das Automationssystem für sämtliche Anforderungen der Zukunft. Zur neutralen Kopplung an beliebige Automations- und Managementsysteme ist die BACnet-Konformität ein integraler Bestandteil der Baureihe DIGICONTROL ems 4. DIGICONTROL ems 4 – economic modular system is a network-based, interdisciplinary, automation system for universal tasks in all areas of building and industrial automation for systems of all sizes. The open communication via all transfer methods, the consistent use of introduced standards, the use of existing infrastructure, the integration of various areas and systems as well as the sophisticated, modular overall concept with decentralised distribution of tasks via fine modular intelligent assemblies mean that the automation system is perfectly suited for all future requirements. BACnet compliance is an integral component of the DIGICONTROL ems 4 series for neutral connection to any automation and management systems. OFFEN OPEN REDUNDANT REDUNDANT INTELLIGENT INTELLIGENT DURCHGÄNGIG UNIVERSAL nativer BACnet Controller CAN-LIN-Bus I/O-Module mit integrierter CPU einfache Projektierung mittels WEBPROJECT und WEBCADpro FLEXIBEL feinmodularer Aufbau Ethernet/IP, USB, RS485, RS232 M-BUS, KNX, LCN, DALI, LON embedded WEBSERVER SD Memory Card Native BACnet controller CAN-LIN-bus I/O-modules with integrated CPU Simple project planning via WEBPROJECT and WEBCADpro FLEXIBLE Fine modular structure Ethernet/IP, USB, RS485, RS232 M-BUS, KNX, LCN, DALI, LON Embedded WEBSERVER SD memory card Lassen auch Sie sich begeistern. Infos unter www.gfr.de Let also become enthusiastic. More informations you will get here: www.gfr.de GFR –– Gesellschaft für Regelungstechnik und Energieeinsparung m.b.H. Kapellenweg 42 · D-33415 Verl Telefon +49 ’ 52 46’9 62-0 Telefax +49 ’ 52 46’9 62-199 Solutions Rénovation économique à Den Helder Economical Renovation in Den Helder Saia-Burgess Controls et Daikin réalisent un climat ambiant confortable et des économies d’énergie au siège de la société immobilière « Woningstichting Den Helder ». Saia-Burgess Controls and Daikin realized an agreeable climate with maximum energy efficiency in the head office of the house-building society “Woningstichting Den Helder”. La société immobilière « Wo ningstichting Den Helder » a complètement rénové son bâtiment monumental « de Vijfsprong » situé à Den Helder aux Pays-Bas et l’uti lise désormais comme son propre siège. De la conception à la réalisation de cette réhabilitation,l’économie d’énergie était au cœur de toutes les préoccupations de cette société immobilière, comme le précise Peter van Doorn, conseiller technique chez Woningstichting Den Helder : « Il est évident que le nouveau siège devait être peu consommateur d’énergie et offrir un excellent climat de travail à tous les employés ». Un contrôle vaste du climat ambiant Ce bâtiment gigantesque appelé « de Vijfsprong », construit en 1923, est situé au cœur de la ville de Den Helder, base domiciliaire de la Marine Royale Hollan daise. Fin 2004, la société immobilière a acheté ce bâtiment ainsi que ceux adjacents en vue d’agrandir ses locaux. En 2005, le bâtiment s’est agrandi, tout en respectant son style traditionnel, tandis que la partie la plus ancienne a été rénové pour répondre aux normes actuelles. Désormais, le « Woningstichting Den Helder » abrite l’équipe d’ingénierie de près de 50 personnes qui travaillent dans ce nouveau bâtiment. Un des soucis de la rénovation était le manque d’espace pour une deuxième centrale de chauffage. C’est pourquoi on a installé le système climatique Daikin VRVII, grâce à ses valeurs d’isolation appropriées à refroidir, chauffer et climatiser intégralement le nouvel immeuble. Dans le bâtiment ancien on utilise le système de chauffage conventionnel de Remeha pour couvrir les besoins en chaleur. Un climat ambiant Le protocole BACnet a permis de fusionner le système de chauffage central existant de la société Remeha avec le nouveau de marque Daikin, pour un contrôle sans faille de l’ensemble du site. Les dispositifs Daikin communiquent désormais via la passerelle D-BACS de Daikin, avec les produits Saia-Burgess Controls tels que le Saia©PCD3 B-BC et le Saia Burgess Controls SCADA package Visi+. Avec l’installation Daikin VRVII, le climat intérieur peut être régulé indépendamment dans les 46 pièces. Avec 6 pompes à chaleur, qui sont positionnées sur le toit du bâtiment, il est tout à fait possible de chauffer ou de refroidir avec un système et sans technique locale additionnelle. Tous les points de données exigés sont mappés par la passerelle D-BACS en tant qu’objets BACnet individuels. En utilisant la fonctionnalité client à haut rendement du Saia©PCD3 B-BC, cette information est intégrée dans la stratégie commune de commande. Les chaudières murales à modu lation fournies par Remeha de type Quinta, toutes les pompes de circulation, les Vue du projet complet « de Vijfsprong ». Designed view of the complete project “de Vijfsprong”. BACnet France Journal 1 04/07 13 Others use the term „Native BACnet®“... we call it open, adaptable and reliable ! r e ll o tr n o C y g rt in e d p ion il ro t P isa ) u C tB te n -B ne r i ro (B C W c n / A g y d B a S lin re e o R me du g st Ti h e i n / R e c d S en up Tr ck a B c. t e We b- Pa ne lC E S Au a i a ® tom PC ati D3 on B S t a AC n tio et ® n P ro fi We b u s F T P M- E IB o /K M Bu s Pa ne le XP I T L H A x D e s n u n b o d T P E n ce s n u a -B o P . M etc b- Saia-Burgess Controls AG Bahnhofstrasse 18 | CH-3280 Murten | Switzerland T +41 26 672 71 11 | F +41 26 672 74 99 www.start-controls.com | pcd@saia-burgess.com Solutions Le siège rénové “de Vijfsprong” à Den Helder. The renovated head office “de Vijfsprong” in Den Helder. soupapes et obturateurs sont contrôlés via les modules Entrée/Sortie à l’intérieur du contrôleur PCD3. Grâce au diagnostic à distance réali sable par l’intermédiaire d’un modem connecté au PCD3, l’équipe de maintenance peut changer les paramètres à tout moment. Un retour de chaleur de 95% Grâce à la flexibilité de la solution DDC de Saia-Burgess Controls et aux nombreuses années d’expérience de Zwirs Regeltechniek & Advisering b.v., l’intégration des différents systèmes s’est faite sans aucun problème. Le Directeur Luc Zwirs s’en réjouit en précisant que le temps passé en phase d’ingénierie et de mise en service a consi dérablement été réduit grâce à l’utilisation de la norme BACnet. L’application est en place depuis 6 mois maintenant à la plus grande satisfaction du propriétaire, des utilisateurs et du personnel technique. Pendant ce temps, l’efficacité du retour de chaleur a augmenté de 95%. The house building society “Woningstichting Den Hel der” has completely renovated the monumental building “de Vijfsprong” in Den Helder, The Netherlands is now using it as their own head quarters. Starting from the first concept up to the realization of the re- construction, energy saving was been the key issue to the house building society. Peter van Doorn, technical advisor of Woningstichting Den Helder, constitutes: ”It was self-evident that the new office should have low energy consumption with an excellent climate for all employees.“ Comprehensive Climate Control The monumental building “de Vijfsprong”, built in 1923, is situated in the centre of Den Helder, the hometown of the Royal Dutch Navy. The house building society bought “de Vijfsprong” in 2004 together with the adjacent buildings to enlarge their premise. In 2005, the building was extended in the same traditional style, while the old part was renovated to meet today’s standards. Today, the “Woningstichting Den Helder” engineering staff of 50 people work in the new building. One of the main concerns during the rebuilding was the lack of space for a second heating system in the old building. Therefore, a new heating and air conditio‑ ning concept was needed. The climate control unit from Daikin VRVII adequately supplies the well isolated new extension with heating and air conditioning. The older part of the building still uses the central heating system from Remeha. Suitable Climate for Each Room The BACnet protocol enables the existing central heating from Remeha to be integrated with and the new one Daikin for a smooth central control of the whole plant. The Daikin devices now communicate through the Daikin Gateway D-BACS with the Saia©PCD3 B-BC and the Saia-Burgess Controls SCADA package Visi+. With the Daikin VRVII installation, the climate can be regulated independently in all 46 rooms. With the 6 heating pumps, which are mounted on the roof of the building, it is possible to heat and cool with one system and without an additional technical room. connected to the PCD3, the service staff is able to change every setting at any time. Heat Return of 95 Percent Thanks to the flexibility of the DDC solution from Saia -Burgess Controls and many years’ experience of Zwirs Regeltechniek & Advisering B.V., the integration of the different systems has been realized without any problems. Director Luc Zwirs confirmed that the time spent for engineering and commissioning decreased considerably because of the use of the BACnet-standard. The application has been running for half a year now, to the full satisfaction of the owner, users and service staff. Armoire de distribution parfaitement rangée avec le Saia© PCD3 et la passerelle BACnet Daikin D-BACS. Neat and clean looking cabinet with the Saia©PCD3 and the Daikin BACnet Gateway D-BACS. All required data points are mapped on the Gateway D-BACS as individual BACnet objects. Using the high performance client functionality of the Saia©PCD3 B-BC, this information is integrated in the common control strategy. Both Remeha modulating wall-hung boilers of the type Quinta, all circulation pumps, valves and shutters are controlled with the through I/O modules within the PCD3 controller. With remote diagnostics by means of a modem In the meantime, the efficiency of the heat return has been increased to 95%. Dr. Simon Ginsburg Product Manager Saia-Burgess Controls AG simon.ginsburg@saiaburgess.com www.start-controls.com Martin van Cappellen Technical and commercial advisor Saia-Burgess Benelux B.V. martin.vancappellen@saiaburgess.com www.start-controls.com BACnet France Journal 1 04/07 15 Solutions Des bureaux modernes au « Latitude 20 » Modern offices in “Latitude 20” in Paris Détails du projet : Lieu : Bagneux Surface : 12000 m² Nombre d’étages : 4 Entreprise Générale : Bouygues Construction Privée Investisseur : STAM Europe Intervenants : Kieback&Peter, Trane Project Details: Location: Bagneux, France Surface: 12,000 m² Number of floors: 4 Principal: Bouygues Construction Privée Investor: STAM Europe Subcontractors: Kieback&Peter, Trane C’est dans le département des Hauts de Seine ( 92 ) que nous nous rendons pour faire référence à un projet immobilier très récent puis que réceptionné avec succès par le client en juin 2006. L’immeuble LATITUDE 20 est un bâtiment neuf de 12000m² de surface ( divisible ). Ses grandes surfaces extérieures vitrées s’élèvent sur 4 étages offrant une luminosité idéale aux résidants des bureaux intérieurs. Kieback&Peter France a suivi ce projet devenu réalité du début à la fin pour garantir le respect du cahier des charges et des exigences clients en matière de GTB. Fournisseur reconnu de GTB, Kieback&Peter a donc assuré la conception et la fourniture de ses systèmes au regard de ces 2 éléments. D’un point de vue technique, l’immeuble Latitude 20 fait la part belle à BACnet, protocole incontournable du secteur du bâtiment. La volonté du client étant d’avoir au final un bâtiment indépendant des systèmes propriétaires et évolutifs. BACnet présente cet avantage. Côté BACnet, l’immeuble contient un superviseur GLT Neutrino Kieback&Peter en BACnet natif. Ce superviseur assure la gestion de l’automation. Il permet au client de contrôler/comman der toutes les installations techniques. 16 BACnet France Journal 1 04/07 Solutions Au « Latitude 20 » les exigences de l’investisseur sont réalisées de manière optimale avec BACnet. “In Latitude 20” the investor’s requirements could be optimally realised with BACnet. Raccordés au superviseur, deux systèmes d’automate DDC4000 en BACnet natif qui assurent la régulation et le contrôle permettent au technicien de mesurer, réguler, piloter, optimiser et superviser les installations techniques. Ces automates communiquent via Ethernet ( TCP/IP, BACnet ). L’avantage de la communication ouverte, de la gestion et de la maintenance des installations, tels sont les plus offerts par BACnet et les produits Kieback&Peter sur le site LATITUDE 20. Deux groupes froid natif BACnet de chez TRANE sont repris sur le superviseur, sans oublier les 17 compteurs d’énergie qui sont raccordés via BACnet au superviseur Neutrino. Ainsi, les ventilo-convecteurs, l’éclairage, les groupes froid et automates tous unis sur le réseau Ethernet, interagissent et fonctionnent via le protocole BACnet. Cette réalisation démontre qu’une architecture BACnet / IP peut fédérer plusieurs lots techniques sans aucun problème d’intégration ou bien encore de commande des installations. Le protocole BACnet, ouvert, normé a pleinement répondu aux exigences du client final. Il permet au client de dispo ser d’un bâtiment sous protocole spécifique au bâtiment, ouvert, normé, lui assurant flexibilité, évolutivité et pérennité. It is in the department Haut de Seine (92) that we go to refer to a very recent project delivered successfully to the customer in June 2006. The LATITUDE 20 building is a new construction of 12,000 m² surface area (divisible). Its great glazed exter nal facade, four floors high, offers ideal day lighting to the residents of the offices. Kieback&Peter France followed this project from the inception to delivery in order to guarantee the respect of the customer’s needs and schedule of requirements regarding the building management system (BMS). A recognized supplier of BMS, Kieback&Peter ensured the design and the delivery of the system, taking these 2 elements into consideration. From a technical point of view the Latitude 20 building is a real BACnet showcase of the inevitable protocol in building automation. The building’s system is completely open and ready for expansion as part of the customer’s requirements, be nefits which were perfectly met by BACnet. On the BACnet side, the building includes a native BACnet Neutrino BMS automation station from Kieback&Peter. This automation station ensures automation management, allowing the customer to control and command all technical installations. Two DDC4000 automation systems with native BACnet are connected to the supervisor, ensuring regulation and control and thus enabling the technician to monitor, regulate, control, optimize and supervise the technical installations. Those devices communicate via Ethernet (TCP/IP, BACnet). The advantage of open communication, management and maintenance of the easy to handle installations is provided at Latitude from BACnet and the Kieback&Peter products. Two native BACnet refrige ration groups from TRANE are integrated into the automation station as well as 17 energy meters connected to the Neutrino automation station via BACnet. Thus the air converters, lighting, cooling systems and automation devices, all integrated into the Ethernet, interact and operate via the BACnet protocol. This realization proves that a BACnet / IP architecture can unite numerous technical units without any system integration or control problems. The open and standardized BACnet protocol, has perfectly met the requirements of the customer, who now possesses a building with a specific BMS protocol, and providing him with flexibility, expansion possibilities and continuity. Mme Tina Mühe Kieback&Peter SA muhe@kieback-peter.fr www.kieback-peter.de/19/ BACnet France Journal 1 04/07 17 ManageMent takeS Care OF bIg buSIneSS. SMall taSkS alMOSt take Care OF theMSelveS. AXI.COS ® – controls everything. Facility Management is not only responsible for the small tasks of everyday life. Even complex processes can be optimized through intelligent and efficient building automation systems. Such as analyses of access reports in order to define cleaning and service schedules or room occupancy management. AXI.COS® supports you in these tasks, as an integrated Control Operating System (COS), which generates, administrates and evaluates data – and which controls diverse processes. In order to manage buildings more intelligently. In order to optimize your processes. In order to save energy. In a nutshell: More efficiency, lower cost. Axima GmbH Duerener Strasse 403 - 405 · 50858 Cologne Fon: +49.(0)2 21.4 69 05 - 0 www.axima.de · info@axima.de Axima GmbH is a SUEZ Energy Services Germany Company Solutions Les forces de BACnet et KNX combinées dans un projet Strengths of BACnet and KNX Combined in one Project L’hôpital universitaire St.Olav de Trondheim sera l’un des centres médicaux les plus modernes d´Europe d’ici 2015. Les forces des standards internationaux BACnet ( EN ISO 16484 ) et KNX ( ISO/IEC 14543 ) vont être combinées au sein d’un même système d’automation du bâtiment. The St. Olav University Hospital in Trondheim, Norway will be one of Europe’s most modern health centers by 2015. The strengths of the worldwide standards, BACnet (EN ISO 16484) and KNX (ISO/IEC 14543), are being combined in one building automation system. L’hôpital St. Olav est à la fois une entreprise et un hôpital universitaire situé au centre de la Norvège dans région comptant 630 000 habitants. Le nouveau cen tre de soins traitera les patients et assurera également la recherche et la formation. Les premiers bâtiments ont ouvert cou rant 2006 et l’intégralité du centre sera exploitable dès 2015. L’hôpital s’étendra sur 210 100 m². Siemens a gagné le contrat de réaliser l’automation du bâtiment au sein du nou- veau centre. Le standard mondial KNX sera employé pour le contrôle de l’éclairage, la protection solaire et le contrôle de la température dans plus de 2700 chambres. DESIGO INSIGHT sera utilisé en tant que système de gestion et les postes d’automation DESIGO PX seront utilisés afin d’intégrer les systèmes KNX. DESIGO permet à l’équipe technique d’accéder à distance aux systèmes via Internet. Les stations d’automation DESIGO PX sont physiquement connectés au système de gestion via ETHERNET en utilisant le standard international BACnet sur IP. L’intégration de l’auto mation de zone KNX dans le système d’automation du bâtiment BACnet En tant que norme internationale pour les systèmes d’automation de la maison et du bâtiment, KNX est mis en application en tant que standard au niveau ter- rain dans de grands projets et ce depuis plus de 15 ans. La certification et l’inter opérabilité garanties permettent le développement avec des systèmes multi fournisseurs spécifiques au projet, proposant un choix large parmi les quelques 7000 groupes de produits. L’outil indépendant d’inté gration ( ETS ), indépen damment des fabricants et de produit, rend ainsi la configuration facile à réaliser. Le standard BACnet continue de s’imposer dans de nombreux projets comme le protocole idéal pour les fonctions d’automation et de gestion. En combinant ces deux standards dans un seul et unique projet, cela permet l’intégration d’un La topologie des deux protocoles ouverts. The topology of the two open protocols. BACnet France Journal 1 04/07 19 ® • ISO/IEC 14543 • CENELEC EN 50090 • CEN EN 13321 La NORME mondiale pour la gestion technique de la maison et du bâtiment ABB Sace S.p.A • ABB Schweiz Normelec (Levy Fils AG) • ABB Stotz-Kontakt GmbH • AGFEO GmbH & Co. KG • Albrecht Jung GmbH & Co. KG • Altenburger Electronic GmbH • Amacher AG • arcus-eds GmbH • Ardan Control-Tech Ltd • BBT Thermotechnik GmbH • BeckerAntriebe GmbH • Berg Energie-Kontroll-Systeme GmbH • Berker GmbH & Co. KG • Bischoff Elektronik GmbH • Bosch & Siemens Hausgeräte GmbH • Brück Electronic GmbH (B.E.G.) • Bticino s.p.a. • Busch - Jaeger Elektro GmbH • Danfoss A/S • Dätwyler Kabel + Systeme GmbH • Dehn + Söhne GmbH & Co. KG • Eberle Controls GmbH • Eelectron srl • EIBMARKT GmbH • Electrak International Ltd. • Elektroanlagen Dieter Nagel • Elero GmbH • Elka-Elektronik GmbH • Elsner Elektronik GmbH • EMU Elektronik AG • Eutrac Stromschienen GmbH • F.W. Oventrop KG • Feller AG • Foresis SA • GE Grässlin GmbH & Co. KG • Gewiss S.p.A. • Gira Giersiepen GmbH & Co. KG • Griesser Electronic AG • Guangzhou Hedong Electronics Co. Ltd. (HDL) • Gustav-Hensel GmbH & Co. • Hager Holding GmbH • Heinrich Kopp AG • Herbert Waldmann GmbH & Co. KG • HTS High Technology Systems AG • Hugo Müller GmbH • Insta Elektro GmbH • IPAS GmbH • JEPAZ Elektronika spol, s.r.o. • Legrand S.A. • Licht Vision GmbH • Lingg & Janke OHG • Merten GmbH & Co. KG • Micro Innovation AG • Miele & Cie KG • Moeller Gebäudeautomation KG • Möhlenhoff Wärmetechnik GmbH • Novar GmbH • O.Y.L. Electronics SDN.BHD. • OAO „Research & Production Association SEM“ • Opternus Components GmbH • Oras Ltd • PKC Group Oy • Ritto GmbH & Co. KG • RTS Automation GmbH • S. Siedle & Söhne, Telefon- und Telegraphenwerke OHG • Schaeper Automation GmbH • Schlaps & Partner GmbH • Schneider Electric (Lexel AS) • SCHNEIDER Electric Industries S.A. • Schüco International KG • Siemens AG • Siemens Ltd. • Siemens Schweiz AG • Simon S.A. • Somfy Feinmechanik und Elektrotechnik GmbH • Stengler Gesellschaft GmbH • Tapko Technologies GmbH • Techem Energy Services GmbH • Techno Trend Systemtechnik GmbH • Tehalit GmbH • Teldat Security • Theben AG • Theodor Heimeier Metallwerk KG • Trialog • TridonicAtco GmbH & Co. KG • Viessmann - Werke GmbH & Co. WERK II • Vimar SpA. • Wago Kontakttechnik GmbH • Walther Werke • WAREMA electronic GmbH • Weinzierl Engineering GmbH • Wieland Electric GmbH • Wilhelm Huber + Söhne GmbH & Co. KG • Wilhelm Rutenbeck GmbH & Co. • WindowMaster A/S • Winkhaus Türtechnik GmbH & Co. KG • Woertz AG • Zennio Avance y Tecnología s.l. • Zumtobel AG Status: September 2006 Nous utilisons la NORME +++ 100 Sociétés +++ 70 Pays +++ 7000 Produits certifiés +++ 21.000 Utilisateurs ETS +++ 100 Centres de formation +++ 50 Partenaires scientifiques +++ www.konnex.org L’hôpital St.Olav à Trondheim, en Norvège, sera l’un des centres de soins les plus modernes d’Europe en 2015. The St. Olav University Hospital in Trondheim, Norway will be one of Europe’s most modern health centers by 2015. grand nombre de systèmes évolutifs de fabricants différents utilisant Ethernet et Internet comme une « autoroute de données ». Utiliser des systèmes standardisés garantit la sécurité d’inves tissement. Bénéfices pour les constructeurs et les exploitants Dans ce projet, la zone au tomation KNX a été intégrée au poste d’automation DESIGO-PX de Siemens Building Technologies en utilisant une méthode « d’in génierie rationnelle » avec des raccordements de points de données prédéfinis. Le constructeur et l’exploitant sont alors tous les deux gagnants. Les interfaces de série équipant le système DESIGO combinent la force des deux standards mondiaux. La projection standardisée BACnet-KNX Afin de simplifier l’intégra tion de KNX et BACnet, les deux organisations ont développé une projection standardisée qui est documentée dans l’annexe H.5 de la norme BACnet – « Utiliser BACnet avec KNX ». La comparabilité entre les « objets » BACnet et les blocs fonctionnels KNX forment la base de la projection standardisée, puisque leurs structures de données passèdent une sémantique identique. Les points de données KNX correspondent aux proprié tés de BACnet. Solutions The St. Olav Hospital is a company and university hospital in Norway’s middle region, covering 630,000 residents. The new health center will treat patients and carry out research and training. The first buildings opened in 2006 and the entire center will be ready by 2015. The hospital will cover a total area of 210,100 m2. Siemens won the contract to implement the building automation in the new center. The global KNX standard will be used to control lighting, sun protection and temperature in over 2,700 rooms. DESIGO INSIGHT will be used as the management system and the DESIGO PX automation stations will be used to integrate the KNX systems. DESIGO enables operational staff to access the systems remotely via Internet. The DESIGO PX stations are physically connected to the management system via Ethernet using the global BACnet standard on IP. Integrating KNX room automation into BACnet building automation system As a global standard for home and building automation systems, KNX has been implemented as standard at the field level in large projects for the last 15 years. Certification and guaranteed interoperability enable the development of project specific, multi-vendor systems with a large range of choice from nearly 7,000 product groups. The manufacturer and pro duct independent integration tool (ETS) ensures easy configuration. The BACnet standard continues to establish itself as the protocol for automation and management functions in large projects. Combining both standards in a single project enables the integration of numerous, future-safe systems from different manufacturers using Ethernet and the Internet as a “data highway”. Using standardized systems provides investment security. Benefits for constructors and operators In this project, the KNX room automation is being integrated with the DESIGOPX automation station from Siemens Building Technologies, using a “rational engineering” method with predefined data point connections. Both constructor and operator have equal benefits: The serial interfaces in the DESIGO system combine the strengths of both global standards. Standardized BACnet-KNX Mapping In order to simplify the integration of KNX and BACnet, both organizations have developed a standardized mapping which is documented in appendix H.5 of the BACnet Standard –“Using BACnet with KNX”. The comparability between the BACnet “object types” and KNX functional blocks forms the basis for the standardized mapping, since their data structures possess identical semantics. KNX data points correspond to BACnet properties. Richard Staub BUS-House staub@bus-house.ch www.bus-house.ch www.konnex.org Booth Hall 7, 130 Solutions La réduction des coûts avec une qualité de service optimale Cost Reduction with Optimum Service Quality Au centre de commande d’Infraserv Höchst, au Building Control Center, le système de contrôle du bâtiment et les données du système d‘automation fonctionnent main dans la main – les systèmes sont reliés par BACnet/IP. In the Infraserv Höchst Building Control Center, building control and automation system data run together – the systems are linked by BACnet/IP. Qu’est-ce que le centre d’affaires et complexe de bureaux Torhaus Westhafen situé à Francfort et le bâtiment abritant le laboratoire multi-usage du parc industriel de Höchst ont en commun ? La commande du bâtiment et les données du système d’automation des deux bâtiments fonctionnent ensemble au centre de commande de bâtiment d’Infraserv Höchst. Ici le chauffage, les dispositifs de ventilation, de climatisation et d’autres systèmes, tels que les systèmes de détection incendie et d’alarme d’ascenseur, sont surveillés et commandés 24h/24. Le contrôle intégré des sys tèmes d’automation du bâtiment est particulièrement important dans le parc industriel de Höchst. Ce secteur industriel de 4.6 km 2 , situé près de l’aéroport de Francfort, abrite plus de 80 entreprises, principalement issues des industries chimiques, pharmaceutiques et de biotechnologie, employant environ 22 0 00 personnes au total. Le centre de contrôle de bâtiment, installé par Infraserv Höchst, l’opérateur du parc industriel, garantit aux différentes compagnies résidantes que chaque anomalie rencontrée peut être corrigée immédiatement. C‘est une donnée importante et rassurante pour les labora- toires présents sur ce site et pour un secteur aussi sensible que celui de la recherche. Maintenant, un complexe de bâtiments situé en dehors du parc industriel – Torhaus Westhafen – est également relié au centre de commande. Les avantages de cette situation pour les clients : main d’œuvre et coûts réduits avec une gamme complète de services offerts – 24h/24h, 365 jours par an. certains impératifs techniques étaient en place. Pour limiter raisonnablement la gamme variée des systèmes de bus de terrain qui peuvent être employés, Infraserv Höchst utilise seulement les systèmes de bus internatio‑ nalement normés et les pro tocoles tels que la EIB, LON ou BACnet pour l’automation du bâtiment. Ainsi, peu importe quel constructeur fournit le système DDC ( Direct Digital Controls ). En utilisant le protocole standardisé BACnet au ni veau automation du système entre les DDC particuliers, les sections d’assemblage et Le centre de commande d‘Infraserv Höchst. The Infraserv Höchst Building Control Center. L’intégration de différents systèmes de bus Afin de réduire les coûts pour les clients, permettre en même temps d’utiliser la base de données pour saisir les données de fonctionnement, par exemple, poster des messages sur le statut de l’installation ou se connecter au système de lecture de compteur électrique, Infraserv Höchst a dû assurer que 22 BACnet France Journal 1 04/07 le système de gestion du bâ timent, il est garanti que les transmissions entre les systèmes, le bâtiment et le centre de commande sont normées. Cette formule idé ale peut être achevée dès le début dans le cas de nouveaux bâtiments, alors qu’avec les systèmes exis tants, la conversion BACnet est réalisée à l’aide de passerelles et de serveurs OPC. La visualisation est fournie par l’application Web « WebCtrl », qui supporte tous les serveurs et navigateurs Java-2-compatibles. Ici, tous points de données exigés sont représentés. La conversion avec les serveurs OPC Infraserv Höchst peut également intégrer dans le système du bâtiment les données des équipements de service fournis par différents fabricants. À cette fin, un ordinateur central OPC a été préalablement installé, via lequel plusieurs serveurs OPC convertissent les différents systèmes de bus en données OPC. Dans le parc industriel, la communication entre les différents systèmes fonctionne sans faille via l’infrastructure existante IP datanet. Des clients extérieurs peuvent être reliés au centre de commande du bâtiment via RNSI ou DSL. Les réseaux sont naturellement protégés contre l’accès non autorisé par des pare-feu. Le système mo derne de gestion d’immeubles permet à chaque entreprise de faire fonctionner leurs sites en toute sécurité et fiabilité. What do the business and office complex Torhaus West hafen in Frankfurt and the multi-purpose laboratory building in the Höchst Industrial Park have in common? Building control and automation system data from Solutions both buildings run together in the Infraserv Höchst Building Control Center. Here the heating, ventilation and air conditioning as well as other systems, such as the fire detection and elevator alarm systems, are monitored and controlled around the clock. Integrated control of building automation systems is particularly important in the Höchst Industrial Park. This 4.6 km2 industrial area, close to Frankfurt Airport, is home to more than 80 re sident companies, mainly from the chemical, pharmaceutical and biotechnology industries, employing about 22,000 people in total. The Building Control Center, installed by Infraserv Höchst, the Industrial Park operator, guarantees the individual resident companies that every fault can be corrected immediately. This is an essen tial requirement for sensitive research and laboratory areas. Now, a building complex situated outside the Industrial Park – Torhaus Westhafen – is also linked to the Building Control Center. The advantages of this for the customers are reduced manpower requirement and costs along with a complete service package – 24 hours a day, 365 days a year. Integration of Different Bus Systems In order to cut costs for customers and at the same time make it possible to use the data pool to collect operating data, for example, and post status messages or log meter readings, Infraserv Höchst had to ensure that certain technical requirements were in place. To sensibly restrict the diverse range of field bus systems that can be used, Infraserv Höchst employs only internationally standardized bus systems and protocols such as EIB, LON or BACnet for building automation. It does not matter which manu facturer supplies the DDCs (Direct Digital Controls). By using the standardized BACnet protocol at the automation level of system technology between the indivi dual DDCs, the assembly sections and the building control system, it is possible to ensure that communications both within the systems and building and with the Building Control Center are standardized. This ideal situation can be achieved from the outset in the case Le parc industriel de Höchst vu du ciel. Aerial view of the Höchst Industrial Park. of new buildings, while with existing systems, conversion to BACnet is accomplished with the aid of gateways and OPC servers. Visuali zation is provided by the web-based application “WebCtrl”, which supports all Java-2-compatible servers and browsers. Here, all the required data points are represented. Conversion with OPC Servers Infraserv Höchst can also integrate data into the system from building service equipment supplied by different La structure du système d‘automation du bâtiment au parc industriel de Höchst. The structure of the Building Automation System at the Höchst Industrial Park. manufacturers. For this purpose, a central OPC computer was initially installed, through which several OPC servers convert different bus systems into OPC data. Within the Industrial Park, communication between the individual systems operates smoothly through the existing IP datanet infrastructure. External customers can be linked to the Building Control Center via ISDN or DSL. The networks are, of course, protected from unauthorized access by firewalls. The modern building management system enables every company to run their plants safely and reliably. Roland Schwab Infraserv GmbH & Co. Höchst KG roland.schwab@infraserv.com www.infraserv.com BACnet France Journal 1 04/07 23 GRAPHICS VIDEO ALARMS PERSONNEL RECORDS SCHEDULES BADGES REPORTS PROGRAMS SETPOINTS TREND GRAPHS Complete Overview – Anytime, Anywhere When you have buildings managed from different systems and organizations, it can be hard to tell what is really going on in the facilities. And what it is costing. There is a better way: Andover Continuum™ is the most powerful, integrated BACnet® building management system in the industry, offering: • • • • Native BACnet at all levels, BTL-listed Wireless BACnet Field Bus for cost-effective installations Integrated Building Automation and Security The industry’s first PDA-based BACnet Service Tool Together with our parent company, Schneider Electric, our complete building solutions give you a single approach for controlling all of a building’s systems, from the power line to the bottom line. Take control – turn to TAC. To learn more about Open Systems for Building IT®, visit www.tac.com. TAC was awarded the Frost & Sullivan 2006 Excellence in Technology Award in the field of Integrated Building Systems. www.tac.com BACnet insight Une introduction à BACnet An Introduction to BACnet Hans Symanczik1 Histoire de BACnet Le développement de BACnet s’est fait courant 1987 aux USA. BACnet fut créé par l’ASHRAE, une asso ciation d’ingénieurs américains dédiés à la CVC. Bien avant que ce protocole ne soit reconnu com me norme mondiale, l’intérêt était déjà considérable et international. En juin 1995, BACnet fut offi ciellement accepté et publié par l’ASHRAE, et la même année fut reconnu comme standard améri cain par ANSI. Les premiers pro duits à avoir communiquer entre eux via BACnet ont été lançés sur le marché en 1996, faisant passer le protocole BACnet du virtuel au réel avec des applications concrètes. BACnet est rapidement devenu un candidat idéal pour être reconnu à la fois comme norme européenne ( CEN ) et internationale ( ISO ). Ce fut le cas dès l’année 2004. De nombreux projets majeurs ont été menés depuis tels que ceux du Reichstag, le Parlement Allemand à Berlin, par la Technology Associa tion for Parliament Buildings, ou bien encore le projet de l’Hôpital de la Charité de Berlin. Ils sont équipés d’une série de dispositifs is sus de fabricants différents et com muniquent entre eux, via BACnet, ce qui démontre que ce protocole est en parfaite adéquation avec les exigences. Avec un standard ISO, BACnet est le protocole mondial reconnu pour l’équipement d’auto mation du bâtiment. BACnet n’est lié à aucun matériel Quels sont les avantages qu’offre BACnet et qui lui permettent de s’affirmer? Bien, tout d’abord, le fait que BACnet soit approprié à tous les systèmes possibles d’auto mation du bâtiment et notamment, les systèmes CVC, les systèmes de sécurité et de lutte anti-incendie. Il consiste en un modèle de don nées orienté objet qui représente la configuration et le fonctionnement d’une grande variété de dispositifs de contrôle et d’exploitation. Il dé finit également les messages et ser vices échangés entre les dispositifs selon le modèle client/serveur. Le LAN et le WAN peuvent être utilisés pour la transmission d’infor mations, tandis que de simples con nections bifilaires Ethernet et TCP/ IP sont quant à elles, disponibles. Ceci est précurseur des nouvelles possibilités établies dans l’art de communiquer des données. Un au tre atout majeur de BACnet est qu’il n’est lié à aucun matériel particu lier. Donc vous n’avez pas besoin de puces spéciales ou de média de com munication fait sur mesure. BACnet est un protocole qui peut être mis en application sur pratiquement n’importe quel matériel de base. Ceci élimine les coûts de licence à l’usage de BACnet, signifiant seule ment le médium, tel que Ethernet 10Mbits/s, qui dicte la vitesse de transmission. La structure de BACnet BACnet est basé sur le modèle ob jet où chaque fonction des équipe ments d’automation ( tels que les entrées, les sorties, les circuits de contrôle, et les horaires ) est repré sentée sous la forme d’une collec tion d’informations ( ex : un objet ). Chaque objet a ses propriétés in cluant ses valeurs actuelles, son emplacement physique, les para mètres de graduation, les limites d’alarme et la description de la fonction de chaque objet. Actu ellement, le standard fournit 28 types d’objets et chaque système BACnet est une accumulation d’objets représentant le système. Par exemple, une unité terrain de 16 entrées digitales pourrait être représentée avec 16 objets binaires d’entrée. Les systèmes avec une quantité aléatoire de complexité correspondent à un nombre de ces objets élémentaires du même type et leurs propriétés. Ce modèle sig nifie que BACnet peut être utilisé avec n’importe quelle application. Le second composant principal de Hans Symanczik, Kieback&Peter GmbH & Co. KG, est membre du conseil BIG-EU. Hans Symanczik, Kieback&Peter GmbH & Co. KG, is member of the BIG-EU Advisory Board. 1 BACnet définit les services BACnet ( messages ou services ) que les systèmes BACnet échangent entre eux. Le standard définit 35 services répartis en 5 catégories : Services d’Alarme et d’événements, Services d’accès au fichier, Services d’accès à l’objet, Services de gestion à distance des dispositifs, Services terminaux virtuels. D’autres objets et services sont en cours de discussion pour être inté grés au standard. Ceci pour dé montrer également que BACnet peut être progressivement étendu et développé. Les derniers composants BACnet incluent les technologies réseaux applicables tels que la vitesse, le débit, les extensions, le degré de dissémination du stand ard existant au regard des besoins d’équipement d’automation du bâ timent. La gestion en réseau via Ethernet est standard de nos jours et présente dans tous les bâtiments. Il est donc aisé d’utiliser le câblage existant pour les besoins des équipe ments d’automation du bâtiment. Depuis 1999, le fonctionnement di rect de BACnet est possible sous IP ( l’Internet Protocol ), bien qu’une autre option fort intéressante soit proposée, le protocole PTP, ce qui permet de raccorder BACnet aux connections modem. Ceci signifie que BACnet est le seul standard de communication qui constitue des règles pour une communication claire et établie. Mais BACnet peut également être actionné via une paire torsadée ( MS/TP ), ARCnet et même le protocole LonTalk d’Echelon ( utilisant juste l’infrastructure ). Le plus est que BACnet est en perpétuelle évolution en ce qui concerne ses technologies réseau et des nouveaux systèmes qui sont intégrés au standard BACnet. En ce moment, le standard radio ZigBee et la transmission BACnet basée sur les services Web sont en train d’être intégrés au standard. Application de BACnet BACnet a été conçu pour une uti lisation exclusive au sein des bâti ments et immeubles. Dans ce sec teur, les exigences actuelles et à venir seront intégrées au standard BACnet. En d’autres termes, BACnet se concentre sur ce secteur et il n’y a aucun plan d’application de BACnet dans le process, la restaura tion ou la technologie d’aviation. Le lobby BACnet Des groupes d’intérêts et d’utili sateurs ont fait leur apparition en liaisons avec BACnet et les fabri cants allemands représentés au sein du BIG–EU créé en 1998. Ces groupes rassemblent les utilisa teurs et les fabricants de produits BACnet qui ont un intérêt com mun à faire la promotion, la vente, la formation et la certification de produits BACnet. Ces différents groupes d’utilisateurs communi quent en permanence les uns avec les autres et assurent que BACnet reste bien un protocole universel et n’entraîne pas le développement de formes hybrides, de pâles copies nationales. L’essentiel est surtout de se dire qu’une communication ouverte commence toujours avec une compréhension verbale. De plus les membres partager et s’échanger les informations entre eux, au-delà même des frontières nationales, afin d’adapter et de transformer significativement le standard BACnet. L’une des prio rités de BIG et de BACnet Inter national ( BACnet Manufacturers Association ) aux USA est de trou ver un mécanisme de test et de cer tification pour les produits BACnet. Le laboratoire de test de BACnet a été conçu pour réaliser les tests des systèmes BACnet selon des critères et scripts de test comparables en tout point et pour tout le monde. Cela a généré les premiers systèmes testés alors que la certification uni forme selon les mesures européennes est une perspective d’avenir. Comment BACnet va-t-il progresser ? Les applications initiales étai ent réalisées dans les domaines du chauffage, de la ventilation, de l’air conditionné, sans oublier tous ces produits de plus en plus nombreux issus d’entreprises exerçants dans les secteurs de l’alarme, la sécu symanczik@kieback-peter.de – www.kieback-peter.de BACnet France Journal 1 04/07 25 BACnet insight rité, les équipements d’éclairage. En d’autres termes, BACnet n’est pas simplement fait sur mesure pour répondre à un quelconque besoin sectoriel, mais il est commun et se focalise sur des applications dans les bâtiments. The History of BACnet The development of BACnet began in the United States in 1987, borne by ASHRAE, (the American Socie ty of Heating, Refrigerating & AirConditioning Engineers), an Amer ican engineer’s society. But even while the protocol was being de veloped, there was considerable in ternational interest. In June 1995, BACnet was officially accepted and published by ASHRAE and in the same year it was also recognised by ANSI as an American standard. The first products to communicate with one another via BACnet were brought to market in 1996, trans forming BACnet from a paper tiger to a real-life protocol with actual applications. BACnet then quickly advanced to becoming a candidate for a Euro pean standard (CEN) and a global standard (ISO) which became a re ality in 2004. Some major projects were launched such as the Techno logy Association for Parliament Buildings with the German Reichs tag Parliament in Berlin and Berlin‘s Charité hospital. They have a whole series of devices from various manu facturers communicating with one another via BACnet, which demons trates that this protocol is in tune with requirements. With an ISO standard BACnet is the key global protocol in building automation equipment. BACnet is not linked to any hardware What benefits does BACnet offer to enable it to assert itself? Well, one thing is the fact that BACnet is suited to all kinds of building au tomation systems including HVAC, fire and security systems. It consists of an object-orientated data model that represents the configuration and operation of a wide variety of operating and control devices. It also defines messages and services Binary Input Multi-state Input File Binary Output Multi-state Output Program Binary Value Multi-state Value Schedule Analog Input Loop Trend Log Analog Output Calendar Group Analog Value Notification Class Event Enrollment Averaging Command Device LifeSafetyPoint LifeSafetyZone Global Group Accumulator Pulse-Converter Trendlog-Multiple Eventlog Les 28 objets BACnet. The 28 BACnet objects. exchanged between devices on the client-server principle. Varying lo cal (LAN) and wide-area networks (WAN) can be used for trans mitting information and simple two-wire Ethernet and TCP/IP connections are available. This is pioneering new frontiers in stateof-the-art data communications. A major benefit is the fact that BACnet is not linked to any parti cular hardware so you don‘t need either special chips or tailor-made communication media. BACnet is simply a protocol that can be im plemented on virtually any hard ware basis. That eliminates license fees for using BACnet, meaning only the medium – such as Ethernet 10 MBit/s – dictates the transmis sion speed. The Structure of BACnet BACnet is based on the object mo del where each function of automa tion equipment (such as inputs, out puts, control circuits and schedules) are shown as a collection of infor mation (i.e. an object; ). Each ob ject has properties including cur rent values, physical locations, scaling parameters, alarm limits and a description of the object function. These days, the standard provides 28 object types and each BACnet system is an accumulation of ob jects representing the system. For instance, a field unit with 16 digital inputs could be represented with 16 binary input objects. Systems with a random amount of complexity correspond to a number of these elementary objects of the same type and their properties. This model means that BACnet can be used for virtually any application. The second essential component of 26 BACnet France Journal 1 04/07 BACnet is defining BACnet services (messages or services) that BACnet systems exchange with one another. The standard defines 35 services in five categories including: Alarm and event services, File access services, Object access services, Remote device management services and Virtual terminal services. Other objects and services are under discussion for being included in the standard, which also demonstrates that BACnet can be progressively expanded and developed. The latest components of BACnet include ap plicable network technologies such as speed, throughput, expenditures and degree of dissemination selected from existing standards according to the needs of building automation equipment. Ethernet networking is standard cabling in buildings these days, which means that it is easy to use this cabling for the needs of building automation equipment. Since 1999, direct BACnet oper ation has been possible over IP (the Internet protocol), although an other fascinating option is the PTP protocol, that enables BACnet via modem connections. That means that BACnet is the only communi cation standard that also constitutes rules for establishing and clearing communication. But BACnet can al so be operated via twisted pair (MS/ TP), ARCnet and even the Echelon LonTalk protocol (just using the in frastructure). What‘s more, BACnet is constantly evolving in terms of its network technologies and new systems are being included in the BACnet standard whenever they come to the fore. Right now, the radio standard ZigBee and BACnet transmission based on web services are being included in the standard. Applying BACnet BACnet was conceived exclusively for use in buildings. Present and future building requirements will be integrated into the BACnet stand ard. In other words, it is distinctly focused and narrowed down, mean ing there are no plans for applying BACnet in process, restaurant or aviation technology. BACnet Lobby Global interest and user groups have sprung up in connection with BACnet with German manufac turers represented in the European BACnet Interest Group that was set up in 1998. These groups bring together users and manufacturers of BACnet products who have the common interest of promoting the marketing, training and certifica tion of BACnet. These different user groups are in communication with one another to make sure that BACnet stays a universal protocol and does not develop national dia lects or varieties. The bottom line is the fact that open communication always starts with verbal under standing. Another thing members do is to talk to one another and ex change information over national and continental borders in order to meaningfully transform and adapt the BACnet standard. A major priority of the BACnet interest groups and BACnet Inter national (formerly the BACnet Manufacturers Association) in the United States is finding a uniform testing and certification mechanism for BACnet products. The BACnet BTL test laboratory was set up to test BACnet systems according to globally uniform and thus compa rable test criteria and test scripts. This generated the first tested systems while uniform certification according to European measures is a prospect for the future. How will BACnet progress? All of the initial applications were in heating, ventilation and air con ditioning equipment, although there are more and more products from companies for alarm, security and lighting equipment. In other words, BACnet is not simply tailor-made to the needs of any special sector, al though there is a common focus on building applications. BACnet insight BACnet dans les environnements de technologies de l‘information BACnet in IT Environments Dr. Simon Ginsburg1 Clemens Schaumann2 Frank Schubert 3 Comme vous avez pu le décou vrir dans les éditions précédentes de ce journal, BACnet supporte six normes de connexion réseau différentes. Parmi ces standards, vous trouverez également le pro tocole Internet IP. Par conséquent, cela suppose d’envisager l’intégra tion dans les environnements IT existants dès que des composants d’automation du bâtiment sont à connecter à un réseau, réseau bien évidemment existant au préala ble. Cependant, pour l’exécution, 3 secteurs essentiels doivent être considérés dès la phase de planifica tion, ces sujets seront développés de maniere plus détaillés dans l’article ci-dessous. 1. Exigences techniques pour le réseau Basé sur le standard ETHERNET largement utilisé, BACnet supporte même 2 protocoles : ISO8802-3 et le protocole Internet IP. Les rou teurs de dernière génération ( aussi appelés « routeurs Layer 3 » ) trans portent seulement les télégrammes IP et non les paquets ISO8802-3, ce qui les rend inappropriés pour une couverture totale, notamment dans les grands réseaux. BACnet/ IP fournit un soutien direct au pro tocole Internet et est ainsi parfaite ment approprié pour l’intégration dans les réseaux existants. Les impératifs techniques sui vants sont à mettre en application : BACnet/IP est basé sur le proto cole UDP et communique via un port ( valeur défaut est le port 47808, en nombre hexadécimal, soit 0xBAC0, qui peut être facile ment rappelé ). Tant que les rou teurs échangent les tables de chemi nement les uns avec les autres et 1 2 3 qu’au moins un de ces routeurs est reconnu par BACnet comme « pas serelle par défaut », la porte est ouverte pour la communication entre les dispositifs BACnet. Messages diffusés Cependant, durant l’intégration dans les environnements IT, la question est de savoir si les mes sages à diffusion générale ( télé grammes à tous les membres de réseau ) qui doivent être trans portés, doivent être résolus. Entre autres utilisations, de tels messages sont employés dans BACnet pour identifier les membres BACnet au moyen de télégrammes du type : « qui-est-qui » ou « Je-suis… ». Puisque ces messages doivent être traités par tous les membres ( même par des dispositifs non BACnet ), les messages sont nor malement bloqués entre différents segments de réseau ( par exemple entre les groupes de travail ou les étages ). Le problème peut être résolu en utilisant un BBMD ( BACnet Broadcast Management Device ), là où le BBMD détecte des télé grammes d’émission dans son propre segment et les renvoie à une liste de diffusion prédéfinie d’autres BBMD qui sont supposés à recevoir l’émission. Le BBMD à distance renvoie alors l’émission. Alors que le télégramme est pack agé comme un télégramme unidi rectionnel, les routeurs existants transporteront ces messages. Cette technique est appelé « two hop » et est l’application standard pour les BBMD. Attribution dynamique d´adresse D’autres exigences techniques doi vent être considérées en ce qui concerne l’attribution dynamique d’adresse ( DHCP ). Dans la plu part des cas, les composants d’automation du bâtiment sont Dr. Simon Ginsburg, Saia-Burgess Controls AG et Dr. Simon Ginsburg, Saia-Burgess Controls AG and Clemens Schaumann, t.a.c., sont membres du working group marketing du BIG-EU. Clemens Schaumann, t.a.c., are members of the BIG-EU Working Group Marketing. Frank Schubert, MBS GmbH, est membre du conseil du BIG-EU. Frank Schubert, MBS GmbH, is member of the BIG-EU Advisory Board. simon.ginsburg@saia-burgess.com clemens.schaumann@tac.com frank.schubert@mbs-software.de statiquement assignés aux dispo sitifs d’automation reliés au niveau gestion. Donc l’attribution d’une adresse IP statiquement détermi née, est exigée dans de nombreuses applications. Transformation d´adresses Dans les départements IT, le thème relatif à la traduction d’une adresse réseau ( NAT ) sur vient de temps en temps quand les pare-feu sont utilisés. Cela si gnifie qu’un dispositif est assig né à une adresse publique utilisée depuis l’extérieur, qui est différen te de l’adresse privée utilisée en interne. Comme les équipements BACnet émettent leur adresse IP dans un « télégramme I-am » ( dans ce cas l’adresse utilisée en interne ), cette méthode ne peut être appliquée. A ce jour, la nouvelle génération IPv6 de plan d’adresse IP n’est pas encore supportée par BACnet, mais cela est prévu et le standard actuel IPv4 lui, est supporté. Le VPN ( Réseau Virtuel Privé ) est tout à fait approprié à BACnet et permet le transport de messa ges entre deux dispositifs ou ré seaux sans que les autres ne soient capables de décoder les télé grammes. Il faut noter que les im plémentations IKE/IPSec fréquem ment utilisées ne sont pas toujours compatibles avec le pare-feu NAT, à moins que l’implémentation sup porte le RFC3947 ( négociation du NAT transversal au sein du IKE ). Comparé à cela, les implémenta tions basées sur SSL-PN sont tou jours compatibles avec le NAT. Pour de plus amples informa tions à propos de la sécurité réseau, vous pouvez télécharger le supplé ment 135-2004g sur le site Internet www.bacnet.org. A l’avenir, cela permettra l’utilisation de mécanis mes directs de sécurité au sein des dispositifs BACnet. 2. Les aspects organisationnels Une multitude de questions orga nisationnelles doit être résolue du rant l’intégration dans les réseaux existants ou l’établissement de réseaux propres à l’automation du bâtiment. Indépendamment du nombre maximum de dispositifs envisagés, d’autres questions cru ciales se posent notamment en ma tière de sûreté opérationnelle mais également de sécurité réseau. Automatisation de bâtiment et IP Parmi d’autres tâches, les adminis trateurs IT sont responsables de la protection du réseau contre les intrus et doivent assurer un fonc‑ tionnement fiable. Cependant, l’au‑ tomation du bâtiment est plus qu’une source de friction, car les technologies de l’information ti reront également avantages des conditions climatiques au sein des centres informatiques assu rant l’exploitation fiable et l’iden tification des défauts à temps. Glossaire BBMD : Dispositif de gestion de diffusion BACnet, reçoit des télégrammes et les transmet en tant que télégrammes unidirectionnels aux autres BBMD présents sur le réseau. Two-hop technique : Les télégrammes unidirectionnels des BBMD sont envoyés en tant qu’ « unicast » au récepteur BBMD. One-hop technique : Cette méthode requiert des routeurs (IP) spéciaux qui convertissent les télégrammes unidirectionnels des BBMD sans l’intervention d’un BBMD récepteur dans les émetteurs. UDP : Le protocole datagramme utilisateur est un protocole réseau sans connexion minimum, une partie de la couche transport de la famille Internet Protocol. TCP : Le Protocole de Contrôle de Transmission ( TCP ) est un protocole de transport fiable, connecté au sein des réseaux informatiques. BACnet France Journal 1 04/07 27 integrate If integration becomes more complex, success will depend upon your choice of system integrator. At Honeywell Building Solutions we offer proven expertise in the delivery of critical automation and integration solutions to hospitals, the pharmaceutical manufacturing industry, airports, commercial real estate and factories. Innovative products such as Excel Web® with BACnet® and LON® interfaces and the open building management system, Honeywell Enterprise Buildings IntegratorTM, can help you to cut operating costs, improve productivity and maximise the return on your investment. You can rely on our experience and open standards: Honeywell. Honeywell GmbH – Honeywell Building Solutions Kaiserleistraße 39, 63067 Offenbach, Germany Phone: +49 69 8064-723 – hbs.info@honeywell.com – www.honeywell.de/hbs © 2006 Honeywell GmbH. All rights reserved. BACnet insight Glossary Presque à tout moment, les com posants d’automation du bâtiment requièrent une infrastructure opé rationnelle, même lorsque la char ge réseau est extrêmement élevée, comme par exemple, celle due aux opérations de backup de données. Cela doit impérativement être pris en compte dans la phase de con ception d’une QoS ( Qualité de Service ). En pratique, l’intégration ré seau échoue fréquemment car les appréhensions sont trop élevées de part et d’autre séparant ainsi les réseaux qu’ils soient établis ou fonctionnels. Responsabilité du Réseau D’autres questions organisa tionnelles sont la responsabilité de l’intervention sur le réseau et le temps imparti pour le faire, et qui est autorisé aux interventions sur le réseau. Ceci est particulièrement marquant sur les réseaux avec des données personnelles et d’autres données sujettes à la protection de données. La question est de savoir si l’enregistrement du trafic réseau pourrait être autorisé durant la mise en service. En tout cas, la nomination d’une personne responsable pour le réseau d’automation du bâtiment est indispensable, comme pour les définitions spécifiques BACnet, comme les noms des dispositifs et les nombres et la documentation du réseau. 3. Coûts / Bénéfices Bien qu’à première vue l’utilisation des réseaux existants semble être faisable et rentable, plusieurs autres facteurs doivent être pris en considération pour une analyse coûts-bénéfices. Dans de nombreuses organi sations, les départements IT agis sent en tant que centre de profit interne et offrent leurs services, comme la mise à disposition de l’infrastructure réseau, aux autres départements. Ceci implique des coûts mensuels en sommes eu ro à deux chiffres par connexion réseau, bien que les coûts de main tenance et de réparation des com posants de réseau défectueux soient inclus dans la somme. L’expérience a montré que la mise en place d’un réseau sépa ré serait trop coûteuse dans le cas où quelques raccordements réseau seulement sont nécessaires, mais l’investissement dans un réseau d’automation du bâtiment pour un plus grand nombre de connex ions pourrait être rentable dans un délai de quelques années. Cepen dant, dans le dernier cas, le groupe d’automation du bâtiment est alors responsable pour la maintenance et l’exploitation du réseau. Plannification totale Comme mentionné précédemment, la question de la compétence et de la responsabilité est un élément à ne pas sous-estimer pour l’inté gration car elle est en même temps une raison potentielle d’échec. Considérer l’automation du bâti ment comme une partie de la tech nologie de l’information seulement parce que les dispositifs ont des raccordements au réseau, serait aussi absurde qu’ignorer les princi pes de base de la gestion de réseau pendant la planification et remet tre à plus tard leur considération jusqu’à la phase d’implémentation. Il est évident que la prise en considération devrait être faite pendant la phase de planification et que le département IT, lui aussi, devrait être impliqué dans ce pro cess dès le début, de manière à ce que l’intégration soit un succès. BACnet supports a total of six different network connection stan dards. Among these standards you will also find the IP internet proto col. Therefore, it is worth consid ering the integration into existing IT environments when compo nents of building automation are to be connected in a network and such a network already exists. For implementation, however, three essential areas must be consid ered already in the planning phase. These topics are covered in more detail in this article. 1. Technical requirements for the network Based on the widely used Ethernet standard, BACnet supports two protocols: ISO8802-3 and the IP internet protocol. State-of-theart routers (also called “layer 3 routers”) only transport IP tele grams and no ISO8802-3 pack ets, which makes them unsuitable for complete coverage, particularly in large networks. BACnet/IP pro vides direct support of the internet protocol and is thus perfectly suited for the integration into existing net works. BBMD: BACnet Broadcast Management Device; receives broadcast telegrams and transmits them as unidirectional telegrams (unicast) to the other BBMDs in the network. Two-hop technique: The unidirectional telegrams of the BBMDs are sent as “unicast” to the receiving BBMD. One-hop technique: This method requires special (IP) routers that convert the unidirec tional telegrams of the BBMDs without intervention of the receiving BBMD into broadcasts. UDP: The user datagram protocol is a minimum connectionless network protocol as part of the transport layer of the internet protocol family. TCP: The transmission control protocol is a reliable, connection-oriented transport protocol in computer networks. The following technical require ments apply: BACnet/IP is based on the UDP protocol and commu nicates via a port (default is port 47808, in hexadecimal notation this is 0xBAC0, which can be easily remembered). As long as the rout ers exchange the routing tables with each other and at least one of these routers is known to BACnet as “default gateway”, the door is open for communication between BACnet devices. BACnet Broadcast Management Device However, during integration into IT environments the issue, whether broadcast messages (telegrams to all network members) are to be transported, must be resolved. For example, such messages are used in BACnet to identify the BACnet members by means of “who-is-who” or “I-am-…” telegrams. Since these messages must be processed by all members (even by non-BACnet devices), the broadcast messages normally are blocked between dif ferent network segments (for ex ample between work groups or floors). The problem can be solved by using a BBMD (BACnet Broadcast Management Device), where the BBMD detects broadcast telegrams in its own segment and forwards them to a predefined list of other BBMDs that are supposed to re ceive the broadcast. The remote BB MDs then in turn resend the broad cast. Since the telegram is packaged as a unidirectional telegram, the existing routers will transport these messages. This technique is called “two hop” and is the standard application for BBMDs. Dynamic Address Allocation Other technical requirements have to be considered with respect to dynamic address allocation (DHCP). In most cases, building automation components are statically assigned to the connected automation de vices on management level, there fore the allocation of a statically determined IP address is required in many applications. Network Address Translation In the IT departments, the topic of network address translation (NAT) occasionally arises, particu larly when firewalls are used. This means that a device is assigned an externally used public address that is different from the internally used private address. Since BACnet de vices broadcast their IP address in an “I-am-telegram” (in this case the internally used address), this meth od cannot be applied. As of today, the next generation of IP address scheme IPv6 is not yet supported by BACnet, but this is planned for the future. The current standard IPv4 is supported. Transport via VPN VPN (Virtual Private Network) is well suited for BACnet and permits the transport of messages between two devices or networks without others being able to decode these telegrams. It must be noted that the frequently used IKE/IPSec imple mentations are not always compat ible with firewall NAT, unless the implementation supports RFC3947 (negotiation of NAT transversal in the IKE). Compared with this, im plementations based on SSL-PN are always compatible with NAT. BACnet France Journal 1 04/07 29 BACnet insight For more information on the sub ject of network security you can download Addendum 135-2004g from www.bacnet.org. In future, this allows the use of direct security mechanisms in BACnet devices. 2. Organizational aspects A multitude of organizational is sues must be resolved during inte gration into existing networks or during establishment of own net works for building automation. Apart from the projected maximum number of devices, other crucial is sues are operational safety and net work security. Building Automation and IT Among other tasks, IT administra tors are responsible for protecting the network against intruders and ensuring reliable operation. How ever, building automation is more than just a source of friction. Also the IT will benefit from climatic conditions in the computer cent er ensuring reliable operation and allowing timely recognition of faults. At nearly all times the build ing automation components require an operational infrastructure, even when the network load is extreme ly high, for example, due to data backup operations. This must be absolutely taken into account when designing a QoS (Quality of Ser vice) scheme. In practice, network integration frequently fails because apprehensions are too high on both sides so that separate networks are established or operated. Responsibility for the Network Other organizational issues are the responsibility for network trouble shooting and the timeframe for it, and who is allowed interventions in the network at all. Particularly in networks with personal data and other data subject to protection, the question arises whether network traffic recording should be allowed during commissioning. At any rate, naming a responsible person for the building automation network is in 30 BACnet France Journal 1 04/07 dispensable, also for BACnet-speci fic definitions such as device names and numbers and for documenting the network. mation network for a larger number of connections could pay off within a few years. In the latter case, how ever, the building automation group is responsible for maintenance and operation of the network. 3. Cost / Benefit Although at first glance the use of existing networks seems to be feasi ble and cost-effective, several other factors must be taken into account for a cost-benefit-analysis. In many organizations, IT de partments act as an internal profit center that offers its services, such as the provision of the network in frastructure, to the other depart ments. This involves monthly costs of double-digit Euro sums per net work connection, though of course the cost for maintenance and repair of faulty network components is in cluded in the sum. Experience has shown that the establishment of a separate network would be too ex pensive when only few network connections are needed, but the in vestment in an own building auto Comprehensive Planning As mentioned earlier, the question of competence and responsibility is a factor not to be underestimated for integration and at the same time a potential reason for failure. To consider building automation as part of IT only because the devices have network connections makes as little sense as to ignore network ing principles during planning and postponing their consideration until the implementation phase. Altogether, a comprehensive consideration should be made dur ing the planning phase and the IT department, too, should be involved in the process at an early stage to make the integration a success. BACnet insight BACnet intègre la sécurité – un nouvel objet et exemple « la porte d’accès » BACnet integrates Security – New objecttype “Access Door” Christian Müller 1 Quand en 1995, l’ASHRAE ( So ciété américaine des ingénieurs en chauffage, réfrigération et climati sation ) s’est intéressée de près au standard BACnet ®, elle cherchait à fournir les moyens d’assurer la communication entre différents systèmes de commande CVC is sus de divers fournisseurs. Après dix ans d‘expérience avec BACnet, la norme a été approuvée. Jugée très satisfaisante, elle est même devenue une norme internationale ( EN ISO 16484-5 ). BACnet, orienté objet, souti ent également une communication standardisée avec d’autres fonc tions telles que les dispositifs de sé curité des personnes ( Life Safety ) Object property (R)ead (W)rite Conformance Code Property values Significations des propriétés Present_Value W Required LOCK UNLOCK PULSE-UNLOCK IN_ALARM FAULT OVERRIDDEN Status_Flags R Required OUT_OF_SERVICE 1 Alarme de porte . État d‘erreur. La porte est outrepassée par le mécanisme d’un dispositif local BACnet . La porte est hors service . Door_Status W Optional CLOSED OPENED UNKNOWN Feedback statut porte . La porte est fermée . La porte est ouverte . Le statut de la porte n’est pas connu. Lock-Status W Optional LOCKED UNLOCKED PENDING_LOCK PENDING_UNLOCK Feedback concernant la dernière commande de porte La porte est verrouillée . La porte n’est pas verrouillée . La porte devait être verrouillée mais est (toujours) déverrouillée . La porte devait être déverrouillée mais est (toujours) verrouillée . Door_Members R Optional Ces catégories contiennent les références des objets BACnet qui se caractérisent par des dispositifs Entrée/Sortie, des disposi tifs d’autorisation ou des programmes ou d’autres objets associés à la porte physique . Door_Alarm_ State R Optional Cette propriété est exigée là où l’Objet Porte d’Accès soutient le signal d’alarme intrinsè que. Un algorithme prendra en compte les différents états : Statut_Verrouillage , Statut de la Porte et Valeur_actuelle ou Information des autres propriétés des ob jets, afin de générer une alarme de porte . Type d‘objet porte d‘accès. Access Door Object Type. BACnet et „Life Safety“ BACnet® est sur le marché de la sé curité des personnes depuis de nom breuses années maintenant. Son existence est soutenue par la créa tion de 2 objets et des services adap tés. L’un est appelé « the Life Safety Point Object » ( cela pourrait être un détecteur de fumée, une alarme ou un photocopieur supervisé ). L’autre, appelé, « the Life Safety Zone Object » ( par exemple un bus avec des détecteurs de fumée ap partenant à une zone dédiée ). Cette La porte est commandée en statut verrouillée . La porte est commandée en statut non verrouillée . La porte est commandée en statut non ver rouillée au maximum du Door_Pulse_time . configuration permet aux parefeu d’être directement rattachés à un système de gestion intégré utilisant le protocole BACnet. Alors quels sont les avantages de cette solution ? Les plans d’étage peuvent être utilisés pour visualiser l’emplace ment des détecteurs de feu et de fumée. L’intégration avec un système de vidéosurveillance aide à la locali sation et prise de décision rapide Christian Müller est membre du conseil de BIG-EU, chef du working group marketing et directeur marketing et communication à Honeywell, Honeywell Building Solutions, Offenbach. Christian Müller is a member of the BIG-EU Advisory Board, head of the BIG-EU Working Group Marketing and Manager Marketing and Communications of Honeywell GmbH, Honeywell Building Solutions, Offenbach, Germany. et précise en cas d’incendie. Un fonctionnement homogène de toutes les fonctions qui propose une réponse adaptée et rapide à tous les événements critiques, malgré le stress de la situation rencontrée. Moins d’espace est nécessaire dans la centrale étant don né que le système de gestion de détecteurs d’incendie peut être supprimé. BACnet et « Security » En mars 2006, un nouveau supplé ment au standard ANSI/ASHRAE 135-2004 a été présenté au public pour examen. Ce complément ouvre peu à peu l’industrie de la Sécurité à BACnet. Il est décrit com me un nouveau type d’objet appelé : Access Door Object Type. Le nouvel objet « The Access Door » Le nouvel objet « The Access Door object type » est une abstraction de l’interface de communication pour une porte physique et son contrôle d’accès électronique. La porte peut être assignée à divers dispositifs comme l’accès à carte, les lecteurs biométriques et la technologie de fermeture de portes ( verrous motor isés, cylindres, contacts de portes ). Une « porte » peut tout aussi bi christian.mueller@honeywell.com – www.honeywell.de/hbs BACnet France Journal 1 04/07 31 En « Mémoire+&!*)%'#)+!5)!++!& de la Démocratie » une Gestion %71 intelligente et intégrée de bâtiments travaille. !&+$$!&+-)#3))!&1,,+'%+!'& 6/*+%!&+)+!'& Intégration du système 61,,+'%+!'&**/*+% Système d’automation de bâtiments 6 &!*technique *1,%&%&+ Gestion de bâtiments 6&+)+!$!+/&%&+ Gestion intégrée des installations 6)')%&'&+)+!& Performance Contracting 6&+)!)+! ) !+*$2*,&& Solutions de sécurité intégrées Johnson Controls France 46-48 avenue Kleber 92702 Colombes France ' &*'&'&+)'$*'&+)'$*)',()%&/6'&*!(&6 **& Téléphone + 33146131600 Téléfax +33 47 8093 83 $'&6. 6!$&),)"' &*'&'&+)'$*'% (0!$!*+&3) Spécialistes des !&+$$!&+1, bâtiments intelligents. BACnet insight en être une barrière dans un park ing. Certaines des propriétés impor tantes et spécifications courantes de l’objet sont présentée ci-dessous. firmed to be very satisfactory and thus it became an international standard (EN ISO 16484-5). The BACnet object orientated design also supports standardised communication with other func tions like Life Safety devices. When ASHRAE (the American So ciety of Heating, Refrigerating and Air-Conditioning Engineers Inc.) rolled out the BACnet® stand ard in 1995 it sought to provide a means of enabling communica tion between different HVAC con trol systems from various vendors. After ten years of experience with BACnet, the standard was con BACnet and “Life Safety” BACnet® has been in the Life Safety market for several years now. Its presence is supported by the crea tion of two objects and the appro priate services. One object type is called the Life Safety Point Object (this could be a smoke detector, a siren or a monitored printer), the other is the Life Safety Zone Ob ject (for example a bus with smoke detectors belonging to a dedicated zone). This configuration allows the fire panels to be brought into an integrated management system us ing the BACnet protocol. The ad vantages of this solution include: Existing floor plans can be used to show the location of smoke and fire detectors. Integration with video surveil lance can help to get a fast and precise overview in the event of a fire. Equal operation of all functions supports a proper and fast re sponse to critical events when under stress. Lecteur biométrique. Biometrical tracking. Object property (R)ead (W)rite Conformance Code Property values Present_Value W Required LOCK UNLOCK PULSE-UNLOCK Status_Flags R Required IN_ALARM OVERRIDDEN OUT_OF_SERVICE Door_Status W Optional Meaning of the property The door had been commanded to the locked state. The door had been commanded to the unlocked state. The door had been commanded to the unlocked state for the maximum of the Door_Pulse_time. Door alarm. Door has been overridden by a local BACnet device mechanism. Door cannot be commanded. CLOSED OPENED UNKNOWN Door status feedback The door is closed. The door is open. The door status unknown. LOCKED UNLOCKED PENDING_LOCK PENDING_UNLOCK Feedback regarding the last door command The door is locked. The door is unlocked. The door was commanded to locked bus is (still) unlocked. The door was commanded to unlocked bus is (still) locked. Lock-Status W Optional Door_Members R Optional This category holds references to BACnet objects which represent I/O devices, authorisation devices or schedules or other objects associated with the physical door. Door_Alarm_ State R Optional This property is required where the Access Door Object supports the Intrinsic Alarming. An algorithm will take into account the states of Lock_State, Door_State and Present_Value or Information from other objects’ properties to generate a door alarm. Less floor space is required for the management system because a separate supervisory system for the fire panels is no longer required. BACnet and “Security” In March 2006 a new Addendum “f” to the ANSI/ASHRAE Stand ard 135-2004 was presented to the public for review. This addendum starts to open BACnet to the secu rity industry. It describes a new ob ject type called Access Door Object Type. The new object type “Access Door Object Type” The Access Door object type is an abstraction of the communication interface for a physical door and the accompanying electronic access control. The door can be assigned to various devices such as access card or biometrical readers and the door locking technology (motor driven lockers, cylinder, door con tacts). A “door“ can also be a barri er in a parking deck for example. Some of the important object properties of the current object specification are shown in the table. Bernhard Isler und HansJoachim Mundt specify the new BACnet objects for access control systems on the subsequent pages. BACnet France Journal 1 04/07 33 BACnet insight Les nouveaux objects BACnet pour des systèmes de controles d’accès New BACnet objects for Access Control Systems Bernhard Isler1 Hans-Joachim Mundt2 Aujourd’hui la norme BACnet étend son champ d’application et incorpore les systèmes de sécurité. Actuellement les standards et services BACnet supportent les systèmes de détection d’in cendie et d’intrusion ( Fire- and Intrusion Detection Systems). Le groupe de travail Sécuri té et Sûreté des Personnes, Life Safety and Security Working Group ( LSS-WG ), un sous groupe du ASHRAE SSPC-135 travaille sur de futures extensions notamment en ce qui concerne les systèmes de contrôle physique d’accès ( Physical Access Control Systems – PACS ), la vidéo surveillance ( Video Supervision ou CCTV ) et les sys tèmes de sécurité audio ( Audio Security Systems ). Les parties de ses extensions du PACS sont déjà approuvées par un rapport d’en quête publique ( voir supplément f 135-2004 ) tandis que d’autres sont proches de la discussion du SSPC-135. Un livre blanc sur la nor malisation PACS est disponible sur le site Internet www.bacnet.org. Les systèmes audio et vidéo se ront rassemblés sous un standard unifié, sous le titre générique : Les Systèmes Multimédia de Sé curité ( Multimédia Security Sys tems MMS ). Ces actions de nor malisation sont coordonnées avec l’Association de l’Industrie de la Sécurité ( SIA ). Systèmes de contrôle d’accès physique ( PACS ) Un PACS est employé pour sécu riser des zones d’accès contrôlées en limitant cet accès aux seules personnes autorisées ( c’est à dire les utilisateurs ) à entrer dans ces secteurs géographiques spécifiés ( bâtiments, départements, salles, ascenseurs, étages, etc. ). Les portes ou les portes commandées agissent en tant que points phy siques d’entrée et de sortie. À ces points de contrôle, l’utilisateur doit s’identifier via les lecteurs mis à sa 1 2 Schéma 1 : Décomposition fonctionnel d’un PACS disposition ( par exemple lecteurs de cartes, pavés tactiles, scanners biométriques ). Le model BACnet du PACS Bien au delà de la CVC, le PACS possède une fonctionnalité spéci fique : Gestion d’un nombre important d’événements Base de données utilisateurs im portantes et élaborées, identi‑ fiants et droit d’accès, reproduits sur de nombreux dispositifs Haute fréquence de changements de configuration Relations complexes entre les objets. Afin de couvrir tout ceci, 7 nou veaux objets BACnet ont été in troduits, mais pas de nouveaux services BACnet. Un nouvel algo rithme d’événements a été déve‑ loppé et les objets existants tels que le calendrier et l’horaire ont été ré-utilisés (Schéma 1). L’intérêt du modèle BACnet étant les 3 interfaces ( voir les lolly pops ). Le graphique suivant fournit une vue d’ensemble des objets et de leurs relations avec ces interfaces (Schéma 2): Bernhard Isler, Siemens Building Technologies. Hans-Joachim Mundt, Siemens Building Technologies. hans-joachim.mundt@siemens.com bernhard.isler@siemens.com www.siemens.de/sbt 34 BACnet France Journal 1 04/07 Interface du lecteur d’identité Cette interface est fournie par un procédé de lecteur d’identité. El le comprend un ensemble d’objets BACnet qui représente l’entrée des données d’identification ( éléments d’authentification ) et les éléments physiques du lecteur. L’object d’entrée de l’élément d’identification Ce nouvel objet fournit les élé ments d’authentification issus de la pièce d’identité. < Tout Type > D’autres éléments d’un lecteur d’identité peuvent être modelés en utilisant les objets existants de BACnet. Comme exemple, l’indi cateur DEL qui peut être représen té par une sortie binaire. Interface d’authentification et d’autorisation Cette interface est fournie par un process d’authentification et d’autorisation. Les objets BACnet de cette interface permettent la configuration, le contrôle, le suivi d’événements, l’authentification et la délivrance d’autorisation. L’objet point d’accès Ce nouveau type d’objet repré sente le point d’authentification et d’autorisation avant que l’accès soit autorisé. Tout authentification et événement d’autorisation ( alar mes et transactions ) est édité par les objets de ce type. L’objet zone d’accès Ce nouveau type d’objet repré sente une zone protégée avec les points d’entrée et de sortie. La fré quence d’occupation, l’annonce des entrées « qui est présent », le support de détection des sorties, le dispositif de pistage d’identité sont quelques unes des caractéristiques associés à ce nouvel objet. Les ob jets de ce modèle ne renvoient pas les événements, mais aident les objets Point d’Accès à évaluer les événements et les alarmes. L’objet accès identifié Ce nouveau type d’objet repré sente un conteneur d’éléments rela tifs à l’authentification, tels qu’une carte, un code PIN, la biométrie etc. Les droits d’accès sont spéci fiés en référence aux objets Droits d’Accès. L’objet droits d’accès Ce nouveau type d’objet représente une gamme de droits d’accès, chacun incluant une condition externe ( typiquement quand le droit d’accès est validé ) où l’accès est autorisé et pour quel niveau de menace le droit est validé. La base des droits d’accès peut être héri tée d’une structure hiérarchique et soutenir les réglages NIST rela tifs au modèle RBAC ( Role Based Access Control ). L’objet accès utilisateur Ce nouveau type d’objet représente une personne individuelle, un BACnet insight groupe ( par exemple une entité organisationnelle ) ou une source. L’objet horaire et calendrier Ces objets sont utilisés pour spéci fier la validité des fenêtres de temps des droits d’accès. < Tout type > Les objets d’autre type sont suscep tibles d’être utilisés pour la spéci fication des conditions extérieures afin de valider les droits d’accès. L’objet porte d’accès L’interface est fournie par le pro cédé de Contrôle et de Surveillance des Portes Mécaniques ( MDCMP ). Il comprend un ensemble d’objets BACnet permettant aussi bien la surveillance abstraite et le contrôle de la porte que la surveillance et le contrôle spécifique des éléments simples de portes. Type d´objet accès porte Ce nouveau type d’objet représente de manière abstraite une porte ou un portail. Les événements sont renvoyés via l’algorithme existant CHANGE_OF_STATE / chan gement d’état. Les références des autres objets indiquent ce que les éléments particuliers font au ni veau de la porte. Les systèmes de Sécurité Multimédia ( MSS ) Ceci couvre la surveillance visuelle ( systèmes CCTV ) et les systèmes audio. L’unification est devenue évidente, parce que les deux types de système traitent les flux de don nées. Le modèle BACnet couvrira la commande de la capture, la transmission, l’enregistrement et le playback, l’analyse et l’affichage. Le flux de transmission lui-même est en dehors de la portée de BACnet, laissé aux normes exis tantes pour la transmission numé rique et analogique. Un livre blanc est en cours de travail au sein du groupe LSS-WG, semblable à celui concernant le PACS. Perspectives Le LSS-WG s’est fixé comme prio rité de finaliser la normalisation du modèle PACS via MSS. Toute con tribution est bien évidemment la bienvenue. Pour tout contact, visi tez le site Internet : www.bacnet.org The Life Safety and Security Work ing Group (LSS-WG) is the subgroup of ASHRAE SSPC-135, that is working on extensions for Physical Access Control Sys tems (PACS), Video Supervi sion (or CCTV) and Audio Secu rity Systems. Parts of the exten sions for PACS has already been through a first public review (see Addendum f to 135-2004 and the article of Christian Müller on pre vious pages), while others are close before discussion at SSPC-135. A white paper on the PACS standardization is available at www.bacnet.org. Video and Audio systems will be covered by a uni fied model, under the working title Multimedia Security Systems (MSS). These standardization acti vities are coordinated with the Security Industry Association (SIA). Physical Access Control Systems (PACS) A PACS is used to secure accesscontrolled zones by restricting access to geographic areas (build ings, departments, rooms, eleva tors, floors, etc.) to only those per sons or assets (i.e. users) who are allowed to enter the zone. Con trolled doors or gates act as phys ical ingress and egress points. At these points the user has to identify themselves at credential readers (e.g. card readers, keypads, biomet ric scanners). The BACnet Model of a PACS PACS have some specific function ality beyond HVAC: Large number of transactionbased events. Large and sophisticated data base of users, credentials and rights, replicated over many devices. High frequency of configuration changes. Complex relationships between objects. To cover this, seven new BACnet object types, but no new BACnet services were introduced. One new event algorithm was developed, and existing objects such as calendar and schedule were reused. First a PACS was decom posed on a functional level (Figu re 1) of interest for the BACnet model were the three interfaces (see the lollipops). The following provides an over view of the objects and their rela tions in these interfaces (Figure 2). Credential Reader Interface This interface is provided by the Credential Reader Process. It com prises a set of BACnet objects which represent credential data (i.e. au thentication factors) input and credential reader physical elements. Authentication Factor Input Object Type This new object type provides authentication factors read from credentials. <Any Type> Other elements of a credential reader may be modeled using exist ing BACnet objects. As an example, indicator LEDs may be represented by a Binary Output object. Authentication & Authorization Interface This interface is provided by the Authentication & Authorization Process. The BACnet objects of this interface enable configuration, con trol and event reporting of authen tication and authorization. Schéma 2 : ´Vue d´ensemble du modèle PACS BACnet. Access Point Object Type This new object type represents the point of authentication and author ization before access is granted. BACnet France Journal 1 04/07 35 BACnet insight Any authentication and authori zation events (alarms and trans actions) are reported by objects of this type. Access Zone Object Type This new object type represents a secured zone with ingress and egress access points. Occupancy counting, “Who’s In” reporting, passback de tection support or credential track ing are some of the features of this object type. Objects of this type do not report events, but support Access Point objects to evaluate events and alarms. Figure 1: Functional decomposition of a PACS Access Credential Object Type This new object type represents a container of related authentication factors, such as card, PIN, biome tric, etc. Access rights are specified through referencing Access Rights objects. cally when the right is valid), where access is allowed, and for which threat level the right is valid. Base access rights may be inherited for hierarchical structuring, e.g. to support setups according NIST‘s Role Based Access Control (RBAC) model. Access Rights Object Type This new object type represents a collection of access rights, each in cluding an external condition (typi Access User Object Type This new object type represents an individual person, a group (e.g. or ganizational entity) or an asset. Schedule and Calendar Object Type Such objects are used to specify validity time windows of access rights. Access Door Interface This interface is provided by the Mechanical Door Control & Moni toring Process. It comprises a set of BACnet objects enabling abstract monitoring and control of the door, as well as specific monitoring and control of single door elements. Access Door Object Type This new object type (see adden dum f) represents a door or gate of any kind in an abstract way. Events are reported through the existing CHANGE_OF_STATE algorithm. References to other objects indicate, which individual elements make up a door. <Any Type> Object of other type may be used to represent individual elements of a door. Multimedia Security Systems (MSS) This covers both video surveillence (a.k.a. CCTV systems) and Audio systems. Unification became ob vious, because both types of sys tems deal with data streams. The BACnet model will cover control of capture, transmission, recording & playback, analysis and display. The stream transmission itself is outside the scope of BACnet, left to exist ing standards for digital and analog transmission. A white paper is be ing prepared at the LSS-WG, simi lar to the one for PACS. Outlook The LSS-WG has set its priority to complete standardization of the PACS model over MSS. Any contri butions are welcome. For contacts and details see www.bacnet.org. Figure 2: Overview of BACnet PACS model 36 BACnet France Journal 1 04/07 BACnet insight Les objets et fonctions pour l’intégration de systèmes Objects and functions for system integration HANS KRANZ1 Le standard mondial pour l’auto mation du bâtiment et les systèmes de commande EN ISO 16484 est actuellement composé de 4 parties corrélées. Les sections 5 et 6 BACnet en font partie en tant que Partie 2 « Matériel » et Partie 3 « Fonc tions ». Dans un projet hétéro gène, comme par exemple un projet comprenant des systè mes d’origines diverses, les pro duits et fonctions dédiés, les systèmes et sites de production doivent être harmonisées les uns avec les autres. Les limites claires et non équivoques de fourniture et la responsabilité de la coordina tion, la fonctionnalité et la garan tie sont essentielles parce que les partenaires ne sont pas respon sables sous contrat aux autres, mais seulement par le maître d’ouvrage, la plupart du temps le propriétaire du bâtiment. La nor me contractuelle de base est four nie par le standard international EN ISO 16484. Multiple différent, mais sys tèmes inter-opérants sont désignés sous le nom de systèmes intégrés. L’intégration est réalisée via la mise en application de points de données communs, fonctions in ter-agissantes et par l’application d’un protocole de communication normalisé aux interfaces. Des solutions alternatives au proto cole normé BACnet seront payées en principe avec une perte de franchise. Les objets de communication et les fonctions BACS Avec leurs propriétés et les procé dures BACnet, les types d’objet BACnet sont l’élément sémantique le plus important du protocole BACnet parce qu’ils décrivent la signification et le sens des données. Ces données deviennent l’informa tion distincte pour les utilisateurs et le logiciel, c.-à-d. pour l’interpré tation assistée par ordinateur dans le cadre de l’automation et de la commande du bâtiment. C’est ce en quoi BACnet se distingue d’autres protocoles de communication. Pendant les 30 dernières années la liste de points de données définis dans la norme VDI/3814 était pour un ingénieur conseil alle mand BACS le seul et unique outil lui permettant de spécifier la fonc tionnalité aux sites de production. La VDI est l’association des in génieurs allemands. Nous disons norme VDI/3814 suivant le stand ard « ASHRAE/BACnet », parce que les fonctions BACS de la VDI ont été adoptées dans la partie 3 de la norme globale BACS tandis que le standard BACnet a été adopté dans la partie 5 EN ISO. A l’origine, les fonctions BACS pour la liste de points de données ont été développées en tant que spécifica tions principales allemandes pour les appels d’offres ( du GAEB* ) alors qu’elles ont été acceptées pour la directive 3814 de la VDI et ont alors été adaptées globalement dans la norme EN ISO 16484-3. Le nombre de propriétés d’objet BACnet pour transmettre et visua liser résulte des fonctions exigées BACS. En remplissant la liste des fonctions BACS ( BACS FL ) le consultant détermine les sujets d’information d’un point de don nées. Pour l‘évaluation de la quan tité de travail d’ingénierie, il est im portant que l’information requise – avec les « propriétés » BACnet – et la limite pour la réalisation des engagements soit clairement deter minées. Les fonctions standardisées BACS aident à arranger la commu nication entre tous les partenaires impliqués dans la planification et l’exécution plus efficace et moins coûteuse que toute autre chose. Attention: Il est fortement déconseillé d’interpréter les intitulés des types de fonction des BACS FL soi-même. L’énoncé officiel dans la norme BACS EN ISO 16484-3 :2005 (et l’explication dans VDI 3814-1) sont exclusivement valables. Appels d’offres BACnet Avec l’utilisation du BACS FL dans les projets d‘intégration de système, Hans Kranz est membre du Conseil Présidental du DIN, membre exécutif du VDI-TGA, chef de projets des standards ISO et CEN BACS. Hans Kranz is member of the DIN Presidial Board, member of the executive board of VDI-TGA, project leader of the ISO and CEN BACS standards. 1 le chevauchement ou la duplica tion des services et des composants d’ingénierie ( matériel et licences ) peuvent être évités. Seuls les noms des points aux serveurs et aux clients BACnet, les fonctions de communication et quelques fonctions dédiées à l’exploitant sont communs aux différents systèmes des fournisseurs. Les fonctions d’entrée et de sortie phy siques peuvent être trouvées seu lement une fois dans le système combiné. Dans la liste de quanti tés et d’articles offerts ( caractéris tiques ), la compilation spécifique au projet des fonctions BACS dans le BACS FL décrit la fonc tionnalité associée au site de production donné et compor te le travail opérationnel complet d’ingénierie et la mise en service pour le point de données parti culier. Par conséquent dans les spécifications des offres, aucu ne autre somme forfaitaire n’est accréditée pour l’ingénierie, la mise en service, la maintenance, l’instruction et la documentation. Ces positions sont habituellement incalculables. Les fonctions spé cifiées du standard BACS peuvent être consolidées dans une somme forfaitaire à la passation du con trat. En Allemagne pour BACS il y a les VOB/C DIN 18386 ( les conditions générales du contrat technique ) intégrant la déter mination des fonctions type du standard BACS comme unité de facturation. Si un Système de Contrôle de Bâti ment, ou un Système de Gestion de l’Energie respecte les exigences du standard EN ISO 16484, il peut alors être désigné comme un sys tème de contrôle et d’automation du bâtiment ( BACS). ( ISO 16484-2,3.31 ). The global standard for building automation and control systems EN ISO 16484 comprises 4 corre lated parts today. BACnet in Parts 5 and 6 belongs to this as to Part 2 “Hardware” and Part 3 “Func tions”. In a heterogeneous project, i.e. with systems of different origin, the dedicated functions of prod ucts, systems and plants have to be harmonized with each other. Clear and unambiguous stipulated limits of supply and the responsibility for co-ordination, functionality and warranty is essential because the communication partners are not liable under a contract to each other, but only with the award ing authority – mostly the building owner. The normative contractual basis is provided by the Internation al Standard EN ISO 16484. Multiple different, but inter-op erating systems are referred to as in tegrated systems. The integration is accomplished by implementation of common data points, interacting functions and by application of the adequate standardized communica tion protocol at the interfaces. Al ternatives to the globally stand ardized protocol BACnet in princi ple will be paid with a loss of open ness. Communication objects and BACS functions The BACnet object types with their properties and BACnet procedures are the most important semantic el ement of the BACnet protocol be cause they describe the meaning and sense of data. Through this data is distinct information for users and software, i.e. for computer aided interpretation in the context of building automation and con trol. This is what distinguishes BACnet from other communication protocols. During the last 30 years the data points list defined in the VDI/3814 standard was for a German consult ing engineer of BACS the only and outstanding tool for specifying the functionality of plants. VDI is the association of German engineers. We say VDI/3814 standard follow ing the “ASHRAE/BACnet-Stand ard”, because the VDI BACS func tions have been adopted in Part 3 of the global BACS standard as the BACnet-Standard was adopted in the EN ISO Part 5. The BACS func tions for the data points list were ² GAEB = commission commune pour la technologie d’information du bâtiment ³ GAEB = Joint Committee for Information Technology in the Construction Industry (Fed. Ministry for Construction, Germany) hans@kranz.com BACnet France Journal 1 04/07 37 BACnet insight originally developed for the Ger man master specification for tenders (from the GAEB³) then they have been accepted for the VDI Guideline 3814 and then globally taken over for EN ISO 16484-3. The number of BACnet object properties to trans mit and to display results from the required BACS functions. By filling the BACS function list (BACS FL) the consultant determines the mat Warning: do not self interpret the function type headlines of the BACS FL. Strictly the word ing of the official statement in the BACS standard EN ISO 16484-3:2005 (resp. the explanation within VDI 3814-1) is valid. ters of information of a data point. For the estimation of the quantity of engineering work it is of signifi cance that the required information – with BACnet the “properties” – and the border for fulfillment of obligations is clearly committed. The standardized BACS functions help to arrange the communica tion between all involved partners in planning and execution more efficient and at lower cost than anything else. The tendering of BACnet With use of the BACS FL in sys tem integration projects the over lapping or duplication of engineer ing services and components (hard ware and licences) can be avoided. Only the point names at BACnet servers and clients, the communi cation functions and some selected operator functions are common for different contractor‘s systems. The physical input and output functions can be found only once in the com bined system. In the list of bid items and quan tities (specifications) the project specific compilation of the BACS functions in the BACS FL describes the associated plant functionality and comprises the complete ready for use engineering work and com missioning for the particular data point. Therefore in the specifica tions for tenders no further lump sum positions are accredited for engineering, commissioning, hand over, instruction and documenta tion. These positions usually are in calculable. The specified standard BACS functions may be consolidat ed into a lump sum at awarding of the contract. In Germany for BACS there is the VOB/C DIN 18386 (General Technical Contract Con dition) with the determination of the standard BACS function types as billing unit. If a building control system, building management system, or building energy management sys tem complies with the require ments of the EN ISO 16484 standard series, it should be des ignated as a building automation and control system (BACS). (ISO 16484-2, 3.31) Types d’objet BACnet et Types de fonction BACS BACnet object types and BACS function types Le tableau montre la cohérence de types d’objet BACnet et types de fonc tion BACS. Les abréviations pour les types d’objet ne font pas partie de la norme, mais il est recommandé de ne pas les « réinventer » au choix. The table shows the interrelationship of BACnet object types and BACS function types. The abbreviations for object types are not part of the global standard, but should not be “invented” arbitrarily. BACnet-Object type, Original language, Abbr. German translation Data point / Function type, BACS Function list (Section.Column) Relevance und Entry in the BACS Functon list 1. Accumulator ACC Counting (binary input), 1.4 In case of system integration as common communicative function 2.4, resp. 7.1. For measuring sensors with pulse output for counting and totalization of values over time. With exact adoption to the displayed value of the physical counter and with corresponding pre-adjustment for the accuracy. 2. Analog Input AI Measuring, 1.5 In case of system integration as common com municative function 2.5 resp. 7.1. e. g. measuring temperature 3. Analog Output AO Positioning, 1.2 In case of system integration as common com municative function 2.2 resp. 7.1. e. g. positioning command or actuating signal for control valve 4. Analog Value AV Virtual analog DP In case of system integration as common com municative function 2.2, 2.5, resp. 7.1. Digital presented analog value, e.g. the result of a calculation 5. Averaging AVG Virtual analog DP In case of system integration as common com municative function 2.2, 2.5, resp. 7.1. Digital presented analog value as the result of a statistical function with mean, minimum, maximum and variance 38 BACnet France Journal 1 04/07 BACnet insight 6. Binary Input BI Notification (binary input state), 1.3 In case of system integration as common com municative function 2.3 resp. 7.1. e.g. plant state, status, alarm 7. Binary Output BO Switching, positioning, 1.1 In case of system integration as common communicative function 2.1 resp. 7.1.. e. g. command on/off, open/close 8. Binary Value BV Virtual binary DP In case of system integration as common com municative function 2.1, 2.3, resp. 7.1. Notification, binary state, e.g. 0/1 of a logic interlock function 9. Calendar CAL System parameter Holiday list, not a BACS function, included in 6.4 Time schedule 10. Command CMD Virtual DP, in case of system integration as common management-communication function for complex object types 7.2. Command for execution of several predefined activities, e.g. from optimization functions 6.3 to 6.13 and operator function 8.2; 11. Device DEV Basic system parameter, in case of system inte gration as virtual DP 7.2., e.g. for watchdogfunctions Properties of nodes with BACnet objects; 12. Event Enrollment EE Basic system parameter, to specify in a standard description for the entire project. Specification of event types for fixed reactions on events/alarms, included in the standard BACS functions; 13. Event Log ELOG Virtual DP, in case of system integration as common management-communication function for complex object types 7.2. Transmission of a list with event states and time stamps, 7.3, may also be used for BACS function 7.4; 14. File FIL System function File transfer, e.g. for configuration data, programs or backup (archiving); is part of BACS-software; 15. Global Group GGRP Virtual DP, in case of system integration as common management-communication function for complex object types 7.2. Grouping of input values from various objects in the BACS network; is part of BACS functions 3.6, 6.1, 6.2, 7.3, 7.4, 8.2. 16. Group GRP Virtual DP, in case of system integration as common management-communication function for complex object types 7.2. Grouping of input values from various objects in the same device; is part of BACS functions 3.6, 6.1, 6.2, 7.3, 7.4, 8.2. 17. Life Safety Point LSP complex input object type as common manage ment-communication function 7.2. nformation about the properties for life safety applications in the network. Derived actions are corresponding BACS functions. 18. Life Safety Zone LSZ Virtual DP, in case of system integration as common management-communication function for complex object types 7.2. Combination of life safety objects, e.g. for fire alarming loops, fire sections, alarming devices. Application for e.g. 7.3, 7.4 (reports), 8.2 dynamic insertion in user interfaces, Derived actions are corresponding BACS functions. Virtual DP, in case of system integration as common management-communication function for complex object types 7.2. Properties (attributes and parameters) of control loop functions; as part of BACS functions 5.1-5-8, 7.3, 7.4, 8.2. 19. Loop LP BACnet France Journal 1 04/07 39 BACnet insight 20. Multi-state Input MI Multi state notification, 1.3; in case of system integration as common communicative function per stage, 2.3 resp. 7.1. Properties (attributes and parameters) of control loop functions; as part of BACS functions 5.1-5-8, 7.3, 7.4, 8.2. Multi-state Output MO Multi state command, 1.1, in case of system in tegration as common communicative function per stage, 2.1 resp. 7.1. Logic output state coded as a figure, e.g. for commands off, slow, fast,… Each stage counts as a BACS function in the BACS FL. 22. Multi-state Value MV Virtual multy state DP, iIn case of system in tegration as common communicative function 2.1, 2.3, resp. 7.1. Logic state coded as a figure, e.g. state definition 1,2,3,… Each stage counts as a BACS function in the BACS FL. 23. Notification Class NC Basic system parameter, to specify in a standard description for the entire project. Time and destination depending dedication of alarm and event notifications, included in the corresponding BACS functions; 24. Program PR Complex object, in case of system integration as common management-communication function for complex object types 7.2. Access to a program in a BACnet device, e.g. to load and start this. The program is to be described. 25. Pulse Converter PC Mass/quantity counting, 1.4 In case of system integration as common communicative function 2.4, resp. 7.1. For counting a quantity over a given time inter val, e.g. for cars, water quantity. Also for peri odic power measuring as for load shedding, not for tenant billing (see Nr. 1 Accumulator). 26. Schedule SCHED Virtual DP, in case of system integration as common management-communication function for complex object types 7.2. Schedule for execution of repeating activities and specification of exceptions, is part of the BACS function 6.3, is required for 6.5 to 6.7 and 6.12/6.13. Trend Log TLOG Virtual DP, in case of system integration as common management-communication function for complex object types 7.2. Subscription to a value for COV reporting to report a trend 7.3, may also be used for historical data base 7.4. 21. 27. 28. Trend Log Multiple TLOGM Virtual DP, in case of system integration as common management-communication function for complex object types 7.2. Sources ISO 16484-2:2004-08, Building Automation and Control Systems (BACS), – Part 2: Hardware; 102,70 EURO. ISO 16484-3:2005-01, Building Automation and Control Systems (BACS), – Part 3: Functions; 117,30 EURO. ISO 16484-5:2003-11, Building Automation and Control Systems (BACS), – Part 5: Data communication protocol; 203,11 EURO. ISO 16484-6:2006-04, Building Automation and Control Systems (BACS), – Part 6: Data communication - Conformance testing; 218,70 EURO. VDI 3814-1 en: Building automation and control systems (BACS) – System basics, multilingual; 131,50 EURO VDI 3814-2 en: - Legislation, technical rules, multilingual; 36,70 EURO VDI 3814-3 en: Advices for technical building management – design, operation, maintenance, multilingual; 53,40 EURO VDI 3814-4 en: - Data points list und functions – Examples, multilingual; 169,70 EURO VDI 3814-5 en: system integration (in preparation), VDI 3814-6 en: graphical specification of interlock tasks (in preparation). 40 BACnet France Journal 1 04/07 Subscription to multiple values from various objects in the BACS network for COV repor ting to report trends 7.3, may also be used for historical data base 7.4. DIN EN ISO 16484-2, Ausgabe:2004-10, Systeme der Gebäudeautomation (GA) – Teil 2: Hardware (ISO 16484-2:2004); 117,70 EURO. DIN EN ISO 16484-3, Ausgabe:2005-12, Systeme der Gebäudeautomation (GA) – Teil 3: Funktionen (ISO 16484-3:2005); 130,40 EURO. DIN EN ISO 16484-5, Ausgabe:2004-08, Systeme der Gebäudeautomation – Teil 5: Datenkommunikationsprotokoll (ISO 16484-5:2003); Englische Fassung, CD-ROM, 367,80 EURO. DIN EN ISO 16484-6, Ausgabe:2006-04, Systeme der Gebäudeautomation – Teil 6: Datenübertragungsprotokoll - Konformitätsprüfung (ISO 16484-6:2005); Englische Fassung, CD-ROM, 318,80 EURO. VDI 3814 Blatt 1, Ausgabe:2005-05, Gebäudeautomation (GA) – Systemgrundlagen, de, 131,50 EURO VDI 3814 Blatt 2, Ausgabe:2005-05, Gebäudeautomation (GA) – Gesetze, Verordnungen, Technische Regeln, de, 36,70 EURO VDI 3814 Blatt 3, Entwurf, Ausgabe: 2006-04, Gebäudeautomation (GA) – Hinweise für das Technische Gebäudemanagement - Planung, Betrieb und Instand haltung, de, 53,40 EURO VDI 3814 Blatt 4, Ausgabe:2003-08, Gebäudeautomation (GA) – Datenpunktlisten und Funktionen – Beispiele, de, 169,70 EURO VDI 3814 Blatt 5, (Überarbeitung in Vorbereitung) Gebäudeautomation (GA) – Systemintegration, de, VDI 3814 Blatt 6, (in Vorbereitung) Gebäudeautomation (GA) – Darstellung von Steuerungsaufgaben, de Produits Products BACnet Test Framework – Tests de conformité automatisés à partir de 200 BACnet Test Framework – Automated Conformance Tests from 2007 Aujourd‘hui les tests de conformité BACnet sont seulement disponibles en tant que tests manuels. Ceci complique la reproductibilité dans le sens où les coûts de documentation sont extrêmement élevés. Today, conformance tests for BACnet are only available as manual tests. This complicates reproducibility and due to the higher effort for documentation, significantly increases costs. Le logiciel BACnet Test Framework ( BTF ) de MBS rend les tests BACnet automatisés disponibles et permet des tests faciles, rentables et reproductibles, non seulement en ce qui concerne les tests de conformité mais également pour la garantie de la qualité ou les applications semblables au sein des tests et analyses automatisés. Structure du logiciel Le logiciel, fonctionnant sous Microsoft Windows®, est formé de 4 composants principaux, chacun fournissant une partie de la fonctionnalité complète : 1. Le protocole BACnet – pile : ce service permet la communication avec les dispositifs BACnet connectés. La pile est basée sur la technologie LOD ( Charge à la demande ), la commutation étendue de ce service devient obsolète. 2.La machine-script-Python : Python est un langage script puissant et simple d’utilisation. Il permet à un utilisateur pas encore formé, d’écrire ses propres scriptes pour concevoir ses propres procédures de tests automatisés. 3. L’interface utilisateur : cette application est le « centre de la mise en scène » où les plans de tests sont façonnés, où les résultats sont visualisés et l’analyse effectuée. Les informations entre l’interface utilisateur et la machine-script sont transferées via TCP/IP, permettant l’installation sur deux systèmes différents et ainsi le découplage des deux process. 4. La base de données SQL : Elle est directement connectée à l’interface utilisateur et inclut le standard BACnet dans de multiples tables. Au-delà, les projets et leurs résultats respectifs y sont mémorisés. tronique PICS ( Protocol Implementation Conformance Statement ) EPICS, où les propriétés du dispositif sont listées. Dans le premier test, l’uniformité d’EPICS, c’est à dire son intégrité et l’exactitude d’EPICS sont contrôlées. Le visuel n°1 montre les résultats d’un tel test de l’uniformité d’EPICS. Si l’EPICS est complet et correcte concernant la syntaxe, le plan de test peut être établi. Le logiciel soutient le process en sélectionnant les tests selon le profi l du dispositif. Si un test dépend d’autres tests, alors ces derniers sont intégrés dans le plan. De plus, le logiciel permet d’ajouter des scripts établis par l’utilisateur au plan de test pour exploration individuelle. Cela fournit une large gamme d’applications bien au delà des tests de confor- mité. Le BTF avec sa structure très flexible est qualifié pour tous les types de tests automatisés et permet la définition, dans l’édition standard ou premium, de ses propres scripts, rapports et évaluations. Cela assure la parfaite fi abilité de BACnet test Framework pour des test effectués sur le long terme ou des applications similaires. Les résultats sont sauvegardés, basés sur une évaluation OK/ERREURS dans la base de données, mais peuvent être manuellement retravaillés en ajoutant un commentaire. Le logiciel a été introduit dans le laboratoire de test WSP de Stuttgart au cours du 4ème trimestre 2006. Depuis 2007, les tests automatisés BACnet sont disponibles ici et le logiciel estmis à votre disposition en même temps par MBS. Exemple d’une procédure de test : En premier lieu, le dispositif à tester et ses propriétés sont à introduire dans la trame de test, utilisant le format élec- BACnet France Journal 1 04/07 41 Produits Products profile. If a test depends on further tests, these dependent tests are also included. Furthermore the user may include own tests to the test plan. L’interface utilisateur du BACnet Test Framework. The user-interface of the BACnet test framework. The software BACnet Test Framework (BTF) from MBS makes automated BACnet tests available and allows easy, cost-effective and reproducible tests, not only for conformance testing but also for quality assurance or similar applications in automated testing and analysis. Software-structure The software, running on Microsoft Windows®, is based on four main components, each providing one part of the full functionality: 1.The BACnet protocolstack: This service allows communication to the connected BACnet devices. The stack is based on the LODTechnology (=Load on Demand), extensive switching of this service becomes obsolete. 2.The Python-scriptengine: Python is an easy-to-use, but powerful scripting language. This allows untrained users after a short time to write their own scripts to design own automated testprocedures. ous tables as well as the test projects and their results. 3.The userinterface: This application is the “stage direction”, where testplans are defined, results are displayed and analysis is operated. The connection between the script-engine and the user-interface is based on TCP/IP, so both parts may be installed on different machines to decouple both processes. Example Procedure of a Test In the first step the device and its capabilities must be introduced to the test framework. For this, the electronic PICS format (PICS = Proto col Implementation Confor‑ mance Statement) EPICS is used, where all the device capabilities are listed. In the first test, the consistency of the EPICS, this means integrity and accuracy of the EPICS, are checked. The picture shows the results of such an EPICS consistency check. 4.The SQL-database: Directly connected to the userinterface is the database, which contains the full BACnet standard in vari- If the EPICS is correct, the test plan may be generated. The software supports this process by selecting the tests according to the device This allows a wide range of applications far beyond conformance tests. The BACnet test framework with its highly flexible structure is qualified for all kinds of automated tests and allows, the standard or premium edition the definition of own tests, reports or statistics. This makes the BACnet test framework an excellent choice for quality assurance, for long-term tests or similar applications. The results are stored on the basis of OK or ERROR in the database, but may be manually overwritten by adding a comment. The software has been introduced to the testlab WSP-Lab in Stuttgart, Germany within the 4th quarter of 2006. From the beginning of 2007, automated BACnet tests will be available there and at the same time, the software will also be available from MBS. MBS GmbH frank.schubert@mbssoftware.de www.mbs-software.de BACnet France Journal 1 04/07 43 Produits Products Le convertisseur de protocole BAC / IP pour la rénovation de systèmes existants BACnet/IP Protocol Converter for the Renovation of Existing Systems La technologie Internet a de manière signicative élargi le champ des applications des systèmes d’automation du bâtiment, avec les services correspondants offrant notamment une fonctionnalité de gestion accrue. Internet technology significantly broadens the range of application of building automation systems, with the corresponding services providing increased management functionality. Les produits récents DDC/ PLC sont généralement équipés d’un port Ethernet et supportent le protocole de communication BACnet. Cet te innovation a conduit à un décalage à travers l’obtention du process d’information en temps réel directement depuis le contrôleur. L’information de process est facilement accessible depuis n’importe quel lieu distant en utilisant un Intranet sûr ou une connexion réseau et un navigateur Web standard. Un contrôleur DDC/PLC ou PC est utilisé en tant que serveur Web. Les documents sont stockés sur le serveur et sont accessibles où que vous soyez. Cette fonctionnalité représente une réduction considérable des tâches de gestion. Un autre exemple est le transfert automatique des données de process et des alarmes aux utilisateurs et bases de données. La réduction des coûts L’introduction d’une nouvelle technologie signifie en général l’augmentation de la fonctionnalité et du confort. Dans les nouveaux immeubles de bureaux ou lors de rénovations complètes, là où ne ucune situation existante qui nécessite d’être prise en considération, il n’y a aucun problème d’intégration. L’investissement selon le rapport qualité / prix n’est pas un sujet de discussion. Quand un système existant est adapté ou étendu, la si tuation est différente. Les composants existants ne pourraient ne plus être disponibles ou soutenus et le remplacement d’équipement fonctionnant parfaitement devient alors nécessaire. Une perte d’investissement peut être évitée en mettant en application le convertisseur de protocole BACnet IP. Modern DDC/PLC products are generally equipped with an Ethernet connection port and support the BACnet communication protocol. This innovation has led to a shift towards obtaining realtime process information directly from the controller. The process information is easily accessible from any remote location using a secure intranet or network connection and standard web browser. A DDC/PLC controller or PC is used as a web server. Documents are stored on the web server and are accessible from any location. This functionality means a significant reduction in management tasks. Another example is the automatic transfer of process data and alarms to users and databases. Reduction of costs The introduction of new technology usually means increased functionality and comfort. In new buildings or complete renovations, where there is no existing situation that has to be worked around, there are no integration problems. The investment, at a given price/quality ratio, is not a point of discussion. When an existing system is adapted or expanded, the situation is different. Existing components might no longer be available or supported and the early replacement of often perfectly functioning equipment becomes necessary. A loss of capital investment can be avoided by implementing the BACnet IP protocol converter. Le convertisseur de protocole BACnet/IP. BACnet/IP protocol converter. Regel Partners B.V. g.dekoning@regelpartners.nl www.regelpartners.nl 44 BACnet France Journal 1 04/07 Produits Products Contrôleur modulaire E/S librement programmable Freely programmable Modular IO-Controller SysMik présente le contrôleur graphiquement program mable complètement libre ICS-709-B en version 32 Bit pour le système modulaire intégré E/S. Il comprend les interfaces pour les standards BACnet et LonMark®. SysMik introduces the graphically free programmable Controller ICS-709-B in 32 Bit Technology for the Inline Modular IO System. It includes interfaces for BACnet and LonMark® standards. Structure du système. System structure. Le serveur de contrôle ( ControlServer ) intégré ICS-709B dispose des bus pour TP/ FT-10-LON et BACnet/IP via Ethernet 10/100BaseT. Le commutateur intégré permet la connexion de plusieurs contrôleurs ICS de bus intégrés. Le niveau de contrôle optionnel ICS ajuste les E/S pendant la mise en route. La programmation graphi que avec IPOCS IPOCS permet l’application de logiciels basés sur des bibliothèques de fonction. Le logiciel et les points de données sont définis librement à l’intérieur du projet et reliés les uns aux autres. Les points de données des équipements représentent le plan de configuration des bornes d’entrée/sortie intégrées, tandis que les points de données logiciel représentent les propriétés des objets BACnet ou bien les variables réseau des objets LonMark. La communication dirigée par les événements est soutenue par les deux protocoles ( BACnet:COV ). L’interopérabilité conforme aux directives LonMark est garantie ( notamment l’intégration avec les outils LNS ). Ceci vaut également pour la conformité avec le standard BACnet. IPOCS peut simuler les applications, les charger dans le contrôleur et les surveiller/paramétrer en ligne. Le libre choix des bornes entrées/sorties Jusqu’à 63 bornes ana logiques ou digitales par station peuvent être exploitées avec des temps de cycle considérablement inférieurs à 100ms. Une projection LON/BACnet pour 1000 variables réseau est traitée en moins de 5 secondes. Les qua druples relais de puissance ou des interfaces DALI sont disponibles pour le contrôle BACnet de l’éclairage et des bornes S0 pour la gestion de compteurs, permettant ainsi une centralisation efficace des différentes sections à l’intérieur d’une station. ICS avec ses interfaces de communication « natives » et standardisées Contrôleur ICS-709-B. Controller ICS-709-B. pour les systèmes BACnet et LON peut être intégré librement comme composant et aussi utilisé comme passerelle de points de données dans un projet réunissant de multiples fournisseurs car il est indépendant des systèmes de gestion. The Inline ControlServer ICS-709-B includes bus interfaces for TP/FT-10-LON and BACnet/IP via 10/100BaseT-Ethernet. The integrated switch allows for linking of several ICS-Controllers in line bus technology. The optional ICS control level sets hardware IOs during start-up. Graphical programming with IPOCS IPOCS enables the realization of project software based on function libraries. Software and hardware data points are freely defined within the project and linked to each other. Hardware data points represent the map of the inline terminals’ IO configuration, while software data points represent properties in BACnet objects or network variables in LonMark objects. Event driven communication is supported for both protocols (BACnet: COV). The interoperability compliant with the LonMark guidelines is granted (especially the integration with LNS tools). The same applies to the conformity with the BACnet standard. IPOCS can simulate the applications, load them into the controller and monitor/parameterize them online. Free choice of IO terminals Up to 63 analog and digital IO terminals per station can be operated with hardware cycle times considerably below 100ms. A LON/BACnetmapping for 1,000 network variables is processed in less than 5 seconds. Quadruple power relays or DALI interface are available for BACnetlighting control and SO terminals for metering, thus allowing for efficient centralization of different assembly section within one station. ICS with its “native” and standardized communication interfaces for BACnet and LON systems can be freely integrated as component and also be used as data point gateway in multi-vendor projects as it is independent of management systems. SysMik GmbH Dresden sales@sysmik.de www.sysmik.de BACnet France Journal 1 04/07 45 Concentration de toutes les forces dans le but d’une efficacité accrue ❚ transparence de l’information ❚ universalité des marques ❚ intégration des systèmes ❚ accès unique à l’ensemble des informations sur le bâtiment ❚ intégration efficace de tous les fabricants et métiers ❚ solutions BACnet de part en part ❚ respect d’autres standards et normes tels que OPC, EIB, LON, M-Bus, CAN Uniting forces for a single objective: Improved performance ❚ open ❚ manufacturer-neutral ❚ integrative ❚ multiplicité des modules permettant un raccordement direct avec les systèmes d’autres fabricants ❚ uniform access to all building information ❚ effective integration of different manufacturers and trades ❚ integrated BACnet solutions ❚ supports other standards such as: OPC, EIB, LON, M-Bus, CAN ❚ large number of manufacturer modules for direct connection of third-party systems Messner Gebäudetechnik GmbH Weidenweg 13 D-91058 Erlangen (Allemagne) Tél. +49 (0) 91 31 68 70 - 0 Fax +49 (0) 91 31 68 70 - 190 http://www.messner.de Courriel : info@messner.de Produits Products Passerelles et visualisation Gateways and Visualization LOYTEC, un fabricant reconnu de produits d’infrastructure réseau pour les réseaux ANSI/ EIA-709, complète son portefeuille de produits de connectivité BACnet afin de répondre aux besoins croissants du marché pour ce type de solutions. Tous les futurs produits pour BACnet sont basés sur la puce multi protocole LOYTEC/NEC LC3020. LOYTEC, a well known manufacturer of network infrastructure products for ANSI/EIA-709 networks, supplements its portfolio by BACnet connectivity products to meet the increasing demand of the market for such solutions. All upcoming products for BACnet are based on the LOYTEC/NEC multi protocol chip LC3020. L-OPC – Serveur Dédié OPC XML/DA Avec le serveur dédié LOPC -ME200 pour BACnet/IP et les réseaux MS/TP, Loytec offre un serveur OPC avec une approche décentralisée. Le serveur OPC est exécuté sur un dispositif dédié et peut ainsi être connecté directement au niveau des dispositifs terrain ou d’automation. Jusqu’à 1000 points de données par dispositif L-POC peuvent être projetés sur les objets BACnet. Les clients OPC compatibles au standard OPC XML/DA parlent à L-OPC via les services WEB ( SOAP/XML ). L’intégration dans le réseau BACnet est réalisé par l’intermédiaire de BACnet/ IP ou BACnet MS/TP. Un serveur Web intégré peut servir d’hôte aux pages Web avec un contenu actif. L-DALI – BACnet/DALI Passerelle L-DALI fournit 4 canaux DALI indépendants et une possibilité de contrôle indivi duel sur 64 lumières basées DALI par canaux DALI. Comme serveur BACnet ( B-ASC ), L-DALI permet une intégration facile des applications DALI dans l’environnement BACnet ( BACnet/IP ou BACnet MS/TP ). L-GATE – EIA-709/BACnet Passerelle Le L-Gate est une passerelle BACnet ANSI/EIA-709, qui projette les variables réseaux EIA-709 ( NVs ) jusqu’à 500 Objets Serveur BACnet correspondant au standard CEN/TS 15231: 2005. Le L-Gate s’intègre aisément dans les réseaux BACnet/IP ou MS/TP et se connecte à LonMark IP-852 et TP/FT10 canaux. La configuration se fait via l’ANSI/EIA-709. to field or automation level devices. Up to 1000 OPC data points can be mapped to BACnet objects per L-OPC device. OPC clients compliant to the OPC XML/ DA standard talk to the L-OPC through WEB ser vices (SOAP/XML). The integration into the BACnet network is realised via BACnet/ IP or BACnet MS/TP. An integrated web server can host customized Web pages with an active content. L-VIS – Visualisation Le LVIS-ME200 est un panneau tactile librement configurable ( 5,7, 256 couleurs ) pour les réseaux BACnet. Il peut supporter jusqu’à 500 Objets Serveur BACnet. L’intégration dans le réseau BACnet est réalisé via BACnet/IP ou BACnet MS/ TP. Un outil de configuration supporte une prévisualisation WYSIWYG et est inclus dans la livraison – comme pour tous les produits Loytec. L-DALI – BACnet/DALI Gateway L-DALI provides 4 indepen dent DALI channels and individually controls up to 64 DALI-based luminaries per DALI channel. As a BACnet server (B-ASC), L-DALI enables the easy integration of DALI applications into the BACnet environment (BACnet/IP or BACnet MS/TP). L-OPC – Embedded OPC XML/DA Server With the LOPC-ME200 for BACnet/IP and MS/TP networks Loytec offers an OPC Server with a decen tralised approach. The OPC Server is running on the embedded device and can thus be connected directly L-GATE – EIA-709/BACnet Gateway The L-GATE is an ANSI/ EIA-709/BACnet Gateway, which maps EIA-709 network variables (NVs) to up to 500 BACnet Server Objects according the CEN/TS 15231:2005 standard. L-Gate integrates easily into BACnet/ IP or MS/TP networks and connects to LonMark IP-852 and TP/FT-10 channels. The configuration is done through the ANSI/EIA-709 side. Les produits BACnet de LOYTEC dans le réseau. BACnet products of LOYTEC in the network. L-VIS – Visualization The LVIS-ME200 is a freely configurable touch panel (5.7”, 256 colours) for BACnet networks. Up to 500 BACnet Server Objects are supported. The integration into a BACnet network is funded by BACnet/IP or BACnet MS/TP. A confi guration tool supports a WYSIWYG preview and is – as for all Loytec products – included in the delivery. LOYTEC electronics GmbH sales@loytec.com www.loytec.com BACnet France Journal 1 04/07 47 BACnet Interest Group Europe Les nouveaux membres New Members Cylon Controls Cylon Controls fournit des solutions intelligentes de gestion de l’énergie pour les bâtiments. Fondée en 1985, Cylon est maintenant l’un des plus grands fabricants privé de systèmes de contrôle de bâtiment d’Europe et poursuit son développement à l’échelle mondiale. Avec la solution UnitronUC32, Cylon a fournit la techno logie inaugurale UnitPut™ et continue actuellement de la développer en termes d’innovation et de réponse aux exigences du client. Cylon s’est engagé aux normes ouvertes et fournit le support BACnet client et serveur dans son Unitron UC32. En tant que fournisseur indépendant, la philo sophie « Go-to-Market » de Cylon est basée uniquement Ralph Lammers / John Fallon Tel. +49-4171-68 638 info@cylon.com www.cylon.com sur le travail conjoint avec des partenaires reconnus, intégrateurs de système, ce qui assure la compétitivité du service et la faisabilité pour tous les projets, petits ou grands. Cylon Controls provide smart energy control solutions for buildings. Founded in 1985, Cylon is now one of largest independent manufacturer of building control systems in Europe and continues 48 BACnet France Journal 1 04/07 to grow worldwide. With the UnitronUC32 solution Cylon delivered the groundbreaking UniPut™ technology and today continues to lead in terms of innovation and responsiveness to customer requirements. Cylon is committed to open standards and provides BACnet client and server support in UnitronUC32. As the independent supplier Cylon’s go-to-market philosophy is based solely on working through approved system integrator partners which ensures competitive service and support for all projects big or small. Hieronymus SicherheitsSystemhaus GmbH Hieronymus Sicherheits-Systemhaus GmbH est un producteur indépendant de sys tèmes domestiques, certifié DIN EN ISO 900, qui est spécialisé dans les services de consulting, des systèmes de planification, la réalisa tion et la maintenance de solutions appropriées un matieu sécurité du bâtiment. Un concept intégré complet allant de l’analyse du risque et de l’endommagement jusqu’aux services de planification, l’utilisation de différentes technologies, le ser vice et la maintenance ainsi qu’une main d’œuvre quali fiée et efficace pendant la Klaus Hieronymus Tel. +49-69-5050280-0 info@hg.ag www.hieronymus-sicherheit.de Nouveaux membres New Members Association BACnet France phase d’exploitation est la base de notre travail. Nous nommons notre solution : La Gestion Intégrée de la Sécurité ( Integrated Security Management ). La techno logie et le logiciel BACnet sont une base importante de notre philosophie, notamment en matière de services de planification offerts à nos clients internationaux et aux développeurs de projets. Hieronymus Sicherheits-Systemhaus GmbH is a producer-independent system house, certified according to DIN EN ISO 9001, which specializes in consulting services, and the systemwide planning, realization and support of security-relevant solutions for building security. An integrated total concept from risk and endangerment analysis to planning services, employment of different technologies, service & support, and effective handling during the operating phase is the basis of our work. We call it Integrated Security Management or ISM. BACnet capable technology and software are an important basis of our thinking, in particular with planning services for our major international customers and project developers. primion Technology AG Avec plus de 4000 clients à travers le monde, primion Technology AG est l’un des leaders du marché des fournisseurs de système dans le champ d’application des solutions de gestion intégrée de sécurité, la chronologie et la gestion du contrôle d’accès. Nos 20 filiales européennes et 25 partenaires répartis dans le monde entier nous permettent d’offrir une qua lité de service optimale au client. BACnet, le standard international et protocole de communication de données reconnu dans le secteur de l’automation du bâtiment et du contrôle/commande de réseaux, ISO 16484, offre également l’interopérabilité pour la technologie vouée à la sécurité. En tant que fournisseur et revendeur, pri mion sera capable d’intégrer le standard BACnet dans une multitude d’applications. With over 4,000 customers Roland Schmider Tel. +49-7573-952-548 schmider@primion.de www.primion.de worldwide, primion Technology AG is one of the leading system providers in the field of integrated security management, time recording and access control management. Our 20 European branches and 25 system partners worldwide mean that we can offer optimum customer service. BACnet, the global standard data communi- cation protocol for building automation and control networks, ISO 16484, also supports interoperability in security technology. As a groundbreaking one-stop-shop provider, primion will be able to integrate the BACnet global standard in a multitude of ways. Wizcon Systems Wizon Systems, basé en France près de Lyon, est un fournisseur mondial majeur de solutions et services aux entreprises d’automation sans fil ( Wireless Enterprise Automation ) et du logiciel Web-enabled SCADA. De puis 1988, Wizcon Super visor est une solution de contrôle et d’information complète basée sur Internet utilisée dans l’automation du bâtiment, de grandes infrastructures et sur autres marchés de l’automation. Plus de 50 000 licences Wizcon surveillent et gèrent pro-activement des process dans le monde entier. Wizcon offre des équipements de gestion M2M innovants et puissants. En tant que logiciel indépendant avec limplémentation BACnet totale ( PICS ), Wizcon fait de l’intégration complexe de BACnet, un véritable jeu d’enfant. Emmanuel Vitrac Tel. +33-4 72 47 98 98 evitrac@wizcon.com www.wizcon.com Wizcon Systems, based near Lyon in France, is a leading global provider of Webenabled SCADA software and Wireless Enterprise Automation solutions and ser vices. Since 1988, Wizcon Supervisor is a complete Internet-based solution for control and information used in building automation, large Infrastructures, and other automation markets. More than 50,000 Wizcon licen ses proactively monitor and manage processes around the world. Wizcon offers innovative and powerful M2M asset management features. As the only independent software with full BACnet implementation (PICS), Wizcon makes complex BACnet integration easy. Association BACnet France Les entreprises qui soutiennent le Standard BACnet en France sont invitées à devenir membre de l’Association BACnet France. Contact: Association BACnet France Maguy de Mercurio Tel. +49 231 42 78 67 57 mercurio@mardirect.de BACnet France Journal 1 04/07 49 Devenez membre de BACnet France Become a Member of BACnet France Groupe d’intérêt français pour le système d’automation ouvert de bâtiments avec BACnet® French interest group for open building automation systems with BACnet® Association BACnet France Sept raisons de devenir membre : Seven reasons for becoming a member: 1.Réseau 1.Network Profitez du réseau de contacts BACnet pour être en lien direct avec les exploitants et les investisseurs, les prescripteurs et fournisseurs, les vendeurs, les ingénieurs et intégrateurs de systèmes. Soyez connecté(e) à BACnet en Europe, en Amérique du Nord, en Australie et en Asie. Partagez vos expériences avec les autres membres des groupes de travail lors de rencontres dédiées, de salons ou bien encore via nos communautés sur Internet. 2.Un podium pour vos produits et projets Avec notre BACnet France Journal nous vous offrons une plate-forme idéale depuis votre entreprise pour la diffusion des dernières informations relatives à BACnet et au développement de son standard. Parlez aux autres de votre société, de vos références. Partagez de vos informations. Chaque nouveau membre se présente via une chronique résumant son profil. Take advantage of the BACnet network of French contacts to get in touch with operators and investors, planners and suppliers, system vendors, plant engineers and system integrators in France! Get connected with the BACnet Interest Group in Europe, North America, Australia, Asia and the Middle East! Exchange experiences with others in the marketing group and general meetings, at exhibitions and in our mail communities. 2.A podium for products and projects With our BACnet France Journal , we offer a platform for spreading the latest BACnet news from your company for the development of the BACnet Standard. Tell others about your company and your BACnet products and present your reference projects. New members introduce themselves with a short company profile. 3.A reference for your clients 3.Une référence pour vos clients En tant que membre de BACnet France, vous êtes partenaire BACnet reconnu(e) et qualifié(e). As a BACnet France member, you will present yourself to your clients as a qualified BACnet partner. 4.First hand information 4.Des informations de première main Soyez assuré(e) d’être le (la) premier(e) informé(e) des derniers développements BACnet lors de la conception de vos produits. BACnet France est en contact étroit et permanent avec le BIG-EU et informe ses membres des innovations relatives au standard BACnet. Make sure that you are the first to know about the latest BACnet developments when designing your products. BACnet France is in close contact with the BIG-EU and informs its members about innovations to the BACnet Standard. 5.Develop the BACnet ISO Standard 5.Développez le standard ISO BACnet Nous participons au développement du standard ISO BACnet et nous assurons que les requêtes de nos membres soient entendues. Les membres sont invités à apporter leurs idées pour le développement via le BACnet Committee SSPC 135 of ASHRAE et à partager leurs expériences. We participate in the development of the BACnet ISO Standard and make sure that the requests of our members are heard. Members are invited for input which is given via the BIG-EU to the BACnet Committee SSPC 135 of the ASHRAE and to share their experiences. 6.Participation in French BACnet marketing 6.Participation aux événements BACnet Prenez place dans la Communauté BACnet lors d’événements inter nationaux majeurs tels que le Forum BACnet Paris en octobre 2007 ou bien encore lors d’expositions 7.Siège Si vous désirez en savoir plus sur BACnet France et ses services, n’hésitez pas à nous contacter au siège et remplissez le coupon ci-dessous. Take part in our community event such as the BACnet Forum, BACnet exhibitions and common press-work. 7.Head Office If you require any further information about BACnet France and its services, please do not hesitate to contact our French speaking Head Office. Oui, je suis intéressé(e) par les services de BACnet France. Je souhaite recevoir de plus amples informations concernant les formalités d’adhésion. / I am interested in the BIG-EU’s services. Please send me further information about becoming a member. Nom/Name ............................................................................... Pays/Country ............................................................................. Entreprise/Company .................................................................. E-Mail . ...................................................................................... N°, rue/Street No ....................................................................... Tel. ............................................................................................ Code Postal/City/town sort/post code ....................................... .................................................................................................. Date, signature/Date, signature Remplissez ce formulaire et faxez le au numéro suivant : / Please copy this page and fax it to: +49-2 31-42 78 67 32 Nouveaux membres New Members DeTelmmobilien devient membre du BIG-EU DeTeImmobilien becomes BIG-EU member « L’application et l’état d’avancement du standard BACnet sont en lien direct avec les intérêts de DeTelmmobilien » a déclaré le directeur Wilfried Schmahl. “The application and advancement of the BACnet standard are in the direct interest of DeTeImmobilien”, declared managing director Wilfried Schmahl. DeTelmmobilien est devenu membre du BIG-EU, le BACnet Interest Group Europe. Le fournisseur allemand de services allemand de Facility Management l’a intégré en tant que 4eme partenaire aux côtés d’Honeywell, Johnson Controls et Siemens Building Technologies. Avec ce développement, BACnet est donc substantiellement promu pour la première fois par un utilisateur. Le Président du BIG-EU, Volker Roehl a tenu à préciser : « Le standard international pour l’automation du bâtiment est désormais plus encore orienté vers la réponse aux besoins de l’utilisateur. » Le nombre de membres du BIG-EU a grossi pour atteindre un nombre à deux chiffres. Après la standardisation mondiale ( ISO 16484-5 ), les fabricants de système, les intégrateurs, les intégrateurs système en particulier, suivent le standard ouvert. Les utilisateurs finaux sont maintenant représentés par DeTelmmobilien. Wilfried Schmahl, directeur managé rial de la branche FM de DeTelmmobilien nous expli- que : « Nos intérets directs sont à relier à l’application et au développement du standard BACnet, afin d’être capables de fonctionner plus efficacement et de superviser les équipements techniques directement dans les bâtiments de nos clients. » Volker Roehl, autrefois aux commandes de Johnson Controls a pris ses fonctions en novembre 2006 au sein du département Communication et Gestion de crise de DeTelmmobilien. Le comité exécutif et de direction du BIG-EU l’ont accueilli les bras ouverts et soutenu dans sa prise de fonction en tant que Président du BIG-EU. Les membres ont unanimement salué l’arrivée et l’adhésion de Detelmmobilien au sein du BIG-EU. En tant que fournisseur de services, DeTelmmobilien sait quels sont les avanta ges du producteur d’un stan dard de communication indépendant tels que le portefeuille de services couvre la technique, l’infrastructure, le facility management en complément d’une gestion commerciale d’état. DeTeImmobilien has become a member of the BACnet Interest Group Europe (BIG-EU). Germanys largest facility management service provider steps in as the fourth sponsoring member of the BIG-EU alongside Honeywell, Johnson Controls and Siemens Building Technologies. With this development, BACnet is also substantially promoted by a user for the first time. BIG-EU president Volker Roehl stated: “The world standard for building automation has now become even more strongly oriented to the needs of the user.” The number of BIG-EU members has now grown to double figures. After the world-wide standardisation (ISO 16484-5), system manu facturers, planners and system integrators in particularly are following the open standard. End-users are now also represented by DeTeImmobilien. Wilfried Schmahl, managing director of Facility Management at DeTeImmobilien explains: “Our direct interests are in the application and advancement of the BACnet standard, in order to be able to more efficiently operate and supervise the technical equipment in the buildings of our customers.” Volker Roehl, formerly with Johnson Controls, takes over the leadership of the Communications and Fault Management department at DeTeImmobilien starting from November 2006. The executive committee and advisory board of the BIG-EU support him in his new position as a president of the BIG-EU. The members unanimously welcomed the joining of DeTeImmobilien. As a service providers of real estate DeTeImmobilien knows the advantages of the producer-independent com‑ munication standard as the service portfolio covers technical and infrastructure facility management in addition to commercial real estate management. Volker Röhl, Président du BIG-EU, est passé à DeTeImmobilien. Volker Röhl, the president of BIG-EU joined DeTeImmobilien. BACnet France Journal 1 04/07 51 BACnet Interest Group Europe Comment BACnet répond aux dernières exigences technologiques et du marché How BACnet meets the latest market and technological demands Les systèmes BACnet sont programmés pour le futur. Le standard BACnet , ISO 16484-5, est en développement permanent afin d’être toujours en phase avec les exigences technologiques et la demande du marché. Ceci est la responsabilité de l’ASHRAE, l’association américaine des ingénieurs CVC et de son comité, le comité SSPC 135. Les propositions européennes sont quant à elles ajoutées par le BIG-EU ( BACnet Interest Group Europe ). BACnet systems are programmed for the future. The BACnet standard, ISO 16484-5, is being constantly developed to keep pace with the latest market and technological demands. This is the responsibility of the “SSPC 135” standards committee of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). European proposals are added by the BACnet Interest Group Europe. BACnet offre des possibilités toujours croissantes pour l’intégration dans les systèmes d’automation du bâtiment, particulièrement dans le domaine de l’ingénierie de sécurité. Un des cercles de travail du comité des normes travaille sur les questions des systèmes de contrôle d’accès ou bien encore la vidéo surveillance. Addenda au standard Toute modification portée au standard doit suivre une procédure bien spécifique avant d’être acceptée comme partie du standard. Les demandes de changements peuvent être effectués directe ment via le Groupe de Travail Technologie qui est une des parties intégrantes du BIG-EU. Les contributions marquantes sont alors envo yées au comité des normes qui prépare un ajout de document au standard. Puis cet addenda est alors rendu public. A partir de là, les utilisateurs BACnet du monde entier sont consultés pour nous apporter leurs commentaires sur ce dernier. Et c’est seulement une fois que tous les suggestions et changements importants ont été intégrés que l’addenda est publié en tant qu’extension officielle du standard BACnet. Les offreurs peuvent seulement faire référence au supplément quand la revue publique est terminée et l’addenda est publié sur le site Internet de l’ASHRAE ( www.ashrae. org/technology/page/132/ ) sous le nom « d’addenda au standard ». Jusqu’ici il y a encore la possibilité de faire des changements substantiels à la version de l’addenda. Examen public Le standard BACnet 1352004 peut être obtenu auprès des éditeurs agrées ou directement via l’ASHRAE. Les addenda sont disponibles sur les sites Internet du BIG-EU, www.big-eu.org et du comité des standards, www.bacnet.org . Les docu ments justificatifs peuvent également être trouvés sur le site du BIG-EU. Les plus populaires sont les directives VDI-TGA/BIG-EU guidelines, offres écrites pour les systèmes intéropérables d’automation du bâtiment et les manuels d’implantation des systèmes BACnet. 52 BACnet France Journal 1 04/07 Il y a cinq actuellement cinq révisions pour l’examen public.Les technologies de chif‑ frage et d’authentification assurent la communication réseau sécurisée ( Addenda g ). Les nouveaux objets BACnet pour le contrôle d’accès accroissent la protection et la sécurité ( Addenda F ). Après la réception de 53 commentaires, les services Web BACnet sont désormais passés en seconde lecture publique ( Addenda c ). Le contrôle de chargement suggéré est également passé en seconde lecture ( addenda e ). Les évolutions permanentes Même après ces extensions, il y a toujours matière à faire évoluer le standard BACnet. Les définitions pour l’intégration de moteurs de contrôle pour l’utilisation des nouvelles technologies IP et le support des systèmes d’éclairage sont actuellement dans les mains du comité et en attente. BACnet travaille sans compter sur les systèmes d’application fonctionnelle. La planification de zone indépendamment du fabricant, la gestion d’énergie et les applications industrielles sont en passe d’être intégrées. BACnet offers ever increasing possibilities for integra ting building automation systems, particularly in the area of safety engineering. One of the task groups in the standards committee is working on access control systems, another on video surveillance. Addenda to the Standard Any required changes to the standard have to go through a specified procedure before being accepted as part of the standard. Requests for chan ges can be made directly to the Working Group Technology which is part of the BIG-EU. Significant contributions are then sent to the standards committee which prepares an addendum to the standard. The draft addendum then goes for public review. At this stage, BACnet users around the world are asked to give their comments. Only once all of the relevant suggestions and changes have been incorporated is the addendum published as an official extension of the BACnet standard. Tenders may only refer to the addendum when the public review process is finished and when it has been published on the ASHRAE website (www. ashrae.org/technology/ page/132/) as a “standard addendum“. Until then, there are still likely to be substan tial changes to the draft addendum. BACnet Interest Group Europe Public Review The BACnet Standard 1352004 can be obtained from appropriate publishers or directly from ASHRAE. The addenda are available on the websites of the BIG-EU www.big-eu.org and the standards committee www. bacnet.org. Supporting do cuments can also be found on the BIG-EU website. Most popular are the VDI-TGA/ BIG-EU guidelines on writ- ing tenders for interoperable building automation systems and the manual on implementing BACnet systems. There are currently five revisions for public review. Encryption and authentication technologies ensure secure network communica tion (Addendum g). New BACnet objects for access control increase protection and security (Addendum f). Addenda to the Effective Standard BACnet-2004 Addendum 135-2004a (This addendum is final and was approved for publication by the ASHRAE Board of Directors and by the American National Standards Institute on February 10, 2005.) 1. Revise Life Safety Point and Life Safety Zone objects to modify their behaviour when placed out of service Addendum 135-2004b (This document contains only independent substantive changes made to the first public review draft and must be reviewed with that document. The SSPC is currently responding to comments received.) 1. Add a new Event Log object type 2. Add a new Global Group object type 3. Add a new Trend Log Multiple object type 4. Harmonize the Trend Log object with the new Event Log and Trend Log Multiple objects 5. Define a means for a device to provide a notification that it has restarted 6. Define a means to configure a device to periodically send time synchronization messages 7. Extend the number of character sets supported 8. Enable devices other than alarm recipients to acknowledge alarms 9. Allow MS/TP BACnet Data Expecting Reply frames to be broadcast 10. Revise the Clause 5 state machines to handle slow servers 11. Add new Error Codes and specify usage Addendum 135-2004c (This addendum is final and was approved for publication by the ASHRAE Board of Directors September 29, 2006 and by the American National Standards Institute on October 2, 2006.) 1. Adding BACnet/WS web services interface After receiving 53 comments, the BACnet web services are now in their second public review (Addendum c). The suggested load control is also in its second review (Addendum e). Continued Extensions Even after these extensions there is still plenty of potential for the continued growth of the BACnet standard. Definitions for incorporating control drives for using new IP technologies and for supporting lighting systems are currently with the standards committee and are pending. BACnet is increasingly working on operational application systems. Manufacturer independent room layout planning, energy management and industrial applications are being integrated. Addendum 135-2004d (This addendum is final and was approved for publication by the ASHRAE Board of Directors June 29, 2006 and by the American National Standards Institute on June 30, 2006.) 1. Add a new Load Control object type 2. Add a new Structured View object type 3. Allow acknowledgement of unseen TO-OFFNORMAL event notifications 4. Relax the Private Transfer and Text Message BIBB requirements 5. Exclude LIFE_SAFETY and BUFFER_READY notifications from the Alarm Notifications BIBBs 6. Establish the minimum requirements for a BACnet device with an application layer 7. Remove the requirement for the DM-DOB-A BIBB from the B-OWS and B-BC device profiles 8. Relax mandated values for APDU timeouts and retries when configurable, and change default values 9. Fix EventCount handling error in MS/TP Master Node State Machine 10. Permit routers to use a local network number in Device_Address_Binding 11. Identify conditionally writable properties 12. Errors with classes SECURITY or SERVICES mean the service is not executed at all 13. Specify Error returns for the AcknowledgeAlarm service Addendum 135-2004e (This document contains only independent substantive changes made to the first public review draft and must be reviewed with that document. The second public review ended May 1, 2006 and the SSPC is currently responding to comments received.) 1. Add a new Load Control object type Addendum 135-2004f (The first public review ended May 1, 2006 and the SSPC is currently responding to comments received.) 1. Add a new Access Door object type Addendum 135-2004g (The first public review ended May 1, 2006 and the SSPC is currently responding to comments received.) 1. Revise Clause 24 to add new network features Source: ASHRAE SSPC 135 BACnet France Journal 1 04/07 53 BACnet Interest Group Europe Le calendrier BACnet − Calendar of Events Date Lieu – Location Evénement – Event Personne à contacter – Information 2007 11.06.2007 Zurich, CH BIG-EU AB Meeting Prof. Peter Fischer, Fachhochschule Dortmund, D, fischer@fh-dortmund.de 12.06.2007 Zurich, CH BACnet Forum Zurich Britta von Helden, MarDirect GbR, vonhelden@mardirect.de 12.06.2007 Zurich, CH BIG-EU General Meeting Prof. Peter Fischer, Fachhochschule Dortmund, D, fischer@fh-dortmund.de 13.06.2007 Zurich, CH BIG-EU WG-M Meeting Christian Müller, Honeywell GmbH, Offenbach, D, christian.mueller@honeywell.com 13.06.2007 Zurich, CH BIG-EU WG-T Meeting René Quirighetti, Siemens Building Technologies Ltd., Zug, CH, rene.quirighetti@siemens.com Octobre 2007 Paris, F BACnet Forum Paris Maguy de Mercurio, MarDirect GbR, mercurio@mardirect.de 29.-30.11.2007 Krefeld, D BIG-EU/VDI-Training: Gebäudeautomation mit BACnet Frank Schubert, MBS GmbH, Krefeld, D, frank.schubert@mbs-software.de Hans R. Kranz, HAK-Ingenieurberatung Haustechnik Automa tion Kranz, Forst, D, hans.kranz@vdi.de avis Stockholm, S BACnet Forum Stockholm Carolin Seithel, MarDirect GbR, Dortmund, D, seithel@mardirect.de avis Amsterdam, NL BACnet Forum Amsterdam Britta von Helden, MarDirect GbR, Dortmund, D, vonhelden@mardirect.de avis London, GB BACnet Forum London Britta von Helden, MarDirect GbR, Dortmund, D, vonhelden@mardirect.de 05.-08.02.2008 Paris, F BACnet Forum at inter clima + elec Maguy de Mercurio, MarDirect GbR, mercurio@mardirect.de 06.-11.04.2008 Frankfurt/M., D Light+Building 2008 Jochen Willems, MarDirect GbR, willems@mardirect.de 2008 BACnet Test Framework Le groupe d’intérêt européen BACnet présente un nouveau logiciel pour des tests de conformité automatisés. Le « BACnet Test Framework » de l’entreprise de logiciels MBS GmbH a été livré lors de l’exposition ISH de Francfort qui s’est déroulée du 6 au 10 mars dernier. Jusqu’à présent, une série de tests manuels contraignants était nécessaire aux produits BACnet pour l’obtention de la certificaLe Président du BIG-EU Volker Röhl a reçu l’outil pour les tests automatiques de confor mité des mains du PDG de l’entreprise de logiciel MBS Martin Brust-Theil. Les membres du directoire du BIG-EU, Gijs de Koning, Roger Braun, et Hans Werner Koch ( de gauche à droite ) parlent d’un moment historique. The President of the BIG-EU, Volker Röhl (l.), accepted the automated conformity testing solution from Martin Brust-Theiß, Director of MBS. The BIG-EU Board of Directors, Gijs de Koning, Roger Braun and Hans-Werner Koch (from right to left) said that it was an historical moment. 54 BACnet France Journal 1 04/07 tion de conformité, le Logo BTL, si prisé. L’examen de conformité aux normes DIN EN ISO 16484-6 sera ainsi plus rapide, plus simple et moins coûteux. The BACnet Interest Group Europe (BIG-EU) presents a software solution for automated conformity testing. The “BACnet Test Framework” was presented by MBS Software GmbH at the ISH in Frankfurt (6-10/03/2007). Until now, BACnet products could only be awarded the BTL Logo after a tedious manual test procedure. The new automated solution is a quicker, simpler and more cost-effective way to certify devices in accordance with DIN EN ISO 16484-6. BACnet Force d’Avenir – Automation efficace du bâtiment en France » Planification » Rentabilité » Applications Annonce : Octobre 200, Paris www.bacnetforum.org « Depuis que BACnet est conforme à la norme ISOStandard et à la norme européenne, son succès va grandissant. Entre-temps ce sont des dizaines de milliers d’installations BACnet performantes, qui sont réparties sur toute la planète. » H. Michael Newman Fondateur du Comité de Standardisation BACnet SSPC-135 Préinscription Par e-mail : mercurio@mardirect.de Par fax : +49-2 31-42 78 67 32 Par Internet : www.bacnetforum.org Responsable Association BACnet France, Paris Organisateur et Secrétariat MarDirect Droste-Hülshoff-Straße 1 D-44141 Dortmund Contact Maguy de Mercurio mercurio@mardirect.de Tel. +49 231 42786731 “homo mensura” Man is the measure of all things L’homme est la mesure ... that is also true for our products. We offer the latest building automation technology – with easy operation and extensive application. This is literally “tangible” with our DDC4200 central unit, which is equipped with native BACnet and comes with easy and intuitive touchscreen operation. The Neutrino-GLT building automation system is our interface between the human operator and the control technology. With individually generated site images and many other functions, even complex systems can be monitored and controlled. … c’est aussi vrai pour nos produits. Nous vous offrons des solutions techniques les plus modernes pour l’automation des bâtiments – un confort d’utilisation optimal pour une application le plus simple. L’écran tactile de notre centrale DDC4200 qui est native BACnet, vous permet une évolution intuitive en toute aisance. La centrale de supervision GLT avec le logiciel Neutrino est notre interface entre l’homme et la technique. Par des synoptiques d’installations, simples et adaptés, la gestion technique de votre patrimoine vous apportera confort de gestion, sécurité et performance. Kieback&Peter GmbH & Co. KG Tempelhofer Weg 50, 12347 Berlin, Germany Tel.: +49 30 60095-0, Fax: +49 30 60095-164 www.kieback-peter.de, info@kieback-peter.de Kieback&Peter SA Parc des Bellevues, Allée Rosa Luxembourg Bât. Le Wisconsin, 95610 Eragny/Oise, France Tel.: +33 1 343022- 33, Fax: +33 1 343022- 34 www.kieback-peter.fr, info@kieback-peter.fr